Curved Barrel Vault

Transcription

Curved Barrel Vault
SPECIFICATIONS
Lean - to
Bristolite Daylighting Systems brings more than fourty-six years of experience to
monumental skylights and glazing techniques, along with an outstanding reputation for
quality and integrity. Our Engineering and Product Design Department operates with the
most up-to-date equipment in the industry, including Computer Aided Design (CAD) work
stations and competent, experienced personnel. This enables us to provide all needed
services in-house, from consultation and concept through manufacturing and installation.
Our many years of experience mean that we can assist you in every phase of your
project. We will help you choose the design that will best fit your application, select the
proper materials, conduct energy and daylighting performance studies, and do complete
structural and engineering analysis.
Continuing the tradition of quality and innovation, Bristolite Daylighting Systems offers
multiple structural systems to satisfy customer requirements. Our Skypro System can
be used for most custom applications. The Natural Systems incorporate current glazing
technologies in standard vault and ridge type designs. In further response to the building
industry’s increasing requirement for speed and lower cost, we have developed our
SkyQuick system. Designed primarily for smaller applications this system optimizes the
benefits of structural aluminum, minimizes production time, and utilizes only top quality
materials that are used in our other systems.
All of our structural skylight designs feature custom extruded members of architectural
grade aluminum alloys.
Bristolite’s Skylight Design Manual includes structural load charts, available designs
and details, specifications, and glazing information and is available to qualified design
professionals. Please contact our Sales Department to request a copy.
Bristolite’s glazing system is the result of many years of design experience, and
incorporates state-of-the-art technology. In addition to Architectural grade aluminum
Bristolite uses only the finest quality silicone glazing blocks, stainless steel fasteners and
other premium glazing materials per your specifications.
Please contact our sales experts with your next skylight project. Depending on your
project requirements you may also wish to request literature and information on our
SkyQuick custom units which are designed to ship pre-assembled and pre-glazed.
Hip Ridge
2
Barrel Vault Skylights
Ridge (Square Curb)
Norwalk Arts and Sports Complex
Norwalk, California
Ridge (Square Curb)
Ridge (Plumb Curb)
Continuous - Grid Modular
Acrylic Glazed
BARREL VAULTS
Tristar Project
Huntington Beach, California
Lean -
Tri-County Rail Station
Hialeah, Florida
Curved
BarrelCurb)
Vault
Ridge
(Square
Polygon
- Octagon
Ridge
(Plumb
Curb)
Greenhouse - Solarium
Hip Rid
Curved Barrel Vault
CurvedVault
Barrel Vault
Segmented
Quarter
Curved Barrel
Vault
Segmented Barrel Vault
Segmented
Barrel
Vault
Polygon - Octagon
Curved Barrel Vault
Curved Quarter
Vault
3 Gable R
CONTINUOUS & GRID MODULE SKYLIGHTS
Continuous & Grid Module Skylights
4
Children’s Hospital of Orange
Orange, California
TriStar Project
Continuous - Grid Modular
Continuous - Grid Modular
Acrylic Glazed
Grid Modular
Lean - to
Ridge (Square Curb)
Structural Pyramids & Polygons
Bayview
Newport Beach, California
Carson Mall
Ridge (Square Curb)
Ridge (Plumb Curb)
Carson, California
Ridge (Square Curb)
Ridge (Plumb Curb)
Curved Barrel Vault
Polygon - Octagon
Curved Barrel Vault
Polygon - Octagon
Compri Hotel
Southfield, Michigan
Segmented Quarter Vault
Lean
- to Vault
Segmented
Quarter
Segmented
Barrel
Vault
Ridge (Square
Curb)
Segmented Barrel Vault
Ridge (Plumb Curb)
Polygon - Octagon
Polydome
Hip
Ridge
Polydome
Polydome
Pyramid
CurvedPyramid
Barrel Vault
Pyramid
STRUCTURAL PYRAMID & POLYGON
Ridge (Plumb Curb)
Polygon
Polygon - Octagon
5
RIDGELITES & HIP RIDGES
Ridges and Hip Ridges
ontinuous - Grid Modular
Acrylic Glazed
Ridge (Square Curb)
Ridge (Plumb Curb)
Redwood City Police Facility
Redwood City, California
reenhouse - Solarium
Hip Ridge
Curved Barrel Vault
Polygon - Octagon
State Capitol Building
Austin, Texas
Gable Ridge
Curved Quarter Vault
Gable Ridge
Continuous - Grid Modular
Acrylic Glazed
Segmented Quarter Vault
Continuous - Grid Modular
Acrylic Glazed
Lean - to
Single Sloped
Storefront
Ridge (Square Curb)
6
Lean - to
Greenhouse - Solarium
Ridge (Plumb
Curb)
Ridge
(Plumb Curb)
Hip Ridge
Greenhouse
- Solarium
Segmented Barrel Vault
Ridge (Square Curb)
Ridge
Ridge
(P
Ridge (Square
Lean -Curb)
to
Polydome
Gable
Pyramid
Hip Ridge
Curved Barrel
Vault
Hip Ridge
Curve
Polygo
Continuous - Grid Modular
Acrylic Glazed
Lean - to
Ridge (Square Curb)
Bowsers Museum
Santa Ana, California
Continuous - Grid Modular
Acrylic Glazed
Continuous - Grid Modular
Acrylic Glazed
Greenhouse - Solarium
Lean - to
Hip Ridge
Greenhouse - Solarium
Hip Ridge
Gable Ridge
Greenhouse - Solarium - Solarium
Greenhouse
Curved Quarter Vault
Curved Quarter Vault
le Ridge
Continuous - Grid Modular
Acrylic Glazed
Curved
Quarter Vault
Storefront
Storefront
Lean - to Gable Ridge
Lean - to
Single Sloped
Storefront
L E A N -TO & S I N G L E S L O P E D S K Y L I G H TS
Lean-to and Single Slope Skylights
Ridge (Sq
Lean - to
Ridge (Square Curb)
Curved Barrel Vault
Curved B
Hip Ridge
Curved Barrel Vault
Segmented Quarter Vault
Terasaki Lab
Los Angeles, California
Segmented
Gable Ridge
Segmented Quarter Vault
Ridge (Square Curb)
Ridge (Plum
Single Sloped
Single Sloped
Polydome
7
Po
SPECIFICATIONS
I. SPECIFICATIONS
1.1) SCOPE
A. This Specification authorizes that engineering, materials, fabrication,
installation and warranty of Skylight project will be carried to completion by
one Skylight manufacturer.
1.2) QUALITY ASSURANCE
A. The Skylights will be a product of Bristolite Daylighting Systems.
B. AAMA standards shall be adhered to throughout construction.
C. Work will be performed by qualified, experienced and approved personnel.
1.3) SUBMITTALS
A. Shop Drawings
_________ copies of shop drawings shall be submitted for the architects
approval prior to starting fabrication.
B. Structural Calculations by a registered professional engineer to confirm
compliance with all loading requirements.
C. The skylight manufacturer shall submit for architect’s approval the following
test reports and samples in regard to flush silicone joinery:
1. Test data on adhesion samples of metal and glass tested in accordance
with ASTM-C-794.
2. Compatibility statement that the materials in contact with the sealant
(such as gaskets, spacers, setting blocks) are compatible with the sealant
after 21 days exposure to ultra violet, 2000-4000 (micro watt u.v.
radiation).
3. A statement that the stress on the silicone sealant (per detail), when
exposed to the specified load, does not exceed 20 psi.
4. The skylight manufacturer shall provide the sealant manufacturer shop
drawings showing size of lights, design windload and sealant dimensions
for sealant manufacturer’s evaluation and statement on stress.
5. Where applicable a statement from the supplier of insulating glass that
the units will withstand the specified loads.
1.4) LOADING REQUIREMENTS
A. Aluminum Skylight structures shall be designed for loads prescribed by the
governing building codes. Deflection of rafters will not exceed L/175 of the
rafter span.
1.5) WARRANTY
A. A written warranty will be presented that certifies Skylight(s) shall be free of
defects in design, materials, and construction and will not leak for a period of
____ years from date Skylight is completed.
B. Glazing materials are covered by glazing manufacturer’s standard warranty.
2. PRODUCT
2.1) Manufacturer
A. Skylight shall be manufactured by:
Bristolite Daylighting Systems
401 E. Goetz Avenue,
Santa Ana, California 92707 (714) 540-8950, (800) 854-8618.
2.2) MATERIALS
A. Aluminum supporting members shall have the minimum mechanical
properties of aluminum alloy 6063-T5 or 6063-T6.
B. The actual alloy, temper and thickness shall be determined upon the physical
performance required to conform with requirements of:
a. loading and deflection
b. cross sectional configuration
c. finish 613/861
d. thermal expansion and contraction
C. Formed sheet aluminum shall be 5052-H32
D. Glazing
a. Exterior glazing shall be (Architect to specify thickness and color of glass
or plastic). Safety glass must be specified for all glass applications.
b. Interior glazing shall be (Architect to specify thickness in plastic or glass).
Laminated glass is recommended on all glass lights and heat absorbing
tinted materials cannot be specified.
E. Glazing gaskets shall be silicone, santoprene, or neoprene with the following
specifications:
a. Hardness: 50 ± 5 Durometer Shore A
Tensile Strength: 800
PSI(Min)
Elongation: 300% (Min)
Tear: die B, PSI: 65 (Min)
Color: Black
b. Compression Set: 22 Hours @ 212°F: 20%
c. Heat Aging Characteristics: 70 Hours @ 212°F Hardness Change: +3%
Tensile Change: -10%
Elongation change: -20%
d. Weather Resistance: 1 part ozone per million, 500 hours @ 20%
elongation to show no cracks.
e. Material to have no visual checks, cracks or breaks after tests are
completed.
f. Conformance with AAMA standard SG-I-76.
F. Setting blocks shall be 80 ± Durometer, Black Silicone.
G. Fasteners
a. Fasteners used in construction shall be 300 series stainless
b. Fasteners used to install Skylight to suporting curb shall be cadmium
plated steel unless otherwise specified.
H. Flashing shall be 0.06 (Min) aluminum with finish-matching other components.
I. Finish: Specified by Architect
J. Sealants:
tandard construction joints and all non-structural seals shall be silicone
a. S
sealant applied in accordance with the manufacturer’s recommendation.
b. Structural joints shall be sealed using high performance silicone sealants
applied in accordance with the manufacturer’s recommendation.
2.3) FABRICATION
A. The Skylight(s) shall be constructed with aluminum extrusions of alloy as
specified.
B. In so far as practicable, skylights shall be completely fabricated in
manufacturers shop. Structures that cannot be permanently shop assembled
shall be completely erected in the manufacturer’s shop, marked and
disassembled prior to shipment to the jobsite to insure accurate erection.
C. Rafters designed to provide snap-in installation of glazing gaskets.
D. All rafter caps shall be attached using stainless steel fasteners. Fasteners shall
be located at a maximum distance of 12” on center.
E. All brackets for securing rafters shall be of aluminum and will be welded,
riveted, or bolted in our factory.
F. All welding shall be the Heliarc process.
lass shall be supported with silicone setting blocks in accordance with glass
G. G
manufacturer’s recommendations.
a. Glass shall be separated with spacers at all extrusions.
b. Glass shall not touch any metal component of Skylight.
H. holes shall be provided to drain condensation to the outside.
I. Fastener conceal strips available to cover screws in rafters and purlins
(optional).
3. INSTALLATION
A. The Skylight manufacturer shall be responsible for complete erection and
glazing of the installation.
3.1) INSPECTION
A. The installer shall inspect all mounting surfaces and determine that the area in
design and dimensional agreement, with the approved shop drawings.
B. In the event of error in the substrate, the installer is to bring all deviations to
the attention of the general contractor at once. No further erection work will
proceed until the incorrect work is amended
3.2) SURFACE PREPARATION
A. Aluminum structure of Skylight(s) must not make direct contact with dissimilar
materials.
B. To prevent electrolyte action and corrosion a protective coating must be
provided between dissimilar materials.
See ICC Evaluation Service, Inc. Evaluation Report No. 3177
FLorida Approval #14006-R1
Dade County, Florida NOA nos. 13-1007.05 and 12-0301.03
American Architectural
Manufacturer’s Association
To allow for Bristolite’s continuing policy of product improvements, all specifications
are subject to change without notice.
See ICC Evaluation Service, Inc. ESR-3177 for allowable values and/or conditions of
use concerning material presented in this document. It is subject to re-examination,
revisions and possible cancellation.
CAUTION
Bristolite’s skylights are designed to withstand normal elements
of the weather. They are not designed to withstand human
impact or falling objects. These skylights should not be walked
upon under any circumstances. The owner or designer should
restrict access only to authorized personnel who have been
adequately cautioned as to the location of the skylights and informed of the
warning above, or said owner should provide protective guardrails or screens
around the skylights
For additional technical information and/or daylighting systems
design consultation, contact Bristolite for your specific needs.
CALIFORNIA
401 E. Goetz Avenue, Santa Ana, CA 92707
800.854.8618 • 714.540.8950 • Fax 714.540.5415
TEXAS
100 Metro Drive, Terrell, TX 75160
855.266.1331 • Fax 972.210.4091
[email protected] • www.bristolite.com
LIT-R7