Curved Barrel Vault
Transcription
Curved Barrel Vault
SPECIFICATIONS Lean - to Bristolite Daylighting Systems brings more than fourty-six years of experience to monumental skylights and glazing techniques, along with an outstanding reputation for quality and integrity. Our Engineering and Product Design Department operates with the most up-to-date equipment in the industry, including Computer Aided Design (CAD) work stations and competent, experienced personnel. This enables us to provide all needed services in-house, from consultation and concept through manufacturing and installation. Our many years of experience mean that we can assist you in every phase of your project. We will help you choose the design that will best fit your application, select the proper materials, conduct energy and daylighting performance studies, and do complete structural and engineering analysis. Continuing the tradition of quality and innovation, Bristolite Daylighting Systems offers multiple structural systems to satisfy customer requirements. Our Skypro System can be used for most custom applications. The Natural Systems incorporate current glazing technologies in standard vault and ridge type designs. In further response to the building industry’s increasing requirement for speed and lower cost, we have developed our SkyQuick system. Designed primarily for smaller applications this system optimizes the benefits of structural aluminum, minimizes production time, and utilizes only top quality materials that are used in our other systems. All of our structural skylight designs feature custom extruded members of architectural grade aluminum alloys. Bristolite’s Skylight Design Manual includes structural load charts, available designs and details, specifications, and glazing information and is available to qualified design professionals. Please contact our Sales Department to request a copy. Bristolite’s glazing system is the result of many years of design experience, and incorporates state-of-the-art technology. In addition to Architectural grade aluminum Bristolite uses only the finest quality silicone glazing blocks, stainless steel fasteners and other premium glazing materials per your specifications. Please contact our sales experts with your next skylight project. Depending on your project requirements you may also wish to request literature and information on our SkyQuick custom units which are designed to ship pre-assembled and pre-glazed. Hip Ridge 2 Barrel Vault Skylights Ridge (Square Curb) Norwalk Arts and Sports Complex Norwalk, California Ridge (Square Curb) Ridge (Plumb Curb) Continuous - Grid Modular Acrylic Glazed BARREL VAULTS Tristar Project Huntington Beach, California Lean - Tri-County Rail Station Hialeah, Florida Curved BarrelCurb) Vault Ridge (Square Polygon - Octagon Ridge (Plumb Curb) Greenhouse - Solarium Hip Rid Curved Barrel Vault CurvedVault Barrel Vault Segmented Quarter Curved Barrel Vault Segmented Barrel Vault Segmented Barrel Vault Polygon - Octagon Curved Barrel Vault Curved Quarter Vault 3 Gable R CONTINUOUS & GRID MODULE SKYLIGHTS Continuous & Grid Module Skylights 4 Children’s Hospital of Orange Orange, California TriStar Project Continuous - Grid Modular Continuous - Grid Modular Acrylic Glazed Grid Modular Lean - to Ridge (Square Curb) Structural Pyramids & Polygons Bayview Newport Beach, California Carson Mall Ridge (Square Curb) Ridge (Plumb Curb) Carson, California Ridge (Square Curb) Ridge (Plumb Curb) Curved Barrel Vault Polygon - Octagon Curved Barrel Vault Polygon - Octagon Compri Hotel Southfield, Michigan Segmented Quarter Vault Lean - to Vault Segmented Quarter Segmented Barrel Vault Ridge (Square Curb) Segmented Barrel Vault Ridge (Plumb Curb) Polygon - Octagon Polydome Hip Ridge Polydome Polydome Pyramid CurvedPyramid Barrel Vault Pyramid STRUCTURAL PYRAMID & POLYGON Ridge (Plumb Curb) Polygon Polygon - Octagon 5 RIDGELITES & HIP RIDGES Ridges and Hip Ridges ontinuous - Grid Modular Acrylic Glazed Ridge (Square Curb) Ridge (Plumb Curb) Redwood City Police Facility Redwood City, California reenhouse - Solarium Hip Ridge Curved Barrel Vault Polygon - Octagon State Capitol Building Austin, Texas Gable Ridge Curved Quarter Vault Gable Ridge Continuous - Grid Modular Acrylic Glazed Segmented Quarter Vault Continuous - Grid Modular Acrylic Glazed Lean - to Single Sloped Storefront Ridge (Square Curb) 6 Lean - to Greenhouse - Solarium Ridge (Plumb Curb) Ridge (Plumb Curb) Hip Ridge Greenhouse - Solarium Segmented Barrel Vault Ridge (Square Curb) Ridge Ridge (P Ridge (Square Lean -Curb) to Polydome Gable Pyramid Hip Ridge Curved Barrel Vault Hip Ridge Curve Polygo Continuous - Grid Modular Acrylic Glazed Lean - to Ridge (Square Curb) Bowsers Museum Santa Ana, California Continuous - Grid Modular Acrylic Glazed Continuous - Grid Modular Acrylic Glazed Greenhouse - Solarium Lean - to Hip Ridge Greenhouse - Solarium Hip Ridge Gable Ridge Greenhouse - Solarium - Solarium Greenhouse Curved Quarter Vault Curved Quarter Vault le Ridge Continuous - Grid Modular Acrylic Glazed Curved Quarter Vault Storefront Storefront Lean - to Gable Ridge Lean - to Single Sloped Storefront L E A N -TO & S I N G L E S L O P E D S K Y L I G H TS Lean-to and Single Slope Skylights Ridge (Sq Lean - to Ridge (Square Curb) Curved Barrel Vault Curved B Hip Ridge Curved Barrel Vault Segmented Quarter Vault Terasaki Lab Los Angeles, California Segmented Gable Ridge Segmented Quarter Vault Ridge (Square Curb) Ridge (Plum Single Sloped Single Sloped Polydome 7 Po SPECIFICATIONS I. SPECIFICATIONS 1.1) SCOPE A. This Specification authorizes that engineering, materials, fabrication, installation and warranty of Skylight project will be carried to completion by one Skylight manufacturer. 1.2) QUALITY ASSURANCE A. The Skylights will be a product of Bristolite Daylighting Systems. B. AAMA standards shall be adhered to throughout construction. C. Work will be performed by qualified, experienced and approved personnel. 1.3) SUBMITTALS A. Shop Drawings _________ copies of shop drawings shall be submitted for the architects approval prior to starting fabrication. B. Structural Calculations by a registered professional engineer to confirm compliance with all loading requirements. C. The skylight manufacturer shall submit for architect’s approval the following test reports and samples in regard to flush silicone joinery: 1. Test data on adhesion samples of metal and glass tested in accordance with ASTM-C-794. 2. Compatibility statement that the materials in contact with the sealant (such as gaskets, spacers, setting blocks) are compatible with the sealant after 21 days exposure to ultra violet, 2000-4000 (micro watt u.v. radiation). 3. A statement that the stress on the silicone sealant (per detail), when exposed to the specified load, does not exceed 20 psi. 4. The skylight manufacturer shall provide the sealant manufacturer shop drawings showing size of lights, design windload and sealant dimensions for sealant manufacturer’s evaluation and statement on stress. 5. Where applicable a statement from the supplier of insulating glass that the units will withstand the specified loads. 1.4) LOADING REQUIREMENTS A. Aluminum Skylight structures shall be designed for loads prescribed by the governing building codes. Deflection of rafters will not exceed L/175 of the rafter span. 1.5) WARRANTY A. A written warranty will be presented that certifies Skylight(s) shall be free of defects in design, materials, and construction and will not leak for a period of ____ years from date Skylight is completed. B. Glazing materials are covered by glazing manufacturer’s standard warranty. 2. PRODUCT 2.1) Manufacturer A. Skylight shall be manufactured by: Bristolite Daylighting Systems 401 E. Goetz Avenue, Santa Ana, California 92707 (714) 540-8950, (800) 854-8618. 2.2) MATERIALS A. Aluminum supporting members shall have the minimum mechanical properties of aluminum alloy 6063-T5 or 6063-T6. B. The actual alloy, temper and thickness shall be determined upon the physical performance required to conform with requirements of: a. loading and deflection b. cross sectional configuration c. finish 613/861 d. thermal expansion and contraction C. Formed sheet aluminum shall be 5052-H32 D. Glazing a. Exterior glazing shall be (Architect to specify thickness and color of glass or plastic). Safety glass must be specified for all glass applications. b. Interior glazing shall be (Architect to specify thickness in plastic or glass). Laminated glass is recommended on all glass lights and heat absorbing tinted materials cannot be specified. E. Glazing gaskets shall be silicone, santoprene, or neoprene with the following specifications: a. Hardness: 50 ± 5 Durometer Shore A Tensile Strength: 800 PSI(Min) Elongation: 300% (Min) Tear: die B, PSI: 65 (Min) Color: Black b. Compression Set: 22 Hours @ 212°F: 20% c. Heat Aging Characteristics: 70 Hours @ 212°F Hardness Change: +3% Tensile Change: -10% Elongation change: -20% d. Weather Resistance: 1 part ozone per million, 500 hours @ 20% elongation to show no cracks. e. Material to have no visual checks, cracks or breaks after tests are completed. f. Conformance with AAMA standard SG-I-76. F. Setting blocks shall be 80 ± Durometer, Black Silicone. G. Fasteners a. Fasteners used in construction shall be 300 series stainless b. Fasteners used to install Skylight to suporting curb shall be cadmium plated steel unless otherwise specified. H. Flashing shall be 0.06 (Min) aluminum with finish-matching other components. I. Finish: Specified by Architect J. Sealants: tandard construction joints and all non-structural seals shall be silicone a. S sealant applied in accordance with the manufacturer’s recommendation. b. Structural joints shall be sealed using high performance silicone sealants applied in accordance with the manufacturer’s recommendation. 2.3) FABRICATION A. The Skylight(s) shall be constructed with aluminum extrusions of alloy as specified. B. In so far as practicable, skylights shall be completely fabricated in manufacturers shop. Structures that cannot be permanently shop assembled shall be completely erected in the manufacturer’s shop, marked and disassembled prior to shipment to the jobsite to insure accurate erection. C. Rafters designed to provide snap-in installation of glazing gaskets. D. All rafter caps shall be attached using stainless steel fasteners. Fasteners shall be located at a maximum distance of 12” on center. E. All brackets for securing rafters shall be of aluminum and will be welded, riveted, or bolted in our factory. F. All welding shall be the Heliarc process. lass shall be supported with silicone setting blocks in accordance with glass G. G manufacturer’s recommendations. a. Glass shall be separated with spacers at all extrusions. b. Glass shall not touch any metal component of Skylight. H. holes shall be provided to drain condensation to the outside. I. Fastener conceal strips available to cover screws in rafters and purlins (optional). 3. INSTALLATION A. The Skylight manufacturer shall be responsible for complete erection and glazing of the installation. 3.1) INSPECTION A. The installer shall inspect all mounting surfaces and determine that the area in design and dimensional agreement, with the approved shop drawings. B. In the event of error in the substrate, the installer is to bring all deviations to the attention of the general contractor at once. No further erection work will proceed until the incorrect work is amended 3.2) SURFACE PREPARATION A. Aluminum structure of Skylight(s) must not make direct contact with dissimilar materials. B. To prevent electrolyte action and corrosion a protective coating must be provided between dissimilar materials. See ICC Evaluation Service, Inc. Evaluation Report No. 3177 FLorida Approval #14006-R1 Dade County, Florida NOA nos. 13-1007.05 and 12-0301.03 American Architectural Manufacturer’s Association To allow for Bristolite’s continuing policy of product improvements, all specifications are subject to change without notice. See ICC Evaluation Service, Inc. ESR-3177 for allowable values and/or conditions of use concerning material presented in this document. It is subject to re-examination, revisions and possible cancellation. CAUTION Bristolite’s skylights are designed to withstand normal elements of the weather. They are not designed to withstand human impact or falling objects. These skylights should not be walked upon under any circumstances. The owner or designer should restrict access only to authorized personnel who have been adequately cautioned as to the location of the skylights and informed of the warning above, or said owner should provide protective guardrails or screens around the skylights For additional technical information and/or daylighting systems design consultation, contact Bristolite for your specific needs. CALIFORNIA 401 E. Goetz Avenue, Santa Ana, CA 92707 800.854.8618 • 714.540.8950 • Fax 714.540.5415 TEXAS 100 Metro Drive, Terrell, TX 75160 855.266.1331 • Fax 972.210.4091 [email protected] • www.bristolite.com LIT-R7