Current Status of Audiometric Device Calibration in China
Transcription
Current Status of Audiometric Device Calibration in China
Current Status of Audiometric Device Calibration in China ZHONG Bo National Institute of Metrology, China [email protected] Contents 1 Significance of Calibration 2 International Standards 3 Traceability System 4 Pure-tone Audiometer Calibration 5 Impedance Audiometer Calibration 6 Hearing Screening Equipment Calibration 2 1 Significance of Calibration Hearing is one of the most important way to obtain information for human being As people pay more attention to hearing health, a lot of equipment are used for audiometry, hearing disease diagnosis and recovery. Pure-tone Audiometer Aural Acoustic Impedance Audiometer Hearing Equipment Hearing Test Oto-Acoustic Emission Audiometer (OAE) Auditory Brainstem Response Audiometer (ABR) Hearing Aids Hearing Improving Hearing Protector Hearing Protection Hearing metrology aims to make the measurement accurate and unified. 3 1 Significance of Calibration Pure-tone Audiometer Normal Ear Hearing Loss Ear 4 1 Significance of Calibration Aural Acoustic Impedance Audiometer Normal Ear Abnormal Ear 5 1 Significance of Calibration Oto-Acoustic Emission Audiometer TEOAE DPOAE 6 1 Significance of Calibration Auditory Brainstem Response Audiometer 7 1 Significance of Calibration Inaccurate device causes incorrect test results: If actual stimulus intensity is smaller than standard value, the measured hearing threshold will be higher, make incorrect conclusion that the ear is “not good”; If actual stimulus intensity bigger than standard value, the measured hearing threshold will be lower, make incorrect conclusion that the ear is “good”; Factors to cause inaccurate device: Device’s Electrical performance changes, for example the signal generator drifts because of electrical components on circuit board. Transducers’s performance changes Sensitivity (or Conversion efficiency); Frequency Response; Audiometers need to be calibrated regularly!!! 8 Contents 1 Significance of Calibration 2 International Standards 3 Traceability System 4 Pure-tone Audiometer Calibration 5 Impedance Audiometer Calibration 6 Hearing Screening Equipment Calibration 9 2 International Standards The hearing standards mainly come from two international organizations: IEC and ISO. Hearing Standards Classification: Audiometric Equipments; Calibration Device for Audiometric Equipments; Hearing Threshold; Audiometric Test Methods Hearing Aids; Hearing Protector; 2 International Standards Audiometric Equipments 2 International Standards Calibration Device for Audiometric Equipments 2 International Standards Hearing Threshold 2 International Standards Audiometric Test Methods 2 International Standards Hearing Aids (1) 2 International Standards Hearing Aids (2) 2 International Standards Hearing Protectors 2 International Standards According to these international standards, we make our national standards and also calibration specifications. For Example: IEC 60645-1 Electroacoustics - Audiometric Equipment: Part 1 Pure-tone audiometers (International Standard) GB/T 7341.1 Electroacoustics - Audiometric Equipment- Part 1: Pure-tone audiometers (National Standard) JJG 388 Verification Regulation of pure-tone audiometers (Calibration Specification) Contents 1 Significance of Calibration 2 International Standards 3 Traceability System 4 Pure-tone Audiometer Calibration 5 Impedance Audiometer Calibration 6 Hearing Screening Equipment Calibration 19 3 Traceability System Verification Scheme of Measuring Instruments for Audiometry 20 3 Traceability System Primary Calibration System for LS Microphone Primary Calibration System for Accelerometer Zero Level Standards of Air Conduction (Ear Simulator) Zero Level Standards of Bone Conduction (Artificial Mastoid) Imdedance Audiometer NIM Provincial Metrology Certer Calibration System for Audiometer Pure-tone Audiometer NIM Speech Audiometer 3 Traceability System Zero Level of Air Conduction 50 Hz ~10000 Hz U=0.7 dB (k=2) Zero Level of Bone Conduction 250 Hz ~ 8000 Hz U=1.0 dB (k=2) Zero level standards of air conduction and bone conduction 3 Traceability System Calibration System for Audiometer Air-Conduction 125Hz~8kHz U=1.5dB (k=2) Bone-Conduction 250Hz~8kHz U=2.5dB (k=2) Contents 1 Significance of Calibration 2 International Standards 3 Traceability System 4 Pure-tone Audiometer Calibration 5 Impedance Audiometer Calibration 6 Hearing Screening Equipment Calibration 24 4 Pure-tone Audiometer Calibration Audiometer Audiometer Earphone Vibrator Ear Simulator Sound Analyzer Artificial Mastoid Sound Analyzer 4 Pure-tone Audiometer Calibration JJG 388 Verification Regulation of pure-tone audiometers Bone Conduction Zero Level Distortion Zero Level Air Conduction Distortion Linearity Narrow Band Noise Frequency 4 Pure-tone Audiometer Calibration Different earphones and different ear simulators have different Zero Levels. Supra-aural earphones 4 Pure-tone Audiometer Calibration Different earphones and different ear simulators have different Zero Levels. Supra-aural earphones 4 Pure-tone Audiometer Calibration Different earphones and different ear simulators have different Zero Levels. High Frequency earphones 4 Pure-tone Audiometer Calibration Different earphones and different ear simulators have different Zero Levels. Insert earphones 4 Pure-tone Audiometer Calibration Different earphones and different ear simulators have different Zero Levels. Sound Field Contents 1 Significance of Calibration 2 International Standards 3 Traceability System 4 Pure-tone Audiometer Calibration 5 Impedance Audiometer Calibration 6 Hearing Screening Equipment Calibration 32 5 Impedance Audiometer Calibration manometer Sound Analyzer Audiometer Earphone and Ear Simulator Cavities 5 Impedance Audiometer Calibration JJG 991 Verification Regulation of Impedance Audiometer Frequency Probe Sound Pressure Level Admittance Pressure Frequency Ipsi earphone Sound Pressure Level Contra earphone Distortion Masking Sound 5 Impedance Audiometer Calibration Admittance Calibration: (put probe into different cavities in order) Cavities including: 0.1cc、0.2cc、0.5cc、1.0cc、2.0cc、3.0cc、4.0cc、5.0cc 5 Impedance Audiometer Calibration Pressure Calibration: (put probe into manometer) Measure Range: (-8 kPa ~ +8 kPa) Accuracy: ±50 Pa Contents 1 Significance of Calibration 2 International Standards 3 Traceability System 4 Pure-tone Audiometer Calibration 5 Impedance Audiometer Calibration 6 Hearing Screening Equipment Calibration 37 6 Hearing Screening Equipment Calibration Calibration method of OAE (Oto-Acoustic Emission) measurement system widely used in infants’ hearing screening IEC 60645-6, 2009 Instruments for the measurement of otoacoustic emissions Stimulus Low response signal Sound Signal OAE Infant Response Sound Signal Spontaneously Problems Stimulus and response should be calibrated at the same time 6 Hearing Screening Equipment Calibration Calibration method of AEP (Auditory Evoked Response) measurement system widely used in Objective Hearing Evaluation IEC 60645-7, 2009 Instruments for the measurement of auditory brainstem responses Stimulus Low response signal Sound Signal AEP Object Response Electrical Signal Spontaneously Problems Stimulus and response should be calibrated at the same time 6 Hearing Screening Equipment Calibration Different manufacturer have different calibration systems. These systems have a lot of Problems. NIM is developing a calibration system for OAE and ABR equipment. Prototype system has been finished, measurement experiments is doing now. 6 Hearing Screening Equipment Calibration Stimulus Unit Calibration Module According to ISO 389-6 6 Hearing Screening Equipment Calibration Response Measurement Unit Calibration Module Generate signal simulating the human ear response (OAE or ABR) 6 Hearing Screening Equipment Calibration Primary Calibration System for LS Microphone Primary Calibration System for Accelerometer Zero Level Standards of Air Conduction (Ear Simulator) Zero Level Standards of Bone Conduction (Artificial Mastoid) Calibration System for Audiometer Pure-tone Audiometer Imdedance Audiometer Speech Audiometer OAE Audiometer ABR Audiometer Thank You for Your Attention 44