Discover Kowa`s mobile retinal cameras!
Transcription
Discover Kowa`s mobile retinal cameras!
Handheld Retinal Camera Kowa Series Discover Kowa’s mobile retinal cameras! FA mode available now! NEW (for color retinal photography) (for color and FA retinal photography) Series Handheld Retinal Camera Kowa A series of handheld retinal cameras made of Kowa’s technology. ID input The best choice to start fundus photography! Integrated with a 2 megapixel digital camera ● ● ● One-handed ● Power GENESIS-D For color retinal photography One-handed easy shooting focusing and shooting operations supply unit which is used also as a camera holder NEW GENESIS-Df For color and FA retinal photography Timer display when saving FA images ●Focusing knob (on both sides) ●Shutter button (on both sides) ●Color / FA mode switching button ●Barrier filter knob Power supply unit's control panel Power supply unit's control panel Options for a more extended use Digital Imaging System Indirect lens holder "Kowa VK-2" Digital imaging system can be connected with "GENESIS-D" series and capturing images! Trunk Case Indirect lens holder Indirect lens holder (for +28D aspherical lens) (for +60D, +90D aspherical lenses) Foot Switch USB *Aspherical lenses are not included. Specifications Photographic modes GENESIS-D : COLOR GENESIS-Df: COLOR / FA Angle of field Horizontal 30° / Vertical 25° Working distance 5mm (between the top of cornea of examined eye and prism) Effective dioptic range of focusing -15D ∼ +35D Range of eyepiece correction -8D ∼ +5D Illumination for observation GENESIS-D: white LED GENESIS-Df: white LED / blue LED Illumination for shooting Xenon flash lamp / LED Filter (GENESIS-Df only) Exciter filter, barrier filter (manual insertion) Data recording (GENESIS-Df only) Timer Image sensor Monitor 2.5 inch TFT LCD monitor Record media CompactFlash (TYPE ) Image format 3 types of image recording formats are selectable FINE/NORMAL(compressed JPEG format) RAW DATA (uncompressed BMP format) Output terminal USB (1.1) terminal (B connector) Foot Switch connector cable terminal Power supply Input:AC100V- AC240V 50/60Hz Power consumption: 60VA(GENESIS-D), 150VA(GENESIS-Df) Dimensions / weight of the camera unit 74.5 (W) × 197 (D) × 278.5 (H) mm/1070g (2.36lbs.) Dimensions / weight of the power supply unit 180 (W) × 300 (D) × 230 (H) mm/1930g (4.25lbs.) 2 megapixel CCD ※Images of the monitor are compositions ※GENESIS is a registered trademark of Kowa Company, Ltd. in the United States, Germany, Japan and other countries. ※All other companies and product names stated here are trademark or registered trademark of each company. ※Specifications and appearances are subject to change without notice. Distribution name: KOWA GENESIS-D Distribution name: KOWA GENESIS-Df World Sales Headquarters 4-14, Nihonbashi-honcho 3-chome, Chuo-ku, Tokyo 103-8433 Japan Phone: 81(3)5623-8059 Facsimile: 81(3)5623-8060 URL: http://www.kowa.co.jp/e-life/ Hamamatsu Factory 3-1, Shinmiyakoda 1-chome, Kita-ku, Hamamatsu City, Shizuoka Pref., 431-2103 Japan Immermannstrasse 43B 40210 Duesseldorf, F.R. Germany Phone: 49(211)1793540 Facsimile: 49(211)161952 URL: http://kowa-europe.com/ 20001 S. Vermont Ave. Torrance, CA 90502, U.S.A. Phone: 1(310)327-1913 Facsimile: 1(310)327-4177 URL: http://kowa-usa.com/ This catalog was made with recycled paper. Printed in Japan K9L51/51B_0999200K Non-mydriatic Fundus Camera Kowa Non-mydriatic Fundus Camera Internal 8 megapixel Digital Camera Kowa The nonmydα-D Ⅲ is a compact digital camera that continues Kowa's tradition to fit the new age of electronic imaging technology. Kowa offers speed, reliability and high resolution photographs in a striking design. ERGONOMIC DESIGN HIGH RESOLUTION The all-in-one compact, lightweight digital fundus camera incorporates advanced technology in an efficient design. The nonmydα-DⅢ utilizes an internal 8 megapixel digital camera. This cost effective design uses intuitive ergonomic operations that makes The high resolution digital camera photographic results easy to capture. provides detailed, diagnostic quality images with Kowa's exclusive "Aspherical" optical system. EASY-TO-USE PLUG-AND-PLAY Easy to use controls are located at your fingertips. The conveniently located controls makes The nonmydα-DⅢ connects to the computer through a USB interface that makes set-up and operations plug and play. rapid screening easy; all operations can be carried out with the simple touch of a button. 9 POINTS INTERNAL FIXATION The nonmydα-DⅢ has two fixation modes that provide up to 9 fixation positions, "Normal" and "Mosaic". The "Mosaic mode" provides 9 fixation points for a panorama image covering a retinal area of approximately 85 degrees when using the "montage" application integrated in the digital imaging system. When using the "Normal mode" three positions are selectable Central, Disc and Macula. The camera can be used with either a desktop or notebook computer with the Kowa Portable VK-2 digital imaging system. Regardless of the volume of photographs taken, the nonmydα -DⅢ & Kowa Portable VK-2 lets you store, restore and compare data with ease. Shoot and forget allows easy image storage and automatic image saving. ■ Specifications Picture angle Shooting mode Effective pupil diameter Working distance Compensation range of examined eye Focusing Working distance adjustment Camera Monitor 45 °/30 ° two angles (optical) Normal / Mosaic (electrically switched) φ 4mm (small pupil mode: φ 3.5mm) 30mm (distance of examined eye to front end of objective lens) -1 Without compensation:-15m -1 (D)∼ +13m (D) Compensation -: -12m -1 (D)∼-32m -1 (D) -1 Compensation + :+10m -1 (D)∼ +40m (D) Split luminous bars coincidence 2 luminous dots indication type (anterior segment / fundus electrically switched) 8.3 megapixel CCD camera 5.7 inch LCD monitor Interface Internal fixation target External fixation target Optical head base moving distance Chin rest moving distance Power Supply Dimensions Weight Images of the monitor are compositions. nonmyd is a registered trademark of Kowa Company, Ltd. in the United States, Germany, Japan and other countries. Specifications and appearances are subject to change without notice. USB2.0 Normal: 3 positions (Central, Disc, Macula) Mosaic: 9 positions Red light (option) Movable 40mm forward / backward Movable 100mm leftward / rightward Movable 30mm vertically (electric) Movable 60mm (electric) Input: AC100V − AC240V 50 / 60Hz automatic voltage selection Power consumption: 150VA (normal) / 250VA (maximum) 310(W)× 505(D)× 462(H)mm 22kg / 48lbs. 2D/3D Non-mydriatic Retinal Camera / Analysis System Kowa 2D/3D Non-mydriatic Retinal Camera / Analysis System Specifications Camera Specific Nikon digital SLR camera Monitor 5.7 inch LCD monitor Internal fixation target Central, Disc, Macula, mosaic 8 positions 7.4° (at the 0 diopter eye) External fixation target Red light (option) Normal :45° SP:45° * Stereo:34° (20° ×27° ) Optical head base adjustment range Movable 40mm forward/backward Movable 98mm leftward/rightward Movable 27mm vertically (electric) Chin rest adjustment range Movable 55mm (electric) Interface USB Photograhy modes Normal / SP / Stereo (electrically switched) Stereoscopic photography method Simultaneous stereo photography Stereo photography parallax Field angle *Some eyes may cause a flare around their circumference. Working distance Minimum pupil size 30mm Normal mode:φ4.0mm SP mode:φ3.5mm Stereo mode:φ4.0mm Compensation range of examined eye Without compensation:−12D∼+13D Compensation −:−32D∼−10D Compensation + :+10D∼+35D Power supply Input:AC100−240V 50 / 60Hz Power consumption:150VA Focusing Split luminous bars coincidence Dimensions 310(W)×504(D)×548(H)mm Working distance adjustment 2 luminous dots indication type Weight 21kg / 46lbs (excluding the attached digital SLR camera) 3D ANALYSIS SYSTEM REQUIREMENTS CPU Celeron® 2.0 GHz or higher Memory 1 GB or higher Monitor resolution SXGA or higher OS Windows® XP, Windows Vista® Images of the monitor are compositions. nonmyd is a registered trademark of Kowa Company, Ltd. in the United States, Germany, Japan and other countries. Nikon is a trademark of Nikon Corporation. Celeron is a trademark of Intel Corporation in the United States and other countries. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Windows Vista is either a registered trademark or trademark of Microsoft Corporation in the United States and/or other countries. Specifications and appearances are subject to change without notice. Distribution name : KOWA nonmyd WX World Sales Headquarters 4-14, Nihonbashi-honcho 3-chome, Chuo-ku, Tokyo 103-8433 Japan Phone: 81(3)3279-7639 Facsimile: 81(3)3279-7541 URL: http://www.kowa.co.jp/e-life/ Hamamatsu Factory 3-1, Shinmiyakoda 1-chome, Kita-ku, Hamamatsu City, Shizuoka Pref., 431-2103 Japan Immermannstrasse 43B 40210 Duesseldorf, F.R. Germany Phone: 49(211)1793540 Facsimile: 49(211)161952 URL: http://kowa-europe.com/ 20001 S. Vermont Ave. Torrance, CA 90502, U.S.A. Phone: 1(310)327-1913 Facsimile: 1(310)327-4177 URL: http://kowa-usa.com/ REF K9L57/AP57B_1095MX Kowa 3D Analysis System 3D image analysis of optic disc nonmyd WX 3D Analysis System Contour line determination Photography Coming Soon. A new concept retinal camera with "SSP", Simultaneous Stereoscopic Photography. (manual/auto) Start up the analysis system at the display of stereo image. Cup and disc are plotted manually or automatically to support contour line determination. Three photography modes to choose from: Normal, SP(Small Pupil), and Stereo. Report output 3D analysis (PDF/JPEG) The analysis result is shown by the various parameters in the specified area. The analysis result can be output in PDF and / or JPEG format. Determination of cup Determination of disc 2D − Normal & SP − Normal Field angle:45° Kowa's exclusive optical design in combination with the 12 megapixel digital SLR camera delivers extremely detailed retinal images. The integrated 9-points internal fixation system allows for mosaic photography covering a large retinal area. SP(Small Pupil) Field angle:45° Retinal images can be taken even with smaller pupils. On screen guides indicate if the pupil size is within the sufficient range (above 3.5mm) for photography. ① Depth distribution ② ① Color-coded display of the depth distribution in the analysis area, or graphical display of the cross section of an arbitrary position. Automatic mosaic merge function Mosaic images are created easily with automatic image rotation & alignment. Normal ③ ④ Glaucoma ※ Some eyes may cause a flare around their circumference. ⑥ ⑤ Analysis results 3D 3D display −Stereo− Numerical data of analysis results ③ Display of optic disc parameters. Stereo Field angle:34°(20°×27°) Polar coordinates display ④ Photography Instant and simultaneous 3D photography is possible in 1-shot. Stereoscopic images are captured without image/parallax shifts. The polar coordinates display of the depth distribution permits visual display of the thin part of the rim. (marginal region of optic disc) Retinal observation on 3D images Contour line depth distribution graph ⑤ Graphical display of the depth distribution of cup and disc profiles. The shape of the optic cup and disc can be viewed in a 3D image. Switch between the parallel and cross viewing methods with 1-click when viewed on a 2D monitor. Follow-up ⑥ Parallel/Cross view icon (Icon may be hidden.) Image capturing Graphical display of cup/disc ratio, rim/disc ratio, cup area, and many other parameters. ② Display of 3D image based on stereographic data. DDLS ( disc damage likelihood scale ) Stage Indexical values defined by the disc size and the rim/disc ratio; which was suggested by Dr. George L. Spaeth as a method to diagnose the optic disc. Bayer A, Harasymowycz P, Henderer JD, et al.: Validity of a new diskgrading scale for estimating glaucomatous damage: correlation with visual field damage. American Journal of Ophthalmology, vol. 133 (6),pp.758-763, 2002. Mydriatic/ Non-Mydriatic Integrated Retinal Camera KOWA Mydriatic/ Non-Mydriatic Integrated Retinal Camera KOWA Specifications Photography modes Non-mydriatic color Mydriatic color Fluorescein fundus angiography (FA) Red-free (RF) Fundus autofluorescence (FAF) Field of view Non-mydriatic mode : 45°/27° Mydriatic mode : 50°/30° (SP:45°/27°) Working distance 39mm (between the examined eye and the object lens) Minimum pupil diameter Non-mydriatic mode : φ4.0mm (SP φ3.5mm) Mydriatic mode : φ5.5mm (SP1 φ4.0mm/SP2 φ3.5mm) Focusing Internal fixation light Central/disc/macula/peripheral External fixation light Red/green LED Exposure Appropriate exposure is automatically set based on the 37-steps (0.6WS to 300WS) of field angle, filter, and photography mode Camera Higher than 12 megapixel CMOS sensor Monitor 7 inch wide-screen touch LCD Adjustment range Forward/backward:(gross)90mm,(micromotion)approx. 17.5mm Leftward/rightward:(gross)140mm,(micromotion)approx. 17.5mm Upward/downward: 30mm Tilting:(elevation)11°, (depression)15° Panning:(left/right)30° horizontally Recording medium CF memory card Interface USB : VK-2 connection Printer connection Card reader connection LAN : Image output Power saving function Yes Power supply Input : AC 120/230V 50/60Hz Power consumption : 250 VA 1500 VA (Max.) Dimensions 390(W)×540(D)×720(H)mm Weight 39kg/86lbs Split luminous bars coincidence Range of focus adjustment for compensation of patient's refractive error Without compensation : -12D to + 13D Compensation : -32D to - 10D Compensation + : +10D to + 35D Range of diopter adjustment of the optical finder -8D to +5D Working distance adjustment Luminous dot indication (ON/OFF switchable) Light source For observation : Halogen lamp For photography : Xenon flash lamp Flash compensation ±5 steps Options Internal fixation target Grip Auxiliary forehead rest Images in the LCD monitor are compositions. All other companies and product names stated here are trademaek or registered trademark of each company. Specifications and appearances are subject to change without notice. World Sales Headquarters 4-14, Nihonbashi-honcho 3-chome, Chuo-ku, Tokyo 103-8433 Japan Phone: +81(3)3279-7639 Facsimile: +81(3)3279-7541 URL: http://www.kowa.co.jp/e-life/ Kowa Company, Ltd. Hamamatsu Factory 3-1, Shinmiyakoda 1-chome, Kita-ku, Hamamatsu City, Shizuoka Pref., 431-2103 Japan FAF filter set Distribution name : KOWA VX-20 20001 S. Vermont Ave., Torrance, CA 90502, U.S.A. Phone: +1(310)327-1913 Facsimile: +1(310)327-4177 URL: http://kowa-usa.com/ Sandhurst House, 297 Yorktown Road, Sandhurst, Berkshire GU47 0QA, U.K. Phone: +44(127)693-7021 Facsimile: +44(127)693-7023 E-mail: [email protected] URL: http://www.kowa.eu Immermannstrasse 43B, 40210 Duesseldorf, F.R. Germany Phone: +49(211)1793540 Facsimile: +49(211)161952 E-mail: [email protected] URL: http://www.kowa.eu REF K9L56_1188500MK/K Printed in Japan. New Innovative design in full pursuit of retinal camera, both patient-friendly and easy-to-use for operator Enhanced photography features 5 photography modes including FAF* In addition to the non-mydriatic color, mydriatic color, fluorescein fundus angiography (FA), Red-free (RF) modes, fundus autofluorescence (FAF*) mode is added to allow 5-modes photography. Also, the SP mode that allows photography of φ3.5 mm of small pupils is equipped. Fluorescein fundus angiography (FA) Non-mydriatic color Mydriatic color Red-free (RF) Fundus autofluorescence (FAF*) Photo : Showa University Option * Updated design providing stress-free diagnosis Down 75mm reduced height of examined eye from our previous model ("VX-10" series), allowing photography in a relaxed posture. 75mm VX-20 VX-10α (Previous model) Instant image filing software is equipped. The instant image filing feature allows ID management of images, browsing, and direct output to the external printer. In addition, images can be output to every electric medical records of any manufacturers through the network, not to mention by connecting to the image filing system Kowa VK-2. Optical variable 2 angles Field of view can be switched between 45°/27° in non-mydriatic mode or between 50°/30° in mydriatic mode by a simple pressing of a button. 2 Fundus can be observed through the optical viewfinder. In mydriatic mode, the fundus can be observed through the optical viewfinder, allowing photography of images exactly as viewed. This feature is particularly helpful for photographing peripheral part of the retina. 3 VX-20, simple operation with various useful features, supporting smooth daily medical practices! Focusing on design for operability Design:Chin rest Eye level indication can be easily seen even in the darkroom. Stable chassis that makes it easy to assist in eyelid opening. Only usable switch buttons are illuminated according to each photography mode, enabling smooth and quick photography even in the darkroom. Moving chin rest up/down and switching field of view are electrically performed, that can be operated at hand. SP (Small Pupil) photography mode In mydriatic mode, either φ3.5mm or φ4.0mm can be selected. In non-mydriatic mode, φ3.5mm is available. * The SP mode is not supported in RF mode. * With φ3.5mm photography, some eyes may cause a flare around their circumference. Photography with φ4.0mm Design:Tilt angle The downward tilt angle has been expansion to 11 degrees. Thus, facilitating upward-angle shoots, which have been difficult with the conventional models. * As with compared to our previous models. Photo: Showa University External fixation light switching Central/disc/macula/peripheral, and external fixation light can be switched with a single touch of a button. High resolution photography The special digital camera built-in. The easy image storage. Wide-screen touch LCD monitor Wide-screen touch LCD monitor is employed, on which the image is displayed in the center with touch panel icons effectively placed along both sides of the screen. It also provides easier operation with the easy-to-see touch LCD monitor. 4 Custom buttons Photographic sensitivity, diaphragm, and photographic intensity can be set by the user. Depending on the patient, photographic settings can be easily adjusted with simple operations, for example, by increasing the sensitivity to allow patient-friendly photography or to compensate the insufficient light intensity for the FA later phase. Photography with monitor observation In mydriatic color, FA, RF, and FAF modes, photography under the monitor observation that can reduce the photophobia of the patient is also possible, in addition to the normal viewfinder observation. 5 Instant image filing function Example of System Configuration Capture mode Stand-alone The capture mode allows the user to input IDs and display the alignment images or images just captured. 1 Viewer button 1 Used to switch from the capture mode to the viewer mode. 2 3 2 ID input button Equipped with the instant image filing function using a touch panel. ID input from the card reader is possible. Multiple-image display (4 images). Photography data is saved in the CF memory card. Allows direct printing to the printer. Used to input the ID. Pressing this button to display the ID input screen. 4 USB 3 Fixation light selection button Used to select the fixation light. Pressing this button displays fixation light buttons to allow selection. Printer 4 Custom buttons Used to select user-set photographic conditions. Network * When connecting to the image filing system Kowa VK-2, the image just captured is displayed on the monitor of the image filing system. Direct connection with the intranet via LAN. Inspecting room Consultation room ID input from the Kowa VX-20 is possible. Photographic data can be saved in the network terminal. l. Viewer mode LAN Allows direct printing using the preview display. The viewer mode allows the user to browse the images saved in the selected ID, and print or delete the displayed image. 1 Capture button 1 2 Used to input the ID. Pressing this button to display the ID input screen. 3 Review button The previously captured image will be displayed. 5 6 Third-party image filing system/ electric medical record 2 ID input button 3 4 Kowa VK-2 Used to switch to the capture mode. 4 View button The next captured image will be displayed. 7 5 Multi-button 4 images in the same ID will be displayed. Connecting to the image filing system Kowa VK-2 All the captured images can be freely saved and managed. Data sharing on the intranet is possible. Equipped with the multi-timer function for FA photography. hy. Options 6 Print button Print out the displayed image. 7 Trash button USB Delete the displayed image from the CF memory card. Automatic mosaic merge function *When connecting to the image filing system Kowa VK-2, the viewer mode is not available. 6 Photo: Showa University PDT irradiation area calculationsupport software 7