www.casals.tv GENERAL PRICE LIST 2011
Transcription
www.casals.tv GENERAL PRICE LIST 2011
GENERAL PRICE LIST 2011 www.casals.tv SELECTION SOFTWARE Free download: Download the new version of the Casals Ventilación calculation and fans selection software. Visit the DOWNLOADS section at www.casals.tv, where you can download the setup file for free and always up-to-date. Software online: Now you can also use the software online, with no need to download or install it on your computer. Visit the PRODUCT section in our website. Main uses: -Search of the suitable fan according to a specific flow and pressure. -Calculation of ventilation needs in different types of installations. -Fan reports (general and technical characteristics, dimensions and performance curves). -Calculation of pressure drop in ventilation systems through a practical graphic application. New features: -Search optimization, faster and more accurate. -Acoustic data, SWL and SPL spectrums for the working point. -Multiple selection which allows searching for 5, 10 or 500 fans at the same time. It is possible to import and export data from spreadsheets, ideal for projects. -Comparison of different fans in one graph. -Datasheets for fans and accessories in PDF. -Dynamic graphs, with zoom and pan tools. -Updates alert. -Search engine to find fans and accessories. -Advanced Filter tools for a better definition in searches. 2 THE COMPANY AND ITS EVOLUTION The history of Casals goes back to the end of the XIX century (1881) when the founder Francesc Casals Fransoy opened a small workshop in the centre of Ripoll (Girona). From the mechanizing of the cast iron pieces and the making of machinery for factories and workshops, this small business developed through the years and became a business dedicated to the manufacturing of spare parts for tools and afterwards to the tooling manufacturing. At this point Talleres Casals was founded, located in a new industrial area also in Ripoll. In 1924 Casals started manufacturing the first models of industrial fans. At first the series production systems were applied but they developed into the current and modern lines of production. In this way Casals became the leader of the industry. With time, Talleres Casals diversified the production and nowadays Casals Ventilation, one of its divisions, has its own entity and is independent from the rest. Located in Sant Joan de les Abadesses, in a 12.000m2 factory, it manufactures over 100 different types and models of fans, supplying the national and international market. In the last few years the evolution has been very satisfactory and nowadays the export percentage exceeds 36% of the benefits. This growth has driven Casals Ventilation to expand the physical space and the personnel, and open a new factory in Ripoll where the low pressure fan series are produced. Currently, as a fan manufacturer of fans with over 125 years of experience, Casals Ventilation has a wide catalogue available in the market of technical ventilation for building constructions and industrial fans. In this catalogue the wide range of certified fans of 400ºC/2h is amongst the most important and noticeable items found. In addition to the professional technical team prepared to resolve the doubts, Casals supplies the most appropriate product to satisfy the needs and projects of the clients. 3 BRANCH OFFICES IN SPAIN Andalucía Huelva - Sevilla - Cádiz - Málaga - Córdoba - Jaén - Granada. CENTRAL Tel.: 972720150 Fax: 972721053 E-mail: [email protected] Andorra Sr. Toni Soler Tel.: 00 376 364 661 E-mail: [email protected] Aragón Zaragoza - Huesca - Teruel - Soria. CENTRAL Tel.: 972720150 Fax: 972721053 E-mail: [email protected] Asturias Sr. Alfredo Fernández Tel.: 649 863 890 E-mail: [email protected] Castilla y León Salamanca - Valladolid - Yamora - León Palencia. Sr. Rafael Villagrá Tel.: 667 502 310 E-mail: [email protected] Extremadura Sr. Mario Rodríguez Tel.: 618.744.444 E-mail: [email protected] Balears Sr. Diego Friggeri Tel.: 636 714 770 E-mail: [email protected] Catalunya Sr. José A. Borrallo Aguilera Tel.: 676061377 E-mail: [email protected] Sr. Samuel Batlle Tel.: 619605058 E-mail: [email protected] Sr. Francesc Bellot Tel.: 609672597 E-mail: [email protected] Levante Sur Alicante - Murcia - Almería - Albacete. Galicia Sra. Marta Vega (edificación) Tel.: 687 775 631 E-mail: [email protected] Sr. Antonio Suárez (industrial) Tel.: 678 675 342 E-mail: [email protected] 4 Sr. Diego Friggeri Tel.: 636 714 770 E-mail: [email protected] Canarias CENTRAL Tel.: 972720150 E-mail: [email protected] Centro Madrid - Segovia - Ávila - Toledo - Guadalajara - Cuenca - Ciudad Real. Sr. Luis Miguel Vázquez Tel.: 659 951 624 E-mail: [email protected] Sr. Miguel Ángel Casillas 629 100 944 E-mail: [email protected] Norte Cantabria - La Rioja - Navarra - Álava Vizcaya - Guipúzcoa - Burgos. Sr. Aitor Irusta Tel.: 627 525 001 E-mail: [email protected] Castellón - Valencia. Sr. Aitor Lezama Tel.: 672 001 835 E-mail: [email protected] Sr. Juanjo Martínez Tel.: 629 686 781 E-mail: [email protected] Sr. Mikel Garagorri Tel.: 629 604 310 E-mail: [email protected] Levante Norte EXPORT BRANCH OFFICES Export Contact CASALS VENTILACIÓN Ctra. Camprodon s/n 17860 Sant Joan de les Abadesses (Girona) SPAIN Tel.: +34 972720150 Fax: +34 972721053 E-mail: [email protected] 5 TO TAKE INTO ACCOUNT MODELS DESCRIPTION GENERIC DESCRIPTION OF THE MODELS The description of the fans models in this price list generally follow the same structure. The description is composed by the series name, followed by the size of the impeller, the type of motor (single phase or three phase), the number of motor poles and its power. In the case of free shaft fans the motor information will not be shown. SERIES SIZE EXAMPLE WITH MOTOR: HBF 125 EXAMPLE WITH FREE SHAFT BST 9/4 1ph / 3ph POLES POWER T 4 22kW POWER UNITS The power of the fan motor is described in kW. For the equivalence in HP, please use the following table: Power (CV) = 1,36 x Power (kw) Power (CV) = 0,00136 x Power (w) DIMENSIONS UNITS Axial fans impellers are described in cm. EXAMPLE: HMX 80 For centrifugal fans we find the following cases: LOW PRESSURE “impeller diameter/impeller width” in inches: BV25/20 INDUSTRIAL TYPE 1 “impeller diameter/impeller width” in cm: BV25/10 INDUSTRIAL TYPE 1 “impeller diameter” in mm: MZRL 400 TABLE OF MOST FREQUENT EQUIVALENCES HP 1/4 1/3 1/2 3/4 1 1,5 2 3 4 5,5 7,5 10 15 20 25 30 KW 0,18 0,25 0,37 0,55 0,75 1,1 1,5 2,2 3 4 5,5 7,5 11 15 18,5 22 INCHES 5 7 9 10 12 15 18 20 22 24 26 CM 13 19 25 28 33 39 47 51 56 63 68 ACOUSTIC VALUES About the acoustic values shown in the fans tables: 6 Centrifugal roof fans Average sound pressure level (SPL) in dB(A), outlet side, measured on a horizontal plane from 5m. Cabinet and inline fans, except for BOX HB and its variants Average sound pressure level (SPL) in dB(A), with both inlet and outlet ducted, measured in open field from 1,5m. Axial fans, including axial roof fans, BOX HB and its variants Average sound pressure level (SPL) in dB(A), inlet side, measured in open field from a distance of 3 times the impeller diameter with a minimum of 1,5m. Centrifugal fans without cabinet Average sound pressure level (SPL) in dB(A), measured in open field from 1,5m with ducted outlet. Jet fans Average sound pressure level (SPL) in dB(A) in open field from a distance of 5m. ALPHANUMERIC INDEX AA 45/5-60/7 AA 47-70 AA P/R AAVA AAVC AAVG/N AAVM AAVP AAZA P/R AAZVA AAZVC AAZVG/N AAZVG/P AAZVM AAZVP AAZZA AC BA-400 BC BCI BD BD 3V BD CUBIC BDE BE BEA S/C BEH BEIRM BERM BIRM BOX ANTARES BOX BD BOX BD CA BOX BST BOX BSTB BOX BSTBF BOX BV BOX BV CA BOX HB BOX HBF BOX HBFX BOX HBX BOX RL BOX RLF BOX RLFX BOX SIRIUS BOX VEGA BP BS BST BT BT ILF 100 BT ILF 4-8 BT ROOF BTI BV BVC BVCR BVFC 103 103 109 104 105 107 108 106 110 111 111 111 111 111 111 111 132 134 77 79 72 74 72 75 34 34 34 34 34 34 35 26 26 29 31 55 27 27 23 40 40 114 25 45 45 35 35 131 78 32 33 33 20 131 76 76 76 52 CFR CI CP CTH CTH 400º CTH+KITV CTH+KITV 400º DAL DB DCB DG DHS DPS EAA EAA S EAA SH EI FILTERS HA HB HBA HBF HBFX HBX HH HHP HI HJB HJBPA HJEPA HJRE HM HMA HMF HMFX HMTE HMX HTE HTR HTRE INT INT 3V JE-45 JF KBD-KHB-KTE MA 18-25 MA 26-31 MA P/R MAX MB MB P/R MBC/FA MBC/FA 400º MBCA MBGR MBI MBP MBPC 35 136 135 18 49 18 49 58 58 57 58 57 123 34 34 34 132 135 64 65 65 38 38 113 70 71 69 63 61 60 62 67 67 42 42 15 116 14 17 17 123 123 134 44 33 80 81 87 117 83 88 86 50 85 97 133 100 101 MBPCX MBPX MBR MBRC F/A MBRC/FA 400º MBRF MBRH MBRL MBRLP MBRM MBRU MBX MBZM P/R MC HB MDE MDI MOTORS MZ MZCA MZGR MZRL MZRM MZRU MZZM P/R OKTOPUS OM PC PCP PE PI PO PS RA RAI RCIB REG REGD-1 RFS RI RM RP RP0 RP1 S SB SBE SF SIL-C SIL-R SUST TCA TIAC TM TRANSMISSION SETS VIS VMC VULCAN 120 119 90 91 51 46 98 92 94 95 96 118 89 133 82 99 124 84 102 102 102 102 102 102 35 129 128 128 123 128 130 130 127 127 36 122 122 122 126 126 125 125 126 130 22 21 47 136 136 54 134 135 131 124 129 34 20 7 INDEX BUILDING TECHNICAL VENTILATION ROOF FANS HTE p.14 HMTE p.15 HTR p.17 HTRE p.17 CTH p.18 CTH+KITV p.18 BOX RL p.25 BOX BD p.26 BOX BD CA p.26 BT ILF 100 p.33 KBD-KHB-KTE p.33 VULCAN p.20 BT ROOF p.20 INLINE FANS SBE p.21 SB p.22 BOX HB p.23 BOX BST p.29 BOX BSTB p.31 BT p.32 BT ILF 4-8 p.33 BOX BV p.27 BOX BV CA p.27 ENERGY SAVING EAA p.34 BERM p.34 EAA S p.34 CFR p.35 EAA SH p.34 OKTOPUS p.35 BE p.34 BOX SIRIUS p.35 BEA S/C p.34 BEH p.34 BOX ANTARES p.35 BEIRM p.34 BOX VEGA BP p.35 BIRM p.34 RCIB p.36 SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA 8 HBF p.38 HBFX p.38 BOX RLFX p.45 MBRF p.46 BOX HBF p.40 SF p.47 BOX HBFX p.40 HMF p.42 HMFX p.42 JF p.44 BOX RLF p.45 INDEX CTH p.49 CTH+KITV p.49 MBC/FA p.50 MBRC/FA p.51 BVFC p.52 SUST p.54 BOX BSTBF p.55 BUILDING VENTILATION SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA DHS p.57 DCB p.57 DB p.58 DAL p.58 INDUSTRIAL VENTILATION DOMESTIC RANGE DG p.58 INDUSTRIAL VENTILATION ATEX FANS AXIAL FANS HJEPA p.60 HJBPA p.61 HJRE p.62 HJB p.63 HA p.64 HB p.65 HBA p.65 BVC p.76 BVCR p.76 HM p.67 HMA p.67 HI p.69 HH p.70 ACCESSORIES LONG CASED AXIAL FANS HHP p.71 BD p.72 BD CUBIC p.72 BC p.77 BST p.78 BD 3V p.74 BDE p.75 BV p.76 TECHNICAL CONCEPTS CENTRIFUGAL LOW PRESSURE FANS 9 INDEX CENTRIFUGAL MEDIUM PRESSURE FANS BCI p.79 MA 18-25 p.80 MA 26-31 p.81 MDE p.82 MA P/R p.87 MB P/R p.88 MBZM P/R p.89 MBR p.90 MBRU p.96 MBGR p.97 MBRH p.98 MDI p.99 MB p.83 MZ p.84 MBCA p.85 MBC/FA p.86 MBRC FA p.91 MBRL p.92 MBRLP p.94 MBRM p.95 MBP p.100 MBPC p.101 BELT DRIVEN p.102 AAVP p.106 AAVG/N p.107 AAVM p.108 MBX p.118 MBPX p.119 CENTRIFUGAL HIGH PRESSURE FANS AA 47-70 p.103 AAZA P/R p.110 AA 45/5-60/7 p.103 AAVA p.104 AAVC p.105 BELT DRIVEN p.111 ATEX FANS HBX p.113 10 BOX HBX p.114 HMX p.116 MAX p.117 MBPCX p.120 AA P/R p.109 INDEX BUILDING VENTILATION ELECTRICAL ACCESSORIES REG p.122 REGD-1 p.122 RFS p.122 INT p.123 INT 3V p.123 DPS p.123 PE p.123 MOTORS AND TRANSMISSSION SETS p.124 MECHANICAL ACCESSORIES INDUSTRIAL VENTILATION GUARDS, SHUTTERS AND DAMPERS PCP p.128 RP0 p.125 PI p.128 RP1 p.126 OM p.129 RI p.126 RM p.126 RA p.127 RAI p.127 PC p.128 VIS p.129 ATEX FANS RP p.125 SUPPORTS, FEET AND BASES S p.130 PO p.130 PSp.130 BTI p.131 BS p.131 TM p.131 TIAC p.135 AC p.132 CP p.135 MBI p.133 MC HB p.133 BA-400 p.134 JE-45 p.134 TCA p.134 FILTERS p.135 TECHNICAL CONCEPTS EI p.132 ACCESSORIES COUPLING FLANGES, DAMPER COVERS AND FILTERS SILENCERS AND SOUNDPROOF CABINETS SIL-C p.136 SIL-R p.136 CI p.136 11 12 BUILDING TECHNICAL VENTILATION ROOF FANS INLINE FANS ENERGY SAVING SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA DOMESTIC RANGE 13 ROOF FANS HTE Axial with fiberglass cowl MANUFACTURING FEATURES •Roof cowl made of reinforced plastic. •Roof base support and bird protection guard with epoxy powder finishing coat. •Variable pitch angle polyamide impeller reinforced with fiberglass. •Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors, 230/400V 50Hz and for three phase motors. UNDER REQUEST • B Form impeller (air flow from impeller to motor) • 60Hz fans. APPLICATIONS Specially designed for roof installation, they are suitable for: •Air renewal in buildings and industries. •Smoke extraction. • Maximum working temperature: single phase 50ºC, three phase 60ºC. ACCESSORIES REG RFS INT PE BTI OM SINGLE PHASE RANGE Code Model R.P.M. max. 267300103 267310103 267350103 267410103 267440103 267460103 HTE 35 M4 0,08kW HTE 40 M4 0,25kW HTE 45 M4 0,37kW HTE 50 M4 0,55kW HTE 56 M4 0,75kW HTE 56 M6 0,25kW 1370 1400 1400 1400 1400 900 Max. Curr. (A) 230 400 0,9 2,02 2,77 4,25 5,45 2,07 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,08 0,25 0,37 0,55 0,75 0,25 2610 4230 6750 7650 10120 6940 60 65 66 70 71 68 15 21 28 35 42 41 R.R.P. € 697,40 740,40 911,70 1.083,80 1.179,60 1.192,60 THREE PHASE RANGE Code 267300106 267310106 267350106 267410106 267440106 267450106 267460106 14 Model HTE 35 T4 0,08kW HTE 40 T4 0,25kW HTE 45 T4 0,37kW HTE 50 T4 0,55kW HTE 56 T4 0,75kW HTE 56 T4 1,1kW HTE 56 T6 0,25kW R.P.M. max. 1400 1400 1400 1400 1400 1400 900 Max. Curr. (A) 230 400 0,04 1,44 1,94 2,69 3,48 4,74 1,51 0,2 0,83 1,12 1,56 2,01 2,75 0,87 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,08 0,25 0,37 0,55 0,75 1,1 0,25 2610 4230 6750 7650 10120 11180 6940 60 65 66 70 71 72 68 15 21 28 35 42 43 41 R.R.P. € 682,60 736,00 877,00 1.068,10 1.154,00 1.160,60 1.176,90 ROOF FANS HMTE Axial with fiberglass cowl MANUFACTURING FEATURES • Roof cowl made of reinforced plastic. • Roof base support and bird protection guard with epoxy powder finishing coat. • Polyamide impeller with variable pitch angle reinforced with fiberglass. • Assembled with fans from HM (long cased) ranges. • Protection guard in compliance with the ROHS 2002/95 Directive. • Standard asynchronous squirrel-cage motor, IP55 protection and rated class F insulation. Manufactured with standard voltages 230V 50Hz in single phase motors and 230/400V 50Hz for three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Smoke extraction. • Maximum working temperature: single phase 50ºC, three phase 60ºC. UNDER REQUEST • B form impeller (air flow from impeller to motor), 100% reversible impeller and cast aluminium impellers. • 60Hz fans and special voltages. • 2 speed motors. • Assembled with flameproof and explosionproof HM ATEX fans. • Hot-dipped galvanised and stainless steel housing. APPLICATIONS Specially designed for roof installation, they are suitable for: • Air renewal in buildings and industries. ACCESSORIES REG RFS INT PE BTI 15 ROOF FANS SINGLE PHASE RANGE Code 269070103 269270103 269100103 269290103 269310103 269330103 269560103 269680103 269760103 Model HMTE 25 M2 0,12kW HMTE 25 M4 0,08kW HMTE 30 M2 0,37kW HMTE 30 M4 0,12kW HMTE 35 M4 0,12kW HMTE 40 M4 0,25kW HMTE 56 M4 0,55kW HMTE 63 M6 0,37kW HMTE 71 M6 0,55kW R.P.M. max. 2770 1370 2800 1400 1400 1400 1400 900 900 Max. Curr. (A) 230 400 0,98 0,9 2,73 1,1 1,1 2,02 4,25 2,69 3,84 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,12 0,08 0,37 0,12 0,12 0,25 0,55 0,37 0,55 2660 990 2790 1400 2610 4230 9060 9150 12320 70 55 71 56 60 64 73 63 68 12 12 16 14 17 20 36 45 61 - R.R.P. € 665,60 666,30 684,40 676,00 749,60 899,00 1.150,40 1.480,90 1.565,70 THREE PHASE RANGE Code 269070106 269270106 269100106 269290106 269140106 269310106 269150106 269330106 269160106 269350106 269380106 269320106 269620106 269400106 269660106 269680106 269690106 269430106 269740106 269760106 269780106 269420106 269820106 269840106 269860106 269440106 269910106 269450106 269930106 269460106 269960106 16 Model HMTE 25 T2 0,12kW HMTE 25 T4 0,08kW HMTE 30 T2 0,37kW HMTE 30 T4 0,12kW HMTE 35 T2 0,37kW HMTE 35 T4 0,12kW HMTE 40 T2 1,1kW HMTE 40 T4 0,25kW HMTE 45 T2 1,5kW HMTE 45 T4 0,37kW HMTE 56 T4 0,55kW HMTE 56 T6 0,25kW HMTE 56 T6 0,55kW HMTE 63 T4 1,1kW HMTE 63 T4 2,2kW HMTE 63 T6 0,37kW HMTE 63 T6 0,55kW HMTE 71 T4 1,5kW HMTE 71 T4 3kW HMTE 71 T6 0,55kW HMTE 71 T6 1,1kW HMTE 80 T4 3kW HMTE 80 T4 4kW HMTE 80 T6 1,1kW HMTE 80 T6 2,2kW HMTE 90 T4 3kW HMTE 90 T4 4kW HMTE 90 T4 5,5kW HMTE 90 T4 7,5kW HMTE 90 T6 1,5kW HMTE 90 T6 3kW R.P.M. max. 2800 1400 2800 1400 2800 1400 2800 1400 2800 1400 1400 900 900 1400 1430 900 900 1400 1430 900 910 1430 1440 910 940 1430 1440 1440 1440 940 960 Max. Curr. (A) 230 400 690 0,67 0,035 1,65 0,84 1,65 0,84 4,42 1,44 6,01 1,94 2,69 1,51 2,85 4,74 8,06 2,13 2,85 4,74 11,7 2,85 5,5 11,7 15,2 5,5 9,7 11,7 15,2 6,9 12,4 0,38 0,2 0,95 0,48 0,95 0,48 2,55 0,83 3,48 1,12 1,56 0,87 1,65 2,75 5 1,23 1,65 2,75 6,8 1,65 3,2 6,8 8,8 3,2 5,6 6,8 8,8 12 15 4 7,2 6,9 8,6 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,12 0,08 0,37 0,12 0,37 0,12 1,1 0,25 1,5 0,37 0,55 0,25 0,55 1,1 2,2 0,37 0,55 1,5 3 0,55 1,1 3 4 1,1 2,2 3 4 5,5 7,5 1,5 3 2660 990 2790 1400 4680 2610 7650 4230 10890 6750 9060 6940 8140 13200 16810 9150 9940 17600 21650 12320 15710 27980 30960 20670 24500 30030 35460 39500 44030 24460 31930 70 55 71 56 77 60 80 64 84 69 72 62 63 74 75 63 64 80 81 66 68 83 84 73 74 87 88 89 91 77 80 12 12 16 14 17 16 23 20 30 28 36 36 37 53 66 45 47 61 78 61 70 101 106 92 103 115 120 135 146 113 141 R.R.P. € 655,60 659,40 658,90 668,10 744,30 740,00 975,20 886,10 1.066,10 971,00 1.123,60 1.089,70 1.205,20 1.376,30 1.589,00 1.400,30 1.406,20 1.523,90 1.665,90 1.558,90 1.717,10 2.129,10 2.249,50 2.080,40 2.180,90 2.154,90 2.231,60 2.337,20 2.457,70 2.755,40 2.930,20 ROOF FANS HTR/HTRE Axial, galvanized steel, adjustable inclination base MANUFACTURING FEATURES • Completely manufactured in galvanised steel sheet. • Polyamide impeller with variable pitch angle reinforced with fiberglass. • Bird protection guard included. • 0% standard inclination. HTR RANGE: • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors. HTR HTRE RANGE: • Static fans, i.e. with no electrical motor (minimum air speed requested to start the fan: 2,5 m/sec). APPLICATIONS Specially designed for roof installation, they are suitable for: • Air renewal in buildings and industries. • Smoke extraction. • Maximum working temperature: 60ºC. • 2 speed motors. • Single phase motors. • Flameproof and explosionproof fans with ATEX certified motors and 3-meter RVFV 4x2, 5mm core cable. • Custom pitch according to roof slope: Type A Model 570: 0% - 18% Model 740: 0% - 15% Type B Model 570: 19% - 38% Model 740: de 15% a 30% • Fan inclination under customer’s request. Standard fan inclination: 0%. • Fans with self-adjustable base support, up to a 38% maximum slope. • Motorised damper with registered motor in IP-65 box to avoid heat loss in winter. • ‘Double channel’ function to exhaust air in dropped ceilings and closed environments at the same time and save energy and investment. • Lacquered or stainless steel finishing coat. UNDER REQUEST • B form impeller (air flow from impeller to motor), 100% reversible impeller. • Aluminium impeller. • 60Hz fans and special voltages. HTRE ACCESSORIES RFS INT PE HTR Code 300287400 300287500 300287600 300287700 300287800 300287900 300345400 300359800 300349400 300360100 300346100 300433800 Model HTR 570 T4 HTR 570 T6 HTR 570 T8 HTR 740 T6 HTR 740 T8 HTR 920 T6 HTR-A 570 T4 HTR-A 570 T6 HTR-A 570 T8 HTR-A 740 T6 HTR-A 740 T8 HTR-B 570 T4 HTR-B 570 T6 HTR-B 570 T8 HTR-B 740 T6 HTR-B 740 T8 R.P.M. max. Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1400 900 680 910 680 940 1400 900 680 910 680 1400 900 680 910 680 0,55 0,25 0,09 1,1 0,55 2,2 0,55 0,25 0,09 1,1 0,55 0,55 0,25 0,09 1,1 0,55 9060 6940 5665 15710 11780 28310 9060 6940 5665 15710 11780 9060 6940 5665 15710 11780 72 60 55 70 63 81 72 60 55 70 63 72 60 55 70 63 52 52 52 67 67 89 52 52 52 67 67 52 52 52 67 67 Air flow m3/h Weight Kg 1912 3225 4987 52 67 89 R.R.P. € 1.442,10 1.457,60 1.457,60 2.389,70 2.389,70 3.543,90 1.545,50 1.545,50 1.611,80 2.437,70 2.437,70 1.545,50 1.545,50 1.611,80 2.437,70 2.437,70 HTRE Code 300288000 300288100 300288200 Model HTRE 570 HTRE 740 HTRE 920 R.R.P. € 954,50 1.045,80 1.470,60 17 ROOF FANS CTH Centrifugal, PE cowl MANUFACTURING FEATURES • Roof cowl made of polyethylene UV resistant. • Structure, roof base support and bird protection guard made of galvanised steel. • High Efficiency backward curved impellers of galvanised steel. • Vertical discharge when adding the accessory KITV. • Standard asynchronous motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors, 230/400V 50Hz in three phase motors and 400V 50Hz in 2 speed motors. CTH (horizontal) • Air renewal in buildings and industries. • Industrial and professional kitchen hoods. • Maximum continuous operation temperature: 80ºC. UNDER REQUEST • Security switch mounted and wired. • 60Hz and special voltages. • Sparkproof fans with ATEX certified motors. APPLICATIONS Specially designed for roof installation, they are suitable for: • Smoke extraction. • Smoke emergency exhaust with motor outside the hazardous area (400ºC/2h certificate). CTH + KITV (vertical) ACCESSORIES REG RFS INT PE SINGLE PHASE RANGE Code Model R.P.M. max. Max. Curr. (A) 230 Rated Power kW Air flow m3/h Weight Kg CTH Weight Kg CTH+KITV 300815900 300816000 300816100 300816200 300816300 300816400 300816500 300816600 300816700 CTH 28 M4 0,22kW CTH 32 M4 0,22kW CTH 36 M4 0,22kW CTH 40 M4 0,37kW CTH 45 M4 0,75kW CTH 45 M6 0,25kW CTH 50 M4 1,1kW CTH 50 M6 0,37kW CTH 56 M6 0,75kW 1450 1450 1450 1450 1450 950 1450 950 950 2,2 2,2 2,2 3,1 5,4 2,3 7 3 6,5 0,22 0,22 0,22 0,37 0,75 0,25 1,1 0,37 0,75 1300 1850 2700 3750 5500 3670 7500 5000 6940 22 22 24 32 38 33 43 37 62 26 26 28 40 46 41 51 45 75 Air flow m3/h Weight Kg CTH Weight Kg CTH+KITV 1300 1850 1240 2700 1800 3750 2500 5500 3670 7500 5000 10400 6940 5200 9900 7430 15000 11250 20000 15000 22 22 20 23 21 31 29 35 34 41 37 67 60 60 74 73 111 105 136 131 26 26 24 27 25 39 37 43 42 49 45 80 73 73 87 86 132 126 157 152 R.R.P. € CTH 645,50 653,10 717,70 903,70 1.013,90 1.040,40 1.222,70 1.211,30 1.587,20 R.R.P. € CTH+KITV 706,10 714,70 780,30 1.012,70 1.123,90 1.151,40 1.334,70 1.324,30 1.756,80 THREE PHASE RANGE Code 300816800 300816900 300817000 300817100 300817200 300817300 300817400 300817500 300817600 300817700 300817800 300817900 300818000 300818100 300818200 300818300 300818400 300818500 300818600 300818700 18 Model CTH 28 T4 0,25kW CTH 32 T4 0,25kW CTH 32 T6 0,25kW CTH 36 T4 0,25kW CTH 36 T6 0,25kW CTH 40 T4 0,37kW CTH 40 T6 0,25kW CTH 45 T4 0,75kW CTH 45 T6 0,37kW CTH 50 T4 1,1kW CTH 50 T6 0,37kW CTH 56 T4 2,2kW CTH 56 T6 0,75kW CTH 56 T8 0,37kW CTH 63 T6 1,5kW CTH 63 T8 0,75kW CTH 71 T6 2,2kW CTH 71 T8 1,1kW CTH 80 T6 4kW CTH 80 T8 2,2kW R.P.M. max. 1450 1450 950 1450 950 1450 950 1450 950 1450 950 1450 950 725 950 725 950 725 950 725 Max. Curr. (A) Rated Power kW 230 400 0,48 0,48 0,5 0,48 0,5 0,64 0,71 1,13 0,71 1,52 0,71 2,77 1,27 0,78 2,19 1,39 3,12 1,85 5,31 3,44 0,84 0,84 0,87 0,84 0,84 1,1 1,23 1,95 1,23 2,6 1,23 4,8 2,2 1,35 3,8 2,4 5,4 3,2 9,2 5,96 0,25 0,25 0,25 0,25 0,25 0,37 0,25 0,75 0,37 1,1 0,37 2,2 0,75 0,37 1,5 0,75 2,2 1,1 4 2,2 R.R.P. CTH 609,90 630,10 630,10 630,10 630,10 775,50 775,50 872,40 832,00 1.046,10 981,40 1.397,40 1.268,20 1.336,90 1.619,60 1.462,10 1.898,30 1.861,90 2.152,70 2.306,20 R.R.P. CTH+KITV 670,50 690,70 690,70 690,70 690,70 884,50 884,50 981,40 941,00 1.155,10 1.090,40 1.567,00 1.437,80 1.506,50 1.789,20 1.631,70 2.177,00 2.140,60 2.431,40 2.584,90 ROOF FANS THREE PHASE RANGE 2 SPEEDS Code Model R.P.M. max. Max. Curr. (A) 400V Rated Power kW Air flow m3/h Weight Kg CTH Weight Kg CTH+KITV 300818800 300818900 300819000 300819100 300819200 300819400 300819300 300819500 300819600 300819800 300819700 300819900 300820000 300820100 300820200 300820300 300820400 300820500 300820600 CTH 32 T4/T8 0,37-0,08kW CTH 36 T4/T8 0,37-0,08kW CTH 40 T4/T8 0,37-0,08kW CTH 45 T4/T8 0,8-0,2kW CTH 45 T6/T8 0,25-0,12kW CTH 50 T4/T6 1,1-0,3kW CTH 50 T4/T8 1,2-0,3kW CTH 50 T6/T8 0,37-0,2kW CTH 50 T6/T12 0,37-0,07kW CTH 56 T4/T6 2,2-0,7kW CTH 56 T4/T8 2,2-0,55kW CTH 56 T6/T8 0,75-0,37kW CTH 56 T6/T12 0,75-0,2kW CTH 63 T6/T8 1,5-0,75kW CTH 63 T6/T12 1,5-0,75kW CTH 71 T6/T8 2,2-1,3kW CTH 71 T6/T12 2,2-0,55kW CTH 80 T6/T8 4- 1,1kW CTH 80 T6/T12 4-1,0kW 1450/725 1450/725 1450/725 1450/725 950/725 1450/950 1450/725 950/725 950/450 1450/950 1450/725 950/725 950/450 950/725 950/450 950/725 950/450 950/725 950/450 1,8/0,5 1,8/0,5 1,8/0,5 2/0,9 1/0,94 3/1,5 2,9/1,3 1,5/1,1 1,59/0,7 5,2/2,5 5/2 2,7/1,7 2,4/1 4/3 4,3/1,7 6,5/5 6,4/2,6 11,3/4,9 12,6/5,2 0,37/0,08 0,37/0,08 0,37/0,08 0,8/0,2 0,25/0,12 1,1/0,3 1,2/0,3 0,37/0,2 0,37/0,07 2,2/0,7 2,2/0,55 0,75/0,37 0,75/0,15 1,5/0,75 1,5/0,75 2,2/1,3 2,2/0,55 4/1,1 4/1,0 1850/930 2700/1350 3750/1880 5500/2750 3670/2750 10400/6940 7500/3750 5000/3750 5000/2500 10400/6940 10400/5200 6940/5200 6940/3470 9900/7430 9900/4950 15000/11250 15000/7500 20000/15000 20000/10000 22 23 31 36 33 44 44 37 41 71 80 62 63 93 75 127 116 145 131 26 27 39 44 41 52 52 45 49 84 93 75 73 106 88 148 137 166 152 R.R.P. CTH 735,10 735,10 880,50 997,60 1.074,30 1.288,40 1.171,30 1.252,00 1.134,90 1.676,10 1.510,50 1.619,60 1.579,20 1.813,40 2.092,10 2.209,20 2.512,20 2.770,60 2.867,60 R.R.P. CTH+KITV 709,6 709,6 880,3 985,6 1.054,50 1.246,90 1.141,70 1.109,00 1.214,30 1.644,40 1.495,60 1.557,30 1.593,60 1.318,30 1.767,80 2.484,80 2.212,60 2.804,30 2.490,80 19 ROOF FANS VULCAN Centrifugal, special for fireplaces and barbecues, 200ºC continuous MANUFACTURING FEATURES • Bird protection guard included. • Manufactured with standard voltages: 230V/50Hz. • Structure in galvanised steel, external parts in three options: VULCAN ST: galvanised steel VULCAN AL: anodized aluminium VULCAN CO: copper APPLICATIONS Specially designed for smoke extraction up to 200ºC in fireplaces and barbecues. VULCAN-ST ACCESSORIES Model INT PE R.P.M. max. I (A) 230V Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1400 0,42 0,09 1000 52 18 VULCAN-ST BT ROOF 578,40 Centrifugal, small applications MANUFACTURING FEATURES • Steel sheet set with epoxy powder finishing coat. • Roof base support and bird protection guard. • Assembled with fans from BT range. • Asynchronous external rotor with thermal protector and greased for life ball bearings. • IP-44 protection and rated class B insulation according to DIN 40.050 h1. Standard voltages 230V 50Hz. ACCESSORIES R.R.P. € REG INT APPLICATIONS Specially designed for roof installation, they are suitable for: • Air renewal in bathrooms and small closed environments. • Maximum working temperature: 50ºC. PE SINGLE PHASE RANGE Code 300740800 300740900 20 Model BT ROOF 150 BT ROOF 250 R.P.M. max. Max. Curr. (A) 230 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 2450 2600 0,43 0,85 0,07 0,18 450 1180 38 46 5,6 8,8 R.R.P. € 214,10 267,60 INLINE FANS AND ENERGY SAVING SBE Centrifugal in low profile cabinet, external rotor motor MANUFACTURING FEATURES • Completely manufactured in galvanised steel sheet including the impeller. • Inlet and outlet circular flanges to help the duct fans assembly. • External wiring box. • Open-up design of the motor to make cleaning and maintenance easier. • Asynchronous external rotor, IP-44 protection and rated class B insulation according to DIN 40.050 h1 and greased for life ball bearings. Standard voltages 230V 50Hz. ACCESSORIES REG INT APPLICATIONS Designed for inline installation, they are suitable for: • Air renewal in bathrooms and small closed environments. • Perfect for installation in dropped ceilings or outdoors. • Maximum working temperature: 50ºC. PE SINGLE PHASE RANGE Model SBE 10-24 SBE 12-34 SBE 15-44 SBE 16-44 SBE 20-54 SBE 25-64 SBE 31-64 R.P.M. max. 2730 2640 2530 2540 1380 1380 1350 Max. Curr. (A) 230 400 0,58 0,59 0,82 0,82 0,90 0,86 0,93 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,11 0,11 0,17 0,17 0,17 0,17 0,20 280 390 565 599 840 980 1210 58 62 64 66 59 60 62 4,4 4,6 4,9 5 9,7 10,2 11 R.R.P. € 150,40 155,00 159,50 161,60 232,00 265,80 308,90 21 INLINE FANS AND ENERGY SAVING SB Centrifugal in low profile soundproof cabinet, external rotor motor MANUFACTURING FEATURES • Completely manufactured in galvanised steel sheet including the impeller. • Soundproof box with Flexiroll Pol Na 30 Anthracite grey, M1 fire resistance insulated panels. • Inlet and outlet circular flanges to make the duct fan assembly easier. • Asynchronous external rotor, IP-44 protection and rated class B insulation according to DIN 40.050 h1 and greased for life ball bearings. Standard voltages 230V 50Hz. ACCESSORIES REG INT APPLICATIONS Designed for inline installation, they are suitable for: • Air renewal in bathrooms and small closed environments. • Perfect for installation in dropped ceilings and outdoors. • Maximum working temperature: 50ºC. PE SINGLE PHASE RANGE Code 240120143 240150143 240200143 240210143 240250143 240260143 240350143 240360143 22 Model SB 125/H SB 150/H SB 200/H SB 200/L SB 250/H SB 250/L SB 355/H SB 355/L R.P.M. max. Max. Curr. (A) 230 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 2700 2600 2600 2450 2660 2600 1400 1350 0,48 0,96 0,67 0,42 0,92 0,67 0,76 0,55 0,11 0,21 0,14 0,1 0,2 0,14 0,18 0,12 400 550 875 700 1300 1100 2500 2100 30 40 45 44 49 47 52 51 4,5 6,2 7,5 7,5 9,75 9,75 26 26 R.R.P. € 193,30 222,40 264,00 258,00 275,50 276,90 525,20 519,70 INLINE FANS AND ENERGY SAVING BOX HB Axial in soundproof cabinet MANUFACTURING FEATURES • BOX: soundproof galvanised steel box with Flexiroll Pol Na 30 anthracite grey M1 fire resistance insulated panels. Easy motor access and fan maintenance through removable panels. Internal fan: • HB: axial fan, circular reinforced frame. Motorimpeller assembly through a modular system. Variable pitch angle polyamide impeller reinforced with fiberglass. Epoxy powder finishing coat. • HBA: axial fan, circular reinforced frame. Motorimpeller assembly through a modular system. Cast aluminium impeller with variable pitch angle. Epoxy powder finishing coat. APPLICATIONS Designed for wall or duct installation, they are suitable for: • Air renewal in buildings and industries. • Smoke extraction. • Maximum working temperature: single phase 50ºC, three phase 60ºC. UNDER REQUEST • B form, 100% reversible impeller. • 60Hz fans and special voltages. • ATEX models BOX HBX: general ventilation in closed environments classified as ATEX zone 1 or 2. • Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors, 230/400V 50Hz for three phase motors up to 4kW, and 400/690V 50Hz for higher powers. ACCESSORIES REG INT PE RFS RP0 RP1 JE 45 SINGLE PHASE RANGE Code Model R.P.M. max. 260410x43 260470x43 260480x43 270450x43 260500x43 260510x43 260560x43 260600x43 260680x43 260760x43 BOX HB 40 M4 0,25kW BOX HB 45 M4 0,37kW BOX HB 45 M6 0,12kW BOX HB 45 M6 0,25kW BOX HB 50 M4 0,55kW BOX HB 50 M6 0,25kW BOX HB 56 M4 0,55kW BOX HB 56 M6 0,25kW BOX HB 63 M6 0,37kW BOX HB 71 M6 0,55kW 1400 1400 900 900 1400 900 1400 900 900 900 Max. Curr. (A) 230 400 2,02 2,77 1,05 2,07 4,25 2,07 4,25 2,07 2,69 3,84 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,25 0,37 0,12 0,25 0,55 0,25 0,55 0,25 0,37 0,55 4700 7500 5200 5500 10065 6000 11330 8680 11440 15400 61 68 51 52 67 55 70 58 63 68 49 45 44 45 49 50 52 49 52 59 - R.R.P. € R.R.P. € Polyamide Aluminium 758,3 778,4 926,8 937,3 817 936,3 909,9 1.011,70 983,7 1.166,90 856,8 879,6 1.047,30 1.059,20 923,2 1.058,00 1.028,10 1.143,20 1.111,50 1.318,60 THREE PHASE RANGE Code 260400x46 260410x46 260450x46 260460x46 260470x46 260480x46 260480x46 260500x46 260510x46 260560x46 260570x46 260580x46 260590x46 260600x46 260610x46 Model BOX HB 40 T2 1,1kW BOX HB 40 T4 0,25kW BOX HB 45 T2 1,5kW BOX HB 45 T2 2,2kW BOX HB 45 T4 0,37kW BOX HB 45 T6 0,12kW BOX HB 45 T6 0,25kW BOX HB 50 T4 0,55kW BOX HB 50 T6 0,25kW BOX HB 56 T4 0,55kW BOX HB 56 T4 0,75kW BOX HB 56 T4 1,1kW BOX HB 56 T4 1,5kW BOX HB 56 T6 0,25kW BOX HB 56 T6 0,37kW R.P.M. max. 2800 1400 2800 2800 1400 900 850 1400 900 1400 1400 1400 1400 900 900 Max. Curr. (A) 230 400 690 4,42 1,44 6,01 8,61 1,94 0,52 1,08 2,69 1,51 2,69 3,48 4,74 6,31 1,51 2,13 2,55 0,83 3,48 4,98 1,12 0,3 0,62 1,56 0,87 1,56 2,01 2,75 3,65 0,87 1,23 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,1 0,25 1,5 2,2 0,37 0,12 0,25 0,55 0,25 0,55 0,75 1,1 1,5 0,25 0,37 8500 4700 12100 13500 7500 5200 5500 10065 6000 11330 12650 13970 15600 8680 9500 85 61 85 87 67 53 54 67 55 70 71 72 73 59 59 67 59 67 68 44 49 50 49 50 52 53 57 59 49 52 R.R.P. € R.R.P. € Polyamide Aluminium 746,6 701,4 854,3 888 774,2 765,1 777,3 807,5 787,7 883,4 903,9 1.026,20 1.057,70 862,5 969,6 843,6 792,6 965,3 1.003,50 874,8 864,6 878,4 912,5 890,1 998,3 1.021,40 1.159,60 1.195,20 974,6 1.095,70 23 INLINE FANS AND ENERGY SAVING Code R.P.M. max. Model 260620x46 260630x46 260640x46 260650x46 260660x46 260670x46 260680x46 260690x46 260700x46 260710x46 260720x46 260730x46 260740x46 260760x46 260770x46 260780x46 260800x46 260810x46 260820x46 260830x46 260840x46 260850x46 260860x46 260900x46 260910x46 260920x46 260930x46 260940x46 260950x46 260960x46 260100x46 260110x46 260120x46 260130x46 260140x46 260150x46 260160x46 260220x46 260230x46 260240x46 260250x46 260260x46 260270x46 260280x46 260290x46 BOX HB 56 T6 0,55kW BOX HB 63 T4 0,75kW BOX HB 63 T4 1,1kW BOX HB 63 T4 1,5kW BOX HB 63 T4 2,2kW BOX HB 63 T4 3kW BOX HB 63 T6 0,37kW BOX HB 63 T6 0,55kW BOX HB 63 T6 0,75kW BOX HB 71 T4 1,1kW BOX HB 71 T4 1,5kW BOX HB 71 T4 2,2kW BOX HB 71 T4 3kW BOX HB 71 T6 0,55kW BOX HB 71 T6 0,75kW BOX HB 71 T6 1,1kW BOX HB 80 T4 2,2kW BOX HB 80 T4 3kW BOX HB 80 T4 4kW BOX HB 80 T6 0,75kW BOX HB 80 T6 1,1kW BOX HB 80 T6 1,5kW BOX HB 80 T6 2,2kW BOX HB 90 T4 3kW BOX HB 90 T4 4kW BOX HB 90 T4 5,5kW BOX HB 90 T4 7,5kW BOX HB 90 T6 1,5kW BOX HB 90 T6 2,2kW BOX HB 90 T6 3kW BOX HB 100 T4 5,5kW BOX HB 100 T4 7,5kW BOX HB 100 T4 11kW BOX HB 100 T4 15kW BOX HB 100 T6 2,2kW BOX HB 100 T6 3kW BOX HB 100 T6 4kW BOX HB 125 T4 11kW BOX HB 125 T4 15kW BOX HB 125 T4 18,5kW BOX HB 125 T4 22kW BOX HB 125 T6 3kW BOX HB 125 T6 4kW BOX HB 125 T6 7,5kW BOX HB 125 T6 11kW 900 1400 1400 1400 1430 1430 900 900 910 1400 1400 1430 1430 900 910 910 1430 1430 1440 910 910 940 940 1430 1440 1440 1440 940 940 960 1440 1440 1460 1460 940 960 960 1460 1460 1465 1470 960 960 965 970 Max. Curr. (A) 230 400 690 2,85 3,48 4,74 6,31 8,06 11,7 2,13 2,85 4 4,74 6,31 8,06 11,7 2,85 4 5,5 8,06 11,7 15,2 4 5,5 6,9 9,7 11,7 15,2 6,9 9,7 12,4 9,7 12,4 16,3 12,4 16,3 - 1,65 2,01 2,75 3,65 5 6,8 1,23 1,65 2,3 2,75 3,65 5 6,8 1,65 2,3 3,2 5 6,8 8,8 2,3 3,2 4 5,6 6,8 8,8 12 15 4 5,6 7,2 12 15 20,9 27,9 5,6 7,2 9,4 20,9 27,9 33 38,5 7,2 9,4 16,1 22,4 6,9 8,6 6,9 8,6 12,02 16,04 12,02 16,04 18,98 22,14 9,26 12,88 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,55 0,75 1,1 1,5 2,2 3 0,37 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 2,2 3 4 0,75 1,1 1,5 2,2 3 4 5,5 7,5 1,5 2,2 3 5,5 7,5 11 15 2,2 3 4 11 15 18,2 22 3 4 7,5 11 10170 14080 16500 18620 21010 23430 11440 12430 13860 20570 22000 23870 27060 15400 17480 19640 29700 34980 38700 23100 25840 28600 30620 37540 44320 49370 55040 30580 35390 39910 53080 61590 66450 71510 37740 45690 51450 82600 89000 97300 103700 50000 55800 73600 88600 60 60 70 71 72 73 60 61 62 75 76 77 78 63 64 65 80 81 82 67 70 71 72 84 85 87 88 75 76 77 89 89 90 91 79 80 81 91 91 92 92 77 78 80 82 53 57 61 63 72 74 56 57 61 77 79 89 91 73 77 79 97 99 104 85 87 97 100 122 127 143 154 120 123 139 151 162 186 203 131 147 152 302 312 340 352 245 259 253 259 R.R.P. € R.R.P. € Polyamide Aluminium 1.006,70 938,9 975,8 994,2 1.118,60 1.174,20 919,6 1.014,30 1.089,80 1.143,50 1.241,50 1.287,40 1.313,30 1.098,40 1.229,40 1.302,90 1.377,60 1.404,60 1.509,80 1.277,50 1.329,60 1.358,40 1.464,40 1.760,00 1.809,70 2.140,30 2.240,10 1.805,40 1.856,70 1.918,40 2.339,20 2.429,20 2.811,90 2.911,80 2.072,70 2.217,70 2.426,30 5.003,70 5.123,20 5.428,60 5.605,50 4.454,80 4.654,00 5.003,70 5.140,90 1.137,50 1.061,00 1.102,60 1.123,40 1.264,00 1.326,80 1.039,20 1.146,20 1.231,40 1.292,10 1.402,80 1.454,70 1.484,00 1.241,20 1.389,30 1.472,20 1.556,70 1.587,20 1.706,10 1.443,60 1.502,40 1.535,00 1.654,80 1.988,80 2.045,00 2.418,50 2.531,30 2.040,10 2.098,10 2.167,80 2.643,30 2.745,00 3.177,40 3.290,30 2.342,20 2.506,00 2.741,70 5.654,10 5.789,20 6.134,30 6.334,20 5.034,00 5.259,00 5.654,10 5.809,20 x=1 Polyamide (BOX HB) x=2 Aluminium (BOX HBA) THREE PHASE RANGE 2 SPEEDS Model R.P.M. max. Max. Curr. (A) 400V Rated Power kW Air flow m3/h Sound dB (A) Weight Kg BOX HB 56 T4/T8 0,85-0,20kW BOX HB 56 T4/T8 1,40-0,30kW BOX HB 56 T4/T8 1,80-0,40kW BOX HB 63 T4/T8 0,85-0,20kW BOX HB 63 T4/T8 1,40-0,30kW BOX HB 63 T4/T8 1,80-0,40kW BOX HB 63 T4/T8 2,20-0,60kW BOX HB 63 T4/T8 2,80-0,70kW BOX HB 71 T4/T8 1,40-0,30kW BOX HB 71 T4/T8 1,80-0,40kW BOX HB 71 T4/T8 2,20-0,60kW BOX HB 71 T4/T8 2,80-0,70kW BOX HB 80 T4/T8 2,20-0,60kW BOX HB 80 T4/T8 2,80-0,70kW BOX HB 80 T4/T8 4,00-1,00kW BOX HB 90 T4/T8 2,80-0,70kW BOX HB 90 T4/T8 4,00-1,00kW BOX HB 90 T4/T8 6,50-1,80kW BOX HB 100 T4/T8 6,50-1,80kW BOX HB 100 T4/T8 10,0-2,50kW BOX HB 100 T4/T8 16,0-4,50kW 1380/685 1395/705 1375/695 1380/685 1395/705 1375/695 1420/690 1420/695 1395/705 1375/695 1420/690 1420/695 1420/690 1420/695 1435/695 1420/695 1435/695 1455/720 1460/725 1450/730 1470/730 1,76/0,77 3,63/1,21 4,44/1,43 1,76/0,77 3,63/1,21 4,44/1,43 5,34/2,18 6,3/2,42 3,63/1,21 4,44/1,43 5,34/2,18 6,3/2,42 5,34/2,18 6,3/2,42 9,2/3,7 6,3/2,42 9,2/3,7 13,3/4,4 13,9/5,62 20,2/6,6 28,6/9,3 0,85/0,20 1,40/0,30 1,80/0,40 0,85/0,20 1,40/0,30 1,80/0,40 2,20/0,60 2,80/0,70 1,40/0,30 1,80/0,40 2,20/0,60 2,80/0,70 2,20/0,60 2,80/0,70 4,00/1,00 2,80/0,70 4,00/1,00 6,50/1,80 6,50/1,80 10,0/2,50 16,0/4,50 12650/6325 13970/6985 15600/7800 14080/7040 16500/8250 18620/9310 21010/10505 23430/11715 20570/10285 22000/11000 23870/11935 27060/13530 29700/14850 34980/17490 38700/19350 37540/18770 44320/22160 49370/24685 53080/26540 66450/33225 71510/35755 70/46 71/47 72/48 72/48 74/49 75/50 76/51 77/52 76/50 77/51 78/52 79/53 80/54 81/55 82/56 83/57 84/58 85/59 86/59 87/60 89/62 49 56 59 57 60 63 71 72 75 79 88 90 96 97 102 120 125 150 159 184 200 24 R.R.P. € Polyamide 1.018,60 1.147,10 1.203,20 1.211,90 1.231,30 1.274,80 1.371,40 1.429,50 1.368,80 1.402,80 1.494,60 1.567,20 1.712,20 1.799,20 1.881,40 2.229,00 2.277,40 2.765,80 3.046,20 3.413,70 4.154,30 R.R.P. € Aluminium 1.151,00 1.296,20 1.359,60 1.369,50 1.391,30 1.440,60 1.549,70 1.615,30 1.546,80 1.585,10 1.688,90 1.770,90 1.934,70 2.033,10 2.125,90 2.518,80 2.573,50 3.125,30 3.442,20 3.857,50 4.694,30 INLINE FANS AND ENERGY SAVING BOX RL Backward centrifugal in soundproof cabinet MANUFACTURING FEATURES • Box manufactured in galvanised steel sheet. Soundproof cabinets with Flexiroll Pol Na 30 Anthracite grey M1 fire resistance insulated panels. • Circular inlet and outlet • Backward impeller, direct coupling motor. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. • Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Possible exchange of panels to change the air flow sideways. ACCESSORIES RFS INT PE BA-400 SIL-C APPLICATIONS Designed for inline installation, they are suitable for: • Air renewal in buildings and industries. • Maximum working temperature: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • ATEX motor fans. • Vertical discharge. SIL-R JE 45 THREE PHASE RANGE Model R.P.M. max. BOX RLF 400 T4/L 0,75kW BOX RLF 400 T4/H 0,75kW BOX RLF 450 T4 1,1kW BOX RLF 500 T4 1,5kW BOX RLF 500 T6 0,75kW BOX RLF 560 T4/L 3kW BOX RLF 560 T4/H 3kW BOX RLF 560 T6/L 1,5kW BOX RLF 560 T6/H 1,5kW BOX RLF 630 T4 5,5kW BOX RLF 630 T6 1,5kW BOX RLF 710 T4/L 7,5kW BOX RLF 710 T4/H 7,5kW BOX RLF 710 T6/L 3kW BOX RLF 710 T6/H 3kW BOX RLF 800 T4 15kW BOX RLF 800 T6 4kW 1400 1400 1400 1420 910 1410 1410 930 930 1450 930 1420 1420 955 955 1430 955 Max. Curr. (A) 230 400 690 3,48 4,74 6,31 4 11,7 11,7 6,9 6,9 6,9 5,54 12,4 12,4 7,45 - 2,01 2,75 3,65 2,3 6,8 6,8 4 4 12 6,9 4 3,2 15 8,6 7,2 7,2 4,3 30,59 17,68 9,35 5,37 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,75 0,75 1,1 1,5 0,75 3 3 1,5 1,5 5,5 1,5 7,5 7,5 3 3 15 4 4500 4500 5971 9000 6180 11600 12378 7750 8250 17000 11673 21500 23000 15050 16500 27900 19500 52 61 62 64 66 68 69 71 72 54 56 59 63 65 59 75 66 114 132 137 143 129 152 182 150 179 216 183 228 258 258 215 336 274 R.R.P. € 1.655,70 1.655,70 1.894,60 2.035,00 2.160,70 2.286,50 2.392,30 2.215,50 2.447,00 2.916,80 2.588,60 3.334,70 3.459,30 3.202,20 2.886,20 4.192,40 3.251,50 THREE PHASE RANGE 2 SPEEDS Model BOX RLF 400/H T4/T8 0,75-0,15kW BOX RLF 450 T4/T8 1,1-0,18kW BOX RLF 500 T4/T8 1,5-0,25kW BOX RLF 560/H T4/T8 3-0,55kW BOX RLF 630 T4/T8 5,5-1,1kW BOX RLF 710/H T4/T8 7,5-1,5kW R.P.M. max. Max. Curr. (A) 400V Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1380/685 1370/695 1375/700 1400/700 1455/720 1455/720 2,33/0,88 2,33/0,88 4,44/1,43 6,3/2,42 10,2/3,09 13,9/5,62 0,7-0,15 1-0,22 1,5-0,35 2,5-0,65 4,7-1,1 6,4-1,4 3950/2000 5971/2980 8250/4125 12275/6150 16300/8150 23623/11810 80/57 58/47 61/49 64/51 66/53 68/54 132 137 143 182 216 258 R.R.P. € 1.911,70 2.140,70 2.301,00 2.738,80 3.560,10 4.153,20 25 INLINE FANS AND ENERGY SAVING BOX BD BOX BD CLEAN AIR Centrifugal in soundproof cabinet, CA models with G4 filter MANUFACTURING FEATURES • Impellers made of polyamide reinforced with fiberglass up to size 12/12. Other models made of galvanised steel sheet. • BD range fans assembled in soundproof cabinets with Flexiroll Pol Na 30 anthracite grey M1 fire resistance insulated panels. • Fan assembled on antivibration mountings. • Connection gland included. • Equipped with inlet deflector wing, minimizing turbulence and optimizing efficiency. • Closed motors specially designed by Casals. Extruded aluminium motor housing. Totally enclosed wiring box IP-65. IP-54 motor protection and rated class F insulation. Standard voltages 230V 50 Hz for single phase and 230/400V 50Hz. • Clean air: BD fans with integrated G4 filter (particles 10μm performance 94%). Removable filter frame from both sides of the box for better maintenance. Replaceable and washable filtering foam. BOX BD Optimized suctioning air inlet to maximize the fan performance. APPLICATIONS Designed for inline installation, indoor or outdoor assembly, they are suitable for: • Air renewal in buildings and industries. • Industrial and professional kitchen hoods. • Maximum working temperature: 50ºC. UNDER REQUEST • 3 speed fans. • Vertical discharge, circular inlet and outlet, blind cover. • LG0 position. BOX BD CLEAN AIR ACCESSORIES REG RFS INT PE PI VIS TCA TIAC JE 45 SINGLE PHASE RANGE Model BOX BD / CLEAN AIR BOX BD 7/7 M4 0,15kW BOX BD 7/7 M6 0,08kW BOX BD 9/9 M4 0,37kW BOX BD 9/9 M4 0,55kW BOX BD 9/9 M6 0,15kW BOX BD 9/9 M6 0,25kW BOX BD 10/10 M4 0,55kW BOX BD 10/10 M6 0,25kW BOX BD 10/10 M6 0,37kW BOX BD 12/12 M6 0,55kW BOX BD 12/12 M6 0,75kW BOX BD 12/12 M6 1,1kW Equivalence (cm) R.P.M. max. 19/19 19/19 25/25 25/25 25/25 25/25 28/28 28/28 28/28 33/33 33/33 33/33 1300 860 1350 1350 850 900 1350 900 890 860 840 860 Max. Curr. (A) 230 400 1,85 1,03 2,83 4,86 1,69 2,33 4,86 2,33 3,33 4,93 6,86 9,26 - Rated Power kW Air flow m3/h Sound dB (A) 0,15 0,08 0,37 0,55 0,15 0,25 0,55 0,25 0,37 0,55 0,75 1,1 1400 1400 3200 3300 2530 2620 3690 3230 3710 5590 6250 7200 50 50 54 55 50 52 56 54 54 57 57 59 Rated Power kW Air flow m3/h Sound dB (A) 1,1 2,2 7200 10800 58 67 R.R.P. € BOX BD 343,50 343,50 416,10 420,70 406,30 414,80 452,80 440,40 444,60 590,60 603,10 659,40 R.R.P. € BOX BD CA 425,30 425,30 504,50 509,10 494,70 503,20 547,80 535,30 539,60 692,10 704,60 760,90 THREE PHASE RANGE Model BOX BD / CLEAN AIR BOX BD 12/12 T6 1,1kW BOX BD 15/15 T6 2,2kW 26 Equivalence (cm) R.P.M. max. 33/33 39/39 960 900 Max. Curr. (A) 230 400 6,54 10,92 3,78 6,31 R.R.P. € BOX BD 618,50 998,00 R.R.P. € BOX BD CA 720,00 1.156,40 INLINE FANS AND ENERGY SAVING BOX BV BOX BV CLEAN AIR Belt driven centrifugal in soundproof cabinet, CA models with G4 filter MANUFACTURING FEATURES • Impellers made of polyamide reinforced with fiberglass up to size 12/12. Other models are made of galvanised steel sheet. • BV, BVC, BVCR range fans assembled in soundproof cabinets with Flexiroll Pol Na 30 Anthracite grey or fiberglass (big sizes), M1 fire resistance insulated panels. • Fan assembled on antivibration mountings. • Supplied with motor, pulleys and belts. • Connection gland included. • Equipped with inlet deflector wing, minimizing the turbulence and optimizing the efficiency. • Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230/400V 50Hz for three phase, motors up to 4kW and 400/690V 50Hz for higher powers. BOX BV CLEAN AIR • BV fans with integrated G4 filter (particles 10μm performance 94%). Removable filter frame from both sides of the box for better maintenance. Replaceable and washable filtering foam. Optimized suctioning air inlet to maximize the fan performance. APPLICATIONS Designed for inline installation, indoor or outdoor assembly, they are suitable for: • Air renewal in buildings and industries. • Industrial and professional kitchen hoods. • Maximum working temperature: 60ºC. CLEAN AIR: • Contributes to a cleaner free of particles air. UNDER REQUEST • 60Hz fans and special voltages. • 2 SPEED MOTORS. • Vertical discharge, circular inlet and outlet, blind cover. • Transmission ratio variation. • LG0 position. BOX BV CLEAN AIR ACCESSORIES RFS INT PE PI VIS TCA TIAC JE 45 27 INLINE FANS AND ENERGY SAVING THREE PHASE RANGE Max. Curr. (A) Model BOX BV/ CLEAN AIR Equivalence (cm) R.P.M. max. 230 400 690 BOX BV 7/7 0,18kW BOX BV 7/7 0,25kW BOX BV 7/7 0,37kW BOX BV 7/7 0,55kW BOX BV 7/7 0,75kW BOX BV 9/9 0,37kW BOX BV 9/9 0,55kW BOX BV 9/9 0,75kW BOX BV 9/9 1,1kW BOX BV 10/10 0,37kW BOX BV 10/10 0,55kW BOX BV 10/10 0,75kW BOX BV 10/10 1,1kW BOX BV 10/10 1,5kW BOX BV 12/12 0,37kW BOX BV 12/12 0,55kW BOX BV 12/12 0,75kW BOX BV 12/12 1,1kW BOX BV 12/12 1,5kW BOX BV 12/12 2,2kW BOX BV 15/15 0,55kW BOX BV 15/15 0,75kW BOX BV 15/15 1,1kW BOX BV 15/15 1,5kW BOX BV 15/15 2,2kW BOX BV 15/15 3kW BOX BV 15/15 4kW BOX BV 18/18 1,1kW BOX BV 18/18 1,5kW BOX BV 18/18 2,2kW BOX BV 18/18 3kW BOX BV 18/18 4kW BOX BV 18/18 5,5kW BOX BV 20/20 1,5kW BOX BV 20/20 2,2kW BOX BV 20/20 3kW BOX BV 20/20 4kW BOX BV 20/20 5,5kW BOX BV 20/20 7,5kW BOX BV 22/22 1,5kW BOX BV 22/22 2,2kW BOX BV 22/22 3kW BOX BV 22/22 4kW BOX BV 22/22 5,5kW BOX BV 22/22 7,5kW BOX BV 22/22 11kW BOX BV 25/25 2,2kW BOX BV 25/25 3kW BOX BV 25/25 4kW BOX BV 25/25 5,5kW BOX BV 25/25 7,5kW BOX BV 25/25 11kW BOX BV 30/28 2,2kW BOX BV 30/28 3kW BOX BV 30/28 4kW BOX BV 30/28 5,5kW BOX BV 30/28 7,5kW BOX BV 30/28 11kW BOX BV 30/28 15kW 19/19 19/19 19/19 19/19 19/19 25/25 25/25 25/25 25/25 28/28 28/28 28/28 28/28 28/28 33/33 33/33 33/33 33/33 33/33 33/33 39/39 39/39 39/39 39/39 39/39 39/39 39/39 47/47 47/47 47/47 47/47 47/47 47/47 51/51 51/51 51/51 51/51 51/51 51/51 56/56 56/56 56/56 56/56 56/56 56/56 56/56 63/63 63/63 63/63 63/63 63/63 63/63 76/71 76/71 76/71 76/71 76/71 76/71 76/71 1000 1100 1200 1400 1600 900 1000 1200 1300 700 800 900 1000 1200 600 700 800 900 1000 1100 500 600 600 700 800 900 1000 500 500 600 600 700 800 450 500 600 600 700 750 400 400 500 500 600 600 700 350 400 450 450 550 600 250 250 300 350 400 450 450 1,12 1,44 1,94 2,69 3,48 1,94 2,69 3,48 4,74 1,94 2,69 3,48 4,74 6,31 1,94 2,69 3,48 4,74 6,31 8,06 2,69 3,48 4,74 6,31 8,06 11,7 15,2 4,74 6,31 8,06 11,7 15,2 6,31 8,06 11,7 15,2 6,31 8,06 11,7 15,2 8,06 11,7 15,2 8,06 11,7 15,2 - 0,65 0,83 1,12 1,56 2,01 1,12 1,56 2,01 2,75 1,12 1,56 2,01 2,75 3,65 1,12 1,56 2,01 2,75 3,65 5 1,56 2,01 2,75 3,65 5 6,8 8,8 2,75 3,65 5 6,8 8,8 12 3,65 5 6,8 8,8 12 15 3,65 5 6,8 8,8 12 15 20,9 5 6,8 8,8 12 15 20,9 5 6,8 8,8 12 15 20,9 27,9 6,9 6,9 8,6 6,9 8,6 12,02 6,9 8,6 12,02 6,9 8,6 12,02 16,04 28 Rated Power kW 0,18 0,25 0,37 0,55 0,75 0,37 0,55 0,75 1,1 0,37 0,55 0,75 1,1 1,5 0,37 0,55 0,75 1,1 1,5 2,2 0,55 0,75 1,1 1,5 2,2 3 4 1,1 1,5 2,2 3 4 5,5 1,5 2,2 3 4 5,5 7,5 1,5 2,2 3 4 5,5 7,5 11 2,2 3 4 5,5 7,5 11 2,2 3 4 5,5 7,5 11 15 Air flow m3/h Sound dB (A) Weight Kg 1550 1700 1875 2175 2450 2600 3000 3400 3800 3500 4000 4500 5000 5500 4500 5250 5750 6500 7400 8000 6400 7000 8000 8800 10000 11100 12400 10500 11800 13500 15000 16500 18100 13000 14500 16000 18000 20000 22000 15500 18000 20000 22000 24000 26500 30700 21500 23000 25800 28200 31500 36000 27500 31000 34000 37500 42500 47500 54000 62 64 66 69 72 70 73 77 80 68 70 73 77 80 64 67 70 73 76 79 62 64 67 70 74 77 80 67 72 74 77 79 84 74 76 77 80 82 82 73 76 79 82 85 87 90 72 75 77 81 85 88 73 76 77 81 83 86 88 37 37,8 39 41 42,5 51,5 54,5 56 59 55 57 58,5 61,3 64,6 69 71 72,4 75,3 78,6 87 85 86,4 89,3 92,6 101 103 108 122 125,3 133,7 135,7 141 154,5 222 230,5 232,5 237,5 251,5 251,5 250 257 261 265 279 290 316 297 299 304 318 329 349 380 382 387 402 415 426 449 R.R.P. € BOX BV 587,70 605,90 614,80 633,50 677,50 671,30 689,80 743,00 775,70 707,30 725,70 765,90 792,40 833,00 818,20 828,10 851,30 901,40 945,60 996,70 1.117,00 1.175,10 1.207,50 1.294,50 1.353,40 1.387,80 1.453,90 1.493,20 1.520,00 1.567,20 1.602,20 1.668,00 1.841,10 3.049,80 3.259,30 3.367,40 3.501,50 3.860,10 4.115,50 3.281,00 3.516,70 3.603,50 3.737,60 4.108,50 4.490,40 4.929,20 3.976,00 4.074,20 4.252,10 4.603,60 4.952,20 5.635,50 4.368,90 4.560,80 5.068,10 5.285,80 5.431,90 6.342,10 6.888,90 R.R.P. € BOX BV CA 667,20 685,30 694,30 713,00 759,20 757,30 775,70 831,40 864,20 799,40 817,70 861,00 887,30 928,00 916,80 926,50 952,70 1.002,80 1.047,10 1.098,10 1.225,10 1.289,70 1.322,10 1.409,10 1.468,10 1.502,40 1.568,50 1.620,80 1.647,80 1.695,00 1.729,90 1.795,70 1.968,70 - INLINE FANS AND ENERGY SAVING BOX BST Belt driven centrifugal in soundproof cabinet MANUFACTURING FEATURES • B ST range fans assembled in soundproofing cabinets. • Fan assembled on antivibration mountings. • Supplied with motor, pulleys and belts. • Interchangeable panels to allow different fan positions. • Connection gland included. • Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230/400V 50 Hz for three phase, motors up to 4kW and 400/690V 50Hz for higher powers. ACCESSORIES RFS INT PE APPLICATIONS Designed for inline installation, indoor or outdoor assembly, they are suitable for: • Air renewal in buildings and industries. • Industrial and professional kitchen hoods. • Maximum working temperature: 80ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Vertical discharge, circular pipes and blind cover. JE 45 29 INLINE FANS AND ENERGY SAVING THREE PHASE RANGE Model BOX BST 9/4 0,18kW BOX BST 9/4 0,25kW BOX BST 9/4 0,37kW BOX BST 9/4 0,55kW BOX BST 9/4 0,75kW BOX BST 10/5 0,37kW BOX BST 10/5 0,55kW BOX BST 10/5 0,75kW BOX BST 10/5 1,1kW BOX BST 10/5 1,5kW BOX BST 12/6 0,37kW BOX BST 12/6 0,55kW BOX BST 12/6 0,75kW BOX BST 12/6 1,1kW BOX BST 12/6 1,5kW BOX BST 12/6 2,2kW BOX BST 15/7 0,55kW BOX BST 15/7 0,75kW BOX BST 15/7 1,1kW BOX BST 15/7 1,5kW BOX BST 15/7 2,2kW BOX BST 15/7 3kW BOX BST 15/7 4kW BOX BST 18/9 1,1kW BOX BST 18/9 1,5kW BOX BST 18/9 2,2kW BOX BST 18/9 3kW BOX BST 18/9 4kW BOX BST 18/9 5,5kW BOX BST 20/10 1,5kW BOX BST 20/10 2,2kW BOX BST 20/10 3kW BOX BST 20/10 4kW BOX BST 20/10 5,5kW BOX BST 20/10 7,5kW BOX BST 22/11 1,5kW BOX BST 22/11 2,2kW BOX BST 22/11 3kW BOX BST 22/11 4kW BOX BST 22/11 5,5kW BOX BST 22/11 7,5kW BOX BST 22/11 11kW BOX BST 25/13 2,2kW BOX BST 25/13 3kW BOX BST 25/13 4kW BOX BST 25/13 5,5kW BOX BST 25/13 7,5kW BOX BST 25/13 11kW BOX BST 30/14 2,2kW BOX BST 30/14 3kW BOX BST 30/14 4kW BOX BST 30/14 5,5kW BOX BST 30/14 7,5kW BOX BST 30/14 11kW BOX BST 30/14 15kW 30 Max. Curr. (A) 230 400 690 0,73 1,4 2,1 2,45 3,66 1,94 2,69 3,48 4,74 6,31 2,1 2,45 3,66 4,65 5,79 8,26 2,45 3,66 4,65 5,79 8,26 13,2 15,2 4,74 6,31 8,06 11,7 15,2 6,31 8,06 11,7 15,2 6,31 8,06 11,7 15,2 8,06 11,7 15,2 8,06 11,7 15,2 - 0,42 0,81 1,2 1,42 2,12 1,12 1,56 2,01 2,75 3,65 1,2 1,42 2,12 2,69 3,73 4,78 1,42 2,12 2,69 3,73 4,78 7,65 8,8 2,75 3,65 5 6,8 8,8 12 3,65 5 6,8 8,8 12 15 3,65 5 6,8 8,8 12 15 20,9 5 6,8 8,8 12 15 20,9 5 6,8 8,8 12 15 20,9 27,9 6,9 6,9 8,6 6,9 8,6 12,02 6,9 8,6 12,02 6,9 8,6 12,02 16,04 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,18 0,25 0,37 0,55 0,75 0,37 0,55 0,75 1,1 1,5 0,37 0,55 0,75 1,1 1,5 2,2 0,55 0,75 1,1 1,5 2,2 3 4 1,1 1,5 2,2 3 4 5,5 1,5 2,2 3 4 5,5 7,5 1,5 2,2 3 4 5,5 7,5 11 2,2 3 4 5,5 7,5 11 2,2 3 4 5,5 7,5 11 15 1500 1700 1900 2000 2400 2400 2800 3200 3700 3900 2500 2900 3300 3900 4200 4800 3600 4800 6000 6500 7800 8500 9500 5000 6000 7500 8000 9000 10000 11000 13000 14000 15000 16500 19000 11000 15000 16000 18000 20000 22000 23000 16500 19000 21000 24000 26000 29000 16000 18000 22000 25000 30000 33000 36000 72 75 78 80 85 68 74 72 76 82 84 87 82 83 87 88 89 92 79 83 86 88 92 94 77 79 82 85 87 92 71 74 76 78 83 86 74 76 78 82 85 87 45 46 48 50 52 58 59 60 62 63 72 73 74 77 80 85 91 92 95 98 103 106 109 110 114 119 122 125 140 203 208 211 214 227 235 214 219 222 225 238 246 273 251 254 257 270 278 305 325 328 331 344 352 379 398 R.R.P. € 876,90 879,20 906,80 943,80 975,50 970,00 1.008,00 1.040,10 1.120,80 1.214,30 1.066,10 1.105,10 1.136,20 1.223,90 1.299,70 1.370,80 1.215,60 1.253,90 1.341,00 1.428,80 1.523,20 1.634,90 1.894,80 1.531,40 1.611,10 1.727,00 1.824,90 2.104,10 2.466,60 2.424,20 2.514,50 2.629,70 2.863,50 3.205,70 3.591,70 2.572,50 2.714,30 2.780,70 3.082,60 3.379,30 3.746,30 4.496,70 2.864,20 3.018,70 3.280,80 3.581,70 3.931,30 4.718,10 3.344,60 3.452,20 3.714,30 4.015,20 4.483,50 5.242,90 5.807,20 INLINE FANS AND ENERGY SAVING BOX BSTB Belt driven backward centrifugal in soundproof cabinet MANUFACTURING FEATURES • BSTB range fans assembled in soundproof cabinets with insulated panels • Fan assembled on antivibration mountings. • Supplied with motor, pulleys and belts. • Connection gland included. • Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230/400V 50Hz for three phase, motors up to 4kW and 400/690V 50Hz for higher powers. • Industrial and professional kitchen hoods. • Maximum working temperature: 80ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Inlet in the opposite side, vertical inlet, blind inlet panel. • Transmission ratio variation. • Sandwich insulation. APPLICATIONS Designed for inline installation, indoor or outdoor assembly, they are suitable for: • Air renewal in buildings and industries. JE 45 ACCESSORIES Model BOX BSTB 355 0,37kW BOX BSTB 355 0,55kW BOX BSTB 355 0,75kW BOX BSTB 355 1,1kW BOX BSTB 355 1,5kW BOX BSTB 355 2,2kW BOX BSTB 355 3kW BOX BSTB 400 0,55kW BOX BSTB 400 0,75kW BOX BSTB 400 1,1kW BOX BSTB 400 1,5kW BOX BSTB 400 2,2kW BOX BSTB 400 3kW BOX BSTB 400 4kW BOX BSTB 450 0,75kW BOX BSTB 450 1,1kW BOX BSTB 450 1,5kW BOX BSTB 450 2,2kW BOX BSTB 450 3kW BOX BSTB 450 4kW BOX BSTB 450 5,5kW BOX BSTB 450 7,5kW BOX BSTB 500 1,1kW BOX BSTB 500 1,5kW BOX BSTB 500 2,2kW BOX BSTB 500 3kW BOX BSTB 500 4kW BOX BSTB 500 5,5kW BOX BSTB 500 7,5kW BOX BSTB 560 1,5kW BOX BSTB 560 2,2kW BOX BSTB 560 3kW BOX BSTB 560 4kW BOX BSTB 560 5,5kW BOX BSTB 560 7,5kW BOX BSTB 560 11kW BOX BSTB 630 2,2kW BOX BSTB 630 3kW BOX BSTB 630 4kW BOX BSTB 630 5,5kW BOX BSTB 630 7,5kW BOX BSTB 630 11kW BOX BSTB 630 15kW RFS INT PE JE-45 230 Max. Curr. (A) 400 690 Rated Power kW Air flow m3/h 1,94 2,69 3,48 4,74 6,31 8,06 11,7 2,69 3,48 4,74 6,31 8,06 11,7 15,2 3,48 4,74 6,31 8,06 11,7 15,2 4,74 6,31 8,06 11,7 15,2 6,31 8,06 11,7 15,2 8,06 11,7 15,2 - 1,12 1,56 2,01 2,75 3,65 5 6,8 1,56 2,01 2,75 3,65 5 6,8 8,8 2,01 2,75 3,65 5 6,8 8,8 12 15 2,75 3,65 5 6,8 8,8 12 15 3,65 5 6,8 8,8 12 15 20,9 5 6,8 8,8 12 15 20,9 27,9 6,9 8,6 6,9 8,6 6,9 8,6 12,02 6,9 8,6 12,02 16,04 0,37 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 1,5 2,2 3 4 0,75 1,1 1,5 2,2 3 4 5,5 7,5 1,1 1,5 2,2 3 4 5,5 7,5 1,5 2,2 3 4 5,5 7,5 11 2,2 3 4 5,5 7,5 11 15 3370 3850 4330 5050 5530 6010 6980 4350 5020 5360 6030 7370 8040 9460 5990 6490 7490 8490 9490 10490 11490 12980 7490 8850 9530 10890 12260 13620 14980 9550 11290 12160 13020 14760 16500 18230 12720 13990 15260 16540 19080 21630 22900 R.R.P. € 1.696,30 1.724,90 1.741,60 1.745,20 1.797,90 1.827,00 1.850,60 1.897,20 1.908,80 1.915,30 1.961,30 1.998,60 2.029,30 2.095,60 2.173,80 2.179,30 2.226,30 2.248,20 2.296,00 2.355,80 2.511,00 2.674,80 2.489,80 2.539,90 2.558,80 2.604,70 2.663,50 2.817,60 3.001,50 3.239,20 3.216,80 3.279,10 3.411,30 3.368,80 3.707,90 3.899,50 3.583,10 3.673,70 3.779,60 3.742,00 3.417,10 4.304,40 4.598,60 31 INLINE FANS AND ENERGY SAVING Model BOX BSTB 710 3kW BOX BSTB 710 4kW BOX BSTB 710 5,5kW BOX BSTB 710 7,5kW BOX BSTB 710 11kW BOX BSTB 710 15kW BOX BSTB 710 18,5kW BT 230 Max. Curr. (A) 400 690 Rated Power kW Air flow m3/h 11,7 15,2 - 6,8 8,8 12 15 20,9 27,9 33 6,9 8,6 12,02 16,04 18,98 3 4 5,5 7,5 11 15 18,5 18370 18370 20200 22960 25710 27550 31220 R.R.P. € 4.673,90 4.788,10 4.730,50 4.946,50 5.317,80 5.588,60 5.881,20 Backward centrifugal, external rotor motor MANUFACTURING FEATURES • Galvanised steel sheet housing. • Galvanised steel impeller. • External wiring box. • Asynchronous external rotor, IP-44 protection and rated class B insulation according to the DIN 40.050 h1 Standard and ball bearings permanently greased. Manufactured with standard voltages 230V 50Hz. ACCESSORIES REG INT APPLICATIONS Designed for inline installation, they are suitable for: • Air renewal in bathrooms and small closed environments. • Maximum working temperature: 50ºC. PE SINGLE PHASE RANGE Code 250070103 250080103 250090103 250090120 250100103 250120103 250110103 32 Model BT 100 BT 125 BT 150 BT 160 BT 200 BT 250 BT 315 R.P.M. max. Max. Curr. (A) 230 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 2.420 2.420 2.450 2.520 2.550 2.600 2.650 0,35 0,42 0,43 0,60 0,81 0,85 0,80 0,08 0,09 0,09 0,12 0,18 0,19 0,19 240 350 450 660 1.000 1.180 1.500 46 48 48 49 52 56 56 2,6 3 3,2 4,4 4,9 4,2 6 R.R.P. € 109,40 119,00 131,50 137,50 171,20 179,50 235,00 INLINE FANS AND ENERGY SAVING BT-ILF Mixflow, polypropylene casing and impeller MANUFACTURING FEATURES • Housing and turbine made of plastic. • External wiring box. • Standard voltages 230V 50Hz. • Range specially designed to allow fan assembly and disassembly with no need to manage ducts. UNDER REQUEST •BT-ILF TIMER models. APPLICATIONS Designed for inline installation, they are suitable for: • Air renewal in bathrooms and small closed environments. • Maximum working temperature: 50ºC. BT-ILF 100 BT-ILF 4-8 ACCESSORIES REG INT PE SINGLE PHASE RANGE Model BT-ILF 100 BT-ILF 4 BT-ILF 5 BT-ILF 6 BT-ILF 8 Max. Curr. (A) 230 400 R.P.M. max. 2200 2300/1700 2300/1700 2700/2000 2700/2000/1800 KBD-KHB-KTE 0,16 0,18/0,10 0,18/0,10 0,36/0,27 0,34/0,27/0,24 - Rated Power kW Air flow m3/h Sound dB (A) Diameter (mm) Weight Kg 0,025 0,03/0,018 0,03/0,018 0,08/0,06 0,085/0,065/0,055 130 270/190 365/250 595/420 910/820/720 24 30/24 32/26 33/27 39/34/32 100 100 125 150 200 1,2 2,1 2,1 3,2 4,5 R.R.P. € 74,60 88,00 118,40 156,10 215,30 Staircase pressurisation kit Set consisting of a differential pressure transmitter (DPS) with a frequency speed controller (RFS), and a supplying unit (Box BD, Box HB or HMTE IMP). Used to pressurize staircases and escape routes. It automatically regulates the airflow to keep a 50 Pa differential pressure, according to the UNE-EN 12101-6 standard. THREE PHASE RANGE Model KBD KHB-1 KHB-2 KHB-3 KTE-1 KTE-2 Differential pressure transmitter Frequency speed controller Ventilation unit Air flow m3/h Sound dB (A) DPS DPS DPS DPS DPS DPS RFS 2-2 RFS 2-1/2 RFS 2-1 RFS 2-2 RFS 2-1 RFS 2-2 BOX BD 12/12 T6 1,1kW BOX HB 45 T4 0,37kW BOX HB 56 T4 0,75kW BOX HB 63 T4 1,1kW HMTE IMP 56 T4 0,55kW HMTE IMP 63 T4 1,1kW 6750 7500 11800 15800 9000 12300 58 67 70 71 72 74 R.R.P. € 1.401,90 984,30 1.105,50 1.320,50 1.889,40 2.297,30 33 ENERGY SAVING CMV Controlled Mechanical Ventilation EAA Self-regulable air inlet. Diffuser and external cover on the facade included. Model R.R.P. € EAA 15 EAA 22 EAA 30 EAA 45 5,80 5,80 5,80 6,20 EAA S Acoustic and self-regulated air inlet with diffuser, external cover on the facade and noise attenuator accessory included. Model R.R.P. € EAA S 22 EAA S 30 EAA S 45 26,10 26,10 28,60 EAA SH Acoustic and moisture-regulated air inlet. Air-flow from 7 to 40 m3/h depending on the degree of humidity. Diffuser, external cover on the facade and noise attenuator accessory included. Model R.R.P. € EAA SH 40 69,00 BEA S / BEA C Self-regulated extraction inlet that allows a constant extraction of air. BEA S provides a fixed air-flow extraction, suitable for bathrooms. BEA C provides a permanent air-flow extraction that adds an additional aif-flow with external action; suitable for kitchens and small environments. Model BEA S 15 BEA S 30 BEA S 45 BEA S 60 BEA S 75 BEA S 90 BEA S 120 BEA S 150 BEA C 20/75 BEA C 30/90 BEA C 45/105 BEA C 45/120 BEA C 45/135 MGJ 125 (hose) MGP 125 (hose) MGP 125/80 (hose) Model R.R.P. € BE 80 BE 125 8,50 11,00 BIRM Manual self-regulated extraction inlet through a central screw. Manufactured in painted steel sheet. Suitable for community housing. BEH 5/40 BEH 5/45 BEH 10/40 BEH 14/45 BEH 15/100 BEH 15/50 BEH 15/75 BIRM 100 BIRM 125 BIRM 160 BIRM 200 R.R.P. € 10,60 13,10 16,50 23,60 BERM Manual self-regulated extraction inlet through a central screw. Manufactured in painted steel sheet. Suitable for community housing. Model BERM 100 BERM 125 BERM 160 BERM 200 34 R.R.P. € 22,90 27,60 34,00 44,20 R.R.P € 77,50 77,50 77,50 77,50 88,40 83,90 86,80 BEIRM Manual self-regulated extraction inlet through a central screw. Manufactured in plastic. Suitable for community housing. Model Model 15,90 15,90 15,90 15,90 15,90 15,90 29,90 29,90 31,70 31,70 31,70 31,70 31,70 4,70 7,00 7,00 BEH Moisture-regulated extraction air inlet. Model BE Plastic extraction inlet for houses. R.R.P € BEIRM 80 BEIRM 100 BEIRM 125 BEIRM 160 BEIRM 200 R.R.P. € 11,60 15,20 16,00 22,30 29,90 ENERGY SAVING CFR Circular constant flow regulator with hose and self-regulating system composed of a hatch and a regulatory spring that allows a constant flow rate with pressure variations between 50 and 200 Pa. Model CFR 80/15 CFR 80/30 CFR 80/45 CFR 100/15 CFR 100/30 CFR 100/45 CFR 100/60 CFR 100/75 CFR 100/90 CFR 125/15 CFR 125/30 CFR 125/45 CFR 125/60 CFR 125/75 CFR 125/90 CFR 125/120 CFR 125/150 CFR 125/180 CFR 160/120 CFR 160/150 R.R.P. € Model 16,40 16,40 16,40 19,90 19,90 19,90 19,90 19,90 19,90 22,50 22,50 22,50 22,50 22,50 22,50 22,50 22,50 22,50 36,10 36,10 CFR 160/180 CFR 160/210 CFR 160/240 CFR 160/270 CFR 160/300 CFR 200/210 CFR 200/240 CFR 200/270 CFR 200/300 CFR 200/350 CFR 200/400 CFR 200/450 CFR 200/500 CFR 250/350 CFR 250/500 CFR 250/550 CFR 250/600 CFR 250/650 CFR 250/700 R.R.P. € 36,10 36,10 36,10 36,10 36,10 50,20 50,20 50,20 50,20 50,20 50,20 50,20 50,20 64,90 64,90 64,90 64,90 64,90 64,90 OKTOPUS CMV extraction box. Model OKTOPUS R.R.P. € 144,30 BOX SIRIUS 400ºC 1/2h CMV box suitable for community housings and small environments from the tertiary sector. Model BOX SIRIUS 600 BOX SIRIUS 1200 R.R.P. € 595,50 751,20 BOX ANTARES 400ºC 1/2h CMV direct driven box. Model BOX ANTARES 2200 BOX ANTARES 2200 IN R.R.P. € 1.288,30 1.327,20 BOX VEGA BP 400ºC 1/2h CMV box suitable for community housings and small environments from the tertiary sector. Quick release system. Model BOX VEGA BP 3400 BOX VEGA BP 4500 BOX VEGA BP 7500 BOX VEGA BP 9800 BOX VEGA BP 3400 IN BOX VEGA BP 4500 IN BOX VEGA BP 7500 IN BOX VEGA BP 9800 IN R.R.P. € 1.434,80 1.733,70 2.042,90 2.474,60 1.631,80 2.007,40 2.318,90 2.693,30 35 ENERGY SAVING RCIB Heat recovery unit MANUFACTURING FEATURES • Chassis: extruded anodized aluminum profiles with reinforced corners made of polyamide. • Casing: detachable sandwich panels. Outside lateral panel steel with white lacquered coating, 25 mm thickness rock wool (Fire M0), thermal and acoustic insulation, and inside panel made of galvanized steel. • Fixing system through threaded fittings on the structure profiles. • Fans: double inlet centrifugal fans with forward impeller and direct belt-driven motor. Mounted and fixed to the outlet panels for an easy access wiring operations and maintenance. • Exchanger: Eurovent certified crossed flow exchanger cell made of aluminium, removable from the bottom and top panels. • Efficiency up to 60% depending on the models and conditions of use. • Condensates tray: Condensates tray in galvanized steel with a plastic drain outside. • Filters: Two filtration levels with low pressure drop filters G4 + F7 in outlet and return (F7 + F9 option in outlet) mounted on slides horizontally or vertically removable inspection door from the side, top or bottom. • Motorization: four speed 230v/50Hz II motor in RCIB 600 and RCIB 900 models. Three speed motor in RCIB 1900 and RCIB 2800 models. 400V/50Hz III motor in RCIB 3700 and RCIB 2800 models. ACCESSORIES FILTERS INT INT 3V APPLICATIONS Energy recovery units for ventilation installations according to the EN-13779 requirements. Advantages: • It reduces the consumption with a thermal recovery efficiency up to 60% • Easy accessibility and maintenance of components. • Double-panel structure with M0 25mm rock wool insulation. • Two filtration levels: G4 + F7 in outlet and return. • Safety switch and deportable connection box. UNDER REQUEST • Partial exterior motorizable bypass. • Heat electrical coil with heat resistors with dissipation fins. 230VII supply, with double thermal protection with automatic reset at 75°C, and manual reset at a 115°C. • Hot water coil with copper tubes and aluminum fins. Supplied with no-freeze safety thermostat with automatic reset at adjustable temperature. • Sandwich panels with 50mm thickness M0 insulation. DPS SINGLE PHASE RANGE Code 300727800 300727900 300728000 300728100 - 36 Model RCIB H 600 RCIB H 900 RCIB H 1900 RCIB H 2800 RCIB H 600 BP RCIB H 900 BP RCIB H 1900 BP RCIB H 2800 BP RCIB V 600 RCIB V 900 RCIB V 1900 RCIB V 2800 RCIB V 600 BP RCIB V 900 BP RCIB V 1900 BP RCIB V 2800 BP RCIB WC H 600 RCIB WC H 900 RCIB WC H 1900 RCIB WC H 2800 RCIB EC H 600 RCIB EC H 900 Absorbed Max. Current (A) Motor power W Motor polarity Air flow m3/h Sound dB (A) Insulation class Protection index Weight Kg 2 x 0,86 2 x 1,55 2 x 2,8 2 x 4,7 2 x 0,86 2 x 1,55 2 x 2,8 2 x 4,7 2 x 0,86 2 x 1,55 2 x 2,8 2 x 4,7 2 x 0,86 2 x 1,55 2 x 2,8 2 x 4,7 2 x 0,86 2 x 1,55 2 x 2,8 2 x 4,7 2 x 0,86 2 x 1,55 2 x 195 2 x 355 2 x 375 2 x 550 2 x 195 2 x 355 2 x 375 2 x 550 2 x 195 2 x 355 2 x 375 2 x 550 2 x 195 2 x 355 2 x 375 2 x 550 2 x 195 2 x 355 2 x 375 2 x 550 2 x 195 2 x 355 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 590 890 1890 2800 590 890 1890 2800 590 890 1890 2800 590 890 1890 2800 590 890 1890 2800 590 890 50 52 53 56 50 52 53 56 50 52 53 56 50 52 53 56 50 52 53 56 50 52 F F B F F F B F F F B F F F B F F F B F F F 20 20 44 44 20 20 44 44 20 20 44 44 20 20 44 44 20 20 44 44 20 20 34 70 130 150 34 70 130 150 34 70 130 150 34 70 130 150 34 70 130 150 34 70 R.R.P. € 2.643,40 2.941,20 3.783,60 5.128,50 2.904,00 3.206,50 4.058,20 5.431,00 2.806,30 3.122,70 4.007,00 5.445,00 3.085,50 3.406,60 4.304,80 5.770,80 3.262,30 3.509,00 4.518,90 5.915,00 2.810,90 3.141,30 ENERGY SAVING Code Model - Absorbed Max. Current (A) Motor power W Motor polarity Air flow m3/h Sound dB (A) Insulation class Protection index Weight Kg 2 x 2,8 2 x 4,7 2 x 0,86 2 x 1,55 2 x 2,8 2 x 4,7 2 x 0,86 2 x 1,55 2 x 2,8 2 x 4,7 2 x 0,86 2 x 1,55 2 x 2,8 2 x 4,7 2 x 0,86 2 x 1,55 2 x 2,8 2 x 4,7 2 x 0,86 2 x 1,55 2 x 2,8 2 x 4,7 2 x 0,86 2 x 1,55 2 x 2,8 2 x 4,7 2 x 375 2 x 550 2 x 195 2 x 355 2 x 375 2 x 550 2 x 195 2 x 355 2 x 375 2 x 550 2 x 195 2 x 355 2 x 375 2 x 550 2 x 195 2 x 355 2 x 375 2 x 550 2 x 195 2 x 355 2 x 375 2 x 550 2 x 195 2 x 355 2 x 375 2 x 550 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 1890 2800 590 890 1890 2800 590 890 1890 2800 590 890 1890 2800 590 890 1890 2800 590 890 1890 2800 590 890 1890 2800 53 56 50 52 53 56 50 52 53 56 50 52 53 56 50 52 53 56 50 52 53 56 50 52 53 56 B F F F B F F F B F F F B F F F B F F F B F F F B F 44 44 20 20 44 44 20 20 44 44 20 20 44 44 20 20 44 44 20 20 44 44 20 20 44 44 130 150 34 70 130 150 34 70 130 150 34 70 130 150 34 70 130 150 34 70 130 150 34 70 130 150 Motor polarity Air flow m3/h Sound dB (A) Insulation class 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 4 Poles 3700 5100 3700 5100 3700 5100 3700 5100 3700 5100 3700 5100 3700 5100 3700 5100 3700 5100 3700 5100 3700 5100 3700 5100 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 F F F F F F F F F F F F F F F F F F F F F F F F RCIB EC H 1900 RCIB EC H 2800 RCIB WC H 600 BP RCIB WC H 900 BP RCIB WC H 1900 BP RCIB WC H 2800 BP RCIB EC H 600 BP RCIB EC H 900 BP RCIB EC H 1900 BP RCIB EC H 2800 BP RCIB WC V 600 RCIB WC V 900 RCIB WC V 1900 RCIB WC V 2800 RCIB EC V 600 RCIB EC V 900 RCIB EC V 1900 RCIB EC V 2800 RCIB WC V 600 BP RCIB WC V 900 BP RCIB WC V 1900 BP RCIB WC V 2800 BP RCIB EC V 600 BP RCIB EC V 900 BP RCIB EC V 1900 BP RCIB EC V 2800 BP R.R.P. € 4.109,30 5.570,70 3.536,90 3.783,60 4.812,10 6.231,50 3.076,20 3.411,30 4.388,60 5.877,80 3.471,80 3.727,70 4.798,10 6.292,00 2.983,10 3.336,80 4.356,00 5.919,70 3.765,00 4.025,60 5.114,60 6.631,70 3.267,00 3.625,30 4.663,20 6.250,10 THREE PHASE RANGE Code Model 300728200 300728300 - RCIB H 3700 RCIB H 5100 RCIB V 3700 RCIB V 5100 RCIB H 3700 BP RCIB H 5100 BP RCIB V 3700 BP RCIB V 5100 BP RCIB WC H 3700 RCIB WC H 5100 RCIB EC H 3700 RCIB EC H 5100 RCIB WC H 3700 BP RCIB WC H 5100 BP RCIB EC H 3700 BP RCIB EC H 5100 BP RCIB WC V 3700 RCIB WC V 5100 RCIB EC V 3700 RCIB EC V 5100 RCIB WC V 3700 BP RCIB WC V 5100 BP RCIB EC V 3700 BP RCIB EC V 5100 BP H BP V EC WC Absorbed Max. Motor power Current (A) W 2 x 3,2 2 x 5,4 2 x 3,2 2 x 5,4 2 x 3,2 2 x 5,4 2 x 3,2 2 x 5,4 2 x 3,2 2 x 5,4 2 x 3,2 2 x 5,4 2 x 3,2 2 x 5,4 2 x 3,2 2 x 5,4 2 x 3,2 2 x 5,4 2 x 3,2 2 x 5,4 2 x 3,2 2 x 5,4 2 x 3,2 2 x 5,4 2 x 750 2 x 1500 2 x 750 2 x 1500 2 x 750 2 x 1500 2 x 750 2 x 1500 2 x 750 2 x 1500 2 x 750 2 x 1500 2 x 750 2 x 1500 2 x 750 2 x 1500 2 x 750 2 x 1500 2 x 750 2 x 1500 2 x 750 2 x 1500 2 x 750 2 x 1500 Protection Weight index Kg 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 R.R.P. € 6.403,70 6.836,50 6.790,00 7.255,30 6.724,80 7.162,30 7.134,30 7.609,00 7.329,80 7.758,00 6.957,50 7.502,00 7.664,90 8.107,00 7.287,90 7.846,40 7.785,90 8.251,30 7.385,70 7.972,00 8.148,90 8.623,60 7.744,00 8.344,30 HORIZONTAL BYPASS VERTICAL ELECTRICAL COIL WATER COIL 37 SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE HBF-HBFX Axial fan 400ºC/2h MANUFACTURING FEATURES • Axial fan with circular reinforced frame. • Modular motor-impeller assembly. • Cast aluminium impeller with variable pitch angle. Epoxy powder finishing coat. • Standard asynchronous squirrel cage motor with IP-55 protection and Class H insulation certified 400ºC/2h. Standard voltages 230/400V 50Hz in three phase, motors up to 4kW and 400/690V 50Hz for higher powers. UNDER REQUEST • B Form impeller (air flow from impeller to motor), 100% reversible impeller (5% additional cost). • 300ºC/2h motor. • ATEX models (HBFX). 10% additional cost. HBF APPLICATIONS Designed for wall or duct installation, they are suitable for: • Smoke emergency exhaust with motor inside the hazardous area. • Maximum working temperature: 60ºC. INSIDE HBFX ACCESSORIES 38 RFS INT PE MC HB SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE THREE PHASE RANGE Model HBF / HBFX R.P.M. max. HBF 40 T4 0,55kW HBF 40 T4 0,75kW HBF 45 T4 0,55kW HBF 45 T4 0,75kW HBF 45 T6 0,55kW HBF 50 T4 0,55kW HBF 50 T4 0,75kW HBF 50 T6 0,55kW HBF 56 T4 0,75kW HBF 56 T4 1,1kW HBF 56 T4 1,5kW HBF 56 T6 0,55kW HBF 63 T4 0,75kW HBF 63 T4 1,1kW HBF 63 T4 1,5kW HBF 63 T4 2,2kW HBF 63 T4 3kW HBF 63 T6 0,55kW HBF 63 T6 0,75kW HBF 71 T4 1,1kW HBF 71 T4 1,5kW HBF 71 T4 2,2kW HBF 71 T4 3kW HBF 71 T6 0,55kW HBF 71 T6 0,75kW HBF 71 T6 1,1kW HBF 80 T4 2,2kW HBF 80 T4 3kW HBF 80 T4 4kW HBF 80 T6 0,75kW HBF 80 T6 1,1kW HBF 80 T6 1,5kW HBF 80 T6 2,2kW HBF 90 T4 3kW HBF 90 T4 4kW HBF 90 T4 5,5kW HBF 90 T4 7,5kW HBF 90 T6 1,5kW HBF 90 T6 2,2kW HBF 90 T6 3kW HBF 100 T4 5,5kW HBF 100 T4 7,5kW HBF 100 T4 11kW HBF 100 T4 15kW HBF 100 T6 2,2kW HBF 100 T6 3kW HBF 100 T6 4kW HBF 125 T4 11kW HBF 125 T4 15kW HBF 125 T4 18,5kW HBF 125 T4 22kW HBF 125 T6 3kW HBF 125 T6 4kW HBF 125 T6 7,5kW HBF 125 T6 11kW 1400 1415 1400 1415 920 1400 1415 920 1415 1430 1435 920 1415 1430 1435 1455 1455 920 920 1430 1435 1455 1455 920 920 920 1455 1455 1455 920 920 960 960 1455 1455 1455 1455 960 960 945 1455 1455 1455 1455 960 945 945 1455 1455 1465 1465 945 945 968 966 Max. Curr. (A) 230 400 690 2,69 3,46 2,69 3,46 2,6 2,69 3,46 2,6 3,46 4,33 5,89 2,6 3,46 4,33 5,89 7,97 10,74 2,6 3,46 4,33 5,89 7,97 10,74 2,6 3,46 5,11 7,97 10,74 3,46 5,11 6,41 9,01 10,74 6,41 9,01 12,12 9,01 12,12 12,12 - 1,56 2 1,56 2 1,5 1,56 2 1,5 2 2,5 3,4 1,5 2 2,5 3,4 4,6 6,2 1,5 2 2,5 3,4 4,6 6,2 1,5 2 2,95 4,6 6,2 8,2 2 2,95 3,7 5,2 6,2 8,2 10,8 14,5 3,7 5,2 7 10,8 14,5 20,9 27,9 5,2 7 9,3 20,9 27,9 35 40,8 7 9,3 16 23 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg HBF 0,55 0,75 0,55 0,75 0,55 0,55 0,75 0,55 0,75 1,1 1,5 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 2,2 3 4 0,75 1,1 1,5 2,2 3 4 5,5 7,5 1,5 2,2 3 5,5 7,5 11 15 2,2 3 4 11 15 18,5 22 3 4 7,5 11 4500 4700 7300 7500 5200 9200 10065 6000 12650 13970 15600 10170 14080 16500 18620 21010 23430 12430 13860 20570 22000 23870 27060 15400 17480 19640 29700 34980 38700 23100 25840 28600 30620 37540 44320 49370 55040 30580 35390 39910 53080 61590 66450 71510 37740 45690 51450 82600 89000 97300 103700 50000 55800 73600 88600 63 64 67 68 56 69 70 60 74 75 76 63 72 73 74 75 76 63 65 78 79 81 82 65 67 68 83 84 85 70 73 74 75 87 89 90 91 78 79 80 92 93 94 95 82 83 84 94 94 95 95 80 81 83 85 31 32 32 33 39 33 34 33 35 34 36 38 36 39 41 50 52 35 42 44 46 56 58 45 48 49 65 67 72 56 58 64 69 74 79 95 106 71 76 100 103 133 148 80 104 112 115 237 247 275 287 180 194 188 194 4,73 4,73 6,24 8,37 6,24 8,37 12,07 16,11 5,37 12,07 16,11 20,21 23,56 5,37 9,24 13,28 R.R.P. € HBF 400ºC/2h 1.218,90 1.228,30 1.233,50 1.246,60 1.368,10 1.271,30 1.282,10 1.389,90 1.313,60 1.404,60 1.596,50 1.530,50 1.375,30 1.451,00 1.608,10 1.804,70 2.165,30 1.507,10 1.661,70 1.508,30 1.666,00 1.890,70 2.251,30 1.595,90 1.686,00 1.694,10 1.987,60 2.347,90 2.492,80 1.719,90 1.944,30 2.276,20 2.397,10 2.418,30 2.562,00 2.907,60 3.142,30 2.270,00 2.390,90 2.960,60 3.169,10 3.403,70 5.581,10 7.504,30 2.576,00 3.310,50 3.632,50 7.647,30 8.090,50 9.853,90 10.278,30 5.815,60 6.121,30 7.590,70 8.981,60 THREE PHASE RANGE 2 SPEEDS Model HBF / HBFX HBF 40 T4/T8 0,75-0,15kW HBF 45 T4/T8 0,75-0,15kW HBF 50 T4/T8 0,75-0,15kW HBF 56 T4/T8 0,75-0,15kW HBF 56 T4/T8 1,1-0,18kW HBF 56 T4/T8 1,5-0,25kW HBF 63 T4/T8 0,75-0,15kW HBF 63 T4/T8 1,1-0,18kW HBF 63 T4/T8 1,5-0,25kW HBF 63 T4/T8 2,2-0,37kW HBF 63 T4/T8 3-0,55kW HBF 71 T4/T8 1,1-0,18kW HBF 71 T4/T8 1,5-0,25kW HBF 71 T4/T8 2,2-0,37kW HBF 71 T4/T8 3-0,55kW HBF 80 T4/T8 2,2-0,37kW HBF 80 T4/T8 3-0,55kW HBF 80 T4/T8 4-0,75kW R.P.M. max. Max. Curr. (A) 400V Rated Power kW Air flow m3/h Sound dB (A) 1420/710 1420/710 1420/710 1420/710 1430/715 1430/715 1420/710 1430/715 1430/715 1430/715 1445/725 1430/715 1430/715 1430/715 1445/725 1430/715 1445/725 1450/730 2,2/0,85 2,2/0,85 2,2/0,85 2,2/0,85 2,85/0,85 3,75/1,15 2,2/0,85 2,85/0,85 3,75/1,15 5,1/1,6 6,5/2,55 2,85/0,85 3,75/1,15 5,1/1,6 6,5/2,55 5,1/1,6 6,5/2,55 8,8/3,3 0,75/0,15 0,75/0,15 0,75/0,15 0,75/0,15 1,1/0,18 1,5/0,25 0,75/0,15 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 2,2/0,37 3/0,55 4/0,75 4700/2350 7500/3750 8500/4250 12650/6325 13970/6985 15600/7800 14080/7040 16500/8250 18620/9310 21010/10505 23430/11715 20570/10285 22000/11000 23870 / 11935 27060/13530 29700 / 14850 34980/17490 38700 / 19350 67/50 68/51 70/52 73/55 75/57 76/58 72/54 73/55 74/56 75/57 76/58 78/60 79/61 81/63 82/64 83/65 84/66 85/67 R.R.P. € HBF 400ºC/2h 1.545,70 1.555,70 1.585,30 1.616,80 1.714,60 1.962,10 1.683,50 1.781,90 2.031,30 2.273,70 2.634,30 1.890,70 2.140,00 2.382,50 2.743,40 2.478,80 2.839,30 3.200,20 39 SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE Model HBF / HBFX HBF 90 T4/T8 3-0,55kW HBF 90 T4/T8 4-0,75kW HBF 90 T4/T8 5,5-1,1kW HBF 90 T4/T8 7,5-1,5kW HBF 100 T4/T8 5,5-1,1kW HBF 100 T4/T8 7,5-1,5kW HBF 100 T4/T8 10-2kW HBF 100 T4/T8 14-3kW HBF 125 T4/T8 10-2kW HBF 125 T4/T8 14-3kW HBF 125 T4/T8 16,5-3,3kW HBF 125 T4/T8 20-4kW BOX HBF BOX HBFX R.P.M. max. Max. Curr. (A) 400V Rated Power kW Air flow m3/h Sound dB (A) 1445/725 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 6,5/2,55 8,8/3,3 11,1/3,5 16,5/5,2 11,1/3,5 15/4,7 16,5/5,2 29/7 16,5/5,2 29/7 35,4/7,9 42,3/8,2 3/0,55 4/0,75 5,5/1,1 10/2 5,5/1,1 7,5/1,5 10/2 14/3 10/2 14/3 16,5/3,3 20/4 37540/18770 44320 / 22160 49370/24685 55040 / 27520 53080/26540 61590/30795 66450/33225 71510/35755 82600/41300 89000/44500 97300/48650 103700/51850 87/69 89/71 90/72 94/76 92/74 93/75 94/76 95/77 95/77 96/78 96/78 97/79 R.R.P. € HBF 400ºC/2h 2.907,60 3.266,00 3.689,50 4.289,40 3.980,90 4.555,50 7.288,60 8.562,60 9.263,60 10.400,90 10.966,70 17.643,30 Axial fan in soundproof cabinet 400ºC/2h MANUFACTURING FEATURES • BOX: Manufactured in galvanised steel sheet with thermalproofing. Soundproof cabinets with Flexiroll Pol Na 30 anthracite grey M1 fire resistance insulated panels. Removable panels for easy motor access and fan maintenance. • Internal fan: HBF, axial fan with circular reinforced frame. Modular motor-impeller assembly. Cast aluminium impeller with variable pitch angle. Epoxy powder finishing coat. BOX HBF • Standard asynchronous squirrel-cage motor with IP-55 protection and Class H insulation certified 400ºC/2H. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. APPLICATIONS Designed for wall or duct installation, they are suitable for: • Smoke emergency exhaust with motor inside the hazardous area. • Cabinet design simplifies installation in rectangular duct systems. • Maximum working temperature: 60ºC. UNDER REQUEST • B form, 100% reversible impeller. 5% additional cost. • 300ºC/2h motor. • ATEX models (BOX HBFX). 10% additional cost. INSIDE BOX HBFX ACCESSORIES RFS INT PE THREE PHASE RANGE Max. Curr. (A) Model BOX HBF / BOX HBFX R.P.M. max. 230 400 BOX HBF 40 T4 0,55kW BOX HBF 40 T4 0,75kW BOX HBF 45 T4 0,55kW BOX HBF 45 T4 0,75kW BOX HBF 45 T6 0,55kW BOX HBF 50 T4 0,55kW BOX HBF 50 T4 0,75kW BOX HBF 50 T6 0,55kW BOX HBF 56 T4 0,75kW BOX HBF 56 T4 1,1kW BOX HBF 56 T4 1,5kW BOX HBF 56 T6 0,55kW BOX HBF 63 T4 0,75kW BOX HBF 63 T4 1,1kW BOX HBF 63 T4 1,5kW BOX HBF 63 T4 2,2kW 1400 1415 1400 1415 920 1400 1415 920 1415 1430 1435 920 1415 1430 1435 1455 2,69 3,46 2,69 3,46 2,6 2,69 3,46 2,6 3,46 4,33 5,89 2,6 3,46 4,33 5,89 7,97 1,56 2 1,56 2 1,5 1,56 2 1,5 2 2,5 3,4 1,5 2 2,5 3,4 4,6 40 690 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg BOX HBF 0,55 0,75 0,55 0,75 0,55 0,55 0,75 0,55 0,75 1,1 1,5 0,55 0,75 1,1 1,5 2,2 4500 4700 7300 7500 5200 9200 10065 11330 12650 13970 15600 10170 14080 16500 18620 21010 60 59 60 61 50 66 67 55 71 72 73 60 69 70 71 72 56 57 64 65 64 64 65 67 75 75 77 74 77 77 79 92 R.R.P. € BOX HBF 400ºC/2h 1.770,30 1.790,20 1.798,10 1.811,00 1.938,80 1.801,30 1.818,40 1.941,00 1.925,90 2.053,70 2.256,90 2.186,90 2.010,00 2.090,00 2.256,50 2.463,90 SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE Max. Curr. (A) Model BOX HBF / BOX HBFX R.P.M. max. 230 400 690 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg BOX HBF BOX HBF 63 T4 3kW BOX HBF 63 T6 0,55kW BOX HBF 63 T6 0,75kW BOX HBF 71 T4 1,1kW BOX HBF 71 T4 1,5kW BOX HBF 71 T4 2,2kW BOX HBF 71 T4 3kW BOX HBF 71 T6 0,55kW BOX HBF 71 T6 0,75kW BOX HBF 71 T6 1,1kW BOX HBF 80 T4 2,2kW BOX HBF 80 T4 3kW BOX HBF 80 T4 4kW BOX HBF 80 T6 0,75kW BOX HBF 80 T6 1,1kW BOX HBF 80 T6 1,5kW BOX HBF 80 T6 2,2kW BOX HBF 90 T4 3kW BOX HBF 90 T4 4kW BOX HBF 90 T4 5,5kW BOX HBF 90 T4 7,5kW BOX HBF 90 T6 1,5kW BOX HBF 90 T6 2,2kW BOX HBF 90 T6 3kW BOX HBF 100 T4 5,5kW BOX HBF 100 T4 7,5kW BOX HBF 100 T4 11kW BOX HBF 100 T4 15kW BOX HBF 100 T6 2,2kW BOX HBF 100 T6 3kW BOX HBF 100 T6 4kW BOX HBF 125 T4 11kW BOX HBF 125 T4 15kW BOX HBF 125 T4 18,5kW BOX HBF 125 T4 22kW BOX HBF 125 T6 3kW BOX HBF 125 T6 4kW BOX HBF 125 T6 7,5kW BOX HBF 125 T6 11kW 1455 920 920 1430 1435 1455 1455 920 920 920 1455 1455 1455 920 920 960 960 1455 1455 1455 1455 960 960 945 1455 1455 1455 1455 960 945 945 1455 1455 1465 1465 945 945 968 966 10,74 2,6 3,46 4,33 5,89 7,97 10,74 2,6 3,46 5,11 7,97 10,74 3,46 5,11 6,41 9,01 10,74 6,41 9,01 12,12 9,01 12,12 12,12 - 6,2 1,5 2 2,5 3,4 4,6 6,2 1,5 2 2,95 4,6 6,2 8,2 2 2,95 3,7 5,2 6,2 8,2 10,8 14,5 3,7 5,2 7 10,8 14,5 20,9 27,9 5,2 7 9,3 20,9 27,9 35 40,8 7 9,3 16 23 4,73 4,73 6,24 8,37 6,24 8,37 12,07 16,11 5,37 12,07 16,11 20,21 23,56 5,37 9,24 13,28 3 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 2,2 3 4 0,75 1,1 1,5 2,2 3 4 5,5 7,5 1,5 2,2 3 5,5 7,5 11 15 2,2 3 4 11 15 18,5 22 3 4 7,5 11 23430 12430 13860 20570 22000 23870 27060 15400 17480 19640 29700 34980 38700 23100 25840 28600 30620 37540 44320 49370 55040 30580 35390 39910 53080 61590 66450 71510 37740 45690 51450 82600 89000 97300 103700 50000 55800 64800 73600 73 61 62 75 76 77 78 63 64 65 80 81 82 67 70 71 72 84 85 87 88 75 76 77 89 89 90 91 79 80 81 91 91 92 92 77 78 80 82 103 80 80 98 100 113 125 98 98 105 119 130 130 112 115 117 129 160 160 191 195 147 159 188 197 201 254 264 165 194 211 302 312 340 352 245 259 263 259 R.R.P. € BOX HBF 400ºC/2h 2.912,00 2.150,00 2.313,70 2.278,70 2.445,00 2.682,80 3.064,10 2.285,40 2.466,50 2.519,10 2.711,70 3.092,40 3.244,90 2.495,00 2.503,70 2.853,60 3.021,10 3.465,40 3.617,50 3.995,00 4.241,50 3.212,80 3.447,40 4.049,90 4.107,00 4.355,50 6.851,50 7.808,70 3.565,50 4.168,30 4.508,90 8.820,10 9.263,30 11.026,80 11.451,10 6.988,50 7.294,20 8.763,50 10.154,50 THREE PHASE RANGE 2 SPEEDS Model BOX HBF / BOX HBFX BOX HBF 40 T4/T8 0,75-0,15kW BOX HBF 45 T4/T8 0,75-0,15kW BOX HBF 50 T4/T8 0,75-0,15kW BOX HBF 56 T4/T8 0,75-0,15kW BOX HBF 56 T4/T8 1,1-0,18kW BOX HBF 56 T4/T8 1,5-0,25kW BOX HBF 63 T4/T8 0,75-0,15kW BOX HBF 63 T4/T8 1,1-0,18kW BOX HBF 63 T4/T8 1,5-0,25kW BOX HBF 63 T4/T8 2,2-0,37kW BOX HBF 63 T4/T8 3-0,55kW BOX HBF 71 T4/T8 1,1-0,18kW BOX HBF 71 T4/T8 1,5-0,25kW BOX HBF 71 T4/T8 2,2-0,37kW BOX HBF 71 T4/T8 3-0,55kW BOX HBF 80 T4/T8 2,2-0,37kW BOX HBF 80 T4/T8 3-0,55kW BOX HBF 80 T4/T8 4-0,75kW BOX HBF 90 T4/T8 3-0,55kW BOX HBF 90 T4/T8 4-0,75kW BOX HBF 90 T4/T8 5,5-1,1kW BOX HBF 90 T4/T8 7,5-1,5kW BOX HBF 100 T4/T8 5,5-1,1kW BOX HBF 100 T4/T8 7,5-1,5kW BOX HBF 100 T4/T8 10-2kW BOX HBF 100 T4/T8 14-3kW BOX HBF 125 T4/T8 10-2kW BOX HBF 125 T4/T8 14-3kW BOX HBF 125 T4/T8 16,5-3,3kW BOX HBF 125 T4/T8 20-4kW R.P.M. max. Max. Curr. (A) 400V Rated Power kW Air flow m3/h Sound dB (A) 1420/710 1420/710 1420/710 1420/710 1430/715 1430/715 1420/710 1430/715 1430/715 1430/715 1445/725 1430/715 1430/715 1430/715 1445/725 1430/715 1445/725 1450/730 1445/725 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 2,2/0,85 2,2/0,85 2,2/0,85 2,2/0,85 2,85/0,85 3,75/1,15 2,2/0,85 2,85/0,85 3,75/1,15 5,1/1,6 6,5/2,55 2,85/0,85 3,75/1,15 5,1/1,6 6,5/2,55 5,1/1,6 6,5/2,55 8,8/3,3 6,5/2,55 8,8/3,3 11,1/3,5 15/4,7 11,1/3,5 15/4,7 16,5/5,2 29/7 16,5/5,2 29/7 35,4/7,9 42,3/8,2 0,75/0,15 0,75/0,15 0,75/0,15 0,75/0,15 1,1/0,18 1,5/0,25 0,75/0,15 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 2,2/0,37 3/0,55 4/0,75 3/0,55 4/0,75 5,5/1,1 7,5/1,5 5,5/1,1 7,5/1,5 10/2 14/3 10/2 14/3 16,5/3,3 20/4 4700/2350 7500/3750 8500/4250 12650/6325 13970/6985 15600/7800 14080/7040 16500/8250 18620/9310 21010/10505 23430/11715 20570/10285 22000/11000 23870/11935 27060/13530 29700/14850 34980/17490 38700/19350 37540/18770 44320/22160 49370/24685 55040 / 27520 53080/26540 61590/30795 66450/33225 71510/35755 75000/37500 89000/44500 97200/48600 103700/51850 67/50 65/48 67/49 70/52 72/53 73/58 69/51 70/52 71/53 72/54 73/55 75/57 76/58 78/60 79/61 80/62 81/63 82/64 84/66 86/68 87/69 91/73 89/71 90/72 91/73 92/74 92/74 93/75 93/75 94/76 R.R.P. € BOX HBF 400ºC/2h 2.070,90 2.150,60 2.148,00 2.360,90 2.464,90 2.728,40 2.336,10 2.464,50 2.728,40 2.983,30 3.431,00 2.653,60 2.946,30 3.203,10 3.584,10 3.230,70 3.612,40 3.994,40 4.078,50 4.459,80 4.758,60 5.366,30 4.877,10 5.484,70 8.375,20 9.722,10 10.436,50 11.573,70 12.139,50 18.816,10 41 SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE HMF-HMFX Long cased axial fan 400ºC/2h MANUFACTURING FEATURES • Long cased axial fan with reinforced body. • Modular motor-impeller assembly. Cast aluminium impeller with variable pitch angle. Epoxy powder finishing coat. • Housing with motor access door. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class H insulation certified 400ºC/2h. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. HMF APPLICATIONS Designed for inline installation, they are suitable for: • Smoke emergency exhaust with motor inside the hazardous area. • Maximum working temperature: 60ºC. UNDER REQUEST • B form, 100% reversible impeller. 5% additional cost. • 300ºC/2h motor. • ATEX models (HMFX). 10% additional cost. INSIDE HMFX ACCESSORIES RFS INT PE RP AC BA-400 SIL-C PO THREE PHASE RANGE Model HMF / HMFX HMF 40 T4 0,55kW HMF 40 T4 0,75kW HMF 45 T4 0,55kW HMF 45 T4 0,75kW HMF 45 T6 0,55kW HMF 50 T4 0,55kW HMF 50 T4 0,75kW HMF 50 T6 0,55kW HMF 56 T4 0,75kW HMF 56 T4 1,1kW HMF 56 T4 1,5kW HMF 56 T6 0,55kW HMF 63 T4 0,75kW HMF 63 T4 1,1kW HMF 63 T4 1,5kW HMF 63 T4 2,2kW HMF 63 T4 3kW HMF 63 T6 0,55kW HMF 63 T6 0,75kW HMF 71 T4 1,1kW HMF 71 T4 1,5kW HMF 71 T4 2,2kW HMF 71 T4 3kW HMF 71 T6 0,55kW HMF 71 T6 0,75kW HMF 71 T6 1,1kW HMF 80 T4 2,2kW HMF 80 T4 3kW HMF 80 T4 4kW HMF 80 T6 0,75kW HMF 80 T6 1,1kW HMF 80 T6 1,5kW HMF 80 T6 2,2kW HMF 90 T4 3kW HMF 90 T4 4kW HMF 90 T4 5,5kW HMF 90 T4 7,5kW 42 Max. Curr. (A) R.P.M. max. 230 400 690 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg HMF 1400 1415 1400 1415 920 1400 1415 920 1415 1430 1435 920 1415 1430 1435 1455 1455 920 920 1430 1435 1455 1455 920 920 920 1455 1455 1455 920 920 960 960 1455 1455 1455 1455 2,69 3,46 2,69 3,46 2,6 2,69 3,46 2,6 3,46 4,33 5,89 2,6 3,46 4,33 5,89 7,97 10,74 2,6 3,46 4,33 5,89 7,97 10,74 2,6 3,46 5,11 7,97 10,74 3,46 5,11 6,41 9,01 10,74 - 1,56 2 1,56 2 1,5 1,56 2 1,5 2 2,5 3,4 1,5 2 2,5 3,4 4,6 6,2 1,5 2 2,5 3,4 4,6 6,2 1,5 2 2,95 4,6 6,2 8,2 2 2,95 3,7 5,2 6,2 8,2 10,8 14,5 4,73 4,73 6,24 8,37 0,55 0,75 0,55 0,75 0,55 0,55 0,75 0,55 0,75 1,1 1,5 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 2,2 3 4 0,75 1,1 1,5 2,2 3 4 5,5 7,5 4500 4700 7300 7500 5200 9200 10065 6000 12650 13970 15600 10170 14080 16500 18620 21010 23430 12430 13860 20570 22000 23870 27060 15400 17480 19640 29700 34980 38700 23100 25840 28600 30620 37540 44320 49370 55040 63 64 67 68 56 69 70 60 74 75 76 63 72 73 74 75 76 64 65 78 79 80 81 66 67 68 83 84 85 70 73 74 75 87 88 90 94 68 69 70 71 70 72 73 72 75 78 79 74 76 77 78 80 84 80 84 87 100 103 106 98 102 105 112 130 135 139 115 120 124 138 160 180 186 R.R.P. € HMF 400ºC/2h 1.496,30 1.512,50 1.514,10 1.527,90 1.688,40 1.530,10 1.544,00 1.704,40 1.559,40 1.635,10 1.817,10 1.718,20 1.576,70 1.798,20 2.017,40 2.253,30 2.686,30 2.153,10 2.355,10 1.906,00 2.092,80 2.331,00 2.747,00 1.970,50 2.014,50 2.114,00 2.544,80 2.862,60 3.029,20 2.210,00 2.344,00 2.693,40 2.775,30 3.074,10 3.101,40 3.503,90 3.775,80 SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE Max. Curr. (A) Model HMF / HMFX R.P.M. max. 230 400 690 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg HMF HMF 90 T6 1,5kW HMF 100 T6 2,2kW HMF 100 T6 3kW HMF 100 T6 4kW HMF 125 T4 11kW HMF 125 T4 15kW HMF 125 T4 18,5kW HMF 125 T4 22kW HMF 125 T6 3kW HMF 125 T6 4kW HMF 125 T6 7,5kW HMF 125 T6 11kW HMF 125 T4 18,5kW HMF 125 T4 22kW HMF 125 T6 3kW HMF 125 T6 4kW HMF 125 T6 7,5kW 960 960 945 945 1455 1455 1465 1465 945 945 968 966 1465 1465 945 945 968 6,41 9,01 12,12 12,12 12,12 - 3,7 5,2 7 9,3 20,9 27,9 35 40,8 7 9,3 16 23 35 40,8 7 9,3 16 5,37 12,07 16,11 20,21 23,56 5,37 9,24 13,28 20,21 23,56 5,37 9,24 1,5 2,2 3 4 11 15 18,5 22 3 4 7,5 11 18,5 22 3 4 7,5 30580 37740 45690 51450 82600 89000 97300 103700 50000 55800 64800 73600 97300 103700 50000 55800 64800 78 82 83 84 91 91 92 92 77 78 80 82 92 92 77 78 80 191 158 162 167 433 445 480 495 361 379 384 379 480 495 361 379 384 R.R.P. € HMF 400ºC/2h 3.083,40 3.656,40 3.299,60 3.871,30 8.038,20 8.481,40 10.244,90 10.669,20 6.206,60 6.512,30 7.981,60 9.372,60 10.244,90 10.669,20 6.206,60 6.512,30 7.981,60 THREE PHASE RANGE 2 SPEEDS Model HMF / HMFX HMF 40 T4/T8 0,75-0,15kW HMF 45 T4/T8 0,75-0,15kW HMF 50 T4/T8 0,75-0,15kW HMF 56 T4/T8 0,75-0,15kW HMF 56 T4/T8 1,1-0,18kW HMF 56 T4/T8 1,5-0,25kW HMF 63 T4/T8 0,75-0,15kW HMF 63 T4/T8 1,1-0,18kW HMF 63 T4/T8 1,5-0,25kW HMF 63 T4/T8 2,2-0,37kW HMF 63 T4/T8 3-0,55kW HMF 71 T4/T8 1,1-0,18kW HMF 71 T4/T8 1,5-0,25kW HMF 71 T4/T8 2,2-0,37kW HMF 71 T4/T8 3-0,55kW HMF 80 T4/T8 2,2-0,37kW HMF 80 T4/T8 3-0,55kW HMF 80 T4/T8 4-0,75kW HMF 90 T4/T8 3-0,55kW HMF 90 T4/T8 4-0,75kW HMF 90 T4/T8 5,5-1,1kW HMF 90 T4/T8 7,5-1,5kW HMF 100 T4/T8 5,5-1,1kW HMF 100 T4/T8 7,5-1,5kW HMF 100 T4/T8 10-2kW HMF 125 T4/T8 10-2kW HMF 125 T4/T8 14-3kW HMF 125 T4/T8 16,5-3,3kW HMF 125 T4/T8 20-4kW R.P.M. max. Max. Curr. (A) 400V Rated Power kW Air flow m3/h Sound dB (A) Weight Kg HMF 1420/710 1420/710 1420/710 1420/710 1430/715 1430/715 1420/710 1430/715 1430/715 1430/715 1445/725 1430/715 1430/715 1430/715 1445/725 1430/715 1445/725 1450/730 1445/725 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 1450/730 2,2/0,85 2,2/0,85 2,2/0,85 2,2/0,85 2,85/0,85 3,75/1,15 2,2/0,85 2,85/0,85 3,75/1,15 5,1/1,6 6,5/2,55 2,85/0,85 3,75/1,15 5,1/1,6 6,5/2,55 5,1/1,6 6,5/2,55 8,8/3,3 6,5/2,55 8,8/3,3 11,1/3,5 15/4,7 11,1/3,5 15/4,7 16,5/5,2 16,5/5,2 29/7 35,4/7,9 42,3/8,2 0,75/0,15 0,75/0,15 0,75/0,15 0,75/0,15 1,1/0,18 1,5/0,25 0,75/0,15 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 2,2/0,37 3/0,55 4/0,75 3/0,55 4/0,75 5,5/1,1 7,5/1,5 5,5/1,1 7,5/1,5 10/2 10/2 14/3 16,5/3,3 20/4 4700/2350 7500/3750 8500/4250 12650/6325 13970/6985 15600/7800 14080/7040 16500/8250 18620/9310 21010/10505 23430/11715 20570/10285 22000/11000 23870/11935 27060/13530 29700/14850 34980/17490 38700/19350 37540/18770 44320/22160 49370/24685 55040 / 27520 53080/26540 61590/30795 66450/33225 82600/41300 89000/44500 97300/48650 103700/51850 67/50 68/51 70/52 73/55 75/57 76/58 72/54 73/55 74/56 75/57 76/58 78/60 79/61 81/63 82/64 83/65 84/66 85/67 87/69 89/71 90/72 94/76 92/74 93/75 94/76 92/74 93/75 93/75 94/76 69 71 73 75 78 79 76 77 78 80 84 87 100 103 106 112 130 135 138 160 180 186 163 169 172 433 445 480 495 R.R.P. € HMF 400ºC/2h 1.828,90 1.851,00 1.900,60 1.968,60 2.290,20 2.398,50 2.220,30 2.381,10 2.651,00 2.791,80 2.968,70 2.509,20 2.707,20 3.109,10 2.905,30 3.002,40 3.404,50 3.473,70 3.779,30 4.355,20 4.551,70 4.886,10 4.547,60 5.166,60 7.993,10 9.488,60 10.791,80 11.357,60 18.034,20 43 SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE JF Jet fan 400ºC/2h - 300ºC/2h MANUFACTURING FEATURES Jet fan models are composed of an axial fan and two silencers. FAN: • Axial fan with galvanised steel casing. Connection box accessible from the side by a removable door. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class H insulation, CERTIFIED 400ºc/2h or 300ºc/2h. Standard voltages 230/400V 50Hz for 1 speed motors and 400V 50Hz for 2 speed motors. SILENCERS: • Casing made of galvanised steel. Inner duct made of perforated galvanised steel sheet. Silencers filled with mineral wool of high acoustic absorption properties, preventing most of the fan noise to be propagated. • Unidirectional JF UN is equipped with a protection guard at the inlet side and a deflector at the outlet. • Reversible JF RE is equipped with deflectors on both sides. The deflector directs the air away from the ceiling and obstacles such as beams or ducting, sweeping the whole volume of air to the closest extraction point. APPLICATIONS • Conceived for car parkings and large spaces where polluted air or smoke from an accidental fire needs to be removed effectively. An optimized design minimizes the height needed for their installation and assures a silent operation. • Maximum working temperature: 60ºC. UNDER REQUEST • Epoxy painted casing in blue or grey. INSIDE ACCESSORIES RFS INT PE THREE PHASE RANGE Model Thrust (N) Discharge speed (m/s) JF 300 T2 UN JF 300 T2 RE JF 400 T2 UN JF 400 T2 RE 30,7 20,1 53,6 47,9 22 18 20 19 R.P.M. max. 2875 2875 2875 2875 Max. Curr. (A) Rated Power kW 230 400 2,86 2,86 3,98 3,98 1,65 1,65 2,3 2,3 0,75 0,75 1,1 1,1 Air flow m3/h Sound dB (A) Weight Kg 5750 4600 9600 8900 47 46 53 51 60 60 70 70 R.R.P. € 400ºC/2h 2.340,00 2.457,00 3.016,00 3.166,80 R.R.P. € 300ºC/2h 2.106,00 2.211,30 2.714,40 2.850,10 THREE PHASE RANGE 2 SPEEDS Model Thrust (N) JF 300 T2/T4 UN JF 300 T2/T4 RE JF 400 T2/T4 UN JF 400 T2/T4 RE 30,7/7,7 20,1/5 53,6/13,4 47,9/12 44 Discharge speed (m/s) 22/11 18/9 20/10 19/9,5 R.P.M. máx. 2860/1460 2850/1460 2860/1460 2850/1460 Max. C. (A) Rated Power kW 230 1,7/0,4 1,7/0,4 2,4/0,5 2,4/0,5 0,75/0,12 0,75/0,12 1,1/0,18 1,1/0,18 Air flow m3/h Sound dB (A) Weight Kg 5750/2875 4600/2300 9600/4800 8900/4450 47/22 46/22 53/26 51/25 60 60 70 70 R.R.P. € 400ºC/2h 2.600,00 2.730,00 3.359,20 3.527,20 R.R.P. € 300ºC/2h 2.340,00 2.457,00 3.023,30 3.174,40 SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE BOX RLF BOX RLFX Backward centrifugal impeller in soundproof cabinet 400ºC/2h MANUFACTURING FEATURES • Box manufactured in galvanised steel sheet. • Circular inlet and outlet. • Backward impeller, direct coupling motor. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class H insulation certified 400ºC/2h. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Interchangeable panels. UNDER REQUEST • Vertical discharge. • 300ºC/2h motor. • ATEX models (BOX RLFX). BOX RLF APPLICATIONS Designed for inline installation, they are suitable for: • Smoke emergency exhaust with motor inside the hazardous area and high pressures needed. • Maximum working temperature: 60ºC. INSIDE BOX RLFX ACCESSORIES RFS INT PE BA-400 SIL-C SIL-R THREE PHASE RANGE Max. Curr. (A) Code Model BOX RLF / BOX RLFX R.P.M. max. 230 400 241410186 241430186 241450186 241500186 241510186 241560186 241580186 241570186 241590186 241630186 241640186 241710186 241740186 241720186 241750186 241800186 241810186 BOX RLF 400 T4/L 0,75kW BOX RLF 400 T4/H 0,75kW BOX RLF 450 T4 1,1kW BOX RLF 500 T4 1,5kW BOX RLF 500 T6 0,75kW BOX RLF 560 T4/L 3kW BOX RLF 560 T4/H 3kW BOX RLF 560 T6/L 1,5kW BOX RLF 560 T6/H 1,5kW BOX RLF 630 T4 5,5kW BOX RLF 630 T6 1,5kW BOX RLF 710 T4/L 7,5kW BOX RLF 710 T4/H 7,5kW BOX RLF 710 T6/L 3kW BOX RLF 710 T6/H 3kW BOX RLF 800 T4 15kW BOX RLF 800 T6 4kW 1400 1400 1400 1420 910 1410 1410 930 930 1450 930 1420 1420 955 955 1430 955 3,74 3,74 4,87 6,32 4,1 11,53 11,53 7,2 7,2 7,2 12,1 12,1 - 2,16 2,16 2,81 3,65 2,4 6,66 6,66 4,2 4,2 13,14 4,2 16,5 16,5 7 7 30,59 9,35 690 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 7,30 9,50 9,50 17,68 5,37 0,75 0,75 1,1 1,5 0,75 3 3 1,5 1,5 5,5 1,5 7,5 7,5 3 3 15 4 4500 4500 5971 9000 6180 11600 12378 7750 8250 17000 11673 21500 23000 15050 16500 27900 19500 52 61 62 64 54 66 68 56 57 69 59 71 72 63 65 75 66 90 95 120 135 135 185 190 175 180 210 200 225 230 215 220 280 270 R.R.P. € BOX RLF 400º C/2h 2.225,90 2.431,30 2.523,70 2.487,40 2.650,10 2.719,40 2.799,80 2.656,30 2.754,30 4.332,80 3.053,00 4.681,30 4.800,90 3.743,00 3.856,00 6.772,80 4.727,80 THREE PHASE RANGE 2 SPEEDS Model BOX RLF / BOX RLFX R.P.M. max. BOX RLF 400/H T4/T8 0,75-0,15kW BOX RLF 450 T4/T8 1,1-0,18kW BOX RLF 500 T4/T8 1,5-0,25kW BOX RLF 560/H T4/T8 3-0,55kW BOX RLF 630 T4/T8 5,5-1,1kW BOX RLF 710/H T4/T8 7,5-1,5kW BOX RLF 800 T4/T8 14-3kW 1380/685 1370/695 1375/700 1400/700 1455/720 1455/720 1470/730 Max. Curr. (A) 400V 3000 1500 - 1,76 2,4 3,3 5,3 10,3 13,3 28,6 750 Rated Power kW Air flow m3/h Sound dB (A) 0,77 1,25 1,80 2,80 3,30 4,40 9,3 0,75/0,15 1,1/0,18 1,5/0,25 3/0,55 5,5/1,1 7,5/1,5 14/3 3950/2000 5971/2980 8250/4125 12275/6150 16300/8150 23623/11810 27900/13950 61/49 64/51 66/53 68/54 71/57 73/59 77/62 R.R.P. € BOX RLF 400º C/2h 2.796,00 2.902,30 2.860,50 3.219,70 4.982,70 5.521,10 7.788,80 45 SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE MBRF Backward centrifugal 400ºC/2h MANUFACTURING FEATURES • Reinforced rolling steel sheet housings completely welded (internally and externally). Epoxy powder finishing coat. • Reinforced high efficiency backward curved impeller. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class H insulation certified 400ºC/2h. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. APPLICATIONS Designed for inline installation, they are suitable for: • Smoke emergency exhaust with motor inside the hazardous area and high pressures needed. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • Drain plug and inspection door. • 300ºC/2h motor. • 2 speed motors. INSIDE ACCESSORIES RFS INT PE AC EI BA-400 SIL-C SIL-R THREE PHASE RANGE Code 243400108 243450108 243510108 243500108 243570108 243560108 243650108 243640108 243730108 243720108 46 Model MBRF 40/12 T4 0,75kW MBRF 45/14 T4 1,1kW MBRF 50/16 T4 1,5kW MBRF 50/16 T6 0,75kW MBRF 56/18 T4 3kW MBRF 56/18 T6 1,5kW MBRF 63/20 T4 5,5kW MBRF 63/20 T6 1,5kW MBRF 71/22 T4 7,5kW MBRF 71/22 T6 3kW R.P.M. max. 1415 1430 1435 920 1455 960 1455 960 1455 945 Max. Curr. (A) 230 400 690 3,46 4,33 5,89 3,46 10,74 6,41 6,41 12,12 2 2,5 3,4 2 6,2 3,7 10,8 3,7 14,5 7 6,24 8,37 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,75 1,1 1,5 0,75 3 1,5 5,5 1,5 7,5 3 5640 7200 9500 7100 13500 9500 19000 12000 25500 17000 73 76 81 71 83 73 84 76 87 77 98 109 125 122 145 135 258 220 345 335 R.R.P. € 2.189,20 2.612,70 3.358,50 3.252,80 4.303,50 4.087,50 5.095,30 4.507,60 5.416,50 6.307,50 SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE SF Axial roof fan with adjustable inclination base 400ºC/2h - 300ºC/2h MANUFACTURING FEATURES • Fully manufactured in galvanised steel sheet. • Variable pitch angle aluminium impeller. • Bird protection guard included. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class H insulation certified 400ºC/2h. • Manufactured with standard voltages: 230/400V 50Hz in three phase motors. APPLICATIONS Specially designed for roof installation, they are suitable for: • Smoke emergency exhaust. • Air renewal in buildings and industries. • Maximum working temperature: 60ºC. UNDER REQUEST • B form impeller (air flow from impeller to motor), 100% reversible impeller. • Aluminium impeller. • 60Hz fans and special voltages. • Flameproof and explosion-proof fans with ATEX certified motors and 3 meter RVFV 4x2,5mm core cable. • Custom pitch according to roof slope: Type A: from 0% to 16% Type B: from 16% to 38% • Motorised damper with registered motor in IP-65 box to avoid heat loss in winter. • ‘Double channel’ function to exhaust air in dropped ceilings or closed environments and save energy. • Lacquered or stainless steel finishing coats. • 300ºC/2h motor. INSIDE ACCESSORIES RFS INT PE THREE PHASE RANGE Model R.P.M. max. SF 450 T6 0,55kW SF 560 T4 0,75kW SF 560 T4 1,1kW SF 560 T4 1,5kW SF 560 T6 0,55kW SF 630 T4 0,75kW SF 630 T4 1,1kW SF 630 T4 1,5kW SF 630 T4 2,2kW SF 630 T4 3kW SF 630 T6 0,55kW SF 630 T6 0,75kW SF 710 T4 1,1kW SF 710 T4 1,5kW SF 710 T4 2,2kW SF 710 T4 3kW SF 710 T6 0,55kW SF 710 T6 0,75kW SF 710 T6 1,1kW SF 800 T4 2,2kW SF 800 T4 3kW SF 800 T4 4kW SF 800 T6 0,75kW SF 800 T6 1,1kW SF 800 T6 1,5kW SF 800 T6 2,2kW 920 1415 1430 1435 920 1415 1430 1435 1455 1455 920 920 1430 1435 1455 1455 920 920 920 1455 1455 1455 920 920 960 960 Max. Curr. (A) 230 400 690 2,60 3,46 4,33 5,89 2,60 3,46 4,33 5,89 7,97 10,74 2,60 3,46 4,33 5,89 7,97 10,74 2,60 3,46 5,11 7,97 10,74 3,46 5,11 6,41 9,01 1,5 2 2,5 3,4 1,5 2 2,5 3,4 4,6 6,2 1,5 2 2,5 3,4 4,6 6,2 1,5 2 2,95 4,6 6,2 8,2 2 2,95 3,7 5,2 4,73 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,55 0,75 1,1 1,5 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 2,2 3 4 0,75 1,1 1,5 2,2 4680 10120 11180 12480 8140 11260 13200 14900 16810 18740 9940 11090 16460 17600 19100 21650 12320 13980 15710 23760 27980 30960 18480 20670 22880 24500 68 75 78 79 74 76 77 78 80 84 80 84 87 100 103 106 98 102 105 112 130 135 139 115 120 124 56 73 75 76 63 72 73 74 75 76 63 65 78 79 81 82 65 67 68 83 84 85 70 73 74 75 R.R.P. € 400º C/2h 3.286,70 3.193,90 3.300,60 3.682,30 3.449,20 3.180,50 3.538,10 3.928,10 4.249,40 4.920,20 3.504,60 3.777,70 3.747,40 4.085,10 4.426,40 5.024,70 3.776,00 4.064,40 4.098,10 4.725,70 5.181,10 5.421,30 4.389,70 4.663,80 4.948,00 5.194,60 R.R.P. € 300º C/2h 2.958,00 2.874,50 2.970,60 3.314,10 3.104,20 2.862,50 3.184,30 3.535,30 3.824,50 4.428,20 3.154,10 3.399,90 3.372,70 3.676,60 3.983,80 4.522,20 3.398,40 3.658,00 3.688,30 4.253,10 4.663,00 4.879,20 3.950,80 4.197,40 4.453,20 4.675,10 47 SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE THREE PHASE RANGE 2 SPEEDS Model R.P.M. max. SF 560 T4/T8 0,75-0,15kW SF 560 T4/T8 1,1-0,18kW SF 560 T4/T8 1,5-0,25kW SF 630 T4/T8 0,75-0,15kW SF 630 T4/T8 1,1-0,18kW SF 630 T4/T8 1,5-0,25kW SF 630 T4/T8 2,2-0,37kW SF 630 T4/T8 3-0,55kW SF 710 T4/T8 1,1-0,18kW SF 710 T4/T8 1,5-0,25kW SF 710 T4/T8 2,2-0,37kW SF 710 T4/T8 3-0,55kW SF 800 T4/T8 2,2-0,37kW SF 800 T4/T8 3-0,55kW SF 800 T4/T8 4-0,75kW 1420/710 1430/715 1430/715 1420/710 1430/715 1430/715 1430/715 1445/725 1430/715 1430/715 1430/715 1445/725 1430/715 1445/725 1450/730 48 Max. C.(A) 400V Rated Power kW 1500 750 2,2 2,85 3,75 2,2 2,85 3,75 5,1 6,5 2,85 3,75 5,1 6,5 5,1 6,5 8,8 0,85 0,85 1,15 0,85 0,85 1,15 1,6 2,55 0,85 1,15 1,6 2,55 1,6 2,55 3,3 0,75/0,15 1,1/0,18 1,5/0,25 0,75/0,15 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 2,2/0,37 3/0,55 4/0,75 Air flow m3/h Sound dB (A) Weight Kg 10120/5060 11180/5590 12480/6240 11260/5630 13200/6600 14900/7450 16810/8400 18740/9370 16460/8230 17600/8800 19100/9550 21650/10820 23760/11880 27980/13990 30960/15480 77 80 81 78 79 80 82 86 89 102 105 108 114 132 137 73/55 75/57 76/58 72/54 73/55 74/56 75/57 76/58 78/60 79/61 81/63 82/64 83/65 84/66 85/67 R.R.P. € 400º C/2h 3.542,40 3.633,70 4.064,70 3.668,40 3.970,90 4.186,30 4.547,90 5.085,40 3.972,40 4.439,20 4.705,20 5.242,60 4.970,10 5.641,70 6.044,90 R.R.P. € 300º C/2h 3.188,20 3.270,30 3.658,30 3.301,60 3.573,80 3.767,70 4.093,10 4.576,90 3.575,10 3.995,30 4.234,70 4.718,40 4.473,10 5.077,50 5.440,40 SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA Official homologation by the European laboratory CSTB according to NF EN12101-3: 2002 CTH Centrifugal roof 400ºC/2h MANUFACTURING FEATURES • Roof cowl made of polyethylene UV resistant. • Structure, roof base support and bird protection guard made of galvanised steel. • High efficiency backward curved impellers of galvanised steel. • Vertical discharge with KITV accessory. • Standard asynchronous motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors, 230/400V 50Hz in three phase motors and 400V 50Hz in 2 SPEED MOTORS. CTH (horizontal) • Air renewal in buildings and industries. • Industrial and professional kitchen hoods. • Maximum continuous operation temperature: 80ºC. UNDER REQUEST • Security switch mounted and wired. APPLICATIONS Specially designed for roof installation, they are suitable for: • Smoke extraction. • Smoke emergency exhaust with motor outside the hazardous area (400ºC/2h certificate). CTH + KITV (vertical) ACCESSORIES OUTSIDE REG RFS INT PE SINGLE PHASE RANGE Code Model R.P.M. max. Max. Curr. (A) 230 Rated Power kW Air flow m3/h Weight Kg CTH Weight Kg CTH+KITV 300815900 300816000 300816100 300816200 300816300 300816400 300816500 300816600 300816700 CTH 28 M4 0,22kW CTH 32 M4 0,22kW CTH 36 M4 0,22kW CTH 40 M4 0,37kW CTH 45 M4 0,75kW CTH 45 M6 0,25kW CTH 50 M4 1,1kW CTH 50 M6 0,37kW CTH 56 M6 0,75kW 1450 1450 1450 1450 1450 950 1450 950 950 2,2 2,2 2,2 3,1 5,4 2,3 7 3 6,5 0,22 0,22 0,22 0,37 0,75 0,25 1,1 0,37 0,75 1300 1850 2700 3750 5500 3670 7500 5000 6940 22 22 24 32 38 33 43 37 62 26 26 28 40 46 41 51 45 75 R.P.M. max. Max. C. (A) 230 400 Rated Power kW Air flow m3/h Weight Kg CTH Weight Kg CTH+KITV 0,25 0,25 0,25 0,25 0,25 0,37 0,25 0,75 0,37 1,1 0,37 2,2 0,75 0,37 1,5 0,75 2,2 1,1 4 2,2 1300 1850 1240 2700 1800 3750 2500 5500 3670 7500 5000 10400 6940 5200 9900 7430 15000 11250 20000 15000 22 22 20 23 21 31 29 35 34 41 37 67 60 60 74 73 111 105 136 131 26 26 24 27 25 39 37 43 42 49 45 80 73 73 87 86 132 126 157 152 R.R.P. € CTH 645,50 653,10 717,70 903,70 1.013,90 1.040,40 1.222,70 1.211,30 1.587,20 R.R.P. € CTH+KITV 667,00 674,00 736,00 953,00 1.059,00 1.084,00 1.258,00 1.247,00 1.656,00 THREE PHASE RANGE Code 300816800 300816900 300817000 300817100 300817200 300817300 300817400 300817500 300817600 300817700 300817800 300817900 300818000 300818100 300818200 300818300 300818400 300818500 300818600 300818700 Model CTH 28 T4 0,25kW CTH 32 T4 0,25kW CTH 32 T6 0,25kW CTH 36 T4 0,25kW CTH 36 T6 0,25kW CTH 40 T4 0,37kW CTH 40 T6 0,25kW CTH 45 T4 0,75kW CTH 45 T6 0,37kW CTH 50 T4 1,1kW CTH 50 T6 0,37kW CTH 56 T4 2,2kW CTH 56 T6 0,75kW CTH 56 T8 0,37kW CTH 63 T6 1,5kW CTH 63 T8 0,75kW CTH 71 T6 2,2kW CTH 71 T8 1,1kW CTH 80 T6 4kW CTH 80 T8 2,2kW 1450 1450 950 1450 950 1450 950 1450 950 1450 950 1450 950 725 950 725 950 725 950 725 0,48 0,48 0,5 0,48 0,5 0,64 0,71 1,13 0,71 1,52 0,71 2,77 1,27 0,78 2,19 1,39 3,12 1,85 5,31 3,44 0,84 0,84 0,87 0,84 0,84 1,1 1,23 1,95 1,23 2,6 1,23 4,8 2,2 1,35 3,8 2,4 5,4 3,2 9,2 5,96 R.R.P. CTH 609,90 630,10 630,10 630,10 630,10 775,50 775,50 872,40 832,00 1.046,10 981,40 1.397,40 1.268,20 1.336,90 1.619,60 1.462,10 1.898,30 1.861,90 2.152,70 2.306,20 R.R.P. CTH+KITV 598,00 616,00 616,00 616,00 616,00 786,00 786,00 874,00 837,00 1.030,00 972,00 1.394,00 1.278,00 1.340,00 1.594,00 1.453,00 1.934,00 1.901,00 2.162,00 2.300,00 49 SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE THREE PHASE RANGE 2 SPEEDS Code Model R.P.M. max. Max. Curr. (A) 400V Rated Power kW Air flow m3/h Weight Kg CTH Weight Kg CTH+KITV 300818800 300818900 300819000 300819100 300819200 300819400 300819300 300819500 300819600 300819800 300819700 300819900 300820000 300820100 300820200 300820300 300820400 300820500 300820600 CTH 32 T4/T8 0,37-0,08kW CTH 36 T4/T8 0,37-0,08kW CTH 40 T4/T8 0,37-0,08kW CTH 45 T4/T8 0,8-0,2kW CTH 45 T6/T8 0,25-0,12kW CTH 50 T4/T6 1,1-0,3kW CTH 50 T4/T8 1,2-0,3kW CTH 50 T6/T8 0,37-0,2kW CTH 50 T6/T12 0,37-0,07kW CTH 56 T4/T6 2,2-0,7kW CTH 56 T4/T8 2,2-0,55kW CTH 56 T6/T8 0,75-0,37kW CTH 56 T6/T12 0,75-0,2kW CTH 63 T6/T8 1,5-0,75kW CTH 63 T6/T12 1,5-0,75kW CTH 71 T6/T8 2,2-1,3kW CTH 71 T6/T12 2,2-0,55kW CTH 80 T6/T8 4- 1,1kW CTH 80 T6/T12 4-1,0kW 1450/725 1450/725 1450/725 1450/725 950/725 1450/950 1450/725 950/725 950/450 1450/950 1450/725 950/725 950/450 950/725 950/450 950/725 950/450 950/725 950/450 1,8/0,5 1,8/0,5 1,8/0,5 2/0,9 1/0,94 3/1,5 2,9/1,3 1,5/1,1 1,59/0,7 5,2/2,5 5/2 2,7/1,7 2,4/1 4/3 4,3/1,7 6,5/5 6,4/2,6 11,3/4,9 12,6/5,2 0,37/0,08 0,37/0,08 0,37/0,08 0,8/0,2 0,25/0,12 1,1/0,3 1,2/0,3 0,37/0,2 0,37/0,07 2,2/0,7 2,2/0,55 0,75/0,37 0,75/0,15 1,5/0,75 1,5/0,75 2,2/1,3 2,2/0,55 4/1,1 4/1,0 1850/930 2700/1350 3750/1880 5500/2750 3670/2750 7500/5000 7500/3750 5000/3750 5000/2500 10400/6940 10400/5200 6940/5200 6940/3470 9900/7430 9900/4950 15000/11250 15000/7500 20000/15000 20000/10000 22 23 31 36 33 44 44 37 41 71 80 62 63 93 75 127 116 145 131 26 27 39 44 41 52 52 45 49 84 93 75 73 106 88 148 137 166 152 MBC/FA R.R.P. CTH R.R.P. CTH+KITV 735,10 735,10 880,50 997,60 1.074,30 1.288,40 1.171,30 1.252,00 1.134,90 1.676,10 1.510,50 1.619,60 1.579,20 1.813,40 2.092,10 2.209,20 2.512,20 2.770,60 2.867,60 709,6 709,6 880,3 985,6 1.054,50 1.246,90 1.141,70 1.109,00 1.214,30 1.644,40 1.495,60 1.557,30 1.593,60 1.318,30 1.767,80 2.484,80 2.212,60 2.804,30 2.490,80 Centrifugal cubic fan 400ºC/2h MANUFACTURING FEATURES • Reinforced rolling steel sheet housings completely welded (internally and externally) with epoxy powder finishing coat. • Forward curved reinforced impeller. • Standard asynchronous squirrel-cage motor with IP55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. peratures. • Clean air transport. • Maximum working temperature: carried air up to 250ºC; environment: single phase 50ºC, three phase 60ºC. UNDER REQUEST • 2 speed motors. APPLICATIONS Designed for inline installation, they are suitable for: • Smoke emergency exhaust with motor outside the hazardous area. • Hot air exhaust in ovens or facilities with high temOUTSIDE ACCESSORIES RFS INT PE AC EI BA-400 SIL-C SIL-R SINGLE PHASE RANGE Code Model R.P.M. max. 253310173 253300173 253380173 MBC/FA 25/10 M4 1,1kW MBC/FA 25/10 M6 0,55kW MBC/FA 28/11 M6 0,75kW 1400 900 900 Max. Curr. (A) 230 400 7,45 3,84 4,97 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,1 0,55 0,75 3500 1900 3600 70 62 60 63 61 67 - R.R.P. € 830,30 810,60 870,80 THREE PHASE RANGE 50 Code Model R.P.M. max. 253310186 253300186 253360186 253370186 253380186 MBC/FA 25/10 T4 1,1kW MBC/FA 25/10 T6 0,55kW MBC/FA 28/11 T2 4kW MBC/FA 28/11 T4 2,2kW MBC/FA 28/11 T6 0,75kW 1400 900 2890 1430 910 Max. Curr. (A) 230 400 690 4,74 2,85 14,2 8,06 4 2,75 1,65 8,2 5 2,3 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,1 0,55 4 2,2 0,75 3500 1900 4000 5000 3600 70 62 81 82 60 64 63 66 75 69 R.R.P. € 786,00 739,40 1.020,70 942,40 833,80 SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE THREE PHASEModel RANGE Code 253460186 253450186 253430186 253480186 253490186 253470186 253510186 253520186 253500186 253530186 253540186 253560186 MBC/FA 31/12 T4 3kW MBC/FA 31/12 T4 4kW MBC/FA 31/12 T6 1,5kW MBC/FA 35/14 T4 3kW MBC/FA 35/14 T4 5,5kW MBC/FA 35/14 T6 1,5kW MBC/FA 40/16 T4 5,5kW MBC/FA 40/16 T4 7,5kW MBC/FA 40/16 T6 2,2kW MBC/FA 45/18 T4 5,5kW MBC/FA 45/18 T4 7,5kW MBC/FA 45/18 T6 2,2kW MBRC/FA Max. Curr. (A) 230 400 690 R.P.M. max. 1430 1440 940 1430 1440 940 1440 1440 940 1440 1440 940 11,7 15,2 6,9 11,7 6,9 9,7 9,7 6,8 8,8 4 6,8 12 4 12 15 5,6 12 15 5,6 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 3 4 1,5 3 5,5 1,5 5,5 7,5 2,2 5,5 7,5 2,2 5700 6800 4500 6000 8700 5500 9000 10500 7000 8000 11000 9000 72 73 66 78 79 70 78 79 71 80 82 76 72 73 71 75 79 73 87 89 86 91 93 90 6,9 6,9 8,6 6,9 8,6 - R.R.P. € 1.298,80 1.341,30 1.131,70 1.245,90 1.459,60 1.190,20 1.643,60 1.851,70 1.404,20 1.799,10 2.007,30 1.538,70 Backward centrifugal 400ºC/2h MANUFACTURING FEATURES • Reinforced rolling steel sheet housings completely welded (internally and externally) with epoxy powder finishing coat. • Reinforced high efficiency backward curved impeller. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Clean and slightly dusty air transport. • Maximum working temperature: carried air up to 250ºC; environment: single phase 50ºC, three phase 60ºC. UNDER REQUEST • 2 speed motors. APPLICATIONS Designed for inline installation, they are suitable for: • Smoke emergency exhaust with motor outside the hazardous area. • Hot air exhaust in ovens or facilities with high temperatures. ACCESSORIES RFS INT PE AC EI OUTSIDE BA-400 SIL-C SIL-R SINGLE PHASE RANGE Code 243400173 243450173 243510173 243500173 Model MBRC/FA 40/12 M4 0,75kW MBRC/FA 45/14 M4 1,1kW MBRC/FA 50/16 M4 1,5kW MBRC/FA 50/16 M6 0,75kW R.P.M. max. Max. Curr. (A) 230 400 1400 1400 1400 900 5,45 7,45 9,83 4,97 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,75 1,1 1,5 0,75 5640 7000 9500 7100 72 73 76 70 71 90 74 69 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 3 0,75 1,1 1,5 0,75 3 1,5 5,5 1,5 7,5 3 8500 5640 7000 9500 7100 13500 9500 19000 12000 25500 17000 85 72 73 76 70 80 70 83 72 85 77 82 71 90 74 69 97 89 155 113 256 205 R.R.P. € 1.610,30 1.815,30 2.006,70 2.005,60 THREE PHASE RANGE Code Model R.P.M. max. 243410186 243400186 243450186 243510186 243500186 243570186 243560186 243650186 243640186 243730186 243720186 MBRC/FA 40/12 T2 3kW MBRC/FA 40/12 T4 0,75kW MBRC/FA 45/14 T4 1,1kW MBRC/FA 50/16 T4 1,5kW MBRC/FA 50/16 T6 0,75kW MBRC/FA 56/18 T4 3kW MBRC/FA 56/18 T6 1,5kW MBRC/FA 63/20 T4 5,5kW MBRC/FA 63/20 T6 1,5kW MBRC/FA 71/22 T4 7,5kW MBRC/FA 71/22 T6 3kW 2870 1400 1400 1400 910 1430 940 1440 940 1440 960 Max. Curr. (A) 230 400 690 11,1 3,48 4,74 6,31 4 11,7 6,9 6,9 12,4 6,4 2,01 2,75 3,65 2,3 6,8 4 12 4 15 7,2 6,9 8,6 - R.R.P. € 1.765,80 1.590,30 1.802,50 2.052,30 1.968,60 2.422,50 2.237,10 3.080,60 2.728,80 3.562,10 3.213,70 51 SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE BVFC Belt driven centrifugal cabinet fan 400ºC/2h MANUFACTURING FEATURES • Fans in compact thermal and soundproof cabinets with motor and transmission set outside the airstream. • Double inlet forward curved impeller. • Transmission bearings specially designed for high temperatures. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Industrial and professional kitchen hoods. • Maximum working temperature: carried air 100ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • Box for outdoor applications. • Auxiliary motor base. • Vertical discharge. 5% additional cost. • Transmission ratio variation. APPLICATIONS Designed for inline installation, indoor or outdoor assembly, they are suitable for: • Smoke emergency exhaust with motor outside the hazardous area. OUTSIDE ACCESSORIES RFS INT PE PI VIS TCA TIAC THREE PHASE RANGE Model BVFC 9/9 0,37kW BVFC 9/9 0,55kW BVFC 9/9 0,75kW BVFC 9/9 1,1kW BVFC 10/10 0,37kW BVFC 10/10 0,55kW BVFC 10/10 0,75kW BVFC 10/10 1,1kW BVFC 10/10 1,5kW BVFC 12/12 0,37kW BVFC 12/12 0,55kW BVFC 12/12 0,75kW BVFC 12/12 1,1kW BVFC 12/12 1,5kW BVFC 12/12 2,2kW BVFC 15/15 0,55kW BVFC 15/15 0,75kW BVFC 15/15 1,1kW BVFC 15/15 1,5kW BVFC 15/15 2,2kW BVFC 15/15 3kW BVFC 15/15 4kW BVFC 18/18 1,1kW BVFC 18/18 1,5kW BVFC 18/18 2,2kW BVFC 18/18 3kW BVFC 18/18 4kW BVFC 18/18 5,5kW BVFC 20/20 1,5kW BVFC 20/20 2,2kW BVFC 20/20 3kW BVFC 20/20 4kW BVFC 20/20 5,5kW BVFC 20/20 7,5kW BVFC 22/22 1,5kW BVFC 22/22 2,2kW BVFC 22/22 3kW BVFC 22/22 4kW BVFC 22/22 5,5kW BVFC 22/22 7,5kW BVFC 22/22 11kW 52 230 1,94 2,69 3,48 4,74 1,94 2,69 3,48 4,74 6,31 1,94 2,69 3,48 4,74 6,31 8,06 2,69 3,48 4,74 6,31 8,06 11,7 15,2 4,74 6,31 8,06 11,7 15,2 6,31 8,06 11,7 15,2 6,31 8,06 11,7 15,2 - Max. Curr. (A) 400 690 1,12 1,56 2,01 2,75 1,12 1,56 2,01 2,75 3,65 1,12 1,56 2,01 2,75 3,65 5 1,56 2,01 2,75 3,65 5 6,8 8,8 2,75 3,65 5 6,8 8,8 12 3,65 5 6,8 8,8 12 15 3,65 5 6,8 8,8 12 15 20,9 6,9 6,9 8,6 6,9 8,6 12,02 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,37 0,55 0,75 1,1 0,37 0,55 0,75 1,1 1,5 0,37 0,55 0,75 1,1 1,5 2,2 0,55 0,75 1,1 1,5 2,2 3 4 1,1 1,5 2,2 3 4 5,5 1,5 2,2 3 4 5,5 7,5 1,5 2,2 3 4 5,5 7,5 1,5 2960 3230 3475 4215 3139 3588 4036 4485 5382 4275 4875 5250 6075 6700 7776 5915 6400 7760 8500 9450 10600 10924 11100 12100 13000 15800 16700 17764 13000 16000 18000 20000 21900 24500 15500 17625 20625 23125 25800 28000 32500 70 73 77 80 68 70 73 77 80 64 67 70 73 76 79 62 64 67 70 74 77 80 67 72 74 77 79 84 74 76 77 80 82 84 73 76 79 82 85 87 90 40 42 43 46 47 49 50 54 59 69 71 72 75 79 87 90 91 94 95 103 105 110 127 131 139 141 146 160 252 255 256 261 275 280 280 285 287 291 297 304 316 R.R.P. € 1.124,60 1.145,30 1.172,60 1.214,30 1.178,00 1.201,90 1.226,50 1.298,60 1.335,00 1.338,10 1.362,00 1.386,20 1.437,10 1.470,50 1.551,90 1.678,90 1.741,70 1.766,80 1.818,70 1.912,30 1.927,50 2.079,30 2.138,80 2.165,00 2.289,00 2.323,70 2.443,40 2.629,60 3.443,30 3.598,90 3.657,80 3.816,60 4.105,80 4.398,60 3.811,30 3.855,40 3.936,50 4.095,20 4.366,80 4.723,10 5.329,80 SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE Model 230 BVFC 25/25 2,2kW BVFC 25/25 3kW BVFC 25/25 4kW BVFC 25/25 5,5kW BVFC 25/25 7,5kW BVFC 25/25 11kW BVFC 30/28 2,2kW BVFC 30/28 3kW BVFC 30/28 4kW BVFC 30/28 5,5kW BVFC 30/28 7,5kW BVFC 30/28 11kW BVFC 30/28 15kW 8,06 11,7 15,2 8,06 11,7 15,2 - Max. Curr. (A) 400 690 5 6,8 8,8 12 15 20,9 5 6,8 8,8 12 15 20,9 27,9 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 2,2 3 4 5,5 7,5 1,5 2,2 3 4 5,5 7,5 11 15 20000 24900 27400 30000 33000 38000 22500 27500 34000 39000 43000 48500 54900 72 75 77 81 85 88 73 76 77 81 83 86 88 329 331 336 353 357 380 410 418 426 438 444 458 462 6,9 8,6 12,02 6,9 8,6 12,02 16,04 R.R.P. € 4.567,90 4.666,70 4.772,50 4.931,20 5.269,80 5.866,00 5.001,80 5.111,10 5.252,20 5.470,90 5.855,40 6.433,90 6.984,10 THREE PHASE RANGE 2 SPEEDS Model BVFC 9/9 T4/T8 0,60-0,12kW BVFC 9/9 T4/T8 0,85-0,20kW BVFC 9/9 T4/T8 1,40-0,30kW BVFC 10/10 T4/T8 0,60-0,12kW BVFC 10/10 T4/T8 0,85-0,20kW BVFC 10/10 T4/T8 1,40-0,30kW BVFC 10/10 T4/T8 1,80-0,40kW BVFC 12/12 T4/T8 0,60-0,12kW BVFC 12/12 T4/T8 0,85-0,20kW BVFC 12/12 T4/T8 1,40-0,30kW BVFC 12/12 T4/T8 1,80-0,40kW BVFC 12/12 T4/T8 2,2-0,60kW BVFC 15/15 T4/T8 0,60-0,12kW BVFC 15/15 T4/T8 0,85-0,20kW BVFC 15/15 T4/T8 1,40-0,30kW BVFC 15/15 T4/T8 1,80-0,40kW BVFC 15/15 T4/T8 2,20-0,60kW BVFC 15/15 T4/T8 2,80-0,70kW BVFC 15/15 T4/T8 4-1kW BVFC 18/18 T4/T8 1,40-0,30kW BVFC 18/18 T4/T8 1,80-0,40kW BVFC 18/18 T4/T8 2,20-0,60kW BVFC 18/18 T4/T8 2,80-0,70kW BVFC 18/18 T4/T8 4-1kW BVFC 18/18 T4/T8 6,50-1,80kW Max. Curr. (A) 400V Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,72/0,75 2,33/0,88 3,63/1,21 1,72/0,75 2,33/0,88 3,63/1,21 4,44/1,43 1,72/0,75 2,33/0,88 3,63/1,21 4,44/1,43 5,34/2,18 1,72/0,75 2,33/0,88 3,63/1,21 4,44/1,43 5,34/2,18 6,3/2,42 9,2/3,7 3,63/1,21 4,44/1,43 5,34/2,18 6,3/2,42 9,2/3,7 13,9/5,62 0,6/0,12 0,85/0,2 1,4/0,3 0,6/0,12 0,85/0,2 1,4/0,3 1,8/0,4 0,6/0,12 0,85/0,2 1,4/0,3 1,8/0,4 2,2/0,6 0,6/0,12 0,85/0,2 1,4/0,3 1,8/0,4 2,2/0,6 2,8/0,7 4/1 1,4/0,3 1,8/0,4 2,2/0,6 2,8/0,7 4/1 6,5/1,8 3500/1750 3800/1900 4400/2200 4000/2000 4450/2225 5100/2550 5550/2775 5400/2700 5900/2950 6800/3400 7400/3700 8400/4200 5500/2750 6000/3000 7850/3925 8700/4350 9850/4925 10000/5000 11500/5750 11000/5500 12000/6000 14100/7050 15800/7900 16500/8250 20000/10000 66/50 67/53 71/55 64/50 68/52 69/54 72/56 63/48 66/50 69/63 70/55 73/58 58/44 59/44 64/48 65/50 68/53 69/54 70/55 58/43 60/45 65/49 66/50 67/51 71/56 45 47 49 53 54 55 61 76 78 79 83 85 92 93 98 100 104 106 110 130 135 149 151 155 169 R.R.P. € 1.374,30 1.393,20 1.442,70 1.442,30 1.457,20 1.542,90 1.586,10 1.634,40 1.647,00 1.707,50 1.747,20 1.843,80 2.014,70 2.069,30 2.099,20 2.160,90 2.272,10 2.290,10 2.470,50 2.541,20 2.572,20 2.719,60 2.760,80 2.903,10 3.124,30 53 SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE SUST Belt driven centrifugal cabinet fan 400ºC/2h MANUFACTURING FEATURES • Single inlet BST range fans, 400ºC/2h. • Fan assembled on antivibration mountings. • Supplied with motor, pulleys and belts. • Interchangeable panels to allow different fan positions. • Gland connection included. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. APPLICATIONS Designed for inline installation, indoor or outdoor assembly, they are suitable for: • Smoke emergency exhaust with motor outside the hazardous area. • Industrial and professional kitchen hoods. • Maximum working temperature: carried air 80ºC; environment 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. OUTSIDE ACCESSORIES RFS INT PE THREE PHASE RANGE Max. Curr. (A) 230 400 690 Model SUST 12/6 0,55kW SUST 12/6 0,75kW SUST 12/6 1,1kW SUST 12/6 1,5kW SUST 12/6 2,2kW SUST 15/7 0,55kW SUST 15/7 0,75kW SUST 15/7 1,1kW SUST 15/7 1,5kW SUST 15/7 2,2kW SUST 15/7 3kW SUST 15/7 4kW SUST 18/9 1,1kW SUST 18/9 1,5kW SUST 18/9 2,2kW SUST 18/9 3kW SUST 18/9 4kW SUST 18/9 5,5kW SUST 20/10 1,5kW SUST 20/10 2,2kW SUST 20/10 3kW SUST 20/10 4kW SUST 20/10 5,5kW SUST 20/10 7,5kW SUST 22/11 2,2kW SUST 22/11 3kW SUST 22/11 4kW SUST 22/11 5,5kW SUST 22/11 7,5kW SUST 22/11 11kW SUST 25/13 2,2kW SUST 25/13 3kW SUST 25/13 4kW SUST 25/13 5,5kW SUST 25/13 7,5kW SUST 25/13 11kW SUST 25/13 15kW SUST 30/14 3kW SUST 30/14 4kW SUST 30/14 5,5kW SUST 30/14 7,5kW SUST 30/14 11kW SUST 30/14 15kW 54 - 2,69 3,48 4,74 6,31 8,06 2,69 3,48 4,74 6,31 8,06 11,7 15,2 4,74 6,31 8,06 11,7 15,2 6,31 8,06 11,7 15,2 8,06 11,7 15,2 8,06 11,7 15,2 11,7 15,2 - 1,56 2,01 2,75 3,65 5 1,56 2,01 2,75 3,65 5 6,8 8,8 2,75 3,65 5 6,8 8,8 12 3,65 5 6,8 8,8 12 15 5 6,8 8,8 12 15 20,9 5 6,8 8,8 12 15 20,9 27,9 6,8 8,8 12 15 20,9 27,9 6,9 6,9 8,6 6,9 8,6 12,02 6,9 8,6 12,02 16,04 6,9 8,6 12,02 16,04 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,55 0,75 1,1 1,5 2,2 0,55 0,75 1,1 1,5 2,2 3 4 1,1 1,5 2,2 3 4 5,5 1,5 2,2 3 4 5,5 7,5 2,2 3 4 5,5 7,5 11 2,2 3 4 5,5 7,5 11 15 3 4 5,5 7,5 11 15 2900 3300 3900 4200 4800 3600 4800 6000 6500 7800 8500 9500 5000 6000 7500 8000 9000 10000 11000 13000 14000 15000 16500 19000 15000 16000 18000 20000 22000 23000 16500 19000 21000 24000 26000 29000 29500 18000 22000 25000 30000 33000 36000 72 75 78 80 85 68 74 72 76 82 84 87 82 83 87 88 89 92 79 83 86 88 92 94 77 79 82 85 87 92 71 74 76 78 83 86 89 74 76 78 82 85 87 73 74 77 80 85 91 92 95 98 103 106 109 110 114 119 122 125 140 203 208 211 214 227 235 219 222 225 238 246 273 251 254 257 270 278 305 324 328 331 344 352 379 398 R.R.P. € 1.425,60 1.440,80 1.524,80 1.575,20 1.635,40 1.557,80 1.570,60 1.654,60 1.705,10 1.765,40 1.898,40 2.154,70 1.825,50 1.876,00 1.936,20 2.069,50 2.540,70 2.805,10 2.900,40 2.960,60 3.093,70 3.564,90 3.829,20 4.388,70 3.191,40 3.324,30 3.795,80 4.046,50 4.548,30 4.977,90 3.339,20 3.549,10 4.020,30 4.271,10 4.773,00 5.202,70 6.498,80 4.164,10 4.547,40 4.798,50 5.578,50 5.729,20 7.026,00 SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE BOX BSTBF Belt driven backward centrifugal cabinet fan 400ºC/2h MANUFACTURING FEATURES • Single inlet BST range fans, BSTB 400ºC/2h • Fan assembled on antivibration mountings. • Supplied with motor, pulleys and belts. • Gland connection included. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Maximum working temperature: carried air 130ºC; environment 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Inlet in the opposite side, vertical inlet, blind inlet panel. • Variation of the transmission ratio. • Sandwich insulation. APPLICATIONS Designed for inline installation, indoor or outdoor assembly, they are suitable for: • Smoke emergency exhaust with motor outside the hazardous area. • Industrial and professional kitchen hoods. ACCESSORIES RFS INT OUTSIDE PE THREE PHASE RANGE Model BOX BSTBF 355 0,37kW BOX BSTBF 355 0,55kW BOX BSTBF 355 0,75kW BOX BSTBF 355 1,1kW BOX BSTBF 355 1,5kW BOX BSTBF 355 2,2kW BOX BSTBF 355 3kW BOX BSTBF 400 0,55kW BOX BSTBF 400 0,75kW BOX BSTBF 400 1,1kW BOX BSTBF 400 1,5kW BOX BSTBF 400 2,2kW BOX BSTBF 400 3kW BOX BSTBF 400 4kW BOX BSTBF 450 0,75kW BOX BSTBF 450 1,1kW BOX BSTBF 450 1,5kW BOX BSTBF 450 2,2kW BOX BSTBF 450 3kW BOX BSTBF 450 4kW BOX BSTBF 450 5,5kW BOX BSTBF 450 7,5kW BOX BSTBF 500 1,1kW BOX BSTBF 500 1,5kW BOX BSTBF 500 2,2kW BOX BSTBF 500 3kW BOX BSTBF 500 4kW BOX BSTBF 500 5,5kW BOX BSTBF 500 7,5kW BOX BSTBF 560 1,5kW BOX BSTBF 560 2,2kW BOX BSTBF 560 3kW BOX BSTBF 560 4kW BOX BSTBF 560 5,5kW BOX BSTBF 560 7,5kW BOX BSTBF 560 11kW 230 Max. Curr. (A) 400 690 Rated Power kW Air flow m3/h 1,94 2,69 3,48 4,74 6,31 8,06 11,7 2,69 3,48 4,74 6,31 8,06 11,7 15,2 3,48 4,74 6,31 8,06 11,7 15,2 4,74 6,31 8,06 11,7 15,2 6,31 8,06 11,7 15,2 - 1,12 1,56 2,01 2,75 3,65 5 6,8 1,56 2,01 2,75 3,65 5 6,8 8,8 2,01 2,75 3,65 5 6,8 8,8 12 15 2,75 3,65 5 6,8 8,8 12 15 3,65 5 6,8 8,8 12 15 20,9 6,9 8,6 6,9 8,6 6,9 8,6 12,02 0,37 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 1,5 2,2 3 4 0,75 1,1 1,5 2,2 3 4 5,5 7,5 1,1 1,5 2,2 3 4 5,5 7,5 1,5 2,2 3 4 5,5 7,5 11 3370 3850 4330 5050 5530 6010 6980 4350 5020 5360 6030 7370 8040 9460 5990 6490 7490 8490 9490 10490 11490 12980 7490 8850 9530 10890 12260 13620 14980 9550 11290 12160 13020 14760 16500 18230 R.R.P. € 1.696,30 1.724,90 1.741,60 1.745,20 1.797,90 1.827,00 1.850,60 1.897,20 1.908,80 1.915,30 1.961,30 1.998,60 2.029,30 2.095,60 2.173,80 2.179,30 2.226,30 2.248,20 2.296,00 2.355,80 2.511,00 2.674,80 2.489,80 2.539,90 2.558,80 2.604,70 2.663,50 2.817,60 3.001,50 3.239,20 3.216,80 3.279,10 3.411,30 3.368,80 3.707,90 3.899,50 55 SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE Model BOX BSTBF 630 2,2kW BOX BSTBF 630 3kW BOX BSTBF 630 4kW BOX BSTBF 630 5,5kW BOX BSTBF 630 7,5kW BOX BSTBF 630 11kW BOX BSTBF 630 15kW BOX BSTBF 710 3kW BOX BSTBF 710 4kW BOX BSTBF 710 5,5kW BOX BSTBF 710 7,5kW BOX BSTBF 710 11kW BOX BSTBF 710 15kW BOX BSTBF 710 18,5kW 56 230 Max. Curr. (A) 400 690 Rated Power kW Air flow m3/h 8,06 11,7 15,2 11,7 15,2 - 5 6,8 8,8 12 15 20,9 27,9 6,8 8,8 12 15 20,9 27,9 33 6,9 8,6 12,02 16,04 6,9 8,6 12,02 16,04 18,98 2,2 3 4 5,5 7,5 11 15 3 4 5,5 7,5 11 15 18,5 12720 13990 15260 16540 19080 21630 22900 18370 18370 20200 22960 25710 27550 31220 R.R.P. € 3.583,10 3.673,70 3.779,60 3.742,00 3.417,10 4.304,40 4.598,60 4.673,90 4.788,10 4.730,50 4.946,50 5.317,80 5.588,60 5.881,20 DOMESTIC RANGE DOMESTIC RANGE Axial and centrifugal exhaust fans with discharge at a single pipe, a ‘shunt’ duct or directly outside. Made of plastic, shock proof and thermal resistants. In compliance with the security standards of the thermal double insulation. Self greased bearings. Automatic shutter in standard series. ACCESSORIES UNDER REQUEST: applicable to all models of the DCB, DB and DAL ranges. Gravity guard Fixing rings Backdraft damper AXIAL EXTRACTORS Model DHS 160 DHS 190 DHS 225 DHS 300 DHS 350 DHS 400 R.P.M. max. Rated Power kW Air flow m3/h Sound dB (A) Weight Kg Diameter mm 1750 1500 1150 1050 1300 1400 0,020 0,030 0,040 0,050 0,110 0,250 450 700 900 1450 1850 3150 40 42 44 47 52 55 1,2 1,7 3 3,4 4,3 7,4 160 190 225 300 350 400 DHS 160 /190 / 225 / 300 R.R.P. € 54,60 58,60 73,30 103,60 254,40 380,50 DHS 350 / 400 CENTRIFUGAL BATH EXTRACTORS Model DCB-100 DCB 100 TIMER DCB-250 DCB 250 TIMER R.P.M. max. Rated Power kW Air flow m3/h 2300 2300 2500 2500 0,025 0,025 0,045 0,045 130 130 270 270 Ps mmH2O 13 13 23 23 Sound dB (A) Weight Kg Diameter mm 49 49 52 52 1 1 1,65 1,65 100 100 100/120* 100/120* R.R.P. € 74,90 104,90 151,80 213,20 * Adapter included that allows both diameters. DCB-250 / 250 TIMER DCB-100 / 100TIMER 57 DOMESTIC RANGE AXIAL BATH EXTRACTORS Model DB-8 DB-10 DB-12 DB-15 R.P.M. max. Rated Pow. kW Air flow m3/h 2500 2500 2450 2100 0,015 0,015 0,02 0,025 70 98 190 320 Ps mmH2O Sound dB (A) Weight Kg Diameter mm 39 41 43 43 39 41 43 43 90 100 120 150 3 3 5 8 R.R.P. € 36,60 36,80 51,80 69,60 Exclusive mounting system without screws. Backdraft shutter included.. UNDER REQUEST: DB TIMER models. DELUXE SERIES AXIAL BATH EXTRACTORS Model R.P.M. max. Rated Power kW Air flow m3/h DAL 10 STANDARD DAL 10 TIMER DAL 12 STANDARD DAL 12 TIMER DAL 15 STANDARD DAL 15 TIMER DAL 10 INOX DAL 10 INOX TIMER DAL 12 INOX DAL 12 INOX TIMER DAL 15 INOX DAL 15 INOX TIMER 2500 2500 2450 2450 2100 2100 2500 2500 2450 2450 2100 2100 0,015 0,015 0,020 0,020 0,025 0,025 0,015 0,015 0,020 0,020 0,025 0,025 98 98 190 190 320 320 98 98 190 190 320 320 Ps mmH2O 3 3 5 5 8 8 3 3 5 5 8 8 Sound dB (A) Weight Kg Diameter mm 38 38 40 40 42 42 38 38 40 40 42 42 0,64 0,64 0,84 0,84 1,02 1,02 0,66 0,66 0,87 0,87 1,04 1,04 100 100 120 120 150 150 100 100 120 120 150 150 R.R.P. € 49,80 83,30 67,80 103,00 91,30 128,80 62,40 102,80 91,30 128,80 109,20 150,10 KITCHEN EXTRACTORS Code 300523100 300403100 300655900 300656000 DG-400P 58 Model DG-400 P DG-600 DG-600 2V DG-750 R.P.M. max. Rated Power kW Air flow m3/h Sound dB (A) Weight Kg Diameter mm 2200 1180 1185 1200 0,060 0,105 0,105 0,125 290 480 420/600 700 52 50 52 49 2,02 4,8 4 5 110 110 118 118 DG-600 DG-600 2V R.R.P. € 83,60 132,50 135,80 150,90 DG-750 INDUSTRIAL VENTILATION AXIAL FANS LONG CASED AXIAL FANS CENTRIFUGAL LOW PRESSURE FANS CENTRIFUGAL MEDIUM PRESSURE FANS CENTRIFUGAL HIGH PRESSURE FANS www.casals.tv 59 AXIAL FANS HJEPA Square wall plate fan MANUFACTURING FEATURES • Polypropylene square plate reinforced with fiberglass. High resistance against corrosion. • Aluminium sheet impeller. • Supplied with motor support and protection guard according to the UNE-EN 294 standard. • Shadow coil asynchronous motor with Electromagnetic Compatibility Certification (EMC) according to the EN 55014, EN 61000-3-2 (95) and EN 61000-3-3 (95) Standards; rated Class F isolation and IP-42 protection according to the DIN40050 standard. ACCESSORIES REG INT PE RP0 PC APPLICATIONS Designed for wall assembly, they are suitable for: • Air renewal in all kind of closed environments. • Maximum working temperature: 50ºC. PCP SINGLE PHASE RANGE Code 265200103 265250103 265310103 265350103 60 Model HJEPA 20 M4 HJEPA 25 M4 HJEPA 30 M4 HJEPA 35 M4 R.P.M. max. 1300 1300 1300 1300 Max. Curr. (A) 230 400 0,2 0,35 0,55 0,7 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,03 0,056 0,077 0,075 500 900 1350 1825 37 42 47 50 1,5 2,5 3,5 4 R.R.P. € 95,20 110,30 134,00 160,10 AXIAL FANS HJBPA Square wall plate fan, variable pitch blades MANUFACTURING FEATURES • Polypropylene square plate reinforced with fiberglass. High resistance against corrosion. • Model 62 only available in steel sheet plate and epoxy powder finishing coat. • Variable pitch angle polyamide impeller reinforced with fiberglass. • Supplied with motor support and protection guard according to the ROHS 2002/95/EC Directive (Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipments). • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Terminal board with IP-65 protection. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors. ACCESSORIES REG RFS INT PE RP0 APPLICATIONS Designed for wall assembly, they are suitable for: • Air renewal in buildings and industries. • Maximum working temperature: single phase 50ºC, three phase 60ºC. UNDER REQUEST • B form impeller (air flow from impeller to motor), 100% reversible impeller and cast aluminium impeller. 5% additional cost. • 60Hz fans and special voltages. • Thermal protection. PC PCP SINGLE PHASE RANGE Code 268300103 268310103 268320103 268350103 268360103 268370103 268400103 268410103 268420103 268450106 266350103 266360103 300398900 266400103 266410103 300176300 266450103 266460103 Model HJBPA 30 M2/H 0,25kW HJBPA 30 M4/L 0,1kW HJBPA 30 M4/H 0,12kW HJBPA 35 M2/H 0,37kW HJBPA 35 M4/L 0,1kW HJBPA 35 M4/H 0,12kW HJBPA 40 M4/L 0,12kW HJBPA 40 M4/H 0,25kW HJBPA 40 M6/H 0,12kW HJB 45 M4/L 0,25kW HJB 45 M4/H 0,37kW HJB 45 M6/H 0,12kW HJB 50 M4/L 0,37kW HJB 50 M4/H 0,55kW HJB 50 M6/H 0,25kW HJB 56 M4/L 0,55kW HJB 56 M4/H 1,1kW HJB 56 M6/H 0,25kW R.P.M. max. 2800 1370 1400 2800 1370 1400 1400 1400 900 1400 1400 900 1400 1400 900 1400 1400 900 Max. Curr. (A) 230 400 2,73 0,83 1,1 2,73 0,83 1,1 1,1 1,1 1,05 2,02 2,77 1,05 2,77 4,25 2,07 4,25 7,45 2,07 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,25 0,1 0,12 0,37 0,1 0,12 0,12 0,25 0,12 0,25 0,37 0,12 0,37 0,55 0,25 0,55 1,1 0,25 3600 1950 2400 6000 2900 3400 4000 5200 3900 5900 7300 5400 7200 10200 6450 11000 13000 7900 72 51 54 75 55 59 60 62 54 64 65 58 66 69 60 71 73 61 6 5,5 5,6 7,5 6,5 6,6 7,5 7,7 9 12 12,5 13 14 15 18 19 22 19 R.R.P. € 276,60 263,50 292,20 312,10 287,70 301,20 291,30 313,60 341,40 418,90 425,00 415,90 484,70 504,30 475,00 516,60 541,80 526,90 THREE PHASE RANGE Code Model R.P.M. max. 268300106 268310106 268320106 268350106 268360106 268370106 268400106 268410106 268420106 300191800 266350106 266360106 300160200 266400106 266410106 300172600 266450106 266460106 HJBPA 30 T2/H 0,25kW HJBPA 30 T4/L 0,1kW HJBPA 30 T4/H 0,12kW HJBPA 35 T2/H 0,37kW HJBPA 35 T4/L 0,1kW HJBPA 35 T4/H 0,12kW HJBPA 40 T4/L 0,12kW HJBPA 40 T4/H 0,25kW HJBPA 40 T6/H 0,12kW HJB 45 T4/L 0,25kW HJB 45 T4/H 0,37kW HJB 45 T6/H 0,12kW HJB 50 T4/L 0,37kW HJB 50 T4/H 0,55kW HJB 50 T6/H 0,25kW HJB 56 T4/L 0,55kW HJB 56 T4/H 1,1kW HJB 56 T6/H 0,25kW 2800 1400 1400 2800 1400 1400 1400 1400 850 1400 1400 850 1400 1400 900 1400 1400 900 Max. Curr. (A) 230 400 1,65 0,67 0,84 1,65 0,67 0,84 0,84 1,44 1,08 1,44 1,94 1,08 1,94 2,69 1,51 2,69 4,74 1,51 0,95 0,39 0,48 0,95 0,39 0,48 0,48 0,83 0,62 0,83 1,12 0,62 1,12 1,56 0,87 1,56 2,75 0,87 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,25 0,1 0,12 0,37 0,1 0,12 0,12 0,25 0,12 0,25 0,37 0,12 0,37 0,55 0,25 0,55 1,1 0,25 3600 1950 2400 6000 2900 3400 4000 5200 3900 5900 7300 5400 7200 10200 6450 11000 13000 7900 72 51 54 75 55 59 60 62 54 64 65 58 66 69 60 71 73 61 6 5,5 5,6 7,5 6,5 6,6 7,5 7,7 9 12 12,5 13 14 15 18 19 22 19 R.R.P. € 266,00 256,90 267,20 305,80 285,50 285,50 285,30 305,20 336,90 408,80 417,20 404,70 480,40 482,00 466,60 483,80 501,30 476,70 61 AXIAL FANS HJRE Square wall plate, compact external rotor motor MANUFACTURING FEATURES • Steel sheet frame and impeller with epoxy powder finishing coat. • Supplied with motor support and protection guard according to the UNE-EN 20-359-74 standard. In compliance with the ROHS 2002/95/EC Directive (Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipments). • External rotor motor with IP-44 protection. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors. ACCESSORIES REG RFS INT PE PC APPLICATIONS Designed for wall assembly, they are suitable for: • Air renewal in buildings and industries. • Maximum working temperature: single phase 50ºC, three phase 55ºC. PCP SINGLE PHASE RANGE Model HJRE 35 M4 HJRE 40 M4 HJRE 45 M4 HJRE 50 M4 HJRE 56 M4 R.P.M. max. 1370 1350 1390 1360 1340 Max. Curr. (A) 230 400 0,68 0,81 1 1,7 2,23 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,15 0,18 0,25 0,42 0,53 3278 4510 6248 7150 9350 52 57 61 63 68 4,7 6,1 6,9 9,5 10,5 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,18 0,21 0,38 0,38 4510 6248 7150 9350 57 61 63 68 6,1 6,9 9,5 10,5 R.R.P. € 255,60 259,00 372,40 430,80 459,10 THREE PHASE RANGE Model HJRE 40 T4 HJRE 45 T4 HJRE 50 T4 HJRE 56 T4 62 R.P.M. max. 1380 1370 1370 1350 Max. Curr. (A) 230 400 0,43 0,52 0,97 0,97 0,74 0,9 1,68 1,68 R.R.P. € 253,40 363,30 426,90 429,90 AXIAL FANS HJB Wall axial belt driven fan for high flowrates and low RPM MANUFACTURING FEATURES • Casing made of galvanised steel sheet. • Equipped with gravity shutter. • Aluminium impeller. • Protection guard on pulley area. • Standard asynchronous squirrel-cage motor with IP-55 protection and class F insulation. Manufactured with standard voltage: 230/400V 50Hz. ACCESSORIES RFS INT APPLICATIONS Designed for wall assembly, they are suitable for: • Air renewal in buildings and industries. • Farms and greenhouses. • Maximum working temperature: 50ºC. PE SERIE TRIFÁSICA Code 266790106 266820106 266810162 Model R.P.M. max. HJB 80 T4 0,55kW HJB 100 T4 0,75kW HJB 120 T4 1,1kW 450 450 450 Max. Curr. (A) 230 400 2,8 3,5 4,8 1,6 2 2,8 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,55 0,75 1,1 30000 40000 45000 60 61 63 58 68 88 R.R.P. € 754,00 873,00 972,20 63 AXIAL FANS HA Wall plate compact, retro design MANUFACTURING FEATURES • Compact housing made of L-2630 aluminium (Al.8 Si 3 Cu), protected against corrosion with epoxy powder finishing coat. • Polyamide impeller with fixed pitch angle reinforced with fiberglass. • Standard asynchronous squirrel-cage motor with IP-54 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors. ACCESSORIES REG RFS INT PE RP0 RP1 APPLICATIONS Designed for wall assembly, they are suitable for: • Air renewal in buildings and industries. • Maximum working temperature: single phase 50ºC, three phase 60ºC. PC PCP SINGLE PHASE RANGE Code Model R.P.M. max. 262070120 262250103 262100120 262280103 262310103 262500103 HA 24 M2 0,06kW HA 24 M4 0,05kW HA 28 M2 0,08kW HA 28 M4 0,06kW HA 35 M4 0,08kW HA 35 M6 0,05kW 2870 1470 2800 1360 1370 970 Max. Curr. (A) 230 400 0,6 0,5 0,9 0,59 0,9 0,7 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,06 0,05 0,08 0,06 0,08 0,05 2100 980 2500 1500 3000 2000 65 50 70 52 60 47 3,5 3,5 3,5 3,5 5,5 5,5 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,06 0,05 0,08 0,06 0,37 0,08 0,05 2100 980 2500 1500 5500 3000 2000 65 50 70 52 77 60 47 3,5 3,5 3,5 3,5 6,5 5,5 5,5 R.R.P. € 219,00 221,80 224,40 227,30 271,10 302,50 THREE PHASE RANGE Code 262070106 262250106 262100106 262280106 262140106 262310106 262500106 64 Model HA 24 T2 0,06kW HA 24 T4 0,05kW HA 28 T2 0,08kW HA 28 T4 0,06kW HA 35 T2 0,37kW HA 35 T4 0,08kW HA 35 T6 0,05kW R.P.M. max. 2900 1480 2840 1400 2800 1400 980 Max. Curr. (A) 230 400 0,45 0,5 0,6 0,49 1,4 0,035 0,8 0,26 0,3 0,32 0,28 0,8 0,2 0,45 R.R.P. € 213,40 214,00 218,80 219,30 256,00 261,60 293,70 AXIAL FANS HB-HBA Wall plate, variable pitch blades MANUFACTURING FEATURES • Plate axial fan with circular reinforced frame. • Motor-impeller modular assembly for complete versatility. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase, motors up to 4kW and 400/690V 50Hz for higher powers. • HB: polyamide impeller with variable pitch angle reinforced with fiberglass • HBA: cast aluminium impeller with variable pitch angle. HB APPLICATIONS Designed for wall or duct installation, they are suitable for: • Air renewal in buildings and industries. • Maximum working temperature: single phase 50ºC, three phase 60ºC. UNDER REQUEST • B form impeller (air flow from impeller to motor), 100% reversible impeller. 5% additional cost. • 60Hz fans and special voltages. • Hot-dipped galvanised or stainless steel housing. • Optional square plate in circular frame. HBA ACCESSORIES REG RFS INT PE RP0 RP1 PC PCP MC HB SINGLE PHASE RANGE Code Model R.P.M. max. 260300x03 260310x03 260350x03 260360x03 260410x03 260470x03 260480x03 260500x03 260510x03 260560x03 260600x03 260680x03 260760x03 HB 30 M2 0,37kW HB 30 M4 0,12kW HB 35 M2 0,37kW HB 35 M4 0,12kW HB 40 M4 0,25kW HB 45 M4 0,37kW HB 45 M6 0,12kW HB 50 M4 0,55kW HB 50 M6 0,25kW HB 56 M4 0,55kW HB 56 M6 0,25kW HB 63 M6 0,37kW HB 71 M6 0,55kW 2800 1400 2800 1400 1400 1400 900 1400 900 1400 900 900 900 Max. Curr. (A) Rated Power kW 230 400 2,73 1,1 2,73 1,1 2,02 2,77 1,05 4,25 2,69 4,25 2,07 2,69 3,84 - Air flow m3/h Sound dB (A) Weight Kg 3100 1550 5200 2900 4700 7500 5200 10065 6000 11330 8680 11440 15400 71 56 77 60 64 68 54 70 58 73 61 63 68 7 7 11 10 17 15 14 17 18 21 19 24 29 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,37 0,12 0,37 0,12 1,10 0,25 1,50 2,20 0,37 0,12 0,55 0,25 0,55 0,75 1,10 1,50 3100 1550 5200 2900 8500 4700 12100 13500 7500 5200 10065 6000 11330 12650 13970 15600 71 56 77 60 84 64 85 87 67 54 70 58 73 74 75 76 5 4 10 9 15 11 23 26 15 14 17 18 19 22 26 28 0,37 0,12 0,37 0,12 0,25 0,37 0,12 0,55 0,25 0,55 0,25 0,37 0,55 R.R.P. € Polyamide 365,40 359,70 366,50 353,70 410,90 404,10 361,60 453,30 517,10 453,30 478,40 540,70 641,10 R.R.P. € Aluminium 416,50 410,10 417,80 403,20 468,40 476,90 426,70 534,90 610,20 534,90 564,50 638,00 756,40 THREE PHASE RANGE Code Model R.P.M. max. 260300x06 260310x06 260350x06 260360x06 260400x06 260410x06 260450x06 260460x06 260470x06 260480x06 260500x06 260510x06 260560x06 260570x06 260580x06 260590x06 HB 30 T2 0,37kW HB 30 T4 0,12kW HB 35 T2 0,37kW HB 35 T4 0,12kW HB 40 T2 1,1kW HB 40 T4 0,25kW HB 45 T2 1,5kW HB 45 T2 2,2kW HB 45 T4 0,37kW HB 45 T6 0,12kW HB 50 T4 0,55kW HB 50 T6 0,25kW HB 56 T4 0,55kW HB 56 T4 0,75kW HB 56 T4 1,1kW HB 56 T4 1,5kW 2800 1400 2800 1400 2800 1400 2800 2800 1400 850 1400 900 1400 1400 1400 1400 Max. Curr. (A) 230 400 690 1,65 0,84 1,65 0,84 4,42 1,44 6,01 8,61 1,94 1,08 2,69 1,51 2,69 3,48 4,74 6,31 0,95 0,48 0,95 0,48 2,55 0,83 3,48 4,98 1,12 0,62 1,56 0,87 1,56 2,01 2,75 3,65 - R.R.P. € Polyamide 344,60 338,50 345,40 334,50 429,70 390,10 450,90 518,90 374,20 334,90 402,60 478,80 419,80 452,10 480,80 534,00 R.R.P. € Aluminium 406,60 399,50 407,60 394,70 507,10 460,30 532,10 612,40 441,50 395,20 475,00 565,00 495,40 533,50 567,30 630,10 65 AXIAL FANS Code Model R.P.M. max. 260600x06 260610x06 260620x06 260630x06 260640x06 260650x06 260660x06 260670x06 260680x06 260690x06 260700x06 260710x06 260720x06 260730x06 260740x06 260760x06 260770x06 260780x06 260800x06 260810x06 260820x06 260830x06 260840x06 260850x06 260860x06 260900x06 260910x06 260920x06 260930x06 260940x06 260950x06 260960x06 260100x06 260110x06 260120x06 260130x06 260140x06 260150x06 260160x06 270020x06 270030x06 270040x06 270050x06 270060x06 270070x06 270080x06 270090x06 HB 56 T6 0,25kW HB 56 T6 0,37kW HB 56 T6 0,55kW HB 63 T4 0,75kW HB 63 T4 1,1kW HB 63 T4 1,5kW HB 63 T4 2,2kW HB 63 T4 3kW HB 63 T6 0,37kW HB 63 T6 0,55kW HB 63 T6 0,75kW HB 71 T4 1,1kW HB 71 T4 1,5kW HB 71 T4 2,2kW HB 71 T4 3kW HB 71 T6 0,55kW HB 71 T6 0,75kW HB 71 T6 1,1kW HB 80 T4 2,2kW HB 80 T4 3kW HB 80 T4 4kW HB 80 T6 0,75kW HB 80 T6 1,1kW HB 80 T6 1,5kW HB 80 T6 2,2kW HB 90 T4 3kW HB 90 T4 4kW HB 90 T4 5,5kW HB 90 T4 7,5kW HB 90 T6 1,5kW HB 90 T6 2,2kW HB 90 T6 3kW HB 100 T4 5,5kW HB 100 T4 7,5kW HB 100 T4 11kW HB 100 T4 15kW HB 100 T6 2,2kW HB 100 T6 3kW HB 100 T6 4kW HB 125 T4 11kW HB 125 T4 15kW HB 125 T4 18,5kW HB 125 T4 22kW HB 125 T6 3kW HB 125 T6 4kW HB 125 T6 7,5kW HB 125 T6 11kW 900 900 900 1400 1400 1400 1430 1430 900 900 910 1400 1400 1430 1430 900 910 910 1430 1430 1440 910 910 940 940 1430 1440 1440 1440 940 940 960 1440 1440 1460 1460 940 960 960 1460 1460 1465 1470 960 960 965 970 Max. Curr. (A) 230 400 690 1,51 2,13 2,85 3,48 4,74 6,31 8,06 11,7 2,13 2,85 4 4,74 6,31 8,06 11,7 2,85 4 5,5 8,06 11,7 15,2 4 5,5 6,9 9,7 11,7 15,2 6,9 9,7 12,4 9,7 12,4 16,3 12,4 16,3 - 0,87 1,23 1,65 2,01 2,75 3,65 5 6,8 1,23 1,65 2,3 2,75 3,65 5 6,8 1,65 2,3 3,2 5 6,8 8,8 2,3 3,2 4 5,6 6,8 8,8 12 15 4 5,6 7,2 12 15 20,9 27,9 5,6 7,2 9,4 20,9 27,9 33 38,5 7,2 9,4 16,1 22,4 6,9 8,6 6,9 8,6 12,02 16,04 12,02 16,04 18,98 22,14 9,26 12,88 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,25 0,37 0,55 0,75 1,10 1,50 2,20 3,00 0,37 0,55 0,75 1,10 1,50 2,20 3,00 0,55 0,75 1,10 2,20 3,00 4,00 0,75 1,10 1,50 2,20 3,00 4,00 5,50 7,50 1,50 2,20 3,00 5,50 7,50 11,00 15,00 2,20 3,00 4,00 11,00 15,00 18,20 22,00 3,00 4,00 7,50 11,00 8680 9500 10170 14080 16500 18620 21010 23430 11440 12430 13860 20570 22000 23870 27060 15400 17480 19640 29700 34980 38700 23100 25840 28600 30620 37540 44320 49370 55040 30580 35390 39910 53080 61590 66450 71510 37740 45690 51450 82600 89000 97300 103700 50000 55800 73600 88600 62 62 63 72 73 74 75 76 63 64 65 78 79 80 81 66 67 68 83 84 85 70 73 74 75 87 88 90 91 78 79 80 92 92 93 94 82 83 84 91 91 92 92 82 83 85 87 19 20 22 26 30 32 41 43 24 26 33 33 35 45 47 34 36 38 53 55 60 44 46 52 57 61 66 82 93 58 63 87 90 101 124 139 71 95 103 245 265 330 430 330 335 380 395 R.R.P. € Polyamide R.R.P. € Aluminium 442,90 504,90 553,40 491,30 537,10 638,80 731,30 759,90 469,90 568,90 491,30 531,50 646,10 770,40 804,40 605,60 629,10 667,90 904,40 934,50 1.051,40 793,70 845,40 869,90 956,60 1.040,50 1.047,20 1.215,50 1.321,90 923,40 1.004,60 1.168,20 1.395,50 1.544,70 2.160,00 2.270,70 1.339,30 1.500,40 1.732,00 3.242,40 3.378,40 3.725,80 3.927,20 2.618,20 2.844,60 3.242,40 3.398,50 522,70 595,80 653,00 579,70 633,80 753,80 863,00 896,60 554,40 671,30 579,70 627,10 762,40 909,00 949,20 714,60 742,30 788,10 1.067,20 1.102,70 1.240,60 936,60 997,50 1.026,40 1.128,80 1.227,80 1.235,70 1.434,20 1.559,80 1.089,60 1.185,40 1.378,40 1.646,70 1.822,80 2.548,80 2.679,50 1.580,30 1.770,50 2.043,70 3.826,10 3.986,60 4.396,50 4.634,10 3.089,40 3.356,70 3.826,10 4.010,20 R.R.P. € Polyamide R.R.P. € Aluminium THREE PHASE RANGE 2 SPEEDS Model R.P.M. max. HB 56 T4/T8 0,85-0,20kW HB 56 T4/T8 1,40-0,30kW HB 56 T4/T8 1,80-0,40kW HB 63 T4/T8 0,85-0,20kW HB 63 T4/T8 1,40-0,30kW HB 63 T4/T8 1,80-0,40kW HB 63 T4/T8 2,20-0,60kW HB 63 T4/T8 2,80-0,70kW HB 71 T4/T8 1,40-0,30kW HB 71 T4/T8 1,80-0,40kW HB 71 T4/T8 2,20-0,60kW HB 71 T4/T8 2,80-0,70kW HB 80 T4/T8 2,20-0,60kW HB 80 T4/T8 2,80-0,70kW HB 80 T4/T8 4,00-1,00kW HB 90 T4/T8 2,80-0,70kW HB 90 T4/T8 4,00-1,00kW HB 90 T4/T8 6,50-1,80kW HB 100 T4/T8 6,50-1,80kW HB 100 T4/T8 10,0-2,50kW HB 100 T4/T8 16,0-4,50kW 1380/685 1380/685 1375/695 1380/685 1380/685 1375/695 1420/690 1420/695 1380/685 1375/695 1420/690 1420/695 1420/690 1420/695 1420/695 1420/695 1420/695 1460/725 1460/725 1450/730 1470/730 x=1 Polyamide (HB) x=2 Aluminium (HBA) 66 Max. Curr. (A) 1500 750 2,33 2,33 4,44 2,33 2,33 4,44 5,34 6,3 2,33 4,44 5,34 6,3 5,34 6,3 6,3 6,3 6,3 13,9 13,9 20,2 29,9 0,88 0,88 1,43 0,88 0,88 1,43 2,18 2,42 0,88 1,43 2,18 2,42 2,18 2,42 2,42 2,42 2,42 5,62 5,62 6,6 11 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,85/0,2 1,4/0,3 1,8/0,4 0,85/0,2 1,4/0,3 1,8/0,4 2,2/0,6 2,8/0,7 1,4/0,3 1,8/0,4 2,2/0,6 2,8/0,7 2,2/0,6 2,8/0,7 4/1 2,8/0,7 4/1 6,5/1,8 6,5/1,8 10/2,5 16/4,5 12650/6325 13970/6985 15600/7800 14080/7040 16500/8250 18620/9310 21010/10505 23430/11715 20570/10285 22000/11000 23870/11935 27060/13530 29700/14850 34980/17490 38700/19350 37540/18770 44320/22160 49370/24685 53080/26540 66450/33225 71510/35755 73/57 74/58 76/60 71/59 72/60 74/62 75/63 76/64 78/64 79/65 79/66 80/67 81/67 82/68 83/69 85/70 86/71 88/73 89/71 90/72 91/72 22 26 28 26 30 32 41 42 33 35 45 46 53 54 59 60 65 87 96 117 138 580,30 608,00 664,00 773,90 793,10 836,70 933,40 991,40 769,00 802,80 894,70 967,30 1.112,40 1.199,30 1.281,70 1.305,70 1.354,20 1.842,60 2.123,20 2.490,70 3.231,60 780,60 817,90 893,30 1.040,90 1.066,90 1.125,60 1.255,60 1.333,70 1.034,50 1.079,90 1.203,60 1.301,20 1.496,40 1.613,50 1.724,10 1.756,70 1.821,70 2.478,80 3.350,60 4.347,30 5.624,90 LONG CASED AXIAL FANS HM-HMA Long cased variable pitch blades MANUFACTURING FEATURES • Reinforced fan casing manufactured in rolling steel sheet. • Motor-impeller modular assembly for complete versatility. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • HM: polyamide impeller with variable pitch angle reinforced with fiberglass • HMA: cast aluminium impeller with variable pitch angle. HM APPLICATIONS Designed for inline installation, they are suitable for: • Air renewal in buildings and industries. • Smoke extraction. • Maximum working temperature: single phase 50ºC, three phase 60ºC. UNDER REQUEST • 100% reversible impeller. 5% additional cost. • 60Hz fans and special voltages. 10% additional cost in three phase models. • Hot-dipped galvanised or stainless steel housing. HMA ACCESSORIES REG RFS INT PE RP AC PO BA-400 SIL-C R.R.P. € Polyamide SINGLE PHASE RANGE Code Model R.P.M. max. 263070x03 263270x03 263100x03 263290x03 263140x03 263310x03 261410x03 261470x03 261480x03 261500x03 261510x03 261560x03 261600x03 261680x03 261760x03 HM 25 M2 0,12kW HM 25 M4 0,08kW HM 30 M2 0,37kW HM 30 M4 0,12kW HM 35 M2 0,37kW HM 35 M4 0,12kW HM 40 M4 0,25kW HM 45 M4 0,37kW HM 45 M6 0,12kW HM 50 M4 0,55kW HM 50 M6 0,25kW HM 56 M4 0,55kW HM 56 M6 0,25kW HM 63 M6 0,37kW HM 71 M6 0,55kW 2770 1370 2800 1400 2800 1400 1400 1400 900 1400 900 1400 900 900 900 Max. Curr. (A) 230 400 0,98 0,9 2,73 1,1 2,73 1,1 2,02 2,77 1,05 4,25 2,07 4,25 2,07 2,69 3,84 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,12 0,08 0,37 0,12 0,37 0,12 0,25 0,37 0,12 0,55 0,25 0,55 0,25 0,37 0,55 2950 1100 3100 1550 5200 2900 4700 7500 5200 10065 6000 11330 8680 11440 15400 70 55 71 56 77 60 64 68 55 70 58 73 61 63 68 7 7 8 8 12 11 18 15 14 20 19 21 19 24 29 - 356,70 361,50 375,80 370,10 376,90 364,10 421,30 515,20 492,00 539,60 520,20 563,80 590,80 757,60 933,90 R.R.P. € Aluminium 406,70 412,10 428,40 422,00 429,70 415,10 480,30 587,30 560,90 615,10 593,00 642,70 673,50 863,70 1.064,70 THREE PHASE RANGE Code Model R.P.M. max. 263070x06 263270x06 263100x06 263290x06 263140x06 263310x06 261400x06 261410x06 261450x06 261460x06 261470x06 261480x06 261500x06 261510x06 HM 25 T2 0,12kW HM 25 T4 0,08kW HM 30 T2 0,37kW HM 30 T4 0,12kW HM 35 T2 0,37kW HM 35 T4 0,12kW HM 40 T2 1,1kW HM 40 T4 0,25kW HM 45 T2 1,5kW HM 45 T2 2,2kW HM 45 T4 0,37kW HM 45 T6 0,12kW HM 50 T4 0,55kW HM 50 T6 0,25kW 2800 1400 2800 1400 2800 1400 2800 1400 2800 2800 1400 850 1400 900 Max. Curr. (A) 230 400 690 0,67 0,035 1,65 0,84 1,65 0,84 4,42 1,44 6,01 8,61 1,94 1,08 2,69 2,13 0,38 0,2 0,95 0,48 0,95 0,48 2,55 0,83 3,48 4,98 1,12 0,62 1,56 1,23 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,12 0,08 0,37 0,12 0,37 0,12 1,1 0,25 1,5 2,2 0,37 0,12 0,55 0,25 2950 1100 3100 1550 5200 2900 8500 4700 12100 13500 7500 5200 10065 6000 70 55 71 56 77 60 84 64 86 88 67 54 69 61 7 7 8 8 12 11 20 18 22 23 20 21 25 23 R.R.P. € Polyamide 339,70 344,20 357,90 352,60 352,20 346,80 492,70 406,40 542,40 645,00 482,70 465,90 522,20 498,90 R.R.P. € Aluminium 387,20 392,40 408,00 401,90 401,60 395,40 561,70 463,30 618,30 735,30 550,20 531,10 595,30 568,70 67 LONG CASED AXIAL FANS Model R.P.M. max. HM 56 T4 0,55kW HM 56 T4 0,75kW HM 56 T4 1,1kW HM 56 T4 1,5kW HM 56 T6 0,25kW HM 56 T6 0,37kW HM 56 T6 0,55kW HM 63 T4 0,75kW HM 63 T4 1,1kW HM 63 T4 1,5kW HM 63 T4 2,2kW HM 63 T4 3kW HM 63 T6 0,37kW HM 63 T6 0,55kW HM 63 T6 0,75kW HM 71 T4 1,1kW HM 71 T4 1,5kW HM 71 T4 2,2kW HM 71 T4 3kW HM 71 T6 0,55kW HM 71 T6 0,75kW HM 71 T6 1,1kW HM 80 T4 2,2kW HM 80 T4 3kW HM 80 T4 4kW HM 80 T6 0,75kW HM 80 T6 1,1kW HM 80 T6 1,5kW HM 80 T6 2,2kW HM 90 T4 3kW HM 90 T4 4kW HM 90 T4 5,5kW HM 90 T4 7,5kW HM 90 T6 1,5kW HM 90 T6 2,2kW HM 90 T6 3kW HM 100 T4 5,5kW HM 100 T4 7,5kW HM 100 T4 11kW HM 100 T4 15kW HM 100 T6 2,2kW HM 100 T6 3kW HM 100 T6 4kW HM 125 T4 11kW HM 125 T4 15kW HM 125 T4 18,5kW HM 125 T4 22kW HM 125 T6 3kW HM 125 T6 4kW HM 125 T6 7,5kW HM 125 T6 11kW 1400 1400 1400 1400 900 900 900 1400 1400 1400 1430 1430 900 900 910 1400 1400 1430 1430 900 910 910 1430 1430 1440 910 910 940 940 1430 1440 1440 1440 940 940 960 1440 1440 1460 1460 940 960 960 1460 1460 1465 1470 960 960 965 970 Code 261560x06 261570x06 261580x06 261590x06 261600x06 261610x06 261620x06 261630x06 261640x06 261650x06 261660x06 261670x06 261680x06 261690x06 261700x06 261710x06 261720x06 261730x06 261740x06 261760x06 261770x06 261780x06 261800x06 261810x06 261820x06 261830x06 261840x06 261850x06 261860x06 261900x06 261910x06 261920x06 261930x06 261940x06 261950x06 261960x06 261100x06 261110x06 261120x06 261130x06 261140x06 261150x06 261160x06 271020x06 271030x06 271040x06 271050x06 271060x06 271070x06 271080x06 271090x06 Max. Curr. (A) 230 400 690 2,69 3,48 4,74 6,31 1,51 2,13 2,85 3,48 4,74 6,31 8,06 11,7 2,13 2,85 4 4,74 6,31 8,06 11,7 2,85 4 5,5 8,06 11,7 15,2 4 5,5 6,9 9,7 11,7 15,2 6,9 9,7 12,4 9,7 12,4 16,3 12,4 16,3 0 0 1,56 2,01 2,75 3,65 0,87 1,23 1,65 2,01 2,75 3,65 5 6,8 1,23 1,65 2,3 2,75 3,65 5 6,8 1,65 2,3 3,2 5 6,8 8,8 2,3 3,2 4 5,6 6,8 8,8 12 15 4 5,6 7,2 12 15 20,9 27,9 5,6 7,2 9,4 20,9 27,9 33 38,5 7,2 9,4 16,1 22,4 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,55 0,75 1,1 1,5 0,25 0,37 0,55 0,75 1,1 1,5 2,2 3 0,37 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 2,2 3 4 0,75 1,1 1,5 2,2 3 4 5,5 7,5 1,5 2,2 3 5,5 7,5 11 15 2,2 3 4 11 15 18,5 22 3 4 7,5 11 11330 12650 13970 15600 8680 9500 10170 14080 16500 18620 21010 23430 11440 12430 13860 20570 22000 23870 27060 15400 17480 19640 29700 34980 38700 23100 25840 28600 30620 37540 44320 49370 55040 30580 35390 39910 53080 61590 66450 71510 37740 45690 51450 82600 89000 97300 103700 50000 55800 73600 88600 73 74 75 76 62 62 63 72 73 74 75 76 63 64 65 78 79 80 81 66 67 68 83 84 85 70 73 74 75 87 88 90 91 78 79 80 92 92 93 94 82 83 84 91 91 92 92 77 78 80 82 28 29 33 35 23 27 29 37 41 43 54 56 35 37 44 45 48 63 65 41 48 50 68 70 75 59 61 67 72 87 92 107 118 84 89 112 120 131 155 170 101 125 133 235 255 320 420 320 325 370 385 6,9 8,6 6,9 8,6 12,02 16,04 12,02 16,04 18,98 22,14 9,26 12,88 R.R.P. € Polyamide 537,00 556,90 604,10 659,70 562,60 627,40 678,10 625,30 672,10 727,90 886,90 947,30 696,00 701,90 809,60 786,90 842,20 927,70 985,70 896,50 946,20 978,10 1.128,20 1.165,80 1.287,30 1.080,60 1.116,50 1.205,30 1.217,90 1.222,50 1.300,00 1.466,40 1.588,20 1.556,80 1.567,20 1.733,50 1.748,20 1.990,10 2.578,80 2.848,20 1.619,70 1.854,10 2.030,40 3.988,60 4.199,20 4.414,80 4.816,10 3.487,70 3.672,30 3.977,40 4.113,80 R.R.P. € Aluminium 612,10 634,90 688,70 752,10 641,40 715,30 773,00 712,90 766,20 829,80 1.011,10 1.079,90 793,40 800,20 922,90 897,10 960,10 1.057,50 1.123,70 1.022,00 1.078,70 1.115,00 1.286,10 1.329,00 1.467,50 1.231,90 1.272,80 1.374,00 1.388,40 1.393,60 1.482,00 1.671,80 1.810,60 1.774,80 1.786,60 1.976,10 1.992,90 2.268,70 2.939,80 3.247,00 1.846,50 2.113,60 2.314,60 4.547,00 4.787,10 5.032,90 5.490,40 3.976,00 4.186,40 4.534,20 4.689,70 THREE PHASE RANGE 2 SPEEDS Model HM 56 T4/T8 0,85-0,20kW HM 56 T4/T8 1,40-0,30kW HM 56 T4/T8 1,80-0,40kW HM 63 T4/T8 0,85-0,20kW HM 63 T4/T8 1,40-0,30kW HM 63 T4/T8 1,80-0,40kW HM 63 T4/T8 2,20-0,60kW HM 63 T4/T8 2,80-0,70kW HM 71 T4/T8 1,40-0,30kW HM 71 T4/T8 1,80-0,40kW HM 71 T4/T8 2,20-0,60kW HM 71 T4/T8 2,80-0,70kW HM 80 T4/T8 2,20-0,60kW HM 80 T4/T8 2,80-0,70kW HM 80 T4/T8 4,00-1,00kW HM 90 T4/T8 2,80-0,70kW HM 90 T4/T8 4,00-1,00kW HM 90 T4/T8 6,50-1,80kW HM 100 T4/T8 6,50-1,80kW HM 100 T4/T8 10,0-2,50kW x=1 Polyamide (HM) x=2 Aluminium (HMA) 68 R.P.M. max. Max. Curr. (A) 400V Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1380/685 1395/705 1375/695 1380/685 1395/705 1375/695 1420/690 1420/695 1395/705 1375/695 1420/690 1420/695 1420/690 1420/695 1435/695 1420/695 1435/695 1460/725 1460/725 1450/730 2,33/0,88 3,63/1,21 4,44/1,43 2,33/0,88 3,63/1,21 4,44/1,43 5,34/2,18 6,3/2,42 3,63/1,21 4,44/1,43 5,34/2,18 6,3/2,42 5,34/2,18 6,3/2,42 9,2/3,7 6,3/2,42 9,2/3,7 13,9/5,62 13,9/5,62 20,2/6,6 0,85/0,2 1,4/0,3 1,8/0,4 0,85/0,2 1,4/0,3 1,8/0,4 2,2/0,6 2,8/0,7 1,4/0,3 1,8/0,4 2,2/0,6 2,8/0,7 2,2/0,6 2,8/0,7 4/1 2,8/0,7 4/1 6,5/1,8 6,5/1,8 10/2,5 12650/6325 13970/6985 15600/7800 14080/7040 16500/8250 18620/9310 21010/10505 23430/11715 20570/10285 22000/11000 23870/11935 27060/13530 29700/14850 34980/17490 38700/19350 37540/18770 44320/22160 49370/24685 53080/26540 66450/33225 73/57 74/58 75/59 71/56 72/57 74/59 75/60 76/61 77/62 79/63 80/64 81/65 82/66 83/67 84/68 86/70 87/71 88/72 90/74 91/75 29 32 35 37 40 43 54 55 44 48 63 64 68 69 73 86 90 116 153 169 R.R.P. € Polyamide 728,40 754,50 819,60 931,50 957,60 1.022,70 1.126,90 1.211,80 993,10 1.058,20 1.162,60 1.247,40 1.353,90 1.438,60 1.536,50 1.502,10 1.599,80 2.186,70 3.230,70 4.091,40 R.R.P. € Aluminium 830,30 860,20 934,40 1.061,80 1.091,70 1.165,90 1.284,70 1.381,50 1.132,10 1.206,40 1.325,40 1.422,00 1.543,40 1.640,10 1.751,70 1.712,40 1.823,80 2.492,80 3.683,00 4.091,40 LONG CASED AXIAL FANS HI Mancooler, variable pitch blades MANUFACTURING FEATURES • Reinforced fan casing manufactured in rolling steel sheet. • Motor-impeller modular assembly for complete versatility. • Polyamide impeller with variable pitch angle reinforced with fiberglass • Epoxy powder finishing coat. • Protection guards on both sides of the fan according to the ROHS 2002/95/EC Directive (Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipments). • Airstream direction adjustable. • Fan support and protection guards supplied apart. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors. ACCESSORIES RFS INT APPLICATIONS Designed to be easily moved, they are suitable for: • Ventilation of working places. • Drying of pieces and surfaces. • Maximum working temperature: single phase 50ºC, three phase 60ºC. UNDER REQUEST • B form impeller (air flow from impeller to motor), 100% reversible impeller. 5% additional cost. • Aluminium impeller. • 60Hz fans and special voltages. 10% additional cost in three phase models. • 2 speed motors. • Flameproof and explosionproof fans with ATEX certified motors. • Hot-dipped galvanised or stainless steel housings. PE SINGLE PHASE RANGE Code HM 35+RP+PS HM 35+RP+PS HM 40+RP+PS HM 45+RP+PS HM 45+RP+PS HM 56+RP+PS HM 56+RP+PS HM 63+RP+PS HM 71+RP+PS Model R.P.M. max. HI 35 M2 0,37kW HI 35 M4 0,12kW HI 40 M4 0,25kW HI 45 M4 0,37kW HI 45 M6 0,12kW HI 56 M4 0,55kW HI 56 M6 0,25kW HI 63 M6 0,37kW HI 71 M6 0,55kW 2800 1400 1400 1400 900 1400 900 900 900 Max. Curr. (A) 230 400 2,73 1,1 2,02 2,77 1,05 4,25 2,07 2,69 3,84 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,37 0,12 0,25 0,37 0,12 0,55 0,25 0,37 0,55 5200 2900 4700 7500 5200 11330 8680 11440 15400 77 60 64 68 55 73 61 63 68 16 15 22 21 20 30 28 35 41 R.R.P. € 567,20 554,40 614,40 717,80 694,60 806,50 833,50 1.071,00 1.255,10 THREE PHASE RANGE Code HM 35+RP+PS HM 35+RP+PS HM 40+RP+PS HM 45+RP+PS HM 45+RP+PS HM 56+RP+PS HM 56+RP+PS HM 56+RP+PS HM 56+RP+PS HM 56+RP+PS HM 56+RP+PS HM 56+RP+PS HM 56+RP+PS HM 63+RP+PS HM 63+RP+PS HM 63+RP+PS HM 63+RP+PS HM 63+RP+PS HM 63+RP+PS HM 63+RP+PS HM 71+RP+PS HM 71+RP+PS HM 71+RP+PS HM 71+RP+PS HM 71+RP+PS HM 71+RP+PS HM 71+RP+PS Model HI 35 T2 0,37kW HI 35 T4 0,12kW HI 40 T4 0,25kW HI 45 T4 0,37kW HI 45 T6 0,25kW HI 56 T4 0,55kW HI 56 T4 0,75kW HI 56 T4 1,1kW HI 56 T4 1,5kW HI 56 T6 0,25kW HI 56 T6 0,37kW HI 56 T6 0,55kW HI 63 T4 0,75kW HI 63 T4 1,1kW HI 63 T4 1,5kW HI 63 T4 2,2kW HI 63 T4 3kW HI 63 T6 0,37kW HI 63 T6 0,55kW HI 63 T6 0,75kW HI 71 T4 1,1kW HI 71 T4 1,5kW HI 71 T4 2,2kW HI 71 T4 3kW HI 71 T6 0,55kW HI 71 T6 0,75kW HI 71 T6 1,1kW R.P.M. max. 2800 1400 1400 1400 900 1400 1400 1400 1400 900 900 900 1400 1400 1400 1430 1430 900 900 910 1400 1400 1430 1430 900 910 910 Max. Curr. (A) 230 400 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,65 0,84 1,44 1,94 1,51 2,69 3,48 4,74 6,31 1,51 2,13 2,85 3,48 4,74 6,31 8,06 11,7 2,13 2,85 4 4,74 6,31 8,06 11,7 2,85 4 5,5 0,95 0,48 0,83 1,12 0,87 1,56 2,01 2,75 3,65 0,87 1,23 1,65 2,01 2,75 3,65 5 6,8 1,23 1,65 2,3 2,75 3,65 5 6,8 1,65 2,3 3,2 0,37 0,12 0,25 0,37 0,25 0,55 0,75 1,1 1,5 0,25 0,37 0,55 0,75 1,1 1,5 2,2 3 0,37 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 5200 2900 4700 7500 5200 11330 12650 13970 15600 8680 9500 10170 14080 16500 18620 21010 23430 11440 12430 13860 20570 22000 23870 27060 15400 17480 19640 77 60 64 67 54 69 74 75 76 62 62 63 72 73 74 75 76 63 64 65 78 79 80 81 66 67 68 16 15 22 26 27 34 38 42 44 34 36 38 48 52 54 65 67 46 48 55 57 60 75 77 53 60 62 R.R.P. € 542,50 537,10 599,50 685,30 668,50 779,70 799,60 846,80 902,40 805,30 870,10 920,80 868,00 985,50 1.041,30 1.200,30 1.260,70 1.009,40 1.015,30 1.123,00 1.108,10 1.163,40 1.248,90 1.306,90 1.217,70 1.267,40 1.299,30 69 LONG CASED AXIAL FANS HH External motor, variable pitch blades MANUFACTURING FEATURES • Transmission ball bearings set inside a sealed box manufactured in steel or cast aluminium. Ball bearings permanently greased. • Cast aluminium impeller with variable pitch angle. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Inspection door for motor access and transmission set located on the lower part of the housing. • Maximum working temperature: carried air 110ºC; environment: 60ºC. UNDER REQUEST • B form impeller (air flow from impeller to motor), 100% reversible impeller. 5% additional cost. • Polyamide impeller. • 60Hz fans and special voltages. • 2 speed motors. • Flameproof and explosionproof fans with ATEX certified motors. • Hot-dipped galvanised or stainless steel housing. APPLICATIONS Designed for inline installation, they are suitable for: • Air renewal in buildings and industries. • Hot air extraction up to 110ºC. ACCESSORIES RFS INT PE RP AC PO BA-400 SIL-C THREE PHASE RANGE 70 Code Model R.P.M. max. 264100106 264310106 264340106 264340120 264380106 264380120 264390106 264400106 264420106 264420120 264440106 264450106 HH 35 T2 0,55kW HH 35 T4 0,12kW HH 45 T4 0,25kW HH 45 T4 0,37kW HH 56 T4 0,55kW HH 56 T4 0,75kW HH 56 T4 1,1kW HH 63 T4 1,1kW HH 71 T4 1,1kW HH 71 T4 1,5kW HH 90 T4 3kW HH 90 T4 5,5kW 2800 1400 1400 1400 1400 1400 1400 1400 1400 1400 1430 1440 Max. Curr. (A) 230 400 690 2,33 0,84 1,44 1,94 2,69 3,48 4,74 4,74 4,74 6,31 11,7 - 1,35 0,48 0,83 1,12 1,56 2,01 2,75 2,75 2,75 3,65 6,8 12 6,9 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,55 0,12 0,25 0,37 0,55 0,75 1,1 1,1 1,1 1,5 3 5,5 5040 2810 6310 7280 10990 12270 13550 16010 19950 21340 36410 47890 76 59 69 69 72 73 74 74 78 79 88 91 22 20 32 36 36 36 39 59 74 77 113 132 R.R.P. € 752,90 724,60 766,60 804,60 857,90 883,50 1.011,20 1.041,40 1.110,00 1.168,00 2.408,40 2.601,90 LONG CASED AXIAL FANS HHP External motor, split casing for maintenance, variable pitch blades MANUFACTURING FEATURES • Transmission ball bearings set inside a sealed box manufactured in steel or cast aluminium. Ball bearings permanently greased. • Cast aluminium impeller with variable pitch angle. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Fan opening option (180º) for easier maintenance and no need of disassembly from the installation. ACCESSORIES RFS INT PE RP AC PO APPLICATIONS Designed for inline installation, they are suitable for: • Air renewal in buildings and industries. • Hot air extraction up to 110ºC. • Maximum working temperature: carried air 110ºC; environment: 60ºC. UNDER REQUEST • B form impeller (air flow from impeller to motor), 100% reversible impeller. 5% additional cost. • Polyamide impeller. • 60Hz fans and special voltages. 10% additional cost in three phase models. • 2 speed motors. • Flameproof and explosionproof fans with ATEX certified motors. • Hot-dipped galvanised or stainless steel housing. BA-400 SIL-C THREE PHASE RANGE Code Model R.P.M. max. 264340160 264340161 264380160 264380161 264390160 264400160 264410160 264420160 264420161 264440160 264450160 264450161 HHP 45 T4 0,25kW HHP 45 T4 0,37kW HHP 56 T4 0,55kW HHP 56 T4 0,75kW HHP 56 T4 1,1kW HHP 63 T4 1,1kW HHP 63 T4 1,5kW HHP 71 T4 1,1kW HHP 71 T4 1,5kW HHP 90 T4 3kW HHP 90 T4 4kW HHP 90 T4 5,5kW 1400 1400 1400 1400 1400 1400 1400 1400 1400 1430 1440 1440 Max. Curr. (A) 230 400 690 1,44 1,94 2,69 3,48 4,74 4,74 6,31 4,74 6,31 11,7 15,2 - 0,83 1,12 1,56 2,01 2,75 2,75 3,65 2,75 3,65 6,8 8,8 12 6,9 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,25 0,37 0,55 0,75 1,1 1,1 1,5 1,1 1,5 3 4 5,5 6310 7280 10990 12270 13550 16010 18060 19950 21340 36410 42990 47890 69 69 72 73 74 74 78 78 79 88 89 91 32 36 36 36 39 59 63 74 77 113 118 132 R.R.P. € 988,10 1.005,20 1.011,60 1.035,50 1.057,60 1.343,00 1.391,60 1.443,90 1.491,40 2.909,00 3.244,40 3.273,40 71 CENTRIFUGAL LOW PRESSURE FANS BD-BD CUBIC Double inlet, IP55 closed motor MANUFACTURING FEATURES • Galvanised steel sheet housing. • Polyamide impeller reinforced with fiberglass in models 7/7, 9/9, 10/10 and 12/12. Galvanised steel sheet impeller in the rest of models. • Double inlet forward curved impeller in all models except 25/13, with single inlet. • Supplied with mounting feet (included in price) except cubic models, supported and reinforced by lateral plates. • BD CUBIC model supplied with fan support reinforced with squared wings for a major rigidity and solidity. • Motor fixing with an exclusive system designed by Casals through flexible arms and silent blocks to avoid vibration. Flexible arms in compliance with the ROHS 2002/95/EC Directive (Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipments). • Closed motors specially designed by Casals: extruded aluminium motor housing, wiring box fit in the motor with IP-65 protection. Motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50 Hz in single phase motors and 230/400V 50 Hz in three phase motors. • Motors with controllable voltage speed except three phase motors only controlled by frequency. BD APPLICATIONS Designed for assembly in equipment: • Ventilation boxes and air handling units. • Centrifugal heaters. • Industrial and professional kitchen hoods. • Maximum working temperature: 50ºC. UNDER REQUEST • 60Hz fans. • Fan assembly in the requested position. • Fan assembly with the requested power. BD CUBIC ACCESSORIES 72 REG RFS INT PE RA RM RI MBI CENTRIFUGAL LOW PRESSURE FANS SINGLE PHASE RANGE BD Code Model Equivalence cm R.P.M. max. 251100141 251160160 251350103 251260160 251220163 251220166 251280162 251280167 251330161 251320160 251370162 251370125 251600160 251600162 251520163 251520161 251520165 BD 7/7 M4 0,15kW BD 7/7 M6 0,08kW BD 9/5 M6 0,08kW BD 9/7 M6 0,15kW BD 9/9 M4 0,37kW BD 9/9 M4 0,55kW BD 9/9 M6 0,15kW BD 9/9 M6 0,25kW BD 10/8 M6 0,25kW BD 10/10 M4 0,55kW BD 10/10 M6 0,25kW BD 10/10 M6 0,37kW BD 12/9 M6 0,55kW BD 12/9 M6 0,75kW BD 12/12 M6 0,55kW BD 12/12 M6 0,75kW BD 12/12 M6 1,1kW 19/19 19/19 25/13 25/20 25/25 25/25 25/25 25/25 28/21 28/28 28/28 28/28 33/25 33/25 33/33 33/33 33/33 1300 860 860 850 1350 1350 850 900 900 1350 900 890 860 840 860 840 860 Max. Curr. (A) Rated Power kW 230 400 1,85 1,03 1,03 1,69 2,83 4,86 1,69 2,33 2,33 4,86 2,33 3,33 4,93 6,86 4,93 6,86 9,26 - 0,15 0,08 0,08 0,15 0,37 0,55 0,15 0,25 0,25 0,55 0,25 0,37 0,55 0,75 0,55 0,75 1,1 Air flow m3/h Sound dB (A) Weight Kg 1550 1400 980 2000 3400 3500 2600 2700 3400 4100 3400 3900 4800 6000 5700 6800 7900 60 52 55 57 64 66 60 62 64 66 64 64 67 67 67 67 69 7,5 7,3 11 12 14,8 15 14,5 14,7 14,9 16,5 15,5 16 20 21 25 25,5 28 Air flow m3/h Sound dB (A) Weight Kg 6900 7900 65 68 22 26 Air flow m3/h Sound dB (A) Weight Kg 12000 78 57 R.R.P. € 221,20 219,00 232,60 264,10 288,30 302,60 269,30 285,80 297,50 319,20 301,20 321,40 446,10 491,90 464,10 485,30 603,10 THREE PHASE RANGE BD Code Model Equivalence cm R.P.M. max. 251600161 251520160 BD 12/9 T6 1,1kW BD 12/12 T6 1,1kW 33/25 33/33 960 960 Max. Curr. (A) Rated Power kW 230 400 6,54 6,54 3,78 3,78 1,1 1,1 R.R.P. € 463,30 465,20 THREE PHASE RANGE BD CÚBIC Code Model Equivalence cm R.P.M. max. 252370106 BD 15/15 T6 2,2kW 39/39 900 Max. Curr. (A) Rated Power kW 230 400 10,92 6,31 2,2 R.R.P. € 868,00 73 CENTRIFUGAL LOW PRESSURE FANS BD 3V Double inlet, IP55 closed 3 speed motor MANUFACTURING FEATURES • Galvanised steel sheet housing. • Polyamide curved impeller reinforced with fiberglass in all models. • Supplied with mounting feet (included in price). • Motor fixing with an exclusive system designed by Casals through flexible arms and silent blocks to avoid vibration. Flexible arms in compliance with the ROHS 2002/95/EC Directive (Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipments). • Closed motors specially designed by Casals: extruded aluminium motor housing, wiring box fit in the motor with IP-65 protection. Motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50 Hz in three phase motors. • Thermal protector included. ACCESSORIES REG RFS INT INT 3V PE APPLICATIONS Designed for assembly in equipment: • Ventilation boxes and air handling units. • Centrifugal heaters. • Industrial and professional kitchen hoods. • Maximum working temperature: 50ºC. UNDER REQUEST • 60Hz fans. • Fan assembly in the requested position. RA RM RI MBI SINGLE PHASE RANGE Model BD 7/7 M4 0,15kW 3V BD 7/7 M6 0,08kW 3V BD 9/9 M4 0,37kW 3V BD 9/9 M6 0,15kW 3V BD 9/9 M6 0,25kW 3V BD 10/10 M4 0,55kW 3V BD 10/10 M6 0,25kW 3V BD 10/10 M6 0,37kW 3V BD 12/12 M6 0,55kW 3V BD 12/12 M6 0,75kW 3V 74 R.P.M. max. Max. C. (A) Equivalence Rated cm Speed 1 Speed 2 Speed 3 230 400 Power kW 19/19 19/19 25/25 25/25 25/25 28/28 28/28 28/28 33/33 33/33 1360 790 1400 800 900 1400 870 850 900 860 1266 736 1260 708 797 1216 744 738 864 812 1126 681 1167 646 697 1032 653 526 756 749 1,4 1 4,7 2,1 2,12 5,3 2,5 2,5 5,1 6 - 0,15 0,08 0,37 0,15 0,25 0,55 0,25 0,37 0,55 0,75 Air flow m3/h Sp 1 Sp 2 Sp 3 1450 1450 3000 2600 2710 3800 3600 3800 5000 5900 1350 1350 2700 2300 2400 3300 3080 3300 4800 5575 1200 1250 2500 2100 2100 2800 2700 2350 4200 5150 Sound dB (A) Weight Kg 60 52 64 57 57 66 64 57 67 67 9 9 18 18 18 25 24 25 27 27 R.R.P. € 267,40 265,30 354,10 307,60 323,50 368,60 340,70 368,60 515,00 540,40 CENTRIFUGAL LOW PRESSURE FANS BDE Double inlet, external rotor motor MANUFACTURING FEATURES • Fully made of galvanised steel sheet. • Double inlet forward curved impeller in all models. • Supplied with mounting feet (included in price). • External rotor motor and impeller assembled as a set, supported by fixing arms. • External rotor motor with IP-44 protection and Class F insulation according to the DIN 40.050 h1 Standard. Thermal contact protection, ball bearings permanently greased and 100% controllable voltage. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V in three phase motors. ACCESSORIES REG RFS INT PE RA APPLICATIONS Designed for assembly in equipment: • Ventilation boxes and air handling units. • Centrifugal heaters. • Industrial and professional kitchen hoods. • Maximum working temperature: 50ºC. RI MBI SINGLE PHASE RANGE Code Model Equivalence cm R.P.M. max. 251100140 251160140 251220140 251280140 251320140 251370140 251520140 BDE 7/7 M4 0,15kW BDE 7/7 M6 0,08kW BDE 9/9 M4 0,37kW BDE 9/9 M6 0,25kW BDE 10/10 M4 0,55kW BDE 10/10 M6 0,37kW BDE 12/12 M6 0,75kW 19/19 19/19 25/25 25/25 28/28 28/28 33/33 1300 860 1350 900 1350 890 840 Max. Curr. (A) Rated Power kW 230 400 1,85 1,03 2,83 2,33 4,86 3,33 6,86 - 0,15 0,08 0,37 0,25 0,55 0,37 0,75 Air flow m3/h Sound dB (A) Weight Kg 1500 1450 3450 2350 3800 4000 5500 55 47 59 52 61 59 60 8 8 16 16 20 20 29 Air flow m3/h Sound dB (A) Weight Kg 7500 63 29 R.R.P. € 531,00 525,30 673,10 627,90 794,60 792,50 1.042,10 THREE PHASE RANGE Code Model Equivalence cm R.P.M. max. 251520143 BDE 12/12 T6 1,1kW 12/12 960 Max. Curr. (A) Rated Power kW 230 400 6,54 3,78 1,1 R.R.P. € 1.006,10 75 CENTRIFUGAL LOW PRESSURE FANS BV-BVC-BVCR Double inlet, free shaft with no motor MANUFACTURING FEATURES • Galvanised steel sheet housing. • Double inlet forward curved impeller in all models • Transmission shaft with anticorrosion treatment. • Supplied with free shaft. • Transmission shaft standing out on both sides of the fan to allow motor, pulleys and belts assembly. • BV fan supplied with supports (included in price) except for sizes 39/39 and 47/47. • BV/BVC: Impellers made of polyamide reinforced with fiberglass for sizes 7/7, 9/9, 10/10 and 12/12; in other models made of galvanised steel sheet. Ball bearings permanently greased on rubber rings. • BVC/BVCR: Reinforced cubic assembly with lateral panels and a bearings base plate. • BVCR: Fan with reinforced structure and bridge bearings supported on the rigid structure. BV APPLICATIONS Designed for assembly in equipment: • Ventilation boxes and air handling units. • Centrifugal heaters. • Industrial and professional kitchen hoods. • Maximum working temperature: 60ºC. UNDER REQUEST • Fully equipped fan with motor, pulleys and belts. BVC BVCR ACCESSORIES BV ACCESSORIES BV 76 TM S RA MBI TM BS RA MBI Model Equivalence cm R.P.M. max. Max. Power CV Rated Power kW Air flow m3/h Weight Kg BV 7/7 BV 9/7 BV/BVC 9/9 BV 10/8 BV/BVC 10/10 BV 12/9 BV/BVC 12/12 BV/BVC/BVCR 15/15 BV/BVC/BVCR 18/18 BVCR 20/20 BVCR 22/22 BVCR 25/25 BVCR 30/28 19/19 25/20 25/25 28/21 28/28 33/25 33/33 39/39 47/47 51/51 56/56 63/63 76/71 2000 1500 1500 1300 1300 1200 1200 1100 900 800 700 550 450 1,5 2 2 2 3 4 4 5,5 7,5 10 10 15 20 1,1 1,5 1,5 1,5 2 3 3 4 5,5 7,5 7,5 11 15 3400 5500 6000 6700 7500 10000 11000 16000 25000 29000 32000 42000 62000 6 8 9 11 12 17 20 34 46 84 94 113 145 R.R.P. € BV 118,30 135,20 137,70 144,30 147,90 175,90 184,20 323,00 376,70 - R.R.P. € BVC 209,70 227,40 263,90 417,70 487,90 - R.R.P. € BVCR 540,70 680,20 1.041,40 1.139,30 1.112,80 1.639,70 CENTRIFUGAL LOW PRESSURE FANS BC Single inlet, standard B5 motor MANUFACTURING FEATURES • Galvanised steel sheet housing and epoxy powder finishing coat. • Single inlet forward curved impeller. • Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors, 230/400V 50Hz for three phase. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean air transport. • Maximum air working temperature: 130ºC in continuous. ACCESSORIES RFS INT PE RA AC EI BA-400 SIL-C SIL-R SINGLE PHASE RANGE Code Model R.P.M. max. 251200103 251360103 251670103 BC 25/10 M4 0,55kW BC 28/11 M4 1,1kW BC 35/18 M4 1,5kW 1400 1400 1400 Max. Curr. (A) 230 400 4,25 7,45 9,83 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,55 1,1 1,5 2200 3400 5200 64 68 78 17,5 29,5 34 R.R.P. € 471,60 568,20 704,60 THREE PHASE RANGE Code 251200106 251360106 251670106 251650106 Model BC 25/10 T4 0,55kW BC 28/11 T4 1,1kW BC 35/18 T4 1,5kW BC 35/18 T6 0,75kW R.P.M. max. 1400 1400 1400 910 Max. Curr. (A) 230 400 2,69 4,74 6,31 4 1,56 2,75 3,65 2,3 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,55 1,1 1,5 0,75 2200 3400 5200 4000 64 68 75 61 18 29,5 34 32 R.R.P. € 421,20 555,30 679,90 655,80 77 CENTRIFUGAL LOW PRESSURE FANS BST Single inlet, free shaft with no motor MANUFACTURING FEATURES • Fully made of galvanised steel sheet. • Simple inlet forward curved impeller in all models. • Transmission shaft with anticorrosion treatment. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Vertical discharge, circular pipes, blind cover. • Check prices with motor or transmission. • Totally assembled fan with motor, belts and pulleys. APPLICATIONS Designed for assembly in equipment: • Ventilation boxes and air handling units. • Centrifugal heaters. • Industrial and professional kitchen hoods. • Maximum working temperature: carried air 130ºC; environment: 60ºC. ACCESSORIES Model BST 9/4 BST 10/5 BST 12/6 BST 15/7 BST 18/9 BST 20/10 BST 22/11 BST 25/13 BST 30/14 78 RFS INT PE R.P.M. max. Air flow m3/h Weight Kg 1600 1500 1400 1050 1000 900 850 600 500 3200 4900 6500 9700 10800 20000 24000 29500 34000 9,6 11 17,5 22,5 33 71 80 93 125 R.R.P. € 257,30 269,30 314,60 358,90 434,40 926,10 1.000,00 1.167,10 1.401,10 CENTRIFUGAL MEDIUM PRESSURE FANS BCI Inflatable slides and castles MANUFACTURING FEATURES • Fully made of galvanised steel sheet. • Single inlet forward curved impeller in all models. • Portable box with anti-return valve. • Circular outlet for direct connection to duct or inflatable input. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz. • Default assembly position is LG270. ACCESSORIES RFS INT PE APPLICATIONS • Inflatable slides and castles. • Industrial applications, air extraction or injection. • Maximum working temperature: carried air 130ºC; environment: single phase 50ºC, three phase 60ºC. BA-400 SINGLE PHASE RANGE Code Model R.P.M. max. 253250103 253260103 253260120 253320103 BCI 20/8 M2 1,1kW BCI 22/9 M2 1,1kW BCI 22/9 M2 1,5kW BCI 25/10 M2 1,5kW 2800 2800 2800 2800 Max. Curr. (A) 230 400 7,02 7,02 9,44 9,44 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,1 1,1 1,5 1,5 1300 500 1100 700 60 70 70 75 27 38 39 45 R.R.P. € 777,20 785,10 823,60 834,70 79 CENTRIFUGAL MEDIUM PRESSURE FANS MA Radial aluminium impeller, steel sheet casing MANUFACTURING FEATURES • Rolling steel sheet housing. • Cast aluminium impeller. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean and slightly dusty air transport. ACCESSORIES RFS INT PE RA AC BA-400 SIL-C SIL-R SINGLE PHASE RANGE Code Model R.P.M. max. 253180162 253220162 253270162 MA 18 M2 0,1kW MA 24 M2 0,1kW MA 25 M2 0,18kW 2760 2760 2800 Max. Curr. (A) 230 400 0,81 0,81 1,48 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,09 0,09 0,18 295 350 560 60 65 68 6 7 11 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,09 0,09 0,18 295 350 560 60 65 68 6 7 11 R.R.P. € 269,00 304,90 359,40 THREE PHASE RANGE 80 Code Model R.P.M. max. 253180161 253220161 253270161 MA 18 T2 0,1kW MA 24 T2 0,1kW MA 25 T2 0,18kW 2800 2800 2800 Max. Curr. (A) 230 400 0,57 0,57 0,91 0,33 0,33 0,53 R.R.P. € 256,30 290,40 342,40 CENTRIFUGAL MEDIUM PRESSURE FANS MA Forward impeller, aluminium cast casing MANUFACTURING FEATURES • Cast aluminium housing. • Cast aluminium forward blades casing. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. ACCESSORIES RFS INT PE RA AC • Cooling of machines and parts. • Clean and slightly dusty air transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof and explosionproof fans with • ATEX certified motors. See ATEX section. BA-400 SIL-C SIL-R SINGLE PHASE RANGE Code Model R.P.M. max. 253300104 MA 26 M2 0,37kW 2800 Max. Curr. (A) 230 400 2,73 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,37 870 72 13 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,37 0,55 1,1 1,5 870 1100 2150 2550 71 80 80 83 13 14 20 27 R.R.P. € 400,80 THREE PHASE RANGE Code Model R.P.M. max. 253300106 253330106 253390106 253440106 MA 26 T2 0,37kW MA 27 T2 0,55kW MA 28 T2 1,1kW MA 31 T2 1,5kW 2800 2800 2800 2800 Max. Curr. (A) 230 400 690 1,65 2,33 4,42 6,01 0,95 1,35 2,55 3,48 - R.R.P. € 380,70 471,10 604,20 802,50 81 CENTRIFUGAL MEDIUM PRESSURE FANS MDE Forward impeller, external rotor motor MANUFACTURING FEATURES • Welded rolled steel sheet housing . • Galvanised steel sheet single inlet forward curved impeller. • Inlet protection guard included. • Epoxy powder finishing coat. • Asynchronous external rotor with IP-44 protection and Class B insulation according to the DIN 40.050 h1 Standard; greased for life ball bearings. Standard voltages: 230V 50Hz. ACCESSORIES REG INT APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean air transport. • Maximum working temperature: 50ºC. PE SINGLE PHASE RANGE Code 300712100 300712200 300712300 300712400 82 Model MDE 120 MDE 130 MDE 140 MDE 150 R.P.M. max. 2930 2890 2890 2900 Max. Curr. (A) 230 400 0,4 0,5 0,97 1 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,065 0,12 0,18 0,24 189 396 504 600 60 61 63 64 2,4 3 3,3 3,4 R.R.P. € 105,00 116,50 133,10 140,90 CENTRIFUGAL MEDIUM PRESSURE FANS MB Forward impeller MANUFACTURING FEATURES • Rolling steel sheet housing. • Completely joined or welded housing. • Galvanised steel sheet and single inlet forward curved impeller. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. MB 12/5 - 20/8 UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof and explosionproof fans with ATEX certified motors. See ATEX section. • Fans for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. • Fans provided with cooling disk for high temperatures. -MB 12/5-20/8: 105€ additional cost. -MB 22/9-28/11: 115€ additional cost. -MB 31/12-45/18: 125€ additional cost. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean air transport. • Maximum working temperature: carried air 130ºC; environment: single phase 50ºC, three phase 60ºC. MB 22/9 - 28/11 ACCESSORIES REG RFS AC MB 31/12 - 45/18 EI INT PE BA-400 SIL-C RA SIL-R SINGLE PHASE RANGE Code 253060103 253080103 253100103 253110103 253160103 253170103 253340103 253240103 253190103 253230103 Model R.P.M. max. MB 12/5 M2 0,1kW MB 12/5 M4 0,08kW MB 14/5 M2 0,25kW MB 16/6 M2 0,37kW MB 16/6 M4 0,18kW MB 18/7 M2 0,75kW MB 18/7 M4 0,25kW MB 20/6 M2 0,37kW MB 20/8 M2 1,1kW MB 20/8 M4 0,37kW 2760 1360 2800 2800 1400 2800 1400 2800 2800 1400 Max. Curr. (A) 230 400 0,81 0,59 1,96 2,73 1,62 5,15 2,02 2,73 7,02 2,77 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,09 0,08 0,25 0,37 0,18 0,75 0,25 0,37 1,1 0,37 510 320 1050 1400 1100 1900 1200 880 2100 2200 62 50 59 70 57 68 63 68 68 60 5 5 7 9,5 9,5 15 10 14 19 15 - R.R.P. € 159,80 172,70 188,20 192,90 198,50 350,10 343,40 388,10 404,10 365,40 THREE PHASE RANGE Code 253060106 253080106 253100106 253110106 253160106 253170106 253340106 Model MB 12/5 T2 0,1kW MB 12/5 T4 0,08kW MB 14/5 T2 0,25kW MB 16/6 T2 0,37kW MB 16/6 T4 0,18kW MB 18/7 T2 0,75kW MB 18/7 T4 0,25kW R.P.M. max. 2800 1400 2800 2800 1400 2800 1400 Max. Curr. (A) 230 400 690 0,57 0,49 1,17 1,65 1,12 3,03 1,44 0,33 0,28 1,68 0,95 0,65 1,75 0,83 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,09 0,08 0,25 0,37 0,18 0,75 0,25 510 320 1050 1400 1100 1900 1200 62 50 59 70 57 68 63 5 5 7 9,5 9,5 15 10 R.R.P. € 140,10 157,00 171,10 175,30 180,40 327,80 312,20 83 CENTRIFUGAL MEDIUM PRESSURE FANS Code Model R.P.M. max. 253240106 253190106 253230106 253210120 253200106 253200120 253280106 253290106 253310106 253360106 253370106 253380106 253450120 253450106 253480106 253480120 253510121 253510106 253510120 253530106 253530120 253530121 253560106 MB 20/6 T2 0,37kW MB 20/8 T2 1,1kW MB 20/8 T4 0,37kW MB 22/9 T2 1,1kW MB 22/9 T2 2,2kW MB 22/9 T4 0,55kW MB 25/10 T2 2,2kW MB 25/10 T2 3kW MB 25/10 T4 1,1kW MB 28/11 T2 4kW MB 28/11 T4 2,2kW MB 28/11 T6 0,75kW MB 31/12 T4 3kW MB 31/12 T4 4kW MB 35/14 T4 3kW MB 35/14 T4 5,5kW MB 40/16 T4 5,5kW MB 40/16 T4 7,5kW MB 40/16 T6 2,2kW MB 45/18 T4 5,5kW MB 45/18 T4 7,5kW MB 45/18 T4 11kW MB 45/18 T6 2,2kW 2800 2800 1400 2800 2800 1400 2800 2870 1400 2890 1430 910 1430 1440 1430 1440 1440 1440 940 1440 1440 1460 940 MZ Max. Curr. (A) 230 400 690 1,65 4,42 1,94 4,42 8,61 2,69 8,61 11,1 4,74 14,2 8,06 4 11,7 15,2 11,7 9,7 9,7 0,95 2,55 1,12 2,55 4,98 1,56 4,98 6,4 2,75 8,2 5 2,3 6,8 8,8 6,8 12 12 15 5,6 12 15 20,9 5,6 6,9 6,9 8,6 6,9 8,6 12,02 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,37 1,1 0,37 1,1 2,2 0,55 2,2 3 1,1 4 2,2 0,75 3 4 3 5,5 5,5 7,5 2,2 5,5 7,5 11 2,2 880 2100 2200 1800 3000 2700 2600 3200 3500 4000 5000 3600 5700 6800 6000 9000 9000 11000 7000 8000 11000 18000 9000 68 68 60 70 74 60 77 78 64 81 68 58 72 73 78 79 78 79 71 80 82 86 76 14 19 15 24 30 22 32 38 33 46 44 37 57 59 63 76 101 110 94 116 119 190 112 R.R.P. € 352,90 378,50 332,20 519,50 544,70 469,20 588,70 642,40 633,10 802,30 721,70 625,90 1.079,70 1.146,70 1.176,10 1.316,80 1.483,70 1.542,00 1.367,70 1.745,90 1.816,10 2.113,00 1.470,30 Forward impeller, free shaft without motor MANUFACTURING FEATURES • Rolling steel sheet housing. • Completely joined or welded housing. • Galvanised steel sheet single inlet forward curved impeller. • Standard fan supplied with free shaft, i.e. without motor, pulleys or belts. • Epoxy powder finishing coat. UNDER REQUEST • Fully equipped fans, including motor, pulleys, belts, belt and shaft guard. Mounted on a base plate or an upper plate. • Flameproof and explosionproof fans with ATEX certified motors. • Fans for air working temperatures up to 350ºC. • Hot-dipped galvanised or stainless steel fans. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean air transport. • Maximum working temperature: carried air 200ºC; environment: 60ºC. UNDER REQUEST ACCESSORIES Code 254120160 254180160 254210160 254230160 254330160 254370160 254420160 254540160 84 Model MZ 22/9 MZ 25/10 MZ 28/11 MZ 31/12 MZ 35/14 MZ 40/16 MZ 45/18 MZ 63/25 REG RFS INT PE RA R.P.M. max. Rated Power máx. kW Air flow m3/h 3400 3000 2850 2425 1900 1650 1510 960 3 4 5,5 7,5 7,5 11 11 22 4000 5200 6900 8500 11000 14000 17000 32000 AC EI P. máx. Ps (mm H2O) 220 220 230 250 200 190 200 180 BA-400 Weight Kg 18 24 27 40 56 71 85 115 SIL-C SIL-R R.R.P. € 596,80 679,30 731,70 1.130,50 1.447,80 1.288,00 1.582,60 3.390,00 CENTRIFUGAL MEDIUM PRESSURE FANS MBCA Forward impeller MANUFACTURING FEATURES • Completely joined or welded rolling steel sheet housing. • Single inlet forward curved impeller in galvanised sheet. • Epoxy powder finishing coat. • Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230/400V 50Hz up to 4kW, and 400/690V 50Hz for higher powers. • Cooling of machines and parts. • Clean air transport. • Maximum working temperature: carried air 130ºC; environment 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. • Fans for air working high temperatures. • Hot-dipped galvanised or stainless steel fans. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. THREE PHASE RANGE Model R.P.M. max. MBCA 180 T2 0,55kW MBCA 180 T2 1,1kW MBCA 200 T2 1,1kW MBCA 200 T2 2,2kW MBCA 220 T2 1,5kW MBCA 220 T2 3kW MBCA 250 T2 3kW MBCA 280 T2 5,5kW MBCA 280 T2 11kW MBCA 220 T4 0,18kW MBCA 220 T4 0,37kW MBCA 250 T4 0,25kW MBCA 250 T4 0,55kW MBCA 280 T4 0,55kW MBCA 280 T4 0,75kW MBCA 280 T4 1,1kW MBCA 310 T4 1,1kW MBCA 310 T4 1,5kW MBCA 310 T4 2,2kW MBCA 350 T4 2,2kW MBCA 350 T4 3kW MBCA 350 T4 4kW MBCA 400 T4 4kW MBCA 400 T4 5,5kW MBCA 400 T4 7,5kW MBCA 450 T4 11kW MBCA 450 T4 15kW MBCA 500 T4 15kW MBCA 500 T4 22kW MBCA 560 T4 22kW MBCA 560 T4 37kW MBCA 310 T6 0,37kW MBCA 310 T6 0,55kW MBCA 350 T6 0,75kW MBCA 350 T6 1,1kW MBCA 400 T6 1,5kW MBCA 400 T6 2,2kW MBCA 450 T6 3kW MBCA 450 T6 4kW MBCA 500 T6 4kW MBCA 500 T6 7,5kW MBCA 560 T6 7,5kW MBCA 560 T6 11kW 2800 2800 2800 2800 2800 2870 2870 2900 2930 1400 1400 1400 1400 1400 1400 1400 1400 1400 1430 1430 1430 1440 1440 1440 1440 1460 1460 1460 1470 1470 1475 900 900 910 910 940 940 960 960 960 965 965 970 Max. Curr. (A) 230 400 690 2,33 4,42 4,42 8,61 6,01 11,1 11,1 1,12 1,94 1,44 2,69 2,69 3,48 4,74 4,74 6,31 8,06 8,06 11,7 15,2 15,2 2,13 2,85 4 5,5 6,9 9,7 12,4 16,3 16,3 - 1,35 2,55 2,55 4,98 3,48 6,4 6,4 11 19,8 0,65 1,12 0,83 1,56 1,56 2,01 2,75 2,75 3,65 5 5 6,8 8,8 8,8 12 15 20,9 27,9 27,9 38,5 38,5 66,7 1,23 1,65 2,3 3,2 4 5,6 7,2 9,4 9,4 16,1 16,1 22,4 6,3 11,39 6,9 8,6 12,02 16,04 16,04 22,14 22,14 38,35 9,26 9,26 12,88 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,55 1,1 1,1 2,2 1,5 3 3 5,5 11 0,18 0,37 0,25 0,55 0,55 11 1,1 1,1 1,5 2,2 2,2 3 4 4 5,5 7,5 11 15 15 22 22 37 0,37 0,55 0,75 1,1 1,5 2,2 3 4 4 7,5 7,5 11 1190 1900 1700 3050 2150 3850 3450 4750 7650 1080 1900 1330 2400 2150 3050 3850 3050 4250 6150 4750 6150 8500 7650 9500 12000 12000 19000 17000 24200 21600 34200 2400 3850 4250 5400 6150 8500 9500 12000 10800 17000 15300 21600 74 76 78 79 80 81 87 89 90 63 63 64 66 68 70 70 73 74 74 76 77 78 81 82 82 83 85 87 89 89 90 63 64 66 68 68 71 73 74 78 80 81 82 18 21 30 37 36 47 49 72 78 28 30 34 37 42 44 46 57 60 62 76 78 87 109 98 119 129 168 187 227 236 382 50 53 70 72 93 99 114 130 174 187 199 212 R.R.P. € 536,80 594,00 693,00 742,60 752,50 851,80 934,90 1.244,60 1.616,70 642,50 669,50 733,40 786,00 841,40 856,90 884,90 952,10 970,70 1.032,70 1.123,80 1.151,70 1.232,30 1.430,20 1.600,70 1.690,20 2.259,70 2.359,70 2.680,20 3.087,10 3.522,50 4.496,50 908,00 919,50 1.043,20 1.064,90 1.343,40 1.432,60 1.827,50 1.901,90 2.222,50 2.580,20 3.015,60 3.115,60 85 CENTRIFUGAL MEDIUM PRESSURE FANS MBC/FA Forward impeller, cubic casing MANUFACTURING FEATURES • Reinforced rolling steel sheet housings completely welded (internally and externally) with epoxy powder finishing coat. • Forward curved reinforced impeller. • Standard asynchronous squirrel-cage motor with IP55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. peratures. • Clean air transport. • Maximum working temperature: carried air up to 250ºC; environment: single phase 50ºC, three phase 60ºC. UNDER REQUEST • Drain plug and inspection door. • 60Hz fans and special voltages. • Hot air transport. • 2 speed motors. APPLICATIONS Designed for inline installation, they are suitable for: • Smoke emergency exhaust with motor outside the hazardous area. • Hot air exhaust in ovens or facilities with high tem- ACCESSORIES RFS INT PE AC EI BA-400 SIL-C SIL-R SINGLE PHASE RANGE Code Model R.P.M. max. Max. Curr. (A) Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 253310173 253300173 253380173 MBC/FA 25/10 M4 1,1kW MBC/FA 25/10 M6 0,55kW MBC/FA 28/11 M6 0,75kW 1400 900 900 7,45 3,84 4,97 1,1 0,55 0,75 3500 1900 3600 70 62 60 63 61 67 R.R.P. € 830,30 810,60 870,80 THREE PHASE RANGE Code 253310186 253300186 253360186 253370186 253380186 253460186 253450186 253430186 253480186 253490186 253470186 253510186 253520186 253500186 253530186 253540186 253560186 86 Model MBC/FA 25/10 T4 1,1kW MBC/FA 25/10 T6 0,55kW MBC/FA 28/11 T2 4kW MBC/FA 28/11 T4 2,2kW MBC/FA 28/11 T6 0,75kW MBC/FA 31/12 T4 3kW MBC/FA 31/12 T4 4kW MBC/FA 31/12 T6 1,5kW MBC/FA 35/14 T4 3kW MBC/FA 35/14 T4 5,5kW MBC/FA 35/14 T6 1,5kW MBC/FA 40/16 T4 5,5kW MBC/FA 40/16 T4 7,5kW MBC/FA 40/16 T6 2,2kW MBC/FA 45/18 T4 5,5kW MBC/FA 45/18 T4 7,5kW MBC/FA 45/18 T6 2,2kW R.P.M. max. 1400 900 2890 1430 910 1430 1440 940 1430 1440 940 1440 1440 940 1440 1440 940 Max. Curr. (A) 230 400 690 4,74 2,85 14,2 8,06 4 11,7 15,2 6,9 11,7 6,9 9,7 9,7 2,75 1,65 8,2 5 2,3 6,8 8,8 4 6,8 12 4 12 15 5,6 12 15 5,6 6,9 6,9 8,6 6,9 8,6 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,1 0,55 4 2,2 0,75 3 4 1,5 3 5,5 1,5 5,5 7,5 2,2 5,5 7,5 2,2 3500 1900 4000 5000 3600 5700 6800 4500 6000 8700 5500 9000 10500 7000 8000 11000 9000 70 62 81 82 60 72 73 66 78 79 70 78 79 71 80 82 76 64 63 66 75 69 72 73 71 75 79 73 87 89 86 91 93 90 R.R.P. € 786,00 739,40 1.020,70 942,40 833,80 1.298,80 1.341,30 1.131,70 1.245,90 1.459,60 1.190,20 1.643,60 1.851,70 1.404,20 1.799,10 2.007,30 1.538,70 CENTRIFUGAL MEDIUM PRESSURE FANS MA P/R Radial impeller, aluminium cast MANUFACTURING FEATURES • Cast aluminium housing. • Straight blade steel sheet or cast aluminium impellers. • Epoxy powder finishing coat. • Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230/400V 50Hz. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. APPLICATIONS Designed for inline installation, they are suitable for: • Solid material transport (except for textile fibers). • Maximum working temperature: carried air 130ºC; environment: 60ºC. ACCESSORIES RFS INT PE AC BA-400 SIL-C SIL-R THREE PHASE RANGE Code Model R.P.M. max. 253300160 300006000 300140600 300032600 MA 26 T2 0,37kW P/R MA 27 T2 0,55kW P/R MA 28 T2 0,75kW P/R MA 31 T2 1,5kW P/R 2800 2800 2800 2800 Max. Curr. (A) 230 400 1,65 2,33 3,03 6,01 0,95 1,35 1,75 3,48 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,37 0,55 0,75 1,5 700 850 1400 1800 75 80 81 83 14 16 21 25 R.R.P. € 485,40 559,60 707,20 915,20 87 CENTRIFUGAL MEDIUM PRESSURE FANS MB P/R Radial impeller MANUFACTURING FEATURES • Rolled steel sheet housing. • Single inlet straight blade impeller manufactured in steel sheet and with reinforced with a welded ring protected with epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and rated class F insulation. Manufactured with standard voltages 230V 50Hz for single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof and explosionproof fans with ATEX certified motors. • Hot-dipped galvanised or stainless steel fans. • Fans provided with cooling disk for high temperatures. 120€ additional cost. • Fans for air working temperatures up to 250ºC. APPLICATIONS Designed for inline installation, they are suitable for: • Solid material transport (except for textile fibers). • Maximum working temperature: carried air 130ºC; environment: 60ºC. ACCESSORIES RFS INT PE AC EI BA-400 SIL-C SIL-R THREE PHASE RANGE 88 Code Model R.P.M. max. 253210160 253280160 253360161 253450160 253480161 253510160 253530160 253530161 MB 22/9 T2 1,1kW P/R MB 25/10 T2 1,5kW P/R MB 28/11 T2 2,2kW P/R MB 31/12 T2 3kW P/R MB 35/14 T2 5,5kW P/R MB 40/16 T2 7,5kW P/R MB 45/18 T2 11kW P/R MB 45/18 T2 15kW P/R 2800 2800 2800 2870 2900 2900 2930 2930 Max. Curr. (A) 230 400 690 4,42 6,01 8,61 11,1 - 2,55 3,48 4,98 6,4 11 15 19,8 26,6 6,3 8,6 11,39 15,3 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,1 1,5 2,2 3 5,5 7,5 11 15 2100 2850 4500 5300 7800 9500 10500 12500 70 74 76 79 84 90 92 95 23 31 40 55 85 103 180 191 R.R.P. € 828,80 886,70 967,20 1.250,80 1.683,90 1.874,00 2.482,30 3.035,90 CENTRIFUGAL MEDIUM PRESSURE FANS MBZM P/R Radial impeller MANUFACTURING FEATURES • Rolled steel sheet housing. • Fully welded and reinforced housing. • Single inlet straight blade impeller manufactured in steel sheet with epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors, 230/400V 50Hz for three phase, motors up to 4kW and 400/690V 50Hz for higher powers. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. • Fan for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. APPLICATIONS Designed for inline installation, they are suitable for: • Solid material and textile fibers transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. ACCESSORIES RFS INT PE AC EI BA-400 SIL-C SIL-R THREE PHASE RANGE Model R.P.M. max. MBZM 220 T2 0,37kW P/R MBZM 251 T2 0,55kW P/R MBZM 252 T2 0,75kW P/R MBZM 281 T2 1,1kW P/R MBZM 282 T2 1,5kW P/R MBZM 311 T2 1,5kW P/R MBZM 312 T2 2,2kW P/R MBZM 351 T2 3kW P/R MBZM 352 T2 4kW P/R MBZM 401 T2 5,5kW P/R MBZM 402 T2 7,5kW P/R MBZM 452 T2 11kW P/R MBZM 501 T2 15kW P/R MBZM 502 T2 22kW P/R MBZM 454 T4 1,5kW P/R MBZM 503 T4 2,2kW P/R MBZM 504 T4 3kW P/R MBZM 561 T4 4kW P/R MBZM 562 T4 5,5kW P/R MBZM 631 T4 7,5kW P/R MBZM 632 T4 11kW P/R MBZM 711 T4 11kW P/R MBZM 712 T4 15kW P/R MBZM 801 T4 18,5kW P/R MBZM 802 T4 30kW P/R MBZM 901 T4 37kW P/R MBZM 902 T4 45kW P/R MBZM 1001 T4 60kW P/R MBZM 1002 T4 75kW P/R 2800 2800 2800 2800 2800 2800 2800 2870 2890 2900 2900 2930 2930 2940 1400 1430 1430 1440 1440 1440 1460 1460 1460 1465 1475 1475 1475 1480 1480 Max. Curr. (A) 230 400 690 1,65 2,33 3,03 4,42 6,01 6,01 8,61 11,1 14,2 6,31 8,06 11,7 15,2 - 0,95 1,35 1,75 2,55 3,48 3,48 4,98 6,4 8,2 11 15 19,8 26,6 39 3,65 5 6,8 8,8 12 15 20,9 20,9 27,9 33 53,2 66,7 78,6 96,2 130 6,3 8,6 11,39 15,3 22,43 6,9 8,6 12,02 12,02 16,04 18,98 30,59 38,35 45,2 55,32 74,75 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,37 0,55 0,75 1,1 1,5 1,5 2,2 3 4 5,5 7,5 11 15 22 1,5 2,2 3 4 5,5 7,5 11 11 15 18,5 30 37 45 55 75 1116 1116 1548 1548 2196 2196 3096 3096 4320 4320 6120 8280 8280 11880 4320 4320 6120 6120 8280 8280 11880 11880 16920 16920 23760 23760 33840 33840 46800 69 71 72 73 74 76 77 79 80 83 84 87 90 91 71 72 74 75 76 78 80 83 84 85 87 90 92 96 97 11 26 29 33 37 43 46 74 80 109 115 198 222 274 106 126 134 148 175 200 274 338 368 443 509 598 638 800 918 R.R.P. € 493,60 548,70 590,50 689,00 716,90 760,40 782,20 1.022,00 1.087,10 1.521,60 1.577,40 2.139,10 2.390,30 2.855,80 1.425,90 1.697,60 1.725,60 2.581,90 2.752,40 3.249,50 3.573,60 4.329,50 4.429,50 5.262,00 5.909,20 7.567,60 7.898,70 9.296,90 10.369,40 89 CENTRIFUGAL MEDIUM PRESSURE FANS MBR Backward impeller MANUFACTURING FEATURES • Reinforced rolling steel sheet housings with epoxy powder coat finishing. • Reinforced high efficiency backward curved impeller. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motor. • Flameproof and explosionproof fans with ATEX certified motors. • Fans for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean and slightly dusty air transport. • Exhaust after filters, separators and cyclones. • Pneumatic transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. ACCESSORIES RFS INT PE AC EI BA-400 SIL-C SIL-R THREE PHASE RANGE 90 Code Model R.P.M. max. 243310106 243350106 243410106 243400106 243450106 243510106 243500106 243570106 243560106 243650106 243640106 243630106 243730106 243720106 243710106 MBR 31/10 T2 1,1kW MBR 35/11 T2 2,2kW MBR 40/12 T2 3kW MBR 40/12 T4 0,75kW MBR 45/14 T4 1,1kW MBR 50/16 T4 1,5kW MBR 50/16 T6 0,75kW MBR 56/18 T4 3kW MBR 56/18 T6 1,5kW MBR 63/20 T4 5,5kW MBR 63/20 T6 1,5kW MBR 63/20 T8 1,1kW MBR 71/22 T4 7,5kW MBR 71/22 T6 3kW MBR 71/22 T8 1,5kW 2800 2800 2870 1400 1400 1400 910 1430 940 1440 940 710 1440 960 710 Max. Curr. (A) 230 400 690 4,42 8,61 11,1 3,48 4,74 6,31 4 11,7 6,9 6,9 5,54 12,4 7,45 2,55 4,98 6,4 2,01 2,75 3,65 2,3 6,8 4 12 4 3,2 15 7,2 4,3 6,9 8,6 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,1 2,2 3 0,75 1,1 1,5 0,75 3 1,5 5,5 1,5 1,1 7,5 3 1,5 4800 6660 8500 5640 7200 9500 7100 13500 9500 19000 12000 8940 25500 17000 12440 81 85 88 73 76 81 71 83 73 84 76 68 87 77 70 55 67 82 71 90 74 69 97 89 155 113 102 256 205 180 R.R.P. € 1.051,70 1.181,90 1.443,40 1.368,80 1.404,80 1.880,20 1.596,30 2.057,60 2.086,50 2.806,80 2.604,80 2.613,10 3.028,60 3.038,70 2.886,10 CENTRIFUGAL MEDIUM PRESSURE FANS MBRC/FA Backward impeller, cubic casing MANUFACTURING FEATURES • Reinforced rolling steel sheet housings completely welded (internally and externally) with epoxy powder finishing coat. • Reinforced high efficiency backward curved impeller. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Hot air exhaust in ovens or facilities with high temperatures. • Clean and slightly dusty air transport. • Maximum working temperature: carried air up to 250ºC; environment: single phase 50ºC, three phase 60ºC. UNDER REQUEST • Drain plug and inspection door. • 60Hz fans and special voltages. • Hot air transport. • 2 speed motors. APPLICATIONS Designed for inline installation, they are suitable for: • Smoke emergency exhaust with motor outside the hazardous area. ACCESSORIES RFS INT PE AC EI BA-400 SIL-C SIL-R SINGLE PHASE RANGE Code Model R.P.M. max. Max. Curr. (A) Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 243400173 243450173 243510173 243500173 MBRC/FA 40/12 M4 0,75kW MBRC/FA 45/14 M4 1,1kW MBRC/FA 50/16 M4 1,5kW MBRC/FA 50/16 M6 0,75kW 1400 1400 1400 910 5,45 7,45 9,83 4,97 0,75 1,1 1,5 0,75 5640 7000 9500 7100 72 73 76 70 71 90 74 69 R.R.P. € 1.610,30 1.815,30 2.006,70 2.005,60 THREE PHASE RANGE Code Model R.P.M. max. 243410186 243400186 243450186 243510186 243500186 243570186 243560186 243650186 243640186 243730186 243720186 MBRC/FA 40/12 T2 3kW MBRC/FA 40/12 T4 0,75kW MBRC/FA 45/14 T4 1,1kW MBRC/FA 50/16 T4 1,5kW MBRC/FA 50/16 T6 0,75kW MBRC/FA 56/18 T4 3kW MBRC/FA 56/18 T6 1,5kW MBRC/FA 63/20 T4 5,5kW MBRC/FA 63/20 T6 1,5kW MBRC/FA 71/22 T4 7,5kW MBRC/FA 71/22 T6 3kW 2870 1400 1400 1400 910 1430 940 1440 940 1440 960 Max. Curr. (A) 230 400 690 11,1 3,48 4,74 6,31 4 11,7 6,9 6,9 12,4 6,4 2,01 2,75 3,65 2,3 6,8 4 12 4 15 7,2 6,9 8,6 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 3 0,75 1,1 1,5 0,75 3 1,5 5,5 1,5 7,5 3 8500 5640 7000 9500 7100 13500 9500 19000 12000 25500 17000 85 72 73 76 70 80 70 83 72 85 77 82 71 90 74 69 97 89 155 113 256 205 R.R.P. € 1.765,80 1.590,30 1.802,50 2.052,30 1.968,60 2.422,50 2.237,10 3.080,60 2.728,80 3.562,10 3.213,70 91 CENTRIFUGAL MEDIUM PRESSURE FANS MBRL Backward impeller MANUFACTURING FEATURES • Rolling steel sheet housing. • Fully welded or joined housing. • High efficiency single inlet backward curved impeller, manufactured in rolled steel sheet and epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors, 230/400V 50Hz for three phase, motors up to 4kW and 400/690V 50Hz for higher powers. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. ACCESSORIES 92 RFS INT PE AC EI • Clean and slightly dusty air transport. • Exhaust after filters, separators and cyclones. • Pneumatic transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. • Fans for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. • Special motors for frequency regulation (recommended for motor sizes IEC280 and larger). BA-400 SIL-C SIL-R CENTRIFUGAL MEDIUM PRESSURE FANS THREE PHASE RANGE Model R.P.M. max. MBRL 250 T2 0,55kW MBRL 280 T2 1,1kW MBRL 311 T2 2,2kW MBRL 351 T2 3kW MBRL 401 T2 4kW MBRL 402 T2 5,5kW MBRL 451 T2 7,5kW MBRL 452 T2 11kW MBRL 501 T2 15kW MBRL 502 T2 18,5kW MBRL 312 T4 0,18kW MBRL 352 T4 0,37kW MBRL 403 T4 0,55kW MBRL 453 T4 0,75kW MBRL 454 T4 1,1kW MBRL 503 T4 1,5kW MBRL 504 T4 2,2kW MBRL 561 T4 3kW MBRL 562 T4 4kW MBRL 631 T4 5,5kW MBRL 632 T4 7,5kW MBRL 711 T4 11kW MBRL 712 T4 15kW MBRL 801 T4 18,5kW MBRL 802 T4 22kW MBRL 901 T4 37kW MBRL 902 T4 45kW MBRL 1001 T4 55kW MBRL 802 T4 75kW MBRL 505 T6 0,37kW MBRL 506 T6 0,55kW MBRL 563 T6 0,75kW MBRL 564 T6 1,1kW MBRL 633 T6 1,5kW MBRL 634 T6 2,2kW MBRL 713 T6 3kW MBRL 714 T6 4kW MBRL 803 T6 5,5kW MBRL 804 T6 7,5kW MBRL 903 T6 11kW MBRL 904 T6 15kW MBRL 1003 T6 18,5kW MBRL 1004 T6 22kW MBRL 1121 T6 30kW MBRL 1122 T6 37kW MBRL 1251 T6 55kW MBRL 1252 T6 75kW 2800 2800 2800 2870 2890 2900 2900 2930 2930 2935 1400 1400 1400 1400 1400 1400 1430 1430 1440 1440 1440 1460 1460 1465 1470 1475 1475 1480 1480 900 900 910 910 940 940 960 960 960 965 970 970 975 975 980 980 980 985 Max. Curr. (A) 230 400 690 2,33 4,42 8,61 11,1 14,2 1,12 1,94 2,69 3,48 4,74 6,31 8,06 11,7 15,2 2,13 2,85 4 5,5 6,9 9,7 12,4 16,3 - 1,35 2,55 4,98 6,4 8,2 11 15 19,8 26,6 32 0,65 1,12 1,56 2,01 2,75 3,65 5 6,8 8,8 12 15 20,9 27,9 33 38,5 66,7 78,6 96,2 130 1,23 1,65 2,3 3,2 4 5,6 7,2 9,4 12,42 16,1 22,4 29,4 34,8 41,4 55,4 67,4 97 133,5 6,3 8,6 11,39 15,3 18,4 6,9 8,6 12,02 16,04 18,98 22,14 38,35 45,2 55,32 74,75 7,17 9,26 12,88 16,91 20,01 23,81 31,86 38,76 55,78 76,76 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,55 1,1 2,2 3 4 5,5 7,5 11 15 18,5 0,18 0,37 0,55 0,75 1,1 1,5 2,2 3 4 5,5 7,5 11 15 18,5 22 37 45 55 75 0,37 0,55 0,75 1,1 1,5 2,2 3 4 5,5 7,5 11 15 18,5 22 30 37 55 75 2700 3850 5400 7650 9500 12000 13500 17000 19000 24200 2700 3850 5400 6850 7650 9500 10800 13500 17000 19000 24200 27000 34200 38200 47500 54000 68500 76500 95400 6150 6850 8500 9000 12000 15300 17000 21600 24200 30600 34200 42500 47500 61000 68500 85000 95400 120600 70 72 76 79 82 84 86 88 89 92 57 60 64 65 67 69 71 72 74 75 78 79 82 83 85 86 88 90 93 57 59 60 62 66 68 69 72 73 75 76 78 80 82 83 85 86 88 33 43 52 80 95 108 124 160 187 196 42 65 75 89 94 123 129 141 146 190 204 315 326 402 418 630 650 832 941 115 116 131 133 173 179 276 286 330 368 500 499 697 716 1071 1212 1475 1596 R.R.P. € 825,70 1.001,70 1.237,30 1.469,20 1.720,30 1.909,40 2.167,10 2.483,40 2.809,80 2.961,50 1.105,50 1.286,90 1.506,30 1.723,70 1.751,60 2.055,10 2.117,10 2.536,90 2.617,50 3.259,00 3.348,40 4.254,30 4.354,40 5.412,40 5.560,70 8.177,10 8.508,20 10.135,90 11.208,40 1.992,40 2.003,90 2.428,40 2.450,00 3.001,60 3.090,90 3.822,20 3.896,60 4.765,00 5.053,80 6.796,20 7.240,80 8.584,40 8.813,90 11.412,10 12.078,70 15.792,60 19.774,90 93 CENTRIFUGAL MEDIUM PRESSURE FANS MBRLP Centrifugal medium pressure fan for paint booths MANUFACTURING FEATURES • Rolling steel sheet housing. • Fully welded or joined housing. • Flanged inlet to allow direct join in the paint shop outlet. • Inspection door included. • Cabin fans supplied, if requested, with sparkproof inlet. • High efficiency single inlet and backward curved impeller manufactured in rolled steel sheet with epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean and slightly dusty air transport. • Exhaust after filters in paint booths. • Exhaust after filters, separators and cyclones. • Pneumatic transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motor. • Flameproof or explosionproof fans with ATEX certified motors. • Hot-dipped galvanised or stainless steel fans. APPLICATIONS Designed to be fixed at the inlet double flange, with motor in vertical position. ACCESSORIES RFS INT PE RA CP AC EI BA-400 SIL-C SIL-R THREE PHASE RANGE Model MBRLP 454 T4 1,1kW MBRLP 503 T4 1,5kW MBRLP 561 T4 3kW MBRLP 562 T4 4kW MBRLP 631 T4 5,5kW MBRLP 632 T4 7,5kW MBRLP 633 T6 1,5kW MBRLP 634 T6 2,2kW MBRLP 713 T6 3kW MBRLP 714 T6 4kW 94 R.P.M. max. 1400 1400 1430 1440 1440 1440 940 940 960 960 Max. Curr. (A) 230 400 690 4,74 6,31 11,7 15,2 6,9 9,7 12,4 16,3 2,75 3,65 6,8 8,8 12 15 4 5,6 7,2 9,4 6,9 8,6 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,1 1,5 3 4 5,5 7,5 1,5 2,2 3 4 7650 9500 13500 17000 19000 24200 12000 15300 17000 21600 69 71 74 76 77 80 68 70 71 74 54 75 94 98 104 112 92 95 107 113 R.R.P. € 1.278,40 1.383,50 2.030,80 2.206,30 2.913,20 2.986,30 2.649,30 2.710,80 3.017,40 3.172,30 CENTRIFUGAL MEDIUM PRESSURE FANS MBRM Backward impeller, dusty air MANUFACTURING FEATURES • Rolling steel sheet housing. • Fully welded or joined housing. • High efficiency single inlet and backward curved impeller, manufactured in rolled steel sheet and epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and rated class F insulation. Manufactured with standard voltages: 230V 50Hz for single phase motors, 230/400V 50Hz for three phase, motors up to 4kW and 400/690V 50Hz for higher powers. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. ACCESSORIES RFS INT PE RA AC EI • Transport of dusty air and small loads of pellet materials. • Exhaust after filters, separators and cyclones. • Pneumatic transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. • Fans for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. • Special motors for frequency regulation (recommended for motor sizes IEC280 and larger). BA-400 SIL-C SIL-R THREE PHASE RANGE Model R.P.M. max. MBRM 220 T2 0,18kW MBRM 251 T2 0,25kW MBRM 252 T2 0,37kW MBRM 281 T2 0,55kW MBRM 282 T2 0,75kW MBRM 311 T2 1,1kW MBRM 312 T2 1,5kW MBRM 351 T2 1,5kW MBRM 352 T2 2,2kW MBRM 401 T2 3kW MBRM 402 T2 4kW MBRM 451 T2 5,5kW MBRM 452 T2 7,5kW MBRM 501 T2 11kW MBRM 502 T2 15kW MBRM 561 T2 18,5kW MBRM 562 T2 22kW MBRM 503 T4 1,1kW MBRM 504 T4 1,5kW MBRM 563 T4 2,2kW MBRM 564 T4 3kW MBRM 631 T4 4kW MBRM 632 T4 5,5kW MBRM 711 T4 7,5kW MBRM 712 T4 11kW MBRM 801 T4 15kW MBRM 802 T4 18,5kW MBRM 901 T4 30kW MBRM 902 T4 37kW MBRM 1001 T4 45kW MBRM 1002 T4 55kW MBRM 1121 T4 75kW MBRM 1122 T4 90kW MBRM 803 T6 4kW MBRM 804 T6 5,5kW MBRM 903 T6 7,5kW MBRM 904 T6 11kW MBRM 1003 T6 15kW MBRM 1004 T6 18,5kW MBRM 1123 T6 22kW MBRM 1124 T6 30kW MBRM 1251 T6 37kW MBRM 1252 T6 45kW 2800 2800 2800 2800 2800 2800 2800 2800 2800 2870 2890 2900 2900 2930 2930 2935 2940 1400 1400 1430 1430 1440 1440 1440 1460 1460 1465 1475 1475 1475 1480 1480 1485 960 960 965 970 970 975 975 980 980 980 Max. Curr. (A) 230 400 690 0,91 1,17 1,65 2,33 3,03 4,42 6,01 6,01 8,61 11,1 14,2 4,74 6,31 8,06 11,7 15,2 16,3 - 0,53 1,68 0,95 1,35 1,75 2,55 3,48 3,48 4,98 6,4 8,2 11 15 19,8 26,6 32 39 2,75 3,65 5 6,8 8,8 12 15 20,9 27,9 33 53,2 66,7 78,6 96,2 130 154,8 9,4 12,42 16,1 22,4 29,4 34,8 41,4 55,4 67,4 80,6 6,3 8,6 11,39 15,3 18,4 22,43 6,9 8,6 12,02 16,04 18,98 30,59 38,35 45,2 55,32 74,75 89,01 7,17 9,26 12,88 16,91 20,01 23,81 31,86 38,76 46,35 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,18 0,25 0,37 0,55 0,75 1,1 1,5 1,5 2,2 3 4 5,5 7,5 11 15 18,5 22 1,1 1,5 2,2 3 4 5,5 7,5 11 15 18,5 30 37 45 55 75 90 4 5,5 7,5 11 15 18,5 22 30 37 45 830 1330 1330 1900 1900 2700 2700 3850 3850 6150 6150 8500 8500 12000 12000 15300 15300 5400 5400 8500 8500 12000 12000 17000 17000 24200 24200 34200 34200 47500 42500 68500 68500 15300 15300 21600 21600 30600 30600 42500 42500 61000 61000 64 65 67 69 70 72 73 76 78 80 81 84 85 89 89 91 92 68 69 71 72 75 78 79 81 83 84 86 87 90 91 93 94 73 74 76 77 79 80 82 83 86 87 18 24 26 30 32 41 44 66 69 107 110 150 158 235 247 286 316 132 135 140 144 178 191 285 308 400 430 580 620 760 830 1220 1257 330 340 465 495 652 679 995 1043 1330 1405 R.R.P. € 491,50 546,40 552,90 655,60 697,30 768,20 796,10 962,30 984,00 1.322,70 1.387,90 1.830,30 1.886,10 2.420,10 2.461,50 3.325,60 3.639,40 1.688,30 1.706,90 2.481,20 2.509,20 3.124,10 3.294,60 4.179,60 4.503,70 5.201,30 5.459,90 7.353,70 7.828,80 8.995,00 9.601,70 12.728,10 13.170,90 4.743,50 4.812,50 6.348,00 6.448,00 7.727,60 8.050,10 10.333,70 10.968,80 13.764,70 14.723,10 95 CENTRIFUGAL MEDIUM PRESSURE FANS MBRU Backward impeller, dusty air, large pressures MANUFACTURING FEATURES • Rolling steel sheet housing. • Fully welded or joined housing. • High efficiency single inlet and backward curved impeller manufactured in rolling steel sheet with epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and rated class F insulation. Manufactured with standard voltages: 230V 50Hz for single phase motors, 230/400V 50Hz for three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. • Fans for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. • Special motors for frequency regulation (recommended for motor sizes IEC280 and larger). APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Transport of dusty air and small loads of pellet materials. • Exhaust after filters, separators and cyclones. • Pneumatic transport. ACCESSORIES RFS INT PE RA AC EI BA-400 SIL-C SIL-R THREE PHASE RANGE Model MBRU 250 T2 0,37kW MBRU 280 T2 0,55kW MBRU 310 T2 1,1kW MBRU 350 T2 2,2kW MBRU 400 T2 4kW MBRU 450 T2 7,5kW MBRU 501 T2 11kW MBRU 561 T2 15kW MBRU 562 T2 18,5kW MBRU 631 T2 30kW MBRU 632 T2 37kW MBRU 502 T4 1,1kW MBRU 563 T4 2,2kW MBRU 633 T4 4kW MBRU 711 T4 5,5kW MBRU 712 T4 7,5kW MBRU 801 T4 11kW MBRU 802 T4 15kW MBRU 901 T4 18,5kW MBRU 902 T4 30kW MBRU 1001 T4 37kW MBRU 1002 T4 45kW MBRU 1121 T4 55kW MBRU 1122 T4 75kW MBRU 1251 T4 110kW MBRU 1252 T4 132kW MBRU 803 T6 4kW MBRU 903 T6 7,5kW MBRU 1003 T6 11kW MBRU 1004 T6 15kW MBRU 1123 T6 18,5kW MBRU 1124 T6 22kW MBRU 1253 T6 30kW MBRU 1254 T6 37kW 96 R.P.M. max. 2800 2800 2800 2800 2890 2900 2930 2930 2935 2950 2955 1400 1430 1440 1440 1440 1460 1460 1465 1475 1475 1475 1480 1480 1485 1485 960 965 970 970 975 975 980 980 Max. Curr. (A) 230 400 690 1,65 2,33 4,42 8,61 14,2 4,74 8,06 15,2 16,3 - 0,95 1,35 2,55 4,98 8,2 15 19,8 26,6 32 52,6 64,3 2,75 5 8,8 12 15 20,9 27,9 33 53,2 66,7 78,6 96,2 130 188,6 225,1 9,4 16,1 22,4 29,4 34,8 41,4 55,4 67,4 8,6 11,39 15,3 18,4 30,25 36,97 6,9 8,6 12,02 16,04 18,98 30,59 38,35 45,2 55,32 74,75 108,45 129,43 9,26 12,88 16,91 20,01 23,81 31,86 38,76 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,37 0,55 1,1 2,2 4 7,5 11 15 18,5 30 37 1,1 2,2 4 5,5 7,5 11 15 18,5 30 37 45 55 75 110 132 4 7,5 11 15 18,5 22 30 37 1330 1900 2700 3850 5400 7650 10800 13500 15300 19000 21600 5400 7650 10800 13500 15300 19000 21600 27000 30600 38200 42500 54000 61800 76500 85000 15300 21600 27000 30600 38200 42500 54000 61800 61 64 68 71 75 78 82 84 85 88 89 63 67 71 73 74 77 78 80 81 84 85 87 88 91 92 67 70 74 75 77 78 80 81 25 30 40 67 105 150 230 282 292 380 390 128 138 175 270 281 327 397 416 671 749 759 1140 1212 1470 1530 337 486 612 642 967 987 1220 1316 R.R.P. € 608,30 718,90 835,40 1.075,00 1.506,60 2.040,40 2.602,20 3.439,10 3.590,80 4.971,00 5.180,60 1.870,30 2.746,40 3.452,60 4.517,60 4.607,00 5.762,20 5.862,20 7.569,40 8.216,50 9.657,30 9.988,40 12.981,50 14.054,00 19.640,80 20.478,90 5.404,50 7.210,70 8.276,40 8.721,00 11.429,90 11.659,50 14.760,30 15.426,90 CENTRIFUGAL MEDIUM PRESSURE FANS MBGR Backward impeller, dusty air, large pressures MANUFACTURING FEATURES • Rolling steel sheet housing. • Fully welded or joined housing. • High efficiency single inlet and backward curved impeller, manufactured in rolled steel sheet and epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and rated class F insulation. Manufactured with standard voltages: 230V 50Hz for single phase motors, 230/400V 50Hz for three phase, motors up to 4kW and 400/690V 50Hz for higher powers. • Exhaust after filters, separators and cyclones. • Pneumatic transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. • Fans for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. • Special motors for frequency regulation (recommended for motor sizes IEC280 and larger). APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Transport of dusty air and small loads of pellet materials. ACCESSORIES RFS INT PE RA AC EI BA-400 SIL-C Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 2,2 3 4 5,5 7,5 11 11 15 22 30 37 45 75 90 132 160 1,5 2,2 3 4 4 5,5 7,5 11 15 22 30 37 45 55 75 110 4 5,5 7,5 11 15 18,5 22 30 3050 4750 4250 6850 6150 9500 8500 13500 12000 19000 17000 27000 24200 38200 34200 54000 4250 6850 6150 9500 8500 13500 12000 19000 17000 27000 24200 38200 34200 54000 47500 76500 10800 17000 15300 24200 21600 34200 30600 47500 77 78 80 83 84 86 89 89 89 90 93 94 94 96 98 98 67 69 71 72 74 75 77 80 80 81 85 86 87 89 91 92 68 70 72 73 75 75 78 78 73 81 99 112 145 203 227 240 311 364 440 481 603 694 938 964 137 144 147 155 246 258 331 389 478 534 671 713 985 1056 1356 1392 388 399 556 587 825 906 1111 1182 SIL-R THREE PHASE RANGE Model R.P.M. max. 230 MBGR 401 T2 2,2kW MBGR 402 T2 3kW MBGR 451 T2 4kW MBGR 452 T2 5,5kW MBGR 501 T2 7,5kW MBGR 502 T2 11kW MBGR 561 T2 11kW MBGR 562 T2 15kW MBGR 631 T2 22kW MBGR 632 T2 30kW MBGR 711 T2 37kW MBGR 712 T2 45kW MBGR 801 T2 75kW MBGR 802 T2 90kW MBGR 901 T2 132kW MBGR 902 T2 160kW MBGR 563 T4 1,5kW MBGR 564 T4 2,2kW MBGR 633 T4 3kW MBGR 634 T4 4kW MBGR 713 T4 4kW MBGR 714 T4 5,5kW MBGR 803 T4 7,5kW MBGR 804 T4 11kW MBGR 903 T4 15kW MBGR 904 T4 22kW MBGR 1001 T4 30kW MBGR 1002 T4 37kW MBGR 1121 T4 45kW MBGR 1122 T4 55kW MBGR 1251 T4 75kW MBGR 1252 T4 110kW MBGR 905 T6 4kW MBGR 906 T6 5,5kW MBGR 1003 T6 7,5kW MBGR 1004 T6 11kW MBGR 1123 T6 15kW MBGR 1124 T6 18,5kW MBGR 1253 T6 22kW MBGR 1254 T6 30kW 2800 2870 2890 2900 2900 2930 2930 2930 2940 2950 2955 2960 2965 2970 2980 2980 1400 1430 1430 1440 1440 1440 1440 1460 1460 1470 1475 1475 1475 1480 1480 1485 960 960 965 970 970 975 975 980 8,61 11,1 14,2 6,31 8,06 11,7 15,2 15,2 16,3 - Max. Curr. (A) 400 690 4,98 6,4 8,2 11 15 19,8 19,8 26,6 39 52,6 64,3 77,1 126,6 151,7 219,9 263,1 3,65 5 6,8 8,8 8,8 12 15 20,9 27,9 38,5 53,2 66,7 78,6 96,2 130 188,6 9,4 12,42 16,1 22,4 29,4 34,8 41,4 55,4 6,3 8,6 11,39 11,39 15,3 22,43 30,25 36,97 44,33 72,8 87,23 126,44 151,28 6,9 8,6 12,02 16,04 22,14 30,59 38,35 45,2 55,32 74,75 108,45 7,17 9,26 12,88 16,91 20,01 23,81 31,86 R.R.P. € 1.367,90 1.445,40 1.748,00 1.937,20 2.238,30 2.554,70 3.132,50 3.173,90 4.541,80 5.010,60 5.952,30 6.721,40 8.605,90 9.624,90 15.127,60 15.827,40 2.419,30 2.481,20 3.411,50 3.492,20 4.224,30 4.394,90 5.291,70 5.615,80 6.732,90 7.139,80 8.303,60 8.778,70 11.381,50 11.988,10 16.404,80 19.526,00 6.275,20 6.344,20 7.297,80 7.397,80 10.114,10 10.436,60 14.010,40 14.645,50 97 CENTRIFUGAL MEDIUM PRESSURE FANS MBRH Backward impeller with no casing, air recirculation in ovens MANUFACTURING FEATURES • Fan including high efficiency single inlet and backward curved impeller, insulated wall, wall support, cooling wheel, and motor. • Insulated thickness and wall support fully welded and adapted to the customer needs. • Special coat finishing for high temperature applications. • Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors, 230/400V 50Hz for three phase, motors up to 4kW and 400/690V 50Hz for higher powers. • Default assembly position is LG270. ACCESSORIES RFS INT APPLICATIONS • Air recirculation in ovens. • Maximum working temperature: carried air 250ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Operation in high temperatures • Stainless steel fans. AC THREE PHASE RANGE Model R.P.M. max. MBRH 402 T4 0,75kW MBRH 452 T4 1,1kW MBRH 454 T4 1,5kW MBRH 504 T4 2,2kW MBRH 561 T4 3kW MBRH 562 T4 4kW MBRH 631 T4 5,5kW MBRH 711 T4 7,5kW MBRH 712 T4 11kW MBRH 713 T4 15kW MBRH 801 T4 18,5kW MBRH 802 T4 22kW MBRH 901 T4 30kW MBRH 902 T4 37kW MBRH 903 T4 45kW MBRH 403 T6 0,37kW MBRH 454 T6 0,75kW MBRH 503 T6 1,1kW MBRH 634 T6 2,2kW MBRH 714 T6 3kW MBRH 715 T6 4kW MBRH 803 T6 7,5kW MBRH 804 T6 11kW 1400 1400 1400 1430 1430 1440 1440 1440 1460 1460 1465 1470 1475 1475 1475 900 910 910 940 960 960 960 970 98 Max. Curr. (A) 230 400 690 3,48 4,74 6,31 8,06 11,7 15,2 2,13 4 5,5 9,7 12,4 16,3 - 2,01 2,75 3,65 5 6,8 8,8 12 15 20,9 27,9 33 38,5 53,2 66,7 78,6 1,23 2,3 3,2 5,6 7,2 9,4 12,42 22,4 6,9 8,6 12,02 16,04 18,98 22,14 30,59 38,35 45,2 7,17 12,88 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,75 1,1 1,5 2,2 3 4 5,5 7,5 11 15 18,5 22 30 37 40 0,37 0,75 1,1 2,2 3 4 7,5 11 5400 7650 8500 10800 13500 17000 19000 24200 27000 34200 38200 47500 50000 54000 68500 4500 5300 6200 13500 17000 21600 27000 30600 67 70 73 75 77 79 80 82 84 85 86 88 90 92 94 63 66 67 70 73 76 78 81 56,07 60,9 64,05 82,425 90,93 95,13 133,245 150,78 179,13 196,98 244,755 263,655 228,48 292,005 321,405 57,645 69,3 84,525 126,945 149,73 159,18 256,305 269,955 R.R.P. € 2.491,90 3.032,50 3.055,30 3.376,70 3.694,40 3.762,40 4.367,30 4.915,70 5.278,60 5.410,90 6.235,30 6.310,90 8.594,80 8.972,90 9.218,80 2.529,70 3.051,50 3.346,40 4.405,10 4.885,40 4.991,30 5.917,70 6.050,00 CENTRIFUGAL MEDIUM PRESSURE FANS MDI Forward impeller, stainless steel AISI 304 MANUFACTURING FEATURES • Welded stainless steel AISI 304 housing. • Stainless steel single inlet forward curved impeller. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof and explosionproof fans with ATEX certified motors. • Fans provided with cooling disk for high temperatures. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean air transport. • Corrosive air transport. • Maximum working temperature: carried air 130ºC; environment: single phase 50ºC, three phase 60ºC. ACCESSORIES REG RFS INT PE RAI SINGLE PHASE RANGE Code Model R.P.M. max. 300716100 300716200 300716300 300716400 300716500 300716600 300716700 300716800 300716900 300717000 300717100 300717200 300717300 MDI 10/5 M2 0,1kW MDI 12/6 M2 0,12kW MDI 13/6 M2 0,18kW MDI 13/6 M4 0,12kW MDI 13/8 M4 0,12kW MDI 13/8 M2 0,37kW MDI 16/8 M2 0,25kW MDI 16/8 M4 0,12kW MDI 18/8 M2 0,55kW MDI 18/8 M4 0,18kW MDI 20/10 M2 1,1kW MDI 20/10 M4 0,25kW MDI 25/13 M4 0,55kW 2760 2770 2800 1400 1400 2800 2800 1400 2800 1400 2800 1400 1400 Max. Curr. (A) 230 400 0,81 0,98 1,48 1,1 1,1 2,73 1,96 1,1 3,88 1,62 7,02 2,02 4,25 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,09 0,12 0,18 0,12 0,12 0,37 0,25 0,12 0,55 0,18 1,1 0,25 0,55 370 500 508 416 500 1275 900 835 1600 1266 3500 1600 3000 66 69 53 71 52 74 74 56 78 56 78 58 72 2,4 2,8 4,9 5,3 5,8 9,4 6,2 9 10,2 9,7 19 11 24 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,09 0,12 0,18 0,12 0,12 0,37 0,25 0,12 0,55 0,18 1,1 0,25 2,2 0,55 370 500 508 416 500 1275 900 835 1600 1266 3500 1600 3350 3000 66 69 71 53 52 74 74 56 78 56 78 58 85 72 2,4 2,8 5,3 4,9 5,8 9,4 6,2 9 10,2 9,7 19 11 32 24 R.R.P. € 503,20 558,30 566,10 566,10 603,80 591,20 735,90 710,70 767,40 729,70 943,50 830,20 1.660,60 THREE PHASE RANGE Code Model R.P.M. max. 300717600 300717700 300717800 300717900 300718000 300718100 300718200 300718300 300718400 300718500 300718600 300718700 300718800 300718900 MDI 10/5 T2 0,1kW MDI 12/6 T2 0,12kW MDI 13/6 T2 0,18kW MDI 13/6 T4 0,12kW MDI 13/8 T4 0,12kW MDI 13/8 T2 0,37kW MDI 16/8 T2 0,25kW MDI 16/8 T4 0,12kW MDI 18/8 T2 0,55kW MDI 18/8 T4 0,18kW MDI 20/10 T2 1,1kW MDI 20/10 T4 0,25kW MDI 25/13 T2 2,2kW MDI 25/13 T4 0,55kW 2800 2800 2800 1400 1400 2800 2800 1400 2800 1400 2800 1400 2800 1400 Max. Curr. (A) 230 400 0,57 0,67 0,91 0,84 0,84 1,65 1,17 0,84 2,33 1,12 4,42 1,44 8,61 2,69 0,33 0,38 0,53 0,48 0,48 0,95 1,68 0,48 1,35 0,65 2,55 0,83 4,98 1,56 R.R.P. € 459,20 498,90 506,40 506,40 537,80 531,50 676,20 651,00 691,90 660,40 830,20 754,80 1.673,20 1.534,70 99 CENTRIFUGAL MEDIUM PRESSURE FANS MBP Backward impeller, anticorrosive plastic material MANUFACTURING FEATURES • PE plastic housing. • Backward curved impeller in PP plastic. • Motor support made of rolled steel sheet with epoxy powder finishing coat. • Stainless steel nuts and bolts. • Standard asynchronous squirrel-cage motor, IP55, class F insulation. Standard voltages 230/400V 50Hz. • ATEX models equipped with II2G Eex-d motors. UNDER REQUEST • Single phase motors (up to 1,5kW). • 60Hz fans and special voltages fans. • 2 speed motors. • Stainless steel motor support. • Casing made of PP, PPS, PPel, PEs. Impeller made of PPs, PVDF. • Sparkproof fans with certified ATEX Eex-d. APPLICATIONS Designed for inline installation, they are suitable for: • Corrosive air transport. • Chemical and petrochemical industry. • Laboratories and gas cabinets. • Maximum working temperature: 50ºC. ACCESSORIES RFS INT THREE PHASE RANGE Code 243200170 243250170 243260170 243310170 243320170 243350170 243360170 243400170 243410170 243450170 243460170 100 Model MBP 20 T2 1/4 MBP 20 T4 1/6 MBP 25 T2 1/2 MBP 25 T4 1/6 MBP 31 T2 2 MBP 31 T4 1/3 MBP 31 T6 1/4 MBP 35 T2 3 MBP 35 T4 1/2 MBP 35 T6 1/4 MBP 40 T4 3/4 MBP 40 T6 1/3 MBP 45 T2 5,5 MBP 45 T4 1,5 MBP 45 T6 1/2 R.P.M. max. 2800 1400 2800 1400 2800 1400 880 2800 1400 880 1400 900 2890 1400 900 Max. Curr. (A) 230 400 0,9 0,74 2,1 0,74 5,3 1,4 1,2 6,9 2,1 1,2 2,45 1,4 14,9 4,65 2,1 0,6 0,43 1,2 0,43 3,4 0,81 0,7 4 1,2 0,7 1,42 0,81 8,61 2,69 1,2 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,18 0,12 0,37 0,12 1,5 0,25 0,18 2,2 0,37 0,18 0,55 0,25 4 1,1 0,37 1100 550 2500 1000 4500 2250 1500 6800 3400 2250 4750 2375 12000 6000 4250 63 47 68 53 76 61 50 76 60 54 68 56 82 64 56 9 9 13 10 26 19 19 32 23 23 33 30 52 41 37 R.R.P. € 638,00 638,00 870,70 823,90 1.366,50 1.127,30 1.123,30 1.531,80 1.263,40 1.259,20 1.727,30 1.563,30 3.089,50 1.945,30 1.702,80 CENTRIFUGAL MEDIUM PRESSURE FANS MBPC Forward impeller, anticorrosive plastic material MANUFACTURING FEATURES • PE plastic housing (antistatic PE-el for ATEX units). • Forward curved impeller in PP plastic. • Motor support made of rolled steel sheet with epoxy powder finishing coat. • Stainless steel nuts and bolts. • Standard asynchronous squirrel-cage motor, IP55, class F insulation. Standard voltages 230/400V 50Hz. UNDER REQUEST • Single phase motors (up to 1,5kW). • 60Hz fans and special voltages fans. • 2 speed motors. • Sparkproof fans with certified ATEX Eex-d. • Stainless steel motor support. • Casing made of PP, PPS, PPel, PEs. • Impeller made of PPs, PVDF. APPLICATIONS Designed for inline installation, they are suitable for: • Corrosive air transport. • Chemical and petrochemical industry. • Laboratories and gas cabinets. • Maximum working temperature: 50ºC. ACCESSORIES RFS INT PE THREE PHASE RANGE Code Model R.P.M. max. 300725400 300725500 300725600 300725700 300725800 300725900 300726000 300726100 300726200 300726300 300726400 300726500 300726600 300726700 300726800 300728800 300726900 300727000 300727100 300727200 300727300 300727400 MBPC 20 T2 0,25kW MBPC 20 T4 0,12kW MBPC 25 T2 0,75kW MBPC 25 T4 0,18kW MBPC 28 T2 1,1kW MBPC 28 T4 0,18kW MBPC 31 T2 1,5kW MBPC 31 T4 0,25kW MBPC 31 T6 0,12kW MBPC 35 T2 2,2kW MBPC 35 T4 0,37kW MBPC 40 T2 5,5kW MBPC 40 T2 4kW MBPC 40 T4 0,75kW MBPC 40 T6 0,25kW MBPC 45 T2 9kW MBPC 45 T4 1,1kW MBPC 45 T6 0,37kW MBPC 50 T4 2,2kW MBPC 50 T6 0,75kW MBPC 56 T4 5,5kW MBPC 56 T6 2,2kW 2800 1400 2800 1400 2800 1400 2800 1400 850 2800 1400 2900 2890 1400 900 2800 1400 900 1430 910 1440 940 Max. Curr. (A) 230 400 690 1,17 0,84 3,03 0,84 4,42 1,12 6,01 1,44 1,08 8,61 1,94 14,2 3,48 1,51 4,74 2,13 8,06 4 9,7 1,68 0,48 1,75 0,48 2,55 0,65 3,48 0,83 0,62 4,98 1,12 11 8,2 2,01 0,87 16,7 2,75 1,23 5 2,3 12 5,6 6,3 9,6 6,9 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,25 0,12 0,75 0,18 1,1 0,18 1,5 0,25 0,12 2,2 0,37 5,5 4 0,75 0,25 9 1,1 0,37 2,2 0,75 5,5 2,2 800 440 1500 780 2100 1100 2510 1400 920 2820 1970 5590 4080 2710 1930 7640 3650 2700 5440 4090 9150 8100 74 59 80 64 85 69 90 73 64 88 72 91 91 76 65 93 78 68 80 70 82 71 18 9 29 21 20 16 31 24 20 50 40 49 47 31 28 65 65 65 100 90 115 95 R.R.P. € 540,00 536,40 709,40 622,10 863,30 760,00 1.043,80 891,40 906,70 1.554,70 1.516,90 1.729,50 1.636,00 1.246,50 1.199,70 4.540,50 3.287,60 3.194,20 3.856,40 3.794,00 5.180,80 4.869,20 101 CENTRIFUGAL MEDIUM PRESSURE FANS GROUP Free shaft without motor or belt driven motor in different configurations MANUFACTURING FEATURES • Rolling steel sheet housing, fully welded and protected against corrosion with epoxy powder finishing coat. • Galvanised sheet (MZCA) or rolling steel sheet impeller (rest of ranges) protected against corrosion with epoxy powder finishing coat. • Supplied with free shaft, i.e. without motor, pulleys nor belts. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean air and pneumatic transport. • Clean air or slightly dusty air transport (MZRL). • Transport of dusty air or with low load of granulated materials (MZRM y MZRU). • Solid material transport and textile fibers (MZZM P/R). Size 220 250 280 310 350 400 450 500 560 630 710 800 900 1000 1120 Size 220 250 280 310 350 400 450 500 560 630 710 800 900 1000 Size 220 250 280 310 350 400 450 500 560 630 710 800 900 1000 1120 102 MZRM 1.004,90 € 1.160,10 € 1.276,50 € 1.501,60 € 1.769,30 € 1.940,00 € 2.172,80 € 2.685,00 € 3.383,40 € 4.109,00 € 5.203,20 € 5.827,90 € 7.333,30 € 8.629,30 € 11.500,50 € MZRM 1.327,00 € 1.482,20 € 1.606,30 € 1.846,90 € 2.118,50 € 2.351,30 € 2.584,10 € 3.305,80 € 4.062,40 € 4.896,60 € 5.986,90 € 6.759,10 € 8.264,60 € 9.603,20 € MZRM 1.544,30 € 1.699,50 € 1.839,20 € 2.157,30 € 2.471,60 € 2.902,30 € 3.135,10 € 3.798,60 € 4.803,50 € 5.630,00 € 7.096,60 € 7.822,20 € 9.669,10 € 11.190,10 € 14.383,40 € MZRU 1.295,90 € 1.420,10 € 1.668,40 € 1.971,10 € 2.161,20 € 2.417,30 € 2.987,70 € 3.771,40 € 4.586,20 € 5.812,30 € 6.731,90 € 8.481,80 € 10.002,80 € 13.335,80 € MZRU 1.618,00 € 1.749,90 € 2.013,80 € 2.669,50 € 2.572,50 € 2.828,60 € 3.608,50 € 5.187,70 € 5.366,10 € 6.592,20 € 7.659,30 € 9.413,10 € 10.976,70 € MZRU 1.839,20 € 1.982,70 € 2.324,20 € 2.316,40 € 3.123,50 € 3.383,40 € 4.101,20 € 4.446,60 € 6.099,50 € 7.698,10 € 8.730,20 € 10.817,60 € 12.567,50 € 16.214,80 € MZRL 1.218,30 € 1.311,50 € 1.521,00 € 1.815,90 € 1.994,40 € 2.238,80 € 2.770,40 € 3.558,00 € 4.252,60 € 5.210,90 € 6.095,60 € 7.387,70 € 9.153,10 € 11.927,30 € MZRL 1.536,50 € 1.645,10 € 1.866,30 € 2.165,10 € 2.405,60 € 2.650,10 € 3.391,20 € 4.233,20 € 5.032,50 € 5.994,70 € 7.030,70 € 8.322,80 € 10.123,10 € MZRL 1.757,70 € 1.870,20 € 2.176,70 € 2.514,30 € 2.956,60 € 3.204,90 € 3.884,00 € 4.978,10 € 5.765,80 € 7.104,40 € 8.097,70 € 9.727,30 € 11.706,20 € 14.810,20 € MZGR 2.021,50 € 2.308,60 € 2.875,10 € 3.624,00 € 4.415,50 € 5.540,70 € 6.243,00 € 7.919,20 € 9.261,70 € 12.311,50 € MZGR 2.432,80 € 2.719,90 € 3.495,90 € 4.303,00 € 5.199,30 € 6.324,50 € 7.178,10 € 8.850,40 € 10.231,70 € MZGR 2.983,80 € 3.274,80 € 3.984,80 € 5.044,10 € 5.932,60 € 7.434,20 € 8.245,10 € 10.251,10 € 11.814,80 € 15.190,50 € MZCA 1.090,30 € 1.156,30 € 1.342,50 € 1.524,90 € 1.707,20 € 1.940,00 € 2.234,90 € 2.731,60 € 3.709,30 € 4.318,50 € 5.276,90 € 6.243,00 € 7.884,30 € 9.312,20 € - MZCA 1.412,30 € 1.478,30 € 1.676,20 € 1.874,10 € 2.060,30 € 2.351,30 € 2.646,20 € 3.352,40 € 4.388,40 € 5.106,20 € 6.060,70 € 7.178,10 € 8.819,40 € 10.282,20 € MZCA 1.629,60 € 1.695,60 € 1.905,10 € 2.180,60 € 2.409,50 € 2.902,30 € 3.197,20 € 3.845,10 € 5.129,50 € 5.839,50 € 7.166,50 € 8.245,10 € 10.728,40 € 12.455,00 € - UNDER REQUEST • Fully equipped fans including motor, pulleys, belts, belts guard and shaft guard. Assembled on a base plate. • Flameproof and explosionproof fans with ATEX certified motors. • Fans for air working temperatures up to 250ºC, 300ºC or 450ºC. • Hot-dipped galvanised or stainless steel fans. NOTE Fans are supplied as free shaft. For the price of whole assembled set (motor and transmission execution 9 or 12), please add to the fan cost: motor and corresponding transmission set size prices. Prices in accessories section (p.124). MZZM 1.004,90 € 1.152,40 € 1.272,70 € 1.466,70 € 1.742,20 € 1.924,50 € 2.110,80 € 2.634,60 € 3.348,50 € 4.023,60 € 5.094,50 € 5.684,30 € 7.333,30 € 8.466,30 € - MZZM 1.327,00 € 1.474,40 € 1.602,50 € 1.815,90 € 2.200,00 € 2.335,80 € 2.522,00 € 3.251,50 € 4.027,50 € 4.807,40 € 5.882,20 € 6.619,40 € 8.264,60 € 9.436,30 € MZZM 1.544,30 € 1.691,70 € 1.831,40 € 2.126,30 € 2.440,60 € 2.886,80 € 3.076,90 € 3.744,30 € 4.244,80 € 5.540,70 € 6.984,10 € 7.647,60 € 9.669,10 € 11.023,30 € - FAN EXECUTION 1 (FREE SHAFT) FAN EXECUTION 9 (FREE SHAFT WITH BACKPACK) FAN CONFIGURATION 12 (FREE SHAFT WITH BASEMENT) CENTRIFUGAL HIGH PRESSURE FANS AA Forward cast aluminium impeller MANUFACTURING FEATURES • Rolling steel sheet housing. • Fully welded housing. • AA 47-70: high efficiency single inlet and forward curved impeller manufactured in cast aluminium. • AA 45/5-60/7: high efficiency single inlet and backward curved impeller manufactured in cast aluminium. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and class F insulation. Standard voltages 230/400V 50Hz, motors up to 4kW and 400/690V 50Hz for higher powers. AA 47-70 • Exhaust after filters, separators and cyclones. • Pneumatic transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof ATEX certified motors. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean air transport. AA 45/5-60/7 ACCESSORIES RFS INT PE RA AC EI BA-400 SIL-C SIL-R AA 47-70 Code Model R.P.M. max. 255140160 255170160 255250160 255280160 255350161 255350160 255430160 255440160 255490160 255500160 255510160 AA 47 T2 0,55kW AA 47 T2 1,1kW AA 53 T2 1,1kW AA 53 T2 2,2kW AA 59 T2 1,5kW AA 59 T2 2,2kW AA 66 T2 2,2kW AA 66 T2 3kW AA 70 T2 4kW AA 70 T2 5,5kW AA 70 T2 7,5kW 2800 2800 2800 2800 2800 2800 2800 2870 2890 2900 2900 Max. Curr. (A) 230 400 690 2,33 4,42 4,42 8,61 6,01 8,61 8,61 11,1 14,2 - 1,35 2,55 2,55 4,98 3,48 4,98 4,98 6,4 8,2 11 15 6,3 8,6 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,55 1,1 1,1 2,2 1,5 2,2 2,2 3 4 5,5 7,5 450 790 600 1300 550 900 475 790 1000 1500 1700 70 73 72 73 73 74 75 78 80 80 82 41,5 49,5 55,5 67 69 70 82 89 103,5 118,5 125 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 2,2 3 4 5,5 7,5 11 2600 3600 3600 4800 3650 5600 86 90 91 91 95 98 62,5 69,5 79 92 108 141 R.R.P. € 1.166,00 1.258,10 1.331,60 1.392,10 1.429,20 1.532,60 1.741,50 1.864,40 2.073,90 2.124,30 2.159,00 AA 45/5-60/7 Code Model R.P.M. max. 255120106 255120120 255150106 255150120 255520106 255520120 AA 45/5 T2 2,2kW AA 45/5 T2 3kW AA 50/5 T2 4kW AA 50/5 T2 5,5kW AA 60/7 T2 7,5kW AA 60/7 T2 11kW 2800 2870 2890 2900 2900 2930 Max. Curr. (A) 230 400 690 8,61 11,1 14,2 - 4,98 6,4 8,2 11 15 19,8 6,3 8,6 11,39 R.R.P. € 1.357,80 1.521,20 2.017,70 2.340,90 2.794,50 3.051,60 103 CENTRIFUGAL HIGH PRESSURE FANS AAVA Backward impeller MANUFACTURING FEATURES • Rolling steel sheet housing. • High efficiency single inlet backward curved impeller, manufactured in rolling steel sheet with epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors, and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Exhaust after filters, separators and cyclones. • Pneumatic transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof ATEX certified motors. • Fans for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean air transport. ACCESSORIES RFS INT PE RA AC EI BA-400 SIL-C SIL-R THREE PHASE RANGE Model AAVA 310/P T2 0,25kW AAVA 350/P T2 0,37kW AAVA 400/P T2 0,55kW AAVA 450/P T2 0,75kW AAVA 500/P T2 1,1kW AAVA 560/P T2 1,5kW AAVA 631/P T2 1,5kW AAVA 632/P T2 2,2kW AAVA 711/P T2 3kW AAVA 712/P T2 4kW AAVA 801/P T2 4kW AAVA 802/P T2 5,5kW AAVA 902/P T2 11kW 104 R.P.M. max. 2800 2800 2800 2800 2800 2800 2800 2800 2870 2890 2890 2900 2930 Max. Curr. (A) 230 400 690 1,17 1,65 2,33 3,03 4,42 6,01 6,01 8,61 11,1 14,2 14,2 - 1,68 0,95 1,35 1,75 2,55 3,48 3,48 4,98 6,4 8,2 8,2 11 19,8 6,3 11,39 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,25 0,37 0,55 0,75 1,1 1,5 1,5 2,2 3 4 4 5,5 11 216 252 288 324 360 396 324 468 468 612 540 612 1080 65 67 69 71 73 75 76 77 79 80 82 84 88 22 24 36 39 42 59 63 66 94 100 111 125 210 R.R.P. € 890,70 984,30 1.083,00 1.215,80 1.298,50 1.393,70 1.476,80 1.498,50 1.777,90 1.843,00 2.064,60 2.253,80 3.286,90 CENTRIFUGAL HIGH PRESSURE FANS AAVC Backward impeller MANUFACTURING FEATURES • Rolling steel sheet housing. • Fully welded housing. • High efficiency single inlet backward curved impeller manufactured in rolling steel sheet and epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Clean air transport. • Exhaust after filters, separators and cyclones. • Pneumatic transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. • Fans for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. ACCESSORIES RFS INT PE RA AC EI BA-400 SIL-C SIL-R THREE PHASE RANGE Model R.P.M. max. AAVC/N 500 T2 1,1kW AAVC/N 560 T2 1,5kW AAVC/N 560 T2 2,2kW AAVC/NR 630 T2 2,2kW AAVC/NR 630 T2 3kW AAVC/N 630 T2 3kW AAVC/N 630 T2 4kW AAVC/NR 710 T2 4kW AAVC/NR 710 T2 5,5kW AAVC/N 710 T2 5,5kW AAVC/N 710 T2 7,5kW AAVC/NR 800 T2 7,5kW AAVC/N 800 T2 11kW AAVC/NR 900 T2 11kW AAVC/NR 900 T2 15kW AAVC/N 900 T2 15kW AAVC/N 900 T2 18,5kW AAVC/NR 1000 T2 22kW AAVC/N 1000 T2 22kW AAVC/N 1000 T2 30kW AAVC/NR 1120 T2 45kW AAVC/N 1120 T2 45kW AAVC/N 1120 T2 55kW 2800 2800 2800 2800 2870 2870 2890 2890 2900 2900 2900 2900 2930 2930 2930 2930 2935 2940 2940 2950 2960 2960 2965 Max. Curr. (A) 230 400 690 4,42 6,01 8,61 8,61 11,1 11,1 14,2 14,2 - 2,55 3,48 4,98 4,98 6,4 6,4 8,2 8,2 11 11 15 15 19,8 19,8 26,6 26,6 32 39 39 52,6 77,1 77,1 94,2 6,3 6,3 8,6 8,6 11,39 11,39 15,3 15,3 18,4 22,43 22,43 30,25 44,33 44,33 54,17 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,1 1,5 2,2 2,2 3 3 4 4 5,5 5,5 7,5 7,5 11 11 15 15 18,5 22 22 30 45 45 55 648 504 1044 756 1296 864 1476 1152 1872 1296 2376 1476 2376 1476 2628 2160 3024 2628 1872 3420 4716 3744 6120 75 79 79 81 82 83 83 87 87 87 88 88 90 91 91 92 92 93 94 94 95 98 98 63 95 98 125 130 130 134 162 179 185 188 219 256 357 369 369 380 467 467 522 730 730 795 R.R.P. € 1.939,60 2.398,90 2.420,60 2.713,50 2.791,00 2.791,00 2.856,20 3.366,70 3.555,80 3.555,80 3.611,60 4.403,20 4.719,50 5.621,90 5.663,30 5.663,30 5.815,00 7.957,30 7.957,30 8.426,10 12.135,60 12.135,60 12.735,90 105 CENTRIFUGAL HIGH PRESSURE FANS AAVP Backward impeller MANUFACTURING FEATURES • Rolling steel sheet housing. • Fully welded housing. • High efficiency single inlet backward curved impeller manufactured in rolling steel sheet and epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. ACCESSORIES RFS INT PE RA AC EI • Clean and slightly dusty air transport. • Exhaust after filters, separators and cyclones. • Pneumatic transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. • Fan for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. • Special motors for frequency regulation (recommended for motor sizes IEC280 and larger). BA-400 SIL-C SIL-R THREE PHASE RANGE Model R.P.M. max. AAVP/N 400 T2 1,1kW AAVP/N 451 T2 1,1kW AAVP/N 452 T2 1,5kW AAVP/NR 501 T2 1,1kW AAVP/NR 502 T2 1,5kW AAVP/N 501 T2 1,5kW AAVP/N 502 T2 2,2kW AAVP/NR 561 T2 1,5kW AAVP/NR 562 T2 2,2kW AAVP/NR 563 T2 3kW AAVP/N 561 T2 2,2kW AAVP/N 562 T2 3kW AAVP/N 563 T2 4kW AAVP/NR 631 T2 3kW AAVP/NR 632 T2 4kW AAVP/NR 633 T2 5,5kW AAVP/N 631 T2 4kW AAVP/N 632 T2 5,5kW AAVP/N 633 T2 7,5kW AAVP/NR 711 T2 7,5kW AAVP/NR 713 T2 11kW AAVP/N 712 T2 11kW AAVP/N 713 T2 15kW AAVP/NR 801 T2 11kW AAVP/NR 802 T2 15kW AAVP/NR 803 T2 18,5kW AAVP/N 801 T2 15kW AAVP/N 802 T2 18,5kW AAVP/N 803 T2 22kW AAVP/NR 901 T2 18,5kW AAVP/NR 902 T2 22kW AAVP/NR 903 T2 30kW AAVP/N 901 T2 22kW AAVP/N 902 T2 30kW AAVP/N 903 T2 37kW AAVP/NR 1001 T2 37kW AAVP/NR 1002 T2 45kW AAVP/NR 1003 T2 55kW AAVP/N 1001 T2 45kW AAVP/N 1002 T2 55kW AAVP/N 1003 T2 75kW AAVP/NR 1121 T2 55kW AAVP/NR 1122 T2 75kW AAVP/NR 1123 T2 90kW AAVP/N 1121 T2 75kW AAVP/N 1122 T2 90kW AAVP/N 1123 T2 110kW 2800 2800 2800 2800 2800 2800 2800 2800 2800 2870 2800 2870 2890 2870 2890 2900 2890 2900 2900 2900 2930 2930 2930 2930 2930 2935 2930 2935 2940 2935 2940 2950 2940 2950 2955 2955 2960 2965 2960 2965 2965 2965 2965 2970 2965 2970 2975 106 Max. Curr. (A) 230 400 690 4,42 4,42 6,01 4,42 6,01 6,01 8,61 6,01 8,61 11,1 8,61 11,1 14,2 11,1 14,2 14,2 - 2,55 2,55 3,48 2,55 3,48 3,48 4,98 3,48 4,98 6,4 4,98 6,4 8,2 6,4 8,2 11 8,2 11 15 15 19,8 19,8 26,6 19,8 26,6 32 26,6 32 39 32 39 52,6 39 52,6 64,3 64,3 77,1 94,2 77,1 94,2 126,6 94,2 126,6 151,7 126,6 151,7 185 6,3 6,3 8,6 8,6 11,39 11,39 15,3 11,39 15,3 18,4 15,3 18,4 22,43 18,4 22,43 30,25 22,43 30,25 36,97 36,97 44,33 54,17 44,33 54,17 72,8 54,17 72,8 87,23 72,8 87,23 106,38 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,1 1,1 1,5 1,1 1,5 1,5 2,2 1,5 2,2 3 2,2 3 4 3 4 5,5 4 5,5 7,5 7,5 11 11 15 11 15 18,5 15 18,5 22 18,5 22 30 22 30 37 37 45 55 45 55 75 55 75 90 75 90 110 792 900 1152 648 1008 792 380 720 1152 1620 900 1296 2160 1008 1620 2628 1152 1836 2988 2340 2988 3780 4716 2628 3780 5328 2988 4212 5328 3348 4212 6768 2988 4716 6768 5328 7560 9468 6048 7560 11988 6768 9468 13320 7560 9468 13320 72 73 74 75 77 77 77 79 79 80 80 81 81 82 82 82 83 87 87 88 89 89 89 90 90 90 90 90 92 91 93 93 94 94 94 95 95 95 95 95 95 97 97 97 99 99 99 48 57 63 62 65 65 67 94 96 102 98 107 111 128 136 147 136 150 155 189 220 196 230 261 267 278 272 283 305 400 422 537 428 543 554 630 674 746 681 753 852 860 999 992 967 959 1158 R.R.P. € 1.405,30 1.539,90 1.567,80 1.971,30 1.999,20 1.999,20 2.020,90 2.434,50 2.456,30 2.533,80 2.456,30 2.533,80 2.598,90 2.862,30 2.927,40 3.116,50 2.927,40 3.116,50 3.172,30 3.663,10 3.979,40 3.979,40 4.020,80 4.763,10 4.804,50 4.956,20 4.804,50 4.956,20 5.270,00 5.925,80 6.239,60 6.708,40 6.239,60 6.708,40 6.918,00 8.936,40 9.705,50 10.305,90 9.705,50 10.305,90 10.782,60 13.092,10 13.568,90 14.587,80 13.568,90 14.587,80 18.861,00 CENTRIFUGAL HIGH PRESSURE FANS AAVG/N Backward impeller MANUFACTURING FEATURES • Rolling steel sheet housing. • Fully welded housing. • High efficiency single inlet backward curved impeller, manufactured in rolling steel sheet and epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean and slightly dusty air transport. ACCESSORIES RFS INT PE RA AC EI • Exhaust after filters, separators and cyclones. • Pneumatic transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. • Fans for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. • Special motors for frequency regulation (recommended for motor sizes IEC280 and larger). BA-400 SIL-C SIL-R THREE PHASE RANGE Model R.P.M. max. AAVG/N 350 T2 1,1kW AAVG/N 400 T2 1,5kW AAVG/N 450 T2 2,2kW AAVG/NR 501 T2 3kW AAVG/NR 502 T2 4kW AAVG/N 501 T2 4kW AAVG/N 502 T2 5,5kW AAVG/NR 561 T2 5,5kW AAVG/NR 562 T2 7,5kW AAVG/N 561 T2 7,5kW AAVG/NR 632 T2 11kW AAVG/N 631 T2 11kW AAVG/N 632 T2 15kW AAVG/NR 711 T2 18,5kW AAVG/NR 712 T2 22kW AAVG/N 711 T2 22kW AAVG/N 712 T2 30kW AAVG/NR 801 T2 30kW AAVG/NR 802 T2 37kW AAVG/N 801 T2 37kW AAVG/N 802 T2 45kW AAVG/NR 901 T2 55kW AAVG/NR 902 T2 75kW AAVG/N 901 T2 75kW AAVG/N 902 T2 90kW AAVG/NR 1001 T2 90kW AAVG/NR 1002 T2 110kW AAVG/N 1001 T2 110kW AAVG/N 1002 T2 132kW 2800 2800 2800 2870 2890 2890 2900 2900 2900 2900 2930 2930 2930 2935 2940 2940 2950 2950 2955 2955 2960 2965 2965 2965 2970 2970 2975 2975 2980 Max. Curr. (A) 230 400 690 4,42 6,01 8,61 11,1 14,2 14,2 - 2,55 3,48 4,98 6,4 8,2 8,2 11 11 15 15 19,8 19,8 26,6 32 39 39 52,6 52,6 64,3 64,3 77,1 94,2 126,6 126,6 151,7 151,7 185 185 219,9 6,3 6,3 8,6 8,6 11,39 11,39 15,3 18,4 22,43 22,43 30,25 30,25 36,97 36,97 44,33 54,17 72,8 72,8 87,23 87,23 106,38 106,38 126,44 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,1 1,5 2,2 3 4 4 5,5 5,5 7,5 7,5 11 11 15 18,5 22 22 30 30 37 37 45 55 75 75 90 90 110 110 132 1044 1296 1836 2124 3024 2376 3384 3384 4680 3600 6084 4140 6804 6804 9504 6804 10800 8460 11880 8460 13428 11880 21600 15228 23760 15228 23760 17028 26640 78 79 80 81 81 82 86 87 87 87 89 89 89 91 93 93 94 95 95 96 96 96 97 97 97 98 98 99 99 33 53 65 87 93 93 107 127 133 135 193 196 198 246 368 272 388 424 435 440 484 701 802 808 840 920 1078 1085 1112 R.R.P. € 1.322,20 1.520,30 1.811,20 2.153,90 2.219,00 2.219,00 2.408,10 2.720,80 2.776,60 2.776,60 3.532,20 3.532,20 3.573,60 4.449,60 4.763,40 4.763,40 5.232,20 6.969,60 7.179,20 7.179,20 7.948,30 9.652,90 10.129,60 10.129,60 11.148,60 12.913,70 17.186,90 17.186,90 17.399,30 107 CENTRIFUGAL HIGH PRESSURE FANS AAVM Backward impeller MANUFACTURING FEATURES • Rolling steel sheet housing. • Fully welded housing. • High efficiency single inlet backward curved impeller, manufactured in rolling steel sheet and epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. ACCESSORIES RFS INT PE RA AC EI • Clean and slightly dusty air transport. • Exhaust after filters, separators and cyclones. • Pneumatic transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. • Fans for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. • Special motors for frequency regulation (recommended for motor sizes IEC280 and larger). BA-400 SIL-C SIL-R THREE PHASE RANGE Max. Curr. (A) 400 690 Model R.P.M. max. 230 AAVM/NR 350 T2 0,75kW AAVM/N 350 T2 1,1kW AAVM/NR 400 T2 1,5kW AAVM/N 400 T2 2,2kW AAVM/NR 450 T2 3kW AAVM/N 450 T2 4kW AAVM/NR 500 T2 4kW AAVM/N 500 T2 5,5kW AAVM/NR 560 T2 7,5kW AAVM/N 560 T2 11kW AAVM/NR 630 T2 15kW AAVM/N 630 T2 18,5kW AAVM/NR 711 T2 22kW AAVM/N 711 T2 30kW AAVM/NR 801 T2 37kW AAVM/N 801 T2 55kW AAVM/NR 901 T2 75kW AAVM/N 901 T2 90kW AAVM/NR 1001 T2 110kW AAVM/N 1001 T2 160kW 2800 2800 2800 2800 2870 2890 2890 2900 2900 2930 2930 2935 2940 2950 2955 2965 2965 2970 2975 2980 3,03 4,42 6,01 8,61 11,1 14,2 14,2 - 108 1,75 2,55 3,48 4,98 6,4 8,2 8,2 11 15 19,8 26,6 32 39 52,6 64,3 94,2 126,6 151,7 185 263,1 6,3 8,6 11,39 15,3 18,4 22,43 30,25 36,97 54,17 72,8 87,23 106,38 151,28 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,75 1,1 1,5 2,2 3 4 4 5,5 7,5 11 15 18,5 22 30 37 55 75 90 110 160 1296 1656 1872 2376 2664 3384 3384 4680 4680 6480 6480 9360 8280 11988 11988 18720 18720 23760 21240 33840 69 70 74 75 76 77 80 84 86 87 88 89 91 92 92 93 93 94 94 95 32 36 48 52 63 78 93 106 133 141 193 206 276 396 436 550 802 841 1085 1115 R.R.P. € 863,50 879,00 997,90 1.019,60 1.469,20 1.534,30 1.732,20 1.921,30 2.507,40 2.823,80 3.348,00 3.499,80 4.696,10 5.164,90 6.961,50 8.331,00 10.129,60 11.148,60 17.843,90 18.756,10 CENTRIFUGAL HIGH PRESSURE FANS AA P/R Straight blade impeller MANUFACTURING FEATURES • Rolling steel sheet housing. • Fully welded housing. • Straight blade impeller manufactured in rolled steel sheet and epoxy powder finishing coat. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof ATEX certified motors. • Hot-dipped galvanised or stainless steel fan. APPLICATIONS Designed for inline installation, they are suitable for: • Solid material transport (except for textile fibers). • Maximum working temperature: carried air 130ºC; environment: 60ºC. ACCESSORIES RFS INT PE AC EI BA-400 SIL-C SIL-R THREE PHASE RANGE Code Model R.P.M. max. 255120160 255120161 255150160 255150161 255520161 255520160 AA 45/5 T2 2,2kW P/R AA 45/5 T2 3kW P/R AA 50/5 T2 4kW P/R AA 50/5 T2 5,5kW P/R AA 60/7 T2 7,5kW P/R AA 60/7 T2 11kW P/R 2800 2870 2890 2900 2900 2930 Max. Curr. (A) 230 400 690 8,61 11,1 14,2 - 4,98 6,4 8,2 11 15 19,8 6,3 8,6 11,39 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 2,2 3 4 5,5 7,5 11 2900 3100 3100 4000 4500 5000 87 88 91 92 92 93 68 69 119 120 150 177 R.R.P. € 1.768,60 1.803,30 1.940,20 2.251,50 2.431,60 2.701,40 109 CENTRIFUGAL HIGH PRESSURE FANS AAZA P/R Straight blade impeller MANUFACTURING FEATURES • Rolling steel sheet housing. • Fully welded housing. • Straight blade impeller manufactured in rolled steel sheet and epoxy powder coat finishing. • Epoxy powder coat finishing. • Standard asynchronous squirrel-cage motor with IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. • Flameproof or explosionproof fans with ATEX certified motors. • Fans for air working temperatures up to 250ºC. • Hot-dipped galvanised or stainless steel fans. APPLICATIONS Designed for inline installation, they are suitable for: • Transport of solid material and textile fibers. • Maximum working temperature: carried air 130ºC; environment: 60ºC. ACCESSORIES RFS INT PE AC EI BA-400 SIL-C SIL-R THREE PHASE RANGE Model R.P.M. max. AAZA 400 T2 0,75kW P/R AAZA 400 T2 1,1kW P/R AAZA 450 T2 1,1kW P/R AAZA 450 T2 1,5kW P/R AAZA 500 T2 2,2kW P/R AAZA 500 T2 3kW P/R AAZA 560 T2 3kW P/R AAZA 560 T2 4kW P/R AAZA 630 T2 5,5kW P/R AAZA 630 T2 7,5kW P/R AAZA 710 T2 7,5kW P/R AAZA 710 T2 11kW P/R AAZA 800 T2 11kW P/R AAZA 800 T2 15kW P/R AAZA 800 T2 18,5kW P/R AAZA 800 T4 3kW P/R AAZA 800 T4 4kW P/R AAZA 900 T4 5,5kW P/R AAZA 900 T4 7,5kW P/R AAZA 1000 T4 11kW P/R 2800 2800 2800 2800 2800 2870 2870 2890 2900 2900 2900 2930 2930 2930 2935 1430 1440 1440 1440 1460 110 Max. Curr. (A) 230 400 690 3,03 4,42 4,42 6,01 8,61 11,1 11,1 14,2 11,7 15,2 - 1,75 2,55 2,55 3,48 4,98 6,4 6,4 8,2 11 15 15 19,8 19,8 26,6 32 6,8 8,8 12 15 20,9 6,3 8,6 8,6 11,39 11,39 15,3 18,4 6,9 8,6 12,02 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,75 1,1 1,1 1,5 2,2 3 3 4 5,5 7,5 7,5 11 11 15 18,5 3 4 5,5 7,5 11 360 792 468 792 1044 1656 900 1476 620 545 1152 2376 1872 2124 2664 2124 2124 3024 3024 4140 79 79 84 84 86 87 89 89 94 94 97 97 98 99 100 79 80 82 83 87 31 32 36 40 58 65 80 85 122 128 148 185 245 248 282 169 178 266 294 457 R.R.P. € 1.389,90 1.405,30 1.539,90 1.567,80 1.874,50 1.952,00 2.363,60 2.428,70 2.914,70 2.970,50 3.473,10 3.789,50 4.588,90 4.630,30 4.782,10 3.965,60 4.046,20 5.249,70 5.339,20 10.448,10 CENTRIFUGAL HIGH PRESSURE FANS GROUP Free shaft without motor or belt driven motor in different configurations MANUFACTURING FEATURES • Rolling steel sheet housing, fully welded and protected against corrosion with epoxy powder finishing coat. • High efficiency single inlet backward curved impeller manufactured in rolling steel sheet protected against corrosion with epoxy powder finishing coat. AAZZA P/R range with straight blade turbine in steel sheet protected with epoxy powder. • Supplied with free shaft, (i.e. without motor, pulleys nor belts). APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Pneumatic transport. • Clean air (AAZVA, AAZVC) or slightly dusty air transport (AAZVP, AAZVG, AAZVM). Size AAZZA 350 400 450 500 560 630 710 800 900 1000 1120 2.200,00 € 2.654,00 € 2.964,40 € 3.402,80 € 3.724,90 € 4.780,20 € 5.637,70 € 7.185,90 € 12.684,00 € - Size AAZZA 350 400 450 500 560 630 710 800 900 1000 Size 350 400 450 500 560 630 710 800 900 1000 1120 2.591,90 € 3.065,30 € 3.488,20 € 3.984,80 € 4.306,90 € 5.455,40 € 6.421,50 € 8.113,20 € 13.654,00 € AAZZA 3.061,40 € 3.515,30 € 4.178,80 € 4.737,60 € 5.203,20 € 6.472,00 € 7.445,90 € 9.234,60 € 14.841,30 € - AAZVG/N AAZVG/P 1.637,40 € 2.037,00 € 2.440,60 € 2.654,00 € 3.740,40 € 4.694,90 € 5.986,90 € 7.698,10 € 10.309,30 € 13.941,10 € 14.651,10 € AAZVM 3.084,70 € 3.550,30 € 3.868,40 € 4.923,80 € 5.781,30 € 6.786,20 € 7.523,50 € 13.591,90 € 2.110,80 € 2.607,40 € 2.894,50 € 3.173,90 € 4.019,80 € 4.927,70 € 6.060,70 € 7.938,60 € 10.309,30 € 12.788,70 € - 2.110,80 € 2.607,40 € 2.894,50 € 3.173,90 € 4.019,80 € 4.927,70 € 6.060,70 € 7.938,60 € 10.309,30 € - 2.207,80 € 2.347,40 € 3.123,50 € 3.596,80 € 3.946,00 € 4.978,10 € 5.824,00 € 7.306,20 € 9.824,30 € 12.831,40 € AAZVM AAZVC AAZVG/N AAZVG/P AAZVP 2.460,00 € 2.999,30 € 3.305,80 € 3.701,60 € 4.605,60 € 5.509,70 € 6.735,80 € 8.718,50 € 11.240,60 € 13.758,70 € 2.460,00 € 2.999,30 € 3.305,80 € 3.701,60 € 4.605,60 € 5.509,70 € 6.735,80 € 8.718,50 € 11.240,60 € - AAZVG/N AAZVG/P 2.929,50 € 3.468,80 € 3.755,90 € 4.392,20 € 5.350,60 € 6.406,00 € 7.752,40 € 9.746,70 € 12.361,90 € 14.946,00 € - 2.929,50 € 3.468,80 € 3.755,90 € 4.392,20 € 5.350,60 € 6.406,00 € 7.752,40 € 9.746,70 € 12.361,90 € - 1.982,70 € 2.428,90 € 2.848,00 € 3.177,80 € 4.326,30 € 5.276,90 € 6.662,10 € 8.481,80 € 11.240,60 € 14.907,20 € AAZVM 2.456,10 € 2.898,40 € 3.301,90 € 3.868,40 € 5.075,10 € 6.173,20 € 7.678,70 € 9.506,20 € 12.361,90 € 16.094,50 € 16.847,30 € AAZVC 3.612,30 € 4.132,30 € 4.454,30 € 5.602,80 € 6.565,10 € 7.717,50 € 11.283,20 € AAZVC 4.299,10 € 4.881,10 € 5.350,60 € 6.619,40 € 7.593,30 € 8.838,80 € 12.466,70 € 15.784,10 € • Transport of solid material and textile fibers (AZZA P/R). UNDER REQUEST • Fully equipped fans including motor, pulleys, belts, belts guard and shaft guard. Assembled on a base plate. • Flameproof and explosionproof fans with ATEX certified motors. • Fans for air working temperatures up to 250ºC, 300ºC or 450ºC. • Hot-dipped galvanised or stainless steel fans. NOTE Fans are supplied as free shaft. For the price of whole assembled set (motor and transmission execution 9 or 12), please add to the fan cost: motor and corresponding transmission set size prices. Prices in accessories section (p.124). AAZVP 2.595,80 € 2.758,70 € 3.647,30 € 4.178,80 € 4.528,00 € 5.657,10 € 6.611,60 € 8.241,30 € 10.798,20 € AAZVP 3.065,30 € 3.170,00 € 4.337,90 € 4.923,80 € 5.424,30 € 6.669,80 € 7.632,10 € 9.354,90 € 11.977,80 € 15.023,60 € AZZVA 1.695,60 € 1.951,70 € 1.951,70 € 1.951,70 € 2.250,40 € 2.250,40 € 2.778,10 € 3.007,10 € 4.105,10 € - AZZVA 2.157,30 € 2.343,60 € 2.363,00 € 2.479,40 € 2.832,50 € 2.832,50 € 3.453,30 € 3.794,70 € 5.036,30 € - AZZVA 2.510,40 € 2.813,10 € 2.813,10 € 3.166,10 € 3.581,30 € 3.728,70 € 4.466,00 € 4.819,00 € 6.157,70 € - FAN EXECUTION 1 (FREE SHAFT) FAN EXECUTION 9 (FREE SHAFT WITH BACKPACK) FAN CONFIGURATION 12 (FREE SHAFT WITH BASEMENT) 111 ATEX FANS ATEX FANS www.casals.tv 112 ATEX FANS HBX Wall plate axial MANUFACTURING FEATURES • Plate axial fan, circular reinforced frame. • Motor-impeller assembly through a modular system. • Cast aluminium impeller. • Epoxy powder coat finishing. • ATEX standard asynchronous motor. Standard voltages 230V 50Hz for single phase motors, 230/400V 50Hz for three phase, motors up to 5,5 HP and 400/690V 50Hz for higher powers. APPLICATIONS Designed for wall or duct installation, they are suitable for: • General ventilation in closed environments classified as ATEX zone 1 or 2. • Maximum working temperature: 50ºC. ACCESSORIES RFS INT PE RP0 RP1 PC UNDER REQUEST • B form impeller (air flow from impeller to motor), 100% reversible impeller. • 60Hz fans and special voltages. • Fan sizes bigger than 100. In compliance with the 94/9/CE Directive. ATEX II2G certified. For areas 1(gas), 2(gas) or 22(dust). Protection level according to the needs. Notified organism: IMQ (under No. 0051) Identification No.: 43EJ00001 PCP MC HB THREE PHASE RANGE Model HBX 30 T2 0,25kW HBX 30 T4 0,12kW HBX 35 T2 0,37kW HBX 35 T4 0,12kW HBX 40 T2 1,1kW HBX 40 T4 0,25kW HBX 45 T2 1,5kW HBX 45 T2 2,2kW HBX 45 T4 0,37kW HBX 45 T6 0,12kW HBX 50 T4 0,55kW HBX 50 T6 0,25kW HBX 56 T4 0,55kW HBX 56 T4 0,75kW HBX 56 T4 1,1kW HBX 56 T4 1,5kW HBX 56 T6 0,25kW HBX 56 T6 0,37kW HBX 56 T6 0,55kW HBX 63 T4 0,75kW HBX 63 T4 1,1kW HBX 63 T4 1,5kW HBX 63 T4 2,2kW HBX 63 T4 3kW HBX 63 T6 0,37kW HBX 63 T6 0,55kW HBX 63 T6 0,75kW HBX 71 T4 1,1kW HBX 71 T4 1,5kW HBX 71 T4 2,2kW HBX 71 T4 3kW HBX 71 T6 0,55kW HBX 71 T6 0,75kW HBX 71 T6 1,1kW R.P.M. max. 2800 1400 2800 1400 2800 1400 2800 2800 1400 850 1400 900 1400 1400 1400 1400 900 900 900 1400 1400 1400 1430 1430 900 900 910 1400 1400 1430 1430 900 910 910 230 1,17 0,84 1,65 0,84 4,42 1,44 6,01 8,61 1,94 1,08 2,69 1,51 2,69 3,48 4,74 6,31 1,51 2,13 2,85 3,48 4,74 6,31 8,06 11,7 2,13 2,85 4 4,74 6,31 8,06 11,7 2,85 4 5,5 Max. Curr. (A) 400 690 1,68 0,48 0,95 0,48 2,55 0,83 3,48 4,98 1,12 0,62 1,56 0,87 1,56 2,01 2,75 3,65 0,87 1,23 1,65 2,01 2,75 3,65 5 6,8 1,23 1,65 2,3 2,75 3,65 5 6,8 1,65 2,3 3,2 - Rated Power kW Air flow m3/h Sound dB (A) 0,25 0,18 0,37 0,11 1,1 0,25 1,5 2,2 0,37 0,12 0,55 0,25 0,55 0,75 1,1 1,5 0,25 0,37 0,55 0,75 1,1 1,5 2,2 3 0,37 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 3100 1550 5200 2900 8500 4700 12100 13500 7500 5200 10065 6000 11330 12650 13970 15600 8680 9500 10170 14080 16500 18620 21010 23430 11440 12430 13860 20570 22000 23870 27060 15400 17480 19640 70 57 77 60 84 64 85 87 67 54 67 55 70 71 72 73 59 59 60 60 70 71 72 73 60 61 62 75 76 77 78 63 64 65 R.R.P. € II2G EE(x-e) 759,10 708,10 817,20 783,10 1.145,40 915,30 1.173,50 1.271,60 935,00 1.013,50 807,20 803,00 825,90 1.003,60 1.058,50 1.090,20 957,80 821,70 1.021,60 1.247,60 1.302,50 1.334,30 1.498,30 1.726,50 1.065,70 1.265,60 1.261,30 1.384,70 1.416,40 1.580,40 1.808,60 1.347,60 1.343,40 1.498,70 R.R.P. € II2G EE(x-d) 1.003,80 1.034,30 1.521,10 1.167,60 1.523,70 1.351,70 1.426,80 1.862,30 1.347,10 1.197,00 1.428,30 1.227,10 1.452,00 1.573,00 1.665,40 1.827,40 1.206,30 1.250,90 1.297,70 1.524,80 1.755,60 1.917,70 2.292,90 2.550,70 1.374,80 1.546,80 1.836,70 1.861,70 2.023,70 2.399,00 2.656,80 1.647,00 1.662,90 1.826,90 113 ATEX FANS Model HBX 80 T4 2,2kW HBX 80 T4 3kW HBX 80 T4 4kW HBX 80 T6 0,75kW HBX 80 T6 1,1kW HBX 80 T6 1,5kW HBX 80 T6 2,2kW HBX 90 T4 3kW HBX 90 T4 4kW HBX 90 T4 5,5kW HBX 90 T4 7,5kW HBX 90 T6 1,5kW HBX 90 T6 2,2kW HBX 90 T6 3kW HBX 100 T4 5,5kW HBX 100 T4 7,5kW HBX 100 T4 11kW HBX 100 T4 15kW HBX 100 T6 2,2kW HBX 100 T6 3kW HBX 100 T6 4kW R.P.M. max. 1430 1430 1440 910 910 940 940 1430 1440 1440 1440 940 940 960 1440 1440 1460 1460 940 960 960 BOX HBX 230 Max. Curr. (A) 400 690 8,06 11,7 15,2 4 5,5 6,9 9,7 11,7 15,2 6,9 9,7 12,4 9,7 12,4 16,3 5 6,8 8,8 2,3 3,2 4 5,6 6,8 8,8 12 15 4 5,6 7,2 12 15 20,9 27,9 5,6 7,2 9,4 6,9 8,6 6,9 8,6 12,02 16,04 - Rated Power kW Air flow m3/h Sound dB (A) 2,2 3 4 0,75 1,1 1,5 2,2 3 4 5,5 7,5 1,5 2,2 3 5,5 7,5 11 15 2,2 3 4 29700 34980 38700 23100 25840 28600 30620 37540 44320 49370 55040 30580 35390 39910 53080 61590 66450 71510 37740 45690 51450 80 81 82 67 70 71 72 84 85 87 88 75 76 77 89 89 90 91 79 80 81 APPLICATIONS Designed for wall or duct installation, they are suitable for: • Air renewal in buildings and industries. 114 R.R.P. € II2G EE(x-d) 1.555,00 1.783,20 2.107,60 1.318,00 1.473,40 1.712,50 1.993,90 1.822,00 2.045,40 2.141,20 2.568,50 1.751,30 2.072,70 2.267,70 2.415,00 2.742,50 3.539,10 4.547,60 2.246,60 2.541,70 2.826,90 2.566,10 2.823,80 2.887,00 1.994,00 2.110,00 2.547,10 2.610,20 2.904,00 2.967,00 3.618,60 3.632,40 2.690,40 2.896,40 3.267,10 3.795,30 3.809,00 5.018,70 5.719,50 3.073,20 3.443,60 3.628,90 Inline soundproof cabinet axial MANUFACTURING FEATURES • BOX: Galvanised steel soundproof box with Flexiroll Pol Na 30 anthracite grey M1 fire resistance. Easy motor access and fan maintenance through removable panels. • HBX: internal axial fan, circular reinforced frame. Modular motor-impeller assembly. Polyamide impeller with variable pitch angle reinforced with fiberglass. Sparkproof aluminium hoop. Epoxy powder finishing coat. • Motor-impeller assembly through modular system. Variable pitch angle polyamide impeller reinforced with fiberglass. Epoxy powder coat finishing. • Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors, 230/400V 50Hz for three phase, motors up to 4kW and 400/690V 50Hz for higher powers. ACCESSORIES R.R.P. € II2G EE(x-e) RFS INT PE JE 45 • Smoke extraction. • Maximum working temperature: 50ºC. UNDER REQUEST • 100% reversible impeller. • 60Hz fans and special voltages. • Fan sizes bigger than 100. • ATEX models BOX HBX: General ventilation in closed environments classified as ATEX zone 1 or 2. In compliance with the 94/9/CE Directive. With ATEX II2G, II3G marking and certificate. For areas 1(gas), 2(gas) or 22(dust). Protection level according to the needs. Notified organism: IMQ (under No. 0051) Identification No.: 43EJ00001 ATEX FANS THREE PHASE RANGE Model BOX HBX 40 T4 1/3 BOX HBX 45 T2 2 BOX HBX 45 T2 3 BOX HBX 45 T4 1/2 BOX HBX 45 T6 1/3 BOX HBX 50 T4 3/4 BOX HBX 50 T6 1/3 BOX HBX 56 T4 3/4 BOX HBX 56 T4 1 BOX HBX 56 T4 1,5 BOX HBX 56 T4 2 BOX HBX 56 T6 1/3 BOX HBX 56 T6 1/2 BOX HBX 56 T6 3/4 BOX HBX 63 T4 1 BOX HBX 63 T4 1,5 BOX HBX 63 T4 2 BOX HBX 63 T4 3 BOX HBX 63 T4 4 BOX HBX 63 T6 1/2 BOX HBX 63 T6 3/4 BOX HBX 63 T6 1 BOX HBX 71 T4 1,5 BOX HBX 71 T4 2 BOX HBX 71 T4 3 BOX HBX 71 T4 4 BOX HBX 71 T6 3/4 BOX HBX 71 T6 1 BOX HBX 71 T6 1,5 BOX HBX 80 T4 3 BOX HBX 80 T4 4 BOX HBX 80 T4 5,5 BOX HBX 80 T6 1 BOX HBX 80 T6 1,5 BOX HBX 80 T6 2 BOX HBX 80 T6 3 BOX HBX 90 T4 4 BOX HBX 90 T4 5,5 BOX HBX 90T4 7,5 BOX HBX 90 T4 10 BOX HBX 90 T6 2 BOX HBX 90 T6 3 BOX HBX 90 T6 4 BOX HBX 100 T4 7,5 BOX HBX 100 T4 10 BOX HBX 100 T4 15 BOX HBX 100 T4 20 BOX HBX 100 T6 3 BOX HBX 100 T6 4 BOX HBX 100 T6 5,5 R.P.M. max. 1450 2860 2860 1360 880 1410 940 1410 1400 1400 1420 880 940 900 1400 1400 1420 1390 1400 900 900 910 1400 1420 1390 1400 900 910 920 1390 1400 1440 910 920 940 950 1400 1440 1440 1450 940 950 950 1440 1450 1450 1455 950 950 950 Max. Curr. (A) 230 400 690 1,4 6,25 8,28 1,82 1,89 2,46 2,23 2,46 3,67 4,66 6,46 1,89 2,23 3,46 3,67 4,66 6,46 8,83 11,78 2,23 3,46 4,21 4,66 6,46 8,83 11,78 3,46 4,21 5,07 8,83 11,78 15,42 4,21 5,07 7,31 9,53 11,78 15,42 7,31 9,53 12,33 9,53 12,33 16,11 0,81 3,61 4,78 1,05 1,09 1,42 1,29 1,42 2,12 2,69 3,73 1,09 1,29 2 2,12 2,69 3,73 5,1 6,8 1,29 2 2,43 2,69 3,73 5,1 6,8 2 2,43 2,93 5,1 6,8 8,9 2,43 2,93 4,22 5,5 6,8 8,9 11,8 17 4,22 5,5 7,12 11,8 17 24 33 5,5 7,12 9,3 6,81 9,81 6,81 9,81 13,9 19,1 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,25 1,5 2,2 0,37 0,25 0,55 0,25 0,55 0,75 1,1 1,5 0,25 0,37 0,55 0,75 1,1 1,5 2,2 3 0,37 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 2,2 3 4 0,75 1,1 1,5 2,2 3 4 5,5 7,5 1,5 2,2 3 5,5 7,5 11 15 2,2 3 4 4700 12100 13500 7500 5200 10065 6000 11330 12650 13970 15600 8680 9500 10170 14080 16500 18620 21010 23430 11440 12430 13860 20570 22000 23870 27060 15400 17480 19640 29700 34980 38700 23100 25840 28600 30620 37540 44320 49370 55040 30580 35390 39910 53080 61590 66450 71510 37740 45690 51450 61 85 87 67 54 67 55 70 71 72 73 59 59 60 60 70 71 72 73 59 59 60 60 70 71 72 73 60 61 62 75 76 77 78 63 72 84 85 87 88 75 76 77 89 89 90 91 79 80 81 59 67 68 44 50 55 57 58 62 64 54 57 58 62 66 68 77 79 61 62 66 82 84 94 96 78 82 84 102 104 109 90 92 102 105 127 132 148 159 125 128 144 156 167 191 208 136 152 157 307 R.R.P. € II2G EE(x-e) 1.334,60 1.355,40 1.702,10 1.079,90 1.194,60 1.085,80 1.222,00 1.204,70 1.243,70 1.331,60 1.411,80 1.297,20 1.341,10 1.409,40 1.441,00 1.504,50 1.541,20 1.782,40 2.232,30 1.443,30 1.511,60 1.687,30 1.710,50 1.790,70 2.058,90 2.473,60 1.788,30 1.963,80 2.117,40 2.248,30 2.608,20 2.662,90 2.153,10 2.306,80 2.540,80 2.875,10 3.066,20 3.388,30 3.433,50 3.849,20 2.944,30 3.278,40 3.566,40 4.300,60 4.818,90 5.603,40 7.155,90 4.177,20 4.500,70 4.713,30 R.R.P. € II2G EE(x-d) 1.927,40 1.948,20 2.441,80 1.858,00 1.688,00 1.950,00 1.721,90 2.069,10 2.156,40 2.310,80 2.494,30 1.790,60 1.841,00 1.894,20 1.967,20 2.413,00 2.596,60 3.021,70 3.313,90 1.918,90 1.996,40 2.504,90 2.689,50 2.873,10 3.298,40 3.590,40 2.272,90 2.464,20 2.650,00 3.487,60 3.779,70 3.851,20 2.970,80 3.186,70 3.537,70 3.581,30 4.183,10 4.254,70 4.604,80 4.992,90 3.941,00 4.174,60 4.594,50 5.460,70 5.849,10 6.835,60 7.632,20 4.624,40 5.045,70 5.256,00 115 ATEX FANS HMX Long cased axial MANUFACTURING FEATURES • Reinforced fan casing manufactured in rolling steel sheet. • Motor-impeller modular assembly for complete versatility. • Epoxy powder finishing coat. • Cast aluminium impeller with variable pitch angle. • Standard asynchronous ATEX motor. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. UNDER REQUEST • 100% reversible impeller. 5% additional cost. • 60Hz fans and special voltages. • Fan sizes bigger than 100. In compliance with the 94/9/CE Directive. ATEX II2G Certified. For areas 1(gas), 2(gas) or 22(dust). Protection level according to the needs. Notified organism: IMQ (under No. 0051) Identification No.: 43EJ00001 APPLICATIONS Designed for wall or duct installation, they are suitable for: • General ventilation in closed environments classified as ATEX zone 1 or 2. • Maximum working temperature: 50ºC. ACCESSORIES RFS INT PE RP THREE PHASE RANGE Model R.P.M. max. HMX 35 T2 0,37kW HMX 35 T4 0,12kW HMX 40 T2 1,1kW HMX 40 T4 0,25kW HMX 45 T2 1,5kW HMX 45 T2 2,2kW HMX 45 T4 0,37kW HMX 45 T6 0,12kW HMX 50 T4 0,55kW HMX 50 T6 0,25kW HMX 56 T4 0,55kW HMX 56 T4 0,75kW HMX 56 T4 1,1kW HMX 56 T4 1,5kW HMX 56 T6 0,25kW HMX 56 T6 0,37kW HMX 56 T6 0,55kW HMX 63 T4 0,75kW HMX 63 T4 1,1kW HMX 63 T4 1,5kW HMX 63 T4 2,2kW HMX 63 T4 3kW HMX 63 T6 0,37kW HMX 63 T6 0,55kW HMX 63 T6 0,75kW HMX 71 T4 1,1kW HMX 71 T4 1,5kW HMX 71 T4 2,2kW HMX 71 T4 3kW HMX 71 T6 0,55kW HMX 71 T6 0,75kW HMX 71 T6 1,1kW HMX 80 T4 2,2kW HMX 80 T4 3kW HMX 80 T4 4kW HMX 80 T6 0,75kW HMX 80 T6 1,1kW 2800 1400 2800 1400 2800 2800 1400 850 1400 900 1400 1400 1400 1400 900 900 900 1400 1400 1400 1430 1430 900 900 910 1400 1400 1430 1430 900 910 910 1430 1430 1440 910 910 116 Max. Curr. (A) 230 400 690 1,65 0,84 4,42 1,44 6,01 8,61 1,94 1,08 2,69 1,51 2,69 3,48 4,74 6,31 1,51 2,13 2,85 3,48 4,74 6,31 8,06 11,7 2,13 2,85 4 4,74 6,31 8,06 11,7 2,85 4 5,5 8,06 11,7 15,2 4 5,5 0,95 0,48 2,55 0,83 3,48 4,98 1,12 0,62 1,56 0,87 1,56 2,01 2,75 3,65 0,87 1,23 1,65 2,01 2,75 3,65 5 6,8 1,23 1,65 2,3 2,75 3,65 5 6,8 1,65 2,3 3,2 5 6,8 8,8 2,3 3,2 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,37 0,12 1,1 0,25 1,5 2,2 0,37 0,12 0,55 0,25 0,55 0,75 1,1 1,5 0,25 0,37 0,55 0,75 1,1 1,5 2,2 3 0,37 0,55 0,75 1,1 1,5 2,2 3 0,55 0,75 1,1 2,2 3 4 0,75 1,1 5200 2900 8500 4700 12100 13500 7500 5200 10065 6000 11330 12650 13970 15600 8680 9500 10170 14080 16500 18620 21010 23430 11440 12430 13860 20570 22000 23870 27060 15400 17480 19640 29700 34980 38700 23100 25840 77 60 84 64 86 88 67 54 69 55 73 74 75 76 62 62 63 72 73 74 75 76 63 64 65 78 79 80 81 66 67 68 83 84 85 70 73 13 12 22 25 23 24 21 22 26 28 29 30 34 36 26 28 30 38 42 44 55 57 36 38 45 46 49 64 66 42 49 49 69 71 76 60 62 R.R.P. € II2G EE(x-e) 827,60 793,50 1.166,00 935,60 1.232,20 1.517,40 981,70 1.064,20 934,40 1.073,70 960,20 1.053,80 1.111,40 1.171,90 1.054,70 1.099,50 1.169,40 1.310,00 1.367,70 1.401,10 1.605,40 2.029,40 1.258,80 1.328,80 1.508,20 1.453,90 1.487,20 1.681,50 2.105,30 1.415,00 1.584,10 1.741,30 1.932,20 2.356,00 2.457,00 1.834,90 1.992,00 R.R.P. € II2G EE(x-d) 1.531,50 1.178,10 1.555,10 1.366,20 1.577,90 2.027,90 1.495,60 1.340,70 1.621,40 1.413,50 1.644,30 1.758,40 1.864,80 2.032,30 1.390,50 1.436,40 1.484,90 1.601,10 2.006,80 2.174,20 2.561,90 2.828,30 2.384,90 1.627,00 2.090,60 2.074,60 2.241,90 2.629,60 2.896,00 1.729,40 1.869,10 2.038,60 2.853,30 3.119,70 3.184,90 2.382,10 2.262,30 ATEX FANS Model R.P.M. max. HMX 80 T6 1,5kW HMX 80 T6 2,2kW HMX 90 T4 3kW HMX 90 T4 4kW HMX 90 T4 5,5kW HMX 90 T4 7,5kW HMX 90 T6 1,5kW HMX 90 T6 2,2kW HMX 90 T6 3kW HMX 100 T4 5,5kW HMX 100 T4 7,5kW HMX 100 T4 11kW HMX 100 T4 15kW HMX 100 T6 2,2kW HMX 100 T6 3kW HMX 100 T6 4kW 940 940 1430 1440 1440 1440 940 940 960 1440 1440 1460 1460 940 960 960 MAX Max. Curr. (A) 230 400 690 6,9 9,7 11,7 15,2 6,9 9,7 12,4 9,7 12,4 16,3 4 5,6 6,8 8,8 12 15 4 5,6 7,2 12 15 20,9 27,9 5,6 7,2 9,4 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 1,5 2,2 3 4 5,5 7,5 1,5 2,2 3 5,5 7,5 11 15 2,2 3 4 28600 30620 37540 44320 49370 55040 30580 35390 39910 53080 61590 66450 71510 37740 45690 51450 74 75 87 88 90 91 78 79 80 92 92 93 94 82 83 84 68 73 88 93 108 119 85 90 113 121 132 156 171 102 126 134 6,9 8,6 6,9 8,6 12,02 16,04 - R.R.P. € II2G EE(x-e) 2.231,30 2.573,00 2.565,70 2.894,70 2.995,70 3.366,00 2.441,00 2.782,60 3.076,80 3.909,70 4.380,90 5.094,00 6.505,40 3.797,50 4.091,60 4.284,80 R.R.P. € II2G EE(x-d) 2.898,90 2.833,70 3.306,60 3.371,80 4.059,20 4.145,90 3.085,90 3.298,90 3.681,80 4.964,30 5.354,10 6.214,20 6.938,40 4.204,00 4.586,90 4.778,20 Medium pressure centrifugal MANUFACTURING FEATURES • Rolling steel sheet housing. • Cast aluminium impeller. • Epoxy powder finishing coat. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation and ATEX certified EEx-d. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors. APPLICATIONS Designed for inline installation, they are suitable for: • Industrial applications, air extraction or injection. • Cooling of machines and parts. • Clean and slightly dusty air transport. • Maximum working temperature: carried air 130ºC; environment: 60ºC. ACCESSORIES RFS INT PE RA AC UNDER REQUEST • 60Hz fans and special voltages. • 2 speed motors. In compliance with the 94/9/CE Directive. ATEX II2G built. Certified II3G with certified ATEX EEx-d II2G motor for areas 2 (gas) or 22 (dust). BA-400 SIL-C SIL-R THREE PHASE RANGE Model R.P.M. máx. MAX 26 T2 0,37kW MAX 27 T2 0,55kW MAX 28 T2 1,1kW MAX 31 T2 1,5kW 2800 2800 2800 2800 Max. Curr. (A) 230 400 690 1,65 2,33 4,42 6,01 0,95 1,35 2,55 3,48 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,37 0,55 1,1 1,5 870 1100 2150 2550 71 80 80 83 13 14 20 27 R.R.P. € 994,40 1.081,10 1.320,30 1.450,80 117 ATEX FANS MBX Medium pressure centrifugal MANUFACTURING FEATURES • Rolling steel sheet housing. • Completely joined or welded housing. • Single inlet forward curved impeller made of aluminium sheet. • Epoxy powder finishing coat. • Inlet sparkproof ring made of copper or aluminium. • Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. ATEX certified EEx-d. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. MBX 12/5 - 20/8 MBX 22/9 - 28/11 UNDER REQUEST • 60Hz fans and special voltages. • Special ATEX executions. In compliance with the 94/9/CE Directive. ATEX II2G built. Certified II3G with certified ATEX EEx-d II2G motor for areas 2 (gas) or 22 (dust). APPLICATIONS Designed for inline installation, they are suitable for: • General ventilation in closed environments classified as ATEX zone 2 or 22. • Maximum air working temperature from -20ºC to 80ºC. MBX 31/12 - 45/18 ACCESSORIES RFS INT PE RA EI AC BA-400 SIL-C SIL-R THREE PHASE RANGE Model R.P.M. max. MBX 16/6 T2 0,37kW MBX 16/6 T4 0,18kW MBX 18/7 T2 0,75kW MBX 18/7 T4 0,25kW MBX 20/6 T2 0,37kW MBX 20/8 T2 1,1kW MBX 20/8 T4 0,37kW MBX 22/9 T2 1,1kW MBX 22/9 T2 2,2kW MBX 22/9 T4 0,55kW MBX 25/10 T2 2,2kW MBX 25/10 T2 3kW MBX 25/10 T4 1,1kW MBX 28/11 T2 4kW MBX 28/11 T4 2,2kW MBX 28/11 T6 0,75kW MBX 31/12 T4 3kW MBX 31/12 T4 4kW MBX 35/14 T4 3kW MBX 35/14 T4 5,5kW MBX 40/16 T4 5,5kW MBX 40/16 T4 7,5kW MBX 40/16 T6 2,2kW MBX 45/18 T4 5,5kW MBX 45/18 T4 7,5kW MBX 45/18 T4 11kW MBX 45/18 T6 2,2kW 2800 1400 2800 1400 2800 2800 1400 2800 2800 1400 2800 2870 1400 2890 1430 910 1430 1440 1430 1440 1440 1440 940 1440 1440 1460 940 118 Max. Curr. (A) 230 400 690 1,65 1,12 3,03 1,44 1,65 4,42 1,94 4,42 8,61 2,69 8,61 11,1 4,74 14,2 8,06 4 11,7 15,2 11,7 9,7 9,7 0,95 0,65 1,75 0,83 0,95 2,55 1,12 2,55 4,98 1,56 4,98 6,4 2,75 8,2 5 2,3 6,8 8,8 6,8 12 12 15 5,6 12 15 20,9 5,6 6,9 6,9 8,6 6,9 8,6 12,02 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,37 0,18 0,75 0,25 0,37 1,1 0,37 1,1 2,2 0,55 2,2 3 1,1 4 2,2 0,75 3 4 3 5,5 5,5 7,5 2,2 5,5 7,5 11 2,2 1400 1100 1900 1200 880 2100 2200 1800 3000 2700 2600 3200 3500 4000 5000 3600 5700 6800 6000 9000 9000 11000 7000 8000 11000 18000 9000 70 57 68 63 68 68 60 70 74 60 77 78 64 81 68 58 72 73 78 79 78 79 71 80 82 86 76 9,5 9,5 15 10 14 19 15 24 30 22 32 38 33 46 44 37 57 59 63 76 101 110 94 116 119 190 112 R.R.P. EEx-d € 886,50 814,90 1.009,20 933,30 1.077,10 962,70 944,30 1.410,90 1.556,30 1.116,40 1.614,10 1.904,90 1.306,40 2.360,10 1.645,40 1.612,60 2.010,60 2.439,60 2.145,80 2.795,20 2.926,90 3.269,40 2.879,80 3.274,70 3.616,20 5.062,30 2.814,40 ATEX FANS MBPX Medium pressure backward centrifugal, anticorrosion MANUFACTURING FEATURES • Antistatic PE-el housing. • Backward curved impeller in PP plastic. • Motor support made of rolled steel sheet with epoxy powder finishing coat. • Stainless steel nuts and bolts. • Standard asynchronous squirrel-cage motor, IP55, class F insulation. Standard voltages 230/400V 50Hz. Equipped with II2G Eex-d motor. UNDER REQUEST • 60Hz fans and special voltages fans. • Stainless steel motor support. In compliance with the 94/9/CE Directive. ATEX II2G built. Certified II3G with certified ATEX EEx-d II2G motor for areas 2 (gas) or 22 (dust). APPLICATIONS Designed for inline installation, they are suitable for: • Corrosive air transport. • Chemical and petrochemical industry. • General ventilation in closed environments classified as ATEX zone 2. • Laboratories and gas cabinets. • Maximum working temperature: 50ºC. ACCESSORIES RFS INT THREE PHASE RANGE Model MBPX 20 T2 0,18kW MBPX 20 T4 0,12kW MBPX 25 T2 0,37kW MBPX 25 T4 0,12kW MBPX 31 T2 1,5kW MBPX 31 T4 0,25kW MBPX 31 T6 0,18kW MBPX 35 T2 2,2kW MBPX 35 T4 0,37kW MBPX 35 T6 0,18kW MBPX 40 T4 0,55kW MBPX 40 T6 0,25kW MBPX 45 T2 4kW MBPX 45 T4 1,1kW MBPX 45 T6 0,37kW R.P.M. max. 2800 1400 2800 1400 2800 1400 880 2800 1400 880 1400 900 2890 1400 900 Max. Curr. (A) 230 400 0,91 0,84 1,65 0,84 6,01 1,44 1,22 8,61 1,94 1,22 2,69 1,51 14,2 4,74 2,13 0,53 0,48 0,95 0,48 3,48 0,83 0,7 4,98 1,12 0,7 1,56 0,87 8,2 2,75 1,23 Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,18 0,12 0,37 0,12 1,5 0,25 0,18 2,2 0,37 0,18 0,55 0,25 4 1,1 0,37 1100 570 2150 1100 4700 2395 1570 6700 3400 2230 4850 3180 12000 6400 4200 63 47 68 53 76 61 50 76 60 54 68 56 82 64 56 9 9 13 10 26 19 19 32 23 23 33 30 52 41 37 R.R.P. € 1.360,10 1.318,90 1.821,70 1.537,50 2.709,80 1.911,80 1.926,10 3.113,20 2.190,80 2.109,70 2.876,10 2.817,40 4.811,00 3.497,50 3.193,60 119 ATEX FANS MBPCX Medium pressure centrifugal, anticorrosion MANUFACTURING FEATURES • Antistatic PE-el housing. • Forward curved impeller in PP plastic. • Motor support made of rolled steel sheet with epoxy powder finishing coat. • Stainless steel nuts and bolts. • Standard asynchronous squirrel-cage motor, IP55, class F insulation. Standard voltages 230/400V 50Hz. Equipped with II2G Eex-d motors UNDER REQUEST • 60Hz fans and special voltages fans. • Stainless steel motor support. In compliance with the 94/9/CE Directive. ATEX II2G built. Certified II3G with certified ATEX EEx-d II2G motor for areas 2 (gas) or 22 (dust). APPLICATIONS Designed for inline installation, they are suitable for: • Corrosive air transport. • Chemical and petrochemical industry. • Laboratories and gas cabinets. • General ventilation in closed environments classified as ATEX zone 2. • Maximum working temperature: 50ºC. ACCESSORIES RFS INT PE THREE PHASE RANGE Model MBPCX 20 T2 0,25kW MBPCX 20 T4 0,12kW MBPCX 25 T2 0,75kW MBPCX 25 T4 0,18kW MBPCX 28 T2 1,1kW MBPCX 28 T4 0,18kW MBPCX 31 T2 1,5kW MBPCX 31 T4 0,25kW MBPCX 31 T6 0,12kW MBPCX 40 T2 5,5kW MBPCX 40 T2 4kW MBPCX 40 T4 0,75kW MBPCX 40 T6 0,25kW MBPCX 45 T4 1,1kW MBPCX 45 T6 0,37kW MBPCX 50 T4 2,2kW MBPCX 50 T6 0,75kW MBPCX 56 T4 5,5kW MBPCX 56 T6 2,2kW 120 R.P.M. max. 2800 1400 2800 1400 2800 1400 2800 1400 850 2900 2890 1400 900 1400 900 1430 910 1440 940 Max. Curr. (A) 230 400 690 1,17 0,84 3,03 0,84 4,42 1,12 6,01 1,44 1,08 14,2 3,48 1,51 4,74 2,13 8,06 4 9,7 1,68 0,48 1,75 0,48 2,55 0,65 3,48 0,83 0,62 11 8,2 2,01 0,87 2,75 1,23 5 2,3 12 5,6 6,3 6,9 - Rated Power kW Air flow m3/h Sound dB (A) Weight Kg 0,25 0,12 0,75 0,12 1,1 0,18 1,5 0,25 0,12 5,5 4 0,75 0,25 1,1 0,37 2,2 0,75 5,5 2,2 800 440 1500 780 2100 1100 2510 1400 920 5590 4080 2710 1930 3650 2700 5440 4090 9150 8100 74 59 80 64 85 69 90 73 64 91 91 76 65 78 68 80 70 82 71 18 9 29 21 20 16 31 24 20 49 47 31 28 65 65 100 90 115 95 R.R.P. € 1.249,90 1.188,90 1.705,40 1.349,70 2.072,40 1.547,40 2.447,40 1.746,20 1.748,00 4.221,50 3.362,40 2.705,50 2.593,10 5.389,70 5.152,90 6.508,00 6.015,20 8.919,40 7.765,10 ACCESSORIES ELECTRICAL ACCESSORIES MECHANICAL ACCESSORIES www.casals.tv 121 ELECTRICAL ACCESSORIES REGD-1 Manual single phase speed controller Speed controller for single phase voltage (230 Vac - 50 Hz) controllable motors by varying the supplied voltage through angle phase control. External enclosure in white-ivory plastic. Internal enclosure in polyamide. Maximum room temperature: 35ºC. Code Model 300782600 REG Max. Current (A) Voltage (V) Weight Kg 1 230 2,35 REGD-1 R.R.P. € 56,40 Manual single phase speed controller Specially designed for sinus wave speed control. Only available for single phase fans. Terminal wiring. Minimum speed adjustable and potentiometer speed control. Sealed box IP-54 box. Light switch pilot. EMC filter according to the En55014 Standard. SINGLE PHASE RANGE Code Model 960710015 960710030 960710050 960710100 RFS REG 1.5 A REG 3 A REG 5 A REG 10 A Max. Current (A) Voltage (V) 1,5 3 5 10 230 230 230 230 R.R.P. € 74,20 79,80 95,00 167,00 Frequency drive speed controller Specially designed for speed frequency control. ECM filter included. It complies with the main standards: UL/CSA, CE and C/TICK. IP-20 protection. SINGLE PHASE RANGE Code 960002500 960002501 960002503 960002504 960002505 Model RFS 2 0,18kW RFS 2 0,37kW RFS 2 0,75kW RFS 2 1,5kW RFS 2 2,2kW Single phase inlet (V) 3 phase outlet (V) Max. Curr. (A) Power kW Weight Kg 200/240 Monofásica 50/60 Hz 200/240 Monofásica 50/60 Hz 200/240 Monofásica 50/60 Hz 200/240 Monofásica 50/60 Hz 200/240 Monofásica 50/60 Hz 230V 230V 230V 230V 230V 1,4 2,4 4 7,5 10 0,18 0,37 0,75 1,5 2,2 1 1 1 1,5 1,5 R.R.P. € 270,70 292,40 335,70 465,70 592,10 THREE PHASE RANGE 122 Code Model Single phase inlet (V) 3 phase outlet (V) Max. Curr. (A) 960002508 960002510 960002511 960002513 960002514 960002515 960002516 960002517 960002518 960002519 RFS 3 0,75kW RFS 3 1,5kW RFS 3 2,2kW RFS 3 4kW RFS 3 5,5kW RFS 3 7,5kW RFS 3 11kW RFS 3 15kW RFS 3 18,5kW RFS 3 22kW 380/400V Trifásica 50/60 Hz 380/400V Trifásica 50/60 Hz 380/400V Trifásica 50/60 Hz 380/400V Trifásica 50/60 Hz 380/400V Trifásica 50/60 Hz 380/400V Trifásica 50/60 Hz 380/400V Trifásica 50/60 Hz 380/400V Trifásica 50/60 Hz 380/400V Trifásica 50/60 Hz 380/400V Trifásica 50/60 Hz 400V 400V 400V 400V 400V 400V 400V 400V 400V 400V 2,2 3,7 5,1 9,1 12 16 22,5 30,5 41 48 Power Weight kW Kg 0,75 1,5 2,2 4 5,5 7,5 11 15 18,5 22 1,4 1,4 1,4 2,4 2,4 4,7 4,7 9 9 15,4 R.R.P. € 700,30 704,00 725,60 862,80 1.379,00 1.523,40 1.884,40 2.411,40 3.534,10 4.187,60 ELECTRICAL ACCESSORIES INT Safety switch Safety start-stop switch prepared for a safe-lock. Used to stop and lock the fan before any maintenance job. In compliance with the IEC 947-3 standard. IP-65 protection. Code Model 960000512 960000532 INT 3V Max. Curr. (A) Protection index 12 32 IP-65 IP-65 INT 12 INT 32 R.R.P. € 76,30 115,80 Speed selector switch 4 steps (0-1-2-3) start-stop switch selector. Specially designed for the BD3V range. Code Model 960000603 PE Max. Curr. (A) Protection index Application 3 IP-44 BD 3V INT 3V R.R.P. € 23,10 Emergency switch Emergency push button switch, manual twist-release. NC normally closed. NC + NA normally closed or normally open. Code 960002700 960002701 DPS R.R.P. € Model PE-1 NC PE-1 NC+NA 88,20 107,00 Differential pressure transmitter Differential pressure transmitter. It provides a current signal (4-20 mA) proportional to the pressure measurement. It is used together with the RFS (frequency regulator) to control the pressure of an installation. Code 300671201 Model Supply Pressure range Output signal DPS 100 AZ 24Vdc 0-100 Pa 4-20 mA R.R.P. € 317,70 123 ELECTRICAL ACCESSORIES MOTORS Three phase IEC motors FEATURES • Speeds: 2, 4 and 6. • Mounting form: IM B3 (IM 1001). • Supply: 230/400V 50Hz in three phase motors up to 4kW, and 400/690V 50Hz for higher powers. • Closed motors with forced ventilation. • IP 55 protection. • Class F insulation. • Service S1. 2 POLES 4 POLES 6 POLES Power kW Voltage V Mounting form Price € Mounting size Price € Mounting size Price € Mounting size 0,18 0,25 0,37 0,55 0,75 1,10 1,50 2,20 3 4 5,50 7,50 11 15 18,50 22 30 37 40 55 75 90 110 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 400/690 400/690 400/690 400/690 400/690 400/690 400/690 400/690 400/690 400/690 400/690 400/690 400/690 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 B3 73,30 79,50 92,00 98,90 167,70 184,30 214,50 238,00 321,80 392,20 596,60 656,90 998,80 1.043,60 1.207,60 1.546,80 2.053,50 2.280,00 3.111,30 3.760,20 4.275,50 5.376,90 9.995,70 63 63 71 71 80 80 90 90 100 112 135 132 160 160 160 180 200 200 225 250 280 280 315 76,80 92,30 100,50 160,90 177,60 207,80 227,90 294,90 325,10 412,30 596,60 693,30 1.043,60 1.151,70 1.431,20 1.591,40 2.130,70 2.644,20 3.002,10 3.657,80 4.817,00 5.295,60 8.190,60 63 71 71 80 80 90 90 100 100 112 132 132 160 160 180 180 200 225 225 250 280 280 315 89,20 96,20 129,20 138,90 207,80 231,30 318,40 414,90 576,50 656,90 731,50 1.043,60 1.151,70 1.632,20 1.980,70 2.228,90 2.915,40 3.635,90 4.671,90 5.327,40 9.631,70 9.916,10 10.716,30 71 71 80 80 90 90 100 112 132 132 132 160 160 180 200 200 225 250 280 280 315 315 315 TRANSMISSION SETS 124 UNDER REQUEST • 2 speeds motors. • Single phase motors. • Other mounting forms. Size Price € 56 63 71 80 90 100 112 132 160 180 200 225 250 280 315 337,60 337,60 337,60 337,60 399,60 570,40 613,10 713,90 1.028,20 1.086,40 1.315,30 1.664,60 1.812,00 2.444,40 5.536,90 Transmission set with belt protection included. Applicable to the models AAZ and MZ. ELECTRICAL ACCESSORIES RP Protection guard for long cased axial fans Inlet or outlet protection guard. Specially designed to avoid finger contact. Made of welded metal wire. According to ROHS 2002/95/EC Directive. Code 960280100 960290100 960300100 960300101 960310100 960320100 960330100 960330101 960340100 960340101 960340102 960340103 960340104 RP0 Model RP 25 RP 30 RP 35 RP 40 RP 45 RP 50 RP 56 RP 63 RP 71 RP 80 RP 90 RP 100 RP 125 Application R.R.P. € HM 25 HM 30 HM-HH 35 HM-HMF 40 HM-HMF-HH-HHP 45 HM-HMF 50 HM-HMF-HH-HHP 56 HM-HMF-HH-HHP 63 HM-HMF-HH-HHP 71 HM-HH-HMF 80 HM-HMF-HH-HHP 90 HM-HH 100 HM 125 18,00 21,20 25,30 25,50 29,20 36,70 38,20 69,50 72,90 76,00 78,50 94,80 232,80 Outlet protection guard for axial fans Outlet protection guard. Specially designed to avoid finger contact. Made of welded metal wire. According to ROHS 2002/95/EC Directive. Code 980000020 980000240 980000025 980000280 980000030 960001201 980000035 980000350 960001212 980000040 960001211 980000045 960001202 980000050 960001203 980000056 960001204 960001205 960001206 960001207 960001208 960001209 960001210 Model RP0 20 RP0 240 RP0 25 RP0 280 RP0 30 RP0 300 RP0 35 RP0 350 RP0 351 RP0 40 RP0 400 RP0 45 RP0 450 RP0 50 RP0 500 RP0 56 RP0 560 RP0 630 RP0 710 RP0 800 RP0 900 RP0 1000 RP0 1250 Application HJE 20 HA 24 HJE 25 HA 28 HJE-HJB 30 HB 30 HJE-HJB 35 HA 35 HB 35 HJB 40 HB 40 HJB 45 HB 45 HJB 50 HB 50 HJB 56 HB 56 HB 63 HB 71 HB 80 HB 90 HB 100 HB 125 R.R.P. € 23,60 24,90 25,40 28,00 30,20 30,30 34,30 37,10 38,40 39,80 40,70 42,30 43,60 45,30 48,80 49,10 50,20 65,60 86,30 111,90 130,30 141,10 260,20 125 MECHANICAL ACCESSORIES GUARDS, SHUTTERS AND DAMPERS RP1 Inlet protection guard for axial fans Inlet outlet protection guard. Specially designed to avoid finger contact. Made of welded metal wire. According to ROHS 2002/95/EC Directive. Code RI Model 960350100 960360100 960360110 960370100 960370101 960460101 960460102 960380101 960380102 960450101 960420100 960420101 960390101 960390102 960410101 960410102 960400100 960400101 RP1 24 RP1 28 RP1 300 RP1 35 RP1 351 RP1 401 RP1 402 RP1 451 RP1 452 RP1 500 RP1 56 RP1 561 RP1 631 RP1 632 RP1 711 RP1 712 RP1 80 RP1 801 960430100 RP1 90 960430101 960440100 960440101 960550100 RP1 901 RP1 100 RP1 1001 RP1 125 Application R.R.P. € HA 24 HA 28 HB 30 HA 35 HB 35 HB 40 T4 HB 40 T2 HB-HBA-45 T4, T6 HB 45 T2 HB 50 HB 56 T4 0,55kW, T4 0,75kW, T6 HB T4 1,1kW, T4 1,5kW HB 63 T4 0,75kW, T4 1,1kW, T4 1,5kW, T6 HB 63 T4 2,2kW, T4 3kW HB 71 T4 1,1kW, T4 1,5kW, T6 HB 71 T4 2,2kW, T4 3kW HB 80 T6 0,75kW, T6 1,1kW, T8 0,37kW, T8 0,55kW HB 80 T4 2,2kW, T4 3kW, T4 4kW, T6 1,5kW, T6 2,2kW, T8 0,75kW HB 90 T4 3kW, T4 4kW, T6 1,5kW, T6 2,2kW, T8 0,75kW, T8 1,1kW, T8 1,5kW HB 90 T4 5,5kW, T4 7,5kW, T6 3kW, T8 2,2kW HB 100 T4 5,5kW, T4 7,5kW, T6, T8 HB 100 T4 11kW, T4 15kW HB 125 28,10 33,10 34,10 48,80 49,30 55,20 57,10 63,90 64,10 89,30 90,10 90,90 141,40 144,00 163,30 165,90 144,10 183,70 188,70 192,00 206,40 213,20 369,90 Outlet protection guard for BD and BV fans Outlet protection guard. Specially designed to avoid finger contact. Made of welded metal wire. Code 960000401 960000402 960000403 960000404 960000405 960000406 960000407 960000408 960000409 960000411 RM Model Application RI-19 RI-25/13 RI-25/20 RI-25 RI-28/21 RI-28 RI-33/25 RI-33 RI-39 RI-47 R.R.P. € BD-BV 7/7 BD-BV 9/5 BD-BV 9/8 BD-BV 9/9 BD-BV 10/8 BD-BV 10/10 BD-BV 12/9 BD-BV 12/12 BD-BV 15/15 BV 18/18 18,20 17,50 17,00 18,50 28,00 28,30 37,00 37,00 54,60 69,90 Motor side inlet protection guard for BD fans Motor side protection guard specially designed for low pressure direct driven fans. Code 960000801 960000803 960000802 960000804 960000805 126 Model RM-19 RM-25 RM-25/13 RM-28 RM-33 Application BD 7/7 BD 9/9 BD 9/5 BD 10/10 BD 12/12, BD 12/9 R.R.P. € 12,60 18,80 18,00 19,70 34,60 MECHANICAL ACCESSORIES GUARDS, SHUTTERS AND DAMPERS RA-RAI Inlet protection guard for centrifugal fans Inlet protection guard. Specially designed to avoid finger contact. RA 19-39 model made of galvanised steel; RA 10/4-71/22 made of steel with epoxy powder finishing coat; RAI made of stainless steel AISI 304. Code RA 19-39 RA 10/4-71/22 Model 960610100 960630100 960650100 960670100 960690100 RA 19 RA 25 RA 28 RA 33 RA 39 253051901 253061901 253101901 253111901 253171901 253191901 253201901 253281901 RA 10/4 RA 12/5 RA 14/5 RA 16/6 RA 18/7 RA 20/6 RA 22/9 RA 25/10 253361901 253451901 RA 28/11 RA 31/12 253481901 RA 35/14 253511901 RA 40/16 253531901 RA 45/18 243501901 243561901 254541901 RA 50/16 RA 56/18 RA 63/20 243711901 300716102 300716202 300716302 300716502 300716702 300716902 300717102 300717302 300717402 Application R.R.P. € BD 7 BD 9 BD 10 BD 12 BD 15 11,80 16,40 16,40 27,80 37,90 6,30 6,40 6,40 9,40 13,90 12,60 15,10 16,00 RA 71/22 MB 10/4, MA 18-24, MA 24 P/R MB 12/5, MA 25-26, MA P/R 25-26 MB 14/5, MA 27-28, MA P/R 27-28 MB 16/6, AA 47-53, MA 31, MA 31 P/R MB 18/7, AA 59-66-70-45/5, AA P/R 45/5 MB 20/6-20/8 MB 22/9, AA 50/5, AA P/R 50/5, BC 25/10, MZ 22/9, MB P/R 22/9 MB 25/10, MBC 25/10, AA 60/7, AA P/R 60/7, BC 28/11, MBC/FA 25/10, MZ 25/10, MB P/R 25/10 MB 28/11, MBC 28/11, MZ 28/11, MB P/R 28/11 MB 31/12, MBC 31/12, MBR 31/12, MZ 31/12, MBRC 31/10, MBR 31/10, MBC/FA 31/12, BC 35/18, MB P/R 31/12 MB 35/14, MBC 35/14, MBRC 35/11, MBC/FA 35/14, MBR 35/11, MZ 35/11, MZ 35/14, MB P/R 35/14 MB 40/16, MBC 40/16, MZ 40/16, MB P/R 40/16, MBRF 40/12, MBC/FA 40/16, MBR 40/12, MBRC 40/12, MBRC/FA 40/12 MB 45/18, MBR 45/14, MBC 45/18, MBC/FA 45/18, MZ 45/18, MBRF 45/14, MBRC 45/14, MBRC/FA 45/14, MB P/R 45/18 MBR 50/16, MBRF 50/16, MBRC 50/16, MBRC/FA 50/16 MBR 56/18, MBRF 56/18, MBRC 56/18, MBRC/FA 56/18 MBR 63/20, MBRC 63/20, MBRC/FA 63/20, MBRF 63/20, MZ 63/20, MZ 63/25 MBR 71/22, MBRF 71/22, MBRC 71/22, MBRC/FA 71/22 RAI 10/5 RAI 12/6 RAI 13/6 RAI 13/8 RAI 16/8 RAI 18/8 RAI 20/10 RAI 25/13 RAI 28/15 MDI 10/5 MDI 12/6 MDI 13/6 MDI 13/8 MDI 16/8 MDI 18/8 MDI 20/10 MDI 25/13 MDI 28/15 18,70 25,20 25,90 31,50 48,60 59,60 61,30 77,60 74,50 25,20 25,60 29,60 30,50 37,50 55,80 50,30 64,00 75,10 Additional models under inquiry RAI 127 MECHANICAL ACCESSORIES GUARDS, SHUTTERS AND DAMPERS PC Metall gravity shutter Steel sheet frame and aluminium slats. Code 963200100 963220100 963230100 963240100 963250100 963260100 963280100 963290100 PCP Model PC 25 PC 30 PC 35 PC 45 PC 56 PC 71 PC 90 PC 100 Application HA 24-HJEPA 20-HJEPA 25 HA 28-HJEPA-HB-HJBPA 30 HJEPA-HA-HJBPA-HH 35 HJBPA 40, HJBPA-HB-HH-HHP 45 HH-HJBPA 50, HJBPA-HB-HH-HHP 56 HB-HH-HHP 63-71 HH 80, HH-HHP 90, HB 80-90 HB 100 R.R.P. € 61,30 61,00 78,20 154,40 204,40 211,20 260,90 277,20 Plastic gravity shutter Totally made of PVC. UV rays protected. Maximum air speed: 16m/s. Code 963190105 963200105 963220105 963230105 963230106 963240105 963240106 963250105 963250106 963260105 963270105 963280105 963290105 PI Model PCP 20 PCP 25 PCP 30 PCP 35 PCP 40 PCP 45 PCP 50 PCP 56 PCP 63 PCP 71 PCP 80 PCP 90 PCP 100 Application HJEPA 20 HA 24-HJEPA 25 HA 28-HJEPA-HB-HJBPA 30 HJEPA-HA-HJBPA-HH 35 HJBPA 40 HJBPA-HB-HH-HHP 45 HJBPA-HB 50 HJBPA-HB-HH-HHP 56 HJBPA-HB-HH-HHP 63 HB-HH-HHP 71 HH - HB - HBA 80 HH-HHP 90, HB 90 HB 100 R.R.P. € 58,20 56,60 61,30 71,70 71,80 101,90 130,00 173,70 220,50 307,70 344,60 426,60 530,30 Gravity shutter for cabinet fans To be assembled on BVFC, BOX BD and BOX BV fans. Frame and slats made of galvanized steel. Code 970190100 970250100 970280100 970330100 970390100 970470100 128 Model PI 19/19 (7/7) PI 25/25 (9/9) PI 28/28 (10/10) PI 33/33 (12/12) PI 39/39 (15/15) PI 47/47 (18/18) Application BOX BD, BOX BV 7/7 BVFC, BOX BD, BOX BV 9/9 BVFC, BOX BD, BOX BV 10/10 BVFC, BOX BD, BOX BV 12/12 BVFC, BOX BD, BOX BV 15/15 BVFC, BOX BD, BOX BV 18/18 R.R.P. € 57,50 69,50 84,10 108,10 130,60 189,90 MECHANICAL ACCESSORIES GUARDS, SHUTTERS AND DAMPERS OM Butterfly shutter for HTE roof fans Gravity butterfly shutter. Outlet side fitted. Code 963030101 963040101 963050101 963060101 963070101 VIS Model OM 35 OM 40 OM 45 OM 50 OM 56 Application HTE 35 HTE 40 HTE 45 HTE 50 HTE 56 R.R.P. € 85,30 89,80 93,80 98,90 110,10 Outdoor flange with bird guard VIS OUT = Outlet VIS IN = Inlet Code 960000059 960000050 960000051 960000052 960000053 960000054 960000055 960000056 960000057 960000058 960000051 960000052 960000053 960000054 960000060 960000061 960000062 960000063 960000064 960000065 Model VIS OUT 7 VIS OUT 9 VIS OUT 10 VIS OUT 12 VIS OUT 15 VIS OUT 18 VIS OUT 20 VIS OUT 22 VIS OUT 25 VIS OUT 30 VIS IN 7 VIS IN 9 VIS IN 10 VIS IN 12 VIS IN 15 VIS IN 18 VIS IN 20 VIS IN 22 VIS IN 25 VIS IN 30 Application BOX BV, BOX BD 7/7, CLEAN AIR, TWIN BOX BVFC, BOX BV, BOX BD 9/9, CLEAN AIR, TWIN BOX BVFC, BOX BV, BOX BD 10/10, CLEAN AIR, TWIN BOX BVFC, BOX BV, BOX BD 12/12, CLEAN AIR, TWIN BOX BVFC, BOX BV, BOX BD 15/15, CLEAN AIR, TWIN BOX BVFC, BOX BV 18/18, CLEAN AIR, TWIN BOX BVFC, BOX BV 20/20 BVFC, BOX BV 22/22 BVFC, BOX BV 25/25 BVFC, BOX BV 30/28 BOX BV, BOX BD 7/7 BOX BV, BOX BD 9/9 BOX BV, BOX BD 10/10 BOX BV, BOX BD 12/12 BOX BV, BOX BD 15/15 BOX BV 18/18 BOX BV 20/20 BOX BV 22/22 BOX BV 25/25 BOX BV 30/28 R.R.P. € 49,80 57,90 65,30 70,30 82,40 108,20 137,70 160,60 183,60 206,40 65,30 70,30 82,40 108,20 127,30 140,00 163,00 178,30 210,10 318,20 129 MECHANICAL ACCESSORIES GUARDS, SHUTTERS AND DAMPERS S Mounting support for low pressure fans Support to fix centrifugal low pressure fans on flat surfaces. Fans from 7/7 (19/19) to 12/12 (33/33) supplied with supports (included in price). Code 960540100 PO 960001651 960001652 960001653 960001654 960001655 960001656 960001657 960001658 960001659 960001660 960001661 960001662 960001663 BDE-BV 15/15 BV 18/18 R.R.P. € 22,70 Model PO 25 PO 30 PO 35 PO 40 PO 45 PO 50 PO 56 PO 63 PO 71 PO 80 PO 90 PO 100 PO 125 Application HM 25 HM 30 HM, HMF, HH 35 HM, HMF 40 HM, HMF, HH, HHP 45 HM, HMF 50 HM, HMF, HH, HHP 56 HM, HMF, HH, HHP 63 HM, HMF, HH, HHP 71 HM, HMF 80 HM, HMF, HH, HHP 90 HM 100 HM 125 R.R.P. € 22,60 21,40 23,40 24,10 24,60 41,20 41,90 45,00 49,60 50,90 61,80 63,40 74,50 Tilt mounting support for HM Code 960110101 960100101 960120101 960130101 960150101 960140101 130 S 15/18 Application Long cased axial fans mounting support Code PS Model Model PS 35 PS 40 PS 45 PS 56 PS 63 PS 71 Application HM 35 HM 40 HM, HMF, HH 45 HM, HMF 56 HM, HMF, HH, HHP 63 HM, HMF 71 R.R.P. € 139,70 142,10 144,20 166,30 174,40 175,40 MECHANICAL ACCESSORIES SUPPORTS, FEET AND BASES BTI Inclined roof fan support Inclination under request. Code BTI 25 BTI 30 BTI 35 BTI 40 BTI 45 BTI 50 BTI 56 BTI 63 BTI 71 BTI 80 BTI 90 BS Model HMTE 25 HMTE 30 HMTE, HTE 35 HTE 40 HMTE, HTE 45 HTE 50 HMTE, HTE 56 HMTE 63 HMTE 71 HMTE 80 HMTE 90 Application HM 25 HM 30 HM, HMF, HH 35 HM, HMF 40 HM, HMF, HH, HHP 45 HM, HMF 50 HM, HMF, HH, HHP 56 HM, HMF, HH, HHP 63 HM, HMF, HH, HHP 71 HM, HMF 80 HM, HMF, HH, HHP 90 R.R.P. € 274,70 274,70 274,70 274,70 345,40 345,40 345,40 345,40 608,30 608,30 608,30 Motor support for BVC and BVCR fans Designed to assemble the motor on the fan and tighten the belts. Code 960000100 960000101 960000102 960000103 960000104 TM Model BS 25 BS 28 BS 33 BS 39 BS 47 Application BVC-BVCR 9/9 BVC-BVCR 10/10 BVC-BVCR 12/12 BVC-BVCR 15/15 BVC-BVCR 18/18 R.R.P. € 78,80 95,10 99,20 110,30 100,00 Motor support for BV fans Designed to assemble the motor on the fan and tighten the belts. Code 960720100 960730100 960740100 960750100 960760100 960770100 960780100 960790100 Model TM 251 TM 25 TM 281 TM 28 TM 331 TM 33 TM 39 TM 47 Application BV 7/7, BV 9/7 BV 9/9 BV 10/8 BV 10/10 BV 12/9 BV 12/12 BV 15/15 BV 18/18 R.R.P. € 13,70 17,00 16,00 16,80 18,40 23,10 26,00 28,60 131 MECHANICAL ACCESSORIES GUARDS, SHUTTERS AND DAMPERS AC Connection lange For axial (inlet or outlet) and centrifugal (inlet) fans. Code AC 80-225 AC 250-1250 962100100 962120101 962140101 962160101 962180101 962200101 962220101 960003208 960003209 960003211 960003212 960003213 960003214 960003215 960003216 960003217 960003218 960003219 960003220 960003222 Model AC 80 AC 100 AC 130 AC 150 AC 175 AC 200 AC 225 AC 250 AC 300 AC 350 AC 400 AC 450 AC 500 AC 560 AC 630 AC 710 AC 800 AC 900 AC 1000 AC 1250 Application MB 10/4, MA 18-24 MB 12/5, MA 25-26 MB 14/5, MA 27-28 MB 16/6, MA 31, AA 47-53 MB 18/7, AA 45/5-59-66-70 MB 20/6-20/8 MB-MZ 22/9, AA 50/5, BC 25/10 HM 25 HM 30 HM-HH 35 HM 40 HM-HH-HHP 45 HM-HMF 50 HM-HMF-HH-HHP 56 HM-HMF-HH-HHP 63 HM-HMF-HH-HHP 71 HM-HMF-HH 80 HM-HMF-HH-HHP 90 HM-HH 100 HM 125 R.R.P. € 32,70 33,60 36,00 38,40 41,70 44,60 46,80 57,30 66,10 76,60 85,40 98,50 100,20 110,70 129,10 148,40 185,10 216,00 230,50 302,20 Additional models under request EI Circular outlet connection flange Square to circular conversion flange for medium and high pressure centrifugal fans. Code 962100111 962120111 962140111 962160111 962180111 962200111 962200112 962220111 962250111 962280111 962310111 962310112 962350111 962400111 962400112 962450111 962450112 962500111 962500112 962560111 962600111 962630111 962710111 962250112 962280112 962350112 962470111 Model EI 10/4 EI 12/5 EI 14/5 EI 16/6 EI 18/7 EI 20/6 EI 20/8 EI 22/9 EI 25/10 EI 28/11 EI 31/12 EI 31/10 EI 35/14 EI 40/16 EI 40/12 EI 45/18 EI 45/5 EI 50/16 EI 50/5 EI 56/18 EI 60/7 EI 63/25 EI 71/22 EI 25 EI 28 EI 35 EI 47 Additional models under request 132 Application MB 10/4 MB 12/5 MB 14/5 MB 16/6 MB 18/7 MB 20/6 MB 20/8 MB-MZ 22/9 MB-MZ-MBC-MBC/FA 25/10 MB-MZ-MBC-MBC/FA 28/11 MB-MZ-MBC-MBC/FA 31/12 MBR 31/10 MB-MZ-MBC-MBC/FA 35/14, MBR 35/11 MB-MZ-MBC-MBC/FA 40/16 MB-MBR-MBRF-MBC/FA-MBRC/FA 40/12 MB-MZ-MBC-MBC/FA 45/18 AA 45/5 MBR-MBRF-MBC/FA-MBRC/FA 50/16 AA 50/5 MBR-MBRF-MBC/FA-MBRC/FA 56/18 AA 60/7 MZ 63/25, MBR-MBRF-MBC/FA-MBRC/FA 63/20 MBR-MBRF-MBC/FA-MBRC/FA 71/22 BC 25/10 BC 28/11 BC 35/18 AA 47-53-59-66-70 R.R.P. € 76,10 108,00 113,50 117,90 117,90 111,40 126,60 134,50 155,00 161,40 163,70 173,80 178,20 196,40 204,80 216,00 124,70 257,00 148,10 243,90 147,80 265,70 313,90 155,90 158,40 179,10 104,90 MECHANICAL ACCESSORIES COUPLING FLANGES, DAMPER COVERS AND FILTERS MBI Outlet flange for BD and BV fans Code 251161691 251261691 251281691 251331691 251371691 251601691 251521691 252371691 252451691 Model MBI 7/7 MBI 9/7 MBI 9/9 MBI 10/8 MBI 10/10 MBI 12/9 MBI 12/12 MBI 15/15 MBI 18/18 Application BD, BDE, BV 7/7 BD, BV 9/7 BD, BDE, BV 9/9 BD, BV 10/8 BD, BDE, BV 10/10 BD, BV 12/9 BD, BDE, BV 12/12 BD, BV 15/15 BD, BV 18/18 R.R.P. € 9,70 10,60 12,30 17,30 13,50 16,30 15,40 20,80 29,10 UNDER REQUEST: Possible spot welding on fans outlet. MC HB Square frame for HB fans Code 960003151 960003152 960003153 960003154 960003155 960003156 960003157 960003158 960003159 960003160 960003161 Model MC HB 30 MC HB 35 MC HB 40 MC HB 45 MC HB 50 MC HB 56 MC HB 63 MC HB 71 MC HB 80 MC HB 90 MC HB 100 Application HB 30 HB 35 HB 40 HB 45 HB 50 HB 56 HB 63 HB 71 HB 80 HB 90 HB 100 R.R.P. € 49,10 60,60 71,80 81,10 90,10 97,40 108,40 112,50 136,80 182,10 224,20 133 MECHANICAL ACCESSORIES COUPLING FLANGES, DAMPER COVERS AND FILTERS BA-400 Flexible flange 400ºC/2h Avoids transmission of vibrations to the installation. Certified according to the European standard EN 12101-3 400ºC/2h. Code 960002068 960002067 960002066 960002051 960002065 960002052 960002053 960002054 960002055 960002064 960002056 960002057 960002058 960002059 960002061 960002062 960002063 JE 45 Model BA-400 10/12 BA-400 15 BA-400 20 BA-400 25 BA-400 28 BA-400 30 BA-400 35 BA-400 40 BA-400 45 BA-400 50 BA-400 56 BA-400 63 BA-400 70 BA-400 80 BA-400 90 BA-400 100 BA-400 125 Application Ø 100/125 x 160 Ø 160 x 160 Ø 200 x 160 Ø 250 x160 Ø 280 x 160 Ø 315 x 160 Ø 350 x 160 Ø 400 x 160 Ø 460 x 160 Ø 510 x 160 Ø 570 x 160 Ø 630 x 160 Ø 720 x 160 Ø 810 x 160 Ø 910 x 160 Ø 1010 x 160 Ø 1250 x 160 R.R.P. € 40,60 42,50 45,00 47,30 48,90 50,80 52,70 55,20 58,00 64,20 70,40 68,00 88,60 77,10 85,70 86,50 161,10 Flexible joint Flexible joint to fix the fan and the ducting. Avoids transmission of vibrations. Dimensions: two metallic flanges of 45mm each one and a flexible flange of 60mm. Code 300719201 TCA Model JE 45 Application 45 x 60 x 45 R.R.P. € 6,80 Inlet blind cover Allows customization of inlet’s position and shape. Code 960001111 960001112 960001113 960001114 960001115 960001121 960001122 960001123 960001124 960001125 960001131 134 Model TCA6 TCA7 TCA8 TCA9 TCA10 TCA11 TCA12 TCA13 TCA14 TCA15 TCA16 Application BOX BD, BOX BV 7/7 BOX BD, BOX BV 9/9 BOX BD, BOX BV 10/10 BOX BD, BOX BV 12/12 BOX BD, BOX BV 15/15 BOX BV 18/18 BVFC 9/9 BVFC 10/10 BVFC 12/12 BVFC 15/15 BVFC 18/18 R.R.P. € 17,90 20,70 21,70 22,80 25,10 27,10 20,70 21,70 22,80 25,10 27,10 MECHANICAL ACCESSORIES COUPLING FLANGES, DAMPER COVERS AND FILTERS TIAC Inlet-outlet round flanges Allows duct connection. Code Model 960001351 960001352 960001353 960001354 960001355 960001356 960001357 960001358 960001359 960001360 960001361 960001362 960001363 960001364 960001365 960001366 960001367 CP TIAC 1 TIAC 2 TIAC 3 TIAC 4 TIAC 5 TIAC 6 TIAC 7 TIAC 8 TIAC 9 TIAC 10 TIAC 11 TIAC 12 TIAC 13 TIAC 14 TIAC 15 TIAC 16 TIAC 17 Application Ø 250 TAPA IMPULSIÓN BOX BD-BV-CA 7/7 CIRCULAR Ø 300 TAPA IMPULSIÓN BOX BD-BV-CA 9/9 CIRCULAR Ø 355 TAPA IMPULSIÓN BOX BD-BV-CA 10/10 CIRCULAR Ø 400 TAPA IMPULSIÓN BOX BD-BV-CA 12/12 CIRCULAR Ø 500 TAPA IMPULSIÓN BOX BD-BV-CA 15/15 CIRCULAR Ø 600 TAPA IMPULSIÓN BOX BV-CA BVFC 18/18 CIRCULAR Ø 300 TAPA ASPIRACIÓNBVFC 9/9 CIRCULAR Ø 355 TAPA ASPIRACIÓNBVFC 10/10 CIRCULAR Ø 400 TAPA ASPIRACIÓNBVFC 12/12 CIRCULAR Ø 500 TAPA ASPIRACIÓNBVFC 15/15 CIRCULAR Ø 600 TAPA ASPIRACIÓNBVFC 18/18 CIRCULAR Ø 250 TAPA ASPIRACIÓN BOX BD-BV-CA 7/7 CIRCULAR Ø 300 TAPA ASPIRACIÓN BOX BD-BV-CA 9/9 CIRCULAR Ø 355 TAPA ASPIRACIÓN BOX BD-BV-CA 10/10 CIRCULAR Ø 400 TAPA ASPIRACIÓN BOX BD-BV-CA 12/12 CIRCULAR Ø 500 TAPA ASPIRACIÓN BOX BD-BV-CA 15/15 CIRCULAR Ø 600 TAPA ASPIRACIÓN BOX BV-CA 18/18 CIRCULAR R.R.P. € 28,10 34,50 37,40 43,40 48,90 73,10 37,30 39,50 47,40 63,00 79,20 28,10 34,50 37,40 43,40 48,90 73,10 Outlet bend for MBRLP fans 90º bend for vertical discharge, often needed in paint booths. Code Model 960002100 960002101 960002102 FILTERS CP 454 CP 503 CP 561 Application MBRLP 454 MBRLP 503 MBRLP 561 R.R.P. € 248,50 248,50 248,50 Low pressure drop filters for RCIB (heat exchanger) Model FILTRO G4 RCIB 600 FILTRO G4 RCIB 900 FILTRO G4 RCIB 1900 FILTRO G4 RCIB 2800 FILTRO G4 RCIB 3700 FILTRO G4 RCIB 5100 FILTRO F5 RCIB 600 FILTRO F5 RCIB 900 FILTRO F5 RCIB 1900 FILTRO F5 RCIB 2800 FILTRO F5 RCIB 3700 FILTRO F5 RCIB 5100 FILTRO F7 RCIB 600 FILTRO F7 RCIB 900 FILTRO F7 RCIB 1900 FILTRO F7 RCIB 2800 FILTRO F7 RCIB 3700 FILTRO F7 RCIB 5100 FILTRO F9 RCIB 600 FILTRO F9 RCIB 900 FILTRO F9 RCIB 1900 FILTRO F9 RCIB 2800 FILTRO F9 RCIB 3700 FILTRO F9 RCIB 5100 Application RCIB 600 RCIB 900 RCIB 1900 RCIB 2800 RCIB 3700 RCIB 5100 RCIB 600 RCIB 900 RCIB 1900 RCIB 2800 RCIB 3700 RCIB 5100 RCIB 600 RCIB 900 RCIB 1900 RCIB 2800 RCIB 3700 RCIB 5100 RCIB 600 RCIB 900 RCIB 1900 RCIB 2800 RCIB 3700 RCIB 5100 R.R.P. € 37,20 41,90 55,80 65,20 74,50 74,50 107,00 125,70 135,00 144,30 148,90 148,90 102,40 125,70 223,40 283,90 423,50 423,50 107,00 130,30 228,00 293,20 432,80 432,80 135 MECHANICAL ACCESSORIES SILENCERS AND SOUNDPROOF CABINETS SIL-C Circular silencer Designed to reduce fan noise and be assembled to circular fans and ducts. Special connection flanges might be needed to connect directly to fans (please contact the technical service). Code 960002200 960002201 960002202 960002203 960002204 960002205 960002206 960002207 960002208 960002209 960002210 960002211 960002212 960002213 960002214 960002215 960002216 960002217 SIL-R Model Application SIL-C 100/600 SIL-C 125/600 SIL-C 150/600 SIL-C 160/900 SIL-C 200/900 SIL-C 250/900 SIL-C 315/900 SIL-C 355/900 SIL-C 400/1200 SIL-C 500/1200 SIL-C 560/1200 SIL-C 560/1500 SIL-C 630/1200 SIL-C 630/1500 SIL-C 710/1500 SIL-C 800/1500 SIL-C 900/1500 SIL-C 1000/1500 Ø 100 Ø 125 Ø 150 Ø 160 Ø 200 Ø 250 Ø 315 Ø 355 Ø 400 Ø 500 Ø 560 Ø 560 Ø 630 Ø 630 Ø 710 Ø 800 Ø 900 Ø 1000 R.R.P. € 126,90 130,50 155,10 173,80 216,50 287,90 423,50 523,30 600,00 721,40 872,40 1.013,60 1.023,30 1.189,00 1.393,20 1.597,30 1.943,00 2.177,00 Rectangular silencer Designed to reduce fan noise, rectangular duct connection. Code 960002300 960002301 960002302 960002303 960002304 960002305 960002306 960002307 960002308 CI Model SIL-R 1000/900/900 SIL-R 1200/900/900 SIL-R 1400/1200/900 SIL-R 1400/1200/1200 SIL-R 1600/1200/1200 SIL-R 1800/1200/1200 SIL-R 1800/1500/1200 SIL-R 2000/1800/1200 SIL-R 2400/1800/1200 Noise reduction cabinet Noise reduction cabinet for centrifugal fans. Only under request. 136 Application for air-flow up to: (m3/h) 19450 23350 36280 36280 41470 46650 58320 77750 93300 R.R.P. € 1.264,00 1.482,40 2.187,00 2.515,00 2.841,70 3.160,40 4.038,10 4.875,90 5.781,30 TECHNICAL CONCEPTS www.casals.tv 137 MECHANICAL VENTILATION IN GARAGES In March 2007 the complete Edification Technical Code (CTE) came into effect. Its health (HS) and security basic documents in case of fire state establish, among other issues, the standards for mechanical ventilation devices in garages. Mechanical ventilation shall be done through depression and can be effectuated either by mechanical extraction or by mechanical extraction and impulsion. The basic security document in case of fire indicates that the system must be able to extract an air flow of 150l/s for each place, with a maximum contribution of 120l/s per place. This flow coincides with the denoted on the HS3. The number of extraction devices is based on the number of parking places (see table below). Each duct net must have an extractor. PARKING PLACES (P) DUCT NETS P<15 1 15≤P≤80 2 P>80 1 + Integral (P/40) Garages shall have an extraction and inlet opening for every 100m2 of useful area. The distance between the closest extraction openings shall be below 10m. Fans, including the belt driven ones to overcome pressure drops and/or regulate the flow, must have the F30060 classification. There exist 2 basic types of certified fans: those installed inside the hazardous area and those installed outside the hazardous area. 138 STAIR PRESSURIZATION The UNE-EN 12101-6 standard describes the differential pressure systems applied to escape ways, specially in protected stairs. These systems are based on the mechanical injection of outdoor air to the stair box, generating in this way a positive pressure that prevents the products of combustion from getting in the escape ways. In case of fire, the system helps in the evacuation process of the occupants by avoiding or reducing the vertical spread of the fire. The needed flow will depend on the design conditions of the building. In general terms, an air speed through open sections of 0.75m/s will be used when the stair is used as an escape way for occupants, and of 2m/s when the stair is used by the fire extinguishing personnel. The pressurization system must keep a differential pressure of 50Pa and overcome the pressure drop of the installation. An automatic system consisting of a differential pressure probe (DPS), a frequency regulator (RFS) and the right fan according to the needs is recommended. 2m/s 2m/s Air speed criterium 50 Pa Differential pressure criterium (with all doors closed) KITCHEN VENTILATION Industrial kitchens are considered areas of special risk as long as the total installed power of the cooking elements is higher than 20kW. These conducts must be independent from any other extraction or ventilation conduct. Smoke and heat mechanical extractors will be classified as F40090. The extraction flow rate will be estimated from the uptake speed of the base of the range hood. The uptake speed of the base of the range hood will vary depending on its number of open sides. The following uptake speeds are recommended: 0.6m/s in island type range hoods (4 open sides), 0.45m/s in range hoods with 3 open sides, 0.35m/s in range hoods with 2 open sides and 0.25m/s in range hoods with 1 open side. 139 Fans for potentially explosive environments (ATEX) For adjustable locations ATEX ATEX fans are equipped with certified motors and sparkproof devices. The purpose of these mentioned devices is to avoid accidental frictions between the static and the rotatory parts of the fan. Protection aluminium rings are used in axial fans to protect the impeller from the outer main cover. Friction between the aluminium parts does not generate sparks. ATEX SYMBOLS ACCORDING TO CURRENT REGULATION 94/9/CE II 2 G II B T5 TYPE OF TEMPERATURE GAS GROUP GAS (G) AND DUST (D) GROUP AND CATEGORY ATEX LOGO DECLARATION OF CONFORMITY (EC) MAIN POINTS TO SELECT AN ATEX FAN 1. Fan Group GROUP I: fans used to work in mine sites. Casals does not manufacture this particular type of fans. GROUP II: fans used in possible explosive environments. Casals manufactures this type. 2. Fan Category according to risk zone GROUP AND CATEGORY RISK ZONE 22 NOT AVAILABLE DUST ALWAYS PRESENT 21 20 II 2 3 2 PROBABLY 0 II 3 self-aproval by manufacturer 1 ACCIDENTAL 2 GAS Example 1: in a risk zone 1 (gas, explosive environment) a fan from II 2G category is appropriate (where II indicates the group and G indicates gas). Example 2: in a risk zone 22 (dust, accidental explosive environment) a fan from category II 3D is appropriate (where II indicates the group and D indicates dust). 140 Fans for potentially explosive environments (ATEX) For adjustable locations 3. Group and type of temperature Group: determines the explosion level of the gas. Type of temperature: determines the highest acceptable surface temperature on motor surface. Overcoming such temperature implies ignition risks of either the gas or the dust. GAS EXPLOSION GROUP Ignition temperature I IIA Ignition energy higher than 0,18mJ TYPE OF TEMPERATURE ( maximum surface temperature allowed) T1 T2 >450ºC >300ºC T3 T4 T5 T6 >100ºC >85ºC >200ºC >135ºC Methane I-amyl acetate Amyl alcohol Acetaldehyde Acetone n-butane Petrols Ammonia n-butanol Diesel oils Benzene 1-butene Heating oils Ethylacetate Propylacetate n-hexane Methane I-propanol Methanol Vinyl chloride Propane Toluene IIB Ignition energy 0,06 a 0,18 mJ Cyanide hydrogen Coal Gas (lighting gas) 1.3-butadleno Dimethylether 1.4-dioxane Ethyloglicol Ethylene Sulfide hydrogen Diethylether Ethylene oxide IIC Ignition energy lower than 0,06mJ Hydrogen Carbon disulphur Acetylene DUST Ignition temperature dust cloud Ignition temperature for 5mm dust layer Lower explosive limit (LEL) Dust aluminium 530ºC 280ºC 15 g/m3 Brown dust 380ºC 225ºC 60 g/m3 Dust steel 310ºC 300ºC 125 g/m3 Cereals 420ºC 290ºC 60 g/m3 Wood dust 400ºC 300ºC 30 g/m3 Dust milk 440ºC 340ºC 60 g/m3 Paper 540ºC 300ºC 30 g/m3 PVC 530ºC 380ºC 60 g/m3 Soot 620ºC 385ºC 60 g/m3 Sulfide 280ºC 280ºC 30 g/m3 Starch 440ºC 290ºC 125 g/m3 Hard coal 590ºC 245ºC 60 g/m3 Wheat flour 480ºC 450ºC 125 g/m3 Dust zinc 570ºC 440ºC 250 g/m3 Product (dust) 141 Fans for potentially explosive environments (ATEX) For adjustable locations Maximum surface temperature. (Necessary indication for equipment due to be used in explosive dust environments) Maximum surface temperature in case of failure for equipments in contact with dust: - Temperature limit 1 = 2/3 of the minimum ignition temperature for the existing dust. - Temperature limit 2 = Minimum ignition temperature for a 5mm powder layer less 75 Kelvin. The lowest limit temperature in both cases has to be higher than the maximum temperature on the device’s surface. For example, in a wheat flour case: Temperature limit 1 = 2/3 x 480 = 320 ºC Temperature limit 2 = 450 – 75 = 375 ºC Maximum temperature of device’s surface = 320ºC Lower explosion limit (LEL) is in this case 125g/m3. Below this concentration there’s no explosion risk. The following types of temperature are determined according the same criteria as with Gas: TYPE OF TEMPERATURE Type of temperature Casing surface maximum temperature with environment temperature 40ºC T1 T2 T3 T4 T5 T6 450ºC 300ºC 200ºC 135ºC 100ºC 85ºC Following the same wheat flour example, the type of temperature is T2. Furthermore, the motors (engines) for zone 21 have to be IP6X (dust tight). The client is responsible for defining the potential explosive zones where the fans have to be installed. STANDARD ASSEMBLY POSITION Standard industrial fan range assembly position is LG270. The viewer is located in front of the motor LG 0 LG 180 142 RD 0 LG 45 RD 45 RD 180 LG 225 RD 225 LG 90 LG 270 RD 90 LG 135 RD 270 LG 315 RD 135 RD 315 Fans for potentially explosive environments (ATEX) For adjustable locations NECESSARY INFORMATION FOR DEFINING PRODUCTS WHICH SHOULD WORK IN EXPLOSION ENVIRONMENTS ACCORDING TO ATEX DIRECTIVE. Customer: Reference: Date: Contact person: Telephone: Fax: Email: ATEX marking (if known): Please, fill in the following blanks, do not leave blank the function and classification of risk zone: Fan use: FAN Zones Gas 1 Dust 21 2 22 Dangerous substance information (gas and dust fields must be filled): GAS Ignition temperature: Gas state: ºC Explosion group: IIA: IIB: Corrosive: IIC: Toxic: DUST Ignition temperature for a dust cloud: ºC. Ignition temperature for a 5 mm thick dust layer: ºC. Conductive gas: Type of gas: Non-conductive gas: Abrasive: Corrosive: MOTOR Motor data (to be filled in case of being known or having special requirements): Number of starts: per hour: per day: EEx-d EEx-e EEx-nA IP-65 WORK ENVIRONMENT DATA Environment temperature from: ºC to ºC Height: Fan installation: Inlet fan installation: m Indoor: Outdoor: Outlet fan installation: (The default is considered 20ºC, 0m, indoor and uncoupled). 143 CONNECTION DIAGRAMS SINGLE PHASE MOTORS 230V C N C L N L THREE PHASE MOTORS 230/400V 400/690V 230V 400V 400V 690V U2 V2 W2 U2 V2 W2 U2 V2 W2 U2 V2 W2 U1 V1 W1 U1 V1 W1 U1 V1 W1 U1 V1 W1 2 SPEEDS MOTORS 400V DAHLANDER (Y,YY) LOW SPEED U2 V2 U1 HIGH SPEED U2 W2 V1 W1 V2 U1 U2 V2 W2 U1 V1 W1 W2 V1 W1 U2 L1 L2 L3 L1 L2 L3 L1 L2 L3 400V SEPARATE WINDINGS LOW SPEED HIGH SPEED 2U2 2V2 2W2 1U1 1V1 1W1 2U2 2V2 2U2 2V2 2W2 2W2 1U1 1V1 1W1 L1 144 L2 L3 1U1 1V1 L1 L2 1W1 L3 L1 L2 L3 CONNECTION DIAGRAMS BD FAN SINGLE PHASE MOTOR Compatibility chart BD-REG L REG 1,5A N REG 3A REG 5A REG 10A BD 7/7 M4 0,15kW BD 7/7 M6 0,08kW BD 9/5 M6 0,08kW BD 9/7 M6 0,15kW C black red BD 9/9 M4 0,37kW BD 9/9 M4 0,55kW thermical protector white BD 9/9 M6 0,15kW BD 9/9 M6 0,25kW BD 10/8 M6 0,25kW THREE PHASE MOTOR BD 10/10 M4 0,55kW BD 10/10 M6 0,25kW BD 10/10 M6 0,37kW BD 12/9 M6 0,55kW BD 12/9 M6 0,75kW BD 12/12 M6 0,55kW BD 12/12 M6 0,75kW BD 12/12 M6 1,1kW Excessive motor current Bad regulation Good regulation Optimum regulation 3 SPEED BD FAN BD BD BD BD BD 25/25 M6 1/3 3V BD 2/28 M6 1/3 3V blue green black L3 L2 19/19 19/19 25/25 25/25 M4 M6 M4 M6 1/5 3V 1/10 3V 1/2 3V 1/5 3V BD BD BD BD 28/28 28/28 33/33 33/33 M4 M6 M6 M6 3/4 3V 1/2 3V 3/4 3V 1 3V Ground yellowgreen red white black blue grey grey yellow Ground yellow-green T switch L3 L2 L1 L N L1 N L3 T switch L L2 L1 N L3 L2 L1 N SB AND SBE FANS white black C N L Ground 145 CONNECTION DIAGRAMS BT ILF FAN BT ILF 4, 5, 6 BT ILF 8 T N2 HV N3 HV N2 MV N1 LV N N1 LV ~ L L N ~ L L BT ILF TIMER T N2 HV N1 LV N ~ L L BT FAN BT ROOF FAN black red white C N 146 L black red N L yellow-green NOTES: 147 NOTES: 148 NOTES: 149 NOTES: 150 NOTES: 151 SALES CONDITIONS TRANSPORT TERMS: Ex-Works. PURCHASING TERMS: · Only claims before 30 days will be accepted. · Prices excluding VAT. · Casals has the right to modify prices and products without previous warning. RETURNS: · No returns of customized fans will be accepted. In case of standard fans, returns will only be accepted within the first 3 months after delivery. · A written claim form should be filled and agreed by our sales department before any return is accepted. · After an evaluation, if the return is not justified, the fan will be returned and the client will be charged for the transport costs as well as 25% depreciation of the fan. · After an evaluation, if the return is justified, our sales department will arrange collection and credit note, and/or replacement of the fan. This price list cancels any previous edition. Valid as of April 15th 2011. All prices are valid except printing errors. NOTES: 152
Similar documents
industrial angles
AAMHR AAVC AAVG AAVM AAVP AAZA P/R AAZVC AAZVG AAZVM AAZVP AAZZA P/R BC BCD350 BCD500 BCI BD BD 3V BDE BDEM BDR BOX BD BOX BV BOX HB BOX HBF BT
More information