www.casals.tv GENERAL PRICE LIST 2011

Transcription

www.casals.tv GENERAL PRICE LIST 2011
GENERAL PRICE LIST 2011
www.casals.tv
SELECTION SOFTWARE
Free download:
Download the new version of the Casals Ventilación calculation and fans selection software. Visit the DOWNLOADS section at www.casals.tv, where you can download the setup file for free and always up-to-date.
Software online:
Now you can also use the software online, with no need to download or install it on your computer. Visit the
PRODUCT section in our website.
Main uses:
-Search of the suitable fan according to a specific flow and pressure.
-Calculation of ventilation needs in different types of installations.
-Fan reports (general and technical characteristics, dimensions and performance curves).
-Calculation of pressure drop in ventilation systems through a practical graphic application.
New features:
-Search optimization, faster and more accurate.
-Acoustic data, SWL and SPL spectrums for the working point.
-Multiple selection which allows searching for 5, 10 or 500 fans at the same time. It is possible to import and
export data from spreadsheets, ideal for projects.
-Comparison of different fans in one graph.
-Datasheets for fans and accessories in PDF.
-Dynamic graphs, with zoom and pan tools.
-Updates alert.
-Search engine to find fans and accessories.
-Advanced Filter tools for a better definition in searches.
2
THE COMPANY AND ITS EVOLUTION
The history of Casals goes back to the end of the
XIX century (1881) when the founder Francesc Casals
Fransoy opened a small workshop in the centre of
Ripoll (Girona). From the mechanizing of the cast iron
pieces and the making of machinery for factories and
workshops, this small business developed through
the years and became a business dedicated to the
manufacturing of spare parts for tools and afterwards
to the tooling manufacturing. At this point Talleres
Casals was founded, located in a new industrial area
also in Ripoll.
In 1924 Casals started manufacturing the first models of industrial fans. At first the series production systems were applied but they developed into the current
and modern lines of production. In this way Casals
became the leader of the industry.
With time, Talleres Casals diversified the production and nowadays Casals Ventilation, one of its divisions, has its own entity and is independent from
the rest. Located in Sant Joan de les Abadesses, in a
12.000m2 factory, it manufactures over 100 different
types and models of fans, supplying the national and
international market. In the last few years the evolution has been very satisfactory and nowadays the
export percentage exceeds 36% of the benefits. This
growth has driven Casals Ventilation to expand the
physical space and the personnel, and open a new
factory in Ripoll where the low pressure fan series are
produced.
Currently, as a fan manufacturer of fans with over
125 years of experience, Casals Ventilation has a
wide catalogue available in the market of technical
ventilation for building constructions and industrial
fans. In this catalogue the wide range of certified fans
of 400ºC/2h is amongst the most important and noticeable items found. In addition to the professional
technical team prepared to resolve the doubts, Casals
supplies the most appropriate product to satisfy the
needs and projects of the clients.
3
BRANCH OFFICES IN SPAIN
Andalucía
Huelva - Sevilla - Cádiz - Málaga - Córdoba - Jaén - Granada.
CENTRAL
Tel.: 972720150
Fax: 972721053
E-mail: [email protected]
Andorra
Sr. Toni Soler
Tel.: 00 376 364 661
E-mail: [email protected]
Aragón
Zaragoza - Huesca - Teruel - Soria.
CENTRAL
Tel.: 972720150
Fax: 972721053
E-mail: [email protected]
Asturias
Sr. Alfredo Fernández
Tel.: 649 863 890
E-mail: [email protected]
Castilla y León
Salamanca - Valladolid - Yamora - León Palencia.
Sr. Rafael Villagrá
Tel.: 667 502 310
E-mail: [email protected]
Extremadura
Sr. Mario Rodríguez
Tel.: 618.744.444
E-mail: [email protected]
Balears
Sr. Diego Friggeri
Tel.: 636 714 770
E-mail: [email protected]
Catalunya
Sr. José A. Borrallo Aguilera
Tel.: 676061377
E-mail: [email protected]
Sr. Samuel Batlle
Tel.: 619605058
E-mail: [email protected]
Sr. Francesc Bellot
Tel.: 609672597
E-mail: [email protected]
Levante Sur
Alicante - Murcia - Almería - Albacete.
Galicia
Sra. Marta Vega (edificación)
Tel.: 687 775 631
E-mail: [email protected]
Sr. Antonio Suárez (industrial)
Tel.: 678 675 342
E-mail: [email protected]
4
Sr. Diego Friggeri
Tel.: 636 714 770
E-mail: [email protected]
Canarias
CENTRAL
Tel.: 972720150
E-mail: [email protected]
Centro
Madrid - Segovia - Ávila - Toledo - Guadalajara - Cuenca - Ciudad Real.
Sr. Luis Miguel Vázquez
Tel.: 659 951 624
E-mail: [email protected]
Sr. Miguel Ángel Casillas
629 100 944
E-mail: [email protected]
Norte
Cantabria - La Rioja - Navarra - Álava Vizcaya - Guipúzcoa - Burgos.
Sr. Aitor Irusta
Tel.: 627 525 001
E-mail: [email protected]
Castellón - Valencia.
Sr. Aitor Lezama
Tel.: 672 001 835
E-mail: [email protected]
Sr. Juanjo Martínez
Tel.: 629 686 781
E-mail: [email protected]
Sr. Mikel Garagorri
Tel.: 629 604 310
E-mail: [email protected]
Levante Norte
EXPORT BRANCH OFFICES
Export Contact
CASALS VENTILACIÓN
Ctra. Camprodon s/n
17860 Sant Joan de les Abadesses (Girona)
SPAIN
Tel.: +34 972720150
Fax: +34 972721053
E-mail: [email protected]
5
TO TAKE INTO ACCOUNT
MODELS DESCRIPTION
GENERIC DESCRIPTION OF THE MODELS
The description of the fans models in this price list generally follow the same structure. The description is composed by the series name, followed by the
size of the impeller, the type of motor (single phase or three phase), the number of motor poles and its power. In the case of free shaft fans the motor
information will not be shown.
SERIES
SIZE
EXAMPLE WITH MOTOR:
HBF
125
EXAMPLE WITH FREE SHAFT
BST
9/4
1ph / 3ph
POLES
POWER
T
4
22kW
POWER UNITS
The power of the fan motor is described in kW.
For the equivalence in HP, please use the following table:
Power (CV) = 1,36 x Power (kw)
Power (CV) = 0,00136 x Power (w)
DIMENSIONS UNITS
Axial fans impellers are described in cm. EXAMPLE: HMX 80
For centrifugal fans we find the following cases:
LOW PRESSURE “impeller diameter/impeller width” in inches: BV25/20
INDUSTRIAL TYPE 1 “impeller diameter/impeller width” in cm: BV25/10
INDUSTRIAL TYPE 1 “impeller diameter” in mm: MZRL 400
TABLE OF MOST FREQUENT EQUIVALENCES
HP
1/4
1/3
1/2
3/4
1
1,5
2
3
4
5,5
7,5
10
15
20
25
30
KW
0,18
0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
INCHES
5
7
9
10
12
15
18
20
22
24
26
CM
13
19
25
28
33
39
47
51
56
63
68
ACOUSTIC VALUES
About the acoustic values shown in the fans tables:
6
Centrifugal roof fans
Average sound pressure level (SPL) in dB(A), outlet side, measured on a
horizontal plane from 5m.
Cabinet and inline fans, except for BOX HB and its variants
Average sound pressure level (SPL) in dB(A), with both inlet and outlet
ducted, measured in open field from 1,5m.
Axial fans, including axial roof fans, BOX HB and its variants
Average sound pressure level (SPL) in dB(A), inlet side, measured in open
field from a distance of 3 times the impeller diameter with a minimum of
1,5m.
Centrifugal fans without cabinet
Average sound pressure level (SPL) in dB(A), measured in open field from
1,5m with ducted outlet.
Jet fans
Average sound pressure level (SPL) in dB(A) in open field from a distance
of 5m.
ALPHANUMERIC INDEX
AA 45/5-60/7
AA 47-70
AA P/R
AAVA
AAVC
AAVG/N
AAVM
AAVP
AAZA P/R
AAZVA
AAZVC
AAZVG/N
AAZVG/P
AAZVM
AAZVP
AAZZA
AC
BA-400
BC
BCI
BD
BD 3V
BD CUBIC
BDE
BE
BEA S/C
BEH
BEIRM
BERM
BIRM
BOX ANTARES
BOX BD
BOX BD CA
BOX BST
BOX BSTB
BOX BSTBF
BOX BV
BOX BV CA
BOX HB
BOX HBF
BOX HBFX
BOX HBX
BOX RL
BOX RLF
BOX RLFX
BOX SIRIUS
BOX VEGA BP
BS
BST
BT
BT ILF 100
BT ILF 4-8
BT ROOF
BTI
BV
BVC
BVCR
BVFC
103
103
109
104
105
107
108
106
110
111
111
111
111
111
111
111
132
134
77
79
72
74
72
75
34
34
34
34
34
34
35
26
26
29
31
55
27
27
23
40
40
114
25
45
45
35
35
131
78
32
33
33
20
131
76
76
76
52
CFR
CI
CP
CTH
CTH 400º
CTH+KITV
CTH+KITV 400º
DAL
DB
DCB
DG
DHS
DPS
EAA
EAA S
EAA SH
EI
FILTERS
HA
HB
HBA
HBF
HBFX
HBX
HH
HHP
HI
HJB
HJBPA
HJEPA
HJRE
HM
HMA
HMF
HMFX
HMTE
HMX
HTE
HTR
HTRE
INT
INT 3V
JE-45
JF
KBD-KHB-KTE
MA 18-25
MA 26-31
MA P/R
MAX
MB
MB P/R
MBC/FA
MBC/FA 400º
MBCA
MBGR
MBI
MBP
MBPC
35
136
135
18
49
18
49
58
58
57
58
57
123
34
34
34
132
135
64
65
65
38
38
113
70
71
69
63
61
60
62
67
67
42
42
15
116
14
17
17
123
123
134
44
33
80
81
87
117
83
88
86
50
85
97
133
100
101
MBPCX
MBPX
MBR
MBRC F/A
MBRC/FA 400º
MBRF
MBRH
MBRL
MBRLP
MBRM
MBRU
MBX
MBZM P/R
MC HB
MDE
MDI
MOTORS
MZ
MZCA
MZGR
MZRL
MZRM
MZRU
MZZM P/R
OKTOPUS
OM
PC
PCP
PE
PI
PO
PS
RA
RAI
RCIB
REG
REGD-1
RFS
RI
RM
RP
RP0
RP1
S
SB
SBE
SF
SIL-C
SIL-R
SUST
TCA
TIAC
TM
TRANSMISSION SETS
VIS
VMC
VULCAN
120
119
90
91
51
46
98
92
94
95
96
118
89
133
82
99
124
84
102
102
102
102
102
102
35
129
128
128
123
128
130
130
127
127
36
122
122
122
126
126
125
125
126
130
22
21
47
136
136
54
134
135
131
124
129
34
20
7
INDEX
BUILDING TECHNICAL VENTILATION
ROOF FANS
HTE p.14
HMTE p.15
HTR p.17
HTRE p.17
CTH p.18
CTH+KITV p.18
BOX RL p.25
BOX BD p.26
BOX BD CA p.26
BT ILF 100 p.33
KBD-KHB-KTE p.33
VULCAN p.20
BT ROOF p.20
INLINE FANS
SBE p.21
SB p.22
BOX HB p.23
BOX BST p.29
BOX BSTB p.31
BT p.32
BT ILF 4-8 p.33
BOX BV p.27
BOX BV CA p.27
ENERGY SAVING
EAA p.34
BERM p.34
EAA S p.34
CFR p.35
EAA SH p.34
OKTOPUS p.35
BE p.34
BOX SIRIUS p.35
BEA S/C p.34
BEH p.34
BOX ANTARES p.35
BEIRM p.34
BOX VEGA BP p.35
BIRM p.34
RCIB p.36
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
8
HBF p.38
HBFX p.38
BOX RLFX p.45
MBRF p.46
BOX HBF p.40
SF p.47
BOX HBFX p.40
HMF p.42
HMFX p.42
JF p.44
BOX RLF p.45
INDEX
CTH p.49
CTH+KITV p.49
MBC/FA p.50
MBRC/FA p.51
BVFC p.52
SUST p.54
BOX BSTBF p.55
BUILDING
VENTILATION
SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA
DHS p.57
DCB p.57
DB p.58
DAL p.58
INDUSTRIAL
VENTILATION
DOMESTIC RANGE
DG p.58
INDUSTRIAL VENTILATION
ATEX FANS
AXIAL FANS
HJEPA p.60
HJBPA p.61
HJRE p.62
HJB p.63
HA p.64
HB p.65
HBA p.65
BVC p.76
BVCR p.76
HM p.67
HMA p.67
HI p.69
HH p.70
ACCESSORIES
LONG CASED AXIAL FANS
HHP p.71
BD p.72
BD CUBIC p.72
BC p.77
BST p.78
BD 3V p.74
BDE p.75
BV p.76
TECHNICAL
CONCEPTS
CENTRIFUGAL LOW PRESSURE FANS
9
INDEX
CENTRIFUGAL MEDIUM PRESSURE FANS
BCI p.79
MA 18-25 p.80
MA 26-31 p.81
MDE p.82
MA P/R p.87
MB P/R p.88
MBZM P/R p.89
MBR p.90
MBRU p.96
MBGR p.97
MBRH p.98
MDI p.99
MB p.83
MZ p.84
MBCA p.85
MBC/FA p.86
MBRC FA p.91
MBRL p.92
MBRLP p.94
MBRM p.95
MBP p.100
MBPC p.101
BELT DRIVEN p.102
AAVP p.106
AAVG/N p.107
AAVM p.108
MBX p.118
MBPX p.119
CENTRIFUGAL HIGH PRESSURE FANS
AA 47-70 p.103
AAZA P/R p.110
AA 45/5-60/7 p.103
AAVA p.104
AAVC p.105
BELT DRIVEN p.111
ATEX FANS
HBX p.113
10
BOX HBX p.114
HMX p.116
MAX p.117
MBPCX p.120
AA P/R p.109
INDEX
BUILDING
VENTILATION
ELECTRICAL ACCESSORIES
REG p.122
REGD-1 p.122
RFS p.122
INT p.123
INT 3V p.123
DPS p.123
PE p.123
MOTORS AND
TRANSMISSSION
SETS p.124
MECHANICAL ACCESSORIES
INDUSTRIAL
VENTILATION
GUARDS, SHUTTERS AND DAMPERS
PCP p.128
RP0 p.125
PI p.128
RP1 p.126
OM p.129
RI p.126
RM p.126
RA p.127
RAI p.127
PC p.128
VIS p.129
ATEX FANS
RP p.125
SUPPORTS, FEET AND BASES
S p.130
PO p.130
PSp.130
BTI p.131
BS p.131
TM p.131
TIAC p.135
AC p.132
CP p.135
MBI p.133
MC HB p.133
BA-400 p.134
JE-45 p.134
TCA p.134
FILTERS p.135
TECHNICAL
CONCEPTS
EI p.132
ACCESSORIES
COUPLING FLANGES, DAMPER COVERS AND FILTERS
SILENCERS AND SOUNDPROOF CABINETS
SIL-C p.136
SIL-R p.136
CI p.136
11
12
BUILDING TECHNICAL VENTILATION
ROOF FANS
INLINE FANS
ENERGY SAVING
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA
DOMESTIC RANGE
13
ROOF FANS
HTE
Axial with fiberglass cowl
MANUFACTURING FEATURES
•Roof cowl made of reinforced plastic.
•Roof base support and bird protection guard with
epoxy powder finishing coat.
•Variable pitch angle polyamide impeller reinforced with fiberglass.
•Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors,
230/400V 50Hz and for three phase motors.
UNDER REQUEST
• B Form impeller (air flow from impeller to motor)
• 60Hz fans.
APPLICATIONS
Specially designed for roof installation, they are
suitable for:
•Air renewal in buildings and industries.
•Smoke extraction.
• Maximum working temperature: single phase
50ºC, three phase 60ºC.
ACCESSORIES
REG
RFS
INT
PE
BTI
OM
SINGLE PHASE RANGE
Code
Model
R.P.M. max.
267300103
267310103
267350103
267410103
267440103
267460103
HTE 35 M4 0,08kW
HTE 40 M4 0,25kW
HTE 45 M4 0,37kW
HTE 50 M4 0,55kW
HTE 56 M4 0,75kW
HTE 56 M6 0,25kW
1370
1400
1400
1400
1400
900
Max. Curr. (A)
230
400
0,9
2,02
2,77
4,25
5,45
2,07
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,08
0,25
0,37
0,55
0,75
0,25
2610
4230
6750
7650
10120
6940
60
65
66
70
71
68
15
21
28
35
42
41
R.R.P.
€
697,40
740,40
911,70
1.083,80
1.179,60
1.192,60
THREE PHASE RANGE
Code
267300106
267310106
267350106
267410106
267440106
267450106
267460106
14
Model
HTE 35 T4 0,08kW
HTE 40 T4 0,25kW
HTE 45 T4 0,37kW
HTE 50 T4 0,55kW
HTE 56 T4 0,75kW
HTE 56 T4 1,1kW
HTE 56 T6 0,25kW
R.P.M. max.
1400
1400
1400
1400
1400
1400
900
Max. Curr. (A)
230
400
0,04
1,44
1,94
2,69
3,48
4,74
1,51
0,2
0,83
1,12
1,56
2,01
2,75
0,87
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,08
0,25
0,37
0,55
0,75
1,1
0,25
2610
4230
6750
7650
10120
11180
6940
60
65
66
70
71
72
68
15
21
28
35
42
43
41
R.R.P.
€
682,60
736,00
877,00
1.068,10
1.154,00
1.160,60
1.176,90
ROOF FANS
HMTE
Axial with fiberglass cowl
MANUFACTURING FEATURES
• Roof cowl made of reinforced plastic.
• Roof base support and bird protection guard with
epoxy powder finishing coat.
• Polyamide impeller with variable pitch angle reinforced with fiberglass.
• Assembled with fans from HM (long cased) ranges.
• Protection guard in compliance with the ROHS
2002/95 Directive.
• Standard asynchronous squirrel-cage motor, IP55 protection and rated class F insulation. Manufactured with standard voltages 230V 50Hz in single phase motors and 230/400V 50Hz for three
phase motors up to 4kW, and 400/690V 50Hz for
higher powers.
• Smoke extraction.
• Maximum working temperature: single phase
50ºC, three phase 60ºC.
UNDER REQUEST
• B form impeller (air flow from impeller to motor), 100% reversible impeller and cast aluminium
impellers.
• 60Hz fans and special voltages.
• 2 speed motors.
• Assembled with flameproof and explosionproof
HM ATEX fans.
• Hot-dipped galvanised and stainless steel housing.
APPLICATIONS
Specially designed for roof installation, they are
suitable for:
• Air renewal in buildings and industries.
ACCESSORIES
REG
RFS
INT
PE
BTI
15
ROOF FANS
SINGLE PHASE RANGE
Code
269070103
269270103
269100103
269290103
269310103
269330103
269560103
269680103
269760103
Model
HMTE 25 M2 0,12kW
HMTE 25 M4 0,08kW
HMTE 30 M2 0,37kW
HMTE 30 M4 0,12kW
HMTE 35 M4 0,12kW
HMTE 40 M4 0,25kW
HMTE 56 M4 0,55kW
HMTE 63 M6 0,37kW
HMTE 71 M6 0,55kW
R.P.M. max.
2770
1370
2800
1400
1400
1400
1400
900
900
Max. Curr. (A)
230
400
0,98
0,9
2,73
1,1
1,1
2,02
4,25
2,69
3,84
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,12
0,08
0,37
0,12
0,12
0,25
0,55
0,37
0,55
2660
990
2790
1400
2610
4230
9060
9150
12320
70
55
71
56
60
64
73
63
68
12
12
16
14
17
20
36
45
61
-
R.R.P.
€
665,60
666,30
684,40
676,00
749,60
899,00
1.150,40
1.480,90
1.565,70
THREE PHASE RANGE
Code
269070106
269270106
269100106
269290106
269140106
269310106
269150106
269330106
269160106
269350106
269380106
269320106
269620106
269400106
269660106
269680106
269690106
269430106
269740106
269760106
269780106
269420106
269820106
269840106
269860106
269440106
269910106
269450106
269930106
269460106
269960106
16
Model
HMTE 25 T2 0,12kW
HMTE 25 T4 0,08kW
HMTE 30 T2 0,37kW
HMTE 30 T4 0,12kW
HMTE 35 T2 0,37kW
HMTE 35 T4 0,12kW
HMTE 40 T2 1,1kW
HMTE 40 T4 0,25kW
HMTE 45 T2 1,5kW
HMTE 45 T4 0,37kW
HMTE 56 T4 0,55kW
HMTE 56 T6 0,25kW
HMTE 56 T6 0,55kW
HMTE 63 T4 1,1kW
HMTE 63 T4 2,2kW
HMTE 63 T6 0,37kW
HMTE 63 T6 0,55kW
HMTE 71 T4 1,5kW
HMTE 71 T4 3kW
HMTE 71 T6 0,55kW
HMTE 71 T6 1,1kW
HMTE 80 T4 3kW
HMTE 80 T4 4kW
HMTE 80 T6 1,1kW
HMTE 80 T6 2,2kW
HMTE 90 T4 3kW
HMTE 90 T4 4kW
HMTE 90 T4 5,5kW
HMTE 90 T4 7,5kW
HMTE 90 T6 1,5kW
HMTE 90 T6 3kW
R.P.M. max.
2800
1400
2800
1400
2800
1400
2800
1400
2800
1400
1400
900
900
1400
1430
900
900
1400
1430
900
910
1430
1440
910
940
1430
1440
1440
1440
940
960
Max. Curr. (A)
230 400
690
0,67
0,035
1,65
0,84
1,65
0,84
4,42
1,44
6,01
1,94
2,69
1,51
2,85
4,74
8,06
2,13
2,85
4,74
11,7
2,85
5,5
11,7
15,2
5,5
9,7
11,7
15,2
6,9
12,4
0,38
0,2
0,95
0,48
0,95
0,48
2,55
0,83
3,48
1,12
1,56
0,87
1,65
2,75
5
1,23
1,65
2,75
6,8
1,65
3,2
6,8
8,8
3,2
5,6
6,8
8,8
12
15
4
7,2
6,9
8,6
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,12
0,08
0,37
0,12
0,37
0,12
1,1
0,25
1,5
0,37
0,55
0,25
0,55
1,1
2,2
0,37
0,55
1,5
3
0,55
1,1
3
4
1,1
2,2
3
4
5,5
7,5
1,5
3
2660
990
2790
1400
4680
2610
7650
4230
10890
6750
9060
6940
8140
13200
16810
9150
9940
17600
21650
12320
15710
27980
30960
20670
24500
30030
35460
39500
44030
24460
31930
70
55
71
56
77
60
80
64
84
69
72
62
63
74
75
63
64
80
81
66
68
83
84
73
74
87
88
89
91
77
80
12
12
16
14
17
16
23
20
30
28
36
36
37
53
66
45
47
61
78
61
70
101
106
92
103
115
120
135
146
113
141
R.R.P.
€
655,60
659,40
658,90
668,10
744,30
740,00
975,20
886,10
1.066,10
971,00
1.123,60
1.089,70
1.205,20
1.376,30
1.589,00
1.400,30
1.406,20
1.523,90
1.665,90
1.558,90
1.717,10
2.129,10
2.249,50
2.080,40
2.180,90
2.154,90
2.231,60
2.337,20
2.457,70
2.755,40
2.930,20
ROOF FANS
HTR/HTRE Axial, galvanized steel, adjustable inclination base
MANUFACTURING FEATURES
• Completely manufactured in galvanised steel
sheet.
• Polyamide impeller with variable pitch angle reinforced with fiberglass.
• Bird protection guard included.
• 0% standard inclination.
HTR RANGE:
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors.
HTR
HTRE RANGE:
• Static fans, i.e. with no electrical motor (minimum
air speed requested to start the fan: 2,5 m/sec).
APPLICATIONS
Specially designed for roof installation, they are
suitable for:
• Air renewal in buildings and industries.
• Smoke extraction.
• Maximum working temperature: 60ºC.
• 2 speed motors.
• Single phase motors.
• Flameproof and explosionproof fans with ATEX
certified motors and 3-meter RVFV 4x2, 5mm core
cable.
• Custom pitch according to roof slope:
Type A
Model 570: 0% - 18%
Model 740: 0% - 15%
Type B
Model 570: 19% - 38%
Model 740: de 15% a 30%
• Fan inclination under customer’s request. Standard fan inclination: 0%.
• Fans with self-adjustable base support, up to a
38% maximum slope.
• Motorised damper with registered motor in IP-65
box to avoid heat loss in winter.
• ‘Double channel’ function to exhaust air in
dropped ceilings and closed environments at the
same time and save energy and investment.
• Lacquered or stainless steel finishing coat.
UNDER REQUEST
• B form impeller (air flow from impeller to motor),
100% reversible impeller.
• Aluminium impeller.
• 60Hz fans and special voltages.
HTRE
ACCESSORIES
RFS
INT
PE
HTR
Code
300287400
300287500
300287600
300287700
300287800
300287900
300345400
300359800
300349400
300360100
300346100
300433800
Model
HTR 570 T4
HTR 570 T6
HTR 570 T8
HTR 740 T6
HTR 740 T8
HTR 920 T6
HTR-A 570 T4
HTR-A 570 T6
HTR-A 570 T8
HTR-A 740 T6
HTR-A 740 T8
HTR-B 570 T4
HTR-B 570 T6
HTR-B 570 T8
HTR-B 740 T6
HTR-B 740 T8
R.P.M. max.
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1400
900
680
910
680
940
1400
900
680
910
680
1400
900
680
910
680
0,55
0,25
0,09
1,1
0,55
2,2
0,55
0,25
0,09
1,1
0,55
0,55
0,25
0,09
1,1
0,55
9060
6940
5665
15710
11780
28310
9060
6940
5665
15710
11780
9060
6940
5665
15710
11780
72
60
55
70
63
81
72
60
55
70
63
72
60
55
70
63
52
52
52
67
67
89
52
52
52
67
67
52
52
52
67
67
Air flow
m3/h
Weight
Kg
1912
3225
4987
52
67
89
R.R.P.
€
1.442,10
1.457,60
1.457,60
2.389,70
2.389,70
3.543,90
1.545,50
1.545,50
1.611,80
2.437,70
2.437,70
1.545,50
1.545,50
1.611,80
2.437,70
2.437,70
HTRE
Code
300288000
300288100
300288200
Model
HTRE 570
HTRE 740
HTRE 920
R.R.P.
€
954,50
1.045,80
1.470,60
17
ROOF FANS
CTH
Centrifugal, PE cowl
MANUFACTURING FEATURES
• Roof cowl made of polyethylene UV resistant.
• Structure, roof base support and bird protection
guard made of galvanised steel.
• High Efficiency backward curved impellers of galvanised steel.
• Vertical discharge when adding the accessory
KITV.
• Standard asynchronous motor with IP-55 protection and Class F insulation. Manufactured with
standard voltages: 230V 50Hz in single phase motors, 230/400V 50Hz in three phase motors and
400V 50Hz in 2 speed motors.
CTH (horizontal)
• Air renewal in buildings and industries.
• Industrial and professional kitchen hoods.
• Maximum continuous operation temperature:
80ºC.
UNDER REQUEST
• Security switch mounted and wired.
• 60Hz and special voltages.
• Sparkproof fans with ATEX certified motors.
APPLICATIONS
Specially designed for roof installation, they are
suitable for:
• Smoke extraction.
• Smoke emergency exhaust with motor outside the
hazardous area (400ºC/2h certificate).
CTH + KITV (vertical)
ACCESSORIES
REG
RFS
INT
PE
SINGLE PHASE RANGE
Code
Model
R.P.M. max.
Max. Curr.
(A) 230
Rated Power
kW
Air flow
m3/h
Weight Kg
CTH
Weight Kg
CTH+KITV
300815900
300816000
300816100
300816200
300816300
300816400
300816500
300816600
300816700
CTH 28 M4 0,22kW
CTH 32 M4 0,22kW
CTH 36 M4 0,22kW
CTH 40 M4 0,37kW
CTH 45 M4 0,75kW
CTH 45 M6 0,25kW
CTH 50 M4 1,1kW
CTH 50 M6 0,37kW
CTH 56 M6 0,75kW
1450
1450
1450
1450
1450
950
1450
950
950
2,2
2,2
2,2
3,1
5,4
2,3
7
3
6,5
0,22
0,22
0,22
0,37
0,75
0,25
1,1
0,37
0,75
1300
1850
2700
3750
5500
3670
7500
5000
6940
22
22
24
32
38
33
43
37
62
26
26
28
40
46
41
51
45
75
Air flow
m3/h
Weight Kg
CTH
Weight Kg
CTH+KITV
1300
1850
1240
2700
1800
3750
2500
5500
3670
7500
5000
10400
6940
5200
9900
7430
15000
11250
20000
15000
22
22
20
23
21
31
29
35
34
41
37
67
60
60
74
73
111
105
136
131
26
26
24
27
25
39
37
43
42
49
45
80
73
73
87
86
132
126
157
152
R.R.P. €
CTH
645,50
653,10
717,70
903,70
1.013,90
1.040,40
1.222,70
1.211,30
1.587,20
R.R.P. €
CTH+KITV
706,10
714,70
780,30
1.012,70
1.123,90
1.151,40
1.334,70
1.324,30
1.756,80
THREE PHASE RANGE
Code
300816800
300816900
300817000
300817100
300817200
300817300
300817400
300817500
300817600
300817700
300817800
300817900
300818000
300818100
300818200
300818300
300818400
300818500
300818600
300818700
18
Model
CTH 28 T4 0,25kW
CTH 32 T4 0,25kW
CTH 32 T6 0,25kW
CTH 36 T4 0,25kW
CTH 36 T6 0,25kW
CTH 40 T4 0,37kW
CTH 40 T6 0,25kW
CTH 45 T4 0,75kW
CTH 45 T6 0,37kW
CTH 50 T4 1,1kW
CTH 50 T6 0,37kW
CTH 56 T4 2,2kW
CTH 56 T6 0,75kW
CTH 56 T8 0,37kW
CTH 63 T6 1,5kW
CTH 63 T8 0,75kW
CTH 71 T6 2,2kW
CTH 71 T8 1,1kW
CTH 80 T6 4kW
CTH 80 T8 2,2kW
R.P.M. max.
1450
1450
950
1450
950
1450
950
1450
950
1450
950
1450
950
725
950
725
950
725
950
725
Max. Curr. (A) Rated Power
kW
230 400
0,48
0,48
0,5
0,48
0,5
0,64
0,71
1,13
0,71
1,52
0,71
2,77
1,27
0,78
2,19
1,39
3,12
1,85
5,31
3,44
0,84
0,84
0,87
0,84
0,84
1,1
1,23
1,95
1,23
2,6
1,23
4,8
2,2
1,35
3,8
2,4
5,4
3,2
9,2
5,96
0,25
0,25
0,25
0,25
0,25
0,37
0,25
0,75
0,37
1,1
0,37
2,2
0,75
0,37
1,5
0,75
2,2
1,1
4
2,2
R.R.P.
CTH
609,90
630,10
630,10
630,10
630,10
775,50
775,50
872,40
832,00
1.046,10
981,40
1.397,40
1.268,20
1.336,90
1.619,60
1.462,10
1.898,30
1.861,90
2.152,70
2.306,20
R.R.P.
CTH+KITV
670,50
690,70
690,70
690,70
690,70
884,50
884,50
981,40
941,00
1.155,10
1.090,40
1.567,00
1.437,80
1.506,50
1.789,20
1.631,70
2.177,00
2.140,60
2.431,40
2.584,90
ROOF FANS
THREE PHASE RANGE 2 SPEEDS
Code
Model
R.P.M.
max.
Max. Curr.
(A) 400V
Rated Power
kW
Air flow
m3/h
Weight Kg
CTH
Weight Kg
CTH+KITV
300818800
300818900
300819000
300819100
300819200
300819400
300819300
300819500
300819600
300819800
300819700
300819900
300820000
300820100
300820200
300820300
300820400
300820500
300820600
CTH 32 T4/T8 0,37-0,08kW
CTH 36 T4/T8 0,37-0,08kW
CTH 40 T4/T8 0,37-0,08kW
CTH 45 T4/T8 0,8-0,2kW
CTH 45 T6/T8 0,25-0,12kW
CTH 50 T4/T6 1,1-0,3kW
CTH 50 T4/T8 1,2-0,3kW
CTH 50 T6/T8 0,37-0,2kW
CTH 50 T6/T12 0,37-0,07kW
CTH 56 T4/T6 2,2-0,7kW
CTH 56 T4/T8 2,2-0,55kW
CTH 56 T6/T8 0,75-0,37kW
CTH 56 T6/T12 0,75-0,2kW
CTH 63 T6/T8 1,5-0,75kW
CTH 63 T6/T12 1,5-0,75kW
CTH 71 T6/T8 2,2-1,3kW
CTH 71 T6/T12 2,2-0,55kW
CTH 80 T6/T8 4- 1,1kW
CTH 80 T6/T12 4-1,0kW
1450/725
1450/725
1450/725
1450/725
950/725
1450/950
1450/725
950/725
950/450
1450/950
1450/725
950/725
950/450
950/725
950/450
950/725
950/450
950/725
950/450
1,8/0,5
1,8/0,5
1,8/0,5
2/0,9
1/0,94
3/1,5
2,9/1,3
1,5/1,1
1,59/0,7
5,2/2,5
5/2
2,7/1,7
2,4/1
4/3
4,3/1,7
6,5/5
6,4/2,6
11,3/4,9
12,6/5,2
0,37/0,08
0,37/0,08
0,37/0,08
0,8/0,2
0,25/0,12
1,1/0,3
1,2/0,3
0,37/0,2
0,37/0,07
2,2/0,7
2,2/0,55
0,75/0,37
0,75/0,15
1,5/0,75
1,5/0,75
2,2/1,3
2,2/0,55
4/1,1
4/1,0
1850/930
2700/1350
3750/1880
5500/2750
3670/2750
10400/6940
7500/3750
5000/3750
5000/2500
10400/6940
10400/5200
6940/5200
6940/3470
9900/7430
9900/4950
15000/11250
15000/7500
20000/15000
20000/10000
22
23
31
36
33
44
44
37
41
71
80
62
63
93
75
127
116
145
131
26
27
39
44
41
52
52
45
49
84
93
75
73
106
88
148
137
166
152
R.R.P.
CTH
735,10
735,10
880,50
997,60
1.074,30
1.288,40
1.171,30
1.252,00
1.134,90
1.676,10
1.510,50
1.619,60
1.579,20
1.813,40
2.092,10
2.209,20
2.512,20
2.770,60
2.867,60
R.R.P.
CTH+KITV
709,6
709,6
880,3
985,6
1.054,50
1.246,90
1.141,70
1.109,00
1.214,30
1.644,40
1.495,60
1.557,30
1.593,60
1.318,30
1.767,80
2.484,80
2.212,60
2.804,30
2.490,80
19
ROOF FANS
VULCAN
Centrifugal, special for fireplaces and barbecues, 200ºC continuous
MANUFACTURING FEATURES
• Bird protection guard included.
• Manufactured with standard voltages:
230V/50Hz.
• Structure in galvanised steel, external parts in
three options:
VULCAN ST: galvanised steel
VULCAN AL: anodized aluminium
VULCAN CO: copper
APPLICATIONS
Specially designed for smoke extraction up to
200ºC in fireplaces and barbecues.
VULCAN-ST
ACCESSORIES
Model
INT
PE
R.P.M. max.
I (A)
230V
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1400
0,42
0,09
1000
52
18
VULCAN-ST
BT ROOF
578,40
Centrifugal, small applications
MANUFACTURING FEATURES
• Steel sheet set with epoxy powder finishing coat.
• Roof base support and bird protection guard.
• Assembled with fans from BT range.
• Asynchronous external rotor with thermal protector and greased for life ball bearings.
• IP-44 protection and rated class B insulation according to DIN 40.050 h1. Standard voltages 230V
50Hz.
ACCESSORIES
R.R.P.
€
REG
INT
APPLICATIONS
Specially designed for roof installation, they are
suitable for:
• Air renewal in bathrooms and small closed environments.
• Maximum working temperature: 50ºC.
PE
SINGLE PHASE RANGE
Code
300740800
300740900
20
Model
BT ROOF 150
BT ROOF 250
R.P.M. max.
Max. Curr. (A)
230
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
2450
2600
0,43
0,85
0,07
0,18
450
1180
38
46
5,6
8,8
R.R.P.
€
214,10
267,60
INLINE FANS AND ENERGY SAVING
SBE
Centrifugal in low profile cabinet, external rotor motor
MANUFACTURING FEATURES
• Completely manufactured in galvanised steel
sheet including the impeller.
• Inlet and outlet circular flanges to help the duct
fans assembly.
• External wiring box.
• Open-up design of the motor to make cleaning
and maintenance easier.
• Asynchronous external rotor, IP-44 protection and
rated class B insulation according to DIN 40.050
h1 and greased for life ball bearings. Standard voltages 230V 50Hz.
ACCESSORIES
REG
INT
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Air renewal in bathrooms and small closed environments.
• Perfect for installation in dropped ceilings or outdoors.
• Maximum working temperature: 50ºC.
PE
SINGLE PHASE RANGE
Model
SBE 10-24
SBE 12-34
SBE 15-44
SBE 16-44
SBE 20-54
SBE 25-64
SBE 31-64
R.P.M. max.
2730
2640
2530
2540
1380
1380
1350
Max. Curr. (A)
230
400
0,58
0,59
0,82
0,82
0,90
0,86
0,93
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,11
0,11
0,17
0,17
0,17
0,17
0,20
280
390
565
599
840
980
1210
58
62
64
66
59
60
62
4,4
4,6
4,9
5
9,7
10,2
11
R.R.P.
€
150,40
155,00
159,50
161,60
232,00
265,80
308,90
21
INLINE FANS AND ENERGY SAVING
SB
Centrifugal in low profile soundproof cabinet, external rotor motor
MANUFACTURING FEATURES
• Completely manufactured in galvanised steel
sheet including the impeller.
• Soundproof box with Flexiroll Pol Na 30 Anthracite grey, M1 fire resistance insulated panels.
• Inlet and outlet circular flanges to make the duct
fan assembly easier.
• Asynchronous external rotor, IP-44 protection and
rated class B insulation according to DIN 40.050
h1 and greased for life ball bearings. Standard voltages 230V 50Hz.
ACCESSORIES
REG
INT
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Air renewal in bathrooms and small closed environments.
• Perfect for installation in dropped ceilings and
outdoors.
• Maximum working temperature: 50ºC.
PE
SINGLE PHASE RANGE
Code
240120143
240150143
240200143
240210143
240250143
240260143
240350143
240360143
22
Model
SB 125/H
SB 150/H
SB 200/H
SB 200/L
SB 250/H
SB 250/L
SB 355/H
SB 355/L
R.P.M. max.
Max. Curr. (A)
230
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
2700
2600
2600
2450
2660
2600
1400
1350
0,48
0,96
0,67
0,42
0,92
0,67
0,76
0,55
0,11
0,21
0,14
0,1
0,2
0,14
0,18
0,12
400
550
875
700
1300
1100
2500
2100
30
40
45
44
49
47
52
51
4,5
6,2
7,5
7,5
9,75
9,75
26
26
R.R.P.
€
193,30
222,40
264,00
258,00
275,50
276,90
525,20
519,70
INLINE FANS AND ENERGY SAVING
BOX HB
Axial in soundproof cabinet
MANUFACTURING FEATURES
• BOX: soundproof galvanised steel box with Flexiroll Pol Na 30 anthracite grey M1 fire resistance
insulated panels. Easy motor access and fan maintenance through removable panels.
Internal fan:
• HB: axial fan, circular reinforced frame. Motorimpeller assembly through a modular system. Variable pitch angle polyamide impeller reinforced with
fiberglass. Epoxy powder finishing coat.
• HBA: axial fan, circular reinforced frame. Motorimpeller assembly through a modular system. Cast
aluminium impeller with variable pitch angle. Epoxy
powder finishing coat.
APPLICATIONS
Designed for wall or duct installation, they are suitable for:
• Air renewal in buildings and industries.
• Smoke extraction.
• Maximum working temperature: single phase
50ºC, three phase 60ºC.
UNDER REQUEST
• B form, 100% reversible impeller.
• 60Hz fans and special voltages.
• ATEX models BOX HBX: general ventilation in
closed environments classified as ATEX zone 1 or 2.
• Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors,
230/400V 50Hz for three phase motors up to 4kW,
and 400/690V 50Hz for higher powers.
ACCESSORIES
REG
INT
PE
RFS
RP0
RP1
JE 45
SINGLE PHASE RANGE
Code
Model
R.P.M.
max.
260410x43
260470x43
260480x43
270450x43
260500x43
260510x43
260560x43
260600x43
260680x43
260760x43
BOX HB 40 M4 0,25kW
BOX HB 45 M4 0,37kW
BOX HB 45 M6 0,12kW
BOX HB 45 M6 0,25kW
BOX HB 50 M4 0,55kW
BOX HB 50 M6 0,25kW
BOX HB 56 M4 0,55kW
BOX HB 56 M6 0,25kW
BOX HB 63 M6 0,37kW
BOX HB 71 M6 0,55kW
1400
1400
900
900
1400
900
1400
900
900
900
Max. Curr. (A)
230
400
2,02
2,77
1,05
2,07
4,25
2,07
4,25
2,07
2,69
3,84
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,25
0,37
0,12
0,25
0,55
0,25
0,55
0,25
0,37
0,55
4700
7500
5200
5500
10065
6000
11330
8680
11440
15400
61
68
51
52
67
55
70
58
63
68
49
45
44
45
49
50
52
49
52
59
-
R.R.P. €
R.R.P. €
Polyamide Aluminium
758,3
778,4
926,8
937,3
817
936,3
909,9
1.011,70
983,7
1.166,90
856,8
879,6
1.047,30
1.059,20
923,2
1.058,00
1.028,10
1.143,20
1.111,50
1.318,60
THREE PHASE RANGE
Code
260400x46
260410x46
260450x46
260460x46
260470x46
260480x46
260480x46
260500x46
260510x46
260560x46
260570x46
260580x46
260590x46
260600x46
260610x46
Model
BOX HB 40 T2 1,1kW
BOX HB 40 T4 0,25kW
BOX HB 45 T2 1,5kW
BOX HB 45 T2 2,2kW
BOX HB 45 T4 0,37kW
BOX HB 45 T6 0,12kW
BOX HB 45 T6 0,25kW
BOX HB 50 T4 0,55kW
BOX HB 50 T6 0,25kW
BOX HB 56 T4 0,55kW
BOX HB 56 T4 0,75kW
BOX HB 56 T4 1,1kW
BOX HB 56 T4 1,5kW
BOX HB 56 T6 0,25kW
BOX HB 56 T6 0,37kW
R.P.M.
max.
2800
1400
2800
2800
1400
900
850
1400
900
1400
1400
1400
1400
900
900
Max. Curr. (A)
230 400 690
4,42
1,44
6,01
8,61
1,94
0,52
1,08
2,69
1,51
2,69
3,48
4,74
6,31
1,51
2,13
2,55
0,83
3,48
4,98
1,12
0,3
0,62
1,56
0,87
1,56
2,01
2,75
3,65
0,87
1,23
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,1
0,25
1,5
2,2
0,37
0,12
0,25
0,55
0,25
0,55
0,75
1,1
1,5
0,25
0,37
8500
4700
12100
13500
7500
5200
5500
10065
6000
11330
12650
13970
15600
8680
9500
85
61
85
87
67
53
54
67
55
70
71
72
73
59
59
67
59
67
68
44
49
50
49
50
52
53
57
59
49
52
R.R.P. €
R.R.P. €
Polyamide Aluminium
746,6
701,4
854,3
888
774,2
765,1
777,3
807,5
787,7
883,4
903,9
1.026,20
1.057,70
862,5
969,6
843,6
792,6
965,3
1.003,50
874,8
864,6
878,4
912,5
890,1
998,3
1.021,40
1.159,60
1.195,20
974,6
1.095,70
23
INLINE FANS AND ENERGY SAVING
Code
R.P.M.
max.
Model
260620x46
260630x46
260640x46
260650x46
260660x46
260670x46
260680x46
260690x46
260700x46
260710x46
260720x46
260730x46
260740x46
260760x46
260770x46
260780x46
260800x46
260810x46
260820x46
260830x46
260840x46
260850x46
260860x46
260900x46
260910x46
260920x46
260930x46
260940x46
260950x46
260960x46
260100x46
260110x46
260120x46
260130x46
260140x46
260150x46
260160x46
260220x46
260230x46
260240x46
260250x46
260260x46
260270x46
260280x46
260290x46
BOX HB 56 T6 0,55kW
BOX HB 63 T4 0,75kW
BOX HB 63 T4 1,1kW
BOX HB 63 T4 1,5kW
BOX HB 63 T4 2,2kW
BOX HB 63 T4 3kW
BOX HB 63 T6 0,37kW
BOX HB 63 T6 0,55kW
BOX HB 63 T6 0,75kW
BOX HB 71 T4 1,1kW
BOX HB 71 T4 1,5kW
BOX HB 71 T4 2,2kW
BOX HB 71 T4 3kW
BOX HB 71 T6 0,55kW
BOX HB 71 T6 0,75kW
BOX HB 71 T6 1,1kW
BOX HB 80 T4 2,2kW
BOX HB 80 T4 3kW
BOX HB 80 T4 4kW
BOX HB 80 T6 0,75kW
BOX HB 80 T6 1,1kW
BOX HB 80 T6 1,5kW
BOX HB 80 T6 2,2kW
BOX HB 90 T4 3kW
BOX HB 90 T4 4kW
BOX HB 90 T4 5,5kW
BOX HB 90 T4 7,5kW
BOX HB 90 T6 1,5kW
BOX HB 90 T6 2,2kW
BOX HB 90 T6 3kW
BOX HB 100 T4 5,5kW
BOX HB 100 T4 7,5kW
BOX HB 100 T4 11kW
BOX HB 100 T4 15kW
BOX HB 100 T6 2,2kW
BOX HB 100 T6 3kW
BOX HB 100 T6 4kW
BOX HB 125 T4 11kW
BOX HB 125 T4 15kW
BOX HB 125 T4 18,5kW
BOX HB 125 T4 22kW
BOX HB 125 T6 3kW
BOX HB 125 T6 4kW
BOX HB 125 T6 7,5kW
BOX HB 125 T6 11kW
900
1400
1400
1400
1430
1430
900
900
910
1400
1400
1430
1430
900
910
910
1430
1430
1440
910
910
940
940
1430
1440
1440
1440
940
940
960
1440
1440
1460
1460
940
960
960
1460
1460
1465
1470
960
960
965
970
Max. Curr. (A)
230 400 690
2,85
3,48
4,74
6,31
8,06
11,7
2,13
2,85
4
4,74
6,31
8,06
11,7
2,85
4
5,5
8,06
11,7
15,2
4
5,5
6,9
9,7
11,7
15,2
6,9
9,7
12,4
9,7
12,4
16,3
12,4
16,3
-
1,65
2,01
2,75
3,65
5
6,8
1,23
1,65
2,3
2,75
3,65
5
6,8
1,65
2,3
3,2
5
6,8
8,8
2,3
3,2
4
5,6
6,8
8,8
12
15
4
5,6
7,2
12
15
20,9
27,9
5,6
7,2
9,4
20,9
27,9
33
38,5
7,2
9,4
16,1
22,4
6,9
8,6
6,9
8,6
12,02
16,04
12,02
16,04
18,98
22,14
9,26
12,88
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,55
0,75
1,1
1,5
2,2
3
0,37
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
2,2
3
4
0,75
1,1
1,5
2,2
3
4
5,5
7,5
1,5
2,2
3
5,5
7,5
11
15
2,2
3
4
11
15
18,2
22
3
4
7,5
11
10170
14080
16500
18620
21010
23430
11440
12430
13860
20570
22000
23870
27060
15400
17480
19640
29700
34980
38700
23100
25840
28600
30620
37540
44320
49370
55040
30580
35390
39910
53080
61590
66450
71510
37740
45690
51450
82600
89000
97300
103700
50000
55800
73600
88600
60
60
70
71
72
73
60
61
62
75
76
77
78
63
64
65
80
81
82
67
70
71
72
84
85
87
88
75
76
77
89
89
90
91
79
80
81
91
91
92
92
77
78
80
82
53
57
61
63
72
74
56
57
61
77
79
89
91
73
77
79
97
99
104
85
87
97
100
122
127
143
154
120
123
139
151
162
186
203
131
147
152
302
312
340
352
245
259
253
259
R.R.P. €
R.R.P. €
Polyamide Aluminium
1.006,70
938,9
975,8
994,2
1.118,60
1.174,20
919,6
1.014,30
1.089,80
1.143,50
1.241,50
1.287,40
1.313,30
1.098,40
1.229,40
1.302,90
1.377,60
1.404,60
1.509,80
1.277,50
1.329,60
1.358,40
1.464,40
1.760,00
1.809,70
2.140,30
2.240,10
1.805,40
1.856,70
1.918,40
2.339,20
2.429,20
2.811,90
2.911,80
2.072,70
2.217,70
2.426,30
5.003,70
5.123,20
5.428,60
5.605,50
4.454,80
4.654,00
5.003,70
5.140,90
1.137,50
1.061,00
1.102,60
1.123,40
1.264,00
1.326,80
1.039,20
1.146,20
1.231,40
1.292,10
1.402,80
1.454,70
1.484,00
1.241,20
1.389,30
1.472,20
1.556,70
1.587,20
1.706,10
1.443,60
1.502,40
1.535,00
1.654,80
1.988,80
2.045,00
2.418,50
2.531,30
2.040,10
2.098,10
2.167,80
2.643,30
2.745,00
3.177,40
3.290,30
2.342,20
2.506,00
2.741,70
5.654,10
5.789,20
6.134,30
6.334,20
5.034,00
5.259,00
5.654,10
5.809,20
x=1 Polyamide (BOX HB)
x=2 Aluminium (BOX HBA)
THREE PHASE RANGE 2 SPEEDS
Model
R.P.M.
max.
Max. Curr.
(A) 400V
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
BOX HB 56 T4/T8 0,85-0,20kW
BOX HB 56 T4/T8 1,40-0,30kW
BOX HB 56 T4/T8 1,80-0,40kW
BOX HB 63 T4/T8 0,85-0,20kW
BOX HB 63 T4/T8 1,40-0,30kW
BOX HB 63 T4/T8 1,80-0,40kW
BOX HB 63 T4/T8 2,20-0,60kW
BOX HB 63 T4/T8 2,80-0,70kW
BOX HB 71 T4/T8 1,40-0,30kW
BOX HB 71 T4/T8 1,80-0,40kW
BOX HB 71 T4/T8 2,20-0,60kW
BOX HB 71 T4/T8 2,80-0,70kW
BOX HB 80 T4/T8 2,20-0,60kW
BOX HB 80 T4/T8 2,80-0,70kW
BOX HB 80 T4/T8 4,00-1,00kW
BOX HB 90 T4/T8 2,80-0,70kW
BOX HB 90 T4/T8 4,00-1,00kW
BOX HB 90 T4/T8 6,50-1,80kW
BOX HB 100 T4/T8 6,50-1,80kW
BOX HB 100 T4/T8 10,0-2,50kW
BOX HB 100 T4/T8 16,0-4,50kW
1380/685
1395/705
1375/695
1380/685
1395/705
1375/695
1420/690
1420/695
1395/705
1375/695
1420/690
1420/695
1420/690
1420/695
1435/695
1420/695
1435/695
1455/720
1460/725
1450/730
1470/730
1,76/0,77
3,63/1,21
4,44/1,43
1,76/0,77
3,63/1,21
4,44/1,43
5,34/2,18
6,3/2,42
3,63/1,21
4,44/1,43
5,34/2,18
6,3/2,42
5,34/2,18
6,3/2,42
9,2/3,7
6,3/2,42
9,2/3,7
13,3/4,4
13,9/5,62
20,2/6,6
28,6/9,3
0,85/0,20
1,40/0,30
1,80/0,40
0,85/0,20
1,40/0,30
1,80/0,40
2,20/0,60
2,80/0,70
1,40/0,30
1,80/0,40
2,20/0,60
2,80/0,70
2,20/0,60
2,80/0,70
4,00/1,00
2,80/0,70
4,00/1,00
6,50/1,80
6,50/1,80
10,0/2,50
16,0/4,50
12650/6325
13970/6985
15600/7800
14080/7040
16500/8250
18620/9310
21010/10505
23430/11715
20570/10285
22000/11000
23870/11935
27060/13530
29700/14850
34980/17490
38700/19350
37540/18770
44320/22160
49370/24685
53080/26540
66450/33225
71510/35755
70/46
71/47
72/48
72/48
74/49
75/50
76/51
77/52
76/50
77/51
78/52
79/53
80/54
81/55
82/56
83/57
84/58
85/59
86/59
87/60
89/62
49
56
59
57
60
63
71
72
75
79
88
90
96
97
102
120
125
150
159
184
200
24
R.R.P. €
Polyamide
1.018,60
1.147,10
1.203,20
1.211,90
1.231,30
1.274,80
1.371,40
1.429,50
1.368,80
1.402,80
1.494,60
1.567,20
1.712,20
1.799,20
1.881,40
2.229,00
2.277,40
2.765,80
3.046,20
3.413,70
4.154,30
R.R.P. €
Aluminium
1.151,00
1.296,20
1.359,60
1.369,50
1.391,30
1.440,60
1.549,70
1.615,30
1.546,80
1.585,10
1.688,90
1.770,90
1.934,70
2.033,10
2.125,90
2.518,80
2.573,50
3.125,30
3.442,20
3.857,50
4.694,30
INLINE FANS AND ENERGY SAVING
BOX RL
Backward centrifugal in soundproof cabinet
MANUFACTURING FEATURES
• Box manufactured in galvanised steel sheet.
Soundproof cabinets with Flexiroll Pol Na 30 Anthracite grey M1 fire resistance insulated panels.
• Circular inlet and outlet
• Backward impeller, direct coupling motor.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation.
• Manufactured with standard voltages: 230/400V
50Hz in three phase motors up to 4kW, and
400/690V 50Hz for higher powers.
• Possible exchange of panels to change the air
flow sideways.
ACCESSORIES
RFS
INT
PE
BA-400
SIL-C
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Air renewal in buildings and industries.
• Maximum working temperature: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• ATEX motor fans.
• Vertical discharge.
SIL-R
JE 45
THREE PHASE RANGE
Model
R.P.M. max.
BOX RLF 400 T4/L 0,75kW
BOX RLF 400 T4/H 0,75kW
BOX RLF 450 T4 1,1kW
BOX RLF 500 T4 1,5kW
BOX RLF 500 T6 0,75kW
BOX RLF 560 T4/L 3kW
BOX RLF 560 T4/H 3kW
BOX RLF 560 T6/L 1,5kW
BOX RLF 560 T6/H 1,5kW
BOX RLF 630 T4 5,5kW
BOX RLF 630 T6 1,5kW
BOX RLF 710 T4/L 7,5kW
BOX RLF 710 T4/H 7,5kW
BOX RLF 710 T6/L 3kW
BOX RLF 710 T6/H 3kW
BOX RLF 800 T4 15kW
BOX RLF 800 T6 4kW
1400
1400
1400
1420
910
1410
1410
930
930
1450
930
1420
1420
955
955
1430
955
Max. Curr. (A)
230 400 690
3,48
4,74
6,31
4
11,7
11,7
6,9
6,9
6,9
5,54
12,4
12,4
7,45
-
2,01
2,75
3,65
2,3
6,8
6,8
4
4
12
6,9
4
3,2
15
8,6
7,2
7,2
4,3
30,59 17,68
9,35
5,37
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,75
0,75
1,1
1,5
0,75
3
3
1,5
1,5
5,5
1,5
7,5
7,5
3
3
15
4
4500
4500
5971
9000
6180
11600
12378
7750
8250
17000
11673
21500
23000
15050
16500
27900
19500
52
61
62
64
66
68
69
71
72
54
56
59
63
65
59
75
66
114
132
137
143
129
152
182
150
179
216
183
228
258
258
215
336
274
R.R.P.
€
1.655,70
1.655,70
1.894,60
2.035,00
2.160,70
2.286,50
2.392,30
2.215,50
2.447,00
2.916,80
2.588,60
3.334,70
3.459,30
3.202,20
2.886,20
4.192,40
3.251,50
THREE PHASE RANGE 2 SPEEDS
Model
BOX RLF 400/H T4/T8 0,75-0,15kW
BOX RLF 450 T4/T8 1,1-0,18kW
BOX RLF 500 T4/T8 1,5-0,25kW
BOX RLF 560/H T4/T8 3-0,55kW
BOX RLF 630 T4/T8 5,5-1,1kW
BOX RLF 710/H T4/T8 7,5-1,5kW
R.P.M. max.
Max. Curr. (A)
400V
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1380/685
1370/695
1375/700
1400/700
1455/720
1455/720
2,33/0,88
2,33/0,88
4,44/1,43
6,3/2,42
10,2/3,09
13,9/5,62
0,7-0,15
1-0,22
1,5-0,35
2,5-0,65
4,7-1,1
6,4-1,4
3950/2000
5971/2980
8250/4125
12275/6150
16300/8150
23623/11810
80/57
58/47
61/49
64/51
66/53
68/54
132
137
143
182
216
258
R.R.P.
€
1.911,70
2.140,70
2.301,00
2.738,80
3.560,10
4.153,20
25
INLINE FANS AND ENERGY SAVING
BOX BD
BOX BD CLEAN AIR Centrifugal in soundproof cabinet, CA models with G4 filter
MANUFACTURING FEATURES
• Impellers made of polyamide reinforced with fiberglass up to size 12/12. Other models made of
galvanised steel sheet.
• BD range fans assembled in soundproof cabinets
with Flexiroll Pol Na 30 anthracite grey M1 fire resistance insulated panels.
• Fan assembled on antivibration mountings.
• Connection gland included.
• Equipped with inlet deflector wing, minimizing turbulence and optimizing efficiency.
• Closed motors specially designed by Casals. Extruded aluminium motor housing. Totally enclosed
wiring box IP-65. IP-54 motor protection and rated
class F insulation. Standard voltages 230V 50 Hz
for single phase and 230/400V 50Hz.
• Clean air: BD fans with integrated G4 filter (particles 10μm performance 94%). Removable filter
frame from both sides of the box for better maintenance. Replaceable and washable filtering foam.
BOX BD
Optimized suctioning air inlet to maximize the fan
performance.
APPLICATIONS
Designed for inline installation, indoor or outdoor
assembly, they are suitable for:
• Air renewal in buildings and industries.
• Industrial and professional kitchen hoods.
• Maximum working temperature: 50ºC.
UNDER REQUEST
• 3 speed fans.
• Vertical discharge, circular inlet and outlet, blind
cover.
• LG0 position.
BOX BD CLEAN AIR
ACCESSORIES
REG
RFS
INT
PE
PI
VIS
TCA
TIAC
JE 45
SINGLE PHASE RANGE
Model
BOX BD / CLEAN AIR
BOX BD 7/7 M4 0,15kW
BOX BD 7/7 M6 0,08kW
BOX BD 9/9 M4 0,37kW
BOX BD 9/9 M4 0,55kW
BOX BD 9/9 M6 0,15kW
BOX BD 9/9 M6 0,25kW
BOX BD 10/10 M4 0,55kW
BOX BD 10/10 M6 0,25kW
BOX BD 10/10 M6 0,37kW
BOX BD 12/12 M6 0,55kW
BOX BD 12/12 M6 0,75kW
BOX BD 12/12 M6 1,1kW
Equivalence
(cm)
R.P.M. max.
19/19
19/19
25/25
25/25
25/25
25/25
28/28
28/28
28/28
33/33
33/33
33/33
1300
860
1350
1350
850
900
1350
900
890
860
840
860
Max. Curr. (A)
230
400
1,85
1,03
2,83
4,86
1,69
2,33
4,86
2,33
3,33
4,93
6,86
9,26
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
0,15
0,08
0,37
0,55
0,15
0,25
0,55
0,25
0,37
0,55
0,75
1,1
1400
1400
3200
3300
2530
2620
3690
3230
3710
5590
6250
7200
50
50
54
55
50
52
56
54
54
57
57
59
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
1,1
2,2
7200
10800
58
67
R.R.P. €
BOX BD
343,50
343,50
416,10
420,70
406,30
414,80
452,80
440,40
444,60
590,60
603,10
659,40
R.R.P. €
BOX BD CA
425,30
425,30
504,50
509,10
494,70
503,20
547,80
535,30
539,60
692,10
704,60
760,90
THREE PHASE RANGE
Model
BOX BD / CLEAN AIR
BOX BD 12/12 T6 1,1kW
BOX BD 15/15 T6 2,2kW
26
Equivalence
(cm)
R.P.M. max.
33/33
39/39
960
900
Max. Curr. (A)
230
400
6,54
10,92
3,78
6,31
R.R.P. €
BOX BD
618,50
998,00
R.R.P. €
BOX BD CA
720,00
1.156,40
INLINE FANS AND ENERGY SAVING
BOX BV
BOX BV CLEAN AIR Belt driven centrifugal in soundproof cabinet, CA models with G4 filter
MANUFACTURING FEATURES
• Impellers made of polyamide reinforced with fiberglass up to size 12/12. Other models are made
of galvanised steel sheet.
• BV, BVC, BVCR range fans assembled in soundproof cabinets with Flexiroll Pol Na 30 Anthracite
grey or fiberglass (big sizes), M1 fire resistance insulated panels.
• Fan assembled on antivibration mountings.
• Supplied with motor, pulleys and belts.
• Connection gland included.
• Equipped with inlet deflector wing, minimizing
the turbulence and optimizing the efficiency.
• Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230/400V 50Hz for three phase, motors up to 4kW and 400/690V 50Hz for higher
powers.
BOX BV
CLEAN AIR
• BV fans with integrated G4 filter (particles 10μm
performance 94%). Removable filter frame from
both sides of the box for better maintenance. Replaceable and washable filtering foam. Optimized
suctioning air inlet to maximize the fan performance.
APPLICATIONS
Designed for inline installation, indoor or outdoor
assembly, they are suitable for:
• Air renewal in buildings and industries.
• Industrial and professional kitchen hoods.
• Maximum working temperature: 60ºC.
CLEAN AIR:
• Contributes to a cleaner free of particles air.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 SPEED MOTORS.
• Vertical discharge, circular inlet and outlet, blind
cover.
• Transmission ratio variation.
• LG0 position.
BOX BV CLEAN AIR
ACCESSORIES
RFS
INT
PE
PI
VIS
TCA
TIAC
JE 45
27
INLINE FANS AND ENERGY SAVING
THREE PHASE RANGE
Max. Curr. (A)
Model
BOX BV/ CLEAN AIR
Equivalence
(cm)
R.P.M.
max.
230
400
690
BOX BV 7/7 0,18kW
BOX BV 7/7 0,25kW
BOX BV 7/7 0,37kW
BOX BV 7/7 0,55kW
BOX BV 7/7 0,75kW
BOX BV 9/9 0,37kW
BOX BV 9/9 0,55kW
BOX BV 9/9 0,75kW
BOX BV 9/9 1,1kW
BOX BV 10/10 0,37kW
BOX BV 10/10 0,55kW
BOX BV 10/10 0,75kW
BOX BV 10/10 1,1kW
BOX BV 10/10 1,5kW
BOX BV 12/12 0,37kW
BOX BV 12/12 0,55kW
BOX BV 12/12 0,75kW
BOX BV 12/12 1,1kW
BOX BV 12/12 1,5kW
BOX BV 12/12 2,2kW
BOX BV 15/15 0,55kW
BOX BV 15/15 0,75kW
BOX BV 15/15 1,1kW
BOX BV 15/15 1,5kW
BOX BV 15/15 2,2kW
BOX BV 15/15 3kW
BOX BV 15/15 4kW
BOX BV 18/18 1,1kW
BOX BV 18/18 1,5kW
BOX BV 18/18 2,2kW
BOX BV 18/18 3kW
BOX BV 18/18 4kW
BOX BV 18/18 5,5kW
BOX BV 20/20 1,5kW
BOX BV 20/20 2,2kW
BOX BV 20/20 3kW
BOX BV 20/20 4kW
BOX BV 20/20 5,5kW
BOX BV 20/20 7,5kW
BOX BV 22/22 1,5kW
BOX BV 22/22 2,2kW
BOX BV 22/22 3kW
BOX BV 22/22 4kW
BOX BV 22/22 5,5kW
BOX BV 22/22 7,5kW
BOX BV 22/22 11kW
BOX BV 25/25 2,2kW
BOX BV 25/25 3kW
BOX BV 25/25 4kW
BOX BV 25/25 5,5kW
BOX BV 25/25 7,5kW
BOX BV 25/25 11kW
BOX BV 30/28 2,2kW
BOX BV 30/28 3kW
BOX BV 30/28 4kW
BOX BV 30/28 5,5kW
BOX BV 30/28 7,5kW
BOX BV 30/28 11kW
BOX BV 30/28 15kW
19/19
19/19
19/19
19/19
19/19
25/25
25/25
25/25
25/25
28/28
28/28
28/28
28/28
28/28
33/33
33/33
33/33
33/33
33/33
33/33
39/39
39/39
39/39
39/39
39/39
39/39
39/39
47/47
47/47
47/47
47/47
47/47
47/47
51/51
51/51
51/51
51/51
51/51
51/51
56/56
56/56
56/56
56/56
56/56
56/56
56/56
63/63
63/63
63/63
63/63
63/63
63/63
76/71
76/71
76/71
76/71
76/71
76/71
76/71
1000
1100
1200
1400
1600
900
1000
1200
1300
700
800
900
1000
1200
600
700
800
900
1000
1100
500
600
600
700
800
900
1000
500
500
600
600
700
800
450
500
600
600
700
750
400
400
500
500
600
600
700
350
400
450
450
550
600
250
250
300
350
400
450
450
1,12
1,44
1,94
2,69
3,48
1,94
2,69
3,48
4,74
1,94
2,69
3,48
4,74
6,31
1,94
2,69
3,48
4,74
6,31
8,06
2,69
3,48
4,74
6,31
8,06
11,7
15,2
4,74
6,31
8,06
11,7
15,2
6,31
8,06
11,7
15,2
6,31
8,06
11,7
15,2
8,06
11,7
15,2
8,06
11,7
15,2
-
0,65
0,83
1,12
1,56
2,01
1,12
1,56
2,01
2,75
1,12
1,56
2,01
2,75
3,65
1,12
1,56
2,01
2,75
3,65
5
1,56
2,01
2,75
3,65
5
6,8
8,8
2,75
3,65
5
6,8
8,8
12
3,65
5
6,8
8,8
12
15
3,65
5
6,8
8,8
12
15
20,9
5
6,8
8,8
12
15
20,9
5
6,8
8,8
12
15
20,9
27,9
6,9
6,9
8,6
6,9
8,6
12,02
6,9
8,6
12,02
6,9
8,6
12,02
16,04
28
Rated
Power
kW
0,18
0,25
0,37
0,55
0,75
0,37
0,55
0,75
1,1
0,37
0,55
0,75
1,1
1,5
0,37
0,55
0,75
1,1
1,5
2,2
0,55
0,75
1,1
1,5
2,2
3
4
1,1
1,5
2,2
3
4
5,5
1,5
2,2
3
4
5,5
7,5
1,5
2,2
3
4
5,5
7,5
11
2,2
3
4
5,5
7,5
11
2,2
3
4
5,5
7,5
11
15
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1550
1700
1875
2175
2450
2600
3000
3400
3800
3500
4000
4500
5000
5500
4500
5250
5750
6500
7400
8000
6400
7000
8000
8800
10000
11100
12400
10500
11800
13500
15000
16500
18100
13000
14500
16000
18000
20000
22000
15500
18000
20000
22000
24000
26500
30700
21500
23000
25800
28200
31500
36000
27500
31000
34000
37500
42500
47500
54000
62
64
66
69
72
70
73
77
80
68
70
73
77
80
64
67
70
73
76
79
62
64
67
70
74
77
80
67
72
74
77
79
84
74
76
77
80
82
82
73
76
79
82
85
87
90
72
75
77
81
85
88
73
76
77
81
83
86
88
37
37,8
39
41
42,5
51,5
54,5
56
59
55
57
58,5
61,3
64,6
69
71
72,4
75,3
78,6
87
85
86,4
89,3
92,6
101
103
108
122
125,3
133,7
135,7
141
154,5
222
230,5
232,5
237,5
251,5
251,5
250
257
261
265
279
290
316
297
299
304
318
329
349
380
382
387
402
415
426
449
R.R.P. €
BOX BV
587,70
605,90
614,80
633,50
677,50
671,30
689,80
743,00
775,70
707,30
725,70
765,90
792,40
833,00
818,20
828,10
851,30
901,40
945,60
996,70
1.117,00
1.175,10
1.207,50
1.294,50
1.353,40
1.387,80
1.453,90
1.493,20
1.520,00
1.567,20
1.602,20
1.668,00
1.841,10
3.049,80
3.259,30
3.367,40
3.501,50
3.860,10
4.115,50
3.281,00
3.516,70
3.603,50
3.737,60
4.108,50
4.490,40
4.929,20
3.976,00
4.074,20
4.252,10
4.603,60
4.952,20
5.635,50
4.368,90
4.560,80
5.068,10
5.285,80
5.431,90
6.342,10
6.888,90
R.R.P. €
BOX BV CA
667,20
685,30
694,30
713,00
759,20
757,30
775,70
831,40
864,20
799,40
817,70
861,00
887,30
928,00
916,80
926,50
952,70
1.002,80
1.047,10
1.098,10
1.225,10
1.289,70
1.322,10
1.409,10
1.468,10
1.502,40
1.568,50
1.620,80
1.647,80
1.695,00
1.729,90
1.795,70
1.968,70
-
INLINE FANS AND ENERGY SAVING
BOX BST
Belt driven centrifugal in soundproof cabinet
MANUFACTURING FEATURES
• B ST range fans assembled in soundproofing
cabinets.
• Fan assembled on antivibration mountings.
• Supplied with motor, pulleys and belts.
• Interchangeable panels to allow different fan positions.
• Connection gland included.
• Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard
voltages 230/400V 50 Hz for three phase, motors
up to 4kW and 400/690V 50Hz for higher powers.
ACCESSORIES
RFS
INT
PE
APPLICATIONS
Designed for inline installation, indoor or outdoor
assembly, they are suitable for:
• Air renewal in buildings and industries.
• Industrial and professional kitchen hoods.
• Maximum working temperature: 80ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Vertical discharge, circular pipes and blind cover.
JE 45
29
INLINE FANS AND ENERGY SAVING
THREE PHASE RANGE
Model
BOX BST 9/4 0,18kW
BOX BST 9/4 0,25kW
BOX BST 9/4 0,37kW
BOX BST 9/4 0,55kW
BOX BST 9/4 0,75kW
BOX BST 10/5 0,37kW
BOX BST 10/5 0,55kW
BOX BST 10/5 0,75kW
BOX BST 10/5 1,1kW
BOX BST 10/5 1,5kW
BOX BST 12/6 0,37kW
BOX BST 12/6 0,55kW
BOX BST 12/6 0,75kW
BOX BST 12/6 1,1kW
BOX BST 12/6 1,5kW
BOX BST 12/6 2,2kW
BOX BST 15/7 0,55kW
BOX BST 15/7 0,75kW
BOX BST 15/7 1,1kW
BOX BST 15/7 1,5kW
BOX BST 15/7 2,2kW
BOX BST 15/7 3kW
BOX BST 15/7 4kW
BOX BST 18/9 1,1kW
BOX BST 18/9 1,5kW
BOX BST 18/9 2,2kW
BOX BST 18/9 3kW
BOX BST 18/9 4kW
BOX BST 18/9 5,5kW
BOX BST 20/10 1,5kW
BOX BST 20/10 2,2kW
BOX BST 20/10 3kW
BOX BST 20/10 4kW
BOX BST 20/10 5,5kW
BOX BST 20/10 7,5kW
BOX BST 22/11 1,5kW
BOX BST 22/11 2,2kW
BOX BST 22/11 3kW
BOX BST 22/11 4kW
BOX BST 22/11 5,5kW
BOX BST 22/11 7,5kW
BOX BST 22/11 11kW
BOX BST 25/13 2,2kW
BOX BST 25/13 3kW
BOX BST 25/13 4kW
BOX BST 25/13 5,5kW
BOX BST 25/13 7,5kW
BOX BST 25/13 11kW
BOX BST 30/14 2,2kW
BOX BST 30/14 3kW
BOX BST 30/14 4kW
BOX BST 30/14 5,5kW
BOX BST 30/14 7,5kW
BOX BST 30/14 11kW
BOX BST 30/14 15kW
30
Max. Curr. (A)
230
400
690
0,73
1,4
2,1
2,45
3,66
1,94
2,69
3,48
4,74
6,31
2,1
2,45
3,66
4,65
5,79
8,26
2,45
3,66
4,65
5,79
8,26
13,2
15,2
4,74
6,31
8,06
11,7
15,2
6,31
8,06
11,7
15,2
6,31
8,06
11,7
15,2
8,06
11,7
15,2
8,06
11,7
15,2
-
0,42
0,81
1,2
1,42
2,12
1,12
1,56
2,01
2,75
3,65
1,2
1,42
2,12
2,69
3,73
4,78
1,42
2,12
2,69
3,73
4,78
7,65
8,8
2,75
3,65
5
6,8
8,8
12
3,65
5
6,8
8,8
12
15
3,65
5
6,8
8,8
12
15
20,9
5
6,8
8,8
12
15
20,9
5
6,8
8,8
12
15
20,9
27,9
6,9
6,9
8,6
6,9
8,6
12,02
6,9
8,6
12,02
6,9
8,6
12,02
16,04
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,18
0,25
0,37
0,55
0,75
0,37
0,55
0,75
1,1
1,5
0,37
0,55
0,75
1,1
1,5
2,2
0,55
0,75
1,1
1,5
2,2
3
4
1,1
1,5
2,2
3
4
5,5
1,5
2,2
3
4
5,5
7,5
1,5
2,2
3
4
5,5
7,5
11
2,2
3
4
5,5
7,5
11
2,2
3
4
5,5
7,5
11
15
1500
1700
1900
2000
2400
2400
2800
3200
3700
3900
2500
2900
3300
3900
4200
4800
3600
4800
6000
6500
7800
8500
9500
5000
6000
7500
8000
9000
10000
11000
13000
14000
15000
16500
19000
11000
15000
16000
18000
20000
22000
23000
16500
19000
21000
24000
26000
29000
16000
18000
22000
25000
30000
33000
36000
72
75
78
80
85
68
74
72
76
82
84
87
82
83
87
88
89
92
79
83
86
88
92
94
77
79
82
85
87
92
71
74
76
78
83
86
74
76
78
82
85
87
45
46
48
50
52
58
59
60
62
63
72
73
74
77
80
85
91
92
95
98
103
106
109
110
114
119
122
125
140
203
208
211
214
227
235
214
219
222
225
238
246
273
251
254
257
270
278
305
325
328
331
344
352
379
398
R.R.P.
€
876,90
879,20
906,80
943,80
975,50
970,00
1.008,00
1.040,10
1.120,80
1.214,30
1.066,10
1.105,10
1.136,20
1.223,90
1.299,70
1.370,80
1.215,60
1.253,90
1.341,00
1.428,80
1.523,20
1.634,90
1.894,80
1.531,40
1.611,10
1.727,00
1.824,90
2.104,10
2.466,60
2.424,20
2.514,50
2.629,70
2.863,50
3.205,70
3.591,70
2.572,50
2.714,30
2.780,70
3.082,60
3.379,30
3.746,30
4.496,70
2.864,20
3.018,70
3.280,80
3.581,70
3.931,30
4.718,10
3.344,60
3.452,20
3.714,30
4.015,20
4.483,50
5.242,90
5.807,20
INLINE FANS AND ENERGY SAVING
BOX BSTB
Belt driven backward centrifugal in soundproof cabinet
MANUFACTURING FEATURES
• BSTB range fans assembled in soundproof cabinets with insulated panels
• Fan assembled on antivibration mountings.
• Supplied with motor, pulleys and belts.
• Connection gland included.
• Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230/400V 50Hz for three phase, motors up to 4kW and 400/690V 50Hz for higher
powers.
• Industrial and professional kitchen hoods.
• Maximum working temperature: 80ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Inlet in the opposite side, vertical inlet, blind inlet
panel.
• Transmission ratio variation.
• Sandwich insulation.
APPLICATIONS
Designed for inline installation, indoor or outdoor
assembly, they are suitable for:
• Air renewal in buildings and industries.
JE 45
ACCESSORIES
Model
BOX BSTB 355 0,37kW
BOX BSTB 355 0,55kW
BOX BSTB 355 0,75kW
BOX BSTB 355 1,1kW
BOX BSTB 355 1,5kW
BOX BSTB 355 2,2kW
BOX BSTB 355 3kW
BOX BSTB 400 0,55kW
BOX BSTB 400 0,75kW
BOX BSTB 400 1,1kW
BOX BSTB 400 1,5kW
BOX BSTB 400 2,2kW
BOX BSTB 400 3kW
BOX BSTB 400 4kW
BOX BSTB 450 0,75kW
BOX BSTB 450 1,1kW
BOX BSTB 450 1,5kW
BOX BSTB 450 2,2kW
BOX BSTB 450 3kW
BOX BSTB 450 4kW
BOX BSTB 450 5,5kW
BOX BSTB 450 7,5kW
BOX BSTB 500 1,1kW
BOX BSTB 500 1,5kW
BOX BSTB 500 2,2kW
BOX BSTB 500 3kW
BOX BSTB 500 4kW
BOX BSTB 500 5,5kW
BOX BSTB 500 7,5kW
BOX BSTB 560 1,5kW
BOX BSTB 560 2,2kW
BOX BSTB 560 3kW
BOX BSTB 560 4kW
BOX BSTB 560 5,5kW
BOX BSTB 560 7,5kW
BOX BSTB 560 11kW
BOX BSTB 630 2,2kW
BOX BSTB 630 3kW
BOX BSTB 630 4kW
BOX BSTB 630 5,5kW
BOX BSTB 630 7,5kW
BOX BSTB 630 11kW
BOX BSTB 630 15kW
RFS
INT
PE
JE-45
230
Max. Curr. (A)
400
690
Rated Power
kW
Air flow
m3/h
1,94
2,69
3,48
4,74
6,31
8,06
11,7
2,69
3,48
4,74
6,31
8,06
11,7
15,2
3,48
4,74
6,31
8,06
11,7
15,2
4,74
6,31
8,06
11,7
15,2
6,31
8,06
11,7
15,2
8,06
11,7
15,2
-
1,12
1,56
2,01
2,75
3,65
5
6,8
1,56
2,01
2,75
3,65
5
6,8
8,8
2,01
2,75
3,65
5
6,8
8,8
12
15
2,75
3,65
5
6,8
8,8
12
15
3,65
5
6,8
8,8
12
15
20,9
5
6,8
8,8
12
15
20,9
27,9
6,9
8,6
6,9
8,6
6,9
8,6
12,02
6,9
8,6
12,02
16,04
0,37
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
1,5
2,2
3
4
0,75
1,1
1,5
2,2
3
4
5,5
7,5
1,1
1,5
2,2
3
4
5,5
7,5
1,5
2,2
3
4
5,5
7,5
11
2,2
3
4
5,5
7,5
11
15
3370
3850
4330
5050
5530
6010
6980
4350
5020
5360
6030
7370
8040
9460
5990
6490
7490
8490
9490
10490
11490
12980
7490
8850
9530
10890
12260
13620
14980
9550
11290
12160
13020
14760
16500
18230
12720
13990
15260
16540
19080
21630
22900
R.R.P.
€
1.696,30
1.724,90
1.741,60
1.745,20
1.797,90
1.827,00
1.850,60
1.897,20
1.908,80
1.915,30
1.961,30
1.998,60
2.029,30
2.095,60
2.173,80
2.179,30
2.226,30
2.248,20
2.296,00
2.355,80
2.511,00
2.674,80
2.489,80
2.539,90
2.558,80
2.604,70
2.663,50
2.817,60
3.001,50
3.239,20
3.216,80
3.279,10
3.411,30
3.368,80
3.707,90
3.899,50
3.583,10
3.673,70
3.779,60
3.742,00
3.417,10
4.304,40
4.598,60
31
INLINE FANS AND ENERGY SAVING
Model
BOX BSTB 710 3kW
BOX BSTB 710 4kW
BOX BSTB 710 5,5kW
BOX BSTB 710 7,5kW
BOX BSTB 710 11kW
BOX BSTB 710 15kW
BOX BSTB 710 18,5kW
BT
230
Max. Curr. (A)
400
690
Rated Power
kW
Air flow
m3/h
11,7
15,2
-
6,8
8,8
12
15
20,9
27,9
33
6,9
8,6
12,02
16,04
18,98
3
4
5,5
7,5
11
15
18,5
18370
18370
20200
22960
25710
27550
31220
R.R.P.
€
4.673,90
4.788,10
4.730,50
4.946,50
5.317,80
5.588,60
5.881,20
Backward centrifugal, external rotor motor
MANUFACTURING FEATURES
• Galvanised steel sheet housing.
• Galvanised steel impeller.
• External wiring box.
• Asynchronous external rotor, IP-44 protection
and rated class B insulation according to the DIN
40.050 h1 Standard and ball bearings permanently greased. Manufactured with standard voltages
230V 50Hz.
ACCESSORIES
REG
INT
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Air renewal in bathrooms and small closed environments.
• Maximum working temperature: 50ºC.
PE
SINGLE PHASE RANGE
Code
250070103
250080103
250090103
250090120
250100103
250120103
250110103
32
Model
BT 100
BT 125
BT 150
BT 160
BT 200
BT 250
BT 315
R.P.M. max.
Max. Curr. (A)
230
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
2.420
2.420
2.450
2.520
2.550
2.600
2.650
0,35
0,42
0,43
0,60
0,81
0,85
0,80
0,08
0,09
0,09
0,12
0,18
0,19
0,19
240
350
450
660
1.000
1.180
1.500
46
48
48
49
52
56
56
2,6
3
3,2
4,4
4,9
4,2
6
R.R.P.
€
109,40
119,00
131,50
137,50
171,20
179,50
235,00
INLINE FANS AND ENERGY SAVING
BT-ILF
Mixflow, polypropylene casing and impeller
MANUFACTURING FEATURES
• Housing and turbine made of plastic.
• External wiring box.
• Standard voltages 230V 50Hz.
• Range specially designed to allow fan assembly
and disassembly with no need to manage ducts.
UNDER REQUEST
•BT-ILF TIMER models.
APPLICATIONS
Designed for inline installation, they are suitable for:
• Air renewal in bathrooms and small closed environments.
• Maximum working temperature: 50ºC.
BT-ILF 100
BT-ILF 4-8
ACCESSORIES
REG
INT
PE
SINGLE PHASE RANGE
Model
BT-ILF 100
BT-ILF 4
BT-ILF 5
BT-ILF 6
BT-ILF 8
Max. Curr. (A)
230
400
R.P.M. max.
2200
2300/1700
2300/1700
2700/2000
2700/2000/1800
KBD-KHB-KTE
0,16
0,18/0,10
0,18/0,10
0,36/0,27
0,34/0,27/0,24
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Diameter
(mm)
Weight
Kg
0,025
0,03/0,018
0,03/0,018
0,08/0,06
0,085/0,065/0,055
130
270/190
365/250
595/420
910/820/720
24
30/24
32/26
33/27
39/34/32
100
100
125
150
200
1,2
2,1
2,1
3,2
4,5
R.R.P.
€
74,60
88,00
118,40
156,10
215,30
Staircase pressurisation kit
Set consisting of a differential pressure transmitter (DPS) with a frequency speed controller (RFS), and a
supplying unit (Box BD, Box HB or HMTE IMP). Used to pressurize staircases and escape routes. It automatically regulates the airflow to keep a 50 Pa differential pressure, according to the UNE-EN 12101-6
standard.
THREE PHASE RANGE
Model
KBD
KHB-1
KHB-2
KHB-3
KTE-1
KTE-2
Differential pressure transmitter
Frequency speed
controller
Ventilation unit
Air flow
m3/h
Sound
dB (A)
DPS
DPS
DPS
DPS
DPS
DPS
RFS 2-2
RFS 2-1/2
RFS 2-1
RFS 2-2
RFS 2-1
RFS 2-2
BOX BD 12/12 T6 1,1kW
BOX HB 45 T4 0,37kW
BOX HB 56 T4 0,75kW
BOX HB 63 T4 1,1kW
HMTE IMP 56 T4 0,55kW
HMTE IMP 63 T4 1,1kW
6750
7500
11800
15800
9000
12300
58
67
70
71
72
74
R.R.P.
€
1.401,90
984,30
1.105,50
1.320,50
1.889,40
2.297,30
33
ENERGY SAVING
CMV
Controlled Mechanical Ventilation
EAA
Self-regulable air inlet. Diffuser and external cover on the facade
included.
Model
R.R.P. €
EAA 15
EAA 22
EAA 30
EAA 45
5,80
5,80
5,80
6,20
EAA S
Acoustic and self-regulated air inlet with diffuser, external cover on
the facade and noise attenuator accessory included.
Model
R.R.P. €
EAA S 22
EAA S 30
EAA S 45
26,10
26,10
28,60
EAA SH
Acoustic and moisture-regulated air inlet. Air-flow from 7 to 40 m3/h
depending on the degree of humidity. Diffuser, external cover on the
facade and noise attenuator accessory included.
Model
R.R.P. €
EAA SH 40
69,00
BEA S / BEA C
Self-regulated extraction inlet that allows a constant extraction of air.
BEA S provides a fixed air-flow extraction, suitable for bathrooms.
BEA C provides a permanent air-flow extraction that adds an additional aif-flow with external action; suitable for kitchens and small
environments.
Model
BEA S 15
BEA S 30
BEA S 45
BEA S 60
BEA S 75
BEA S 90
BEA S 120
BEA S 150
BEA C 20/75
BEA C 30/90
BEA C 45/105
BEA C 45/120
BEA C 45/135
MGJ 125 (hose)
MGP 125 (hose)
MGP 125/80 (hose)
Model
R.R.P. €
BE 80
BE 125
8,50
11,00
BIRM
Manual self-regulated extraction inlet through a central screw. Manufactured in painted steel sheet. Suitable for community housing.
BEH 5/40
BEH 5/45
BEH 10/40
BEH 14/45
BEH 15/100
BEH 15/50
BEH 15/75
BIRM 100
BIRM 125
BIRM 160
BIRM 200
R.R.P. €
10,60
13,10
16,50
23,60
BERM
Manual self-regulated extraction inlet through a central screw. Manufactured in painted steel sheet. Suitable for community housing.
Model
BERM 100
BERM 125
BERM 160
BERM 200
34
R.R.P. €
22,90
27,60
34,00
44,20
R.R.P €
77,50
77,50
77,50
77,50
88,40
83,90
86,80
BEIRM
Manual self-regulated extraction inlet through a central screw. Manufactured in plastic. Suitable for community housing.
Model
Model
15,90
15,90
15,90
15,90
15,90
15,90
29,90
29,90
31,70
31,70
31,70
31,70
31,70
4,70
7,00
7,00
BEH
Moisture-regulated extraction air inlet.
Model
BE
Plastic extraction inlet for houses.
R.R.P €
BEIRM 80
BEIRM 100
BEIRM 125
BEIRM 160
BEIRM 200
R.R.P. €
11,60
15,20
16,00
22,30
29,90
ENERGY SAVING
CFR
Circular constant flow regulator with hose and self-regulating system composed of a hatch and a regulatory
spring that allows a constant flow rate with pressure variations between 50 and 200 Pa.
Model
CFR 80/15
CFR 80/30
CFR 80/45
CFR 100/15
CFR 100/30
CFR 100/45
CFR 100/60
CFR 100/75
CFR 100/90
CFR 125/15
CFR 125/30
CFR 125/45
CFR 125/60
CFR 125/75
CFR 125/90
CFR 125/120
CFR 125/150
CFR 125/180
CFR 160/120
CFR 160/150
R.R.P. €
Model
16,40
16,40
16,40
19,90
19,90
19,90
19,90
19,90
19,90
22,50
22,50
22,50
22,50
22,50
22,50
22,50
22,50
22,50
36,10
36,10
CFR 160/180
CFR 160/210
CFR 160/240
CFR 160/270
CFR 160/300
CFR 200/210
CFR 200/240
CFR 200/270
CFR 200/300
CFR 200/350
CFR 200/400
CFR 200/450
CFR 200/500
CFR 250/350
CFR 250/500
CFR 250/550
CFR 250/600
CFR 250/650
CFR 250/700
R.R.P. €
36,10
36,10
36,10
36,10
36,10
50,20
50,20
50,20
50,20
50,20
50,20
50,20
50,20
64,90
64,90
64,90
64,90
64,90
64,90
OKTOPUS
CMV extraction box.
Model
OKTOPUS
R.R.P. €
144,30
BOX SIRIUS
400ºC 1/2h CMV box suitable for community housings and small environments from the tertiary sector.
Model
BOX SIRIUS 600
BOX SIRIUS 1200
R.R.P. €
595,50
751,20
BOX ANTARES
400ºC 1/2h CMV direct driven box.
Model
BOX ANTARES 2200
BOX ANTARES 2200 IN
R.R.P. €
1.288,30
1.327,20
BOX VEGA BP
400ºC 1/2h CMV box suitable for community housings and small environments from the tertiary sector. Quick
release system.
Model
BOX VEGA BP 3400
BOX VEGA BP 4500
BOX VEGA BP 7500
BOX VEGA BP 9800
BOX VEGA BP 3400 IN
BOX VEGA BP 4500 IN
BOX VEGA BP 7500 IN
BOX VEGA BP 9800 IN
R.R.P. €
1.434,80
1.733,70
2.042,90
2.474,60
1.631,80
2.007,40
2.318,90
2.693,30
35
ENERGY SAVING
RCIB
Heat recovery unit
MANUFACTURING FEATURES
• Chassis: extruded anodized aluminum profiles
with reinforced corners made of polyamide.
• Casing: detachable sandwich panels. Outside
lateral panel steel with white lacquered coating,
25 mm thickness rock wool (Fire M0), thermal and
acoustic insulation, and inside panel made of galvanized steel.
• Fixing system through threaded fittings on the
structure profiles.
• Fans: double inlet centrifugal fans with forward
impeller and direct belt-driven motor. Mounted and
fixed to the outlet panels for an easy access wiring
operations and maintenance.
• Exchanger: Eurovent certified crossed flow exchanger cell made of aluminium, removable from
the bottom and top panels.
• Efficiency up to 60% depending on the models
and conditions of use.
• Condensates tray: Condensates tray in galvanized steel with a plastic drain outside.
• Filters: Two filtration levels with low pressure drop
filters G4 + F7 in outlet and return (F7 + F9 option
in outlet) mounted on slides horizontally or vertically removable inspection door from the side, top
or bottom.
• Motorization: four speed 230v/50Hz II motor in
RCIB 600 and RCIB 900 models. Three speed motor
in RCIB 1900 and RCIB 2800 models. 400V/50Hz
III motor in RCIB 3700 and RCIB 2800 models.
ACCESSORIES
FILTERS
INT
INT 3V
APPLICATIONS
Energy recovery units for ventilation installations according to the EN-13779 requirements.
Advantages:
• It reduces the consumption with a thermal recovery efficiency up to 60%
• Easy accessibility and maintenance of components.
• Double-panel structure with M0 25mm rock wool
insulation.
• Two filtration levels: G4 + F7 in outlet and return.
• Safety switch and deportable connection box.
UNDER REQUEST
• Partial exterior motorizable bypass.
• Heat electrical coil with heat resistors with dissipation fins. 230VII
supply, with double thermal protection with automatic reset at 75°C, and manual reset at a 115°C.
• Hot water coil with copper tubes and aluminum
fins. Supplied with no-freeze safety thermostat with
automatic reset at adjustable temperature.
• Sandwich panels with 50mm thickness M0 insulation.
DPS
SINGLE PHASE RANGE
Code
300727800
300727900
300728000
300728100
-
36
Model
RCIB H 600
RCIB H 900
RCIB H 1900
RCIB H 2800
RCIB H 600 BP
RCIB H 900 BP
RCIB H 1900 BP
RCIB H 2800 BP
RCIB V 600
RCIB V 900
RCIB V 1900
RCIB V 2800
RCIB V 600 BP
RCIB V 900 BP
RCIB V 1900 BP
RCIB V 2800 BP
RCIB WC H 600
RCIB WC H 900
RCIB WC H 1900
RCIB WC H 2800
RCIB EC H 600
RCIB EC H 900
Absorbed Max.
Current (A)
Motor
power W
Motor
polarity
Air flow
m3/h
Sound
dB (A)
Insulation
class
Protection
index
Weight
Kg
2 x 0,86
2 x 1,55
2 x 2,8
2 x 4,7
2 x 0,86
2 x 1,55
2 x 2,8
2 x 4,7
2 x 0,86
2 x 1,55
2 x 2,8
2 x 4,7
2 x 0,86
2 x 1,55
2 x 2,8
2 x 4,7
2 x 0,86
2 x 1,55
2 x 2,8
2 x 4,7
2 x 0,86
2 x 1,55
2 x 195
2 x 355
2 x 375
2 x 550
2 x 195
2 x 355
2 x 375
2 x 550
2 x 195
2 x 355
2 x 375
2 x 550
2 x 195
2 x 355
2 x 375
2 x 550
2 x 195
2 x 355
2 x 375
2 x 550
2 x 195
2 x 355
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
590
890
1890
2800
590
890
1890
2800
590
890
1890
2800
590
890
1890
2800
590
890
1890
2800
590
890
50
52
53
56
50
52
53
56
50
52
53
56
50
52
53
56
50
52
53
56
50
52
F
F
B
F
F
F
B
F
F
F
B
F
F
F
B
F
F
F
B
F
F
F
20
20
44
44
20
20
44
44
20
20
44
44
20
20
44
44
20
20
44
44
20
20
34
70
130
150
34
70
130
150
34
70
130
150
34
70
130
150
34
70
130
150
34
70
R.R.P.
€
2.643,40
2.941,20
3.783,60
5.128,50
2.904,00
3.206,50
4.058,20
5.431,00
2.806,30
3.122,70
4.007,00
5.445,00
3.085,50
3.406,60
4.304,80
5.770,80
3.262,30
3.509,00
4.518,90
5.915,00
2.810,90
3.141,30
ENERGY SAVING
Code
Model
-
Absorbed Max.
Current (A)
Motor
power W
Motor
polarity
Air flow
m3/h
Sound
dB (A)
Insulation
class
Protection
index
Weight
Kg
2 x 2,8
2 x 4,7
2 x 0,86
2 x 1,55
2 x 2,8
2 x 4,7
2 x 0,86
2 x 1,55
2 x 2,8
2 x 4,7
2 x 0,86
2 x 1,55
2 x 2,8
2 x 4,7
2 x 0,86
2 x 1,55
2 x 2,8
2 x 4,7
2 x 0,86
2 x 1,55
2 x 2,8
2 x 4,7
2 x 0,86
2 x 1,55
2 x 2,8
2 x 4,7
2 x 375
2 x 550
2 x 195
2 x 355
2 x 375
2 x 550
2 x 195
2 x 355
2 x 375
2 x 550
2 x 195
2 x 355
2 x 375
2 x 550
2 x 195
2 x 355
2 x 375
2 x 550
2 x 195
2 x 355
2 x 375
2 x 550
2 x 195
2 x 355
2 x 375
2 x 550
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
1890
2800
590
890
1890
2800
590
890
1890
2800
590
890
1890
2800
590
890
1890
2800
590
890
1890
2800
590
890
1890
2800
53
56
50
52
53
56
50
52
53
56
50
52
53
56
50
52
53
56
50
52
53
56
50
52
53
56
B
F
F
F
B
F
F
F
B
F
F
F
B
F
F
F
B
F
F
F
B
F
F
F
B
F
44
44
20
20
44
44
20
20
44
44
20
20
44
44
20
20
44
44
20
20
44
44
20
20
44
44
130
150
34
70
130
150
34
70
130
150
34
70
130
150
34
70
130
150
34
70
130
150
34
70
130
150
Motor
polarity
Air flow
m3/h
Sound
dB (A)
Insulation
class
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
4 Poles
3700
5100
3700
5100
3700
5100
3700
5100
3700
5100
3700
5100
3700
5100
3700
5100
3700
5100
3700
5100
3700
5100
3700
5100
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
RCIB EC H 1900
RCIB EC H 2800
RCIB WC H 600 BP
RCIB WC H 900 BP
RCIB WC H 1900 BP
RCIB WC H 2800 BP
RCIB EC H 600 BP
RCIB EC H 900 BP
RCIB EC H 1900 BP
RCIB EC H 2800 BP
RCIB WC V 600
RCIB WC V 900
RCIB WC V 1900
RCIB WC V 2800
RCIB EC V 600
RCIB EC V 900
RCIB EC V 1900
RCIB EC V 2800
RCIB WC V 600 BP
RCIB WC V 900 BP
RCIB WC V 1900 BP
RCIB WC V 2800 BP
RCIB EC V 600 BP
RCIB EC V 900 BP
RCIB EC V 1900 BP
RCIB EC V 2800 BP
R.R.P.
€
4.109,30
5.570,70
3.536,90
3.783,60
4.812,10
6.231,50
3.076,20
3.411,30
4.388,60
5.877,80
3.471,80
3.727,70
4.798,10
6.292,00
2.983,10
3.336,80
4.356,00
5.919,70
3.765,00
4.025,60
5.114,60
6.631,70
3.267,00
3.625,30
4.663,20
6.250,10
THREE PHASE RANGE
Code
Model
300728200
300728300
-
RCIB H 3700
RCIB H 5100
RCIB V 3700
RCIB V 5100
RCIB H 3700 BP
RCIB H 5100 BP
RCIB V 3700 BP
RCIB V 5100 BP
RCIB WC H 3700
RCIB WC H 5100
RCIB EC H 3700
RCIB EC H 5100
RCIB WC H 3700 BP
RCIB WC H 5100 BP
RCIB EC H 3700 BP
RCIB EC H 5100 BP
RCIB WC V 3700
RCIB WC V 5100
RCIB EC V 3700
RCIB EC V 5100
RCIB WC V 3700 BP
RCIB WC V 5100 BP
RCIB EC V 3700 BP
RCIB EC V 5100 BP
H
BP
V
EC
WC
Absorbed Max. Motor power
Current (A)
W
2 x 3,2
2 x 5,4
2 x 3,2
2 x 5,4
2 x 3,2
2 x 5,4
2 x 3,2
2 x 5,4
2 x 3,2
2 x 5,4
2 x 3,2
2 x 5,4
2 x 3,2
2 x 5,4
2 x 3,2
2 x 5,4
2 x 3,2
2 x 5,4
2 x 3,2
2 x 5,4
2 x 3,2
2 x 5,4
2 x 3,2
2 x 5,4
2 x 750
2 x 1500
2 x 750
2 x 1500
2 x 750
2 x 1500
2 x 750
2 x 1500
2 x 750
2 x 1500
2 x 750
2 x 1500
2 x 750
2 x 1500
2 x 750
2 x 1500
2 x 750
2 x 1500
2 x 750
2 x 1500
2 x 750
2 x 1500
2 x 750
2 x 1500
Protection Weight
index
Kg
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
R.R.P.
€
6.403,70
6.836,50
6.790,00
7.255,30
6.724,80
7.162,30
7.134,30
7.609,00
7.329,80
7.758,00
6.957,50
7.502,00
7.664,90
8.107,00
7.287,90
7.846,40
7.785,90
8.251,30
7.385,70
7.972,00
8.148,90
8.623,60
7.744,00
8.344,30
HORIZONTAL
BYPASS
VERTICAL
ELECTRICAL COIL
WATER COIL
37
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
HBF-HBFX
Axial fan 400ºC/2h
MANUFACTURING FEATURES
• Axial fan with circular reinforced frame.
• Modular motor-impeller assembly.
• Cast aluminium impeller with variable pitch angle. Epoxy powder finishing coat.
• Standard asynchronous squirrel cage motor with
IP-55 protection and Class H insulation certified
400ºC/2h. Standard voltages 230/400V 50Hz
in three phase, motors up to 4kW and 400/690V
50Hz for higher powers.
UNDER REQUEST
• B Form impeller (air flow from impeller to motor),
100% reversible impeller (5% additional cost).
• 300ºC/2h motor.
• ATEX models (HBFX). 10% additional cost.
HBF
APPLICATIONS
Designed for wall or duct installation, they are suitable for:
• Smoke emergency exhaust with motor inside the
hazardous area.
• Maximum working temperature: 60ºC.
INSIDE
HBFX
ACCESSORIES
38
RFS
INT
PE
MC HB
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
THREE PHASE RANGE
Model
HBF / HBFX
R.P.M.
max.
HBF 40 T4 0,55kW
HBF 40 T4 0,75kW
HBF 45 T4 0,55kW
HBF 45 T4 0,75kW
HBF 45 T6 0,55kW
HBF 50 T4 0,55kW
HBF 50 T4 0,75kW
HBF 50 T6 0,55kW
HBF 56 T4 0,75kW
HBF 56 T4 1,1kW
HBF 56 T4 1,5kW
HBF 56 T6 0,55kW
HBF 63 T4 0,75kW
HBF 63 T4 1,1kW
HBF 63 T4 1,5kW
HBF 63 T4 2,2kW
HBF 63 T4 3kW
HBF 63 T6 0,55kW
HBF 63 T6 0,75kW
HBF 71 T4 1,1kW
HBF 71 T4 1,5kW
HBF 71 T4 2,2kW
HBF 71 T4 3kW
HBF 71 T6 0,55kW
HBF 71 T6 0,75kW
HBF 71 T6 1,1kW
HBF 80 T4 2,2kW
HBF 80 T4 3kW
HBF 80 T4 4kW
HBF 80 T6 0,75kW
HBF 80 T6 1,1kW
HBF 80 T6 1,5kW
HBF 80 T6 2,2kW
HBF 90 T4 3kW
HBF 90 T4 4kW
HBF 90 T4 5,5kW
HBF 90 T4 7,5kW
HBF 90 T6 1,5kW
HBF 90 T6 2,2kW
HBF 90 T6 3kW
HBF 100 T4 5,5kW
HBF 100 T4 7,5kW
HBF 100 T4 11kW
HBF 100 T4 15kW
HBF 100 T6 2,2kW
HBF 100 T6 3kW
HBF 100 T6 4kW
HBF 125 T4 11kW
HBF 125 T4 15kW
HBF 125 T4 18,5kW
HBF 125 T4 22kW
HBF 125 T6 3kW
HBF 125 T6 4kW
HBF 125 T6 7,5kW
HBF 125 T6 11kW
1400
1415
1400
1415
920
1400
1415
920
1415
1430
1435
920
1415
1430
1435
1455
1455
920
920
1430
1435
1455
1455
920
920
920
1455
1455
1455
920
920
960
960
1455
1455
1455
1455
960
960
945
1455
1455
1455
1455
960
945
945
1455
1455
1465
1465
945
945
968
966
Max. Curr. (A)
230 400 690
2,69
3,46
2,69
3,46
2,6
2,69
3,46
2,6
3,46
4,33
5,89
2,6
3,46
4,33
5,89
7,97
10,74
2,6
3,46
4,33
5,89
7,97
10,74
2,6
3,46
5,11
7,97
10,74
3,46
5,11
6,41
9,01
10,74
6,41
9,01
12,12
9,01
12,12
12,12
-
1,56
2
1,56
2
1,5
1,56
2
1,5
2
2,5
3,4
1,5
2
2,5
3,4
4,6
6,2
1,5
2
2,5
3,4
4,6
6,2
1,5
2
2,95
4,6
6,2
8,2
2
2,95
3,7
5,2
6,2
8,2
10,8
14,5
3,7
5,2
7
10,8
14,5
20,9
27,9
5,2
7
9,3
20,9
27,9
35
40,8
7
9,3
16
23
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg HBF
0,55
0,75
0,55
0,75
0,55
0,55
0,75
0,55
0,75
1,1
1,5
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
2,2
3
4
0,75
1,1
1,5
2,2
3
4
5,5
7,5
1,5
2,2
3
5,5
7,5
11
15
2,2
3
4
11
15
18,5
22
3
4
7,5
11
4500
4700
7300
7500
5200
9200
10065
6000
12650
13970
15600
10170
14080
16500
18620
21010
23430
12430
13860
20570
22000
23870
27060
15400
17480
19640
29700
34980
38700
23100
25840
28600
30620
37540
44320
49370
55040
30580
35390
39910
53080
61590
66450
71510
37740
45690
51450
82600
89000
97300
103700
50000
55800
73600
88600
63
64
67
68
56
69
70
60
74
75
76
63
72
73
74
75
76
63
65
78
79
81
82
65
67
68
83
84
85
70
73
74
75
87
89
90
91
78
79
80
92
93
94
95
82
83
84
94
94
95
95
80
81
83
85
31
32
32
33
39
33
34
33
35
34
36
38
36
39
41
50
52
35
42
44
46
56
58
45
48
49
65
67
72
56
58
64
69
74
79
95
106
71
76
100
103
133
148
80
104
112
115
237
247
275
287
180
194
188
194
4,73
4,73
6,24
8,37
6,24
8,37
12,07
16,11
5,37
12,07
16,11
20,21
23,56
5,37
9,24
13,28
R.R.P. €
HBF 400ºC/2h
1.218,90
1.228,30
1.233,50
1.246,60
1.368,10
1.271,30
1.282,10
1.389,90
1.313,60
1.404,60
1.596,50
1.530,50
1.375,30
1.451,00
1.608,10
1.804,70
2.165,30
1.507,10
1.661,70
1.508,30
1.666,00
1.890,70
2.251,30
1.595,90
1.686,00
1.694,10
1.987,60
2.347,90
2.492,80
1.719,90
1.944,30
2.276,20
2.397,10
2.418,30
2.562,00
2.907,60
3.142,30
2.270,00
2.390,90
2.960,60
3.169,10
3.403,70
5.581,10
7.504,30
2.576,00
3.310,50
3.632,50
7.647,30
8.090,50
9.853,90
10.278,30
5.815,60
6.121,30
7.590,70
8.981,60
THREE PHASE RANGE 2 SPEEDS
Model
HBF / HBFX
HBF 40 T4/T8 0,75-0,15kW
HBF 45 T4/T8 0,75-0,15kW
HBF 50 T4/T8 0,75-0,15kW
HBF 56 T4/T8 0,75-0,15kW
HBF 56 T4/T8 1,1-0,18kW
HBF 56 T4/T8 1,5-0,25kW
HBF 63 T4/T8 0,75-0,15kW
HBF 63 T4/T8 1,1-0,18kW
HBF 63 T4/T8 1,5-0,25kW
HBF 63 T4/T8 2,2-0,37kW
HBF 63 T4/T8 3-0,55kW
HBF 71 T4/T8 1,1-0,18kW
HBF 71 T4/T8 1,5-0,25kW
HBF 71 T4/T8 2,2-0,37kW
HBF 71 T4/T8 3-0,55kW
HBF 80 T4/T8 2,2-0,37kW
HBF 80 T4/T8 3-0,55kW
HBF 80 T4/T8 4-0,75kW
R.P.M. max.
Max. Curr. (A)
400V
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
1420/710
1420/710
1420/710
1420/710
1430/715
1430/715
1420/710
1430/715
1430/715
1430/715
1445/725
1430/715
1430/715
1430/715
1445/725
1430/715
1445/725
1450/730
2,2/0,85
2,2/0,85
2,2/0,85
2,2/0,85
2,85/0,85
3,75/1,15
2,2/0,85
2,85/0,85
3,75/1,15
5,1/1,6
6,5/2,55
2,85/0,85
3,75/1,15
5,1/1,6
6,5/2,55
5,1/1,6
6,5/2,55
8,8/3,3
0,75/0,15
0,75/0,15
0,75/0,15
0,75/0,15
1,1/0,18
1,5/0,25
0,75/0,15
1,1/0,18
1,5/0,25
2,2/0,37
3/0,55
1,1/0,18
1,5/0,25
2,2/0,37
3/0,55
2,2/0,37
3/0,55
4/0,75
4700/2350
7500/3750
8500/4250
12650/6325
13970/6985
15600/7800
14080/7040
16500/8250
18620/9310
21010/10505
23430/11715
20570/10285
22000/11000
23870 / 11935
27060/13530
29700 / 14850
34980/17490
38700 / 19350
67/50
68/51
70/52
73/55
75/57
76/58
72/54
73/55
74/56
75/57
76/58
78/60
79/61
81/63
82/64
83/65
84/66
85/67
R.R.P. €
HBF 400ºC/2h
1.545,70
1.555,70
1.585,30
1.616,80
1.714,60
1.962,10
1.683,50
1.781,90
2.031,30
2.273,70
2.634,30
1.890,70
2.140,00
2.382,50
2.743,40
2.478,80
2.839,30
3.200,20
39
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
Model
HBF / HBFX
HBF 90 T4/T8 3-0,55kW
HBF 90 T4/T8 4-0,75kW
HBF 90 T4/T8 5,5-1,1kW
HBF 90 T4/T8 7,5-1,5kW
HBF 100 T4/T8 5,5-1,1kW
HBF 100 T4/T8 7,5-1,5kW
HBF 100 T4/T8 10-2kW
HBF 100 T4/T8 14-3kW
HBF 125 T4/T8 10-2kW
HBF 125 T4/T8 14-3kW
HBF 125 T4/T8 16,5-3,3kW
HBF 125 T4/T8 20-4kW
BOX HBF
BOX HBFX
R.P.M. max.
Max. Curr. (A)
400V
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
1445/725
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
6,5/2,55
8,8/3,3
11,1/3,5
16,5/5,2
11,1/3,5
15/4,7
16,5/5,2
29/7
16,5/5,2
29/7
35,4/7,9
42,3/8,2
3/0,55
4/0,75
5,5/1,1
10/2
5,5/1,1
7,5/1,5
10/2
14/3
10/2
14/3
16,5/3,3
20/4
37540/18770
44320 / 22160
49370/24685
55040 / 27520
53080/26540
61590/30795
66450/33225
71510/35755
82600/41300
89000/44500
97300/48650
103700/51850
87/69
89/71
90/72
94/76
92/74
93/75
94/76
95/77
95/77
96/78
96/78
97/79
R.R.P. €
HBF 400ºC/2h
2.907,60
3.266,00
3.689,50
4.289,40
3.980,90
4.555,50
7.288,60
8.562,60
9.263,60
10.400,90
10.966,70
17.643,30
Axial fan in soundproof cabinet 400ºC/2h
MANUFACTURING FEATURES
• BOX: Manufactured in galvanised steel sheet with
thermalproofing. Soundproof cabinets with Flexiroll
Pol Na 30 anthracite grey M1 fire resistance insulated panels. Removable panels for easy motor access and fan maintenance.
• Internal fan: HBF, axial fan with circular reinforced
frame. Modular motor-impeller assembly. Cast aluminium impeller with variable pitch angle. Epoxy
powder finishing coat.
BOX HBF
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class H insulation certified
400ºC/2H. Manufactured with standard voltages:
230/400V 50Hz in three phase motors up to 4kW,
and 400/690V 50Hz for higher powers.
APPLICATIONS
Designed for wall or duct installation, they are suitable for:
• Smoke emergency exhaust with motor inside the
hazardous area.
• Cabinet design simplifies installation in rectangular duct systems.
• Maximum working temperature: 60ºC.
UNDER REQUEST
• B form, 100% reversible impeller. 5% additional
cost.
• 300ºC/2h motor.
• ATEX models (BOX HBFX). 10% additional cost.
INSIDE
BOX HBFX
ACCESSORIES
RFS
INT
PE
THREE PHASE RANGE
Max. Curr. (A)
Model
BOX HBF / BOX HBFX
R.P.M.
max.
230
400
BOX HBF 40 T4 0,55kW
BOX HBF 40 T4 0,75kW
BOX HBF 45 T4 0,55kW
BOX HBF 45 T4 0,75kW
BOX HBF 45 T6 0,55kW
BOX HBF 50 T4 0,55kW
BOX HBF 50 T4 0,75kW
BOX HBF 50 T6 0,55kW
BOX HBF 56 T4 0,75kW
BOX HBF 56 T4 1,1kW
BOX HBF 56 T4 1,5kW
BOX HBF 56 T6 0,55kW
BOX HBF 63 T4 0,75kW
BOX HBF 63 T4 1,1kW
BOX HBF 63 T4 1,5kW
BOX HBF 63 T4 2,2kW
1400
1415
1400
1415
920
1400
1415
920
1415
1430
1435
920
1415
1430
1435
1455
2,69
3,46
2,69
3,46
2,6
2,69
3,46
2,6
3,46
4,33
5,89
2,6
3,46
4,33
5,89
7,97
1,56
2
1,56
2
1,5
1,56
2
1,5
2
2,5
3,4
1,5
2
2,5
3,4
4,6
40
690
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight Kg
BOX HBF
0,55
0,75
0,55
0,75
0,55
0,55
0,75
0,55
0,75
1,1
1,5
0,55
0,75
1,1
1,5
2,2
4500
4700
7300
7500
5200
9200
10065
11330
12650
13970
15600
10170
14080
16500
18620
21010
60
59
60
61
50
66
67
55
71
72
73
60
69
70
71
72
56
57
64
65
64
64
65
67
75
75
77
74
77
77
79
92
R.R.P. €
BOX HBF
400ºC/2h
1.770,30
1.790,20
1.798,10
1.811,00
1.938,80
1.801,30
1.818,40
1.941,00
1.925,90
2.053,70
2.256,90
2.186,90
2.010,00
2.090,00
2.256,50
2.463,90
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
Max. Curr. (A)
Model
BOX HBF / BOX HBFX
R.P.M.
max.
230
400
690
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight Kg
BOX HBF
BOX HBF 63 T4 3kW
BOX HBF 63 T6 0,55kW
BOX HBF 63 T6 0,75kW
BOX HBF 71 T4 1,1kW
BOX HBF 71 T4 1,5kW
BOX HBF 71 T4 2,2kW
BOX HBF 71 T4 3kW
BOX HBF 71 T6 0,55kW
BOX HBF 71 T6 0,75kW
BOX HBF 71 T6 1,1kW
BOX HBF 80 T4 2,2kW
BOX HBF 80 T4 3kW
BOX HBF 80 T4 4kW
BOX HBF 80 T6 0,75kW
BOX HBF 80 T6 1,1kW
BOX HBF 80 T6 1,5kW
BOX HBF 80 T6 2,2kW
BOX HBF 90 T4 3kW
BOX HBF 90 T4 4kW
BOX HBF 90 T4 5,5kW
BOX HBF 90 T4 7,5kW
BOX HBF 90 T6 1,5kW
BOX HBF 90 T6 2,2kW
BOX HBF 90 T6 3kW
BOX HBF 100 T4 5,5kW
BOX HBF 100 T4 7,5kW
BOX HBF 100 T4 11kW
BOX HBF 100 T4 15kW
BOX HBF 100 T6 2,2kW
BOX HBF 100 T6 3kW
BOX HBF 100 T6 4kW
BOX HBF 125 T4 11kW
BOX HBF 125 T4 15kW
BOX HBF 125 T4 18,5kW
BOX HBF 125 T4 22kW
BOX HBF 125 T6 3kW
BOX HBF 125 T6 4kW
BOX HBF 125 T6 7,5kW
BOX HBF 125 T6 11kW
1455
920
920
1430
1435
1455
1455
920
920
920
1455
1455
1455
920
920
960
960
1455
1455
1455
1455
960
960
945
1455
1455
1455
1455
960
945
945
1455
1455
1465
1465
945
945
968
966
10,74
2,6
3,46
4,33
5,89
7,97
10,74
2,6
3,46
5,11
7,97
10,74
3,46
5,11
6,41
9,01
10,74
6,41
9,01
12,12
9,01
12,12
12,12
-
6,2
1,5
2
2,5
3,4
4,6
6,2
1,5
2
2,95
4,6
6,2
8,2
2
2,95
3,7
5,2
6,2
8,2
10,8
14,5
3,7
5,2
7
10,8
14,5
20,9
27,9
5,2
7
9,3
20,9
27,9
35
40,8
7
9,3
16
23
4,73
4,73
6,24
8,37
6,24
8,37
12,07
16,11
5,37
12,07
16,11
20,21
23,56
5,37
9,24
13,28
3
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
2,2
3
4
0,75
1,1
1,5
2,2
3
4
5,5
7,5
1,5
2,2
3
5,5
7,5
11
15
2,2
3
4
11
15
18,5
22
3
4
7,5
11
23430
12430
13860
20570
22000
23870
27060
15400
17480
19640
29700
34980
38700
23100
25840
28600
30620
37540
44320
49370
55040
30580
35390
39910
53080
61590
66450
71510
37740
45690
51450
82600
89000
97300
103700
50000
55800
64800
73600
73
61
62
75
76
77
78
63
64
65
80
81
82
67
70
71
72
84
85
87
88
75
76
77
89
89
90
91
79
80
81
91
91
92
92
77
78
80
82
103
80
80
98
100
113
125
98
98
105
119
130
130
112
115
117
129
160
160
191
195
147
159
188
197
201
254
264
165
194
211
302
312
340
352
245
259
263
259
R.R.P. €
BOX HBF
400ºC/2h
2.912,00
2.150,00
2.313,70
2.278,70
2.445,00
2.682,80
3.064,10
2.285,40
2.466,50
2.519,10
2.711,70
3.092,40
3.244,90
2.495,00
2.503,70
2.853,60
3.021,10
3.465,40
3.617,50
3.995,00
4.241,50
3.212,80
3.447,40
4.049,90
4.107,00
4.355,50
6.851,50
7.808,70
3.565,50
4.168,30
4.508,90
8.820,10
9.263,30
11.026,80
11.451,10
6.988,50
7.294,20
8.763,50
10.154,50
THREE PHASE RANGE 2 SPEEDS
Model
BOX HBF / BOX HBFX
BOX HBF 40 T4/T8 0,75-0,15kW
BOX HBF 45 T4/T8 0,75-0,15kW
BOX HBF 50 T4/T8 0,75-0,15kW
BOX HBF 56 T4/T8 0,75-0,15kW
BOX HBF 56 T4/T8 1,1-0,18kW
BOX HBF 56 T4/T8 1,5-0,25kW
BOX HBF 63 T4/T8 0,75-0,15kW
BOX HBF 63 T4/T8 1,1-0,18kW
BOX HBF 63 T4/T8 1,5-0,25kW
BOX HBF 63 T4/T8 2,2-0,37kW
BOX HBF 63 T4/T8 3-0,55kW
BOX HBF 71 T4/T8 1,1-0,18kW
BOX HBF 71 T4/T8 1,5-0,25kW
BOX HBF 71 T4/T8 2,2-0,37kW
BOX HBF 71 T4/T8 3-0,55kW
BOX HBF 80 T4/T8 2,2-0,37kW
BOX HBF 80 T4/T8 3-0,55kW
BOX HBF 80 T4/T8 4-0,75kW
BOX HBF 90 T4/T8 3-0,55kW
BOX HBF 90 T4/T8 4-0,75kW
BOX HBF 90 T4/T8 5,5-1,1kW
BOX HBF 90 T4/T8 7,5-1,5kW
BOX HBF 100 T4/T8 5,5-1,1kW
BOX HBF 100 T4/T8 7,5-1,5kW
BOX HBF 100 T4/T8 10-2kW
BOX HBF 100 T4/T8 14-3kW
BOX HBF 125 T4/T8 10-2kW
BOX HBF 125 T4/T8 14-3kW
BOX HBF 125 T4/T8 16,5-3,3kW
BOX HBF 125 T4/T8 20-4kW
R.P.M. max.
Max. Curr. (A)
400V
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
1420/710
1420/710
1420/710
1420/710
1430/715
1430/715
1420/710
1430/715
1430/715
1430/715
1445/725
1430/715
1430/715
1430/715
1445/725
1430/715
1445/725
1450/730
1445/725
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
2,2/0,85
2,2/0,85
2,2/0,85
2,2/0,85
2,85/0,85
3,75/1,15
2,2/0,85
2,85/0,85
3,75/1,15
5,1/1,6
6,5/2,55
2,85/0,85
3,75/1,15
5,1/1,6
6,5/2,55
5,1/1,6
6,5/2,55
8,8/3,3
6,5/2,55
8,8/3,3
11,1/3,5
15/4,7
11,1/3,5
15/4,7
16,5/5,2
29/7
16,5/5,2
29/7
35,4/7,9
42,3/8,2
0,75/0,15
0,75/0,15
0,75/0,15
0,75/0,15
1,1/0,18
1,5/0,25
0,75/0,15
1,1/0,18
1,5/0,25
2,2/0,37
3/0,55
1,1/0,18
1,5/0,25
2,2/0,37
3/0,55
2,2/0,37
3/0,55
4/0,75
3/0,55
4/0,75
5,5/1,1
7,5/1,5
5,5/1,1
7,5/1,5
10/2
14/3
10/2
14/3
16,5/3,3
20/4
4700/2350
7500/3750
8500/4250
12650/6325
13970/6985
15600/7800
14080/7040
16500/8250
18620/9310
21010/10505
23430/11715
20570/10285
22000/11000
23870/11935
27060/13530
29700/14850
34980/17490
38700/19350
37540/18770
44320/22160
49370/24685
55040 / 27520
53080/26540
61590/30795
66450/33225
71510/35755
75000/37500
89000/44500
97200/48600
103700/51850
67/50
65/48
67/49
70/52
72/53
73/58
69/51
70/52
71/53
72/54
73/55
75/57
76/58
78/60
79/61
80/62
81/63
82/64
84/66
86/68
87/69
91/73
89/71
90/72
91/73
92/74
92/74
93/75
93/75
94/76
R.R.P. €
BOX HBF
400ºC/2h
2.070,90
2.150,60
2.148,00
2.360,90
2.464,90
2.728,40
2.336,10
2.464,50
2.728,40
2.983,30
3.431,00
2.653,60
2.946,30
3.203,10
3.584,10
3.230,70
3.612,40
3.994,40
4.078,50
4.459,80
4.758,60
5.366,30
4.877,10
5.484,70
8.375,20
9.722,10
10.436,50
11.573,70
12.139,50
18.816,10
41
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
HMF-HMFX
Long cased axial fan 400ºC/2h
MANUFACTURING FEATURES
• Long cased axial fan with reinforced body.
• Modular motor-impeller assembly. Cast aluminium impeller with variable pitch angle. Epoxy
powder finishing coat.
• Housing with motor access door.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class H insulation certified
400ºC/2h. Manufactured with standard voltages:
230/400V 50Hz in three phase motors up to 4kW,
and 400/690V 50Hz for higher powers.
HMF
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Smoke emergency exhaust with motor inside the
hazardous area.
• Maximum working temperature: 60ºC.
UNDER REQUEST
• B form, 100% reversible impeller. 5% additional
cost.
• 300ºC/2h motor.
• ATEX models (HMFX). 10% additional cost.
INSIDE
HMFX
ACCESSORIES
RFS
INT
PE
RP
AC
BA-400
SIL-C
PO
THREE PHASE RANGE
Model
HMF / HMFX
HMF 40 T4 0,55kW
HMF 40 T4 0,75kW
HMF 45 T4 0,55kW
HMF 45 T4 0,75kW
HMF 45 T6 0,55kW
HMF 50 T4 0,55kW
HMF 50 T4 0,75kW
HMF 50 T6 0,55kW
HMF 56 T4 0,75kW
HMF 56 T4 1,1kW
HMF 56 T4 1,5kW
HMF 56 T6 0,55kW
HMF 63 T4 0,75kW
HMF 63 T4 1,1kW
HMF 63 T4 1,5kW
HMF 63 T4 2,2kW
HMF 63 T4 3kW
HMF 63 T6 0,55kW
HMF 63 T6 0,75kW
HMF 71 T4 1,1kW
HMF 71 T4 1,5kW
HMF 71 T4 2,2kW
HMF 71 T4 3kW
HMF 71 T6 0,55kW
HMF 71 T6 0,75kW
HMF 71 T6 1,1kW
HMF 80 T4 2,2kW
HMF 80 T4 3kW
HMF 80 T4 4kW
HMF 80 T6 0,75kW
HMF 80 T6 1,1kW
HMF 80 T6 1,5kW
HMF 80 T6 2,2kW
HMF 90 T4 3kW
HMF 90 T4 4kW
HMF 90 T4 5,5kW
HMF 90 T4 7,5kW
42
Max. Curr. (A)
R.P.M.
max.
230
400
690
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg HMF
1400
1415
1400
1415
920
1400
1415
920
1415
1430
1435
920
1415
1430
1435
1455
1455
920
920
1430
1435
1455
1455
920
920
920
1455
1455
1455
920
920
960
960
1455
1455
1455
1455
2,69
3,46
2,69
3,46
2,6
2,69
3,46
2,6
3,46
4,33
5,89
2,6
3,46
4,33
5,89
7,97
10,74
2,6
3,46
4,33
5,89
7,97
10,74
2,6
3,46
5,11
7,97
10,74
3,46
5,11
6,41
9,01
10,74
-
1,56
2
1,56
2
1,5
1,56
2
1,5
2
2,5
3,4
1,5
2
2,5
3,4
4,6
6,2
1,5
2
2,5
3,4
4,6
6,2
1,5
2
2,95
4,6
6,2
8,2
2
2,95
3,7
5,2
6,2
8,2
10,8
14,5
4,73
4,73
6,24
8,37
0,55
0,75
0,55
0,75
0,55
0,55
0,75
0,55
0,75
1,1
1,5
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
2,2
3
4
0,75
1,1
1,5
2,2
3
4
5,5
7,5
4500
4700
7300
7500
5200
9200
10065
6000
12650
13970
15600
10170
14080
16500
18620
21010
23430
12430
13860
20570
22000
23870
27060
15400
17480
19640
29700
34980
38700
23100
25840
28600
30620
37540
44320
49370
55040
63
64
67
68
56
69
70
60
74
75
76
63
72
73
74
75
76
64
65
78
79
80
81
66
67
68
83
84
85
70
73
74
75
87
88
90
94
68
69
70
71
70
72
73
72
75
78
79
74
76
77
78
80
84
80
84
87
100
103
106
98
102
105
112
130
135
139
115
120
124
138
160
180
186
R.R.P. €
HMF 400ºC/2h
1.496,30
1.512,50
1.514,10
1.527,90
1.688,40
1.530,10
1.544,00
1.704,40
1.559,40
1.635,10
1.817,10
1.718,20
1.576,70
1.798,20
2.017,40
2.253,30
2.686,30
2.153,10
2.355,10
1.906,00
2.092,80
2.331,00
2.747,00
1.970,50
2.014,50
2.114,00
2.544,80
2.862,60
3.029,20
2.210,00
2.344,00
2.693,40
2.775,30
3.074,10
3.101,40
3.503,90
3.775,80
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
Max. Curr. (A)
Model
HMF / HMFX
R.P.M.
max.
230
400
690
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg HMF
HMF 90 T6 1,5kW
HMF 100 T6 2,2kW
HMF 100 T6 3kW
HMF 100 T6 4kW
HMF 125 T4 11kW
HMF 125 T4 15kW
HMF 125 T4 18,5kW
HMF 125 T4 22kW
HMF 125 T6 3kW
HMF 125 T6 4kW
HMF 125 T6 7,5kW
HMF 125 T6 11kW
HMF 125 T4 18,5kW
HMF 125 T4 22kW
HMF 125 T6 3kW
HMF 125 T6 4kW
HMF 125 T6 7,5kW
960
960
945
945
1455
1455
1465
1465
945
945
968
966
1465
1465
945
945
968
6,41
9,01
12,12
12,12
12,12
-
3,7
5,2
7
9,3
20,9
27,9
35
40,8
7
9,3
16
23
35
40,8
7
9,3
16
5,37
12,07
16,11
20,21
23,56
5,37
9,24
13,28
20,21
23,56
5,37
9,24
1,5
2,2
3
4
11
15
18,5
22
3
4
7,5
11
18,5
22
3
4
7,5
30580
37740
45690
51450
82600
89000
97300
103700
50000
55800
64800
73600
97300
103700
50000
55800
64800
78
82
83
84
91
91
92
92
77
78
80
82
92
92
77
78
80
191
158
162
167
433
445
480
495
361
379
384
379
480
495
361
379
384
R.R.P. €
HMF 400ºC/2h
3.083,40
3.656,40
3.299,60
3.871,30
8.038,20
8.481,40
10.244,90
10.669,20
6.206,60
6.512,30
7.981,60
9.372,60
10.244,90
10.669,20
6.206,60
6.512,30
7.981,60
THREE PHASE RANGE 2 SPEEDS
Model
HMF / HMFX
HMF 40 T4/T8 0,75-0,15kW
HMF 45 T4/T8 0,75-0,15kW
HMF 50 T4/T8 0,75-0,15kW
HMF 56 T4/T8 0,75-0,15kW
HMF 56 T4/T8 1,1-0,18kW
HMF 56 T4/T8 1,5-0,25kW
HMF 63 T4/T8 0,75-0,15kW
HMF 63 T4/T8 1,1-0,18kW
HMF 63 T4/T8 1,5-0,25kW
HMF 63 T4/T8 2,2-0,37kW
HMF 63 T4/T8 3-0,55kW
HMF 71 T4/T8 1,1-0,18kW
HMF 71 T4/T8 1,5-0,25kW
HMF 71 T4/T8 2,2-0,37kW
HMF 71 T4/T8 3-0,55kW
HMF 80 T4/T8 2,2-0,37kW
HMF 80 T4/T8 3-0,55kW
HMF 80 T4/T8 4-0,75kW
HMF 90 T4/T8 3-0,55kW
HMF 90 T4/T8 4-0,75kW
HMF 90 T4/T8 5,5-1,1kW
HMF 90 T4/T8 7,5-1,5kW
HMF 100 T4/T8 5,5-1,1kW
HMF 100 T4/T8 7,5-1,5kW
HMF 100 T4/T8 10-2kW
HMF 125 T4/T8 10-2kW
HMF 125 T4/T8 14-3kW
HMF 125 T4/T8 16,5-3,3kW
HMF 125 T4/T8 20-4kW
R.P.M. max.
Max. Curr. (A)
400V
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg HMF
1420/710
1420/710
1420/710
1420/710
1430/715
1430/715
1420/710
1430/715
1430/715
1430/715
1445/725
1430/715
1430/715
1430/715
1445/725
1430/715
1445/725
1450/730
1445/725
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
1450/730
2,2/0,85
2,2/0,85
2,2/0,85
2,2/0,85
2,85/0,85
3,75/1,15
2,2/0,85
2,85/0,85
3,75/1,15
5,1/1,6
6,5/2,55
2,85/0,85
3,75/1,15
5,1/1,6
6,5/2,55
5,1/1,6
6,5/2,55
8,8/3,3
6,5/2,55
8,8/3,3
11,1/3,5
15/4,7
11,1/3,5
15/4,7
16,5/5,2
16,5/5,2
29/7
35,4/7,9
42,3/8,2
0,75/0,15
0,75/0,15
0,75/0,15
0,75/0,15
1,1/0,18
1,5/0,25
0,75/0,15
1,1/0,18
1,5/0,25
2,2/0,37
3/0,55
1,1/0,18
1,5/0,25
2,2/0,37
3/0,55
2,2/0,37
3/0,55
4/0,75
3/0,55
4/0,75
5,5/1,1
7,5/1,5
5,5/1,1
7,5/1,5
10/2
10/2
14/3
16,5/3,3
20/4
4700/2350
7500/3750
8500/4250
12650/6325
13970/6985
15600/7800
14080/7040
16500/8250
18620/9310
21010/10505
23430/11715
20570/10285
22000/11000
23870/11935
27060/13530
29700/14850
34980/17490
38700/19350
37540/18770
44320/22160
49370/24685
55040 / 27520
53080/26540
61590/30795
66450/33225
82600/41300
89000/44500
97300/48650
103700/51850
67/50
68/51
70/52
73/55
75/57
76/58
72/54
73/55
74/56
75/57
76/58
78/60
79/61
81/63
82/64
83/65
84/66
85/67
87/69
89/71
90/72
94/76
92/74
93/75
94/76
92/74
93/75
93/75
94/76
69
71
73
75
78
79
76
77
78
80
84
87
100
103
106
112
130
135
138
160
180
186
163
169
172
433
445
480
495
R.R.P. €
HMF
400ºC/2h
1.828,90
1.851,00
1.900,60
1.968,60
2.290,20
2.398,50
2.220,30
2.381,10
2.651,00
2.791,80
2.968,70
2.509,20
2.707,20
3.109,10
2.905,30
3.002,40
3.404,50
3.473,70
3.779,30
4.355,20
4.551,70
4.886,10
4.547,60
5.166,60
7.993,10
9.488,60
10.791,80
11.357,60
18.034,20
43
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
JF
Jet fan 400ºC/2h - 300ºC/2h
MANUFACTURING FEATURES
Jet fan models are composed of an axial fan and
two silencers.
FAN:
• Axial fan with galvanised steel casing. Connection
box accessible from the side by a removable door.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class H insulation, CERTIFIED 400ºc/2h or 300ºc/2h. Standard voltages
230/400V 50Hz for 1 speed motors and 400V
50Hz for 2 speed motors.
SILENCERS:
• Casing made of galvanised steel. Inner duct
made of perforated galvanised steel sheet. Silencers
filled with mineral wool of high acoustic absorption
properties, preventing most of the fan noise to be
propagated.
• Unidirectional JF UN is equipped with a protection guard at the inlet side and a deflector at the
outlet.
• Reversible JF RE is equipped with deflectors on
both sides. The deflector directs the air away from
the ceiling and obstacles such as beams or ducting, sweeping the whole volume of air to the closest
extraction point.
APPLICATIONS
• Conceived for car parkings and large spaces
where polluted air or smoke from an accidental fire
needs to be removed effectively. An optimized design minimizes the height needed for their installation and assures a silent operation.
• Maximum working temperature: 60ºC.
UNDER REQUEST
• Epoxy painted casing in blue or grey.
INSIDE
ACCESSORIES
RFS
INT
PE
THREE PHASE RANGE
Model
Thrust
(N)
Discharge
speed (m/s)
JF 300 T2 UN
JF 300 T2 RE
JF 400 T2 UN
JF 400 T2 RE
30,7
20,1
53,6
47,9
22
18
20
19
R.P.M.
max.
2875
2875
2875
2875
Max. Curr. (A) Rated Power
kW
230
400
2,86
2,86
3,98
3,98
1,65
1,65
2,3
2,3
0,75
0,75
1,1
1,1
Air flow
m3/h
Sound
dB (A)
Weight
Kg
5750
4600
9600
8900
47
46
53
51
60
60
70
70
R.R.P. €
400ºC/2h
2.340,00
2.457,00
3.016,00
3.166,80
R.R.P. €
300ºC/2h
2.106,00
2.211,30
2.714,40
2.850,10
THREE PHASE RANGE 2 SPEEDS
Model
Thrust
(N)
JF 300 T2/T4 UN
JF 300 T2/T4 RE
JF 400 T2/T4 UN
JF 400 T2/T4 RE
30,7/7,7
20,1/5
53,6/13,4
47,9/12
44
Discharge
speed (m/s)
22/11
18/9
20/10
19/9,5
R.P.M.
máx.
2860/1460
2850/1460
2860/1460
2850/1460
Max. C. (A) Rated Power
kW
230
1,7/0,4
1,7/0,4
2,4/0,5
2,4/0,5
0,75/0,12
0,75/0,12
1,1/0,18
1,1/0,18
Air flow
m3/h
Sound
dB (A)
Weight
Kg
5750/2875
4600/2300
9600/4800
8900/4450
47/22
46/22
53/26
51/25
60
60
70
70
R.R.P. €
400ºC/2h
2.600,00
2.730,00
3.359,20
3.527,20
R.R.P. €
300ºC/2h
2.340,00
2.457,00
3.023,30
3.174,40
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
BOX RLF
BOX RLFX
Backward centrifugal impeller in soundproof cabinet 400ºC/2h
MANUFACTURING FEATURES
• Box manufactured in galvanised steel sheet.
• Circular inlet and outlet.
• Backward impeller, direct coupling motor.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class H insulation certified
400ºC/2h. Manufactured with standard voltages:
230/400V 50Hz in three phase motors up to 4kW,
and 400/690V 50Hz for higher powers.
• Interchangeable panels.
UNDER REQUEST
• Vertical discharge.
• 300ºC/2h motor.
• ATEX models (BOX RLFX).
BOX RLF
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Smoke emergency exhaust with motor inside the
hazardous area and high pressures needed.
• Maximum working temperature: 60ºC.
INSIDE
BOX RLFX
ACCESSORIES
RFS
INT
PE
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Max. Curr. (A)
Code
Model
BOX RLF / BOX RLFX
R.P.M.
max.
230
400
241410186
241430186
241450186
241500186
241510186
241560186
241580186
241570186
241590186
241630186
241640186
241710186
241740186
241720186
241750186
241800186
241810186
BOX RLF 400 T4/L 0,75kW
BOX RLF 400 T4/H 0,75kW
BOX RLF 450 T4 1,1kW
BOX RLF 500 T4 1,5kW
BOX RLF 500 T6 0,75kW
BOX RLF 560 T4/L 3kW
BOX RLF 560 T4/H 3kW
BOX RLF 560 T6/L 1,5kW
BOX RLF 560 T6/H 1,5kW
BOX RLF 630 T4 5,5kW
BOX RLF 630 T6 1,5kW
BOX RLF 710 T4/L 7,5kW
BOX RLF 710 T4/H 7,5kW
BOX RLF 710 T6/L 3kW
BOX RLF 710 T6/H 3kW
BOX RLF 800 T4 15kW
BOX RLF 800 T6 4kW
1400
1400
1400
1420
910
1410
1410
930
930
1450
930
1420
1420
955
955
1430
955
3,74
3,74
4,87
6,32
4,1
11,53
11,53
7,2
7,2
7,2
12,1
12,1
-
2,16
2,16
2,81
3,65
2,4
6,66
6,66
4,2
4,2
13,14
4,2
16,5
16,5
7
7
30,59
9,35
690
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
7,30
9,50
9,50
17,68
5,37
0,75
0,75
1,1
1,5
0,75
3
3
1,5
1,5
5,5
1,5
7,5
7,5
3
3
15
4
4500
4500
5971
9000
6180
11600
12378
7750
8250
17000
11673
21500
23000
15050
16500
27900
19500
52
61
62
64
54
66
68
56
57
69
59
71
72
63
65
75
66
90
95
120
135
135
185
190
175
180
210
200
225
230
215
220
280
270
R.R.P. €
BOX RLF
400º C/2h
2.225,90
2.431,30
2.523,70
2.487,40
2.650,10
2.719,40
2.799,80
2.656,30
2.754,30
4.332,80
3.053,00
4.681,30
4.800,90
3.743,00
3.856,00
6.772,80
4.727,80
THREE PHASE RANGE 2 SPEEDS
Model
BOX RLF / BOX RLFX
R.P.M.
max.
BOX RLF 400/H T4/T8 0,75-0,15kW
BOX RLF 450 T4/T8 1,1-0,18kW
BOX RLF 500 T4/T8 1,5-0,25kW
BOX RLF 560/H T4/T8 3-0,55kW
BOX RLF 630 T4/T8 5,5-1,1kW
BOX RLF 710/H T4/T8 7,5-1,5kW
BOX RLF 800 T4/T8 14-3kW
1380/685
1370/695
1375/700
1400/700
1455/720
1455/720
1470/730
Max. Curr. (A) 400V
3000 1500
-
1,76
2,4
3,3
5,3
10,3
13,3
28,6
750
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
0,77
1,25
1,80
2,80
3,30
4,40
9,3
0,75/0,15
1,1/0,18
1,5/0,25
3/0,55
5,5/1,1
7,5/1,5
14/3
3950/2000
5971/2980
8250/4125
12275/6150
16300/8150
23623/11810
27900/13950
61/49
64/51
66/53
68/54
71/57
73/59
77/62
R.R.P. €
BOX RLF
400º C/2h
2.796,00
2.902,30
2.860,50
3.219,70
4.982,70
5.521,10
7.788,80
45
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
MBRF
Backward centrifugal 400ºC/2h
MANUFACTURING FEATURES
• Reinforced rolling steel sheet housings completely
welded (internally and externally). Epoxy powder
finishing coat.
• Reinforced high efficiency backward curved impeller.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class H insulation certified
400ºC/2h. Manufactured with standard voltages:
230/400V 50Hz in three phase motors up to 4kW,
and 400/690V 50Hz for higher powers.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Smoke emergency exhaust with motor inside the
hazardous area and high pressures needed.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
UNDER REQUEST
• Drain plug and inspection door.
• 300ºC/2h motor.
• 2 speed motors.
INSIDE
ACCESSORIES
RFS
INT
PE
AC
EI
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Code
243400108
243450108
243510108
243500108
243570108
243560108
243650108
243640108
243730108
243720108
46
Model
MBRF 40/12 T4 0,75kW
MBRF 45/14 T4 1,1kW
MBRF 50/16 T4 1,5kW
MBRF 50/16 T6 0,75kW
MBRF 56/18 T4 3kW
MBRF 56/18 T6 1,5kW
MBRF 63/20 T4 5,5kW
MBRF 63/20 T6 1,5kW
MBRF 71/22 T4 7,5kW
MBRF 71/22 T6 3kW
R.P.M. max.
1415
1430
1435
920
1455
960
1455
960
1455
945
Max. Curr. (A)
230 400 690
3,46
4,33
5,89
3,46
10,74
6,41
6,41
12,12
2
2,5
3,4
2
6,2
3,7
10,8
3,7
14,5
7
6,24
8,37
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,75
1,1
1,5
0,75
3
1,5
5,5
1,5
7,5
3
5640
7200
9500
7100
13500
9500
19000
12000
25500
17000
73
76
81
71
83
73
84
76
87
77
98
109
125
122
145
135
258
220
345
335
R.R.P.
€
2.189,20
2.612,70
3.358,50
3.252,80
4.303,50
4.087,50
5.095,30
4.507,60
5.416,50
6.307,50
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
SF
Axial roof fan with adjustable inclination base 400ºC/2h - 300ºC/2h
MANUFACTURING FEATURES
• Fully manufactured in galvanised steel sheet.
• Variable pitch angle aluminium impeller.
• Bird protection guard included.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class H insulation certified
400ºC/2h.
• Manufactured with standard voltages: 230/400V
50Hz in three phase motors.
APPLICATIONS
Specially designed for roof installation, they are
suitable for:
• Smoke emergency exhaust.
• Air renewal in buildings and industries.
• Maximum working temperature: 60ºC.
UNDER REQUEST
• B form impeller (air flow from impeller to motor),
100% reversible impeller.
• Aluminium impeller.
• 60Hz fans and special voltages.
• Flameproof and explosion-proof fans with ATEX
certified motors and 3 meter RVFV 4x2,5mm core
cable.
• Custom pitch according to roof slope:
Type A: from 0% to 16%
Type B: from 16% to 38%
• Motorised damper with registered motor in IP-65
box to avoid heat loss in winter.
• ‘Double channel’ function to exhaust air in
dropped ceilings or closed environments and save
energy.
• Lacquered or stainless steel finishing coats.
• 300ºC/2h motor.
INSIDE
ACCESSORIES
RFS
INT
PE
THREE PHASE RANGE
Model
R.P.M. max.
SF 450 T6 0,55kW
SF 560 T4 0,75kW
SF 560 T4 1,1kW
SF 560 T4 1,5kW
SF 560 T6 0,55kW
SF 630 T4 0,75kW
SF 630 T4 1,1kW
SF 630 T4 1,5kW
SF 630 T4 2,2kW
SF 630 T4 3kW
SF 630 T6 0,55kW
SF 630 T6 0,75kW
SF 710 T4 1,1kW
SF 710 T4 1,5kW
SF 710 T4 2,2kW
SF 710 T4 3kW
SF 710 T6 0,55kW
SF 710 T6 0,75kW
SF 710 T6 1,1kW
SF 800 T4 2,2kW
SF 800 T4 3kW
SF 800 T4 4kW
SF 800 T6 0,75kW
SF 800 T6 1,1kW
SF 800 T6 1,5kW
SF 800 T6 2,2kW
920
1415
1430
1435
920
1415
1430
1435
1455
1455
920
920
1430
1435
1455
1455
920
920
920
1455
1455
1455
920
920
960
960
Max. Curr. (A)
230
400
690
2,60 3,46 4,33 5,89 2,60 3,46 4,33 5,89 7,97 10,74 2,60 3,46 4,33 5,89 7,97 10,74 2,60 3,46 5,11 7,97 10,74 3,46 5,11 6,41 9,01 1,5
2
2,5
3,4
1,5
2
2,5
3,4
4,6
6,2
1,5
2
2,5
3,4
4,6
6,2
1,5
2
2,95
4,6
6,2
8,2
2
2,95
3,7
5,2
4,73
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,55
0,75
1,1
1,5
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
2,2
3
4
0,75
1,1
1,5
2,2
4680
10120
11180
12480
8140
11260
13200
14900
16810
18740
9940
11090
16460
17600
19100
21650
12320
13980
15710
23760
27980
30960
18480
20670
22880
24500
68
75
78
79
74
76
77
78
80
84
80
84
87
100
103
106
98
102
105
112
130
135
139
115
120
124
56
73
75
76
63
72
73
74
75
76
63
65
78
79
81
82
65
67
68
83
84
85
70
73
74
75
R.R.P. €
400º C/2h
3.286,70
3.193,90
3.300,60
3.682,30
3.449,20
3.180,50
3.538,10
3.928,10
4.249,40
4.920,20
3.504,60
3.777,70
3.747,40
4.085,10
4.426,40
5.024,70
3.776,00
4.064,40
4.098,10
4.725,70
5.181,10
5.421,30
4.389,70
4.663,80
4.948,00
5.194,60
R.R.P. €
300º C/2h
2.958,00
2.874,50
2.970,60
3.314,10
3.104,20
2.862,50
3.184,30
3.535,30
3.824,50
4.428,20
3.154,10
3.399,90
3.372,70
3.676,60
3.983,80
4.522,20
3.398,40
3.658,00
3.688,30
4.253,10
4.663,00
4.879,20
3.950,80
4.197,40
4.453,20
4.675,10
47
SMOKE EVACUATION FANS INSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
THREE PHASE RANGE 2 SPEEDS
Model
R.P.M. max.
SF 560 T4/T8 0,75-0,15kW
SF 560 T4/T8 1,1-0,18kW
SF 560 T4/T8 1,5-0,25kW
SF 630 T4/T8 0,75-0,15kW
SF 630 T4/T8 1,1-0,18kW
SF 630 T4/T8 1,5-0,25kW
SF 630 T4/T8 2,2-0,37kW
SF 630 T4/T8 3-0,55kW
SF 710 T4/T8 1,1-0,18kW
SF 710 T4/T8 1,5-0,25kW
SF 710 T4/T8 2,2-0,37kW
SF 710 T4/T8 3-0,55kW
SF 800 T4/T8 2,2-0,37kW
SF 800 T4/T8 3-0,55kW
SF 800 T4/T8 4-0,75kW
1420/710
1430/715
1430/715
1420/710
1430/715
1430/715
1430/715
1445/725
1430/715
1430/715
1430/715
1445/725
1430/715
1445/725
1450/730
48
Max. C.(A) 400V Rated Power
kW
1500
750
2,2
2,85
3,75
2,2
2,85
3,75
5,1
6,5
2,85
3,75
5,1
6,5
5,1
6,5
8,8
0,85
0,85
1,15
0,85
0,85
1,15
1,6
2,55
0,85
1,15
1,6
2,55
1,6
2,55
3,3
0,75/0,15
1,1/0,18
1,5/0,25
0,75/0,15
1,1/0,18
1,5/0,25
2,2/0,37
3/0,55
1,1/0,18
1,5/0,25
2,2/0,37
3/0,55
2,2/0,37
3/0,55
4/0,75
Air flow
m3/h
Sound
dB (A)
Weight
Kg
10120/5060
11180/5590
12480/6240
11260/5630
13200/6600
14900/7450
16810/8400
18740/9370
16460/8230
17600/8800
19100/9550
21650/10820
23760/11880
27980/13990
30960/15480
77
80
81
78
79
80
82
86
89
102
105
108
114
132
137
73/55
75/57
76/58
72/54
73/55
74/56
75/57
76/58
78/60
79/61
81/63
82/64
83/65
84/66
85/67
R.R.P. €
400º C/2h
3.542,40
3.633,70
4.064,70
3.668,40
3.970,90
4.186,30
4.547,90
5.085,40
3.972,40
4.439,20
4.705,20
5.242,60
4.970,10
5.641,70
6.044,90
R.R.P. €
300º C/2h
3.188,20
3.270,30
3.658,30
3.301,60
3.573,80
3.767,70
4.093,10
4.576,90
3.575,10
3.995,30
4.234,70
4.718,40
4.473,10
5.077,50
5.440,40
SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory CSTB according to NF EN12101-3: 2002
CTH
Centrifugal roof 400ºC/2h
MANUFACTURING FEATURES
• Roof cowl made of polyethylene UV resistant.
• Structure, roof base support and bird protection
guard made of galvanised steel.
• High efficiency backward curved impellers of galvanised steel.
• Vertical discharge with KITV accessory.
• Standard asynchronous motor with IP-55 protection and Class F insulation. Manufactured with
standard voltages: 230V 50Hz in single phase motors, 230/400V 50Hz in three phase motors and
400V 50Hz in 2 SPEED MOTORS.
CTH (horizontal)
• Air renewal in buildings and industries.
• Industrial and professional kitchen hoods.
• Maximum continuous operation temperature:
80ºC.
UNDER REQUEST
• Security switch mounted and wired.
APPLICATIONS
Specially designed for roof installation, they are
suitable for:
• Smoke extraction.
• Smoke emergency exhaust with motor outside the
hazardous area (400ºC/2h certificate).
CTH + KITV (vertical)
ACCESSORIES
OUTSIDE
REG
RFS
INT
PE
SINGLE PHASE RANGE
Code
Model
R.P.M. max.
Max. Curr.
(A) 230
Rated Power
kW
Air flow
m3/h
Weight Kg
CTH
Weight Kg
CTH+KITV
300815900
300816000
300816100
300816200
300816300
300816400
300816500
300816600
300816700
CTH 28 M4 0,22kW
CTH 32 M4 0,22kW
CTH 36 M4 0,22kW
CTH 40 M4 0,37kW
CTH 45 M4 0,75kW
CTH 45 M6 0,25kW
CTH 50 M4 1,1kW
CTH 50 M6 0,37kW
CTH 56 M6 0,75kW
1450
1450
1450
1450
1450
950
1450
950
950
2,2
2,2
2,2
3,1
5,4
2,3
7
3
6,5
0,22
0,22
0,22
0,37
0,75
0,25
1,1
0,37
0,75
1300
1850
2700
3750
5500
3670
7500
5000
6940
22
22
24
32
38
33
43
37
62
26
26
28
40
46
41
51
45
75
R.P.M. max.
Max. C. (A)
230 400
Rated Power
kW
Air flow
m3/h
Weight Kg
CTH
Weight Kg
CTH+KITV
0,25
0,25
0,25
0,25
0,25
0,37
0,25
0,75
0,37
1,1
0,37
2,2
0,75
0,37
1,5
0,75
2,2
1,1
4
2,2
1300
1850
1240
2700
1800
3750
2500
5500
3670
7500
5000
10400
6940
5200
9900
7430
15000
11250
20000
15000
22
22
20
23
21
31
29
35
34
41
37
67
60
60
74
73
111
105
136
131
26
26
24
27
25
39
37
43
42
49
45
80
73
73
87
86
132
126
157
152
R.R.P. €
CTH
645,50
653,10
717,70
903,70
1.013,90
1.040,40
1.222,70
1.211,30
1.587,20
R.R.P. €
CTH+KITV
667,00
674,00
736,00
953,00
1.059,00
1.084,00
1.258,00
1.247,00
1.656,00
THREE PHASE RANGE
Code
300816800
300816900
300817000
300817100
300817200
300817300
300817400
300817500
300817600
300817700
300817800
300817900
300818000
300818100
300818200
300818300
300818400
300818500
300818600
300818700
Model
CTH 28 T4 0,25kW
CTH 32 T4 0,25kW
CTH 32 T6 0,25kW
CTH 36 T4 0,25kW
CTH 36 T6 0,25kW
CTH 40 T4 0,37kW
CTH 40 T6 0,25kW
CTH 45 T4 0,75kW
CTH 45 T6 0,37kW
CTH 50 T4 1,1kW
CTH 50 T6 0,37kW
CTH 56 T4 2,2kW
CTH 56 T6 0,75kW
CTH 56 T8 0,37kW
CTH 63 T6 1,5kW
CTH 63 T8 0,75kW
CTH 71 T6 2,2kW
CTH 71 T8 1,1kW
CTH 80 T6 4kW
CTH 80 T8 2,2kW
1450
1450
950
1450
950
1450
950
1450
950
1450
950
1450
950
725
950
725
950
725
950
725
0,48
0,48
0,5
0,48
0,5
0,64
0,71
1,13
0,71
1,52
0,71
2,77
1,27
0,78
2,19
1,39
3,12
1,85
5,31
3,44
0,84
0,84
0,87
0,84
0,84
1,1
1,23
1,95
1,23
2,6
1,23
4,8
2,2
1,35
3,8
2,4
5,4
3,2
9,2
5,96
R.R.P.
CTH
609,90
630,10
630,10
630,10
630,10
775,50
775,50
872,40
832,00
1.046,10
981,40
1.397,40
1.268,20
1.336,90
1.619,60
1.462,10
1.898,30
1.861,90
2.152,70
2.306,20
R.R.P.
CTH+KITV
598,00
616,00
616,00
616,00
616,00
786,00
786,00
874,00
837,00
1.030,00
972,00
1.394,00
1.278,00
1.340,00
1.594,00
1.453,00
1.934,00
1.901,00
2.162,00
2.300,00
49
SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
THREE PHASE RANGE 2 SPEEDS
Code
Model
R.P.M.
max.
Max. Curr.
(A) 400V
Rated Power
kW
Air flow
m3/h
Weight Kg
CTH
Weight Kg
CTH+KITV
300818800
300818900
300819000
300819100
300819200
300819400
300819300
300819500
300819600
300819800
300819700
300819900
300820000
300820100
300820200
300820300
300820400
300820500
300820600
CTH 32 T4/T8 0,37-0,08kW
CTH 36 T4/T8 0,37-0,08kW
CTH 40 T4/T8 0,37-0,08kW
CTH 45 T4/T8 0,8-0,2kW
CTH 45 T6/T8 0,25-0,12kW
CTH 50 T4/T6 1,1-0,3kW
CTH 50 T4/T8 1,2-0,3kW
CTH 50 T6/T8 0,37-0,2kW
CTH 50 T6/T12 0,37-0,07kW
CTH 56 T4/T6 2,2-0,7kW
CTH 56 T4/T8 2,2-0,55kW
CTH 56 T6/T8 0,75-0,37kW
CTH 56 T6/T12 0,75-0,2kW
CTH 63 T6/T8 1,5-0,75kW
CTH 63 T6/T12 1,5-0,75kW
CTH 71 T6/T8 2,2-1,3kW
CTH 71 T6/T12 2,2-0,55kW
CTH 80 T6/T8 4- 1,1kW
CTH 80 T6/T12 4-1,0kW
1450/725
1450/725
1450/725
1450/725
950/725
1450/950
1450/725
950/725
950/450
1450/950
1450/725
950/725
950/450
950/725
950/450
950/725
950/450
950/725
950/450
1,8/0,5
1,8/0,5
1,8/0,5
2/0,9
1/0,94
3/1,5
2,9/1,3
1,5/1,1
1,59/0,7
5,2/2,5
5/2
2,7/1,7
2,4/1
4/3
4,3/1,7
6,5/5
6,4/2,6
11,3/4,9
12,6/5,2
0,37/0,08
0,37/0,08
0,37/0,08
0,8/0,2
0,25/0,12
1,1/0,3
1,2/0,3
0,37/0,2
0,37/0,07
2,2/0,7
2,2/0,55
0,75/0,37
0,75/0,15
1,5/0,75
1,5/0,75
2,2/1,3
2,2/0,55
4/1,1
4/1,0
1850/930
2700/1350
3750/1880
5500/2750
3670/2750
7500/5000
7500/3750
5000/3750
5000/2500
10400/6940
10400/5200
6940/5200
6940/3470
9900/7430
9900/4950
15000/11250
15000/7500
20000/15000
20000/10000
22
23
31
36
33
44
44
37
41
71
80
62
63
93
75
127
116
145
131
26
27
39
44
41
52
52
45
49
84
93
75
73
106
88
148
137
166
152
MBC/FA
R.R.P.
CTH
R.R.P.
CTH+KITV
735,10
735,10
880,50
997,60
1.074,30
1.288,40
1.171,30
1.252,00
1.134,90
1.676,10
1.510,50
1.619,60
1.579,20
1.813,40
2.092,10
2.209,20
2.512,20
2.770,60
2.867,60
709,6
709,6
880,3
985,6
1.054,50
1.246,90
1.141,70
1.109,00
1.214,30
1.644,40
1.495,60
1.557,30
1.593,60
1.318,30
1.767,80
2.484,80
2.212,60
2.804,30
2.490,80
Centrifugal cubic fan 400ºC/2h
MANUFACTURING FEATURES
• Reinforced rolling steel sheet housings completely
welded (internally and externally) with epoxy powder
finishing coat.
• Forward curved reinforced impeller.
• Standard asynchronous squirrel-cage motor with IP55 protection and Class F insulation. Manufactured
with standard voltages: 230V 50Hz in single phase
motors and 230/400V 50Hz in three phase motors
up to 4kW, and 400/690V 50Hz for higher powers.
peratures.
• Clean air transport.
• Maximum working temperature: carried air up
to 250ºC; environment: single phase 50ºC, three
phase 60ºC.
UNDER REQUEST
• 2 speed motors.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Smoke emergency exhaust with motor outside the
hazardous area.
• Hot air exhaust in ovens or facilities with high temOUTSIDE
ACCESSORIES
RFS
INT
PE
AC
EI
BA-400
SIL-C
SIL-R
SINGLE PHASE RANGE
Code
Model
R.P.M.
max.
253310173
253300173
253380173
MBC/FA 25/10 M4 1,1kW
MBC/FA 25/10 M6 0,55kW
MBC/FA 28/11 M6 0,75kW
1400
900
900
Max. Curr. (A)
230
400
7,45
3,84
4,97
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,1
0,55
0,75
3500
1900
3600
70
62
60
63
61
67
-
R.R.P.
€
830,30
810,60
870,80
THREE PHASE RANGE
50
Code
Model
R.P.M.
max.
253310186
253300186
253360186
253370186
253380186
MBC/FA 25/10 T4 1,1kW
MBC/FA 25/10 T6 0,55kW
MBC/FA 28/11 T2 4kW
MBC/FA 28/11 T4 2,2kW
MBC/FA 28/11 T6 0,75kW
1400
900
2890
1430
910
Max. Curr. (A)
230 400
690
4,74
2,85
14,2
8,06
4
2,75
1,65
8,2
5
2,3
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,1
0,55
4
2,2
0,75
3500
1900
4000
5000
3600
70
62
81
82
60
64
63
66
75
69
R.R.P.
€
786,00
739,40
1.020,70
942,40
833,80
SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
THREE
PHASEModel
RANGE
Code
253460186
253450186
253430186
253480186
253490186
253470186
253510186
253520186
253500186
253530186
253540186
253560186
MBC/FA 31/12 T4 3kW
MBC/FA 31/12 T4 4kW
MBC/FA 31/12 T6 1,5kW
MBC/FA 35/14 T4 3kW
MBC/FA 35/14 T4 5,5kW
MBC/FA 35/14 T6 1,5kW
MBC/FA 40/16 T4 5,5kW
MBC/FA 40/16 T4 7,5kW
MBC/FA 40/16 T6 2,2kW
MBC/FA 45/18 T4 5,5kW
MBC/FA 45/18 T4 7,5kW
MBC/FA 45/18 T6 2,2kW
MBRC/FA
Max. Curr. (A)
230 400
690
R.P.M.
max.
1430
1440
940
1430
1440
940
1440
1440
940
1440
1440
940
11,7
15,2
6,9
11,7
6,9
9,7
9,7
6,8
8,8
4
6,8
12
4
12
15
5,6
12
15
5,6
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
3
4
1,5
3
5,5
1,5
5,5
7,5
2,2
5,5
7,5
2,2
5700
6800
4500
6000
8700
5500
9000
10500
7000
8000
11000
9000
72
73
66
78
79
70
78
79
71
80
82
76
72
73
71
75
79
73
87
89
86
91
93
90
6,9
6,9
8,6
6,9
8,6
-
R.R.P.
€
1.298,80
1.341,30
1.131,70
1.245,90
1.459,60
1.190,20
1.643,60
1.851,70
1.404,20
1.799,10
2.007,30
1.538,70
Backward centrifugal 400ºC/2h
MANUFACTURING FEATURES
• Reinforced rolling steel sheet housings completely
welded (internally and externally) with epoxy powder finishing coat.
• Reinforced high efficiency backward curved impeller.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V in single phase
motors and 230/400V 50Hz in three phase motors
up to 4kW, and 400/690V 50Hz for higher powers.
• Clean and slightly dusty air transport.
• Maximum working temperature: carried air up
to 250ºC; environment: single phase 50ºC, three
phase 60ºC.
UNDER REQUEST
• 2 speed motors.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Smoke emergency exhaust with motor outside the
hazardous area.
• Hot air exhaust in ovens or facilities with high temperatures.
ACCESSORIES
RFS
INT
PE
AC
EI
OUTSIDE
BA-400
SIL-C
SIL-R
SINGLE PHASE RANGE
Code
243400173
243450173
243510173
243500173
Model
MBRC/FA 40/12 M4 0,75kW
MBRC/FA 45/14 M4 1,1kW
MBRC/FA 50/16 M4 1,5kW
MBRC/FA 50/16 M6 0,75kW
R.P.M.
max.
Max. Curr. (A)
230
400
1400
1400
1400
900
5,45
7,45
9,83
4,97
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,75
1,1
1,5
0,75
5640
7000
9500
7100
72
73
76
70
71
90
74
69
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
3
0,75
1,1
1,5
0,75
3
1,5
5,5
1,5
7,5
3
8500
5640
7000
9500
7100
13500
9500
19000
12000
25500
17000
85
72
73
76
70
80
70
83
72
85
77
82
71
90
74
69
97
89
155
113
256
205
R.R.P.
€
1.610,30
1.815,30
2.006,70
2.005,60
THREE PHASE RANGE
Code
Model
R.P.M.
max.
243410186
243400186
243450186
243510186
243500186
243570186
243560186
243650186
243640186
243730186
243720186
MBRC/FA 40/12 T2 3kW
MBRC/FA 40/12 T4 0,75kW
MBRC/FA 45/14 T4 1,1kW
MBRC/FA 50/16 T4 1,5kW
MBRC/FA 50/16 T6 0,75kW
MBRC/FA 56/18 T4 3kW
MBRC/FA 56/18 T6 1,5kW
MBRC/FA 63/20 T4 5,5kW
MBRC/FA 63/20 T6 1,5kW
MBRC/FA 71/22 T4 7,5kW
MBRC/FA 71/22 T6 3kW
2870
1400
1400
1400
910
1430
940
1440
940
1440
960
Max. Curr. (A)
230 400
690
11,1
3,48
4,74
6,31
4
11,7
6,9
6,9
12,4
6,4
2,01
2,75
3,65
2,3
6,8
4
12
4
15
7,2
6,9
8,6
-
R.R.P.
€
1.765,80
1.590,30
1.802,50
2.052,30
1.968,60
2.422,50
2.237,10
3.080,60
2.728,80
3.562,10
3.213,70
51
SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
BVFC
Belt driven centrifugal cabinet fan 400ºC/2h
MANUFACTURING FEATURES
• Fans in compact thermal and soundproof cabinets with motor and transmission set outside the
airstream.
• Double inlet forward curved impeller.
• Transmission bearings specially designed for high
temperatures.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230/400V 50Hz
in three phase motors up to 4kW, and 400/690V
50Hz for higher powers.
• Industrial and professional kitchen hoods.
• Maximum working temperature: carried air
100ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• Box for outdoor applications.
• Auxiliary motor base.
• Vertical discharge. 5% additional cost.
• Transmission ratio variation.
APPLICATIONS
Designed for inline installation, indoor or outdoor
assembly, they are suitable for:
• Smoke emergency exhaust with motor outside the
hazardous area.
OUTSIDE
ACCESSORIES
RFS
INT
PE
PI
VIS
TCA
TIAC
THREE PHASE RANGE
Model
BVFC 9/9 0,37kW
BVFC 9/9 0,55kW
BVFC 9/9 0,75kW
BVFC 9/9 1,1kW
BVFC 10/10 0,37kW
BVFC 10/10 0,55kW
BVFC 10/10 0,75kW
BVFC 10/10 1,1kW
BVFC 10/10 1,5kW
BVFC 12/12 0,37kW
BVFC 12/12 0,55kW
BVFC 12/12 0,75kW
BVFC 12/12 1,1kW
BVFC 12/12 1,5kW
BVFC 12/12 2,2kW
BVFC 15/15 0,55kW
BVFC 15/15 0,75kW
BVFC 15/15 1,1kW
BVFC 15/15 1,5kW
BVFC 15/15 2,2kW
BVFC 15/15 3kW
BVFC 15/15 4kW
BVFC 18/18 1,1kW
BVFC 18/18 1,5kW
BVFC 18/18 2,2kW
BVFC 18/18 3kW
BVFC 18/18 4kW
BVFC 18/18 5,5kW
BVFC 20/20 1,5kW
BVFC 20/20 2,2kW
BVFC 20/20 3kW
BVFC 20/20 4kW
BVFC 20/20 5,5kW
BVFC 20/20 7,5kW
BVFC 22/22 1,5kW
BVFC 22/22 2,2kW
BVFC 22/22 3kW
BVFC 22/22 4kW
BVFC 22/22 5,5kW
BVFC 22/22 7,5kW
BVFC 22/22 11kW
52
230
1,94
2,69
3,48
4,74
1,94
2,69
3,48
4,74
6,31
1,94
2,69
3,48
4,74
6,31
8,06
2,69
3,48
4,74
6,31
8,06
11,7
15,2
4,74
6,31
8,06
11,7
15,2
6,31
8,06
11,7
15,2
6,31
8,06
11,7
15,2
-
Max. Curr. (A)
400
690
1,12
1,56
2,01
2,75
1,12
1,56
2,01
2,75
3,65
1,12
1,56
2,01
2,75
3,65
5
1,56
2,01
2,75
3,65
5
6,8
8,8
2,75
3,65
5
6,8
8,8
12
3,65
5
6,8
8,8
12
15
3,65
5
6,8
8,8
12
15
20,9
6,9
6,9
8,6
6,9
8,6
12,02
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,37
0,55
0,75
1,1
0,37
0,55
0,75
1,1
1,5
0,37
0,55
0,75
1,1
1,5
2,2
0,55
0,75
1,1
1,5
2,2
3
4
1,1
1,5
2,2
3
4
5,5
1,5
2,2
3
4
5,5
7,5
1,5
2,2
3
4
5,5
7,5
1,5
2960
3230
3475
4215
3139
3588
4036
4485
5382
4275
4875
5250
6075
6700
7776
5915
6400
7760
8500
9450
10600
10924
11100
12100
13000
15800
16700
17764
13000
16000
18000
20000
21900
24500
15500
17625
20625
23125
25800
28000
32500
70
73
77
80
68
70
73
77
80
64
67
70
73
76
79
62
64
67
70
74
77
80
67
72
74
77
79
84
74
76
77
80
82
84
73
76
79
82
85
87
90
40
42
43
46
47
49
50
54
59
69
71
72
75
79
87
90
91
94
95
103
105
110
127
131
139
141
146
160
252
255
256
261
275
280
280
285
287
291
297
304
316
R.R.P.
€
1.124,60
1.145,30
1.172,60
1.214,30
1.178,00
1.201,90
1.226,50
1.298,60
1.335,00
1.338,10
1.362,00
1.386,20
1.437,10
1.470,50
1.551,90
1.678,90
1.741,70
1.766,80
1.818,70
1.912,30
1.927,50
2.079,30
2.138,80
2.165,00
2.289,00
2.323,70
2.443,40
2.629,60
3.443,30
3.598,90
3.657,80
3.816,60
4.105,80
4.398,60
3.811,30
3.855,40
3.936,50
4.095,20
4.366,80
4.723,10
5.329,80
SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
Model
230
BVFC 25/25 2,2kW
BVFC 25/25 3kW
BVFC 25/25 4kW
BVFC 25/25 5,5kW
BVFC 25/25 7,5kW
BVFC 25/25 11kW
BVFC 30/28 2,2kW
BVFC 30/28 3kW
BVFC 30/28 4kW
BVFC 30/28 5,5kW
BVFC 30/28 7,5kW
BVFC 30/28 11kW
BVFC 30/28 15kW
8,06
11,7
15,2
8,06
11,7
15,2
-
Max. Curr. (A)
400
690
5
6,8
8,8
12
15
20,9
5
6,8
8,8
12
15
20,9
27,9
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
2,2
3
4
5,5
7,5
1,5
2,2
3
4
5,5
7,5
11
15
20000
24900
27400
30000
33000
38000
22500
27500
34000
39000
43000
48500
54900
72
75
77
81
85
88
73
76
77
81
83
86
88
329
331
336
353
357
380
410
418
426
438
444
458
462
6,9
8,6
12,02
6,9
8,6
12,02
16,04
R.R.P.
€
4.567,90
4.666,70
4.772,50
4.931,20
5.269,80
5.866,00
5.001,80
5.111,10
5.252,20
5.470,90
5.855,40
6.433,90
6.984,10
THREE PHASE RANGE 2 SPEEDS
Model
BVFC 9/9 T4/T8 0,60-0,12kW
BVFC 9/9 T4/T8 0,85-0,20kW
BVFC 9/9 T4/T8 1,40-0,30kW
BVFC 10/10 T4/T8 0,60-0,12kW
BVFC 10/10 T4/T8 0,85-0,20kW
BVFC 10/10 T4/T8 1,40-0,30kW
BVFC 10/10 T4/T8 1,80-0,40kW
BVFC 12/12 T4/T8 0,60-0,12kW
BVFC 12/12 T4/T8 0,85-0,20kW
BVFC 12/12 T4/T8 1,40-0,30kW
BVFC 12/12 T4/T8 1,80-0,40kW
BVFC 12/12 T4/T8 2,2-0,60kW
BVFC 15/15 T4/T8 0,60-0,12kW
BVFC 15/15 T4/T8 0,85-0,20kW
BVFC 15/15 T4/T8 1,40-0,30kW
BVFC 15/15 T4/T8 1,80-0,40kW
BVFC 15/15 T4/T8 2,20-0,60kW
BVFC 15/15 T4/T8 2,80-0,70kW
BVFC 15/15 T4/T8 4-1kW
BVFC 18/18 T4/T8 1,40-0,30kW
BVFC 18/18 T4/T8 1,80-0,40kW
BVFC 18/18 T4/T8 2,20-0,60kW
BVFC 18/18 T4/T8 2,80-0,70kW
BVFC 18/18 T4/T8 4-1kW
BVFC 18/18 T4/T8 6,50-1,80kW
Max. Curr. (A)
400V
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,72/0,75
2,33/0,88
3,63/1,21
1,72/0,75
2,33/0,88
3,63/1,21
4,44/1,43
1,72/0,75
2,33/0,88
3,63/1,21
4,44/1,43
5,34/2,18
1,72/0,75
2,33/0,88
3,63/1,21
4,44/1,43
5,34/2,18
6,3/2,42
9,2/3,7
3,63/1,21
4,44/1,43
5,34/2,18
6,3/2,42
9,2/3,7
13,9/5,62
0,6/0,12
0,85/0,2
1,4/0,3
0,6/0,12
0,85/0,2
1,4/0,3
1,8/0,4
0,6/0,12
0,85/0,2
1,4/0,3
1,8/0,4
2,2/0,6
0,6/0,12
0,85/0,2
1,4/0,3
1,8/0,4
2,2/0,6
2,8/0,7
4/1
1,4/0,3
1,8/0,4
2,2/0,6
2,8/0,7
4/1
6,5/1,8
3500/1750
3800/1900
4400/2200
4000/2000
4450/2225
5100/2550
5550/2775
5400/2700
5900/2950
6800/3400
7400/3700
8400/4200
5500/2750
6000/3000
7850/3925
8700/4350
9850/4925
10000/5000
11500/5750
11000/5500
12000/6000
14100/7050
15800/7900
16500/8250
20000/10000
66/50
67/53
71/55
64/50
68/52
69/54
72/56
63/48
66/50
69/63
70/55
73/58
58/44
59/44
64/48
65/50
68/53
69/54
70/55
58/43
60/45
65/49
66/50
67/51
71/56
45
47
49
53
54
55
61
76
78
79
83
85
92
93
98
100
104
106
110
130
135
149
151
155
169
R.R.P.
€
1.374,30
1.393,20
1.442,70
1.442,30
1.457,20
1.542,90
1.586,10
1.634,40
1.647,00
1.707,50
1.747,20
1.843,80
2.014,70
2.069,30
2.099,20
2.160,90
2.272,10
2.290,10
2.470,50
2.541,20
2.572,20
2.719,60
2.760,80
2.903,10
3.124,30
53
SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
SUST
Belt driven centrifugal cabinet fan 400ºC/2h
MANUFACTURING FEATURES
• Single inlet BST range fans, 400ºC/2h.
• Fan assembled on antivibration mountings.
• Supplied with motor, pulleys and belts.
• Interchangeable panels to allow different fan positions.
• Gland connection included.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230/400V 50Hz
in three phase motors up to 4kW, and 400/690V
50Hz for higher powers.
APPLICATIONS
Designed for inline installation, indoor or outdoor
assembly, they are suitable for:
• Smoke emergency exhaust with motor outside the
hazardous area.
• Industrial and professional kitchen hoods.
• Maximum working temperature: carried air 80ºC;
environment 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
OUTSIDE
ACCESSORIES
RFS
INT
PE
THREE PHASE RANGE
Max. Curr. (A)
230
400
690
Model
SUST 12/6 0,55kW
SUST 12/6 0,75kW
SUST 12/6 1,1kW
SUST 12/6 1,5kW
SUST 12/6 2,2kW
SUST 15/7 0,55kW
SUST 15/7 0,75kW
SUST 15/7 1,1kW
SUST 15/7 1,5kW
SUST 15/7 2,2kW
SUST 15/7 3kW
SUST 15/7 4kW
SUST 18/9 1,1kW
SUST 18/9 1,5kW
SUST 18/9 2,2kW
SUST 18/9 3kW
SUST 18/9 4kW
SUST 18/9 5,5kW
SUST 20/10 1,5kW
SUST 20/10 2,2kW
SUST 20/10 3kW
SUST 20/10 4kW
SUST 20/10 5,5kW
SUST 20/10 7,5kW
SUST 22/11 2,2kW
SUST 22/11 3kW
SUST 22/11 4kW
SUST 22/11 5,5kW
SUST 22/11 7,5kW
SUST 22/11 11kW
SUST 25/13 2,2kW
SUST 25/13 3kW
SUST 25/13 4kW
SUST 25/13 5,5kW
SUST 25/13 7,5kW
SUST 25/13 11kW
SUST 25/13 15kW
SUST 30/14 3kW
SUST 30/14 4kW
SUST 30/14 5,5kW
SUST 30/14 7,5kW
SUST 30/14 11kW
SUST 30/14 15kW
54
-
2,69
3,48
4,74
6,31
8,06
2,69
3,48
4,74
6,31
8,06
11,7
15,2
4,74
6,31
8,06
11,7
15,2
6,31
8,06
11,7
15,2
8,06
11,7
15,2
8,06
11,7
15,2
11,7
15,2
-
1,56
2,01
2,75
3,65
5
1,56
2,01
2,75
3,65
5
6,8
8,8
2,75
3,65
5
6,8
8,8
12
3,65
5
6,8
8,8
12
15
5
6,8
8,8
12
15
20,9
5
6,8
8,8
12
15
20,9
27,9
6,8
8,8
12
15
20,9
27,9
6,9
6,9
8,6
6,9
8,6
12,02
6,9
8,6
12,02
16,04
6,9
8,6
12,02
16,04
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,55
0,75
1,1
1,5
2,2
0,55
0,75
1,1
1,5
2,2
3
4
1,1
1,5
2,2
3
4
5,5
1,5
2,2
3
4
5,5
7,5
2,2
3
4
5,5
7,5
11
2,2
3
4
5,5
7,5
11
15
3
4
5,5
7,5
11
15
2900
3300
3900
4200
4800
3600
4800
6000
6500
7800
8500
9500
5000
6000
7500
8000
9000
10000
11000
13000
14000
15000
16500
19000
15000
16000
18000
20000
22000
23000
16500
19000
21000
24000
26000
29000
29500
18000
22000
25000
30000
33000
36000
72
75
78
80
85
68
74
72
76
82
84
87
82
83
87
88
89
92
79
83
86
88
92
94
77
79
82
85
87
92
71
74
76
78
83
86
89
74
76
78
82
85
87
73
74
77
80
85
91
92
95
98
103
106
109
110
114
119
122
125
140
203
208
211
214
227
235
219
222
225
238
246
273
251
254
257
270
278
305
324
328
331
344
352
379
398
R.R.P.
€
1.425,60
1.440,80
1.524,80
1.575,20
1.635,40
1.557,80
1.570,60
1.654,60
1.705,10
1.765,40
1.898,40
2.154,70
1.825,50
1.876,00
1.936,20
2.069,50
2.540,70
2.805,10
2.900,40
2.960,60
3.093,70
3.564,90
3.829,20
4.388,70
3.191,40
3.324,30
3.795,80
4.046,50
4.548,30
4.977,90
3.339,20
3.549,10
4.020,30
4.271,10
4.773,00
5.202,70
6.498,80
4.164,10
4.547,40
4.798,50
5.578,50
5.729,20
7.026,00
SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
BOX BSTBF
Belt driven backward centrifugal cabinet fan 400ºC/2h
MANUFACTURING FEATURES
• Single inlet BST range fans, BSTB 400ºC/2h
• Fan assembled on antivibration mountings.
• Supplied with motor, pulleys and belts.
• Gland connection included.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230/400V 50Hz
in three phase motors up to 4kW, and 400/690V
50Hz for higher powers.
• Maximum working temperature: carried air
130ºC; environment 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Inlet in the opposite side, vertical inlet, blind inlet
panel.
• Variation of the transmission ratio.
• Sandwich insulation.
APPLICATIONS
Designed for inline installation, indoor or outdoor
assembly, they are suitable for:
• Smoke emergency exhaust with motor outside the
hazardous area.
• Industrial and professional kitchen hoods.
ACCESSORIES
RFS
INT
OUTSIDE
PE
THREE PHASE RANGE
Model
BOX BSTBF 355 0,37kW
BOX BSTBF 355 0,55kW
BOX BSTBF 355 0,75kW
BOX BSTBF 355 1,1kW
BOX BSTBF 355 1,5kW
BOX BSTBF 355 2,2kW
BOX BSTBF 355 3kW
BOX BSTBF 400 0,55kW
BOX BSTBF 400 0,75kW
BOX BSTBF 400 1,1kW
BOX BSTBF 400 1,5kW
BOX BSTBF 400 2,2kW
BOX BSTBF 400 3kW
BOX BSTBF 400 4kW
BOX BSTBF 450 0,75kW
BOX BSTBF 450 1,1kW
BOX BSTBF 450 1,5kW
BOX BSTBF 450 2,2kW
BOX BSTBF 450 3kW
BOX BSTBF 450 4kW
BOX BSTBF 450 5,5kW
BOX BSTBF 450 7,5kW
BOX BSTBF 500 1,1kW
BOX BSTBF 500 1,5kW
BOX BSTBF 500 2,2kW
BOX BSTBF 500 3kW
BOX BSTBF 500 4kW
BOX BSTBF 500 5,5kW
BOX BSTBF 500 7,5kW
BOX BSTBF 560 1,5kW
BOX BSTBF 560 2,2kW
BOX BSTBF 560 3kW
BOX BSTBF 560 4kW
BOX BSTBF 560 5,5kW
BOX BSTBF 560 7,5kW
BOX BSTBF 560 11kW
230
Max. Curr. (A)
400
690
Rated Power
kW
Air flow
m3/h
1,94
2,69
3,48
4,74
6,31
8,06
11,7
2,69
3,48
4,74
6,31
8,06
11,7
15,2
3,48
4,74
6,31
8,06
11,7
15,2
4,74
6,31
8,06
11,7
15,2
6,31
8,06
11,7
15,2
-
1,12
1,56
2,01
2,75
3,65
5
6,8
1,56
2,01
2,75
3,65
5
6,8
8,8
2,01
2,75
3,65
5
6,8
8,8
12
15
2,75
3,65
5
6,8
8,8
12
15
3,65
5
6,8
8,8
12
15
20,9
6,9
8,6
6,9
8,6
6,9
8,6
12,02
0,37
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
1,5
2,2
3
4
0,75
1,1
1,5
2,2
3
4
5,5
7,5
1,1
1,5
2,2
3
4
5,5
7,5
1,5
2,2
3
4
5,5
7,5
11
3370
3850
4330
5050
5530
6010
6980
4350
5020
5360
6030
7370
8040
9460
5990
6490
7490
8490
9490
10490
11490
12980
7490
8850
9530
10890
12260
13620
14980
9550
11290
12160
13020
14760
16500
18230
R.R.P.
€
1.696,30
1.724,90
1.741,60
1.745,20
1.797,90
1.827,00
1.850,60
1.897,20
1.908,80
1.915,30
1.961,30
1.998,60
2.029,30
2.095,60
2.173,80
2.179,30
2.226,30
2.248,20
2.296,00
2.355,80
2.511,00
2.674,80
2.489,80
2.539,90
2.558,80
2.604,70
2.663,50
2.817,60
3.001,50
3.239,20
3.216,80
3.279,10
3.411,30
3.368,80
3.707,90
3.899,50
55
SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory APPLUS according to CTE-2006.D.C.89/106CEE
Model
BOX BSTBF 630 2,2kW
BOX BSTBF 630 3kW
BOX BSTBF 630 4kW
BOX BSTBF 630 5,5kW
BOX BSTBF 630 7,5kW
BOX BSTBF 630 11kW
BOX BSTBF 630 15kW
BOX BSTBF 710 3kW
BOX BSTBF 710 4kW
BOX BSTBF 710 5,5kW
BOX BSTBF 710 7,5kW
BOX BSTBF 710 11kW
BOX BSTBF 710 15kW
BOX BSTBF 710 18,5kW
56
230
Max. Curr. (A)
400
690
Rated Power
kW
Air flow
m3/h
8,06
11,7
15,2
11,7
15,2
-
5
6,8
8,8
12
15
20,9
27,9
6,8
8,8
12
15
20,9
27,9
33
6,9
8,6
12,02
16,04
6,9
8,6
12,02
16,04
18,98
2,2
3
4
5,5
7,5
11
15
3
4
5,5
7,5
11
15
18,5
12720
13990
15260
16540
19080
21630
22900
18370
18370
20200
22960
25710
27550
31220
R.R.P.
€
3.583,10
3.673,70
3.779,60
3.742,00
3.417,10
4.304,40
4.598,60
4.673,90
4.788,10
4.730,50
4.946,50
5.317,80
5.588,60
5.881,20
DOMESTIC RANGE
DOMESTIC RANGE
Axial and centrifugal exhaust fans with discharge at a single pipe, a ‘shunt’ duct or directly outside. Made of plastic, shock proof and thermal resistants. In compliance with the security standards of the thermal double insulation. Self greased bearings. Automatic shutter in standard series.
ACCESSORIES UNDER REQUEST: applicable to all models of the DCB, DB and DAL ranges.
Gravity guard
Fixing rings
Backdraft damper
AXIAL EXTRACTORS
Model
DHS 160
DHS 190
DHS 225
DHS 300
DHS 350
DHS 400
R.P.M. max.
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
Diameter
mm
1750
1500
1150
1050
1300
1400
0,020
0,030
0,040
0,050
0,110
0,250
450
700
900
1450
1850
3150
40
42
44
47
52
55
1,2
1,7
3
3,4
4,3
7,4
160
190
225
300
350
400
DHS 160 /190 / 225 / 300
R.R.P.
€
54,60
58,60
73,30
103,60
254,40
380,50
DHS 350 / 400
CENTRIFUGAL BATH EXTRACTORS
Model
DCB-100
DCB 100 TIMER
DCB-250
DCB 250 TIMER
R.P.M. max.
Rated Power
kW
Air flow
m3/h
2300
2300
2500
2500
0,025
0,025
0,045
0,045
130
130
270
270
Ps
mmH2O
13
13
23
23
Sound
dB (A)
Weight
Kg
Diameter
mm
49
49
52
52
1
1
1,65
1,65
100
100
100/120*
100/120*
R.R.P.
€
74,90
104,90
151,80
213,20
* Adapter included that allows both diameters.
DCB-250 / 250 TIMER
DCB-100 / 100TIMER
57
DOMESTIC RANGE
AXIAL BATH EXTRACTORS
Model
DB-8
DB-10
DB-12
DB-15
R.P.M.
max.
Rated Pow.
kW
Air flow
m3/h
2500
2500
2450
2100
0,015
0,015
0,02
0,025
70
98
190
320
Ps
mmH2O
Sound
dB (A)
Weight
Kg
Diameter
mm
39
41
43
43
39
41
43
43
90
100
120
150
3
3
5
8
R.R.P.
€
36,60
36,80
51,80
69,60
Exclusive mounting system without screws. Backdraft shutter included..
UNDER REQUEST: DB TIMER models.
DELUXE SERIES AXIAL BATH EXTRACTORS
Model
R.P.M. max.
Rated Power
kW
Air flow
m3/h
DAL 10 STANDARD
DAL 10 TIMER
DAL 12 STANDARD
DAL 12 TIMER
DAL 15 STANDARD
DAL 15 TIMER
DAL 10 INOX
DAL 10 INOX TIMER
DAL 12 INOX
DAL 12 INOX TIMER
DAL 15 INOX
DAL 15 INOX TIMER
2500
2500
2450
2450
2100
2100
2500
2500
2450
2450
2100
2100
0,015
0,015
0,020
0,020
0,025
0,025
0,015
0,015
0,020
0,020
0,025
0,025
98
98
190
190
320
320
98
98
190
190
320
320
Ps
mmH2O
3
3
5
5
8
8
3
3
5
5
8
8
Sound
dB (A)
Weight
Kg
Diameter
mm
38
38
40
40
42
42
38
38
40
40
42
42
0,64
0,64
0,84
0,84
1,02
1,02
0,66
0,66
0,87
0,87
1,04
1,04
100
100
120
120
150
150
100
100
120
120
150
150
R.R.P.
€
49,80
83,30
67,80
103,00
91,30
128,80
62,40
102,80
91,30
128,80
109,20
150,10
KITCHEN EXTRACTORS
Code
300523100
300403100
300655900
300656000
DG-400P
58
Model
DG-400 P
DG-600
DG-600 2V
DG-750
R.P.M. max.
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
Diameter
mm
2200
1180
1185
1200
0,060
0,105
0,105
0,125
290
480
420/600
700
52
50
52
49
2,02
4,8
4
5
110
110
118
118
DG-600
DG-600 2V
R.R.P.
€
83,60
132,50
135,80
150,90
DG-750
INDUSTRIAL VENTILATION
AXIAL FANS
LONG CASED AXIAL FANS
CENTRIFUGAL LOW PRESSURE FANS
CENTRIFUGAL MEDIUM PRESSURE FANS
CENTRIFUGAL HIGH PRESSURE FANS
www.casals.tv
59
AXIAL FANS
HJEPA
Square wall plate fan
MANUFACTURING FEATURES
• Polypropylene square plate reinforced with fiberglass. High resistance against corrosion.
• Aluminium sheet impeller.
• Supplied with motor support and protection guard
according to the UNE-EN 294 standard.
• Shadow coil asynchronous motor with Electromagnetic Compatibility Certification (EMC) according to the EN 55014, EN 61000-3-2 (95) and EN
61000-3-3 (95) Standards; rated Class F isolation
and IP-42 protection according to the DIN40050
standard.
ACCESSORIES
REG
INT
PE
RP0
PC
APPLICATIONS
Designed for wall assembly, they are suitable for:
• Air renewal in all kind of closed environments.
• Maximum working temperature: 50ºC.
PCP
SINGLE PHASE RANGE
Code
265200103
265250103
265310103
265350103
60
Model
HJEPA 20 M4
HJEPA 25 M4
HJEPA 30 M4
HJEPA 35 M4
R.P.M. max.
1300
1300
1300
1300
Max. Curr. (A)
230
400
0,2
0,35
0,55
0,7
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,03
0,056
0,077
0,075
500
900
1350
1825
37
42
47
50
1,5
2,5
3,5
4
R.R.P.
€
95,20
110,30
134,00
160,10
AXIAL FANS
HJBPA
Square wall plate fan, variable pitch blades
MANUFACTURING FEATURES
• Polypropylene square plate reinforced with fiberglass. High resistance against corrosion.
• Model 62 only available in steel sheet plate and
epoxy powder finishing coat.
• Variable pitch angle polyamide impeller reinforced with fiberglass.
• Supplied with motor support and protection guard
according to the ROHS 2002/95/EC Directive (Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipments).
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Terminal
board with IP-65 protection. Manufactured with
standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors.
ACCESSORIES
REG
RFS
INT
PE
RP0
APPLICATIONS
Designed for wall assembly, they are suitable for:
• Air renewal in buildings and industries.
• Maximum working temperature: single phase
50ºC, three phase 60ºC.
UNDER REQUEST
• B form impeller (air flow from impeller to motor),
100% reversible impeller and cast aluminium impeller. 5% additional cost.
• 60Hz fans and special voltages.
• Thermal protection.
PC
PCP
SINGLE PHASE RANGE
Code
268300103
268310103
268320103
268350103
268360103
268370103
268400103
268410103
268420103
268450106
266350103
266360103
300398900
266400103
266410103
300176300
266450103
266460103
Model
HJBPA 30 M2/H 0,25kW
HJBPA 30 M4/L 0,1kW
HJBPA 30 M4/H 0,12kW
HJBPA 35 M2/H 0,37kW
HJBPA 35 M4/L 0,1kW
HJBPA 35 M4/H 0,12kW
HJBPA 40 M4/L 0,12kW
HJBPA 40 M4/H 0,25kW
HJBPA 40 M6/H 0,12kW
HJB 45 M4/L 0,25kW
HJB 45 M4/H 0,37kW
HJB 45 M6/H 0,12kW
HJB 50 M4/L 0,37kW
HJB 50 M4/H 0,55kW
HJB 50 M6/H 0,25kW
HJB 56 M4/L 0,55kW
HJB 56 M4/H 1,1kW
HJB 56 M6/H 0,25kW
R.P.M. max.
2800
1370
1400
2800
1370
1400
1400
1400
900
1400
1400
900
1400
1400
900
1400
1400
900
Max. Curr. (A)
230
400
2,73
0,83
1,1
2,73
0,83
1,1
1,1
1,1
1,05
2,02
2,77
1,05
2,77
4,25
2,07
4,25
7,45
2,07
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,25
0,1
0,12
0,37
0,1
0,12
0,12
0,25
0,12
0,25
0,37
0,12
0,37
0,55
0,25
0,55
1,1
0,25
3600
1950
2400
6000
2900
3400
4000
5200
3900
5900
7300
5400
7200
10200
6450
11000
13000
7900
72
51
54
75
55
59
60
62
54
64
65
58
66
69
60
71
73
61
6
5,5
5,6
7,5
6,5
6,6
7,5
7,7
9
12
12,5
13
14
15
18
19
22
19
R.R.P.
€
276,60
263,50
292,20
312,10
287,70
301,20
291,30
313,60
341,40
418,90
425,00
415,90
484,70
504,30
475,00
516,60
541,80
526,90
THREE PHASE RANGE
Code
Model
R.P.M. max.
268300106
268310106
268320106
268350106
268360106
268370106
268400106
268410106
268420106
300191800
266350106
266360106
300160200
266400106
266410106
300172600
266450106
266460106
HJBPA 30 T2/H 0,25kW
HJBPA 30 T4/L 0,1kW
HJBPA 30 T4/H 0,12kW
HJBPA 35 T2/H 0,37kW
HJBPA 35 T4/L 0,1kW
HJBPA 35 T4/H 0,12kW
HJBPA 40 T4/L 0,12kW
HJBPA 40 T4/H 0,25kW
HJBPA 40 T6/H 0,12kW
HJB 45 T4/L 0,25kW
HJB 45 T4/H 0,37kW
HJB 45 T6/H 0,12kW
HJB 50 T4/L 0,37kW
HJB 50 T4/H 0,55kW
HJB 50 T6/H 0,25kW
HJB 56 T4/L 0,55kW
HJB 56 T4/H 1,1kW
HJB 56 T6/H 0,25kW
2800
1400
1400
2800
1400
1400
1400
1400
850
1400
1400
850
1400
1400
900
1400
1400
900
Max. Curr. (A)
230
400
1,65
0,67
0,84
1,65
0,67
0,84
0,84
1,44
1,08
1,44
1,94
1,08
1,94
2,69
1,51
2,69
4,74
1,51
0,95
0,39
0,48
0,95
0,39
0,48
0,48
0,83
0,62
0,83
1,12
0,62
1,12
1,56
0,87
1,56
2,75
0,87
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,25
0,1
0,12
0,37
0,1
0,12
0,12
0,25
0,12
0,25
0,37
0,12
0,37
0,55
0,25
0,55
1,1
0,25
3600
1950
2400
6000
2900
3400
4000
5200
3900
5900
7300
5400
7200
10200
6450
11000
13000
7900
72
51
54
75
55
59
60
62
54
64
65
58
66
69
60
71
73
61
6
5,5
5,6
7,5
6,5
6,6
7,5
7,7
9
12
12,5
13
14
15
18
19
22
19
R.R.P.
€
266,00
256,90
267,20
305,80
285,50
285,50
285,30
305,20
336,90
408,80
417,20
404,70
480,40
482,00
466,60
483,80
501,30
476,70
61
AXIAL FANS
HJRE
Square wall plate, compact external rotor motor
MANUFACTURING FEATURES
• Steel sheet frame and impeller with epoxy powder
finishing coat.
• Supplied with motor support and protection guard
according to the UNE-EN 20-359-74 standard. In
compliance with the ROHS 2002/95/EC Directive
(Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipments).
• External rotor motor with IP-44 protection. Manufactured with standard voltages: 230V 50Hz in
single phase motors and 230/400V 50Hz in three
phase motors.
ACCESSORIES
REG
RFS
INT
PE
PC
APPLICATIONS
Designed for wall assembly, they are suitable for:
• Air renewal in buildings and industries.
• Maximum working temperature: single phase
50ºC, three phase 55ºC.
PCP
SINGLE PHASE RANGE
Model
HJRE 35 M4
HJRE 40 M4
HJRE 45 M4
HJRE 50 M4
HJRE 56 M4
R.P.M. max.
1370
1350
1390
1360
1340
Max. Curr. (A)
230
400
0,68
0,81
1
1,7
2,23
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,15
0,18
0,25
0,42
0,53
3278
4510
6248
7150
9350
52
57
61
63
68
4,7
6,1
6,9
9,5
10,5
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,18
0,21
0,38
0,38
4510
6248
7150
9350
57
61
63
68
6,1
6,9
9,5
10,5
R.R.P.
€
255,60
259,00
372,40
430,80
459,10
THREE PHASE RANGE
Model
HJRE 40 T4
HJRE 45 T4
HJRE 50 T4
HJRE 56 T4
62
R.P.M. max.
1380
1370
1370
1350
Max. Curr. (A)
230
400
0,43
0,52
0,97
0,97
0,74
0,9
1,68
1,68
R.R.P.
€
253,40
363,30
426,90
429,90
AXIAL FANS
HJB
Wall axial belt driven fan for high flowrates and low RPM
MANUFACTURING FEATURES
• Casing made of galvanised steel sheet.
• Equipped with gravity shutter.
• Aluminium impeller.
• Protection guard on pulley area.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and class F insulation. Manufactured with standard voltage: 230/400V 50Hz.
ACCESSORIES
RFS
INT
APPLICATIONS
Designed for wall assembly, they are suitable for:
• Air renewal in buildings and industries.
• Farms and greenhouses.
• Maximum working temperature: 50ºC.
PE
SERIE TRIFÁSICA
Code
266790106
266820106
266810162
Model
R.P.M.
max.
HJB 80 T4 0,55kW
HJB 100 T4 0,75kW
HJB 120 T4 1,1kW
450
450
450
Max. Curr. (A)
230
400
2,8
3,5
4,8
1,6
2
2,8
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,55
0,75
1,1
30000
40000
45000
60
61
63
58
68
88
R.R.P.
€
754,00
873,00
972,20
63
AXIAL FANS
HA
Wall plate compact, retro design
MANUFACTURING FEATURES
• Compact housing made of L-2630 aluminium
(Al.8 Si 3 Cu), protected against corrosion with
epoxy powder finishing coat.
• Polyamide impeller with fixed pitch angle reinforced with fiberglass.
• Standard asynchronous squirrel-cage motor with
IP-54 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors.
ACCESSORIES
REG
RFS
INT
PE
RP0
RP1
APPLICATIONS
Designed for wall assembly, they are suitable for:
• Air renewal in buildings and industries.
• Maximum working temperature: single phase
50ºC, three phase 60ºC.
PC
PCP
SINGLE PHASE RANGE
Code
Model
R.P.M. max.
262070120
262250103
262100120
262280103
262310103
262500103
HA 24 M2 0,06kW
HA 24 M4 0,05kW
HA 28 M2 0,08kW
HA 28 M4 0,06kW
HA 35 M4 0,08kW
HA 35 M6 0,05kW
2870
1470
2800
1360
1370
970
Max. Curr. (A)
230
400
0,6
0,5
0,9
0,59
0,9
0,7
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,06
0,05
0,08
0,06
0,08
0,05
2100
980
2500
1500
3000
2000
65
50
70
52
60
47
3,5
3,5
3,5
3,5
5,5
5,5
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,06
0,05
0,08
0,06
0,37
0,08
0,05
2100
980
2500
1500
5500
3000
2000
65
50
70
52
77
60
47
3,5
3,5
3,5
3,5
6,5
5,5
5,5
R.R.P.
€
219,00
221,80
224,40
227,30
271,10
302,50
THREE PHASE RANGE
Code
262070106
262250106
262100106
262280106
262140106
262310106
262500106
64
Model
HA 24 T2 0,06kW
HA 24 T4 0,05kW
HA 28 T2 0,08kW
HA 28 T4 0,06kW
HA 35 T2 0,37kW
HA 35 T4 0,08kW
HA 35 T6 0,05kW
R.P.M. max.
2900
1480
2840
1400
2800
1400
980
Max. Curr. (A)
230
400
0,45
0,5
0,6
0,49
1,4
0,035
0,8
0,26
0,3
0,32
0,28
0,8
0,2
0,45
R.R.P.
€
213,40
214,00
218,80
219,30
256,00
261,60
293,70
AXIAL FANS
HB-HBA
Wall plate, variable pitch blades
MANUFACTURING FEATURES
• Plate axial fan with circular reinforced frame.
• Motor-impeller modular assembly for complete
versatility.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase,
motors up to 4kW and 400/690V 50Hz for higher
powers.
• HB: polyamide impeller with variable pitch angle
reinforced with fiberglass
• HBA: cast aluminium impeller with variable pitch
angle.
HB
APPLICATIONS
Designed for wall or duct installation, they are suitable for:
• Air renewal in buildings and industries.
• Maximum working temperature: single phase
50ºC, three phase 60ºC.
UNDER REQUEST
• B form impeller (air flow from impeller to motor),
100% reversible impeller. 5% additional cost.
• 60Hz fans and special voltages.
• Hot-dipped galvanised or stainless steel housing.
• Optional square plate in circular frame.
HBA
ACCESSORIES
REG
RFS
INT
PE
RP0
RP1
PC
PCP
MC HB
SINGLE PHASE RANGE
Code
Model
R.P.M. max.
260300x03
260310x03
260350x03
260360x03
260410x03
260470x03
260480x03
260500x03
260510x03
260560x03
260600x03
260680x03
260760x03
HB 30 M2 0,37kW
HB 30 M4 0,12kW
HB 35 M2 0,37kW
HB 35 M4 0,12kW
HB 40 M4 0,25kW
HB 45 M4 0,37kW
HB 45 M6 0,12kW
HB 50 M4 0,55kW
HB 50 M6 0,25kW
HB 56 M4 0,55kW
HB 56 M6 0,25kW
HB 63 M6 0,37kW
HB 71 M6 0,55kW
2800
1400
2800
1400
1400
1400
900
1400
900
1400
900
900
900
Max. Curr. (A) Rated Power
kW
230
400
2,73
1,1
2,73
1,1
2,02
2,77
1,05
4,25
2,69
4,25
2,07
2,69
3,84
-
Air flow
m3/h
Sound
dB (A)
Weight
Kg
3100
1550
5200
2900
4700
7500
5200
10065
6000
11330
8680
11440
15400
71
56
77
60
64
68
54
70
58
73
61
63
68
7
7
11
10
17
15
14
17
18
21
19
24
29
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,37
0,12
0,37
0,12
1,10
0,25
1,50
2,20
0,37
0,12
0,55
0,25
0,55
0,75
1,10
1,50
3100
1550
5200
2900
8500
4700
12100
13500
7500
5200
10065
6000
11330
12650
13970
15600
71
56
77
60
84
64
85
87
67
54
70
58
73
74
75
76
5
4
10
9
15
11
23
26
15
14
17
18
19
22
26
28
0,37
0,12
0,37
0,12
0,25
0,37
0,12
0,55
0,25
0,55
0,25
0,37
0,55
R.R.P. €
Polyamide
365,40
359,70
366,50
353,70
410,90
404,10
361,60
453,30
517,10
453,30
478,40
540,70
641,10
R.R.P. €
Aluminium
416,50
410,10
417,80
403,20
468,40
476,90
426,70
534,90
610,20
534,90
564,50
638,00
756,40
THREE PHASE RANGE
Code
Model
R.P.M.
max.
260300x06
260310x06
260350x06
260360x06
260400x06
260410x06
260450x06
260460x06
260470x06
260480x06
260500x06
260510x06
260560x06
260570x06
260580x06
260590x06
HB 30 T2 0,37kW
HB 30 T4 0,12kW
HB 35 T2 0,37kW
HB 35 T4 0,12kW
HB 40 T2 1,1kW
HB 40 T4 0,25kW
HB 45 T2 1,5kW
HB 45 T2 2,2kW
HB 45 T4 0,37kW
HB 45 T6 0,12kW
HB 50 T4 0,55kW
HB 50 T6 0,25kW
HB 56 T4 0,55kW
HB 56 T4 0,75kW
HB 56 T4 1,1kW
HB 56 T4 1,5kW
2800
1400
2800
1400
2800
1400
2800
2800
1400
850
1400
900
1400
1400
1400
1400
Max. Curr. (A)
230 400 690
1,65
0,84
1,65
0,84
4,42
1,44
6,01
8,61
1,94
1,08
2,69
1,51
2,69
3,48
4,74
6,31
0,95
0,48
0,95
0,48
2,55
0,83
3,48
4,98
1,12
0,62
1,56
0,87
1,56
2,01
2,75
3,65
-
R.R.P. €
Polyamide
344,60
338,50
345,40
334,50
429,70
390,10
450,90
518,90
374,20
334,90
402,60
478,80
419,80
452,10
480,80
534,00
R.R.P. €
Aluminium
406,60
399,50
407,60
394,70
507,10
460,30
532,10
612,40
441,50
395,20
475,00
565,00
495,40
533,50
567,30
630,10
65
AXIAL FANS
Code
Model
R.P.M.
max.
260600x06
260610x06
260620x06
260630x06
260640x06
260650x06
260660x06
260670x06
260680x06
260690x06
260700x06
260710x06
260720x06
260730x06
260740x06
260760x06
260770x06
260780x06
260800x06
260810x06
260820x06
260830x06
260840x06
260850x06
260860x06
260900x06
260910x06
260920x06
260930x06
260940x06
260950x06
260960x06
260100x06
260110x06
260120x06
260130x06
260140x06
260150x06
260160x06
270020x06
270030x06
270040x06
270050x06
270060x06
270070x06
270080x06
270090x06
HB 56 T6 0,25kW
HB 56 T6 0,37kW
HB 56 T6 0,55kW
HB 63 T4 0,75kW
HB 63 T4 1,1kW
HB 63 T4 1,5kW
HB 63 T4 2,2kW
HB 63 T4 3kW
HB 63 T6 0,37kW
HB 63 T6 0,55kW
HB 63 T6 0,75kW
HB 71 T4 1,1kW
HB 71 T4 1,5kW
HB 71 T4 2,2kW
HB 71 T4 3kW
HB 71 T6 0,55kW
HB 71 T6 0,75kW
HB 71 T6 1,1kW
HB 80 T4 2,2kW
HB 80 T4 3kW
HB 80 T4 4kW
HB 80 T6 0,75kW
HB 80 T6 1,1kW
HB 80 T6 1,5kW
HB 80 T6 2,2kW
HB 90 T4 3kW
HB 90 T4 4kW
HB 90 T4 5,5kW
HB 90 T4 7,5kW
HB 90 T6 1,5kW
HB 90 T6 2,2kW
HB 90 T6 3kW
HB 100 T4 5,5kW
HB 100 T4 7,5kW
HB 100 T4 11kW
HB 100 T4 15kW
HB 100 T6 2,2kW
HB 100 T6 3kW
HB 100 T6 4kW
HB 125 T4 11kW
HB 125 T4 15kW
HB 125 T4 18,5kW
HB 125 T4 22kW
HB 125 T6 3kW
HB 125 T6 4kW
HB 125 T6 7,5kW
HB 125 T6 11kW
900
900
900
1400
1400
1400
1430
1430
900
900
910
1400
1400
1430
1430
900
910
910
1430
1430
1440
910
910
940
940
1430
1440
1440
1440
940
940
960
1440
1440
1460
1460
940
960
960
1460
1460
1465
1470
960
960
965
970
Max. Curr. (A)
230 400 690
1,51
2,13
2,85
3,48
4,74
6,31
8,06
11,7
2,13
2,85
4
4,74
6,31
8,06
11,7
2,85
4
5,5
8,06
11,7
15,2
4
5,5
6,9
9,7
11,7
15,2
6,9
9,7
12,4
9,7
12,4
16,3
12,4
16,3
-
0,87
1,23
1,65
2,01
2,75
3,65
5
6,8
1,23
1,65
2,3
2,75
3,65
5
6,8
1,65
2,3
3,2
5
6,8
8,8
2,3
3,2
4
5,6
6,8
8,8
12
15
4
5,6
7,2
12
15
20,9
27,9
5,6
7,2
9,4
20,9
27,9
33
38,5
7,2
9,4
16,1
22,4
6,9
8,6
6,9
8,6
12,02
16,04
12,02
16,04
18,98
22,14
9,26
12,88
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,25
0,37
0,55
0,75
1,10
1,50
2,20
3,00
0,37
0,55
0,75
1,10
1,50
2,20
3,00
0,55
0,75
1,10
2,20
3,00
4,00
0,75
1,10
1,50
2,20
3,00
4,00
5,50
7,50
1,50
2,20
3,00
5,50
7,50
11,00
15,00
2,20
3,00
4,00
11,00
15,00
18,20
22,00
3,00
4,00
7,50
11,00
8680
9500
10170
14080
16500
18620
21010
23430
11440
12430
13860
20570
22000
23870
27060
15400
17480
19640
29700
34980
38700
23100
25840
28600
30620
37540
44320
49370
55040
30580
35390
39910
53080
61590
66450
71510
37740
45690
51450
82600
89000
97300
103700
50000
55800
73600
88600
62
62
63
72
73
74
75
76
63
64
65
78
79
80
81
66
67
68
83
84
85
70
73
74
75
87
88
90
91
78
79
80
92
92
93
94
82
83
84
91
91
92
92
82
83
85
87
19
20
22
26
30
32
41
43
24
26
33
33
35
45
47
34
36
38
53
55
60
44
46
52
57
61
66
82
93
58
63
87
90
101
124
139
71
95
103
245
265
330
430
330
335
380
395
R.R.P. €
Polyamide
R.R.P. €
Aluminium
442,90
504,90
553,40
491,30
537,10
638,80
731,30
759,90
469,90
568,90
491,30
531,50
646,10
770,40
804,40
605,60
629,10
667,90
904,40
934,50
1.051,40
793,70
845,40
869,90
956,60
1.040,50
1.047,20
1.215,50
1.321,90
923,40
1.004,60
1.168,20
1.395,50
1.544,70
2.160,00
2.270,70
1.339,30
1.500,40
1.732,00
3.242,40
3.378,40
3.725,80
3.927,20
2.618,20
2.844,60
3.242,40
3.398,50
522,70
595,80
653,00
579,70
633,80
753,80
863,00
896,60
554,40
671,30
579,70
627,10
762,40
909,00
949,20
714,60
742,30
788,10
1.067,20
1.102,70
1.240,60
936,60
997,50
1.026,40
1.128,80
1.227,80
1.235,70
1.434,20
1.559,80
1.089,60
1.185,40
1.378,40
1.646,70
1.822,80
2.548,80
2.679,50
1.580,30
1.770,50
2.043,70
3.826,10
3.986,60
4.396,50
4.634,10
3.089,40
3.356,70
3.826,10
4.010,20
R.R.P. €
Polyamide
R.R.P. €
Aluminium
THREE PHASE RANGE 2 SPEEDS
Model
R.P.M. max.
HB 56 T4/T8 0,85-0,20kW
HB 56 T4/T8 1,40-0,30kW
HB 56 T4/T8 1,80-0,40kW
HB 63 T4/T8 0,85-0,20kW
HB 63 T4/T8 1,40-0,30kW
HB 63 T4/T8 1,80-0,40kW
HB 63 T4/T8 2,20-0,60kW
HB 63 T4/T8 2,80-0,70kW
HB 71 T4/T8 1,40-0,30kW
HB 71 T4/T8 1,80-0,40kW
HB 71 T4/T8 2,20-0,60kW
HB 71 T4/T8 2,80-0,70kW
HB 80 T4/T8 2,20-0,60kW
HB 80 T4/T8 2,80-0,70kW
HB 80 T4/T8 4,00-1,00kW
HB 90 T4/T8 2,80-0,70kW
HB 90 T4/T8 4,00-1,00kW
HB 90 T4/T8 6,50-1,80kW
HB 100 T4/T8 6,50-1,80kW
HB 100 T4/T8 10,0-2,50kW
HB 100 T4/T8 16,0-4,50kW
1380/685
1380/685
1375/695
1380/685
1380/685
1375/695
1420/690
1420/695
1380/685
1375/695
1420/690
1420/695
1420/690
1420/695
1420/695
1420/695
1420/695
1460/725
1460/725
1450/730
1470/730
x=1 Polyamide (HB)
x=2 Aluminium (HBA)
66
Max. Curr. (A)
1500
750
2,33
2,33
4,44
2,33
2,33
4,44
5,34
6,3
2,33
4,44
5,34
6,3
5,34
6,3
6,3
6,3
6,3
13,9
13,9
20,2
29,9
0,88
0,88
1,43
0,88
0,88
1,43
2,18
2,42
0,88
1,43
2,18
2,42
2,18
2,42
2,42
2,42
2,42
5,62
5,62
6,6
11
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,85/0,2
1,4/0,3
1,8/0,4
0,85/0,2
1,4/0,3
1,8/0,4
2,2/0,6
2,8/0,7
1,4/0,3
1,8/0,4
2,2/0,6
2,8/0,7
2,2/0,6
2,8/0,7
4/1
2,8/0,7
4/1
6,5/1,8
6,5/1,8
10/2,5
16/4,5
12650/6325
13970/6985
15600/7800
14080/7040
16500/8250
18620/9310
21010/10505
23430/11715
20570/10285
22000/11000
23870/11935
27060/13530
29700/14850
34980/17490
38700/19350
37540/18770
44320/22160
49370/24685
53080/26540
66450/33225
71510/35755
73/57
74/58
76/60
71/59
72/60
74/62
75/63
76/64
78/64
79/65
79/66
80/67
81/67
82/68
83/69
85/70
86/71
88/73
89/71
90/72
91/72
22
26
28
26
30
32
41
42
33
35
45
46
53
54
59
60
65
87
96
117
138
580,30
608,00
664,00
773,90
793,10
836,70
933,40
991,40
769,00
802,80
894,70
967,30
1.112,40
1.199,30
1.281,70
1.305,70
1.354,20
1.842,60
2.123,20
2.490,70
3.231,60
780,60
817,90
893,30
1.040,90
1.066,90
1.125,60
1.255,60
1.333,70
1.034,50
1.079,90
1.203,60
1.301,20
1.496,40
1.613,50
1.724,10
1.756,70
1.821,70
2.478,80
3.350,60
4.347,30
5.624,90
LONG CASED AXIAL FANS
HM-HMA
Long cased variable pitch blades
MANUFACTURING FEATURES
• Reinforced fan casing manufactured in rolling
steel sheet.
• Motor-impeller modular assembly for complete
versatility.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors up to 4kW, and 400/690V 50Hz for higher
powers.
• HM: polyamide impeller with variable pitch angle
reinforced with fiberglass
• HMA: cast aluminium impeller with variable pitch
angle.
HM
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Air renewal in buildings and industries.
• Smoke extraction.
• Maximum working temperature: single phase
50ºC, three phase 60ºC.
UNDER REQUEST
• 100% reversible impeller. 5% additional cost.
• 60Hz fans and special voltages. 10% additional
cost in three phase models.
• Hot-dipped galvanised or stainless steel housing.
HMA
ACCESSORIES
REG
RFS
INT
PE
RP
AC
PO
BA-400
SIL-C
R.R.P. €
Polyamide
SINGLE PHASE RANGE
Code
Model
R.P.M.
max.
263070x03
263270x03
263100x03
263290x03
263140x03
263310x03
261410x03
261470x03
261480x03
261500x03
261510x03
261560x03
261600x03
261680x03
261760x03
HM 25 M2 0,12kW
HM 25 M4 0,08kW
HM 30 M2 0,37kW
HM 30 M4 0,12kW
HM 35 M2 0,37kW
HM 35 M4 0,12kW
HM 40 M4 0,25kW
HM 45 M4 0,37kW
HM 45 M6 0,12kW
HM 50 M4 0,55kW
HM 50 M6 0,25kW
HM 56 M4 0,55kW
HM 56 M6 0,25kW
HM 63 M6 0,37kW
HM 71 M6 0,55kW
2770
1370
2800
1400
2800
1400
1400
1400
900
1400
900
1400
900
900
900
Max. Curr. (A)
230
400
0,98
0,9
2,73
1,1
2,73
1,1
2,02
2,77
1,05
4,25
2,07
4,25
2,07
2,69
3,84
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,12
0,08
0,37
0,12
0,37
0,12
0,25
0,37
0,12
0,55
0,25
0,55
0,25
0,37
0,55
2950
1100
3100
1550
5200
2900
4700
7500
5200
10065
6000
11330
8680
11440
15400
70
55
71
56
77
60
64
68
55
70
58
73
61
63
68
7
7
8
8
12
11
18
15
14
20
19
21
19
24
29
-
356,70
361,50
375,80
370,10
376,90
364,10
421,30
515,20
492,00
539,60
520,20
563,80
590,80
757,60
933,90
R.R.P. €
Aluminium
406,70
412,10
428,40
422,00
429,70
415,10
480,30
587,30
560,90
615,10
593,00
642,70
673,50
863,70
1.064,70
THREE PHASE RANGE
Code
Model
R.P.M.
max.
263070x06
263270x06
263100x06
263290x06
263140x06
263310x06
261400x06
261410x06
261450x06
261460x06
261470x06
261480x06
261500x06
261510x06
HM 25 T2 0,12kW
HM 25 T4 0,08kW
HM 30 T2 0,37kW
HM 30 T4 0,12kW
HM 35 T2 0,37kW
HM 35 T4 0,12kW
HM 40 T2 1,1kW
HM 40 T4 0,25kW
HM 45 T2 1,5kW
HM 45 T2 2,2kW
HM 45 T4 0,37kW
HM 45 T6 0,12kW
HM 50 T4 0,55kW
HM 50 T6 0,25kW
2800
1400
2800
1400
2800
1400
2800
1400
2800
2800
1400
850
1400
900
Max. Curr. (A)
230 400 690
0,67
0,035
1,65
0,84
1,65
0,84
4,42
1,44
6,01
8,61
1,94
1,08
2,69
2,13
0,38
0,2
0,95
0,48
0,95
0,48
2,55
0,83
3,48
4,98
1,12
0,62
1,56
1,23
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,12
0,08
0,37
0,12
0,37
0,12
1,1
0,25
1,5
2,2
0,37
0,12
0,55
0,25
2950
1100
3100
1550
5200
2900
8500
4700
12100
13500
7500
5200
10065
6000
70
55
71
56
77
60
84
64
86
88
67
54
69
61
7
7
8
8
12
11
20
18
22
23
20
21
25
23
R.R.P. €
Polyamide
339,70
344,20
357,90
352,60
352,20
346,80
492,70
406,40
542,40
645,00
482,70
465,90
522,20
498,90
R.R.P. €
Aluminium
387,20
392,40
408,00
401,90
401,60
395,40
561,70
463,30
618,30
735,30
550,20
531,10
595,30
568,70
67
LONG CASED AXIAL FANS
Model
R.P.M.
max.
HM 56 T4 0,55kW
HM 56 T4 0,75kW
HM 56 T4 1,1kW
HM 56 T4 1,5kW
HM 56 T6 0,25kW
HM 56 T6 0,37kW
HM 56 T6 0,55kW
HM 63 T4 0,75kW
HM 63 T4 1,1kW
HM 63 T4 1,5kW
HM 63 T4 2,2kW
HM 63 T4 3kW
HM 63 T6 0,37kW
HM 63 T6 0,55kW
HM 63 T6 0,75kW
HM 71 T4 1,1kW
HM 71 T4 1,5kW
HM 71 T4 2,2kW
HM 71 T4 3kW
HM 71 T6 0,55kW
HM 71 T6 0,75kW
HM 71 T6 1,1kW
HM 80 T4 2,2kW
HM 80 T4 3kW
HM 80 T4 4kW
HM 80 T6 0,75kW
HM 80 T6 1,1kW
HM 80 T6 1,5kW
HM 80 T6 2,2kW
HM 90 T4 3kW
HM 90 T4 4kW
HM 90 T4 5,5kW
HM 90 T4 7,5kW
HM 90 T6 1,5kW
HM 90 T6 2,2kW
HM 90 T6 3kW
HM 100 T4 5,5kW
HM 100 T4 7,5kW
HM 100 T4 11kW
HM 100 T4 15kW
HM 100 T6 2,2kW
HM 100 T6 3kW
HM 100 T6 4kW
HM 125 T4 11kW
HM 125 T4 15kW
HM 125 T4 18,5kW
HM 125 T4 22kW
HM 125 T6 3kW
HM 125 T6 4kW
HM 125 T6 7,5kW
HM 125 T6 11kW
1400
1400
1400
1400
900
900
900
1400
1400
1400
1430
1430
900
900
910
1400
1400
1430
1430
900
910
910
1430
1430
1440
910
910
940
940
1430
1440
1440
1440
940
940
960
1440
1440
1460
1460
940
960
960
1460
1460
1465
1470
960
960
965
970
Code
261560x06
261570x06
261580x06
261590x06
261600x06
261610x06
261620x06
261630x06
261640x06
261650x06
261660x06
261670x06
261680x06
261690x06
261700x06
261710x06
261720x06
261730x06
261740x06
261760x06
261770x06
261780x06
261800x06
261810x06
261820x06
261830x06
261840x06
261850x06
261860x06
261900x06
261910x06
261920x06
261930x06
261940x06
261950x06
261960x06
261100x06
261110x06
261120x06
261130x06
261140x06
261150x06
261160x06
271020x06
271030x06
271040x06
271050x06
271060x06
271070x06
271080x06
271090x06
Max. Curr. (A)
230 400 690
2,69
3,48
4,74
6,31
1,51
2,13
2,85
3,48
4,74
6,31
8,06
11,7
2,13
2,85
4
4,74
6,31
8,06
11,7
2,85
4
5,5
8,06
11,7
15,2
4
5,5
6,9
9,7
11,7
15,2
6,9
9,7
12,4
9,7
12,4
16,3
12,4
16,3
0
0
1,56
2,01
2,75
3,65
0,87
1,23
1,65
2,01
2,75
3,65
5
6,8
1,23
1,65
2,3
2,75
3,65
5
6,8
1,65
2,3
3,2
5
6,8
8,8
2,3
3,2
4
5,6
6,8
8,8
12
15
4
5,6
7,2
12
15
20,9
27,9
5,6
7,2
9,4
20,9
27,9
33
38,5
7,2
9,4
16,1
22,4
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,55
0,75
1,1
1,5
0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
0,37
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
2,2
3
4
0,75
1,1
1,5
2,2
3
4
5,5
7,5
1,5
2,2
3
5,5
7,5
11
15
2,2
3
4
11
15
18,5
22
3
4
7,5
11
11330
12650
13970
15600
8680
9500
10170
14080
16500
18620
21010
23430
11440
12430
13860
20570
22000
23870
27060
15400
17480
19640
29700
34980
38700
23100
25840
28600
30620
37540
44320
49370
55040
30580
35390
39910
53080
61590
66450
71510
37740
45690
51450
82600
89000
97300
103700
50000
55800
73600
88600
73
74
75
76
62
62
63
72
73
74
75
76
63
64
65
78
79
80
81
66
67
68
83
84
85
70
73
74
75
87
88
90
91
78
79
80
92
92
93
94
82
83
84
91
91
92
92
77
78
80
82
28
29
33
35
23
27
29
37
41
43
54
56
35
37
44
45
48
63
65
41
48
50
68
70
75
59
61
67
72
87
92
107
118
84
89
112
120
131
155
170
101
125
133
235
255
320
420
320
325
370
385
6,9
8,6
6,9
8,6
12,02
16,04
12,02
16,04
18,98
22,14
9,26
12,88
R.R.P. €
Polyamide
537,00
556,90
604,10
659,70
562,60
627,40
678,10
625,30
672,10
727,90
886,90
947,30
696,00
701,90
809,60
786,90
842,20
927,70
985,70
896,50
946,20
978,10
1.128,20
1.165,80
1.287,30
1.080,60
1.116,50
1.205,30
1.217,90
1.222,50
1.300,00
1.466,40
1.588,20
1.556,80
1.567,20
1.733,50
1.748,20
1.990,10
2.578,80
2.848,20
1.619,70
1.854,10
2.030,40
3.988,60
4.199,20
4.414,80
4.816,10
3.487,70
3.672,30
3.977,40
4.113,80
R.R.P. €
Aluminium
612,10
634,90
688,70
752,10
641,40
715,30
773,00
712,90
766,20
829,80
1.011,10
1.079,90
793,40
800,20
922,90
897,10
960,10
1.057,50
1.123,70
1.022,00
1.078,70
1.115,00
1.286,10
1.329,00
1.467,50
1.231,90
1.272,80
1.374,00
1.388,40
1.393,60
1.482,00
1.671,80
1.810,60
1.774,80
1.786,60
1.976,10
1.992,90
2.268,70
2.939,80
3.247,00
1.846,50
2.113,60
2.314,60
4.547,00
4.787,10
5.032,90
5.490,40
3.976,00
4.186,40
4.534,20
4.689,70
THREE PHASE RANGE 2 SPEEDS
Model
HM 56 T4/T8 0,85-0,20kW
HM 56 T4/T8 1,40-0,30kW
HM 56 T4/T8 1,80-0,40kW
HM 63 T4/T8 0,85-0,20kW
HM 63 T4/T8 1,40-0,30kW
HM 63 T4/T8 1,80-0,40kW
HM 63 T4/T8 2,20-0,60kW
HM 63 T4/T8 2,80-0,70kW
HM 71 T4/T8 1,40-0,30kW
HM 71 T4/T8 1,80-0,40kW
HM 71 T4/T8 2,20-0,60kW
HM 71 T4/T8 2,80-0,70kW
HM 80 T4/T8 2,20-0,60kW
HM 80 T4/T8 2,80-0,70kW
HM 80 T4/T8 4,00-1,00kW
HM 90 T4/T8 2,80-0,70kW
HM 90 T4/T8 4,00-1,00kW
HM 90 T4/T8 6,50-1,80kW
HM 100 T4/T8 6,50-1,80kW
HM 100 T4/T8 10,0-2,50kW
x=1 Polyamide (HM)
x=2 Aluminium (HMA)
68
R.P.M. max.
Max. Curr.
(A) 400V
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1380/685
1395/705
1375/695
1380/685
1395/705
1375/695
1420/690
1420/695
1395/705
1375/695
1420/690
1420/695
1420/690
1420/695
1435/695
1420/695
1435/695
1460/725
1460/725
1450/730
2,33/0,88
3,63/1,21
4,44/1,43
2,33/0,88
3,63/1,21
4,44/1,43
5,34/2,18
6,3/2,42
3,63/1,21
4,44/1,43
5,34/2,18
6,3/2,42
5,34/2,18
6,3/2,42
9,2/3,7
6,3/2,42
9,2/3,7
13,9/5,62
13,9/5,62
20,2/6,6
0,85/0,2
1,4/0,3
1,8/0,4
0,85/0,2
1,4/0,3
1,8/0,4
2,2/0,6
2,8/0,7
1,4/0,3
1,8/0,4
2,2/0,6
2,8/0,7
2,2/0,6
2,8/0,7
4/1
2,8/0,7
4/1
6,5/1,8
6,5/1,8
10/2,5
12650/6325
13970/6985
15600/7800
14080/7040
16500/8250
18620/9310
21010/10505
23430/11715
20570/10285
22000/11000
23870/11935
27060/13530
29700/14850
34980/17490
38700/19350
37540/18770
44320/22160
49370/24685
53080/26540
66450/33225
73/57
74/58
75/59
71/56
72/57
74/59
75/60
76/61
77/62
79/63
80/64
81/65
82/66
83/67
84/68
86/70
87/71
88/72
90/74
91/75
29
32
35
37
40
43
54
55
44
48
63
64
68
69
73
86
90
116
153
169
R.R.P. €
Polyamide
728,40
754,50
819,60
931,50
957,60
1.022,70
1.126,90
1.211,80
993,10
1.058,20
1.162,60
1.247,40
1.353,90
1.438,60
1.536,50
1.502,10
1.599,80
2.186,70
3.230,70
4.091,40
R.R.P. €
Aluminium
830,30
860,20
934,40
1.061,80
1.091,70
1.165,90
1.284,70
1.381,50
1.132,10
1.206,40
1.325,40
1.422,00
1.543,40
1.640,10
1.751,70
1.712,40
1.823,80
2.492,80
3.683,00
4.091,40
LONG CASED AXIAL FANS
HI
Mancooler, variable pitch blades
MANUFACTURING FEATURES
• Reinforced fan casing manufactured in rolling
steel sheet.
• Motor-impeller modular assembly for complete
versatility.
• Polyamide impeller with variable pitch angle reinforced with fiberglass
• Epoxy powder finishing coat.
• Protection guards on both sides of the fan according to the ROHS 2002/95/EC Directive (Restriction
of the Use of Certain Hazardous Substances in Electrical and Electronic Equipments).
• Airstream direction adjustable.
• Fan support and protection guards supplied
apart.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors.
ACCESSORIES
RFS
INT
APPLICATIONS
Designed to be easily moved, they are suitable for:
• Ventilation of working places.
• Drying of pieces and surfaces.
• Maximum working temperature: single phase
50ºC, three phase 60ºC.
UNDER REQUEST
• B form impeller (air flow from impeller to motor),
100% reversible impeller. 5% additional cost.
• Aluminium impeller.
• 60Hz fans and special voltages. 10% additional
cost in three phase models.
• 2 speed motors.
• Flameproof and explosionproof fans with ATEX
certified motors.
• Hot-dipped galvanised or stainless steel housings.
PE
SINGLE PHASE RANGE
Code
HM 35+RP+PS
HM 35+RP+PS
HM 40+RP+PS
HM 45+RP+PS
HM 45+RP+PS
HM 56+RP+PS
HM 56+RP+PS
HM 63+RP+PS
HM 71+RP+PS
Model
R.P.M. max.
HI 35 M2 0,37kW
HI 35 M4 0,12kW
HI 40 M4 0,25kW
HI 45 M4 0,37kW
HI 45 M6 0,12kW
HI 56 M4 0,55kW
HI 56 M6 0,25kW
HI 63 M6 0,37kW
HI 71 M6 0,55kW
2800
1400
1400
1400
900
1400
900
900
900
Max. Curr. (A)
230
400
2,73
1,1
2,02
2,77
1,05
4,25
2,07
2,69
3,84
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,37
0,12
0,25
0,37
0,12
0,55
0,25
0,37
0,55
5200
2900
4700
7500
5200
11330
8680
11440
15400
77
60
64
68
55
73
61
63
68
16
15
22
21
20
30
28
35
41
R.R.P.
€
567,20
554,40
614,40
717,80
694,60
806,50
833,50
1.071,00
1.255,10
THREE PHASE RANGE
Code
HM 35+RP+PS
HM 35+RP+PS
HM 40+RP+PS
HM 45+RP+PS
HM 45+RP+PS
HM 56+RP+PS
HM 56+RP+PS
HM 56+RP+PS
HM 56+RP+PS
HM 56+RP+PS
HM 56+RP+PS
HM 56+RP+PS
HM 56+RP+PS
HM 63+RP+PS
HM 63+RP+PS
HM 63+RP+PS
HM 63+RP+PS
HM 63+RP+PS
HM 63+RP+PS
HM 63+RP+PS
HM 71+RP+PS
HM 71+RP+PS
HM 71+RP+PS
HM 71+RP+PS
HM 71+RP+PS
HM 71+RP+PS
HM 71+RP+PS
Model
HI 35 T2 0,37kW
HI 35 T4 0,12kW
HI 40 T4 0,25kW
HI 45 T4 0,37kW
HI 45 T6 0,25kW
HI 56 T4 0,55kW
HI 56 T4 0,75kW
HI 56 T4 1,1kW
HI 56 T4 1,5kW
HI 56 T6 0,25kW
HI 56 T6 0,37kW
HI 56 T6 0,55kW
HI 63 T4 0,75kW
HI 63 T4 1,1kW
HI 63 T4 1,5kW
HI 63 T4 2,2kW
HI 63 T4 3kW
HI 63 T6 0,37kW
HI 63 T6 0,55kW
HI 63 T6 0,75kW
HI 71 T4 1,1kW
HI 71 T4 1,5kW
HI 71 T4 2,2kW
HI 71 T4 3kW
HI 71 T6 0,55kW
HI 71 T6 0,75kW
HI 71 T6 1,1kW
R.P.M. max.
2800
1400
1400
1400
900
1400
1400
1400
1400
900
900
900
1400
1400
1400
1430
1430
900
900
910
1400
1400
1430
1430
900
910
910
Max. Curr. (A)
230
400
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,65
0,84
1,44
1,94
1,51
2,69
3,48
4,74
6,31
1,51
2,13
2,85
3,48
4,74
6,31
8,06
11,7
2,13
2,85
4
4,74
6,31
8,06
11,7
2,85
4
5,5
0,95
0,48
0,83
1,12
0,87
1,56
2,01
2,75
3,65
0,87
1,23
1,65
2,01
2,75
3,65
5
6,8
1,23
1,65
2,3
2,75
3,65
5
6,8
1,65
2,3
3,2
0,37
0,12
0,25
0,37
0,25
0,55
0,75
1,1
1,5
0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
0,37
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
5200
2900
4700
7500
5200
11330
12650
13970
15600
8680
9500
10170
14080
16500
18620
21010
23430
11440
12430
13860
20570
22000
23870
27060
15400
17480
19640
77
60
64
67
54
69
74
75
76
62
62
63
72
73
74
75
76
63
64
65
78
79
80
81
66
67
68
16
15
22
26
27
34
38
42
44
34
36
38
48
52
54
65
67
46
48
55
57
60
75
77
53
60
62
R.R.P.
€
542,50
537,10
599,50
685,30
668,50
779,70
799,60
846,80
902,40
805,30
870,10
920,80
868,00
985,50
1.041,30
1.200,30
1.260,70
1.009,40
1.015,30
1.123,00
1.108,10
1.163,40
1.248,90
1.306,90
1.217,70
1.267,40
1.299,30
69
LONG CASED AXIAL FANS
HH
External motor, variable pitch blades
MANUFACTURING FEATURES
• Transmission ball bearings set inside a sealed box
manufactured in steel or cast aluminium. Ball bearings permanently greased.
• Cast aluminium impeller with variable pitch angle.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors up to 4kW, and 400/690V 50Hz for higher
powers.
• Inspection door for motor access and transmission set located on the lower part of the housing.
• Maximum working temperature: carried air
110ºC; environment: 60ºC.
UNDER REQUEST
• B form impeller (air flow from impeller to motor),
100% reversible impeller. 5% additional cost.
• Polyamide impeller.
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof and explosionproof fans with ATEX
certified motors.
• Hot-dipped galvanised or stainless steel housing.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Air renewal in buildings and industries.
• Hot air extraction up to 110ºC.
ACCESSORIES
RFS
INT
PE
RP
AC
PO
BA-400
SIL-C
THREE PHASE RANGE
70
Code
Model
R.P.M. max.
264100106
264310106
264340106
264340120
264380106
264380120
264390106
264400106
264420106
264420120
264440106
264450106
HH 35 T2 0,55kW
HH 35 T4 0,12kW
HH 45 T4 0,25kW
HH 45 T4 0,37kW
HH 56 T4 0,55kW
HH 56 T4 0,75kW
HH 56 T4 1,1kW
HH 63 T4 1,1kW
HH 71 T4 1,1kW
HH 71 T4 1,5kW
HH 90 T4 3kW
HH 90 T4 5,5kW
2800
1400
1400
1400
1400
1400
1400
1400
1400
1400
1430
1440
Max. Curr. (A)
230 400 690
2,33
0,84
1,44
1,94
2,69
3,48
4,74
4,74
4,74
6,31
11,7
-
1,35
0,48
0,83
1,12
1,56
2,01
2,75
2,75
2,75
3,65
6,8
12
6,9
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,55
0,12
0,25
0,37
0,55
0,75
1,1
1,1
1,1
1,5
3
5,5
5040
2810
6310
7280
10990
12270
13550
16010
19950
21340
36410
47890
76
59
69
69
72
73
74
74
78
79
88
91
22
20
32
36
36
36
39
59
74
77
113
132
R.R.P.
€
752,90
724,60
766,60
804,60
857,90
883,50
1.011,20
1.041,40
1.110,00
1.168,00
2.408,40
2.601,90
LONG CASED AXIAL FANS
HHP
External motor, split casing for maintenance, variable pitch blades
MANUFACTURING FEATURES
• Transmission ball bearings set inside a sealed
box manufactured in steel or cast aluminium. Ball
bearings permanently greased.
• Cast aluminium impeller with variable pitch
angle.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor
with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in
single phase motors and 230/400V 50Hz in three
phase motors up to 4kW, and 400/690V 50Hz for
higher powers.
• Fan opening option (180º) for easier maintenance and no need of disassembly from the installation.
ACCESSORIES
RFS
INT
PE
RP
AC
PO
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Air renewal in buildings and industries.
• Hot air extraction up to 110ºC.
• Maximum working temperature: carried air
110ºC; environment: 60ºC.
UNDER REQUEST
• B form impeller (air flow from impeller to motor),
100% reversible impeller. 5% additional cost.
• Polyamide impeller.
• 60Hz fans and special voltages. 10% additional
cost in three phase models.
• 2 speed motors.
• Flameproof and explosionproof fans with ATEX
certified motors.
• Hot-dipped galvanised or stainless steel housing.
BA-400
SIL-C
THREE PHASE RANGE
Code
Model
R.P.M.
max.
264340160
264340161
264380160
264380161
264390160
264400160
264410160
264420160
264420161
264440160
264450160
264450161
HHP 45 T4 0,25kW
HHP 45 T4 0,37kW
HHP 56 T4 0,55kW
HHP 56 T4 0,75kW
HHP 56 T4 1,1kW
HHP 63 T4 1,1kW
HHP 63 T4 1,5kW
HHP 71 T4 1,1kW
HHP 71 T4 1,5kW
HHP 90 T4 3kW
HHP 90 T4 4kW
HHP 90 T4 5,5kW
1400
1400
1400
1400
1400
1400
1400
1400
1400
1430
1440
1440
Max. Curr. (A)
230 400 690
1,44
1,94
2,69
3,48
4,74
4,74
6,31
4,74
6,31
11,7
15,2
-
0,83
1,12
1,56
2,01
2,75
2,75
3,65
2,75
3,65
6,8
8,8
12
6,9
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,25
0,37
0,55
0,75
1,1
1,1
1,5
1,1
1,5
3
4
5,5
6310
7280
10990
12270
13550
16010
18060
19950
21340
36410
42990
47890
69
69
72
73
74
74
78
78
79
88
89
91
32
36
36
36
39
59
63
74
77
113
118
132
R.R.P.
€
988,10
1.005,20
1.011,60
1.035,50
1.057,60
1.343,00
1.391,60
1.443,90
1.491,40
2.909,00
3.244,40
3.273,40
71
CENTRIFUGAL LOW PRESSURE FANS
BD-BD CUBIC
Double inlet, IP55 closed motor
MANUFACTURING FEATURES
• Galvanised steel sheet housing.
• Polyamide impeller reinforced with fiberglass in
models 7/7, 9/9, 10/10 and 12/12. Galvanised
steel sheet impeller in the rest of models.
• Double inlet forward curved impeller in all models
except 25/13, with single inlet.
• Supplied with mounting feet (included in price)
except cubic models, supported and reinforced by
lateral plates.
• BD CUBIC model supplied with fan support reinforced with squared wings for a major rigidity and
solidity.
• Motor fixing with an exclusive system designed by
Casals through flexible arms and silent blocks to
avoid vibration. Flexible arms in compliance with
the ROHS 2002/95/EC Directive (Restriction of the
Use of Certain Hazardous Substances in Electrical
and Electronic Equipments).
• Closed motors specially designed by Casals: extruded aluminium motor housing, wiring box fit in
the motor with IP-65 protection. Motor with IP-55
protection and Class F insulation. Manufactured
with standard voltages: 230V 50 Hz in single phase
motors and 230/400V 50 Hz in three phase motors.
• Motors with controllable voltage speed except
three phase motors only controlled by frequency.
BD
APPLICATIONS
Designed for assembly in equipment:
• Ventilation boxes and air handling units.
• Centrifugal heaters.
• Industrial and professional kitchen hoods.
• Maximum working temperature: 50ºC.
UNDER REQUEST
• 60Hz fans.
• Fan assembly in the requested position.
• Fan assembly with the requested power.
BD CUBIC
ACCESSORIES
72
REG
RFS
INT
PE
RA
RM
RI
MBI
CENTRIFUGAL LOW PRESSURE FANS
SINGLE PHASE RANGE BD
Code
Model
Equivalence
cm
R.P.M.
max.
251100141
251160160
251350103
251260160
251220163
251220166
251280162
251280167
251330161
251320160
251370162
251370125
251600160
251600162
251520163
251520161
251520165
BD 7/7 M4 0,15kW
BD 7/7 M6 0,08kW
BD 9/5 M6 0,08kW
BD 9/7 M6 0,15kW
BD 9/9 M4 0,37kW
BD 9/9 M4 0,55kW
BD 9/9 M6 0,15kW
BD 9/9 M6 0,25kW
BD 10/8 M6 0,25kW
BD 10/10 M4 0,55kW
BD 10/10 M6 0,25kW
BD 10/10 M6 0,37kW
BD 12/9 M6 0,55kW
BD 12/9 M6 0,75kW
BD 12/12 M6 0,55kW
BD 12/12 M6 0,75kW
BD 12/12 M6 1,1kW
19/19
19/19
25/13
25/20
25/25
25/25
25/25
25/25
28/21
28/28
28/28
28/28
33/25
33/25
33/33
33/33
33/33
1300
860
860
850
1350
1350
850
900
900
1350
900
890
860
840
860
840
860
Max. Curr. (A) Rated Power
kW
230
400
1,85
1,03
1,03
1,69
2,83
4,86
1,69
2,33
2,33
4,86
2,33
3,33
4,93
6,86
4,93
6,86
9,26
-
0,15
0,08
0,08
0,15
0,37
0,55
0,15
0,25
0,25
0,55
0,25
0,37
0,55
0,75
0,55
0,75
1,1
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1550
1400
980
2000
3400
3500
2600
2700
3400
4100
3400
3900
4800
6000
5700
6800
7900
60
52
55
57
64
66
60
62
64
66
64
64
67
67
67
67
69
7,5
7,3
11
12
14,8
15
14,5
14,7
14,9
16,5
15,5
16
20
21
25
25,5
28
Air flow
m3/h
Sound
dB (A)
Weight
Kg
6900
7900
65
68
22
26
Air flow
m3/h
Sound
dB (A)
Weight
Kg
12000
78
57
R.R.P.
€
221,20
219,00
232,60
264,10
288,30
302,60
269,30
285,80
297,50
319,20
301,20
321,40
446,10
491,90
464,10
485,30
603,10
THREE PHASE RANGE BD
Code
Model
Equivalence
cm
R.P.M.
max.
251600161
251520160
BD 12/9 T6 1,1kW
BD 12/12 T6 1,1kW
33/25
33/33
960
960
Max. Curr. (A) Rated Power
kW
230
400
6,54
6,54
3,78
3,78
1,1
1,1
R.R.P.
€
463,30
465,20
THREE PHASE RANGE BD CÚBIC
Code
Model
Equivalence
cm
R.P.M.
max.
252370106
BD 15/15 T6 2,2kW
39/39
900
Max. Curr. (A) Rated Power
kW
230
400
10,92
6,31
2,2
R.R.P.
€
868,00
73
CENTRIFUGAL LOW PRESSURE FANS
BD 3V
Double inlet, IP55 closed 3 speed motor
MANUFACTURING FEATURES
• Galvanised steel sheet housing.
• Polyamide curved impeller reinforced with fiberglass in all models.
• Supplied with mounting feet (included in price).
• Motor fixing with an exclusive system designed by
Casals through flexible arms and silent blocks to
avoid vibration. Flexible arms in compliance with
the ROHS 2002/95/EC Directive (Restriction of the
Use of Certain Hazardous Substances in Electrical
and Electronic Equipments).
• Closed motors specially designed by Casals: extruded aluminium motor housing, wiring box fit in
the motor with IP-65 protection. Motor with IP-55
protection and Class F insulation. Manufactured
with standard voltages: 230V 50 Hz in three phase
motors.
• Thermal protector included.
ACCESSORIES
REG
RFS
INT
INT 3V
PE
APPLICATIONS
Designed for assembly in equipment:
• Ventilation boxes and air handling units.
• Centrifugal heaters.
• Industrial and professional kitchen hoods.
• Maximum working temperature: 50ºC.
UNDER REQUEST
• 60Hz fans.
• Fan assembly in the requested position.
RA
RM
RI
MBI
SINGLE PHASE RANGE
Model
BD 7/7 M4 0,15kW 3V
BD 7/7 M6 0,08kW 3V
BD 9/9 M4 0,37kW 3V
BD 9/9 M6 0,15kW 3V
BD 9/9 M6 0,25kW 3V
BD 10/10 M4 0,55kW 3V
BD 10/10 M6 0,25kW 3V
BD 10/10 M6 0,37kW 3V
BD 12/12 M6 0,55kW 3V
BD 12/12 M6 0,75kW 3V
74
R.P.M. max.
Max. C. (A)
Equivalence
Rated
cm
Speed 1 Speed 2 Speed 3 230 400 Power kW
19/19
19/19
25/25
25/25
25/25
28/28
28/28
28/28
33/33
33/33
1360
790
1400
800
900
1400
870
850
900
860
1266
736
1260
708
797
1216
744
738
864
812
1126
681
1167
646
697
1032
653
526
756
749
1,4
1
4,7
2,1
2,12
5,3
2,5
2,5
5,1
6
-
0,15
0,08
0,37
0,15
0,25
0,55
0,25
0,37
0,55
0,75
Air flow m3/h
Sp 1 Sp 2
Sp 3
1450
1450
3000
2600
2710
3800
3600
3800
5000
5900
1350
1350
2700
2300
2400
3300
3080
3300
4800
5575
1200
1250
2500
2100
2100
2800
2700
2350
4200
5150
Sound
dB (A)
Weight
Kg
60
52
64
57
57
66
64
57
67
67
9
9
18
18
18
25
24
25
27
27
R.R.P.
€
267,40
265,30
354,10
307,60
323,50
368,60
340,70
368,60
515,00
540,40
CENTRIFUGAL LOW PRESSURE FANS
BDE
Double inlet, external rotor motor
MANUFACTURING FEATURES
• Fully made of galvanised steel sheet.
• Double inlet forward curved impeller in all models.
• Supplied with mounting feet (included in price).
• External rotor motor and impeller assembled as a
set, supported by fixing arms.
• External rotor motor with IP-44 protection and
Class F insulation according to the DIN 40.050 h1
Standard. Thermal contact protection, ball bearings
permanently greased and 100% controllable voltage. Manufactured with standard voltages: 230V
50Hz in single phase motors and 230/400V in
three phase motors.
ACCESSORIES
REG
RFS
INT
PE
RA
APPLICATIONS
Designed for assembly in equipment:
• Ventilation boxes and air handling units.
• Centrifugal heaters.
• Industrial and professional kitchen hoods.
• Maximum working temperature: 50ºC.
RI
MBI
SINGLE PHASE RANGE
Code
Model
Equivalence
cm
R.P.M. max.
251100140
251160140
251220140
251280140
251320140
251370140
251520140
BDE 7/7 M4 0,15kW
BDE 7/7 M6 0,08kW
BDE 9/9 M4 0,37kW
BDE 9/9 M6 0,25kW
BDE 10/10 M4 0,55kW
BDE 10/10 M6 0,37kW
BDE 12/12 M6 0,75kW
19/19
19/19
25/25
25/25
28/28
28/28
33/33
1300
860
1350
900
1350
890
840
Max. Curr. (A) Rated Power
kW
230
400
1,85
1,03
2,83
2,33
4,86
3,33
6,86
-
0,15
0,08
0,37
0,25
0,55
0,37
0,75
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1500
1450
3450
2350
3800
4000
5500
55
47
59
52
61
59
60
8
8
16
16
20
20
29
Air flow
m3/h
Sound
dB (A)
Weight
Kg
7500
63
29
R.R.P.
€
531,00
525,30
673,10
627,90
794,60
792,50
1.042,10
THREE PHASE RANGE
Code
Model
Equivalence
cm
R.P.M. max.
251520143
BDE 12/12 T6 1,1kW
12/12
960
Max. Curr. (A) Rated Power
kW
230
400
6,54
3,78
1,1
R.R.P.
€
1.006,10
75
CENTRIFUGAL LOW PRESSURE FANS
BV-BVC-BVCR
Double inlet, free shaft with no motor
MANUFACTURING FEATURES
• Galvanised steel sheet housing.
• Double inlet forward curved impeller in all models
• Transmission shaft with anticorrosion treatment.
• Supplied with free shaft.
• Transmission shaft standing out on both sides of
the fan to allow motor, pulleys and belts assembly.
• BV fan supplied with supports (included in price)
except for sizes 39/39 and 47/47.
• BV/BVC: Impellers made of polyamide reinforced
with fiberglass for sizes 7/7, 9/9, 10/10 and 12/12;
in other models made of galvanised steel sheet. Ball
bearings permanently greased on rubber rings.
• BVC/BVCR: Reinforced cubic assembly with lateral panels and a bearings base plate.
• BVCR: Fan with reinforced structure and bridge
bearings supported on the rigid structure.
BV
APPLICATIONS
Designed for assembly in equipment:
• Ventilation boxes and air handling units.
• Centrifugal heaters.
• Industrial and professional kitchen hoods.
• Maximum working temperature: 60ºC.
UNDER REQUEST
• Fully equipped fan with motor, pulleys and belts.
BVC
BVCR
ACCESSORIES BV
ACCESSORIES BV
76
TM
S
RA
MBI
TM
BS
RA
MBI
Model
Equivalence
cm
R.P.M.
max.
Max. Power
CV
Rated
Power kW
Air flow
m3/h
Weight
Kg
BV 7/7
BV 9/7
BV/BVC 9/9
BV 10/8
BV/BVC 10/10
BV 12/9
BV/BVC 12/12
BV/BVC/BVCR 15/15
BV/BVC/BVCR 18/18
BVCR 20/20
BVCR 22/22
BVCR 25/25
BVCR 30/28
19/19
25/20
25/25
28/21
28/28
33/25
33/33
39/39
47/47
51/51
56/56
63/63
76/71
2000
1500
1500
1300
1300
1200
1200
1100
900
800
700
550
450
1,5
2
2
2
3
4
4
5,5
7,5
10
10
15
20
1,1
1,5
1,5
1,5
2
3
3
4
5,5
7,5
7,5
11
15
3400
5500
6000
6700
7500
10000
11000
16000
25000
29000
32000
42000
62000
6
8
9
11
12
17
20
34
46
84
94
113
145
R.R.P. €
BV
118,30
135,20
137,70
144,30
147,90
175,90
184,20
323,00
376,70
-
R.R.P. €
BVC
209,70
227,40
263,90
417,70
487,90
-
R.R.P. €
BVCR
540,70
680,20
1.041,40
1.139,30
1.112,80
1.639,70
CENTRIFUGAL LOW PRESSURE FANS
BC
Single inlet, standard B5 motor
MANUFACTURING FEATURES
• Galvanised steel sheet housing and epoxy powder
finishing coat.
• Single inlet forward curved impeller.
• Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors,
230/400V 50Hz for three phase.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean air transport.
• Maximum air working temperature: 130ºC in
continuous.
ACCESSORIES
RFS
INT
PE
RA
AC
EI
BA-400
SIL-C
SIL-R
SINGLE PHASE RANGE
Code
Model
R.P.M. max.
251200103
251360103
251670103
BC 25/10 M4 0,55kW
BC 28/11 M4 1,1kW
BC 35/18 M4 1,5kW
1400
1400
1400
Max. Curr. (A)
230
400
4,25
7,45
9,83
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,55
1,1
1,5
2200
3400
5200
64
68
78
17,5
29,5
34
R.R.P.
€
471,60
568,20
704,60
THREE PHASE RANGE
Code
251200106
251360106
251670106
251650106
Model
BC 25/10 T4 0,55kW
BC 28/11 T4 1,1kW
BC 35/18 T4 1,5kW
BC 35/18 T6 0,75kW
R.P.M. max.
1400
1400
1400
910
Max. Curr. (A)
230
400
2,69
4,74
6,31
4
1,56
2,75
3,65
2,3
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,55
1,1
1,5
0,75
2200
3400
5200
4000
64
68
75
61
18
29,5
34
32
R.R.P.
€
421,20
555,30
679,90
655,80
77
CENTRIFUGAL LOW PRESSURE FANS
BST
Single inlet, free shaft with no motor
MANUFACTURING FEATURES
• Fully made of galvanised steel sheet.
• Simple inlet forward curved impeller in all models.
• Transmission shaft with anticorrosion
treatment.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Vertical discharge, circular pipes, blind cover.
• Check prices with motor or transmission.
• Totally assembled fan with motor, belts and pulleys.
APPLICATIONS
Designed for assembly in equipment:
• Ventilation boxes and air handling units.
• Centrifugal heaters.
• Industrial and professional kitchen hoods.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
ACCESSORIES
Model
BST 9/4
BST 10/5
BST 12/6
BST 15/7
BST 18/9
BST 20/10
BST 22/11
BST 25/13
BST 30/14
78
RFS
INT
PE
R.P.M. max.
Air flow
m3/h
Weight
Kg
1600
1500
1400
1050
1000
900
850
600
500
3200
4900
6500
9700
10800
20000
24000
29500
34000
9,6
11
17,5
22,5
33
71
80
93
125
R.R.P.
€
257,30
269,30
314,60
358,90
434,40
926,10
1.000,00
1.167,10
1.401,10
CENTRIFUGAL MEDIUM PRESSURE FANS
BCI
Inflatable slides and castles
MANUFACTURING FEATURES
• Fully made of galvanised steel sheet.
• Single inlet forward curved impeller in all models.
• Portable box with anti-return valve.
• Circular outlet for direct connection to duct or inflatable input.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz.
• Default assembly position is LG270.
ACCESSORIES
RFS
INT
PE
APPLICATIONS
• Inflatable slides and castles.
• Industrial applications, air extraction or injection.
• Maximum working temperature: carried air
130ºC; environment: single phase 50ºC, three
phase 60ºC.
BA-400
SINGLE PHASE RANGE
Code
Model
R.P.M. max.
253250103
253260103
253260120
253320103
BCI 20/8 M2 1,1kW
BCI 22/9 M2 1,1kW
BCI 22/9 M2 1,5kW
BCI 25/10 M2 1,5kW
2800
2800
2800
2800
Max. Curr. (A)
230
400
7,02
7,02
9,44
9,44
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,1
1,1
1,5
1,5
1300
500
1100
700
60
70
70
75
27
38
39
45
R.R.P.
€
777,20
785,10
823,60
834,70
79
CENTRIFUGAL MEDIUM PRESSURE FANS
MA
Radial aluminium impeller, steel sheet casing
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Cast aluminium impeller.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
APPLICATIONS
Designed for inline installation, they are suitable for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean and slightly dusty air transport.
ACCESSORIES
RFS
INT
PE
RA
AC
BA-400
SIL-C
SIL-R
SINGLE PHASE RANGE
Code
Model
R.P.M. max.
253180162
253220162
253270162
MA 18 M2 0,1kW
MA 24 M2 0,1kW
MA 25 M2 0,18kW
2760
2760
2800
Max. Curr. (A)
230
400
0,81
0,81
1,48
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,09
0,09
0,18
295
350
560
60
65
68
6
7
11
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,09
0,09
0,18
295
350
560
60
65
68
6
7
11
R.R.P.
€
269,00
304,90
359,40
THREE PHASE RANGE
80
Code
Model
R.P.M. max.
253180161
253220161
253270161
MA 18 T2 0,1kW
MA 24 T2 0,1kW
MA 25 T2 0,18kW
2800
2800
2800
Max. Curr. (A)
230
400
0,57
0,57
0,91
0,33
0,33
0,53
R.R.P.
€
256,30
290,40
342,40
CENTRIFUGAL MEDIUM PRESSURE FANS
MA
Forward impeller, aluminium cast casing
MANUFACTURING FEATURES
• Cast aluminium housing.
• Cast aluminium forward blades casing.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
ACCESSORIES
RFS
INT
PE
RA
AC
• Cooling of machines and parts.
• Clean and slightly dusty air transport.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof and explosionproof fans with
• ATEX certified motors. See ATEX section.
BA-400
SIL-C
SIL-R
SINGLE PHASE RANGE
Code
Model
R.P.M. max.
253300104
MA 26 M2 0,37kW
2800
Max. Curr. (A)
230
400
2,73
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,37
870
72
13
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,37
0,55
1,1
1,5
870
1100
2150
2550
71
80
80
83
13
14
20
27
R.R.P.
€
400,80
THREE PHASE RANGE
Code
Model
R.P.M. max.
253300106
253330106
253390106
253440106
MA 26 T2 0,37kW
MA 27 T2 0,55kW
MA 28 T2 1,1kW
MA 31 T2 1,5kW
2800
2800
2800
2800
Max. Curr. (A)
230 400 690
1,65
2,33
4,42
6,01
0,95
1,35
2,55
3,48
-
R.R.P.
€
380,70
471,10
604,20
802,50
81
CENTRIFUGAL MEDIUM PRESSURE FANS
MDE
Forward impeller, external rotor motor
MANUFACTURING FEATURES
• Welded rolled steel sheet housing .
• Galvanised steel sheet single inlet forward curved
impeller.
• Inlet protection guard included.
• Epoxy powder finishing coat.
• Asynchronous external rotor with IP-44 protection
and Class B insulation according to the DIN 40.050
h1 Standard; greased for life ball bearings. Standard voltages: 230V 50Hz.
ACCESSORIES
REG
INT
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean air transport.
• Maximum working temperature: 50ºC.
PE
SINGLE PHASE RANGE
Code
300712100
300712200
300712300
300712400
82
Model
MDE 120
MDE 130
MDE 140
MDE 150
R.P.M. max.
2930
2890
2890
2900
Max. Curr. (A)
230
400
0,4
0,5
0,97
1
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,065
0,12
0,18
0,24
189
396
504
600
60
61
63
64
2,4
3
3,3
3,4
R.R.P.
€
105,00
116,50
133,10
140,90
CENTRIFUGAL MEDIUM PRESSURE FANS
MB
Forward impeller
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Completely joined or welded housing.
• Galvanised steel sheet and single inlet forward
curved impeller.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors up to 4kW, and 400/690V 50Hz for higher
powers.
MB 12/5 - 20/8
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof and explosionproof fans with ATEX
certified motors. See ATEX section.
• Fans for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
• Fans provided with cooling disk for high temperatures.
-MB 12/5-20/8: 105€ additional cost.
-MB 22/9-28/11: 115€ additional cost.
-MB 31/12-45/18: 125€ additional cost.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean air transport.
• Maximum working temperature: carried air
130ºC; environment: single phase 50ºC, three
phase 60ºC.
MB 22/9 - 28/11
ACCESSORIES
REG
RFS
AC
MB 31/12 - 45/18
EI
INT
PE
BA-400
SIL-C
RA
SIL-R
SINGLE PHASE RANGE
Code
253060103
253080103
253100103
253110103
253160103
253170103
253340103
253240103
253190103
253230103
Model
R.P.M. max.
MB 12/5 M2 0,1kW
MB 12/5 M4 0,08kW
MB 14/5 M2 0,25kW
MB 16/6 M2 0,37kW
MB 16/6 M4 0,18kW
MB 18/7 M2 0,75kW
MB 18/7 M4 0,25kW
MB 20/6 M2 0,37kW
MB 20/8 M2 1,1kW
MB 20/8 M4 0,37kW
2760
1360
2800
2800
1400
2800
1400
2800
2800
1400
Max. Curr. (A)
230
400
0,81
0,59
1,96
2,73
1,62
5,15
2,02
2,73
7,02
2,77
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,09
0,08
0,25
0,37
0,18
0,75
0,25
0,37
1,1
0,37
510
320
1050
1400
1100
1900
1200
880
2100
2200
62
50
59
70
57
68
63
68
68
60
5
5
7
9,5
9,5
15
10
14
19
15
-
R.R.P.
€
159,80
172,70
188,20
192,90
198,50
350,10
343,40
388,10
404,10
365,40
THREE PHASE RANGE
Code
253060106
253080106
253100106
253110106
253160106
253170106
253340106
Model
MB 12/5 T2 0,1kW
MB 12/5 T4 0,08kW
MB 14/5 T2 0,25kW
MB 16/6 T2 0,37kW
MB 16/6 T4 0,18kW
MB 18/7 T2 0,75kW
MB 18/7 T4 0,25kW
R.P.M. max.
2800
1400
2800
2800
1400
2800
1400
Max. Curr. (A)
230 400
690
0,57
0,49
1,17
1,65
1,12
3,03
1,44
0,33
0,28
1,68
0,95
0,65
1,75
0,83
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,09
0,08
0,25
0,37
0,18
0,75
0,25
510
320
1050
1400
1100
1900
1200
62
50
59
70
57
68
63
5
5
7
9,5
9,5
15
10
R.R.P.
€
140,10
157,00
171,10
175,30
180,40
327,80
312,20
83
CENTRIFUGAL MEDIUM PRESSURE FANS
Code
Model
R.P.M. max.
253240106
253190106
253230106
253210120
253200106
253200120
253280106
253290106
253310106
253360106
253370106
253380106
253450120
253450106
253480106
253480120
253510121
253510106
253510120
253530106
253530120
253530121
253560106
MB 20/6 T2 0,37kW
MB 20/8 T2 1,1kW
MB 20/8 T4 0,37kW
MB 22/9 T2 1,1kW
MB 22/9 T2 2,2kW
MB 22/9 T4 0,55kW
MB 25/10 T2 2,2kW
MB 25/10 T2 3kW
MB 25/10 T4 1,1kW
MB 28/11 T2 4kW
MB 28/11 T4 2,2kW
MB 28/11 T6 0,75kW
MB 31/12 T4 3kW
MB 31/12 T4 4kW
MB 35/14 T4 3kW
MB 35/14 T4 5,5kW
MB 40/16 T4 5,5kW
MB 40/16 T4 7,5kW
MB 40/16 T6 2,2kW
MB 45/18 T4 5,5kW
MB 45/18 T4 7,5kW
MB 45/18 T4 11kW
MB 45/18 T6 2,2kW
2800
2800
1400
2800
2800
1400
2800
2870
1400
2890
1430
910
1430
1440
1430
1440
1440
1440
940
1440
1440
1460
940
MZ
Max. Curr. (A)
230 400
690
1,65
4,42
1,94
4,42
8,61
2,69
8,61
11,1
4,74
14,2
8,06
4
11,7
15,2
11,7
9,7
9,7
0,95
2,55
1,12
2,55
4,98
1,56
4,98
6,4
2,75
8,2
5
2,3
6,8
8,8
6,8
12
12
15
5,6
12
15
20,9
5,6
6,9
6,9
8,6
6,9
8,6
12,02
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,37
1,1
0,37
1,1
2,2
0,55
2,2
3
1,1
4
2,2
0,75
3
4
3
5,5
5,5
7,5
2,2
5,5
7,5
11
2,2
880
2100
2200
1800
3000
2700
2600
3200
3500
4000
5000
3600
5700
6800
6000
9000
9000
11000
7000
8000
11000
18000
9000
68
68
60
70
74
60
77
78
64
81
68
58
72
73
78
79
78
79
71
80
82
86
76
14
19
15
24
30
22
32
38
33
46
44
37
57
59
63
76
101
110
94
116
119
190
112
R.R.P.
€
352,90
378,50
332,20
519,50
544,70
469,20
588,70
642,40
633,10
802,30
721,70
625,90
1.079,70
1.146,70
1.176,10
1.316,80
1.483,70
1.542,00
1.367,70
1.745,90
1.816,10
2.113,00
1.470,30
Forward impeller, free shaft without motor
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Completely joined or welded housing.
• Galvanised steel sheet single inlet forward curved
impeller.
• Standard fan supplied with free shaft, i.e. without
motor, pulleys or belts.
• Epoxy powder finishing coat.
UNDER REQUEST
• Fully equipped fans, including motor, pulleys,
belts, belt and shaft guard. Mounted on a base
plate or an upper plate.
• Flameproof and explosionproof fans with ATEX
certified motors.
• Fans for air working temperatures up to 350ºC.
• Hot-dipped galvanised or stainless steel fans.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean air transport.
• Maximum working temperature: carried air
200ºC; environment: 60ºC.
UNDER REQUEST
ACCESSORIES
Code
254120160
254180160
254210160
254230160
254330160
254370160
254420160
254540160
84
Model
MZ 22/9
MZ 25/10
MZ 28/11
MZ 31/12
MZ 35/14
MZ 40/16
MZ 45/18
MZ 63/25
REG
RFS
INT
PE
RA
R.P.M. max.
Rated Power
máx. kW
Air flow
m3/h
3400
3000
2850
2425
1900
1650
1510
960
3
4
5,5
7,5
7,5
11
11
22
4000
5200
6900
8500
11000
14000
17000
32000
AC
EI
P. máx.
Ps (mm H2O)
220
220
230
250
200
190
200
180
BA-400
Weight
Kg
18
24
27
40
56
71
85
115
SIL-C
SIL-R
R.R.P.
€
596,80
679,30
731,70
1.130,50
1.447,80
1.288,00
1.582,60
3.390,00
CENTRIFUGAL MEDIUM PRESSURE FANS
MBCA
Forward impeller
MANUFACTURING FEATURES
• Completely joined or welded rolling steel sheet
housing.
• Single inlet forward curved impeller in galvanised
sheet.
• Epoxy powder finishing coat.
• Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard
voltages 230/400V 50Hz up to 4kW, and 400/690V
50Hz for higher powers.
• Cooling of machines and parts.
• Clean air transport.
• Maximum working temperature: carried air
130ºC; environment 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
• Fans for air working high temperatures.
• Hot-dipped galvanised or stainless steel fans.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
THREE PHASE RANGE
Model
R.P.M. max.
MBCA 180 T2 0,55kW
MBCA 180 T2 1,1kW
MBCA 200 T2 1,1kW
MBCA 200 T2 2,2kW
MBCA 220 T2 1,5kW
MBCA 220 T2 3kW
MBCA 250 T2 3kW
MBCA 280 T2 5,5kW
MBCA 280 T2 11kW
MBCA 220 T4 0,18kW
MBCA 220 T4 0,37kW
MBCA 250 T4 0,25kW
MBCA 250 T4 0,55kW
MBCA 280 T4 0,55kW
MBCA 280 T4 0,75kW
MBCA 280 T4 1,1kW
MBCA 310 T4 1,1kW
MBCA 310 T4 1,5kW
MBCA 310 T4 2,2kW
MBCA 350 T4 2,2kW
MBCA 350 T4 3kW
MBCA 350 T4 4kW
MBCA 400 T4 4kW
MBCA 400 T4 5,5kW
MBCA 400 T4 7,5kW
MBCA 450 T4 11kW
MBCA 450 T4 15kW
MBCA 500 T4 15kW
MBCA 500 T4 22kW
MBCA 560 T4 22kW
MBCA 560 T4 37kW
MBCA 310 T6 0,37kW
MBCA 310 T6 0,55kW
MBCA 350 T6 0,75kW
MBCA 350 T6 1,1kW
MBCA 400 T6 1,5kW
MBCA 400 T6 2,2kW
MBCA 450 T6 3kW
MBCA 450 T6 4kW
MBCA 500 T6 4kW
MBCA 500 T6 7,5kW
MBCA 560 T6 7,5kW
MBCA 560 T6 11kW
2800
2800
2800
2800
2800
2870
2870
2900
2930
1400
1400
1400
1400
1400
1400
1400
1400
1400
1430
1430
1430
1440
1440
1440
1440
1460
1460
1460
1470
1470
1475
900
900
910
910
940
940
960
960
960
965
965
970
Max. Curr. (A)
230 400 690
2,33
4,42
4,42
8,61
6,01
11,1
11,1
1,12
1,94
1,44
2,69
2,69
3,48
4,74
4,74
6,31
8,06
8,06
11,7
15,2
15,2
2,13
2,85
4
5,5
6,9
9,7
12,4
16,3
16,3
-
1,35
2,55
2,55
4,98
3,48
6,4
6,4
11
19,8
0,65
1,12
0,83
1,56
1,56
2,01
2,75
2,75
3,65
5
5
6,8
8,8
8,8
12
15
20,9
27,9
27,9
38,5
38,5
66,7
1,23
1,65
2,3
3,2
4
5,6
7,2
9,4
9,4
16,1
16,1
22,4
6,3
11,39
6,9
8,6
12,02
16,04
16,04
22,14
22,14
38,35
9,26
9,26
12,88
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,55
1,1
1,1
2,2
1,5
3
3
5,5
11
0,18
0,37
0,25
0,55
0,55
11
1,1
1,1
1,5
2,2
2,2
3
4
4
5,5
7,5
11
15
15
22
22
37
0,37
0,55
0,75
1,1
1,5
2,2
3
4
4
7,5
7,5
11
1190
1900
1700
3050
2150
3850
3450
4750
7650
1080
1900
1330
2400
2150
3050
3850
3050
4250
6150
4750
6150
8500
7650
9500
12000
12000
19000
17000
24200
21600
34200
2400
3850
4250
5400
6150
8500
9500
12000
10800
17000
15300
21600
74
76
78
79
80
81
87
89
90
63
63
64
66
68
70
70
73
74
74
76
77
78
81
82
82
83
85
87
89
89
90
63
64
66
68
68
71
73
74
78
80
81
82
18
21
30
37
36
47
49
72
78
28
30
34
37
42
44
46
57
60
62
76
78
87
109
98
119
129
168
187
227
236
382
50
53
70
72
93
99
114
130
174
187
199
212
R.R.P.
€
536,80
594,00
693,00
742,60
752,50
851,80
934,90
1.244,60
1.616,70
642,50
669,50
733,40
786,00
841,40
856,90
884,90
952,10
970,70
1.032,70
1.123,80
1.151,70
1.232,30
1.430,20
1.600,70
1.690,20
2.259,70
2.359,70
2.680,20
3.087,10
3.522,50
4.496,50
908,00
919,50
1.043,20
1.064,90
1.343,40
1.432,60
1.827,50
1.901,90
2.222,50
2.580,20
3.015,60
3.115,60
85
CENTRIFUGAL MEDIUM PRESSURE FANS
MBC/FA
Forward impeller, cubic casing
MANUFACTURING FEATURES
• Reinforced rolling steel sheet housings completely
welded (internally and externally) with epoxy powder
finishing coat.
• Forward curved reinforced impeller.
• Standard asynchronous squirrel-cage motor with IP55 protection and Class F insulation. Manufactured
with standard voltages: 230V 50Hz in single phase
motors and 230/400V 50Hz in three phase motors
up to 4kW, and 400/690V 50Hz for higher powers.
peratures.
• Clean air transport.
• Maximum working temperature: carried air up
to 250ºC; environment: single phase 50ºC, three
phase 60ºC.
UNDER REQUEST
• Drain plug and inspection door.
• 60Hz fans and special voltages.
• Hot air transport.
• 2 speed motors.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Smoke emergency exhaust with motor outside the
hazardous area.
• Hot air exhaust in ovens or facilities with high tem-
ACCESSORIES
RFS
INT
PE
AC
EI
BA-400
SIL-C
SIL-R
SINGLE PHASE RANGE
Code
Model
R.P.M.
max.
Max. Curr. (A)
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
253310173
253300173
253380173
MBC/FA 25/10 M4 1,1kW
MBC/FA 25/10 M6 0,55kW
MBC/FA 28/11 M6 0,75kW
1400
900
900
7,45
3,84
4,97
1,1
0,55
0,75
3500
1900
3600
70
62
60
63
61
67
R.R.P.
€
830,30
810,60
870,80
THREE PHASE RANGE
Code
253310186
253300186
253360186
253370186
253380186
253460186
253450186
253430186
253480186
253490186
253470186
253510186
253520186
253500186
253530186
253540186
253560186
86
Model
MBC/FA 25/10 T4 1,1kW
MBC/FA 25/10 T6 0,55kW
MBC/FA 28/11 T2 4kW
MBC/FA 28/11 T4 2,2kW
MBC/FA 28/11 T6 0,75kW
MBC/FA 31/12 T4 3kW
MBC/FA 31/12 T4 4kW
MBC/FA 31/12 T6 1,5kW
MBC/FA 35/14 T4 3kW
MBC/FA 35/14 T4 5,5kW
MBC/FA 35/14 T6 1,5kW
MBC/FA 40/16 T4 5,5kW
MBC/FA 40/16 T4 7,5kW
MBC/FA 40/16 T6 2,2kW
MBC/FA 45/18 T4 5,5kW
MBC/FA 45/18 T4 7,5kW
MBC/FA 45/18 T6 2,2kW
R.P.M.
max.
1400
900
2890
1430
910
1430
1440
940
1430
1440
940
1440
1440
940
1440
1440
940
Max. Curr. (A)
230 400
690
4,74
2,85
14,2
8,06
4
11,7
15,2
6,9
11,7
6,9
9,7
9,7
2,75
1,65
8,2
5
2,3
6,8
8,8
4
6,8
12
4
12
15
5,6
12
15
5,6
6,9
6,9
8,6
6,9
8,6
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,1
0,55
4
2,2
0,75
3
4
1,5
3
5,5
1,5
5,5
7,5
2,2
5,5
7,5
2,2
3500
1900
4000
5000
3600
5700
6800
4500
6000
8700
5500
9000
10500
7000
8000
11000
9000
70
62
81
82
60
72
73
66
78
79
70
78
79
71
80
82
76
64
63
66
75
69
72
73
71
75
79
73
87
89
86
91
93
90
R.R.P.
€
786,00
739,40
1.020,70
942,40
833,80
1.298,80
1.341,30
1.131,70
1.245,90
1.459,60
1.190,20
1.643,60
1.851,70
1.404,20
1.799,10
2.007,30
1.538,70
CENTRIFUGAL MEDIUM PRESSURE FANS
MA P/R
Radial impeller, aluminium cast
MANUFACTURING FEATURES
• Cast aluminium housing.
• Straight blade steel sheet or cast aluminium impellers.
• Epoxy powder finishing coat.
• Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard
voltages 230/400V 50Hz.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Solid material transport (except for textile fibers).
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
ACCESSORIES
RFS
INT
PE
AC
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Code
Model
R.P.M. max.
253300160
300006000
300140600
300032600
MA 26 T2 0,37kW P/R
MA 27 T2 0,55kW P/R
MA 28 T2 0,75kW P/R
MA 31 T2 1,5kW P/R
2800
2800
2800
2800
Max. Curr. (A)
230
400
1,65
2,33
3,03
6,01
0,95
1,35
1,75
3,48
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,37
0,55
0,75
1,5
700
850
1400
1800
75
80
81
83
14
16
21
25
R.R.P.
€
485,40
559,60
707,20
915,20
87
CENTRIFUGAL MEDIUM PRESSURE FANS
MB P/R
Radial impeller
MANUFACTURING FEATURES
• Rolled steel sheet housing.
• Single inlet straight blade impeller manufactured
in steel sheet and with reinforced with a welded ring
protected with epoxy powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and rated class F insulation. Manufactured with standard voltages 230V 50Hz for
single phase motors and 230/400V 50Hz in three
phase motors up to 4kW, and 400/690V 50Hz for
higher powers.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof and explosionproof fans with ATEX
certified motors.
• Hot-dipped galvanised or stainless steel fans.
• Fans provided with cooling disk for high temperatures. 120€ additional cost.
• Fans for air working temperatures up to 250ºC.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Solid material transport (except for textile fibers).
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
ACCESSORIES
RFS
INT
PE
AC
EI
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
88
Code
Model
R.P.M. max.
253210160
253280160
253360161
253450160
253480161
253510160
253530160
253530161
MB 22/9 T2 1,1kW P/R
MB 25/10 T2 1,5kW P/R
MB 28/11 T2 2,2kW P/R
MB 31/12 T2 3kW P/R
MB 35/14 T2 5,5kW P/R
MB 40/16 T2 7,5kW P/R
MB 45/18 T2 11kW P/R
MB 45/18 T2 15kW P/R
2800
2800
2800
2870
2900
2900
2930
2930
Max. Curr. (A)
230 400 690
4,42
6,01
8,61
11,1
-
2,55
3,48
4,98
6,4
11
15
19,8
26,6
6,3
8,6
11,39
15,3
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,1
1,5
2,2
3
5,5
7,5
11
15
2100
2850
4500
5300
7800
9500
10500
12500
70
74
76
79
84
90
92
95
23
31
40
55
85
103
180
191
R.R.P.
€
828,80
886,70
967,20
1.250,80
1.683,90
1.874,00
2.482,30
3.035,90
CENTRIFUGAL MEDIUM PRESSURE FANS
MBZM P/R
Radial impeller
MANUFACTURING FEATURES
• Rolled steel sheet housing.
• Fully welded and reinforced housing.
• Single inlet straight blade impeller manufactured
in steel sheet with epoxy powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors,
230/400V 50Hz for three phase, motors up to 4kW
and 400/690V 50Hz for higher powers.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
• Fan for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Solid material and textile fibers transport.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
ACCESSORIES
RFS
INT
PE
AC
EI
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Model
R.P.M. max.
MBZM 220 T2 0,37kW P/R
MBZM 251 T2 0,55kW P/R
MBZM 252 T2 0,75kW P/R
MBZM 281 T2 1,1kW P/R
MBZM 282 T2 1,5kW P/R
MBZM 311 T2 1,5kW P/R
MBZM 312 T2 2,2kW P/R
MBZM 351 T2 3kW P/R
MBZM 352 T2 4kW P/R
MBZM 401 T2 5,5kW P/R
MBZM 402 T2 7,5kW P/R
MBZM 452 T2 11kW P/R
MBZM 501 T2 15kW P/R
MBZM 502 T2 22kW P/R
MBZM 454 T4 1,5kW P/R
MBZM 503 T4 2,2kW P/R
MBZM 504 T4 3kW P/R
MBZM 561 T4 4kW P/R
MBZM 562 T4 5,5kW P/R
MBZM 631 T4 7,5kW P/R
MBZM 632 T4 11kW P/R
MBZM 711 T4 11kW P/R
MBZM 712 T4 15kW P/R
MBZM 801 T4 18,5kW P/R
MBZM 802 T4 30kW P/R
MBZM 901 T4 37kW P/R
MBZM 902 T4 45kW P/R
MBZM 1001 T4 60kW P/R
MBZM 1002 T4 75kW P/R
2800
2800
2800
2800
2800
2800
2800
2870
2890
2900
2900
2930
2930
2940
1400
1430
1430
1440
1440
1440
1460
1460
1460
1465
1475
1475
1475
1480
1480
Max. Curr. (A)
230 400 690
1,65
2,33
3,03
4,42
6,01
6,01
8,61
11,1
14,2
6,31
8,06
11,7
15,2
-
0,95
1,35
1,75
2,55
3,48
3,48
4,98
6,4
8,2
11
15
19,8
26,6
39
3,65
5
6,8
8,8
12
15
20,9
20,9
27,9
33
53,2
66,7
78,6
96,2
130
6,3
8,6
11,39
15,3
22,43
6,9
8,6
12,02
12,02
16,04
18,98
30,59
38,35
45,2
55,32
74,75
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,37
0,55
0,75
1,1
1,5
1,5
2,2
3
4
5,5
7,5
11
15
22
1,5
2,2
3
4
5,5
7,5
11
11
15
18,5
30
37
45
55
75
1116
1116
1548
1548
2196
2196
3096
3096
4320
4320
6120
8280
8280
11880
4320
4320
6120
6120
8280
8280
11880
11880
16920
16920
23760
23760
33840
33840
46800
69
71
72
73
74
76
77
79
80
83
84
87
90
91
71
72
74
75
76
78
80
83
84
85
87
90
92
96
97
11
26
29
33
37
43
46
74
80
109
115
198
222
274
106
126
134
148
175
200
274
338
368
443
509
598
638
800
918
R.R.P.
€
493,60
548,70
590,50
689,00
716,90
760,40
782,20
1.022,00
1.087,10
1.521,60
1.577,40
2.139,10
2.390,30
2.855,80
1.425,90
1.697,60
1.725,60
2.581,90
2.752,40
3.249,50
3.573,60
4.329,50
4.429,50
5.262,00
5.909,20
7.567,60
7.898,70
9.296,90
10.369,40
89
CENTRIFUGAL MEDIUM PRESSURE FANS
MBR
Backward impeller
MANUFACTURING FEATURES
• Reinforced rolling steel sheet housings with epoxy
powder coat finishing.
• Reinforced high efficiency backward curved impeller.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230/400V 50Hz
in three phase motors up to 4kW, and 400/690V
50Hz for higher powers.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motor.
• Flameproof and explosionproof fans with ATEX
certified motors.
• Fans for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean and slightly dusty air transport.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
ACCESSORIES
RFS
INT
PE
AC
EI
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
90
Code
Model
R.P.M.
max.
243310106
243350106
243410106
243400106
243450106
243510106
243500106
243570106
243560106
243650106
243640106
243630106
243730106
243720106
243710106
MBR 31/10 T2 1,1kW
MBR 35/11 T2 2,2kW
MBR 40/12 T2 3kW
MBR 40/12 T4 0,75kW
MBR 45/14 T4 1,1kW
MBR 50/16 T4 1,5kW
MBR 50/16 T6 0,75kW
MBR 56/18 T4 3kW
MBR 56/18 T6 1,5kW
MBR 63/20 T4 5,5kW
MBR 63/20 T6 1,5kW
MBR 63/20 T8 1,1kW
MBR 71/22 T4 7,5kW
MBR 71/22 T6 3kW
MBR 71/22 T8 1,5kW
2800
2800
2870
1400
1400
1400
910
1430
940
1440
940
710
1440
960
710
Max. Curr. (A)
230 400 690
4,42
8,61
11,1
3,48
4,74
6,31
4
11,7
6,9
6,9
5,54
12,4
7,45
2,55
4,98
6,4
2,01
2,75
3,65
2,3
6,8
4
12
4
3,2
15
7,2
4,3
6,9
8,6
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,1
2,2
3
0,75
1,1
1,5
0,75
3
1,5
5,5
1,5
1,1
7,5
3
1,5
4800
6660
8500
5640
7200
9500
7100
13500
9500
19000
12000
8940
25500
17000
12440
81
85
88
73
76
81
71
83
73
84
76
68
87
77
70
55
67
82
71
90
74
69
97
89
155
113
102
256
205
180
R.R.P.
€
1.051,70
1.181,90
1.443,40
1.368,80
1.404,80
1.880,20
1.596,30
2.057,60
2.086,50
2.806,80
2.604,80
2.613,10
3.028,60
3.038,70
2.886,10
CENTRIFUGAL MEDIUM PRESSURE FANS
MBRC/FA
Backward impeller, cubic casing
MANUFACTURING FEATURES
• Reinforced rolling steel sheet housings completely
welded (internally and externally) with epoxy powder finishing coat.
• Reinforced high efficiency backward curved impeller.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V in single phase
motors and 230/400V 50Hz in three phase motors
up to 4kW, and 400/690V 50Hz for higher powers.
• Hot air exhaust in ovens or facilities with high temperatures.
• Clean and slightly dusty air transport.
• Maximum working temperature: carried air up
to 250ºC; environment: single phase 50ºC, three
phase 60ºC.
UNDER REQUEST
• Drain plug and inspection door.
• 60Hz fans and special voltages.
• Hot air transport.
• 2 speed motors.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Smoke emergency exhaust with motor outside the
hazardous area.
ACCESSORIES
RFS
INT
PE
AC
EI
BA-400
SIL-C
SIL-R
SINGLE PHASE RANGE
Code
Model
R.P.M.
max.
Max. Curr.
(A)
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
243400173
243450173
243510173
243500173
MBRC/FA 40/12 M4 0,75kW
MBRC/FA 45/14 M4 1,1kW
MBRC/FA 50/16 M4 1,5kW
MBRC/FA 50/16 M6 0,75kW
1400
1400
1400
910
5,45
7,45
9,83
4,97
0,75
1,1
1,5
0,75
5640
7000
9500
7100
72
73
76
70
71
90
74
69
R.R.P.
€
1.610,30
1.815,30
2.006,70
2.005,60
THREE PHASE RANGE
Code
Model
R.P.M.
max.
243410186
243400186
243450186
243510186
243500186
243570186
243560186
243650186
243640186
243730186
243720186
MBRC/FA 40/12 T2 3kW
MBRC/FA 40/12 T4 0,75kW
MBRC/FA 45/14 T4 1,1kW
MBRC/FA 50/16 T4 1,5kW
MBRC/FA 50/16 T6 0,75kW
MBRC/FA 56/18 T4 3kW
MBRC/FA 56/18 T6 1,5kW
MBRC/FA 63/20 T4 5,5kW
MBRC/FA 63/20 T6 1,5kW
MBRC/FA 71/22 T4 7,5kW
MBRC/FA 71/22 T6 3kW
2870
1400
1400
1400
910
1430
940
1440
940
1440
960
Max. Curr. (A)
230 400
690
11,1
3,48
4,74
6,31
4
11,7
6,9
6,9
12,4
6,4
2,01
2,75
3,65
2,3
6,8
4
12
4
15
7,2
6,9
8,6
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
3
0,75
1,1
1,5
0,75
3
1,5
5,5
1,5
7,5
3
8500
5640
7000
9500
7100
13500
9500
19000
12000
25500
17000
85
72
73
76
70
80
70
83
72
85
77
82
71
90
74
69
97
89
155
113
256
205
R.R.P.
€
1.765,80
1.590,30
1.802,50
2.052,30
1.968,60
2.422,50
2.237,10
3.080,60
2.728,80
3.562,10
3.213,70
91
CENTRIFUGAL MEDIUM PRESSURE FANS
MBRL
Backward impeller
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Fully welded or joined housing.
• High efficiency single inlet backward curved impeller, manufactured in rolled steel sheet and epoxy
powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors,
230/400V 50Hz for three phase, motors up to 4kW
and 400/690V 50Hz for higher powers.
APPLICATIONS
Designed for inline installation, they are suitable for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
ACCESSORIES
92
RFS
INT
PE
AC
EI
• Clean and slightly dusty air transport.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
• Fans for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
• Special motors for frequency regulation (recommended for motor sizes IEC280 and larger).
BA-400
SIL-C
SIL-R
CENTRIFUGAL MEDIUM PRESSURE FANS
THREE PHASE RANGE
Model
R.P.M. max.
MBRL 250 T2 0,55kW
MBRL 280 T2 1,1kW
MBRL 311 T2 2,2kW
MBRL 351 T2 3kW
MBRL 401 T2 4kW
MBRL 402 T2 5,5kW
MBRL 451 T2 7,5kW
MBRL 452 T2 11kW
MBRL 501 T2 15kW
MBRL 502 T2 18,5kW
MBRL 312 T4 0,18kW
MBRL 352 T4 0,37kW
MBRL 403 T4 0,55kW
MBRL 453 T4 0,75kW
MBRL 454 T4 1,1kW
MBRL 503 T4 1,5kW
MBRL 504 T4 2,2kW
MBRL 561 T4 3kW
MBRL 562 T4 4kW
MBRL 631 T4 5,5kW
MBRL 632 T4 7,5kW
MBRL 711 T4 11kW
MBRL 712 T4 15kW
MBRL 801 T4 18,5kW
MBRL 802 T4 22kW
MBRL 901 T4 37kW
MBRL 902 T4 45kW
MBRL 1001 T4 55kW
MBRL 802 T4 75kW
MBRL 505 T6 0,37kW
MBRL 506 T6 0,55kW
MBRL 563 T6 0,75kW
MBRL 564 T6 1,1kW
MBRL 633 T6 1,5kW
MBRL 634 T6 2,2kW
MBRL 713 T6 3kW
MBRL 714 T6 4kW
MBRL 803 T6 5,5kW
MBRL 804 T6 7,5kW
MBRL 903 T6 11kW
MBRL 904 T6 15kW
MBRL 1003 T6 18,5kW
MBRL 1004 T6 22kW
MBRL 1121 T6 30kW
MBRL 1122 T6 37kW
MBRL 1251 T6 55kW
MBRL 1252 T6 75kW
2800
2800
2800
2870
2890
2900
2900
2930
2930
2935
1400
1400
1400
1400
1400
1400
1430
1430
1440
1440
1440
1460
1460
1465
1470
1475
1475
1480
1480
900
900
910
910
940
940
960
960
960
965
970
970
975
975
980
980
980
985
Max. Curr. (A)
230 400
690
2,33
4,42
8,61
11,1
14,2
1,12
1,94
2,69
3,48
4,74
6,31
8,06
11,7
15,2
2,13
2,85
4
5,5
6,9
9,7
12,4
16,3
-
1,35
2,55
4,98
6,4
8,2
11
15
19,8
26,6
32
0,65
1,12
1,56
2,01
2,75
3,65
5
6,8
8,8
12
15
20,9
27,9
33
38,5
66,7
78,6
96,2
130
1,23
1,65
2,3
3,2
4
5,6
7,2
9,4
12,42
16,1
22,4
29,4
34,8
41,4
55,4
67,4
97
133,5
6,3
8,6
11,39
15,3
18,4
6,9
8,6
12,02
16,04
18,98
22,14
38,35
45,2
55,32
74,75
7,17
9,26
12,88
16,91
20,01
23,81
31,86
38,76
55,78
76,76
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,55
1,1
2,2
3
4
5,5
7,5
11
15
18,5
0,18
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
37
45
55
75
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
30
37
55
75
2700
3850
5400
7650
9500
12000
13500
17000
19000
24200
2700
3850
5400
6850
7650
9500
10800
13500
17000
19000
24200
27000
34200
38200
47500
54000
68500
76500
95400
6150
6850
8500
9000
12000
15300
17000
21600
24200
30600
34200
42500
47500
61000
68500
85000
95400
120600
70
72
76
79
82
84
86
88
89
92
57
60
64
65
67
69
71
72
74
75
78
79
82
83
85
86
88
90
93
57
59
60
62
66
68
69
72
73
75
76
78
80
82
83
85
86
88
33
43
52
80
95
108
124
160
187
196
42
65
75
89
94
123
129
141
146
190
204
315
326
402
418
630
650
832
941
115
116
131
133
173
179
276
286
330
368
500
499
697
716
1071
1212
1475
1596
R.R.P.
€
825,70
1.001,70
1.237,30
1.469,20
1.720,30
1.909,40
2.167,10
2.483,40
2.809,80
2.961,50
1.105,50
1.286,90
1.506,30
1.723,70
1.751,60
2.055,10
2.117,10
2.536,90
2.617,50
3.259,00
3.348,40
4.254,30
4.354,40
5.412,40
5.560,70
8.177,10
8.508,20
10.135,90
11.208,40
1.992,40
2.003,90
2.428,40
2.450,00
3.001,60
3.090,90
3.822,20
3.896,60
4.765,00
5.053,80
6.796,20
7.240,80
8.584,40
8.813,90
11.412,10
12.078,70
15.792,60
19.774,90
93
CENTRIFUGAL MEDIUM PRESSURE FANS
MBRLP
Centrifugal medium pressure fan for paint booths
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Fully welded or joined housing.
• Flanged inlet to allow direct join in the paint
shop outlet.
• Inspection door included.
• Cabin fans supplied, if requested, with sparkproof inlet.
• High efficiency single inlet and backward curved
impeller manufactured in rolled steel sheet with
epoxy powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation.
Manufactured with standard voltages: 230/400V
50Hz in three phase motors up to 4kW, and
400/690V 50Hz for higher powers.
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean and slightly dusty air transport.
• Exhaust after filters in paint booths.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motor.
• Flameproof or explosionproof fans with ATEX certified motors.
• Hot-dipped galvanised or stainless steel fans.
APPLICATIONS
Designed to be fixed at the inlet double flange, with
motor in vertical position.
ACCESSORIES
RFS
INT
PE
RA
CP
AC
EI
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Model
MBRLP 454 T4 1,1kW
MBRLP 503 T4 1,5kW
MBRLP 561 T4 3kW
MBRLP 562 T4 4kW
MBRLP 631 T4 5,5kW
MBRLP 632 T4 7,5kW
MBRLP 633 T6 1,5kW
MBRLP 634 T6 2,2kW
MBRLP 713 T6 3kW
MBRLP 714 T6 4kW
94
R.P.M. max.
1400
1400
1430
1440
1440
1440
940
940
960
960
Max. Curr. (A)
230 400
690
4,74
6,31
11,7
15,2
6,9
9,7
12,4
16,3
2,75
3,65
6,8
8,8
12
15
4
5,6
7,2
9,4
6,9
8,6
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,1
1,5
3
4
5,5
7,5
1,5
2,2
3
4
7650
9500
13500
17000
19000
24200
12000
15300
17000
21600
69
71
74
76
77
80
68
70
71
74
54
75
94
98
104
112
92
95
107
113
R.R.P.
€
1.278,40
1.383,50
2.030,80
2.206,30
2.913,20
2.986,30
2.649,30
2.710,80
3.017,40
3.172,30
CENTRIFUGAL MEDIUM PRESSURE FANS
MBRM
Backward impeller, dusty air
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Fully welded or joined housing.
• High efficiency single inlet and backward curved
impeller, manufactured in rolled steel sheet and
epoxy powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and rated class F insulation. Manufactured with standard voltages: 230V 50Hz for single phase motors, 230/400V 50Hz for three phase,
motors up to 4kW and 400/690V 50Hz for higher
powers.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
ACCESSORIES
RFS
INT
PE
RA
AC
EI
• Transport of dusty air and small loads of pellet
materials.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
• Fans for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
• Special motors for frequency regulation (recommended for motor sizes IEC280 and larger).
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Model
R.P.M. max.
MBRM 220 T2 0,18kW
MBRM 251 T2 0,25kW
MBRM 252 T2 0,37kW
MBRM 281 T2 0,55kW
MBRM 282 T2 0,75kW
MBRM 311 T2 1,1kW
MBRM 312 T2 1,5kW
MBRM 351 T2 1,5kW
MBRM 352 T2 2,2kW
MBRM 401 T2 3kW
MBRM 402 T2 4kW
MBRM 451 T2 5,5kW
MBRM 452 T2 7,5kW
MBRM 501 T2 11kW
MBRM 502 T2 15kW
MBRM 561 T2 18,5kW
MBRM 562 T2 22kW
MBRM 503 T4 1,1kW
MBRM 504 T4 1,5kW
MBRM 563 T4 2,2kW
MBRM 564 T4 3kW
MBRM 631 T4 4kW
MBRM 632 T4 5,5kW
MBRM 711 T4 7,5kW
MBRM 712 T4 11kW
MBRM 801 T4 15kW
MBRM 802 T4 18,5kW
MBRM 901 T4 30kW
MBRM 902 T4 37kW
MBRM 1001 T4 45kW
MBRM 1002 T4 55kW
MBRM 1121 T4 75kW
MBRM 1122 T4 90kW
MBRM 803 T6 4kW
MBRM 804 T6 5,5kW
MBRM 903 T6 7,5kW
MBRM 904 T6 11kW
MBRM 1003 T6 15kW
MBRM 1004 T6 18,5kW
MBRM 1123 T6 22kW
MBRM 1124 T6 30kW
MBRM 1251 T6 37kW
MBRM 1252 T6 45kW
2800
2800
2800
2800
2800
2800
2800
2800
2800
2870
2890
2900
2900
2930
2930
2935
2940
1400
1400
1430
1430
1440
1440
1440
1460
1460
1465
1475
1475
1475
1480
1480
1485
960
960
965
970
970
975
975
980
980
980
Max. Curr. (A)
230
400
690
0,91
1,17
1,65
2,33
3,03
4,42
6,01
6,01
8,61
11,1
14,2
4,74
6,31
8,06
11,7
15,2
16,3
-
0,53
1,68
0,95
1,35
1,75
2,55
3,48
3,48
4,98
6,4
8,2
11
15
19,8
26,6
32
39
2,75
3,65
5
6,8
8,8
12
15
20,9
27,9
33
53,2
66,7
78,6
96,2
130
154,8
9,4
12,42
16,1
22,4
29,4
34,8
41,4
55,4
67,4
80,6
6,3
8,6
11,39
15,3
18,4
22,43
6,9
8,6
12,02
16,04
18,98
30,59
38,35
45,2
55,32
74,75
89,01
7,17
9,26
12,88
16,91
20,01
23,81
31,86
38,76
46,35
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,18
0,25
0,37
0,55
0,75
1,1
1,5
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
30
37
45
55
75
90
4
5,5
7,5
11
15
18,5
22
30
37
45
830
1330
1330
1900
1900
2700
2700
3850
3850
6150
6150
8500
8500
12000
12000
15300
15300
5400
5400
8500
8500
12000
12000
17000
17000
24200
24200
34200
34200
47500
42500
68500
68500
15300
15300
21600
21600
30600
30600
42500
42500
61000
61000
64
65
67
69
70
72
73
76
78
80
81
84
85
89
89
91
92
68
69
71
72
75
78
79
81
83
84
86
87
90
91
93
94
73
74
76
77
79
80
82
83
86
87
18
24
26
30
32
41
44
66
69
107
110
150
158
235
247
286
316
132
135
140
144
178
191
285
308
400
430
580
620
760
830
1220
1257
330
340
465
495
652
679
995
1043
1330
1405
R.R.P.
€
491,50
546,40
552,90
655,60
697,30
768,20
796,10
962,30
984,00
1.322,70
1.387,90
1.830,30
1.886,10
2.420,10
2.461,50
3.325,60
3.639,40
1.688,30
1.706,90
2.481,20
2.509,20
3.124,10
3.294,60
4.179,60
4.503,70
5.201,30
5.459,90
7.353,70
7.828,80
8.995,00
9.601,70
12.728,10
13.170,90
4.743,50
4.812,50
6.348,00
6.448,00
7.727,60
8.050,10
10.333,70
10.968,80
13.764,70
14.723,10
95
CENTRIFUGAL MEDIUM PRESSURE FANS
MBRU
Backward impeller, dusty air, large pressures
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Fully welded or joined housing.
• High efficiency single inlet and backward curved
impeller manufactured in rolling steel sheet with
epoxy powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and rated class F insulation. Manufactured with standard voltages: 230V 50Hz for single phase motors, 230/400V 50Hz for three phase
motors up to 4kW, and 400/690V 50Hz for higher
powers.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
• Fans for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
• Special motors for frequency regulation (recommended for motor sizes IEC280 and larger).
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Transport of dusty air and small loads of pellet
materials.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
ACCESSORIES
RFS
INT
PE
RA
AC
EI
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Model
MBRU 250 T2 0,37kW
MBRU 280 T2 0,55kW
MBRU 310 T2 1,1kW
MBRU 350 T2 2,2kW
MBRU 400 T2 4kW
MBRU 450 T2 7,5kW
MBRU 501 T2 11kW
MBRU 561 T2 15kW
MBRU 562 T2 18,5kW
MBRU 631 T2 30kW
MBRU 632 T2 37kW
MBRU 502 T4 1,1kW
MBRU 563 T4 2,2kW
MBRU 633 T4 4kW
MBRU 711 T4 5,5kW
MBRU 712 T4 7,5kW
MBRU 801 T4 11kW
MBRU 802 T4 15kW
MBRU 901 T4 18,5kW
MBRU 902 T4 30kW
MBRU 1001 T4 37kW
MBRU 1002 T4 45kW
MBRU 1121 T4 55kW
MBRU 1122 T4 75kW
MBRU 1251 T4 110kW
MBRU 1252 T4 132kW
MBRU 803 T6 4kW
MBRU 903 T6 7,5kW
MBRU 1003 T6 11kW
MBRU 1004 T6 15kW
MBRU 1123 T6 18,5kW
MBRU 1124 T6 22kW
MBRU 1253 T6 30kW
MBRU 1254 T6 37kW
96
R.P.M. max.
2800
2800
2800
2800
2890
2900
2930
2930
2935
2950
2955
1400
1430
1440
1440
1440
1460
1460
1465
1475
1475
1475
1480
1480
1485
1485
960
965
970
970
975
975
980
980
Max. Curr. (A)
230
400
690
1,65
2,33
4,42
8,61
14,2
4,74
8,06
15,2
16,3
-
0,95
1,35
2,55
4,98
8,2
15
19,8
26,6
32
52,6
64,3
2,75
5
8,8
12
15
20,9
27,9
33
53,2
66,7
78,6
96,2
130
188,6
225,1
9,4
16,1
22,4
29,4
34,8
41,4
55,4
67,4
8,6
11,39
15,3
18,4
30,25
36,97
6,9
8,6
12,02
16,04
18,98
30,59
38,35
45,2
55,32
74,75
108,45
129,43
9,26
12,88
16,91
20,01
23,81
31,86
38,76
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,37
0,55
1,1
2,2
4
7,5
11
15
18,5
30
37
1,1
2,2
4
5,5
7,5
11
15
18,5
30
37
45
55
75
110
132
4
7,5
11
15
18,5
22
30
37
1330
1900
2700
3850
5400
7650
10800
13500
15300
19000
21600
5400
7650
10800
13500
15300
19000
21600
27000
30600
38200
42500
54000
61800
76500
85000
15300
21600
27000
30600
38200
42500
54000
61800
61
64
68
71
75
78
82
84
85
88
89
63
67
71
73
74
77
78
80
81
84
85
87
88
91
92
67
70
74
75
77
78
80
81
25
30
40
67
105
150
230
282
292
380
390
128
138
175
270
281
327
397
416
671
749
759
1140
1212
1470
1530
337
486
612
642
967
987
1220
1316
R.R.P.
€
608,30
718,90
835,40
1.075,00
1.506,60
2.040,40
2.602,20
3.439,10
3.590,80
4.971,00
5.180,60
1.870,30
2.746,40
3.452,60
4.517,60
4.607,00
5.762,20
5.862,20
7.569,40
8.216,50
9.657,30
9.988,40
12.981,50
14.054,00
19.640,80
20.478,90
5.404,50
7.210,70
8.276,40
8.721,00
11.429,90
11.659,50
14.760,30
15.426,90
CENTRIFUGAL MEDIUM PRESSURE FANS
MBGR
Backward impeller, dusty air, large pressures
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Fully welded or joined housing.
• High efficiency single inlet and backward curved
impeller, manufactured in rolled steel sheet and
epoxy powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and rated class F insulation. Manufactured with standard voltages: 230V 50Hz for single phase motors, 230/400V 50Hz for three phase,
motors up to 4kW and 400/690V 50Hz for higher
powers.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
• Fans for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
• Special motors for frequency regulation (recommended for motor sizes IEC280 and larger).
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Transport of dusty air and small loads of pellet
materials.
ACCESSORIES
RFS
INT
PE
RA
AC
EI
BA-400
SIL-C
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
2,2
3
4
5,5
7,5
11
11
15
22
30
37
45
75
90
132
160
1,5
2,2
3
4
4
5,5
7,5
11
15
22
30
37
45
55
75
110
4
5,5
7,5
11
15
18,5
22
30
3050
4750
4250
6850
6150
9500
8500
13500
12000
19000
17000
27000
24200
38200
34200
54000
4250
6850
6150
9500
8500
13500
12000
19000
17000
27000
24200
38200
34200
54000
47500
76500
10800
17000
15300
24200
21600
34200
30600
47500
77
78
80
83
84
86
89
89
89
90
93
94
94
96
98
98
67
69
71
72
74
75
77
80
80
81
85
86
87
89
91
92
68
70
72
73
75
75
78
78
73
81
99
112
145
203
227
240
311
364
440
481
603
694
938
964
137
144
147
155
246
258
331
389
478
534
671
713
985
1056
1356
1392
388
399
556
587
825
906
1111
1182
SIL-R
THREE PHASE RANGE
Model
R.P.M.
max.
230
MBGR 401 T2 2,2kW
MBGR 402 T2 3kW
MBGR 451 T2 4kW
MBGR 452 T2 5,5kW
MBGR 501 T2 7,5kW
MBGR 502 T2 11kW
MBGR 561 T2 11kW
MBGR 562 T2 15kW
MBGR 631 T2 22kW
MBGR 632 T2 30kW
MBGR 711 T2 37kW
MBGR 712 T2 45kW
MBGR 801 T2 75kW
MBGR 802 T2 90kW
MBGR 901 T2 132kW
MBGR 902 T2 160kW
MBGR 563 T4 1,5kW
MBGR 564 T4 2,2kW
MBGR 633 T4 3kW
MBGR 634 T4 4kW
MBGR 713 T4 4kW
MBGR 714 T4 5,5kW
MBGR 803 T4 7,5kW
MBGR 804 T4 11kW
MBGR 903 T4 15kW
MBGR 904 T4 22kW
MBGR 1001 T4 30kW
MBGR 1002 T4 37kW
MBGR 1121 T4 45kW
MBGR 1122 T4 55kW
MBGR 1251 T4 75kW
MBGR 1252 T4 110kW
MBGR 905 T6 4kW
MBGR 906 T6 5,5kW
MBGR 1003 T6 7,5kW
MBGR 1004 T6 11kW
MBGR 1123 T6 15kW
MBGR 1124 T6 18,5kW
MBGR 1253 T6 22kW
MBGR 1254 T6 30kW
2800
2870
2890
2900
2900
2930
2930
2930
2940
2950
2955
2960
2965
2970
2980
2980
1400
1430
1430
1440
1440
1440
1440
1460
1460
1470
1475
1475
1475
1480
1480
1485
960
960
965
970
970
975
975
980
8,61
11,1
14,2
6,31
8,06
11,7
15,2
15,2
16,3
-
Max. Curr. (A)
400
690
4,98
6,4
8,2
11
15
19,8
19,8
26,6
39
52,6
64,3
77,1
126,6
151,7
219,9
263,1
3,65
5
6,8
8,8
8,8
12
15
20,9
27,9
38,5
53,2
66,7
78,6
96,2
130
188,6
9,4
12,42
16,1
22,4
29,4
34,8
41,4
55,4
6,3
8,6
11,39
11,39
15,3
22,43
30,25
36,97
44,33
72,8
87,23
126,44
151,28
6,9
8,6
12,02
16,04
22,14
30,59
38,35
45,2
55,32
74,75
108,45
7,17
9,26
12,88
16,91
20,01
23,81
31,86
R.R.P.
€
1.367,90
1.445,40
1.748,00
1.937,20
2.238,30
2.554,70
3.132,50
3.173,90
4.541,80
5.010,60
5.952,30
6.721,40
8.605,90
9.624,90
15.127,60
15.827,40
2.419,30
2.481,20
3.411,50
3.492,20
4.224,30
4.394,90
5.291,70
5.615,80
6.732,90
7.139,80
8.303,60
8.778,70
11.381,50
11.988,10
16.404,80
19.526,00
6.275,20
6.344,20
7.297,80
7.397,80
10.114,10
10.436,60
14.010,40
14.645,50
97
CENTRIFUGAL MEDIUM PRESSURE FANS
MBRH
Backward impeller with no casing, air recirculation in ovens
MANUFACTURING FEATURES
• Fan including high efficiency single inlet and
backward curved impeller, insulated wall, wall support, cooling wheel, and motor.
• Insulated thickness and wall support fully welded
and adapted to the customer needs.
• Special coat finishing for high temperature applications.
• Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors,
230/400V 50Hz for three phase, motors up to 4kW
and 400/690V 50Hz for higher powers.
• Default assembly position is LG270.
ACCESSORIES
RFS
INT
APPLICATIONS
• Air recirculation in ovens.
• Maximum working temperature: carried air
250ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Operation in high temperatures
• Stainless steel fans.
AC
THREE PHASE RANGE
Model
R.P.M. max.
MBRH 402 T4 0,75kW
MBRH 452 T4 1,1kW
MBRH 454 T4 1,5kW
MBRH 504 T4 2,2kW
MBRH 561 T4 3kW
MBRH 562 T4 4kW
MBRH 631 T4 5,5kW
MBRH 711 T4 7,5kW
MBRH 712 T4 11kW
MBRH 713 T4 15kW
MBRH 801 T4 18,5kW
MBRH 802 T4 22kW
MBRH 901 T4 30kW
MBRH 902 T4 37kW
MBRH 903 T4 45kW
MBRH 403 T6 0,37kW
MBRH 454 T6 0,75kW
MBRH 503 T6 1,1kW
MBRH 634 T6 2,2kW
MBRH 714 T6 3kW
MBRH 715 T6 4kW
MBRH 803 T6 7,5kW
MBRH 804 T6 11kW
1400
1400
1400
1430
1430
1440
1440
1440
1460
1460
1465
1470
1475
1475
1475
900
910
910
940
960
960
960
970
98
Max. Curr. (A)
230
400
690
3,48
4,74
6,31
8,06
11,7
15,2
2,13
4
5,5
9,7
12,4
16,3
-
2,01
2,75
3,65
5
6,8
8,8
12
15
20,9
27,9
33
38,5
53,2
66,7
78,6
1,23
2,3
3,2
5,6
7,2
9,4
12,42
22,4
6,9
8,6
12,02
16,04
18,98
22,14
30,59
38,35
45,2
7,17
12,88
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
30
37
40
0,37
0,75
1,1
2,2
3
4
7,5
11
5400
7650
8500
10800
13500
17000
19000
24200
27000
34200
38200
47500
50000
54000
68500
4500
5300
6200
13500
17000
21600
27000
30600
67
70
73
75
77
79
80
82
84
85
86
88
90
92
94
63
66
67
70
73
76
78
81
56,07
60,9
64,05
82,425
90,93
95,13
133,245
150,78
179,13
196,98
244,755
263,655
228,48
292,005
321,405
57,645
69,3
84,525
126,945
149,73
159,18
256,305
269,955
R.R.P.
€
2.491,90
3.032,50
3.055,30
3.376,70
3.694,40
3.762,40
4.367,30
4.915,70
5.278,60
5.410,90
6.235,30
6.310,90
8.594,80
8.972,90
9.218,80
2.529,70
3.051,50
3.346,40
4.405,10
4.885,40
4.991,30
5.917,70
6.050,00
CENTRIFUGAL MEDIUM PRESSURE FANS
MDI
Forward impeller, stainless steel AISI 304
MANUFACTURING FEATURES
• Welded stainless steel AISI 304 housing.
• Stainless steel single inlet forward curved impeller.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof and explosionproof fans with
ATEX certified motors.
• Fans provided with cooling disk for high temperatures.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean air transport.
• Corrosive air transport.
• Maximum working temperature: carried air
130ºC; environment: single phase 50ºC, three
phase 60ºC.
ACCESSORIES
REG
RFS
INT
PE
RAI
SINGLE PHASE RANGE
Code
Model
R.P.M. max.
300716100
300716200
300716300
300716400
300716500
300716600
300716700
300716800
300716900
300717000
300717100
300717200
300717300
MDI 10/5 M2 0,1kW
MDI 12/6 M2 0,12kW
MDI 13/6 M2 0,18kW
MDI 13/6 M4 0,12kW
MDI 13/8 M4 0,12kW
MDI 13/8 M2 0,37kW
MDI 16/8 M2 0,25kW
MDI 16/8 M4 0,12kW
MDI 18/8 M2 0,55kW
MDI 18/8 M4 0,18kW
MDI 20/10 M2 1,1kW
MDI 20/10 M4 0,25kW
MDI 25/13 M4 0,55kW
2760
2770
2800
1400
1400
2800
2800
1400
2800
1400
2800
1400
1400
Max. Curr. (A)
230
400
0,81
0,98
1,48
1,1
1,1
2,73
1,96
1,1
3,88
1,62
7,02
2,02
4,25
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,09
0,12
0,18
0,12
0,12
0,37
0,25
0,12
0,55
0,18
1,1
0,25
0,55
370
500
508
416
500
1275
900
835
1600
1266
3500
1600
3000
66
69
53
71
52
74
74
56
78
56
78
58
72
2,4
2,8
4,9
5,3
5,8
9,4
6,2
9
10,2
9,7
19
11
24
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,09
0,12
0,18
0,12
0,12
0,37
0,25
0,12
0,55
0,18
1,1
0,25
2,2
0,55
370
500
508
416
500
1275
900
835
1600
1266
3500
1600
3350
3000
66
69
71
53
52
74
74
56
78
56
78
58
85
72
2,4
2,8
5,3
4,9
5,8
9,4
6,2
9
10,2
9,7
19
11
32
24
R.R.P.
€
503,20
558,30
566,10
566,10
603,80
591,20
735,90
710,70
767,40
729,70
943,50
830,20
1.660,60
THREE PHASE RANGE
Code
Model
R.P.M. max.
300717600
300717700
300717800
300717900
300718000
300718100
300718200
300718300
300718400
300718500
300718600
300718700
300718800
300718900
MDI 10/5 T2 0,1kW
MDI 12/6 T2 0,12kW
MDI 13/6 T2 0,18kW
MDI 13/6 T4 0,12kW
MDI 13/8 T4 0,12kW
MDI 13/8 T2 0,37kW
MDI 16/8 T2 0,25kW
MDI 16/8 T4 0,12kW
MDI 18/8 T2 0,55kW
MDI 18/8 T4 0,18kW
MDI 20/10 T2 1,1kW
MDI 20/10 T4 0,25kW
MDI 25/13 T2 2,2kW
MDI 25/13 T4 0,55kW
2800
2800
2800
1400
1400
2800
2800
1400
2800
1400
2800
1400
2800
1400
Max. Curr. (A)
230
400
0,57
0,67
0,91
0,84
0,84
1,65
1,17
0,84
2,33
1,12
4,42
1,44
8,61
2,69
0,33
0,38
0,53
0,48
0,48
0,95
1,68
0,48
1,35
0,65
2,55
0,83
4,98
1,56
R.R.P.
€
459,20
498,90
506,40
506,40
537,80
531,50
676,20
651,00
691,90
660,40
830,20
754,80
1.673,20
1.534,70
99
CENTRIFUGAL MEDIUM PRESSURE FANS
MBP
Backward impeller, anticorrosive plastic material
MANUFACTURING FEATURES
• PE plastic housing.
• Backward curved impeller in PP plastic.
• Motor support made of rolled steel sheet with
epoxy powder finishing coat.
• Stainless steel nuts and bolts.
• Standard asynchronous squirrel-cage motor, IP55, class F insulation. Standard voltages 230/400V
50Hz.
• ATEX models equipped with II2G Eex-d motors.
UNDER REQUEST
• Single phase motors (up to 1,5kW).
• 60Hz fans and special voltages fans.
• 2 speed motors.
• Stainless steel motor support.
• Casing made of PP, PPS, PPel, PEs. Impeller made
of PPs, PVDF.
• Sparkproof fans with certified ATEX Eex-d.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Corrosive air transport.
• Chemical and petrochemical industry.
• Laboratories and gas cabinets.
• Maximum working temperature: 50ºC.
ACCESSORIES
RFS
INT
THREE PHASE RANGE
Code
243200170
243250170
243260170
243310170
243320170
243350170
243360170
243400170
243410170
243450170
243460170
100
Model
MBP 20 T2 1/4
MBP 20 T4 1/6
MBP 25 T2 1/2
MBP 25 T4 1/6
MBP 31 T2 2
MBP 31 T4 1/3
MBP 31 T6 1/4
MBP 35 T2 3
MBP 35 T4 1/2
MBP 35 T6 1/4
MBP 40 T4 3/4
MBP 40 T6 1/3
MBP 45 T2 5,5
MBP 45 T4 1,5
MBP 45 T6 1/2
R.P.M. max.
2800
1400
2800
1400
2800
1400
880
2800
1400
880
1400
900
2890
1400
900
Max. Curr. (A)
230
400
0,9
0,74
2,1
0,74
5,3
1,4
1,2
6,9
2,1
1,2
2,45
1,4
14,9
4,65
2,1
0,6
0,43
1,2
0,43
3,4
0,81
0,7
4
1,2
0,7
1,42
0,81
8,61
2,69
1,2
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,18
0,12
0,37
0,12
1,5
0,25
0,18
2,2
0,37
0,18
0,55
0,25
4
1,1
0,37
1100
550
2500
1000
4500
2250
1500
6800
3400
2250
4750
2375
12000
6000
4250
63
47
68
53
76
61
50
76
60
54
68
56
82
64
56
9
9
13
10
26
19
19
32
23
23
33
30
52
41
37
R.R.P.
€
638,00
638,00
870,70
823,90
1.366,50
1.127,30
1.123,30
1.531,80
1.263,40
1.259,20
1.727,30
1.563,30
3.089,50
1.945,30
1.702,80
CENTRIFUGAL MEDIUM PRESSURE FANS
MBPC
Forward impeller, anticorrosive plastic material
MANUFACTURING FEATURES
• PE plastic housing (antistatic PE-el for ATEX units).
• Forward curved impeller in PP plastic.
• Motor support made of rolled steel sheet with
epoxy powder finishing coat.
• Stainless steel nuts and bolts.
• Standard asynchronous squirrel-cage motor, IP55, class F insulation. Standard voltages 230/400V
50Hz.
UNDER REQUEST
• Single phase motors (up to 1,5kW).
• 60Hz fans and special voltages fans.
• 2 speed motors.
• Sparkproof fans with certified ATEX Eex-d.
• Stainless steel motor support.
• Casing made of PP, PPS, PPel, PEs.
• Impeller made of PPs, PVDF.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Corrosive air transport.
• Chemical and petrochemical industry.
• Laboratories and gas cabinets.
• Maximum working temperature: 50ºC.
ACCESSORIES
RFS
INT
PE
THREE PHASE RANGE
Code
Model
R.P.M.
max.
300725400
300725500
300725600
300725700
300725800
300725900
300726000
300726100
300726200
300726300
300726400
300726500
300726600
300726700
300726800
300728800
300726900
300727000
300727100
300727200
300727300
300727400
MBPC 20 T2 0,25kW
MBPC 20 T4 0,12kW
MBPC 25 T2 0,75kW
MBPC 25 T4 0,18kW
MBPC 28 T2 1,1kW
MBPC 28 T4 0,18kW
MBPC 31 T2 1,5kW
MBPC 31 T4 0,25kW
MBPC 31 T6 0,12kW
MBPC 35 T2 2,2kW
MBPC 35 T4 0,37kW
MBPC 40 T2 5,5kW
MBPC 40 T2 4kW
MBPC 40 T4 0,75kW
MBPC 40 T6 0,25kW
MBPC 45 T2 9kW
MBPC 45 T4 1,1kW
MBPC 45 T6 0,37kW
MBPC 50 T4 2,2kW
MBPC 50 T6 0,75kW
MBPC 56 T4 5,5kW
MBPC 56 T6 2,2kW
2800
1400
2800
1400
2800
1400
2800
1400
850
2800
1400
2900
2890
1400
900
2800
1400
900
1430
910
1440
940
Max. Curr. (A)
230
400
690
1,17
0,84
3,03
0,84
4,42
1,12
6,01
1,44
1,08
8,61
1,94
14,2
3,48
1,51
4,74
2,13
8,06
4
9,7
1,68
0,48
1,75
0,48
2,55
0,65
3,48
0,83
0,62
4,98
1,12
11
8,2
2,01
0,87
16,7
2,75
1,23
5
2,3
12
5,6
6,3
9,6
6,9
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,25
0,12
0,75
0,18
1,1
0,18
1,5
0,25
0,12
2,2
0,37
5,5
4
0,75
0,25
9
1,1
0,37
2,2
0,75
5,5
2,2
800
440
1500
780
2100
1100
2510
1400
920
2820
1970
5590
4080
2710
1930
7640
3650
2700
5440
4090
9150
8100
74
59
80
64
85
69
90
73
64
88
72
91
91
76
65
93
78
68
80
70
82
71
18
9
29
21
20
16
31
24
20
50
40
49
47
31
28
65
65
65
100
90
115
95
R.R.P.
€
540,00
536,40
709,40
622,10
863,30
760,00
1.043,80
891,40
906,70
1.554,70
1.516,90
1.729,50
1.636,00
1.246,50
1.199,70
4.540,50
3.287,60
3.194,20
3.856,40
3.794,00
5.180,80
4.869,20
101
CENTRIFUGAL MEDIUM PRESSURE FANS
GROUP
Free shaft without motor or belt driven motor in different configurations
MANUFACTURING FEATURES
• Rolling steel sheet housing, fully welded and protected against corrosion with epoxy powder finishing coat.
• Galvanised sheet (MZCA) or rolling steel sheet
impeller (rest of ranges) protected against corrosion
with epoxy powder finishing coat.
• Supplied with free shaft, i.e. without motor, pulleys
nor belts.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean air and pneumatic transport.
• Clean air or slightly dusty air transport (MZRL).
• Transport of dusty air or with low load of granulated materials (MZRM y MZRU).
• Solid material transport and textile fibers (MZZM
P/R).
Size
220
250
280
310
350
400
450
500
560
630
710
800
900
1000
1120
Size
220
250
280
310
350
400
450
500
560
630
710
800
900
1000
Size
220
250
280
310
350
400
450
500
560
630
710
800
900
1000
1120
102
MZRM
1.004,90 €
1.160,10 €
1.276,50 €
1.501,60 €
1.769,30 €
1.940,00 €
2.172,80 €
2.685,00 €
3.383,40 €
4.109,00 €
5.203,20 €
5.827,90 €
7.333,30 €
8.629,30 €
11.500,50 €
MZRM
1.327,00 €
1.482,20 €
1.606,30 €
1.846,90 €
2.118,50 €
2.351,30 €
2.584,10 €
3.305,80 €
4.062,40 €
4.896,60 €
5.986,90 €
6.759,10 €
8.264,60 €
9.603,20 €
MZRM
1.544,30 €
1.699,50 €
1.839,20 €
2.157,30 €
2.471,60 €
2.902,30 €
3.135,10 €
3.798,60 €
4.803,50 €
5.630,00 €
7.096,60 €
7.822,20 €
9.669,10 €
11.190,10 €
14.383,40 €
MZRU
1.295,90 €
1.420,10 €
1.668,40 €
1.971,10 €
2.161,20 €
2.417,30 €
2.987,70 €
3.771,40 €
4.586,20 €
5.812,30 €
6.731,90 €
8.481,80 €
10.002,80 €
13.335,80 €
MZRU
1.618,00 €
1.749,90 €
2.013,80 €
2.669,50 €
2.572,50 €
2.828,60 €
3.608,50 €
5.187,70 €
5.366,10 €
6.592,20 €
7.659,30 €
9.413,10 €
10.976,70 €
MZRU
1.839,20 €
1.982,70 €
2.324,20 €
2.316,40 €
3.123,50 €
3.383,40 €
4.101,20 €
4.446,60 €
6.099,50 €
7.698,10 €
8.730,20 €
10.817,60 €
12.567,50 €
16.214,80 €
MZRL
1.218,30 €
1.311,50 €
1.521,00 €
1.815,90 €
1.994,40 €
2.238,80 €
2.770,40 €
3.558,00 €
4.252,60 €
5.210,90 €
6.095,60 €
7.387,70 €
9.153,10 €
11.927,30 €
MZRL
1.536,50 €
1.645,10 €
1.866,30 €
2.165,10 €
2.405,60 €
2.650,10 €
3.391,20 €
4.233,20 €
5.032,50 €
5.994,70 €
7.030,70 €
8.322,80 €
10.123,10 €
MZRL
1.757,70 €
1.870,20 €
2.176,70 €
2.514,30 €
2.956,60 €
3.204,90 €
3.884,00 €
4.978,10 €
5.765,80 €
7.104,40 €
8.097,70 €
9.727,30 €
11.706,20 €
14.810,20 €
MZGR
2.021,50 €
2.308,60 €
2.875,10 €
3.624,00 €
4.415,50 €
5.540,70 €
6.243,00 €
7.919,20 €
9.261,70 €
12.311,50 €
MZGR
2.432,80 €
2.719,90 €
3.495,90 €
4.303,00 €
5.199,30 €
6.324,50 €
7.178,10 €
8.850,40 €
10.231,70 €
MZGR
2.983,80 €
3.274,80 €
3.984,80 €
5.044,10 €
5.932,60 €
7.434,20 €
8.245,10 €
10.251,10 €
11.814,80 €
15.190,50 €
MZCA
1.090,30 €
1.156,30 €
1.342,50 €
1.524,90 €
1.707,20 €
1.940,00 €
2.234,90 €
2.731,60 €
3.709,30 €
4.318,50 €
5.276,90 €
6.243,00 €
7.884,30 €
9.312,20 €
-
MZCA
1.412,30 €
1.478,30 €
1.676,20 €
1.874,10 €
2.060,30 €
2.351,30 €
2.646,20 €
3.352,40 €
4.388,40 €
5.106,20 €
6.060,70 €
7.178,10 €
8.819,40 €
10.282,20 €
MZCA
1.629,60 €
1.695,60 €
1.905,10 €
2.180,60 €
2.409,50 €
2.902,30 €
3.197,20 €
3.845,10 €
5.129,50 €
5.839,50 €
7.166,50 €
8.245,10 €
10.728,40 €
12.455,00 €
-
UNDER REQUEST
• Fully equipped fans including motor, pulleys,
belts, belts guard and shaft guard. Assembled on
a base plate.
• Flameproof and explosionproof fans with ATEX
certified motors.
• Fans for air working temperatures up to 250ºC,
300ºC or 450ºC.
• Hot-dipped galvanised or stainless steel fans.
NOTE
Fans are supplied as free shaft. For the price of
whole assembled set (motor and transmission execution 9 or 12), please add to the fan cost: motor
and corresponding transmission set size prices.
Prices in accessories section (p.124).
MZZM
1.004,90 €
1.152,40 €
1.272,70 €
1.466,70 €
1.742,20 €
1.924,50 €
2.110,80 €
2.634,60 €
3.348,50 €
4.023,60 €
5.094,50 €
5.684,30 €
7.333,30 €
8.466,30 €
-
MZZM
1.327,00 €
1.474,40 €
1.602,50 €
1.815,90 €
2.200,00 €
2.335,80 €
2.522,00 €
3.251,50 €
4.027,50 €
4.807,40 €
5.882,20 €
6.619,40 €
8.264,60 €
9.436,30 €
MZZM
1.544,30 €
1.691,70 €
1.831,40 €
2.126,30 €
2.440,60 €
2.886,80 €
3.076,90 €
3.744,30 €
4.244,80 €
5.540,70 €
6.984,10 €
7.647,60 €
9.669,10 €
11.023,30 €
-
FAN EXECUTION 1
(FREE SHAFT)
FAN EXECUTION 9
(FREE SHAFT WITH
BACKPACK)
FAN CONFIGURATION 12 (FREE SHAFT
WITH BASEMENT)
CENTRIFUGAL HIGH PRESSURE FANS
AA
Forward cast aluminium impeller
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Fully welded housing.
• AA 47-70: high efficiency single inlet and forward
curved impeller manufactured in cast aluminium.
• AA 45/5-60/7: high efficiency single inlet and
backward curved impeller manufactured in cast aluminium.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and class F insulation. Standard
voltages 230/400V 50Hz, motors up to 4kW and
400/690V 50Hz for higher powers.
AA 47-70
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof ATEX certified motors.
APPLICATIONS
Designed for inline installation, they are suitable for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean air transport.
AA 45/5-60/7
ACCESSORIES
RFS
INT
PE
RA
AC
EI
BA-400
SIL-C
SIL-R
AA 47-70
Code
Model
R.P.M. max.
255140160
255170160
255250160
255280160
255350161
255350160
255430160
255440160
255490160
255500160
255510160
AA 47 T2 0,55kW
AA 47 T2 1,1kW
AA 53 T2 1,1kW
AA 53 T2 2,2kW
AA 59 T2 1,5kW
AA 59 T2 2,2kW
AA 66 T2 2,2kW
AA 66 T2 3kW
AA 70 T2 4kW
AA 70 T2 5,5kW
AA 70 T2 7,5kW
2800
2800
2800
2800
2800
2800
2800
2870
2890
2900
2900
Max. Curr. (A)
230 400 690
2,33
4,42
4,42
8,61
6,01
8,61
8,61
11,1
14,2
-
1,35
2,55
2,55
4,98
3,48
4,98
4,98
6,4
8,2
11
15
6,3
8,6
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,55
1,1
1,1
2,2
1,5
2,2
2,2
3
4
5,5
7,5
450
790
600
1300
550
900
475
790
1000
1500
1700
70
73
72
73
73
74
75
78
80
80
82
41,5
49,5
55,5
67
69
70
82
89
103,5
118,5
125
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
2,2
3
4
5,5
7,5
11
2600
3600
3600
4800
3650
5600
86
90
91
91
95
98
62,5
69,5
79
92
108
141
R.R.P.
€
1.166,00
1.258,10
1.331,60
1.392,10
1.429,20
1.532,60
1.741,50
1.864,40
2.073,90
2.124,30
2.159,00
AA 45/5-60/7
Code
Model
R.P.M. max.
255120106
255120120
255150106
255150120
255520106
255520120
AA 45/5 T2 2,2kW
AA 45/5 T2 3kW
AA 50/5 T2 4kW
AA 50/5 T2 5,5kW
AA 60/7 T2 7,5kW
AA 60/7 T2 11kW
2800
2870
2890
2900
2900
2930
Max. Curr. (A)
230 400 690
8,61
11,1
14,2
-
4,98
6,4
8,2
11
15
19,8
6,3
8,6
11,39
R.R.P.
€
1.357,80
1.521,20
2.017,70
2.340,90
2.794,50
3.051,60
103
CENTRIFUGAL HIGH PRESSURE FANS
AAVA
Backward impeller
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• High efficiency single inlet backward curved impeller, manufactured in rolling steel sheet with epoxy
powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and class F insulation. Manufactured
with standard voltages: 230V 50Hz in single phase
motors, and 230/400V 50Hz in three phase motors
up to 4kW, and 400/690V 50Hz for higher powers.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air 130ºC;
environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof ATEX certified motors.
• Fans for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
APPLICATIONS
Designed for inline installation, they are suitable for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean air transport.
ACCESSORIES
RFS
INT
PE
RA
AC
EI
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Model
AAVA 310/P T2 0,25kW
AAVA 350/P T2 0,37kW
AAVA 400/P T2 0,55kW
AAVA 450/P T2 0,75kW
AAVA 500/P T2 1,1kW
AAVA 560/P T2 1,5kW
AAVA 631/P T2 1,5kW
AAVA 632/P T2 2,2kW
AAVA 711/P T2 3kW
AAVA 712/P T2 4kW
AAVA 801/P T2 4kW
AAVA 802/P T2 5,5kW
AAVA 902/P T2 11kW
104
R.P.M. max.
2800
2800
2800
2800
2800
2800
2800
2800
2870
2890
2890
2900
2930
Max. Curr. (A)
230 400 690
1,17
1,65
2,33
3,03
4,42
6,01
6,01
8,61
11,1
14,2
14,2
-
1,68
0,95
1,35
1,75
2,55
3,48
3,48
4,98
6,4
8,2
8,2
11
19,8
6,3
11,39
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,25
0,37
0,55
0,75
1,1
1,5
1,5
2,2
3
4
4
5,5
11
216
252
288
324
360
396
324
468
468
612
540
612
1080
65
67
69
71
73
75
76
77
79
80
82
84
88
22
24
36
39
42
59
63
66
94
100
111
125
210
R.R.P.
€
890,70
984,30
1.083,00
1.215,80
1.298,50
1.393,70
1.476,80
1.498,50
1.777,90
1.843,00
2.064,60
2.253,80
3.286,90
CENTRIFUGAL HIGH PRESSURE FANS
AAVC
Backward impeller
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Fully welded housing.
• High efficiency single inlet backward curved impeller manufactured in rolling steel sheet and epoxy
powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors up to 4kW, and 400/690V 50Hz for higher
powers.
• Clean air transport.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
• Fans for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
ACCESSORIES
RFS
INT
PE
RA
AC
EI
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Model
R.P.M. max.
AAVC/N 500 T2 1,1kW
AAVC/N 560 T2 1,5kW
AAVC/N 560 T2 2,2kW
AAVC/NR 630 T2 2,2kW
AAVC/NR 630 T2 3kW
AAVC/N 630 T2 3kW
AAVC/N 630 T2 4kW
AAVC/NR 710 T2 4kW
AAVC/NR 710 T2 5,5kW
AAVC/N 710 T2 5,5kW
AAVC/N 710 T2 7,5kW
AAVC/NR 800 T2 7,5kW
AAVC/N 800 T2 11kW
AAVC/NR 900 T2 11kW
AAVC/NR 900 T2 15kW
AAVC/N 900 T2 15kW
AAVC/N 900 T2 18,5kW
AAVC/NR 1000 T2 22kW
AAVC/N 1000 T2 22kW
AAVC/N 1000 T2 30kW
AAVC/NR 1120 T2 45kW
AAVC/N 1120 T2 45kW
AAVC/N 1120 T2 55kW
2800
2800
2800
2800
2870
2870
2890
2890
2900
2900
2900
2900
2930
2930
2930
2930
2935
2940
2940
2950
2960
2960
2965
Max. Curr. (A)
230 400 690
4,42
6,01
8,61
8,61
11,1
11,1
14,2
14,2
-
2,55
3,48
4,98
4,98
6,4
6,4
8,2
8,2
11
11
15
15
19,8
19,8
26,6
26,6
32
39
39
52,6
77,1
77,1
94,2
6,3
6,3
8,6
8,6
11,39
11,39
15,3
15,3
18,4
22,43
22,43
30,25
44,33
44,33
54,17
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,1
1,5
2,2
2,2
3
3
4
4
5,5
5,5
7,5
7,5
11
11
15
15
18,5
22
22
30
45
45
55
648
504
1044
756
1296
864
1476
1152
1872
1296
2376
1476
2376
1476
2628
2160
3024
2628
1872
3420
4716
3744
6120
75
79
79
81
82
83
83
87
87
87
88
88
90
91
91
92
92
93
94
94
95
98
98
63
95
98
125
130
130
134
162
179
185
188
219
256
357
369
369
380
467
467
522
730
730
795
R.R.P.
€
1.939,60
2.398,90
2.420,60
2.713,50
2.791,00
2.791,00
2.856,20
3.366,70
3.555,80
3.555,80
3.611,60
4.403,20
4.719,50
5.621,90
5.663,30
5.663,30
5.815,00
7.957,30
7.957,30
8.426,10
12.135,60
12.135,60
12.735,90
105
CENTRIFUGAL HIGH PRESSURE FANS
AAVP
Backward impeller
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Fully welded housing.
• High efficiency single inlet backward curved impeller manufactured in rolling steel sheet and epoxy
powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors up to 4kW, and 400/690V 50Hz for higher
powers.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
ACCESSORIES
RFS
INT
PE
RA
AC
EI
• Clean and slightly dusty air transport.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air 130ºC;
environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
• Fan for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
• Special motors for frequency regulation (recommended for motor sizes IEC280 and larger).
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Model
R.P.M. max.
AAVP/N 400 T2 1,1kW
AAVP/N 451 T2 1,1kW
AAVP/N 452 T2 1,5kW
AAVP/NR 501 T2 1,1kW
AAVP/NR 502 T2 1,5kW
AAVP/N 501 T2 1,5kW
AAVP/N 502 T2 2,2kW
AAVP/NR 561 T2 1,5kW
AAVP/NR 562 T2 2,2kW
AAVP/NR 563 T2 3kW
AAVP/N 561 T2 2,2kW
AAVP/N 562 T2 3kW
AAVP/N 563 T2 4kW
AAVP/NR 631 T2 3kW
AAVP/NR 632 T2 4kW
AAVP/NR 633 T2 5,5kW
AAVP/N 631 T2 4kW
AAVP/N 632 T2 5,5kW
AAVP/N 633 T2 7,5kW
AAVP/NR 711 T2 7,5kW
AAVP/NR 713 T2 11kW
AAVP/N 712 T2 11kW
AAVP/N 713 T2 15kW
AAVP/NR 801 T2 11kW
AAVP/NR 802 T2 15kW
AAVP/NR 803 T2 18,5kW
AAVP/N 801 T2 15kW
AAVP/N 802 T2 18,5kW
AAVP/N 803 T2 22kW
AAVP/NR 901 T2 18,5kW
AAVP/NR 902 T2 22kW
AAVP/NR 903 T2 30kW
AAVP/N 901 T2 22kW
AAVP/N 902 T2 30kW
AAVP/N 903 T2 37kW
AAVP/NR 1001 T2 37kW
AAVP/NR 1002 T2 45kW
AAVP/NR 1003 T2 55kW
AAVP/N 1001 T2 45kW
AAVP/N 1002 T2 55kW
AAVP/N 1003 T2 75kW
AAVP/NR 1121 T2 55kW
AAVP/NR 1122 T2 75kW
AAVP/NR 1123 T2 90kW
AAVP/N 1121 T2 75kW
AAVP/N 1122 T2 90kW
AAVP/N 1123 T2 110kW
2800
2800
2800
2800
2800
2800
2800
2800
2800
2870
2800
2870
2890
2870
2890
2900
2890
2900
2900
2900
2930
2930
2930
2930
2930
2935
2930
2935
2940
2935
2940
2950
2940
2950
2955
2955
2960
2965
2960
2965
2965
2965
2965
2970
2965
2970
2975
106
Max. Curr. (A)
230
400
690
4,42
4,42
6,01
4,42
6,01
6,01
8,61
6,01
8,61
11,1
8,61
11,1
14,2
11,1
14,2
14,2
-
2,55
2,55
3,48
2,55
3,48
3,48
4,98
3,48
4,98
6,4
4,98
6,4
8,2
6,4
8,2
11
8,2
11
15
15
19,8
19,8
26,6
19,8
26,6
32
26,6
32
39
32
39
52,6
39
52,6
64,3
64,3
77,1
94,2
77,1
94,2
126,6
94,2
126,6
151,7
126,6
151,7
185
6,3
6,3
8,6
8,6
11,39
11,39
15,3
11,39
15,3
18,4
15,3
18,4
22,43
18,4
22,43
30,25
22,43
30,25
36,97
36,97
44,33
54,17
44,33
54,17
72,8
54,17
72,8
87,23
72,8
87,23
106,38
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,1
1,1
1,5
1,1
1,5
1,5
2,2
1,5
2,2
3
2,2
3
4
3
4
5,5
4
5,5
7,5
7,5
11
11
15
11
15
18,5
15
18,5
22
18,5
22
30
22
30
37
37
45
55
45
55
75
55
75
90
75
90
110
792
900
1152
648
1008
792
380
720
1152
1620
900
1296
2160
1008
1620
2628
1152
1836
2988
2340
2988
3780
4716
2628
3780
5328
2988
4212
5328
3348
4212
6768
2988
4716
6768
5328
7560
9468
6048
7560
11988
6768
9468
13320
7560
9468
13320
72
73
74
75
77
77
77
79
79
80
80
81
81
82
82
82
83
87
87
88
89
89
89
90
90
90
90
90
92
91
93
93
94
94
94
95
95
95
95
95
95
97
97
97
99
99
99
48
57
63
62
65
65
67
94
96
102
98
107
111
128
136
147
136
150
155
189
220
196
230
261
267
278
272
283
305
400
422
537
428
543
554
630
674
746
681
753
852
860
999
992
967
959
1158
R.R.P.
€
1.405,30
1.539,90
1.567,80
1.971,30
1.999,20
1.999,20
2.020,90
2.434,50
2.456,30
2.533,80
2.456,30
2.533,80
2.598,90
2.862,30
2.927,40
3.116,50
2.927,40
3.116,50
3.172,30
3.663,10
3.979,40
3.979,40
4.020,80
4.763,10
4.804,50
4.956,20
4.804,50
4.956,20
5.270,00
5.925,80
6.239,60
6.708,40
6.239,60
6.708,40
6.918,00
8.936,40
9.705,50
10.305,90
9.705,50
10.305,90
10.782,60
13.092,10
13.568,90
14.587,80
13.568,90
14.587,80
18.861,00
CENTRIFUGAL HIGH PRESSURE FANS
AAVG/N
Backward impeller
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Fully welded housing.
• High efficiency single inlet backward curved
impeller, manufactured in rolling steel sheet and
epoxy powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors up to 4kW, and 400/690V 50Hz for higher
powers.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean and slightly dusty air transport.
ACCESSORIES
RFS
INT
PE
RA
AC
EI
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
• Fans for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
• Special motors for frequency regulation (recommended for motor sizes IEC280 and larger).
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Model
R.P.M. max.
AAVG/N 350 T2 1,1kW
AAVG/N 400 T2 1,5kW
AAVG/N 450 T2 2,2kW
AAVG/NR 501 T2 3kW
AAVG/NR 502 T2 4kW
AAVG/N 501 T2 4kW
AAVG/N 502 T2 5,5kW
AAVG/NR 561 T2 5,5kW
AAVG/NR 562 T2 7,5kW
AAVG/N 561 T2 7,5kW
AAVG/NR 632 T2 11kW
AAVG/N 631 T2 11kW
AAVG/N 632 T2 15kW
AAVG/NR 711 T2 18,5kW
AAVG/NR 712 T2 22kW
AAVG/N 711 T2 22kW
AAVG/N 712 T2 30kW
AAVG/NR 801 T2 30kW
AAVG/NR 802 T2 37kW
AAVG/N 801 T2 37kW
AAVG/N 802 T2 45kW
AAVG/NR 901 T2 55kW
AAVG/NR 902 T2 75kW
AAVG/N 901 T2 75kW
AAVG/N 902 T2 90kW
AAVG/NR 1001 T2 90kW
AAVG/NR 1002 T2 110kW
AAVG/N 1001 T2 110kW
AAVG/N 1002 T2 132kW
2800
2800
2800
2870
2890
2890
2900
2900
2900
2900
2930
2930
2930
2935
2940
2940
2950
2950
2955
2955
2960
2965
2965
2965
2970
2970
2975
2975
2980
Max. Curr. (A)
230
400
690
4,42
6,01
8,61
11,1
14,2
14,2
-
2,55
3,48
4,98
6,4
8,2
8,2
11
11
15
15
19,8
19,8
26,6
32
39
39
52,6
52,6
64,3
64,3
77,1
94,2
126,6
126,6
151,7
151,7
185
185
219,9
6,3
6,3
8,6
8,6
11,39
11,39
15,3
18,4
22,43
22,43
30,25
30,25
36,97
36,97
44,33
54,17
72,8
72,8
87,23
87,23
106,38
106,38
126,44
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,1
1,5
2,2
3
4
4
5,5
5,5
7,5
7,5
11
11
15
18,5
22
22
30
30
37
37
45
55
75
75
90
90
110
110
132
1044
1296
1836
2124
3024
2376
3384
3384
4680
3600
6084
4140
6804
6804
9504
6804
10800
8460
11880
8460
13428
11880
21600
15228
23760
15228
23760
17028
26640
78
79
80
81
81
82
86
87
87
87
89
89
89
91
93
93
94
95
95
96
96
96
97
97
97
98
98
99
99
33
53
65
87
93
93
107
127
133
135
193
196
198
246
368
272
388
424
435
440
484
701
802
808
840
920
1078
1085
1112
R.R.P.
€
1.322,20
1.520,30
1.811,20
2.153,90
2.219,00
2.219,00
2.408,10
2.720,80
2.776,60
2.776,60
3.532,20
3.532,20
3.573,60
4.449,60
4.763,40
4.763,40
5.232,20
6.969,60
7.179,20
7.179,20
7.948,30
9.652,90
10.129,60
10.129,60
11.148,60
12.913,70
17.186,90
17.186,90
17.399,30
107
CENTRIFUGAL HIGH PRESSURE FANS
AAVM
Backward impeller
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Fully welded housing.
• High efficiency single inlet backward curved
impeller, manufactured in rolling steel sheet and
epoxy powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors up to 4kW, and 400/690V 50Hz for higher
powers.
APPLICATIONS
Designed for inline installation, they are suitable for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
ACCESSORIES
RFS
INT
PE
RA
AC
EI
• Clean and slightly dusty air transport.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
• Fans for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
• Special motors for frequency regulation (recommended for motor sizes IEC280 and larger).
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Max. Curr. (A)
400
690
Model
R.P.M.
max.
230
AAVM/NR 350 T2 0,75kW
AAVM/N 350 T2 1,1kW
AAVM/NR 400 T2 1,5kW
AAVM/N 400 T2 2,2kW
AAVM/NR 450 T2 3kW
AAVM/N 450 T2 4kW
AAVM/NR 500 T2 4kW
AAVM/N 500 T2 5,5kW
AAVM/NR 560 T2 7,5kW
AAVM/N 560 T2 11kW
AAVM/NR 630 T2 15kW
AAVM/N 630 T2 18,5kW
AAVM/NR 711 T2 22kW
AAVM/N 711 T2 30kW
AAVM/NR 801 T2 37kW
AAVM/N 801 T2 55kW
AAVM/NR 901 T2 75kW
AAVM/N 901 T2 90kW
AAVM/NR 1001 T2 110kW
AAVM/N 1001 T2 160kW
2800
2800
2800
2800
2870
2890
2890
2900
2900
2930
2930
2935
2940
2950
2955
2965
2965
2970
2975
2980
3,03
4,42
6,01
8,61
11,1
14,2
14,2
-
108
1,75
2,55
3,48
4,98
6,4
8,2
8,2
11
15
19,8
26,6
32
39
52,6
64,3
94,2
126,6
151,7
185
263,1
6,3
8,6
11,39
15,3
18,4
22,43
30,25
36,97
54,17
72,8
87,23
106,38
151,28
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,75
1,1
1,5
2,2
3
4
4
5,5
7,5
11
15
18,5
22
30
37
55
75
90
110
160
1296
1656
1872
2376
2664
3384
3384
4680
4680
6480
6480
9360
8280
11988
11988
18720
18720
23760
21240
33840
69
70
74
75
76
77
80
84
86
87
88
89
91
92
92
93
93
94
94
95
32
36
48
52
63
78
93
106
133
141
193
206
276
396
436
550
802
841
1085
1115
R.R.P.
€
863,50
879,00
997,90
1.019,60
1.469,20
1.534,30
1.732,20
1.921,30
2.507,40
2.823,80
3.348,00
3.499,80
4.696,10
5.164,90
6.961,50
8.331,00
10.129,60
11.148,60
17.843,90
18.756,10
CENTRIFUGAL HIGH PRESSURE FANS
AA P/R
Straight blade impeller
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Fully welded housing.
• Straight blade impeller manufactured in rolled
steel sheet and epoxy powder finishing coat.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors up to 4kW, and 400/690V 50Hz for higher
powers.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof ATEX certified motors.
• Hot-dipped galvanised or stainless steel fan.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Solid material transport (except for textile fibers).
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
ACCESSORIES
RFS
INT
PE
AC
EI
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Code
Model
R.P.M. max.
255120160
255120161
255150160
255150161
255520161
255520160
AA 45/5 T2 2,2kW P/R
AA 45/5 T2 3kW P/R
AA 50/5 T2 4kW P/R
AA 50/5 T2 5,5kW P/R
AA 60/7 T2 7,5kW P/R
AA 60/7 T2 11kW P/R
2800
2870
2890
2900
2900
2930
Max. Curr. (A)
230
400
690
8,61
11,1
14,2
-
4,98
6,4
8,2
11
15
19,8
6,3
8,6
11,39
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
2,2
3
4
5,5
7,5
11
2900
3100
3100
4000
4500
5000
87
88
91
92
92
93
68
69
119
120
150
177
R.R.P.
€
1.768,60
1.803,30
1.940,20
2.251,50
2.431,60
2.701,40
109
CENTRIFUGAL HIGH PRESSURE FANS
AAZA P/R
Straight blade impeller
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Fully welded housing.
• Straight blade impeller manufactured in rolled
steel sheet and epoxy powder coat finishing.
• Epoxy powder coat finishing.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and class F insulation. Manufactured with standard voltages: 230V 50Hz in single
phase motors and 230/400V 50Hz in three phase
motors up to 4kW, and 400/690V 50Hz for higher
powers.
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
• Flameproof or explosionproof fans with ATEX certified motors.
• Fans for air working temperatures up to 250ºC.
• Hot-dipped galvanised or stainless steel fans.
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Transport of solid material and textile fibers.
• Maximum working temperature: carried air
130ºC; environment: 60ºC.
ACCESSORIES
RFS
INT
PE
AC
EI
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Model
R.P.M. max.
AAZA 400 T2 0,75kW P/R
AAZA 400 T2 1,1kW P/R
AAZA 450 T2 1,1kW P/R
AAZA 450 T2 1,5kW P/R
AAZA 500 T2 2,2kW P/R
AAZA 500 T2 3kW P/R
AAZA 560 T2 3kW P/R
AAZA 560 T2 4kW P/R
AAZA 630 T2 5,5kW P/R
AAZA 630 T2 7,5kW P/R
AAZA 710 T2 7,5kW P/R
AAZA 710 T2 11kW P/R
AAZA 800 T2 11kW P/R
AAZA 800 T2 15kW P/R
AAZA 800 T2 18,5kW P/R
AAZA 800 T4 3kW P/R
AAZA 800 T4 4kW P/R
AAZA 900 T4 5,5kW P/R
AAZA 900 T4 7,5kW P/R
AAZA 1000 T4 11kW P/R
2800
2800
2800
2800
2800
2870
2870
2890
2900
2900
2900
2930
2930
2930
2935
1430
1440
1440
1440
1460
110
Max. Curr. (A)
230
400
690
3,03
4,42
4,42
6,01
8,61
11,1
11,1
14,2
11,7
15,2
-
1,75
2,55
2,55
3,48
4,98
6,4
6,4
8,2
11
15
15
19,8
19,8
26,6
32
6,8
8,8
12
15
20,9
6,3
8,6
8,6
11,39
11,39
15,3
18,4
6,9
8,6
12,02
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,75
1,1
1,1
1,5
2,2
3
3
4
5,5
7,5
7,5
11
11
15
18,5
3
4
5,5
7,5
11
360
792
468
792
1044
1656
900
1476
620
545
1152
2376
1872
2124
2664
2124
2124
3024
3024
4140
79
79
84
84
86
87
89
89
94
94
97
97
98
99
100
79
80
82
83
87
31
32
36
40
58
65
80
85
122
128
148
185
245
248
282
169
178
266
294
457
R.R.P.
€
1.389,90
1.405,30
1.539,90
1.567,80
1.874,50
1.952,00
2.363,60
2.428,70
2.914,70
2.970,50
3.473,10
3.789,50
4.588,90
4.630,30
4.782,10
3.965,60
4.046,20
5.249,70
5.339,20
10.448,10
CENTRIFUGAL HIGH PRESSURE FANS
GROUP
Free shaft without motor or belt driven motor in different configurations
MANUFACTURING FEATURES
• Rolling steel sheet housing, fully welded and protected against corrosion with epoxy powder finishing coat.
• High efficiency single inlet backward curved impeller manufactured in rolling steel sheet protected
against corrosion with epoxy powder finishing coat.
AAZZA P/R range with straight blade turbine in steel
sheet protected with epoxy powder.
• Supplied with free shaft, (i.e. without motor, pulleys nor belts).
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Pneumatic transport.
• Clean air (AAZVA, AAZVC) or slightly dusty air
transport (AAZVP, AAZVG, AAZVM).
Size
AAZZA
350
400
450
500
560
630
710
800
900
1000
1120
2.200,00 €
2.654,00 €
2.964,40 €
3.402,80 €
3.724,90 €
4.780,20 €
5.637,70 €
7.185,90 €
12.684,00 €
-
Size
AAZZA
350
400
450
500
560
630
710
800
900
1000
Size
350
400
450
500
560
630
710
800
900
1000
1120
2.591,90 €
3.065,30 €
3.488,20 €
3.984,80 €
4.306,90 €
5.455,40 €
6.421,50 €
8.113,20 €
13.654,00 €
AAZZA
3.061,40 €
3.515,30 €
4.178,80 €
4.737,60 €
5.203,20 €
6.472,00 €
7.445,90 €
9.234,60 €
14.841,30 €
-
AAZVG/N
AAZVG/P
1.637,40 €
2.037,00 €
2.440,60 €
2.654,00 €
3.740,40 €
4.694,90 €
5.986,90 €
7.698,10 €
10.309,30 €
13.941,10 €
14.651,10 €
AAZVM
3.084,70 €
3.550,30 €
3.868,40 €
4.923,80 €
5.781,30 €
6.786,20 €
7.523,50 €
13.591,90 €
2.110,80 €
2.607,40 €
2.894,50 €
3.173,90 €
4.019,80 €
4.927,70 €
6.060,70 €
7.938,60 €
10.309,30 €
12.788,70 €
-
2.110,80 €
2.607,40 €
2.894,50 €
3.173,90 €
4.019,80 €
4.927,70 €
6.060,70 €
7.938,60 €
10.309,30 €
-
2.207,80 €
2.347,40 €
3.123,50 €
3.596,80 €
3.946,00 €
4.978,10 €
5.824,00 €
7.306,20 €
9.824,30 €
12.831,40 €
AAZVM
AAZVC
AAZVG/N
AAZVG/P
AAZVP
2.460,00 €
2.999,30 €
3.305,80 €
3.701,60 €
4.605,60 €
5.509,70 €
6.735,80 €
8.718,50 €
11.240,60 €
13.758,70 €
2.460,00 €
2.999,30 €
3.305,80 €
3.701,60 €
4.605,60 €
5.509,70 €
6.735,80 €
8.718,50 €
11.240,60 €
-
AAZVG/N
AAZVG/P
2.929,50 €
3.468,80 €
3.755,90 €
4.392,20 €
5.350,60 €
6.406,00 €
7.752,40 €
9.746,70 €
12.361,90 €
14.946,00 €
-
2.929,50 €
3.468,80 €
3.755,90 €
4.392,20 €
5.350,60 €
6.406,00 €
7.752,40 €
9.746,70 €
12.361,90 €
-
1.982,70 €
2.428,90 €
2.848,00 €
3.177,80 €
4.326,30 €
5.276,90 €
6.662,10 €
8.481,80 €
11.240,60 €
14.907,20 €
AAZVM
2.456,10 €
2.898,40 €
3.301,90 €
3.868,40 €
5.075,10 €
6.173,20 €
7.678,70 €
9.506,20 €
12.361,90 €
16.094,50 €
16.847,30 €
AAZVC
3.612,30 €
4.132,30 €
4.454,30 €
5.602,80 €
6.565,10 €
7.717,50 €
11.283,20 €
AAZVC
4.299,10 €
4.881,10 €
5.350,60 €
6.619,40 €
7.593,30 €
8.838,80 €
12.466,70 €
15.784,10 €
• Transport of solid material and textile fibers (AZZA
P/R).
UNDER REQUEST
• Fully equipped fans including motor,
pulleys, belts, belts guard and shaft guard.
Assembled on a base plate.
• Flameproof and explosionproof fans with
ATEX certified motors.
• Fans for air working temperatures up to
250ºC, 300ºC or 450ºC.
• Hot-dipped galvanised or stainless steel fans.
NOTE
Fans are supplied as free shaft. For the price of
whole assembled set (motor and transmission execution 9 or 12), please add to the fan cost: motor
and corresponding transmission set size prices.
Prices in accessories section (p.124).
AAZVP
2.595,80 €
2.758,70 €
3.647,30 €
4.178,80 €
4.528,00 €
5.657,10 €
6.611,60 €
8.241,30 €
10.798,20 €
AAZVP
3.065,30 €
3.170,00 €
4.337,90 €
4.923,80 €
5.424,30 €
6.669,80 €
7.632,10 €
9.354,90 €
11.977,80 €
15.023,60 €
AZZVA
1.695,60 €
1.951,70 €
1.951,70 €
1.951,70 €
2.250,40 €
2.250,40 €
2.778,10 €
3.007,10 €
4.105,10 €
-
AZZVA
2.157,30 €
2.343,60 €
2.363,00 €
2.479,40 €
2.832,50 €
2.832,50 €
3.453,30 €
3.794,70 €
5.036,30 €
-
AZZVA
2.510,40 €
2.813,10 €
2.813,10 €
3.166,10 €
3.581,30 €
3.728,70 €
4.466,00 €
4.819,00 €
6.157,70 €
-
FAN EXECUTION 1
(FREE SHAFT)
FAN EXECUTION 9
(FREE SHAFT WITH
BACKPACK)
FAN CONFIGURATION 12 (FREE SHAFT
WITH BASEMENT)
111
ATEX FANS
ATEX FANS
www.casals.tv
112
ATEX FANS
HBX
Wall plate axial
MANUFACTURING FEATURES
• Plate axial fan, circular reinforced frame.
• Motor-impeller assembly through a modular system.
• Cast aluminium impeller.
• Epoxy powder coat finishing.
• ATEX standard asynchronous motor. Standard voltages 230V 50Hz for single phase motors,
230/400V 50Hz for three phase, motors up to 5,5
HP and 400/690V 50Hz for higher powers.
APPLICATIONS
Designed for wall or duct installation, they are suitable for:
• General ventilation in closed environments classified as ATEX zone 1 or 2.
• Maximum working temperature: 50ºC.
ACCESSORIES
RFS
INT
PE
RP0
RP1
PC
UNDER REQUEST
• B form impeller (air flow from impeller to motor),
100% reversible impeller.
• 60Hz fans and special voltages.
• Fan sizes bigger than 100.
In compliance with the 94/9/CE Directive. ATEX
II2G certified.
For areas 1(gas), 2(gas) or 22(dust). Protection level
according to the needs.
Notified organism: IMQ (under No. 0051)
Identification No.: 43EJ00001
PCP
MC HB
THREE PHASE RANGE
Model
HBX 30 T2 0,25kW
HBX 30 T4 0,12kW
HBX 35 T2 0,37kW
HBX 35 T4 0,12kW
HBX 40 T2 1,1kW
HBX 40 T4 0,25kW
HBX 45 T2 1,5kW
HBX 45 T2 2,2kW
HBX 45 T4 0,37kW
HBX 45 T6 0,12kW
HBX 50 T4 0,55kW
HBX 50 T6 0,25kW
HBX 56 T4 0,55kW
HBX 56 T4 0,75kW
HBX 56 T4 1,1kW
HBX 56 T4 1,5kW
HBX 56 T6 0,25kW
HBX 56 T6 0,37kW
HBX 56 T6 0,55kW
HBX 63 T4 0,75kW
HBX 63 T4 1,1kW
HBX 63 T4 1,5kW
HBX 63 T4 2,2kW
HBX 63 T4 3kW
HBX 63 T6 0,37kW
HBX 63 T6 0,55kW
HBX 63 T6 0,75kW
HBX 71 T4 1,1kW
HBX 71 T4 1,5kW
HBX 71 T4 2,2kW
HBX 71 T4 3kW
HBX 71 T6 0,55kW
HBX 71 T6 0,75kW
HBX 71 T6 1,1kW
R.P.M. max.
2800
1400
2800
1400
2800
1400
2800
2800
1400
850
1400
900
1400
1400
1400
1400
900
900
900
1400
1400
1400
1430
1430
900
900
910
1400
1400
1430
1430
900
910
910
230
1,17
0,84
1,65
0,84
4,42
1,44
6,01
8,61
1,94
1,08
2,69
1,51
2,69
3,48
4,74
6,31
1,51
2,13
2,85
3,48
4,74
6,31
8,06
11,7
2,13
2,85
4
4,74
6,31
8,06
11,7
2,85
4
5,5
Max. Curr. (A)
400
690
1,68
0,48
0,95
0,48
2,55
0,83
3,48
4,98
1,12
0,62
1,56
0,87
1,56
2,01
2,75
3,65
0,87
1,23
1,65
2,01
2,75
3,65
5
6,8
1,23
1,65
2,3
2,75
3,65
5
6,8
1,65
2,3
3,2
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
0,25
0,18
0,37
0,11
1,1
0,25
1,5
2,2
0,37
0,12
0,55
0,25
0,55
0,75
1,1
1,5
0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
0,37
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
3100
1550
5200
2900
8500
4700
12100
13500
7500
5200
10065
6000
11330
12650
13970
15600
8680
9500
10170
14080
16500
18620
21010
23430
11440
12430
13860
20570
22000
23870
27060
15400
17480
19640
70
57
77
60
84
64
85
87
67
54
67
55
70
71
72
73
59
59
60
60
70
71
72
73
60
61
62
75
76
77
78
63
64
65
R.R.P. €
II2G EE(x-e)
759,10
708,10
817,20
783,10
1.145,40
915,30
1.173,50
1.271,60
935,00
1.013,50
807,20
803,00
825,90
1.003,60
1.058,50
1.090,20
957,80
821,70
1.021,60
1.247,60
1.302,50
1.334,30
1.498,30
1.726,50
1.065,70
1.265,60
1.261,30
1.384,70
1.416,40
1.580,40
1.808,60
1.347,60
1.343,40
1.498,70
R.R.P. €
II2G EE(x-d)
1.003,80
1.034,30
1.521,10
1.167,60
1.523,70
1.351,70
1.426,80
1.862,30
1.347,10
1.197,00
1.428,30
1.227,10
1.452,00
1.573,00
1.665,40
1.827,40
1.206,30
1.250,90
1.297,70
1.524,80
1.755,60
1.917,70
2.292,90
2.550,70
1.374,80
1.546,80
1.836,70
1.861,70
2.023,70
2.399,00
2.656,80
1.647,00
1.662,90
1.826,90
113
ATEX FANS
Model
HBX 80 T4 2,2kW
HBX 80 T4 3kW
HBX 80 T4 4kW
HBX 80 T6 0,75kW
HBX 80 T6 1,1kW
HBX 80 T6 1,5kW
HBX 80 T6 2,2kW
HBX 90 T4 3kW
HBX 90 T4 4kW
HBX 90 T4 5,5kW
HBX 90 T4 7,5kW
HBX 90 T6 1,5kW
HBX 90 T6 2,2kW
HBX 90 T6 3kW
HBX 100 T4 5,5kW
HBX 100 T4 7,5kW
HBX 100 T4 11kW
HBX 100 T4 15kW
HBX 100 T6 2,2kW
HBX 100 T6 3kW
HBX 100 T6 4kW
R.P.M. max.
1430
1430
1440
910
910
940
940
1430
1440
1440
1440
940
940
960
1440
1440
1460
1460
940
960
960
BOX HBX
230
Max. Curr. (A)
400
690
8,06
11,7
15,2
4
5,5
6,9
9,7
11,7
15,2
6,9
9,7
12,4
9,7
12,4
16,3
5
6,8
8,8
2,3
3,2
4
5,6
6,8
8,8
12
15
4
5,6
7,2
12
15
20,9
27,9
5,6
7,2
9,4
6,9
8,6
6,9
8,6
12,02
16,04
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
2,2
3
4
0,75
1,1
1,5
2,2
3
4
5,5
7,5
1,5
2,2
3
5,5
7,5
11
15
2,2
3
4
29700
34980
38700
23100
25840
28600
30620
37540
44320
49370
55040
30580
35390
39910
53080
61590
66450
71510
37740
45690
51450
80
81
82
67
70
71
72
84
85
87
88
75
76
77
89
89
90
91
79
80
81
APPLICATIONS
Designed for wall or duct installation, they are suitable for:
• Air renewal in buildings and industries.
114
R.R.P. €
II2G EE(x-d)
1.555,00
1.783,20
2.107,60
1.318,00
1.473,40
1.712,50
1.993,90
1.822,00
2.045,40
2.141,20
2.568,50
1.751,30
2.072,70
2.267,70
2.415,00
2.742,50
3.539,10
4.547,60
2.246,60
2.541,70
2.826,90
2.566,10
2.823,80
2.887,00
1.994,00
2.110,00
2.547,10
2.610,20
2.904,00
2.967,00
3.618,60
3.632,40
2.690,40
2.896,40
3.267,10
3.795,30
3.809,00
5.018,70
5.719,50
3.073,20
3.443,60
3.628,90
Inline soundproof cabinet axial
MANUFACTURING FEATURES
• BOX: Galvanised steel soundproof box with Flexiroll Pol Na 30 anthracite grey M1 fire resistance.
Easy motor access and fan maintenance through
removable panels.
• HBX: internal axial fan, circular reinforced frame.
Modular motor-impeller assembly. Polyamide impeller with variable pitch angle reinforced with fiberglass. Sparkproof aluminium hoop. Epoxy powder finishing coat.
• Motor-impeller assembly through modular system. Variable pitch angle polyamide impeller reinforced with fiberglass. Epoxy powder coat finishing.
• Squirrel cage asynchronous standard motor, IP55 protection and rated class F insulation. Standard voltages 230V 50Hz for single phase motors,
230/400V 50Hz for three phase, motors up to 4kW
and 400/690V 50Hz for higher powers.
ACCESSORIES
R.R.P. €
II2G EE(x-e)
RFS
INT
PE
JE 45
• Smoke extraction.
• Maximum working temperature: 50ºC.
UNDER REQUEST
• 100% reversible impeller.
• 60Hz fans and special voltages.
• Fan sizes bigger than 100.
• ATEX models BOX HBX: General ventilation in
closed environments classified as ATEX zone 1 or 2.
In compliance with the 94/9/CE Directive. With
ATEX II2G, II3G marking and certificate.
For areas 1(gas), 2(gas) or 22(dust). Protection level
according to the needs.
Notified organism: IMQ (under No. 0051)
Identification No.: 43EJ00001
ATEX FANS
THREE PHASE RANGE
Model
BOX HBX 40 T4 1/3
BOX HBX 45 T2 2
BOX HBX 45 T2 3
BOX HBX 45 T4 1/2
BOX HBX 45 T6 1/3
BOX HBX 50 T4 3/4
BOX HBX 50 T6 1/3
BOX HBX 56 T4 3/4
BOX HBX 56 T4 1
BOX HBX 56 T4 1,5
BOX HBX 56 T4 2
BOX HBX 56 T6 1/3
BOX HBX 56 T6 1/2
BOX HBX 56 T6 3/4
BOX HBX 63 T4 1
BOX HBX 63 T4 1,5
BOX HBX 63 T4 2
BOX HBX 63 T4 3
BOX HBX 63 T4 4
BOX HBX 63 T6 1/2
BOX HBX 63 T6 3/4
BOX HBX 63 T6 1
BOX HBX 71 T4 1,5
BOX HBX 71 T4 2
BOX HBX 71 T4 3
BOX HBX 71 T4 4
BOX HBX 71 T6 3/4
BOX HBX 71 T6 1
BOX HBX 71 T6 1,5
BOX HBX 80 T4 3
BOX HBX 80 T4 4
BOX HBX 80 T4 5,5
BOX HBX 80 T6 1
BOX HBX 80 T6 1,5
BOX HBX 80 T6 2
BOX HBX 80 T6 3
BOX HBX 90 T4 4
BOX HBX 90 T4 5,5
BOX HBX 90T4 7,5
BOX HBX 90 T4 10
BOX HBX 90 T6 2
BOX HBX 90 T6 3
BOX HBX 90 T6 4
BOX HBX 100 T4 7,5
BOX HBX 100 T4 10
BOX HBX 100 T4 15
BOX HBX 100 T4 20
BOX HBX 100 T6 3
BOX HBX 100 T6 4
BOX HBX 100 T6 5,5
R.P.M.
max.
1450
2860
2860
1360
880
1410
940
1410
1400
1400
1420
880
940
900
1400
1400
1420
1390
1400
900
900
910
1400
1420
1390
1400
900
910
920
1390
1400
1440
910
920
940
950
1400
1440
1440
1450
940
950
950
1440
1450
1450
1455
950
950
950
Max. Curr. (A)
230
400
690
1,4
6,25
8,28
1,82
1,89
2,46
2,23
2,46
3,67
4,66
6,46
1,89
2,23
3,46
3,67
4,66
6,46
8,83
11,78
2,23
3,46
4,21
4,66
6,46
8,83
11,78
3,46
4,21
5,07
8,83
11,78
15,42
4,21
5,07
7,31
9,53
11,78
15,42
7,31
9,53
12,33
9,53
12,33
16,11
0,81
3,61
4,78
1,05
1,09
1,42
1,29
1,42
2,12
2,69
3,73
1,09
1,29
2
2,12
2,69
3,73
5,1
6,8
1,29
2
2,43
2,69
3,73
5,1
6,8
2
2,43
2,93
5,1
6,8
8,9
2,43
2,93
4,22
5,5
6,8
8,9
11,8
17
4,22
5,5
7,12
11,8
17
24
33
5,5
7,12
9,3
6,81
9,81
6,81
9,81
13,9
19,1
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,25
1,5
2,2
0,37
0,25
0,55
0,25
0,55
0,75
1,1
1,5
0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
0,37
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
2,2
3
4
0,75
1,1
1,5
2,2
3
4
5,5
7,5
1,5
2,2
3
5,5
7,5
11
15
2,2
3
4
4700
12100
13500
7500
5200
10065
6000
11330
12650
13970
15600
8680
9500
10170
14080
16500
18620
21010
23430
11440
12430
13860
20570
22000
23870
27060
15400
17480
19640
29700
34980
38700
23100
25840
28600
30620
37540
44320
49370
55040
30580
35390
39910
53080
61590
66450
71510
37740
45690
51450
61
85
87
67
54
67
55
70
71
72
73
59
59
60
60
70
71
72
73
59
59
60
60
70
71
72
73
60
61
62
75
76
77
78
63
72
84
85
87
88
75
76
77
89
89
90
91
79
80
81
59
67
68
44
50
55
57
58
62
64
54
57
58
62
66
68
77
79
61
62
66
82
84
94
96
78
82
84
102
104
109
90
92
102
105
127
132
148
159
125
128
144
156
167
191
208
136
152
157
307
R.R.P. €
II2G EE(x-e)
1.334,60
1.355,40
1.702,10
1.079,90
1.194,60
1.085,80
1.222,00
1.204,70
1.243,70
1.331,60
1.411,80
1.297,20
1.341,10
1.409,40
1.441,00
1.504,50
1.541,20
1.782,40
2.232,30
1.443,30
1.511,60
1.687,30
1.710,50
1.790,70
2.058,90
2.473,60
1.788,30
1.963,80
2.117,40
2.248,30
2.608,20
2.662,90
2.153,10
2.306,80
2.540,80
2.875,10
3.066,20
3.388,30
3.433,50
3.849,20
2.944,30
3.278,40
3.566,40
4.300,60
4.818,90
5.603,40
7.155,90
4.177,20
4.500,70
4.713,30
R.R.P. €
II2G EE(x-d)
1.927,40
1.948,20
2.441,80
1.858,00
1.688,00
1.950,00
1.721,90
2.069,10
2.156,40
2.310,80
2.494,30
1.790,60
1.841,00
1.894,20
1.967,20
2.413,00
2.596,60
3.021,70
3.313,90
1.918,90
1.996,40
2.504,90
2.689,50
2.873,10
3.298,40
3.590,40
2.272,90
2.464,20
2.650,00
3.487,60
3.779,70
3.851,20
2.970,80
3.186,70
3.537,70
3.581,30
4.183,10
4.254,70
4.604,80
4.992,90
3.941,00
4.174,60
4.594,50
5.460,70
5.849,10
6.835,60
7.632,20
4.624,40
5.045,70
5.256,00
115
ATEX FANS
HMX
Long cased axial
MANUFACTURING FEATURES
• Reinforced fan casing manufactured in rolling
steel sheet.
• Motor-impeller modular assembly for complete
versatility.
• Epoxy powder finishing coat.
• Cast aluminium impeller with variable pitch angle.
• Standard asynchronous ATEX motor. Manufactured with standard voltages: 230/400V 50Hz
in three phase motors up to 4kW, and 400/690V
50Hz for higher powers.
UNDER REQUEST
• 100% reversible impeller. 5% additional cost.
• 60Hz fans and special voltages.
• Fan sizes bigger than 100.
In compliance with the 94/9/CE Directive. ATEX
II2G Certified.
For areas 1(gas), 2(gas) or 22(dust). Protection level
according to the needs.
Notified organism: IMQ (under No. 0051)
Identification No.: 43EJ00001
APPLICATIONS
Designed for wall or duct installation, they are suitable for:
• General ventilation in closed environments classified as ATEX zone 1 or 2.
• Maximum working temperature: 50ºC.
ACCESSORIES
RFS
INT
PE
RP
THREE PHASE RANGE
Model
R.P.M.
max.
HMX 35 T2 0,37kW
HMX 35 T4 0,12kW
HMX 40 T2 1,1kW
HMX 40 T4 0,25kW
HMX 45 T2 1,5kW
HMX 45 T2 2,2kW
HMX 45 T4 0,37kW
HMX 45 T6 0,12kW
HMX 50 T4 0,55kW
HMX 50 T6 0,25kW
HMX 56 T4 0,55kW
HMX 56 T4 0,75kW
HMX 56 T4 1,1kW
HMX 56 T4 1,5kW
HMX 56 T6 0,25kW
HMX 56 T6 0,37kW
HMX 56 T6 0,55kW
HMX 63 T4 0,75kW
HMX 63 T4 1,1kW
HMX 63 T4 1,5kW
HMX 63 T4 2,2kW
HMX 63 T4 3kW
HMX 63 T6 0,37kW
HMX 63 T6 0,55kW
HMX 63 T6 0,75kW
HMX 71 T4 1,1kW
HMX 71 T4 1,5kW
HMX 71 T4 2,2kW
HMX 71 T4 3kW
HMX 71 T6 0,55kW
HMX 71 T6 0,75kW
HMX 71 T6 1,1kW
HMX 80 T4 2,2kW
HMX 80 T4 3kW
HMX 80 T4 4kW
HMX 80 T6 0,75kW
HMX 80 T6 1,1kW
2800
1400
2800
1400
2800
2800
1400
850
1400
900
1400
1400
1400
1400
900
900
900
1400
1400
1400
1430
1430
900
900
910
1400
1400
1430
1430
900
910
910
1430
1430
1440
910
910
116
Max. Curr. (A)
230
400
690
1,65
0,84
4,42
1,44
6,01
8,61
1,94
1,08
2,69
1,51
2,69
3,48
4,74
6,31
1,51
2,13
2,85
3,48
4,74
6,31
8,06
11,7
2,13
2,85
4
4,74
6,31
8,06
11,7
2,85
4
5,5
8,06
11,7
15,2
4
5,5
0,95
0,48
2,55
0,83
3,48
4,98
1,12
0,62
1,56
0,87
1,56
2,01
2,75
3,65
0,87
1,23
1,65
2,01
2,75
3,65
5
6,8
1,23
1,65
2,3
2,75
3,65
5
6,8
1,65
2,3
3,2
5
6,8
8,8
2,3
3,2
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,37
0,12
1,1
0,25
1,5
2,2
0,37
0,12
0,55
0,25
0,55
0,75
1,1
1,5
0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
0,37
0,55
0,75
1,1
1,5
2,2
3
0,55
0,75
1,1
2,2
3
4
0,75
1,1
5200
2900
8500
4700
12100
13500
7500
5200
10065
6000
11330
12650
13970
15600
8680
9500
10170
14080
16500
18620
21010
23430
11440
12430
13860
20570
22000
23870
27060
15400
17480
19640
29700
34980
38700
23100
25840
77
60
84
64
86
88
67
54
69
55
73
74
75
76
62
62
63
72
73
74
75
76
63
64
65
78
79
80
81
66
67
68
83
84
85
70
73
13
12
22
25
23
24
21
22
26
28
29
30
34
36
26
28
30
38
42
44
55
57
36
38
45
46
49
64
66
42
49
49
69
71
76
60
62
R.R.P. €
II2G EE(x-e)
827,60
793,50
1.166,00
935,60
1.232,20
1.517,40
981,70
1.064,20
934,40
1.073,70
960,20
1.053,80
1.111,40
1.171,90
1.054,70
1.099,50
1.169,40
1.310,00
1.367,70
1.401,10
1.605,40
2.029,40
1.258,80
1.328,80
1.508,20
1.453,90
1.487,20
1.681,50
2.105,30
1.415,00
1.584,10
1.741,30
1.932,20
2.356,00
2.457,00
1.834,90
1.992,00
R.R.P. €
II2G EE(x-d)
1.531,50
1.178,10
1.555,10
1.366,20
1.577,90
2.027,90
1.495,60
1.340,70
1.621,40
1.413,50
1.644,30
1.758,40
1.864,80
2.032,30
1.390,50
1.436,40
1.484,90
1.601,10
2.006,80
2.174,20
2.561,90
2.828,30
2.384,90
1.627,00
2.090,60
2.074,60
2.241,90
2.629,60
2.896,00
1.729,40
1.869,10
2.038,60
2.853,30
3.119,70
3.184,90
2.382,10
2.262,30
ATEX FANS
Model
R.P.M.
max.
HMX 80 T6 1,5kW
HMX 80 T6 2,2kW
HMX 90 T4 3kW
HMX 90 T4 4kW
HMX 90 T4 5,5kW
HMX 90 T4 7,5kW
HMX 90 T6 1,5kW
HMX 90 T6 2,2kW
HMX 90 T6 3kW
HMX 100 T4 5,5kW
HMX 100 T4 7,5kW
HMX 100 T4 11kW
HMX 100 T4 15kW
HMX 100 T6 2,2kW
HMX 100 T6 3kW
HMX 100 T6 4kW
940
940
1430
1440
1440
1440
940
940
960
1440
1440
1460
1460
940
960
960
MAX
Max. Curr. (A)
230
400
690
6,9
9,7
11,7
15,2
6,9
9,7
12,4
9,7
12,4
16,3
4
5,6
6,8
8,8
12
15
4
5,6
7,2
12
15
20,9
27,9
5,6
7,2
9,4
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
1,5
2,2
3
4
5,5
7,5
1,5
2,2
3
5,5
7,5
11
15
2,2
3
4
28600
30620
37540
44320
49370
55040
30580
35390
39910
53080
61590
66450
71510
37740
45690
51450
74
75
87
88
90
91
78
79
80
92
92
93
94
82
83
84
68
73
88
93
108
119
85
90
113
121
132
156
171
102
126
134
6,9
8,6
6,9
8,6
12,02
16,04
-
R.R.P. €
II2G EE(x-e)
2.231,30
2.573,00
2.565,70
2.894,70
2.995,70
3.366,00
2.441,00
2.782,60
3.076,80
3.909,70
4.380,90
5.094,00
6.505,40
3.797,50
4.091,60
4.284,80
R.R.P. €
II2G EE(x-d)
2.898,90
2.833,70
3.306,60
3.371,80
4.059,20
4.145,90
3.085,90
3.298,90
3.681,80
4.964,30
5.354,10
6.214,20
6.938,40
4.204,00
4.586,90
4.778,20
Medium pressure centrifugal
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Cast aluminium impeller.
• Epoxy powder finishing coat.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation and ATEX certified EEx-d. Manufactured with standard voltages:
230V 50Hz in single phase motors and 230/400V
50Hz in three phase motors.
APPLICATIONS
Designed for inline installation, they are suitable for:
• Industrial applications, air extraction or injection.
• Cooling of machines and parts.
• Clean and slightly dusty air transport.
• Maximum working temperature: carried air 130ºC;
environment: 60ºC.
ACCESSORIES
RFS
INT
PE
RA
AC
UNDER REQUEST
• 60Hz fans and special voltages.
• 2 speed motors.
In compliance with the 94/9/CE Directive. ATEX
II2G built. Certified II3G with certified ATEX EEx-d
II2G motor for areas 2 (gas) or 22 (dust).
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Model
R.P.M.
máx.
MAX 26 T2 0,37kW
MAX 27 T2 0,55kW
MAX 28 T2 1,1kW
MAX 31 T2 1,5kW
2800
2800
2800
2800
Max. Curr. (A)
230 400 690
1,65
2,33
4,42
6,01
0,95
1,35
2,55
3,48
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,37
0,55
1,1
1,5
870
1100
2150
2550
71
80
80
83
13
14
20
27
R.R.P.
€
994,40
1.081,10
1.320,30
1.450,80
117
ATEX FANS
MBX
Medium pressure centrifugal
MANUFACTURING FEATURES
• Rolling steel sheet housing.
• Completely joined or welded housing.
• Single inlet forward curved impeller made of aluminium sheet.
• Epoxy powder finishing coat.
• Inlet sparkproof ring made of copper or aluminium.
• Standard asynchronous squirrel-cage motor with
IP-55 protection and Class F insulation. ATEX certified EEx-d. Manufactured with standard voltages:
230V 50Hz in single phase motors and 230/400V
50Hz in three phase motors up to 4kW, and
400/690V 50Hz for higher powers.
MBX 12/5 - 20/8
MBX 22/9 - 28/11
UNDER REQUEST
• 60Hz fans and special voltages.
• Special ATEX executions.
In compliance with the 94/9/CE Directive. ATEX
II2G built. Certified II3G with certified ATEX EEx-d
II2G motor for areas 2 (gas) or 22 (dust).
APPLICATIONS
Designed for inline installation, they are suitable
for:
• General ventilation in closed environments classified as ATEX zone 2 or 22.
• Maximum air working temperature from -20ºC
to 80ºC.
MBX 31/12 - 45/18
ACCESSORIES
RFS
INT
PE
RA
EI
AC
BA-400
SIL-C
SIL-R
THREE PHASE RANGE
Model
R.P.M. max.
MBX 16/6 T2 0,37kW
MBX 16/6 T4 0,18kW
MBX 18/7 T2 0,75kW
MBX 18/7 T4 0,25kW
MBX 20/6 T2 0,37kW
MBX 20/8 T2 1,1kW
MBX 20/8 T4 0,37kW
MBX 22/9 T2 1,1kW
MBX 22/9 T2 2,2kW
MBX 22/9 T4 0,55kW
MBX 25/10 T2 2,2kW
MBX 25/10 T2 3kW
MBX 25/10 T4 1,1kW
MBX 28/11 T2 4kW
MBX 28/11 T4 2,2kW
MBX 28/11 T6 0,75kW
MBX 31/12 T4 3kW
MBX 31/12 T4 4kW
MBX 35/14 T4 3kW
MBX 35/14 T4 5,5kW
MBX 40/16 T4 5,5kW
MBX 40/16 T4 7,5kW
MBX 40/16 T6 2,2kW
MBX 45/18 T4 5,5kW
MBX 45/18 T4 7,5kW
MBX 45/18 T4 11kW
MBX 45/18 T6 2,2kW
2800
1400
2800
1400
2800
2800
1400
2800
2800
1400
2800
2870
1400
2890
1430
910
1430
1440
1430
1440
1440
1440
940
1440
1440
1460
940
118
Max. Curr. (A)
230
400
690
1,65
1,12
3,03
1,44
1,65
4,42
1,94
4,42
8,61
2,69
8,61
11,1
4,74
14,2
8,06
4
11,7
15,2
11,7
9,7
9,7
0,95
0,65
1,75
0,83
0,95
2,55
1,12
2,55
4,98
1,56
4,98
6,4
2,75
8,2
5
2,3
6,8
8,8
6,8
12
12
15
5,6
12
15
20,9
5,6
6,9
6,9
8,6
6,9
8,6
12,02
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,37
0,18
0,75
0,25
0,37
1,1
0,37
1,1
2,2
0,55
2,2
3
1,1
4
2,2
0,75
3
4
3
5,5
5,5
7,5
2,2
5,5
7,5
11
2,2
1400
1100
1900
1200
880
2100
2200
1800
3000
2700
2600
3200
3500
4000
5000
3600
5700
6800
6000
9000
9000
11000
7000
8000
11000
18000
9000
70
57
68
63
68
68
60
70
74
60
77
78
64
81
68
58
72
73
78
79
78
79
71
80
82
86
76
9,5
9,5
15
10
14
19
15
24
30
22
32
38
33
46
44
37
57
59
63
76
101
110
94
116
119
190
112
R.R.P. EEx-d
€
886,50
814,90
1.009,20
933,30
1.077,10
962,70
944,30
1.410,90
1.556,30
1.116,40
1.614,10
1.904,90
1.306,40
2.360,10
1.645,40
1.612,60
2.010,60
2.439,60
2.145,80
2.795,20
2.926,90
3.269,40
2.879,80
3.274,70
3.616,20
5.062,30
2.814,40
ATEX FANS
MBPX
Medium pressure backward centrifugal, anticorrosion
MANUFACTURING FEATURES
• Antistatic PE-el housing.
• Backward curved impeller in PP plastic.
• Motor support made of rolled steel sheet with
epoxy powder finishing coat.
• Stainless steel nuts and bolts.
• Standard asynchronous squirrel-cage motor, IP55, class F insulation. Standard voltages 230/400V
50Hz. Equipped with II2G Eex-d motor.
UNDER REQUEST
• 60Hz fans and special voltages fans.
• Stainless steel motor support.
In compliance with the 94/9/CE Directive. ATEX
II2G built. Certified II3G with certified ATEX EEx-d
II2G motor for areas 2 (gas) or 22 (dust).
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Corrosive air transport.
• Chemical and petrochemical industry.
• General ventilation in closed environments classified as ATEX zone 2.
• Laboratories and gas cabinets.
• Maximum working temperature: 50ºC.
ACCESSORIES
RFS
INT
THREE PHASE RANGE
Model
MBPX 20 T2 0,18kW
MBPX 20 T4 0,12kW
MBPX 25 T2 0,37kW
MBPX 25 T4 0,12kW
MBPX 31 T2 1,5kW
MBPX 31 T4 0,25kW
MBPX 31 T6 0,18kW
MBPX 35 T2 2,2kW
MBPX 35 T4 0,37kW
MBPX 35 T6 0,18kW
MBPX 40 T4 0,55kW
MBPX 40 T6 0,25kW
MBPX 45 T2 4kW
MBPX 45 T4 1,1kW
MBPX 45 T6 0,37kW
R.P.M. max.
2800
1400
2800
1400
2800
1400
880
2800
1400
880
1400
900
2890
1400
900
Max. Curr. (A)
230
400
0,91
0,84
1,65
0,84
6,01
1,44
1,22
8,61
1,94
1,22
2,69
1,51
14,2
4,74
2,13
0,53
0,48
0,95
0,48
3,48
0,83
0,7
4,98
1,12
0,7
1,56
0,87
8,2
2,75
1,23
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,18
0,12
0,37
0,12
1,5
0,25
0,18
2,2
0,37
0,18
0,55
0,25
4
1,1
0,37
1100
570
2150
1100
4700
2395
1570
6700
3400
2230
4850
3180
12000
6400
4200
63
47
68
53
76
61
50
76
60
54
68
56
82
64
56
9
9
13
10
26
19
19
32
23
23
33
30
52
41
37
R.R.P.
€
1.360,10
1.318,90
1.821,70
1.537,50
2.709,80
1.911,80
1.926,10
3.113,20
2.190,80
2.109,70
2.876,10
2.817,40
4.811,00
3.497,50
3.193,60
119
ATEX FANS
MBPCX
Medium pressure centrifugal, anticorrosion
MANUFACTURING FEATURES
• Antistatic PE-el housing.
• Forward curved impeller in PP plastic.
• Motor support made of rolled steel sheet with
epoxy powder finishing coat.
• Stainless steel nuts and bolts.
• Standard asynchronous squirrel-cage motor, IP55, class F insulation. Standard voltages 230/400V
50Hz. Equipped with II2G Eex-d motors
UNDER REQUEST
• 60Hz fans and special voltages fans.
• Stainless steel motor support.
In compliance with the 94/9/CE Directive. ATEX
II2G built. Certified II3G with certified ATEX EEx-d
II2G motor for areas 2 (gas) or 22 (dust).
APPLICATIONS
Designed for inline installation, they are suitable
for:
• Corrosive air transport.
• Chemical and petrochemical industry.
• Laboratories and gas cabinets.
• General ventilation in closed environments classified as ATEX zone 2.
• Maximum working temperature: 50ºC.
ACCESSORIES
RFS
INT
PE
THREE PHASE RANGE
Model
MBPCX 20 T2 0,25kW
MBPCX 20 T4 0,12kW
MBPCX 25 T2 0,75kW
MBPCX 25 T4 0,18kW
MBPCX 28 T2 1,1kW
MBPCX 28 T4 0,18kW
MBPCX 31 T2 1,5kW
MBPCX 31 T4 0,25kW
MBPCX 31 T6 0,12kW
MBPCX 40 T2 5,5kW
MBPCX 40 T2 4kW
MBPCX 40 T4 0,75kW
MBPCX 40 T6 0,25kW
MBPCX 45 T4 1,1kW
MBPCX 45 T6 0,37kW
MBPCX 50 T4 2,2kW
MBPCX 50 T6 0,75kW
MBPCX 56 T4 5,5kW
MBPCX 56 T6 2,2kW
120
R.P.M.
max.
2800
1400
2800
1400
2800
1400
2800
1400
850
2900
2890
1400
900
1400
900
1430
910
1440
940
Max. Curr. (A)
230 400
690
1,17
0,84
3,03
0,84
4,42
1,12
6,01
1,44
1,08
14,2
3,48
1,51
4,74
2,13
8,06
4
9,7
1,68
0,48
1,75
0,48
2,55
0,65
3,48
0,83
0,62
11
8,2
2,01
0,87
2,75
1,23
5
2,3
12
5,6
6,3
6,9
-
Rated Power
kW
Air flow
m3/h
Sound
dB (A)
Weight
Kg
0,25
0,12
0,75
0,12
1,1
0,18
1,5
0,25
0,12
5,5
4
0,75
0,25
1,1
0,37
2,2
0,75
5,5
2,2
800
440
1500
780
2100
1100
2510
1400
920
5590
4080
2710
1930
3650
2700
5440
4090
9150
8100
74
59
80
64
85
69
90
73
64
91
91
76
65
78
68
80
70
82
71
18
9
29
21
20
16
31
24
20
49
47
31
28
65
65
100
90
115
95
R.R.P.
€
1.249,90
1.188,90
1.705,40
1.349,70
2.072,40
1.547,40
2.447,40
1.746,20
1.748,00
4.221,50
3.362,40
2.705,50
2.593,10
5.389,70
5.152,90
6.508,00
6.015,20
8.919,40
7.765,10
ACCESSORIES
ELECTRICAL ACCESSORIES
MECHANICAL ACCESSORIES
www.casals.tv
121
ELECTRICAL ACCESSORIES
REGD-1
Manual single phase speed controller
Speed controller for single phase voltage (230 Vac - 50 Hz) controllable motors by varying the supplied
voltage through angle phase control.
External enclosure in white-ivory plastic. Internal enclosure in polyamide. Maximum room temperature:
35ºC.
Code
Model
300782600
REG
Max. Current
(A)
Voltage
(V)
Weight Kg
1
230
2,35
REGD-1
R.R.P.
€
56,40
Manual single phase speed controller
Specially designed for sinus wave speed control. Only available for single phase fans. Terminal wiring.
Minimum speed adjustable and potentiometer speed control. Sealed box IP-54 box. Light switch pilot. EMC
filter according to the En55014 Standard.
SINGLE PHASE RANGE
Code
Model
960710015
960710030
960710050
960710100
RFS
REG 1.5 A
REG 3 A
REG 5 A
REG 10 A
Max. Current
(A)
Voltage
(V)
1,5
3
5
10
230
230
230
230
R.R.P.
€
74,20
79,80
95,00
167,00
Frequency drive speed controller
Specially designed for speed frequency control. ECM filter included. It complies with the main standards:
UL/CSA, CE and C/TICK. IP-20 protection.
SINGLE PHASE RANGE
Code
960002500
960002501
960002503
960002504
960002505
Model
RFS 2 0,18kW
RFS 2 0,37kW
RFS 2 0,75kW
RFS 2 1,5kW
RFS 2 2,2kW
Single phase inlet (V)
3 phase
outlet
(V)
Max.
Curr.
(A)
Power
kW
Weight
Kg
200/240 Monofásica 50/60 Hz
200/240 Monofásica 50/60 Hz
200/240 Monofásica 50/60 Hz
200/240 Monofásica 50/60 Hz
200/240 Monofásica 50/60 Hz
230V
230V
230V
230V
230V
1,4
2,4
4
7,5
10
0,18
0,37
0,75
1,5
2,2
1
1
1
1,5
1,5
R.R.P.
€
270,70
292,40
335,70
465,70
592,10
THREE PHASE RANGE
122
Code
Model
Single phase inlet (V)
3 phase
outlet
(V)
Max.
Curr.
(A)
960002508
960002510
960002511
960002513
960002514
960002515
960002516
960002517
960002518
960002519
RFS 3 0,75kW
RFS 3 1,5kW
RFS 3 2,2kW
RFS 3 4kW
RFS 3 5,5kW
RFS 3 7,5kW
RFS 3 11kW
RFS 3 15kW
RFS 3 18,5kW
RFS 3 22kW
380/400V Trifásica 50/60 Hz
380/400V Trifásica 50/60 Hz
380/400V Trifásica 50/60 Hz
380/400V Trifásica 50/60 Hz
380/400V Trifásica 50/60 Hz
380/400V Trifásica 50/60 Hz
380/400V Trifásica 50/60 Hz
380/400V Trifásica 50/60 Hz
380/400V Trifásica 50/60 Hz
380/400V Trifásica 50/60 Hz
400V
400V
400V
400V
400V
400V
400V
400V
400V
400V
2,2
3,7
5,1
9,1
12
16
22,5
30,5
41
48
Power Weight
kW
Kg
0,75
1,5
2,2
4
5,5
7,5
11
15
18,5
22
1,4
1,4
1,4
2,4
2,4
4,7
4,7
9
9
15,4
R.R.P.
€
700,30
704,00
725,60
862,80
1.379,00
1.523,40
1.884,40
2.411,40
3.534,10
4.187,60
ELECTRICAL ACCESSORIES
INT
Safety switch
Safety start-stop switch prepared for a safe-lock. Used to stop and lock the fan before any maintenance job.
In compliance with the IEC 947-3 standard. IP-65 protection.
Code
Model
960000512
960000532
INT 3V
Max. Curr. (A)
Protection index
12
32
IP-65
IP-65
INT 12
INT 32
R.R.P.
€
76,30
115,80
Speed selector switch
4 steps (0-1-2-3) start-stop switch selector. Specially designed for the BD3V range.
Code
Model
960000603
PE
Max. Curr. (A)
Protection index
Application
3
IP-44
BD 3V
INT 3V
R.R.P.
€
23,10
Emergency switch
Emergency push button switch, manual twist-release.
NC normally closed.
NC + NA normally closed or normally open.
Code
960002700
960002701
DPS
R.R.P.
€
Model
PE-1 NC
PE-1 NC+NA
88,20
107,00
Differential pressure transmitter
Differential pressure transmitter. It provides a current signal (4-20 mA) proportional to the pressure measurement. It is used together with the RFS (frequency regulator) to control the pressure of an installation.
Code
300671201
Model
Supply
Pressure range
Output signal
DPS 100 AZ
24Vdc
0-100 Pa
4-20 mA
R.R.P.
€
317,70
123
ELECTRICAL ACCESSORIES
MOTORS
Three phase IEC motors
FEATURES
• Speeds: 2, 4 and 6.
• Mounting form: IM B3 (IM 1001).
• Supply: 230/400V 50Hz in three phase motors
up to 4kW, and 400/690V 50Hz for higher powers.
• Closed motors with forced ventilation.
• IP 55 protection.
• Class F insulation.
• Service S1.
2 POLES
4 POLES
6 POLES
Power
kW
Voltage
V
Mounting
form
Price €
Mounting size
Price €
Mounting size
Price €
Mounting size
0,18
0,25
0,37
0,55
0,75
1,10
1,50
2,20
3
4
5,50
7,50
11
15
18,50
22
30
37
40
55
75
90
110
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
400/690
400/690
400/690
400/690
400/690
400/690
400/690
400/690
400/690
400/690
400/690
400/690
400/690
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
B3
73,30
79,50
92,00
98,90
167,70
184,30
214,50
238,00
321,80
392,20
596,60
656,90
998,80
1.043,60
1.207,60
1.546,80
2.053,50
2.280,00
3.111,30
3.760,20
4.275,50
5.376,90
9.995,70
63
63
71
71
80
80
90
90
100
112
135
132
160
160
160
180
200
200
225
250
280
280
315
76,80
92,30
100,50
160,90
177,60
207,80
227,90
294,90
325,10
412,30
596,60
693,30
1.043,60
1.151,70
1.431,20
1.591,40
2.130,70
2.644,20
3.002,10
3.657,80
4.817,00
5.295,60
8.190,60
63
71
71
80
80
90
90
100
100
112
132
132
160
160
180
180
200
225
225
250
280
280
315
89,20
96,20
129,20
138,90
207,80
231,30
318,40
414,90
576,50
656,90
731,50
1.043,60
1.151,70
1.632,20
1.980,70
2.228,90
2.915,40
3.635,90
4.671,90
5.327,40
9.631,70
9.916,10
10.716,30
71
71
80
80
90
90
100
112
132
132
132
160
160
180
200
200
225
250
280
280
315
315
315
TRANSMISSION SETS
124
UNDER REQUEST
• 2 speeds motors.
• Single phase motors.
• Other mounting forms.
Size
Price €
56
63
71
80
90
100
112
132
160
180
200
225
250
280
315
337,60
337,60
337,60
337,60
399,60
570,40
613,10
713,90
1.028,20
1.086,40
1.315,30
1.664,60
1.812,00
2.444,40
5.536,90
Transmission set with belt protection included.
Applicable to the models AAZ and MZ.
ELECTRICAL ACCESSORIES
RP
Protection guard for long cased axial fans
Inlet or outlet protection guard. Specially designed to avoid finger contact. Made of welded metal wire.
According to ROHS 2002/95/EC Directive.
Code
960280100
960290100
960300100
960300101
960310100
960320100
960330100
960330101
960340100
960340101
960340102
960340103
960340104
RP0
Model
RP 25
RP 30
RP 35
RP 40
RP 45
RP 50
RP 56
RP 63
RP 71
RP 80
RP 90
RP 100
RP 125
Application
R.R.P.
€
HM 25
HM 30
HM-HH 35
HM-HMF 40
HM-HMF-HH-HHP 45
HM-HMF 50
HM-HMF-HH-HHP 56
HM-HMF-HH-HHP 63
HM-HMF-HH-HHP 71
HM-HH-HMF 80
HM-HMF-HH-HHP 90
HM-HH 100
HM 125
18,00
21,20
25,30
25,50
29,20
36,70
38,20
69,50
72,90
76,00
78,50
94,80
232,80
Outlet protection guard for axial fans
Outlet protection guard. Specially designed to avoid finger contact. Made of welded metal wire.
According to ROHS 2002/95/EC Directive.
Code
980000020
980000240
980000025
980000280
980000030
960001201
980000035
980000350
960001212
980000040
960001211
980000045
960001202
980000050
960001203
980000056
960001204
960001205
960001206
960001207
960001208
960001209
960001210
Model
RP0 20
RP0 240
RP0 25
RP0 280
RP0 30
RP0 300
RP0 35
RP0 350
RP0 351
RP0 40
RP0 400
RP0 45
RP0 450
RP0 50
RP0 500
RP0 56
RP0 560
RP0 630
RP0 710
RP0 800
RP0 900
RP0 1000
RP0 1250
Application
HJE 20
HA 24
HJE 25
HA 28
HJE-HJB 30
HB 30
HJE-HJB 35
HA 35
HB 35
HJB 40
HB 40
HJB 45
HB 45
HJB 50
HB 50
HJB 56
HB 56
HB 63
HB 71
HB 80
HB 90
HB 100
HB 125
R.R.P.
€
23,60
24,90
25,40
28,00
30,20
30,30
34,30
37,10
38,40
39,80
40,70
42,30
43,60
45,30
48,80
49,10
50,20
65,60
86,30
111,90
130,30
141,10
260,20
125
MECHANICAL ACCESSORIES
GUARDS, SHUTTERS AND DAMPERS
RP1
Inlet protection guard for axial fans
Inlet outlet protection guard. Specially designed to avoid finger contact. Made of welded metal wire.
According to ROHS 2002/95/EC Directive.
Code
RI
Model
960350100
960360100
960360110
960370100
960370101
960460101
960460102
960380101
960380102
960450101
960420100
960420101
960390101
960390102
960410101
960410102
960400100
960400101
RP1 24
RP1 28
RP1 300
RP1 35
RP1 351
RP1 401
RP1 402
RP1 451
RP1 452
RP1 500
RP1 56
RP1 561
RP1 631
RP1 632
RP1 711
RP1 712
RP1 80
RP1 801
960430100
RP1 90
960430101
960440100
960440101
960550100
RP1 901
RP1 100
RP1 1001
RP1 125
Application
R.R.P.
€
HA 24
HA 28
HB 30
HA 35
HB 35
HB 40 T4
HB 40 T2
HB-HBA-45 T4, T6
HB 45 T2
HB 50
HB 56 T4 0,55kW, T4 0,75kW, T6
HB T4 1,1kW, T4 1,5kW
HB 63 T4 0,75kW, T4 1,1kW, T4 1,5kW, T6
HB 63 T4 2,2kW, T4 3kW
HB 71 T4 1,1kW, T4 1,5kW, T6
HB 71 T4 2,2kW, T4 3kW
HB 80 T6 0,75kW, T6 1,1kW, T8 0,37kW, T8 0,55kW
HB 80 T4 2,2kW, T4 3kW, T4 4kW, T6 1,5kW,
T6 2,2kW, T8 0,75kW
HB 90 T4 3kW, T4 4kW, T6 1,5kW, T6 2,2kW, T8
0,75kW, T8 1,1kW, T8 1,5kW
HB 90 T4 5,5kW, T4 7,5kW, T6 3kW, T8 2,2kW
HB 100 T4 5,5kW, T4 7,5kW, T6, T8
HB 100 T4 11kW, T4 15kW
HB 125
28,10
33,10
34,10
48,80
49,30
55,20
57,10
63,90
64,10
89,30
90,10
90,90
141,40
144,00
163,30
165,90
144,10
183,70
188,70
192,00
206,40
213,20
369,90
Outlet protection guard for BD and BV fans
Outlet protection guard. Specially designed to avoid finger contact. Made of welded metal wire.
Code
960000401
960000402
960000403
960000404
960000405
960000406
960000407
960000408
960000409
960000411
RM
Model
Application
RI-19
RI-25/13
RI-25/20
RI-25
RI-28/21
RI-28
RI-33/25
RI-33
RI-39
RI-47
R.R.P.
€
BD-BV 7/7
BD-BV 9/5
BD-BV 9/8
BD-BV 9/9
BD-BV 10/8
BD-BV 10/10
BD-BV 12/9
BD-BV 12/12
BD-BV 15/15
BV 18/18
18,20
17,50
17,00
18,50
28,00
28,30
37,00
37,00
54,60
69,90
Motor side inlet protection guard for BD fans
Motor side protection guard specially designed for low pressure direct driven fans.
Code
960000801
960000803
960000802
960000804
960000805
126
Model
RM-19
RM-25
RM-25/13
RM-28
RM-33
Application
BD 7/7
BD 9/9
BD 9/5
BD 10/10
BD 12/12, BD 12/9
R.R.P.
€
12,60
18,80
18,00
19,70
34,60
MECHANICAL ACCESSORIES
GUARDS, SHUTTERS AND DAMPERS
RA-RAI
Inlet protection guard for centrifugal fans
Inlet protection guard. Specially designed to avoid finger contact. RA 19-39 model made of galvanised
steel; RA 10/4-71/22 made of steel with epoxy powder finishing coat; RAI made of stainless steel AISI 304.
Code
RA 19-39
RA 10/4-71/22
Model
960610100
960630100
960650100
960670100
960690100
RA 19
RA 25
RA 28
RA 33
RA 39
253051901
253061901
253101901
253111901
253171901
253191901
253201901
253281901
RA 10/4
RA 12/5
RA 14/5
RA 16/6
RA 18/7
RA 20/6
RA 22/9
RA 25/10
253361901
253451901
RA 28/11
RA 31/12
253481901
RA 35/14
253511901
RA 40/16
253531901
RA 45/18
243501901
243561901
254541901
RA 50/16
RA 56/18
RA 63/20
243711901
300716102
300716202
300716302
300716502
300716702
300716902
300717102
300717302
300717402
Application
R.R.P.
€
BD 7
BD 9
BD 10
BD 12
BD 15
11,80
16,40
16,40
27,80
37,90
6,30
6,40
6,40
9,40
13,90
12,60
15,10
16,00
RA 71/22
MB 10/4, MA 18-24, MA 24 P/R
MB 12/5, MA 25-26, MA P/R 25-26
MB 14/5, MA 27-28, MA P/R 27-28
MB 16/6, AA 47-53, MA 31, MA 31 P/R
MB 18/7, AA 59-66-70-45/5, AA P/R 45/5
MB 20/6-20/8
MB 22/9, AA 50/5, AA P/R 50/5, BC 25/10, MZ 22/9, MB P/R 22/9
MB 25/10, MBC 25/10, AA 60/7, AA P/R 60/7, BC 28/11,
MBC/FA 25/10, MZ 25/10, MB P/R 25/10
MB 28/11, MBC 28/11, MZ 28/11, MB P/R 28/11
MB 31/12, MBC 31/12, MBR 31/12, MZ 31/12, MBRC 31/10,
MBR 31/10, MBC/FA 31/12, BC 35/18, MB P/R 31/12
MB 35/14, MBC 35/14, MBRC 35/11, MBC/FA 35/14, MBR 35/11,
MZ 35/11, MZ 35/14, MB P/R 35/14
MB 40/16, MBC 40/16, MZ 40/16, MB P/R 40/16, MBRF 40/12,
MBC/FA 40/16, MBR 40/12, MBRC 40/12, MBRC/FA 40/12
MB 45/18, MBR 45/14, MBC 45/18, MBC/FA 45/18, MZ 45/18,
MBRF 45/14, MBRC 45/14, MBRC/FA 45/14, MB P/R 45/18
MBR 50/16, MBRF 50/16, MBRC 50/16, MBRC/FA 50/16
MBR 56/18, MBRF 56/18, MBRC 56/18, MBRC/FA 56/18
MBR 63/20, MBRC 63/20, MBRC/FA 63/20, MBRF 63/20,
MZ 63/20, MZ 63/25
MBR 71/22, MBRF 71/22, MBRC 71/22, MBRC/FA 71/22
RAI 10/5
RAI 12/6
RAI 13/6
RAI 13/8
RAI 16/8
RAI 18/8
RAI 20/10
RAI 25/13
RAI 28/15
MDI 10/5
MDI 12/6
MDI 13/6
MDI 13/8
MDI 16/8
MDI 18/8
MDI 20/10
MDI 25/13
MDI 28/15
18,70
25,20
25,90
31,50
48,60
59,60
61,30
77,60
74,50
25,20
25,60
29,60
30,50
37,50
55,80
50,30
64,00
75,10
Additional models under inquiry
RAI
127
MECHANICAL ACCESSORIES
GUARDS, SHUTTERS AND DAMPERS
PC
Metall gravity shutter
Steel sheet frame and aluminium slats.
Code
963200100
963220100
963230100
963240100
963250100
963260100
963280100
963290100
PCP
Model
PC 25
PC 30
PC 35
PC 45
PC 56
PC 71
PC 90
PC 100
Application
HA 24-HJEPA 20-HJEPA 25
HA 28-HJEPA-HB-HJBPA 30
HJEPA-HA-HJBPA-HH 35
HJBPA 40, HJBPA-HB-HH-HHP 45
HH-HJBPA 50, HJBPA-HB-HH-HHP 56
HB-HH-HHP 63-71
HH 80, HH-HHP 90, HB 80-90
HB 100
R.R.P.
€
61,30
61,00
78,20
154,40
204,40
211,20
260,90
277,20
Plastic gravity shutter
Totally made of PVC. UV rays protected.
Maximum air speed: 16m/s.
Code
963190105
963200105
963220105
963230105
963230106
963240105
963240106
963250105
963250106
963260105
963270105
963280105
963290105
PI
Model
PCP 20
PCP 25
PCP 30
PCP 35
PCP 40
PCP 45
PCP 50
PCP 56
PCP 63
PCP 71
PCP 80
PCP 90
PCP 100
Application
HJEPA 20
HA 24-HJEPA 25
HA 28-HJEPA-HB-HJBPA 30
HJEPA-HA-HJBPA-HH 35
HJBPA 40
HJBPA-HB-HH-HHP 45
HJBPA-HB 50
HJBPA-HB-HH-HHP 56
HJBPA-HB-HH-HHP 63
HB-HH-HHP 71
HH - HB - HBA 80
HH-HHP 90, HB 90
HB 100
R.R.P.
€
58,20
56,60
61,30
71,70
71,80
101,90
130,00
173,70
220,50
307,70
344,60
426,60
530,30
Gravity shutter for cabinet fans
To be assembled on BVFC, BOX BD and BOX BV fans.
Frame and slats made of galvanized steel.
Code
970190100
970250100
970280100
970330100
970390100
970470100
128
Model
PI 19/19 (7/7)
PI 25/25 (9/9)
PI 28/28 (10/10)
PI 33/33 (12/12)
PI 39/39 (15/15)
PI 47/47 (18/18)
Application
BOX BD, BOX BV 7/7
BVFC, BOX BD, BOX BV 9/9
BVFC, BOX BD, BOX BV 10/10
BVFC, BOX BD, BOX BV 12/12
BVFC, BOX BD, BOX BV 15/15
BVFC, BOX BD, BOX BV 18/18
R.R.P.
€
57,50
69,50
84,10
108,10
130,60
189,90
MECHANICAL ACCESSORIES
GUARDS, SHUTTERS AND DAMPERS
OM
Butterfly shutter for HTE roof fans
Gravity butterfly shutter. Outlet side fitted.
Code
963030101
963040101
963050101
963060101
963070101
VIS
Model
OM 35
OM 40
OM 45
OM 50
OM 56
Application
HTE 35
HTE 40
HTE 45
HTE 50
HTE 56
R.R.P.
€
85,30
89,80
93,80
98,90
110,10
Outdoor flange with bird guard
VIS OUT = Outlet VIS IN = Inlet
Code
960000059
960000050
960000051
960000052
960000053
960000054
960000055
960000056
960000057
960000058
960000051
960000052
960000053
960000054
960000060
960000061
960000062
960000063
960000064
960000065
Model
VIS OUT 7
VIS OUT 9
VIS OUT 10
VIS OUT 12
VIS OUT 15
VIS OUT 18
VIS OUT 20
VIS OUT 22
VIS OUT 25
VIS OUT 30
VIS IN 7
VIS IN 9
VIS IN 10
VIS IN 12
VIS IN 15
VIS IN 18
VIS IN 20
VIS IN 22
VIS IN 25
VIS IN 30
Application
BOX BV, BOX BD 7/7, CLEAN AIR, TWIN BOX
BVFC, BOX BV, BOX BD 9/9, CLEAN AIR, TWIN BOX
BVFC, BOX BV, BOX BD 10/10, CLEAN AIR, TWIN BOX
BVFC, BOX BV, BOX BD 12/12, CLEAN AIR, TWIN BOX
BVFC, BOX BV, BOX BD 15/15, CLEAN AIR, TWIN BOX
BVFC, BOX BV 18/18, CLEAN AIR, TWIN BOX
BVFC, BOX BV 20/20
BVFC, BOX BV 22/22
BVFC, BOX BV 25/25
BVFC, BOX BV 30/28
BOX BV, BOX BD 7/7
BOX BV, BOX BD 9/9
BOX BV, BOX BD 10/10
BOX BV, BOX BD 12/12
BOX BV, BOX BD 15/15
BOX BV 18/18
BOX BV 20/20
BOX BV 22/22
BOX BV 25/25
BOX BV 30/28
R.R.P.
€
49,80
57,90
65,30
70,30
82,40
108,20
137,70
160,60
183,60
206,40
65,30
70,30
82,40
108,20
127,30
140,00
163,00
178,30
210,10
318,20
129
MECHANICAL ACCESSORIES
GUARDS, SHUTTERS AND DAMPERS
S
Mounting support for low pressure fans
Support to fix centrifugal low pressure fans on flat surfaces.
Fans from 7/7 (19/19) to 12/12 (33/33) supplied with supports (included in price).
Code
960540100
PO
960001651
960001652
960001653
960001654
960001655
960001656
960001657
960001658
960001659
960001660
960001661
960001662
960001663
BDE-BV 15/15 BV 18/18
R.R.P.
€
22,70
Model
PO 25
PO 30
PO 35
PO 40
PO 45
PO 50
PO 56
PO 63
PO 71
PO 80
PO 90
PO 100
PO 125
Application
HM 25
HM 30
HM, HMF, HH 35
HM, HMF 40
HM, HMF, HH, HHP 45
HM, HMF 50
HM, HMF, HH, HHP 56
HM, HMF, HH, HHP 63
HM, HMF, HH, HHP 71
HM, HMF 80
HM, HMF, HH, HHP 90
HM 100
HM 125
R.R.P.
€
22,60
21,40
23,40
24,10
24,60
41,20
41,90
45,00
49,60
50,90
61,80
63,40
74,50
Tilt mounting support for HM
Code
960110101
960100101
960120101
960130101
960150101
960140101
130
S 15/18
Application
Long cased axial fans mounting support
Code
PS
Model
Model
PS 35
PS 40
PS 45
PS 56
PS 63
PS 71
Application
HM 35
HM 40
HM, HMF, HH 45
HM, HMF 56
HM, HMF, HH, HHP 63
HM, HMF 71
R.R.P.
€
139,70
142,10
144,20
166,30
174,40
175,40
MECHANICAL ACCESSORIES
SUPPORTS, FEET AND BASES
BTI
Inclined roof fan support
Inclination under request.
Code
BTI 25
BTI 30
BTI 35
BTI 40
BTI 45
BTI 50
BTI 56
BTI 63
BTI 71
BTI 80
BTI 90
BS
Model
HMTE 25
HMTE 30
HMTE, HTE 35
HTE 40
HMTE, HTE 45
HTE 50
HMTE, HTE 56
HMTE 63
HMTE 71
HMTE 80
HMTE 90
Application
HM 25
HM 30
HM, HMF, HH 35
HM, HMF 40
HM, HMF, HH, HHP 45
HM, HMF 50
HM, HMF, HH, HHP 56
HM, HMF, HH, HHP 63
HM, HMF, HH, HHP 71
HM, HMF 80
HM, HMF, HH, HHP 90
R.R.P.
€
274,70
274,70
274,70
274,70
345,40
345,40
345,40
345,40
608,30
608,30
608,30
Motor support for BVC and BVCR fans
Designed to assemble the motor on the fan and tighten the belts.
Code
960000100
960000101
960000102
960000103
960000104
TM
Model
BS 25
BS 28
BS 33
BS 39
BS 47
Application
BVC-BVCR 9/9
BVC-BVCR 10/10
BVC-BVCR 12/12
BVC-BVCR 15/15
BVC-BVCR 18/18
R.R.P.
€
78,80
95,10
99,20
110,30
100,00
Motor support for BV fans
Designed to assemble the motor on the fan and tighten the belts.
Code
960720100
960730100
960740100
960750100
960760100
960770100
960780100
960790100
Model
TM 251
TM 25
TM 281
TM 28
TM 331
TM 33
TM 39
TM 47
Application
BV 7/7, BV 9/7
BV 9/9
BV 10/8
BV 10/10
BV 12/9
BV 12/12
BV 15/15
BV 18/18
R.R.P.
€
13,70
17,00
16,00
16,80
18,40
23,10
26,00
28,60
131
MECHANICAL ACCESSORIES
GUARDS, SHUTTERS AND DAMPERS
AC
Connection lange
For axial (inlet or outlet) and centrifugal (inlet) fans.
Code
AC 80-225
AC 250-1250
962100100
962120101
962140101
962160101
962180101
962200101
962220101
960003208
960003209
960003211
960003212
960003213
960003214
960003215
960003216
960003217
960003218
960003219
960003220
960003222
Model
AC 80
AC 100
AC 130
AC 150
AC 175
AC 200
AC 225
AC 250
AC 300
AC 350
AC 400
AC 450
AC 500
AC 560
AC 630
AC 710
AC 800
AC 900
AC 1000
AC 1250
Application
MB 10/4, MA 18-24
MB 12/5, MA 25-26
MB 14/5, MA 27-28
MB 16/6, MA 31, AA 47-53
MB 18/7, AA 45/5-59-66-70
MB 20/6-20/8
MB-MZ 22/9, AA 50/5, BC 25/10
HM 25
HM 30
HM-HH 35
HM 40
HM-HH-HHP 45
HM-HMF 50
HM-HMF-HH-HHP 56
HM-HMF-HH-HHP 63
HM-HMF-HH-HHP 71
HM-HMF-HH 80
HM-HMF-HH-HHP 90
HM-HH 100
HM 125
R.R.P.
€
32,70
33,60
36,00
38,40
41,70
44,60
46,80
57,30
66,10
76,60
85,40
98,50
100,20
110,70
129,10
148,40
185,10
216,00
230,50
302,20
Additional models under request
EI
Circular outlet connection flange
Square to circular conversion flange for medium and high pressure centrifugal fans.
Code
962100111
962120111
962140111
962160111
962180111
962200111
962200112
962220111
962250111
962280111
962310111
962310112
962350111
962400111
962400112
962450111
962450112
962500111
962500112
962560111
962600111
962630111
962710111
962250112
962280112
962350112
962470111
Model
EI 10/4
EI 12/5
EI 14/5
EI 16/6
EI 18/7
EI 20/6
EI 20/8
EI 22/9
EI 25/10
EI 28/11
EI 31/12
EI 31/10
EI 35/14
EI 40/16
EI 40/12
EI 45/18
EI 45/5
EI 50/16
EI 50/5
EI 56/18
EI 60/7
EI 63/25
EI 71/22
EI 25
EI 28
EI 35
EI 47
Additional models under request
132
Application
MB 10/4
MB 12/5
MB 14/5
MB 16/6
MB 18/7
MB 20/6
MB 20/8
MB-MZ 22/9
MB-MZ-MBC-MBC/FA 25/10
MB-MZ-MBC-MBC/FA 28/11
MB-MZ-MBC-MBC/FA 31/12
MBR 31/10
MB-MZ-MBC-MBC/FA 35/14, MBR 35/11
MB-MZ-MBC-MBC/FA 40/16
MB-MBR-MBRF-MBC/FA-MBRC/FA 40/12
MB-MZ-MBC-MBC/FA 45/18
AA 45/5
MBR-MBRF-MBC/FA-MBRC/FA 50/16
AA 50/5
MBR-MBRF-MBC/FA-MBRC/FA 56/18
AA 60/7
MZ 63/25, MBR-MBRF-MBC/FA-MBRC/FA 63/20
MBR-MBRF-MBC/FA-MBRC/FA 71/22
BC 25/10
BC 28/11
BC 35/18
AA 47-53-59-66-70
R.R.P.
€
76,10
108,00
113,50
117,90
117,90
111,40
126,60
134,50
155,00
161,40
163,70
173,80
178,20
196,40
204,80
216,00
124,70
257,00
148,10
243,90
147,80
265,70
313,90
155,90
158,40
179,10
104,90
MECHANICAL ACCESSORIES
COUPLING FLANGES, DAMPER COVERS AND FILTERS
MBI
Outlet flange for BD and BV fans
Code
251161691
251261691
251281691
251331691
251371691
251601691
251521691
252371691
252451691
Model
MBI 7/7
MBI 9/7
MBI 9/9
MBI 10/8
MBI 10/10
MBI 12/9
MBI 12/12
MBI 15/15
MBI 18/18
Application
BD, BDE, BV 7/7
BD, BV 9/7
BD, BDE, BV 9/9
BD, BV 10/8
BD, BDE, BV 10/10
BD, BV 12/9
BD, BDE, BV 12/12
BD, BV 15/15
BD, BV 18/18
R.R.P.
€
9,70
10,60
12,30
17,30
13,50
16,30
15,40
20,80
29,10
UNDER REQUEST: Possible spot welding on fans outlet.
MC HB
Square frame for HB fans
Code
960003151
960003152
960003153
960003154
960003155
960003156
960003157
960003158
960003159
960003160
960003161
Model
MC HB 30
MC HB 35
MC HB 40
MC HB 45
MC HB 50
MC HB 56
MC HB 63
MC HB 71
MC HB 80
MC HB 90
MC HB 100
Application
HB 30
HB 35
HB 40
HB 45
HB 50
HB 56
HB 63
HB 71
HB 80
HB 90
HB 100
R.R.P.
€
49,10
60,60
71,80
81,10
90,10
97,40
108,40
112,50
136,80
182,10
224,20
133
MECHANICAL ACCESSORIES
COUPLING FLANGES, DAMPER COVERS AND FILTERS
BA-400
Flexible flange 400ºC/2h
Avoids transmission of vibrations to the installation. Certified according to the European standard EN
12101-3 400ºC/2h.
Code
960002068
960002067
960002066
960002051
960002065
960002052
960002053
960002054
960002055
960002064
960002056
960002057
960002058
960002059
960002061
960002062
960002063
JE 45
Model
BA-400 10/12
BA-400 15
BA-400 20
BA-400 25
BA-400 28
BA-400 30
BA-400 35
BA-400 40
BA-400 45
BA-400 50
BA-400 56
BA-400 63
BA-400 70
BA-400 80
BA-400 90
BA-400 100
BA-400 125
Application
Ø 100/125 x 160
Ø 160 x 160
Ø 200 x 160
Ø 250 x160
Ø 280 x 160
Ø 315 x 160
Ø 350 x 160
Ø 400 x 160
Ø 460 x 160
Ø 510 x 160
Ø 570 x 160
Ø 630 x 160
Ø 720 x 160
Ø 810 x 160
Ø 910 x 160
Ø 1010 x 160
Ø 1250 x 160
R.R.P.
€
40,60
42,50
45,00
47,30
48,90
50,80
52,70
55,20
58,00
64,20
70,40
68,00
88,60
77,10
85,70
86,50
161,10
Flexible joint
Flexible joint to fix the fan and the ducting. Avoids transmission of vibrations.
Dimensions: two metallic flanges of 45mm each one and a flexible flange of 60mm.
Code
300719201
TCA
Model
JE 45
Application
45 x 60 x 45
R.R.P.
€
6,80
Inlet blind cover
Allows customization of inlet’s position and shape.
Code
960001111
960001112
960001113
960001114
960001115
960001121
960001122
960001123
960001124
960001125
960001131
134
Model
TCA6
TCA7
TCA8
TCA9
TCA10
TCA11
TCA12
TCA13
TCA14
TCA15
TCA16
Application
BOX BD, BOX BV 7/7
BOX BD, BOX BV 9/9
BOX BD, BOX BV 10/10
BOX BD, BOX BV 12/12
BOX BD, BOX BV 15/15
BOX BV 18/18
BVFC 9/9
BVFC 10/10
BVFC 12/12
BVFC 15/15
BVFC 18/18
R.R.P.
€
17,90
20,70
21,70
22,80
25,10
27,10
20,70
21,70
22,80
25,10
27,10
MECHANICAL ACCESSORIES
COUPLING FLANGES, DAMPER COVERS AND FILTERS
TIAC
Inlet-outlet round flanges
Allows duct connection.
Code
Model
960001351
960001352
960001353
960001354
960001355
960001356
960001357
960001358
960001359
960001360
960001361
960001362
960001363
960001364
960001365
960001366
960001367
CP
TIAC 1
TIAC 2
TIAC 3
TIAC 4
TIAC 5
TIAC 6
TIAC 7
TIAC 8
TIAC 9
TIAC 10
TIAC 11
TIAC 12
TIAC 13
TIAC 14
TIAC 15
TIAC 16
TIAC 17
Application
Ø 250 TAPA IMPULSIÓN BOX BD-BV-CA 7/7 CIRCULAR
Ø 300 TAPA IMPULSIÓN BOX BD-BV-CA 9/9 CIRCULAR
Ø 355 TAPA IMPULSIÓN BOX BD-BV-CA 10/10 CIRCULAR
Ø 400 TAPA IMPULSIÓN BOX BD-BV-CA 12/12 CIRCULAR
Ø 500 TAPA IMPULSIÓN BOX BD-BV-CA 15/15 CIRCULAR
Ø 600 TAPA IMPULSIÓN BOX BV-CA BVFC 18/18 CIRCULAR
Ø 300 TAPA ASPIRACIÓNBVFC 9/9 CIRCULAR
Ø 355 TAPA ASPIRACIÓNBVFC 10/10 CIRCULAR
Ø 400 TAPA ASPIRACIÓNBVFC 12/12 CIRCULAR
Ø 500 TAPA ASPIRACIÓNBVFC 15/15 CIRCULAR
Ø 600 TAPA ASPIRACIÓNBVFC 18/18 CIRCULAR
Ø 250 TAPA ASPIRACIÓN BOX BD-BV-CA 7/7 CIRCULAR
Ø 300 TAPA ASPIRACIÓN BOX BD-BV-CA 9/9 CIRCULAR
Ø 355 TAPA ASPIRACIÓN BOX BD-BV-CA 10/10 CIRCULAR
Ø 400 TAPA ASPIRACIÓN BOX BD-BV-CA 12/12 CIRCULAR
Ø 500 TAPA ASPIRACIÓN BOX BD-BV-CA 15/15 CIRCULAR
Ø 600 TAPA ASPIRACIÓN BOX BV-CA 18/18 CIRCULAR
R.R.P.
€
28,10
34,50
37,40
43,40
48,90
73,10
37,30
39,50
47,40
63,00
79,20
28,10
34,50
37,40
43,40
48,90
73,10
Outlet bend for MBRLP fans
90º bend for vertical discharge, often needed in paint booths.
Code
Model
960002100
960002101
960002102
FILTERS
CP 454
CP 503
CP 561
Application
MBRLP 454
MBRLP 503
MBRLP 561
R.R.P.
€
248,50
248,50
248,50
Low pressure drop filters for RCIB (heat exchanger)
Model
FILTRO G4 RCIB 600
FILTRO G4 RCIB 900
FILTRO G4 RCIB 1900
FILTRO G4 RCIB 2800
FILTRO G4 RCIB 3700
FILTRO G4 RCIB 5100
FILTRO F5 RCIB 600
FILTRO F5 RCIB 900
FILTRO F5 RCIB 1900
FILTRO F5 RCIB 2800
FILTRO F5 RCIB 3700
FILTRO F5 RCIB 5100
FILTRO F7 RCIB 600
FILTRO F7 RCIB 900
FILTRO F7 RCIB 1900
FILTRO F7 RCIB 2800
FILTRO F7 RCIB 3700
FILTRO F7 RCIB 5100
FILTRO F9 RCIB 600
FILTRO F9 RCIB 900
FILTRO F9 RCIB 1900
FILTRO F9 RCIB 2800
FILTRO F9 RCIB 3700
FILTRO F9 RCIB 5100
Application
RCIB 600
RCIB 900
RCIB 1900
RCIB 2800
RCIB 3700
RCIB 5100
RCIB 600
RCIB 900
RCIB 1900
RCIB 2800
RCIB 3700
RCIB 5100
RCIB 600
RCIB 900
RCIB 1900
RCIB 2800
RCIB 3700
RCIB 5100
RCIB 600
RCIB 900
RCIB 1900
RCIB 2800
RCIB 3700
RCIB 5100
R.R.P.
€
37,20
41,90
55,80
65,20
74,50
74,50
107,00
125,70
135,00
144,30
148,90
148,90
102,40
125,70
223,40
283,90
423,50
423,50
107,00
130,30
228,00
293,20
432,80
432,80
135
MECHANICAL ACCESSORIES
SILENCERS AND SOUNDPROOF CABINETS
SIL-C
Circular silencer
Designed to reduce fan noise and be assembled to circular fans and ducts. Special connection flanges
might be needed to connect directly to fans (please contact the technical service).
Code
960002200
960002201
960002202
960002203
960002204
960002205
960002206
960002207
960002208
960002209
960002210
960002211
960002212
960002213
960002214
960002215
960002216
960002217
SIL-R
Model
Application
SIL-C 100/600
SIL-C 125/600
SIL-C 150/600
SIL-C 160/900
SIL-C 200/900
SIL-C 250/900
SIL-C 315/900
SIL-C 355/900
SIL-C 400/1200
SIL-C 500/1200
SIL-C 560/1200
SIL-C 560/1500
SIL-C 630/1200
SIL-C 630/1500
SIL-C 710/1500
SIL-C 800/1500
SIL-C 900/1500
SIL-C 1000/1500
Ø 100
Ø 125
Ø 150
Ø 160
Ø 200
Ø 250
Ø 315
Ø 355
Ø 400
Ø 500
Ø 560
Ø 560
Ø 630
Ø 630
Ø 710
Ø 800
Ø 900
Ø 1000
R.R.P.
€
126,90
130,50
155,10
173,80
216,50
287,90
423,50
523,30
600,00
721,40
872,40
1.013,60
1.023,30
1.189,00
1.393,20
1.597,30
1.943,00
2.177,00
Rectangular silencer
Designed to reduce fan noise, rectangular duct connection.
Code
960002300
960002301
960002302
960002303
960002304
960002305
960002306
960002307
960002308
CI
Model
SIL-R 1000/900/900
SIL-R 1200/900/900
SIL-R 1400/1200/900
SIL-R 1400/1200/1200
SIL-R 1600/1200/1200
SIL-R 1800/1200/1200
SIL-R 1800/1500/1200
SIL-R 2000/1800/1200
SIL-R 2400/1800/1200
Noise reduction cabinet
Noise reduction cabinet for centrifugal fans.
Only under request.
136
Application for air-flow up to:
(m3/h)
19450
23350
36280
36280
41470
46650
58320
77750
93300
R.R.P.
€
1.264,00
1.482,40
2.187,00
2.515,00
2.841,70
3.160,40
4.038,10
4.875,90
5.781,30
TECHNICAL CONCEPTS
www.casals.tv
137
MECHANICAL VENTILATION IN GARAGES
In March 2007 the complete Edification Technical Code (CTE) came into effect. Its health (HS) and security basic documents in case of fire state establish,
among other issues, the standards for mechanical ventilation devices in garages.
Mechanical ventilation shall be done through depression and can be effectuated either by mechanical extraction or by mechanical extraction and
impulsion.
The basic security document in case of fire indicates that the system must be able to extract an air flow of 150l/s for each place, with a maximum contribution of 120l/s per place. This flow coincides with the denoted on the HS3.
The number of extraction devices is based on the number of parking places (see table below). Each duct net must have an extractor.
PARKING PLACES (P)
DUCT NETS
P<15
1
15≤P≤80
2
P>80
1 + Integral (P/40)
Garages shall have an extraction and inlet opening for every 100m2 of useful area. The distance between the closest extraction openings shall be below
10m.
Fans, including the belt driven ones to overcome pressure drops and/or regulate the flow, must have the F30060 classification.
There exist 2 basic types of certified fans: those installed inside the hazardous area and those installed outside the hazardous area.
138
STAIR PRESSURIZATION
The UNE-EN 12101-6 standard describes the differential pressure systems applied to escape ways, specially in protected stairs. These systems are based
on the mechanical injection of outdoor air to the stair box, generating in this way a positive pressure that prevents the products of combustion from getting in the escape ways. In case of fire, the system helps in the evacuation process of the occupants by avoiding or reducing the vertical spread of the fire.
The needed flow will depend on the design conditions of the building. In general terms, an air speed through open sections of 0.75m/s will be used
when the stair is used as an escape way for occupants, and of 2m/s when the stair is used by the fire extinguishing personnel.
The pressurization system must keep a differential pressure of 50Pa and overcome the pressure drop of the installation.
An automatic system consisting of a differential pressure probe (DPS), a frequency regulator (RFS) and the right fan according to the needs is recommended.
2m/s
2m/s
Air speed criterium
50 Pa
Differential pressure criterium
(with all doors closed)
KITCHEN VENTILATION
Industrial kitchens are considered areas of special risk as long as the total installed power of the cooking elements is higher than 20kW. These conducts
must be independent from any other extraction or ventilation conduct. Smoke and heat mechanical extractors will be classified as F40090.
The extraction flow rate will be estimated from the uptake speed of the base of the range hood. The uptake speed of the base of the range hood will vary
depending on its number of open sides. The following uptake speeds are recommended: 0.6m/s in island type range hoods (4 open sides), 0.45m/s
in range hoods with 3 open sides, 0.35m/s in range hoods with 2 open sides and 0.25m/s in range hoods with 1 open side.
139
Fans for potentially explosive environments (ATEX)
For adjustable locations
ATEX
ATEX fans are equipped with certified motors and sparkproof devices.
The purpose of these mentioned devices is to avoid accidental frictions between the static and the rotatory parts of the fan.
Protection aluminium rings are used in axial fans to protect the impeller from the outer main cover. Friction between the aluminium parts does not
generate sparks.
ATEX SYMBOLS ACCORDING TO CURRENT REGULATION 94/9/CE
II 2
G
II B
T5
TYPE OF TEMPERATURE
GAS GROUP
GAS (G) AND DUST (D)
GROUP AND CATEGORY
ATEX LOGO
DECLARATION OF CONFORMITY (EC)
MAIN POINTS TO SELECT AN ATEX FAN
1. Fan Group
GROUP I: fans used to work in mine sites. Casals does not manufacture this particular type of fans.
GROUP II: fans used in possible explosive environments. Casals manufactures this type.
2. Fan Category according to risk zone
GROUP AND CATEGORY
RISK ZONE
22
NOT AVAILABLE
DUST
ALWAYS PRESENT
21
20
II 2
3
2
PROBABLY
0
II 3
self-aproval
by manufacturer
1
ACCIDENTAL
2
GAS
Example 1: in a risk zone 1 (gas, explosive environment) a fan from II 2G category is appropriate (where II indicates the group and G indicates gas).
Example 2: in a risk zone 22 (dust, accidental explosive environment) a fan from category II 3D is appropriate (where II indicates the group and D
indicates dust).
140
Fans for potentially explosive environments (ATEX)
For adjustable locations
3. Group and type of temperature
Group: determines the explosion level of the gas.
Type of temperature: determines the highest acceptable surface temperature on motor surface. Overcoming such temperature implies ignition risks of either
the gas or the dust.
GAS
EXPLOSION GROUP
Ignition temperature
I
IIA
Ignition energy
higher than 0,18mJ
TYPE OF TEMPERATURE ( maximum surface temperature allowed)
T1
T2
>450ºC
>300ºC
T3
T4
T5
T6
>100ºC
>85ºC
>200ºC
>135ºC
Methane
I-amyl acetate
Amyl alcohol
Acetaldehyde
Acetone
n-butane
Petrols
Ammonia
n-butanol
Diesel oils
Benzene
1-butene
Heating oils
Ethylacetate
Propylacetate
n-hexane
Methane
I-propanol
Methanol
Vinyl chloride
Propane
Toluene
IIB
Ignition energy
0,06 a 0,18 mJ
Cyanide
hydrogen
Coal Gas
(lighting gas)
1.3-butadleno
Dimethylether
1.4-dioxane
Ethyloglicol
Ethylene
Sulfide hydrogen
Diethylether
Ethylene oxide
IIC
Ignition energy
lower than 0,06mJ
Hydrogen
Carbon
disulphur
Acetylene
DUST
Ignition temperature
dust cloud
Ignition temperature for
5mm dust layer
Lower explosive limit
(LEL)
Dust aluminium
530ºC
280ºC
15 g/m3
Brown dust
380ºC
225ºC
60 g/m3
Dust steel
310ºC
300ºC
125 g/m3
Cereals
420ºC
290ºC
60 g/m3
Wood dust
400ºC
300ºC
30 g/m3
Dust milk
440ºC
340ºC
60 g/m3
Paper
540ºC
300ºC
30 g/m3
PVC
530ºC
380ºC
60 g/m3
Soot
620ºC
385ºC
60 g/m3
Sulfide
280ºC
280ºC
30 g/m3
Starch
440ºC
290ºC
125 g/m3
Hard coal
590ºC
245ºC
60 g/m3
Wheat flour
480ºC
450ºC
125 g/m3
Dust zinc
570ºC
440ºC
250 g/m3
Product (dust)
141
Fans for potentially explosive environments (ATEX)
For adjustable locations
Maximum surface temperature.
(Necessary indication for equipment due to be used in explosive dust environments)
Maximum surface temperature in case of failure for equipments in contact with dust:
- Temperature limit 1 = 2/3 of the minimum ignition temperature for the existing dust.
- Temperature limit 2 = Minimum ignition temperature for a 5mm powder layer less 75 Kelvin.
The lowest limit temperature in both cases has to be higher than the maximum temperature on the device’s surface.
For example, in a wheat flour case:
Temperature limit 1 = 2/3 x 480 = 320 ºC
Temperature limit 2 = 450 – 75 = 375 ºC
Maximum temperature of device’s surface = 320ºC
Lower explosion limit (LEL) is in this case 125g/m3. Below this concentration there’s no explosion risk.
The following types of temperature are determined according the same criteria as with Gas:
TYPE OF TEMPERATURE
Type of temperature
Casing surface maximum
temperature with environment temperature 40ºC
T1
T2
T3
T4
T5
T6
450ºC
300ºC
200ºC
135ºC
100ºC
85ºC
Following the same wheat flour example, the type of temperature is T2.
Furthermore, the motors (engines) for zone 21 have to be IP6X (dust tight).
The client is responsible for defining the potential explosive zones where the fans have to be installed.
STANDARD ASSEMBLY POSITION
Standard industrial fan range assembly position is LG270. The viewer is located in front of the motor
LG 0
LG 180
142
RD 0
LG 45
RD 45
RD 180
LG 225
RD 225
LG 90
LG 270
RD 90
LG 135
RD 270
LG 315
RD 135
RD 315
Fans for potentially explosive environments (ATEX)
For adjustable locations
NECESSARY INFORMATION FOR DEFINING PRODUCTS WHICH SHOULD WORK IN EXPLOSION ENVIRONMENTS ACCORDING TO ATEX DIRECTIVE.
Customer: Reference: Date: Contact person: Telephone: Fax: Email: ATEX marking (if known): Please, fill in the following blanks, do not leave blank the function and classification of risk zone:
Fan use: FAN
Zones
Gas
1
Dust
21
2
22
Dangerous substance information (gas and dust fields must be filled):
GAS
Ignition temperature:
Gas state:
ºC Explosion group:
IIA:
IIB:
Corrosive:
IIC:
Toxic:
DUST
Ignition temperature for a dust cloud:
ºC.
Ignition temperature for a 5 mm thick dust layer:
ºC.
Conductive gas:
Type of gas: Non-conductive gas:
Abrasive:
Corrosive:
MOTOR
Motor data (to be filled in case of being known or having special requirements):
Number of starts: per hour:
per day:
EEx-d
EEx-e
EEx-nA
IP-65
WORK ENVIRONMENT DATA
Environment temperature from:
ºC to
ºC Height:
Fan installation: Inlet fan installation:
m
Indoor:
Outdoor:
Outlet fan installation:
(The default is considered 20ºC, 0m, indoor and uncoupled).
143
CONNECTION DIAGRAMS
SINGLE PHASE MOTORS
230V
C
N
C
L
N
L
THREE PHASE MOTORS
230/400V
400/690V
230V
400V
400V
690V
U2
V2
W2
U2
V2
W2
U2
V2
W2
U2
V2
W2
U1
V1
W1
U1
V1
W1
U1
V1
W1
U1
V1
W1
2 SPEEDS MOTORS
400V DAHLANDER (Y,YY)
LOW SPEED
U2
V2
U1
HIGH SPEED
U2
W2
V1
W1
V2
U1
U2
V2
W2
U1
V1
W1
W2
V1
W1
U2
L1
L2
L3
L1
L2
L3
L1
L2
L3
400V SEPARATE WINDINGS
LOW SPEED
HIGH SPEED
2U2 2V2
2W2
1U1 1V1
1W1
2U2
2V2
2U2 2V2
2W2
2W2
1U1 1V1 1W1
L1
144
L2
L3
1U1
1V1
L1
L2
1W1
L3
L1
L2
L3
CONNECTION DIAGRAMS
BD FAN
SINGLE PHASE MOTOR
Compatibility chart BD-REG
L
REG 1,5A
N
REG 3A
REG 5A
REG 10A
BD 7/7 M4 0,15kW
BD 7/7 M6 0,08kW
BD 9/5 M6 0,08kW
BD 9/7 M6 0,15kW
C
black
red
BD 9/9 M4 0,37kW
BD 9/9 M4 0,55kW
thermical
protector
white
BD 9/9 M6 0,15kW
BD 9/9 M6 0,25kW
BD 10/8 M6 0,25kW
THREE PHASE MOTOR
BD 10/10 M4 0,55kW
BD 10/10 M6 0,25kW
BD 10/10 M6 0,37kW
BD 12/9 M6 0,55kW
BD 12/9 M6 0,75kW
BD 12/12 M6 0,55kW
BD 12/12 M6 0,75kW
BD 12/12 M6 1,1kW
Excessive motor current
Bad regulation
Good regulation
Optimum regulation
3 SPEED BD FAN
BD
BD
BD
BD
BD 25/25 M6 1/3 3V
BD 2/28 M6 1/3 3V
blue
green black
L3
L2
19/19
19/19
25/25
25/25
M4
M6
M4
M6
1/5 3V
1/10 3V
1/2 3V
1/5 3V
BD
BD
BD
BD
28/28
28/28
33/33
33/33
M4
M6
M6
M6
3/4 3V
1/2 3V
3/4 3V
1 3V
Ground
yellowgreen red white black blue grey
grey
yellow
Ground
yellow-green
T
switch
L3
L2
L1
L
N
L1
N
L3
T
switch
L
L2
L1
N
L3
L2
L1
N
SB AND SBE FANS
white
black
C
N
L
Ground
145
CONNECTION DIAGRAMS
BT ILF FAN
BT ILF 4, 5, 6
BT ILF 8
T
N2
HV
N3
HV
N2
MV
N1
LV
N
N1
LV
~
L
L
N
~
L
L
BT ILF TIMER
T
N2
HV
N1
LV
N
~
L
L
BT FAN
BT ROOF FAN
black
red
white
C
N
146
L
black
red
N
L
yellow-green
NOTES:
147
NOTES:
148
NOTES:
149
NOTES:
150
NOTES:
151
SALES CONDITIONS
TRANSPORT TERMS:
Ex-Works.
PURCHASING TERMS:
· Only claims before 30 days will be accepted.
· Prices excluding VAT.
· Casals has the right to modify prices and products without previous warning.
RETURNS:
· No returns of customized fans will be accepted. In case of standard fans, returns will only be accepted within the first 3 months after
delivery.
· A written claim form should be filled and agreed by our sales department before any return is accepted.
· After an evaluation, if the return is not justified, the fan will be returned and the client will be charged for the transport costs as well
as 25% depreciation of the fan.
· After an evaluation, if the return is justified, our sales department will arrange collection and credit note, and/or replacement of the
fan.
This price list cancels any previous edition. Valid as of April 15th 2011.
All prices are valid except printing errors.
NOTES:
152

Similar documents

industrial angles

industrial angles AAMHR AAVC AAVG AAVM AAVP AAZA P/R AAZVC AAZVG AAZVM AAZVP AAZZA P/R BC BCD350 BCD500 BCI BD BD 3V BDE BDEM BDR BOX BD BOX BV BOX HB BOX HBF BT

More information