Quaternity - Daikin Comfort
Transcription
Quaternity - Daikin Comfort
Quaternity Up to 26.1 SEER Performance High-Efficiency Ductless System With Dehumidification & Air-Purification Functions Product Features • • • • • • • • • • Inverter Compressor 208/ 230/ 1 Power Supply Cooling Operating Range: 14° - 109° F Heating Operating Range: -4° - 75° F Precharged for up to 32 ft of Liquid Line Indoor Sound Pressure as Low as 26 dB(A) Outdoor Sound Pressures as Low as 46 dB(A) Flash Streamer Technology Advanced dehumidification 3-D Airflow • • • • • • • Comfortable Mode Indoor Unit Quiet Operation Auto Changeover Auto Fan Speed Control Self-Diagnostics with Digital Display Auto Restart after Power Failure Anti-Corrosion Treatment on Heat Exchanger • Max Piping: 32' Length, 26' Height ENERGY STAR® and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency. ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Products that are recognized as the Most Efficient of ENERGY STAR in 2016 prevent greenhouse gas emissions by meeting rigorous energy efficiency performance levels set by the U.S. Environmental Protection Agency. This product meets ENERGY STAR requirements when appropriate coil components are used. Ask your contractor for details. * Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration and some of the additional requirements are not required in California or Quebec. SS-QTRN www.daikincomfort.com 5/16 Supersedes 3/16 Product Specifications Quaternity Premium-Efficiency System Performance Nominal Capacities Cooling Capacity (Rated) Cooling Capacity (Min – Max) Heating Capacity (Rated) Heating Capacity (Min – Max) SEER COP EER HSPF Electrical Data Power Supply Minimum Circuit Amps Maximum Overcurrent Protection Power Consumption - Cooling Power Consumption - Heating BTU/h BTU/h BTU/h BTU/h 9,000 5,300 - 12,300 12,000 4,400 - 18,000 26.1 4.5 15.8 11 12,000 5,300 - 15,700 16,000 4,400 - 19,100 24.2 4.0 14 10.6 15,000 5,300 - 18,000 18,000 4,400 - 21,200 21 4.0 12.9 10 V/Ph/Hz A A W W 208-230/1/60 14.5 15 250 - 900 220 - 1,900 208-230/1/60 14.5 15 260 - 1,300 220 - 2,100 208-230/1/60 14.5 15 260 - 1,930 230 - 2,120 FTXG09HVJU 0.4 420/325/230 438/346/258 42/33/26 42/35/28 Ø 1/4 Ø 3/8 Ø 11/16 FTXG12HVJU 0.5 459/346/240 470/367/272 43/35/27 43/36/29 Ø 1/4 Ø 3/8 Ø 11/16 12 x 35⅟₃₂ x 8⁷⁄₃₂ 31 FTXG15HVJU 0.6 487/371/258 494/392/293 45/37/29 44/38/31 Ø 1/4 Ø 3/8 Ø 11/16 RXG12HVJU 49/48 14° - 109° -4° - 75° 32 26 22⅜ X 31⁹⁄₃₂ x 11⁷⁄₃₂ 99 RXG15HVJU 50/50 14° - 109° -4° - 75° 32 26 Indoor Units: FTXG_HVJU Wall-Mounted Units Model Name Moisture Removal Airflow-Wet (H/M/L) Airflow-Dry (H/M/L) Sound Pressure - Cooling (H/M/L) Sound Pressure – Heating (H/M/L) Liquid (O.D.) Piping Gas (O.D.) Connections Condensate Drain Dimensions (H x W x D) Net Weight gal/h CFM CFM dB(A) dB(A) in. in. in. in. lbs. 31 31 Outdoor Units: RXG_HVJU Heat Pump Model Name Sound Pressure Level - Cooling/Heating Operating Range - Cooling Operating Range - Heating Max. Piping Length Max. Piping Height Dimensions (H x W x D) Net Weight 2 dB(A) °F DB °F DB ft. ft. in. lbs. RXG09HVJU 46/46 14° - 109° -4° - 75° 32 26 99 www.daikincomfort.com 99 SS-QTRN Dimensions — Wall-Mounted Indoor Unit Dimensions — Wall-Mounted Indoor Unit THE MARK (→) SHOWS PIPING DIRECTION REQUIRED SPACE 35-1/16(890) INCLUDING ( MOUNTING PLATE ) 10-13/16(275) 10-3/4(273) 8-1/4(209) GEAR CASE UNIT FIXED SCREWS (INSIDE PANEL) BOTTOM MULTI-COLORED INDICATOR LAMP/ INDOOR UNIT ON/OFF SWITCH TIMER LAMP OPERATING STATE ROOM TEMP. THERMISTOR LIQUID PIPE φ1/4(6.4)Cut COOLING DRY COOLING DRY 7-1/16(180) 20° 15° 30° 60° AIR PURIFYING (INDIVIDUAL OPERATION) HEATING 45° 55° 15° 25° 70° 70° 55° WIRELESS REMOTE CONTROLLER 33(838) 9/16(15) WALL HOLE φ2-9/16(65) HOLE WALL HOLE FOR EMBEDDED PIPING φ2-9/16(65) HOLE 1-7/8(47)~2-3/8(60) 2-5/16(59.5) APPROX.21-9/16(548) APPROX.23-9/16(598) APPROX.25-13/16(655) 45 (ARC447A3) 55° 1-7/16(37) 1 - 3 / 4 (44.5) BLADE ANGLE UP/DOWN (AUTOMATIC) 7-1/8(180.5) 1-1/16(26.8) 9/16(14.5) SIGNAL RECEIVER SIGNAL TRANSMITTER DRAIN HOSE CONNECTING PART I.D. φ9/16(14) O.D. φ11/16(18) GAS PIPE φ3/8(9.5)Cut TERMINAL BLOCK WITH EARTH TERMINAL 2-1/2(63) 1-15/16(50)MIN. (SPACE FOR PERFORMANCE) NAME PLATE 12 (305) FRONT GRILL FIXED SCREWS (INSIDE PANEL) 1-15/16(50)MIN. (SPACE FOR MAINTENANCE) 1-3/4(44.5) RIGHT LEFT 1-3/16(30)MIN. AIR FLOW (INDOOR) REAR (SPACE FOR PERFORMANCE) FTXG09/12/15HVJU ° ° 45 RIGHT/LEFT (AUTOMATIC) STANDARD LOCATIONS OF WALL HOLES 3D061002 Dimensions — Outdoor Unit 1-3/16 (29.5) RXG09/12/15HVJU 22-5/8 (574) 3-3/4 (95.5) 19-7/8 (505) DRAIN OUTLET (I.Dφ5/8 (15.9) HOSE FOR CONNECTION) 4-HOLES FOR ANCHOR BOLTS (M8 OR M10) BRAND NAME LABEL HANDLE 31-5/16 (795) 9/16 (15) OUTDOOR AIR THERMISTOR 2-1/2 (63) GAS STOP VALVE (φ3/8 (9.5) CuT) LIQUID STOP VALVE (φ1/4 (6.4) CuT) SERVICE PORT SS-QTRN 2-15/16 (75) 1/2 (13) 5/8 (15.7) 1-15/16 (50) 1-15/16 (50) www.daikincomfort.com (BASE PITCH) 4-5/8 (118) 7 (178) IN CASE OF REMOVING STOP VALVE COVER 3-15/16 (100) WALL HEIGHT ON AIR OUTLET SIDE = LESS THAN 47-3/16 (1200) 12-1/4 (311) 1-15/16 (50) 5-7/8 (150) 1-15/16 (50) 3-15/16 (100) MINIMUM SPACE FOR AIR PASSAGE 11-1/4 (285) 5-7/8 (150) 11/16 (17) 11-13/16 (300) 13/16 (20) 3-1/8 (79) 22-3/8 (569) NAME PLATE UNIT=INCH (mm) 3D062671A 3 Wiring Diagrams Wiring Diagram — Wall-Mounted Indoor Unit FTXG09/12/15HVJU : PRINTED CIRCUIT BOARD : FLAME GROUND : FUSE : MULTI MONITOR : PILOT LAMP : LIMIT SWITCH FOR PANEL : LIMIT SWITCH FOR STREAMER : FAN MOTOR : SWING MOTOR : THERMISTOR : VARISTOR : CONNECTOR : OPERATION SWITCH : TERMINAL STRIP : SOLENOID VALVE : FERRITE CORE : PROTECTIVE GROUND A3P BLK BLK BLK BLK BLK FIELD WIRING. X1M 1 2 3 Z1C N=4 GRN/ YLW GRN BLK RED WHT 13 LED3 LED2 MULTI MONITOR H3P H2P H1P S56 1 JA A2P BLK BLK BLK BLK BLK BLK BLK BLK BLK BLK BLK BLK BLK A1P S52 - S41 (16PIN) 5 S1 4 1 7 S2C BLK BLK 5 1 S401 S403 HIGH VOLTAGE UNIT S402 A5P BLK BLK STREAMER PART GRN S91 M M M M M1S M2S M3S M1F M M4S S1C R2T A4P 7 RED ORG YLW PNK BLU Y2S Y1S t° S51 1 BLK BLK BLK BLK BLK BLK BLK 1 WHT ORG BRN BLU 4 BLU ORG WHT BLK RED YLW YLW S43 YLW 1 F1U (H250V,T3.15A) + RED HA FG H3 H2 H1 S21 S48 1 TRANSMISSION CIRCUIT R1V 6 BLK BLK BLK BLK BLK BLK 13 S46 S32 BLK HUMIDITY SENSOR 1 RED ORG YLW PNK BLU BLK YLW R1T RED ORG YLW PNK BLU t° 1 WIRELESS REMOTE CONTROLLER SIGNAL TRANSMITTER S57 S1W JA AN ADDRESS SETUP OF REMOTECONTROLLER CN1 1 2 3 SIGNAL RECEIVER S58 JUMPER 6 CAUTION NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS TURNED OFF AND THEN BACK ON AGAIN. outdoor RED ORG YLW PNK BLU A1P~A5P FG F1U H1P H2P, H3P S1C S2C M1F M1S~M4S R1T, R2T R1V S1~S403, CN1 S1W X1M Y1S, Y2S Z1C indoor 3D052768C Wiring Diagram — Outdoor Unit RXG09/12/15HVJU YLW YLW 102°C 1 2 3 L1 L2 L1 1 L2 2 3 X1M BLK WHT RED GRN/ YLW Z1C N=4 Z4C N=2 GRN/YLW YLW Z2C N=3 GRN L1R 1 S45 3 FU3 HL1 30A HN1 V1 S E2 MRM20 MRM10 V2 SA1 E1 PPL FIELD WIRING. ORG indoor HR1 HR2 DB1 ~+ ~_ DB2 +~ FU1 3.15A DB3 +~ IPM1 + _ + _ _ U V W FU2 3.15A _~ PCB1 + + + _ _ MR4 _~ outdoor : MAGNETIC RELAY : COMPRESSOR MOTOR : FAN MOTOR t° M Y1R R1T R2T R3T (OUTDOOR) (DISCHARGE) (CONDENSER) NOTE 1. REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS. : DIODE BRIDGE : FUSE : INTELLIGENT POWER MODULE : LIVE : REACTOR t° t° PCB1 Q1L R1T, R2T, R3T SA1 V1, V2 X1A : PRINTED CIRCUIT BOARD : OVERLOAD PROTECTOR : THERMISTOR : SURGE ARRESTER : VARISTOR : CONNECTOR X1M Y1E Y1R Z1C, Z2C, Z3C, Z4C WHT BLK X1A M Y1E DB1, DB2, DB3 FU1, FU2, FU3 IPM1 L1, L2 L1R MR4, MRM10 MRM20 M1C M1F OL1 OL2 U V W M 1~ M1F Q1L BLU 7 RED YLW S70 123 4 RED YLW BLU 3 WHT BLK S80 RED 1 WHT ORG BRN BLU 6 YLW BLK S90 YLW 1 BLK 6 BLK S20 WHT YLW ORG BLU BRN RED 1 U V Z3C N=3 W M1C : TERMINAL STRIP : ELECTRONIC EXPANSION VALVE COIL : REVERSING SOLENOIDE VALVE COIL : FERRITE CORE : PROTECTIVE GROUND 3D061486 Our continuing commitment to quality products may mean a change in specifications without notice. ©2016 daikin manufacturing company, l.p. • Houston, Texas • Printed in the USA. 4 www.daikincomfort.com SS-QTRN