1 - daikintech.co.uk

Transcription

1 - daikintech.co.uk
• Outdoor Units • R-410A • ARX-GV1B
1
t A i n y U k BS r 1 o AV t o0G i d1- lt4X puR- SRAO
1
1
1
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • ARX-GV1B
2
Specifications
3
2-1 NOMINAL CAPACITY AND
NOMINAL INPUT
For
combination
indoor units +
outdoor units
Indoor Units
Cooling
capacity
Minimum
ARX20GV1B
ARX25GV1B
ARX35GV1B
ATX20GV1B
ATX25GV1B
ATX35GV1B
1
kW
1.3
Btu/h
Maximum
Heating
capacity
Minimum
2.0
2.5
3.2
Btu/h
6,800
8,500
10,900
Kcal/h
1,720
2,150
2,750
2.6
3.0
3.8
Btu/h
8,900
10,200
13,000
Kcal/h
2,240
2,580
3,270
1.3
1.3
1.3
kW
kW
4,400
Kcal/h
Maximum
1,120
kW
2.5
2.8
3.4
Btu/h
8,500
9,600
11,600
Kcal/h
2,150
2,410
2,920
3.5
4.0
4.8
11,600
13,600
16,400
kW
Btu/h
Kcal/h
Power Input
Cooling
Heating
3,010
3,440
4,130
Minimum
kW
0.31
0.31
0.29
Standard
kW
0.55
0.74
0.95
Maximum kW
0.72
1.05
1.30
Minimum
kW
0.25
0.25
0.29
Standard
kW
0.64
0.76
0.91
Maximum kW
0.95
1.11
1.29
For
combination
indoor units +
outdoor units
EER
Nominal
3.62
3.38
3.37
COP
Nominal
3.90
3.68
3.74
Standard
Vivrelec
heating
Standard
heating
Capacity
1.67
1.85
2.22
2.49
2.37
2.39
For
combination
indoor units +
outdoor units
Energy Label
Cooling
2-2
kW
COP
A
Heating
A
Annual energy consumption kWh
TECHNICAL SPECIFICATIONS
Casing
Colour
Dimensions
Unit
Weight
Heat
Exchanger
275
370
475
ARX20GV1B
ARX25GV1B
ARX35GV1B
Ivory White
Height
mm
550
550
550
Width
mm
658
658
658
Depth
mm
275
275
275
Height
mm
616
616
616
Width
mm
788
788
788
Depth
mm
359
359
359
Unit
kg
28
28
30
Packed Unit
kg
31
31
34
mm
670
670
647
1
1
2
1.4
1.4
1.4
24
24
Packing
Dimensions
Length
Nr of Rows
Fin Pitch
mm
Nr of Stages
24
Tube type
Fin
2
1,120
kW
Btu/h
Standard
1.3
4,400
Kcal/h
Standard
1.3
Hi-Xa(7)
Type
Waffle fin
• Split Sky Air • Outdoor Units
2
• Outdoor Units • R-410A • ARX-GV1B
2
2-2
Specifications
TECHNICAL SPECIFICATIONS
Fan
Air Flow Rate
2
Motor
Speed
(nominal)
Fan
Motor
Compressor
Quantity
Motor
1
1
1
29.2
29.2
27.6
Heating
m³/min
(Standard
)
26.2
26.2
24.5
Cooling
cfm
(Standard
)
1,030
1,030
975
Heating
cfm
(Standard
)
927
927
865
1
1
Quantity
1
KFD-280-33-8A
Cooling
(Low)
rpm
720
720
720
Cooling
(High)
rpm
860
860
860
Heating
(Low)
rpm
350
350
350
Heating
(High)
rpm
860
860
860
Output
W
33
33
33
1
1
1
Model
1YC23AEXDA
Type
Operation
Range
Sound Level
(nominal)
W
750
750
750
Min
×CDB
10
10
10
Max
×CDB
46
46
46
Heating
Min
×CWB
-15
-15
-15
Max
×CWB
20
20
20
Cooling
Sound
Power
dBA
60
60
62
Sound
Pressure
(High)
dBA
46
46
48
Sound
Pressure
(High)
dBA
47
47
48
Cooling
Type
Charge
Refrigerant Oil
R-410A
kg
0.74
Type
Charged Volume
3
Hermetically sealed swing compressor
Motor
Output
Heating
Refrigerant
ARX35GV1B
Cooling
m³/min
(Standard
)
Model
Motor
ARX25GV1B
Propeller
Quantity
1
ARX20GV1B
Type
0.74
1.0
FVC50K
l
0.375
• Split Sky Air • Outdoor Units
0.375
0.375
• Outdoor Units • R-410A • ARX-GV1B
2
2-2
Specifications
TECHNICAL SPECIFICATIONS
Piping
connections
Liquid (OD)
Diameter
(OD)
Gas
1
mm
6.35
6.35
6.35
1
1
1
mm
9.52
9.52
9.52
1
1
1
mm
18
18
18
15
15
Maximum m
Additional Refrigerant
Charge
Installation
height
difference
ARX35GV1B
1
Quantity
Diameter
(OD)
Piping Length
ARX25GV1B
1
Quantity
Diameter
(OD)
Drain
ARX20GV1B
Quantity
15
kg/m
m
2
12
12
Heat Insulation
Standard
Accessories
1
0.02 > 10m
Maximum m
Max. internunit level
difference
3
12
Both liquid and gas pipes
Item
Installation manual
Quantity
1
Item
1
1
Drain plug
Quantity
1
Notes
1
1
Nominal cooling capacities are based on: indoor temperature: 27×CDB, 19.0×CWB; outdoor temperature: 35×CDB,
24×CWB, refr.pip.length: 5m
Nominal heating capacities are based Nominal heating capacities are based Nominal heating capacities are based
on: indoor temperature: 20×CDB;
on: indoor temperature:20×CDB,
on: indoor temperature: 20×CDB;
outdoor temperature: 7×CDB,
outdoor temperature:7×CDB,
outdoor temperature: 7×CDB,
6×CWB, refr.pip.length: 5m
6×CWB, refr.pip. length 5m
6×CWB, refr.pip.length: 5m
(horizontal)
Standard Vivrelec heating conditions: indoor temp. 20×CDB/15×CWB; outdoor temp. -7×CDB/-8×CWB; piping lenght
5m.
2-3
ELECTRICAL SPECIFICATIONS
Power Supply
ARX20GV1B
Name
Wiring
connections
ARX35GV1B
V1
Phase
Current
ARX25GV1B
1~
Frequency
Hz
Voltage
V
Nominal
Cooling
running current (A)
(RLA)
Heating
(A)
A
2.52
3.52
4.82
A
2.82
3.32
4.42
Starting current (cooling/
heating)
A
2.7
3.7
5.0
Quantity
3
3
3
For connection Quantity
with indoor
Remark
4
4
4
For Power
Supply
50
50
50
220-230-240
• Split Sky Air • Outdoor Units
(including earth wiring)
4
• Outdoor Units • R-410A • ARX-GV1B
3
Electrical data
Representative unit combination
Indoor unit
Outdoor unit
1
ATX20GV1B
ARX20GV1B
ATX25GV1B
ARX25GV1B
ATX35GV1B
ARX35GV1B
3
Hz-Volts
50-220
50-230
50-240
50-220
50-230
50-240
50-220
50-320
50-240
Power supply
Voltage range
:
:
:
:
:
:
:
:
OFM
IFM
MFA
RHz
RLA
W
FLA
W
Max 50Hz 264V
Min. 50Hz 198V
14.5
16
36
2.2
33
0.17
16
Max 50Hz 264V
Min. 50Hz 198V
14.5
16
48
3.2
33
0.17
16
Max 50Hz 264V
Min. 50Hz 198V
14.5
16
66
4.5
33
0.17
16
SYMBOLS
MCA
MFA
RLA
OFM
IFM
FLA
W
RHz
Comp
MCA
FLA
0.12
0.12
0.12
NOTES
Air flow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input
Rated operating frequency
(A)
(A)
(A)
(A)
(W)
(Hz)
1
2
3
4
RLA is based on the following conditions.
Indoor temp. 27°C DB/19°C WB
Outdoor temp. 35°C DB.
Maximum allowable voltage variation between phases is 2%.
Select wire size based on the larger value of MCA.
Instead of fuse, use circuit breaker.
3D059089
5
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • ARX-GV1B
4
Capacity tables
4-1
Cooling/Heating capacity tables
3
ATX20GV1B + ARX20GV1B
Cooling
50Hz 220-240V
Indoor
EWB EDB
°C
°C
14.0
20
16.0
22
18.0
25
19.0
27
22.0
30
24.0
32
20
SHC
1.71
1.68
1.79
1.91
1.85
1.81
TC
2.05
2.14
2.23
2.28
2.42
2.51
Heating
PI
0.42
0.42
0.43
0.43
0.43
0.43
TC
1.96
2.05
2.14
2.19
2.32
2.42
25
SHC
1.67
1.64
1.75
1.88
1.82
1.78
PI
0.46
0.47
0.47
0.47
0.47
0.47
TC
1.86
1.95
2.05
2.09
2.23
2.32
-10
TC
1.68
1.60
1.56
1.53
1.51
1.48
PI
0.54
0.56
0.56
0.57
0.57
0.58
Outdoor temperature (°C DB)
30
32
SHC
PI
TC
SHC
1.62
0.50
1.83
1.61
1.60
0.51
1.92
1.59
1.71
0.51
2.01
1.70
1.84
0.51
2.06
1.83
1.79
0.51
2.19
1.78
1.76
0.52
2.29
1.74
AFR
50Hz 220-240V
Indoor
EDB
°C
15.0
20.0
22.0
24.0
25.0
27.0
:
:
:
:
:
:
:
Air flow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input
PI
0.52
0.52
0.52
0.53
0.53
0.53
TC
1.77
1.86
1.95
2.00
2.14
2.23
35
SHC
1.58
1.56
1.68
1.80
1.76
1.73
PI
0.54
0.55
0.55
0.55
0.55
0.56
TC
1.68
1.77
1.86
1.91
2.05
2.14
9.1
0.24
40
SHC
1.54
1.52
1.64
1.77
1.73
1.70
PI
0.58
0.59
0.59
0.59
0.59
0.60
1
4
9.4
Outdoor temperature (°C DB)
-5
0
6
TC
PI
TC
PI
TC
PI
1.97
0.57
2.25
0.59
2.59
0.63
1.88
0.58
2.16
0.61
2.50
0.64
1.84
0.59
2.13
0.61
2.47
0.65
1.81
0.59
2.09
0.62
2.43
0.65
1.79
0.60
2.07
0.62
2.41
0.65
1.76
0.60
2.04
0.63
2.38
0.66
10
TC
2.81
2.73
2.69
2.66
2.64
2.61
SYMBOLS
AFR
BF
EWB
EDB
TC
SHC
PI
AFR
BF
PI
0.65
0.66
0.67
0.67
0.68
0.68
NOTES
(m3/mim.)
1
(°C)
(°C)
(kW)
(kW)
(kW)
2
Capacities are based on the following conditions,
(1) Corresponding refrigerant piping length: 5m
(2) Level difference
: 0m
shows nominal (rated) capacities and power input.
3D059080
• Split Sky Air • Outdoor Units
6
• Outdoor Units • R-410A • ARX-GV1B
4
Capacity tables
4-1
Cooling/Heating capacity tables
ATX25GV1B + ARX25GV1B
Cooling
1
4
Indoor
EWB EDB
°C
°C
14.0
20
16.0
22
18.0
25
19.0
27
22.0
30
24.0
32
20
SHC
1.72
1.89
1.98
2.09
2.02
1.96
TC
2.15
2.68
2.79
2.85
3.02
3.14
Heating
PI
0.52
0.57
0.57
0.58
0.58
0.58
TC
2.15
2.56
2.68
2.73
2.91
3.02
25
SHC
1.72
1.83
1.93
2.04
1.97
1.92
PI
0.59
0.63
0.63
0.63
0.64
0.64
TC
2.15
2.44
2.56
2.62
2.79
2.90
-10
TC
1.88
1.79
1.75
1.71
1.69
1.65
PI
0.64
0.66
0.67
0.67
0.68
0.68
Outdoor temperature (°C DB)
30
32
SHC
PI
TC
SHC
1.72
0.66
2.15
1.72
1.78
0.68
2.40
1.76
1.88
0.68
2.51
1.86
1.99
0.69
2.57
1.97
1.93
0.69
2.74
1.91
1.89
0.69
2.86
1.87
AFR
50Hz 220-240V
Indoor
EDB
°C
15.0
20.0
22.0
24.0
25.0
27.0
:
:
:
:
:
:
:
Air flow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input
PI
0.69
0.70
0.71
0.71
0.71
0.72
TC
2.15
2.33
2.44
2.50
2.67
2.79
35
SHC
1.72
1.72
1.83
1.94
1.89
1.85
PI
0.73
0.74
0.74
0.74
0.74
0.75
TC
2.10
2.21
2.33
2.38
2.56
2.67
9.2
0.29
40
SHC
1.69
1.67
1.78
1.90
1.85
1.81
PI
0.79
0.79
0.79
0.79
0.80
0.80
9.7
Outdoor temperature (°C DB)
-5
0
6
TC
PI
TC
PI
TC
PI
2.20
0.67
2.52
0.71
2.90
0.74
2.10
0.69
2.42
0.72
2.80
0.76
2.07
0.70
2.38
0.73
2.76
0.77
2.03
0.70
2.34
0.74
2.72
0.77
2.01
0.71
2.32
0.74
2.70
0.78
1.97
0.72
2.29
0.75
2.66
0.78
10
TC
3.15
3.05
3.01
2.98
2.96
2.92
SYMBOLS
AFR
BF
EWB
EDB
TC
SHC
PI
AFR
BF
50Hz 220-240V
PI
0.77
0.79
0.79
0.80
0.80
0.81
NOTES
(m3/mim.)
1
(°C)
(°C)
(kW)
(kW)
(kW)
2
Capacities are based on the following conditions,
(1) Corresponding refrigerant piping length: 5m
(2) Level difference
: 0m
shows nominal (rated) capacities and power input.
3D059081
7
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • ARX-GV1B
4
Capacity tables
4-1
Cooling/Heating capacity tables
3
ATX35GV1B + ARX35GV1B
Cooling
50Hz 220-240V
Indoor
EWB EDB
°C
°C
14.0
20
16.0
22
18.0
25
19.0
27
22.0
30
24.0
32
20
SHC
1.83
2.11
2.38
2.49
2.40
2.33
TC
2.30
3.07
3.57
3.65
3.87
4.02
Heating
PI
0.69
0.72
0.74
0.74
0.75
0.75
TC
2.30
3.07
3.42
3.50
3.72
3.87
25
SHC
1.83
2.11
2.31
2.43
2.34
2.28
PI
0.79
0.80
0.81
0.81
0.82
0.82
TC
2.30
3.07
3.28
3.35
3.57
3.72
-10
TC
2.29
2.17
2.12
2.08
2.05
2.01
PI
0.77
0.79
0.80
0.81
0.81
0.82
Outdoor temperature (°C DB)
30
32
SHC
PI
TC
SHC
1.83
0.90
2.30
1.83
2.11
0.87
3.07
2.11
2.24
0.88
3.22
2.22
2.36
0.88
3.29
2.34
2.28
0.89
3.51
2.26
2.22
0.89
3.66
2.20
AFR
50Hz 220-240V
Indoor
EDB
°C
15.0
20.0
22.0
24.0
25.0
27.0
:
:
:
:
:
:
:
Air flow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input
PI
0.90
0.90
0.91
0.91
0.91
0.92
TC
2.30
2.98
3.13
3.20
3.42
3.57
35
SHC
1.83
2.07
2.18
2.30
2.22
2.17
PI
0.94
0.94
0.95
0.95
0.96
0.96
TC
2.30
2.83
2.98
3.05
3.27
3.42
9.3
0.25
40
SHC
1.83
2.00
2.11
2.23
2.17
2.12
PI
1.01
1.01
1.02
1.02
1.03
1.03
1
4
10.1
Outdoor temperature (°C DB)
-5
0
6
TC
PI
TC
PI
TC
PI
2.67
0.81
3.06
0.84
3.52
0.89
2.56
0.83
2.94
0.87
3.40
0.91
2.51
0.84
2.89
0.87
3.35
0.92
2.46
0.84
2.85
0.88
3.28
0.93
2.44
0.85
2.82
0.89
3.28
0.93
2.39
0.86
2.77
0.89
3.24
0.94
10
TC
3.82
3.71
3.66
3.61
3.59
3.54
SYMBOLS
AFR
BF
EWB
EDB
TC
SHC
PI
AFR
BF
PI
0.92
0.94
0.95
0.96
0.96
0.97
NOTES
(m3/mim.)
1
(°C)
(°C)
(kW)
(kW)
(kW)
2
Capacities are based on the following conditions,
(1) Corresponding refrigerant piping length: 5m
(2) Level difference
: 0m
shows nominal (rated) capacities and power input.
3D059082
• Split Sky Air • Outdoor Units
8
• Outdoor Units • R-410A • ARX-GV1B
5
Dimensional drawing & centre of gravity
5-1
Dimensional drawing
ARX20-35GV
1
Drain outlet
(I,D Ø15,9.5 hose for connection
with drain joint [Option] )
5
MINIMUM SPACE FOR AIR PASSAGE
Wall height on air outlet side = less than 1200
4-Holes for anchor bolts
(M8 or M10)
Caution label
Brand name label
Handle
Manufacture’s label
Outdoor air thermistor
Model name plate
Up/down (Automatic)
Liquid stop valve
(Ø 6,4 Cut)
Wiring
inlet
Service
port
Cooling
In case of removing stop
valve corner
Gas stop valve
(Ø9.5Cut)
Fan
3D058472
9
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • ARX-GV1B
Piping diagram
3
ARX20-25G
1
6
4D058111B
ARXG20-25G
Outdoor unit
7.0 CuT
Outdoor temperature thermistor
Heat exchanger
9.5 CuT
7.0 CuT
Heat exchanger
thermistor
7.0 CuT
Motor operated valve
6.4 CuT
6.4 CuT
Filter
6.4 CuT
Muffler with
filter
Muffler with
filter
Propeller fan
9.5 CuT
6.4 CuT
9.5 CuT
Discharge pipe
thermistor
Field piping
9.5 CuT
Four way
valve on :
heating
Liquid stop valve
9.5 CuT
6.4 CuT
6
Compressor
Accumulator
Field piping
9.5 CuT
Muffler
(6.4 CuT)
Gas stop valve
(9.5 CuT)
Refrigerant flow
Cooling
Heating
3D058716A
• Split Sky Air • Outdoor Units
10
• Outdoor Units • R-410A • ARX-GV1B
6
Piping diagram
ARX35G
1
6
4D058147B
ARXG35G
Outdoor unit
Heat exchanger
Outdoor temperature thermistor
7.0 CuT
9.5 CuT
7.0 CuT
Heat exchanger
thermistor
7.0 CuT
6.4 CuT
Motor operated valve
6.4 CuT
Muffler with
filter
6.4 CuT
7.0 CuT
Muffler with
filter
9.5 CuT
Propeller fan
4.8 CuT
9.5 CuT
Discharge pipe
thermistor
Field piping
9.5 CuT
Four way
valve on :
heating
Liquid stop valve
6.4 CuT
9.5 CuT
Compressor
Accumulator
9.5 CuT
Muffler
Gas stop valve
(6.4 CuT)
Field piping
(9.5 CuT)
Refrigerant flow
Cooling
Heating
3D058714A
11
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • ARX-GV1B
7
Wiring diagram
7-1
Wiring diagram
3
ARX20-35GV
1
FIELD WIRING
INDOOR
7
OUTDOOR
NOTE
1. Refer to the nameplate for the power requirments.
C5, C6, C119
DB1, DB2, DB3
FU1, FU2, FU3
IPM1, IPM2
L
L1
L1R
M1C
M1F
MR4, MR30, MR10
MRM20
N
: Capacitor
: Diode bridge
: Fuse
: Intelligent power module
: Live
: Coil
: Reactor
: Compressor motor
: Fan motor
: Magnetic relay
: Neutral
IN CASE OF
HEAT PUMP
TYPE .
IN CASE OF
COOLING TYPE
ONLY
(OUTDOOR)
(DISCHARGE)
(CONDENNSOR)
Q1L
PCB1,PCB2
PTC1
S10, S11, S20, S40
S70, S80, S90, HL3
HN3
R1T, R2T, R3T
: Overload protector
: Printed circuit board
: Thermistor PTC
: Connector
: Thermistor
SA1
V1, V2, V3
X1M
Y1E
Y1R
Z1C, Z2C
: Surge arrester
: Varistor
: Terminal strip
: Electronic expansion valve coil
: Electronic expansion valve coil
: Ferrite core
: Protective earth
3D058406B
NOTES
1
2
3
Size: Length 132 x Width 185
Refer to purchasing specification AS(Y)303002, unless otherwise specified.
This drawing was drawn on CAD system.
• Split Sky Air • Outdoor Units
12
• Outdoor Units • R-410A • ARX-GV1B
8
Sound data
8-1
Sound pressure spectrum
ARX20GV
1
8
HEATING
Octave band sound pressure level dB(0dB=0.0002µbar)
COOLING
Octave band sound pressure level dB(0dB=0.0002µbar)
ARX20GV
Approximate
threshold hearing
for continuous
noise
Approximate
threshold hearing
for continuous
noise
Octave band center frequency (Hz)
Octave band center frequency (Hz)
3D059002
3D059002
NOTES
1
2
3
NOTES
Operating conditons:
: 50 Hz 220-240V (H)
Cooling
Measure in anechoic room
Location of microphone
1
2
3
Operating conditons:
: 50 Hz 220-240V (H)
Heating
Measure in anechoic room
Location of microphone
1m
Operation noise differs with operation and ambient conditions.
Operation noise differs with operation and ambient conditions.
ARX25GV
COOLING
Octave band sound pressure level dB(0dB=0.0002µbar)
ARX25GV
4
HEATING
Octave band sound pressure level dB(0dB=0.0002µbar)
4
1m
Approximate
threshold hearing
for continuous
noise
Approximate
threshold hearing
for continuous
noise
Octave band center frequency (Hz)
Octave band center frequency (Hz)
3D059003
3D059003
NOTES
1
2
3
NOTES
Operating conditons:
: 50 Hz 220-240V (H)
Cooling
Measure in anechoic room
Location of microphone
1
2
3
1m
4
13
Operating conditons:
: 50 Hz 220-240V (H)
Heating
Measure in anechoic room
Location of microphone
1m
Operation noise differs with operation and ambient conditions.
• Split Sky Air • Outdoor Units
4
Operation noise differs with operation and ambient conditions.
• Outdoor Units • R-410A • ARX-GV1B
8
Sound data
8-1
Sound pressure spectrum
ARX35GV
3
HEATING
Octave band sound pressure level dB(0dB=0.0002µbar)
COOLING
Octave band sound pressure level dB(0dB=0.0002µbar)
ARX35GV
Approximate
threshold hearing
for continuous
noise
1
8
Approximate
threshold hearing
for continuous
noise
Octave band center frequency (Hz)
Octave band center frequency (Hz)
3D059004
3D059004
NOTES
1
2
3
NOTES
Operating conditons:
: 50 Hz 220-240V (H)
Cooling
Measure in anechoic room
Location of microphone
1
2
3
1m
4
Operating conditons:
: 50 Hz 220-240V (H)
Heating
Measure in anechoic room
Location of microphone
1m
Operation noise differs with operation and ambient conditions.
• Split Sky Air • Outdoor Units
4
Operation noise differs with operation and ambient conditions.
14
• Outdoor Units • R-410A • ARX-GV1B
9
Operation range
ARX20-35GV
Heating
Cooling
1
Continuous operation
Outdoor temp. (°C WB)
Pull-down period
Continuous operation
Outdoor temp. (°C WB)
9
Indoor temp. (°C WB)
Indoor temp. (°C DB)
NOTES
1
The graphs are based on the following conditions.
•
Equivalent piping length 5m
•
Level difference 0m
•
Air flow rate High
3D059075
15
• Split Sky Air • Outdoor Units