• Outdoor Units • R-410A • ARX-GV1B 1 t A i n y U k BS r 1 o AV t o0G i d1- lt4X puR- SRAO 1 1 1 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • ARX-GV1B 2 Specifications 3 2-1 NOMINAL CAPACITY AND NOMINAL INPUT For combination indoor units + outdoor units Indoor Units Cooling capacity Minimum ARX20GV1B ARX25GV1B ARX35GV1B ATX20GV1B ATX25GV1B ATX35GV1B 1 kW 1.3 Btu/h Maximum Heating capacity Minimum 2.0 2.5 3.2 Btu/h 6,800 8,500 10,900 Kcal/h 1,720 2,150 2,750 2.6 3.0 3.8 Btu/h 8,900 10,200 13,000 Kcal/h 2,240 2,580 3,270 1.3 1.3 1.3 kW kW 4,400 Kcal/h Maximum 1,120 kW 2.5 2.8 3.4 Btu/h 8,500 9,600 11,600 Kcal/h 2,150 2,410 2,920 3.5 4.0 4.8 11,600 13,600 16,400 kW Btu/h Kcal/h Power Input Cooling Heating 3,010 3,440 4,130 Minimum kW 0.31 0.31 0.29 Standard kW 0.55 0.74 0.95 Maximum kW 0.72 1.05 1.30 Minimum kW 0.25 0.25 0.29 Standard kW 0.64 0.76 0.91 Maximum kW 0.95 1.11 1.29 For combination indoor units + outdoor units EER Nominal 3.62 3.38 3.37 COP Nominal 3.90 3.68 3.74 Standard Vivrelec heating Standard heating Capacity 1.67 1.85 2.22 2.49 2.37 2.39 For combination indoor units + outdoor units Energy Label Cooling 2-2 kW COP A Heating A Annual energy consumption kWh TECHNICAL SPECIFICATIONS Casing Colour Dimensions Unit Weight Heat Exchanger 275 370 475 ARX20GV1B ARX25GV1B ARX35GV1B Ivory White Height mm 550 550 550 Width mm 658 658 658 Depth mm 275 275 275 Height mm 616 616 616 Width mm 788 788 788 Depth mm 359 359 359 Unit kg 28 28 30 Packed Unit kg 31 31 34 mm 670 670 647 1 1 2 1.4 1.4 1.4 24 24 Packing Dimensions Length Nr of Rows Fin Pitch mm Nr of Stages 24 Tube type Fin 2 1,120 kW Btu/h Standard 1.3 4,400 Kcal/h Standard 1.3 Hi-Xa(7) Type Waffle fin • Split Sky Air • Outdoor Units 2 • Outdoor Units • R-410A • ARX-GV1B 2 2-2 Specifications TECHNICAL SPECIFICATIONS Fan Air Flow Rate 2 Motor Speed (nominal) Fan Motor Compressor Quantity Motor 1 1 1 29.2 29.2 27.6 Heating m³/min (Standard ) 26.2 26.2 24.5 Cooling cfm (Standard ) 1,030 1,030 975 Heating cfm (Standard ) 927 927 865 1 1 Quantity 1 KFD-280-33-8A Cooling (Low) rpm 720 720 720 Cooling (High) rpm 860 860 860 Heating (Low) rpm 350 350 350 Heating (High) rpm 860 860 860 Output W 33 33 33 1 1 1 Model 1YC23AEXDA Type Operation Range Sound Level (nominal) W 750 750 750 Min ×CDB 10 10 10 Max ×CDB 46 46 46 Heating Min ×CWB -15 -15 -15 Max ×CWB 20 20 20 Cooling Sound Power dBA 60 60 62 Sound Pressure (High) dBA 46 46 48 Sound Pressure (High) dBA 47 47 48 Cooling Type Charge Refrigerant Oil R-410A kg 0.74 Type Charged Volume 3 Hermetically sealed swing compressor Motor Output Heating Refrigerant ARX35GV1B Cooling m³/min (Standard ) Model Motor ARX25GV1B Propeller Quantity 1 ARX20GV1B Type 0.74 1.0 FVC50K l 0.375 • Split Sky Air • Outdoor Units 0.375 0.375 • Outdoor Units • R-410A • ARX-GV1B 2 2-2 Specifications TECHNICAL SPECIFICATIONS Piping connections Liquid (OD) Diameter (OD) Gas 1 mm 6.35 6.35 6.35 1 1 1 mm 9.52 9.52 9.52 1 1 1 mm 18 18 18 15 15 Maximum m Additional Refrigerant Charge Installation height difference ARX35GV1B 1 Quantity Diameter (OD) Piping Length ARX25GV1B 1 Quantity Diameter (OD) Drain ARX20GV1B Quantity 15 kg/m m 2 12 12 Heat Insulation Standard Accessories 1 0.02 > 10m Maximum m Max. internunit level difference 3 12 Both liquid and gas pipes Item Installation manual Quantity 1 Item 1 1 Drain plug Quantity 1 Notes 1 1 Nominal cooling capacities are based on: indoor temperature: 27×CDB, 19.0×CWB; outdoor temperature: 35×CDB, 24×CWB, refr.pip.length: 5m Nominal heating capacities are based Nominal heating capacities are based Nominal heating capacities are based on: indoor temperature: 20×CDB; on: indoor temperature:20×CDB, on: indoor temperature: 20×CDB; outdoor temperature: 7×CDB, outdoor temperature:7×CDB, outdoor temperature: 7×CDB, 6×CWB, refr.pip.length: 5m 6×CWB, refr.pip. length 5m 6×CWB, refr.pip.length: 5m (horizontal) Standard Vivrelec heating conditions: indoor temp. 20×CDB/15×CWB; outdoor temp. -7×CDB/-8×CWB; piping lenght 5m. 2-3 ELECTRICAL SPECIFICATIONS Power Supply ARX20GV1B Name Wiring connections ARX35GV1B V1 Phase Current ARX25GV1B 1~ Frequency Hz Voltage V Nominal Cooling running current (A) (RLA) Heating (A) A 2.52 3.52 4.82 A 2.82 3.32 4.42 Starting current (cooling/ heating) A 2.7 3.7 5.0 Quantity 3 3 3 For connection Quantity with indoor Remark 4 4 4 For Power Supply 50 50 50 220-230-240 • Split Sky Air • Outdoor Units (including earth wiring) 4 • Outdoor Units • R-410A • ARX-GV1B 3 Electrical data Representative unit combination Indoor unit Outdoor unit 1 ATX20GV1B ARX20GV1B ATX25GV1B ARX25GV1B ATX35GV1B ARX35GV1B 3 Hz-Volts 50-220 50-230 50-240 50-220 50-230 50-240 50-220 50-320 50-240 Power supply Voltage range : : : : : : : : OFM IFM MFA RHz RLA W FLA W Max 50Hz 264V Min. 50Hz 198V 14.5 16 36 2.2 33 0.17 16 Max 50Hz 264V Min. 50Hz 198V 14.5 16 48 3.2 33 0.17 16 Max 50Hz 264V Min. 50Hz 198V 14.5 16 66 4.5 33 0.17 16 SYMBOLS MCA MFA RLA OFM IFM FLA W RHz Comp MCA FLA 0.12 0.12 0.12 NOTES Air flow rate Bypass factor Entering wet bulb temp. Entering dry bulb temp. Total capacity Sensible heat capacity Power input Rated operating frequency (A) (A) (A) (A) (W) (Hz) 1 2 3 4 RLA is based on the following conditions. Indoor temp. 27°C DB/19°C WB Outdoor temp. 35°C DB. Maximum allowable voltage variation between phases is 2%. Select wire size based on the larger value of MCA. Instead of fuse, use circuit breaker. 3D059089 5 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • ARX-GV1B 4 Capacity tables 4-1 Cooling/Heating capacity tables 3 ATX20GV1B + ARX20GV1B Cooling 50Hz 220-240V Indoor EWB EDB °C °C 14.0 20 16.0 22 18.0 25 19.0 27 22.0 30 24.0 32 20 SHC 1.71 1.68 1.79 1.91 1.85 1.81 TC 2.05 2.14 2.23 2.28 2.42 2.51 Heating PI 0.42 0.42 0.43 0.43 0.43 0.43 TC 1.96 2.05 2.14 2.19 2.32 2.42 25 SHC 1.67 1.64 1.75 1.88 1.82 1.78 PI 0.46 0.47 0.47 0.47 0.47 0.47 TC 1.86 1.95 2.05 2.09 2.23 2.32 -10 TC 1.68 1.60 1.56 1.53 1.51 1.48 PI 0.54 0.56 0.56 0.57 0.57 0.58 Outdoor temperature (°C DB) 30 32 SHC PI TC SHC 1.62 0.50 1.83 1.61 1.60 0.51 1.92 1.59 1.71 0.51 2.01 1.70 1.84 0.51 2.06 1.83 1.79 0.51 2.19 1.78 1.76 0.52 2.29 1.74 AFR 50Hz 220-240V Indoor EDB °C 15.0 20.0 22.0 24.0 25.0 27.0 : : : : : : : Air flow rate Bypass factor Entering wet bulb temp. Entering dry bulb temp. Total capacity Sensible heat capacity Power input PI 0.52 0.52 0.52 0.53 0.53 0.53 TC 1.77 1.86 1.95 2.00 2.14 2.23 35 SHC 1.58 1.56 1.68 1.80 1.76 1.73 PI 0.54 0.55 0.55 0.55 0.55 0.56 TC 1.68 1.77 1.86 1.91 2.05 2.14 9.1 0.24 40 SHC 1.54 1.52 1.64 1.77 1.73 1.70 PI 0.58 0.59 0.59 0.59 0.59 0.60 1 4 9.4 Outdoor temperature (°C DB) -5 0 6 TC PI TC PI TC PI 1.97 0.57 2.25 0.59 2.59 0.63 1.88 0.58 2.16 0.61 2.50 0.64 1.84 0.59 2.13 0.61 2.47 0.65 1.81 0.59 2.09 0.62 2.43 0.65 1.79 0.60 2.07 0.62 2.41 0.65 1.76 0.60 2.04 0.63 2.38 0.66 10 TC 2.81 2.73 2.69 2.66 2.64 2.61 SYMBOLS AFR BF EWB EDB TC SHC PI AFR BF PI 0.65 0.66 0.67 0.67 0.68 0.68 NOTES (m3/mim.) 1 (°C) (°C) (kW) (kW) (kW) 2 Capacities are based on the following conditions, (1) Corresponding refrigerant piping length: 5m (2) Level difference : 0m shows nominal (rated) capacities and power input. 3D059080 • Split Sky Air • Outdoor Units 6 • Outdoor Units • R-410A • ARX-GV1B 4 Capacity tables 4-1 Cooling/Heating capacity tables ATX25GV1B + ARX25GV1B Cooling 1 4 Indoor EWB EDB °C °C 14.0 20 16.0 22 18.0 25 19.0 27 22.0 30 24.0 32 20 SHC 1.72 1.89 1.98 2.09 2.02 1.96 TC 2.15 2.68 2.79 2.85 3.02 3.14 Heating PI 0.52 0.57 0.57 0.58 0.58 0.58 TC 2.15 2.56 2.68 2.73 2.91 3.02 25 SHC 1.72 1.83 1.93 2.04 1.97 1.92 PI 0.59 0.63 0.63 0.63 0.64 0.64 TC 2.15 2.44 2.56 2.62 2.79 2.90 -10 TC 1.88 1.79 1.75 1.71 1.69 1.65 PI 0.64 0.66 0.67 0.67 0.68 0.68 Outdoor temperature (°C DB) 30 32 SHC PI TC SHC 1.72 0.66 2.15 1.72 1.78 0.68 2.40 1.76 1.88 0.68 2.51 1.86 1.99 0.69 2.57 1.97 1.93 0.69 2.74 1.91 1.89 0.69 2.86 1.87 AFR 50Hz 220-240V Indoor EDB °C 15.0 20.0 22.0 24.0 25.0 27.0 : : : : : : : Air flow rate Bypass factor Entering wet bulb temp. Entering dry bulb temp. Total capacity Sensible heat capacity Power input PI 0.69 0.70 0.71 0.71 0.71 0.72 TC 2.15 2.33 2.44 2.50 2.67 2.79 35 SHC 1.72 1.72 1.83 1.94 1.89 1.85 PI 0.73 0.74 0.74 0.74 0.74 0.75 TC 2.10 2.21 2.33 2.38 2.56 2.67 9.2 0.29 40 SHC 1.69 1.67 1.78 1.90 1.85 1.81 PI 0.79 0.79 0.79 0.79 0.80 0.80 9.7 Outdoor temperature (°C DB) -5 0 6 TC PI TC PI TC PI 2.20 0.67 2.52 0.71 2.90 0.74 2.10 0.69 2.42 0.72 2.80 0.76 2.07 0.70 2.38 0.73 2.76 0.77 2.03 0.70 2.34 0.74 2.72 0.77 2.01 0.71 2.32 0.74 2.70 0.78 1.97 0.72 2.29 0.75 2.66 0.78 10 TC 3.15 3.05 3.01 2.98 2.96 2.92 SYMBOLS AFR BF EWB EDB TC SHC PI AFR BF 50Hz 220-240V PI 0.77 0.79 0.79 0.80 0.80 0.81 NOTES (m3/mim.) 1 (°C) (°C) (kW) (kW) (kW) 2 Capacities are based on the following conditions, (1) Corresponding refrigerant piping length: 5m (2) Level difference : 0m shows nominal (rated) capacities and power input. 3D059081 7 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • ARX-GV1B 4 Capacity tables 4-1 Cooling/Heating capacity tables 3 ATX35GV1B + ARX35GV1B Cooling 50Hz 220-240V Indoor EWB EDB °C °C 14.0 20 16.0 22 18.0 25 19.0 27 22.0 30 24.0 32 20 SHC 1.83 2.11 2.38 2.49 2.40 2.33 TC 2.30 3.07 3.57 3.65 3.87 4.02 Heating PI 0.69 0.72 0.74 0.74 0.75 0.75 TC 2.30 3.07 3.42 3.50 3.72 3.87 25 SHC 1.83 2.11 2.31 2.43 2.34 2.28 PI 0.79 0.80 0.81 0.81 0.82 0.82 TC 2.30 3.07 3.28 3.35 3.57 3.72 -10 TC 2.29 2.17 2.12 2.08 2.05 2.01 PI 0.77 0.79 0.80 0.81 0.81 0.82 Outdoor temperature (°C DB) 30 32 SHC PI TC SHC 1.83 0.90 2.30 1.83 2.11 0.87 3.07 2.11 2.24 0.88 3.22 2.22 2.36 0.88 3.29 2.34 2.28 0.89 3.51 2.26 2.22 0.89 3.66 2.20 AFR 50Hz 220-240V Indoor EDB °C 15.0 20.0 22.0 24.0 25.0 27.0 : : : : : : : Air flow rate Bypass factor Entering wet bulb temp. Entering dry bulb temp. Total capacity Sensible heat capacity Power input PI 0.90 0.90 0.91 0.91 0.91 0.92 TC 2.30 2.98 3.13 3.20 3.42 3.57 35 SHC 1.83 2.07 2.18 2.30 2.22 2.17 PI 0.94 0.94 0.95 0.95 0.96 0.96 TC 2.30 2.83 2.98 3.05 3.27 3.42 9.3 0.25 40 SHC 1.83 2.00 2.11 2.23 2.17 2.12 PI 1.01 1.01 1.02 1.02 1.03 1.03 1 4 10.1 Outdoor temperature (°C DB) -5 0 6 TC PI TC PI TC PI 2.67 0.81 3.06 0.84 3.52 0.89 2.56 0.83 2.94 0.87 3.40 0.91 2.51 0.84 2.89 0.87 3.35 0.92 2.46 0.84 2.85 0.88 3.28 0.93 2.44 0.85 2.82 0.89 3.28 0.93 2.39 0.86 2.77 0.89 3.24 0.94 10 TC 3.82 3.71 3.66 3.61 3.59 3.54 SYMBOLS AFR BF EWB EDB TC SHC PI AFR BF PI 0.92 0.94 0.95 0.96 0.96 0.97 NOTES (m3/mim.) 1 (°C) (°C) (kW) (kW) (kW) 2 Capacities are based on the following conditions, (1) Corresponding refrigerant piping length: 5m (2) Level difference : 0m shows nominal (rated) capacities and power input. 3D059082 • Split Sky Air • Outdoor Units 8 • Outdoor Units • R-410A • ARX-GV1B 5 Dimensional drawing & centre of gravity 5-1 Dimensional drawing ARX20-35GV 1 Drain outlet (I,D Ø15,9.5 hose for connection with drain joint [Option] ) 5 MINIMUM SPACE FOR AIR PASSAGE Wall height on air outlet side = less than 1200 4-Holes for anchor bolts (M8 or M10) Caution label Brand name label Handle Manufacture’s label Outdoor air thermistor Model name plate Up/down (Automatic) Liquid stop valve (Ø 6,4 Cut) Wiring inlet Service port Cooling In case of removing stop valve corner Gas stop valve (Ø9.5Cut) Fan 3D058472 9 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • ARX-GV1B Piping diagram 3 ARX20-25G 1 6 4D058111B ARXG20-25G Outdoor unit 7.0 CuT Outdoor temperature thermistor Heat exchanger 9.5 CuT 7.0 CuT Heat exchanger thermistor 7.0 CuT Motor operated valve 6.4 CuT 6.4 CuT Filter 6.4 CuT Muffler with filter Muffler with filter Propeller fan 9.5 CuT 6.4 CuT 9.5 CuT Discharge pipe thermistor Field piping 9.5 CuT Four way valve on : heating Liquid stop valve 9.5 CuT 6.4 CuT 6 Compressor Accumulator Field piping 9.5 CuT Muffler (6.4 CuT) Gas stop valve (9.5 CuT) Refrigerant flow Cooling Heating 3D058716A • Split Sky Air • Outdoor Units 10 • Outdoor Units • R-410A • ARX-GV1B 6 Piping diagram ARX35G 1 6 4D058147B ARXG35G Outdoor unit Heat exchanger Outdoor temperature thermistor 7.0 CuT 9.5 CuT 7.0 CuT Heat exchanger thermistor 7.0 CuT 6.4 CuT Motor operated valve 6.4 CuT Muffler with filter 6.4 CuT 7.0 CuT Muffler with filter 9.5 CuT Propeller fan 4.8 CuT 9.5 CuT Discharge pipe thermistor Field piping 9.5 CuT Four way valve on : heating Liquid stop valve 6.4 CuT 9.5 CuT Compressor Accumulator 9.5 CuT Muffler Gas stop valve (6.4 CuT) Field piping (9.5 CuT) Refrigerant flow Cooling Heating 3D058714A 11 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • ARX-GV1B 7 Wiring diagram 7-1 Wiring diagram 3 ARX20-35GV 1 FIELD WIRING INDOOR 7 OUTDOOR NOTE 1. Refer to the nameplate for the power requirments. C5, C6, C119 DB1, DB2, DB3 FU1, FU2, FU3 IPM1, IPM2 L L1 L1R M1C M1F MR4, MR30, MR10 MRM20 N : Capacitor : Diode bridge : Fuse : Intelligent power module : Live : Coil : Reactor : Compressor motor : Fan motor : Magnetic relay : Neutral IN CASE OF HEAT PUMP TYPE . IN CASE OF COOLING TYPE ONLY (OUTDOOR) (DISCHARGE) (CONDENNSOR) Q1L PCB1,PCB2 PTC1 S10, S11, S20, S40 S70, S80, S90, HL3 HN3 R1T, R2T, R3T : Overload protector : Printed circuit board : Thermistor PTC : Connector : Thermistor SA1 V1, V2, V3 X1M Y1E Y1R Z1C, Z2C : Surge arrester : Varistor : Terminal strip : Electronic expansion valve coil : Electronic expansion valve coil : Ferrite core : Protective earth 3D058406B NOTES 1 2 3 Size: Length 132 x Width 185 Refer to purchasing specification AS(Y)303002, unless otherwise specified. This drawing was drawn on CAD system. • Split Sky Air • Outdoor Units 12 • Outdoor Units • R-410A • ARX-GV1B 8 Sound data 8-1 Sound pressure spectrum ARX20GV 1 8 HEATING Octave band sound pressure level dB(0dB=0.0002µbar) COOLING Octave band sound pressure level dB(0dB=0.0002µbar) ARX20GV Approximate threshold hearing for continuous noise Approximate threshold hearing for continuous noise Octave band center frequency (Hz) Octave band center frequency (Hz) 3D059002 3D059002 NOTES 1 2 3 NOTES Operating conditons: : 50 Hz 220-240V (H) Cooling Measure in anechoic room Location of microphone 1 2 3 Operating conditons: : 50 Hz 220-240V (H) Heating Measure in anechoic room Location of microphone 1m Operation noise differs with operation and ambient conditions. Operation noise differs with operation and ambient conditions. ARX25GV COOLING Octave band sound pressure level dB(0dB=0.0002µbar) ARX25GV 4 HEATING Octave band sound pressure level dB(0dB=0.0002µbar) 4 1m Approximate threshold hearing for continuous noise Approximate threshold hearing for continuous noise Octave band center frequency (Hz) Octave band center frequency (Hz) 3D059003 3D059003 NOTES 1 2 3 NOTES Operating conditons: : 50 Hz 220-240V (H) Cooling Measure in anechoic room Location of microphone 1 2 3 1m 4 13 Operating conditons: : 50 Hz 220-240V (H) Heating Measure in anechoic room Location of microphone 1m Operation noise differs with operation and ambient conditions. • Split Sky Air • Outdoor Units 4 Operation noise differs with operation and ambient conditions. • Outdoor Units • R-410A • ARX-GV1B 8 Sound data 8-1 Sound pressure spectrum ARX35GV 3 HEATING Octave band sound pressure level dB(0dB=0.0002µbar) COOLING Octave band sound pressure level dB(0dB=0.0002µbar) ARX35GV Approximate threshold hearing for continuous noise 1 8 Approximate threshold hearing for continuous noise Octave band center frequency (Hz) Octave band center frequency (Hz) 3D059004 3D059004 NOTES 1 2 3 NOTES Operating conditons: : 50 Hz 220-240V (H) Cooling Measure in anechoic room Location of microphone 1 2 3 1m 4 Operating conditons: : 50 Hz 220-240V (H) Heating Measure in anechoic room Location of microphone 1m Operation noise differs with operation and ambient conditions. • Split Sky Air • Outdoor Units 4 Operation noise differs with operation and ambient conditions. 14 • Outdoor Units • R-410A • ARX-GV1B 9 Operation range ARX20-35GV Heating Cooling 1 Continuous operation Outdoor temp. (°C WB) Pull-down period Continuous operation Outdoor temp. (°C WB) 9 Indoor temp. (°C WB) Indoor temp. (°C DB) NOTES 1 The graphs are based on the following conditions. • Equivalent piping length 5m • Level difference 0m • Air flow rate High 3D059075 15 • Split Sky Air • Outdoor Units