Analog and Control Wiring and Adjustment Manual For Gyro Tech
Transcription
Analog and Control Wiring and Adjustment Manual For Gyro Tech
NABCO ENTRANCES Inc. S82 W18717 Gemini Drive Muskego, WI 53150 Phone: 877-622-2694 Fax: 888-679-3319 Technical Assistance: 866-622-8325 www.nabcoentrances.com Email: [email protected] Analog Control Wiring & Adjustment Manual for Gyro Tech Swing Door Operators Part Number 15-10745 Rev 8-13-09 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems CAUTION Read these safety practices before installing, operating or servicing the automatic door. Failure to follow these practices may result in serious consequences. Read, study and understand the operating instructions contained in or referenced in this manual before operating. If you do not understand the instruction, ask the installing qualified technician to teach you how to use the door. This manual and the owners’ manual must be given to and retained by the purchasing facility or end user. If the door appears broken or does not seem to work correctly, it should be immediately removed from service and a qualified service technician contacted for corrective action. Disconnect power at the fused disconnect during all electrical or mechanical service. When uncertain whether power supply is disconnected, always verify using a voltmeter. All electrical troubleshooting or service must be performed by qualified electrical technicians and must comply with all applicable governing agency codes. It is the responsibility of the installing door technician to install all warning and instructional labels in accordance with the applicable ANSI standard. It is the responsibility of the purchasing facility or end user to keep warning and instructional labels and literature legible, intact and with the door. Replacement labels and literature may be obtained from local NABCO ENTRANCES INC. authorized distributors. If the name of the local distributor is unknown, contact NABCO ENTRANCES INC. at (877-6222694) for assistance. Do not place finger or uninsulated tools inside the electrical control box. Touching wires or other parts inside the enclosure may cause electrical shock, serious injury or death. All adjustments should be made with a small screwdriver. DO NOT use a pencil. The ground wire from the Magnum 120 VAC harness and the ground wire from the 120 VAC “in” line must be attached to the ground screw which is located in the header. Final installation must conform to current versions of ANSI 156.19 for Low Energy swingers or ANSI 156.10 for Full Automatic Installations. Page 2 www.NabcoEntrances.com 8-13-09 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems Table of Contents To The Installer Page 4 Overview Page 4 Specifications Page 4 Analog Control Components Page 5 Wiring Connectors Page 6 Door Positions Page 6 Terminology Page 6 Adjustments Page 6 Micro switch Adjustments Page 7 Wiring for Rocker switch Page 7 Wiring for Panic Break–out Page 8 Required Wiring Harnesses Page 9 Section A - Sample Wiring Diagrams for GT-300, GT-400 Full Automatic Installations Page 10 Figure 7 - General Wiring - GT-300/400 Single Outswing Page 11 Figure 8 - General Wiring - GT-300/400 Single Inswing Page 12 Figure 9 - General Wiring – GT-300/400 Pair Outswing Page 13 Figure 10 - General Wiring – GT-300/400 Pair Inswing Page 14 Section B - Sample Wiring Diagrams for GT-500 Low Energy Installations Page 15 Figure 11 - General Wiring - GT-500 Single Outswing Page 16 Figure 12 - General Wiring - GT-500 Single Inswing Page 17 Figure 13 - General Wiring – GT-500 Pair Outswing Page 18 Figure 14 - General Wiring – GT-500 Pair Inswing Page 19 Figure 15 - GT-500 with Electric Lock & Sequencer Page 20 Troubleshooting Page 21 Troubleshooting Page 22 Page 3 www.NabcoEntrances.com 8-13-09 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems To The Installer The purpose of this manual is to familiarize the purchaser with the proper installation and operation of this system. It is essential that this equipment be properly installed and operational before the door is used by the public. It is the purchaser’s responsibility to inspect the operation of the entrance system to be sure it complies with any applicable standards. In the United States, ANSI Standard 156.19 usually covers this type of door. Other local standards or codes may apply. Use them in addition to the ANSI Standard. Instruct the building owners/operator on the essentials of the operation of the door and this device. The owner should follow these instructions to determine whether the door is operating properly and should immediately call for service if there is any malfunction. All installation changes and adjustments must be made by qualified, NABCO trained technicians. Overview Some features of the Analog Control: A. D. E. F. G. One safety input with slide switch to select safety modes: 1. Standard Safe - Safety is ignored during opening cycle only 2. Swing Safe - Safety is never ignored 3. Slide - DO NOT USE Push-N-Go module available as an option (GT-500 Standard Mode only) Open speed slide switch Check speed slide switch 24 VAC 0.25 Amp output for auxiliary devices Specifications: Power Input 120 VAC (±10%) AC 50-60 Hz, 5 Amps Available Output for Accessories 0.25 Amps 24 Volts AC Available Wire Size for Incoming Power 14 AWG Fuses 1 x 120 VAC, BUSS GLH-8 Thermo-Couple Automatic cutoff of motor if overheated Activation Hold Time Adjustable 0-60 seconds (with optional time delay module) Page 4 www.NabcoEntrances.com 8-13-09 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems 3 2 1 4 5 6 7 Part # 41-1512 41-2342 41-2208 41-3429 Type Optional Speed Optional Speed Standard Mode Standard Mode Country US Canada US Canada Figure 1 Analog Control Components ITEM 9 8 10 12 11 13 DESCRIPTION USE NOTES: 1 OPEN Speed Switch Vary the opening speed Fast position toward center of control 2 120 VAC Connector Supply 120 VAC to control and equipment 3 Fuse Main fuse for control 4 Activate Relay Relay responsible for switching voltage to motor 5 Operator Switch Harness Connector Used to connect the motor and operator micro switch circuit to the control 6 Closing Resistor Governs closing speed of door. Resistor Value of resistor governs closing speed. located on terminals 1 &3 of terminal block. Higher value speeds up door. Lower value Terminal 1 being closest to edge of control. slows door down. 7 Latch Resistor Governs latch speed of door. Resistor located on terminals 2 &4 of terminal block. Terminal 1 being closest to edge of control. 8 Check Speed Switch Vary the back check speed Fast position toward center of control 9 Mat Harness Connector Interfaces the Activation, Safety and 24 VAC signals to the control Black: Activation Signal Red: Common to Signal and 24 VAC White: Safety Signal Orange: 24 VAC 10 Safety Relay Relay responsible for switching the Safety circuit BUSS GLH-8 Model 850 Lockout (when used) also connects here 11 Safety Selector Switch Slide switch to select two safety modes 1. Standard Safe - Safety is ignored during opening cycle only 2. Swing Safe - Continuous Safety 3. Slide - DO NOT USE 12 Motor Protector Relay Relay responsible for switch motor between high OPEN speed voltage and low CHECK speed voltage This relay is not used with the GT-500 Standard Mode system. The relay is removed and a jumper is installed in its place. 13 Soft Start Capacitor Connectors Used with GT300/400 and GT500 Optional Speed Units. Not used on GT-500 Standard Mode Control. Leads should be connected together if a soft start capacitor is not used. Otherwise door will not open. Page 5 www.NabcoEntrances.com 8-13-09 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems Wiring Connectors: Refer to Figure 1. There are three connectors located on the control board. These are: 1. 120 VAC Connector This is a three-pin connector with a mating connector installed. The 120 VAC Hot, Neutral and Ground connect to this plug 2. Activation Connector VAC This is a four-pin connector with a mating connector installed. The function of the wires on this connector are as follows: Black: Activation - Shorting this wire to Red common will open the door. Red: Common White: Safety - Shorting this wire to Red common will safety the door. Orange: 24 VAC - Connecting a load between this wire and Red common will apply 24 to the load. Figure 2 - Door Positions Full Open Back chec k M ain sp d ee Latch Check Closed DN0035 Terminology: Back Check – This takes place from about the last 10º of sweep to the full open position. Closing Speed – How fast the door moves from fully open to the final 10º before fully closed. Latch Check–This takes place from about the last 10º of sweep to the full closed position. Opening Speed – How fast the door opens from fully closed to approximately 80º open. Time Delay Activation Signal – When the door is activated via a push plate, a mat, a sensor, etc., this option determines how long the door will stay open. It is adjustable up to 60 seconds. Adjustments: There are three slide switch adjustments on the Analog Control Board. Refer to Items 1, 8, and 11 in Figure 1. There are two switches that govern OPEN and CHECK speeds and one that controls when the safety signal on the White wire on the Mat Harness is acknowledged. Notes: The amount of energy stored in the door and imparted to an object on impact is determined by both the weight and speed of the door. NABCO ENTRANCES INC. recommends setting opening and closing speeds as slow as owners will accept, AND below the maximums stated by ANSI. The settings on the controller will vary slightly as the voltage supplied to the unit varies due to fluctuations in building and electrical supply loads. To allow for variations, the manufacturer recommends adding 1 second to ANSI’s minimum opening or closing times. Use a stopwatch for assistance. Page 6 www.NabcoEntrances.com 8-13-09 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems Micro switch Adjustments: This section details the installation and adjustments of the Analog Control in a GT-300 and GT-400 swing door units. Step 1: Install all components as per the applicable hardware installation manual. Step 2: Connect all wiring and harnesses as per the following wiring diagrams as they pertain to wiring and adjustments for GT-300, GT-400, GT-500, and GT-600 Operators. Back Check and Latch Micro Switches: The operators used with the GT-300, GT-400 and GT-500’s provide the necessary latch check and back check limit switches the Analog control requires for correct operation. These switches are mounted on the top of the operator assembly as illustrated in the Figure # 3 below. Wiring for Rocker switch: Rocker Switch (part # 10-3528) is available. Connect the red wire to the black on the Mat Harness connector, the white wire to Red common on the Mat Harness connector and the black wire to the normally open contact of the activation device. Refer to FIGURE 3 - MICRO SWITCH CONFIGURATIONS LATCH CHECK SWITCH BACKCHECK ADJUSTMENT SET SCREW BROWN ORANGE LEFT HAND OPERATOR SHOWN IN UNWOUND POSITION BLUE PANIC BACK CHECK SWITCH BREAKOUT SWITCH BACK CHECK SWITCH PANIC BREAKOUT SWITCH WHITE YELLOW YELLOW WHITE BLUE RIGHT HAND OPERATOR SHOWN IN UNWOUND POSITION ORANGE BACKCHECK ADJUSTMENT SET SCREW Page 7 DN 0146 LATCH CHECK SWITCH BROWN www.NabcoEntrances.com 8-13-09 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems Wiring for Panic Break–out: When the unit has a Break-out feature, the panic breakout circuit must be connected to shut down the system when the door is broken out in the opposite direction. This is done by opening the Red common circuit to the activation devices. Please refer to the following procedure. Panic Latch must be installed. When installing the panic latch, the panic latch is installed so that the “ ← EXT” arrow points to Enterior side of the building. This makes the switch open when the door is broken out. See Figure 4 below. Plug the Red wire from the Mat Harness into the mating connector of the panic breakout switch. Plug the other connector on the panic breakout switch into the mating connector on one of the red wires going to the micro switch on the top of the operator. Connect the other Red wire from the micro switch to the various necessary points required for the common wire. Refer to the following diagrams. A b. FIGURE 4 PANIC LATCH EXT Exterior Side Interior Side DN0060 FIGURE 5 BREAKOUT CIRCUIT WIRING DIAGRAM Breakout Limit Switch N.C. (Red & Red) Gyro Tech Analog Control Rly Operator Assembly Rly Rly 4 3 2 1 Red Operator Switch Harness Red Mat Harness Part # 24-0535 Org Wht Red (24 VAC) (Safety) Black Red To N.O. Contacts of Activation Devices To COM Contacts of Activation Devices Page 8 Red Panic Breakout Latch OHC Units Part # 11-0930 CU Units Part # 11-0941 www.NabcoEntrances.com DN 0147 8-13-09 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems Required Wiring Harnesses: See below for an illustration of some of the wiring harnesses that are necessary to complete a typical installation. 14" Extension Harness Part # 22-0083 Operator Switch Harness Part #: 22-0570 Three Switch Operator 22-4508 Two Switch Operator Soft Start Capacitor Harness (Sim Pair) Part # 22-2174 "Y" harness Simultaneous Pair Part # 22-0087 Power Harness Part # 22-0779 Gyro Tech Analog Control Part #: 41-1512 GT-400 Spring Close - USA 41-2208 GT-500 Spring Close Slow Mode - USA 41-2342 GT-400 Spring Close - Canada 41-3429 GT-500 Spring Close Slow Mode - Canada Soft Start Capacitor Harness (Single) Part # 22-2066 Mat Harness Part # 24-0535 Orange Wht Red Black DN 0158 FIGURE 6 - WIRING HARNESSES FOR MAGNUM IV Page 9 www.NabcoEntrances.com 8-13-09 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems Section A Sample Wiring Diagrams for GT-300, GT-400 Full Automatic Installations Page 11 Figure 6 - General Wiring - GT-300/400 Single Outswing Page 12 Figure 7 - General Wiring - GT-300/400 Single Inswing Page 13 Figure 8 - General Wiring – GT-300/400 Pair Outswing Page 14 Figure 9 - General Wiring – GT-300/400 Pair Inswing Page 10 www.NabcoEntrances.com 8-13-09 Page 11 www.NabcoEntrances.com Green Black Red Relay - COM 24 VAC 24 VAC DN 0149 Blk Red Wht Potentiometer is located on side of case Mat Harness Part # 24-0535 Blue (not used) Soft Start Capacitor (refer to Note 2) Time Delay PC-6 Blk Lockout Power LED's Relay Lock out Red Org Org 24 VAC To Motor Leads 4 3 2 1 Brown White Red N.O. Operator Assembly Breakout Limit Switch N.C. (Red & Red) SAFETY BEAMS (IF USED) Notes: 1. If activation device is capable of holding a switch closure across Red and Black for the required door open time period, time delay (PN 24-3425) is not required. If a momentary activation device such as a wall swtich is used, time delay must be used as shown. 2. Soft Start Capacitors (not used with GT-500 SM Control) GT300/400 - Part # 11-2067 GT-500 Optional Speed Mode -Part # 11-3536 3. Separate transformer required for PC6 lockout and Acusensors. 4. A wire connection is indicated by a black circle Operator Switch Harness CONTACTS GREY VIOLET Blue Not Used Red Operator Switch Harness Part # 22-0570 Figure 7 - General Wiring - GT-300/400 Single Outswing Presence Acusensor 1B Sensor White Relay - NO Approach Acusensor 1B Sensor 24 VAC Red Green Black 24 VAC White Relay - COM Blk Red Wht Relay - NO RS-12 Rocker Switch Part # 10-3528 Model 2200 Time Delay Prt # 243425 Gyro Tech Analog Control Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems 8-13-09 Page 12 Blk Red Wht www.NabcoEntrances.com Blk DN 0150 Red Wht Potentiometer is located on side of case Mat Harness Part # 24-0535 Blue (not used) Soft Start Capacitor (refer to Note 2) Blk Time Delay Lockout Power LED's PN 14-11807 PC-6 Lock out Relay Red Org Org 24 VAC To Motor Leads 4 3 2 1 Brown N.O. CONTACTS GREY VIOLET Blue White Red Red Red Operator Assembly Breakout Limit Switch N.C. (Red & Red) Panic Breakout Latch OHC Units Part # 11-0930 CU Units Part # 11-0941 Red SAFETY BEAMS (IF USED) Notes: 1. If activation device is capable of holding a switch closure across Red and Black for the required door open time period, time delay (PN 24-3425) is not required. If a momentary activation device such as a wall swtich is used, time delay must be used as shown. 2. Soft Start Capacitors (not used with GT-500 SM Control) GT300/400 - Part # 11-2067 GT-500 Optional Speed Mode -Part # 11-3536 3. Separate transformer required for PC3 lockout and Acusensors. 4. A wire connection is indicated by a black circle. Operator Switch Harness To N.O. Contacts of Activation Devices Red Operator Switch Harness Part # 22-0570 Figure 8 - General Wiring - GT-300/400 Single Inswing Presence Sensor 24 VAC Relay - Common 24 VAC Relay - Normally Open Approach Sensor 24 VAC Relay - Common 24 VAC Relay - Normally Open RS-12 Rocker Switch Part # 10-3528 Model 2200 Time Delay Prt # 243425 Gyro Tech Analog Control Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems 8-13-09 Page 13 www.NabcoEntrances.com Red Blk DN 0151 Red Model 2200 Time Delay Prt # 243425 Wht Red Red Not Used Potentiometer is located on side of case Mat Harness Part # 24-0535 Blue (not used) Operator Switch Harness Time Delay PC-6 Blk Lockout Power LED's Relay Lock out Red Org Org 24 VAC To Motor Leads 4 3 2 1 Brown "Y" harness Part # 22-0087 Gyro Tech Analog Control Operator Switch Harness Part # 22-0570 N.O. Operator Assembly Breakout Limit Switch N.C. (Red & Red) SAFETY BEAMS (IF USED) Notes: 1. If activation device is capable of holding a switch closure across Red and Black for the required door open time period, time delay (PN 24-3425) is not required. If a momentary activation device such as a wall swtich is used, time delay must be used as shown. 2. Soft Start Capacitors (not used with GT-500 SM Control) GT300/400 - Part # 11-2067 GT-500 Optional Speed Mode -Part # 11-3536 3. Separate transformer required for PC3 lockout and Acusensors. 4. A wire connection is indicated by a black circle. Operator Switch Harness CONTACTS GREY VIOLET Blue White Not Used Red Red Operator Switch Harness Part # 22-0570 Figure 9 - General Wiring – GT-300/400 Pair Outswing Presence Acusensor 1B 24 VAC Red Green Black Relay - COM 24 VAC White Relay - NO Approach Acusensor 1B Black 24 VAC Green 24 VAC White Relay - COM Blk Red Wht Soft Start Capacitor (refer to Note 2) Relay - NO RS-12 Rocker Switch Part # 10-3528 Soft Start Capacitor (refer to Note 2) Operator Assembly Breakout Limit Switch N.C. (Red & Red) Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems 8-13-09 Page 14 Green Black Relay - COM www.NabcoEntrances.com Blk DN 0157 Red Model 2200 Time Delay Prt # 243425 Wht Potentiometer is located on side of case Mat Harness Part # 24-0535 Blue (not used) Operator Switch Harness Blk Time Delay Lockout Power LED's PN 14-11807 PC-6 Lock out Relay Red Org Org 24 VAC To Motor Leads 4 3 2 1 Brown White Red Red N.O. CONTACTS Operator Assembly Breakout Limit Switch N.C. (Red & Red) SAFETY BEAMS (IF USED) Red Red Red Notes: 1. If activation device is capable of holding a switch closure across Red and Black for the required door open time period, time delay (PN 24-3425) is not required. If a momentary activation device such as a wall swtich is used, time delay must be used as shown. 2. Soft Start Capacitors (not used with GT-500 SM Control) GT300/400 - Part # 11-2067 GT-500 Optional Speed Mode -Part # 11-3536 3. Separate transformer required for PC3 lockout and Acusensors. 4. A wire connection is indicated by a black circle. Operator Switch Harness To N.O. Contacts of Activation Devices GREY VIOLET Blue Red "Y" harness Part # 22-0087 Red Red Operator Switch Harness Part # 22-0570 Red Gyro Tech Analog Control Operator Switch Harness Part # 22-0570 Figure 10 - General Wiring – GT-300/400 Pair Inswing Presence Acusensor 1B 24 VAC Red Green Black Relay - COM 24 VAC White Relay - NO Approach Acusensor 1B 24 VAC Red White Relay - NO 24 VAC Blk Red Wht Soft Start Capacitor (refer to Note 2) RS-12 Rocker Switch Part # 10-3528 Soft Start Capacitor (refer to Note 2) Operator Assembly Breakout Limit Switch N.C. (Red & Red) Panic Breakout Latch OHC Units Part # 11-0930 CU Units Part # 11-0941 Panic Breakout Latch OHC Units Part # 11-0930 CU Units Part # 11-0941 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems 8-13-09 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems Section B Sample Wiring Diagrams for GT-500 Low Energy Installations Page 16 Figure 10 - General Wiring - GT-500 Single Outswing Page 17 Figure 11 - General Wiring - GT-500 Single Inswing Page 18 Figure 12 - General Wiring – GT-500 Pair Outswing Page 19 Figure 13 - General Wiring – GT-500 Pair Inswing Page 20 Figure 14 - General Wiring - GT-500 with Electric Lock and Sequencer Page 15 www.NabcoEntrances.com 8-13-09 RS-12 Rocker Switch Part # 10-3528 Page 16 www.NabcoEntrances.com Blk Red DN 0159 Mat Harness Part # 24-0535 Wht (not used) Blue (not used) Soft Start Capacitor (refer to Note 2) No relay in this socket if GT-500 Standard Mode control is used Soft start capacitor is not used on GT-500 Standard Mode control. Therefore these leads are connected together 4 3 2 1 Not Used Red Red Operator Switch Harness Operator Assembly Breakout Limit Switch N.C. (Red & Red) Notes: 1. If activation device is capable of holding a switch closure across Red and Black for the required door open time period, time delay (PN 24-3425) is not required. If a momentary activation device such as a wall swtich is used, time delay must be used as shown. 2. Soft Start Capacitors for GT-500 Optional Speed (OS) Control (not used with GT-500 Standard Mode (SM) Control Part # 11-3536 3. A wire connection is indicated by a black circle Operator Switch Harness Part # 22-0570 Figure 11 - General Wiring - GT-500 Single Outswing Outside Switch Inside Switch Blk Red Wht Model 2200 Time Delay Prt # 243425 Gyro Tech Analog Control Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems 8-13-09 Page 17 Blk Red Wht Outside Switch Inside Switch RS-12 Rocker Switch Part # 10-3528 www.NabcoEntrances.com Red DN 0160 Wht (not used) Blue (not used) Mat Harness Part # 24-0535 Soft Start Capacitor (refer to Note 2) Soft start capacitor is not used on GT-500 Standard Mode control. Therefore these leads are connected together No relay in this socket if GT-500 Standard Mode control is used 4 3 2 1 Red Operator Switch Harness Red Red Operator Assembly Breakout Limit Switch N.C. (Red & Red) Panic Breakout Latch OHC Units Part # 11-0930 CU Units Part # 11-0941 Red Notes: 1. If activation device is capable of holding a switch closure across Red and Black for the required door open time period, time delay (PN 24-3425) is not required. If a momentary activation device such as a wall swtich is used, time delay must be used as shown. 2. Soft Start Capacitors for GT-500 Optional Speed (OS) Control (not used with GT-500 Standard Mode (SM) Control Part # 11-3536 3. A wire connection is indicated by a black circle To N.O. Contacts of Activation Devices Red Operator Switch Harness Part # 22-0570 Figure 12 - General Wiring - GT-500 Single Inswing Blk Model 2200 Time Delay Prt # 243425 Gyro Tech Analog Control Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems 8-13-09 Page 18 www.NabcoEntrances.com Outside Switch Inside Switch RS-12 Rocker Switch Part # 10-3528 Soft Start Capacitor (refer to Note 2) Blk Red Model 2200 Time Delay Prt # 243425 DN 0161 Wht (not used) Blue (not used) Mat Harness Part # 24-0535 Operator Switch Harness Not Used Red Red Soft start capacitor is not used on GT-500 Standard Mode control. Therefore these leads are connected together 4 3 2 1 Not Used Red Red Operator Switch Harness Part # 22-0570 No relay in this socket if GT-500 Standard Mode control is used "Y" harness Part # 22-0087 Gyro Tech Analog Control Operator Switch Harness Part # 22-0570 Notes: 1. If activation device is capable of holding a switch closure across Red and Black for the required door open time period, time delay (PN 24-3425) is not required. If a momentary activation device such as a wall swtich is used, time delay must be used as shown. 2. Soft Start Capacitors for GT-500 Optional Speed (OS) Control (not used with GT-500 Standard Mode (SM) Control Part # 11-3536 3. A wire connection is indicated by a black circle Operator Switch Harness Operator Assembly Breakout Limit Switch N.C. (Red & Red) Figure 13 - General Wiring – GT-500 Pair Outswing Blk Red Wht Soft Start Capacitor (refer to Note 2) Operator Assembly Breakout Limit Switch N.C. (Red & Red) Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems 8-13-09 Page 19 Blk Red Wht www.NabcoEntrances.com Outside Switch Red Model 2200 Time Delay Prt # 243425 DN 0162 Wht (not used) Blue (not used) Mat Harness Part # 24-0535 Operator Switch Harness Red "Y" harness Part # 22-0087 Red Red No relay in this socket if GT-500 Standard Mode control is used Soft start capacitors are not used on GT-500 Standard Mode control. Therefore these leads are connected together 4 3 2 1 Red Red Operator Assembly Breakout Limit Switch N.C. (Red & Red) Red Red Red Notes: 1. If activation device is capable of holding a switch closure across Red and Black for the required door open time period, time delay (PN 24-3425) is not required. If a momentary activation device such as a wall swtich is used, time delay must be used as shown. 2. Soft Start Capacitors for GT-500 Optional Speed (OS) Control (not used with GT-500 Standard Mode (SM) Control Part # 11-3536 3. A wire connection is indicated by a black circle Operator Switch Harness To N.O. Contacts of Activation Devices Operator Switch Harness Part # 22-0570 Red Gyro Tech Analog Control Operator Switch Harness Part # 22-0570 Figure 14 - General Wiring – GT-500 Pair Inswing Blk Soft Start Capacitor (refer to Note 2) Inside Switch RS-12 Rocker Switch Part # 10-3528 Soft Start Capacitor (refer to Note 2) Operator Assembly Breakout Limit Switch N.C. (Red & Red) Panic Breakout Latch OHC Units Part # 11-0930 CU Units Part # 11-0941 Panic Breakout Latch OHC Units Part # 11-0930 CU Units Part # 11-0941 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems 8-13-09 Transformer P/N 14-2101 24 VAC 24 VAC www.NabcoEntrances.com 12V N.O. COM N.C. RELAY1 N.C. WET1 WET DRY COM COM DRY1 WET2 RELAY 2 DOO (DELAY ON TIME ON OPERATE) RELAY 2 STRIKE POWER (To match strike voltage) N.O. COM RELAY2 RELAY 1 ON TIME WET3 RED BLACK RADIO RECEIVER 4-TERM (IF USED) Activation Connector on Analog Control DRY2 SW 1 MODE SWITCH COM DN 0302 INTERIOR PUSH SWITCH Normally Open - Dry Contacts EXTERIOR KEY SWITCH Normally Open - Dry Contacts Figure 15 - GT-500 with Electric Lock & Sequencer Wire Transient Voltage Suppresor (supplied) directly to strike or magnet. Not polarity sensitive. TVS If magnetic lock or fail safe ELECTRIC strike used, STRIKE connect lock wires to COM and N.C. terminals of Multi-Module 120 VAC 24V iti-200S RL2 LED LED Power RL1 Power Page 20 N.O. Note: 1. A black circle indicates a wire connection. 2. Power supply inputs not polarity sensitive. Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems 8-13-09 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems Troubleshooting: Symptom Action/Cause Solution Operator does not function 1. Check Fuse 2 (F2). 2. Check for 120 VAC at connector J5 3. Check power to activation device at connector J1. 4. Check Fuse 1 (F1) 1. Replace fuse 2. Check incoming power. If power is good, check connection to motor. Replace motor if necessary 3. If power exceeds 0.5 amps at 24 VAC, replace with lower draw sensor. If blown, replace fuse. 4. If F1 is OK, check power to activating devices at J2. Voltage is too low, reduce accessory load Adjustment of Hydraulic Closer has no effect. (GT710 only) Door slams closed Check 4 pin motor connector on the board For GT-710’s only: Pin #2 and #4 must be jumped by a wire 1. GT-710: Main speed on hydraulic closer not adjusted properly 2. GT300/400/500: Closing speed not adjusted or motor circuit open 1. All units: Back check speed not adjusted 2. GT-710: magnet not in proper location 3. GT-300/400/500: Operator not preloaded correctly Check door activation device power consumption 1. GT-500: Check polarity of motor input wires at connector on motor 2. All units: motor/operator coupling or spyder coupling loose between motor and operator 1. GT-710: The fully open door position is greater than 90º and the back check adjustment on the hydraulic closer is overriding the controls of the Magnum board 2. All units: Door is not going into back check even though it is reaching 90 degrees 1. Turn main speed in direction of turtle Door slams open Fuse 2 (F2) blows when door open is triggered Motor spins when activated but door does not open Back check adjustment on Magnum board has no effect No back check Door does not stay tightly closed Page 21 1. GT-710: Magnets on main sprocket not in correct position. 2. GT-300/400/500: back check switch not closing at correct position 1. All units: Preload on swing arm is not correct 2. GT-710: Spring adjustment not correct on LCN closer. 3. GT-710: Building stack pressure is excessive 2. Adjust closing speed on Magnum control 2. check for open connection on motor circuit 1. Adjust back check speed on hydraulic closer or Magnum control 2. Adjust back check potentiometer or relocate magnet 3. Pre-load operator by correctly installing arm on operator spindle as per hardware installation manual If power draw exceeds 0.5 amps at 24 VAC, replace with lower draw sensor 1. Reverse motor leads on motor 2. Remove and separate motor and operator. Inspect couplings for looseness 1. Adjust the back check screw on the bottom of the header out one turn 2. Reposition magnet on GT-710 or correctly pre-load arm on GT-300/400/500 as per hardware installation manual 1. Follow instructions in GT-710 hardware installation manual to properly align magnets. 2. Follow instructions in GT-GT300/400/500 hardware installation manual to properly pre-load operator 1. Position arm as shown in hardware installation manual 2. Adjust spring tension on LCN closer as per GT-710 hardware installation manual. 3. Upgrade operator unit to GT 500 www.NabcoEntrances.com 8-13-09 Model 1400 Analog Control Manual for Gyro Tech Swing Door Systems Troubleshooting continued …. Symptom Action/Cause Solution Presence Sensor does not function 1. All units: No power to sensor or defective sensor. 2. All units: Sensor not connected to White wire 1. All units: No power to sensor or defective sensor. 2. All units: Sensor not connected to Violet wire All units: Connection of sensor to wiring harness was to “Safety” not “Safety w/ Lockout” All units: Connection of accessories was made to “Safety w/Lockout” not “Continuous Safety” 1. Check harness wiring as per applicable section Swing Side Door sensor does not function Swing Side Presence Sensor is activated by opening or closing door Swing Side ACUGARD 2, swing side floor mat, safety holding beams or other accessories do not function while door is moving Sensor shows activation signal sent, but door does not open One sensor does not activate both doors on a simultaneous pair Page 22 All units: Sensor not connected properly to activation connector All units: Sensor is not connected to both control boards 2. Connect the output of the sensor to the Red # 5 and White # 4 connections on the terminal block. 1. Check harness wiring as per applicable section. 2. Connect the output of the sensor to the Red # 5 and Violet # 3 connections on the terminal block Rewire Safety Sensor to “Safety w/Lockout” connector. (pins Red # 5 and White # 4 connections on the terminal block.) Rewire accessory to “Continuous Safety” connection (Red # 5 and Violet # 3 connections on the terminal block.) Check harness wiring as per applicable section Install simultaneous pair harness (P/N 229953) www.NabcoEntrances.com 8-13-09