Typical Uses
ARCHITECTURAL: Building fronts, downspouts, flashing, gutters, roofing, screening, spouting
AUTOMOTIVE: Gaskets, radiators ELECTRICAL: Bus bars, conductivity wire, contacts, switches, terminals,
cable wrap, field coils, transformers HARDWARE: Ball floats, burrs, cotter pins, nails, rivets, soldering copper,
tacks MISCELLANEOUS: Anodes, chemical process equipment, kettles, pans, vats, medical, clad metals
Composition-Percent
Nominal
Min
Max
.04
99.90
-
Copper
Oxygen
Common Fabrication Processes
Blanking; coining; coppersmithing; drawing; etching; forming and bending; heading and upsetting; hot forging and
pressing; piercing and punching; roll threading and knurling; shearing; spinning; squeezing and swaging; stamping.
-
Physical Properties
English Units
C G.S. Units
Melting Point (Liquidus)
Melting Point (Solidus)
Density
Specific Gravity
Coefficient of Thermal Expansion
Coefficient of Thermal Expansion
Coefficient of Thermal Expansion
Thermal Conductivity
Electrical Resistivity (Annealed)
Electrical Conductivity* (Annealed)
Thermal Capacity (Specific Heat)
Modulus of Elasticity (Tension)
Modulus of Rigidity
1,981°F
1,949°F
.321-.323 lb./cu. in. @ 68°F
8.89-8.94
.0000094 per °F from 68°F to 212°F
.0000096 per °F from 68°F to 392°F
.0000098 per °F from 68°F to 572°F
226 Btu./sq. ft./ft/hr./°F @ 68°F
10.3 Ohms (circ. mil./ft.) @ 68°F
100% IACS @ 68°F
.092 Btu./lb./°F @ 68°F
17,000,000 psi
6,400,000 psi
1,083°C
1,065°C
8.89-8.94 gm./cu. cm. @ 20°C
8.89-8.94
.0000170 per °C from 20°C to 100°C
.0000173 per °C from 20°C to 200°C
.0000177 per °C from 20°C to 300°C
.934 cal./sq. cm./cm./sec./°C @ 20°C
1.71 Microhm-cm. @ 20°C
.586 Megohm-cm. @ 20°C
.092 cal./gm./°C @ 20°C
12,000 Kg/sq. mm
4,500 Kg/sq. mm
*Volume and weight basis
Fabrication Properties
Suitability for being joined by:
Soldering
Brazing
Oxyacetylene Welding
Carbon Arc Welding
Gas Shielded Arc Welding
Coated Metal Arc Welding
Spot
Resistance Welding
Seam
Butt
Capacity for being Cold Worked
Excellent
Capacity for being Hot Formed
Excellent
Hot Forgeability Rating (Forging Brass =100)
65
Hot Working Temperature
1,400-1,600°F or 750-875°C
Annealing Temperature
600-1,200°F or 315-650°C
Machinability Rating (Free Cutting Brass =100)
20
1.0 in.
32,000
34,000
36,000
38,000
42,000
50,000
55,000
57,000
34,000
32,000
36,000
38,000
50,000
32,000
45,000
10,000
11,000
28,000
30,000
36,000
45,000
50,000
53,000
10,000
10,000
28,000
30,000
45,000
10,000
40,000
-
Elongation
in 2” - %
Reduction
of Area - %
Nominal
Yield
Strength
(½% Extension
Under Load)
psi
Nominal
Tensile
Strength
psi
Temper
Size
Section
Form
0.250 in.
0.050 mm
0.025 mm
Eighth Hard
Quarter Hard
Half Hard
Hard
Spring
Extra Spring
As Hot Rolled
0.050 mm
Eighth Hard
Quarter Hard
Hard
As Hot Rolled
Hard
I
45
45
30
25
14
6
4
4
45
50
40
35
12
50
20
Nominal
Rockwell
Hardness
F
40
45
60
70
84
90
94
95
45
40
60
70
90
40
85
B
30T
10
25
40
50
60
62
10
25
50
45
25
36
50
57
63
64
-
Shear
Strength
psi
{
Mechanical Properties
0.040 in.
FLAT
PRODUCTS
S
Excellent
Good
Not Recommended
Fair
Fair
Not Recommended
Not Recommended
Not Recommended
Good
22,000
23,000
25,000
25,000
26,000
28,000
29,000
29,000
23,000
22,000
25,000
25,000
28,000
22,000
26,000
Fatigue Strength
psi
11,000
13,000
13,000
14,000
-
Million
Cycles
100
100
100
100
-
The values listed above represent reasonable approximations suitable for general engineering use. Due to commercial variations in composition and to manufacturing limitations, they
should not be used for specification purposes. See applicable A.S.T.M. specification references.
owned by:
WWW.HUSSEYCOPPER.COM
100 Washington Street
Leetsdale, PA 15056-1099
724-251-4200 Main
800-733-8866 Toll-Free
724-251-4243 Fax