Contents - Sun Hydraulics
Transcription
Contents - Sun Hydraulics
Contents The Sun Product . . . . . . . . . . . . . . . . iii Technical Product Information . . v SAE Counterbore Diameters Table. . . . . . . . . . . . . . . . . . . . . . . . . . vii SAE Flange Pattern Specifications Table . . . . . . . . . . . . . . viii Relief Assemblies Relief Valves Two Port Relief . . . . . . . . . . . . . . . . 1 Pilot Operated . . . . . . . . . . . . . . . 2 Direct Acting . . . . . . . . . . . . . . . . 2 Line Mounted Assemblies. . . . . . . . . . . 4 Three Port Relief . . . . . . . . . . . . . . . 11 Pilot Operated with Vent . . . . . . . 12 Line Mounted Assemblies. . . . . . . . . . . 14 Sequence Assemblies Sequence Valves Pilot Operated . . . . . . . . . . . . . . . . . Direct Acting . . . . . . . . . . . . . . . . . . Line Mounted Assemblies. . . . . . . . . . . Direct Acting with Reverse Free Flow Check Valves. . . . . . . . . Line Mounted Assemblies . . . . . . . . 20 20 22 28 30 Needle Assemblies Needle Valves Fully Adjustable . . . . . . . . . . . . . . . .110 Fully Adjustable with Reverse Free Flow Check . . . . . . . .110 Line Mounted Assemblies . . . . . . . . . . .113 Pressure Compensated Flow Control Assemblies Flow Control Valves Fixed Orifice . . . . . . . . . . . . . . . . . . .117 Pressure Compensated. . . . . . . . . .118 Pressure Compensated with Free Flow Check . . . . . . . . . . . . .118 Line Mounted Assemblies . . . . . . . . . . .120 Fully Adjustable Pressure Compensated with Free Flow Check . . . . . . . . . . . . . . . . . . .126 Line Mounted Assemblies . . . . . . . . . . .128 Priority Flow Control Assemblies Priority Flow Control Valves Bypass/Restrictive, Fixed Orifice . . . . . . . . . . . . . . . . . . . . . . .134 Line Mounted Assemblies . . . . . . . . . . .136 Pressure Reducing Assemblies Sandwich Assemblies Reducing Valves Pilot Operated . . . . . . . . . . . . . . . . . 34 Line Mounted Assemblies. . . . . . . . . . . 36 Sandwich Body Technical Product Information . . . . . . . . . . . . . .140 Studkits for ISO 03 and ISO 05 Sandwich Bodies . . . . . . . . . . . . .142 ISO 03 Studkits . . . . . . . . . . . . . . .142 ISO 05 Studkits . . . . . . . . . . . . . . .142 Studrod Length Determination Chart. . . . . . . . . . . . . . . . . . . . . . .143 ISO 03 / CETOP 3 Assemblies Relief . . . . . . . . . . . . . . . . . . . . . . .145 Sequence . . . . . . . . . . . . . . . . . . . .148 Reducing . . . . . . . . . . . . . . . . . . . .149 Reducing/Relieving . . . . . . . . . . . .150 Counterbalance . . . . . . . . . . . . . . .151 Pilot-to-Open Check . . . . . . . . . . .152 Check. . . . . . . . . . . . . . . . . . . . . . .153 Priority Flow Control . . . . . . . . . .154 Flow Control . . . . . . . . . . . . . . . . .155 Circuit Saver . . . . . . . . . . . . . . . . .158 ISO 05 / CETOP 5 Assemblies Relief . . . . . . . . . . . . . . . . . . . . . . .163 Sequence . . . . . . . . . . . . . . . . . . . .164 Reducing . . . . . . . . . . . . . . . . . . . .165 Reducing/Relieving . . . . . . . . . . . .166 Counterbalance . . . . . . . . . . . . . . .167 Pilot-to-Open Check . . . . . . . . . . .168 Check. . . . . . . . . . . . . . . . . . . . . . .169 Flow Control . . . . . . . . . . . . . . . . .170 ISO 05 / CETOP 5 with X and Y Assemblies Relief . . . . . . . . . . . . . . . . . . . . . . .173 Reducing / Relieving Assemblies Reducing/Relieving Valves Pilot Operated . . . . . . . . . . . . . . . . . 42 Direct Acting . . . . . . . . . . . . . . . . . . 42 Line Mounted Assemblies. . . . . . . . . . . 44 Counterbalance Assemblies Counterbalance Valves Three Port Standard . . . . . . . . . . . . . Line Mounted Assemblies. . . . . . . . . . . Four Port Vented . . . . . . . . . . . . . . . Line Mounted Assemblies. . . . . . . . . . . 50 52 70 72 Pilot-to-Open Check Assemblies Pilot-to-Open Check Valves Three Port . . . . . . . . . . . . . . . . . . . . Pilot Operated . . . . . . . . . . . . . . . Line Mounted Assemblies. . . . . . . . . . . Four Port . . . . . . . . . . . . . . . . . . . . . Vented, Four Port Cavity . . . . . . . Line Mounted Assemblies. . . . . . . . . . . 77 78 80 93 94 96 Check Assemblies Check Valves 1 to 2 Free Flow. . . . . . . . . . . . . . . . 102 2 to 1 Free Flow. . . . . . . . . . . . . . . . 102 Line Mounted Assemblies. . . . . . . . . . . 104 US Selected Assemblies Catalogue #999-901-192 i Sequence . . . . . . . . . . . . . . . . . . . . 175 Reducing . . . . . . . . . . . . . . . . . . . . 176 Reducing/Relieving . . . . . . . . . . . 177 Counterbalance . . . . . . . . . . . . . . . 178 Pilot-to-Open Check . . . . . . . . . . . 179 Check . . . . . . . . . . . . . . . . . . . . . . 180 Flow Control . . . . . . . . . . . . . . . . . 181 ISO 07 / CETOP 7 Assemblies Relief. . . . . . . . . . . . . . . . . . . . . . . 183 Sequence . . . . . . . . . . . . . . . . . . . . 185 Reducing . . . . . . . . . . . . . . . . . . . . 186 Reducing/Relieving . . . . . . . . . . . 187 Counterbalance . . . . . . . . . . . . . . . 188 Pilot-to-Open Check . . . . . . . . . . . 189 Check . . . . . . . . . . . . . . . . . . . . . . 190 Flow Control . . . . . . . . . . . . . . . . . 191 Circuit Saver . . . . . . . . . . . . . . . . . 192 ISO 08 / CETOP 8 Assemblies Relief. . . . . . . . . . . . . . . . . . . . . . . 193 Sequence . . . . . . . . . . . . . . . . . . . . 195 Reducing . . . . . . . . . . . . . . . . . . . . 196 Reducing/Relieving . . . . . . . . . . . 197 Counterbalance . . . . . . . . . . . . . . . 198 Pilot-to-Open Check . . . . . . . . . . . 199 Check . . . . . . . . . . . . . . . . . . . . . . 200 Flow Control . . . . . . . . . . . . . . . . . 201 Circuit Saver . . . . . . . . . . . . . . . . . 202 Standard Assemblies Cushion Lock Valves Technical Information. . . . . . . . . . 204 Assemblies . . . . . . . . . . . . . . . . . . 205 Hydrostatic Transmission and Hot Oil Shuttle Technical Information. . . . . . . . . . 213 Assemblies . . . . . . . . . . . . . . . . . . 214 Line Mounted Regenerative Circuits Technical Information. . . . . . . . . . 223 Assemblies . . . . . . . . . . . . . . . . . . 224 Direct Motor Mounted Technical Information. . . . . . . . . . 229 Char-Lynn S Series Assemblies . . 230 Danfoss (OMP/OMR Series and OMT Series) Assemblies . . . 237 General Information Cartridge Control Options . . . . . . . . 244 Cartridge Control Kits . . . . . . . . . . . 245 Cavity Plugs . . . . . . . . . . . . . . . . . . . 246 Solenoid Electrical Connector Options . . . . . . . . . . . . . 248 Orifice Pressure Drop Data . . . . . . . 249 Visit www.sunhydraulics.com for current Tooling infomation. Model Code Index . . . . . . . . . . . . . . 264 Warranty . . . . . . . . . . . . . . . . . . . . . 276 SUN RECOMMENDED QUANTITY DISCOUNTS FOR STANDARD VALVES One line item One order One shipment F.O.B. Sarasota, FL. USA Prices shown for SUN Cavity form tools are net and not subject to discounts. Prices for Custom Products and Modifications of Standard Valves are by quotation only. Quantity: 1-2 Discount: List 3-9 7% 10-29 15% 30-99 25% 100-299 35% 300-999 On Request Consult your SUN distributor for terms and conditions covering blanket orders or orders for scheduled repetitive shipments. Sun Hydraulics Corporation reserves the right to change existing prices and discounts at any time without notice to its customers. Selling prices are governed by the price list in effect at the time of acceptance of a purchase order. MODEL CODES PRINTED IN RED IN THIS CATALOGUE ARE PREFERRED PRODUCTS AND ARE READILY AVAILABLE. Specifications, descriptions and illustrative material contained herein were as accurate as known at the time this publication was approved for printing. Sun Hydraulics Corporation reserves the right to discontinue models at any time, or change prices, specifications or designs without notice or incurring obligation. This catalogue is published by Sun Hydraulics Corporation 1500 West University Parkway, Sarasota, FL 34243 USA. All rights reserved. This book, or any part thereof, may not be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage and retrieval systems, for any purpose without the express written permission of Sun Hydraulics Corporation. © 2002 Sun Hydraulics Corporation Sarasota, FL 34243 USA Printed in the United States of America Catalogue #999-901-192 ii US Selected Assemblies Catalogue #999-901-192 Overview THE SUN PRODUCT Five Cartridge Sizes Flows to 200 GPM (400 GPM for some applications). Sun screw-in cartridge type hydraulic valves for industrial and mobile applications are basic building blocks. Each cartridge contains the active elements needed for hydraulic control functions in a convenient and reliable lightweight envelope. Cartridges are available in standard pressure ranges up to 5000 psi (6000 psi in some models). Every cartridge receives a complete functional test prior to shipment. The use of cartridge valves in hydraulic systems will: Sun screw-in cartridges, available in five sizes, are suitable for both mobile and industrial applications. • • • • • • • • Improve system reliability Simplify circuits Reduce leakage points Reduce piping costs Save space and weight Simplify service Reduce assembly time Reduce spare parts inventory A significant advantage in the design of Sun cartridges is that the working parts “float” in the body, so they are not susceptible to binding caused by overtorquing, during installation in the cavity. (See illustration on inside front cover.) Sun utilizes relatively few cartridge cavities throughout its entire range of cartridge products. Many valve functions and ranges can be interchanged in the same cavity. The result is greatly increased flexibility, and the capability to modify circuits without disturbing any piping, breaking unions or unplumbing any valves. A wide range of standard bodies are available to simplify the installation of Sun cartridges in new and existing circuits. US Selected Assemblies Catalogue #999-901-192 iii Line Mounted Bodies Sun manufactures a wide range of standard bodies to simplify the installation of cartridges in new and existing circuits. SAE O-ring straight thread, NPTF, BSPP, SAE Code 61 and 62 split flange, and other ports are available. Two hydraulic functions are frequently combined in a single body to simplify piping. All bodies are available in aluminum or ductile iron. Overview THE SUN PRODUCT Sandwich Bodies and Subplates Sun's sandwich valves and subplates are complete circuit elements which mount directly under the solenoid valve. Most hydraulic functions are available in sandwich bodies and subplates. They are available in aluminum or ductile iron and provide a simple method of incorporating circuit controlling components right at the solenoid valve. Sandwich valves and subplates can be easily assembled with studrods and studnuts. The result is a clean, neat assembly with a minimum of external piping that is easily accessible for modification. Pre-packaged Valve Assemblies Sandwich bodies and subplates provide a simple method of incorporating controlling components right at the solenoid valve. A wide variety of pre-packaged valve assemblies are available to perform many of the more common hydraulic circuit functions. These assemblies incorporate two or more different cartridges in a manifold body with a choice of porting options and are available in aluminum or ductile iron. Direct Motor Mount Bodies Mounting configurations offered by Sun match the mounting patterns of selected Char-Lynn, Danfoss, Staffa, HPI, Parker Ross, and White motors. These valve assemblies provide relief, counterbalance, and flow control functions for mounting directly to a motor, and are available in aluminum or ductile iron. Pre-packaged valve assemblies for common hydraulic circuit functions. Direct Motor Mount bodies for commercial hydraulic motors. Integration into Hydraulic Components Directly integrating cartridge valves into the housing of other components is a very cost effective and compact method of packaging multiple hydraulic functions. Cavity form tools for machining the cartridge cavity are readily available from Sun. Custom Valve Packages It is often desirable and economical to incorporate several cartridges into a special, application specific manifold body to simplify a circuit, reduce piping costs, fit into a confined space, or solve a mounting problem. Direct integration is cost-effective and compact. Custom valve packages for specific applications. Sun Hydraulics and its network of Authorized Distributors (see inside back cover) will work with you to develop customized solutions to your particular application problems. iv US Selected Assemblies Catalogue #999-901-192 Cartridges TECHNICAL PRODUCT INFORMATION Cartridge Installation Sun cartridge valves are manufactured from carbon steel with all external parts zinc plated to protect against corrosion. Critical internal working parts (sliding spool valves often have a clearance between fixed and working parts of 5 microns or less) are heat treated and precision ground or lapped, to ensure repeatable, reliable performance. Sun cartridge valves are available in five different sizes with capacities doubling from one size to the next. These cartridges can only be used in a Sun cavity that matches the external configuration of the cartridge. When installing cartridges in their cavities, they should be torqued to the recommended value. All cartridges have Buna-N seals as standard, with Viton optional. Buna-N seals have an operating range of -50° F to 200° F. Viton seals have an operating range of 0° F to 250° F. Filtration As with any precision hydraulic component, clean oil contributes to long life and reliable performance. The most common cause of failure of a cartridge is dirt in the hydraulic fluid, which can then lodge in the working parts of the cartridge and interfere with operation. Most Sun pilot operated valves feature a 150 micron stainless steel screen or equivalent, to protect the control orifice from contamination. This filter is produced from electrochemically etched stainless steel sheets to provide a consistent screening material. It is recommended that hydraulic fluid used in systems with Sun valves have an ISO 4406 contamination level of 18/15 or better at all times. Consult your Authorized Distributor for filtration requirements to meet this cleanliness level. Pressure and Flow Rating – Performance Data All performance data in this catalog is derived using Chevron ISO Grade 32 petroleum based hydraulic fluid having a specific gravity of 0.87 at 60° F. All tests are conducted at 110° F. Leakage is often specified in units of drops per minute in this catalog. For reference, 250 drops equal 1 cubic inch. All cartridge valves go through functional testing before shipment. Tests are performed using petroleum based hydraulic fluid (ISO Grade 32) at a temperature of 110° F (SUS = 130). Test stand cleanliness is maintained at ISO 17/14 or better. All performance data provided is developed in our laboratory. Standard and special set pressure controls are set at the following flow rates: ■ Materials ■ All manifolds and bodies are available in aluminum or ductile iron. Aluminum bodies are made of wrought 6061-T6 grade aluminum and have a maximum pressure rating of 3000 psi, a proof rating of 6000 psi, and a burst rating of 12,000 psi. Ductile iron bodies are made of continuous cast, grade 65-45-12 iron. Ductile iron bodies have a maximum pressure rating of 5000 psi, with a proof rating of 10,000 psi, and burst rating of 20,000 psi. Porting Options Sun offers many porting options in its mounting configurations, including, but not limited to: SAE Code 61 and 62 split flanges, NPTF dry seal threads, SAE O-ring threaded ports, and BSPP (Whitworth) threads. ■ Cartridge valves are basic service items and they are easily removed in the field. See Caution below and the Sun Service Bulletin for details. A non-functioning cartridge should be returned to Sun through your local Authorized Distributor for evaluation. A full report of our findings will be issued upon request. Caution! – Prior to removing any cartridge: 1. Refer to the equipment manufacturer's documentation for recommendations relating to precautions for securing any moving elements associated with the hydraulic system or equipment. (If documentation does not exist, ensure that all loads are adequately supported.) 2. Ensure that the hydraulic system is de-pressurized. Sandwich Interface Patterns Most sandwich and subplate bodies are available in the following interface configurations: ISO 02 ISO 03 ISO 05* ISO 07 ISO 08 NFPA D02 NFPA D03 NFPA D05 NFPA D07 NFPA D08 * Available with X and Y ports v NG 4 NG 6 NG 10 NG 16 NG 25 Load Control Valves - 2 in.3/min. Pressure Reducing Valves - 0 flow (blocked control port). All Other Valves - 4 GPM. Sun Service Instructions Please note that some bodies with SAE O-ring threaded ports utilize a modified spot face diameter for conservation of materials. Unless otherwise specified, Sun cartridges are rated to 5000 psi (6000 psi intermittent). All Sun cartridges are designed with a 4:1 safety factor. This means the minimum burst pressure is at least four times the maximum rated operating pressure. US Selected Assemblies Catalogue #999-901-192 Testing Cartridges TECHNICAL PRODUCT INFORMATION Solenoid Cartridge Valves Sun Hydraulics offers a variety of pilot solenoid cartridges and direct acting full flow solenoid cartridges to suit most application requirements. ■ ■ Full Flow Valves Rated for Reliability ■ ■ ■ Direct acting full flow solenoid cartridges will operate reliably at their maximum pressure (3600 psi) and flow ratings (10 GPM). All pressure and flow ratings are conservative to ensure that the final circuit will function as the designer intended. These solenoid cartridge valves will operate at rated conditions with a life expectancy in excess of 20 million cycles. Connector and Voltage Options ■ ■ ■ ■ ■ Multiple Versions Two port, 2 position / 2-way solenoids are available in either spool or poppet versions, each offered in both normally open and normally closed configurations. ■ ■ ■ ■ Spool version exhibit maximum leakage rates of 5 in3/min. at 3600 psi and are recommended for high flow requirements where leakage is not critical. Poppet version exhibit maximum leakage rates of 10 drops/min. at 3600 psi. Three port, 2 position / 3-way spool type cartridges exhibit all of the features of the two position / 2-way spool cartridges. Solenoid cartridges feature a standard push-type manual override. Designed for Application Flexibility These direct acting valves require no minimum pressure for their operation. ■ ■ An efficient coil and tube design generates maximum force output with only 22 watts of power, so the valves exhibit consistent and reliable operation. The high force output of the solenoid ensures that there is enough power to overcome flow forces that may otherwise prevent the valve from shifting. Within each cartridge version, the normally open and normally closed configurations have virtually identical performance, allowing them to be used interchangeably. Together these features afford the circuit designer greatly increased flexibility. ■ All solenoids are DC type devices. An internal bridge rectifier is used in the coil for AC applications. Coils will operate reliably from 80% to 120% of the rated voltage with a maximum ambient temperature of 122ºF. DC coils are offered in 12 and 24-volt versions with twin lead, DIN or AMP® Junior Timer connectors. AC coils are available in both 115 or 230-volt options and feature DIN connectors. All coils employ internal transient voltage suppression protection to protect externally connected electrical switching. High Pressure Solenoid Pilot Controls ■ ■ These small spool-type cartridges handle flows up to approximately .25 GPM and will accommodate pressure up to 5000 psi at all ports. All pilot solenoid cartridges are rated for a fatigue life of greater than 20 million cycles at their maximum working pressure and flow ratings. Low Power Consumption ■ Integrated Pilot Control While all of the pilot control solenoid cartridges can be used individually in manifolds to control other devices, the 2-way cartridges offer the added benefit of being able to be directly installed into other Sun cartridges to provide electrically operated high flow and high pressure control. ■ ■ ■ ■ ■ ■ ■ ■ Voltage and temperature tolerances of the pilot solenoids are identical to those of the full flow valves. All coils employ internal transient voltage suppression protection to protect externally connected electrical switching. Both AC and DC coils are offered with AC coils employing an internal bridge rectifier. DC coils are offered in various voltage options from 6 to 48-volts. Connector options include DIN, SAE twin spade and twin leads. vi The T-8A cavity is offered as a control option on many of Sun’s ventable and pilot operated cartridges to offer high performance, 5000 psi electrically controlled products at a competitive price. Directly integrating the electrical control in the main stage function results in a product that offers improved control characteristics; separate pilot lines are eliminated and only a single cavity needs to be machined to accommodate both the control and primary function. Sun also offers a range of cartridges that incorporate solenoid pilot controls to provide directional control for flow ranges from 15 to 120 GPM. 2-way or 3-way Pilot control solenoid cartridges are available in either a two port, 2 position / 2-way (DAAA), or a three port, 2 position / 3-way (DBAA), each of which exhibits internal leakage rates of 10 drop/min. maximum at 5000 psi. ■ The highly efficient tube design of the pilot solenoids requires only 12 watts to shift the valve. AC coils are offered in 115- and 230-volt options and feature DIN connectors. ■ ■ ■ The 2-way versions fit into Sun’s existing T-8A cavity. The 3-way versions fit the T-9A cavity. Both are offered in normally open and normally closed configurations with a variety of voltage and connector options. The pilot control solenoid valves include a push-type manual override as a standard feature. US Selected Assemblies Catalogue #999-901-192 Line Mount Bodies LOCATE LINE MOUNT BODIES WITH ALL NECESSARY SPECIFICATIONS Sun offers many single and multiple cavity standard line mount manifolds, and many sandwich, motor mount bodies and subplates that are available in a choice of aluminum (3000 psi/210 bar) or ductile iron (5000 psi/350 bar). Ports include NPTF, SAE, BSPP and Code 61 and Code 62 flanges. Go to www.sunhydraulics.com. Example: Click Product: Manifolds: Line Mount: Flow Controls: Inline: and a pop-up menu shows all the available SAE Ported Bodies within your selection (see below). When you click the body in the appropriate Cavity column, the body page will show all measurements, Technical Data and full orientation views of all body faces. See Technical Information section of web site for additional information. US Selected Assemblies Catalogue #999-901-192 vii NOTES viii US Selected Assemblies Catalogue #999-901-192 Two Port Relief Assemblies Cartridge Type 2 Page Pilot Operated 2 Direct Acting 2 1 2 1 Line Mounted Assemblies (Body Type) 2 90 Degree 4 90 Degree with Gauge Port 90 Degree 1.50" SAE C62 Flange Port 5 5 Through Port 6 2.00" SAE C61/62 Flange Port, 2 Cavities 8 1 2 G 1 2 1 1 G 2 1 1 1 Cross-Port, 2 Cavities 2 9-10 2 G 1 1 2 Cross-Port, 2 Cavities with 2 Gauge Ports Cross-Port, 1.50" SAE C61/C62 Flange Port, 2 Cavities 2 G US Selected Assemblies Catalogue #999-901-192 1 10 10 TWO PORT RELIEF Relief Valves PILOT OPERATED 2 1 Capacity Typical Cartridge Model Code Cartridge Dimensions c b L C 12 GPM RPCC – LAN T - 162A 1.22 3/4” 2.11 2.17 2.31 Installation Torque (lb. ft.) 25/30 25 GPM RPEC – LAN T - 10A 1.56 7/8” 2.00 2.06 2.25 30/35 50 GPM RPGC – LAN T - 3A 1.88 1 1/8” 2.12 2.18 2.38 45/50 Cavity a K 100 GPM RPIC – LAN T - 16A 2.44 1 1/4” 2.44 2.47 2.69 150/160 200 GPM RPKC – LAN T - 18A 3.13 1 5/8” 2.81 2.94 3.06 350/375 OPTION ORDERING INFORMATION RP ✱ C – ✱ ✱ ✱ Full Adjustment 5 Turns + - Nominal Capacity Base Price C 12 GPM* c b Locating Shoulder Control** Adjustment Range L Standard Screw N Buna-N V Viton E 25 GPM C Tamper Resistant W 150 - 4500 psi G 50 GPM K Handknob B 50 - 1500 psi I Seal A 100 - 3000 psi C 150 - 6000 psi 100 GPM K 200 GPM N 60 - 800 psi Q 60 - 400 psi a 2 Outlet Adjustment Range Options: A, B, C, and W are standard set at 1000 psi. N Option is standard set at 400 psi. Q Option is standard set at 200 psi. * Minimum setting 75 psi on all ranges. Customer may specify pressure setting. ** See page 244 for information on Control Options Inlet 1 DIRECT ACTING Typical Cartridge Model Code 12 GPM RDBA – LAN T - 162A 1.22 3/4” 2.11 2.17 Installation Torque (lb. ft.) 25/30 25 GPM RDDA – LAN T - 10A 1.56 7/8” 2.38 2.44 30/35 Capacity 2 1 Cartridge Dimensions c b L Cavity a C 50 GPM RDFA – LAN T - 3A 1.88 1 1/8” 2.50 2.56 45/50 100 GPM RDHA – LAN T - 16A 2.44 1 1/4” 3.25 3.31 150/160 200 GPM RDJA – LAN T - 18A 3.13 1 5/8” 3.94 4.07 350/375 OPTION ORDERING INFORMATION RD ✱ A – ✱ ✱ ✱ Full Adjustment 5 Turns + - Nominal Capacity c b Base Price Control** Adjustment Range Seal B 12 GPM L Standard Screw A 500 - 3000 psi N Buna-N D 25 GPM C Tamper Resistant W 1000 - 4500 psi V Viton F 50 GPM B 300 - 1500 psi H 100 GPM C 1000 - 6000 psi J 200 GPM D 25 - 800 psi Locating Shoulder E 100 - 400 psi S 50 - 200 psi a 2 Outlet Inlet 1 U.S. Patent #4,742,846 European Patent Pending ** See page 244 for information on Control Options 2 Adjustment Range Options: A, B, C, and W are standard set at 1000 psi. D Option is standard set at 400 psi. E Option is standard set at 200 psi. S Option is standard set at 100 psi. Customer may specify pressure setting. US Selected Assemblies Catalogue #999-901-192 TWO PORT RELIEF TECHNICAL TIPS / PERFORMANCE CURVES Relief Valves, Pilot Operated Performance Curves Typical Pressure Rise RPEC-L*N 5000 5000 4000 4000 P = psi P = psi RPCC-L*N 3000 2000 3000 2000 1000 1000 0 5 10 20 15 25 0 Flow = GPM RPGC-L*N 10 20 30 80 120 40 Flow = GPM 50 RPIC-L*N 5000 5000 4000 4000 P = psi P = psi Applications These relief cartridges are normally closed, pressure control elements that are fully adjustable over a wide range of operating pressures up to 5000 psi. They are typically used when accurate pressure regulation is required and spool leakage is not critical. Design Concepts and Features ■ Incorporates 150 micron stainless steel screen to protect the main stage control orifice. ■ Low leakage, 2 to 5 in.3/min./1000 psi, dependent on frame size. ■ Low hysteresis, less than ± 1% ■ Selection of spring adjustment ranges with low adjustment effort. 3000 2000 3000 2000 1000 1000 0 20 RPKC-L*N 40 60 80 100 160 240 320 400 Flow = GPM 0 40 Flow = GPM 160 200 P = psi 5000 4000 3000 2000 1000 0 80 Flow = GPM Relief Valves, Direct Acting Typical Pressure Rise RDDA-L*N 5000 5000 4000 4000 P = psi P = psi RDBA-L*N 3000 2000 1000 3000 2000 1000 0 2 4 6 8 Flow = GPM 10 12 RDFA-L*N 0 4000 P = psi 5000 4000 3000 2000 ■ 0 20 40 60 80 100 160 240 320 400 Flow = GPM 0 RDJA-L*N 5000 4000 3000 2000 80 Flow = GPM Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at a 4 GPM flow rate. US Selected Assemblies Catalogue #999-901-192 3 80 120 40 50 2000 General Application Requirements ■ 30 1000 0 ■ 20 Flow = GPM 3000 1000 ■ 10 RDHA-L*N 5000 1000 P = psi Note: For both types of relief cartridge, any pressure at port 2 is directly additive to the valve settings. In situations where absolute pressure at port 1 is required; use RS*C-*** sequence cartridge or RV*D, four port relief cartridge. Performance Curves P = psi Applications This patented, direct acting, differential area valve with broad operating characteristics is adjustable to 5000 psi. Because of its exceptional performance, this relief cartridge should be considered for applications where fast response, dirt tolerance and leakage are critical. Examples of this type of application would include overshoot protection of fixed and variable volume pumps and shock protection of actuators (cylinders and motors). Design Concepts and Features ■ Maximum leakage is 10 drops/min. at reseat. ■ Reseat equals 90% of cracking pressure for all five frame sizes. ■ Not recommended for repeated adjustment because of high adjustment effort. 40 Flow = GPM 160 200 TWO PORT RELIEF Line Mounted Assemblies TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS (90 DEGREE BODIES) PILOT OPERATED ASSEMBLIES DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-12 GPM Cavity T-162A 1.25 2 .62 0 1 Ports 1 and 2 Assembly Model Code* Ports 1 and 2 Mounting Holes: .28 diameter through hole 1/4” NPTF RPCC-LAN-AAA 2.00 3/8” NPTF RPCC-LAN-AAB 1.72 SAE-4 RPCC-LAN-AAH SAE-6 RPCC-LAN-AAI L Control 1.80 Max. 2 1/4” NPTF RDBA-LAN-AAA 3/8” NPTF RDBA-LAN-AAB SAE-4 RDBA-LAN-AAH SAE-6 RDBA-LAN-AAI 1 .69 Assembly Model Code* 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .28 1.58 0-25 GPM 2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.25 Cavity T-10A 1.50 .75 1 Ports 1 and 2 0 Assembly Model Code* 1/2” NPTF RPEC-LAN-FAC 3/4” NPTF RPEC-LAN-FAD SAE-10 RPEC-LAN-FAK SAE-12 RPEC-LAN-FAL Ports 1 and 2 Mounting Hole: .34 diameter through hole 0 .28 L Control 2.35 Max. 2 1/2” NPTF RDDA-LAN-FAC 3/4” NPTF RDDA-LAN-FAD SAE-10 RDDA-LAN-FAK SAE-12 RDDA-LAN-FAL 1 1.44 Assembly Model Code* 2.25 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 2.12 3.00 0-50 GPM 2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-3A 1.50 .75 1 Ports 1 and 2 0 Assembly Model Code* Ports 1 and 2 Mounting Hole: .42 diameter through hole 1/2” NPTF RPGC-LAN-CAC 0 3/4” NPTF RPGC-LAN-CAD .38 SAE-10 RPGC-LAN-CAK SAE-12 RPGC-LAN-CAL L Control 2.46 Max. 2 1/2” NPTF RDFA-LAN-CAC 3/4” NPTF RDFA-LAN-CAD SAE-10 RDFA-LAN-CAK SAE-12 RDFA-LAN-CAL 1 1.25 Assembly Model Code* 2.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 1.94 3.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 4 US Selected Assemblies Catalogue #999-901-192 TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS (90 DEGREE/90 DEGREE 1.50” SAE C62 FLANGE PORT BODIES) PILOT OPERATED ASSEMBLIES 0-100 GPM 2 DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. G Cavity T-16A 2.25 1.12 1 0 Ports 1 and 2 Assembly Model Code* 3/4” NPTF RPIC-LAN-IAD 1” NPTF RPIC-LAN-IAE 1 1/4” NPTF RPIC-LAN-IAF SAE-12 RPIC-LAN-IAL SAE-16 RPIC-LAN-IAM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1/4 NPTF Gauge Port 1.13 Mounting Hole: .42 diameter through hole 0 1.50 2 G Assembly Model Code* 3/4” NPTF RDHA-LAN-IAD 1” NPTF RDHA-LAN-IAE 1 1/4” NPTF RDHA-LAN-IAF SAE-12 RDHA-LAN-IAL SAE-16 RDHA-LAN-IAM 1 1.88 G 3.00 1.00 0 2.62 0-200 GPM 2 L Control 3.19 Max. Ports 1 and 2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4.00 Cavity T-18A 2.75 1.38 1 0 Ports 1 and 2 Assembly Model Code* 3/4” NPTF RPKC-LAN-LAD 0 1” NPTF RPKC-LAN-LAE .62 1 1/4” NPTF RPKC-LAN-LAF SAE-12 RPKC-LAN-LAL SAE-16 RPKC-LAN-LAM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1/4 NPTF Gauge Port L Control 3.88 Max. 2 G 1 Ports 1 and 2 1 1/2” SAE C62 Assembly Model Code* RPKC-LAN-LA6 RDJA-LAN-LAD 1” NPTF RDJA-LAN-LAE 1 1/4” NPTF RDJA-LAN-LAF SAE-12 RDJA-LAN-LAL SAE-16 RDJA-LAN-LAM G 3.50 0 1.09 2.81 4.62 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-18A 1/4 NPTF Gauge Port 5.00 2.50 Ports 1 and 2 Assembly Model Code* 1 1/2” SAE C62 RDJA-LAN-LA6 0 Mounting Hole: (opposite side) .500 - 13 UNC x 19,0 mm deep. 2 places. 0 L Control 2 3.72 Max. .50 2.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.50 4.00 1 G 0 .62 3.03 4.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 Assembly Model Code* 3/4” NPTF 1 2.12 0-200 GPM 2 Ports 1 and 2 Mounting Hole: .42 diameter through hole 5 TWO PORT RELIEF Line Mounted Assemblies TWO PORT RELIEF Line Mounted Assemblies TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS (THROUGH PORT BODIES) PILOT OPERATED ASSEMBLIES DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-12 GPM Cavity T-162A 1.50 2 1 1 .75 G Ports 1 and 2 Assembly Model Code* 1/4” NPTF RPCC-LAN-AEA 3/8” NPTF RPCC-LAN-AEB SAE-4 RPCC-LAN-AEH SAE-6 RPCC-LAN-AEI *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 Ports 1 and 2 Mounting Holes: (opposite side) .250-25 UNC x .50 deep. 2 places. 1/4 NPTF Gauge Port 0 L Control 2.08 Max. 2 G .75 1/4” NPTF RDBA-LAN-AEA 3/8” NPTF RDBA-LAN-AEB SAE-4 RDBA-LAN-AEH SAE-6 RDBA-LAN-AEI 1 1.50 .88 0 1.83 0-25 GPM Assembly Model Code* *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.50 Cavity T-10A 1.75 2 1 1 G Ports 1 and 2 .88 G G .25 0 Assembly Model Code* 1/4” NPTF Gauge Port. 2 places. 3/8” NPTF RPEC-LAN-FEB 1/2” NPTF RPEC-LAN-FEC SAE-6 RPEC-LAN-FEI SAE-8 RPEC-LAN-FEJ Mounting Holes: (opposite side) .250-20 UNC-2B x .50 deep. 2 places. Ports 1 and 2 0 L Control 2.35 Max. 2 1 .88 Assembly Model Code* 3/8” NPTF RDDA-LAN-FEB 1/2” NPTF RDDA-LAN-FEC SAE-6 RDDA-LAN-FEI SAE-8 RDDA-LAN-FEJ 1.06 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.75 0 .88 1.50 2.06 0-50 GPM Cavity T-3A 2.00 1.75 2 1 1 G Ports 1 and 2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.94 1.00 G .25 0 Assembly Model Code* 1/4 NPTF Gauge Port. 2 places. SAE-8 RPGC-LAN-CEJ SAE-12 RPGC-LAN-CEL Mounting Hole: (opposite side) .250-20 UNC-2B x .50 deep. 0 L Control 2.47 Max. 2 1.25 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports 1 and 2 Assembly Model Code* SAE-8 RDFA-LAN-CEJ SAE-12 RDFA-LAN-CEL 1 G 2.00 0 .75 2.19 3.25 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 6 US Selected Assemblies Catalogue #999-901-192 TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS (THROUGH PORT BODIES) PILOT OPERATED ASSEMBLIES DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-100 GPM 2 Cavity T-16A 3.00 1 1 1.88 G Ports 1 and 2 Assembly Model Code* 1” NPTF RPIC-LAN-IEE 1 1/4” NPTF RPIC-LAN-IEF SAE-12 RPIC-LAN-IEL SAE-16 RPIC-LAN-IEM 0 Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 2 places. 0 .38 L Control 2.39 Max. Assembly Model Code* 1” NPTF RDHA-LAN-IEE 1 1/4” NPTF RDHA-LAN-IEF 1 G 2 1.50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports 1 and 2 1/4 NPTF Gauge Port SAE-12 RDHA-LAN-IEL SAE-16 RDHA-LAN-IEM 1 2.62 3.00 0 1.12 2.38 3.12 0-200 GPM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4.50 Cavity T-18A 3.50 3.00 2 G 1 1 G 1.75 .50 0 Ports 1 and 2 Assembly Model Code* 1” NPTF RPKC-LAN-LEE 1 1/4” NPTF RPKC-LAN-LEF SAE-12 RPKC-LAN-LEL SAE-16 RPKC-LAN-LEM Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 2 places. 1/4 NPTF Gauge Port 0 2 Assembly Model Code* 1” NPTF RDJA-LAN-LEE 1 1/4” NPTF RDJA-LAN-LEF SAE-12 RDJA-LAN-LEL SAE-16 RDJA-LAN-LEM 1 2.12 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 2.78 Max. Ports 1 and 2 3.50 0 1.19 2.75 3.38 5.25 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 7 TWO PORT RELIEF Line Mounted Assemblies TWO PORT RELIEF Line Mounted Assemblies TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS (2.00” SAE C61/C62 FLANGE PORT BODIES 2 CAVITIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-400 GPM DIRECT ACTING ASSEMBLIES Cavity T-18A 4.94 2 2.47 1 Ports 1 and 2 Assembly Model Code* 2” SAE C61 RPKC-LAN-XZY 0 Mounting Holes: .375-16 UNC-2B x .62 deep. 2 places. 0 3.66 Max. 2 .94 Ports 1 and 2 Assembly Model Code* 2” SAE C61 RDJA-LAN-XZY Ports 1 and 2 Assembly Model Code* 2” SAE C62 RDJA-LAN-VTN 1 2.47 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 4.94 0 2.03 4.66 0-400 GPM 6.56 Cavity T-18A 5.94 2 2.97 1 0 Ports 1 and 2 Assembly Model Code* 2” SAE C62 RPKC-LAN-VTN Mounting Holes: .375-16 UNC x .75 deep. 2 places. 0 3.38 Max. 2 1.06 1 2.97 L Control 4.88 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 2.28 4.88 7.12 NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 8 US Selected Assemblies Catalogue #999-901-192 TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS (CROSS-PORT BODIES, 2 CAVITIES) Cross-port relief assemblies are used to protect system components against hydraulic and structural damage which can be caused by the sudden stopping of an inertial load. These assemblies also protect “swing” circuits and other bi-directional installations against possible surges and cavitation. PILOT OPERATED ASSEMBLIES Sun offers a series of cross-port relief assemblies for line mounting which are shown below, as well as a variety of single and dual models in sandwich bodies to simplify circuitry when using ISO 02, ISO 05, ISO 07 and ISO 08 solenoid valves. Go to www.sunhydraulics.com for more product information and pricing. 0-12 GPM 1 DIRECT ACTING ASSEMBLIES Cavity T-162A 1 1.25 2 2 Ports 1 and 2 0 Assembly Model Code* 1/4” NPTF RPCC-LAN-AYA 3/8” NPTF RPCC-LAN-AYB SAE-4 RPCC-LAN-AYH SAE-6 RPCC-LAN-AYI 0 Mounting Holes: .28 diameter through hole 2 places 1 2 Ports 1 and 2 L Control 2.05 Max. Assembly Model Code* 1/4” NPTF RDBA-LAN-AYA 3/8” NPTF RDBA-LAN-AYB SAE-4 RDBA-LAN-AYH SAE-6 RDBA-LAN-AYI 2.05 Max. 1 2 2.50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .70 0 1.38 2.05 0-25 GPM 1 1 2 2 Ports 1 and 2 RPEC-LAN-YFB 1/2” NPTF RPEC-LAN-YFC SAE-6 RPEC-LAN-YFI SAE-8 RPEC-LAN-YFJ Cavity T-10A 1.50 0 Assembly Model Code* 3/8” NPTF 2.75 1 2.31 0 3.50 3.00 .97 1.75 2.53 2 G Assembly Model Code* 3/4” NPTF RPGC-LAN-YCD 1” NPTF RPGC-LAN-YCE 0 SAE-12 RPGC-LAN-YCL 2.00 Max. SAE-16 RPGC-LAN-YCM SAE-6 RDDA-LAN-YFI SAE-8 RDDA-LAN-YFJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.50 G2 2 1 Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 2 places. Ports 1 and 2 RDDA-LAN-YFB RDDA-LAN-YFC 2 1 .50 0 3/8” NPTF 1/2” NPTF Cavity T-3A G1 2 Assembly Model Code* 2 1 0-50 GPM 1 L Control 2.26 Max. 2 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1 Ports 1 and 2 Mounting Holes: .34 diameter through hole. 2 places. 2.26 Max. .44 G *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.75 1/4” NPTF Gauge Ports L Control Ports 1 and 2 Assembly Model Code* 3/4” NPTF RDFA-LAN-YCD 1” NPTF RDFA-LAN-YCE SAE-12 RDFA-LAN-YCL SAE-16 RDFA-LAN-YCM 2.00 Max. 3.50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: 0 1.44 2.94 4.44 5.88 Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 9 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. TWO PORT RELIEF Line Mounted Assemblies TWO PORT RELIEF Line Mounted Assemblies TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS (CROSS-PORT/CROSS-PORT, 1.50” SAE C61/C62 FLANGE PORT BODIES, 2 CAVITIES) PILOT OPERATED ASSEMBLIES 0-100 GPM G 1 DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. Cavity T-16A 1 4.00 3.50 2 1 G2 G1 2 2 Ports 1 and 2 Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 2 places. Assembly Model Code* 1 1/4” NPTF RPIC-LAN-YIF SAE-20 RPIC-LAN-YIN 2 1 .50 0 G Ports 1 and 2 1 1/4” NPTF RDHA-LAN-YIF SAE-20 RDHA-LAN-YIN 1/4” NPTF Gauge Ports 0 Assembly Model Code* L Control 2.69 Max. 2.69 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1 2 0 1.88 3.88 0-200 GPM G 1 4.00 2 G 5.88 7.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-18A 4.94 3.97 1 .97 1 2 G2 G1 2 0 Ports 1 and 2 Assembly Model Code* 1 1/2” SAE C61 RPKC-LAN-YLR Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 2 places. 1/4” NPTF Gauge Ports 0 Ports 1 and 2 Assembly Model Code* 1 1/2” SAE C61 RDJA-LAN-YLR L Control 3.63 Max. 3.63 Max. 5.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1 2 4.00 0-200 GPM G 1 2.00 0 5.94 5.47 6.00 2 G1 2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-18A 1 G 8.00 G2 1 2 .47 0 Ports 1 and 2 Assembly Model Code* 1 1/2” SAE C62 RPKC-LAN-YL6 Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 2 places. 1/4” NPTF Gauge Ports 0 Ports 1 and 2 Assembly Model Code* 1 1/2” SAE C62 RDJA-LAN-YL6 L Control 3.88 Max. 3.88 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 6.00 0 1.88 3.88 5.88 7.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 10 US Selected Assemblies Catalogue #999-901-192 Three Port Relief Assemblies Cartridge Type Page 3 2 Pilot Operated with Vent 12 1 Line Mounted Assemblies (Body Type) 3 2 1 2 1 90 Degree 90 Degree 1.50” SAE C62 Flange Port 90 Degree 2.00” SAE C61/C62 Flange Port, 2 Cavities 14 15 16 Solenoid Operated with Vented Relief Solenoid Operated, Flange Mounted with Vented Relief 17 18 1 G US Selected Assemblies Catalogue #999-901-192 11 THREE PORT RELIEF Relief Valves PILOT OPERATED WITH VENT 3 2 1 7.5 GPM RVBA – LAN T - 163A 1.22 3/4” 2.55 2.63 2.77 15 GPM RVCA – LAN T - 11A 1.38 7/8” 2.50 2.56 2.75 30/35 30 GPM RVEA – LAN T - 2A 1.38 1 1/8” 2.81 2.88 3.06 45/50 60 GPM RVGA – LAN T - 17A 1.81 1 1/4” 3.28 3.31 3.53 150/160 120 GPM RVIA – LAN T - 19A 2.50 1 5/8” 3.94 4.09 4.19 350/375 OPTION ORDERING INFORMATION Full Adjustment 5 Turns + - Nominal Capacity c b 3 Vent Cavity a Control** Adjustment Range Seal B 7.5 GPM* L Standard Screw A 100 - 3000 psi N Buna-N C 15 GPM C Tamper Resistant W 150 - 4500 psi V Viton E 30 GPM K Handknob B 50 - 1500 psi G 60 GPM C 150 - 6000 psi I N 60 - 800 psi 120 GPM Q 60 - 400 psi a Inlet 1 K RV ✱ A – ✱ ✱ ✱ Locating Shoulder 2 Outlet Cartridge Dimensions c b L C Installation Torque (lb. ft.) 25/30 Capacity Typical Cartridge Model Code ** See page 244 for information on Control Options 12 Adjustment Range Options: A, B, C, and W are standard set at 1000 psi. N Option is standard set at 400 psi. Q Option is standard set at 200 psi. * Minimum setting 75 psi on all ranges. Customer may specify pressure setting. US Selected Assemblies Catalogue #999-901-192 THREE PORT RELIEF TECHNICAL TIPS / PERFORMANCE CURVES Relief Valves, Pilot Operated with Vent Typical Pressure Rise Vented Pressure RVBA-L*N 200 5000 P = psi P = psi 4000 3000 2000 1000 0 2 RVCA-L*N 4 6 Flow = GPM 8 100 A, B, C, N, Q & W 50 0 2 4 6 8 10 12 16 20 24 32 40 48 64 80 Flow = GPM 200 5000 4000 P = psi P = psi 150 10 3000 2000 1000 0 5 10 15 Flow = GPM 20 150 C&W 100 A B, N, Q 50 25 0 4 8 Flow = GPM RVEA-L*N 5000 200 4000 150 P = psi Note: Any pressure at port 2 is additive to the pressure setting of the valve. If absolute system pressure must be regulated at port 1 and variable pressure is present at port 2, consider using the 4 port RV*D-*** series where an independent drain port is provided. Performance Curves P = psi Applications Ventable, pilot operated relief valves incorporate an additional port for remote control. ■ To provide remote adjustment of the main cartridge through the use of the RBAC-*** pilot cartridge or other suitable device. ■ To unload the main relief valve by opening the vent port with a 2-way solenoid valve (DAAA-***). Normal relief operation is activated by blocking the bypass pilot flow. Design Concepts and Features ■ Incorporates 150 micron stainless steel screen to protect the main stage control orifice. ■ Low leakage, 2 to 5 in.3/min./1000 psi, dependent on frame size. ■ Control pilot flow .05 to .07 GPM, dependent on frame size. ■ Low hysteresis, less than ± 1% ■ Low pressure drop when unloaded. 3000 2000 1000 0 10 20 30 Flow = GPM 40 100 C&W A 50 50 B, N, Q 0 8 16 Flow = GPM RVGA-L*N 200 5000 P = psi P = psi 4000 3000 2000 1000 0 20 40 60 Flow = GPM 80 150 C&W 100 A B, N, Q 50 100 0 16 32 Flow = GPM 5000 200 4000 150 P = psi P = psi RVIA-L*N 3000 2000 C&W 100 A B, N, Q 50 1000 0 20 40 60 Flow = GPM 80 100 0 32 General Application Requirements ■ ■ ■ ■ Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at a 4 GPM flow rate. US Selected Assemblies Catalogue #999-901-192 13 64 96 Flow = GPM 128 160 THREE PORT RELIEF Line Mounted Assemblies THREE PORT PRESSURE REGULATING RELIEF APPLICATIONS (90 DEGREE BODIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-7.5 GPM Cavity T-163A 3 2 1.00 .50 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 1/4” NPTF 1/4” NPTF RVBA-LAN-JCA 3/8” NPTF 1/4” NPTF RVBA-LAN-JCB SAE-4 SAE-4 RVBA-LAN-JCH SAE-6 SAE-4 RVBA-LAN-JCI Mounting Holes: .28 diameter through hole 2 places. 0 .28 L Control 1.91 Max. 2 1 .97 3 2.00 1.31 0 2.14 2.59 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-15 GPM Cavity T-11A 3 1.25 2 .62 0 1 Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF RVCA-LAN-ECB 1/2” NPTF 1/4” NPTF RVCA-LAN-ECC SAE-4 SAE-4 RVCA-LAN-ECH SAE-6 SAE-6 RVCA-LAN-ECI SAE-8 SAE-6 RVCA-LAN-ECJ Mounting Holes: .34 diameter through hole 2 places. .44 2.56 0 .38 L Control 1.81 Max. 2 1 1.25 3 2.50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.56 0 2.53 3.00 0-30 GPM 3 2 Cavity T-2A 1.50 .75 0 1 Ports 1 and 2 Port 3 Assembly Model Code* 1/2” NPTF 1/4” NPTF RVEA-LAN-BCC 3/4” NPTF 1/4” NPTF RVEA-LAN-BCD SAE-6 SAE-6 RVEA-LAN-BCI SAE-8 SAE-6 RVEA-LAN-BCJ Mounting Holes: .42 diameter through hole 2 places. .50 2.75 0 L Control 2.00 Max. 2 .50 1 1.62 3 3.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 1.72 2.66 3.25 NOTES: Page 12 for cartridge model RV*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 14 US Selected Assemblies Catalogue #999-901-192 THREE PORT PRESSURE REGULATING RELIEF APPLICATIONS (90 DEGREE/90 DEGREE 1.50” SAE C62 FLANGE PORT BODIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-60 GPM 3 Cavity T-17A 2.25 2 2.12 0 1 Ports 1 and 2 Port 3 Assembly Model Code* 3/4” NPTF 1/4” NPTF RVGA-LAN-HCD 1” NPTF 1/4” NPTF RVGA-LAN-HCE 1 1/4” NPTF 1/4” NPTF RVGA-LAN-HCF SAE-12 SAE-6 RVGA-LAN-HCL SAE-16 SAE-6 RVGA-LAN-HCM Mounting Holes: .42 diameter through hole 2 places. .75 3.50 0 L Control 2.16 Max. 2 .75 1 2.00 3 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4.00 2.12 0 0-120 GPM 3 3.50 4.25 Cavity T-19A 3.00 2 1.50 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF RVIA-LAN-KCE 1 1/4” NPTF 1/4” NPTF RVIA-LAN-KCF SAE-20 SAE-6 RVIA-LAN-KCN Mounting Holes: .42 diameter through hole 2 places. .50 0 .50 4.50 L Control 2.78 Max. 2 1 2.25 3 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.47 0 0-120 GPM 3 4.25 5.00 Cavity T-19A 4.50 2 2.25 1 0 Ports 1 and 2 1 1/2” SAE C62 Port 3 SAE-6 Assembly Model Code* RVIA-LAN-KC6 0 .47 Mounting Holes: .375-16 UNC-2B x .62 deep. 2 places. 1 2.47 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 2.78 Max 2 3 4.47 4.94 0 2.41 4.19 4.94 NOTES: Page 12 for cartridge model RV*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 15 THREE PORT RELIEF Line Mounted Assemblies THREE PORT RELIEF Line Mounted Assemblies THREE PORT PRESSURE REGULATING RELIEF APPLICATIONS (90 DEGREE 2.00” SAE C61/C62 FLANGE PORT BODIES, 2 CAVITIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-240 GPM 3 Cavity T-19A 5.94 2 2.97 1 Ports 1 and 2 Port 3 Assembly Model Code* 2” SAE C61 SAE-6 RVIA-LAN-XZZ 0 Mounting Holes: .50-13 UNC-2B x .87 deep. 2 places. 0 2 .97 2.77 Max. 3 1 2.88 4.97 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.94 0 1.97 0-240 GPM 3 4.25 6.03 6.75 Cavity T-19A 5.94 2 2.97 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 2” SAE C62 SAE-6 RVIA-LAN-Z8Z Mounting Holes: .500-13 UNC-2B x .87 deep. 2 places. L Control 0 2.78 Max. 1.06 2 1 2.97 3 4.88 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.94 0 2.26 4.97 6.78 7.50 NOTES: Page 12 for cartridge model RV*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 16 US Selected Assemblies Catalogue #999-901-192 THREE PORT PRESSURE REGULATING RELIEF APPLICATIONS (SOLENOID OPERATED BODIES WITH VENTED RELIEF) Suitable for operation up to 5000 psi PILOT OPERATED ASSEMBLIES 0-15 GPM Solenoid Valve Normally Closed Solenoid Valve Normally Open Go to www.sunhydraulics.com for more product information and pricing. Cavity T-11A RVCA 1 1 L Control 1.82 Max. 2 2 1 2.91 Max. DAAA-M*N 1 G G 3.50 Ports 1 and 2 Assembly Model Code* 1/4” NPTF XRCA-LAN-*A 3/8” NPTF XRCA-LAN-*B 1/2” NPTF XRCA-LAN-*C SAE-6 XRCA-LAN-*I SAE-8 XRCA-LAN-*J 2 1/4 NPTF Gauge Port G 1 2.00 Mounting Holes: .375-16 UNC-2B x .63 deep. .69 0 2.78 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.03 .88 0 0 Assembly Order: 760 – ✱ ✱ ✱ ✱ Port Style / Type See above. DAAA Spool Configuration H Normally Open Coils must be ordered separately. See page 248 for Connector Options Coil Configuration ISO/DIN 206 6 VDC 212 12 VDC 224 24 VDC 211 115 VAC 223 230 VAC C Normally Closed 0-30 GPM Solenoid Valve Normally Closed Solenoid Valve Normally Open 0 Solenoid Coil Order: XRCA – ✱ ✱ ✱ – ✱ See Page 12 for RVCA Options 1.00 2.00 Cavity T-2A RVEA L Control 2.00 Max. 2 2 1 1 2.91 Max. DAAA-M*N 1 1 3.75 G G Ports 1 and 2 Assembly Model Code* 1/4” NPTF XREA-LAN-*A 3/8” NPTF XREA-LAN-*B 1/2” NPTF XREA-LAN-*C 3/4” NPTF XREA-LAN-*D SAE-8 XREA-LAN-*J SAE-12 XREA-LAN-*L .88 1 G 2.12 Mounting Holes: .375-16 UNC-2B x .63 deep. 0 2.50 3.50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.06 2.00 1.00 0 Solenoid Coil Order: XREA – ✱ ✱ ✱ – ✱ See Page 12 for RVEA Options 0 0 Assembly Order: DAAA Spool Configuration H Normally Open 760 – ✱ ✱ ✱ ✱ Port Style / Type See above. C Normally Closed NOTES: Page 12 for cartridge model RV*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 2 1/4 NPTF Gauge Port 17 Coils must be ordered separately. See page 248 for Connector Options Coil Configuration 206 212 224 211 223 ISO/DIN 6 VDC 12 VDC 24 VDC 115 VAC 230 VAC THREE PORT RELIEF Line Mounted Assemblies THREE PORT RELIEF Line Mounted Assemblies THREE PORT PRESSURE REGULATING RELIEF APPLICATIONS (SOLENOID OPERATED, FLANGE MOUNTED BODIES WITH VENTED RELIEF) Suitable for operation up to 5000 psi PILOT OPERATED ASSEMBLIES 0-60 GPM Solenoid Valve Normally Closed Solenoid Valve Normally Open Go to www.sunhydraulics.com for more product information and pricing. Cavity T-17A RVGA 2 2 1 1 1 1 5.00 G G 2.91 Max. L Control 2.37 Max. 1/4 NPTF Gauge Port Ports 1 and 2 Assembly Model Code* 1” SAE C61 XRGA-LAN-*P G 1.75 1.31 1 3.09 2 Mounting Holes: .375-16 UNC-2B x .62 deep. 0 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.62 3.62 4.00 .38 Assembly Order: 760 – ✱ ✱ ✱ ✱ Port Style / Type DAAA Spool Configuration H Normally Open See above. 0 Coils must be ordered separately. See page 248 for Connector Options Coil Configuration 206 212 224 211 223 C Normally Closed 0-120 GPM Solenoid Valve Normally Closed Solenoid Valve Normally Open 1.25 Solenoid Coil Order: XRGA – ✱ ✱ ✱ – ✱ See Page 12 for RVGA Options 2.50 0 ISO/DIN 6 VDC 12 VDC 24 VDC 115 VAC 230 VAC Cavity T-19A RVIA 1 1 L Control 2.78 Approx. 2 2 1 2.88 Max. DAAA-M*N 1 7.62 G G Ports 1 and 2 Assembly Model Code* 2” SAE C61 XRIA-LAN-*S 2” SAE Code 62 5.12 4 Bolt Flange Pattern Typ. (3) Places .375-16 UNC-2B x .88 deep. 2 places 2.38 Mounting Holes: .375-16 UNC-2B x .62 deep. 12 places 0 0 1/4 NPTF Gauge Port G *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.94 5.47 2.97 .47 0 Assembly Order: XRIA – ✱ ✱ ✱ – ✱ See Page 12 for RVIA Options 2.97 0 5.94 Solenoid Coil Order: 760 – ✱ ✱ ✱ ✱ Port Style / Type See above. DAAA Spool Configuration H Normally Open C Normally Closed Coils must be ordered separately. See page 248 for Connector Options Coil Configuration ISO/DIN 206 6 VDC 212 12 VDC 224 24 VDC 211 115 VAC 223 230 VAC NOTES: Page 12 for cartridge model RV*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 18 US Selected Assemblies Catalogue #999-901-192 Sequence Assemblies Cartridge Type Page 3 2 Pilot Operated 20 Direct Acting 20 Direct Acting with Reverse Free Flow Check 28 1 3 2 1 3 2 1 Line Mounted Assemblies (Body Type) 3 2 90 Degree 22 90 Degree with Reverse Free Flow Check 24 90 Degree with Reverse Free Flow Check, 2 Cavities 26 90 Degree 30 1 3 1 2 G VB C2B C2A C1B C1A VA 3 2 1 US Selected Assemblies Catalogue #999-901-192 19 SEQUENCE Sequence Valves PILOT OPERATED 3 2 1 7.5 GPM RSBC – LAN T - 163A 1.22 3/4” 2.55 2.63 2.77 15 GPM RSDC – LAN T - 11A 1.38 7/8” 2.50 2.56 2.75 30/35 30 GPM RSFC – LAN T - 2A 1.38 1 1/8” 2.81 2.88 3.06 45/50 60 GPM RSHC – LAN T - 17A 1.81 1 1/4” 3.28 3.31 3.53 150/160 120 GPM RSJC – LAN T - 19A 2.50 1 5/8” 3.94 4.09 4.19 350/375 OPTION ORDERING INFORMATION Cavity Nominal Capacity c 3 Drain a Control** Adjustment Range Seal B 7.5 GPM* L Standard Screw A 100 - 3000 psi N Buna-N D 15 GPM C Tamper Resistant W 150 - 4500 psi V Viton F 30 GPM K Handknob B 50 - 1500 psi H 60 GPM C 150 - 6000 psi J 120 GPM N 60 - 800 psi Q 60 - 400 psi Locating Shoulder a 2 Sequence K RS ✱ C – ✱ ✱ ✱ Full Adjustment 5 Turns + - b Cartridge Dimensions c b L C Installation Torque (lb. ft.) 25/30 Capacity Typical Cartridge Model Code Adjustment Range Options: A, B, C, and W are standard set at 1000 psi. N Option is standard set at 400 psi. Q Option is standard set at 200 psi. * Minimum setting 75 psi on all ranges. Customer may specify pressure setting. ** See page 244 for information on Control Options Inlet 1 DIRECT ACTING 3 2 Cartridge Dimensions c b L 15 GPM SXCA – LAN T - 11A 1.38 7/8” 3.09 3.15 Installation Torque (lb. ft.) 30/35 30 GPM SXEA – LAN T - 2A 1.38 1 1/8” 3.47 3.53 45/50 Capacity Typical Cartridge Model Code Cavity a C 1 OPTION ORDERING INFORMATION SX ✱ A – ✱ ✱ ✱ Full Adjustment 4 Turns + - Nominal Capacity Control** C 15 GPM L Standard Screw E 30 GPM C Tamper Resistant Seal A 500 - 3000 psi N Buna-N W 800 - 4500 psi V Viton B 300 - 1500 psi c b Adjustment Range C 2000 - 6000 psi D 200 - 800 psi 3 Drain 2 Sequence Inlet 1 Locating Shoulder a ** See page 244 for information on Control Options 20 Adjustment Range Options: A, B, and W are standard set at 1000 psi. C Option is standard set at 2000 psi. D Option is standard set at 400 psi Customer may specify pressure setting. US Selected Assemblies Catalogue #999-901-192 TECHNICAL TIPS / PERFORMANCE CURVES Performance Curves Pressure Drop-full Sequence RSBC-L*N RSDC-L*N 200 150 P = psi P = psi 200 100 50 0 2 4 6 8 150 100 50 10 RSFC-L*N 10 15 20 40 60 80 Flow = GPM RSHC-L*N 200 150 150 P = psi 200 100 50 0 5 0 Flow = GPM P = psi Applications Pilot operated sequence cartridges are similar to relief valves, but with an additional third port, to drain the spring chamber. ■ May be used to regulate pressure more accurately than relief valve, as pressure is regulated on an absolute basis. ■ To control the sequence of two or more cylinders or motors while maintaining the pressure on the actuator that moves first. Design Concepts and Features ■ Exceptionally flat pressure control over a wide range of settings. ■ Low hysteresis and spool leakage: 2 to 5 in.3/min./1000 psi dependent on frame size. ■ Wide selection of spring ranges to optimize adjustment sensitivity. ■ Pilot flow will continue to increase when pilot section opens as pressure at port 1 increases above setting. Maximum Pilot Flow May be 150 in.3/min. SEQUENCE Sequence Valves, Pilot Operated 10 20 30 Flow = GPM 100 40 50 20 0 Flow = GPM RSJC-L*N P = psi 200 150 100 50 0 40 80 120 Flow = GPM 160 Sequence Valves, Direct Acting Performance Curves Pressure Drop-full Sequence SXCA-L*N SXEA-L*N 400 400 300 300 P = psi P = psi Applications The direct acting sequence cartridges are interchangeable with the pilot operated models and may be used as an alternative to the pilot operated version. Design Concepts and Features ■ Low hysteresis and low leakage on closing. Valve reseats with leakage less than 5 drops./min. ■ Reseat at 85% of cracking pressure. ■ Direct acting design provides fast opening and closing. ■ Zero pilot flow (however, the spring chamber drain must not be plugged). See Note. 200 100 0 5 10 15 200 100 0 Note: For both types of sequence cartridge, any pressure at port 3 is directly additive to the valve setting. General Application Requirements ■ ■ ■ ■ Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at a 4 GPM flow rate. US Selected Assemblies Catalogue #999-901-192 21 10 20 30 SEQUENCE Line Mounted Assemblies THREE PORT PRESSURE SEQUENCING APPLICATIONS (90 DEGREE BODIES) PILOT OPERATED ASSEMBLIES DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-7.5 GPM Cavity T-163A 3 2 1.00 .50 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 1/4” NPTF 1/4” NPTF RSBC-LAN-JCA 3/8” NPTF 1/4” NPTF RSBC-LAN-JCB SAE-4 SAE-4 RSBC-LAN-JCH SAE-6 SAE-4 RSBC-LAN-JCI Mounting Holes: .28 diameter through hole 2 places. 0 .28 L Control 1.91 Max. 2 1 .97 3 2.00 1.31 0 2.14 2.59 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-15 GPM Cavity T-11A 3 2 1.25 .62 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF RSDC-LAN-ECB 1/2” NPTF 1/4” NPTF RSDC-LAN-ECC SAE-4 SAE-4 RSDC-LAN-ECH SAE-6 SAE-6 RSDC-LAN-ECI SAE-8 SAE-6 RSDC-LAN-ECJ Mounting Holes: .34 diameter through hole 2 places. 0 .38 L Control 2.40 Max. 2 1 1.25 3 Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF SXCA-LAN-ECB 1/2” NPTF 1/4” NPTF SXCA-LAN-ECC SAE-4 SAE-4 SXCA-LAN-ECH SAE-6 SAE-6 SXCA-LAN-ECI SAE-8 SAE-6 SXCA-LAN-ECJ 2.50 1.56 0 2.53 3.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-30 GPM Cavity T-2A 3 2 1.50 .75 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 3/4” NPTF 1/4” NPTF RSFC-LAN-BCD SAE-6 SAE-6 RSFC-LAN-BCI SAE-8 SAE-6 RSFC-LAN-BCJ SAE-12 SAE-6 RSFC-LAN-BCL 0 Mounting Holes: .42 diameter through hole 2 places. L Control 2.66 Max. 2 .50 1 1.62 Ports 1 and 2 Port 3 Assembly Model Code* 3/4” NPTF 1/4” NPTF SXEA-LAN-BCD SAE-6 SAE-6 SXEA-LAN-BCI SAE-8 SAE-6 SXEA-LAN-BCJ SAE-12 SAE-6 SXEA-LAN-BCL 3 3.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 1.72 2.66 3.25 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 20 for cartridge models RS*C-*** and SX*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 22 US Selected Assemblies Catalogue #999-901-192 THREE PORT PRESSURE SEQUENCING APPLICATIONS (90 DEGREE BODIES) PILOT OPERATED ASSEMBLIES 3 Go to www.sunhydraulics.com for more product information and pricing. 0-60 GPM Cavity T-17A 2.25 2 2.12 0 1 Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF RSHC-LAN-HCE 1 1/4” NPTF 1/4” NPTF RSHC-LAN-HCF SAE-12 SAE-6 RSHC-LAN-HCL SAE-16 SAE-6 RSHC-LAN-HCM 0 Mounting Holes: .42 diameter through hole 2 places. L Control 2.16 Max. 2 .75 1 2.00 3 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.12 0 0-120 GPM 3.50 4.25 Cavity T-19A 3 3.00 2 1.50 1 Ports 1 and 2 0 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF RSJC-LAN-KCE 1 1/4” NPTF 1/4” NPTF RSJC-LAN-KCF Mounting Holes: .42 diameter through hole 2 places. 0 .50 L Control 2.78 Max. 2 1 2.25 3 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 2.47 4.25 5.00 NOTES: Page 20 for cartridge models RS*C-*** and SX*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 23 SEQUENCE Line Mounted Assemblies SEQUENCE Line Mounted Assemblies THREE PORT PRESSURE SEQUENCING APPLICATIONS (BODIES WITH REVERSE FREE FLOW CHECK) PILOT OPERATED ASSEMBLIES DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-7.5 GPM Cavity T-163A 3 1 2 .70 2.56 1.00 G 0 Mounting Holes: .28 diameter through hole, 2 places. Ports 1 and 2 Port 3 Assembly Model Code* 1/4” NPTF 1/4” NPTF RSBC-LAN-J6* 3/8” NPTF 1/4” NPTF RSBC-LAN-J6* SAE-4 SAE-4 RSBC-LAN-J6* SAE-6 SAE-4 RSBC-LAN-J6* 0 .25 L Control 1.92 Max. 3 1 CXAD-XCN .63 G 2 3.00 1.50 0 3.00 1/4 NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-15 GPM Cavity T-11A 3 1 2 1.25 G Ports 1 and 2 Port 3 0 CXDA-XCN Assembly Model Code* 1/4 NPTF Gauge Port Mounting Holes: .34 diameter through hole, 2 places. 0 3/8” NPTF 1/4” NPTF RSDC-LAN-E6B 1/2” NPTF 1/4” NPTF RSDC-LAN-E6C 1.00 SAE-6 SAE-6 RSDC-LAN-E6I 1.50 SAE-8 SAE-6 RSDC-LAN-E6J SAE-10 SAE-6 RSDC-LAN-E6K L Control 2.28 Max. 3 1 G 2 .59 3.00 0 .91 2.06 Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF SXCA-LAN-E6B 1/2” NPTF 1/4” NPTF SXCA-LAN-E6C SAE-6 SAE-6 SXCA-LAN-E6I SAE-8 SAE-6 SXCA-LAN-E6J SAE-10 SAE-6 SXCA-LAN-E6K 3.03 3.62 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-30 GPM Cavity T-2A 3 1 2 1.50 G Ports 1 and 2 Port 3 0 CXFA-XCN Assembly Model Code* Mounting Holes: .28 diameter through hole, 2 places. 3/8” NPTF 1/4” NPTF RSFC-LAN-B6B 0 2.75 1/2” NPTF 1/4” NPTF RSFC-LAN-B6C 2.00 3/4” NPTF 1/4” NPTF RSFC-LAN-B6D SAE-8 SAE-6 RSFC-LAN-B6J SAE-10 SAE-6 RSFC-LAN-B6K 1/4 NPTF Gauge Port 1 G .66 3.00 0 .81 1.00 2.19 L Control 2.39 Max. 3 2 3.56 Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF SXEA-LAN-B6B 1/2” NPTF 1/4” NPTF SXEA-LAN-B6C 3/4” NPTF 1/4” NPTF SXEA-LAN-B6D SAE-8 SAE-6 SXEA-LAN-B6J SAE-10 SAE-6 SXEA-LAN-B6K 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 20 for cartridge models RS*C-*** and SX*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 24 US Selected Assemblies Catalogue #999-901-192 THREE PORT PRESSURE SEQUENCING APPLICATIONS (BODIES WITH REVERSE FREE FLOW CHECK) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-60 GPM Cavity T-17A 3 1 2 1.25 G 0 CXDA-XCN 1/4” NPTF Gauge Port Mounting Holes: .34 diameter through hole, 2 places. Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF RSHC-LAN-H6E 1 1/4” NPTF 1/4” NPTF RSHC-LAN-H6F 1.00 SAE-12 SAE-6 RSHC-LAN-H6L 1.50 SAE-16 SAE-6 RSHC-LAN-H6M 0 L Control 2.28 Max. 3 1 G 2 .59 3.00 .91 0 2.06 3.03 3.62 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-120 GPM Cavity T-19A 3 1 2 1/4 NPTF Gauge Port CXJA-XCN 0 G 3.00 Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF RSJC-LAN-K6E 1 1/4” NPTF 1/4” NPTF RSJC-LAN-K6F Mounting Holes: .42 diameter through hole, 2 places. 6.00 1 4.00 1.43 2.72 Max. 3 G L Control 2 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .50 1.88 4.41 6.22 7.00 NOTES: Page 20 for cartridge models RS*C-*** and SX*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 25 SEQUENCE Line Mounted Assemblies SEQUENCE Line Mounted Assemblies THREE PORT DUAL PRESSURE SEQUENCING APPLICATIONS (2 CAVITY BODIES WITH REVERSE FREE FLOW CHECKS) The line-mounted dual sequencing assembly can be used in applications where two hydraulic cylinders are to be operated in a particular sequence when both extending and retracting. The block eliminates a great deal of pipework when compared to using conventional line mounted valves. PILOT OPERATED ASSEMBLIES 0-15 GPM C2B C2A Cavity T-11A VB 2.50 C1B C1B C1A DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. VA CXDA-XCN 2 places. C2B C1A C2A 0 All Ports Assembly Model Code* 3/8” NPTF RSDC-LAN-E8B 1/2” NPTF RSDC-LAN-E8C SAE-6 RSDC-LAN-E8I SAE-8 RSDC-LAN-E8J All Ports Mounting Holes: .34 diameter through hole 2 places. 0 .31 2.41 L Control 2.41 Max. VA VB 1.06 2.94 Assembly Model Code* 3/8” NPTF SXCA-LAN-E8B 1/2” NPTF SXCA-LAN-E8C SAE-4 SXCA-LAN-E8I SAE-6 SXCA-LAN-E8J 2.50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 0-30 GPM C2B C2A C1B C1A VB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4.00 Cavity T-2A 3.00 C1 B C1 A VA CXFA-XCN 2 places. C2 B C2 A 0 All Ports Assembly Model Code* 1/2” NPTF RSFC-LAN-B8C 3/4” NPTF RSFC-LAN-B8D SAE-8 RSFC-LAN-B8J .25 0 All Ports Mounting Holes: .34 diameter through hole 2 places. L Control 2.75 Max. 2.75 VA Assembly Model Code* 1/2” NPTF SXEA-LAN-B8C 3/4” NPTF SXEA-LAN-B8D SAE-8 SXEA-LAN-B8J VB 3.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.06 0 3.31 0-60 GPM C2B C2A C1B C1A VB 4.00 Cavity T-17A 5.00 C1B VA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. C1A CXHA-XCN 2 places. C2B C2A 0 All Ports Assembly Model Code* 1” NPTF RSHC-LAN-H8E 1 1/4” NPTF RSHC-LAN-H8F Mounting Holes: (opposite side) .42 diameter through hole, 2 places. 0 L Control VA 2.28 Max. 2.28 VB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.00 0 1.56 4.56 6.12 NOTES: Page 20 for cartridge models RS*C-*** and SX*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 26 US Selected Assemblies Catalogue #999-901-192 US Selected Assemblies Catalogue #999-901-192 SEQUENCE NOTES 27 SEQUENCE Sequence Valves DIRECT ACTING WITH REVERSE FREE FLOW CHECK 3 Capacity 2 1 a C Installation Torque (lb. ft.) 35/30 15 GPM SCCA – LAN T - 11A 1.38 7/8” 3.09 3.15 SCEA – LAN T - 2A 1.38 1 1/8” 3.47 3.53 45/50 60 GPM SCGA – LAN T - 17A 1.81 1 1/4” 3.94 4.00 150/160 120 GPM SCIA – LAN T - 19A 2.50 1 5/8” 4.72 4.92 350/375 Full Adjustment 4 Turns + - Nominal Capacity c Cavity Cartridge Dimensions c b L 30 GPM OPTION ORDERING INFORMATION b Typical Cartridge Model Code SC ✱ A – ✱ ✱ ✱ Control** Adjustment Range Seal C 15 GPM L Standard Screw A 500 - 3000 psi N Buna-N E 30 GPM C Tamper Resistant W 800 - 4500 psi V Viton G 60 GPM B 300 - 1500 psi I D 200 - 800 psi 120 GPM C 2000 - 6000 psi 3 Drain 2 Sequence Inlet 1 Locating Shoulder a ** See page 244 for information on Control Options 28 Adjustment Range Options: A, B and W are standard set at 1000 psi. C Option is standard set at 2000 psi. D Option is standard set at 400 psi. Customer may specify pressure setting. US Selected Assemblies Catalogue #999-901-192 TECHNICAL TIPS / PERFORMANCE CURVES Performance Curves Pressure Drop-full Sequence Reverse Free Flow SCCA-L*N 300 P = psi P = psi 300 200 100 0 3 6 9 12 Flow = GPM 200 100 15 0 3 0 6 6 9 12 15 12 18 24 30 24 36 48 60 48 72 96 120 Flow = GPM SCEA-L*N 300 P = psi 300 P = psi Applications SC*A series of sequence valves have an integral reverse free flow check and may be used in a similar manner to the cartridges without the check. Design Concepts and Features ■ This is a zero pilot flow valve. Port 3 must not be plugged. ■ Pressure at Port 3 is directly additive to valve setting. ■ Typical response time is 2 ms. ■ Maximum leakage is 10 drops/min. at reseat. ■ Reseat exceeds 85% of set pressure. ■ Reverse free flow check cracking pressure is 20 psi to 45 psi, depending on frame size. SEQUENCE Sequence Valves, Reverse Free Flow Check 200 100 0 6 12 18 24 Flow = GPM 200 100 30 Flow = GPM SCGA-L*N 300 P = psi P = psi 300 200 100 0 12 24 36 48 Flow = GPM 200 100 0 60 12 Flow = GPM SCIA-L*N 300 P = psi P = psi 300 200 100 0 24 48 72 Flow = GPM 96 120 200 100 0 General Application Requirements ■ ■ ■ ■ Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at a 4 GPM flow rate. US Selected Assemblies Catalogue #999-901-192 29 24 Flow = GPM SEQUENCE Line Mounted Assemblies THREE PORT PRESSURE SEQUENCING APPLICATIONS (90 DEGREE BODIES) DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 3 0-15 GPM Cavity T-11A 2 1.25 .62 1 0 Mounting Holes: .34 diameter through hole 2 places. 0 .38 L Control 2.40 Max. 2 1 1.25 3 Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF SCCA-LAN-ECB 1/2” NPTF 1/4” NPTF SCCA-LAN-ECC SAE-4 SAE-4 SCCA-LAN-ECH SAE-6 SAE-6 SCCA-LAN-ECI SAE-8 SAE-6 SCCA-LAN-ECJ 2.50 1.56 0 3 2 2.53 3.00 0-30 GPM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-2A 1.50 .75 1 0 0 Mounting Holes: .42 diameter through hole 2 places. L Control 2.66 Max. 2 .50 1 1.62 3 Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF SCEA-LAN-BCB 1/2” NPTF 1/4” NPTF SCEA-LAN-BCC 3/4” NPTF 1/4” NPTF SCEA-LAN-BCD SAE-6 SAE-6 SCEA-LAN-BCH SAE-8 SAE-6 SCEA-LAN-BCI 3.00 0 1.72 2.66 3.25 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 28 for cartridge model SC*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 30 US Selected Assemblies Catalogue #999-901-192 THREE PORT PRESSURE SEQUENCING APPLICATIONS (90 DEGREE BODIES) DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 3 0-60 GPM Cavity T-17A 2.25 2 2.12 0 1 Mounting Holes: .42 diameter through hole 2 places. 0 2 .75 Ports 1 and 2 L Control 2.82 Max. 1 2.00 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF SCGA-LAN-HCE 1 1/4” NPTF 1/4” NPTF SCGA-LAN-HCF SAE-12 SAE-6 SCGA-LAN-HCL SAE-16 SAE-6 SCGA-LAN-HCM 3 4.00 2.12 0 3 0-120 GPM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.50 4.25 Cavity T-19A 3.00 2 1.50 1 0 0 .50 Mounting Holes: .42 diameter through hole 2 places. Ports 1 and 2 L Control 3.56 Max. 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF SCIA-LAN-KCE 1 1/4” NPTF 1/4” NPTF SCIA-LAN-KCF 1 2.25 3 4.00 0 2.47 4.25 5.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 28 for cartridge model SC*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 31 SEQUENCE Line Mounted Assemblies SEQUENCE NOTES 32 US Selected Assemblies Catalogue #999-901-192 Pressure Reducing Assemblies Cartridge Type Page 3 2 Pilot Operated 34 1 Line Mounted Assemblies (Body Type) 3 2 90 Degree 36 90 Degree 1.50” SAE C61/C62 Flange Port 38 90 Degree with Reverse Free Flow Check 39 G 1 3 2 G 1 3 2 1 G US Selected Assemblies Catalogue #999-901-192 33 PRESSURE REDUCING Pressure Reducing Valves PILOT OPERATED REDUCING 3 2 1 5 GPM PBBB – LAN T - 163A 1.22 3/4” 2.55 2.63 2.77 10 GPM PBDB – LAN T - 11A 1.38 7/8” 2.50 2.56 2.75 30/35 20 GPM PBFB – LAN T - 2A 1.38 1 1/8” 2.81 2.88 3.06 45/50 40 GPM PBHB – LAN T - 17A 1.81 1 1/4” 3.28 3.31 3.53 150/160 80 GPM PBJB – LAN T - 19A 2.50 1 5/8” 3.94 4.09 4.19 350/375 OPTION ORDERING INFORMATION Full Adjustment 5 Turns + - Nominal Capacity b c 3 Drain 2 Inlet Locating Shoulder Cavity a K PB ✱ B – ✱ ✱ ✱ Control** Adjustment Range Seal B 5 GPM* L Standard Screw A 100 - 3000 psi N Buna-N D 10 GPM C Tamper Resistant W 150 - 4500 psi V Viton F 20 GPM K Handknob B 50 - 1500 psi H 40 GPM N 60 - 800 psi J 80 GPM Q 60 - 400 psi a 1 Reduced Pressure Cartridge Dimensions c b L C Installation Torque (lb. ft.) 25/30 Capacity Typical Cartridge Model Code ** See page 244 for information on Control Options 34 Adjustment Range Options: All are standard set at 200 psi. Maximum pressure differentials for spring ranges: A and B are 3000 psi. N and Q are 2000 psi. W is 5000 psi inlet pressure. * Minimum setting 75 psi on all ranges. Customer may specify pressure setting. US Selected Assemblies Catalogue #999-901-192 PRESSURE REDUCING TECHNICAL TIPS / PERFORMANCE CURVES Pressure Reducing Valves, Pilot Operated No Load Pressure Drop with Valve Full Open Regulated Pressure 200 2000 150 1500 P = psi P = psi PBBB-L*N 100 50 0 1 2 3 4 Flow = GPM 1000 500 0 5 2.50 5 7.5 5 10 15 10 20 30 Flow = GPM 200 2000 150 1500 P = psi P = psi PBDB-L*N 100 50 0 2 4 6 8 Flow = GPM 1000 500 0 10 Flow = GPM PBFB-L*N 200 2000 150 1500 P = psi Note: Sun also offers reducing/relieving cartridges (PP*B) that are functionally interchangeable with reducing cartridges. However, with the reducing/relieving valves it is necessary to have a full flow capacity return passage from port 3. See page 42 for further details. Performance Curves P = psi Applications Pilot operated reducing cartridges reduce high primary pressure at port 2 (inlet) to a controlled lower pressure at port 1. Port 3 is the pilot drain connection and pressure in this port is directly additive to the reduced pressure setting. ■ Provide a controlled lower pressure to a secondary circuit function. ■ Provide accurate reduced pressure control for clamp and hold down circuits. Design Concepts and Features ■ Low hysteresis for accurate pressure regulation. ■ High flow capacity relative to physical size. ■ Low pilot flow (from 7 to 20 in.3/min.) dependent on frame size. ■ Incorporates a 150 micron screen to protect main stage control orifice from contamination. ■ Multiple spring ranges for optimum adjustment control. ■ See page 34 for maximum operating pressure differentials for individual spring ranges. 100 50 0 5 10 15 Flow = GPM 1000 500 20 0 Flow = GPM 200 2000 150 1500 P = psi P = psi PBHB-L*N 100 50 0 10 20 30 Flow = GPM 1000 500 40 0 10 20 30 40 40 60 80 Flow = GPM 50 60 200 2000 150 1500 P = psi P = psi PBJB-L*N 100 50 0 20 40 60 Flow = GPM 80 1000 500 0 20 General Application Requirements ■ ■ ■ ■ Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at zero flow rate. US Selected Assemblies Catalogue #999-901-192 35 Flow = GPM 100 120 PRESSURE REDUCING Line Mounted Assemblies THREE PORT PRESSURE REDUCING APPLICATIONS (90 DEGREE BODIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 3 2 0-5 GPM Cavity T-163A 1.00 G .50 0 1 Mounting Holes: .28 diameter through hole 2 places. Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF PBBB-LAN-JFB SAE-4 SAE-4 PBBB-LAN-JFH SAE-6 SAE-4 PBBB-LAN-JFI 0 .28 L Control 1.91 Max. 2 1 .97 3 G 2.00 1.31 .59 0 2.14 2.59 1/4 NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3 G .62 0 1 Mounting Holes: .34 diameter through hole, 2 places. Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF PBDB-LAN-EFB 1/2” NPTF 1/4” NPTF PBDB-LAN-EFC SAE-4 SAE-4 PBDB-LAN-EFH SAE-6 SAE-6 PBDB-LAN-EFI SAE-8 SAE-6 PBDB-LAN-EFJ 0 1 1.25 3 G 2.50 0 3 L Control 1.81 Max. 2 .38 .81 1.56 2.53 3.00 1/4 NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-20 GPM Cavity T-2A 1.50 2 G .75 0 1 Ports 1 and 2 Cavity T-11A 1.25 2 Ports 1 and 2 0-10 GPM Mounting Holes: .42 diameter through hole, 2 places. Port 3 Assembly Model Code* 1/2” NPTF 1/4” NPTF PBFB-LAN-BFC 3/4” NPTF 1/4” NPTF PBFB-LAN-BFD SAE-10 SAE-6 PBFB-LAN-BFK SAE-12 SAE-6 PBFB-LAN-BFL 0 L Control 2.00 Max. 2 .50 1 1.62 3 G 3.00 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .75 1.72 2.66 3.25 1/4 NPTF Gauge Port NOTES: Page 34 for cartridge model PB*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 36 US Selected Assemblies Catalogue #999-901-192 THREE PORT PRESSURE REDUCING APPLICATIONS (90 DEGREE BODIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-40 GPM Cavity T-17A 3 2 2.25 G 1 1.12 0 Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF PBHB-LAN-HFE 1 1/4” NPTF 1/4” NPTF PBHB-LAN-HFF SAE-12 SAE-6 PBHB-LAN-HFL SAE-16 SAE-6 PBHB-LAN-HFM 1/4 NPTF Gauge Port Mounting Holes: .42 diameter through hole, 2 places. 0 L Control 2.15 Max. 2 .75 1 2.00 3 G 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.03 0 2.12 3.44 4.25 0-80 GPM Cavity T-19A 3 3.00 2 G 1.50 1 0 1/4 NPTF Gauge Port Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF PBJB-LAN-KFE 1 1/4” NPTF 1/4” NPTF PBJB-LAN-KFF Mounting Holes: .42 diameter through hole. 2 places. 0 .50 L Control 2.78 Max. 2 1 2.25 3 G 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 1.00 2.47 4.25 5.00 NOTES: Page 34 for cartridge model PB*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 37 PRESSURE REDUCING Line Mounted Assemblies PRESSURE REDUCING Line Mounted Assemblies THREE PORT PRESSURE REDUCING APPLICATIONS (90 DEGREE, 1.50” SAE C61/C62 FLANGE PORT BODIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-80 GPM Cavity T-19A 3 4.00 2 G 2.00 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 1 1/2” SAE C61 SAE-6 PBJB-LAN-KFR 1/4 NPTF Gauge Port Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep, 2 places. 0 .47 L Control 2.78 Max. 2 1.97 3.47 3.94 1 0 .75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3 G 2.19 0-80 GPM 3 4.50 G 2.25 4.00 4.75 Cavity T-19A 2 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 1 1/2” SAE C62 SAE-6 PBJB-LAN-KF6 1/4 NPTF Gauge Port Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep, 2 places 0 .47 2.78 Max. 2 2.47 4.47 4.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1 G 0 .75 L Control 3 2.41 4.19 4.94 NOTES: Page 34 for cartridge model PB*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 38 US Selected Assemblies Catalogue #999-901-192 THREE PORT PRESSURE REDUCING APPLICATIONS (BODIES WITH REVERSE FREE FLOW CHECK) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-5 GPM Cavity T-163A 3 1.00 1 2 G 0 Mounting Holes: .28 diameter through hole, 2 places. 1.50 Ports 1 and 2 Port 3 Assembly Model Code* 1/4” NPTF 1/4” NPTF PBBB-LAN-J2A 3/8” NPTF 1/4” NPTF PBBB-LAN-J2B SAE-4 SAE-4 PBBB-LAN-J2H SAE-6 SAE-4 PBBB-LAN-J2I 0 .25 L Control 1.92 Max. 3 1 CXBA-XCN .75 G 2 .70 1.73 2.75 3.00 0 2.56 3.00 1/4 NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-10 GPM Cavity T-11A 3 1.25 1 2 G Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF PBDB-LAN-E6B 1/2” NPTF 1/4” NPTF PBDB-LAN-E6C SAE-6 SAE-4 PBDB-LAN-E6I SAE-8 SAE-6 PBDB-LAN-E6J 0 CXCD-XCN 1/4 NPTF Gauge Port Mounting Holes: .34 diameter through hole, 2 places. 0 L Control 1.69 Max. 3 1 1.00 1.50 G 2.00 2 .59 3.00 .91 0 3.03 3.62 3.31 2.06 1/4 NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-20 GPM Cavity T-2A 3 1 2 1.50 G 0 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF PBFB-LAN-B6B 1/2” NPTF 1/4” NPTF PBFB-LAN-B6C 3/4” NPTF 1/4” NPTF PBFB-LAN-B6D SAE-6 SAE-6 PBFB-LAN-B6I SAE-8 SAE-6 PBFB-LAN-B6J 0 Ports 1 and 2 Mounting Holes: .42 diameter through hole. 2 places 3 1 L Control 1.93 Max. 1.25 .66 G 2.37 2 CXED-XCN 0 1.06 3.62 2.44 1/4 NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 34 for cartridge model PB*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. US Selected Assemblies Catalogue #999-901-192 39 PRESSURE REDUCING Line Mounted Assemblies PRESSURE REDUCING Line Mounted Assemblies THREE PORT PRESSURE REDUCING APPLICATIONS (BODIES WITH REVERSE FREE FLOW CHECK) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-40 GPM 3 Cavity T-17A CXGD-XCN 0 1 2 G Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF PBHB-LAN-H2* 1 1/4” NPTF 1/4” NPTF PBHB-LAN-H2* SAE-12 SAE-6 PBHB-LAN-H2* SAE-16 SAE-6 PBHB-LAN-H2* 2.50 Mounting Holes: .42 diameter through hole, 2 places. 1.44 5.00 3 1 3.50 3.12 .91 L Control 1.87 Max. G 1.50 2 0 3.44 4.75 5.50 0 .38 2.00 1/4 NPTF Gauge Port 5.12 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-80 GPM 3 Cavity T-19A CXID-XCN 0 1 2 G 3.00 Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF PBJB-LAN-KK2* 1 1/4” NPTF 1/4” NPTF PBJB-LAN-KK2* Mounting Holes: .42 diameter through hole, 2 places. 6.00 1 3 4.00 1.13 2.72 Max. G L Control 1.50 2 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .50 1.88 4.41 6.22 7.00 1/4 NPTF Gauge Port 6.50 NOTES: Page 34 for cartridge model PB*B shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 40 US Selected Assemblies Catalogue #999-901-192 Reducing/Relieving Assemblies Cartridge Type Page 3 2 Pilot Operated 42 Direct Acting 42 1 3 2 1 Line Mounted Assemblies (Body Type) 3 2 G 90 Degree, High Capacity Port 3 90 Degree, 1.50 SAE C61/C62 Flange Port, High Capacity Port 3 44 46 90 Degree with Reverse Free Flow Check 90 Degree with Reverse Free Flow Check, High Capacity Port 3 47 48 1 3 2 G 1 US Selected Assemblies Catalogue #999-901-192 41 REDUCING/RELIEVING Reducing/Relieving Valves PILOT OPERATED REDUCING/RELIEVING 3 Capacity 2 1 Typical Cartridge Model Code PPDB – LAN T - 11A 1.38 7/8” 2.50 2.56 T - 2A 1.38 1 1/8” 2.81 2.88 3.06 45/50 40 GPM PPHB – LAN T - 17A 1.81 1 1/4” 3.28 3.31 3.53 150/160 80 GPM PPJB – LAN T - 19A 2.50 1 5/8” 3.94 4.09 4.19 350/375 2.75 PP ✱ B – ✱ ✱ ✱ Base Price Control** Adjustment Range Seal D 10 GPM L Standard Screw A 100 - 3000 psi N Buna-N F 20 GPM C Tamper Resistant W 150 - 4500 psi V Viton H 40 GPM K Handknob B 50 -1500 psi J 80 GPM 2 Inlet Installation Torque (lb. ft.) 30/35 PPFB – LAN Nominal Capacity 3 Tank K 10 GPM Full Adjustment 5 Turns + - c a 20 GPM OPTION ORDERING INFORMATION b Cavity Cartridge Dimensions c b L C N 60 - 800 psi Q 60 - 400 psi Locating Shoulder a 1 Reduced Pressure ** See page 244 for information on Control Options Adjustment Range Options: All are standard set at 200 psi. Maximum pressure differentials for spring ranges: A and B are 3000 psi. N and Q are 2000 psi. W is 5000 psi inlet pressure. Customer may specify pressure setting. DIRECT ACTING REDUCING/RELIEVING 3 Capacity 2 1 Typical Cartridge Model Code Cavity a Cartridge Dimensions c b L C K Installation Torque (lb. ft.) 30/35 10 GPM PRDB – LAN T - 11A 1.38 7/8” 3.09 3.16 3.34 20 GPM PRFB – LAN T - 2A 1.38 1 1/8” 3.47 3.53 3.75 45/50 40 GPM PRHB – LAN T - 17A 1.81 1 1/4” 3.94 4.00 4.19 150/160 80 GPM PRJB – LAN T - 19A 2.50 1 5/8” 4.87 5.03 5.13 350/375 OPTION ORDERING INFORMATION PR ✱ B – ✱ ✱ ✱ Full Adjustment 5 Turns + - Nominal 3 Capacity b c 3 Tank 2 Inlet D F H J Locating Shoulder a 1 Reduced Pressure 10 GPM 20 GPM 40 GPM 80 GPM Base Price Control** L Standard Screw C Tamper Resistant K Handknob Adjustment Range Options: PRDB Only: A, W are standard set at 1000 psi. B, D, E, S are standard set at 200 psi. PRFB, PRHB, PRJB: A, W are standard set at 1000 psi. B is standard set at 500 psi. ** See page 244 D is standard set at 400 psi. for information on E is standard set at 200 psi. Control Options S is standard set at 100 psi. 42 A W B D E S Adjustment Range Seal Available for PRDB only 500 - 3000 psi N Buna-N 750 - 4500 psi V Viton 50 - 1500 psi 20 - 800 psi 20 - 400 psi 20 - 200 psi Available for PRFB, PRHB, PRJB A 750 - 3000 psi W 1000 - 4500 psi B 300 - 1500 psi D 200 - 800 psi E 100 - 400 psi S 50 - 200 psi Maximum Inlet Pressure: 5000 psi Customer may specify pressure setting. US Selected Assemblies Catalogue #999-901-192 REDUCING/RELIEVING TECHNICAL TIPS / PERFORMANCE CURVES Reducing/Relieving Valves, Pilot Operated Regulated Pressure PPDB-L*N Relieving Reducing 1500 P = psi P = psi Reducing 2000 2000 1000 500 1500 1000 500 0 0 -10 -5 0 5 10 Flow = GPM -20 15 PPHB-L*N -10 0 10 20 Flow = GPM 30 PPJB-L*N Relieving Reducing Relieving 2000 Reducing 2000 1500 1000 500 0 1500 1000 500 0 -40 -20 No Load Pressure Drop PP*B-LAN D F H J 200 P = psi PPFB-L*N Relieving P = psi Note: Maximum pressure differentials, inlet to outlet, see adjustment ranges on page 42. Note: Reducing/relieving valves require a body with a high capacity third port. Performance Curves P = psi Applications Pilot operated reducing/relieving cartridges may be used interchangeably with reducing valve, however, they have one additional function; they will maintain a constant pressure at port 1 during reverse flow conditions to port three. Design Concepts and Features ■ Low hysteresis for accurate pressure regulation. ■ Minimal dead-band provides low transition pressure between reducing and relieving modes. ■ Low pilot control flow, 7 to 20 in. 3/min. dependent on frame size. ■ Pressure at port 3 is directly additive to valve setting and should not exceed 3000 psi. 0 20 Flow = GPM 40 -80 60 -40 0 40 80 Flow = GPM 120 150 100 50 0 20 40 60 Flow = GPM 80 Reducing/Relieving Valves, Direct Acting Regulated Pressure PRDB-L*N PRFB-L*N Relieving Relieving Reducing P = psi P = psi 1500 1000 2000 1000 500 0 0 -5 -2.5 0 5 Flow = GPM 10 -40 15 PRHB-L*N -20 Reducing ■ ■ 2000 1000 0 43 15 20 25 Reducing 3000 2000 1000 0 -30 0 10 20 Flow = GPM 30 40 50 -60 -40 Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at zero flow rate. US Selected Assemblies Catalogue #999-901-192 5 10 Relieving 3000 General Application Requirements ■ 0 Flow = GPM PRJB-L*N Relieving -60 ■ Reducing 3000 2000 P = psi Note: Maximum pressure differentials, inlet to outlet, see adjustment ranges on page 42. Performance Curves P = psi Applications Direct acting reducing/relieving cartridges may be used interchangeably with pilot operated units. These valves offer low internal leakage and increased reliability in contaminated systems, this makes them ideal choices in accumulator and brake circuits. They exhibit lower overshoot characteristics than pilot operated valves and should therefore be considered in clamping circuits. Design Concepts and Features ■ Damped differential construction for stable operation. ■ Low internal leakage in both no flow and control flow modes; less than 2 in3/min. ■ Multiple spring ranges for optimum control -20 0 20 40 60 80 Flow = GPM REDUCING/RELIEVING Line Mounted Assemblies THREE PORT PRESSURE REDUCING/RELIEVING APPLICATIONS (90 DEGREE, HIGH CAPACITY PORT 3 BODIES) PILOT OPERATED ASSEMBLIES DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-10 GPM Cavity T-11A 3 1.25 2 .62 G 0 1 Mounting Holes: .34 diameter through hole, 2 places. Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 3/8” NPTF PPDB-LAN-ELB 1/2” NPTF 3/8” NPTF PPDB-LAN-ELC SAE-6 SAE-6 PPDB-LAN-ELI SAE-8 SAE-8 PPDB-LAN-ELJ SAE-10 SAE-8 PPDB-LAN-ELK 0 L Control 2.40 Max. 2 .38 1 1.25 3 G 2.50 .75 0 1.56 2.44 3.00 Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 3/8” NPTF PRDB-LAN-ELB 1/2” NPTF 3/8” NPTF PRDB-LAN-ELC SAE-6 SAE-6 PRDB-LAN-ELI SAE-8 SAE-8 PRDB-LAN-ELJ SAE-10 SAE-8 PRDB-LAN-ELK 1/4 NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-20 GPM Cavity T-2A 3 1.50 2 .75 G 0 1 Ports 1 and 2 Port 3 Assembly Model Code* 1/2” NPTF 1/2” NPTF PPFB-LAN-BLC 3/4” NPTF 1/2” NPTF PPFB-LAN-BLD SAE-6 SAE-6 SAE-8 SAE-10 Mounting Holes: .42 diameter through hole 2 places. Ports 1 and 2 Port 3 Assembly Model Code* 1/2” NPTF 1/2” NPTF PRFB-LAN-BLC 3/4” NPTF 1/2” NPTF PRFB-LAN-BLD PPFB-LAN-BLI SAE-6 SAE-6 PRFB-LAN-BLI SAE-8 PPFB-LAN-BLJ SAE-8 SAE-8 PRFB-LAN-BLJ SAE-10 PPFB-LAN-BLK SAE-10 SAE-10 PRFB-LAN-BLK 0 1 1.62 3 G 3.00 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 2.66 Max. 2 .50 .91 1.72 2.66 3.25 1/4 NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 42 for cartridge models PP*B-*** and PR*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 44 US Selected Assemblies Catalogue #999-901-192 THREE PORT PRESSURE REDUCING/RELIEVING APPLICATIONS (90 DEGREE, HIGH CAPACITY PORT 3 BODIES) PILOT OPERATED ASSEMBLIES DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-40 GPM Cavity T-17A 3 2.25 2 G 1 Ports 1 and 2 Assembly Model Code* Port 3 1” NPTF 3/4” NPTF PPHB-LAN-HEE 1 1/4” NPTF 3/4” NPTF PPHB-LAN-HEF SAE-12 SAE-12 PPHB-LAN-HEL SAE-16 SAE-12 PPHB-LAN-HEM 1.12 0 Mounting Holes: .42 diameter through hole, 2 places. 0 L Control 2.82 Max. 2 .75 1 2.00 G Ports 1 and 2 Port 3 Assembly Model Code* PRHB-LAN-HEE 1” NPTF 3/4” NPTF 1 1/4” NPTF 3/4” NPTF PRHB-LAN-HEF SAE-12 SAE-12 PRHB-LAN-HEL SAE-16 SAE-12 PRHB-LAN-HEM 3 4.00 1.19 2.12 3.44 4.25 1/4 NPTF Gauge Port 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-80 GPM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-19A 3 3.00 2 G 1 Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1” NPTF PPJB-LAN-KEE 1 1/4” NPTF 1” NPTF PPJB-LAN-KEF SAE-16 SAE-16 PPJB-LAN-KEM SAE-20 SAE-16 PPJB-LAN-KEN 1.50 0 Mounting Holes: .42 diameter through hole, 2 places. 0 .50 L Control 2 3.49 Max. 1 2.50 G Ports 1 and 2 Port 3 Assembly Model Code* PRJB-LAN-KEE 1” NPTF 1” NPTF 1 1/4” NPTF 1” NPTF PRJB-LAN-KEF SAE-16 SAE-16 PRJB-LAN-KEM SAE-20 SAE-16 PRJB-LAN-KEN 3 5.00 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.06 2.50 4.31 5.25 1/4 NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 42 for cartridge models PP*B-*** and PR*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 45 REDUCING/RELIEVING Line Mounted Assemblies REDUCING/RELIEVING Line Mounted Assemblies THREE PORT PRESSURE REDUCING/RELIEVING APPLICATIONS (90 DEGREE, 1.50” SAE C61/C62 FLANGE PORT BODIES, HIGH CAPACITY PORT 3) PILOT OPERATED ASSEMBLIES 0-80 GPM 3 DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. Cavity T-19A 4.00 2 G 2.00 1 0 Ports 1, 2, and 3 Assembly Model Code* 1 1/2” SAE C61 PPJB-LAN-KER 1/4 NPTF Gauge Port Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 2 places. 0 .47 Ports 1, 2, and 3 1 1/2” SAE C61 Assembly Model Code* PRJB-LAN-KER L Control 2.81 Max. 2 1.97 1 G *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3 3.94 0 .75 2.19 4.00 0-80 GPM 3 4.50 G 2.25 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.62 Cavity T-19A 2 1 Ports 1, 2, and 3 Assembly Model Code* 1 1/2” SAE C62 PPJB-LAN-KE6 Ports 1, 2, and 3 Assembly Model Code* 1 1/2” SAE C62 PRJB-LAN-KE6 0 1/4 NPTF Gauge Port Mounting Holes: (oppostie side) .375-16 UNC-2B x .62 deep. 2 places. 0 .47 L Control 2 1.97 1 G *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3 3.94 0 .75 2.44 2.56 Max. 4.25 6.13 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 42 for cartridge models PP*B-*** and PR*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 46 US Selected Assemblies Catalogue #999-901-192 THREE PORT PRESSURE REDUCING/RELIEVING APPLICATIONS (BODIES WITH REVERSE FREE FLOW CHECK) PILOT OPERATED ASSEMBLIES 3 DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-10 GPM Cavity T-11A 1.25 2 G 0 CXCD-XCN 1 Mounting Holes: .34 diameter through hole, 2 places. Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 3/8” NPTF PPDB-LAN-E4B 1/2” NPTF 3/8” NPTF PPDB-LAN-E4C SAE-6 SAE-6 PPDB-LAN-E4I SAE-8 SAE-8 PPDB-LAN-E4J SAE-10 SAE-8 PPDB-LAN-E4K 0 Ports 1 and 2 Port 3 Assembly Model Code* 1.00 3/8” NPTF 3/8” NPTF PRDB-LAN-E4B 1.50 1/2” NPTF 3/8” NPTF PRDB-LAN-E4C SAE-6 SAE-6 PRDB-LAN-E4I SAE-8 SAE-8 PRDB-LAN-E4J SAE-10 SAE-8 PRDB-LAN-E4K 1 L Control 2.37 Max. 3 G 2 .59 3.00 0 .91 2.06 3.03 3.62 1/4 NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-20 GPM Cavity T-2A 1.50 2 G 0 CXED-XCN 1 Mounting Holes: .42 diameter through hole, 2 places. Ports 1 and 2 Port 3 Assembly Model Code* 1/2” NPTF 1/2” NPTF PPFB-LAN-B4C 3/4” NPTF 1/2” NPTF PPFB-LAN-B4D SAE-8 SAE-8 PPFB-LAN-B4J SAE-10 SAE-10 PPFB-LAN-B4K 0 3 1 1.25 1.50 G 2 .59 3.62 0 .38 1.06 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.44 L Control 2.58 Max. Ports 1 and 2 Port 3 Assembly Model Code* 1/2” NPTF 1/2” NPTF PRFB-LAN-B4C 3/4” NPTF 1/2” NPTF PRFB-LAN-B4D SAE-8 SAE-8 PRFB-LAN-B4J SAE-10 SAE-10 PRFB-LAN-B4K 3.34 4.00 1/4 NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 42 for cartridge models PP*B-*** and PR*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. US Selected Assemblies Catalogue #999-901-192 47 REDUCING/RELIEVING Line Mounted Assemblies REDUCING/RELIEVING Line Mounted Assemblies THREE PORT PRESSURE REDUCING/RELIEVING APPLICATIONS (BODIES WITH REVERSE FREE FLOW CHECK, HIGH CAPACITY PORT 3) PILOT OPERATED ASSEMBLIES 3 DIRECT ACTING ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-40 GPM Cavity T-17A 2.50 2 G 0 CXGD-XCN 1 Ports 1 and 2 Mounting Holes: .42 diameter through hole, 2 places. Assembly Model Code* Port 3 1” NPTF 3/4” NPTF PPHB-LAN-H4E 1 1/4” NPTF 3/4” NPTF PPHB-LAN-H4F SAE-12 SAE-12 PPHB-LAN-H4L SAE-16 SAE-12 PPHB-LAN-H4M 2.00 0 1 1.50 1.88 .91 2.88 Max. 3 G L Control 2 Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 3/4” NPTF PRHB-LAN-H4E 1 1/4” NPTF 3/4” NPTF PRHB-LAN-H4F SAE-12 SAE-12 PRHB-LAN-H4L SAE-16 SAE-12 PRHB-LAN-H4M 5.00 1.44 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.44 4.75 5.50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1/4 NPTF Gauge Port 0-80 GPM Cavity T-19A 3 3.00 2 G 0 CXID-XCN 1 Ports 1 and 2 Mounting Holes: .42 diameter through hole, 2 places. Port 3 Assembly Model Code* 1” NPTF 3/4” NPTF PPJB-LAN-K4E 1 1/4” NPTF 3/4” NPTF PPJB-LAN-K4F 6.00 3 1 3.94 1.13 L Control G Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 3/4” NPTF PRJB-LAN-K4E 1 1/4” NPTF 3/4” NPTF PRJB-LAN-K4F 3.65 Max. 2 0 0 .50 1.88 4.41 6.22 7.00 1/4 NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 42 for cartridge models PP*B-*** and PR*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 48 US Selected Assemblies Catalogue #999-901-192 Three Port Counterbalance Assemblies Cartridge Type 3 2 Standard, 4000 psi Maximum Setting Standard, 5000 psi Maximum Setting Page 50 50 1 Line Mounted Assemblies (Body Type) 3 2 90 Degree 52 90 Degree 2.00” C61/C62 Flange Port, 2 Cavities 54 Inline 55 90 Degree with Shuttle 56 90 Degree 1.50” C61/C62 SAE Flange Port with Shuttle, 2 Cavities 57 90 Degree Cross-Piloted, 2 Cavities 90 Degree Cross-Piloted, 1.50” SAE C61/C62 Flange Port, 2 Cavities Inline/Inline Cross-Piloted, 1.50” SAE C61 Flange Port, 2 Cavities 58 59 60 90 Degree Cross-Piloted with Shuttle, 2 Cavities Cross-Piloted, 1.50” SAE C61/C62 Flange Port with Shuttle, 2 Cavities 61 62 Inline Cross-Piloted with Shuttle, 2 Cavities 63 Direct Mount .75”/1.00”/1.25” SAE C61 Flange Port, Through Pilot 64 Gasket Mount 66 Gasket Mount, 2 Cavities 67 1 2 3 1 3 2 1 2 S 3 1 2 S 3 1 V1 V2 C1 C2 V1 S V2 C1 C2 V1 S V2 C2 C1 2 3 3 1 V2 V1 C1 C2 V2 V1 C1 C2 US Selected Assemblies Catalogue #999-901-192 49 THREE PORT COUNTERBALANCE Counterbalance Valves STANDARD, 4000 PSI MAXIMUM SETTING 3 2 1 Cartridge Dimensions c b L Capacity Typical Cartridge Model Code Cavity a 15 GPM CBCA – LHN T - 11A 1.38 30 GPM CBEA – LHN T - 2A 1.38 1 1/8” 2.38 2.50 45/50 60 GPM CBGA – LHN T - 17A 1.81 1 1/4” 2.75 3.31 150/160 120 GPM CBIA – LHN T - 19A 2.50 1 5/8” 3.50 4.09 350/375 7/8” 1.97 C 2.19 Installation Torque (lb. ft.) 30/35 OPTION ORDERING INFORMATION CB ✱ ✱ – ✱ ✱ ✱ Turn screw clockwise to reduce setting and release load. Complete Adjustment 3 Turns + - b Nominal Capacity c C 15 GPM L Standard Screw E 30 GPM C Tamper Resistant Seal N Buna-N 30 psi Check Spring H 1000 - 4000 psi I V Viton 400 - 1500 psi Version 120 GPM Locating Shoulder A 3:1 Pilot Ratio 5 psi Check Spring B 1.5:1 Pilot Ratio (with sealed pilot) A 1000 - 4000 psi B 400 - 1500 psi Y 2:1 Pilot Ratio (with bleed through pilot) a 2 Valve Cracking Pressure G 60 GPM I 3 Pilot Control** Adjustment Range Options: A and H are standard set at 3000 psi. I and B are standard set at 1000 psi. Customer may specify setting. ** See page 244 for information on Control Options Load 1 STANDARD, 5000 PSI MAXIMUM SETTING 2 Cavity a 15 GPM CBCG – LJN T - 11A 1.38 7/8” 1.97 2.19 Installation Torque (lb. ft.) 30/35 30 GPM CBEG – LJN T - 2A 1.38 1 1/8” 2.38 2.50 45/50 Capacity 3 1 Cartridge Dimensions c b L Typical Cartridge Model Code C 60 GPM CBGG – LJN T - 17A 1.81 1 1/4” 2.75 3.31 150/160 120 GPM CBIG – LJN T - 19A 2.50 1 5/8” 3.50 4.09 350/375 OPTION ORDERING INFORMATION CB ✱ ✱ – ✱ ✱ ✱ Turn screw clockwise to reduce setting and release load. Complete Adjustment 3 Turns + b c Nominal Capacity C 15 GPM L Standard Screw E 30 GPM C Tamper Resistant G 60 GPM I 3 Pilot Locating Shoulder 2 Valve Load 1 a Control** Cracking Pressure 30 psi Check Spring J 2000 - 5000 psi Seal N Buna-N V Viton K 1000 - 2500 psi Version 120 GPM G 4.5:1 Pilot Ratio 5 psi Check Spring H 10:1 Pilot Ratio C 2000 - 5000 psi L 2.3:1 Pilot Ratio (with sealed pilot) D 1000 - 2500 psi ** See page 244 for information on Control Options 50 Adjustment Range Options: J and C are standard set at 3000 psi. K and D are standard set at 2000 psi. Customer may specify setting. US Selected Assemblies Catalogue #999-901-192 THREE PORT COUNTERBALANCE TECHNICAL TIPS / PERFORMANCE CURVES Counterbalance Valves, 3:1, 1.5:1 and 2:1 Pilot Ratio, External Pilot, Non-vented Performance Curves Free Flow and Pilot Open Pressure Drop CBE*-L*N 400 400 300 300 P = psi P = psi CBC*-L*N 200 100 0 200 100 0 0 5 10 15 0 10 Q = GPM 20 30 80 120 Q = GPM CBG*-L*N CBI*-L*N 400 400 300 300 P = psi P = psi Applications The Sun three port counterbalance cartridges (with pilot to open assist) are modulating devices that allow free flow from port 2 (inlet) to port 1 (load) and then block reverse flow until a pilot pressure inversely proportional to the load pressure is sensed at port 3 (pilot) or load pressure exceeds relief setting. These valves improve the motion control of most control valve systems by ensuring that the actuator always sees a positive load pressure, even under overrunning load situations. Design Concepts and Features ■ Recommended minimum setting should be 1.3 times maximum load induced pressure. ■ 3:1, 1.5:1, 2:1 pilot ratio, load holding to 3000 psi (with 4000 psi setting). ■ Load reactive pilot assist for overcenter load control applications. ■ 5 drops/min. maximum leakage at reseat. ■ Reseat exceeds 85% of set pressure at standard setting. ■ Back pressure at Port 2 may adversely affect operation of valve. For circuits with back pressure Sun recommends vented counterbalance valves CW** (vented valves). 200 100 200 100 0 0 0 20 40 0 60 40 Q = GPM Q = GPM Counterbalance Valves, 4.5:1, 10:1 and 2.3:1 Pilot Ratio, External Pilot, Non-vented Performance Curves Free Flow and Pilot Open Pressure Drop CBE*-L*N 400 400 300 300 P = psi P = psi CBC*-L*N 200 100 0 200 100 0 0 5 10 15 0 Q = GPM ■ ■ ■ 300 P = psi 400 300 200 100 80 120 100 0 0 0 20 40 60 0 Q = GPM 51 30 200 Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at cracking flow 35 cc/min. US Selected Assemblies Catalogue #999-901-192 20 CBI*-L*N 400 General Application Requirements ■ 10 Q = GPM CBG*-L*N P = psi Applications The Sun three port counterbalance cartridges (with pilot to open assist) are modulating devices that allow free flow from port 2 (inlet) to port 1 (load) and then block reverse flow until a pilot pressure inversely proportional to the load pressure is sensed at port 3 (pilot) or load pressure exceeds relief setting. These valves improve the motion control of most control valve systems by ensuring that the actuator always sees a positive load pressure, even under overrunning load situations. Design Concepts and Features ■ Recommended minimum setting should be 1.3 times maximum load induced pressure. ■ 4.5:1 10:1, 2.3:1 pilot ratio, load holding to 3760 psi (with 5000 psi setting). ■ Load reactive pilot assist for overcenter load control applications. ■ 5 drops/min. maximum leakage at reseat. ■ Reseat exceeds 85% of set pressure at standard setting. ■ Back pressure at Port 2 may adversely affect operation of valve. For circuits with back pressure Sun recommends vented counterbalance valves CW** (vented valves). 40 Q = GPM THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT LOAD CONTROL APPLICATIONS (90 DEGREE BODIES) PILOT RATIO 3:1, 1.5:1, 2:1 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. 0-15 GPM Cavity T-11A 3 2 1.25 .62 1 Ports 1 and 2 0 Mounting Holes: .34 diameter through hole 2 places. Assembly Model Code* Port 3 3/8” NPTF 1/4” NPTF CBC*-LHN-ECB 1/2” NPTF 1/4” NPTF CBC*-LHN-ECC SAE-4 SAE-4 CBC*-LHN-ECH SAE-6 SAE-6 CBC*-LHN-ECI SAE-8 SAE-6 CBC*-LHN-ECJ *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .38 1.28 Max. 2 1 1.25 L Control 3 2.50 1.56 0 0-30 GPM Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF CBC*-LJN-ECB 1/2” NPTF 1/4” NPTF CBC*-LJN-ECC SAE-4 SAE-4 CBC*-LJN-ECH SAE-6 SAE-6 CBC*-LJN-ECI SAE-8 SAE-6 CBC*-LJN-ECJ *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.53 3.00 Cavity T-2A 3 2 1.50 .75 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 1/2” NPTF 1/4” NPTF CBE*-LHN-BCC 0 3/4” NPTF 1/4” NPTF CBE*-LHN-BCD .50 SAE-10 SAE-6 CBE*-LHN-BCK SAE-12 SAE-6 CBE*-LHN-BCL Mounting Holes: .42 diameter through hole 2 places. 1.57 Max. 2 1 1.62 3 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.72 Port 3 Assembly Model Code* 1/2” NPTF 1/4” NPTF CBE*-LJN-BCC 3/4” NPTF 1/4” NPTF CBE*-LJN-BCD SAE-10 SAE-6 CBE*-LJN-BCK SAE-12 SAE-6 CBE*-LJN-BCL L Control 3.00 0 Ports 1 and 2 2.66 3.25 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 52 US Selected Assemblies Catalogue #999-901-192 THREE PORT LOAD CONTROL APPLICATIONS (90 DEGREE BODIES) PILOT RATIO 3:1, 1.5:1, 2:1 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. 0-60 GPM Cavity T-17A 3 2 2.25 2.12 1 Ports 1 and 2 0 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF CBG*-LHN-HCE 0 1 1/4” NPTF 1/4” NPTF CBG*-LHN-HCF .75 SAE-12 SAE-6 CBG*-LHN-HCL SAE-16 SAE-6 CBG*-LHN-HCM Mounting Holes: .42 diameter through hole 2 places. 2 L Control 2.61 Max. 1 2.00 Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF CBG*-LJN-HCE 1 1/4” NPTF 1/4” NPTF CBG*-LJN-HCF SAE-12 SAE-6 CBG*-LJN-HCL SAE-16 SAE-6 CBG*-LJN-HCM 3 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4.00 2.12 0 0-120 GPM 3.50 4.25 Cavity T-19A 3 2 3.00 1.50 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF CBI*-LHN-KCE 1 1/4” NPTF 1/4” NPTF CBI*-LHN-KCF SAE-16 SAE-6 CBI*-LHN-KCM SAE-20 SAE-6 CBI*-LHN-KCN 0 .50 Mounting Holes: .42 diameter through hole 2 places. 2.34 Max. 2 1 2.25 Ports 1 and 2 Port 3 Assembly Model Code* CBI*-LJN-KCE 1” NPTF 1/4” NPTF 1 1/4” NPTF 1/4” NPTF CBI*-LJN-KCF SAE-16 SAE-6 CBI*-LJN-KCM SAE-20 SAE-6 CBI*-LJN-KCN 3 L Control *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4.00 0 2.47 4.25 5.00 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 53 THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT LOAD CONTROL APPLICATIONS (90 DEGREE 2.00” C61/C62 FLANGE PORT BODIES, 2 CAVITIES PILOT RATIO 3:1, 1.5:1, 2:1 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. 0-240 GPM Cavity T-11A 2 3 M10 x 1.50-6H x .62 deep. 2 places. 5.94 2 1 L Control 2.34 Max. 3 1 2.97 Ports 1 and 2 Port 3 Assembly Model Code* 2” SAE C61 SAE-6 CBI*-LHN-XZZ 0 0 1.97 0 4.25 6.03 6.75 Ports 1 and 2 Port 3 Assembly Model Code* 2” SAE C61 SAE-4 CBI*-LJN-XZZ 0 .97 2 2.88 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4.97 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.94 0-240 GPM Cavity T-19A 2 3 5.94 1 2.97 Ports 1 and 2 Port 3 2” SAE C62 SAE-6 Assembly Model Code* CBI*-LHN-Z8Z 2 3 0 Mounting Holes: .500-13 UNC-2B x .87 deep. 2 places. L Control 0 2.34 Max. 1.06 2.97 Ports 1 and 2 Port 3 Assembly Model Code* 2” SAE C62 SAE-6 CBI*-LJN-Z8Z 1 4.88 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.94 0 2.26 4.97 7.50 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 54 US Selected Assemblies Catalogue #999-901-192 THREE PORT LOAD CONTROL APPLICATIONS (INLINE BODIES) PILOT RATIO 3:1, 1.5:1, 2:1 0-15 GPM Cavity T-11A 3 2 Mounting Holes: .34 diameter through 2 places. Counterbore for 5/16 bolt. 1 Ports 1 and 2 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. Assembly Model Code* Port 3 L Control 1.28 Max. 2.64 3/8” NPTF 1/4” NPTF CBC*-LHN-EJB SAE-6 SAE-6 CBC*-LHN-EJI 2.05 SAE-8 SAE-6 CBC*-LHN-EJJ 1.28 3 1.25 .66 2 0 1.78 1.16 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF CBC*-LJN-EJB SAE-6 SAE-6 CBC*-LJN-EJI SAE-8 SAE-6 CBC*-LJN-EJJ 1 0 0 0 .29 .31 0 Ports 1 and 2 1.26 3.38 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-30 GPM Cavity T-2A 3 2 Mounting Holes: .34 diameter through hole Counterbore for hex head bolt. 2 places. 1 Ports 1 and 2 Port 3 Assembly Model Code* 1/2” NPTF 1/4” NPTF CBE*-LHN-BVC 3.22 3/4” NPTF 1/4” NPTF CBE*-LHN-BVD 2.56 L Control 1.66 Max. SAE-6 SAE-6 CBE*-LHN-BVI 1.68 SAE-8 SAE-6 CBE*-LHN-BVJ .88 1.66 2 0 2.12 1.34 3 1 0 .31 0 Ports 1 and 2 Port 3 Assembly Model Code* 1/2” NPTF 1/4” NPTF CBE*-LJN-BVC 3/4” NPTF 1/4” NPTF CBE*-LJN-BVD SAE-6 SAE-6 CBE*-LJN-BVI SAE-8 SAE-6 CBE*-LJN-BVJ 0 0 1.44 3.88 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-60 GPM Cavity T-17A 3 2 Mounting Holes: .42 diameter through hole. 1.00 diameter counterbore. 2 places. 1 Ports 1 and 2 Port 3 Assembly Model Code* 3/4” NPTF 1/4” NPTF CBG*-LHN-HDD 1” NPTF 1/4” NPTF CBG*-LHN-HDE SAE-12 SAE-6 CBG*-LHN-HDL SAE-16 SAE-6 CBG*-LHN-HDM L Control 1.84 Max. 3.88 3.16 3 2.28 2.28 .94 0 3.00 1.69 1 2 0 .38 0 Port 3 Assembly Model Code* 3/4” NPTF 1/4” NPTF CBG*-LJN-HDD 1” NPTF 1/4” NPTF CBG*-LJN-HDE SAE-12 SAE-6 CBG*-LJN-HDL SAE-16 SAE-6 CBG*-LJN-HDM 0 0 .38 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports 1 and 2 1.96 4.62 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 55 THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT LOAD CONTROL APPLICATIONS (90 DEGREE BODIES WITH SHUTTLE) PILOT RATIO 3:1, 1.5:1, 2:1 0-15 GPM 2 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. Cavity T-11A S 3 0 .62 1 Ports 1 and 2 Ports Shuttle and 3 1.25 Assembly Model Code* 3/8” NPTF 1/4” NPTF CBC*-LHN-EGB 1/2” NPTF 1/4” NPTF CBC*-LHN-EGC SAE-6 SAE-6 CBC*-LHN-EGI SAE-8 SAE-6 CBC*-LHN-EGJ SAE-10 SAE-6 CBC*-LHN-EGK Mounting Holes: .34 diameter through hole, 2 places. 3.00 2.62 1.28 Max. 2 1.75 1 L Control Ports 1 and 2 Ports Shuttle and 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF CBC*-LJN-EGB 1/2” NPTF 1/4” NPTF CBC*-LJN-EGC SAE-6 SAE-6 CBC*-LJN-EGI SAE-8 SAE-6 CBC*-LJN-EGJ SAE-10 SAE-6 CBC*-LJN-EGK 3 S 0 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 1.38 0-30 GPM 2 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.53 3.00 Cavity T-2A S 3 0 .62 1 Ports 1 and 2 Ports Shuttle and 3 1/2” NPTF 3/4” NPTF 1.25 Assembly Model Code* 3.25 1/4” NPTF CBE*-LHN-BGC 2.75 1/4” NPTF CBE*-LHN-BGD SAE-6 SAE-6 CBE*-LHN-BGI SAE-8 SAE-6 CBE*-LHN-BGJ Mounting Holes: .42 diameter through hole, 2 places. 1.60 Max. 2 1 1.75 Ports 1 and 2 Ports Shuttle and 3 Assembly Model Code* 1/2” NPTF 1/4” NPTF CBE*-LJN-BGC 3/4” NPTF 1/4” NPTF CBE*-LJN-BGD SAE-6 SAE-6 CBE*-LJN-BGI SAE-8 SAE-6 CBE*-LJN-BGJ L Control 3 S *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 0 1.56 0-60 GPM 2 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.69 3.25 Cavity T-17A S 3 2.25 1.12 1 0 Ports 1 and 2 Ports Shuttle and 3 Assembly Model Code* 1” NPTF 1/4” NPTF CBG*-LHN-HDE 1 1/4” NPTF 1/4” NPTF CBG*-LHN-HDF SAE-12 SAE-6 CBG*-LHN-HDL SAE-16 SAE-6 CBG*-LHN-HDM 0 Mounting Holes: .42 diameter through hole, 2 places. 1.63 Max. 2 .75 2.00 1 Ports 1 and 2 Ports Shuttle and 3 Assembly Model Code* 1” NPTF 1/4” NPTF CBG*-LJN-HDE 1 1/4” NPTF 1/4” NPTF CBG*-LJN-HDF SAE-12 SAE-6 CBG*-LJN-HDL SAE-16 SAE-6 CBG*-LJN-HDM L Control S *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3 4.00 0 .75 2.25 3.44 4.25 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 56 US Selected Assemblies Catalogue #999-901-192 THREE PORT LOAD CONTROL APPLICATIONS (90 DEGREE 1.50” SAE FLANGE PORT C61/C62 BODIES WITH SHUTTLE) PILOT RATIO 3:1, 1.5:1, 2:1 0-240 GPM 2 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. Cavity T-19A S 3 Port S in end of cartridge Mounting Holes: CSAA-EXN .375-16 UNC-2B .72 x .63 deep. 2 places. 3.94 3.47 1 Ports 1 and 2 Ports Shuttle and 3 SAE-4 1 1/2” SAE C61 Assembly Model Code* 1.62 CBI*-LHN-KGR .47 0 2.31 Max. 3 1 2 0 L Control 2.19 0 Ports 1 and 2 Ports Shuttle and 3 1 1/2” SAE C61 SAE-4 CBI*-LJN-KGR 3.88 4.75 2.00 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4.00 0-240 GPM 2 S 3 Cavity T-19A Port S in end of cartridge Mounting Holes: CSAA-EXN .375-16 UNC-2B x .63 deep. 2 places. .72 3.94 3.47 3 1 1.88 Ports 1 and 2 Ports Shuttle and 3 Assembly Model Code* 1 1/2” SAE C62 SAE-6 CBI*-LHN-KG6 1 3 2 .47 0 1 2.33 Max. 2 L Control 0 2.44 Ports 1 and 2 Ports Shuttle and 3 Assembly Model Code* 1 1/2” SAE C62 SAE-6 CBI*-LJN-KG6 4.12 5.00 0 2.25 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4.50 NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. US Selected Assemblies Catalogue #999-901-192 57 THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT LOAD CONTROL APPLICATIONS (90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES) PILOT RATIO 3:1, 1.5:1, 2:1 V1 0-15 GPM V2 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. Cavity T-11A 1.25 .62 C1 0 C2 Mounting Holes: .34 diameter through hole, 2 places. Ports C1, C2, V1 & V2 Assembly Model Code* 3/8” NPTF CBC*-LHN-YEB 1/2” NPTF CBC*-LHN-YEC SAE-6 CBC*-LHN-YEI SAE-8 CBC*-LHN-YEJ SAE-10 CBC*-LHN-YEK 0 .38 C1 1.25 V1 Assembly Model Code* 3/8” NPTF CBC*-LJN-YEB 1/2” NPTF CBC*-LJN-YEC C2 2.75 V2 0 .50 3.00 1.56 SAE-6 CBC*-LJN-YEI SAE-8 CBC*-LJN-YEJ SAE-10 CBC*-LJN-YEK *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4.00 0-30 GPM V2 Ports C1, C2, V1 & V2 L Control 3.62 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.63 Max. V1 Cavity T-2A 1.50 .75 C1 0 C2 Mounting Holes: .42 diameter through hole, 2 places. Ports C1, C2, V1 & V2 Assembly Model Code* 3/8” NPTF CBE*-LHN-YAB 1/2” NPTF CBE*-LHN-YAC 3/4” NPTF CBE*-LHN-YAD SAE-10 CBE*-LHN-YAK SAE-12 CBE*-LHN-YAL 0 1.50 3.00 C1 Ports C1, C2, V1 & V2 Assembly Model Code* 3/8” NPTF CBE*-LJN-YAB 1/2” NPTF CBE*-LJN-YAC 3/4” NPTF CBE*-LJN-YAD SAE-10 CBE*-LJN-YAK SAE-12 CBE*-LJN-YAL C2 V2 4.00 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.60 Max. V1 .50 L Control 4.50 0 .50 3.25 1.75 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 58 US Selected Assemblies Catalogue #999-901-192 THREE PORT LOAD CONTROL APPLICATIONS (90 DEGREE CROSS-PILOTED, 1.50” SAE C61/C62 FLANGE PORT BODIES, 2 CAVITIES) PILOT RATIO 3:1, 1.5:1, 2:1 V1 0-60 GPM V2 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. Cavity T-17A 2.25 1.12 C1 0 C2 Ports C1, C2, V1 & V2 Assembly Model Code* 1” NPTF CBG*-LHN-YJE 1 1/4” NPTF CBG*-LHN-YJF SAE-12 CBG*-LHN-YJL SAE-16 CBG*-LHN-YJM Mounting Holes: .42 diameter through hole, 2 places. L Control 0 C1 2.00 5.75 V1 V2 6.50 .75 0 2.09 0-120 GPM V2 Ports C1, C2, V1 & V2 Assembly Model Code* 1” NPTF CBG*-LJN-YJE 1 1/4” NPTF CBG*-LJN-YJF SAE-12 CBG*-LJN-YJL SAE-16 CBG*-LJN-YJM C2 4.50 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.84 Max. V1 .75 4.00 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-19A 4.50 2.25 C1 C2 0 Ports C1, C2, V1 & V2 Assembly Model Code* 1 1/2” SAE C62 CBI*-LHN-YM6 Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 4 places. 0 .52 V1 2.53 2.34 Max. Ports C1, C2, V1 & V2 Assembly Model Code* 1 1/2” SAE C61 CBI*-LJN-YM6 C1 L Control 6.50 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V1 C2 V2 8.52 9.03 0 2.41 0-120 GPM V2 4.94 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-19A 4.00 2.00 C1 C2 Ports C1, C2, V1 & V2 Assembly Model Code* 1 1/2” SAE C61 CBI*-LHN-YMR *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 Mounting Holes: (opposite side) M10 x 1.50-6H x .62 deep. 2 places. 2.32 Max. 0 V1 2.12 C1 5.62 C2 V2 7.75 0 1.88 4.44 Ports C1, C2, V1 & V2 Assembly Model Code* 1 1/2” SAE C61 CBI*-LJN-YMR *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 59 THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT LOAD CONTROL APPLICATIONS (INLINE/INLINE CROSS-PILOTED, 1.50” SAE C61 FLANGE PORT BODIES, 2 CAVITIES) PILOT RATIO 3:1, 1.5:1, 2:1 V1 C1 0-15 GPM V2 Cavity T-11A Mounting Holes: .34 diameter through hole .88 diameter socket clearance. 2 places. C2 L Control 1.28 Max. Ports C1, C2, V1 & V2 Assembly Model Code* 3/8” NPTF CBC*-LHN-XVG 2.05 SAE-6 CBC*-LHN-XVH 1.28 SAE-8 CBC*-LHN-XVI *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V1 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. 2.64 V1 V2 2.94 2.31 1.47 .62 3/8” NPTF CBC*-LJN-XVG SAE-6 CBC*-LJN-XVH SAE-8 CBC*-LJN-XVI C2 V2 0 0 0 .29 0 3.10 3.38 0-30 GPM V2 Assembly Model Code* 1.28 .66 0 Ports C1, C2, V1 & V2 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-2A Mounting Holes: .34 diameter through hole .88 diameter socket clearance. 2 places. C1 L Control 1.66 Max. C2 3.22 Ports C1, C2, V1 & V2 2.56 Assembly Model Code* SAE-10 CBE*-LHN-XAL SAE-12 CBE*-LHN-XAK V1 V2 V1 3.62 2.84 1.81 1.66 .78 0 0.28 3.59 3.88 3.88 C2 Assembly Model Code* SAE-16 CBG*-LHN-XJM SAE-20 CBG*-LHN-XJL *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V1 V1 V2 3.63 2.37 1.13 C2 V2 .94 0 0 4.63 4.25 0-120 GPM V2 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.28 0 4.75 CBE*-LJN-XAL CBE*-LJN-XAK Mounting Holes: .42 diameter through hole. 2.31 Ports C1, C2, V1 & V2 SAE-10 SAE-12 Cavity T-17A L Control 2.75 Max. C1 Assembly Model Code* 0 0 0-60 GPM V2 C2 V2 .88 0 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports C1, C2, V1 & V2 1.66 .38 0 Cavity T-19A Mounting Holes: M10 x1.50-6 H x 22.4 deep. 4 places. L Control 2.34 Max. C1 C2 6.29 5.00 Ports C1, C2, V1 & V2 Assembly Model Code* 1 1/2” SAE C61 CBIA-LHN-XZP *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V2 V1 C2 2.00 0 0 1.28 1.88 6.28 5.69 0 .50 4.50 5.00 NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 60 US Selected Assemblies Catalogue #999-901-192 THREE PORT LOAD CONTROL APPLICATIONS (90 DEGREE CROSS-PILOTED BODIES WITH SHUTTLE, 2 CAVITIES) PILOT RATIO 3:1, 1.5:1, 2:1 0-15 GPM V1 S PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. Cavity T-11A V2 1.25 .62 C1 C2 0 Ports C1, C2, V1 & V2 S Port Assembly Model Code* 3/8” NPTF 1/4” NPTF CBC*-LHN-YGB 1/2” NPTF 1/4” NPTF CBC*-LHN-YGC Mounting Holes: .34 diameter through hole, 2 places. L Control 0 1.28 Max. .38 V1 C1 1.25 SAE-6 SAE-4 CBC*-LHN-YGI 2.00 SAE-8 SAE-4 CBC*-LHN-YGJ 2.75 SAE-10 SAE-4 CBC*-LHN-YGK S C2 V1 S 4.00 0 .50 1.56 0-30 GPM V2 S Port Assembly Model Code* 3/8” NPTF 1/4” NPTF CBC*-LJN-YGB 1/2” NPTF 1/4” NPTF CBC*-LJN-YGC SAE-6 SAE-4 CBC*-LJN-YGI SAE-8 SAE-4 CBC*-LJN-YGJ SAE-10 SAE-4 CBC*-LJN-YGK V2 3.62 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports C1, C2, V1 & V2 3.00 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-2A 1.50 .75 C1 0 C2 Ports C1, C2, V1 & V2 S Port Assembly Model Code* 1/2” NPTF 1/4” NPTF CBE*-LHN-YHC 3/4” NPTF 1/4” NPTF CBE*-LHN-YHD SAE-10 SAE-4 CBE*-LHN-YHK SAE-12 SAE-4 CBE*-LHN-YHL Mounting Holes: .42 diameter through hole, 2 places. L Control 0 C1 1.50 S 2.44 C2 3.38 V1 S 4.88 0 .50 1.75 0-60 GPM V2 Ports C1, C2, V1 & V2 S Port Assembly Model Code* 1/2” NPTF 1/4” NPTF CBE*-LJN-YHC 3/4” NPTF 1/4” NPTF CBE*-LJN-YHD SAE-10 SAE-4 CBE*-LJN-YHK SAE-12 SAE-4 CBE*-LJN-YHL V2 4.38 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.60 Max. V1 .50 3.25 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-17A 2.25 1.12 C1 Ports C1, C2, V1 & V2 S Port 0 C2 Assembly Model Code* .72 CSAA-EXN Mounting Holes: .42 diameter through hole, 2 places. L Control 1” NPTF SAE-4 CBG*-LHN-YKE 0 .75 1 1/4” NPTF SAE-4 CBG*-LHN-YKF 2.00 SAE-12 SAE-4 CBG*-LHN-YKL SAE-16 SAE-4 CBG*LHN-YKM V1 C1 S 3.25 4.50 Ports C1, C2, V1 & V2 S Port Assembly Model Code* 1” NPTF SAE-4 CBG*-LJN-YKE 1 1/4” NPTF SAE-4 CBG*-LJN-YKF SAE-12 SAE-4 CBG*-LJN-YKL SAE-16 SAE-4 CBG*-LJN-YKM C2 5.75 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.84 Max. V2 6.50 0 .75 2.09 4.00 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. US Selected Assemblies Catalogue #999-901-192 61 THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT LOAD CONTROL APPLICATIONS (CROSS-PILOTED 1.50” SAE C61/C62 FLANGE PORT BODIES WITH SHUTTLE, 2 CAVITIES) PILOT RATIO 3:1, 1.5:1, 2:1 0-120 GPM V1 S PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. Cavity T-19A V2 4.00 2.00 C1 Ports C1, C2, V1, V2 S Port 1 1/2” SAE C61 SAE-4 C2 0 Assembly Model Code* .72 CSAA-EXN Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 2 places. L Control 0 2.31 Max. V1 CBI*-LHN-YNR Ports C1, C2, V1, V2 S Port Assembly Model Code* 1 1/2” SAE C61 SAE-4 CBI*-LJN-YNR C1 2.12 S C2 5.62 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V2 7.75 0 1.88 0-120 GPM V1 S 4.44 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-19A V2 4.50 2.25 C1 Ports C1, C2, V1, V2 S Port 1 1/2” SAE C62 SAE-4 C2 0 Assembly Model Code* .66 CSAA-EXN Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 4 places. L Control 0 2.34 Max. CBI*-LHN-YN6 V1 Ports C1, C2, V1, V2 S Port Assembly Model Code* 1 1/2” SAE C62 SAE-4 CBI*-LJN-YN6 C1 2.53 S 6.50 C2 V2 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 9.03 0 2.41 4.94 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 62 US Selected Assemblies Catalogue #999-901-192 THREE PORT LOAD CONTROL APPLICATIONS (INLINE CROSS-PILOTED BODIES WITH SHUTTLE, 2 CAVITIES) PILOT RATIO 3:1, 1.5:1, 2:1 V1 S C1 0-15 GPM V2 Cavity T-11A Mounting Holes: .34 diameter through hole .88 diameter socket clearance. 2 places. C2 Ports C1, C2, V1, V2 Shuttle Port Assembly Model Code* 3/8” NPTF SAE-6 SAE-8 SAE-4 SAE-4 SAE-4 CBC*-LHN-XGB CBC*-LHN-XGI CBC*-LHN-XGJ Shuttle Port in End of Hex L Control 1.28 Max. CSAA-EXN 2.64 2.05 1.25 V1 V2 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. C1 C2 Shuttle Port Assembly Model Code* 1/2” NPTF 3/4” NPTF SAE-4 SAE-4 CBE*-LHN-XHC CBE*-LHN-XHD Ports C1, C2, V1, V2 3/4” NPTF 1” NPTF 3.38 Assembly Model Code* 3/8” NPTF SAE-6 SAE-8 SAE-4 SAE-4 SAE-4 CBC*-LJN-XGB CBC*-LJN-XGI CBC*-LJN-XGJ *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-2A L Control 1.31 Max. 2.56 1.65 V2 3.62 2.84 V2 .88 0 .78 0 Ports C1, C2, V1, V2 Shuttle Port Assembly Model Code* 1/2” NPTF 3/4” NPTF SAE-4 SAE-4 CBE*-LJN-XHC CBE*-LJN-XHD C2 0 0 0-60 GPM V2 CSAA-EXN 3.22 V1 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. C1 Shuttle Port Mounting Holes: .34 diameter through hole. .88 diameter socket clearance. Shuttle Ports 2 places. in End of Hex Ports C1, C2, V1, V2 V1 S Ports C1, C2, V1, V2 0 0 .29 0-30 GPM V2 C2 V2 0 .59 0 3.06 2.47 1.56 1.25 .66 0 V1 S PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. 3.38 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-17A Shuttle Port in end of Hex Mounting Holes: .41 diameter L Control through hole. 1.81 Max. CSAA-BXN 3.88 C2 Shuttle Port Assembly Model Code* SAE-4 SAE-4 CBE*-LHN-XKD CBE*-LHN-XKE 2.31 V1 V2 C2 V2 .94 0 0 4.75 3.62 2.38 1.12 4.62 0 Ports C1, C2, V1, V2 Shuttle Port Assembly Model Code* 3/4” NPTF 1” NPTF SAE-4 SAE-4 CBE*-LHN-XKD CBE*-LHN-XKE Ports C1, C2, V1, V2 Shuttle Port Assembly Model Code* 1 1/2” C61 SAE-4 CBE*-LJN-XZQ 0 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V1 S 0-120 GPM V2 Cavity T-19A Shuttle Port in end of Hex L Control 2.35 Max. CSAA-BXN 6.19 C1 C2 .47 4.00 Ports C1, C2, V1, V2 Shuttle Port Assembly Model Code* 1 1/2” C61 SAE-4 CBE*-LHN-XZQ V2 2.00 V1 C1 0 7.56 0 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.88 0 5.00 5.69 Mounting Holes: M10 x1.50-6 H x .88 deep. 4 places. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. US Selected Assemblies Catalogue #999-901-192 63 THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT LOAD CONTROL APPLICATIONS (DIRECT MOUNT .75”/1.00”/1.25” SAE C61 FLANGE PORT BODIES, THROUGH PILOT) The direct mounted SAE flange port bodies provide the opportunity to mount load control valves directly onto the ports of an actuator. PILOT RATIO 3:1, 1.5:1, 2:1 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. 0-30 GPM 2 Cavity T-2A 3 3 2.50 Ports 1 and 2 Port 3 3/4” SAE C61 SAE-6 2 1.25 1 Assembly Model Code* 0 CBE*-LHN-ZNV 0 L Control 1.50 Max. 2 Ports 1 and 2 Port 3 Assembly Model Code* 3/4” SAE C61 SAE-6 CBE*-LJN-ZNV 3 1.25 1 2.25 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 1.03 1.91 0-30 GPM 2 2.84 3.50 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. -214 O-ring Cavity T-17A 3 3 3.00 1 Ports 1 and 2 Assembly Model Code* Port 3 1” SAE C61 CBG*-LHN-ZNW SAE-6 2 1.50 Ports 1 and 2 0 0 2 1.13 Port 3 Assembly Model Code* 1/2” NPTF CBG*-LJN-ZNW SAE-8 CBG*-LJN-ZNW 3 1 2.94 0 1.16 2.19 3.50 4.13 -219 O-ring *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-60 GPM 2 L Control 2.34 Max. *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-19A 3 3 3.50 1 Ports 1 and 2 1 1/4 SAE C61 Port 3 SAE-6 2 1.75 Assembly Model Code* CBG*-LHN-ZNX 0 0 L Control 2.74 Max. 2 Ports 1 and 2 1 1/4 SAE C6 Port 3 Assembly Model Code* CBG*-LJN-ZNX 3 1.72 1 3.44 0 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.44 2.62 -222 O-ring 4.81 5.50 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 64 US Selected Assemblies Catalogue #999-901-192 THREE PORT LOAD CONTROL APPLICATIONS (DIRECT MOUNT .75”/1.00”/1.25” SAE C62 FLANGE BODIES, THROUGH PILOT) The direct mounted SAE flange port bodies provide the opportunity to mount load control valves directly onto the ports of an actuator. PILOT RATIO 3:1, 1.5:1, 2:1 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. 0-30 GPM 2 Cavity T-2A 3 3 3.00 Ports 1 and 2 Assembly Model Code* Port 3 3/4” SAE C62 0 CBE*-LHN-ZDS SAE-6 2 1.50 1 L Control 1.66 Max. 0 Ports 1 and 2 Port 3 Assembly Model Code* 3/4” SAE C62 SAE-6 CBE*-LJN-ZDS 2 1.22 3 1 2.44 1.19 0 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.12 0-60 GPM 2 3.03 3.53 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. -214 O-ring Cavity T-17A 3 3 3.50 Ports 1 and 2 Assembly Model Code* Port 3 1” SAE C62 0 0 CBG*-LHN-ZDR SAE-6 2 1.75 1 L Control 1.81 Max. Ports 1 and 2 Port 3 Assembly Model Code* 1” SAE C62 SAE-6 CBG*-LJN-ZDR 2 3 1.72 1 3.44 0 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.38 2.47 0-120 GPM 2 3.69 4.31 -219 O-ring *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-19A 3 3 4.00 Ports 1 and 2 1 1/4” SAE C62 Port 3 SAE-6 2 2.00 1 Assembly Model Code* CBI*-LHN-ZFD 0 0 L Control 2.31 Max. 2 1.97 Ports 1 and 2 Port 3 Assembly Model Code* 1 1/4” SAE C62 SAE-6 CBI*-LJN-ZFD 3 1 3.94 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 1.53 2.78 -222 O-ring 4.88 5.62 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. US Selected Assemblies Catalogue #999-901-192 65 THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT LOAD CONTROL APPLICATIONS (GASKET MOUNT BODIES) These compact gasket-mounted bodies provide the opportunity to mount load control valves directly onto the ports of an actuator. PILOT RATIO 3:1, 1.5:1, 2:1 V2 0-15 GPM V1 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. Cavity T-11A Mounting Holes: .34 diameter through hole, 2 places. C1 L Control 1.28 Max. 2.50 V1 2.00 C2 1.63 Ports C2, V1 & V2 Assembly Model Code* 1.03 .81 3/8” NPTF CBC*-LHN-ZTN SAE-6 CBC*-LHN-ZTC .50 .31 0 V2 C1 C2 .50 Assembly Model Code* 3/8” NPTF CBC*-LJN-ZTN SAE-6 CBC*-LJN-ZTC 3.75 1.00 0 Ports C2, V1 & V2 0 .59 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V2 1.19 0-30 GPM V1 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. -113 O-ring Cavity T-2A Mounting Holes: .42 diameter through hole, 2 places. C1 V1 2.38 C2 L Control 1.63 Max. 3.00 1.94 Ports C2, V1 & V2 Assembly Model Code* 1/2” NPTF CBE*-LHN-ZTF SAE-8 CBE*-LHN-ZTG 1.22 .94 .63 .34 0 V2 0 Ports C2, V1 & V2 C1 C2 .63 1.22 Assembly Model Code* 1/2” NPTF CBE*-LJN-ZTF SAE-8 CBE*-LJN-ZTG 4.25 1.44 .72 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V2 -117 O-ring 0-60 GPM V1 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 Cavity T-17A Mounting Holes: .53 diameter through hole, counterbore .78 diameter L Control x .44 deep. 2 places. C1 4.00 C2 Assembly Model Code* 1.56 3/4” NPTF CBG*-LHN-ZTJ 1.06 SAE-12 CBG*-LHN-ZTK Ports C2, V1 & V2 1.69 Max. 3.25 2.69 V1 Ports C2, V1 & V2 C1 C2 V2 .44 0 0 1.44 Assembly Model Code* 3/4” NPTF CBG*-LJN-ZTJ SAE-12 CBG*-LJN-ZTK 5.47 0 1.09 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.19 -121 O-ring Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 66 US Selected Assemblies Catalogue #999-901-192 THREE PORT LOAD CONTROL APPLICATIONS (GASKET MOUNT BODIES, 2 CAVITIES) The gasket-mounted bodies provide the opportunity to mount load control valves directly onto the ports of an actuator. PILOT RATIO 3:1, 1.5:1 V2 PILOT RATIO 2.3:1, 4.5:1, 10:1 Go to www.sunhydraulics.com for more product information and pricing. 0-15 GPM V1 Cavity T-11A 0 C1 C2 1.28 Max. 1.69 2.19 Ports C2, V1 & V2 Assembly Model Code* 3/8” NPTF CBC*-LHN-YVM SAE-6 CBC*-LHN-YVY -113 O-ring Mounting Holes: (opposite side) .34 diameter through hole, counterbore .50 diameter x .25 deep. 2 places. C1 C2 L Control 1.28 Max. 0 0 1.00 0-30 GPM V1 3/8” NPTF CBC*-LJN-YVM SAE-6 CBC*-LJN-YVY V1 V2 V2 Assembly Model Code* 2.50 2.00 1.62 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier / S to order Ductile Iron for pressure rating over 3000 psi. Ports C2, V1 & V2 3.75 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier / S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-2A 0 .81 C1 C2 1.63 Max. 2.75 Ports C2, V1 & V2 Assembly Model Code* 1/2” NPTF CBE*-LHN-YVW SAE-8 CBE*-LHN-YVV -117 O-ring Mounting Holes: .41 diameter through hole, counterbore .59 diameter L Control 2 places. 3.00 C1 CBE*-LJN-YVW SAE-8 CBE*-LJN-YVV C2 .34 0 0 1.22 0-60 GPM V1 1/2” NPTF V1 V2 V2 Assembly Model Code* 1.63 Max. 2.38 1.94 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier / S to order Ductile Iron for pressure rating over 3000 psi. Ports C2, V1 & V2 4.25 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier / S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-17A 0 C1 C2 1.69 Max. 2.50 3.94 Ports C2, V1 & V2 Assembly Model Code* 3/4” NPTF CBG*-LHN-YVT SAE-12 CBG*-LHN-YVS -121 O-ring Mounting Holes: (opposite side) .53 diameter through hole, counterbore .78 diameter x .44 deep. 2 places. CBG*-LJN-YVT SAE-12 CBG*-LJN-YVS V1 C1 .44 0 C2 L Control 1.69 Max V2 1.44 5.47 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier / S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. US Selected Assemblies Catalogue #999-901-192 Assembly Model Code* 3/4” NPTF 4.00 3.25 2.69 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 50. Add modifier / S to order Ductile Iron for pressure rating over 3000 psi. Ports C2, V1 & V2 67 THREE PORT COUNTERBALANCE Line Mounted Assemblies THREE PORT COUNTERBALANCE Line Mounted Assemblies NOTES 68 US Selected Assemblies Catalogue #999-901-192 Four Port Counterbalance Assemblies Cartridge Type Page 4 3 2 Vented, 4000 psi Maximum Setting Vented, 6000 psi Maximum Setting 70 70 1 Line Mounted Assemblies (Body Type) 4 3 2 90 Degree 72 90 Degree with Gauge Port 73 2.00” SAE C62 Flange Port, 2 Cavities 74 90 Degree Cross-Piloted, 2 Cavities, Common Port 4 75 1 3 2 4 G 1 4 3 2 1 2A 2B 4 1A 1B US Selected Assemblies Catalogue #999-901-192 69 FOUR PORT COUNTERBALANCE Counterbalance Valves VENTED, 4000 PSI MAXIMUM SETTING 4 Capacity Cavity a 15 GPM CWCA– LHN T - 21A 1.38 30 GPM CWEA– LHN T - 22A 1.38 1 1/8” 3.29 3.54 45/50 60 GPM CWGA– LHN T - 23A 1.81 1 1/4” 3.75 3.97 150/160 120 GPM CWIA – LHN T - 24A 2.50 1 7/8” 4.58 4.78 350/375 3 2 1 Cartridge Dimensions c b L Typical Cartridge Model Code 7/8” 2.91 C 3.16 Installation Torque (lb. ft.) 30/35 OPTION ORDERING INFORMATION CW ✱ ✱ – ✱ ✱ ✱ Turn screw clockwise to reduce setting and release load. Complete Adjustment 5 Turns + b Nominal Capacity C 15 GPM L Standard Screw E 30 GPM C Tamper Resistant I 4 Vent Seal N Buna-N A and K Pilot Ratios H 1000 - 4000 psi I V Viton 400 - 1500 psi Version 120 GPM A 3:1 Pilot Ratio K 1:1 Pilot Ratio Locating Shoulder 2 Valve Cracking Pressure G 60 GPM c 3 Pilot Control** a Adjustment Range Options: H is standard set at 3000 psi. I is standard set at 1000 psi. Customer may specify setting. ** See page 244 for information on Control Options Load 1 VENTED, 6000 PSI MAXIMUM SETTING 4 Capacity 3 2 1 Typical Cartridge Model Code Cavity a Cartridge Dimensions c b L C Installation Torque (lb. ft.) 30/35 15 GPM CWCG– LFN T - 21A 1.38 7/8” 2.91 30 GPM CWEG– LFN T - 22A 1.38 1 1/8” 3.29 3.54 45/50 60 GPM CWGG– LFN T - 23A 1.81 1 1/4” 3.75 3.97 150/160 120 GPM CWIG – LFN T - 24A 2.50 1 7/8” 4.58 4.78 350/375 3.16 OPTION ORDERING INFORMATION CW ✱ ✱ – ✱ ✱ ✱ Turn screw clockwise to reduce setting and release load. Complete Adjustment 5 Turns + b Nominal Capacity C 15 GPM L Standard Screw E 30 GPM C Tamper Resistant G 60 GPM c I 4 Vent 3 Pilot Locating Shoulder 2 Valve Load 1 Control** Cracking Pressure G and L Pilot Ratios F 1000 - 3500 psi Seal N Buna-N V Viton G 2000 - 6000 psi Version 120 GPM G 5:1 Pilot Ratio L 2:1 Pilot Ratio a ** See page 244 for information on Control Options 70 Adjustment Range Options: F is standard set at 2000 psi. G is standard set at 4000 psi. Customer may specify setting. US Selected Assemblies Catalogue #999-901-192 Counterbalance Valves, 3:1, 5:1, 1:1 and 2:1 Pilot Ratios, Vented Performance Curves Free Flow and Pilot Open Pressure Drop CWC*-L*N P = psi 300 200 Free Flow 100 Piloted Open 0 0 5 10 15 Q = GPM CWE*-L*N P = psi 300 200 Free Flow 100 Piloted Open 0 0 10 20 30 Q = GPM CWG*-L*N P = psi 300 200 Free Flow 100 Piloted Open 0 0 40 20 60 Q = GPM CWI*-L*N 300 P = psi Applications Sun counterbalance valves with pilot assist are used for load holding and to provide smooth motion control. When used with vertical actuators they help to ensure control of the load during lowering. With horizontal rotary motion, such as slewing, they can help provide good control of acceleration and deceleration. The vented type are used to provide load control on applications where there is a variable back-pressure downstream of the valve which could cause instability in a standard valve. The spring chamber is vented externally to tank through a fourth port making it insensitive to back pressure. Any pressure generated on the drain port will be additive to the setting. Counterbalance valves are load control valves and not speed control valves. Separate meter-in flow control valves should be included to provide speed control. It is always better to undersize rather than oversize the valve used and mount it as close to the actuator as possible. It is always advisable to set the pressure setting of a counterbalance valve before fitting it to the application as it is difficult to set up on a machine. It is always advisable to select a low pilot ratio to provide the best stability, particularly on cylinder applications. High pilot ratios should only be used on stable motor applications. Design Concepts and Features ■ All cartridges are fully tested and supplied at a standard setting. The setting of a counterbalance valve is always the cracking pressure. ■ The valve reseats after opening at 85% of the cracking pressure. ■ Maximum leakage on reseat is 5 drops/min. ■ The standard free reverse flow check varies between 20 psi and 45 psi depending on the frame size. ■ Recommended setting for counterbalance valves is 1.3 times the maximum load induced pressure. ■ Increase setting by turning adjust screw anti-clockwise. ■ The valve is opened by a combination of the load induced pressure on the main seat area and the pilot pressure on the pilot area. ■ The cartridge has a sealed pilot. ■ All cartridges have 3 nominal adjustment turns from minimum to maximum pressure setting. ■ A press fit tamper resistant cap is available to fit over the screw adjustment. ■ Valves are unaffected by back pressure at Port 2. ■ Vent port should not be blocked. 200 Free Flow 100 Piloted Open 0 0 40 80 120 Q = GPM General Application Requirements ■ ■ ■ ■ Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at cracking flow. US Selected Assemblies Catalogue #999-901-192 71 FOUR PORT COUNTERBALANCE TECHNICAL TIPS / PERFORMANCE CURVES FOUR PORT COUNTERBALANCE Line Mounted Assemblies FOUR PORT LOAD CONTROL APPLICATIONS (90 DEGREE BODIES) PILOT RATIO 3:1, 1:1 PILOT RATIO 4.5:1, 2:1 Go to www.sunhydraulics.com for more product information and pricing. 0-15 GPM 4 Cavity T-21A 3 2 1.25 .62 1 0 Ports 1 and 2 Ports 3 and 4 Assembly Model Code* 3/8” NPTF 3: 3/8” NPTF 4: 1/4” NPTF CWC*-LHN-MAB 1/2” NPTF 3: 3/8” NPTF 4: 1/4” NPTF CWC*-LHN-MAC 3: SAE-6 4: SAE-6 CWC*-LHN-MAI 3: SAE-8 4: SAE-6 CWC*-LHN-MAJ 3: SAE-8 4: SAE-6 CWC*-LHN-MAK SAE-6 SAE-8 SAE-10 Mounting Holes: .34 diameter through hole 2 places. 0 .38 2 L Control 1.66 Max. 4 1 1.25 Ports 3 and 4 Assembly Model Code* 3/8” NPTF 3: 3/8” NPTF 4: 1/4” NPTF CWC*-LGN-MAB 1/2” NPTF 3: 3/8” NPTF 4: 1/4” NPTF CWC*-LGN-MAC SAE-6 3: SAE-6 4: SAE-6 CWC*-LGN-MAI SAE-8 3: SAE-8 4: SAE-6 CWC*-LGN-MAJ SAE-10 3: SAE-8 4: SAE-6 CWC*-LGN-MAK 3 2.50 0 .44 1.59 2.56 3.12 3.56 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-30 GPM 4 Ports 1 and 2 Cavity T-22A 3 2 1.50 .75 1 0 Ports 1 and 2 Ports 3 and 4 Assembly Model Code* 1/2” NPTF 3: 1/2” NPTF 4: 1/4” NPTF CWE*-LHN-NAC 3/4” NPTF 3: 1/2” NPTF 4: 1/4” NPTF CWE*-LHN-NAD 3: SAE-8 4: SAE-6 CWE*-LHN-NAJ 3: SAE-10 4: SAE-6 CWE*-LHN-NAK SAE-8 SAE-10 0 Mounting Holes: .42 diameter through hole 2 places. 2 .50 1.50 4 L Control 1.98 Max. 1 Ports 1 and 2 Ports 3 and 4 Assembly Model Code* 1/2” NPTF 3: 1/2” NPTF 4: 1/4” NPTF CWE*-LGN-NAC 3/4” NPTF 3: 1/2” NPTF 4: 1/4” NPTF CWE*-LGN-NAD SAE-8 3: SAE-8 4: SAE-6 CWE*-LGN-NAJ SAE-10 3: SAE-10 4: SAE-6 CWE*-LGN-NAK 3 3.00 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .44 1.72 2.69 3.31 3.75 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 70 for cartridge models CW**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 72 US Selected Assemblies Catalogue #999-901-192 FOUR PORT COUNTERBALANCE Line Mounted Assemblies FOUR PORT LOAD CONTROL APPLICATIONS (90 DEGREE BODIES) PILOT RATIO 3:1, 1:1 PILOT RATIO 5:1, 2:1 Go to www.sunhydraulics.com for more product information and pricing. 3 0-60 GPM Cavity T-23A 2 4 G 1 2.25 1.13 0 Ports 1 and 2 Ports 3 and 4 Assembly Model Code* 1” NPTF 3: 3/4” NPTF 4: 1/4” NPTF CWG*-LHN-PAE 0 1 1/4” NPTF 3: 3/4” NPTF 4: 1/4” NPTF CWG*-LHN-PAF .75 SAE-12 3: SAE-12 4: SAE-6 CWG*-LHN-PAL 2.00 SAE-16 3: SAE-12 4: SAE-6 CWG*-LHN-PAM Mounting Holes: .42 diameter through hole, 2 places. 2 L Control 2.16 Max. 4 1 Ports 1 and 2 Ports 3 and 4 Assembly Model Code* 1” NPTF 3: 3/4” NPTF 4: 1/4” NPTF CWG*-LGN-PAE 1 1/4” NPTF 3: 3/4” NPTF 4: 1/4” NPTF CWG*-LGN-PAF SAE-12 3: SAE-12 4: SAE-6 CWG*-LGN-PAL SAE-16 3: SAE-12 4: SAE-6 CWG*-LGN-PAM 3 G 4.00 0 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.09 2.12 0-120 GPM 4 3.41 4.25 4.75 1/4” NPTF Gauge Port *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-24A 3 2 3.00 1.50 1 0 Ports 1 and 2 Ports 3 and 4 Assembly Model Code* 1” NPTF 1/4” NPTF CWI*-LHN-QCE 1 1/4” NPTF 1/4” NPTF CWI*-LHN-QCF SAE-16 SAE-6 CWI*-LHN-QCM SAE-20 SAE-6 CWI*-LHN-QCN Mounting Holes: .42 diameter through hole, 2 places. 0 .50 2 4 L Control 2.61 Max. 1 2.50 Ports 1 and 2 Ports 3 and 4 Assembly Model Code* CWI*-LGN-QCE 1” NPTF 1/4” NPTF 1 1/4” NPTF 1/4” NPTF CWI*-LGN-QCF SAE-16 SAE-6 CWI*-LGN-QCM SAE-20 SAE-6 CWI*-LGN-QCN 3 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.00 0 2.50 4.28 5.31 5.88 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 70 for cartridge models CW**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 73 FOUR PORT COUNTERBALANCE Line Mounted Assemblies FOUR PORT LOAD CONTROL APPLICATIONS (2.00” SAE C62 FLANGE PORT BODY, 2 CAVITIES) PILOT RATIO 3:1, 1:1 0-240 GPM 4 Cavity T-24A 3 2 0 2.26 7.78 0 0 4 1.06 1 Ports 1 and 2 2” SAE C62 PILOT RATIO 4:5:1, 2:1 Go to www.sunhydraulics.com for more product information and pricing. Ports 3 and 4 SAE-6 2.97 Assembly Model Code* CWI*-LHN-Z9T 4.88 3 5.94 0 Mounting Holes: .500-13 UNC-2B x .87 DP. 0 4.97 0 2.97 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1 6.75 8.34 Ports 1 and 2 Ports 3 and 4 Assembly Model Code* 2” SAE C62 SAE-6 CWI*-LGN-Z9T L Control 2.58 Max. 2 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.94 NOTES: Page 70 for cartridge models CW**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 74 US Selected Assemblies Catalogue #999-901-192 FOUR PORT COUNTERBALANCE Line Mounted Assemblies FOUR PORT LOAD CONTROL APPLICATIONS (90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES, COMMON PORT 4) PILOT RATIO 3:1, 1:1 2A PILOT RATIO 5:1, 2:1 Go to www.sunhydraulics.com for more product information and pricing. 0-15 GPM 2B Cavity T-21A 1.25 4 .62 1A 0 1B Ports 1A, 1B, 2A & 2B Port 4 Assembly Model Code* 3/8” NPTF 1/4” NPTF CWC*-LHN-XPB 1/2” NPTF 1/4” NPTF CWC*-LHN-XPC SAE-6 SAE-6 SAE-8 SAE-10 Mounting Holes: .34 diameter through holes, 2 places. Ports 1A, 1B, 2A & 2B Port 4 Assembly Model Code* 3/8” NPTF 1/4” NPTF CWC*-LFN-XPB 1/2” NPTF 1/4” NPTF CWC*-LFN-XPC CWC*-LHN-XPI SAE-6 SAE-6 CWC*-LFN-XPI SAE-6 CWC*-LHN-XPJ SAE-8 SAE-6 CWC*-LFN-XPJ SAE-6 CWC*-LHN-XPK SAE-10 SAE-6 CWC*-LFN-XPK *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2A 0 .38 2B 1B 1.25 1A 2.75 2A 3.62 4.00 0 .50 1.59 0-30 GPM 2B L Control 1.66 Max. 4 3.12 3.56 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-22A 2.00 4 1.00 1A 1B 0 Ports 1A, 1B, 2A & 2B Port 4 Assembly Model Code* 1/2” NPTF 1/4” NPTF CWE*-LHN-XIC 3/4” NPTF 1/4” NPTF CWE*-LHN-XID SAE-6 SAE-6 SAE-8 SAE-6 0 .75 Mounting Holes: .42 diameter through hole, 2 places. 2B 4 L Control 1.98 Max. Ports 1A, 1B, 2A & 2B Port 4 Assembly Model Code* 1/2” NPTF 1/4” NPTF CWE*-LFN-XIC 3/4” NPTF 1/4” NPTF CWE*-LFN-XID CWE*-LHN-XII SAE-6 SAE-6 CWE*-LFN-XII CWE*-LHN-XIJ SAE-8 SAE-6 CWE*-LFN-XIJ 1.62 3.38 1B 1A 2A 4.25 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.00 0 .50 1.72 3.31 4.00 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 70 for cartridge models CW**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. US Selected Assemblies Catalogue #999-901-192 75 FOUR PORT COUNTERBALANCE Line Mounted Assemblies FOUR PORT LOAD CONTROL APPLICATIONS (90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES, COMMON PORT 4) PILOT RATIO 3:1, 1:1 2A PILOT RATIO 5:1, 2:1 Go to www.sunhydraulics.com for more product information and pricing. 0-60 GPM 2B Cavity T-23A 2.00 4 1.00 1A Ports 1A 1B, 2A & 2B 1B 0 Assembly Model Code* Port 4 1” NPTF 1/4” NPTF CWG*-LHN-XME 1 1/4” NPTF 1/4” NPTF CWG*-LHN-XMF SAE-12 1/4” NPTF CWG*-LHN-XML SAE-16 1/4” NPTF CWG*-LHN-XMM Mounting Holes: .42 diameter through hole, 2 places. 0 .75 2B 1B 1.62 1A 3.38 2A 5.00 0 .50 1.72 0-120 GPM 2B Ports 1A 1B, 2A & 2B Port 4 Assembly Model Code* CWG*-LFN-XME 1” NPTF 1/4” NPTF 1 1/4” NPTF 1/4” NPTF CWG*-LFN-XMF SAE-12 1/4” NPTF CWG*-LFN-XML SAE-16 1/4” NPTF CWG*-LFN-XMM 2A 4.25 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 1.98 Max. 4 3.31 4.00 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-24A 3.00 4 1.50 1A Ports 1A 1B, 2A & 2B Port 4 1B 0 Assembly Model Code* 1” NPTF 1/4” NPTF CWI*-LHN-XLE 1 1/4” NPTF 1/4” NPTF CWI*-LHN-XLF *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Mounting Holes: .42 diameter through hole, 2 places. 0 .62 2B 2.12 1B 4.88 1A 4 L Control 2.58 Max. Ports 1A 1B, 2A & 2B Port 4 Assembly Model Code* 1” NPTF 1/4” NPTF CWI*-LFN-XLE 1 1/4” NPTF 1/4” NPTF CWI*-LFN-XLF 2A 6.38 7.00 0 .62 2.62 5.44 6.00 *The asterisk (*) shown in the fourth digit of the model code indicates the counterbalance pilot ratio of the cartridge and must be specified by customer. See page 70. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 70 for cartridge models CW**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 76 US Selected Assemblies Catalogue #999-901-192 Three Port Pilot-to-Open Check Assemblies Cartridge Type 2 Page 3 Pilot Operated 78 1 Line Mounted Assemblies (Body Type) 2 3 1 V1 90 Degree Inline 90 Degree 2” SAE C61/C62 Flange Port, 2 Cavities 80 82 84 90 Degree Cross-Piloted, 2 Cavities 85 Inline Cross-Piloted, 2 Cavities 88 Direct Mount .75”/1.00”/1.25” SAE C61 Flange Port/ Gasket Mount, Through Pilot Port Direct Mount .75”/1.00”/1.25” SAE C62 Flange Port/ Gasket Mount, Through Pilot Port 89 Gasket Mount 91 Gasket Mount, 2 Cavities 92 V2 C1 C2 V1 V2 C1 C2 3 3 2 1 V2 90 V1 C1 C2 V1 C1 V2 C2 US Selected Assemblies Catalogue #999-901-192 77 THREE PORT PILOT-TO-OPEN CHECK Pilot-to-Open Check Valves PILOT OPERATED Ext. Full Adjustment 5 Turns + - 2 L Control 3 2 3 X Control b c 3 Pilot Locating Shoulder 2 Valve Load 1 a 1 1 X, L Controls B, E, P Controls Cartridge Dimensions c b X,B,E,P Capacity Typical Cartridge Model Code 7.5 GPM CKBB – XCN T - 163A 1.22 3/4” 1.25 2.55 Installation Torque (lb. ft.) 25/30 15 GPM CKCB – XCN T - 11A 1.38 7/8” 1.19 2.50 30/35 30 GPM CKEB – XCN T - 2A 1.38 1 1/8” 1.38 2.81 45/50 60 GPM CKGB – XCN T - 17A 1.81 1 1/4” 1.81 3.28 150/160 120 GPM CKIB – XCN T - 19A 2.50 1 5/8” 2.31 3.94 350/375 Cavity a L OPTION ORDERING INFORMATION CK ✱ ✱ Nominal Capacity Version – ✱✱✱ Control** Cracking Pressure Seal B *7.5 GPM B Bleed through Pilot X Standard Pilot A 4 psi N Buna-N C 15 GPM D Sealed Pilot Piston L Manual Load Release B 15 psi V Viton E 30 GPM G 60 GPM I 120 GPM B 1/4" BSPP External Pilot Port 3 blocked E SAE-4 External Pilot Port 3 blocked P 1/4" NPTF External Pilot Port 3 blocked ** See page 244 for information on Control Options 78 C 30 psi D 50 psi E 75 psi F 100 psi *CKBB, CKBD available with C and E Cracking Pressure Only. US Selected Assemblies Catalogue #999-901-192 THREE PORT PILOT-TO-OPEN CHECK TECHNICAL TIPS / PERFORMANCE CURVES Pilot-to-Open Check Valves, External Pilot, Non-vented Note: Pressure at port 2 is directly additive to the pilot pressure required at port 3 (pilot). For applications where this occurs, a 4 port vented pilot operated check cartridge (CV*V-***) should be considered. Performance Curves Typical Pressure Drop CKCB-X*N 480 480 400 300 400 210 140 XEN 70 XCN 0 2.5 5 P = psi P = psi CKBB-X*N OT PIL LL FU 7.5 Flow = GPM 140 480 400 300 210 OT PIL LL FU XEN XCN 0 7.5 15 22.5 Flow = GPM 300 210 140 70 30 0 400 300 210 OT PIL LL FU XEN XCN 40 80 120 160 Flow = GPM General Application Requirements ■ ■ ■ ■ Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at cracking flow. US Selected Assemblies Catalogue #999-901-192 79 20 XCN 480 0 15 OT PIL LL FU XEN CKIB-X*N 140 70 10 CKGB-X*N 400 70 5 Flow = GPM 480 140 OT PIL LL FU XEN XCN 0 10 P = psi P = psi 300 210 70 CKEB-X*N P = psi Applications Pilot operated checks are used to hold loads in position and for that reason should be mounted as close to the actuator as possible. Pilot-to-open checks are non-modulating, on/off devices that allow free flow through the check valve from port 2 (valve) to port 1 (load). Reverse flow is blocked until a pilot pressure directly proportional to the load pressure is sensed at port 3 (pilot), so that a pilot piston displaces the check from its seat. Design Concepts and Features ■ 3:1 pilot ratio is suitable for most applications. ■ Low leakage when closed, less than 1 drop/min. ■ Optional, emergency manual release screw, in case pilot pressure is not available. ■ Pilot piston leakage is present on CK*B models between port 3 and port 2 in order to purge trapped air in the pilot line. Optional models (CK*D) feature a sealed pilot piston for applications where cross-port leakage is undesirable. 20 40 60 Flow = GPM 80 THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (90 DEGREE BODIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-7.5 GPM 2 Cavity T-163A 3 1.00 .50 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 1/4” NPTF 1/4” NPTF CKBB-XCN-JCA 3/8” NPTF 1/4” NPTF CKBB-XCN-JCB SAE-4 SAE-4 CKBB-XCN-JCH SAE-6 SAE-4 CKBB-XCN-JCI Mounting Holes: .28 diameter through hole 2 places. 0 .28 L Control 1.91 Max. 2 1 .97 3 2.00 1.31 0 2.14 2.59 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-15 GPM 2 Cavity T-11A 3 1.25 .62 0 1 Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 1/4” NPTF CKCB-XCN-ECB 1/2” NPTF 1/4” NPTF CKCB-XCN-ECC SAE-4 SAE-4 CKCB-XCN-ECH SAE-6 SAE-6 CKCB-XCN-ECI SAE-8 SAE-6 CKCB-XCN-ECJ Mounting Holes: .34 diameter through hole 2 places. 0 .38 L Control 1.81 Max. 2 1 1.25 3 2.50 1.56 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.53 3.00 0-30 GPM 2 3 Cavity T-2A 1.50 .75 0 1 Ports 1 and 2 Port 3 Assembly Model Code* 1/2” NPTF 1/4” NPTF CKEB-XCN-BCC 3/4” NPTF 1/4” NPTF CKEB-XCN-BCD SAE-6 SAE-6 CKEB-XCN-BCI SAE-8 SAE-6 CKEB-XCN-BCJ 0 Mounting Holes: .42 diameter through hole 2 places. 2.02 Max. 2 .50 1 1.62 L Control 3 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.00 0 1.72 2.66 3.25 NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 80 US Selected Assemblies Catalogue #999-901-192 THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (90 DEGREE BODIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-60 GPM 2 Cavity T-17A 3 2.25 2.12 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF CKGB-XCN-HCE 1 1/4” NPTF 1/4” NPTF CKGB-XCN-HCF SAE-12 SAE-6 CKGB-XCN-HCL SAE-16 SAE-6 CKGB-XCN-HCM 0 Mounting Holes: .42 diameter through hole 2 places. L Control 2.16 Max. 2 .75 1 2.00 3 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.12 0 0-120 GPM 2 3.50 4.25 Cavity T-19A 3 3.00 1.50 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1/4” NPTF CKIB-XCN-KCE 1 1/4” NPTF 1/4” NPTF CKIB-XCN-KCF SAE-16 SAE-6 CKIB-XCN-KCM SAE-20 SAE-6 CKIB-XCN-KCN 0 .50 Mounting Holes: .42 diameter through hole 2 places. L Control 2.78 Max. 2 1 2.25 3 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 2.47 4.25 5.00 NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 81 THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (INLINE BODIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-7.5 GPM 2 Cavity T-163A 3 Mounting Holes: .28 diameter through 2 places. Counterbore for 1/4 bolt. 1 Ports 1 and 2 Port 3 1/4” NPTF 1/4” NPTF CKBB-XCN-JJA 3/8” NPTF 1/4” NPTF CKBB-XCN-JJB L Control 1.25 Max. Assembly Model Code* SAE-4 SAE-4 CKBB-XCN-JJH SAE-6 SAE-4 CKBB-XCN-JJI 2.64 1.94 3 1.28 1.25 2 .64 0 1.62 1.12 0 1 0 0 3.38 0 2.13 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-15 GPM 2 Cavity T-11A 3 Mounting Holes: .34 diameter through 2 places. Counterbore for 5/16 bolt. 1 L Control 1.81 Max. Ports 1 and 2 Port 3 Assembly Model Code* 2.64 3/8” NPTF 1/4” NPTF CKCB-XCN-EJB 2.05 SAE-6 SAE-6 CKCB-XCN-EJI SAE-8 SAE-6 3 1.25 1.28 CKCB-XCN-EJJ 2 .66 0 1.78 1.16 .31 0 1 0 0 0 .29 1.26 3.38 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 82 US Selected Assemblies Catalogue #999-901-192 THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (INLINE BODIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-30 GPM 2 Cavity T-2A 3 Mounting Holes: .34 diameter through hole Counterbore for hex head bolt. 2 places. 1 L Control 2.09 Max. Ports 1 and 2 Port 3 Assembly Model Code* 1/2” NPTF 3.22 1/4” NPTF CKEB-XCN-BVC 2.56 3/4” NPTF 1/4” NPTF CKEB-XCN-BVD SAE-6 SAE-6 CKEB-XCN-BVI SAE-8 SAE-6 CKEB-XCN-BVJ 3 1.68 1.66 2 .88 0 2.12 1.34 1 0 .31 0 0 0 1.44 3.88 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-60 GPM 2 Cavity T-17A 3 Mounting Holes: .42 diameter through hole. 1.00 diameter counterbore. 2 places. 1 L Control 2.37 Max. Ports 1 and 2 Port 3 Assembly Model Code* 3.88 3/4” NPTF 1/4” NPTF CKGB-XCN-HDD 3.16 1” NPTF 1/4” NPTF CKGB-XCN-HDE 2.28 SAE-12 SAE-6 CKGB-XCN-HDL SAE-16 SAE-6 CKGB-XCN-HDM 3 2.28 2 .94 0 3.00 1.69 .38 0 1 0 0 0 .38 1.96 4.62 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 83 THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (90 DEGREE 2.00” SAE C61/C62 FLANGE PORT BODIES, 2 CAVITIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-240 GPM 2 Cavity T-19A 3 5.94 2.97 1 Ports 1 and 2 Port 3 Assembly Model Code* 2” SAE C61 SAE-6 CKIB-XCN-XZZ 0 Mounting Holes: .375-16 UNC-2B x 15,7 mm deep. 2 places. L Control 0 2.77 2 Max. .97 3 1 2.88 4.97 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 1.97 0-240 GPM 2 3 4.25 6.03 6.75 Cavity T-19A 5.94 2.97 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 2” SAE C62 SAE-6 CKIB-XCN-Z8Z Mounting Holes: .500-13 UNC-2B x .87 deep. 2 places. L Control 2.78 Max. 0 2 1.06 1 2.97 3 4.88 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.94 0 2.26 4.97 7.50 NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 84 US Selected Assemblies Catalogue #999-901-192 THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-7.5 GPM V1 V2 Cavity T-163A 1.00 .50 0 C1 Mounting Holes: .28 diameter through hole, 2 places. C2 0 Ports C1, C2, V1 & V2 Assembly Model Code* 1/4” NPTF CKBB-XCN-JYA 3/8” NPTF CKBB-XCN-JYB 1/2” NPTF CKBB-XCN-JYH SAE-6 CKBB-XCN-JYI 1.06 C1 2.44 C2 V2 3.12 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.50 .50 0 1.50 0-15 GPM V1 V2 L Control 1.94 Max. V1 .38 2.75 Cavity T-11A 1.25 .62 0 C1 Mounting Holes: .34 diameter through hole, 2 places. C2 0 .38 Ports C1, C2, V1 & V2 Assembly Model Code* 3/8” NPTF CKCB-XCN-YEB 1/2” NPTF CKCB-XCN-YEC SAE-6 CKCB-XCN-YEI SAE-8 CKCB-XCN-YEJ SAE-10 CKCB-XCN-YEK L Control 1.81 Max. V1 1.25 C1 2.75 C2 V2 3.62 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .50 1.56 3.00 NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 85 THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-30 GPM V1 V2 Cavity T-2A 1.50 .75 0 C1 C2 Mounting Holes: .42 diameter through hole, 2 places. 0 Ports C1, C2, V1 & V2 Assembly Model Code* 1/2” NPTF CKEB-XCN-YAC 3/4” NPTF CKEB-XCN-YAD SAE-8 CKEB-XCN-YAJ SAE-10 CKEB-XCN-YAK 1.50 C1 3.00 C2 V2 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.06 Max. V1 .50 L Control 4.50 0 .50 1.75 3.25 NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 86 US Selected Assemblies Catalogue #999-901-192 THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-60 GPM V1 Cavity T-17A V2 2.25 1.12 C1 0 C2 Ports C1, C2, V1 & V2 Assembly Model Code* 1” NPTF CKGB-XCN-YJE 1 1/4” NPTF CKGB-XCN-YJF SAE-12 CKGB-XCN-YJL SAE-16 CKGB-XCN-YJM Mounting Holes: .42 diameter through hole, 2 places. L Control 0 2.00 C1 4.50 C2 5.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V2 6.50 0 .75 2.09 0-120 GPM V1 V2 2.37 Max. V1 .75 4.00 Cavity T-19A 4.50 2.25 C1 0 C2 Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 4 places. Ports C1, C2, V1 & V2 Assembly Model Code* 1 1/2” SAE C62 CKIB-XCN-YM6 0 .52 V1 2.78 Max. C1 2.53 L Control C2 6.50 V2 8.52 9.03 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 2.41 4.94 NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 87 THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (INLINE CROSS-PILOTED BODIES, 2 CAVITIES) PILOT OPERATED ASSEMBLIES V1 C1 V2 Go to www.sunhydraulics.com for more product information and pricing. 0-15 GPM Cavity T-11A Mounting Holes: .34 diameter through hole .88 diameter socket clearance. 2 places. C2 L Control 1.81 Max. Ports C1, C2, V1 & V2 Assembly Model Code* 3/8” NPTF CKCB-XCN-XEB 2.05 SAE-6 CKCB-XCN-XEI 1.28 SAE-8 CKCB-XCN-XEJ 2.64 V1 V2 1.28 0 C2 V2 .66 0 0 0 .29 2.94 2.31 1.47 .62 0 3.10 3.38 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V1 C1 V2 0-30 GPM Cavity T-2A Mounting Holes: .34 diameter through hole .88 diameter socket clearance. 2 places. C2 L Control 2.09 Max. Ports C1, C2, V1 & V2 Assembly Model Code* 1/2” NPTF CKEB-XCN-XAC 2.56 CKEB-XCN-XAD 1.66 3/4” NPTF SAE-6 CKEB-XCN-XAI SAE-8 CKEB-XCN-XAJ 3.22 V1 V2 V2 .88 0 3.62 2.84 1.81 .78 0 1.66 C2 0 0 0 .28 3.59 3.88 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 88 US Selected Assemblies Catalogue #999-901-192 THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (DIRECT MOUNT .75”/1.00”/1.25” SAE C61 FLANGE PORT/GASKET MOUNT BODIES, THROUGH PILOT PORT) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-30 GPM 3 3 2 1 Cavity T-2A 2.50 1.25 0 Ports 1 and 2 Port 3 Assembly Model Code* 3/4” SAE C61 SAE-6 CKEB-XCN-ZNV .75 SAE Code 61 4-Bolt Flange Pattern, 2 places. X Control 2 holes tapped, 4 holes through .50 Max. 0 2 3 1.25 1 2.25 0 1.03 1.91 0-60 GPM 3 3 2 1 2.84 3.50 -214 O-ring *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-17A 3.00 1.50 Ports 1 and 2 Port 3 Assembly Model Code* 1” SAE C61 SAE-6 CKGB-XCN-ZNW 0 1.00 SAE Code 61 4-Bolt Flange Pattern, 2 places. X Control 2 holes tapped, 4 holes through .87 Max 0 2 1.13 3 1 2.94 0 1.16 2.19 -219 O-ring *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-120 GPM 3 3 2 1 3.50 4.13 Cavity T-19A 3.50 1.75 0 Ports 1 and 2 Port 3 Assembly Model Code* 1 1/4” SAE C61 SAE-6 CKIB-XCN-ZNX 1.25” SAE Code 61 4-Bolt Flange Pattern, 2 places. Port 1 through hole. X Control Port 2 tapped hole. 1.13 Max. 0 2 3 1.72 1 3.44 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.44 2.62 -222 O-ring 4.81 5.50 NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. US Selected Assemblies Catalogue #999-901-192 89 THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (DIRECT MOUNT .75”/1.00”/1.25” C62 FLANGE PORT/GASKET MOUNT BODIES, THROUGH PILOT/DRAIN PORT) PILOT OPERATED ASSEMBLIES Go to www.sunhydraulics.com for more product information and pricing. 0-30 GPM 3 3 2 1 Cavity T-2A 3.00 1.50 Ports 1 and 2 Port 3 Assembly Model Code* 3/4” SAE C62 SAE-6 CKEB-XCN-ZDS 0 .75” SAE Code 62 4-Bolt Flange Pattern, 2 places. Port 1 through hole. Port 2 tapped hole. L Control 0 2.09 Max. 2 1.22 3 1 2.44 1.19 0 2.12 0-60 GPM 3 3 2 1 3.03 3.53 -214 O-ring *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-17A 3.50 1.75 Ports 1 and 2 Port 3 Assembly Model Code* 1” SAE C62 SAE-6 CKGB-XCN-ZDR 0 1.00” SAE Code 62 4-Bolt Flange Pattern, 2 places. Port 1 through hole. Port 2 tapped hole. 0 L Control 2.34 Max. 2 3 1.72 1 3.44 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.38 2.47 -219 O-ring 0-120 GPM 3 3 2 1 3.69 4.31 Cavity T-19A 4.00 2.00 0 Ports 1 and 2 Port 3 Assembly Model Code* 1 1/4” SAE C62 SAE-6 CKIB-XCN-ZFD 1.25” SAE Code 62 4-Bolt Flange Pattern, 2 places. Port 1 through hole. Port 2 tapped hole. 0 L Control 2.75 Max. 2 1.97 3 1 3.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 1.53 2.78 4.88 5.62 -222 O-ring NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 90 US Selected Assemblies Catalogue #999-901-192 THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (GASKET MOUNT BODIES) PILOT OPERATED ASSEMBLIES V2 Go to www.sunhydraulics.com for more product information and pricing. 0-15 GPM V1 Cavity T-11A 0 .59 C1 1.19 C2 -113 O-ring Mounting Holes: .34 diameter through hole, counterbore .50 diameter x .25 deep. 2 places. Ports C1, C2, V1 & V2 Assembly Model Code* 3/8” NPTF CKCB-XCN-ZTN 2.50 CKCB-XCN-ZTC 2.00 SAE-6 L Control 1.81 Max. V1 1.63 1.03 .81 .50 .31 0 V2 C2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V2 C1 0 3.75 1.00 0-30 GPM V1 Cavity T-2A 0 .72 C1 1.44 -117 O-ring C2 Ports C1, C2, V1 & V2 Assembly Model Code* 1/2” NPTF CKEB-XCN-ZTF SAE-8 CKEB-XCN-ZTG Mounting Holes: .42 diameter through hole, 2 places. 3.00 L Control 1.63 Max. V1 2.38 1.94 1.22 .94 .63 .34 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V2 V2 0 C1 C2 1.22 4.25 0-60 GPM V1 Cavity T-17A 0 1.09 C1 2.19 C2 Ports C1, C2, V1 & V2 Assembly Model Code* 3/4” NPTF CKGB-XCN-ZTJ SAE-12 CKGB-XCN-ZTK -121 O-ring Mounting Holes: .53 diameter through hole, counterbore .78 diameter L Control x .44 deep. 2 places. 4.00 2.22 Max. V1 3.25 2.69 1.56 C1 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. C2 V2 1.06 .44 0 0 5.47 1.44 NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, a7nd options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 91 THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS (GASKET MOUNT BODIES, 2 CAVITIES) PILOT OPERATED ASSEMBLIES V1 Go to www.sunhydraulics.com for more product information and pricing. 0-15 GPM V2 Cavity T-11A 0 C2 2.12 Max. 1.69 C1 C2 2.19 -113 O-ring Ports C2, V1 & V2 Assembly Model Code* 3/8” NPTF SAE-6 CKCB-XCN-YVM CKCB-XCN-YVY Mounting Holes: (opposite side) .34 diameter through hole, counterbore .50 diameter x .25 deep. 2 places. L Control 2.50 2.12 Max. V1 2.00 1.62 C1 V2 1.03 .78 .31 C2 0 *Add modifier /S to order SG Iron for pressure rating over . V1 0 1.00 0-30 GPM V2 3.75 Cavity T-2A 0 .81 1.75 Max. C1 C2 2.75 -117 O-ring Ports C2, V1 & V2 Assembly Model Code* 1/2” NPTF SAE-8 CKEB-XCN-YVW CKEB-XCN-YVV Mounting Holes: .41 diameter through hole, 2 places. L Control 1.75 Max. 3.00 V1 2.38 1.94 V2 C1 C2 1.22 1.00 .34 *Add modifier /S to order SG Iron for pressure rating over . V1 0 0 1.22 0-60 GPM V2 4.25 Cavity T-17A 0 2.22 Max. C1 C2 Ports C2, V1 & V2 Assembly Model Code* 3/4” NPTF SAE-12 CKEB-XCN-YVT CKEB-XCN-YVS -121 O-ring Mounting Holes: (opposite side) .53 diameter through hole, counterbore .78 diameter x .44 deep. 2 places. 4.00 L Control 2.22 Max. V1 2.69 C2 V2 C1 *Add modifier /S to order SG Iron for pressure rating over . 1.56 .44 0 0 1.44 NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 92 US Selected Assemblies Catalogue #999-901-192 Four Port Pilot-to-Open Check Assemblies Cartridge Type 2 Page 3 Vented, 4 Port Cavity 94 4 1 Line Mounted Assemblies (Body Type) 2 3 90 Degree 96 90 Degree with Gauge Port 97 2.00” SAE C62 Flange Port, 2 Cavities 98 90 Degree Cross-Piloted, 2 Cavities, Common Port 4 99 4 1 2 3 G 4 1 2 3 4 1 2A 2B 4 1A 1B US Selected Assemblies Catalogue #999-901-192 93 FOUR PORT PILOT-TO-OPEN CHECK Pilot-to-Open Check Valves VENTED, 4 PORT CAVITY 2 3 Capacity 4 1 Typical Cartridge Model Code Cavity Cartridge Dimensions c b X a L Installation Torque (lb. ft.) 30/35 15 GPM CVCV – XCN T - 21A 1.38 7/8” 2.11 2.34 30 GPM CVEV – XCN T - 22A 1.38 1 1/8” 2.34 2.56 45/50 60 GPM CVGV – XCN T - 23A 1.81 1 1/4” 2.81 3.03 150/160 120 GPM CVIV – XCN T - 24A 2.50 1 5/8” 3.50 3.77 350/375 OPTION ORDERING INFORMATION CV ✱ V – ✱ ✱ ✱ Full Adjustment 5 Turns + - L Control X Control Nominal Capacity b c 4 Vent Cracking Pressure Seal C 15 GPM X Standard Pilot A 4 psi N Buna-N E 30 GPM L Manual Load Release B 15 psi V Viton G 60 GPM I 3 Pilot Control** C 30 psi D 50 psi 120 GPM Locating Shoulder E 75 psi F 100 psi 2 Valve Load 1 a ** See page 244 for information on Control Options 94 US Selected Assemblies Catalogue #999-901-192 FOUR PORT PILOT-TO-OPEN CHECK TECHNICAL TIPS / PERFORMANCE CURVES Pilot-to-Open Check Valves, Vented Performance Curves Typical Pressure Drop CVCV-X*N P = psi 400 300 200 XEN 100 XCN 0 5 OT PIL LL FU 10 15 20 Flow = GPM CVEV-X*N P = psi 400 300 200 XEN 100 XCN 0 7.5 OT PIL LL FU 15 22.5 30 Flow = GPM CVGV-X*N P = psi 400 300 200 XEN 100 XCN 0 20 OT PIL LL FU 40 60 Flow = GPM 80 CVIV-X*N 400 P = psi Applications Sun pilot-to-open check valves are non-modulating, on/off valves used for load locking only, therefore do not provide smooth motion control. They allow free flow through check valve from port 2 to port 1, then block reverse flow until a pilot pressure directly proportional to the load pressure is sensed at port 3 so that a pilot piston can push the check poppet off of its seat. Because of the on/off action of the pilot-to-open check valve it makes them unsuitable for use with overrunning loads that will cause a loss of pilot pressure. Without pilot pressure the check valve will close until adequate pilot pressure is again restored, causing a ratcheting motion. Pilot-to-open check valves should never be used with paired cylinders. Pilot pressure will open the valve with the least load first, transferring the combined load to the second valve at double the pressure. The vented type is used on applications where there is variable back-pressure downstream of the valve which could cause instability in a standard valve. The pilot spring chamber is vented externally to tank through a fourth port making it insensitive to back pressure. Any pressure generated on the drain port will be additive to the pilot pressure required. NOTE: The vent port should never be plugged, as seal weepage will eventually cause valves to malfuntion. It is preferable that the pilot-to-open check valve is mounted as close as possible to the actuator to provide maximum protection in the event of a hydraulic line failure. This can be achieved by incorporating them directly into the actuator, or, Sun offers a range of gasket mounted bodies that bolt directly onto the mounting face of a cylinder or motor. Design Concepts and Features ■ Pilot-to-open check valves have a pilot ratio of 3:1, which is suitable for most applications. ■ Operating pressures up to 5000 psi. Flow capacities up to 120 GPM ■ Low leakage when closed, less than 1 drop/min. This leakage figure is checked at both low and high pressure during test. ■ Optional free flow check springs available, from 4 psi to avoid cavitation up to 100 psi for severe applications. ■ These cartridges have a sealed pilot piston. ■ Valve with emergency manual release screw available, in case pilot pressure is not available. ■ Hardened poppet and seat provides long life and better resistance to contamination. 300 200 XEN 100 XCN 0 40 OT PIL LL FU 80 120 160 Flow = GPM General Application Requirements ■ ■ ■ ■ Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at cracking flow. US Selected Assemblies Catalogue #999-901-192 95 FOUR PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies FOUR PORT PILOT-TO-OPEN CHECK APPLICATIONS (90 DEGREE BODIES) Go to www.sunhydraulics.com for more product information and pricing. VENTED 0-15 GPM 2 Cavity T-21A 3 4 1.25 .62 1 0 Ports 1 and 2 Ports 3 and 4 Assembly Model Code* 1/4” NPTF 3: 1/4” NPTF 4: 1/4” NPTF CVCV-XCN-MAA 3/8” NPTF 3: 3/8” NPTF 4: 1/4” NPTF CVCV-XCN-MAB 1/2” NPTF 3: 3/8” NPTF 4: 1/4” NPTF CVCV-XCN-MAC SAE-6 3: SAE-6 4: SAE-6 CVCV-XCN-MAI SAE-8 3: SAE-8 4: SAE-6 CVCV-XCN-MAJ SAE-10 3: SAE-8 4: SAE-6 CVCV-XCN-MAK 0 .38 Mounting Holes: .34 diameter through hole 2 places. 1.09 Max. 4 2 1 1.25 L Control 3 2.50 0 .44 1.59 2.56 3.12 3.56 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2 3 0-30 GPM Cavity T-22A 1.50 4 1 .75 0 Ports 1 and 2 Ports 3 and 4 Assembly Model Code* 3/8” NPTF 3: 3/8” NPTF 4: 1/4” NPTF CVEV-XCN-NAB 1/2” NPTF 3: 1/2” NPTF 4: 1/4” NPTF CVEV-XCN-NAC 3/4” NPTF 3: 1/2” NPTF 4: 1/4” NPTF CVEV-XCN-NAD SAE-8 3: SAE-8 4: SAE-6 CVEV-XCN-NAJ SAE-10 3: SAE-10 4: SAE-6 CVEV-XCN-NAK 0 Mounting Holes: .42 diameter through hole 2 places. 2 .50 1.50 4 1.25 Max. 1 3 L Control 3.00 0 .44 1.72 2.69 3.31 3.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 94 for cartridge model CV*V-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 96 US Selected Assemblies Catalogue #999-901-192 FOUR PORT PILOT-TO-OPEN CHECK APPLICATIONS (90 DEGREE BODIES) Go to www.sunhydraulics.com for more product information and pricing. VENTED 2 3 G 4 0-60 GPM Cavity T-23A 2.25 1.13 1 0 Ports 1 and 2 Ports 3 and 4 Assembly Model Code* 3/4” NPTF 3: 3/4” NPTF 4: 1/4” NPTF CVGV-XCN-PCD 1” NPTF 3: 3/4” NPTF 4: 1/4” NPTF CVGV-XCN-PCE 1 1/4” NPTF 3: 3/4” NPTF 4: 1/4” NPTF CVGV-XCN-PCF 3: SAE-12 4: SAE-6 CVGV-XCN-PCL 3: SAE-12 4: SAE-6 CVGV-XCN-PCM SAE-12 SAE-16 0 Mounting Holes: .42 diameter through hole, 2 places. 2 .75 2.00 1.41 Max. 4 1 L Control 3 G 4.00 0 1.09 2.12 3.41 4.25 4.75 1/4” NPTF Gauge Port *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2 3 0-120 GPM Cavity T-24A 3.00 G 4 1 Ports 1 and 2 1” NPTF 1 1/4” NPTF SAE-16 SAE-20 0 Ports 3 and 4 Assembly Model Code* 3: 1” NPTF 4: 1/4” NPTF 3: 1/4” NPTF 4: 1/4” NPTF 3: SAE-16 4: SAE-6 CVIV-XCN-QAE 3: SAE-16 4: SAE-6 1.50 CVIV-XCN-QAF Mounting Holes: .42 diameter through hole, 2 places. 0 .50 4 2 2.50 1.69 Max. 1 CVIV-XCN-QAM G CVIV-XCN-QAN L Control 5.00 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3 1.06 2.50 4.28 5.31 5.88 1/4” NPTF Gauge Port NOTES: Page 94 for cartridge model CV*V-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 97 FOUR PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies FOUR PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies FOUR PORT PILOT-TO-OPEN CHECK APPLICATIONS (2.00” SAE C62 FLANGE PORT BODY, 2 CAVITIES) Go to www.sunhydraulics.com for more product information and pricing. VENTED 0-240 GPM 2 Cavity T-24A 3 0 2.26 7.78 0 0 1.06 4 2.97 1 1 4.88 Ports 1 and 2 Ports 3 and 4 Assembly Model Code* 2” SAE C62 3: SAE-6 4: SAE-6 CVIV-XCN-Z9T 5.94 0 6.75 Mounting Holes: L Control .500-13 UNC-2B x (.87) DP. 0 4.97 8.34 1.69 Max. 0 2.97 2 3 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4 5.94 NOTES: Page 94 for cartridge model CV*V-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 98 US Selected Assemblies Catalogue #999-901-192 FOUR PORT PILOT-TO-OPEN CHECK APPLICATIONS (90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES, COMMON PORT 4) Go to www.sunhydraulics.com for more product information and pricing. VENTED 2A 0-15 GPM 2B Cavity T-21A 1.25 .62 4 1A 0 Mounting Holes: .34 diameter through holes, places. 1B Ports 1B, 2A & 2B Port 4 Assembly Model Code* 1/4” NPTF 1/4” NPTF CVCV-XCN-XPA 3/8” NPTF 1/4” NPTF CVCV-XCN-XPB 1/2” NPTF 1/4” NPTF CVCV-XCN-XPC SAE-6 SAE-6 CVCV-XCN-XPI SAE-8 SAE-6 CVCV-XCN-XPJ SAE-10 SAE-6 CVCV-XCN-XPK 0 .38 1.09 Max. 2B 1.25 1B 2.75 1A L Control 2A 3.62 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2A 0 .50 1.59 0-30 GPM 2B 4 3.12 3.56 Cavity T-22A 2.00 1.00 4 1A 0 Mounting Holes: .42 diameter through hole, 2 places. 1B Ports 1B, 2A & 2B Port 4 Assembly Model Code* 3/8” NPTF 1/4” NPTF CVEV-XCN-XIB 1/2” NPTF 1/4” NPTF CVEV-XCN-XIC 3/4” NPTF 1/4” NPTF CVEV-XCN-XID SAE-6 SAE-6 CVEV-XCN-XII SAE-8 SAE-6 CVEV-XCN-XIJ 0 .75 2B 1.62 1B 3.38 1A 2A 4.25 4 1.25 Max. L Control 5.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .50 1.72 3.31 4.00 NOTES: Page 94 for cartridge model CV*V-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. US Selected Assemblies Catalogue #999-901-192 99 FOUR PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies FOUR PORT PILOT-TO-OPEN CHECK Line Mounted Assemblies FOUR PORT PILOT-TO-OPEN CHECK APPLICATIONS (90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES, COMMON PORT 4) Go to www.sunhydraulics.com for more product information and pricing. VENTED 2A 0-60 GPM 2B Cavity T-23A 2.50 1.25 4 1A 0 Mounting Holes: .42 diameter through hole, 2 places. 1B 0 Ports 1A 1B, 2A & 2B Port 4 Assembly Model Code* .75 3/4” NPTF 1/4” NPTF CVGV-XCN-XMD 2.00 1” NPTF 1/4” NPTF CVGV-XCN-XME 1 1/4” NPTF 1/4” NPTF CVGV-XCN-XMF SAE-12 1/4” NPTF CVGV-XCN-XML SAE-16 1/4” NPTF CVGV-XCN-XMM 1.41 Max. 2B 4 1B L Control 4.50 1A 2A 5.75 6.50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2A 0 .75 2.38 0-120 GPM 2B 4.48 5.00 Cavity T-24A 3.00 1.50 4 1A Ports 1A 1B, 2A & 2B 0 Mounting Holes: .42 diameter through hole, 2 places. 1B Port 4 Assembly Model Code* 1” NPTF 1/4” NPTF CVIV-XCN-XLE 1 1/4” NPTF 1/4” NPTF CVIV-XCN-XLF 0 .62 2.12 1.69 Max. 2B 1B L Control 4.88 1A 2A 6.38 7.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4 0 .62 2.62 5.44 6.00 NOTES: Page 94 for cartridge model CV*V-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 100 US Selected Assemblies Catalogue #999-901-192 Check Assemblies Cartridge Type Page 2 1 to 2 Free Flow 102 2 to 1 Free Flow 102 1 2 1 Line Mounted Assemblies (Body Type) 2 90 Degree 104 90 Degree with Gauge Port 105 Inline Inline/Inline 1.50”/2.00” SAE C61 Flange Port 2.00” SAE C61/C62 Flange Port, 2 Port Cavity in Parallel 106 107 108 1 2 G 1 2 1 US Selected Assemblies Catalogue #999-901-192 101 CHECK Check Valves 1 TO 2 FREE FLOW 1 Cartridge Dimensions c a b X 10 GPM CXBA – XCN T - 162A 1.22 3/4” .82 Installation Torque (lb. ft.) 25/30 20 GPM CXDA – XCN T - 13A 1.38 7/8” .75 30/35 40 GPM CXFA – XCN T - 5A 1.62 1 1/8” .69 45/50 80 GPM CXHA – XCN T - 16A 2.44 1 1/4” .97 150/160 160 GPM CXJA – XCN T - 18A 3.13 1 5/8” 1.19 350/375 Capacity 2 Typical Cartridge Model Code Cavity OPTION ORDERING INFORMATION CX ✱ A – ✱ ✱ ✱ b Nominal Capacity c Locating Shoulder a B 10 GPM Control** X Non-adjustable Cracking Pressure Seal A 4 psi N Buna-N V Viton D 20 GPM B 15 psi F 40 GPM C 30 psi H 80 GPM D 50 psi J 160 GPM E 75 psi F 100 psi 2 Out In 1 ** See page 244 for information on Control Options 2 TO 1 FREE FLOW 2 1 Capacity 7.5 GPM CXAD – XCN T - 162A 1.22 3/4” .82 Installation Torque (lb. ft.) 25/30 15 GPM CXCD – XCN T - 13A 1.38 7/8” .75 30/35 CXED – XCN T - 5A 1.62 1 1/8” .69 45/50 60 GPM CXGD – XCN T - 16A 2.44 1 1/4” .97 150/160 120 GPM CXID – XCN T - 18A 3.13 1 5/8” 1.19 350/375 Nominal Capacity c A* 7.5 GPM Locating Shoulder C 15 GPM a Cavity 30 GPM OPTION ORDERING INFORMATION b CX ✱ D – ✱ ✱ ✱ Control** X Non-adjustable Cracking Pressure A 4 psi N Buna-N V Viton C 30 psi G 60 GPM D 50 psi I E 75 psi 120 GPM Seal B 15 psi E 30 GPM F 100 psi 2 In Out 1 Cartridge Dimensions c a b X Typical Cartridge Model Code ** See page 244 for information on Control Options 102 *CXAD available with A,C,E Cracking Pressures Only. US Selected Assemblies Catalogue #999-901-192 TECHNICAL TIPS / PERFORMANCE CURVES Check Valves, Free Flow, Port 1 to 2 CHECK Performance Curves Typical Pressure Rise CXBA-X*N CXDA-X*N 200 200 100 XEN 50 150 P = psi P = psi 150 XCN 100 XEN 50 XCN XAN 0 2.5 CXFA-X*N XAN 5 7.5 10 Flow = GPM 0 5 CXHA-X*N 10 15 Flow = GPM 20 200 200 150 100 P = psi P = psi Applications Check valves are used to provide free flow in one direction and blocked flow in the opposite direction. The preferred check CX*A-X*N (free flow 1 to 2) should be used wherever possible. Design Concepts and Features ■ Hardened and lapped sealing surfaces provide low leakage (less than 1 drop / min.) and long life. ■ Extensive range of spring options. ■ Available in five frame sizes with operating pressures to 5000 psi. XEN 50 150 100 XCN XAN 0 10 CXJA-X*N XEN 50 XCN XAN 20 30 40 100 150 200 Flow = GPM 0 25 50 75 Flow = GPM 100 P = psi 200 150 100 XEN 50 XCN XAN 0 50 Flow = GPM Check Valves, Free Flow, Port 2 to 1 Performance Curves Typical Pressure Rise CXAD-X*N CXCD-X*N 200 300 150 100 P = psi P = psi Applications The CX*D-X*N non-preferred check (free flow 2 to 1) should only be used to simplify complex manifold designs. Design Concepts and Features ■ Hardened and lapped sealing surfaces provide low leakage (less than 1 drop / min.) and long life. ■ Extensive range of spring options. ■ Available in five frame sizes with operating pressures to 5000 psi. XEN 50 XCN 200 XEN 100 XCN XAN 0 2.5 XAN 5 7.5 10 0 5 Flow = GPM CXED-X*N P = psi P = psi 200 XEN 100 0 200 XEN 100 XCN XAN XAN 7.5 CXID-X*N 15 22.5 80 120 Flow = GPM 30 0 P = psi 300 200 XEN 100 XCN XAN 0 40 160 Flow = GPM General Application Requirements ■ ■ Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at a crack flow rate. US Selected Assemblies Catalogue #999-901-192 103 20 300 XCN ■ 15 CXGD-X*N 300 ■ 10 Flow = GPM 20 40 60 Flow = GPM 80 CHECK Line Mounted Assemblies TWO PORT FLOW CONTROL APPLICATIONS (90 DEGREE BODIES) FREE FLOW Port 1 to Port 2 FREE FLOW Port 2 to Port 1 Go to www.sunhydraulics.com for more product information and pricing. 0-10 GPM 2 Cavity T-162A 0-8 GPM 2 1.00 .50 0 1 Ports 1 and 2 Assembly Model Code* 1/4” NPTF CXBA-X*N-AAA 3/8” NPTF CXBA-X*N-AAB SAE-4 CXBA-X*N-AAH SAE-6 CXBA-X*N-AAI 1 0 .50 X Control .79 Max. 2 1/4” NPTF CXAD-X*N-AAA 3/8” NPTF CXAD-X*N-AAB SAE-4 CXAD-X*N-AAH SAE-6 CXAD-X*N-AAI *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.50 0 0-20 GPM 28 1 33 2 00 Cavity T-13A 0-16 GPM 1.25 2 Assembly Model Code* 1 1.22 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports 1 and 2 Mounting Hole: .28 diameter through hole 2 .62 1 1 0 Ports 1 and 2 Assembly Model Code* Mounting Hole: .34 diameter through hole 1/4” NPTF CXDA-X*N-GAA 0 3/8” NPTF CXDA-X*N-GAB .28 SAE-4 CXDA-X*N-GAH SAE-6 CXDA-X*N-GAI SAE-8 CXDA-X*N-GAJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.00 Ports 1 and 2 X Control .72 Max. 2 1 1/4” NPTF CXCD-X*N-GAA 3/8” NPTF CXCD-X*N-GAB SAE-4 CXCD-X*N-GAH SAE-6 CXCD-X*N-GAI SAE-8 CXCD-X*N-GAJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.62 0-40 GPM Cavity T-5A 0-31 GPM 1.50 2 Assembly Model Code* 2 .75 1 1 0 Ports 1 and 2 Assembly Model Code* 3/8” NPTF CXFA-X*N-DAB 0 1/2” NPTF CXFA-X*N-DAC .38 SAE-6 CXFA-X*N-DAJ SAE-6 CXED-X*N-DAJ SAE-8 CXFA-X*N-DAK SAE-8 CXED-X*N-DAK Mounting Hole: .42 diameter through hole 1.25 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2 X Control .63 Max. Ports 1 and 2 Assembly Model Code* 3/8” NPTF CXED-X*N-DAB 1/2” NPTF CXED-X*N-DAC 1 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.00 NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 104 US Selected Assemblies Catalogue #999-901-192 Line Mounted Assemblies CHECK TWO PORT FLOW CONTROL APPLICATIONS (90 DEGREE BODIES) FREE FLOW Port 1 to Port 2 FREE FLOW Port 2 to Port 1 Go to www.sunhydraulics.com for more product information and pricing. 0-80 GPM 2 Cavity T-16A 0-60 GPM 2 2.25 1.12 G G 0 1 1 1/4” NPTF Gauge Port Mounting Hole: .42 diameter through hole Ports 1 and 2 Assembly Model Code* 3/4” NPTF CXHA-X*N-IAD 1” NPTF CXHA-X*N-IAE 1 1/4” NPTF CXHA-X*N-IAF SAE-12 CXHA-X*N-IAL SAE-16 CXHA-X*N-IAM X Control .91 Max. 0 2 1.50 1 1.88 G 3.00 1.00 0 2.62 Assembly Model Code* 3/4” NPTF CXGD-X*N-IAD 1” NPTF CXGD-X*N-IAE 1 1/4” NPTF CXGD-X*N-IAF SAE-12 CXGD-X*N-IAL SAE-16 CXGD-X*N-IAM 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-160 GPM 2 Ports 1 and 2 Cavity T-18A 0-120 GPM 2 2.75 1.38 G G 0 1 Mounting Hole: .42 diameter through hole Ports 1 and 2 1 1/4” NPTF Gauge Port Assembly Model Code* 0 X Control 1.13 Max. 2 .62 Ports 1 and 2 Assembly Model Code* 3/4” NPTF CXJA-X*N-LAD 3/4” NPTF CXID-X*N-LAD 1” NPTF CXJA-X*N-LAE 1” NPTF CXID-X*N-LAE 1 1/4” NPTF CXJA-X*N-LAF SAE-12 CXJA-X*N-LAL SAE-16 CXJA-X*N-LAM 1 2.12 G 3.50 0 2.81 1.09 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4.62 1 1/4” NPTF CXID-X*N-LAF SAE-12 CXID-X*N-LAL SAE-16 CXID-X*N-LAM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 105 CHECK Line Mounted Assemblies TWO PORT FLOW CONTROL APPLICATIONS (INLINE BODIES) FREE FLOW Port 1 to Port 2 FREE FLOW Port 2 to Port 1 Go to www.sunhydraulics.com for more product information and pricing. 0-10 GPM Cavity T-162A 0-8 GPM 2 2 X Control .57 Max. 2.00 1 1 1.12 Ports 1 and 2 Assembly Model Code* 1/4” NPTF CXBA-X*N-ACA .56 3/8” NPTF CXBA-X*N-ACB SAE-4 CXBA-X*N-ACH .25 0 0 SAE-6 CXBA-X*N-ACI 1.00 .50 0 Ports 1 and 2 2 1 2.56 1.28 0 Assembly Model Code* 1/4” NPTF CXAD-X*N-ACA 3/8” NPTF CXAD-X*N-ACB SAE-4 CXAD-X*N-ACH SAE-6 CXAD-X*N-ACI Mounting Holes: .28 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-20 GPM Cavity T-13A 0-16 GPM 2 2 X Control .72 Max. 2.00 1 1 1.52 1.13 Ports 1 and 2 Assembly Model Code* 1/4” NPTF CXDA-X*N-GCA .56 3/8” NPTF CXDA-X*N-GCB .25 0 0 SAE-6 CXDA-X*N-GCI SAE-8 CXDA-X*N-GCJ 1.19 .59 0 Ports 1 and 2 2 1 0 1.28 2.56 Mounting Holes: .34 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Assembly Model Code* 1/4” NPTF CXCD-X*N-GCA 3/8” NPTF CXCD-X*N-GCB SAE-6 CXCD-X*N-GCI SAE-8 CXCD-X*N-GCJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-40 GPM Cavity T-5A 0-31 GPM 2 2 X Control .66 Max. 2.38 1.75 1 Ports 1 and 2 Assembly Model Code* 3/8” NPTF CXFA-X*N-DCB 1/2” NPTF CXFA-X*N-DCC SAE-6 CXFA-X*N-DCI SAE-8 CXFA-X*N-DCJ SAE-10 CXFA-X*N-DCK 1 1.25 Ports 1 and 2 2 .63 1 .31 0 0 1.50 .75 0 0 1.63 Mounting Holes: .42 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.25 Assembly Model Code* 3/8” NPTF CXED-X*N-DCB 1/2” NPTF CXED-X*N-DCC SAE-6 CXED-X*N-DCI SAE-8 CXED-X*N-DCJ SAE-10 CXED-X*N-DCK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 106 US Selected Assemblies Catalogue #999-901-192 Line Mounted Assemblies CHECK TWO PORT FLOW CONTROL APPLICATIONS (INLINE/INLINE 1.50”/2.00” SAE C61 FLANGE PORT BODIES) FREE FLOW Port 1 to Port 2 FREE FLOW Port 2 to Port 1 Go to www.sunhydraulics.com for more product information and pricing. 0-80 GPM Cavity T-16A 0-60 GPM 2 2 X Control .92 Max. 3.88 1 1 3.00 Ports 1 and 2 Assembly Model Code* 3/4” NPTF CXHA-X*N-ICD 1” NPTF CXHA-X*N-ICE 1 1/4” NPTF CXHA-X*N-ICF SAE-12 CXHA-X*N-ICL SAE-16 CXHA-X*N-ICM 2.31 Ports 1 and 2 1.16 1 2 .50 0 2.25 1.12 0 0 2.31 4.62 Mounting Holes: .53 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Assembly Model Code* 3/4” NPTF CXGD-X*N-ICD 1” NPTF CXGD-X*N-ICE 1 1/4” NPTF CXGD-X*N-ICF SAE-12 CXGD-X*N-ICL SAE-16 CXGD-X*N-ICM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-160 GPM Cavity T-18A 2 0-120 GPM 2 X Control .66 Max. 6.25 5.00 1 1 4.00 Ports 1 and 2 Assembly Model Code* 1 1/2” SAE C61 CXJA-X*N-ZLS 2 2.00 1.50 0 3.75 1.88 1 Ports 1 and 2 Assembly Model Code* 1 1/2” SAE C61 CXID-X*N-ZLS 0 0 0 2.50 5.00 Mounting Holes: .53 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-160 GPM Cavity T-18A 2 0-120 GPM 2 X Control .66 Max. 6.25 5.00 1 1 4.00 Ports 1 and 2 Assembly Model Code* 2” SAE C61 CXJA-X*N-ZLR 2 1 2.00 1.50 0 4.12 2.06 0 Ports 1 and 2 Assembly Model Code* 2” SAE C61 CXID-X*N-ZLR 0 0 2.50 5.00 Mounting Holes: .53 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 107 CHECK Line Mounted Assemblies TWO PORT FLOW CONTROL APPLICATIONS (2.00” SAE C61/C62 FLANGE PORT BODIES, 2 PORT CAVITY IN PARALLEL) FREE FLOW Port 1 to Port 2 FREE FLOW Port 2 to Port 1 Go to www.sunhydraulics.com for more product information and pricing. 0-320 GPM Cavity T-18A 0-240 GPM 4.94 2 2 2.47 1 1 0 Ports 1 and 2 Assembly Model Code* 2” SAE C61 CXJA-X*N-XZY Mounting Holes: .375-16 UNC-2B x .62 deep. 2 places. 0 X Control .91 Max. .94 Ports 1 and 2 Assembly Model Code* 2” SAE C61 CXID-X*N-XZY 2.47 4.00 4.94 0 2.03 4.66 6.56 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-320 GPM Cavity T-18A 0-240 GPM 5.94 2 2 2 2.97 1 1 0 Mounting Holes: .375-16 UNC x .75 deep. 2 places. Ports 1 and 2 Assembly Model Code* 2” SAE C62 CXJA-X*N-VTN 0 .63 Max. 1.06 Ports 1 and 2 Assembly Model Code* 2” SAE C62 CXID-X*N-VTN 1 2.97 X Control 4.88 5.94 0 2.28 4.88 7.12 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 108 US Selected Assemblies Catalogue #999-901-192 Needle Assemblies Cartridge Type Page 2 Fully Adjustable Needle 110 Fully Adjustable Needle with Reverse Free Flow Check 110 1 2 1 Line Mounted Assemblies (Body Type) 2 2 1 90 Degree 112 90 Degree with Gauge Port 113 Inline Inline/Inline 1.50”/2.00” SAE C61 Flange Port 2.00” SAE C61/C62 Flange Port, 2 Port Cavity in Parallel 114 115 116 1 2 G 1 2 1 US Selected Assemblies Catalogue #999-901-192 109 NEEDLE / RESTRICTOR Needle Valves FULLY ADJUSTABLE NEEDLE 2 Cartridge Dimensions c b L H Capacity Typical Cartridge Model Code .16 in NFBC – LCN T - 162A 1.22 3/4” 1.59 - 1.73 Installation Torque (lb. ft.) 25/30 .19 in NFCC – LCN T - 13A 1.38 7/8” 2.06 2.44 2.31 30/35 1 Cavity a K .25 in. NFDC – LAN T - 5A 1.38 1 1/8” 2.44 2.82 2.73 45/50 .38 in. NFEC – LEN T - 16A 1.81 1 1/4” 2.66 3.06 2.91 150/160 .56 in. NFFC – LGN T - 18A 2.50 1 5/8” 3.31 3.50 3.47 350/375 OPTION ORDERING INFORMATION NF ✱ C – ✱ ✱ ✱ Full Adjustment 5 Turns + Nominal Capacity c b Locating Shoulder Control** B .16 in. L Standard Screw C .19 in. D .25 in. H Calibrated Handknob with Detent Lock E .38 in. K Handknob F .56 in. Maximum Diameter Orifice C .16 in. C .19 in. D .10 in. A .25 in. B .13 in. a E .38 in. F .28 in. 2 Port ** See page 244 for information on Control Options Port 1 G .56 in. H .38 in. Seal N Buna-N NFBC V Viton NFCC NFDC NFEC NFFC FULLY ADJUSTABLE NEEDLE WITH REVERSE FREE FLOW CHECK 2 1 Capacity Typical Cartridge Model Code .16 NCBB – LCN Cartridge Dimensions c a b L H K T - 162A 1.22 3/4” 1.59 - 1.73 Installation Torque (lb. ft.) 25/30 30/35 Cavity .19 NCCB – LCN T - 13A 1.38 7/8” 2.06 2.44 2.31 .25 NCEB – LCN T - 5A 1.38 1 1/8” 2.44 2.82 2.73 45/50 .38 NCFB – LCN T - 16A 1.81 1 1/4” 2.66 3.06 2.91 150/160 .56 NCGB – LCN T - 18A 2.50 1 5/8” 3.31 3.50 3.47 350/375 OPTION ORDERING INFORMATION NC ✱ B – ✱ ✱ ✱ Full Adjustment 5 Turns + - Nominal Capacity c b Locating Shoulder Control** Cracking Pressure* Seal NCBB*0.16” dia. L Standard Screw A 4 psi N Buna-N NCCB 0.19” dia. NCCC.09” dia. H Calibrated Handknob wit Detent Lock C 30 psi V Viton NCEB.25” dia. NCEC.13” dia. E 75 psi K Handknob NCFB.38” dia. NCFC.28” dia. 2 Port Port 1 a NCGB.56” dia. NCGC.38” dia. ** See page 244 for information on Control Options 110 *Cracking Pressure Ranges: A and E ranges are not available in T-162A cavity US Selected Assemblies Catalogue #999-901-192 NEEDLE / RESTRICTOR TECHNICAL TIPS / PERFORMANCE CURVES Needle Valves, Fully Adjustable Performance Curves Adjustment Sensitivity at 100 psi Differential NFBC-L*N NFCC-L*N 7 Flow = GPM 5 Flow = GPM Applications These adjustable needle valves offer accurate and precise flow control because of their balanced adjustment design. They may be used for bidirectional operation. Design Concepts and Features ■ Sharp-edge orifice minimizes flow variation with viscosity changes. ■ Optional needle orifice ranges. See page 110. ■ Positive shut-off of flow when closed. 3.75 2.5 LCN 1.25 0 1 2 3 4 Number of Turns 5.25 3.5 1 2 3 4 5 Number of Turns NFEC-L*N 40 Flow = GPM 20 Flow = GPM LDN 0 5 NFDC-L*N LCN 1.75 15 10 LAN 5 LBN 0 1 2 3 4 Number of Turns 30 20 LEN LFN 10 0 5 1 2 3 4 Number of Turns 5 NFFC-L*N Flow = GPM 80 60 40 LGN LHN 20 0 1 2 3 4 Number of Turns 5 Needle Valves, Fully Adjustable with Reverse Free Flow Check B C P = psi 300 E F G 200 Adjustment Sensitivity at 100 psi Differential NCBB-L*N NCCB-L*N 6 Flow = GPM Flow = GPM 6 5 4 3 2 1 0 1 2 3 4 Number of Turns 5 4 3 2 1 0 5 NCEB-L*N 1 6 4 2 40 80 120 2 3 4 5 20 15 10 5 1 2 3 4 5 3 4 5 Number of Turns 0 1 Number of Turns 60 50 40 30 20 10 1 2 Number of Turns General Application Requirements ■ 5 25 NCGB-L*N Flow = GPM Flow = GPM 0 ■ 4 100 0 ■ 3 30 10 8 0 ■ 2 Number of Turns NCFB-L*N 12 Flow = GPM Reverse Flow Pressure Drop with Needle Closed Performance Curves Flow = GPM Applications These adjustable needle valves with integral reverse free flow check fit the same cavity as the needle valve without check. Design Concepts and Features ■ Performance parameters of the adjustable needle cartridge with check are similar to the NF*C. However, the leakage rate when closed is approximately 5 drops / min. or less. Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at a 4 GPM flow rate. US Selected Assemblies Catalogue #999-901-192 111 NEEDLE / RESTRICTOR Line Mounted Assemblies TWO PORT FLOW CONTROL APPLICATIONS (90 DEGREE BODIES) Go to www.sunhydraulics.com for more product information and pricing. FULLY ADJUSTABLE NEEDLE 0-.16 in. 2 FULLY ADJUSTABLE NEEDLE WITH REVERSE FREE FLOW CHECK Cavity T-162A 2 1.00 .50 1 Ports 1 and 2 1 0 Assembly Model Code* 1/4” NPTF NFBC-L*N-AAA 3/8” NPTF NFBC-L*N-AAB SAE-4 NFBC-L*N-AAH SAE-6 NFBC-L*N-AAI 0 .50 1.22 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 1.56 Max. 2 Assembly Model Code* 1/4” NPTF NCBB-L*N-AAA 3/8” NPTF NCBB-L*N-AAB SAE-4 NCBB-L*N-AAH SAE-6 NCBB-L*N-AAI 1 1.50 0 .28 1.33 0-.19 in. 2 Ports 1 and 2 Mounting Holes: .28 diameter through hole *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.00 Cavity T-13A 2 1.25 .62 1 1 Ports 1 and 2 0 Assembly Model Code* 1/4” NPTF NFCC-L*N-GAA 3/8” NPTF NFCC-L*N-GAB SAE-4 NFCC-L*N-GAH SAE-6 NFCC-L*N-GAI SAE-8 NFCC-L*N-GAJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Mounting Holes: .34 diameter through hole 0 .28 1.00 2 Assembly Model Code* 1/4” NPTF NCCB-L*N-GAA 3/8” NPTF NCCB-L*N-GAB SAE-4 NCCB-L*N-GAH 1 1.62 0 .28 1.44 0-.25 in. 2 L Control 2.03 Max. Ports 1 and 2 SAE-6 NCCB-L*N-GAI SAE-8 NCCB-L*N-GAJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.19 Cavity T-5A 2 1.50 .75 1 Ports 1 and 2 1 0 Assembly Model Code* 1/4” NPTF NFDC-L*N-DAA 3/8” NPTF NFDC-L*N-DAB 1/2” NPTF NFDC-L*N-DAC SAE-4 NFDC-L*N-DAI SAE-6 NFDC-L*N-DAJ SAE-8 NFDC-L*N-DAK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports 1 and 2 Mounting Holes: .42 diameter through hole 0 .38 1.25 L Control 2.38 Max. 2 1/4” NPTF NCEB-L*N-DAA 3/8” NPTF NCEB-L*N-DAB 1/2” NPTF NCEB-L*N-DAC 1 2.00 0 .38 1.69 2.62 Assembly Model Code* SAE-4 NCEB-L*N-DAI SAE-6 NCEB-L*N-DAJ SAE-8 NCEB-L*N-DAK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 112 US Selected Assemblies Catalogue #999-901-192 TWO PORT FLOW CONTROL APPLICATIONS (90 DEGREE BODIES) Go to www.sunhydraulics.com for more product information and pricing. FULLY ADJUSTABLE 0-.38 in. FULLY ADJUSTABLE WITH REVERSE FREE FLOW CHECK Cavity T-16A 2 2 2.25 G 1 1.12 G 1 0 1/4” NPTF Gauge Port Ports 1 and 2 Assembly Model Code* 3/4” NPTF NFEC-L*N-IAD 1” NPTF NFEC-L*N-IAE 1 1/4” NPTF NFEC-L*N-IAF SAE-12 NFEC-L*N-IAL SAE-16 NFEC-L*N-IAM Mounting Hole: .42 diameter through hole 0 L Control 2.60 Max. 2 .50 1 1.88 G Ports 1 and 2 Assembly Model Code* 3/4” NPTF NCFB-L*N-IAD 1” NPTF NCFB-L*N-IAE 1 1/4” NPTF NCFB-L*N-IAF SAE-12 NCFB-L*N-IAL SAE-16 NCFB-L*N-IAM 3.00 1.00 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.62 4.00 0-.56 in. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-18A 2 2 2.75 G 1 G 1.38 1 0 1/4” NPTF Gauge Port Ports 1 and 2 Assembly Model Code* 3/4” NPTF NFFC-L*N-LAD 1” NPTF NFFC-L*N-LAE 1 1/4” NPTF NFFC-L*N-LAF SAE-12 NFFC-L*N-LAL SAE-16 NFFC-L*N-LAM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Mounting Hole: .42 diameter through hole 0 L Control 3.25 Max. 2 .62 1 2.12 G 3.50 0 1.09 2.81 4.62 Ports 1 and 2 Assembly Model Code* 3/4” NPTF NCGB-L*N-LAD 1” NPTF NCGB-L*N-LAE 1 1/4” NPTF NCGB-L*N-LAF SAE-12 NCGB-L*N-LAL SAE-16 NCGB-L*N-LAM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 113 NEEDLE / RESTRICTOR Line Mounted Assemblies NEEDLE / RESTRICTOR Line Mounted Assemblies TWO PORT FLOW CONTROL APPLICATIONS (INLINE BODIES) 0-.16 in. 2 FULLY ADJUSTABLE NEEDLE WITH REVERSE FREE FLOW CHECK Go to www.sunhydraulics.com for more product information and pricing. FULLY ADJUSTABLEV NEEDLE Cavity T-162A 2 L Control 1.34 Max. 1 Ports 1 and 2 1 2.00 Assembly Model Code* 1/4” NPTF NFBC-L*N-ACA 3/8” NPTF NFBC-L*N-ACB SAE-4 NFBC-L*N-ACH SAE-6 NFBC-L*N-ACI Ports 1 and 2 1.12 .50 1/4” NPTF NCBB-L*N-ACA 3/8” NPTF NCBB-L*N-ACB SAE-4 NCBB-L*N-ACH SAE-6 NCBB-L*N-ACI .25 0 0 1.00 1 2 .56 0 2.56 1.28 Assembly Model Code* 0 Mounting Holes: .28 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-.19 in. 2 Cavity T-13A 2 L Control 2.03 Max. 1 1 2.00 Ports 1 and 2 Assembly Model Code* 1/4” NPTF NFCC-L*N-GCA 3/8” NPTF NFCC-L*N-GCB SAE-4 NFCC-L*N-GCH SAE-6 NFCC-L*N-GCI SAE-8 NFCC-L*N-GCJ 1.52 1.13 .59 0 0 1.28 1/4” NPTF NCCB-L*N-GCA 3/8” NPTF NCCB-L*N-GCB SAE-4 NCCB-L*N-GCH 2.56 Mounting Holes: .34 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. SAE-6 NCCB-L*N-GCI SAE-8 NCCB-L*N-GCJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-.25 in. 2 Assembly Model Code* .25 0 0 1.19 1 2 .56 Ports 1 and 2 Cavity T-5A 2 L Control 2.41 Max. 1 1 2.38 Ports 1 and 2 Assembly Model Code* 1.75 3/8” NPTF NFDC-L*N-DCB 1.25 3/8” NPTF NCEB-L*N-DCB 1/2” NPTF NFDC-L*N-DCC .63 1/2” NPTF NCEB-L*N-DCC SAE-6 NFDC-L*N-DCI SAE-8 NFDC-L*N-DCJ SAE-10 NFDC-L*N-DCK 0 1.50 .75 0 Ports 1 and 2 2 1 .31 0 0 1.63 Mounting Holes: .42 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Assembly Model Code* SAE-6 NCEB-L*N-DCI SAE-8 NCEB-L*N-DCJ SAE-10 NCEB-L*N-DCK 3.25 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 114 US Selected Assemblies Catalogue #999-901-192 TWO PORT FLOW CONTROL APPLICATIONS (INLINE/INLINE 1.50”/2.00” SAE C61 FLANGE PORT BODIES) 0-.38 in. 2 FULLY ADJUSTABLE NEEDLE WITH REVERSE FREE FLOW CHECK Go to www.sunhydraulics.com for more product information and pricing. FULLY ADJUSTABLE NEEDLE Cavity T-16A 2 L Control 2.61 Max. 1 1 3.88 Ports 1 and 2 Assembly Model Code* 3/4” NPTF NFEC-L*N-ICD 1” NPTF NFEC-L*N-ICE 1 1/4” NPTF NFEC-L*N-ICF SAE-12 NFEC-L*N-ICL SAE-16 NFEC-L*N-ICM Ports 1 and 2 3.00 2.31 1 2 1.16 .50 0 2.25 1.12 0 0 2.31 4.62 Assembly Model Code* 3/4” NPTF NCFB-L*N-ICD 1” NPTF NCFB-L*N-ICE 1 1/4” NPTF NCFB-L*N-ICF SAE-12 NCFB-L*N-ICL SAE-16 NCFB-L*N-ICM Mounting Holes: .53 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-.56 in. 2 Cavity T-18A 2 L Control 2.78 Max. 6.25 1 1 5.00 Ports 1 and 2 Assembly Model Code* 1 1/2” SAE C61 NFFC-L*N-ZLS 4.00 2 2.00 0 NCGB-L*N-ZLS 0 2.50 5.00 Mounting Holes: .53 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-.56 in. 2 1 1/2” SAE C61 0 0 1.88 Assembly Model Code* 1 1.50 3.75 Ports 1 and 2 Cavity T-18A 2 L Control 2.78 Max. 1 6.25 1 5.00 Ports 1 and 2 Assembly Model Code* 2” SAE C61 NFFC-L*N-ZLR 4.00 2.00 0 4.12 2.06 0 2 Ports 1 and 2 Assembly Model Code* 2” SAE C61 NCGB-L*N-ZLR 1 1.50 0 0 2.50 5.00 Mounting Holes: .53 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 115 NEEDLE / RESTRICTOR Line Mounted Assemblies NEEDLE / RESTRICTOR Line Mounted Assemblies TWO PORT FLOW CONTROL APPLICATIONS (2.00” SAE C61/C62 FLANGE PORT BODIES, 2 PORT CAVITY IN PARALLEL) Go to www.sunhydraulics.com for more product information and pricing. FULLY ADJUSTABLE NEEDLE 0-1.10 in. 2 FULLY ADJUSTABLE NEEDLE WITH REVERSE FREE FLOW CHECK Cavity T-18A 2 4.94 2.47 1 1 0 Ports 1 and 2 Assembly Model Code* 2” SAE C61 NFFC-L*N-XZY 0 Mounting Holes: .375-16 UNC-2B x .62 deep. 2 places. L Control 3.03 Max. .94 Ports 1 and 2 Assembly Model Code* 2” SAE C61 NCGB-L*N-XZY 2.47 4.00 4.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 2.03 4.66 0-1.10 in. 6.56 Cavity T-18A 2 2 5.94 2 2.97 1 1 0 Ports 1 and 2 Assembly Model Code* 2” SAE C62 NFFC-L*N-VTN Mounting Holes: .375-16 UNC x .75 deep. 2 places. 0 L Control 2.75 Max. 1.06 2.97 Ports 1 and 2 Assembly Model Code* 2” SAE C62 NCGB-L*N-VTN 1 4.88 5.94 0 2.28 4.88 7.12 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 116 US Selected Assemblies Catalogue #999-901-192 Fixed Orifice Pressure Compensated Flow Control Assemblies Cartridge Type Page 2 Fixed Orifice, Pressure Compensated 118 Fixed Orifice, Pressure Compensated with Free Flow Check 118 1 2 1 Line Mounted Assemblies (Body Type) 2 90 Degree 120 90 Degree with Gauge Port 121 Inline Inline/Inline 1.50”/2.00” SAE C61 Flange Port 2.00” SAE C61/ C62 Flange Port, 2 Port Cavity in Parallel 122 123 124 1 2 G 1 2 1 US Selected Assemblies Catalogue #999-901-192 117 FLOW CONTROL Flow Control Valves FIXED ORIFICE, PRESSURE COMPENSATED 2 1 Capacity Typical Cartridge Model Code Cavity Cartridge Dimensions c b X L .1-3 GPM FXBA – LAN T - 162A 1.22 3/4” .82 2.11 2.25 Installation Torque (lb. ft.) 25/30 .1-6.0 GPM FXCA – LAN T - 13A 1.38 7/8” .75 2.00 2.25 30/35 .1-12.0 GPM FXDA – LAN T - 5A 1.62 1 1/8” .69 2.12 2.38 45/50 .2-25 GPM FXEA – LAN T - 16A 2.44 1 1/4” .97 2.44 2.69 150/160 .2-50 GPM FXFA – LAN T - 18A 3.13 1 5/8” 1.19 2.81 3.06 350/375 a K OPTION ORDERING INFORMATION FX ✱ A – ✱ A ✱ Full Adjustment ± 3 Turns + Nominal Capacity L Control Control** B .1-3 GPM X Control c b Adjustment Range X Non-adjustable Factory set at customer specified flow C .1-6.0 GPM D .1-12.0 GPM Locating Shoulder E .2-25 GPM A Fixed Orifice Seal N Buna-N Customer must specify flow V Viton L Tuning Adjustment ±25% of customer specified flow F .2-50 GPM K Handknob for L control a 2 Port ** See page 244 for information on Control Options Port 1 Flow Ranges by Frame Size: FXBA: .1 - 3 GPM FXCA: .1 - 6.0 GPM FXDA: .1 - 12.0 GPM FXEA: .2 - 25 GPM FXFA: .2 - 50 GPM FIXED ORIFICE, PRESSURE COMPENSATED WITH FREE FLOW CHECK 2 1 Capacity Typical Cartridge Model Code Cavity a .1-3 GPM FCBB – LAN T - 162A 1.22 Cartridge Dimensions c b X L 3/4” .82 2.11 K 2.55 Installation Torque (lb. ft.) 25/30 .1-6.0 GPM FCCB – LAN T - 13A 1.38 7/8” .75 2.00 2.25 30/35 .1-12.0 GPM FCDB – LAN T - 5A 1.62 1 1/8” .69 2.12 2.38 45/50 .2-25 GPM FCEB – LAN T - 16A 2.44 1 1/4” .97 2.44 2.69 150/160 .2-50 GPM FCFB – LAN T - 18A 3.13 1 5/8” 1.19 2.81 3.06 350/375 OPTION ORDERING INFORMATION FC ✱ B – ✱ A ✱ Full Adjustment ± 3 Turns + Nominal Capacity L Control X Control B .1-3 GPM c b C .1-6.0 GPM D .1-12.0 GPM Locating Shoulder E .2-25 GPM F .2-50 GPM a Control** X Non-adjustable Factory set at customer specified flow A Fixed Orifice Seal N Buna-N Customer must specify flow V Viton L Tuning Adjustment ±25% of customer specified flow K Handknob for L control 2 Port Port 1 Adjustment Range ** See page 244 for information on Control Options 118 Flow Ranges by Frame Size: FCBB: .1 - 3 GPM FCCB: .1 - 6.0 GPM FCDB: .1 - 12.0 GPM FCEB: .2 - 25 GPM FCFB: .2 - 50 GPM US Selected Assemblies Catalogue #999-901-192 TECHNICAL TIPS / PERFORMANCE CURVES FXCA-*A* 8 Flow = GPM 3 2.25 1.5 0.75 0 6 4 2 1000 2000 3000 4000 5000 FXDA-*A* P= psi 0 1000 2000 3000 4000 5000 P = psi FXEA-*A* 32 15 Flow = GPM Design Concepts and Features ■ Minimum flow change over widely varying load pressure changes (less than ± 5% over 4500 psi load change). ■ Selectable fixed orifice size (flow capacity 0.1 to 50 GPM, dependent on frame size). ■ Tunable control option to provide ± 25% variation of the nominal factory set flow. Typical Performance FXBA-*A* Flow = GPM NOTE: Accurate pressure-compensated control requires a 195 psi minimum pressure differential be maintained across the valve Performance Curves Flow = GPM Applications These pressure-compensated cartridges provide precise flow regulation for meter-in and meter-out applications. They also offer accurate control in bleedoff circuits where the load pressure and inlet flow are relatively constant. FLOW CONTROL Flow Control Valves, Fixed Orifice, Pressure Compensated 12.25 7.5 3.75 0 24 16 8 0 1000 2000 3000 4000 5000 FXFA-*A* 1000 2000 3000 4000 5000 P = psi P = psi Flow = GPM 60 45 30 15 0 1000 2000 3000 4000 5000 P = psi Flow Control Valves, Fixed Orifice, Pressure Compensated with Free Flow Check Reverse Free Flow Pressure Drop FCBB-*A* FCCB-*A* 300 300 P = psi Note: Accurate pressure-compensated control requires a 195 psi minimum pressure differential be maintained across the valve Performance Curves P = psi Applications The performance parameters of the FC*B pressure compensated flow control with free flow check are identical to the FX*A, but with the addition of a high capacity free flow check. 200 .1 GPM 100 3 GPM 200 .1 GPM 100 6 GPM 0 2 4 6 8 0 10 2 4 FCDB-*A* P = psi P = psi 100 .1 GPM 50 0 .2 GPM 50 4 8 12 Flow = GPM 16 25 GPM 20 0 8 P = psi 200 135 .2 GPM 65 50 GPM 0 16 32 48 64 80 Flow = GPM General Application Requirements ■ Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at a 4 GPM flow rate. US Selected Assemblies Catalogue #999-901-192 119 40 100 FCFB-*A* ■ 32 150 12 GPM ■ 10 FCEB-*A* 150 ■ 8 6 Flow = GPM Flow = GPM 16 24 Flow = GPM FLOW CONTROL Line Mounted Assemblies TWO PORT FLOW CONTROL APPLICATIONS (90 DEGREE BODIES) Go to www.sunhydraulics.com for more product information and pricing. FIXED ORIFICE .1-3 GPM FIXED ORIFICE WITH REVERSE FREE FLOW CHECK Cavity T-162A 2 2 1.00 .50 1 0 1 Mounting Holes: .28 diameter through hole Ports 1 and 2 Assembly Model Code* 1/4” NPTF FXBA-LAN-AAA 0 3/8” NPTF FXBA-LAN-AAB .50 SAE-4 FXBA-LAN-AAH SAE-6 FXBA-LAN-AAI Ports 1 and 2 L Control 2.08 Max. 2 1 1.22 Assembly Model Code* 1/4” NPTF FCBB-LAN-AAA 3/8” NPTF FCBB-LAN-AAB SAE-4 FCBB-LAN-AAH SAE-6 FCBB-LAN-AAI 1.50 0 .28 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.33 .1-6.0 GPM 2 2.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-13A 2 1.25 .62 1 Ports 1 and 2 1 0 Assembly Model Code* Ports 1 and 2 Mounting Holes: .34 diameter through hole 1/4” NPTF FXCA-LAN-GAA 0 3/8” NPTF FXCA-LAN-GAB .28 SAE-4 FXCA-LAN-GAH SAE-6 FXCA-LAN-GAI SAE-8 FXCA-LAN-GAJ 1.00 L Control 1.97 Max. 2 1 Assembly Model Code* 1/4” NPTF FCCB-LAN-GAA 3/8” NPTF FCCB-LAN-GAB SAE-4 FCCB-LAN-GAH SAE-6 FCCB-LAN-GAI SAE-8 FCCB-LAN-GAJ 1.62 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .28 1.44 .1-12.0 GPM 2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.19 Cavity T-5A 2 1.50 .75 1 Ports 1 and 2 1 0 Assembly Model Code* 1/4” NPTF FXDA-LAN-DAA 0 3/8” NPTF FXDA-LAN-DAB .38 1/2” NPTF FXDA-LAN-DAC SAE-4 FXDA-LAN-DAI SAE-6 FXDA-LAN-DAJ SAE-8 FXDA-LAN-DAK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports 1 and 2 Mounting Holes: .42 diameter through hole 1.25 L Control 2.06 Max. 2 1 2.00 0 .38 1.69 2.62 Assembly Model Code* 1/4” NPTF FCDB-LAN-DAA 3/8” NPTF FCDB-LAN-DAB 1/2” NPTF FCDB-LAN-DAC SAE-4 FCDB-LAN-DAI SAE-6 FCDB-LAN-DAJ SAE-8 FCDB-LAN-DAK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 118 for cartridge models FX*A-*** and FC*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 120 US Selected Assemblies Catalogue #999-901-192 TWO PORT FLOW CONTROL APPLICATIONS (90 DEGREE BODIES) Go to www.sunhydraulics.com for more product information and pricing. FIXED ORIFICE .2-25 GPM FIXED ORIFICE WITH REVERSE FREE FLOW CHECK Cavity T-16A 2 2 2.25 G 1 1.12 G 1 0 1/4” NPTF Gauge Port Ports 1 and 2 Assembly Model Code* 3/4” NPTF FXEA-LAN-IAD 1” NPTF FXEA-LAN-IAE 1 1/4” NPTF FXEA-LAN-IAF SAE-12 FXEA-LAN-IAL SAE-16 FXEA-LAN-IAM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Mounting Hole: .42 diameter through hole 0 L Control 2.38 Max. 2 .50 1 1.88 G 3.00 1.00 0 2.62 .2-50 GPM 4.00 Ports 1 and 2 Assembly Model Code* 3/4” NPTF FCEB-LAN-IAD 1” NPTF FCEB-LAN-IAE 1 1/4” NPTF FCEB-LAN-IAF SAE-12 FCEB-LAN-IAL SAE-16 FCEB-LAN-IAM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Cavity T-18A 2 2 2.75 G 1 1.38 G 1 0 1/4” NPTF Gauge Port Ports 1 and 2 Assembly Model Code* 3/4” NPTF FXFA-LAN-LAD 1” NPTF FXFA-LAN-LAE 1 1/4” NPTF FXFA-LAN-LAF SAE-12 FXFA-LAN-LAL SAE-16 FXFA-LAN-LAM Mounting Hole: .42 diameter through hole 0 L Control 2.75 Max. 2 .62 1 2.12 G 3.50 0 1.09 2.81 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports 1 and 2 3/4” NPTF FCFB-LAN-LAD 1” NPTF FCFB-LAN-LAE 1 1/4” NPTF FCFB-LAN-LAF SAE-12 FCFB-LAN-LAL SAE-16 FCFB-LAN-LAM 4.62 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 118 for cartridge models FX*A-*** and FC*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 Assembly Model Code* 121 FLOW CONTROL Line Mounted Assemblies FLOW CONTROL Line Mounted Assemblies TWO PORT FLOW CONTROL APPLICATIONS (INLINE BODIES) .1-3 GPM 2 FIXED ORIFICE WITH REVERSE FREE FLOW CHECK Go to www.sunhydraulics.com for more product information and pricing. FIXED ORIFICE Cavity T-162A 2 L Control 1.86 Max. 1 1 2.00 Ports 1 and 2 Assembly Model Code* 1/4” NPTF FXBA-LAN-ACA 3/8” NPTF FXBA-LAN-ACB SAE-4 FXBA-LAN-ACH SAE-6 FXBA-LAN-ACI Ports 1 and 2 1.12 2 .56 1/4” NPTF FCBB-LAN-ACA 3/8” NPTF FCBB-LAN-ACB SAE-4 FCBB-LAN-ACH SAE-6 FCBB-LAN-ACI .25 0 0 1.00 .50 1 0 2.56 1.28 Assembly Model Code* 0 Mounting Holes: .28 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .1-6.0 GPM 2 Cavity T-13A 2 L Control 1.97 Max. 1 1 2.00 Ports 1 and 2 Assembly Model Code* 1/4” NPTF FXCA-LAN-GCA 3/8” NPTF FXCA-LAN-GCB SAE-4 FXCA-LAN-GCH SAE-6 FXCA-LAN-GCI SAE-8 FXCA-LAN-GCJ Ports 1 and 2 1.52 1.13 .59 0 0 1.28 FCCB-LAN-GCA FCCB-LAN-GCB SAE-4 FCCB-LAN-GCH 2.56 Mounting Holes: .34 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. SAE-6 FCCB-LAN-GCI SAE-8 FCCB-LAN-GCJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .1-12.0 GPM 2 1/4” NPTF 3/8” NPTF .25 0 0 1.19 1 2 .56 Assembly Model Code* Cavity T-5A 2 L Control 2.09 Max. 1 1 2.38 Ports 1 and 2 Assembly Model Code* Ports 1 and 2 1.75 1.25 3/8” NPTF FXDA-LAN-DCB 1/2” NPTF FXDA-LAN-DCC .63 SAE-6 FXDA-LAN-DCI 0 SAE-8 FXDA-LAN-DCJ SAE-10 FXDA-LAN-DCK 1.50 .75 0 2 1 .31 0 0 1.63 Mounting Holes: .42 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Assembly Model Code* 3/8” NPTF FCDB-LAN-DCB 1/2” NPTF FCDB-LAN-DCC SAE-6 FCDB-LAN-DCI SAE-8 FCDB-LAN-DCJ SAE-10 FCDB-LAN-DCK 3.25 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 118 for cartridge models FX*A-*** and FC*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 122 US Selected Assemblies Catalogue #999-901-192 TWO PORT FLOW CONTROL APPLICATIONS (INLINE/INLINE 1.50”/2.00” SAE C61 FLANGE PORT BODIES) .2-25 GPM 2 FIXED ORIFICE WITH REVERSE FREE FLOW CHECK Go to www.sunhydraulics.com for more product information and pricing. FIXED ORIFICE Cavity T-16A 2 L Control 2.39 Max. 1 1 3.88 Ports 1 and 2 Assembly Model Code* 3/4” NPTF FXEA-LAN-ICD 1” NPTF FXEA-LAN-ICE 1 1/4” NPTF FXEA-LAN-ICF SAE-12 FXEA-LAN-ICL SAE-16 FXEA-LAN-ICM 3.00 Ports 1 and 2 2.31 1 2 1.16 .50 0 2.25 1.12 0 0 2.31 4.62 Mounting Holes: .53 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3/4” NPTF FCEB-LAN-ICD 1” NPTF FCEB-LAN-ICE 1 1/4” NPTF FCEB-LAN-ICF SAE-12 FCEB-LAN-ICL SAE-16 FCEB-LAN-ICM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .2-50 GPM 2 Assembly Model Code* Cavity T-18A 2 L Control 2.28 Max. 6.25 1 1 5.00 Ports 1 and 2 Assembly Model Code* 1 1/2” SAE C61 FXFA-LAN-ZLS 4.00 2 2.00 1 1/2” SAE C61 FCFB-LAN-ZLS 0 0 1.88 Assembly Model Code* 1 1.50 3.75 Ports 1 and 2 0 0 2.50 5.00 Mounting Holes: .53 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .2-50 GPM 2 Cavity T-18A 2 L Control 2.28 Max. 6.25 1 1 5.00 Ports 1 and 2 Assembly Model Code* 2” SAE C61 FXFA-LAN-ZLR 4.00 2 2.00 1 1.50 0 4.12 2.06 0 Ports 1 and 2 Assembly Model Code* 2” SAE C61 FCFB-LAN-ZLR 0 0 2.50 5.00 Mounting Holes: .53 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 118 for cartridge models FX*A-*** and FC*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 123 FLOW CONTROL Line Mounted Assemblies FLOW CONTROL Line Mounted Assemblies TWO PORT FLOW CONTROL APPLICATIONS (2.00” SAE C61/C62 FLANGE PORT BODIES, 2 PORT CAVITY IN PARALLEL) FIXED ORIFICE Go to www.sunhydraulics.com for more product information and pricing. .2-100 GPM 2 Cavity T-18A 2 4.94 2.47 1 1 0 Ports 1 and 2 Assembly Model Code* 2” SAE C61 FXFA-LAN-XZY Mounting Holes: .375-16 UNC-2B x .62 deep. 2 places. 0 L Control 2.53 Max. .94 Ports 1 and 2 Assembly Model Code* 2” SAE C61 FCFB-LAN-XZY 2.47 4.00 4.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 2.03 4.66 .2-100 GPM 6.56 Cavity T-18A 2 5.94 2 2.97 1 0 Ports 1 and 2 Assembly Model Code* 2” SAE C62 FXFA-LAN-VTN Mounting Holes: .375-16 UNC x .75 deep. 2 places. 0 L Control 2.25 Max. 1.06 1 2.97 4.88 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 2.28 4.88 7.12 NOTES: Page 118 for cartridge models FX*A-*** and FC*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 124 US Selected Assemblies Catalogue #999-901-192 Fully Adjustable Pressure Compensated Flow Control Assemblies Cartridge Type Page 2 Fully Adjustable Pressure Compensated with Free Flow Check 126 1 Line Mounted Assemblies (Body Type) 2 90 Degree 128 90 Degree with Gauge Port 129 Inline Inline/Inline 1.50”/2.00” SAE C61 Flange Port 2.00” SAE C61/C62 Flange Port, 2 Port Cavities 130 131 132 1 2 G 1 2 1 US Selected Assemblies Catalogue #999-901-192 125 FLOW CONTROL Flow Control Valves FULLY ADJUSTABLE PRESSURE COMPENSATED WITH FREE FLOW CHECK Full Adjustment 5 Turns + 2 c b 1 Locating Shoulder a 2 Port Port 1 Capacity Typical Cartridge Model Code Cavity a Cartridge Dimensions c b L H K Installation Torque (lb. ft.) 30/35 .1-6 GPM FDBA – LAN T - 13A 1.38 7/8” 2.27 2.44 .1-12 GPM FDCB – LAN T - 5A 1.62 1 1/8” 2.35 2.82 2.73 45/50 .2-25 GPM FDEA – LAN T - 16A 2.44 1 1/4” 2.66 3.06 2.91 150/160 .2-50 GPM FDFA – LAN T - 18A 3.13 1 5/8” 3.31 3.50 3.47 350/375 2.31 OPTION ORDERING INFORMATION FD ✱ ✱ Nominal Capacity – Control** BA .1-6 GPM L Standard Screw CB .1-12 GPM H Calibrated Handknob with Detent Lock EA .2-25 GPM FA .2-50 GPM ✱A✱ K Adjustment Range FDBA A .1 - 6 GPM Seal N Buna-N V Viton FDCB A .1 - 12 GPM Handknob FDEA A .1 - 25 GPM FDFA A .1 - 50 GPM ** See page 244 for information on Control Options 126 US Selected Assemblies Catalogue #999-901-192 Flow Control Valves, Fully Adjustable, Pressure Compensated with Free Flow Check Performance Curves Reverse Free Flow with Needle Closed Typical Performance FDBA-LAN 10 Flow = GPM P = psi 300 200 100 0 2 4 6 Flow = GPM 8 10 8 6 4 2 0 1000 2000 3000 4000 5000 P = psi FDCB-LAN 15 Flow = GPM P = psi 300 200 100 0 4 8 12 Flow = GPM 16 12 9 6 3 20 0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000 P = psi FDEA-LAN 30 Flow = GPM 300 P = psi Applications The fully adjustable pressure compensated flow control (FD** series) is similar in function to the (FC*B) fixed orifice model with check. However, the FD** series offers full adjustment over the entire flow range of the cartridge. Design Concepts and Features ■ Sharp edge orifice design to minimize flow variation with viscosity change. ■ Five turns of adjustment with low operating effort at high pressure. ■ Optional needle ranges to provide different flow capacity. See page 110. ■ Leakage at shutoff: FDBA and FDCB 0.08 GPM FDEA and FDFA 0.1 GPM ■ Optional adjustment control options are as follows: – Standard screw adjustment – Handknob with locking ring – Calibrated handknob with detent lock 200 100 0 10 20 30 40 24 18 12 6 50 Flow = GPM P = psi FDFA-LAN 60 Flow = GPM P = psi 300 200 100 0 20 40 60 Flow = GPM 80 100 48 36 24 12 General Application Requirements ■ ■ ■ ■ Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. Factory Pressure Setting for cartridge is established at a 4 GPM flow rate. US Selected Assemblies Catalogue #999-901-192 127 P = psi FLOW CONTROL TECHNICAL TIPS / PERFORMANCE CURVES FLOW CONTROL Line Mounted Assemblies TWO PORT FLOW CONTROL APPLICATIONS (90 DEGREE BODIES) FULLY ADJUSTABLE WITH REVERSE FREE FLOW CHECK Go to www.sunhydraulics.com for more product information and pricing. .1-6.0 GPM 2 Cavity T-13A 1.25 .62 1 0 Ports 1 and 2 Assembly Model Code* 1/4” NPTF FDBA-LAN-GAA 0 3/8” NPTF FDBA-LAN-GAB .28 SAE-4 FDBA-LAN-GAH SAE-6 FDBA-LAN-GAI SAE-8 FDBA-LAN-GAJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Mounting Holes: .34 diameter through hole L Control 2.03 Max. 2 1.00 1 1.62 0 .28 1.44 .1-12.0 GPM 2 2.19 Cavity T-5A 1.50 .75 1 0 Ports 1 and 2 Assembly Model Code* 1/4” NPTF FDCB-LAN-DAA 0 3/8” NPTF FDCB-LAN-DAB .38 1/2” NPTF FDCB-LAN-DAC SAE-6 FDCB-LAN-DAI SAE-8 FDCB-LAN-DAJ SAE-10 FDCB-LAN-DAK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Mounting Holes: .42 diameter through hole L Control 2.38 Max. 2 1 1.25 2.00 0 .38 1.69 .0-12.0 GPM 2 2.62 Cavity T-5A 2.12 0 0 1 Ports 1 and 2 Assembly Model Code* 3/4 NPTF FDCB-LAN-DAD .75 0 .50 0 2 .50 1.50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Mounting Holes: .42 diameter through hole 3.00 L Control 2.38 Max 1 2.25 NOTES: Page 126 for cartridge model FD**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 128 US Selected Assemblies Catalogue #999-901-192 TWO PORT FLOW CONTROL APPLICATIONS (90 DEGREE BODIES) FULLY ADJUSTABLE WITH REVERSE FREE FLOW CHECK Go to www.sunhydraulics.com for more product information and pricing. .2-25 GPM 2 Cavity T-16A 2.25 G 1 1.12 0 Ports 1 and 2 Assembly Model Code* 3/4” NPTF FDEA-LAN-IAD 1” NPTF FDEA-LAN-IAE 1 1/4” NPTF FDEA-LAN-IAF SAE-12 FDEA-LAN-IAL SAE-16 FDEA-LAN-IAM 1/4” NPTF Gauge Port Mounting Hole: .42 diameter through hole 0 L Control 2.60 Max. 2 1.50 1 1.88 G *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.00 1.00 0 2.62 4.00 .2-50 GPM 2 Cavity T-18A 2.75 G 1 1.38 0 1/4” NPTF Gauge Port Ports 1 and 2 Assembly Model Code* 3/4” NPTF FDFA-LAN-LAD 0 1” NPTF FDFA-LAN-LAE .62 1 1/4” NPTF FDFA-LAN-LAF SAE-12 FDFA-LAN-LAL SAE-16 FDFA-LAN-LAM Mounting Hole: .42 diameter through hole L Control 3.25 Max. 2 1 2.12 G 3.50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 1.09 2.81 4.62 NOTES: Page 126 for cartridge model FD**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 129 FLOW CONTROL Line Mounted Assemblies FLOW CONTROL Line Mounted Assemblies TWO PORT FLOW CONTROL APPLICATIONS (INLINE BODIES) FULLY ADJUSTABLE WITH REVERSE FREE FLOW CHECK Go to www.sunhydraulics.com for more product information and pricing. .1-6.0 GPM 2 Cavity T-13A L Control 2.03 Max. 1 Ports 1 and 2 Assembly Model Code* 1/4” NPTF FDBA-LAN-GCA 3/8” NPTF FDBA-LAN-GCB SAE-4 FDBA-LAN-GCH SAE-6 FDBA-LAN-GCI SAE-8 FDBA-LAN-GCJ 2.00 1.52 1.13 .25 0 0 1.19 .59 1 2 .56 0 0 1.28 2.56 Mounting Holes: .34 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .1-12.0 GPM 2 Cavity T-5A L Control 2.41 Max. 1 2.38 1.75 Ports 1 and 2 Assembly Model Code* 3/8” NPTF FDCB-LAN-DCB 1/2” NPTF FDCB-LAN-DCC .63 SAE-6 FDCB-LAN-DCI 0 SAE-8 FDCB-LAN-DCJ SAE-10 FDCB-LAN-DCK 1.25 1.50 .75 0 2 1 .31 0 0 1.63 3.25 Mounting Holes: .42 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 126 for cartridge model FD**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 130 US Selected Assemblies Catalogue #999-901-192 TWO PORT FLOW CONTROL APPLICATIONS (INLINE/INLINE 1.50”/2.00” SAE C61 FLANGE PORT BODIES) FULLY ADJUSTABLE WITH REVERSE FREE FLOW CHECK Go to www.sunhydraulics.com for more product information and pricing. .2-25 GPM 2 Cavity T-16A L Control 2.13 Max. 1 Ports 1 and 2 Assembly Model Code* 3/4” NPTF FDEA-LAN-ICD 1” NPTF FDEA-LAN-ICE 1 1/4” NPTF FDEA-LAN-ICF SAE-12 FDEA-LAN-ICL SAE-16 FDEA-LAN-ICM 3.88 3.00 2.31 1 2 1.16 .50 0 2.25 1.12 0 0 2.31 4.62 Mounting Holes: .53 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .2-50 GPM 2 Cavity T-18A L Control 2.78 Max. 6.25 1 5.00 Ports 1 and 2 Assembly Model Code* 1 1/2” SAE C61 FDFA-LAN-ZLS 4.00 2 2.00 1 1.50 0 0 3.75 1.88 0 0 2.50 5.00 Mounting Holes: .53 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .2-50 GPM 2 Cavity T-18A L Control 2.78 Max. 6.25 1 5.00 Ports 1 and 2 Assembly Model Code* 2” SAE C61 FDFA-LAN-ZLR 4.00 2 2.00 1 1.50 0 4.12 2.06 0 0 0 2.50 5.00 Mounting Holes: .53 diameter through hole. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 126 for cartridge model FD**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 131 FLOW CONTROL Line Mounted Assemblies FLOW CONTROL Line Mounted Assemblies TWO PORT FLOW CONTROL APPLICATIONS (2.00” SAE C61/C62 FLANGE PORT BODIES, 2 CAVITIES) FULLY ADJUSTABLE WITH REVERSE FREE FLOW CHECK Go to www.sunhydraulics.com for more product information and pricing. .5-105 GPM 2 Cavity T-18A 4.94 2.47 1 0 Ports 1 and 2 Assembly Model Code* 2” SAE C61 FDFA-LAN-XZY 0 Mounting Holes: .375-16 UNC-2B x .62 deep. 2 places. L Control 3.03 Max. .94 2.47 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 4.94 0 2.03 4.66 .5-105 GPM 6.56 Cavity T-18A 2 5.94 2 2.97 1 0 Ports 1 and 2 Assembly Model Code* 2” SAE C62 FDFA-LAN-VTN Mounting Holes: .375-16 UNC x .75 deep. 2 places. 0 L Control 3.23 Max. 1.06 1 2.97 4.88 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 2.28 4.88 7.12 NOTES: Page 126 for cartridge models model FD**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 132 US Selected Assemblies Catalogue #999-901-192 Fixed Orifice Priority Flow Control Assemblies Cartridge Type Page 3 2 Bypass/Restrictive, Fixed Orifice 134 1 Line Mounted Assemblies (Body Type) 3 2 90 Degree High Capacity Port 3 136 90 Degree High Capacity with Gauge Port 137 Relief on Controlled Port 138 1 3 2 G 1 G CF EF T P US Selected Assemblies Catalogue #999-901-192 133 PRIORITY FLOW CONTROL Priority Flow Control Valves BYPASS / RESTRICTIVE, FIXED ORIFICE 3 2 1 Capacity Typical Cartridge Model Code Cavity Cartridge Dimensions c b X L .1-3 GPM FRBA – LAN T - 163A 1.22 3/4” 1.25 2.55 2.77 Installation Torque (lb. ft.) 25/30 .1-6.0 GPM FRCA – LAN T - 11A 1.38 7/8” 1.19 2.50 2.75 30/35 .1-12.0 GPM FRDA – LAN T - 2A 1.38 1 1/8” 1.38 2.81 3.06 45/50 .2-25 GPM FREA – LAN T - 17A 1.81 1 1/4” 1.81 3.28 3.53 150/160 .2-50 GPM FRFA – LAN T - 19A 2.50 1 5/8” 2.75 3.94 4.19 350/375 a K OPTION ORDERING INFORMATION FR ✱ A – ✱ A ✱ Full Adjustment ± 3 Turns + - Nominal Capacity L Control B .1-3 GPM X Control C .1-6.0 GPM c b D .1-12.0 GPM E .2-25 GPM 3 Priority Flow Locating Shoulder 2 Bypass Flow Inlet 1 a F .2-50 GPM Maximum Inlet Flow: FRBA: 7.5 GPM FRCA: 15 GPM FRDA: 30 GPM FREA: 60 GPM FRFA: 120 GPM Control** X Non-adjustable Factory set at customer specified flow Adjustment Range A Fixed Orifice Seal N Buna-N Customer must specify flow V Viton L Tuning Adjustment ±25% of customer specified flow K Handknob for L control ** See page 244 for information on Control Options 134 Priority Flow ranges: FRBA: .1 - 3 GPM FRCA: .1 - 6.0 GPM FRDA: .1 - 12.0 GPM FREA: .2 - 25 GPM FRFA: .2 - 50 GPM US Selected Assemblies Catalogue #999-901-192 TECHNICAL TIPS / PERFORMANCE CURVES Applications These combination priority and bypass flow control valves may be used to establish the flow to the priority or controlled flow circuit, and either bypass the remaining flow to tank at the load induced pressure of the system or use it in a secondary system. Application Notes ■ Valve will not bypass unless priority flow is satisfied. ■ Bypass pressure may exceed priority pressure. ■ Blocking the controlled flow path will also block the bypass flow path. ■ Note factory set point conditions. Design Concepts and Features ■ Customer specified, fixed orifice for priority flow. (Flow setting accuracy ± 10%.) ■ Tunable control option to provide ± 25% variation of the customer specified flow at factory preset conditions. Performance Curves Note: Tunable adjustment range follows performance curve profile. FRDA-LAN PRIORITY FLOW CONTROL Priority Flow Control Valves, Fixed Orifice, Bypass / Restrictive Typical Performance Priorty Flow GPM 5 Priorty Flow GPM FRBA-LAN 5 Factory Set Point with 8 GPM inlet (max.) with 6 GPM inlet with 4 GPM inlet 4 3 2 Valve Set @ 3 GPM with 8 GPM inlet (max.) 1 with 4 GPM inlet Valve Set @ 1 GPM 0 5000 3000 1000 0 1000 3000 5000 Bypass pressure P = psi Priority pressure higher than priority higher than bypass FRCA-LAN Factory Set Point with 15 GPM inlet (max.) with 10 GPM inlet with 5 GPM inlet 4 3 2 Valve Set @ 3 GPM with 15 GPM inlet (max.) with 5 GPM inlet Valve Set @ 1 GPM 0 5000 3000 1000 0 1000 3000 5000 Bypass pressure P = psi Priority pressure higher than priority higher than bypass 1 Priorty Flow GPM Factory Set Point 10 with 30 GPM inlet (max.) with 20 GPM inlet with 10 GPM inlet 8 6 Valve Set @ 6 GPM 4 2 with 30 GPM inlet (max.) with 10 GPM inlet Valve Set @ 2 GPM 0 5000 3000 1000 0 1000 3000 5000 Bypass pressure P = psi Priority pressure higher than priority higher than bypass FREA-LAN Factory Set Point Priorty Flow GPM 20 FRFA-LAN with 60 GPM inlet (max.) with 40 GPM inlet with 20 GPM inlet 16 12 Valve Set @ 12 GPM 8 4 with 60 GPM inlet (max.) with 20 GPM inlet Valve Set @ 4 GPM 0 5000 3000 1000 0 1000 3000 5000 Bypass pressure P = psi Priority pressure higher than priority higher than bypass Priorty Flow GPM Factory Set Point 50 40 30 Valve Set @ 30 GPM with 120 GPM inlet (max.) with 80 GPM inlet with 40 GPM inlet 20 with 120 GPM inlet (max.) with 40 GPM inlet Valve Set @ 10 GPM 0 5000 3000 10000 1000 3000 5000 Bypass pressure P = psi Priority pressure higher than priority higher than bypass 10 General Application Requirements ■ ■ ■ Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F. Viscosity Range: 60-3000 SUS. Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems. US Selected Assemblies Catalogue #999-901-192 135 PRIORITY FLOW CONTROL Line Mounted Assemblies THREE PORT PRIORITY FLOW CONTROL APPLICATIONS (90 DEGREE HIGH CAPACITY PORT 3 BODIES) BYPASS / RESTRICTIVE FIXED ORIFICE Go to www.sunhydraulics.com for more product information and pricing. .1-3 GPM Cavity T-163A 3 2 1.00 .50 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 1/4” NPTF 1/4” NPTF FRBA-LAN-JCA 3/8” NPTF 1/4” NPTF FRBA-LAN-JCB SAE-4 SAE-4 FRBA-LAN-JCH SAE-6 SAE-4 FRBA-LAN-JCI Mounting Holes: .28 diameter through hole 2 places. 0 .28 L Control 1.91 Max. 2 1 .97 3 2.00 1.31 0 2.14 2.59 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .1-6.0 GPM 3 2 Cavity T-11A 1.25 .62 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 3/8” NPTF FRCA-LAN-EAB 1/2” NPTF 3/8” NPTF FRCA-LAN-EAC SAE-8 SAE-8 FRCA-LAN-EAJ SAE-10 SAE-8 FRCA-LAN-EAK Mounting Holes: .34 diameter through hole, 2 places. 0 .38 L Control 1.81 Max. 2 1 1.25 3 2.50 .44 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.56 2.44 3.00 .1-12.0 GPM 3 2 Cavity T-2A 1.50 .75 1 0 Ports 1 and 2 Port 3 Assembly Model Code* 3/8” NPTF 3/8” NPTF FRDA-LAN-BAB 1/2” NPTF 1/2” NPTF FRDA-LAN-BAC 3/4” NPTF 1/2” NPTF FRDA-LAN-BAD SAE-8 SAE-8 FRDA-LAN-BAJ SAE-10 SAE-10 FRDA-LAN-BAK SAE-12 SAE-10 FRDA-LAN-BAL *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Mounting Holes: .42 diameter through hole. 2 places. 0 L Control 2.00 Max. 2 .50 1 1.62 3 3.00 0 .50 1.72 2.66 3.25 NOTES: Page 134 for cartridge model FR*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. 136 US Selected Assemblies Catalogue #999-901-192 THREE PORT PRIORITY FLOW CONTROL APPLICATIONS (90 DEGREE, HIGH CAPACITY PORT 3 BODIES) BYPASS / RESTRICTIVE FIXED ORIFICE Go to www.sunhydraulics.com for more product information and pricing. .2-25 GPM 3 Cavity T-17A 2.25 2 G 1 1.12 0 Ports 1 and 2 Port 3 Assembly Model Code* 3/4” NPTF 3/4” NPTF FREA-LAN-HED 1” NPTF 3/4” NPTF FREA-LAN-HEE 1 1/4” NPTF 3/4” NPTF FREA-LAN-HEF SAE-12 SAE-12 FREA-LAN-HEL SAE-16 SAE-12 FREA-LAN-HEM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Mounting Holes: .42 diameter through hole, 2 places. 0 L Control 2.16 Max. 2 .75 1 2.00 G 3 4.00 1.19 0 2.12 .2-50 GPM 3.44 4.25 Cavity T-19A 3 3.00 2 G 1 1.50 0 Ports 1 and 2 Port 3 Assembly Model Code* 1” NPTF 1” NPTF FRFA-LAN-KEE 1 1/4” NPTF 1” NPTF FRFA-LAN-KEF SAE-20 SAE-16 FRFA-LAN-KEN Mounting Holes: .42 diameter through hole, 2 places. 0 .50 L Control 2.56 Max. 2 1 2.50 G 3 5.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 1.06 2.50 4.31 5.25 NOTES: Page 134 for cartridge model FR*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 137 PRIORITY FLOW CONTROL Line Mounted Assemblies PRIORITY FLOW CONTROL Line Mounted Assemblies THREE PORT PRESSURE-COMPENSATED PRIORITY FLOW CONTROL APPLICATIONS (RELIEF ON CONTROLLED PORT BODIES) UP TO 6.5 GPM PRIORITY FLOW Go to www.sunhydraulics.com for more product information and pricing. .1-6.0 GPM G Cavity T-11A CF 1.50 EF T P 0 1.69 Ports (EF) Excess Flow & (P) Pump Ports (CF) Control Flow & (T) Tank Assembly Model Code* 1/4” NPTF 1/4” NPTF YRDR-LAN-LA 3/8” NPTF 3/8” NPTF YRDR-LAN-LB 1/2” NPTF 3/8” NPTF YRDR-LAN-LC SAE-6 SAE-6 YRDR-LAN-LI SAE-8 SAE-8 YRDR-LAN-LJ SAE-10 SAE-8 YRDR-LAN-LK 3.62 Mounting Holes: .34 diameter through hole. 2 places. 3.62 3.25 L Control 1.69 Max. EF P 2.12 1.94 Max. T L Control CF 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. UP TO 12.5 GPM PRIORITY FLOW .97 1.69 0 2.66 3.25 .1-12.0 GPM G 1/4” NPTF Gauge Port G Cavity T-2A CF 1.50 EF T P 0 1.69 Ports (EF) Excess Flow & (P) Pump Ports (CF) Control Flow & (T) Tank Assembly Model Code* 1/2” NPTF 1/2” NPTF YREM-LAN-LC 3/4” NPTF 1/2” NPTF YREM-LAN-LD SAE-10 SAE-10 YREM-LAN-LK SAE-12 SAE-10 YREM-LAN-LL 3.62 Mounting Holes: .34 diameter through hole. 2 places. 3.62 3.25 L Control 1.69 Max. EF P 2.12 1.94 Max. 1/4” NPTF Gauge Port G *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. UP TO 25 GPM PRIORITY FLOW T L Control 0 CF .97 1.69 0 .2-25 GPM G 2.66 3.25 Cavity T-17A CF 2.25 EF T P 0 Ports (EF) Excess Flow & (P) Pump Ports (CF) Control Flow & (T) Tank Assembly Model Code* 3/4” NPTF 3/4” NPTF YRFF-LAN-LD 5.25 1” NPTF 3/4” NPTF YRFF-LAN-LE 4.50 1 1/4” NPTF 3/4” NPTF YRFF-LAN-LF SAE-12 SAE-12 YRFF-LAN-LL SAE-16 SAE-12 YRFF-LAN-LM 0 2.09 5.25 Mounting Holes: .41 diameter through hole. 2 places. L Control 2.38 Max. EF P 3.25 L Control 1.94 Max. G *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. T 1/4” NPTF Gauge Port CF 0 0 .88 3.19 4.00 NOTES: Page 134 for cartridge model FR*A-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. 138 US Selected Assemblies Catalogue #999-901-192 Sandwich Assemblies Page 140 142 143 Technical Product Information Studkits Studrod Length Determination Chart Sandwich Assemblies Body Type Page Body Type Page 145 147 148 149 150 ISO 07/CETOP 7 Valves Relief Sequence Reducing Reducing/Relieving Counterbalance 183 185 186 187 188 151 Pilot-to-Open Check 189 152 153 Check Flow Control 190 191 154 Circuit Saver 192 ISO 08/CETOP 8 Valves Relief Sequence Reducing Reducing/Relieving Counterbalance Pilot-to-Open Check Check Flow Control Circuit Saver 193 195 196 197 198 199 200 201 202 ISO 03/CETOP 3 Valves Relief Relief, Vented Sequence Reducing Reducing/Relieving Counterbalance and Vented Counterbalance Pilot-to-Open Check Check Flow Control and Priority Flow Control Flow Control Circuit Saver 155 158 ISO 05/CETOP 5 Valves Relief Relief, Vented Sequence Reducing Reducing/Relieving Counterbalance Pilot-to-Open Check Check Flow Control 161 163 164 165 166 167 168 169 170 ISO 05 with X and Y Valves Relief Sequence Reducing Reducing/Relieving Counterbalance Pilot-to-Open Check Check Flow Control 173 175 176 177 178 179 180 181 US Selected Assemblies Catalogue #999-901-192 139 Sandwich Bodies TECHNICAL PRODUCT INFORMATION Click Here for MOUNTING and ASSEMBLY of SANDWICH BODIES Technical Tips See Product > Technical Information > Technical Tips for Sun Products 140 US Selected Assemblies Catalogue #999-901-192 Sandwich Bodies TECHNICAL PRODUCT INFORMATION Click Here for MOUNTING and ASSEMBLY of SANDWICH BODIES Technical Tips See Product > Technical Information > Technical Tips for Sun Products US Selected Assemblies Catalogue #999-901-192 141 Sandwich Bodies TECHNICAL PRODUCT INFORMATION Click Here for MOUNTING and ASSEMBLY of SANDWICH BODIES Technical Tips See Product > Technical Information > Technical Tips for Sun Products 142 US Selected Assemblies Catalogue #999-901-192 Sandwich Bodies TECHNICAL PRODUCT INFORMATION Click Here for MOUNTING and ASSEMBLY of SANDWICH BODIES Technical Tips See Product > Technical Information > Technical Tips for Sun Products US Selected Assemblies Catalogue #999-901-192 143 Sandwich Bodies NOTES 144 US Selected Assemblies Catalogue #999-901-192 ISO 03 / CETOP 3 RELIEF VALVES (SIDE PORTED SUBPLATE / REAR PORTED SUBPLATE / SIDE PORTED SUBPLATE WITH P AND T IN BASE) T-10A Cavity All subplates shown below are 3.5” wide. PILOT OPERATED DIRECT ACTING Function 2.00 p t b a P A B T Ports A, B, P, T 3/8” NPTF SAE-8 Assembly Model Code* RPEC-LAN-FSB RPEC-LAN-FSJ 0 Mounting Holes: .28 diameter through hole. 4 places 3.50 3.17 2.38 B 1.12 A .33 0 L Control 2.35 Max. t a *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. P to T T 1.00 G b p Gauge Port 1/4” NPTF 0 .38 Assembly Model Code* RDDA-LAN-FSB RDDA-LAN-FSJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. P 1.25 Ports A, B, P, T 3/8” NPTF SAE-8 2.00 p t b G P Ports A, B, P, T 3/8” NPTF SAE-8 T B Function 2.00 a A Assembly Model Code* RPEC-LAN-FRB RPEC-LAN-FRJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. P to T 1.00 0 Mounting Holes: .28 diameter through hole. 4 places. L Control 3.50 3.17 2.35 Max. t a 1.14 b p .33 0 0 .38 Ports A, B, P, T 3/8” NPTF SAE-8 Assembly Model Code* RDDA-LAN-FRB RDDA-LAN-FRJ Gauge Port 1/4” NPTF *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.00 NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information and pricing. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 145 ISO 03 / CETOP 3 Sandwich Assemblies ISO 03 / CETOP 3 RELIEF VALVES T-10A Cavity All sandwich bodies shown below are 1.75” wide PILOT OPERATED b Function a Gauge Port 1/4” NPTF 1.70 P RELIEF NOTCH 1 G T B A P RELIEF NOTCH 1 0 RPEC-LAN-FBP .05 (4) – 012 O–rings Function a G Gauge Port 1/4” NPTF A to T (High Capacity) B to T (High Capacity) 1.70 2 1 1 G 2 P B T 0 A NOTCH RPEC-LAN-FBA .05 2 1 B G 1.70 G 0 A 1 A to B (High Capacity) B to A (High Capacity) P RELIEF NOTCH L Control 2.35 Max. 2.25 Assembly Model Code* RPEC-LAN-FBC b (4) – 012 O–rings RDDA-LAN-FBC *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a 2 1.70 A to B and B to A (High Capacity) (Cross-Port) 2 t .05 Assembly Model Code* .33 Locating Pin NOTCH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p RDDA-LAN-FBA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Gauge Port 1/4” NPTF 2 T Assembly Model Code* Function a 1 P (4) – 012 O–rings P RELIEF NOTCH b L Control 2.35 Max. .33 Locating Pin 2.25 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. t P RELIEF NOTCH 1 Assembly Model Code* p RDDA-LAN-FBP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. P RELIEF NOTCH b t Assembly Model Code* .33 Locating Pin NOTCH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p L Control 2.35 Max. 2.25 Assembly Model Code* 2 P P to T 2 t 2 p DIRECT ACTING 2 NOTCH 1 1 0 P T B L Control 2.35 Max. A Assembly Model Code* 2.25 .69 .69 NOTCH RPEC-LAN-FBY .05 t b RDDA-LAN-FBY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a 1.70 A and B to T (High Capacity) 2 NOTCH 1 P T B 1 0 A Assembly Model Code* L Control 2.35 Max. 1.00 2.25 1.00 .05 L Control 2.35 Max. Locating Pin NOTCH RPEC-LAN-FBX *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Assembly Model Code* Locating Pin (4) – 012 O–rings *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p L Control 2.35 Max. 2 ISO 03 / CETOP 3 Sandwich Assemblies (4) – 012 O–rings Assembly Model Code* RDDA-LAN-FBX *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 146 US Selected Assemblies Catalogue #999-901-192 ISO 03 / CETOP 3 RELIEF VALVES, VENTED T-11A Cavity All sandwich bodies shown below are 1.75” wide PILOT OPERATED b Function 1.70 a NOTCH t RVCA 2 p 2 1 0 1 P T B A NOTCH L Control 1.81 Max. .80 2.25 1.05 P to T (Normally Open, Solenoid Vented) 2.92 NOTCH Assembly Model Code* Locating Pin .05 XRCO-LAN-HA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. (4) – 012 O–rings Operating pressure is limited to 5000 psi. Coil must be selected separately. See page 248. Function b 1.70 a NOTCH t RVCA 2 p 2 1 1 0 P T B A 2.92 Assembly Model Code* NOTCH Locating Pin NOTCH .05 XRCO-LAN-CA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 1.81 Max. .80 2.25 1.05 P to T (Normally Closed, Solenoid Vented) (4) – 012 O–rings Operating pressure is limited to 5000 psi. Coil must be selected separately. See page 248. Function b a P to T (Externally Vented) 1.70 SAE-6 Vent Port NOTCH t 2 1 P T B A 1 0 NOTCH 2.25 Vent Port Assembly Model Code* SAE-6 RVCA-LAN-EBC 2 p .39 NOTCH .80 L Control 1.81 Max. Locating Pin (4) – 012 O–rings .05 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 12 for cartridge model RV*A-*** show performance curves, technical tips, and options. Select Solenoid Connector Option from Page 248. See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. US Selected Assemblies Catalogue #999-901-192 147 ISO 03 / CETOP 3 Sandwich Assemblies ISO 03 / CETOP 3 SEQUENCE VALVES T-11A Cavity All sandwich bodies shown below are 1.75” wide PILOT OPERATED DIRECT ACTING Function p t b Gauge Port 1/4” NPTF a 2 1.70 In to P 2 G 1 P T B A NOTCH 1 0 2.25 Assembly Model Code* NOTCH RSDC-LAN-EBW/M t b a SXCA-LAN-EBW (4) – 012 O–rings .05 1.70 NOTCH p Assembly Model Code* Locating Pin *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function In to A (Reverse Free Flow Check) 2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 2.40 Max. .66 2 “B” PORT CONTROL 1 CXCA 1 0 L Control 1.81 Max. 2 P T B A NOTCH 2.25 1.31 Assembly Model Code* .88 NOTCH RSDC-LAN-EB4 b (4) – 012 O–rings 2 1.70 Out of A (Reverse Free Flow Check) “A” PORT CONTROL CXCD “B” PORT CONTROL 1 1 1.70 2 P T B A .72 .88 Assembly Model Code* RSDC-LAN-EB5 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function In to B (Reverse Free Flow Check) a 1 Assembly Model Code* SXCA-LAN-EB4 .05 NOTCH t .72 Locating Pin *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p Out of B (Reverse Free Flow Check) “A” PORT CONTROL 1 2 ISO 03 / CETOP 3 Sandwich Assemblies NOTCH 2.25 1.31 NOTCH L Control 1.81 Max. Locating Pin .05 (4) – 012 O–rings *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Assembly Model Code* SXCA-LAN-EB5 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Pages 20 and 29 for cartridge models RS*C-***, SX*A-*** and SC*A-*** show performance curves, technical tips, and options. See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 148 US Selected Assemblies Catalogue #999-901-192 ISO 03 / CETOP 3 REDUCING VALVES T-11A Cavity All sandwich bodies shown below are 1.75” wide PILOT OPERATED b Function a Gauge Port 1/4” NPTF 2 G 1.70 On P Drained to T 2 t p 1 T P B A 1 0 L Control 1.81 .66 Max. Assembly Model Code* NOTCH 2.25 PBDB-LAN-EBP NOTCH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b Locating Pin (4) – 012 O–rings .05 Function a 2 Gauge Port 1/4” NPTF 1.70 2 G 1 On A Drained to B On B Drained to A 4 “A” PORT CONTROL G 3 P T B NOTCH 1 0 L Control 1.81 Max. A Assembly Model Code* 2.25 1.31 Locating Pin NOTCH PBDB-LAN-EBA .05 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. (4) – 012 O–rings Function t b a 1.70 “A” PORT CONTROL 1 1 P T B 0 L Control 2.40 Max. A Assembly Model Code* 1.31 2.25 .88 NOTCH PBDB-LAN-EB2 t b a P T B A .05 (4) – 012 O–rings Function 1.70 0 .72 Assembly Model Code* 2.25 .88 a (4) – 012 O–rings Function 1.70 2 2 1 1 P T B A Assembly Model Code* PBDB-LAN-EBY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 1.81 Max. Locating Pin .05 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. b 1.31 NOTCH PBDB-LAN-EB3 t On B Drain to T (Reverse Free Flow Check) “B” PORT CONTROL 1 NOTCH CXDA 1 p .72 Locating Pin 2 p CXDA NOTCH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: On A Drain to T (Reverse Free Flow Check) 2 p On A and B (Drains to Opposite Port) NOTCH 0 L Control 1.81 Max. 1.31 2.25 NOTCH .05 1.31 L Control 1.81 Max. Locating Pin (4) – 012 O–rings Page 34 for cartridge model PB*B-*** show performance curves, technical tips, and options. See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 149 ISO 03 / CETOP 3 Sandwich Assemblies ISO 03 / CETOP 3 REDUCING / RELIEVING VALVES T-11A Cavity All sandwich bodies shown below are 1.75” wide PILOT OPERATED p b t DIRECT ACTING a Function On P Tank to T, Drained at T Gauge Port 1/4” NPTF G 2 1.70 2 1 P B T A 1 0 L Control 2.40 .66 Max. Assembly Model Code* NOTCH PPDB-LAN-EBP NOTCH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b PRDB-LAN-EBP Locating Pin *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. (4) – 012 O–rings .05 a Function Gauge Port 1/4” NPTF 2 1 Assembly Model Code* 2.25 1.70 On A Tank to B 2 On B Tank to A G 4 “A” PORT CONTROL G 3 P T B A Assembly Model Code* b .05 (4) – 012 O–rings PRDB-LAN-EBA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 1.70 a Assembly Model Code* Locating Pin NOTCH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. t 2.25 1.31 PPDB-LAN-EBA p NOTCH 1 0 L Control 2.40 Max. 2 On A Tank to T (Reverse Free Flow Check) 2 “A” PORT CONTROL 1 1 P T B 0 L Control 2.40 Max. A Assembly Model Code* 1.31 2.25 .88 NOTCH PPDB-LAN-EB2 t b PRDB-LAN-EB2 (4) – 012 O–rings 1.70 a 2 B A .72 2.25 .88 PPDB-LAN-EB3 2 B *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a A Assembly Model Code* 1.70 On A and B Tanks and Drains to Opposite Port NOTCH 0 L Control 1.81 Max. 1.31 2.25 1.31 NOTCH PPDB-LAN-EBY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: PRDB-LAN-EB3 (4) – 012 O–rings 1 T Assembly Model Code* Locating Pin .05 1 P L Control 2.40 Max. 2 b 1.31 NOTCH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. t Function On B Tank to T, Drained to T (Reverse Free Flow Check) 0 Assembly Model Code* p *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. “B” PORT CONTROL 1 NOTCH CXDA T Assembly Model Code* .05 1 P .72 Locating Pin *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p CXDA NOTCH 2 ISO 03 / CETOP 3 Sandwich Assemblies .05 L Control 2.40 Max. Locating Pin (4) – 012 O–rings Assembly Model Code* PRDB-LAN-EBY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Page 42 for cartridge models PP*B-*** and PR*B-*** show performance curves, technical tips, and options. See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 150 US Selected Assemblies Catalogue #999-901-192 ISO 03 / CETOP 3 COUNTERBALANCE / VENTED COUNTERBALANCE VALVES T-11A / T21A Cavity All sandwich bodies shown below are 1.75” wide PILOT RATIOS 2.3:1, 4.5:1 and 10:1 (CB**) and 5:1 and 2:1 (CW**) PILOT RATIOS 3:1 and 1.5:1 (CB**) and 3:1 and 1:1 (CW**) p t b Function STANDARD a 2 4 1.70 On B Pilot from A 2 G 3 P T B “A” PORT CONTROL A 1 0 Assembly Model Code* 1.28 Max. L Control CBC*-LHN-EBA *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. t b NOTCH 1.31 Assembly Model Code* 2.25 NOTCH .05 Locating Pin CBC*-LJN-EBA (4) – 012 O–rings *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a 2 1 1.70 On A and B (Cross-Piloted) 2 p On A Pilot from B Gauge Port 1/4” NPTF G 1 1 NOTCH 0 P T B A 1.28 Max. L Control Assembly Model Code* 1.31 2.25 NOTCH CBC*-LHN-EBY b (4) – 012 O–rings VENTED a 1.70 Assembly Model Code* CBC*-LJN-EBY *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function On A Pilot from B, Vent to T 2 t 1.28 Max. L Control Locating Pin .05 *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p 1.31 2 1 P T B A 1 0 Assembly Model Code* 1.72 Max. L Control CWC*-LHN-MBA b 2 T B .05 (4) – 012 O–rings 1.70 0 A 1 2.25 1.72 Max. L Control Locating Pin t b .05 (4) – 012 O–rings 1.70 2 1 1 0 P T B A Assembly Model Code* CWC*-LHN-MBY 1.72 Max. L Control 1.81 CWC*-LGN-MBB *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. On A and B (Cross-Piloted, vents to T) NOTCH 2.25 .05 1.81 1.72 Max. L Control Locating Pin (4) – 012 O–rings *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Assembly Model Code* Function a 2 p Function On B Pilot from A, Vent to T 1.64 NOTCH CWC*-LHN-MBB *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTCH Assembly Model Code* *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. CWC*-LGN-MBA Locating Pin a 1 P Assembly Model Code* 2 t 2.25 NOTCH *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p NOTCH 1.64 Assembly Model Code* CWC*-LGN-MBY *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Page 50 for cartridge model CB**-*** and page 70 for cartridge model CW**-*** show performance curves, technical tips, and options. See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 151 ISO 03 / CETOP 3 Sandwich Assemblies ISO 03 / CETOP 3 PILOT-TO-OPEN CHECK VALVES T-11A / T-21A Cavity All sandwich bodies shown below are 1.75” wide PILOT OPERATED p t b VENTED STANDARD a 2 1 1.70 4 G P T B 1 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. a 2.25 NOTCH .05 (4) – 012 O–rings Function 1.70 2 1 1 P T B Locating Pin On A and B (Cross-Piloted) 2 b NOTCH X Control 1.31 .50 Max. CKCB-XCN-EBA t On B Pilot from A “A” PORT CONTROL A Assembly Model Code* p On A Pilot from B Gauge Port 1/4” NPTF G 3 Function 2 NOTCH 0 A X Control X Control 1.31 Assembly Model Code* 2.25 1.31 1.81 Max. Locating Pin .50 Max. NOTCH CKCB-XCN-EBY .05 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. (4) – 012 O–rings VENTED Function On A Pilot from B Vent to T 1.70 p t b 2 a 2 0 NOTCH 1 1 1.64 P T B 2.25 X Control 1.15 Max. A NOTCH .05 (4) – 012 O–rings 1.70 p t b 0 1 2 B Function On B Pilot from A, Vent to T 1.64 X Control 1.15 Max. Locating Pin A NOTCH .05 b a 2 1 P T B CVCV-XCN-MBB Function On A and B Cross-Piloted, Vents to T 2 t Assembly Model Code* *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. (4) – 012 O–rings 1.70 p CVCV-XCN-MBA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTCH 2.25 T Assembly Model Code* a 1 P Locating Pin 2 ISO 03 / CETOP 3 Sandwich Assemblies A 0 1.15 Max. X Control 1 1.81 NOTCH 1.81 2.25 1.15 Max. X Control Locating Pin NOTCH .05 (4) – 012 O–rings Assembly Model Code* CVCV-XCN-MBY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 78 for cartridge models CK**-*** and page 94 for cartridge model CV*V-*** show performance curves, technical tips, and options. See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 152 US Selected Assemblies Catalogue #999-901-192 ISO 03 / CETOP 3 Sandwich Assemblies ISO 03 / CETOP 3 CHECK VALVES T-13A / T-5A Cavity All sandwich bodies shown below are 1.75” wide FREE FLOW PORT 1 TO 2 t b Function a 2 1.70 On P 2 p On T 1 1 P T B NOTCH 1 0 2 T 2.25 A Assembly Model Code* .72 .14 Max. NOTCH CXDA-XCN-GDP Locating Pin (4) – 012 O–rings .05 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function b p a t b a 1.70 NOTCH A t 4 2 3 On A Free Flow Into Valve 2 p 1 On A Free Flow Out Valve 1 3 4 2 P T B P A 1 0 T B NOTCH B A 2.25 Assembly Model Code* On B Free Flow Into Valve NOTCH CXDA-XCN-GDA On B Free Flow Out Valve .50 .72 Max Locating Pin (4) – 012 O–rings .05 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. b a 1.70 NOTCH t Function On A and B, Free Flow Out of Valve 2 p 2 1 On A and B, Free Flow Into Valve 1 1 0 NOTCH 2 P T B A 2.25 .72 .69 Max. Assembly Model Code* .69 .72 Max. NOTCH CXDA-XCN-GDY Locating Pin .05 (4) – 012 O–rings *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. t b a P T B A 1.70 2 1 NOTCH 1 0 1.56 CXFA-XAN-GDF (4) – 012 O–rings Function a 1.70 B PORT CONTROL NOTCH b .05 T to A 2 t .658 Max. Locating Pin NOTCH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p 1.56 2.25 .658 Max. Assembly Model Code* Function T to A and B (High Capacity) 2 p 1 2 T to B 2 0 1 P T B A 1 A PORT CONTROL NOTCH .72 .14 Max Assembly Model Code* 2.25 NOTCH CXDA-XAN-GDW Locating Pin .05 (4) – 012 O–rings *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** show performance curves, technical tips, and options. See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 153 ISO 03 / CETOP 3 FLOW CONTROL / PRIORITY FLOW CONTROL VALVES T-13A / T-11A Cavity All sandwich bodies shown below are 1.75” wide FULLY ADJUSTABLE NEEDLE PRESSURE COMPENSATED WITH REVERSE FREE FLOW CHECK FULLY ADJUSTABLE NEEDLE p t b Function a 3 1.70 Meter-In P 2 4 Meter-Out T 2 1 0 P T B A Note: Reverse Checks on FDBA-LAN-GBP Only “T” PORT CONTROL 1 NOTCH L Control 2.03 Max. .14 2.25 Assembly Model Code* NOTCH NFCC-LCN-GBP .05 b *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. a 1.19 B1 NOTCH t FDBA-LAN-GBP (4) – 012 O–rings *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p Assembly Model Code* Locating Pin Function Bleed-Off A to B and B to A 2 2 A1 1 0 1 P T B NOTCH L Control 1.97 Max. .25 A 2.25 Assembly Model Code* NOTCH NFCC-LCN-GBS Locating Pin .05 (4) – 012 O–rings *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. t b Function a 2 1.70 NOTCH p Bleed-Off A to T 2 “B” PORT CONTROL 1 Bleed-Off B to T 1 2 “A” PORT CONTROL 1 NOTCH 0 P T B A .14 Assembly Model Code* NOTCH Locating Pin NFCC-LCN-GBW .05 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b L Control 2.03 Max. 2.25 a (4) – 012 O–rings Function 1.70 2 Bleed-Off A and B to T 2 1 P T B 1 0 A L Control 2.03 Max. Assembly Model Code* t b a .05 Function Priority Flow on P, Bypass to T 2 B Locating Pin PRIORITY FLOW CONTROL FIXED ORIFICE 1.70 T L Control 2.03 Max. (4) – 012 O–rings 1 P .81 NOTCH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p NOTCH 2.25 .81 NFCC-LCN-GBX 2 ISO 03 / CETOP 3 Sandwich Assemblies A Assembly Model Code* 0 NOTCH 2.25 FRCA-LAN-WBN** *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1 .66 NOTCH .05 L Control 2.20 Max. Locating Pin (4) – 012 O–rings **Customer must specify priority flow. NOTES: Page 110 for cartridge model NF*C-***, page 126 for FD*A-***, and page 134 for FR*A-*** show performance curves, technical tips, and options. See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 154 US Selected Assemblies Catalogue #999-901-192 ISO 03 / CETOP 3 FLOW CONTROL VALVES T-13A Cavity All sandwich bodies shown below are 1.75” wide FULLY ADJUSTABLE NEEDLE WITH REVERSE FREE FLOW CHECK FULLY ADJUSTABLE, PRESSURE COMPENSATED WITH FREE FLOW CHECK Function a p t b a 3 1 2 Meter-In A 1.70 NOTCH b t 4 METER IN A 4 1 B T Meter-Out A 2 3 P 2 p A P T B 1 0 A Meter-In B METER OUT B NOTCH 2.25 Assembly Model Code* .50 NOTCH b .05 (4) – 012 O–rings FDBA-LAN-GBA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a 1.70 METER OUT NOTCH t Assembly Model Code* Meter-In A and B 2 p Meter-Out B Locating Pin NCCB-LCN-GBA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 2.03 Max. 2 1 Meter-Out A and B 1 METER IN 1 0 2 T B L Control 2.03 Max. A Assembly Model Code* 2.25 .69 NCCB-LCN-GBY b L Control 2.03 Max. Assembly Model Code* Locating Pin (4) – 012 O–rings .05 FDBA-LAN-GBY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a 2 1.70 “B” PORT CONTROL NOTCH t .69 NOTCH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p NOTCH 1 Bleed-Off A to T 2 P Bleed-Off B to T 1 2 1 0 P T B “A” PORT CONTROL NOTCH A 2.25 .14 Assembly Model Code* NOTCH NCCB-LAN-GBW *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 2.03 Max. (4) – 012 O–rings .05 Assembly Model Code* Locating Pin FDBA-LAN-GBW *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function t b a P T B A 1.70 2 1 Assembly Model Code* NCCB-LAN-GBX *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 L Control 2.03 Max. Bleed-Off A and B to T 2 p 1 NOTCH 2.25 .81 NOTCH .81 L Control 2.03 Max. Locating Pin Assembly Model Code* FDBA-LAN-GBX .05 (4) – 012 O–rings *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 110 for cartridge model NC*B-*** and page 126 for FD*A-*** show performance curves, technical tips, and options. See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 155 ISO 03 / CETOP 3 Sandwich Assemblies ISO 03 / CETOP 3 Sandwich Assemblies ISO 03 / CETOP 3 FLOW CONTROL VALVES (RAPID ADVANCE - FINE FEED) T-13A Cavity All sandwich bodies shown below are 1.75” wide FULLY ADJUSTABLE, PRESSURE COMPENSATED WITH FREE FLOW CHECK a t p b .69 2.91 Max 1.75 t FDBA Shown a FDBA Meter-Out T, Solenoid Normally Closed b p FDBA Shown A T P B 0 2.753.25 .05 0 .50 0 METER-OUT T (NOTCH) 1.70 Assembly Model Code* X2CD-LAN-CA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Meter-In P, Solenoid Normally Closed METER-IN P (NOTCH) L Control 2.00 Max. -012 O-Rings Locating Pin Typ (4) Places Coil must be selected separately. See page 248. NOTES: Page 126 for cartridge models FD*A-*** show performance curves, technical tips, and options. See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information and pricing. 156 US Selected Assemblies Catalogue #999-901-192 ISO 03 / CETOP 3 FLOW CONTROL VALVES (RAPID ADVANCE - FINE FEED) T-13A Cavity All sandwich bodies shown below are 1.75” wide FULLY ADJUSTABLE, PRESSURE COMPENSATED WITH FREE FLOW CHECK b p Function Meter-In A, Solenoid Normally Closed a FDBA Shown L Control 2.03 Max. METER-OUT B (NOTCH) t Meter-Out A, Solenoid Normally Closed METER-IN A (NOTCH) Meter-In B, Solenoid Normally Closed FDBA FDBA Shown Locating Pin -012 O-Rings Typ (4) Places .72 1.75 a b p 0 0 3.25 3.11 .86 B P A Assembly Model Code* X4CD-LAN-CA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 2.03 Max. .05 0 METER-IN B (NOTCH) T 2.91 Max t FDBA Shown FDBA Shown Meter-Out B, Solenoid Normally Closed METER-OUT A (NOTCH) 1.70 Coil must be selected separately. See page 248. NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** show performance curves, technical tips, and options. See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information and pricing. US Selected Assemblies Catalogue #999-901-192 157 ISO 03 / CETOP 3 Sandwich Assemblies ISO 03 / CETOP 3 CIRCUIT SAVERS (PRESSURE COMPENSATOR / REGENERATIVE / LOAD SENSING / PILOT CHOKE PACK) T-11A / T-13A Cavity p t b All sandwich bodies shown below are 1.75” wide Function a YFCG: Pressure Compensator (Restrictive), 200 psi 2 2.50 2 1 LPDC-XHN 2 Output 1 P T B YFCJ: Pressure Compensator (Restrictive), 200 psi with external Load-Sensing Port CSAB-*XN A 1 0 Output Port YFCJ: SAE-4 NOTCH External Shuttle Port Assembly Model Code* 2.25 None YFCG-XHN-AA NOTCH SAE-4 YFCJ-XHN-AA .75 .50 Locating Pin .05 (4) – 012 O–rings *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. t b a 2 1.19 B1 NOTCH p Function Shuttle A and B (Output External) Output 1 0 P T B 2 ISO 03 / CETOP 3 Sandwich Assemblies Output Port SAE-4 A1 NOTCH 1 A 2.25 Assembly Model Code* .66 .25 Max. NOTCH CSAA-BXN-GBS Locating Pin (4) – 012 O–rings .05 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b a CODA-XEN 1.70 1 CBCA-LHN Function B to A Pressure Sensing Regenerative Circuit A to B Pressure Sensing Regenerative Circuit “B” PORT CONTROL 1 P T B A 1 0 Assembly Model Code* NOTCH L Control 1.28 Max. Locating Pin 2.25 .50 .94 1.31 NOTCH YDCA-LHN-AA .05 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. (4) – 012 O–rings Function p b a t PBBB-LAN NFBC-LCN Pilot Choke Pack 1.18 P B A T Assembly Model Code* 0 L Control 1.94 Max. L Control 1.56 .38 Max. Locating Pin 2.25 .87 NOTCH YNAA-LDN-AA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. (Used typically to control main stage shift time on pilot operated ISO/CETOP directional valves.) NOTCH .05 (4) – 012 O–rings NOTES: See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 158 US Selected Assemblies Catalogue #999-901-192 ISO 03 / CETOP 3 Sandwich Assemblies ISO 03 / CETOP 3 CIRCUIT SAVERS (TAP IN MANIFOLD / ADAPTOR PLATE / COVER PLATE) All sandwich bodies shown below are 1.75” wide Function p t b a A and B Tap in Manifold .94 A B P T B Port Port A 0 A B NOTCH 2.25 Ports A, B Assembly Model Code* 1/4” NPTF ZWV SAE-4 ZUO NOTCH Locating Pin .05 (4) – 012 O–rings *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p a t b Function a B P B T A P A T P A T A P B T B P T B A P T B External Port Assembly Model Code* 1/4” NPTF ZWW SAE-4 ZPT P and A Tap in Manifold .94 P b NOTCH t A p P and B Tap in Manifold Port Port 0 A P NOTCH B T and A Tap in Manifold 2.25 T and B Tap in Manifold Locating Pin (5) – 012 O–rings .05 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function ISO 03 p t b Adaptor from ISO 05 to ISO 03. a 1.44 P T B A 0 ISO 05 (5) – 014 O–rings Assembly Model Code* 3.00 ZVT *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function p t b a Cover Plate with All Ports Blocked .94 0 P T B A 2.25 Assembly Model Code* ZJR NOTCH NOTCH .05 Locating Pin (4) – 012 O–rings *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTE: See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 159 Sandwich Assemblies NOTES 160 US Selected Assemblies Catalogue #999-901-192 ISO 05 / CETOP 5 RELIEF VALVES (SIDE PORTED SUBPLATE / REAR PORTED SUBPLATE / SIDE PORTED SUBPLATE WITH GASKET MOUNTED TANK PORT) T-10A Cavity All subplates shown below are 4.5” wide PILOT OPERATED DIRECT ACTING Function p t b Mounting Holes: .44 diameter through hole. 4 places. a 4.06 A P A B T T 3.31 t 2.16 B a b P to T L Control 1.75 Max p Ports A, B, P, T Assembly Model Code* RPEC-LAN-FSC RPEC-LAN-FSK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1/2” NPTF SAE-10 Ports A, B, P, T .44 0 P 4.00 3.56 2.31 1.19 0 .44 Assembly Model Code* RDDA-LAN-FSC RDDA-LAN-FSK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1/2” NPTF 0 1.25 1.94 SAE-10 Function p t b a P T B A Mounting Holes: .44 diameter through hole. 4 places. 4.50 4.06 L Control 1.75 Max t G b 1.94 Ports A, B, P, T a p Assembly Model Code* 1.34 2.12 RPEC-LAN-FRC RPEC-LAN-FRK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports A, B, P, T .44 0 G 1/2” NPTF SAE-10 P to T RDDA-LAN-FRC RDDA-LAN-FRK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1/2” NPTF 0 .622.12 0 2.19 1.06 4.00 .44 3.56 1/4” NPTF Gauge Port Assembly Model Code* SAE-10 Function p t b a P A B 4.50 4.06 A T T t 2.16 Ports A, B, P, T Assembly Model Code* RPEC-LAN-FTC RPEC-LAN-FTK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1/2” NPTF SAE-10 P to T Mounting Holes: .44 diameter through hole. 4 places. B a b L Control 1.75 Max 2.50 p 1.31 .44 0 P 4.00 3.56 O-ring Seal 2.31 1.19 0 .44 0 1.25 1.94 Tank Port with O-ring Groove Ports A, B, P, T Assembly Model Code* RDDA-LAN-FTC RDDA-LAN-FTK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1/2” NPTF SAE-10 NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information and pricing. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 161 ISO 05 / CETOP 5 Sandwich Assemblies ISO 05 / CETOP 5 Sandwich Assemblies ISO 05 / CETOP 5 RELIEF VALVES T-10A Cavity All sandwich bodies shown below are 2.50” wide PILOT OPERATED DIRECT ACTING Function p t b a P to T Gauge Port 1/4” NPTF 1.94 G P T B A 0 Assembly Model Code* Assembly Model Code* (5) – 014 O–rings RPEC-LAN-CBE 3.00 .81 L Control 2.35 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. RDDA-LAN-CBE *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function p b t a G P B T A to T Gauge Port 1/4” NPTF 1.94 A 0 (5) – 014 O–rings Assembly Model Code* 3.00 RPEC-LAN-CBF .81 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p b t Assembly Model Code* L Control 2.35 Max. RDDA-LAN-CBF *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a Gauge Port 1/4” NPTF G P B T B to T 1.94 A 0 (5) – 014 O–rings Assembly Model Code* 3.00 RPEC-LAN-CBG .81 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b Assembly Model Code* L Control 2.35 Max. RDDA-LAN-CBG *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a A to B and B to A (Cross-port) 2.44 P T B 0 A Assembly Model Code* RPEC-LAN-CBI L Control 2.32 Max. (5) – 014 O–rings L Control 2.32 3.00 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Assembly Model Code* RDDA-LAN-CBI *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function p t b a A and B to T 1.44 0 P T B A Assembly Model Code* L Control 2.35 .81 Max. (5) – 014 O–rings 3.00 .81 RPEC-LAN-CBD Assembly Model Code* RDDA-LAN-CBD *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: L Control 2.35 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 162 US Selected Assemblies Catalogue #999-901-192 ISO 05 / CETOP 5 RELIEF VALVES T-10A Cavity/T-2A Cavity All sandwich bodies shown below are 2.50” wide PILOT OPERATED p t b DIRECT ACTING Function a Gauge Port 1/4” NPTF G 1.44 “B” RELIEVES TO “A” “A” RELIEVES TO “B” 0 P T B B to A SOLENOID VALVE G A to B SOLENOID VALVE A .05 Assembly Model Code* (5) – 014 O–rings RPEC-LAN-CBH RDDA-LAN-CBH L Control 2.32 Max. 3.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Assembly Model Code* *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function p t b a Vent Vent Port SAE-6 P to T (Externally Vented) Gauge Port 1/4” NPTF 2.44 G P T B A Vent Port 1.82 .63 Assembly Model Code* 0 (5) – 014 O–rings RVEA-LAN-BBC *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. SAE-6 3.00 1.34 L Control 2.75 Max. Function p t b 2.44 a P to T (Normally Open, Solenoid Vented) RVEA P T B 0 A (5) – 014 O–rings Assembly Model Code* 3.00 3.15 XRED-LAN-HA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.00 L Control 2.09 Max. Coil must be selected separately. See page 248. Function p t b a 2.44 RVEA P T B P to T (Normally Closed, Solenoid Vented) 0 A (5) – 014 O–rings Assembly Model Code* XRED-LAN-CA 3.00 3.15 1.00 L Control 2.09 Max. Coil must be selected separately. See page 248. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 2 for cartridge models RP*C-***, RD*A-*** and page 12 for cartridge model RV*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. US Selected Assemblies Catalogue #999-901-192 163 ISO 05 / CETOP 5 Sandwich Assemblies ISO 05 / CETOP 5 SEQUENCE VALVES T-2A Cavity All sandwich bodies shown below are 2.50” wide PILOT OPERATED DIRECT ACTING Function p t b a Gauge Port 1/4” NPTF In to P 2.44 G P T B A 0 Assembly Model Code* (5) – 014 O–rings RSFC-LAN-BBW L Control 2.06 .31 Max. 3.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b Assembly Model Code* SXEA-LAN-BBW *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Into A (Reverse Free Flow Check) a 2.44 SOLENOID VALVE Out of B (Reverse Free Flow Check) SEQUENCE INTO A CXED P T B Assembly Model Code* RSFC-LAN-BB4 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b 0 A SOLENOID VALVE SEQUENCE OUT OF B .05 L Control 2.09 Max. .15 (5) – 014 O–rings 3.00 1.10 .62 Assembly Model Code* SXEA-LAN-BB4 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Into B (Reverse Free Flow Check) a 2.44 SOLENOID VALVE Out of A (Reverse Free Flow Check) SEQUENCE INTO B CXED T B A Assembly Model Code* SOLENOID VALVE P SEQUENCE OUT OF A ISO 05 / CETOP 5 Sandwich Assemblies 0 .05 RSFC-LAN-BB5 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .62 1.10 (5) – 014 O–rings 3.00 L Control 2.09 .15 Max. Assembly Model Code* SXEA-LAN-BB5 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 20 for cartridge model RS*C-*** and SX*A-*** and page 102 for CX*D-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 164 US Selected Assemblies Catalogue #999-901-192 ISO 05 / CETOP 5 REDUCING VALVES T-2A Cavity All sandwich bodies shown below are 2.50” wide PILOT OPERATED Function t p b a G T P B On P Drained to T Gauge Port 1/4” NPTF 2.44 A 0 Assembly Model Code* (5) – 014 O–rings PBFB-LAN-BBP L Control 2.06 Max. .31 3.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function p t b a On A Drained to B Gauge Port 1/4” NPTF 1.94 G P T B A 0 Assembly Model Code* (5) – 014 O–rings L Control 1.64 3.00 Max. .50 PBFB-LAN-BBA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b Function a On B Drained to A Gauge Port 1/4” NPTF 1.94 G P T B A Assembly Model Code* (5) – 014 O–rings PBFB-LAN-BBB .50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b a L Control 1.64 Max. 3.00 Function 2.44 On A Drain to T (Reverse Free Flow Check) SOLENOID VALVE CXFA P T B PBFB-LAN-BB2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. t b (5) – 014 O–rings .05 Assembly Model Code* p 0 A L Control 2.09 Max. .15 a 3.00 1.10 .62 Function 2.44 SOLENOID VALVE CXFA P T B A Assembly Model Code* PBFB-LAN-BB3 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: On B Drain to T (Reverse Free Flow Check) 0 .05 (5) – 014 O–rings 3.00 .62 1.10 L Control 2.09 Max. .15 Page 34 for cartridge model PB*B-*** and page 102 for cartridge model CX*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 165 ISO 05 / CETOP 5 Sandwich Assemblies ISO 05 / CETOP 5 Sandwich Assemblies ISO 05 / CETOP 5 REDUCING / RELIEVING VALVES T-2A Cavity All sandwich bodies shown below are 2.50” wide PILOT OPERATED DIRECT ACTING Function p b t a G P B T On P, Tank to T Gauge Port 1/4” NPTF 2.44 A 0 Assembly Model Code* Assembly Model Code* (5) – 014 O–rings PPFB-LAN-BBP L Control 2.06 Max. .31 3.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. PRFB-LAN-BBP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function p t b a On A, Tank to T (Reverse Free Flow Check) 2.44 SOLENOID VALVE CXFA P T B A 0 Assembly Model Code* PPFB-LAN-BB2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Assembly Model Code* (5) – 014 O–rings .05 L Control 2.09 Max. .15 PRFB-LAN-BB2 3.00 1.10 .62 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function p t b a 2.44 SOLENOID VALVE On B, Tank to T (Reverse Free Flow Check) CXFA P T B A Assembly Model Code* 0 .05 (5) – 014 O–rings PPFB-LAN-BB3 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.00 .62 1.10 L Control 2.09 Max. .15 Assembly Model Code* PRFB-LAN-BB3 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 42 for cartridge models PP*B-*** and PR*B-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 166 US Selected Assemblies Catalogue #999-901-192 ISO 05 / CETOP 5 COUNTERBALANCE VALVES T-2A Cavity All sandwich bodies shown below are 2.50” wide PILOT RATIOS 3:1 (CBEA), 1.5:1 (CBEB), 2:1 (CBEY) PILOT RATIOS 2.3:1 (CBEL), 4.5:1 (CBEG), 10:1 (CBEH) Function p t b a On A, Pilot from B Gauge Port 1/4” NPTF 1.94 G P T B A 0 Assembly Model Code* Assembly Model Code* (5) – 014 O–rings L Control 1.21 Max. .50 CBE*-LHN-BBA *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. CBE*-LJN-BBA 3.00 *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function p t b a On B, Pilot from A Gauge Port 1/4” NPTF 1.94 G P T B A 0 Assembly Model Code* Assembly Model Code* (5) – 014 O–rings CBE*-LHN-BBB L Control 1.21 .50 Max. 3.00 CBE*-LJN-BBB *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a On A and B (Cross-Piloted) 1.94 P T B A 0 (5) – 014 O–rings Assembly Model Code* CBE*-LHN-BBY L Control 1.69 1.06 Max. 3.00 1.06 *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b Function a SOLENOID VALVE CXFC T B CBE*-LJN-BBY *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.94 P Assembly Model Code* L Control 1.69 Max. CXFC Cushion Lock Circuit On A and B A 0 Assembly Model Code* CBE*-LHN-BB8 *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. (5) – 014 O–rings .05 L Control 1.66 Max. 1.26 3.00 1.26 L Control 1.66 Max. Assembly Model Code* CBE*-LJN-BB8 *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CB**-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 167 ISO 05 / CETOP 5 Sandwich Assemblies ISO 05 / CETOP 5 Sandwich Assemblies ISO 05 / CETOP 5 PILOT-TO-OPEN CHECK VALVES T-2A Cavity All sandwich bodies shown below are 2.50” wide PILOT OPERATED Function p b t a Gauge Port 1/4” NPTF 1.94 On A, Pilot from B G P B T A 0 (5) – 014 O–rings Assembly Model Code* X Control .21 Max. CKEB-XCN-BBA 3.00 .50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function p b t a On B, Pilot from A Gauge Port 1/4” NPTF 1.94 G P B T A 0 (5) – 014 O–rings X Control .21 Max. Assembly Model Code* 3.00 CKEB-XCN-BBB .50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function p t b a On A and B (Cross-piloted) 1.94 P T B A Assembly Model Code* CKEB-XCN-BBY 0 X Control .69 Max. 1.06 (5) – 014 O–rings 3.00 X Control .69 Max. 1.06 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 78 for cartridge model CK**-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 168 US Selected Assemblies Catalogue #999-901-192 ISO 05 / CETOP 5 Sandwich Assemblies ISO 05 / CETOP 5 CHECK VALVES T-5A Cavity All sandwich bodies shown below are 2.50” wide FREE FLOW PORT 1 TO 2 p t b a 2.44 P T B A 0 Function On P (5) – 014 O–rings Assembly Model Code* 3.00 CXFA-XCN-DBP .518 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b a 1.94 Function On A, Free Flow Out of Valve SOLENOID VALVE B On B, Free Flow Into Valve A SOLENOID VALVE 0 P T B .05 A (5) – 014 O–rings Assembly Model Code* CXFA-XCN-DBK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b a 3.00 .658 .38 Max. Function 1.94 SOLENOID VALVE On A, Free Flow Into Valve A On B, Free Flow Out of Valve B SOLENOID VALVE 0 P T B .05 (5) – 014 O–rings A Assembly Model Code* 3.00 CXFA-XCN-DBJ .38 .658 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b a P T B A Function 2.44 0 .05 (5) – 014 O–rings Assembly Model Code* CXFA-XAN-DBW *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. T to A and B SOLENOID VALVE .658 Max. .81 3.00 .81 .658 Max. NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 169 ISO 05 / CETOP 5 FLOW CONTROL VALVES T-5A Cavity All sandwich bodies shown below are 2.50” wide FULLY ADJUSTABLE NEEDLE WITH REVERSE FREE FLOW CHECK p t b FULLY ADJUSTABLE PRESSURE COMPENSATED WITH FREE FLOW CHECK Function a 2.44 P T B A Note: No Check with NFDC Model Meter-In P 0 (5) – 014 O–rings Assembly Model Code* NFDC-LAN-DBP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p b t Assembly Model Code* L Control 2.47 Max. 3.00 FDCB-LAN-DBP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a 1.94 Meter-Out A SOLENOID VALVE Meter-In B METER-OUT A METER-IN B SOLENOID VALVE 0 P B A T Note: Pressure Compensated Symbol Not Shown .05 (5) – 014 O–rings Assembly Model Code* NCEB-LAN-DBA .38 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b Assembly Model Code* L Control 2.41 Max. 3.00 FDCB-LAN-DBA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a 1.94 Meter-In A SOLENOID VALVE METER-OUT B Meter-Out B METER-IN A SOLENOID VALVE 0 P T B A Note: Pressure Compensated Symbol Not Shown Assembly Model Code* NCEB-LAN-DBB .05 (5) – 014 O–rings L Control 2.41 Max. .38 3.00 FDCB-LAN-DBB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b Assembly Model Code* *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a 1.44 Bleed-Off A to T SOLENOID VALVE Bleed-Off B to T “A” PORT CONTROL “B” PORT CONTROL SOLENOID VALVE 0 P T B A Note: Pressure Compensated Symbol Not Shown .05 (5) – 014 O–rings Assembly Model Code* 3.00 .75 L Control 2.41 Max. Assembly Model Code* NCEB-LAN-DBC FDCB-LAN-DBC *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function a 1.94 Meter-In A and B SOLENOID VALVE METER-OUT Meter-Out A and B METER-IN P T B A Note: Pressure Compensated Symbol Not Shown Assembly Model Code* NCEB-LAN-DBY SOLENOID VALVE ISO 05 / CETOP 5 Sandwich Assemblies 0 .05 L Control 2.41 Max. .69 (5) – 014 O–rings 3.00 .69 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: L Control 2.41 Max. Assembly Model Code* FDCB-LAN-DBY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Page 110 for cartridge models NF*C-*** and NC*B-***, and page 126 for FD*B*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 170 US Selected Assemblies Catalogue #999-901-192 ISO 05 / CETOP 5 Sandwich Assemblies ISO 05 / CETOP 5 FLOW CONTROL VALVES T-13A Cavity All sandwich bodies shown below are 2.50” wide FULLY ADJUSTABLE NEEDLE 2.50 t b p a t L Control 2.41 Max. T Meter A to B Meter B to A T B A P T P B A Function .60 T 0 3.00 0 0 Assembly Model Code* SOLENOID VALVE A1 SOLENOID VALVE B1 NFCC-LCN-DBS *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.50 1.19 .05 (5) – 014 O–rings NOTES: Page 110 for cartridge models NF*C-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. US Selected Assemblies Catalogue #999-901-192 171 ISO 05 / CETOP 5 Sandwich Assemblies ISO 05 / CETOP 5 FLOW CONTROL VALVES (RAPID ADVANCE AND FEED ASSEMBLIES) All sandwich bodies shown below are 2.50” wide FULLY ADJUSTABLE, PRESSURE COMPENSATED WITH FREE FLOW CHECK T-5A Cavity FIXED ORIFICE TUNABLE, PRESSURE COMPENSATED Function Meter-Out T, Solenoid Normally Closed a t ISO 05 PATTERN .28 DIA THRU-TYP (4) PLACES b p .66 2.91 Max 2.50 FDCB Shown T T A B P A T B P .34 0 0 1.13 0 3.69 4.13 5.25 2.44 SOLENOID VALVE METER-OUT T Assembly Model Code* X3DD-LAN-CA L Control 2.09 Max 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .05 Coil must be selected separately. See page 248. Function Meter in P, Solenoid Normally Closed 2.44 a t b p SOLENOID VALVE METER-IN P FDCB Shown L Control 2.06 Max 0 A T B P .63 2.91 Max 2.50 T T A B Assembly Model Code* P X2DD-LAN-CA .34 0 0 1.16 0 3.69 4.16 5.31 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .58 2.50 2.91 Max T T D B b t p a P .34 3.42 3.86 3.98 FDCB Shown 0 .86 Assembly Model Code* 2.94 B T P Function Meter-Out A, Solenoid Normally Closed Meter-In B, Solenoid Normally Closed X6DD-LAN-CA SOLENOID VALVE METER-OUT A A SOLENOID VALVE METER-IN B L Control 2.09 Max .05 0 Coil must be selected separately. See page 248. .58 2.50 2.91 Max T T D B t b p P a FDCB Shown T B P .86 3.42 3.98 3.86 2.94 Assembly Model Code* X4DD-LAN-CA SOLENOID VALVE METER-OUT B A Function Meter-In A, Solenoid Normally Closed Meter-Out B, Solenoid Normally Closed .34 0 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. SOLENOID VALVE METER-IN A L Control 2.09 Max 0 .05 Coil must be selected separately. See page 248. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. 172 US Selected Assemblies Catalogue #999-901-192 ISO 05/CETOP 5 with X and Y U.S. Sandwich Assemblies ISO 05 / CETOP 5 WITH X AND Y RELIEF VALVES (SIDE PORTED SUBPLATE) T-10A Cavity All subplates shown below are 4.5” wide X Y PILOT OPERATED DIRECT ACTING ISO5/CETOP VERSION x p t b a Function y X P P to T Y 0 A B T Ports X, Y Assembly Model Code* 1/2” NPTF 3/4” NPTF SAE-10 SAE-12 1/4” NPTF 1/4” NPTF SAE-6 SAE-6 RPEC-LAN-ZHP RPEC-LAN-ZHQ RPEC-LAN-ZHR RPEC-LAN-ZHS 0 .44 P x Ports A, B, P, T 0 .88 1.56 3.56 p a b X t T y Y .31 2.22 t B A 4.06 4.50 Order Retainer and Seal Kits separately. (See page 141) *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports A, B, P, T Ports X, Y Assembly Model Code* 1/2” NPTF 3/4” NPTF SAE-10 SAE-12 1/4” NPTF 1/4” NPTF SAE-6 SAE-6 RDDA-LAN-ZHP RDDA-LAN-ZHQ RDDA-LAN-ZHR RDDA-LAN-ZHS *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. U.S. D05H VERSION Function P to T x p t b a X P y Y 0 1.00 A B T Assembly Model Code* 1/2” NPTF 3/4” NPTF SAE-10 SAE-12 1/4” NPTF 1/4” NPTF SAE-6 SAE-6 RPEC-LAN-ZHH RPEC-LAN-ZHJ RPEC-LAN-ZHK RPEC-LAN-ZHL 1.56 X x 1.31 p a Ports X, Y 0 .88 0 .44 P t Ports A, B, P, T 3.56 b t B 2.22 y T A 4.06 Y 4.50 1.81 Order Retainer and Seal Kits separately. (See page 141) *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports A, B, P, T Ports X, Y Assembly Model Code* 1/2” NPTF 3/4” NPTF SAE-10 SAE-12 1/4” NPTF 1/4” NPTF SAE-6 SAE-6 RDDA-LAN-ZHH RDDA-LAN-ZHJ RDDA-LAN-ZHK RDDA-LAN-ZHL *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the differences in the European and U.S. seal plates. To order seal plates separately see page 141-142. Go to www.sunhydraulics.com for more product information and pricing. US Selected Assemblies Catalogue #999-901-192 173 ISO 05/CETOP 5 with X and Y U.S. Sandwich Assemblies ISO 05 / CETOP 5 WITH X AND Y RELIEF VALVES T-3A / T-10A Cavities p t b a All sandwich bodies shown below are 2.50” wide Y PILOT OPERATED x X DIRECT ACTING Function Gauge Port 1/4” NPTF y 1.94 P to T (High Capacity) SOLENOID VALVE G X P T B A Y 0 Assembly Model Code* L Control 2.47 .88 Max. Order Retainer and Seal Kits separately. (See page 141) 3.62 RPGC-LAN-CJP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p b t a B T Y A 0 .05 Assembly Model Code* L Control 3.62 2.47 .88 Max. Order Retainer and Seal Kits separately. (See page 141) RPGC-LAN-CJA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p x b t a B T Assembly Model Code* L Control 3.62 2.47 .88 Max. Order Retainer and Seal Kits separately. (See page 141) RPGC-LAN-CJB p t B to T (High Capacity) Assembly Model Code* .05 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 Y A RDFA-LAN-CJA SOLENOID VALVE G P Assembly Model Code* Function Gauge Port 1/4” NPTF y 1.94 X A to T (High Capacity) SOLENOID VALVE G P RDFA-LAN-CJP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Gauge Port 1/4” NPTF y 1.94 X Assembly Model Code* .05 b a y 1.44 RDFA-LAN-CJB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function A and B to T (High Capacity) SOLENOID VALVE 0 X P T B A Y .05 L Control 2.47 Max. Assembly Model Code* RPGC-LAN-CJX 3.62 .69 .69 Order Retainer and Seal Kits separately. (See page 141) L Control 2.47 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y Assembly Model Code* RDFA-LAN-CJX *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.44 Function SOLENOID VALVE A to B and B to A (Cross-port) 0 X P T B A Y .05 Assembly Model Code* RPEC-LAN-CJY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: L Control L Control 2.12 2.12 3.62 Max. Max. Order Retainer and Seal Kits separately. (See page 141) Assembly Model Code* RDDA-LAN-CJY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the differences in the European and U.S. seal plates. To order seal plates separately see page 141-142. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 174 US Selected Assemblies Catalogue #999-901-192 ISO 05 / CETOP 5 WITH X AND Y SEQUENCE VALVES T-2A Cavity X Y PILOT OPERATED x p t b All sandwich bodies shown below are 2.50” wide a DIRECT ACTING Gauge Port 1/4” NPTF y 2.44 Function In to P SOLENOID VALVE G P T B A Y .05 Assembly Model Code* RSFC-LAN-BJW *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b 0 a y 2.44 T B A Assembly Model Code* RSFC-LAN-BJ4 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a 0 Y y T B A CXED-XAN SOLENOID VALVE SEQUENCE INTO A .05 L Control 1.93 3.62 Max. .78 .62 Order Retainer and Seal Kits separately. (See page 141) 2.44 SOLENOID VALVE SEQUENCE INTO B CXED-XAN 0 X P SXEA-LAN-BJW *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function In to A (Reverse Free Flow Check) Out of B (Reverse Free Flow Check) Assembly Model Code* SXEA-LAN-BJ4 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function In to B (Reverse Free Flow Check) Out of A (Reverse Free Flow Check) SOLENOID VALVE SEQUENCE OUT A X P Assembly Model Code* L Control 3.62 2.06 Max. .19 Order Retainer and Seal Kits separately. (See page 141) SOLENOID VALVE SEQUENCE OUT B X Y .05 Assembly Model Code* RSFC-LAN-BJ5 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. L Control 1.93 3.62 Max. .62 .78 Order Retainer and Seal Kits separately. (See page 141) Assembly Model Code* SXEA-LAN-BJ5 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 20 for cartridge models RS*C-*** and SX*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the differences in the European and U.S. seal plates. To order seal plates separately see page 141-142. Go to www.sunhydraulics.com for more product information. US Selected Assemblies Catalogue #999-901-192 175 ISO 05/CETOP 5 with X and Y U.S. Sandwich Assemblies ISO 05/CETOP 5 with X and Y U.S. Sandwich Assemblies ISO 05 / CETOP 5 WITH X AND Y REDUCING VALVES T-2A Cavity Y PILOT OPERATED x t p b T P B A Function Gauge Port 1/4” NPTF y a 2.44 G X All sandwich bodies shown below are 2.50” wide X On P Drained to T SOLENOID VALVE Y 0 Assembly Model Code* .05 L Control 2.06 Max. .19 Order Retainer and Seal Kits separately. (See page 141) PBFB-LAN-BJP 3.62 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a Function Gauge Port 1/4” NPTF y 2.44 On A Drained to B SOLENOID VALVE G X P T B A Y 0 Assembly Model Code* PBFB-LAN-BJA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b .05 L Control 3.62 1.81 Max. Order Retainer and Seal Kits separately. (See page 141) Function Gauge Port 1/4” NPTF y a 2.44 On B Drained to A SOLENOID VALVE G X P T B Y A 0 Assembly Model Code* .05 L Control 2.06 Max. .19 Order Retainer and Seal Kits separately. (See page 141) 3.62 PBFB-LAN-BJB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y 2.44 Function SOLENOID VALVE On A Drain to T (Reverse Free Flow Check) CXFA X P T B A 0 Y .05 L Control 3.62 1.93 .78 .62 Max. Order Retainer and Seal Kits separately. (See page 141) Assembly Model Code* PBFB-LAN-BJ2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a Function 2.44 y SOLENOID VALVE CXFA X P T B A Y Assembly Model Code* PBFB-LAN-BJ3 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: On B Drain to T (Reverse Free Flow Check) 0 .05 L Control 3.62 1.93 .78 .62 Max. Order Retainer and Seal Kits separately. (See page 141) Page 34 for cartridge models PB*B-*** and page 102 for CX*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the differences in the European and U.S. seal plates. To order seal plates separately see page 141-142 Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 176 US Selected Assemblies Catalogue #999-901-192 ISO 05 / CETOP 5 WITH X AND Y REDUCING / RELIEVING VALVES T-2A Cavity Y PILOT OPERATED x p b t G X P B T A DIRECT ACTING Function On P Tank to T Drained to T Gauge Port 1/4” NPTF y a All sandwich bodies shown below are 2.50” wide X 2.44 SOLENOID VALVE Y 0 Assembly Model Code* .05 PPFB-LAN-BJP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a Assembly Model Code* L Control 2.06 Max. .19 Order Retainer and Seal Kits separately. (See page 141) 3.62 PRFB-LAN-BJP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function y Gauge Port 1/4” NPTF 2.44 On A Tank to B SOLENOID VALVE G X P T B A Y 0 Assembly Model Code* PPFB-LAN-BJA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a .05 L Control 3.62 1.81 Max. Order Retainer and Seal Kits separately. (See page 141) Assembly Model Code* PRFB-LAN-BJA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function y Gauge Port 1/4” NPTF On B Tank to A 2.44 SOLENOID VALVE G X P T B A Y 0 Assembly Model Code* .05 PPFB-LAN-BJB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a Assembly Model Code* L Control 2.06 Max. Order Retainer and Seal Kits separately. (See page 141) 3.62 y PRFB-LAN-BJB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 2.44 SOLENOID VALVE On A Tank to T (Reverse Free Flow Check) CXFA X P T B A Assembly Model Code* PPFB-LAN-BJ2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a 0 Y .05 L Control 3.62 1.93 .78 .62 Max. Order Retainer and Seal Kits separately. (See page 141) P T B A Y Assembly Model Code* PPFB-LAN-BJ3 PRFB-LAN-BJ2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function y 2.44 SOLENOID VALVE CXFA X Assembly Model Code* On B Tank to T (Reverse Free Flow Check) 0 .05 L Control 1.93 .62 .78 Max. Order Retainer and Seal Kits separately. (See page 141) 3.62 Assembly Model Code* PRFB-LAN-BJ3 *Add modifier /S to order Ductile Iron for pressure *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. rating over 3000 psi. NOTES: Page 34 for cartridge models PPFB-*** and PRFB-***, and page 102 for C*FA-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the differences in the European and U.S. seal plates. To order seal plates separately see page 141-142. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 177 ISO 05/CETOP 5 with X and Y U.S. Sandwich Assemblies ISO 05/CETOP 5 with X and Y U.S. Sandwich Assemblies ISO 05 / CETOP 5 WITH X AND Y COUNTERBALANCE VALVES T-2A Cavity All sandwich bodies shown below are 2.50” wide X PILOT RATIOS 3:1, 1.5:1 and 2:1 PILOT RATIOS 2.3:1, 4.5:1 and 10:1 Y Function x p t b a Gauge Port 1/4” NPTF y 2.44 On A Pilot from B SOLENOID VALVE G X P T B A Y 0 Assembly Model Code* Assembly Model Code* .05 L Control 1.38 3.62 Max. Order Retainer and Seal Kits separately. (See page 141) CBE*-LHN-BJA *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. CBE*-LJN-BJA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function x p t b Gauge Port 1/4” NPTF y a 2.44 On B Pilot from A SOLENOID VALVE G X P T B Y A 0 Assembly Model Code* .05 CBE*-LHN-BJB *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Assembly Model Code* L Control 1.63 3.62 Max. Order Retainer and Seal Kits separately. (See page 141) CBE*-LJN-BJB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function x p t b a y 2.44 On A and B (Cross-Piloted) SOLENOID VALVE X P T B A Y 0 Assembly Model Code* CBE*-LHN-BJY *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y .05 L Control L Control 1.65 3.62 1.65 .88 Max. .88 Max. Order Retainer and Seal Kits separately. (See page 141) X P T B A Y Assembly Model Code* CBE*-LHN-BJ8 *The 4th digit of the Model Code must be entered to specify counterbalance pilot ratio. Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. CBE*-LJN-BJY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 2.94 SOLENOID VALVE CXFC Assembly Model Code* CXFC Cushion Lock Circuit On A and B 0 .05 L Control 3.62 1.66 .95 Max. .95 Order Retainer and Seal Kits separately. (See page 141) L Control 1.66 Max. Assembly Model Code* CBE*-LJN-BJ8 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CBE*-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the differences in the European and U.S. seal plates. To order seal plates separately see page 141-142. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 178 US Selected Assemblies Catalogue #999-901-192 ISO 05 / CETOP 5 WITH X AND Y PILOT-TO-OPEN CHECK VALVES T-2A Cavity X Y PILOT OPERATED x p b t a All sandwich bodies shown below are 2.50” wide Gauge Port 1/4” NPTF y 2.44 Function On A Pilot from B SOLENOID VALVE G X P T B A Y 0 .05 Assembly Model Code* 3.62 .38 Max. X Control Order Retainer and Seal Kits separately. (See page 141) CKEB-XCN-BJA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p b t a Function Gauge Port 1/4” NPTF y 2.44 On B Pilot from A SOLENOID VALVE G X P B T Y A 0 .05 Assembly Model Code* 3.62 .63 Max. X Control Order Retainer and Seal Kits separately. (See page 141) CKEB-XCN-BJB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 2.44 x p t b a y X P T B A Y SOLENOID VALVE On A and B (Cross-Piloted) 0 .05 Assembly Model Code* CKEB-XCN-BJY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.62 .88 .65 .65 .88 Max. Max. X Control X Control Order Retainer and Seal Kits separately. (See page 141) NOTES: Page 78 for cartridge models CK**-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the differences in the European and U.S. seal plates. To order seal plates separately see page 141-142. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 179 ISO 05/CETOP 5 with X and Y U.S. Sandwich Assemblies ISO 05 / CETOP 5 WITH X AND Y CHECK VALVES T-5A Cavity X All sandwich bodies shown below are 2.50” wide Y CHECK VALVES Function 2.44 x p t b a y X P T B A Y SOLENOID VALVE On P 0 .05 3.62 Assembly Model Code* .378 Max. Order Retainer and Seal Kits separately. (See page 141) CXFA-XCN-DJP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y 2.44 SOLENOID VALVE B Function On A Free Flow Out of Valve On B Free Flow Into Valve 0 T B A Y .05 Assembly Model Code* CXFA-XCN-DJK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a 3.62 .658 .22 Max. Order Retainer and Seal Kits separately. (See page 141) 2.44 y 0 X P T B A SOLENOID VALVE A On A Free Flow Into Valve .05 Y 3.62 Assembly Model Code* .22 .658 Max. Order Retainer and Seal Kits separately. (See page 141) CXFA-XCN-DJJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 2.44 x Function On B Free Flow Out of Valve SOLENOID VALVE B X P SOLENOID VALVE A ISO 05/CETOP 5 with X and Y U.S. Sandwich Assemblies p t b a y X P T B A Y SOLENOID VALVE T to A and B 0 .05 Assembly Model Code* CXFA-XAN-DJW *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.62 .658 .50 .50 .658 Max. Max. Order Retainer and Seal Kits separately. (See page 141) NOTES: Page 102 for cartridge models CX*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the differences in the European and U.S. seal plates. To order seal plates separately see page 141-142. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 180 US Selected Assemblies Catalogue #999-901-192 ISO 05 / CETOP 5 WITH X AND Y FLOW CONTROL VALVES T-5A Cavity X p t b a y FULLY ADJUSTABLE PRESSURE COMPENSATED WITH FREE FLOW CHECK Y FULLY ADJUSTABLE NEEDLE x All sandwich bodies shown below are 2.50” wide Function 2.44 Meter-In P SOLENOID VALVE X P T B A Y Note: Free Flow Check with Model FDCB Only 0 .05 Assembly Model Code* NFDC-LAN-DJP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. FULLY ADJUSTABLE NEEDLE WITH FREE FLOW CHECK x p t b L Control 2.31 Max. Order Retainer and Seal Kits separately. (See page 141) Assembly Model Code* 3.62 a FDCB-LAN-DJP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 2.44 Meter-Out A SOLENOID VALVE y METER-OUT A Meter-In B METER-IN B X P T B A Y SOLENOID VALVE 0 .05 3.62 Assembly Model Code* L Control 2.41 Max. NCEB-LCN-DJA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a Assembly Model Code* .22 Order Retainer and Seal Kits separately. (See page 141) y FDCB-LAN-DJA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 2.44 SOLENOID VALVE Meter-In A METER-OUT B Meter-Out B METER-IN A T B A Y Assembly Model Code* NCEB-LCN-DJB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y SOLENOID VALVE 0 X P .05 Assembly Model Code* L Control 2.41 3.62 Max. .22 Order Retainer and Seal Kits separately. (See page 141) FDCB-LAN-DJB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 2.44 SOLENOID VALVE Meter-In A and B METER-OUT A-B Meter-Out A and B METER-IN A-B SOLENOID VALVE 0 XP T B A Y Assembly Model Code* NCEB-LCN-DJY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .05 L Control 2.41 Max. .44 3.62 .44 Order Retainer and Seal Kits separately. (See page 141) L Control 2.41 Max. Assembly Model Code* FDCB-LAN-DJY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 110 for cartridge models NF*C-*** and NC*B-***, and page 126 for FD**-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the differences in the European and U.S. seal plates. To order seal plates separately see page 141-142. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 181 ISO 05/CETOP 5 with X and Y U.S. Sandwich Assemblies ISO 05 / CETOP 5 WITH X AND Y FLOW CONTROL VALVES T-13A Cavity X Y FULLY ADJUSTABLE NEEDLE .50 t p b a t 0 Function Meter A to B and B to A SOLENOID VALVE A1 SOLENOID VALVE B1 ISO 05/CETOP 5 with X and Y U.S. Sandwich Assemblies 1.19 Mounting Holes: .28 diameter through hole. 4 places. 2.50 T P B A T T Assembly Model Code* T B A P .59 NFCC-LCN-DJS *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 3.62 1.81 0 Order Retainer and Seal Kits separately. (See page 141) NOTES: Page 110 for cartridge model NF*C-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the differences in the European and U.S. seal plates. To order seal plates separately see page 141-142. Go to www.sunhydraulics.com for more product information. 182 US Selected Assemblies Catalogue #999-901-192 ISO 07 / CETOP 7 RELIEF VALVES (SIDE PORTED SUBPLATE / SIDE PORTED SUBPLATE WITH GASKET MOUNTED TANK PORT) T-3A Cavity All subplates shown below are 5.0” wide X Y PILOT OPERATED DIRECT ACTING Function y p t a b x T Y P X G B A T Ports A, B, P, T Ports X, Y Assembly Model Code* 3/4” NPTF SAE-12 1/4” NPTF SAE-6 RPGC-LAN-ZLW RPGC-LAN-ZLX *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. X P P to T 1.94 1.28 0 3.78 2.03 .56 0 1/4” NPTF Gauge Port 0 0 T P .62 p t x 1.75 2.37 a b 2.74 y B A 4.00 5.00 3.65 1.90 .44 0 0 Ports A, B, P, T Ports X, Y Assembly Model Code* 3/4” NPTF SAE-12 1/4” NPTF SAE-6 RDFA-LAN-ZLW RDFA-LAN-ZLX *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function t a b X T P y T P X Y T Ports A, B, P, T Ports X, Y Assembly Model Code* 3/4” NPTF SAE-12 1/4” NPTF SAE-6 RPGC-LAN-VTE RPGC-LAN-VTF *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.00 3.78 2.03 .56 0 Gasket Mount 1/4” NPTF Gauge Port T Port 0 0 P T .63 0 T P 1.75 2.38 B A x B A 2.44 1.28 .94 0 y x p A 5.00 B 3.66 1.91 .44 4.00 P to T Ports A, B, P, T Ports X, Y Assembly Model Code* 3/4” NPTF SAE-12 1/4” NPTF SAE-6 RDFA-LAN-VTE RDFA-LAN-ZLF *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information and pricing. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 183 ISO 07/CETOP 7 Sandwich Assemblies ISO 07/CETOP 7 Sandwich Assemblies ISO 07 / CETOP 7 RELIEF VALVES T-3A / T-10A Cavities Y PILOT OPERATED x p t b a All sandwich bodies shown below are 3.50” wide X DIRECT ACTING Gauge Port 1/4” NPTF y Function P to T 1.88 0 G X P T B A .08 (4) – 118 O–rings Assembly Model Code* RPGC-LAN-CKP p b t a (2) – 111 O–rings Assembly Model Code* 4.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x .25 Y RDFA-LAN-CKP L Control 2.47 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. y Gauge Port 1/4” NPTF 1.88 Function A to T G 0 X P B T Y A .25 .08 (4) – 118 O–rings Assembly Model Code* RPGC-LAN-CKA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p x b t a 2.47 Max. .47 L Control (2) – 111 O–rings Assembly Model Code* 4.75 RDFA-LAN-CKA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. y Gauge Port 1/4” NPTF 1.88 Function B to T G 0 X P B T Y A .25 .08 (4) – 118 O–rings Assembly Model Code* RPGC-LAN-CKB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y X P T B A Y L Control 2.47 Max. Assembly Model Code* (2) – 111 O–rings RDFA-LAN-CKB 4.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function A and B to T (High Capacity) 2.66 0 Assembly Model Code* RPGC-LAN-CKX *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b .25 .08 (4) – 118 O–rings a y L Control 2.47 Max. .50 (2) – 111 O–rings 4.75 L Control 2.47 .50 Max. Assembly Model Code* RDFA-LAN-CKX *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 1.88 A to B and B to A (Cross-port) 0 .25 X P T B A Y Assembly Model Code* RPEC-LAN-CKY .08 (4) – 118 O–rings (2) – 111 O–rings 4.75 1.59 Max. L Control 1.59 Max. L Control Assembly Model Code* RDDA-LAN-CKY *Add modifier /S to order Ductile Iron for pressure *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. rating over 3000 psi. NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 184 US Selected Assemblies Catalogue #999-901-192 ISO 07/CETOP 7 Sandwich Assemblies ISO 07 / CETOP 7 SEQUENCE VALVES T-17A Cavity Y PILOT OPERATED x p t b Function Gauge Port 1/4” NPTF y a All sandwich bodies shown below are 3.50” wide X In to P 2.66 G X P T B A 0 Y .25 Assembly Model Code* .08 (4) – 118 O–rings (2) – 111 O–rings RSHC-LAN-BKW L Control 4.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a 2.37 .75 Max. Function In to A (Reverse Free Flow Check) y 2.66 CXGD-XCN X P T B A Y 0 .25 .08 (4) – 118 O–rings Assembly Model Code* RSHC-LAN-BK4 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a (2) – 111 O–rings L Control 2.37 Max. 1.41 4.75 .94 Function In to B (Reverse Free Flow Check) y 2.66 CXGD-XCN X P T B A Y 0 .25 .08 (4) – 118 O–rings Assembly Model Code* RSHC-LAN-BK5 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a L Control 2.37 Max. .16 (2) – 111 O–rings 4.75 1.09 .94 Function Out of A (Reverse Free Flow Check) y 2.66 CXGD-XCN X P T B A Y RSHC-LAN-BK6 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b .25 .08 (4) – 118 O–rings Assembly Model Code* x 0 a y (2) – 111 O–rings L Control 2.37 Max. 1.41 4.75 .94 Function Out of B (Reverse Free Flow Check) 2.66 CXGD-XCN 0 X P T B A .25 Y Assembly Model Code* RSHC-LAN-BK7 .08 (4) – 118 O–rings (2) – 111 O–rings L Control 4.75 .94 .16 1.09 2.37 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 20 for cartridge model RS*C-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 185 ISO 07/CETOP 7 Sandwich Assemblies ISO 07 / CETOP 7 REDUCING VALVES T-17A Cavity All sandwich bodies shown below are 3.50” wide X Y PILOT OPERATED x t p b a y G X T P B A Function Gauge Port 1/4” NPTF On P Drained to T 2.66 Y 0 .25 .08 Assembly Model Code* (4) – 118 O–rings (2) – 111 O–rings PBHB-LAN-BKP x p t b a y X P T B A Y L Control 2.37 Max. 4.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .75 Function 2.66 On A Drained to B 0 .25 .08 (4) – 118 O–rings Assembly Model Code* (2) – 111 O–rings L Control PBHB-LAN-BKA 2.37 .97 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y X P T B A Y 4.75 Function 2.66 On B Drained to A 0 .25 .08 (4) – 118 O–rings Assembly Model Code* PBHB-LAN-BKB (2) – 111 O–rings L Control 2.37 .91 Max. 4.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y Function 2.66 On A Drain to T (Reverse Free Flow Check) CXHA-XCN 0 X P T B A .08 (4) – 118 O–rings Assembly Model Code* *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b (2) – 111 O–rings L Control PBHB-LAN-BK2 x .25 Y a y 2.37 Max. 1.41 4.75 .78 Function 2.66 CXHA-XCN On B Drain to T (Reverse Free Flow Check) 0 X P T B A Assembly Model Code* PBHB-LAN-BKJ .25 Y .08 (4) – 118 O–rings (2) – 111 O–rings L Control 2.37 Max. .16 4.75 1.09 .94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 34 for cartridge model PB*B-*** and page 102 for CX*A-*** shows performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 186 US Selected Assemblies Catalogue #999-901-192 ISO 07 / CETOP 7 REDUCING / RELIEVING VALVES T-17A Cavity Y PILOT OPERATED x p b t a P B T A DIRECT ACTING Function On P Tank to T Drained to T Gauge Port 1/4” NPTF y G X All sandwich bodies shown below are 3.50” wide X 2.66 Y 0 .25 Assembly Model Code* .08 (4) – 118 O–rings (2) – 111 O–rings PPHB-LAN-BKP x p t b a y X P T B A Y L Control 3.02 .75 Max. 4.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Assembly Model Code* PRHB-LAN-BKP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function On A Tank to B Drained to B 2.66 0 Assembly Model Code* PPHB-LAN-BKA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x .25 .08 (4) – 118 O–rings p t b a y X P T B A Y L Control 3.02 Max. .97 (2) – 111 O–rings Assembly Model Code* PRHB-LAN-BKA 4.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function On B Tank to A Drained to A 2.66 0 .25 .08 (4) – 118 O–rings Assembly Model Code* PPHB-LAN-BKB (2) – 111 O–rings L Control 3.02 Max. .91 4.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a Assembly Model Code* PRHB-LAN-BKB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function On A Tank to T Drained to T (Reverse Free Flow Check) y 2.66 CXHA-XCN X P T B A Y PPHB-LAN-BK2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t b .25 .08 (4) – 118 O–rings Assembly Model Code* x 0 a y L Control 3.02 Max. 1.41 (2) – 111 O–rings Assembly Model Code* PRHB-LAN-BK2 4.75 .78 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function On B Tank to T Drained to T (Reverse Free Flow Check) 2.66 CXHA-XCN X P T B A Y Assembly Model Code* PPHB-LAN-BKJ 0 .25 .08 (4) – 118 O–rings (2) – 111 O–rings L Control 3.02 Max. .16 4.75 Assembly Model Code* PRHB-LAN-BKJ 1.09 .94 *Add modifier /S to order Ductile Iron for pressure *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. rating over 3000 psi. NOTES: Page 42 for cartridge models PP*B-*** and PR*B-***, and page 102 for CX*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 187 ISO 07/CETOP 7 Sandwich Assemblies ISO 07/CETOP 7 Sandwich Assemblies ISO 07 / CETOP 7 COUNTERBALANCE VALVES T-17A Cavity All sandwich bodies shown below are 3.50” wide X PILOT RATIOS 3:1, 2:1 and 1.5:1 PILOT RATIOS 2.3:1, 4.5:1 and 10:1 Y Function x p t b a y X P T B A Y On A Pilot from B 2.66 0 .25 .08 (4) – 118 O–rings Assembly Model Code* (2) – 111 O–rings Assembly Model Code* L Control CBG*-LHN-BKA 4.75 1.84 .97 Max. CBG*-LJN-BKA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function x p t b a y T B A Y On B Pilot from A 2.66 0 .25 X P .08 (4) – 118 O–rings Assembly Model Code* (2) – 111 O–rings CBG*-LHN-BKB .91 p t b a y X P T B A Y CBG*-LJN-BKB 1.84 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x Assembly Model Code* L Control 4.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 2.66 On A and B (Cross-piloted) 0 Assembly Model Code* CBG*-LHN-BKY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .25 .08 (4) – 118 O–rings (2) – 111 O–rings L Control L Control 1.84 1.44 Max. 4.75 1.37 1.84 Max. Assembly Model Code* CBG*-LJN-BKY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CB**-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 188 US Selected Assemblies Catalogue #999-901-192 ISO 07 / CETOP 7 PILOT-TO-OPEN CHECK VALVES T-17A Cavity All sandwich bodies shown below are 3.50” wide X Y PILOT OPERATED Function x p t b a y On A Pilot from B 2.66 X P T B A 0 Y .25 .08 (4) – 118 O–rings Assembly Model Code* (2) – 111 O–rings L Control: 2.37 Max. CKGB-XCN-BKA 4.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .97 Function x p t b a y X P T B A Y On B Pilot from A 2.66 0 .25 .08 (4) – 118 O–rings Assembly Model Code* (2) – 111 O–rings L Control: 2.37 Max. CKGB-XCN-BKB 4.75 .91 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function x p t b a y X P T B A Y On A and B (Cross-piloted) 2.66 0 Assembly Model Code* CKGB-XCN-BKY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .25 .08 (4) – 118 O–rings (2) – 111 O–rings 4.75 1.37 .90 Max. X Control .90 1.44 Max. X Control NOTES: Page 78 for cartridge model CK**-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 189 ISO 07/CETOP 7 Sandwich Assemblies ISO 07/CETOP 7 Sandwich Assemblies ISO 07 / CETOP 7 CHECK VALVES T-5A/T-16A Cavity All sandwich bodies shown below are 3.50” wide X Y CHECK VALVE Function x p t b a y X P T B A Y 2.66 On P 0 .25 .08 (4) – 118 O–rings Assembly Model Code* (2) – 111 O–rings 4.75 CXHA-XCN-DKP .47 .94 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y X P T B A Y Function On T Free Flow Out of Valve 2.66 0 .25 .08 (4) – 118 O–rings Assembly Model Code* CXHA-XCN-DKT .94 1.78 Max. (2) – 111 O–rings 4.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function t a p b x y T A P B X Y 1.88 T to A and B 0 .09 .08 (4) – 118 O–rings Assembly Model Code* (2) – 111 O–rings 3.50 CXFA-XAN-DKX .94 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y X P T B A Y Function On A and B, Free Flow Out of Valve 2.66 0 Assembly Model Code* CXHA-XCN-DKZ .25 .08 (4) – 118 O–rings (2) – 111 O–rings 4.75 .94 1.16 Max. 1.16 .94 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 102 for cartridge models CX*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 190 US Selected Assemblies Catalogue #999-901-192 ISO 07 / CETOP 7 FLOW CONTROL VALVES T-16A Cavity p t b a y FULLY ADJUSTABLE PRESSURE COMPENSATED WITH FREE FLOW CHECK Y FULLY ADJUSTABLE NEEDLE x All sandwich bodies shown below are 3.50” wide X Function 2.66 Meter-In P 0 X .25 P T B A Y Note: Free Flow Check on FDEA Only .08 (4) – 118 O–rings (2) – 111 O–rings Assembly Model Code* NFEC-LEN-DKP L Control 2.63 Max. .47 4.75 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. FULLY ADJUSTABLE NEEDLE WITH FREE FLOW CHECK Assembly Model Code* FDEA-LAN-DKP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 2.66 p x t b a Meter-Out A y 0 .25 X P T B A Y .08 (4) – 118 O–rings (2) – 111 O–rings L Control 2.63 Max. 1.16 Assembly Model Code* NCFB-L*N-DKA Assembly Model Code* 4.75 FDEA-LAN-DKA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 2.66 y Meter-Out B 0 X P T B A .25 Y .08 (4) – 118 O–rings (2) – 111 O–rings Assembly Model Code* NCFB-L*N-DKB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y X P T B A Y Assembly Model Code* L Control 2.63 1.09 Max. 4.75 FDEA-LAN-DKB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 2.66 Meter-Out A and B 0 .25 .08 (4) – 118 O–rings Assembly Model Code* (2) – 111 O–rings L Control 4.75 NCFB-L*N-DKY Max. 1.16 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y X P T B A Y L Control 2.63 1.09 Max. Assembly Model Code* FDEA-LAN-DKY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 2.66 Meter-In A and B 0 Assembly Model Code* NCFB-L*N-DKZ .25 .08 (4) – 118 O–rings (2) – 111 O–rings L Control 4.75 Max. 1.16 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: L Control 2.63 1.09 Max. Assembly Model Code* FDEA-LAN-DKZ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Page 110 for cartridge models NF*C-*** and NC*B-***, and page 126 for FD*A show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 191 ISO 07/CETOP 7 Sandwich Assemblies ISO 07/CETOP 7 Sandwich Assemblies ISO 07 / CETOP 7 CIRCUIT SAVER VALVES (PRESSURE COMPENSATOR / REGENERATIVE) T-13A Cavity/T-17A Cavity All sandwich bodies shown below are 3.50” wide X Y x p t b a y LPHC-XHN 2.66 Ext. X P T B A Assembly Model Code* External Shuttle Port YFFF: With Load Sensing Pressure Compensator (Restrictive) CSAB-*XN External Shuttle Port Y 0 .25 .08 (4) – 118 O–rings (2) – 111 O–rings YFFE-XHN-AB None 4.75 YFFF-XHN-AB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. .75 .91 Max. SAE-4 x p t b a Function YFFE: Pressure Compensator (Restrictive) Function Shuttle A and B (Output External) y 1.18 1/4” BSPP Port 0 X P T B A Y (4) – 118 O–rings Assembly Model Code* .25 (2) – 111 O–rings 4.75 .25 Max. CSAA-BXN-DKS *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function x p t b a y 2.66 B to A Regenerative CBGA-LHN COHA-XEN 0 X P T B A Y .25 .08 (4) – 118 O–rings Assembly Model Code* (2) – 111 O–rings L Control 4.75 YDFG-LHN-AB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.37 .91 .22 1.84 Max. Function x p t b a y X P T B A Y COHA-XEN 2.66 A to B Regenerative 0 Assembly Model Code* YDFE-LHN-AB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. CBGA-LHN .25 .08 (4) – 118 O–rings (2) – 111 O–rings L Control 1.84 1.44 Max. 4.75 .16 .91 NOTES: Page 50 for cartridge model CB*A-*** shows performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. 192 US Selected Assemblies Catalogue #999-901-192 ISO 08 / CETOP 8 RELIEF VALVES (SIDE PORTED SUBPLATE / REAR PORTED SUBPLATE / SIDE PORTED SUBPLATE WITH GASKET MOUNTED TANK PORT) T-3A Cavity All subplates shown below are 5.94” wide Y X PILOT OPERATED DIRECT ACTING Function x p t b a y G Y A B X P T P to T (Side Ports) 5.94 3.34 .47 t Ports A, B, P, T Ports X, Y Assembly Model Code* 1” NPTF SAE-16 1/4” NPTF SAE-6 RPGC-LAN-CSE RPGC-LAN-CSM L Control 1.64 5.94 p a x 0 Y y 1.81 1.12 .44 0 b X 4.38 2.50 Gauge Port 1/4” NPTF 4.50 4.06 .41 0 .91 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Ports A, B, P, T Ports X, Y Assembly Model Code* 1” NPTF SAE-16 1/4” NPTF SAE-6 RDFA-LAN-CSE RDFA-LAN-CSM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function x p t b a y 3.44 G t X P T B A p y Y 1.81 Ports X, Y Assembly Model Code* 1” NPTF SAE-16 1/4” NPTF SAE-6 RPGC-LAN-CRE RPGC-LAN-CRM 5.94 a x L Control 1.64 Ports A, B, P, T b .44 0 4.38 2.50 .41 0 .91 0 Rear Ports this Face *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p t y b a 2.38 .88 t Ports X, Y Assembly Model Code* 1” NPTF SAE-16 (T) 1” NPTF 1/4” NPTF SAE-6 RPGC-LAN-CTE RPGC-LAN-CTM Ports X, Y Assembly Model Code* 1” NPTF SAE-16 1/4” NPTF SAE-6 RDFA-LAN-CRE RDFA-LAN-CRM Function P to T (Gasket Mounted T and Y Port, Other Ports on Side) G X A B Ports A, B, P, T Ports A, B, P, T *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x P P to T (Rear Ports) Gauge Port 0 1/4” NPTF 4.50 4.06 L Control 1.64 5.94 x p a 0 Gauge Port 1/4” NPTF Y y b X 0 3.56 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.44 0 .91 Ports A, B, P, T Ports X, Y 1” NPTF SAE-16 (T) 1” NPTF 1/4” NPTF SAE-6 Assembly Model Code* RDFA-LAN-CTE RDFA-LAN-CTM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information and pricing. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 193 ISO 08/CETOP 8 Sandwich Assemblies ISO 08/CETOP 8 Sandwich Assemblies ISO 08 / CETOP 8 RELIEF VALVES T-16A Cavity X PILOT OPERATED x p t b a All sandwich bodies shown below are 4.50” wide Y DIRECT ACTING Function y Gauge Port 1/4” NPTF P to T (High Capacity) 3.44 G X P T B A Y 0 .25 (2) – 114 O–rings Assembly Model Code* RPIC-LAN-CDO *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p b t a P B T Function .25 (2) – 114 O–rings RPIC-LAN-CDC *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. p b t a P B T RDHA-LAN-CDC 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 RPIC-LAN-CDD p t b a y X P T B A Y Assembly Model Code* L Control 3.19 Max. b a y Assembly Model Code* RDHA-LAN-CDD 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function A and B to T (High Capacity) 3.44 0 .25 (2) – 114 O–rings L Control 3.22 Max. .53 RPIC-LAN-CDZ (4) – 121 O–rings (4) – 121 O–rings Assembly Model Code* L Control 3.22 Max. 1.47 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. t B to T (High Capacity) 3.44 .25 (2) – 114 O–rings *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p Assembly Model Code* Function Y A (4) – 121 O–rings Gauge Port 1/4” NPTF Assembly Model Code* x L Control 3.19 Max. y G X A to T (High Capacity) 3.44 0 Assembly Model Code* x *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Gauge Port 1/4” NPTF Y A RDHA-LAN-CDO 5.94 y G X L Control 3.19 Max. Assembly Model Code* (4) – 121 O–rings RDHA-LAN-CDZ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 3.44 A to B and B to A (High Capacity) (Cross-port) 0 X P T B .25 A Y (2) – 114 O–rings Assembly Model Code* RPIC-LAN-CDW L Control 3.22 Max. (4) – 121 O–rings 5.94 L Control 3.22 Max. Assembly Model Code* RDHA-LAN-CDW *Add modifier /S to order Ductile Iron for pressure *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. rating over 3000 psi. NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 194 US Selected Assemblies Catalogue #999-901-192 ISO 08/CETOP 8 Sandwich Assemblies ISO 08 / CETOP 8 SEQUENCE VALVES T-17A Cavity X PILOT OPERATED x p t b a All sandwich bodies shown below are 4.50” wide Y Gauge Port 1/4” NPTF y 3.44 Function In to P G X P T B A Y 0 .25 (2) – 114 O–rings Assembly Model Code* RSHC-LAN-HBW 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a 1.75 Max. y T B A Function In to A (Reverse Free Flow Check) Gauge Port 1/4” NPTF 3.44 G X P (4) – 121 O–rings L Control CXHA-XCN Y 0 .25 (2) – 114 O–rings Assembly Model Code* RSHC-LAN-HB4 (4) – 121 O–rings L Control 5.94 .94 .18 1.68 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a Function Out of A (Reverse Free Flow Check) Gauge Port 1/4” NPTF y 3.44 CXHA-XAN G X P T B A Y 0 .25 (2) – 114 O–rings Assembly Model Code* L Control RSHC-LAN-HB6 5.94 p t b a 1.78 Max. .94 .18 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x (4) – 121 O–rings y Function Out of B (Reverse Free Flow Check) Gauge Port 1/4” NPTF 3.44 G X P T B A Y Assembly Model Code* RSHC-LAN-HB7 CXHA-XCN 0 .25 (2) – 114 O–rings (4) – 121 O–rings L Control 5.94 .91 1.38 2.34 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Pages 20 for cartridge models RS*C-*** and page 102 for CX*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 195 ISO 08/CETOP 8 Sandwich Assemblies ISO 08 / CETOP 8 REDUCING VALVES T-19A Cavity/T-17A Cavity PILOT OPERATED x t p b a X y G X T P B A All sandwich bodies shown below are 4.50” wide Y Function On P Drained to T (High Capacity) Gauge Port 1/4” NPTF 3.44 Y 0 .25 (2) – 114 O–rings Assembly Model Code* PBJB-LAN-HBO (4) – 121 O–rings L Control 2.74 1.72 Max. 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a Function On A Drained to B (High Capacity) y 3.44 P X T B A Y 0 .25 (2) – 114 O–rings Assembly Model Code* PBJB-LAN-HBA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a L Control 2.74 Max. 1.72 (4) – 121 O–rings 5.94 Function On B Drained to A (High Capacity) y 3.44 X P T B A 0 .25 (2) – 114 O–rings Y Assembly Model Code* PBJB-LAN-HBB (4) – 121 O–rings 5.94 2.65 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a L Control 2.74 Max. Function Gauge Port 1/4” NPTF y On A Drain to T (Reverse Free Flow Check) 3.44 CXGD-XCN G X P T B A Y 0 .25 (2) – 114 O–rings Assembly Model Code* L Control PBHB-LAN-HBK 5.94 p t b a 2.47 Max. .91 .18 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x (4) – 121 O–rings Function Gauge Port 1/4” NPTF y On B Drain to T (Reverse Free Flow Check) 3.44 G X P T B A Assembly Model Code* PBHB-LAN-HBJ Y CXGD-XCN 0 .25 (2) – 114 O–rings (4) – 121 O–rings L Control .91 5.94 1.37 3.02 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 34 for cartridge model PBJB-*** and page 102 for CX*D-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 196 US Selected Assemblies Catalogue #999-901-192 ISO 08 / CETOP 8 REDUCING / RELIEVING VALVES T-19A Cavity/T-17A Cavity PILOT OPERATED x p b t a P B T y A DIRECT ACTING X Function On P Tank to T Drained to T (High Capacity) Gauge Port 1/4” NPTF 3.44 G X All sandwich bodies shown below are 4.50” wide Y Y 0 .25 (2) – 114 O–rings Assembly Model Code* PPJB-LAN-HBO (4) – 121 O–rings 5.94 1.72 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a L Control 3.69 Max. T B A 0 Y .25 (2) – 114 O–rings Assembly Model Code* PPJB-LAN-HBA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a (4) – 121 O–rings Assembly Model Code* L Control 3.69 Max. 1.72 PRJB-LAN-HBA 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function On B Tank to A Drained to A (High Capacity) y 3.44 X P T B A 0 .25 (2) – 114 O–rings Y Assembly Model Code* PPJB-LAN-HBB (4) – 121 O–rings 5.94 2.65 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a PRJB-LAN-HBO *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function On A Tank to B Drained to B (High Capacity) y 3.44 X P Assembly Model Code* L Control 3.69 Max. PRJB-LAN-HBB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function On A Tank to T Drained to T (Reverse Free Flow Check) Gauge Port 1/4” NPTF y Assembly Model Code* 3.44 CXGD-XCN G X P T B A Y 0 .25 (2) – 114 O–rings Assembly Model Code* L Control PPHB-LAN-HBK 5.94 .91 .18 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a (4) – 121 O–rings 2.47 Max. 3.44 G X P T B A Y Assembly Model Code* PPHB-LAN-HBJ PRHB-LAN-HBK *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function On B Tank to T Drained to T (Reverse Free Flow Check) Gauge Port 1/4” NPTF y Assembly Model Code* CXGD-XCN 0 .25 (2) – 114 O–rings (4) – 121 O–rings L Control .91 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.37 3.02 Max. Assembly Model Code* PRHB-LAN-HBJ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 42 for cartridge model PP*B-*** and PR*B-***, and page 102 for CX*D-*** shows performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 197 ISO 08/CETOP 8 Sandwich Assemblies ISO 08/CETOP 8 Sandwich Assemblies ISO 08 / CETOP 8 COUNTERBALANCE VALVES T-19A Cavity PILOT RATIOS 3:1, 1.5:1 and 2:1 x p t b a Y All sandwich bodies shown below are 4.50” wide PILOT RATIOS 2.3:1, 4.5:1 and 10:1 X Function On A Pilot from B (High Capacity) y 3.44 X P T B A 0 Y Assembly Model Code* .25 (2) – 114 O–rings L Control 2.31 Max. 1.72 CBI*-LHN-HBA (4) – 121 O–rings Assembly Model Code* 5.94 CBI*-LJN-HBA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function On B Pilot from A (High Capacity) y 3.44 X P T B A 0 Y .25 (2) – 114 O–rings Assembly Model Code* (4) – 121 O–rings 5.94 CBI*-LHN-HBB 2.65 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a Assembly Model Code* 2.31 Max. L Control Function y On A and B (Cross-Piloted) (High Capacity) 3.44 X P T B A Y Assembly Model Code* CBI*-LHN-HBY CBI*-LJN-HBB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .25 (2) – 114 O–rings L Control 2.31 Max. 1.72 (4) – 121 O–rings L Control 2.31 2.65 Max. 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Assembly Model Code* CBI*-LJN-HBY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CB**-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 198 US Selected Assemblies Catalogue #999-901-192 ISO 08 / CETOP 8 PILOT-TO-OPEN CHECK VALVES T-19A Cavity X PILOT OPERATED x p t b a All sandwich bodies shown below are 4.50” wide Y Function On A Pilot from B (High Capacity) y 3.44 X P T B A Y 0 .25 (2) – 114 O–rings Assembly Model Code* CKIB-XCN-HBA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y X P T B A Y (4) – 121 O–rings 5.94 1.12 1.72 Max. X Control Function On B Pilot from A (High Capacity) 3.44 0 .25 (2) – 114 O–rings Assembly Model Code* (4) – 121 O–rings 5.94 2.65 1.12 Max. X Control CKIB-XCN-HBB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function x p t b a y On A and B Cross-Piloted (High Capacity) 3.44 X P T B A Y Assembly Model Code* CKIB-XCN-HBY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .25 (2) – 114 O–rings 1.12 1.72 Max. X Control 5.94 (4) – 121 O–rings 2.65 1.12 Max. X Control NOTES: Page 78 for cartridge model CK**-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 199 ISO 08/CETOP 8 Sandwich Assemblies ISO 08/CETOP 8 Sandwich Assemblies ISO 08 / CETOP 8 CHECK VALVES T-18A Cavity/T-16A Cavity All sandwich bodies shown below are 4.50” wide Y X CHECK VALVE Function x p t b a y X P T B A Y 3.44 On P (High Capacity) 0 .25 (2) – 114 O–rings Assembly Model Code* (4) – 121 O–rings 5.94 1.19 1.16 Max. X Control CXJA-XCN-IBO *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function x p t b a y On T (High Capacity) 3.44 X P T B A Y 0 .25 (2) – 114 O–rings Assembly Model Code* CXJA-XCN-IBV *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. (4) – 121 O–rings 5.94 1.16 2.12 Max. X Control Function x p t b a y T to A and B 3.44 X P T B A Y 0 .25 (2) – 114 O–rings Assembly Model Code* CXHA-XAN-CDV *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b (4) – 121 O–rings 5.94 a 1.16 1.38 Max. X Control 1.16 Max. X Control Function On A and B Free Flow Out of Valve (High Capacity) y 3.44 X P T B A Y Assembly Model Code* CXJA-XCN-IBZ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .25 (2) – 114 O–rings (4) – 121 O–rings 5.94 2.12 2.16 1.19 Max. X Control 2.16 Max. X Control NOTES: Page 102 for cartridge model CX*A-*** shows performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. 200 US Selected Assemblies Catalogue #999-901-192 ISO 08 / CETOP 8 FLOW CONTROL VALVES T-18A Cavity All sandwich bodies shown below are 4.50” wide Y FULLY ADJUSTABLE NEEDLE FULLY ADJUSTABLE PRESSURE COMPENSATED WITH FREE FLOW CHECK X Function x p t b a y 3.44 Meter-In P (High Capacity) 0 X P T B A Y Note: Free Flow Check on FDFA Only .25 (2) – 114 O–rings Assembly Model Code* (4) – 121 O–rings L Control 3.28 1.19 Max. 5.94 NFFC-LGN-IBO *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. FULLY ADJUSTABLE NEEDLE WITH FREE FLOW CHECK p x a b t Assembly Model Code* FDFA-LAN-IBO *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Meter-Out A (High Capacity) y 3.44 P X A B T Y 0 .25 (2) – 114 O–rings Assembly Model Code* NCGB-LCN-IBE *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a L Control 3.28 Max. 1.19 (4) – 121 O–rings FDFA-LAN-IBE 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Meter-Out B (High Capacity) y 3.44 X P T B A Y 0 .25 (2) – 114 O–rings Assembly Model Code* (4) – 121 O–rings NCGB-LCN-IBF 5.94 2.12 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a L Control 3.28 Max. T B A Y NCGB-LCN-IBZ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y X P T B A Y FDFA-LAN-IBF *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .25 (2) – 114 O–rings Assembly Model Code* Assembly Model Code* Function Meter-In A and B (High Capacity) y 3.44 X P Assembly Model Code* L Control 3.28 Max. 1.19 5.94 (4) – 121 O–rings 2.12 L Control 3.28 Max. Assembly Model Code* FDFA-LAN-IBZ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Meter-Out A and B (High Capacity) 3.44 0 Assembly Model Code* NCGB-LCN-IBY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: .25 (2) – 114 O–rings L Control 3.28 Max. 1.19 5.94 (4) – 121 O–rings L Control 3.28 Max. 2.12 Assembly Model Code* FDFA-LAN-IBY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Page 110 for cartridge model NC*B-*** and page 126 for FD*A-*** show performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. Model Codes printed in red are Preferred Products and are readily available. US Selected Assemblies Catalogue #999-901-192 201 ISO 08/CETOP 8 Sandwich Assemblies ISO 08/CETOP 8 Sandwich Assemblies ISO 08 / CETOP 8 CIRCUIT SAVER VALVES (PRESSURE COMPENSATOR / LOAD SENSING / REGENERATIVE) T-13A Cavity/T-19A Cavity All sandwich bodies shown below are 4.50” wide Y X x p t b a y LPJC-XHN 3.44 External Shuttle Port Ext. X P T B A 0 .25 (4) – 121 O–rings YFIA-XHN-CA None p t b (2) – 114 O–rings 5.94 YFIB-XHN-CA *Add modifier /S to order Ductile Iron for pressure rating on YFIB over 3000 psi. Add /S for YFIA. 1.68 1.12 Max. .23 SAE-4 x YFIB: Pressure Compensator (Restrictive) with External Port CSAB-BXN Y Assembly Model Code* External Shuttle Port Function Shuttle A and B (Output External) y a 1.44 Ext. X P T B 1/4” NPTF Port in end of Cartridge 0 Y A Function YFIA: Pressure Compensator (Restrictive) 3.44 (4) – 121 O–rings (2) – 114 O–rings Assembly Model Code* 5.94 .19 Max. CSAA-BXN-IBS *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y X P T B A Y CBIA-LHN 3.44 Function B to A Regenerative (High Capacity) COJA-XEN 0 .25 (4) – 121 O–rings Assembly Model Code* 5.94 YDGF-LHN-CA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. x p t b a y X P T B A Y Assembly Model Code* YDGE-LHN-CA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.12 2.56 2.31 Max. L Control COJA–XEN 3.44 0 CBIA–LHN (2) – 114 O–rings .25 (4) – 121 O–rings 2.31 Max. 1.72 L Control Function A to B Regenerative (High Capacity) (2) – 114 O–rings 5.94 1.12 1.12 NOTES: Page 50 for cartridge model CB*A-*** shows performance curves, technical tips, and options. See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits. Go to www.sunhydraulics.com for more product information. 202 US Selected Assemblies Catalogue #999-901-192 Standard Assemblies Assembly Type Page CUSHION LOCK VALVES Dual Load Control Applications Two Cavity with Checks Two Cavity with Checks and Shuttle Two Cavity with Anti-Cavitations Checks Two Cavity with Anti-Cavitations Checks and Shuttle 205 207 209 211 HYDROSTATIC TRANSMISSION VALVES AND HOT OIL SHUTTLES Hot Oil Shuttle and Relief Applications Inline/1.00” SAE Flange Port Inline 1.50” SAE Flange Port 2.00” SAE Flange Port 214 215 216 217 Hydrostatic Transmission Applications Inline 1.00” SAE Flange Port 1.25” SAE Flange Port 1.50”/2.00” SAE Flange Port 218 219 220 221 LINE MOUNTED REGENERATIVE ASSEMBLIES Pressure Sensitive Applications 15 GPM Maximum Regenerative Flow 10 GPM Maximum Regenerative Flow 30 GPM Maximum Regenerative Flow 20 GPM Maximum Total Flow with Load Holding Check Valve 60 GPM Maximum Regenerative Flow 50 GPM Maximum Regenerative Flow 120 GPM Maximum Regenerative Flow 240 GPM Maximum Regenerative Flow DIRECT MOTOR MOUNTED ASSEMBLIES Char-Lynn S Series Motors Single/Dual Cross-port Relief and Single Counterbalance Applications Single/Dual Counterbalance and Dual Flow Control Applications Single Flow Control Applications Dual Cross-port Relief and Single Counterbalance Applications Single/Dual Counterbalance Applications Dual Cross-port Relief and Dual Counterbalance Applications Danfoss (OMP/OMR Series and OMT Series) Single/Dual Cross-port Relief and Single Counterbalance Applications Single/Dual Counterbalance Applications (Shuttles) Dual Flow Control Applications Single/Dual Cross-port Relief and Single Counterbalance Applications Single/Dual Counterbalance Applications (Shuttles) US Selected Assemblies Catalogue #999-901-192 203 224 224 225 225 226 226 227 227 229 230 231 232 233 234 235 237 238 239 240 241 242 CUSHION LOCK VALVES Standard Assemblies TECHNICAL PRODUCT INFORMATION CUSHION LOCK VALVES Applications The cushion lock circuit is used to control the acceleration, and deceleration of reciprocating or rotary reversing circuits. Most slewing type circuits have inertia loads and it is important that there is a facility to ensure that during operation there is good control of the motion. The cushion lock provides this type of control using counterbalance valves as both a relief for acceleration and providing a braking resistance during deceleration. Sun offers four basic types of cushion lock valves: 1. The basic dual counterbalance valve assembly with the check valves in supply lines and separate tank return line. 3. The assembly that incorporates the same features as version 1. but with additional anti-cavitation check valves from the external tank line to the service lines. C2 C1 T Tank V2 V1 4. The assembly as in version 3. but with a shuttle valve to release a springapplied mechanical brake. C2 C1 T C2 C1 Design Concepts and Features The use of counterbalance valves provides smooth control of the motion because the valves are modulating load control valves. The valves are also seated so provide good load locking capability, although on most motor applications a mechanical brake supplements this because there is always leakage across the motor. A wide range of pilot ratios and pressure ratings are available for the counterbalance valves to enable the most suitable valves to be selected for the application. The check valves used for anticavitation have low cracking pressure of 5 psi to create the least resistance. The valves are also available in ISO sandwiches or could be made in custom manifolds to suit a particular application. T Tank Tank V1 V2 Brake Shuttle 2. S V1 V2 The basic assembly as above but with a shuttle valve to release a springapplied mechanical brake. C2 C1 T Tank Brake Shuttle S V1 V2 204 US Selected Assemblies Catalogue #999-901-192 CUSHION LOCK VALVES Standard Assemblies: Cushion Lock Valves DUAL LOAD CONTROL APPLICATIONS (TWO CAVITY WITH CHECKS) PILOT RATIOS 1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1 C1 T 0-15 GPM C2 Cavity T-11A CXCD-XCN 2 places .72 V1 Ports C1, C2 V1, V2 3.00 V2 V1 V2 2.31 Assembly Model Code* Port T 3/8” NPTF 1/2” NPTF CBC*-L*N-EMB 1/2” NPTF 1/2” NPTF CBC*-L*N-EMC SAE-8 SAE-10 CBC*-L*N-EMJ SAE-10 SAE-10 CBC*-L*N-EMK L Control 1.28 Max. 1.12 C1 1.12 C2 T .38 0 3.00 2.12 1.50 .88 0 0 .38 0 1.50 3.12 3.50 0 .75 2.25 Mounting Holes: .34 diameter through hole 2 places. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. C1 T 0-30 GPM C2 Cavity T-2A CXED-XCN 2 places .66 3.75 V1 V2 V2 Ports C1, C2 V1, V2 Port T Assembly Model Code* 1/2” NPTF 3/4” NPTF CBE*-L*N-BMC 3/4” NPTF 3/4” NPTF CBE*-L*N-BMD SAE-10 SAE-12 CBE*-L*N-BMK SAE-12 SAE-12 CBE*-L*N-BML V1 2.87 L Control 1.57 Max. 1.25 1.25 C2 2.25 .75 .38 0 3.00 2.25 1.50 .75 0 0 .38 1.47 0 3.62 4.00 Mounting Holes: .42 diameter through hole 2 places. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. US Selected Assemblies Catalogue #999-901-192 C1 T 205 0 CUSHION LOCK VALVES Standard Assemblies: Cushion Lock Valves DUAL LOAD CONTROL APPLICATIONS (TWO CAVITY WITH CHECKS) PILOT RATIOS 1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1 C1 T 0-60 GPM C2 Cavity T-17A CXGD-XCN 2 places .94 0 5.25 V1 V2 V1 V2 Ports C1, C2 V1, V2 Port T Assembly Model Code* 1” NPTF 1 1/4” NPTF CBG*-L*N-HME 1 1/4” NPTF 1 1/4” NPTF CBG*-L*N-HMF SAE-16 SAE-20 CBG*-L*N-HMM SAE-20 SAE-20 CBG*-L*N-HMN 3.94 L Control 1.84 Max. 1.88 1.88 C1 C2 1.12 3.88 T .50 0 0 5.00 3.44 2.50 1.56 0 .50 0 1.81 4.50 5.00 Mounting Holes: .53 diameter through hole 2 places. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. C1 T 0-120 GPM C2 0 Cavity T-19A 4.34 1.53 6.00 0 1.72 V1 Ports C1, C2 V1, V2 Port T L Control 2.34 Max. Assembly Model Code* 1 1/2” SAE C61 1 3/8” NPTF YCJD-L*N-AR 1 1/2” SAE C61 1 3/8” NPTF YCJD-L*N-GR 1 1/2” SAE C61 1 3/8” NPTF YCJD-L*N-HR 0 0 C2 1.84 C1 5.75 3.80 V1 5.88 7.75 1.72 0 1.72 V2 3.80 V2 6.00 0 5.88 T 1.13 Max. 8.25 Model Code YCJD-L*N-AR YCJD-L*N-GR YCJD-L*N-HR 8.25 Pilot Ratio 3:1 4.5:1 10:1 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. 206 US Selected Assemblies Catalogue #999-901-192 CUSHION LOCK VALVES Standard Assemblies: Cushion Lock Valves DUAL LOAD CONTROL APPLICATIONS (TWO CAVITY WITH CHECKS AND SHUTTLE) PILOT RATIOS 1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1 0-15 GPM Cavity T-11A C1 T C2 CXCD-XCN 2 places .72 V1 S V2 3.00 V1 V2 Ports C1, C2 V1, V2 Port T Port S 3/8” NPTF 1/2” NPTF 1/4” NPTF CBC*-L*N-ENB 1/2” NPTF 1/2” NPTF 1/4” NPTF CBC*-L*N-ENC SAE-8 SAE-10 SAE-4 CBC*-L*N-ENJ SAE-10 SAE-10 SAE-4 CBC*-L*N-ENK 2.31 Assembly Model Code* L Control 1.28 Max. 1.12 C2 C1 1.12 T .38 0 3.00 2.12 1.50 .88 0 0 .38 0 1.50 3.12 3.50 0 2.25 .75 Mounting Holes: .34 diameter through hole 2 places. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-30 GPM Cavity T-2A C1 T C2 CXED-XCN 2 places .66 3.75 V1 S V2 V1 V2 Ports C1, C2 V1, V2 Port T Port S 1/2” NPTF 3/4” NPTF 1/4” NPTF CBE*-L*N-BNC 3/4” NPTF 3/4” NPTF 1/4” NPTF CBE*-L*N-BND SAE-10 SAE-12 SAE-4 CBE*-L*N-BNK SAE-12 SAE-12 SAE-4 CBE*-L*N-BNL 2.88 Assembly Model Code* 1.25 1.25 C1 C2 .75 1.50 2.25 3.00 T .38 0 3.00 2.25 1.50 .75 0 0 0 .38 1.47 3.62 4.00 Mounting Holes: .42 diameter through hole 2 places. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. US Selected Assemblies Catalogue #999-901-192 S 2.88 L Control 1.60 Max. 207 0 CUSHION LOCK VALVES Standard Assemblies: Cushion Lock Valves DUAL LOAD CONTROL APPLICATIONS (TWO CAVITY WITH CHECKS WITH SHUTTLE) PILOT RATIOS 1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1 0-60 GPM Cavity T-17A C1 T C2 CXGD-XCN 2 places .94 5.25 V1 S V2 V1 V2 Ports C1, C2 V1, V2 Port T Port S Assembly Model Code* 1” NPTF 1 1/4” NPTF 1/4” NPTF CBC*-L*N-HNE 1 1/4” NPTF 1 1/4” NPTF 1/4” NPTF CBC*-L*N-HNF SAE-16 SAE-20 SAE-4 CBC*-L*N-HNM SAE-20 SAE-20 SAE-4 CBC*-L*N-HNN 3.94 S 3.94 L Control 1.84 Max. 1.88 C1 1.88 C2 T .50 0 5.00 3.44 2.50 1.56 0 0 0 .50 1.81 0 4.50 1.12 2.50 3.88 1.72 0 Mounting Holes: .53 diameter through hole 2 places. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-120 GPM Cavity T-19A C1 T C2 0 1.53 4.34 6.00 0 Ports C1, C2 V1, V2 Port T 0 0 1.72 C2 1.84 C1 5.75 S V2 Port S 0 V2 1.72 V1 S 6.00 L Control 2.34 Max. 3.80 3.80 Assembly Model Code* 1 1/2” SAE C61 1 3/8” NPTF 1/4” NPTF YCJH-L*N-AR 1 1/2” SAE C61 1 3/8” NPTF 1/4” NPTF YCJH-L*N-GR 1 1/2” SAE C61 1 3/8” NPTF SAE-4 YCJH-L*N-HR V1 5.88 7.75 T 5.88 1.13 Max. 8.25 Model Code YCJH-L*N-AR YCJH-L*N-GR YCJH-L*N-HR 8.25 Pilot Ratio 3:1 4.5:1 10:1 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. 208 US Selected Assemblies Catalogue #999-901-192 CUSHION LOCK VALVES Standard Assemblies: Cushion Lock Valves DUAL LOAD CONTROL APPLICATIONS (TWO CAVITY WITH ANTI-CAVITATION CHECKS) PILOT RATIOS 1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1 C1 T 0-15 GPM C2 Cavity T-11A CXCD-XAN 2 places CXDA-XAN 2 places .72 V1 3.00 V2 V1 V2 Ports C1, C2 V1, V2 Port T Assembly Model Code* 3/8” NPTF 1/2” NPTF CBC*-L*N-EPB 1/2” NPTF 1/2” NPTF CBC*-L*N-EPC SAE-8 SAE-10 CBC*-L*N-EPJ SAE-10 SAE-10 CBC*-L*N-EPK L Control 1.28 Max. 2.31 1.12 1.12 C1 C2 .75 2.25 T .38 0 3.00 2.12 1.50 .88 0 0 .38 1.50 0 3.12 3.50 0 Mounting Holes: .34 diameter through hole 2 places. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. C1 T 0-30 GPM C2 Cavity T-2A CXFA-XAN 2 places CXED-XAN 2 places .66 3.75 V1 Ports C1, C2 V1, V2 V2 V2 Port T Assembly Model Code* 1/2” NPTF 1/2” NPTF CBE*-L*N-BPC 3/4” NPTF 3/4” NPTF CBE*-L*N-BPD SAE-10 SAE-12 CBE*-L*N-BPK SAE-12 SAE-12 CBE*-L*N-BPL V1 2.87 L Control 1.57 Max. 1.25 1.25 C2 2.25 .75 .38 0 3.00 2.25 1.50 .75 0 0 1.47 3.63 4.00 Mounting Holes: .42 diameter through hole 2 places. 0 .38 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. US Selected Assemblies Catalogue #999-901-192 C1 T 209 0 0 CUSHION LOCK VALVES Standard Assemblies: Cushion Lock Valves DUAL LOAD CONTROL APPLICATIONS (TWO CAVITY WITH ANTI-CAVITATION CHECKS) PILOT RATIOS 1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1 C1 T 0-60 GPM C2 Cavity T-17A CXGD-XAN 2 places CXHA-XAN 2 places .94 3.00 V1 V2 V1 V2 Ports C1, C2 V1, V2 Port T Assembly Model Code* 1” NPTF 1 1/4” NPTF CBG*-L*N-HPE 1 1/4” NPTF 1 1/4” NPTF CBG*-L*N-HPF SAE-16 SAE-20 CBG*-L*N-HPM SAE-20 SAE-20 CBG*-L*N-HPN 3.94 L Control 1.84 Max. 1.88 1.88 C1 C2 1.12 3.88 T .50 0 5.00 0 3.44 2.50 1.56 0 .50 1.81 0 4.50 5.00 0 Mounting Holes: .53 diameter through hole 2 places. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. C1 T 0-120 GPM C2 0 1.53 Cavity T-19A 4.34 6.00 Ports C1, C2 V1, V2 Port T V2 0 V2 1.72 V1 6.00 L Control 2.34 Max. 0 1.72 1 1/2” SAE C61 1 3/8” NPTF YCJE-L*N-AR 1 1/2” SAE C61 1 3/8” NPTF YCJE-L*N-GR 1 1/2” SAE C61 1 3/8” NPTF YCJE-L*N-HR V1 5.88 7.75 0 0 C2 1.84 C1 5.75 3.80 3.80 Assembly Model Code* 1.72 0 5.88 1.13 Max. T 8.25 Model Code YCJE-L*N-AR YCJE-L*N-GR YCJE-L*N-HR *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 8.25 Pilot Ratio 3:1 4.5:1 10:1 NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. 210 US Selected Assemblies Catalogue #999-901-192 CUSHION LOCK VALVES Standard Assemblies: Cushion Lock Valves DUAL LOAD CONTROL APPLICATIONS (TWO CAVITY WITH ANTI-CAVITATION CHECKS AND SHUTTLE) PILOT RATIOS 1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1 0-15 GPM C1 T C2 Cavity T-11A CXDA-XAN 2 places CXCD-XAN 2 places .72 3.00 V1 S V2 V2 Ports C1, C2 V1, V2 Port T Port S Assembly Model Code* 3/8” NPTF 1/2” NPTF 1/4” NPTF CBC*-L*N-EQB 1/2” NPTF 1/2” NPTF 1/4” NPTF CBC*-L*N-EQC SAE-8 SAE-10 SAE-4 CBC*-L*N-EQJ SAE-10 SAE-10 SAE-4 CBC*-L*N-EQK 2.31 L Control 1.28 Max. V1 S 2.31 1.12 1.12 C1 C2 T .38 0 3.00 2.12 1.50 .88 0 0 .38 1.50 0 3.12 3.50 0 .75 1.50 2.25 Mounting Holes: .34 diameter through hole 2 places. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-30 GPM C1 T C2 Cavity T-2A CXFA-XAN 2 places CXED-XAN 2 places .66 3.75 V1 S V2 Ports C1, C2 V1, V2 Port T Port S 2.88 Assembly Model Code* 1/2” NPTF 3/4” NPTF 1/4” NPTF CBE*-L*N-BQC 3/4” NPTF 3/4” NPTF 1/4” NPTF CBE*-L*N-BQD SAE-10 SAE-12 SAE-4 CBE*-L*N-BQK SAE-12 SAE-12 SAE-4 CBE*-L*N-BQL 2.88 L Control 1.60 Max. 1.25 1.25 0 3.00 2.25 1.50 .75 0 0 .38 1.47 .38 0 3.62 4.00 0 Mounting Holes: .42 diameter through hole 2 places. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult the Sun Factory for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. US Selected Assemblies Catalogue #999-901-192 211 S C1 C2 .75 1.50 2.25 3.00 CUSHION LOCK VALVES Standard Assemblies: Cushion Lock Valves DUAL LOAD CONTROL APPLICATIONS (TWO CAVITY WITH ANTI-CAVITATION CHECKS AND SHUTTLE) PILOT RATIOS 1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1 0-60 GPM C1 T C2 Cavity T-17A CXGD-XAN 2 places CXHA-XAN 2 places 0 .94 3.00 V1 S V2 V1 V2 Ports C1, C2 V1, V2 Port T Port S Assembly Model Code* 1” NPTF 1 1/4” NPTF 1/4” NPTF CBG*-L*N-HQE 1 1/4” NPTF 1 1/4” NPTF 1/4” NPTF CBG*-L*N-HQF SAE-16 SAE-20 SAE-4 CBG*-L*N-HQM SAE-20 SAE-20 SAE-4 CBG*-L*N-HQN 3.94 1.88 1.88 S C1 C2 .50 T 5.00 3.94 L Control 1.84 Max. 0 0 3.44 2.50 1.56 0 0 .50 1.81 4.50 5.00 0 1.12 2.50 3.88 Mounting Holes: .53 diameter through hole 2 places. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0-120 GPM C1 T C2 0 1.53 Cavity T-19A 4.34 6.00 L Control 2.34 Max. 0 Ports C1, C2 V1, V2 3.80 3.80 Port S Assembly Model Code* 1 1/2” SAE C61 1 3/8” NPTF 1/4” NPTF YCJG-L*N-AR 1 1/2” SAE C61 1 3/8” NPTF 1/4” NPTF YCJG-L*N-GR 1 1/2” SAE C61 1 3/8” NPTF SAE-4 YCJG-L*N-HR Port T V1 5.88 7.75 1.72 5.88 0 0 0 1.72 V2 1.72 V1 S V2 6.00 0 C2 1.84 C1 5.75 S 1.13 Max. T 8.25 Model Code YCJG-L*N-AR YCJG-L*N-GR YCJG-L*N-HR 8.25 Pilot Ratio 3:1 4.5:1 10:1 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. 212 US Selected Assemblies Catalogue #999-901-192 Standard Assemblies TECHNICAL PRODUCT INFORMATION HYDROSTATIC TRANSMISSION VALVES AND HOT OIL SHUTTLES Applications In all closed loop hydrostatic transmission circuits it is necessary to remove and replace some of the oil from the circuit to provide cooling and filtration. The normal rule of thumb is to continuously take out 10-15% of the pump flow. This is achieved using a hot oil shuttle valve with lowpressure relief. G3 G1 1 1 2 2 T G2 The hot oil shuttle valve senses pressure from the high-pressure side and opens to bleed off oil from the return low-pressure side of the circuit. A low-pressure charge pump into the inlet of the transmission pump makes up this oil. US Selected Assemblies Catalogue #999-901-192 2 1 G T 2 1 The oil passed through the hot oil shuttle valve goes across a lowpressure relief valve set at a slightly lower pressure than the charge pump. This oil is taken through an offline filtration and cooling unit before being returned to the oil reservoir. Often this oil is also passed through the casing drain of the transmission motor to help keep the motor cool. The other main requirement for close loop circuits is cross line relief valves to provide protection from over pressurization to the pump and motor. 213 Design Concepts and Features Sun offers a complete range of hot oil shuttle valves and hydrostatic transmission valves incorporating four through ports for easy installation into the circuit. The use of cartridge valves in these packages means an elimination of pipe work and provides easy maintenance. In the event of a problem, it simply means replacing a cartridge rather than the complete valve assembly. This reduces cost and eliminates down time. The cross line relief valves used are fast acting with limited overshoot to provide excellent protection from over pressurization. Sun can provide packages to handle transmission flows from 10 GPM right up to 240 GPM and pressures up to 5000 psi. As well as the standard packages shown in the catalogue, Sun can also design a custom package to suit the exact requirement for a customer’s application. HOT OIL SHUTTLE AND RELIEF APPLICATIONS (INLINE / 1.00” SAE FLANGE PORT BODIES) PILOT OPERATED 2 1 0-13 GPM G T Cavity T-10A DSCH-XHN Mounting Holes: (opposite side) .375-16 UNC-2B x.62 deep 1.08 SAE-6 Gauge Port 4.00 3.62 2 1 1 Ports 1 and 2 Port T Assembly Model Code* SAE-10 SAE-12 SAE-8 SAE-8 XRDC-LNN-AK XRDC-LNN-AL 1 RPEC-LNN 2.75 G T 2.16 1.84 2 2 .91 .38 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 2.44 2.12 3.50 2 1 0 0 1.11 2.75 P = psi 400 300 200 100 0 3 6 9 12 15 Flow = GPM 0-25 GPM G 1.12 Typical Hot Oil Relief/Shuttle Performance These Sun valve assemblies are for use in bleeding hot oil from the low pressure side of a hydrostatic transmission circuit. The hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. The hot oil is removed from the loop when the Sun RPEC cartridge is set below the hydrostatic charge pressure relief valve. Cavity T-10A DSEH-XHN T Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 2 places. SAE-6 Gauge Port 1.25 4.19 3.84 2 1 1 1 3.00 RPEC-LNN Ports 1 and 2 Port T Assembly Model Code* SAE-12 SAE-10 XRFC-LNN-AL T 1.94 1.97 1.91 G 2 2 .94 .34 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 4.00 2.66 2.25 These Sun valve assemblies are for use in bleeding hot oil from the low pressure side of a hydrostatic transmission circuit. The hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. The hot oil is removed from the loop when the Sun RPEC cartridge is set below the hydrostatic charge pressure relief valve. 1.38 0 0 1.09 3.00 Typical Hot Oil Relief/Shuttle Performance 500 P = psi HOT OIL SHUTTLE Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles 400 300 200 100 0 7.5 15 22.5 30 Flow = GPM NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. 214 US Selected Assemblies Catalogue #999-901-192 HOT OIL SHUTTLE Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles HOT OIL SHUTTLE AND RELIEF APPLICATIONS (INLINE BODIES) PILOT OPERATED 2 1 0-50 GPM G T Cavity T-3A DSGH-XHN Mounting Holes: (opposite side) .375-16 UNC-2B x.62 deep 1.56 SAE-6 Gauge Port 5.25 4.75 2 2 1 Ports 1 and 2 Port T Assembly Model Code* SAE-16 SAE-12 XRHC-LNN-AM RPGC-LNN 2 T 2.06 3.88 G 1 2.69 1 1.52 .50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 These Sun valve assemblies are for use in bleeding hot oil from the low pressure side of a hydrostatic transmission circuit. The hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. The hot oil is removed from the loop when the Sun RPGC cartridge is set below the hydrostatic charge pressure relief valve. 2 1 0-100 GPM G T 3.31 3.00 1.81 0 0 1.38 3.50 Typical Hot Oil Relief/Shuttle Performance 500 400 P = psi 4.50 300 200 100 15 0 30 45 60 Flow = GPM Cavity T-16A DSIH-XHN Mounting Holes: (opposite side) .375-16 UNC-2B x.62 deep SAE-6 Gauge Port 1.94 6.25 5.75 2 2 1 T RPIC-LNN Ports 1 and 2 Port T Assembly Model Code* SAE-20 SAE-16 XRJC-LNN-AM 2 2.38 4.72 G 1 3.17 1 1.69 .50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 6.00 0 2.44 0 Typical Hot Oil Relief/Shuttle Performance 500 P = psi These Sun valve assemblies are for use in bleeding hot oil from the low pressure side of a hydrostatic transmission circuit. The hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. The hot oil is removed from the loop when the Sun RPIC cartridge is set below the hydrostatic charge pressure relief valve. 4.56 4.00 400 300 200 100 0 30 60 90 Flow = GPM NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. US Selected Assemblies Catalogue #999-901-192 215 120 1.50 4.50 HOT OIL SHUTTLE AND RELIEF APPLICATIONS (1.50” SAE FLANGE PORT BODIES) PILOT OPERATED 2 1 0-100 GPM G Cavity T-16A DSIH-XHN T 1.62 SAE-6 Gauge Port 6.62 6.12 RPIC-LNN 2 2 2 Ports 1 and 2 Port T Assembly Model Code* 1 1/2”SAE C61 SAE-16 XRJC-LNN-AR T G *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1 .50 0 4.56 2.38 0 .47 0 6.00 2.25 Typical Hot Oil Relief/Shuttle Performance These Sun valve assemblies are for use in bleeding hot oil from the low pressure side of a hydrostatic transmission circuit. The hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. The hot oil is removed from the loop when the Sun RPIC cartridge is set below the hydrostatic charge pressure relief valve. 500 P = psi 400 300 200 100 60 30 0 0-100 GPM G 1.66 Mounting Holes: (opposite side) .375-16 UNC-2B x.62 deep 5.94 1 1.50” SAE Code 61 4-Bolt Flange Pattern 4 places. 3.31 1 2 4.97 2.38 1 90 Flow = GPM 120 Cavity T-16A DSIH-XHN T SAE-6 Gauge Port 1.12 7.75 7.25 2 RPIC-LNN 2.38 1 Ports 1 and 2 Port T Assembly Model Code* 1 1/2” SAE C62 SAE-16 XRJC-LNN-A6 2 2 T G 1.50” SAE Code 62 4-Bolt Flange Pattern 4 places. 3.88 1 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.84 1 1.91 Mounting Holes: (opposite side) .375-16 UNC-2B x.62 deep .50 0 6.94 5.56 3.38 .47 0 0 2.25 6.00 Typical Hot Oil Relief/Shuttle Performance These Sun valve assemblies are for use in bleeding hot oil from the low pressure side of a hydrostatic transmission circuit. The hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. The hot oil is removed from the loop when the Sun RPIC cartridge is set below the hydrostatic charge pressure relief valve. 500 P = psi HOT OIL SHUTTLE Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles 400 300 200 100 0 30 60 90 Flow = GPM 120 NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. 216 US Selected Assemblies Catalogue #999-901-192 HOT OIL SHUTTLE Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles HOT OIL SHUTTLE AND RELIEF APPLICATIONS (2.00” SAE FLANGE PORT BODY) PILOT OPERATED G3 0-100 GPM G1 1 Cavity T-16A 1 DSIH-XHN SAE-6 Gauge Ports 1.06 7.75 2 7.25 2 T G2 Ports 1 and 2 Port T Assembly Model Code* 2” SAE C61 SAE-16 XRJC-LNN-AS RPIC-LNN 2.38 2 2 G T Mounting Holes: (opposite side) .375-16 UNC-2B x.62 deep 5.81 2.00” SAE Code 61 4-Bolt Flange Pattern 4 places. 3.88 1 1 1.94 .50 0 These Sun valve assemblies are for use in bleeding hot oil from the low pressure side of a hydrostatic transmission circuit. The hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. The hot oil is removed from the loop when the Sun RPIC cartridge is set below the hydrostatic charge pressure relief valve. 4.56 2.38 .47 0 0 2.03 Typical Hot Oil Relief/Shuttle Performance 500 P = psi *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.94 400 300 200 100 0 30 60 90 Flow = GPM NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. US Selected Assemblies Catalogue #999-901-192 217 120 6.00 HYDROSTATIC TRANSMISSION APPLICATIONS (INLINE BODY) DIRECT ACTING G3 0-25 GPM G1 1 1 Cavity T-10A DSCH-XHN Mounting Holes: (opposite side) .375-16 UNC-2B x.62 deep .72 4.50 4.00 2 2 T 1 3.16 G2 Ports 1 and 2 Port T Ports G1, G2 & G3 Assembly Model Code* SAE-12 SAE-8 1/2” NPTF XRDB-LCN-AL 2 G2 G1 RDDA-LCN 2.25 Port 2 pressure control Both ends 2.34 G3 RDDA-LCN Port 1 pressure control T .94 1 .50 2 0 3.62 1.81 0 .84 0 3.16 4.00 1.94 RPEC-LNN *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. These Sun valve assemblies are for use with hydrostatic transmissions to provide overload relief valve protection for the main circuit in both directions. Additionally, an auxiliary shuttle valve allows bleeding of hot oil from the low pressure side. Hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. Hot oil is removed from the loop when the Sun RPEC cartridge is set below the hydrostatic charge pressure relief valve. NOTE: A mechanical brake is recommended to positively lock any static live load. Typical Hot Oil Relief/Shuttle Performance 400 P = psi HYDROSTATIC TRANSMISSION VALVES Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles 300 200 100 0 3 6 9 12 Flow = GPM 15 NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. 218 US Selected Assemblies Catalogue #999-901-192 HYDROSTATIC TRANSMISSION VALVES Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles HYDROSTATIC TRANSMISSION APPLICATIONS (1.00” SAE FLANGE PORT BODIES) DIRECT ACTING G3 0-50 GPM G1 1 1 Cavity T-3A RDFA-LCN Port 1 pressure control 3.59 2.38 DSEH-XHN .50 0 .91 4.78 4.39 G2 2 2 T RPEC-LNN 2 2 G3 T Ports 1 and 2 1” SAE C61 3.59 1.94 G2 Port T Ports G1, G2 & G3 Assembly Model Code* SAE-10 SAE-6 XRFB-LCN-AP Mounting Holes: (opposite side) .375-16 UNC-2B x.75 deep 1 2.39 1 1.19 .39 0 G1 .47 0 RDFA-LCN Port 2 pressure control 4.44 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. These Sun valve assemblies are for use with hydrostatic transmissions to provide overload relief valve protection for the main circuit in both directions. Additionally, an auxiliary shuttle valve allows bleeding of hot oil from the low pressure side. Hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. Hot oil is removed from the loop when the Sun RPEC cartridge is set below the hydrostatic charge pressure relief valve. NOTE: A mechanical brake is recommended to positively lock any static live load. G3 1 1 1.66 3.44 4.00 P = psi 400 300 200 100 7.5 0 15 22.5 30 Flow = GPM Cavity T-3A RDFA-LCN Port 1 pressure control 2.38 DSEH-XHN .50 .91 5.88 5.44 G2 2 0 Typical Hot Oil Relief/Shuttle Performance 500 0-50 GPM G1 1.00” SAE Code 61 4-Bolt Flange Pattern 4 places. 2 T RPEC-LNN 1.97 G2 2 2 T Ports 1 and 2 Port T Ports G1, G2 & G3 Assembly Model Code* 1” SAE C62 SAE-10 SAE-6 XRFB-LCN-A4 2.94 1 Mounting Holes: (opposite side) .438-14 UNC-2B x1.06 deep 1 4.94 4.09 1.00” SAE Code 62 4-Bolt Flange Pattern 4 places. 1.45 .44 0 G1 .47 0 RDFA-LCN Port 2 pressure control *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 400 300 200 100 0 7.5 15 219 22.5 Flow = GPM NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. US Selected Assemblies Catalogue #999-901-192 1.66 3.44 4.00 0 Typical Hot Oil Relief/Shuttle Performance 500 P = psi These Sun valve assemblies are for use with hydrostatic transmissions to provide overload relief valve protection for the main circuit in both directions. Additionally, an auxiliary shuttle valve allows bleeding of hot oil from the low pressure side. Hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. Hot oil is removed from the loop when the Sun RPEC cartridge is set below the hydrostatic charge pressure relief valve. NOTE: A mechanical brake is recommended to positively lock any static live load. 4.42 G3 30 HYDROSTATIC TRANSMISSION APPLICATIONS (1.25” SAE FLANGE PORT BODIES) DIRECT ACTING G3 0-100 GPM G1 1 Cavity T-16A RDHA-LCN Port 1 pressure control 1 DSGH-XHN 3.00 .44 0 .94 2 2 T G2 T Port T Ports G1, G2 & G3 Assembly Model Code* SAE-12 SAE-6 XRHB-LCN-AQ Mounting Holes: (opposite side) .375-16 UNC-2B x.75 deep 6.38 5.81 G2 RPGC-LNN 2 2.09 1 2 4.81 G3 3.19 1 1.56 G1 1.25” SAE Code 61 4-Bolt Flange Pattern 4 places. .56 0 4.94 3.94 .47 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1 P = psi 500 400 300 200 100 15 0 0-100 GPM G1 T Port T Assembly Model Code* DSGH-XHN 3.00 SAE-12 SAE-6 XRHB-LCN-A5 6.38 5.81 G2 T Mounting Holes: (opposite side) .375-16 UNC-2B x.75 deep 60 .44 0 RPGC-LNN 2 2.09 G2 Ports G1, G2 & G3 45 Cavity T-16A .94 2 30 Flow = GPM RDHA-LCN Port 1 pressure control 1 2 5.00 4.38 Typical Hot Oil Relief/Shuttle Performance These Sun valve assemblies are for use with hydrostatic transmissions to provide overload relief valve protection for the main circuit in both directions. Additionally, an auxiliary shuttle valve allows bleeding of hot oil from the low pressure side. Hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. Hot oil is removed from the loop when the Sun RPGC cartridge is set below the hydrostatic charge pressure relief valve. NOTE: A mechanical brake is recommended to positively lock any static live load. G3 0 RDHA-LCN Port 2 pressure control 1 G1 2 4.81 G3 3.19 1 1.56 1.25” SAE Code 62 4-Bolt Flange Pattern 4 places. .56 0 4.94 3.94 .47 0 0 4.38 5.00 RDHA-LCN Port 2 pressure control *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. These Sun valve assemblies are for use with hydrostatic transmissions to provide overload relief valve protection for the main circuit in both directions. Additionally, an auxiliary shuttle valve allows bleeding of hot oil from the low pressure side. Hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. Hot oil is removed from the loop when the Sun RPGC cartridge is set below the hydrostatic charge pressure relief valve. NOTE: A mechanical brake is recommended to positively lock any static live load. Typical Hot Oil Relief/Shuttle Performance 500 P = psi HYDROSTATIC TRANSMISSION VALVES Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles 400 300 200 100 0 15 30 45 Flow = GPM 60 NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. 220 US Selected Assemblies Catalogue #999-901-192 HYDROSTATIC TRANSMISSION VALVES Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles HYDROSTATIC TRANSMISSION APPLICATIONS (1.50” / 2.00” SAE FLANGE PORT BODIES) DIRECT ACTING G3 0-200 GPM G1 1 Cavity T-18A RDJA-LCN Port 1 pressure control 1 3.88 2.00 DSIH-XHN .69 7.75 2 2 T RPIC-LNN 2.41 G2 7.25 G2 2 T Ports 1 and 2 Port T Ports G1, G2 & G3 Assembly Model Code* 1 1/2” SAE C61 SAE-16 SAE-6 XRJB-LCN-AR Ports 1 and 2 2” SAE C61 SAE-6 XRJB-LCN-AS P = psi 200 100 0 30 120 Cavity T-18A RPIC-LNN 2.41 Mounting Holes: (opposite side) .375-16 UNC-2B x.88 deep 90 60 Flow = GPM 3.88 DSIH-XHN .69 0 8.19 7.72 G2 2 1 G1 2 6.19 G3 4.09 1 2.00 2.00” SAE Code 61 4-Bolt Flange Pattern 4 places. .47 0 6.94 5.69 .47 0 0 6.00 5.25 RDJA-LCN Port 2 pressure control *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Typical Hot Oil Relief/Shuttle Performance 500 400 P = psi These Sun valve assemblies are for use with hydrostatic transmissions to provide overload relief valve protection for the main circuit in both directions. Additionally, an auxiliary shuttle valve allows bleeding of hot oil from the low pressure side. Hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. Hot oil is removed from the loop when the Sun RPIC cartridge is set below the hydrostatic charge pressure relief valve. NOTE: A mechanical brake is recommended to positively lock any static live load. 300 200 100 0 30 60 221 90 Flow = GPM NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. US Selected Assemblies Catalogue #999-901-192 6.00 300 T Port T 2.25 400 G2 SAE-16 0 Typical Hot Oil Relief/Shuttle Performance RDJA-LCN Port 1 pressure control 2 Assembly Model Code* .50 500 0-200 GPM Ports G1, G2 & G3 1.88 .47 0 .78 T 1 1.50” SAE Code 61 4-Bolt Flange Pattern 4 places. RDJA-LCN Port 2 pressure control 1 2 3.88 0 These Sun valve assemblies are for use with hydrostatic transmissions to provide overload relief valve protection for the main circuit in both directions. Additionally, an auxiliary shuttle valve allows bleeding of hot oil from the low pressure side. Hot oil can be cooled, filtered, or used as a source of oil for flushing other pump and motor cases. Hot oil is removed from the loop when the Sun RPIC cartridge is set below the hydrostatic charge pressure relief valve. NOTE: A mechanical brake is recommended to positively lock any static live load. 1 G3 G1 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. G1 5.88 1 Mounting Holes: (opposite side) .375-16 UNC-2B x.88 deep 6.94 5.56 G3 2 120 Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles NOTES 222 US Selected Assemblies Catalogue #999-901-192 Standard Assemblies TECHNICAL PRODUCT INFORMATION LINE MOUNTED REGENERATIVE ASSEMBLIES It is important to remember to size pipe work correctly to allow for the increased flow going into the full bore side of the cylinder. US Selected Assemblies Catalogue #999-901-192 Full Bore Normal Operation Cylinder Annulus Oil from the pump fills the full bore of a cylinder. With a cylinder ratio of 2:1 and the annulus connected to tank the flow out of the annulus is half of the flow into the full bore. Regenerative Operation Full Bore The pressure sensitive regenerative circuit is used in many applications such as compacting machines. The first part of the cylinder extension occurs when there is very little load (for example during initial compaction) and regeneration provides a faster speed. When the load resistance increases, the pressure on the full bore side starts to increase and will pilot open a counterbalance valve connecting the rod side to tank and take the circuit out of regeneration. This then provides a slower speed, as it is now operating on the full bore area, but also a corresponding increase in force. Regenerative circuits do not affect the retraction of the cylinder. The illustration shows the appropriate calculations for regenerative circuits. Rod Sun offers two types of regenerative valve assemblies. One provides full time regeneration and the other is a pressure sensitive regenerative circuit. The full time regeneration has only a limited number of applications and is most commonly used for providing fast extension speeds with low force. The circuit Sun uses for all types of regeneration includes a pilot to close check valve connecting from the rod side to the full bore side. If this circuit is used in applications where the load can extend the cylinder it will be necessary to incorporate a vented load control valve on the rod side to prevent the load running away. Rod Applications Regenerative circuits are used to provide faster cylinder extension speeds by taking the oil from the rod end and diverting it to the head end of the cylinder. This means that the effective area during extension is only the rod area that gives a faster speed but also a reduced force. This means using a cylinder with a 2:1 area ratio between piston and rod, equal speeds and forces can be obtained in both directions without using a double rod. Rod Annulus Oil Pump Flow During regen, pump flow into the full bore end fills only the effective area of the rod. The area not filled by the pump flow is made up by the annulus oil feeding back into the full bore. Hence, the reason why during regen, the cylinder extends at a faster rate. 223 Design Concepts and Features The first main feature of all Sun regenerative packages is that they are installed after the directional valve controlling the actuator. This means that the higher flows generated are not passed through the directional valve, which can be the same size as for normal circuits. This also means that this package can more easily be added to an existing circuit with the minimum of disruption. The main feature for the pressure sensitive regenerative circuit is that Sun uses a counterbalance valve to transfer from regeneration to normal operation. This type of valve opens gradually as the pilot pressure increases and gives a much smoother transition compared to the more commonly used sequence valve. It therefore eliminates a great deal of the shock, which can occur during this transition. The assemblies can be supplied for various flow rates and packages such as line mounted, ISO sandwich assemblies and gasket-mounted subplates. It is also possible to mount the cartridges directly into the cylinder head. PRESSURE SENSITIVE REGENERATION APPLICATIONS REGENERATION 15 GPM Maximum Regenerative Flow CR CBCA-LHN CR 1.28 CODA-XEN .50 3.00 VR Ports CH, CR & VR Assembly Model Code* 1/2” NPTF SAE-10 YDCC-LHN-AC YDCC-LHN-AK Mounting Holes: .34 diameter through hole 2 places. CH VR 1.56 .50 CR 0 3.62 3.31 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.81 .31 0 0 .62 1.25 Pressure Drop 300 P = psi Regeneration diminishes progressively above setting of CBCA. NOTE: Refer to page 223 if load causes cylinder to extend. *For part number and price for body only contact your local Sun distributor. 200 CR to CH 100 VR to CR 3.75 0 7.5 11.25 15 Flow = GPM 10 GPM Maximum Regenerative Flow CR CH CKEB-LCN CBCA-LHN 2.09 VR Ports CH, CR & VR 1/2” NPTF SAE-10 CODA-XEN .50 CBCA-LHN 1.28 VH Assembly Model Code* YDCD-LHN-AC YDCD-LHN-AK Mounting Holes: .34 diameter through hole 2 places. VH VR CH CR 3.74 1.81 1.56 .50 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.12 4.81 .31 0 0 .75 1.50 Pressure Drop Includes CKEB load holding check valve. Regeneration diminishes progressively above setting of CBCA. NOTE: Refer to page 223 if load causes cylinder to extend. *For part number and price for body only contact your local Sun distributor. 300 P = psi REGENERATIVE Standard Assemblies: Line Mounted Regenerative Assemblies 200 CR to CH VR to CR 100 VH to CH 0 2.5 5 7.5 10 Flow = GPM NOTES: Page 50 for cartridge model CB**-*** and page 78 for CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. 224 US Selected Assemblies Catalogue #999-901-192 REGENERATIVE Standard Assemblies: Line Mounted Regenerative Assemblies PRESSURE SENSITIVE REGENERATION APPLICATIONS REGENERATION 30 GPM Maximum Regenerative Flow CR CBEA-LHN CH COFA-XEN 1.59 .59 3.25 CR Ports CH, CR & VR Assembly Model Code* 3/4” NPTF SAE-12 YDEC-LHN-AD YDEC-LHN-AL Mounting Holes: .42 diameter through hole 2 places. VR CH 1.75 CR .50 0 4.50 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.25 .50 0 0 .75 1.50 Pressure Drop 300 P = psi Regeneration diminishes progressively above setting of CBEA. NOTE: Refer to page 223 if load causes cylinder to extend. *For part number and price for body only contact your local Sun distributor. 200 CR to CH 100 VR to CR 0 7.5 15 22.5 30 Flow = GPM 20 GPM Maximum Total Flow with Load Holding Check Valve CR CH CKEB-LCN CBEA-LHN 2.03 1.60 .41 COFA-XEN VR Ports CH, CR & VR 3/4” NPTF SAE-12 3.25 VH Assembly Model Code* YDED-LHN-AD YDED-LHN-AL Mounting Holes: .42 diameter through hole 2 places. VR VH CH CR 4.50 2.25 1.75 .50 0 6.00 .50 0 5.50 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Pressure Drop Regeneration diminishes progressively above setting of CBEA. NOTE: Refer to page 223 if load causes cylinder to extend. *For part number and price for body only contact your local Sun distributor. P = psi 300 200 CR to CH VR to CR 100 VH to CH 0 5 10 15 20 Flow = GPM NOTES: Page 50 for cartridge model CB**-*** and page 78 for CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. US Selected Assemblies Catalogue #999-901-192 225 0 .75 1.50 PRESSURE SENSITIVE REGENERATION APPLICATIONS REGENERATION 60 GPM Maximum Regenerative Flow CR 1.00” SAE Code 61 4-Bolt Flange Pattern 2 places. 3.00 CH 3.00 1.50 1.50 0 VR 7.00 CBGA-LHN Ports CH, CR & VR Assembly Model Code* 3/4” NPTF 1” NPTF 1 1/4” NPTF SAE-12 SAE-16 YDGC-LHN-AD YDGC-LHN-AE YDGC-LHN-AF YDGC-LHN-AL YDGC-LHN-AM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 5.06 1.94 VR CH 0 0 7.00 4.00 .88 5.06 1.94 0 VR CH 3.94 .88 CBGA-LHN COHA-XEN COHA-XEN 1.81 .75 CR 6.00 1.81 3.50 1.00 0 .75 CR 0 0 6.00 3.50 Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 1.00 0 Pressure Drop Regeneration diminishes progressively above setting of CBGA. NOTE: Refer to page 223 if load causes cylinder to extend. *For part number and price for body only contact your local Sun distributor. P = psi 300 200 CR to CH VR to CR 100 15 0 30 45 60 Flow = GPM 50 GPM Maximum Regenerative Flow CR CH 1.25” SAE Code 61 4-Bolt Flange Pattern 2 places. 3.00 1.81 1.81 3.44 1.81 1.50 VR VH 1.69 0 0 0 1.12 1.91 3.62 5.34 6.12 7.25 0 Ports CH, CR & VR 3/4” NPTF 1” NPTF 1 1/4” NPTF SAE-12 SAE-16 Assembly Model Code* YDGD-LHN-AD YDGD-LHN-AE YDGD-LHN-AF YDGD-LHN-AL YDGD-LHN-AM *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.94 2.88 CBGA-LHN 5.00 VR 0 0 1.12 1.94 0 1.56 COHA-XEN .87 VH CH 2.34 CKGB-LCN Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 3.62 5.31 6.12 7.25 VR VH 2.22 CBGA-LHN CR COHA-XEN .87 CR CH 4.44 Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. 2.34 CKGB-LCN Pressure Drop 300 Regeneration diminishes progressively above setting of CBGA. NOTE: Refer to page 223 if load causes cylinder to extend. *For part number and price for body only contact your local Sun distributor. P = psi REGENERATIVE Standard Assemblies: Line Mounted Regenerative Assemblies 200 CR to CH 100 VH to CH 0 12.5 25 37.5 50 Flow = GPM NOTES: Page 50 for cartridge model CB**-*** and page 78 for CK*B-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. 226 US Selected Assemblies Catalogue #999-901-192 REGENERATIVE Standard Assemblies: Line Mounted Regenerative Assemblies PRESSURE SENSITIVE REGENERATION APPLICATIONS REGENERATION 120 GPM Maximum Regenerative Flow CR 2.53 0 6.47 1.22 3.50 CH VR 2.38 0 Ports CH, CR & VR Assembly Model Code* SAE 16 YDJC-LHN-AN 7.50 1.50 9.00 0 VR CBIA-LHN CH COJA-XEN CR 4.00 4.50 Mounting Holes: .53 diameter through hole. 2 Places. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Pressure Drop 300 P = psi Regeneration diminishes progressively above setting of CBIA. NOTE: Refer to page 223 if load causes cylinder to extend. *For part number and price for body only contact your local Sun distributor. 200 100 CR to CH VR to CR 0 30 60 90 Flow = GPM 120 240 GPM Maximum Regenerative Flow CR CH 2.00” SAE Code 61 4-Bolt Flange Pattern 3 places. 6.00 2.34 CBIA-LHN 2 places. VR Ports CH, CR, VR Assembly Model Code* 2” SAE C61 YDJC-LHN-AS 1.16 COJA-XEN 2 places. 3.00 0 0 .47 VR Mounting Holes: (opposite side) .375-16 UNC-2B x .62 deep. CH CR 5.94 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 .50 2.38 5.00 7.62 9.50 10.00 Pressure Drop P = psi 300 Regeneration diminishes progressively above setting of CBIA. NOTE: Refer to page 223 if load causes cylinder to extend. *For part number and price for body only contact your local Sun distributor. 200 100 CR to CH VR to CR 0 30 60 90 Flow = GPM NOTES: Page 50 for cartridge model CB**-*** shows performance curves, technical tips, and options. See page vii for technical information about line mount bodies including SAE flange pattern specifications. Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above. Go to www.sunhydraulics.com for more product information and pricing. US Selected Assemblies Catalogue #999-901-192 227 120 REGENERATIVE Standard Assemblies: Line Mounted Regenerative Assemblies NOTES 228 US Selected Assemblies Catalogue #999-901-192 TECHNICAL PRODUCT INFORMATION DIRECT MOTOR MOUNTED ASSEMBLIES Char-Lynn S Series Applications Applications The gerotor type gear motor is used on a large number of mobile and industrial applications. It is often necessary to incorporate valves in the circuit with the motor to control the flow and pressure. It may also be necessary to incorporate load control valves in the circuit. It is possible to mount line mounted valves into the pipework feeding the motor, but Sun offers a large range of valves that can be bolted directly onto the motor interface. This eliminates pipework and provides the control directly at the motor. The use of Sun cartridge valves in these assemblies means that in the event of a problem, it is a simple task to replace the cartridge rather than have to replace the complete valve. US Selected Assemblies Catalogue #999-901-192 On the smaller size motors the same gasket mounted face is used by at least four different manufacturers of this type of motor. The list below provides a quick cross-reference. Manufacturer (general motor type with gasket mounted interface) Eaton (S Type) White (RS 06 and RS 46) Parker/Ross/Nichols/Prince (TA, TB, TD, NE, 110A, 130S, 400S) On the specification in this catalogue for the smaller size of motor, we are using the Eaton reference number type as they are probably the largest manufacturer. For the larger size of motors we are only showing the Eaton reference of 2000 series and 4000 series. 229 Design Concepts and Features The valve assemblies shown for all sizes of motor are counterbalance valves and cross line relief valves. The counterbalance valves provide load holding and load control while the cross line relief valves provide over pressure protection. The Sun counterbalance valves provide excellent control with low hysteresis and minimum leakage. The relief valves are fast acting with minimum overshoot for excellent protection. On the smaller sizes of motor, Sun also offers flow control, which can accurately control the motor speed. The type of valve offered is a pressure compensated flow control valve but for more basic flow control a simple restrictor valve can also be used. Sun also has a further expanded range of bolt on valve assemblies. Consult the Sun factory or your local distributor for further information. DIRECT MOTOR MOUNT Standard Assemblies DIRECT MOTOR MOUNT Standard Assemblies: Direct Motor Mounted Assemblies: Char-Lynn S Series Motors SINGLE / DUAL CROSS-PORT RELIEF AND SINGLE COUNTERBALANCE APPLICATIONS T-10A / T-11A Cavities Go to www.sunhydraulics.com for more product information. MA MB DIRECT ACTING PILOT RATIO 3:1 Function Single Cross-Port Relief A to B 2 L Control 2.33 Max. 1 2.94 MA MB 1.91 2 Ports 1, 2 Assembly Model Code* SAE 10 RDDA-L*N-ZFK 1 .72 MA MB 1.35 3.15 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2 4.50 Function Single Cross-Port Relief B to A L Control 2.33 Max. 1 2.94 MA MB Assembly Model Code* SAE 10 RDDA-L*N-ZFK 1 .72 MA MB 1.35 3.15 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. A 1.91 2 Ports 1, 2 4.50 Function B Dual Cross-Port Relief L Control 2.36 Max. 3.00 MA MB A 2.25 Ports A, B Assembly Model Code* SAE 8 RDDA-L*N-YXB MA MB B 0.75 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 1.38 3.50 L Control 2.36 Max. Function 3.00 2.40 VB Single Counterbalance on A VB VA 0.81 MA L Control 1.28 Max. MB VA MA MB 0.25 0 0 0.25 0.81 1.38 2.31 3.69 VA L Control 1.28 Max. VA MB CBCA-LAN-ZPD *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. MA MB MA SAE 10 Single Counterbalance on B VB 0.81 Assembly Model Code* Function 3.00 2.40 VB Ports VA, VB 0.25 0 0 0.25 0.81 1.38 2.31 Ports VA, VB Assembly Model Code* SAE 10 CBCA-LAN-ZPB 3.69 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 2 for cartridge model RD*A-*** and page 50 for CB**-*** show performance curves, technical tips, and options. See page 229 for technical information about bolt-on packages. 230 US Selected Assemblies Catalogue #999-901-192 SINGLE / DUAL COUNTERBALANCE AND DUAL FLOW CONTROL APPLICATIONS T-11A / T-13A Cavities Go to www.sunhydraulics.com for more product information. MA MB FULLY ADJUSTABLE PRESSURE COMPENSATED WITH FREE FLOW CHECK PILOT RATIO 3:1 L Control 3.75 1.28 Max. 0 2.38 Single Counterbalance on A with Shuttle 0 VB VA Function VA S .62 MB SAE-4 Shuttle Port MA VB X Control .72 MB S SAE 10 CBCA-LAN-ZDV *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 0 2.38 Single Counterbalance on B with Shuttle 0 X Control .72 VB Assembly Model Code* 2.38 3.00 3.75 VA MA Ports VA, VB VA .62 MB SAE-4 Shuttle Port VB MA MA 2.38 MB 3.00 L Control 1.28 Max. 0 Assembly Model Code* SAE 10 CBCA-LAN-ZDY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 3.68 2.31 Ports VA, VB Dual Counterbalance 0 VA VB VB 0.63 MA L Control 1.28 Max. MB VA 2.37 MA MB Assembly Model Code* SAE 10 CBCA-LAN-YTA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.00 2.38 L Control 0 1.28 Max. VB VA Ports VA, VB Function Dual Counterbalance with Shuttle 3.75 VA .62 MB S SAE-4 Shuttle Port Ports VA, VB Assembly Model Code* SAE 10 CBCA-LAN-XTS MA VB MA 2.38 MB 3.00 X Control .72 VA *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function VB 0 2.38 3.44 0 VA Dual Flow Control Meter-out on A and B 0.59 MB L Control 2.21 Max. MA MB Ports VA, VB Assembly Model Code* SAE 10 FDBA-LAN-XWT MA VB 2.41 3.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 126 for cartridge model FD**-*** and page 50 for CB**-*** show performance curves, technical tips, and options. See page 229 for technical information about bolt-on packages. US Selected Assemblies Catalogue #999-901-192 231 DIRECT MOTOR MOUNT Standard Assemblies: Direct Motor Mounted Assemblies: Char-Lynn S Series Motors DIRECT MOTOR MOUNT Standard Assemblies: Direct Motor Mounted: Char-Lynn S Series Motor SINGLE FLOW CONTROL APPLICATIONS T-13A Cavity Go to www.sunhydraulics.com for more product information. MA MB FULLY ADJUSTABLE VA Function Single Flow Control Bleed-Off VB Mounting Hole: .50 diameter through hole. 0.25 0.60 0 2.75 2.40 0.62 0 0.25 MA 0.81 MA MB 1.38 MA MB Ports VA, VB Assembly Model Code* SAE 10 NFCC-LCN-ZFZ *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.06 VA VB .75 2.25 L Control 1.06 Max. VA NOTES: Page 110 for cartridge model NF**-*** show performance curves, technical tips, and options. See page 229 for technical information about bolt-on packages. 232 US Selected Assemblies Catalogue #999-901-192 DUAL CROSS-PORT RELIEF AND SINGLE COUNTERBALANCE APPLICATIONS T-10A / T-2A Cavities Go to www.sunhydraulics.com for more product information. MA MB DIRECT ACTING PILOT RATIO 3:1 2.75 Function 0 0.75 Dual Cross-Port Relief VA 1.28 VB VB MA VA 0.66 MB 0 Mounting Hole: .41 diameter through hole. 0 MA MB 0.47 Ports VA, VB Assembly Model Code* SAE 10 RDDA-L*N-YWA 1.97 L Control 2.25 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 3.00 3.50 3.03 1.34 0.47 0 Function Single Counterbalance on A 0 VA 0.94 0 2.38 1.28 2.78 3.50 0 VB 0.47 L Control 1.57 Max. VB MB 0.94 1.34 MA 2.56 VA 3.03 CBEA-LAN -117 0-Ring (x2) Mounting Holes: .41 diameter through holes, .59 diameter x .38 deep. 3 places. MB MA Ports VA, VB Assembly Model Code* SAE 12 CBEA-LAN-ZPG *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Single Counterbalance on B 0 VA 0.94 0 2.38 VB 1.28 CBEA-LAN 0.47 0.94 VB MB 2.78 3.50 0 1.34 MA L Control 1.57 Max. VA 2.56 3.03 -117 0-Ring (x2) MB MA 0 S VA Mounting Holes: .41 diameter through holes, .59 diameter x .38 deep. 3 places. 0.94 0 0.44 2.38 VB 1.28 2.78 3.50 0 Ports VA, VB Assembly Model Code* SAE 12 CBEA-LAN-ZPI *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Single Counterbalance on A with Shuttle 0.47 MB L Control 1.57 Max. VB 0.94 1.34 1.75 S MA 2.56 VA 3.03 Ports VA, VB Assembly Model Code* SAE 12 CBEA-LAN-ZPM CBEA-LAN Mounting Holes: .41 diameter through holes, .59 diameter x .38 deep. 3 places. -117 0-Ring (x2) MA MB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 2 for cartridge model RD*A-*** and page 50 for CB**-*** show performance curves, technical tips, and options. See page 229 for technical information about bolt-on packages. US Selected Assemblies Catalogue #999-901-192 233 DIRECT MOTOR MOUNT Standard Assemblies: Direct Motor Mounted: Char-Lynn 2000 Series Motors DIRECT MOTOR MOUNT Standard Assemblies: Direct Motor Mounted: Char-Lynn 2000 Series Motors SINGLE / DUAL COUNTERBALANCE APPLICATIONS T-2A Cavity Go to www.sunhydraulics.com for more product information. MA MB PILOT RATIO 3:1 0 0.94 0 0.44 2.38 1.28 L Control 1.57 S VA 2.78 3.50 0 0.47 VB 0.94 VB MB Function Single Counterbalance on B with Shuttle 1.34 1.75 S CBEA-LAN MA 2.56 VA Ports VA, VB Assembly Model Code* SAE 12 CBEA-LAN-ZPO 3.03 MB MA Mounting Holes: .41 diameter through holes, .59 diameter x .38 deep. 3 places. -117 0-Ring (x2) 0 .094 0 2.38 1.28 L Control 1.57 Max. VA 2.78 3.50 0 Function Dual Counterbalance 0.47 VB MB *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0.94 VB 1.34 MA 2.56 VA 3.03 CBEA-LAN (x2) MB MA 0 .094 0 0.44 2.88 L Control 1.57 Max. S VA Mounting Holes: .41 diameter through holes, .59 diameter x .38 deep. 3 places. -117 0-Ring (x2) 1.28 2.78 3.50 0 Assembly Model Code* SAE 12 CBEA-LAN-YTC *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Dual Counterbalance with Shuttle 0.47 VB MB Ports VA, VB VB 1.34 1.75 S MA VA MA MB -117 0-Ring (x2) CBEA-LAN (x2) 0.31 CSAD 3.03 Mounting Holes: .41 diameter through holes, .59 diameter x .38 deep. 3 places. Ports VA, VB Assembly Model Code* SAE 12 CBEA-LAN-XYS *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CB**-*** show performance curves, technical tips, and options. See page 229 for technical information about bolt-on packages. 234 US Selected Assemblies Catalogue #999-901-192 DUAL CROSS-PORT RELIEF AND DUAL COUNTERBALANCE APPLICATIONS T-10A / T-2A Cavities A Go to www.sunhydraulics.com for more product information. B DIRECT ACTING PILOT RATIOS 3:1 Function Dual Cross-Port Relief 0.92 3.08 3.52 2.65 0.48 0 1.35 0 0 0.31 1.25 2.19 2.50 .75 diameter through holes, 2 places. Mounting Holes: 40 diameter through holes, 8 places. 1.94 RDDA-L*N RDDA-L*N Assembly Model Code* RDDA-L*N-YVP L Control 2.26 Max. 0 -214 O-Ring 4.00 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Mounting Holes: .40 diameter through hole, 7 places. Tapped holes x .87 deep. M10 x 1.5-6H, 4 places. 3.00 Function Dual Counterbalance on A and B 1.50 L Control 1.57 Max. 0 5.21 1.20 0 .75 SAE Code-61 4-bolt flange pattern, 4 places. 1.94 Ports 3/4” SAE C61 Assembly Model Code* CBEA-LAN-VZX/M CBEA Add modifier /T to order Ductile Iron for pressure rating over 3000 psi. 0 4.33 6.50 0 2.17 -214 O-Ring, 2 places. Mounting Holes: .40 diameter through hole, 7 places. Tapped holes x .87 deep. M10 x 1.5-6H, 4 places. 3.00 Function Dual Counterbalance on A and B with Shuttle 1.50 L Control 1.57 Max. 5.21 0 0.75 CSAA 1.20 0 .75 SAE Code-61 4-bolt flange pattern, 4 places. 2.43 Ports 3/4” SAE C61 Assembly Model Code* CBEA-LAN-VWZ CBEA 0.56 0 6.50 4.33 3.34 Shuttle valve CSAA-BXN external port .25-19 BSPP port 2.17 0 *Add modifier /T to order Ductile Iron for pressure rating over 3000 psi. -214 O-Ring, 2 places. NOTES: Page 2 for cartridge model RD*A-*** and page 50 for CB**-*** show performance curves, technical tips, and options. See page 229 for technical information about bolt-on packages. US Selected Assemblies Catalogue #999-901-192 235 DIRECT MOTOR MOUNT Standard Assemblies: Direct Motor Mounted: Char-Lynn 4000 Series Motors DIRECT MOTOR MOUNT Standard Assemblies: Direct Motor Mounted NOTES 236 US Selected Assemblies Catalogue #999-901-192 TECHNICAL PRODUCT INFORMATION DIRECT MOTOR MOUNTED ASSEMBLIES Danfoss (OMP/OMR Series and OMT Series) Applications The Danfoss gerotor type gear motor is used on a large number of mobile and industrial applications. It is often necessary to incorporate valves in the circuit with the motor to control the flow and pressure. It is also sometimes necessary to incorporate load control valves in the circuit. The use of Sun cartridge valves in these valve assemblies means that in the event of a problem it is a simple task to replace the cartridge rather than have to replace the complete valve. We are showing a range of bolt-on valve assemblies for the two most common ranges of Danfoss motors, the OMP/ OMR range and the OMT range. It is possible to mount line-mounted valves into the pipework feeding the motor but Sun offers a large range of valves that can be bolted directly onto the motor interface. This eliminates pipework and provides the control directly at the motor. US Selected Assemblies Catalogue #999-901-192 Design Concepts and Features The valve assemblies shown for all sizes of motor are counterbalance valves and cross line relief valves. The counterbalance valves provide load holding and load control while the cross line relief valves provide protection from over pressurisation. The Sun counterbalance valves provide excellent control with low hysteresis and minimum leakage. The relief valves are fast acting with minimum overshoot for excellent protection. On the smaller sizes of motor, Sun also offers flow control, which can accurately control the motor speed. The type of valve offered is a restrictor type control valve but for more accurate flow control a pressure compensated valve can also be used. Sun also has a further expanded range of bolt on valve assemblies. Consult your local Sun company or distributor for further information. 237 DIRECT MOTOR MOUNT Standard Assemblies DIRECT MOTOR MOUNT Standard Assemblies: Direct Motor Mounted: Danfoss (OMP/OMR Series) SINGLE / DUAL CROSS-PORT RELIEF AND SINGLE COUNTERBALANCE APPLICATIONS T-10A / T-11A Cavities Go to www.sunhydraulics.com for more product information. A B DIRECT ACTING PILOT RATIO 3:1 Function Single Cross-Port Relief A to B V2 V1 0 0.81 1.38 2.23 2.80 3.50 1.94 0.56 0 0 0.38 G A 1.17 1.80 1.95 B L Control 2.12 Max. 2.58 Ports V1, V2 Guage Port SAE10 SAE-6 Assembly Model Code* RDDA-L*N-WVY 3.37 3.75 V1 A V2 B G Mounting Holes: .34 diameter through holes, .53 diameter x .38 deep. 4 places. -118 0-Ring (x2) *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Single Cross-Port Relief B to A V2 V1 Mounting Holes: .34 diameter through holes, .53 diameter x .38 deep. 4 places. 3.75 3.37 1.94 G B V2 1.17 Guage Port Assembly Model Code* SAE10 SAE-6 RDDA-L*N-WVS A L Control 2.12 Max. 1.95 1.80 Ports V1, V2 0 V1 2.58 A 0.56 G B 0.38 0 0 0.81 1.38 2.23 2.80 3.50 -118 0-Ring (x2) *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function V2 V1 0.81 1.38 0 2.23 2.80 3.50 L Control 2.31 Max. 0 0.38 G1 G2 A 1.17 B 1.80 Guage Port Assembly Model Code* SAE10 SAE-6 RDDA-L*N-WVP L Control 2.12 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. V1 A V2 B 1.95 2.58 Ports V1, V2 Dual Cross-Port Relief 0.56 0 1.94 G1 3.37 3.75 G2 Mounting Holes: .34 diameter through holes, .53 diameter x .38 deep. 4 places. -118 0-Ring (x2) Function V1 V2 V2 0 V1 0.91 2.44 0 0 0.79 L Control 0.50 1.16 Max. V2 B A 2.86 1.14 1.92 2.08 V2 3.06 3.50 4.00 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Single Counterbalance on A V1 0.95 A B 2.21 3.00 0 Mounting Holes: .34 diameter through holes, .53 diameter x .38 deep. 4 places. -118 0-Ring (x2) Ports V1, V2 Assembly Model Code* SAE10 CBCA-LAN-WZH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function V2 -118 0-Ring (x2) V1 V2 0 0.79 2.21 3.00 Single Counterbalance on B 0 V1 V1 1.14 0.50 V1 0.95 A L Control 1.92 2.08 B A B V2 1.16 Max. 0 0 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: 0.91 2.44 3.06 3.50 4.00 Mounting Holes: .34 diameter through holes, .53 diameter x .38 deep. 4 places. Ports V1, V2 Assembly Model Code* SAE10 CBCA-LAN-WZE *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Page 2 for cartridge models RD*A-*** and page 50 for CB**-*** show performance curves, technical tips, and options. See page 229 for technical information about bolt-on packages. 238 US Selected Assemblies Catalogue #999-901-192 SINGLE / DUAL COUNTERBALANCE APPLICATIONS (SHUTTLES) T-11A Cavity Go to www.sunhydraulics.com for more product information. A B PILOT RATIO 3:1 -118 0-Ring (x2) 0 0.56 0.91 0 2.44 20,1 35,6 56,1 76,2 0 L Control V1 V2 V2 V1 0.50 1.16 Max. V2 B A 1.14 1.92 2.08 S B V1 0.95 A V2 3.06 3.50 0.39 Port ‘S’ SAE-4 in cartridge hex. 0 0.56 Mounting Holes: .34 diameter through holes, .53 diameter x .38 deep. 4 places. 2.44 0.91 0 0.79 0.50 V2 1.40 2.21 3.00 0 L Control V1 Ports V1, V2 Assembly Model Code* SAE10 CBCA-LAN-WZS 4.00 -118 0-Ring (x2) V2 Function Single Counterbalance on A with Shuttle A V1 0.95 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Single Counterbalance on B with Shuttle V1 2.86 B A 1.92 2.08 1.16 Max. B V2 V1 0.39 3.06 3.50 0 Mounting Holes: .34 diameter through holes, .53 diameter x .38 deep. 4 places. 0 2.44 0.91 L Control V2 V1 0.79 Function 2.21 3.00 Dual Counterbalance V2 V2 3.06 3.50 4.00 B A Mounting Holes: .34 diameter through holes, .53 diameter x .38 deep. 4 places. -118 0-Ring (x2) 0.91 0 2.44 L Control S V1 V2 V1 1.16 Max. B 2.86 V2 V2 3.06 3.50 Port ‘S’ SAE-4 in cartridge hex. A 0 0.56 Mounting Holes: .34 diameter through holes, .53 diameter x .38 deep. 4 places. 0.91 V2 A 0.65 B 2.86 SAE10 CBCA-LAN-WZV 0.39 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Shuttle Only V1 1.14 V2 V2 4.00 Port ‘S’ Mounting Holes: SAE-4 .34 diameter through holes, in cartridge hex. .53 diameter x .38 deep. 4 places. 239 Ports V1, V2 Assembly Model Code* SAE10 CSAA-BXN-WZY 3.06 3.50 NOTES: Page 50 for cartridge models CB**-*** show performance curves, technical tips, and options. See page 229 for technical information about bolt-on packages. US Selected Assemblies Catalogue #999-901-192 Assembly Model Code* 0.79 1.40 2.21 3.00 1.92 2.08 S A Ports V1, V2 0 V1 B *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function 0 2.44 0.50 V1 CBCA-LAN-WZL 1.14 1.92 2.08 -118 0-Ring (x2) V2 SAE10 4.00 0.39 B Assembly Model Code* V1 0.95 A 0.79 1.40 2.21 3.00 0 0.50 V2 Ports V1, V2 Function Dual Counterbalance with Shuttle -118 0-Ring (x2) 0 0.56 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 1.92 2.08 1.16 Max. 2.86 CBCA-LAN-WZP V1 0.95 B SAE10 0 0.50 A V1 V2 Assembly Model Code* 4.00 Port ‘S’ SAE-4 in cartridge hex. 0 Ports V1, V2 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. DIRECT MOTOR MOUNT Standard Assemblies: Direct Motor Mounted: Danfoss (OMP/OMR Series) DUAL FLOW CONTROL APPLICATIONS T-5A Cavity Go to www.sunhydraulics.com for more product information. A B FULLY ADJUSTABLE PRESSURE COMPENSATED FLOW CONTROL WITH REVERSE FREE FLOW CHECK Function V1 V2 2.21 0.91 0.79 2.09 3.00 L Control 2.29 Max. 0 2.00 0 0.50 0.69 V2 A V1 1.92 B Dual Flow Control Meter-in on A and B 0.62 0 0 2.08 A B 3.31 3.50 L Control 2.31 Max. Mounting Holes: .34 diameter through holes, .53 diameter x .38 deep. 4 places. 4.00 Ports V1, V2 Assembly Model Code* SAE10 FDCB-LAN-WZB -118 0-Ring (x2) *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function V1 V2 0.91 0 0 0.79 2.21 2.09 3.00 Dual Flow Control Meter-out on A and B L Control 2.29 Max 2.00 0.50 0.69 2.08 B 0 0 DIRECT MOTOR MOUNT Standard Assemblies: Direct Motor Mounted: Danfoss (OMP/OMR Series) A 1.92 B A 3.31 3.50 L Control 2.31 Max. 4.00 Mounting Holes: .34 diameter through holes, .53 diameter x .38 deep. 4 places. -118 0-Ring (x2) Ports V1, V2 Assembly Model Code* SAE10 FDCB-LAN-WXH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 126 for cartridge models FD*B-*** show performance curves, technical tips, and options. See page 229 for technical information about bolt-on packages. 240 US Selected Assemblies Catalogue #999-901-192 SINGLE / DUAL CROSS-PORT RELIEF AND SINGLE COUNTERBALANCE APPLICATIONS T-10A / T-2A Cavities Go to www.sunhydraulics.com for more product information. B A DIRECT ACTING PILOT RATIO 3:1 V2 0 0 -123 0-Ring (x2) 1.40 1.32 1.81 0.97 0.91 B V1 1.94 V2 V1 0.42 4.00 3.64 2.94 1.21 1.94 2.06 0 0.36 0 Function Single Cross-Port Relief A to B A 2.31 A B Ports V1, V2 Assembly Model Code* SAE 12 RDDA-L*N-WLV 3.50 Mounting Holes: .42 diameter through holes, 4 places. L Control 2.19 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.94 1.21 1.94 2.06 0 0.36 0 0 -123 0-Ring (x2) 0.91 1.32 V2 0.97 Function Single Cross-Port Relief B to A 0 B V1 1.94 V2 V1 0.42 4.00 3.64 1.40 1.81 A 2.31 A B Ports V1, V2 Assembly Model Code* SAE 12 RDDA-L*N-WMV 3.50 Mounting Holes: .42 diameter through holes, 4 places. L Control 2.19 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 0.36 0 V1 0.97 0 0 -123 0-Ring (x2) 0.91 B 1.32 V1 1.94 3.64 V2 V1 0.42 Function Dual Cross-Port Relief 4.00 2.94 1.21 1.94 2.06 1.40 1.81 A 2.31 A B Ports V1, V2 Assembly Model Code* SAE 12 RDDA-L*N-WLY L Control 2.19 Max. Mounting Holes: .42 diameter through holes, 4 places. L Control 2.19 Max. *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 2.75 1.44 0 0 V2 V1 0.72 0 1.62 Function Single Counterbalance on A 2.60 1.69 3.00 0 0.36 1.00 V1 A 1.95 2.07 L Control 1.66 Max. B 3.00 V2 4.00 3.64 B A Mounting Holes: .42 diameter through holes, .69 diameter x .35 deep. 4 places. -123 0-Ring (x2) 2.75 1.44 0 0 0 V2 V1 1.00 0 0.36 L Control 1.66 Max. A 0.72 1.62 Ports V1, V2 Assembly Model Code* SAE 12 CBEA-LAN-WKH *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function Single Counterbalance on B 2.60 1.69 3.00 2.07 V1 1.95 4.00 B 3.00 V2 3.64 B A -123 0-Ring (x2) Mounting Holes: .42 diameter through holes, .69 diameter x .35 deep. 4 places. Ports V1, V2 Assembly Model Code* SAE 12 CBEA-LAN-WKL *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Pages 2 for cartridge models RD*A-*** and page 50 for CB**-*** show performance curves, technical tips, and options. See page 229 for technical information about bolt-on packages. US Selected Assemblies Catalogue #999-901-192 241 DIRECT MOTOR MOUNT Standard Assemblies: Direct Motor Mounted: Danfoss (OMT Series) DIRECT MOTOR MOUNT Standard Assemblies: Direct Motor Mounted: Danfoss (OMT Series) SINGLE / DUAL COUNTERBALANCE APPLICATIONS (SHUTTLES) T-2A Cavity Go to www.sunhydraulics.com for more product information. B A PILOT RATIO 3:1 Function V2 -123 0-Ring (x2) V1 2.75 1.44 0 0 S 0.72 0 0.36 0 1.00 V1 A 1.65 B B A Single Counterbalance on A with Shuttle 2.60 1.69 3.00 1.62 2.07 L Control 1.66 Max. 3.00 V2 3.64 4.00 Port ‘S’ SAE-4 in cartridge hex. 0.69 Mounting Holes: .42 diameter through holes, .69 diameter x .35 deep. 4 places. Ports V1, V2 Assembly Model Code* SAE 12 CBEA-LAN-WKP *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function V2 V1 -123 0-Ring (x2) 2.75 S 0 0 0.72 1.62 Single Counterbalance on B with Shuttle 2.60 1.69 3.00 0 0.36 0 1.00 V1 A 1.95 B 2.07 B A 3.00 V2 3.64 L Control 4.00 1.66 Max. Mounting Holes: .42 diameter through holes, .69 diameter x .35 deep. 4 places. Port ‘S’ SAE-4 in cartridge hex. Ports V1, V2 Assembly Model Code* SAE 12 CBEA-LAN-WKS 0.69 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. Function V2 V1 -123 0-Ring (x2) 2.75 1.44 0.72 0 0 0 0.36 0 1.00 V1 A 1.95 B A Dual Counterbalance 2.60 1.69 3.00 1.62 2.07 B 3.00 V2 3.64 L Control 4.00 1.66 Max. Mounting Holes: .42 diameter through holes, .69 diameter x .35 deep. 4 places. V2 V1 2.75 1.44 0 0 0.72 1.62 1.00 CBEA-LAN-WKV 66,0 42,9 3.00 V1 A 1.95 A SAE 12 *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. 0 0.36 0 B Assembly Model Code* Function Dual Counterbalance with Shuttle S -123 0-Ring (x2) Ports V1, V2 2.07 B 3.00 3.64 L Control 42,2 Max. Port ‘S’ SAE-4 in cartridge hex. V2 4.00 0.69 Mounting Holes: .42 diameter through holes, .69 diameter x .35 deep. 4 places. Ports V1, V2 Assembly Model Code* SAE 12 CBEA-LAN-WKY *Add modifier /S to order Ductile Iron for pressure rating over 3000 psi. NOTES: Page 50 for cartridge model CB**-*** show performance curves, technical tips, and options. See page 229 for technical information about bolt-on packages. 242 US Selected Assemblies Catalogue #999-901-192 General Information Page Cartridge Control Options 244 Cartridge Control Kits 245 4 Cavity Plugs 246 3 2 1 Solenoid Electrical Connector Options 248 Pressure Drop Data Chart 249 Cartridge Cavities and Cavity Tools 250 US Selected Assemblies Catalogue #999-901-192 243 General Information CARTRIDGE CONTROL OPTIONS General Purpose Controls L Standard Screw Adjustment O-ring seal on adjust screw. Adjust screw positively retained. Overset protection-pilot spring cannot go solid. Key Lock Kit Optional adjustment Key Lock Cover Kit for L controls allows adjustment to be locked with a key to prevent unauthorized changes in valve setting. Adjustment easily accessible when lock assembly is removed. 2.44" Requires replacement of 1.66" standard locknut with special locknut which accepts assembly, and new wire 3.12" stop ring for overset to remove key or cover protection. 5/32” Hex 9/16” Hex K Handknob with Lock Knob Handknob and lock knob added to L control. Sun handknob kits for field conversion are available. See cartridge control kits. 5/32” Hex O Handknob with Panel Mount Special threaded cartridge hex body with panel nut for mounting cartridge through access hole in control panel. Handknob and lock knob included. 1.25” diameter Zero Indicator Panel Hole Panel Hole: Series 1 cartridges Series 2 cartridges 1.17” diameter H Calibrated Handknob with Detent Lock Fully calibrated handknob for flow control cartridges. 40 radial calibrations per turn. Moveable zero indicator. (Minor disassembly required.) Rising detented locking collar positively locks adjustment knob against vibration or accidental tampering. Any desired setting may be recorded and repeated. U.S. Patent #4,577,831 5/32” Hex .75” dia. 1.00” dia. .09” .30” Dia. Locking Collar Rising Stem Counts Full Turns C Tamper Resistant Factory Set Diameter 1.13” Dia. 1.38” Dia. 1.62” Dia. 1.62” Dia. Steel cover press-fits onto L control cartridge shoulder. Valves may be ordered in this configuration. Specify pressure setting on order. Setting stamped on cartridge hex. Kits for field conversion are available. See cartridge control kits. Series 1 2 3 4 NCCB NCEB NCFB NCGB NCCC NCEC NCFC NCGC NFCC NFDC NFEC NFFC NFCD NFDD NFED NFFD FDBA FDCB FDEA FDFA Special Purpose Controls (for use in systems where adjustment is seldom changed after installation) 5/32” Hex J Socket Head Set Screw with Cap Stem seal O-ring under locknut. Adjustment screw is not retained. No overset protection. F Wrench Adjustment Stem seal O-ring under locknut. Adjusting screw is not retained. Overset protection-pilot spring cannot go solid. 9/16” Hex Counterbalance Valves Series 1, 2, 3: 5/32" Hex Series 4: 7/32" Hex L Standard Leakproof Screw Adjustment. O-ring seal on adjust screw. All Sun counterbalance cartridges are built with a leakproof adjustment (O-ring seals on the adjusting screw) but are not designed for frequent adjustment in the field. Cartridges that are factory pre-set by Sun to a customer specified pressure setting are available and can be installed directly on a machine without the need for further adjustment. Series 1, 2, 3: 9/16" Hex Series 4: 3/4" Hex C Tamper Resistant Factory Set See C Control description above. 244 US Selected Assemblies Catalogue #999-901-192 General Information CARTRIDGE CONTROL KITS Service Kit Number Description Adjustment Screw Kit 991-006 Use specifically with Control/Cartridge Description Locknut All F controls Adjust Screw Seal Seal Cap Adjustment Screw Kit 991-010 All J controls Tamper Resistant Cover 991-000 991-004 991-001 991-002 991-003 For all Sun cartridges with L adjustment Series 0 - 3/4” (19,0 mm) hex hex Series 1 - 7/8” (22,2 mm) hex Series 2 - 1 1/8” (28,6 mm) hex Series 3 - 1 1/4” (31,8 mm) hex Series 4 - 1 5/8” (41,0 mm) hex Adjust Screw Locknut Adapter Locknut Key Use this kit to adapt all L controls to K controls (except Series 0 and counterbalance cartridges). 991-222 K control for Series 0 Panel Handknob Kit 991-215 O controls All Series 1 cartridges 7/8” (22,2 mm) hex M20 thread Panel Handknob Kit 991-216 O controls All Series 2 cartridges 1 1/8” (28,6 mm) hex 1”-14 thread H Calibrated Handknob Kit H controls All series of flow controls 991-219 FDCB , NCEB, NCEC , NFDC, NFDD only 991-220 FDEA, FDFA, NCFB, NCFC, NCGB, NCGC, NFEC, NFED, NFFC, NFFD only 991-221 FDBA , NCCB , NCCC , NFCC, NFDC only Lockwire 911-012 All M, Q and R controls (except solenoid operated cartridges). Adjustment For cartridge models: Screw Kit CKCA L**CKCD L** 991-112-003 Viton CKCB L**CPCA L** 991-112-007 Buna-N CKCC L** Adjustment For cartridge models: Screw Kit CKEA L**CKED L** 991-212-003 Viton CKEB L**CPEA L** 991-212-007 Buna-N CKEC L** US Selected Assemblies Catalogue #999-901-192 1. Adjust valve to desired setting and tighten locknut. 2. Using an arbor press or a soft hammer, install cover until it seats on cartridge hex. 3. Cover is a press fit on cartridge shoulder. Cover For all Sun cartridges with L adjustment (except Series 0 and counterbalance cartridges). K Handknob Kit 991-211 To assure a complete seal on the stem - release all pressure on the cartridge after setting. Then... tighten locknut (and cap, on J). Tamper Resistant Cover For all Sun cartridges with L-adjustment Lock Assembly Key Lock Kit 993-008 Notes Wire Stop Ring Handknob Assembly Handknob Assembly Lock Knob 1. Remove original wire stop ring and locknut. 2. Thread on the adapter locknut and install new wire stop ring through slot provided. 3. Adjust valve to desired setting and tighten adapter locknut. 4. Slide lock assembly over adapter, lock and remove key. Only cartridges date stamped “41” or later and originally supplied with plastic knobs. Lock knob snaps onto locknut furnished on cartridge. Lock Knob Only for cartridges originally supplied with an H handknob. Valves can not be modified in the field. Handknob Locking Wire Manual Release Screw Lockring O-ring Exsisting Cartridge Note: The H control is Only available for the cartridges shown to the left. Lead Seal Back-up Ring Only cartridges date stamped “62” or earlier. Locknut 245 Seal General Information CAVITY PLUGS It is sometimes desirable to remove a Sun cartridge valve and still maintain the integrity of the hydraulic system. This may be necessitated by the need to flush a system after repairs or a piping change, or to change an operating function in the circuit. For these requirements, Sun offers two styles of cavity plugs - all ports blocked and main ports open to flow. Plugs for Two Port Cavities: All Ports Open P 0 T-162A XZOA-XX* XZCA-XX* T-10A XFCA-XX* Series 1 2 2 1 All Ports Blocked Cavity Plug Cavity Model Code T-8A XAOA-XX* T-13A T-3A T-5A Cavity Plug Model Code XACA-XX* XFOA-XX* XGCA-XX* 2 XCCA-XX* XCOA-XX* XDCA-XX* 3 T-16A XIOA-XX* XICA-XX* 4 T-18A XKOA-XX* XKCA-XX* 1 Plugs for Three Port Cavities Ports 1 to 2 Open Port 3 Blocked 3 2 1 Series Cavity P T-9A Cavity Plug Model Code All Ports Blocked Cavity Plug Model Code XAOB-XX* XACB-XX* 0 T-163A XZOB-XX* XZCB-XX* 1 T-11A XEOA-XX* XECA-XX* 2 T-2A XBOA-XX* XBCA-XX* 3 T-17A XHOA-XX* XHCA-XX* 4 T-19A XJOA-XX* XJCA-XX* 3 2 1 Plugs for Four Port Cavities (Internal Locating Shoulder) Ports 1 to 2 Open Port 3 and 4 Blocked 4 Series 3 2 1 Cavity Cavity Plug Model Code All Ports Blocked Cavity Plug Model Code 1 T-21A XMOA-XX* XMCA-XX* 2 T-22A XNOA-XX* XNCA-XX* 3 T-23A XPOA-XX* XPCA-XX* 4 T-24A XQOA-XX* XQCA-XX* 4 3 2 1 *Insert in the seventh position model code digit N to order Buna-N seals or V to order Viton seals. 246 US Selected Assemblies Catalogue #999-901-192 General Information CAVITY PLUGS Plugs for Four Port Cavities (External Locating Shoulder) All Ports Open 4 Series 3 2 Cavity Cavity Plug Model Code* All Ports Blocked Cavity Plug Model Code* 1 T-31A XFOA-XX* XRCA-XX* 2 T-32A XCOA-XX* XSCA-XX* 3 T-33A XIOA-XX* XTCA-XX* 4 T-34A XKOA-XX* XVCA-XX* 4 3 2 1 1 Plugs for Six Port Cavities 6 Ports 1, 2, 3 and 4 Open Ports 5 and 6 Blocked 5 Series 4 3 2 Cavity Cavity Plug Model Code* All Ports Blocked Cavity Plug Model Code* 1 T-61A XMOA-XX* XRCC-XX* 2 T-62A XNOA-XX* XSCC-XX* 3 T-63A XPOA-XX* XTCC-XX* 4 T-64A XQOA-XX* XVCC-XX* 6 5 4 3 2 1 1 Cavity Adaptor (Adapts Waterman 12-2 Cavity to the Sun T-8A Cavity) All Ports Open Cavity 2 12-2 Cavity Plug Model Code* XAAA-8X* 1 *Insert in the seventh position model code digit N to order Buna-N seals or V to order Viton seals. US Selected Assemblies Catalogue #999-901-192 247 General Information SOLENOID ELECTRICAL CONNECTOR OPTIONS Pilot Flow Solenoid Valves: DAAA, DBAA ISO / DIN 43650 SAE J858-A Twin Lead Description Coil only part number Coil only part number Coil only part number 115 V AC 50/60 Hz 760-211 N/A N/A 230 V AC 50/60 Hz 760-223 N/A N/A 6 V DC 760-206 760-506 N/A 12 V DC 760-212 760-512 760-712 24 V DC 760-224 760-524 760-724 36 V DC 760-236 N/A N/A 48 V DC 760-248 N/A N/A Full Flow Solenoid Valves: DLDA, DTDA, DMDA, DNDA ISO / DIN 43650 Twin Lead AMP® Junior Timer Description Coil only part number Coil only part number Coil only part number 115 V AC 50/60 Hz 770-211 N/A N/A 230 V AC 50/60 Hz 770-223 N/A N/A 12 V DC 770-212 770-612 770-712 24 V DC 770-224 770-624 770-724 48 V DC 770-248 770-648 770-748 AMP® is a registered trademark. 248 US Selected Assemblies Catalogue #999-901-192 General Information ORIFICE PRESSURE DROP DATA No allowance has been made for viscosity effects, or regain of pressure downstream. Orifice diameter, inches 1 64 4000 1 32 1 16 3 32 3000 2500 Pressure Drop – psi 2000 1500 1 8 1000 500 5 32 3 16 200 These charts are based on the formula: 7 32 100 Q ∅ C ± A ± 2 gH Where: Q = Flow in Cu. Ft. per Sec. C = Orifice Coefficient A = Area of Orifice in Sq. Ft. H = Pressure Head in Ft. 50 25 10 1 4 3 8 0 1 2 3 4 5 6 7 8 9 10 1 2 Flow – GPM Specify Gravity of Fluid = .895 This equation becomes Q(GPM) = 24.12 ± A(sq.in.) ± Pressure Drop (psi) when C ∅ 0.6 4000 3 32 Orifice diameter, inches 5 32 1 8 3 16 7 32 1 4 5 16 3000 2500 Pressure Drop – psi 2000 1500 3 8 1000 7 16 500 1 2 9 16 200 100 5 8 50 25 10 7 8 3 4 1 0 10 20 30 40 50 Flow – GPM US Selected Assemblies Catalogue #999-901-192 5 16 249 60 70 80 90 100 7 16 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES P T-8A 2 Port Sun Cavity Minimum Clearance Distances: .453 Manifold Edge .861 Minimum Hex Extension 1.250 Socket Wrench Clearance (not included on Form Drill) .703 .705 .219 Maximum L.S. Depth without Socket Clearance .136 o 60 1.000 0.000 Socket Diameter Hex Point CLto CL * 0.000 Locating Shoulder .656 .657 .141 M16 x 1.5-6H .570 .574 .391 Minimum Full Thread Bottom Tap Required .531 .437 .439 .750 .754 Deep Socket* (.031 minimum below surface) .188 Maximum .438 Port 2 Centerline Cartridge Nose Support Port 1 .250 Maximum * See respective Pilot Stage Cartridge Outline Drawing for Deep Socket and Hex Point clearance centerline dimensions High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-008-001 994-008-101 TD-8A Form Reamer 995-008-001 995-008-101 TR-8A Metric Tap 998-991 998-991-101 M16x1.5-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 7/8” Hex Deep Socket: Cavity Diameters to be concentric to threads within .002. Sun P/N: 998-100-006, Snap-On P/N: SIML280 © SUN Hydraulics Corporation T-9A 3 Port Sun Cavity .861 Minimum Hex Extension 1.250 Minimum Clearance Distances: (not included on Form Drill) .703 .705 Deep Socket* .219 Maximum L.S. Depth without Socket Clearance o 60 1.000 .136 0.000 Locating Shoulder 0.000 .656 .657 .141 M16 x 1.5-6H .570 .574 .391 Minimum Full Thread Bottom Tap Required .531 Socket Diameter (.031 minimum below surface) .188 .125 Maximum .812 Port 2 Centerline .875 .437 .439 Port 1 .250 Maximum Hex Point CLto CL * Maximum .438 Port 3 Centerline .500 .502 1.095 1.100 .453 Manifold Edge Socket Wrench Clearance Cartridge Nose Support * See respective Pilot Stage Cartridge Outline Drawing for Deep Socket and Hex Point clearance centerline dimensions. High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-009-001 994-009-101 TD-9A Form Reamer 995-009-001 995-009-101 TR-9A Metric Tap 998-991 998-991-101 M16x1.5-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 7/8” Hex Deep Socket: Sun P/N: 998-100-006, Snap-On P/N: SIML280 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation US Selected Assemblies Catalogue #999-901-192 250 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 0 T-162A 2 Port Sun Cavity 1.125 Minimum Clearance Distances: Socket Wrench Clearance (included on Form Drill) .453 Manifold Edge .812 Minimum Hex Extension .969 Deep Socket .484 .936 .940 .273 o 45 (2) Places Socket Diameter .703 .705 0.000 .156 (.031 minimum below surface) .656 .657 .531 Maximum M16x1.5-6H .531 Minimum Full Thread 25 .641 Port 2 Centerline o .570 .574 .908 1.219 1.222 .875 Hex Point CLto CL 0.000 Locating Shoulder .515 .517 1.297 Minimum Depth of .406 for Working Parts Clearance Cartridge Nose Support Port 1 High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-162-001 994-162-101 TD-162A Form Reamer 995-162-001 995-162-101 TR-162A Metric Tap 998-991 998-991-101 M16x1.5-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 3/4” Hex Deep Socket: .406 Maximum Sun P/N: 998-100-005, Snap-On P/N: S241 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation T-163A 3 Port Sun Cavity 1.125 Minimum Clearance Distances: Socket Wrench Clearance (included on Form Drill) .936 .940 .484 Manifold Edge .969 Deep Socket 1.188 Minimum Hex Extension o 30 o 45 (2) Places .906 .696 .609 Minimum Surface from L.S. .312 Maximum .703 .705 Socket Diameter .875 Hex Point CLto CL .188 Port 3 Centerline 0.000 .156 0.000 Locating Shoulder .656 .657 .531 M16x1.5-6H Maximum .531 Minimum Full Thread .641 Port 2 Centerline o .908 1.219 1.222 .570 .574 25 .515 .517 1.297 Minimum Depth of .406 for Working Parts Clearance Port 1 Cartridge Nose Support .406 Maximum High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-163-001 994-163-101 TD-163A Form Reamer 995-163-001 995-163-101 TR-163A Metric Tap 998-991 998-991-101 M16x1.5-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 3/4” Hex Deep Socket: Sun P/N: 998-100-005, Snap-On P/N: S241 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation 251 US Selected Assemblies Catalogue #999-901-192 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 1 T-10A 2 Port Sun Cavity 1.250 Minimum Clearance Distances: Socket Wrench Clearance (not included on Form Drill) .688 Minimum Hex Extension 1.000 o 45 (3) Places .156 .859 .861 Socket Diameter 0.000 Locating Shoulder .812 .814 1.062 Hex Point CLto CL (.031 minimum below surface) .875 M20x1.5-6H Maximum .500 Minimum Full Thread .812 Port 2 Centerline .730 .734 1.266 1.567 1.572 .687 .689 1.810 Minimum Depth of .531 for Working Parts Clearance 1.125 Deep Socket .438 Maximum L.S. Depth without Socket Clearance .227 0.000 .562 Manifold Edge Cartridge Nose Support Port 1 High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-010-001 994-010-101 TD-10A Form Reamer 995-010-001 995-010-101 TR-10A Metric Tap 998-998 998-998-101 M20x1.5-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 7/8” Hex Deep Socket: Sun P/N: 998-100-001, Snap-On P/N: S281 .531 Maximum Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation T-13A 2 Port Sun Cavity 1.250 Minimum Clearance Distances: Socket Wrench Clearance (not included on Form Drill) .562 Manifold Edge .688 Minimum Hex Extension .998 1.002 1.125 Deep Socket o 45 (3) Places .438 Maximum L.S. Depth without Socket Clearance .227 0.000 .859 .861 .812 .814 .156 1.062 Hex Point CLto CL (.031 minimum below surface) .688 Maximum M20x1.5-6H .500 Minimum Full Thread .719 Port 2 Centerline .730 .734 1.078 1.380 1.385 Socket Diameter 0.000 Locating Shoulder .687 .689 1.59 Minimum Depth of .531 for Working Parts Clearance Cartridge Nose Support Port 1 7/8” Hex Deep Socket: .531 Maximum Sun P/N: 998-100-001, Snap-On P/N: S281 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation US Selected Assemblies Catalogue #999-901-192 High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-013-001 994-013-101 TD-13A Form Reamer 995-013-001 995-013-101 TR-13A Metric Tap 998-998 998-998-101 M20x1.5-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 252 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 1 T-11A 3 Port Sun Cavity 1.250 Minimum Clearance Distances: Socket Wrench Clearance (not included on Form Drill) .594 Manifold Edge 1.188 Minimum Hex Extension 1.000 .938 Maximum L.S. Depth without Socket Clearance o 45 (3) Places .688 Minimum Surface from L.S. .422 Maximum .721 .859 .861 0.000 .156 1.125 Deep Socket 1.062 Hex Point CLto CL .219 Port 3 Centerline 0.000 Locating Shoulder .812 .814 .688 M20x1.5-6H Maximum .500 Minimum Full Thread .719 Port 2 Centerline .730 .734 1.078 .687 .689 1.380 1.385 Socket Diameter 1.59 Minimum Depth of .531 for Working Parts Clearance Cartridge Nose Support Port 1 High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-011-001 994-011-101 TD-11A Form Reamer 995-011-001 995-011-101 TR-11A Metric Tap 998-998 998-998-101 M20x1.5-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 7/8” Hex Deep Socket: Sun P/N: 998-100-001, Snap-On P/N: S281 .531 Maximum Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation T-21A 4 Port Sun Cavity 1.250 Minimum Clearance Distances: Socket Wrench Clearance (not included on Form Drill) .625 Manifold Edge 1.781 Minimum Hex Extension 1.000 o 1.438 Maximum L.S. Depth without Socket Clearance 1.188 Minimum Surface from L.S. .250 Maximum 45 (4) Places 1.211 .889 .891 Socket Diameter .812 Port 4 Centerline .671 1.062 Hex Point CLtoCL .312 .859 .861 0.000 Locating Shoulder .812 .814 .688 M20x1.5-6H .500 Minimum Full Thread 1.380 1.385 Maximum .719 Port 2 Centerline .730 .734 1.078 Maximum .188 Port 3 Centerline 0.000 .156 1.125 Deep Socket .687 .689 1.59 Minimum Depth of .531 for Working Parts Clearance Port 1 Cartridge Nose Support .531 Maximum High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-021-001 994-021-101 TD-21A Form Reamer 995-021-001 995-021-101 TR-21A Metric Tap 998-998 998-998-101 M20x1.5-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 7/8” Hex Deep Socket: Sun P/N: 998-100-001, Snap-On P/N: S281 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation 253 US Selected Assemblies Catalogue #999-901-192 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 1 T-31A 4 Port Sun Cavity 1.250 Socket Wrench Clearance (not included on Form Drill) .859 .861 0.000 .562 Manifold Edge (not included on Form Drill) .219 Maximum L.S. Depth without Hex Clearance 0.000 Locating Shoulder .812 .814 .156 Minimum Clearance Distances: .156 Minimum Hex Extension .438 Maximum L.S. Depth without Socket Clearance 1.000 Hex Clearance 1.125 Deep Socket (.031 minimum below surface) M20x1.5-6H .500 Minimum Full Thread .625 .730 .734 Maximum Socket Diameter 1.062 Hex Point CLto CL .844 Port 4 Centerline 1.170 .562 .697 .699 Maximum High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-031-001 994-031-101 TD-31A Form Reamer 995-031-001 995-031-101 TR-31A Metric Tap 998-998 998-998-101 M20x1.5-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1.781 Port 3 Centerline 2.075 .562 .661 .663 Maximum 2.688 Port 2 Centerline 2.990 .625 .627 3.351 3.355 4.03 Minimum Depth of .469 for Working Parts Clearance Cartridge Nose Support 7/8” Hex Deep Socket: Port 1 .469 Max. Sun P/N: 998-100-001, Snap-On P/N: S281 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation T-61A 6 Port Sun Cavity 1.250 Minimum Clearance Distances: Socket Wrench Clearance 1.781 Minimum Hex Extension (not included on Form Drill) 1.000 1.438 Maximum L.S. Depth without Socket Clearance 1.188 Minimum Surface from L.S. 1.211 .671 .250 .889 .891 .625 Manifold Edge Maximum .812 Port 6 Centerline .312 .859 .861 Maximum .188 Port 5 Centerline 0.000 Locating Shoulder 0.000 .812 .814 .156 M20x1.5-6H .500 Minimum Full Thread .730 .734 .625 Socket Diameter 1.062 Hex Point CLto CL Maximum .844 Port 4 Centerline High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-061-001 994-061-101 TD-61A Form Reamer 995-061-001 995-061-101 TR-61A Metric Tap 998-998 998-998-101 M20x1.5-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1.170 .562 .697 .699 Maximum 1.781 Port 3 Centerline 2.075 .562 .661 .663 2.990 3.351 3.355 1.125 Deep Socket Maximum 2.688 Port 2 Centerline .625 .627 3.500 Minimum Depth of .469 for Working Parts Clearance Port 1 .469 Max. Cartridge Nose Support 7/8” Hex Deep Socket: Sun P/N: 998-100-001, Snap-On P/N: S281 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation US Selected Assemblies Catalogue #999-901-192 254 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 2 T-3A 2 Port Sun Cavity 1.500 Minimum Clearance Distances: Socket Wrench Clearance (not included on Form Drill) .719 Manifold Edge .719 Minimum Hex Extension 1.312 1.438 Deep Socket .438 Maximum L.S. Depth without Socket Clearance 1.078 1.080 60 o .172 Socket Diameter 0.000 Locating Shoulder 0.000 (.031 minimum below surface) 1.031 1.033 .156 1.125 1”-14UNS-2B .625 Minimum Full Thread .933 .937 .969 Port 2 Centerline o 45 Typical (2) Places 1.547 .875 .877 Cartridge Nose Support + .0025 1.885 _ 2.25 Minimum Depth of .688 for Working Parts Clearance Port 1 1.375 Hex Point CLto CL Maximum High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-003-001 994-003-101 TD-3A Form Reamer 995-003-001 995-003-101 TR-3A UNS Tap 998-999 998-999-101 1”-14 Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 1/8” Hex Deep Socket: Sun P/N: 998-100-002, Snap-On P/N: S361 .688 Maximum Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation T-5A 2 Port Sun Cavity Minimum Clearance Distances: 1.500 Socket Wrench Clearance .719 Manifold Edge (not included on Form Drill) .688 Minimum Hex Extension 1.312 1.438 Deep Socket .438 Maximum L.S. Depth without Socket Clearance 1.078 1.080 Socket Diameter 1.172 0.000 .156 (.031 minimum below surface) .875 Maximum 1”-14UNS-2B .625 Minimum Full Thread .844 Port 2 Centerline .933 .937 1.297 1.635 (±.0025) .875 .877 2.00 Minimum Depth of .688 for Working Parts Clearance 1.375 Hex Point CLto CL 0.000 Locating Shoulder 1.031 1.033 Port 1 Cartridge Nose Support High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-005-001 994-005-101 TD-5A Form Reamer 995-005-001 995-005-101 TR-5A UNS Tap 998-999 998-999-101 1”-14 Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 1/8” Hex Deep Socket: .688 Maximum Sun P/N: 998-100-002, Snap-On P/N: S361 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation 255 US Selected Assemblies Catalogue #999-901-192 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 2 T-2A 3 Port Sun Cavity 1.500 Minimum Clearance Distances: Socket Wrench Clearance (not included on Form Drill) .750 Manifold Edge o 45 Typical (3) Places 1.375 Minimum Hex Extension 1.438 Deep Socket 1.125 Maximum L.S. Depth without Socket Clearance 1.312 .804 .719 Minimum Surface from L.S. .375 1.078 1.080 0.000 Locating Shoulder 1.031 1.033 .625 1”-14UNS-2B .625 Minimum Full Thread Maximum .719 Port 2 Centerline .933 .937 1.047 1.375 Hex Point CLto CL .219 Port 3 Centerline 0.000 .156 Socket Diameter Maximum .875 .877 + .0025 1.385 _ 1.781 Minimum Depth of .688 for Working Parts Clearance Cartridge Nose Support Port 1 High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-002-001 994-002-101 TD-2A Form Reamer 995-002-001 995-002-101 TR-2A UNS Tap 998-999 998-999-101 1”-14 Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 1/8” Hex Deep Socket: .688 Maximum Sun P/N: 998-100-002, Snap-On P/N: S361 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation T-22A 4 Port Sun Cavity Minimum Clearance Distances: 1.500 Socket Wrench Clearance (not included on Form Drill) .766 Manifold Edge 2.000 Minimum Hex Extension o 45 Typical (4) Places 1.719 Maximum L.S. Depth without Socket Clearance 1.312 1.312 Minimum Surface from L.S. .312 Maximum 1.383 1.108 1.110 Socket Diameter .875 Port 4 Centerline .688 0.000 1.438 Deep Socket 1.375 Hex Point CLto CL .312 1.078 1.080 .219 Port 3 Centerline 1.031 1.033 0.000 Locating Shoulder .156 .625 1”-14UNS-2B .625 Minimum Full Thread + .0025 1.385 _ .875 .877 1.781 Minimum Depth of .688 for Working Parts Clearance Maximum .719 Port 2 Centerline .933 .937 1.047 Maximum Port 1 Cartridge Nose Support High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-022-001 994-022-101 TD-22A Form Reamer 995-022-001 995-022-101 TR-22A UNS Tap 998-999 998-999-101 1”-14 Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 1/8” Hex Deep Socket: .688 Maximum Sun P/N: 998-100-002, Snap-On P/N: S361 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation US Selected Assemblies Catalogue #999-901-192 256 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 2 T-32A 4 Port Sun Cavity 1.500 Socket Wrench Clearance (not included on Form Drill) 1.078 1.080 0.000 .688 Minimum Hex Extension .438 Maximum L.S. Depth without Socket Clearance 1.312 Hex Clearance Minimum Clearance Distances: .720 Manifold Edge (not included on Form Drill) .172 Maximum L.S. Depth without Hex Clearance 0.000 Locating Shoulder 1.031 1.033 1.438 Deep Socket (.031 minimum below surface) .156 .750 1”-14UNS-2B .625 Minimum Full Thread Maximum Socket Diameter .953 Port 4 Centerline .933 .937 1.375 Hex Point CLto CL 1.344 .562 .895 .897 Maximum 1.984 Port 3 Centerline 2.281 .562 .854 .856 Maximum 2.938 Port 2 Centerline 3.234 .812 .814 3.633 3.637 4.375 Minimum Depth of .625 for Working Parts Clearance Port 1 .625 Maximum Cartridge Nose Support High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-032-001 994-032-101 TD-32A Form Reamer 995-032-001 995-032-101 TR-32A UNS Tap 998-999 998-999-101 1”-14UNS-2B Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 1/8” Hex Deep Socket: Sun P/N: 998-100-002, Snap-On P/N: S361 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation T-62A 6 Port Sun Cavity Minimum Clearance Distances: 1.500 Socket Wrench Clearance (not included on Form Drill) 1.312 .688 .312 1.078 1.080 Maximum 1.031 1.033 .750 .895 .897 Maximum 1.984 Port 3 Centerline 2.281 .562 .854 .856 Maximum 2.938 Port 2 Centerline .812 .814 3.75 Minimum Depth of .625 for Working Parts Clearance Port 1 .625 Max. 1.375 Hex Point CLto CL Maximum .953 Port 4 Centerline .562 3.633 3.637 Socket Diameter .219 Port 5 Centerline 0.000 Locating Shoulder 1”-14UNS-2B .625 Minimum Full Thread .933 .937 1.344 3.234 1.438 Deep Socket .312 Maximum .875 Port 6 Centerline 1.108 1.110 .156 .766 Manifold Edge 1.312 Minimum Surface from L.S. 1.281 0.000 2.000 Minimum Hex Extension 1.719 Maximum L.S. Depth without Socket Clearance Cartridge Nose Support High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-062-001 994-062-101 TD-62A Form Reamer 995-062-001 995-062-101 TR-62A UNS Tap 998-999 998-999-101 1”-14UNS-2B Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 1/8” Hex Deep Socket: Sun P/N: 998-100-002, Snap-On P/N: S361 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation 257 US Selected Assemblies Catalogue #999-901-192 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 3 T-16A 2 Port Sun Cavity .969 Minimum Hex Extension 1.750 Minimum Clearance Distances: Socket Wrench Clearance (included on Form Drill) 1.031 Manifold Edge .234 ref 1.781 Deep Socket 1.562 1.564 0.000 0.000 Locating Shoulder 1.438 1.440 .188 Socket Diameter (.031 minimum below surface) 1.500 M36x2-6H Maximum 1.781 Hex Point CLto CL .688 Minimum Full Thread 1.343 1.347 1.312 Port 2 Centerline o 45 Typical (2) Places 2.062 1.250 1.252 + .0025 2.448 _ 2.84 Minimum Depth of 1.000 for Working Parts Clearance Cartridge Nose Support Port 1 High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-016-001 994-016-101 TD-16A Form Reamer 995-016-001 995-016-101 TR-16A Metric Tap 998-996 998-996-101 M36x2-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 1/4” Hex Deep Socket: 1.000 Maximum Sun P/N: 998-100-003, Snap-On P/N: S401 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation T-17A 3 Port Sun Cavity 1.812 Minimum Hex Extension 1.750 Minimum Clearance Distances: Socket Wrench Clearance (included on Form Drill) 1.109 Manifold Edge o 45 Typical (3) Places 1.875 Deep Socket .969 ref .906 Minimum Surface from L.S. .562 Maximum .875 1.562 1.564 0.000 1.438 1.440 .875 M36x2-6H Maximum .688 Minimum Full Thread 1.000 Port 2 Centerline 1.343 1.347 1.438 1.250 1.252 2.234 Minimum Depth of 1.000 for Working Parts Clearance 1.875 Hex Point CLto CL 0.000 Locating Shoulder .188 + .0025 1.822 _ Socket Diameter .312 Port 3 Centerline Port 1 Cartridge Nose Support 1 1/4” Hex Deep Socket: Sun P/N: 998-100-003, Snap-On P/N: S401 1.000 Maximum Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation US Selected Assemblies Catalogue #999-901-192 High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-017-001 994-017-101 TD-17A Form Reamer 995-017-001 995-017-101 TR-17A Metric Tap 998-996 998-996-101 M36x2-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 258 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 3 T-23A 4 Port Sun Cavity 2.469 Minimum Hex Extension 1.750 Minimum Clearance Distances: Socket Wrench Clearance 1.125 Manifold Edge (included on Form Drill) o 45 Typical (4) Places 1.938 Deep Socket 1.672 ref 1.625 Minimum Surface from L.S. 1.594 .375 Maximum 1.592 1.594 1.125 Port 4 Centerline 1.562 1.564 .281 Port 3 Centerline Socket Diameter .875 .500 0.000 0.000 Locating Shoulder 1.438 1.440 .188 M36x2-6H .688 Minimum Full Thread .875 1.343 1.347 1.438 + .0025 1.822 _ Maximum 1.000 Port 2 Centerline 1.250 1.252 Cartridge Nose Support Port 1 2.234 Minimum Depth of 1.000 for Working Parts Clearance 1.938 Hex Point CLto CL Maximum High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-023-001 994-023-101 TD-23A Form Reamer 995-023-001 995-023-101 TR-23A Metric Tap 998-996 998-996-101 M36x2-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 1/4” Hex Deep Socket: 1.000 Maximum Sun P/N: 998-100-003, Snap-On P/N: S401 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation T-33A 4 Port Sun Cavity .688 Minimum Hex Extension 1.750 Minimum Clearance Distances: Socket Wrench Clearance (not included on Form Drill) 0.000 .188 1.031 Manifold Edge .438 Maximum L.S. Depth without Socket Clearance 1.562 1.564 1.781 Deep Socket 0.000 Locating Shoulder 1.438 1.440 (.031 minimum below surface) 1.062 M36 x 2-6H .688 Minimum Full Thread 1.343 1.347 Maximum Socket Diameter 1.188 Port 4 Centerline 1.781 Hex Point CLto CL 1.734 .719 1.296 1.298 Maximum 2.500 Port 3 Centerline 2.875 .719 1.250 1.252 Maximum 3.672 Port 2 Centerline 4.047 4.508 4.512 1.203 1.205 5.50 Minimum Depth of .875 for Working Parts Clearance Port 1 Cartridge Nose Support .875 Maximum High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-033-001 994-033-101 TD-33A Form Reamer 995-033-001 995-033-101 TR-33A Metric Tap 998-996 998-996-101 M36x2-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 1/4” Hex Deep Socket: Sun P/N: 998-100-003, Snap-On P/N: S401 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation 259 US Selected Assemblies Catalogue #999-901-192 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 3 T-63A 1.750 6 Port Sun Cavity Minimum Clearance Distances: 2.469 Minimum Hex Extension 1.672 ref 1.625 Minimum Surface from L.S. .375 Maximum Socket Wrench Clearance (included on Form Drill) 1.594 1.592 1.594 1.125 Manifold Edge 1.125 Port 6 Centerline .875 .500 1.562 1.564 Maximum .281 Port 5 Centerline 0.000 Locating Shoulder 0.000 1.438 1.440 M36 x 2-6H .688 Minimum Full Thread .188 1.062 1.188 Port 4 Centerline 1.734 .719 1.296 1.298 Maximum 2.500 Port 3 Centerline 2.875 .719 1.250 1.252 4.508 4.512 Maximum 3.672 Port 2 Centerline 1.203 1.205 4.750 Minimum Depth of .875 for Working Parts Clearance Socket Diameter Maximum 1.938 Hex Point CLto CL 1.343 1.347 4.047 1.938 Deep Socket Port 1 .875 Max. Cartridge Nose Support 1 1/4” Hex Deep Socket: Sun P/N: 998-100-003, Snap-On P/N: S401 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation US Selected Assemblies Catalogue #999-901-192 High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-063-001 994-063-101 TD-63A Form Reamer 995-063-001 995-063-101 TR-63A Metric Tap 998-996 998-996-101 M36x2-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 260 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 4 T-18A 2 Port Sun Cavity 1.188 Minimum Hex Extension 2.312 Minimum Clearance Distances: Socket Wrench Clearance 1.375 Manifold Edge (included on Form Drill) .297 ref 2.281 Deep Socket 2.062 2.064 0.000 1.912 1.914 0.000 Locating Shoulder Socket Diameter (.031 minimum below surface) .219 M48x2-6H 1.875 2.281 Hex Point CLto CL Maximum .875 Minimum Full Thread 1.813 1.817 1.688 Port 2 Centerline o 45 Typical (2) Places 2.594 1.625 1.627 Cartridge Nose Support + .0025 3.135 _ 3.59 Minimum Depth of 1.250 for Working Parts Clearance Port 1 High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-018-001 994-018-101 TD-18A Form Reamer 995-018-001 995-018-101 TR-18A Metric Tap 998-992 998-992-101 M48x2-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 5/8” Hex Deep Socket: 1.250 Maximum Sun P/N: 998-100-004, Snap-On P/N: LS522 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation T-19A 3 Port Sun Cavity Minimum Clearance Distances: 2.312 Minimum Hex Extension 2.312 Socket Wrench Clearance 1.500 Manifold Edge (not included on Form Drill) o 45 Typical (3) Places 1.250 ref 1.156 Minimum Surface from L.S. 1.125 .750 0.000 .219 Maximum 2.062 2.064 .438 Port 3 Centerline 1.912 1.914 0.000 Locating Shoulder M48x2-6H 1.250 Maximum .875 Minimum Full Thread 1.969 1.375 Port 2 Centerline 1.813 1.817 1.625 1.627 + .0025 2.510 _ 2.98 Minimum Depth of 1.250 for Working Parts Clearance 2.469 Deep Socket Port 1 Cartridge Nose Support Socket Diameter 2.469 Hex Point CLto CL High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-019-001 994-019-101 TD-19A Form Reamer 995-019-001 995-019-101 TR-19A Metric Tap 998-992 998-992-101 M48x2-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 5/8” Hex Deep Socket: 1.250 Maximum Sun P/N: 998-100-004, Snap-On P/N: LS522 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation 261 US Selected Assemblies Catalogue #999-901-192 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 4 T-24A 4 Port Sun Cavity 3.125 Minimum Hex Extension 2.312 Minimum Clearance Distances: Socket Wrench Clearance (included on Form Drill) o 45 Typical (4) Places 2.078 ref 2.000 Minimum Surface from L.S. .500 Maximum 1.969 2.092 2.094 1.125 2.062 2.064 Socket Diameter Maximum 2.531 Hex Point CLto CL .406 Port 3 Centerline 0.000 0.000 Locating Shoulder 1.912 1.914 M48x2-6H 1.25 Maximum .875 Minimum Full Thread 1.813 1.817 1.375 Port 2 Centerline 1.969 + .0025 2.510 _ 2.531 Deep Socket 1.438 Port 4 Centerline .688 .219 1.531 Manifold Edge 1.625 1.627 Cartridge Nose Support Port 1 2.984 Minimum Depth of 1.250 for Working Parts Clearance High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-024-001 994-024-101 TD-24A Form Reamer 995-024-001 995-024-101 TR-24A Metric Tap 998-992 998-992-101 M48x2-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 5/8” Hex Deep Socket: 1.250 Maximum Sun P/N: 998-100-004, Snap-On P/N: LS522 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation T-34A 4 Port Sun Cavity Minimum Clearance Distances: 1.188 Minimum Hex Extension 0.000 2.312 Socket Wrench Clearance (not included on Form Drill) .438 Maximum L.S. Depth without Socket Clearance 0.000 Locating Shoulder 2.062 2.063 1.912 1.914 M48x2-6H .875 Minimum Full Thread 1.375 Manifold Edge (.031 minimum below surface) 1.250 1.813 1.817 Maximum Socket Diameter 1.375 Port 4 Centerline 2.281 Hex Point CLto CL 2.016 1.000 1.766 1.768 Maximum 3.000 Port 3 Centerline 3.516 1.000 1.719 1.721 Maximum 4.500 Port 2 Centerline 5.016 5.508 5.512 1.672 1.674 6.56 Minimum Depth of 1.312 for Working Parts Clearance 2.281 Deep Socket Cartridge Nose Support 1 5/8” Hex Deep Socket: Port 1 1.312 Maximum Sun P/N: 998-100-004, Snap-On P/N: LS522 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation US Selected Assemblies Catalogue #999-901-192 High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-034-001 994-034-101 TD-34A Form Reamer 995-034-001 995-034-101 TR-34A Metric Tap 998-992 998-992-101 M48x2-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 262 General Information: Cartridge Cavities and Cavity Tools NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation. Complete cavity machining dimensions are provided with form tools or supplied upon request. Dimensions shown below are simplified for manifold design purposes. SERIES 4 T-64A 2.312 6 Port Sun Cavity 3.125 Minimum Hex Extension Socket Wrench Clearance (included on Form Drill) 2.078 Maximum L.S. Depth without Socket Clearance 2.000 .500 Maximum 1.969 1.125 Minimum Clearance Distances: 2.092 2.094 1.53 Manifold Edge 1.438 Port 6 Centerline .688 2.062 2.064 2.531 Deep Socket Maximum .406 Port 5 Centerline 0.000 0.000 Locating Shoulder 1.912 1.914 .219 M48x2-6H .875 Minimum Full Thread 1.813 1.817 1.250 Socket Diameter Maximum 2.531 Hex Point CLto CL 1.375 Port 4 Centerline 2.016 1.000 1.766 1.768 3.000 Port 3 Centerline 3.516 1.000 1.719 1.721 5.016 5.508 5.512 Maximum 4.500 Port 2 Centerline 1.672 1.674 5.75 Minimum Depth of 1.312 for Working Parts Clearance Maximum Cartridge Nose Support Port 1 1.312 Max. High Speed Steel Titanium Coated Description Model Code Model Code Form Drill 994-064-001 994-064-101 TD-64A Form Reamer 995-064-001 995-064-101 TR-64A Metric Tap 998-992 998-992-101 M48x2-6H Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank. 1 5/8” Hex Deep Socket: Sun P/N: 999-100-004, Snap-On P/N: LS522 Cavity Diameters to be concentric to threads within .002. © SUN Hydraulics Corporation 263 US Selected Assemblies Catalogue #999-901-192 Model Code Index CARTRIDGES Model Code Cavity Page Model Code Cavity Page Model Code Cavity Page CBCA - ✱✱✱ T-11A 50 CWIA - ✱✱✱ T-24A 70 PBJB - ✱✱✱ T-19A 34 CBCB - ✱✱✱ T-11A 50 CWIG - ✱✱✱ T-24A 70 PPDB - ✱✱✱ T-11A 42 CBCG - ✱✱✱ T-11A 50 CWIK - ✱✱✱ T-24A 70 PPFB - ✱✱✱ T-2A 42 CBCH - ✱✱✱ T-11A 50 CWIL - ✱✱✱ T-24A 70 PPHB - ✱✱✱ T-17A 42 CBCL - ✱✱✱ T-11A 50 CXAD - ✱✱✱ T-162A 102 PPJB - ✱✱✱ T-19A 42 CBCY - ✱✱✱ T-11A 50 CXBA - ✱✱✱ T-162A 102 PRDB - ✱✱✱ T-11A 42 CBEA - ✱✱✱ T-2A 50 CXCD - ✱✱✱ T-13A 102 PRFB - ✱✱✱ T-2A 42 CBEB - ✱✱✱ T-2A 50 CXDA - ✱✱✱ T-13A 102 PRHB - ✱✱✱ T-17A 42 CBEG - ✱✱✱ T-2A 50 CXED - ✱✱✱ T-5A 102 PRJB - ✱✱✱ T-19A 42 CBEH - ✱✱✱ T-2A 50 CXFA - ✱✱✱ T-5A 102 RDBA - ✱✱✱ T-162A 2 CBEL - ✱✱✱ T-2A 50 CXGD - ✱✱✱ T-16A 102 RDDA - ✱✱✱ T-10A 2 CBEY - ✱✱✱ T-2A 50 CXHA - ✱✱✱ T-16A 102 RDFA - ✱✱✱ T-3A 2 CBGA - ✱✱✱ T-17A 50 CXID - ✱✱✱ T-18A 102 RDHA - ✱✱✱ T-16A 2 CBGB - ✱✱✱ T-17A 50 CXJA - ✱✱✱ T-18A 102 RDJA - ✱✱✱ T-18A 2 CBGG - ✱✱✱ T-17A 50 FCBB - ✱✱✱ T-162A 118 RPCC - ✱✱✱ T-162A 2 CBGH - ✱✱✱ T-17A 50 FCCB - ✱✱✱ T-13A 118 RPEC - ✱✱✱ T-10A 2 CBGL - ✱✱✱ T-17A 50 FCDB - ✱✱✱ T-5A 118 RPGC - ✱✱✱ T-3A 2 CBGY - ✱✱✱ T-17A 50 FCEB - ✱✱✱ T-16A 118 RPIC - ✱✱✱ T-16A 2 CBIA - ✱✱✱ T-19A 50 FCFB - ✱✱✱ T-18A 118 RPKC - ✱✱✱ T-18A 2 CBIB - ✱✱✱ T-19A 50 FDBA - ✱✱✱ T-13A 126 RSBC - ✱✱✱ T-163A 20 CBIG - ✱✱✱ T-19A 50 FDCB - ✱✱✱ T-5A 126 RSDC - ✱✱✱ T-11A 20 CBIH - ✱✱✱ T-19A 50 FDEA - ✱✱✱ T-16A 126 RSFC - ✱✱✱ T-2A 20 CBIL - ✱✱✱ T-19A 50 FDFA - ✱✱✱ T-18A 126 RSHC - ✱✱✱ T-17A 20 CBIY - ✱✱✱ T-19A 50 FRBA - ✱✱✱ T-163A 134 RSJC - ✱✱✱ T-19A 20 CKBB - ✱✱✱ T-163A 78 FRCA - ✱✱✱ T-11A 134 RVBA - ✱✱✱ T-163A 12 CKBD - ✱✱✱ T-163A 78 FRDA - ✱✱✱ T-2A 134 RVCA - ✱✱✱ T-11A 12 CKCB - ✱✱✱ T-11A 78 FREA - ✱✱✱ T-17A 134 RVEA - ✱✱✱ T-2A 12 CKCD - ✱✱✱ T-11A 78 FRFA - ✱✱✱ T-19A 134 RVGA - ✱✱✱ T-17A 12 CKEB - ✱✱✱ T-2A 78 FXBA - ✱✱✱ T-162A 118 RVIA - ✱✱✱ T-19A 12 CKED - ✱✱✱ T-2A 78 FXCA - ✱✱✱ T-13A 118 SCCA - ✱✱✱ T-11A 28 CKGB - ✱✱✱ T-17A 78 FXDA - ✱✱✱ T-5A 118 SCEA - ✱✱✱ T-2A 28 CKGD - ✱✱✱ T-17A 78 FXEA - ✱✱✱ T-16A 118 SCGA - ✱✱✱ T-17A 28 CKIB - ✱✱✱ T-19A 78 FXFA - ✱✱✱ T-18A 118 SCIA - ✱✱✱ T-19A 28 CKID - ✱✱✱ T-19A 78 NCBB - ✱✱✱ T-162A 110 SXCA - ✱✱✱ T-11A 20 CVCV - ✱✱✱ T-21A 94 NCCB - ✱✱✱ T-13A 110 SXEA - ✱✱✱ T-2A 20 CVEV - ✱✱✱ T-22A 94 NCCC - ✱✱✱ T-13A 110 CVGV - ✱✱✱ T-23A 94 NCEB - ✱✱✱ T-5A 110 CVIV - ✱✱✱ T-24A 94 NCEC - ✱✱✱ T-5A 110 CWCA- ✱✱✱ T-21A 70 NCFB - ✱✱✱ T-16A 110 CWCG- ✱✱✱ T-21A 70 NCGB - ✱✱✱ T-18A 110 CWCK- ✱✱✱ T-21A 70 NCGC - ✱✱✱ T-18A 110 CWCL - ✱✱✱ T-21A 70 NFBC - ✱✱✱ T-162A 110 CWEA - ✱✱✱ T-22A 70 NFCC - ✱✱✱ T-13A 110 CWEG- ✱✱✱ T-22A 70 NFDC - ✱✱✱ T-5A 110 CWEK - ✱✱✱ T-22A 70 NFEC - ✱✱✱ T-16A 110 CWEL - ✱✱✱ T-22A 70 NFFC - ✱✱✱ T-18A 110 CWGA- ✱✱✱ T-23A 70 PBBB - ✱✱✱ T-163A 34 CWGG- ✱✱✱ T-23A 70 PBDB - ✱✱✱ T-11A 34 CWGK- ✱✱✱ T-23A 70 PBFB - ✱✱✱ T-2A 34 CWGL - ✱✱✱ T-23A 70 PBHB - ✱✱✱ T-17A 34 US Selected Assemblies Catalogue #999-901-192 264 Model Code Index ASSEMBLIES Model Code Cavity Page Model Code Cavity Page Cavity Page CBE*-L*N-EMB T-11A 205 CBC*-LHN-XVH T-11A 60 CBCA-LAN-WZE T-11A 238 CBE*-L*N-EMC T-11A 205 CBC*-LHN-XVI T-11A 60 CBCA-LAN-WZH T-11A 238 CBE*-L*N-EMJ T-11A 205 CBC*-LHN-YEB T-11A 58 CBCA-LAN-WZL T-11A 239 CBE*-L*N-EMK T-11A 205 CBC*-LHN-YEC T-11A 58 CBCA-LAN-WZP T-11A 239 CBE*-L*N-ENB T-11A 207 CBC*-LHN-YEI T-11A 58 CBCA-LAN-WZS T-11A 239 CBE*-L*N-ENC T-11A 207 CBC*-LHN-YEJ T-11A 58 CBCA-LAN-WZV T-11A 239 CBE*-L*N-ENJ T-11A 207 CBC*-LHN-YEK T-11A 58 CBCA-LAN-XTS T-11A 231 CBE*-L*N-ENK T-11A 207 CBC*-LHN-YGB T-11A 61 CBCA-LAN-YTA T-11A 231 CBE*-L*N-EPB T-11A 209 CBC*-LHN-YGC T-11A 61 CBCA-LAN-ZDV T-11A 231 CBE*-L*N-EPC T-11A 209 CBC*-LHN-YGI T-11A 61 CBCA-LAN-ZDY T-11A 231 CBE*-L*N-EPJ T-11A 209 CBC*-LHN-YGJ T-11A 61 CBCA-LAN-ZPD T-11A 230 CBE*-L*N-EPK T-11A 209 CBC*-LHN-YGK T-11A 61 CBCA-LAN-ZPD T-11A 230 CBE*-L*N-EQB T-11A 211 CBC*-LHN-YVM T-11A 67 CBE*-L*N-BMC T-2A 205 CBE*-L*N-EQC T-11A 211 CBC*-LHN-YVY T-11A 67 CBE*-L*N-BMD T-2A 205 CBE*-L*N-EQJ T-11A 211 CBC*-LHN-ZTC T-11A 66 CBE*-L*N-BMK T-2A 205 CBE*-L*N-EQK T-11A 211 CBC*-LHN-ZTN T-11A 66 CBE*-L*N-BML T-2A 205 CBG*-L*N-HME T-17A 206 CBC*-LJN-EBA T-11A / T-21A 151 CBE*-L*N-BNC T-2A 207 CBG*-L*N-HMF T-17A 206 CBC*-LJN-EBY T-11A / T-21A 151 CBE*-L*N-BND T-2A 207 CBG*-L*N-HMM T-17A 206 CBC*-LJN-ECB T-11A 52 CBE*-L*N-BNK T-2A 207 CBG*-L*N-HMN T-17A 206 CBC*-LJN-ECC T-11A 52 CBE*-L*N-BNL T-2A 207 CBG*-L*N-HNE T-17A 208 CBC*-LJN-ECH T-11A 52 CBE*-L*N-BPC T-2A 209 CBG*-L*N-HNF T-17A 208 CBC*-LJN-ECI T-11A 52 CBE*-L*N-BPD T-2A 209 CBG*-L*N-HNM T-17A 208 CBC*-LJN-ECJ T-11A 52 CBE*-L*N-BPK T-2A 209 CBG*-L*N-HNN T-17A 208 CBC*-LJN-EGB T-11A 56 CBE*-L*N-BPL T-2A 209 CBG*-L*N-HPE T-17A 210 CBC*-LJN-EGC T-11A 56 CBE*-L*N-BQC T-2A 211 CBG*-L*N-HPF T-17A 210 CBC*-LJN-EGI T-11A 56 CBE*-L*N-BQD T-2A 211 CBG*-L*N-HPM T-17A 210 CBC*-LJN-EGJ T-11A 56 CBE*-L*N-BQK T-2A 211 CBG*-L*N-HPN T-17A 210 CBC*-LJN-EGK T-11A 56 CBE*-L*N-BQL T-2A 211 CBG*-L*N-HQE T-17A 212 CBC*-LJN-EJB T-11A 55 CBE*-LHN-BB8 T-2A 167 CBG*-L*N-HQF T-17A 212 CBC*-LJN-EJI T-11A 55 CBE*-LHN-BBA T-2A 167 CBG*-L*N-HQM T-17A 212 CBC*-LJN-EJJ T-11A 55 CBE*-LHN-BBB T-2A 167 CBG*-L*N-HQN T-17A 212 CBC*-LJN-XGB T-11A 63 CBE*-LHN-BBY T-2A 167 CBC*-LHN-EBA T-11A 151 CBC*-LJN-XGI T-11A 63 CBE*-LHN-BCC T-2A 52 CBC*-LHN-EBY T-11A 151 CBC*-LJN-XGJ T-11A 63 CBE*-LHN-BCD T-2A 52 CBC*-LHN-ECB T-11A 52 CBC*LJN-XVG T-11A 60 CBE*-LHN-BCI T-2A 52 CBC*-LHN-ECC T-11A 52 CBC*LJN-XVH T-11A 60 CBE*-LHN-BCJ T-2A 52 CBC*-LHN-ECH T-11A 52 CBC*LJN-XVI T-11A 60 CBE*-LHN-BGC T-2A 56 CBC*-LHN-ECI T-11A 52 CBC*-LJN-YEB T-11A 58 CBE*-LHN-BGD T-2A 56 CBC*-LHN-ECJ T-11A 52 CBC*-LJN-YEC T-11A 58 CBE*-LHN-BGI T-2A 56 CBC*-LHN-EGB T-11A 56 CBC*-LJN-YEI T-11A 58 CBE*-LHN-BGJ T-2A 56 CBC*-LHN-EGC T-11A 56 CBC*-LJN-YEJ T-11A 58 CBE*-LHN-BJ8 T-2A 178 CBC*-LHN-EGI T-11A 56 CBC*-LJN-YEK T-11A 58 CBE*-LHN-BJA T-2A 178 CBC*-LHN-EGJ T-11A 56 CBC*-LJN-YGB T-11A 61 CBE*-LHN-BJB T-2A 178 CBC*-LHN-EGK T-11A 56 CBC*-LJN-YGC T-11A 61 CBE*-LHN-BJY T-2A 178 CBC*-LHN-EJB T-11A 55 CBC*-LJN-YGI T-11A 61 CBE*-LHN-BVC T-2A 55 CBC*-LHN-EJI T-11A 55 CBC*-LJN-YGJ T-11A 61 CBE*-LHN-BVD T-2A 55 CBC*-LHN-EJJ T-11A 55 CBC*-LJN-YGK T-11A 61 CBE*-LHN-BVI T-2A 55 CBC*-LHN-XGB T-11A 63 CBC*-LJN-YVM T-11A 67 CBE*-LHN-BVJ T-2A 55 CBC*-LHN-XGI T-11A 63 CBC*-LJN-YVY T-11A 67 CBE*-LHN-XAC T-2A 60 CBC*-LHN-XGJ T-11A 63 CBC*-LJN-ZTC T-11A 66 CBE*-LHN-XAD T-2A 60 CBC*-LHN-XVG T-11A 60 CBC*-LJN-ZTN T-11A 66 CBE*-LHN-XHC T-2A 63 265 Model Code US Selected Assemblies Catalogue #999-901-192 Model Code Index ASSEMBLIES Model Code Cavity Page Model Code Cavity Page Model Code Cavity Page CBE*-LHN-XHD T-2A 63 CBE*-LJN-YHC T-2A 61 CBG*-LHN-ZDR T-17A 65 CBE*-LHN-XKD T-17A 63 CBE*-LJN-YHD T-2A 61 CBG*-LHN-ZNW T-17A 64 CBE*-LHN-XKE T-17A 63 CBE*-LJN-YHK T-2A 61 CBG*-LHN-ZNX T-19A 64 CBE*-LHN-XZQ T-19A 63 CBE*-LJN-YHL T-2A 61 CBG*-LHN-ZTJ T-17A 66 CBE*-LHN-YAB T-2A 58 CBE*-LJN-YVV T-2A 67 CBG*-LHN-ZTK T-17A 66 CBE*-LHN-YAC T-2A 58 CBE*-LJN-YVW T-2A 67 CBG*-LJN-BKA T-17A 188 CBE*-LHN-YAD T-2A 58 CBE*-LJN-ZDS T-2A 65 CBG*-LJN-BKB T-17A 188 CBE*-LHN-YAI T-2A 58 CBE*-LJN-ZNV T-2A 64 CBG*-LJN-BKY T-17A 188 CBE*-LHN-YAJ T-2A 58 CBE*-LJN-ZTF T-2A 66 CBG*-LJN-HCE T-17A 53 CBE*-LHN-YHC T-2A 61 CBE*-LJN-ZTG T-2A 66 CBG*-LJN-HCF T-17A 53 CBE*-LHN-YHD T-2A 61 CBEA-LAN-VWZ T-2A 235 CBG*-LJN-HCL T-17A 53 CBE*-LHN-YHK T-2A 61 CBEA-LAN-VZX/M T-2A 235 CBG*-LJN-HCM T-17A 53 CBE*-LHN-YHL T-2A 61 CBEA-LAN-WKH T-2A 241 CBG*-LJN-HDD T-17A 55 CBE*-LHN-YVV T-2A 67 CBEA-LAN-WKL T-2A 241 CBG*-LJN-HDE T-17A 55 CBE*-LHN-YVW T-2A 67 CBEA-LAN-WKP T-2A 242 CBG*-LJN-HDE T-17A 56 CBE*-LHN-ZDS T-2A 65 CBEA-LAN-WKS T-2A 242 CBG*-LJN-HDF T-17A 56 CBE*-LHN-ZNV T-2A 64 CBEA-LAN-WKV T-2A 242 CBG*-LJN-HDL T-17A 55 CBE*-LHN-ZTF T-2A 66 CBEA-LAN-WKY T-2A 242 CBG*-LJN-HDL T-17A 56 CBE*-LHN-ZTG T-2A 66 CBEA-LAN-XYS T-2A 234 CBG*-LJN-HDM T-17A 55 CBE*-LJN-BB8 T-2A 167 CBEA-LAN-YTC T-2A 234 CBG*-LJN-HDM T-17A 56 CBE*-LJN-BBA T-2A 167 CBEA-LAN-ZPG T-2A 233 CBG*-LJN-YJE T-17A 59 CBE*-LJN-BBB T-2A 167 CBEA-LAN-ZPI T-2A 233 CBG*-LJN-YJF T-17A 59 CBE*-LJN-BBY T-2A 167 CBEA-LAN-ZPM T-2A 233 CBG*-LJN-YJL T-17A 59 CBE*-LJN-BCC T-2A 52 CBEA-LAN-ZPO T-2A 234 CBG*-LJN-YJM T-17A 59 CBE*-LJN-BCD T-2A 52 CBG*-LHN-BKA T-17A 188 CBG*-LJN-YKE T-17A 61 CBE*-LJN-BCI T-2A 52 CBG*-LHN-BKB T-17A 188 CBG*-LJN-YKF T-17A 61 CBE*-LJN-BCJ T-2A 52 CBG*-LHN-BKY T-17A 188 CBG*-LJN-YKL T-17A 61 CBE*-LJN-BGC T-2A 56 CBG*-LHN-HCE T-17A 53 CBG*-LJN-YKM T-17A 61 CBE*-LJN-BGD T-2A 56 CBG*-LHN-HCF T-17A 53 CBG*-LJN-YVS T-17A 67 CBE*-LJN-BGI T-2A 56 CBG*-LHN-HCL T-17A 53 CBG*-LJN-YVT T-17A 67 CBE*-LJN-BGJ T-2A 56 CBG*-LHN-HCM T-17A 53 CBG*-LJN-ZDR T-17A 65 CBE*-LJN-BJ8 T-2A 178 CBG*-LHN-HDD T-17A 55 CBG*-LJN-ZNW T-17A 64 CBE*-LJN-BJA T-2A 178 CBG*-LHN-HDE T-17A 55 CBG*-LJN-ZNX T-19A 64 CBE*-LJN-BJB T-2A 178 CBG*-LHN-HDE T-17A 56 CBG*-LJN-ZTJ T-17A 66 CBE*-LJN-BJY T-2A 178 CBG*-LHN-HDF T-17A 56 CBG*-LJN-ZTK T-17A 66 CBE*-LJN-BVC T-2A 55 CBG*-LHN-HDL T-17A 55 CBI*-LHN-HBA T-19A 198 CBE*-LJN-BVD T-2A 55 CBG*-LHN-HDL T-17A 56 CBI*-LHN-HBB T-19A 198 CBE*-LJN-BVI T-2A 55 CBG*-LHN-HDM T-17A 55 CBI*-LHN-HBY T-19A 198 CBE*-LJN-BVJ T-2A 55 CBG*-LHN-HDM T-17A 56 CBI*-LHN-KCE T-19A 53 CBE*-LJN-XAC T-2A 60 CBG*-LHN-XJW T-17A 60 CBI*-LHN-KCF T-19A 53 CBE*-LJN-XAD T-2A 60 CBG*-LHN-XJX T-17A 60 CBI*-LHN-KCM T-19A 53 CBE*-LJN-XHC T-2A 63 CBG*-LHN-YJE T-17A 59 CBI*-LHN-KCN T-19A 53 CBE*-LJN-XHD T-2A 63 CBG*-LHN-YJF T-17A 59 CBI*-LHN-KG6 T-19A 57 CBE*-LJN-XKD T-17A 63 CBG*-LHN-YJL T-17A 59 CBI*-LHN-KGR T-19A 57 CBE*-LJN-XKE T-17A 63 CBG*-LHN-YJM T-17A 59 CBI*-LHN-XZZ T-11A 54 CBE*-LJN-XZQ T-19A 63 CBG*LHN-YKE T-17A 61 CBI*-LHN-YM6 T-19A 59 CBE*-LJN-YAB T-2A 58 CBG*LHN-YKF T-17A 61 CBI*-LHN-YMR T-19A 59 CBE*-LJN-YAC T-2A 58 CBG*LHN-YKL T-17A 61 CBI*-LHN-YN6 T-19A 62 CBE*-LJN-YAD T-2A 58 CBG*LHN-YKM T-17A 61 CBI*-LHN-YNR T-19A 62 CBE*-LJN-YAI T-2A 58 CBG*-LHN-YVS T-17A 67 CBI*-LHN-Z8Z T-19A 54 CBE*-LJN-YAJ T-2A 58 CBG*-LHN-YVT T-17A 67 CBI*-LHN-ZFD T-19A 65 US Selected Assemblies Catalogue #999-901-192 266 Model Code Index ASSEMBLIES Model Code Cavity Page Model Code Cavity Page Model Code Cavity Page CBI*-LJN-HBA T-19A 198 CKEB-XCN-BBA T-2A 168 CKIB-XCN-HBY T-19A 199 CBI*-LJN-HBB T-19A 198 CKEB-XCN-BBB T-2A 168 CKIB-XCN-KCE T-19A 81 CBI*-LJN-HBY T-19A 198 CKEB-XCN-BBY T-2A 168 CKIB-XCN-KCF T-19A 81 CBI*-LJN-KCE T-19A 53 CKEB-XCN-BCC T-2A 80 CKIB-XCN-KCM T-19A 81 CBI*-LJN-KCF T-19A 53 CKEB-XCN-BCD T-2A 80 CKIB-XCN-KCN T-19A 81 CBI*-LJN-KCM T-19A 53 CKEB-XCN-BCI T-2A 80 CKIB-XCN-XZZ T-19A 84 CBI*-LJN-KCN T-19A 53 CKEB-XCN-BCJ T-2A 80 CKIB-XCN-YM6 T-19A 87 CBI*-LJN-KG6 T-19A 57 CKEB-XCN-BJA T-2A 179 CKIB-XCN-Z8Z T-19A 84 CBI*-LJN-KGR T-19A 57 CKEB-XCN-BJB T-2A 179 CKIB-XCN-ZFD T-19A 90 CBI*-LJN-XZZ T-11A 54 CKEB-XCN-BJY T-2A 179 CKIB-XCN-ZNX T-19A 89 CBI*-LJN-YM6 T-19A 59 CKEB-XCN-BVC T-2A 83 CSAA-BXN-DKS T-13A 192 CBI*-LJN-YMR T-19A 59 CKEB-XCN-BVD T-2A 83 CSAA-BXN-GBS T-13A 158 CBI*-LJN-YN6 T-19A 62 CKEB-XCN-BVI T-2A 83 CSAA-BXN-IBS T-13A 202 CBI*-LJN-YNR T-19A 62 CKEB-XCN-BVJ T-2A 83 CSAA-BXN-WZY T-11A 239 CBI*-LJN-Z8Z T-19A 54 CKEB-XCN-XAC T-2A 88 CVCV-XCN-MAA T-21A 96 CBI*-LJN-ZFD T-19A 65 CKEB-XCN-XAD T-2A 88 CVCV-XCN-MAB T-21A 96 CBIA-LHN-XZP T-19A 60 CKEB-XCN-XAI T-2A 88 CVCV-XCN-MAC T-21A 96 CKBB-XCN-JCA T-163A 80 CKEB-XCN-XAJ T-2A 88 CVCV-XCN-MAI T-21A 96 CKBB-XCN-JCB T-163A 80 CKEB-XCN-YAC T-2A 86 CVCV-XCN-MAJ T-21A 96 CKBB-XCN-JCH T-163A 80 CKEB-XCN-YAD T-2A 86 CVCV-XCN-MAK T-21A 96 CKBB-XCN-JCI T-163A 80 CKEB-XCN-YAJ T-2A 86 CVCV-XCN-MBA T-21A 152 CKBB-XCN-JJA T-163A 82 CKEB-XCN-YAK T-2A 86 CVCV-XCN-MBB T-21A 152 CKBB-XCN-JJB T-163A 82 CKEB-XCN-YVV T-2A 92 CVCV-XCN-MBY T-21A 152 CKBB-XCN-JJH T-163A 82 CKEB-XCN-YVW T-2A 92 CVCV-XCN-XPA T-21A 99 CKBB-XCN-JJI T-163A 82 CKEB-XCN-ZDS T-2A 90 CVCV-XCN-XPB T-21A 99 CKBB-XCN-JYA T-163A 85 CKEB-XCN-ZNV T-2A 89 CVCV-XCN-XPC T-21A 99 CKBB-XCN-JYB T-163A 85 CKEB-XCN-ZNW T-17A 89 CVCV-XCN-XPI T-21A 99 CKBB-XCN-JYH T-163A 85 CKEB-XCN-ZTF T-2A 91 CVCV-XCN-XPJ T-21A 99 CKBB-XCN-JYI T-163A 85 CKEB-XCN-ZTG T-2A 91 CVCV-XCN-XPK T-21A 99 CKCB-XCN-EBA T-11A 152 CKGB-XCN-BKA T-17A 189 CVEV-XCN-NAB T-22A 96 CKCB-XCN-EBY T-11A 152 CKGB-XCN-BKB T-17A 189 CVEV-XCN-NAC T-22A 96 CKCB-XCN-ECB T-11A 80 CKGB-XCN-BKY T-17A 189 CVEV-XCN-NAD T-22A 96 CKCB-XCN-ECC T-11A 80 CKGB-XCN-HCE T-17A 81 CVEV-XCN-NAJ T-22A 96 CKCB-XCN-ECH T-11A 80 CKGB-XCN-HCF T-17A 81 CVEV-XCN-NAK T-22A 96 CKCB-XCN-ECI T-11A 80 CKGB-XCN-HCL T-17A 81 CVEV-XCN-XIB T-22A 99 CKCB-XCN-ECJ T-11A 80 CKGB-XCN-HCM T-17A 81 CVEV-XCN-XIC T-22A 99 CKCB-XCN-EJB T-11A 82 CKGB-XCN-HDD T-17A 83 CVEV-XCN-XID T-22A 99 CKCB-XCN-EJI T-11A 82 CKGB-XCN-HDE T-17A 83 CVEV-XCN-XII T-22A 99 CKCB-XCN-EJJ T-11A 82 CKGB-XCN-HDL T-17A 83 CVEV-XCN-XIJ T-22A 99 CKCB-XCN-XEB T-11A 88 CKGB-XCN-HDM T-17A 83 CVGV-XCN-PCD T-23A 97 CKCB-XCN-XEI T-11A 88 CKGB-XCN-YJE T-17A 87 CVGV-XCN-PCE T-23A 97 CKCB-XCN-XEJ T-11A 88 CKGB-XCN-YJF T-17A 87 CVGV-XCN-PCF T-23A 97 CKCB-XCN-YEB T-11A 85 CKGB-XCN-YJL T-17A 87 CVGV-XCN-PCL T-23A 97 CKCB-XCN-YEC T-11A 85 CKGB-XCN-YJM T-17A 87 CVGV-XCN-PCM T-23A 97 CKCB-XCN-YEI T-11A 85 CKGB-XCN-YVS T-17A 92 CVGV-XCN-XMD T-23A 100 CKCB-XCN-YEJ T-11A 85 CKGB-XCN-YVT T-17A 92 CVGV-XCN-XME T-23A 100 CKCB-XCN-YEK T-11A 85 CKGB-XCN-ZDR T-17A 90 CVGV-XCN-XMF T-23A 100 CKCB-XCN-YVM T-11A 92 CKGB-XCN-ZTJ T-17A 91 CVGV-XCN-XML T-23A 100 CKCB-XCN-YVY T-11A 92 CKGB-XCN-ZTK T-17A 91 CVGV-XCN-XMM T-23A 100 CKCB-XCN-ZTC T-11A 91 CKIB-XCN-HBA T-19A 199 CVIV-XCN-QAE T-24A 97 CKCB-XCN-ZTN T-11A 91 CKIB-XCN-HBB T-19A 199 CVIV-XCN-QAF T-24A 97 267 US Selected Assemblies Catalogue #999-901-192 Model Code Index ASSEMBLIES Model Code Cavity Page Model Code Cavity Page Model Code Cavity Page CVIV-XCN-QAM T-24A 97 CWG*-LGN-PAM T-23A 73 CXCD-X*N-GCJ T-13A 106 CVIV-XCN-QAN T-24A 97 CWG*-LGN-XME T-23A 76 CXDA-X*N-GAA T-13A 104 CVIV-XCN-XLE T-24A 100 CWG*-LGN-XMF T-23A 76 CXDA-X*N-GAB T-13A 104 CVIV-XCN-XLF T-24A 100 CWG*-LGN-XML T-23A 76 CXDA-X*N-GAH T-13A 104 CVIV-XCN-Z9T T-24A 98 CWG*-LGN-XMM T-23A 76 CXDA-X*N-GAI T-13A 104 CWC*-LGN-MAB T-21A 72 CWG*-LHN-PAE T-23A 73 CXDA-X*N-GAJ T-13A 104 CWC*-LGN-MAC T-21A 72 CWG*-LHN-PAF T-23A 73 CXDA-X*N-GCA T-13A 106 CWC*-LGN-MAI T-21A 72 CWG*-LHN-PAL T-23A 73 CXDA-X*N-GCB T-13A 106 CWC*-LGN-MAJ T-21A 72 CWG*-LHN-PAM T-23A 73 CXDA-X*N-GCI T-13A 106 CWC*-LGN-MAK T-21A 72 CWG*-LHN-XME T-23A 76 CXDA-X*N-GCJ T-13A 106 CWC*-LGN-MBA T-21A 151 CWG*-LHN-XMF T-23A 76 CXDA-X*N-GDA T-13A / T-5A 153 CWC*-LGN-MBB T-21A 151 CWG*-LHN-XML T-23A 76 CXDA-X*N-GDP T-13A / T-5A 153 CWC*-LGN-MBY T-21A 151 CWG*-LHN-XMM T-23A 76 CXDA-X*N-GDW T-13A / T-5A 153 CWC*-LGN-XPB T-21A 75 CWI*- LHN-XLE T-24A 76 CXDA-X*N-GDY T-13A / T-5A 153 CWC*-LGN-XPC T-21A 75 CWI*- LHN-XLF T-24A 76 CXED-X*N-DAB T-5A 104 CWC*-LGN-XPI T-21A 75 CWI*-LFN-QCE T-24A 73 CXED-X*N-DAC T-5A 104 CWC*-LGN-XPJ T-21A 75 CWI*-LFN-QCF T-24A 73 CXED-X*N-DAJ T-5A 104 CWC*-LGN-XPK T-21A 75 CWI*-LFN-QCM T-24A 73 CXED-X*N-DAK T-5A 104 CWC*-LHN-MAB T-21A 72 CWI*-LFN-QCN T-24A 73 CXED-X*N-DCB T-5A 106 CWC*-LHN-MAC T-21A 72 CWI*-LFN-XLE T-24A 76 CXED-X*N-DCC T-5A 106 CWC*-LHN-MAI T-21A 72 CWI*-LFN-XLF T-24A 76 CXED-X*N-DCI T-5A 106 CWC*-LHN-MAJ T-21A 72 CWI*-LFN-Z9T T-24A 74 CXED-X*N-DCJ T-5A 106 CWC*-LHN-MAK T-21A 72 CWI*-LHN-QCE T-24A 73 CXED-X*N-DCK T-5A 106 CWC*-LHN-MBA T-21A 151 CWI*-LHN-QCF T-24A 73 CXFA-X*N-DAB T-5A 104 CWC*-LHN-MBB T-21A 151 CWI*-LHN-QCM T-24A 73 CXFA-X*N-DAC T-5A 104 CWC*-LHN-MBY T-21A 151 CWI*-LHN-QCN T-24A 73 CXFA-X*N-DAJ T-5A 104 CWC*-LHN-XPB T-21A 75 CWI*-LHN-Z9T T-24A 74 CXFA-X*N-DAK T-5A 104 CWC*-LHN-XPC T-21A 75 CXAD-X*N-AAA T-162A 104 CXFA-X*N-DCB T-5A 106 CWC*-LHN-XPI T-21A 75 CXAD-X*N-AAB T-162A 104 CXFA-X*N-DCC T-5A 106 CWC*-LHN-XPJ T-21A 75 CXAD-X*N-AAH T-162A 104 CXFA-X*N-DCI T-5A 106 CWC*-LHN-XPK T-21A 75 CXAD-X*N-AAI T-162A 104 CXFA-X*N-DCJ T-5A 106 CWE*-LFN-NAC T-22A 72 CXAD-X*N-ACA T-162A 106 CXFA-X*N-DCK T-5A 06 CWE*-LFN-NAD T-22A 72 CXAD-X*N-ACB T-162A 106 CXFA-X*N-GDF T-13A 153 CWE*-LFN-NAJ T-22A 72 CXAD-X*N-ACH T-162A 106 CXFA-XAN-DBW T-5A 169 CWE*-LFN-NAK T-22A 72 CXAD-X*N-ACI T-162A 106 CXFA-XAN-DJW T-5A 180 CWE*-LFN-XIC T-22A 75 CXBA-X*N-AAA T-162A 104 CXFA-XCN-DBJ T-5A 169 CWE*-LFN-XID T-22A 75 CXBA-X*N-AAB T-162A 104 CXFA-XCN-DBK T-5A 169 CWE*-LFN-XII T-22A 75 CXBA-X*N-AAH T-162A 104 CXFA-XCN-DBP T-5A 169 CWE*-LFN-XIJ T-22A 75 CXBA-X*N-AAI T-162A 104 CXFA-XCN-DJJ T-5A 180 CWE*-LHN-NAC T-22A 72 CXBA-X*N-ACA T-162A 106 CXFA-XCN-DJK T-5A 180 CWE*-LHN-NAD T-22A 72 CXBA-X*N-ACB T-162A 106 CXFA-XCN-DJP T-5A 180 CWE*-LHN-NAJ T-22A 72 CXBA-X*N-ACH T-162A 106 CXGD-X*N-IAD T-16A 105 CWE*-LHN-NAK T-22A 72 CXBA-X*N-ACI T-162A 106 CXGD-X*N-IAE T-16A 105 CWE*-LHN-XIC T-22A 75 CXCD-X*N-GAA T-13A 104 CXGD-X*N-IAF T-16A 105 CWE*-LHN-XID T-22A 75 CXCD-X*N-GAB T-13A 104 CXGD-X*N-IAL T-16A 105 CWE*-LHN-XIE T-22A 75 CXCD-X*N-GAH T-13A 104 CXGD-X*N-IAM T-16A 105 CWE*-LHN-XII T-22A 75 CXCD-X*N-GAI T-13A 104 CXGD-X*N-ICD T-16A 107 CWE*-LHN-XIJ T-22A 75 CXCD-X*N-GAJ T-13A 104 CXGD-X*N-ICE T-16A 107 CWG*-LGN-PAE T-23A 73 CXCD-X*N-GCA T-13A 106 CXGD-X*N-ICF T-16A 107 CWG*-LGN-PAF T-23A 73 CXCD-X*N-GCB T-13A 106 CXGD-X*N-ICL T-16A 107 CWG*-LGN-PAL T-23A 73 CXCD-X*N-GCI T-13A 106 CXGD-X*N-ICM T-16A 107 US Selected Assemblies Catalogue #999-901-192 268 Model Code Index ASSEMBLIES Model Code Cavity Page Model Code Cavity Page Model Code Cavity Page CXHA-X*N-IAD T-16A 105 FCCB-LAN-GCH T-13A 122 FDCB-LAN-DAC T-5A 128 CXHA-X*N-IAE T-16A 105 FCCB-LAN-GCI T-13A 122 FDCB-LAN-DAI T-5A 128 CXHA-X*N-IAF T-16A 105 FCCB-LAN-GCJ T-13A 122 FDCB-LAN-DAJ T-5A 128 CXHA-X*N-IAL T-16A 105 FCCB-LAN-XWT T-13A 231 FDCB-LAN-DAK T-5A 128 CXHA-X*N-IAM T-16A 105 FCDB-LAN-DAA T-5A 120 FDCB-LAN-DAW T-5A 128 CXHA-X*N-ICD T-16A 107 FCDB-LAN-DAB T-5A 120 FDCB-LAN-DBA T-5A 170 CXHA-X*N-ICE T-16A 107 FCDB-LAN-DAC T-5A 120 FDCB-LAN-DBB T-5A 170 CXHA-X*N-ICF T-16A 107 FCDB-LAN-DAI T-5A 120 FDCB-LAN-DBC T-5A 170 CXHA-X*N-ICL T-16A 107 FCDB-LAN-DAJ T-5A 120 FDCB-LAN-DBP T-5A 170 CXHA-X*N-ICM T-16A 107 FCDB-LAN-DAK T-5A 120 FDCB-LAN-DBY T-5A 170 CXHA-XAN-CDV T-16A 200 FCDB-LAN-DCB T-5A 122 FDCB-LAN-DCB T-5A 130 CXHA-XAN-DKX T-16A 190 FCDB-LAN-DCC T-5A 122 FDCB-LAN-DCC T-5A 130 CXHA-XCN-DKP T-16A 190 FCDB-LAN-DCI T-5A 122 FDCB-LAN-DCI T-5A 130 CXHA-XCN-DKT T-16A 190 FCDB-LAN-DCJ T-5A 122 FDCB-LAN-DCJ T-5A 130 CXHA-XCN-DKZ T-16A 190 FCDB-LAN-DCK T-5A 122 FDCB-LAN-DCK T-5A 130 CXID-X*N-VTN T-18A 108 FCEB-LAN-IAD T-16A 121 FDCB-LAN-DJA T-5A 181 CXID-X*N-LAD T-18A 105 FCEB-LAN-IAE T-16A 121 FDCB-LAN-DJB T-5A 181 CXID-X*N-LAE T-18A 105 FCEB-LAN-IAF T-16A 121 FDCB-LAN-DJP T-5A 181 CXID-X*N-LAF T-18A 105 FCEB-LAN-IAL T-16A 121 FDCB-LAN-DJY T-5A 181 CXID-X*N-LAL T-18A 105 FCEB-LAN-IAM T-16A 121 FDCB-LAN-WVA T-5A 240 CXID-X*N-LAM T-18A 105 FCEB-LAN-ICD T-16A 123 FDCB-LAN-WXH T-5A 240 CXID-X*N-ZLR T-18A 107 FCEB-LAN-ICE T-16A 123 FDCB-LAN-WZB T-5A 240 CXID-X*N-ZLS T-18A 107 FCEB-LAN-ICF T-16A 123 FDEA-LAN-DKA T-16A 191 CXID-X*N-XZY T-18A 108 FCEB-LAN-ICL T-16A 123 FDEA-LAN-DKB T-16A 191 CXJA-X*N-LAD T-18A 105 FCEB-LAN-ICM T-16A 123 FDEA-LAN-DKP T-16A 191 CXJA-X*N-LAE T-18A 105 FCFB-LAN-LAD T-18A 121 FDEA-LAN-DKY T-16A 191 CXJA-X*N-LAF T-18A 105 FCFB-LAN-LAE T-18A 121 FDEA-LAN-DKZ T-16A 191 CXJA-X*N-LAL T-18A 105 FCFB-LAN-LAF T-18A 121 FDEA-LAN-IAD T-16A 129 CXJA-X*N-LAM T-18A 105 FCFB-LAN-LAL T-18A 121 FDEA-LAN-IAE T-16A 129 CXJA-X*N-VTN T-18A 108 FCFB-LAN-LAM T-18A 121 FDEA-LAN-IAF T-16A 129 CXJA-X*N-XZY T-18A 108 FCFB-LAN-VTN T-18A 124 FDEA-LAN-IAL T-16A 129 CXJA-X*N-ZLR T-18A 107 FCFB-LAN-XZY T-18A 124 FDEA-LAN-IAM T-16A 129 CXJA-X*N-ZLS T-18A 107 FCFB-LAN-ZLR T-18A 123 FDEA-LAN-ICD T-16A 131 CXJA-XCN-IBO T-18A 200 FCFB-LAN-ZLS T-18A 123 FDEA-LAN-ICE T-16A 131 CXJA-XCN-IBV T-18A 200 FDBA-LAN-GAA T-13A 128 FDEA-LAN-ICF T-16A 131 CXJA-XCN-IBZ T-18A 200 FDBA-LAN-GAB T-13A 128 FDEA-LAN-ICL T-16A 131 FCBB-LAN-AAA T-162A 120 FDBA-LAN-GAH T-13A 128 FDEA-LAN-ICM T-16A 131 FCBB-LAN-AAB T-162A 120 FDBA-LAN-GAI T-13A 128 FDFA-LAN-IBE T-18A 201 FCBB-LAN-AAH T-162A 120 FDBA-LAN-GAJ T-13A 128 FDFA-LAN-IBF T-18A 201 FCBB-LAN-AAI T-162A 120 FDBA-LAN-GBA T-13A 155 FDFA-LAN-IBO T-18A 201 FCBB-LAN-ACA T-162A 122 FDBA-LAN-GBP T-13A 154 FDFA-LAN-IBY T-18A 201 FCBB-LAN-ACB T-162A 122 FDBA-LAN-GBW T-13A 155 FDFA-LAN-IBZ T-18A 201 FCBB-LAN-ACH T-162A 122 FDBA-LAN-GBX T-13A 155 FDFA-LAN-LAD T-18A 129 FCBB-LAN-ACI T-162A 122 FDBA-LAN-GBY T-13A 155 FDFA-LAN-LAE T-18A 129 FCCB-LAN-GAA T-13A 120 FDBA-LAN-GCA T-13A 130 FDFA-LAN-LAF T-18A 129 FCCB-LAN-GAB T-13A 120 FDBA-LAN-GCB T-13A 130 FDFA-LAN-LAL T-18A 129 FCCB-LAN-GAH T-13A 120 FDBA-LAN-GCH T-13A 130 FDFA-LAN-LAM T-18A 129 FCCB-LAN-GAI T-13A 120 FDBA-LAN-GCI T-13A 130 FDFA-LAN-VTN T-18A 132 FCCB-LAN-GAJ T-13A 120 FDBA-LAN-GCJ T-13A 130 FDFA-LAN-XZY T-18A 132 FCCB-LAN-GCA T-13A 122 FDCB-LAN-DAA T-5A 128 FDFA-LAN-ZLR T-18A 131 FCCB-LAN-GCB T-13A 122 FDCB-LAN-DAB T-5A 128 FDFA-LAN-ZLS T-18A 131 269 US Selected Assemblies Catalogue #999-901-192 Model Code Index ASSEMBLIES Model Code Cavity Page Model Code Cavity Page Model Code Cavity Page FRBA-LAN-JCA T-163A 136 FXEA-LAN-IAD T-16A 121 NCEB-L*N-DCK T-5A 114 FRBA-LAN-JCB T-163A 136 FXEA-LAN-IAE T-16A 121 NCEB-LAN-DBA T-5A 170 FRBA-LAN-JCH T-163A 136 FXEA-LAN-IAF T-16A 121 NCEB-LAN-DBB T-5A 170 FRBA-LAN-JCI T-163A 136 FXEA-LAN-IAL T-16A 121 NCEB-LAN-DBC T-5A 170 FRCA-LAN-EAB T-11A 136 FXEA-LAN-IAM T-16A 121 NCEB-LAN-DBY T-5A 170 FRCA-LAN-EAC T-11A 136 FXEA-LAN-ICD T-16A 123 NCEB-LCN-DJA T-5A 181 FRCA-LAN-EAJ T-11A 136 FXEA-LAN-ICE T-16A 123 NCEB-LCN-DJB T-5A 181 FRCA-LAN-EAK T-11A 136 FXEA-LAN-ICF T-16A 123 NCEB-LCN-DJY T-5A 181 FRCA-LAN-WBN T-11A 154 FXEA-LAN-ICL T-16A 123 NCFB-L*N-DKA T-16A 191 FRDA-LAN-BAB T-2A 136 FXEA-LAN-ICM T-16A 123 NCFB-L*N-DKB T-16A 191 FRDA-LAN-BAC T-2A 136 FXFA-LAN-LAD T-18A 121 NCFB-L*N-IAD T-16A 113 FRDA-LAN-BAD T-2A 136 FXFA-LAN-LAE T-18A 121 NCFB-L*N-IAE T-16A 113 FRDA-LAN-BAJ T-2A 136 FXFA-LAN-LAF T-18A 121 NCFB-L*N-IAF T-16A 113 FRDA-LAN-BAK T-2A 136 FXFA-LAN-LAL T-18A 121 NCFB-L*N-IAL T-16A 113 FRDA-LAN-BAL T-2A 136 FXFA-LAN-LAM T-18A 121 NCFB-L*N-IAM T-16A 113 FREA-LAN-HED T-17A 137 FXFA-LAN-VTN T-18A 124 NCFB-L*N-ICD T-16A 115 FREA-LAN-HEE T-17A 137 FXFA-LAN-XZY T-18A 124 NCFB-L*N-ICE T-16A 115 FREA-LAN-HEF T-17A 137 FXFA-LAN-ZLR T-18A 123 NCFB-L*N-ICF T-16A 115 FREA-LAN-HEL T-17A 137 FXFA-LAN-ZLS T-18A 123 NCFB-L*N-ICL T-16A 115 FREA-LAN-HEM T-17A 137 NCBB-L*N-AAA T-162A 112 NCFB-L*N-ICM T-16A 115 FRFA-LAN-KEE T-19A 137 NCBB-L*N-AAB T-162A 112 NCGB-L*N-LAD T-18A 113 FRFA-LAN-KEF T-19A 137 NCBB-L*N-AAH T-162A 112 NCGB-L*N-LAE T-18A 113 FXBA-LAN-AAA T-162A 120 NCBB-L*N-AAI T-162A 112 NCGB-L*N-LAF T-18A 113 FXBA-LAN-AAB T-162A 120 NCBB-L*N-ACA T-162A 114 NCGB-L*N-LAL T-18A 113 FXBA-LAN-AAH T-162A 120 NCBB-L*N-ACB T-162A 114 NCGB-L*N-LAM T-18A 113 FXBA-LAN-AAI T-162A 120 NCBB-L*N-ACH T-162A 114 NCGB-L*N-VTN T-18A 116 FXBA-LAN-ACA T-162A 122 NCBB-L*N-ACI T-162A 114 NCGB-L*N-XZY T-18A 116 FXBA-LAN-ACB T-162A 122 NCCB-L*N-GAA T-13A 112 NCGB-L*N-ZLR T-18A 115 FXBA-LAN-ACH T-162A 122 NCCB-L*N-GAB T-13A 112 NCGB-L*N-ZLS T-18A 115 FXBA-LAN-ACI T-162A 122 NCCB-L*N-GAH T-13A 112 NCGB-LCN-IBE T-18A 201 FXCA-LAN-GAA T-13A 120 NCCB-L*N-GAI T-13A 112 NCGB-LCN-IBF T-18A 201 FXCA-LAN-GAB T-13A 120 NCCB-L*N-GAJ T-13A 112 NCGB-LCN-IBY T-18A 201 FXCA-LAN-GAH T-13A 120 NCCB-L*N-GCA T-13A 114 NCGB-LCN-IBZ T-18A 201 FXCA-LAN-GAI T-13A 120 NCCB-L*N-GCB T-13A 114 NFBC-L*N-AAA T-162A 112 FXCA-LAN-GAJ T-13A 120 NCCB-L*N-GCH T-13A 114 NFBC-L*N-AAB T-162A 112 FXCA-LAN-GCA T-13A 122 NCCB-L*N-GCI T-13A 114 NFBC-L*N-AAH T-162A 112 FXCA-LAN-GCB T-13A 122 NCCB-L*N-GCJ T-13A 114 NFBC-L*N-AAI T-162A 112 FXCA-LAN-GCH T-13A 122 NCCB-LAN-GBW T-13A 155 NFBC-L*N-ACA T-162A 114 FXCA-LAN-GCI T-13A 122 NCCB-LAN-GBX T-13A 155 NFBC-L*N-ACB T-162A 114 FXCA-LAN-GCJ T-13A 122 NCCB-LCN-GBA T-13A 155 NFBC-L*N-ACH T-162A 114 FXDA-LAN-DAA T-5A 120 NCCB-LCN-GBY T-13A 155 NFBC-L*N-ACI T-162A 114 FXDA-LAN-DAB T-5A 120 NCEB-L*N-DAA T-5A 112 NFCB-L*N-DKY T-16A 191 FXDA-LAN-DAC T-5A 120 NCEB-L*N-DAB T-5A 112 NFCB-L*N-DKZ T-16A 191 FXDA-LAN-DAI T-5A 120 NCEB-L*N-DAC T-5A 112 NFCC-L*N-GAA T-13A 112 FXDA-LAN-DAJ T-5A 120 NCEB-L*N-DAI T-5A 112 NFCC-L*N-GAB T-13A 112 FXDA-LAN-DAK T-5A 120 NCEB-L*N-DAJ T-5A 112 NFCC-L*N-GAH T-13A 112 FXDA-LAN-DCB T-5A 122 NCEB-L*N-DAK T-5A 112 NFCC-L*N-GAI T-13A 112 FXDA-LAN-DCC T-5A 122 NCEB-L*N-DCB T-5A 114 NFCC-L*N-GAJ T-13A 112 FXDA-LAN-DCI T-5A 122 NCEB-L*N-DCC T-5A 114 NFCC-L*N-GCA T-13A 114 FXDA-LAN-DCJ T-5A 122 NCEB-L*N-DCI T-5A 114 NFCC-L*N-GCB T-13A 114 FXDA-LAN-DCK T-5A 122 NCEB-L*N-DCJ T-5A 114 NFCC-L*N-GCH T-13A 114 US Selected Assemblies Catalogue #999-901-192 270 Model Code Index ASSEMBLIES Model Code Cavity Page Model Code Cavity Page Model Code Cavity NFCC-L*N-GCI T-13A 114 PBDB-LAN-E6C T-11A 39 PBJB-LAN-K2* T-19A 40 NFCC-L*N-GCJ T-13A 114 PBDB-LAN-E6I T-11A 39 PBJB-LAN-KF6 T-19-A 38 NFCC-LAN-DBS T-13A 171 PBDB-LAN-E6J T-11A 39 PBJB-LAN-KFE T-19-A 37 NFCC-LCN-DJS T-13A 182 PBDB-LAN-EB2 T-11A 149 PBJB-LAN-KFF T-19-A 37 NFCC-LCN-GBP T-13A 154 PBDB-LAN-EB3 T-11A 149 PBJB-LAN-KFR T-19-A 38 NFCC-LCN-GBS T-13A 154 PBDB-LAN-EBA T-11A 149 PPDB-LAN-E4B T-11A 47 NFCC-LCN-GBW T-13A 154 PBDB-LAN-EBP T-11A 149 PPDB-LAN-E4C T-11A 47 NFCC-LCN-GBX T-13A 154 PBDB-LAN-EBY T-11A 149 PPDB-LAN-E4I T-11A 47 NFCC-LCN-ZFZ T-13A 232 PBDB-LAN-EFB T-11A 36 PPDB-LAN-E4J T-11A 47 NFDC-L*N-DAA T-5A 112 PBDB-LAN-EFC T-11A 36 PPDB-LAN-E4K T-11A 47 NFDC-L*N-DAB T-5A 112 PBDB-LAN-EFH T-11A 36 PPDB-LAN-EB2 T-11A 150 NFDC-L*N-DAC T-5A 112 PBDB-LAN-EFI T-11A 36 PPDB-LAN-EB3 T-11A 150 NFDC-L*N-DAI T-5A 112 PBDB-LAN-EFJ T-11A 36 PPDB-LAN-EBA T-11A 150 NFDC-L*N-DAJ T-5A 112 PBFB-LAN-B6B T-2A 39 PPDB-LAN-EBP T-11A 150 NFDC-L*N-DAK T-5A 112 PBFB-LAN-B6C T-2A 39 PPDB-LAN-EBY T-11A 150 NFDC-L*N-DCB T-5A 114 PBFB-LAN-B6D T-2A 39 PPDB-LAN-ELB T-11A 44 NFDC-L*N-DCC T-5A 114 PBFB-LAN-B6I T-2A 39 PPDB-LAN-ELC T-11A 44 NFDC-L*N-DCI T-5A 114 PBFB-LAN-B6J T-2A 39 PPDB-LAN-ELI T-11A 44 NFDC-L*N-DCJ T-5A 114 PBFB-LAN-BB2 T-2A 165 PPDB-LAN-ELJ T-11A 44 NFDC-L*N-DCK T-5A 114 PBFB-LAN-BB3 T-2A 165 PPDB-LAN-ELK T-11A 44 NFDC-LAN-DBP T-5A 170 PBFB-LAN-BBA T-2A 165 PPFB-LAN-B4C T-2A 47 NFDC-LAN-DJP T-5A 181 PBFB-LAN-BBB T-2A 165 PPFB-LAN-B4D T-2A 47 NFEC-L*N-IAD T-16A 113 PBFB-LAN-BBP T-2A 165 PPFB-LAN-B4J T-2A 47 NFEC-L*N-IAE T-16A 113 PBFB-LAN-BFC T-2A 36 PPFB-LAN-B4K T-2A 47 NFEC-L*N-IAF T-16A 113 PBFB-LAN-BFD T-2A 36 PPFB-LAN-BB2 T-2A 166 NFEC-L*N-IAL T-16A 113 PBFB-LAN-BFH T-2A 36 PPFB-LAN-BB3 T-2A 166 NFEC-L*N-IAM T-16A 113 PBFB-LAN-BFI T-2A 36 PPFB-LAN-BBP T-2A 166 NFEC-L*N-ICD T-16A 115 PBFB-LAN-BJ2 T-2A 176 PPFB-LAN-BJ2 T-2A 177 NFEC-L*N-ICE T-16A 115 PBFB-LAN-BJ3 T-2A 176 PPFB-LAN-BJ3 T-2A 177 NFEC-L*N-ICF T-16A 115 PBFB-LAN-BJA T-2A 176 PPFB-LAN-BJA T-2A 177 NFEC-L*N-ICL T-16A 115 PBFB-LAN-BJB T-2A 176 PPFB-LAN-BJB T-2A 177 NFEC-L*N-ICM T-16A 115 PBFB-LAN-BJP T-2A 176 PPFB-LAN-BJP T-2A 177 NFEC-LEN-DKP T-16A 191 PBHB-LAN-BK2 T-17A 186 PPFB-LAN-BLC T-2A 44 NFFC-L*N-LAD T-18A 113 PBHB-LAN-BKA T-17A 186 PPFB-LAN-BLD T-2A 44 NFFC-L*N-LAE T-18A 113 PBHB-LAN-BKB T-17A 186 PPFB-LAN-BLI T-2A 44 NFFC-L*N-LAF T-18A 113 PBHB-LAN-BKJ T-17A 186 PPFB-LAN-BLJ T-2A 44 NFFC-L*N-LAL T-18A 113 PBHB-LAN-BKP T-17A 186 PPFB-LAN-BLK T-2A 44 NFFC-L*N-LAM T-18A 113 PBHB-LAN-H2* T-17A 40 PPHB-LAN-BK2 T-17A 187 NFFC-L*N-VTN T-18A 116 PBHB-LAN-H2* T-17A 40 PPHB-LAN-BKA T-17A 187 NFFC-L*N-XZY T-18A 116 PBHB-LAN-H2* T-17A 40 PPHB-LAN-BKB T-17A 187 NFFC-L*N-ZLR T-18A 115 PBHB-LAN-H2* T-17A 40 PPHB-LAN-BKJ T-17A 187 NFFC-L*N-ZLS T-18A 115 PBHB-LAN-HBJ T-17A 196 PPHB-LAN-BKP T-17A 187 NFFC-LGN-IBO T-18A 201 PBHB-LAN-HBK T-17A 196 PPHB-LAN-H4E T-17A 48 PBBB-LAN-J2A T-163A 39 PBHB-LAN-HFE T-17A 37 PPHB-LAN-H4F T-17A 48 PBBB-LAN-J2B T-163A 39 PBHB-LAN-HFF T-17A 37 PPHB-LAN-H4L T-17A 48 PBBB-LAN-J2H T-163A 39 PBHB-LAN-HFL T-17A 37 PPHB-LAN-H4M T-17A 48 PBBB-LAN-J2I T-163A 39 PBHB-LAN-HFM T-17A 37 PPHB-LAN-HBJ T-17A 197 PBBB-LAN-JFB T-163A 36 PBJB-LAN-HBA T-19A 196 PPHB-LAN-HBK T-17A 197 PBBB-LAN-JFH T-163A 36 PBJB-LAN-HBB T-19A 196 PPHB-LAN-HEE T-17A 45 PBBB-LAN-JFI T-163A 36 PBJB-LAN-HBO T-19A 196 PPHB-LAN-HEF T-17A 45 PBDB-LAN-E6B T-11A 39 PBJB-LAN-K2* T-19A 40 PPHB-LAN-HEL T-17A 45 271 Page US Selected Assemblies Catalogue #999-901-192 Model Code Index ASSEMBLIES Model Code Cavity Page Model Code Cavity Page Model Code Cavity Page PPHB-LAN-HEM T-17A 45 PRHB-LAN-H4L T-17A 48 RDDA-LAN-FAD T-10A 4 PPJB-LAN-HBA T-19A 197 PRHB-LAN-H4M T-17A 48 RDDA-LAN-FAK T-10A 4 PPJB-LAN-HBB T-19A 197 PRHB-LAN-HBJ T-17A 197 RDDA-LAN-FAL T-10A 4 PPJB-LAN-HBO T-19A 197 PRHB-LAN-HBK T-17A 197 RDDA-LAN-FBA T-10A 146 PPJB-LAN-K4E T-19A 48 PRHB-LAN-HEE T-17A 45 RDDA-LAN-FBC T-10A 146 PPJB-LAN-K4F T-19A 48 PRHB-LAN-HEF T-17A 45 RDDA-LAN-FBP T-10A 146 PPJB-LAN-KE6 T-19A 46 PRHB-LAN-HEL T-17A 45 RDDA-LAN-FBX T-10A 146 PPJB-LAN-KEE T-19A 45 PRHB-LAN-HEM T-17A 45 RDDA-LAN-FBY T-10A 146 PPJB-LAN-KEF T-19A 45 PRJB-LAN-HBA T-19A 197 RDDA-LAN-FEB T-10A 6 PPJB-LAN-KEM T-19A 45 PRJB-LAN-HBB T-19A 197 RDDA-LAN-FEC T-10A 6 PPJB-LAN-KEN T-19A 45 PRJB-LAN-HBO T-19A 197 RDDA-LAN-FEI T-10A 6 PPJB-LAN-KER T-19A 46 PRJB-LAN-K4E T-19A 48 RDDA-LAN-FEJ T-10A 6 PRDB-LAN-E4B T-11A 47 PRJB-LAN-K4F T-19A 48 RDDA-LAN-FRB T-10A 145 PRDB-LAN-E4C T-11A 47 PRJB-LAN-KE6 T-19A 46 RDDA-LAN-FRC T-10A 161 PRDB-LAN-E4I T-11A 47 PRJB-LAN-KEE T-19A 45 RDDA-LAN-FRJ T-10A 145 PRDB-LAN-E4J T-11A 47 PRJB-LAN-KEF T-19A 45 RDDA-LAN-FRK T-10A 161 PRDB-LAN-E4K T-11A 47 PRJB-LAN-KEM T-19A 45 RDDA-LAN-FSB T-10A 145 PRDB-LAN-EB2 T-11A 150 PRJB-LAN-KEN T-19A 45 RDDA-LAN-FSC T-10A 161 PRDB-LAN-EB3 T-11A 150 PRJB-LAN-KER T-19A 46 RDDA-LAN-FSJ T-10A 145 PRDB-LAN-EBA T-11A 150 RDBA-LAN-AAA T-162A 4 RDDA-LAN-FSK T-10A 161 PRDB-LAN-EBP T-11A 150 RDBA-LAN-AAB T-162A 4 RDDA-LAN-FTC T-10A 161 PRDB-LAN-EBY T-11A 150 RDBA-LAN-AAH T-162A 4 RDDA-LAN-FTK T-10A 161 PRDB-LAN-ELB T-11A 44 RDBA-LAN-AAI T-162A 4 RDDA-LAN-YFB T-10A 9 PRDB-LAN-ELC T-11A 44 RDBA-LAN-AEA T-162A 6 RDDA-LAN-YFC T-10A 9 PRDB-LAN-ELI T-11A 4 RDBA-LAN-AEB T-162A 6 RDDA-LAN-YFI T-10A 9 PRDB-LAN-ELJ T-11A 44 RDBA-LAN-AEH T-162A 6 RDDA-LAN-YFJ T-10A 9 PRDB-LAN-ELK T-11A 44 RDBA-LAN-AEI T-162A 6 RDDA-LAN-ZHH T-10A 173 PRFB-LAN-B4C T-2A 47 RDBA-LAN-AYA T-162A 9 RDDA-LAN-ZHJ T-10A 173 PRFB-LAN-B4D T-2A 47 RDBA-LAN-AYB T-162A 9 RDDA-LAN-ZHK T-10A 173 PRFB-LAN-B4J T-2A 47 RDBA-LAN-AYH T-162A 9 RDDA-LAN-ZHL T-10A 173 PRFB-LAN-B4K T-2A 47 RDBA-LAN-AYI T-162A 9 RDDA-LAN-ZHP T-10A 173 PRFB-LAN-BB2 T-2A 166 RDDA-L*N-WLL T-10A 241 RDDA-LAN-ZHQ T-10A 173 PRFB-LAN-BB3 T-2A 166 RDDA-L*N-WLY T-10A 241 RDDA-LAN-ZHR T-10A 173 PRFB-LAN-BBP T-2A 166 RDDA-L*N-WMV T-10A 241 RDDA-LAN-ZHS T-10A 173 PRFB-LAN-BJ2 T-2A 177 RDDA-L*N-WVP T-10A 238 RDFA-LAN-CAC T-3A 4 PRFB-LAN-BJ3 T-2A 177 RDDA-L*N-WVS T-10A 238 RDFA-LAN-CAD T-3A 4 PRFB-LAN-BJA T-2A 177 RDDA-L*N-WVY T-10A 238 RDFA-LAN-CAH T-3A 4 PRFB-LAN-BJB T-2A 177 RDDA-L*N-YVP T-10A 235 RDFA-LAN-CAI T-3A 4 PRFB-LAN-BJP T-2A 177 RDDA-L*N-YWA T-10A 233 RDFA-LAN-CEJ T-3A 6 PRFB-LAN-BLC T-2A 44 RDDA-L*N-YXB T-10A 230 RDFA-LAN-CEL T-3A 6 PRFB-LAN-BLD T-2A 44 RDDA-L*N-ZFK T-10A 230 RDFA-LAN-CJA T-3A 174 PRFB-LAN-BLI T-2A 44 RDDA-L*N-ZFK T-10A 230 RDFA-LAN-CJB T-3A 174 PRFB-LAN-BLJ T-2A 44 RDDA-LAN-CBD T-10A 162 RDFA-LAN-CJP T-3A 174 PRFB-LAN-BLK T-2A 44 RDDA-LAN-CBE T-10A 162 RDFA-LAN-CJX T-3A 174 PRHB-LAN-BK2 T-17A 187 RDDA-LAN-CBF T-10A 162 RDFA-LAN-CKA T-3A 184 PRHB-LAN-BKA T-17A 187 RDDA-LAN-CBG T-10A 162 RDFA-LAN-CKB T-3A 184 PRHB-LAN-BKB T-17A 187 RDDA-LAN-CBH T-10A 163 RDFA-LAN-CKP T-3A 184 PRHB-LAN-BKJ T-17A 187 RDDA-LAN-CBI T-10A 162 RDFA-LAN-CKX T-3A 184 PRHB-LAN-BKP T-17A 187 RDDA-LAN-CJY T-10A 174 RDFA-LAN-CRE T-3A 193 PRHB-LAN-H4E T-17A 48 RDDA-LAN-CKY T-10A 184 RDFA-LAN-CRM T-3A 193 PRHB-LAN-H4F T-17A 48 RDDA-LAN-FAC T-10A 4 RDFA-LAN-CSE T-3A 193 US Selected Assemblies Catalogue #999-901-192 272 Model Code Index ASSEMBLIES Model Code Cavity Page Model Code Cavity Page Model Code Cavity Page RDFA-LAN-CSM T-3A 193 RPCC-LAN-AYH T-162A 9 RPGC-LAN-CJA T-3A 174 RDFA-LAN-CTE T-3A 193 RPCC-LAN-AYI T-162A 9 RPGC-LAN-CJB T-3A 174 RDFA-LAN-CTM T-3A 193 RPEC-LAN-CBD T-10A 162 RPGC-LAN-CJP T-3A 174 RDFA-LAN-VTE T-3A 183 RPEC-LAN-CBE T-10A 162 RPGC-LAN-CJX T-3A 174 RDFA-LAN-YCD T-3A 9 RPEC-LAN-CBF T-10A 162 RPGC-LAN-CKA T-3A 184 RDFA-LAN-YCE T-3A 9 RPEC-LAN-CBG T-10A 162 RPGC-LAN-CKB T-3A 184 RDFA-LAN-YCL T-3A 9 RPEC-LAN-CBH T-10A 163 RPGC-LAN-CKP T-3A 184 RDFA-LAN-YCM T-3A 9 RPEC-LAN-CBI T-10A 162 RPGC-LAN-CKX T-3A 184 RDFA-LAN-ZLF T-3A 183 RPEC-LAN-CJY T-10A 174 RPGC-LAN-CRE T-3A 193 RDFA-LAN-ZLW T-3A 183 RPEC-LAN-CKY T-10A 184 RPGC-LAN-CRM T-3A 193 RDFA-LAN-ZLX T-3A 183 RPEC-LAN-FAC T-10A 4 RPGC-LAN-CSE T-3A 193 RDHA-LAN-CDC T-16A 194 RPEC-LAN-FAD T-10A 4 RPGC-LAN-CSM T-3A 193 RDHA-LAN-CDD T-16A 194 RPEC-LAN-FAK T-10A 4 RPGC-LAN-CTE T-3A 193 RDHA-LAN-CDO T-16A 194 RPEC-LAN-FAL T-10A 4 RPGC-LAN-CTM T-3A 193 RDHA-LAN-CDW T-16A 194 RPEC-LAN-FBA T-10A 146 RPGC-LAN-VTE T-3A 183 RDHA-LAN-CDZ T-16A 194 RPEC-LAN-FBC T-10A 146 RPGC-LAN-YCD T-3A 9 RDHA-LAN-IAD T-16A 5 RPEC-LAN-FBP T-10A 146 RPGC-LAN-YCE T-3A 9 RDHA-LAN-IAE T-16A 5 RPEC-LAN-FBX T-10A 146 RPGC-LAN-YCL T-3A 9 RDHA-LAN-IAF T-16A 5 RPEC-LAN-FBY T-10A 146 RPGC-LAN-YCM T-3A 9 RDHA-LAN-IAL T-16A 5 RPEC-LAN-FEB T-10A 6 RPGC-LAN-ZLF T-3A 183 RDHA-LAN-IAM T-16A 5 RPEC-LAN-FEC T-10A 6 RPGC-LAN-ZLW T-3A 183 RDHA-LAN-IEE T-16A 7 RPEC-LAN-FEI T-10A 6 RPGC-LAN-ZLX T-3A 183 RDHA-LAN-IEF T-16A 7 RPEC-LAN-FEJ T-10A 6 RPIC-LAN-CDC T-16A 194 RDHA-LAN-IEL T-16A 7 RPEC-LAN-FRB T-10A 145 RPIC-LAN-CDD T-16A 194 RDHA-LAN-IEM T-16A 7 RPEC-LAN-FRC T-10A 161 RPIC-LAN-CDO T-16A 194 RDHA-LAN-YIF T-16A 10 RPEC-LAN-FRJ T-10A 145 RPIC-LAN-CDW T-16A 194 RDHA-LAN-YIN T-16A 10 RPEC-LAN-FRK T-10A 161 RPIC-LAN-CDZ T-16A 194 RDJA-LAN-LA6 T-18A 5 RPEC-LAN-FSB T-10A 145 RPIC-LAN-IAD T-16A 5 RDJA-LAN-LAD T-18A 5 RPEC-LAN-FSC T-10A 161 RPIC-LAN-IAE T-16A 5 RDJA-LAN-LAE T-18A 5 RPEC-LAN-FSJ T-10A 145 RPIC-LAN-IAF T-16A 5 RDJA-LAN-LAF T-18A 5 RPEC-LAN-FSK T-10A 161 RPIC-LAN-IAL T-16A 5 RDJA-LAN-LAL T-18A 5 RPEC-LAN-FTC T-10A 161 RPIC-LAN-IAM T-16A 5 RDJA-LAN-LAM T-18A 5 RPEC-LAN-FTK T-10A 161 RPIC-LAN-IEE T-16A 7 RDJA-LAN-LEE T-18A 7 RPEC-LAN-YFB T-10A 9 RPIC-LAN-IEF T-16A 7 RDJA-LAN-LEF T-18A 7 RPEC-LAN-YFC T-10A 9 RPIC-LAN-IEL T-16A 7 RDJA-LAN-LEL T-18A 7 RPEC-LAN-YFI T-10A 9 RPIC-LAN-IEM T-16A 7 RDJA-LAN-LEM T-18A 7 RPEC-LAN-YFJ T-10A 9 RPIC-LAN-YIF T-16A 10 RDJA-LAN-VTN T-18A 8 RPEC-LAN-ZHH T-10A 173 RPIC-LAN-YIN T-16A 10 RDJA-LAN-XYZ T-18A 8 RPEC-LAN-ZHJ T-10A 173 RPKC-LAN-LA6 T-18A 5 RDJA-LAN-YL6 T-18A 10 RPEC-LAN-ZHK T-10A 173 RPKC-LAN-LAD T-18A 5 RDJA-LAN-YLR T-18A 10 RPEC-LAN-ZHL T-10A 173 RPKC-LAN-LAE T-18A 5 RPCC-LAN-AAA T-162A 4 RPEC-LAN-ZHP T-10A 173 RPKC-LAN-LAF T-18A 5 RPCC-LAN-AAB T-162A 4 RPEC-LAN-ZHQ T-10A 173 RPKC-LAN-LAL T-18A 5 RPCC-LAN-AAH T-162A 4 RPEC-LAN-ZHR T-10A 173 RPKC-LAN-LAM T-18A 5 RPCC-LAN-AAI T-162A 4 RPEC-LAN-ZHS T-10A 173 RPKC-LAN-LEE T-18A 7 RPCC-LAN-AEA T-162A 6 RPGC-LAN-CAC T-3A 4 RPKC-LAN-LEF T-18A 7 RPCC-LAN-AEB T-162A 6 RPGC-LAN-CAD T-3A 4 RPKC-LAN-LEL T-18A 7 RPCC-LAN-AEH T-162A 6 RPGC-LAN-CAH T-3A 4 RPKC-LAN-LEM T-18A 7 RPCC-LAN-AEI T-162A 6 RPGC-LAN-CAI T-3A 4 RPKC-LAN-VTN T-18A 8 RPCC-LAN-AYA T-162A 9 RPGC-LAN-CEJ T-3A 6 RPKC-LAN-XYZ T-18A 8 RPCC-LAN-AYB T-162A 9 RPGC-LAN-CEL T-3A 6 RPKC-LAN-YL6 T-18A 10 273 US Selected Assemblies Catalogue #999-901-192 Model Code Index ASSEMBLIES Model Code Cavity Page Model Code Cavity Page Model Code Cavity Page RPKC-LAN-YLR T-18A 10 RSHC-LAN-H6L T-17A 25 SCEA-LAN-BCI T-2A 30 RS*C-LAN-EB4 T-11A 148 RSHC-LAN-H6M T-17A 25 SCGA-LAN-HCE T-17A 31 RS*C-LAN-EB5 T-11A 148 RSHC-LAN-H8E T-17A 26 SCGA-LAN-HCF T-17A 31 RSBC-LAN-J6* T-163A 24 RSHC-LAN-H8F T-17A 26 SCGA-LAN-HCL T-17A 31 RSBC-LAN-J6* T-163A 24 RSHC-LAN-HB4 T-17A 195 SCGA-LAN-HCM T-17A 31 RSBC-LAN-J6* T-163A 24 RSHC-LAN-HB6 T-17A 195 SCIA-LAN-KCE T-19A 31 RSBC-LAN-J6* T-163A 24 RSHC-LAN-HB7 T-17A 195 SCIA-LAN-KCF T-19A 31 RSBC-LAN-JCA T-163A 22 RSHC-LAN-HBW T-17A 195 SXCA-LAN-E6B T-11A 24 RSBC-LAN-JCB T-163A 22 RSHC-LAN-HCE T-17A 23 SXCA-LAN-E6C T-11A 24 RSBC-LAN-JCH T-163A 22 RSHC-LAN-HCF T-17A 23 SXCA-LAN-E6I T-11A 24 RSBC-LAN-JCI T-163A 22 RSHC-LAN-HCL T-17A 23 SXCA-LAN-E6J T-11A 24 RSDC-LAN-E6B T-11A 24 RSHC-LAN-HCM T-17A 23 SXCA-LAN-E6K T-11A 24 RSDC-LAN-E6C T-11A 24 RSJC-LAN-K6E T-19A 25 SXCA-LAN-E8B T-11A 26 RSDC-LAN-E6I T-11A 24 RSJC-LAN-K6F T-19A 25 SXCA-LAN-E8C T-11A 26 RSDC-LAN-E6J T-11A 24 RSJC-LAN-KCE T-19A 23 SXCA-LAN-E8I T-11A 26 RSDC-LAN-E6K T-11A 24 RSJC-LAN-KCF T-19A 23 SXCA-LAN-E8J T-11A 26 RSDC-LAN-E8B T-11A 26 RVBA-LAN-JCA T-163A 14 SXCA-LAN-EB4 T-11A 148 RSDC-LAN-E8C T-11A 26 RVBA-LAN-JCB T-163A 14 SXCA-LAN-EB5 T-11A 148 RSDC-LAN-E8I T-11A 26 RVBA-LAN-JCH T-163A 14 SXCA-LAN-EBW T-11A 148 RSDC-LAN-E8J T-11A 26 RVBA-LAN-JCI T-163A 14 SXCA-LAN-ECB T-11A 22 RSDC-LAN-ECB T-11A 22 RVCA-LAN-ECB T-11A 14 SXCA-LAN-ECC T-11A 22 RSDC-LAN-ECC T-11A 22 RVCA-LAN-ECC T-11A 14 SXCA-LAN-ECH T-11A 22 RSDC-LAN-ECH T-11A 22 RVCA-LAN-ECH T-11A 14 SXCA-LAN-ECI T-11A 22 RSDC-LAN-ECI T-11A 22 RVCA-LAN-ECI T-11A 14 SXCA-LAN-ECJ T-11A 22 RSDC-LAN-ECJ T-11A 22 RVCA-LAN-ECJ T-11A 14 SXEA-LAN-B6B T-2A 24 RSDG-LAN-EBW/M T-11A 148 RVEA-LAN-BBC T-2A 163 SXEA-LAN-B6C T-2A 24 RSFC-LAN-B6B T-2A 24 RVEA-LAN-BCC T-2A 14 SXEA-LAN-B6D T-2A 24 RSFC-LAN-B6C T-2A 24 RVEA-LAN-BCD T-2A 14 SXEA-LAN-B6J T-2A 24 RSFC-LAN-B6D T-2A 24 RVEA-LAN-BCI T-2A 14 SXEA-LAN-B6K T-2A 24 RSFC-LAN-B6J T-2A 24 RVEA-LAN-BCJ T-2A 14 SXEA-LAN-B8C T-2A 26 RSFC-LAN-B6K T-2A 24 RVGA-LAN-HCD T-17A 15 SXEA-LAN-B8D T-2A 26 RSFC-LAN-B8C T-2A 26 RVGA-LAN-HCE T-17A 15 SXEA-LAN-B8J T-2A 26 RSFC-LAN-B8D T-2A 26 RVGA-LAN-HCF T-17A 15 SXEA-LAN-BB4 T-2A 164 RSFC-LAN-B8J T-2A 26 RVGA-LAN-HCL T-17A 15 SXEA-LAN-BB5 T-2A 164 RSFC-LAN-BB4 T-2A 164 RVGA-LAN-HCM T-17A 15 SXEA-LAN-BBW T-2A 164 RSFC-LAN-BB5 T-2A 164 RVIA-LAN-KC6 T-19A 15 SXEA-LAN-BCD T-2A 22 RSFC-LAN-BBW T-2A 164 RVIA-LAN-KCE T-19A 15 SXEA-LAN-BCI T-2A 22 RSFC-LAN-BCD T-2A 22 RVIA-LAN-KCF T-19A 15 SXEA-LAN-BCJ T-2A 22 RSFC-LAN-BCI T-2A 22 RVIA-LAN-KCN T-19A 15 SXEA-LAN-BCL T-2A 22 RSFC-LAN-BCJ T-2A 22 RVIA-LAN-XZZ T-19A 16 SXEA-LAN-BJ4 T-2A 175 RSFC-LAN-BCL T-2A 22 RVIA-LAN-Z8Z T-19A 16 SXEA-LAN-BJ5 T-2A 175 RSFC-LAN-BJ4 T-2A 175 RVCA-LAN-EBC T-11A 147 SXEA-LAN-BJW T-2A 175 RSFC-LAN-BJ5 T-2A 175 SCCA-LAN-ECB T-11A 30 X2CD-LAN-CA 156 RSFC-LAN-BJW T-2A 175 SCCA-LAN-ECC T-11A 30 X2DD-LAN-CA 172 RSHC-LAN-BK4 T-17A 185 SCCA-LAN-ECH T-11A 30 X2DD-LAN-HA 172 RSHC-LAN-BK5 T-17A 185 SCCA-LAN-ECI T-11A 30 X3DD-LAN-CA 172 RSHC-LAN-BK6 T-17A 185 SCCA-LAN-ECJ T-11A 30 X3DD-LAN-HA 172 RSHC-LAN-BK7 T-17A 185 SCEA-LAN-BCB T-2A 30 X4CD-LAN-CA 157 RSHC-LAN-BKW T-17A 185 SCEA-LAN-BCC T-2A 30 X4DD-LAN-CA 172 RSHC-LAN-H6E T-17A 25 SCEA-LAN-BCD T-2A 30 X4DD-LAN-HA 172 RSHC-LAN-H6F T-17A 25 SCEA-LAN-BCH T-2A 30 X6DD-LAN-CA 172 US Selected Assemblies Catalogue #999-901-192 274 Model Code Index ASSEMBLIES Page Model Code X6DD-LAN-HA Model Code Cavity Page 172 YCJD-L*N-GR Model Code Cavity 206 YDJC-LHN-AN 227 XRCA-LAN-*A 17 YCJD-L*N-HR 206 YDJC-LHN-AS 227 XRCA-LAN-*B 17 YCJE-L*N-AR 210 YFCG-XHN-AA 158 XRCA-LAN-*C 17 YCJE-L*N-GR 210 YFCJ-XHN-AA 158 XRCA-LAN-*I 17 YCJE-L*N-HR 210 YFFE-XHN-AB 192 XRCA-LAN-*J 17 YCJG-L*N-AR 212 YFFF-XHN-AB 192 XRCD-LAN-CA 147 YCJG-L*N-GR 212 YFIA-XHN-CA 202 XRCD-LAN-HA 147 YCJG-L*N-HR 212 YFIB-XHN-CA 202 XRDB-LCN-AL 218 YCJH-L*N-AR 208 YNAA-LDN-AA 158 XRDC-LNN-AK 214 YCJH-L*N-GR 208 YRDR-LAN-LA 138 XRDC-LNN-AL 214 YCJH-L*N-HR 208 YRDR-LAN-LB 138 XREA-LAN-*A 17 YDCA-LHN-AA 158 YRDR-LAN-LC 138 XREA-LAN-*B 17 YDCC-LHN-AC 224 YRDR-LAN-LI 138 XREA-LAN-*C 17 YDCC-LHN-AK 224 YRDR-LAN-LJ 138 XREA-LAN-*D 17 YDCD-LHN-AC 224 YRDR-LAN-LK 138 XREA-LAN-*J 17 YDCD-LHN-AK 224 YREM-LAN-LC 138 XREA-LAN-*L 17 YDEC-LHN-AD 225 YREM-LAN-LD 138 XRED-LAN-CA 163 YDEC-LHN-AL 225 YREM-LAN-LK 138 XRED-LAN-HA 163 YDED-LHN-AD 225 YREM-LAN-LL 138 XRFB-LCN-A4 219 YDED-LHN-AL 225 YRFF-LAN-LD 138 XRFB-LCN-AP 219 YDFE-LHN-AB 192 YRFF-LAN-LE 138 XRFC-LNN-A4 214 YDFG-LHN-AB 192 YRFF-LAN-LF 138 XRGA-LAN-*P 18 YDGC-LHN-AD 226 YRFF-LAN-LL 138 XRHB-LCN-A5 220 YDGC-LHN-AE 226 YRFF-LAN-LM 138 XRHB-LCN-AQ 220 YDGC-LHN-AF 226 ZJR 159 XRHC-LNN-AM 215 YDGC-LHN-AL 226 ZPT 159 XRIA-LAN-*S 18 YDGC-LHN-AM 226 ZUO 159 XRJB-LCN-AR 221 YDGD-LHN-AD 226 ZVT 159 XRJB-LCN-AS 221 YDGD-LHN-AE 226 ZWV 159 XRJC-LNN-A6 216 YDGD-LHN-AF 226 ZWW 159 XRJC-LNN-AM 215 YDGD-LHN-AL 226 XRJC-LNN-AR 216 YDGD-LHN-AM 226 XRJC-LNN-AS 217 YDGE-LHN-CA 202 YCJD-L*N-AR 206 YDGF-LHN-CA 202 275 Cavity Page US Selected Assemblies Catalogue #999-901-192 Warranty WARRANTY INFORMATION, PERFORMANCE ASSURANCE, AND APPLICATION LIMITATIONS Caution Sun Hydraulics Corporation manufactures a variety of cartridge valves that will fit into the same Sun cavity. Each cartridge is marked with a seven-digit part identification code and a four-digit date code, stamped on the hex surfaces. Designers and users of Sun components are advised that physical interchangeability of cartridges does not necessarily mean functional interchangeability. When replacing any Sun cartridges, users should first check with the manufacturer's service literature, their local Sun distributor, or the Sun factory before making any part substitutions. NOTE: To avoid serious injury, the manufacturer's service manual must be consulted before working on any hydraulic system. Limited Warranty Sun Hydraulics Corporation warrants its products free from defects in material, workmanship, and design for a period of three years after installation, provided the installation date is less than one year after manufacture. “O-rings” and seals are specifically exempted from this warranty. In no instance is there any warranty of fitness for a particular use and Sun Hydraulics Corporation cannot and does not accept responsibility of any type for any of its products that have been subjected to improper installation, improper application, negligence, tampering, or abuse, or which have been repaired or altered outside of the Sun Hydraulics factory. Sun Hydraulics Corporation’s liability under this warranty shall extend only to replacement or correction, f.o.b. our factory, of any defective part or product determined by inspection as not conforming to this warranty. We make no other warranties, expressed or implied, and are not responsible for any consequential damages resulting from use by any buyer or user, our liability being limited to the value of product sold or obligation to replace a defective part. Performance Assurance All Sun cartridges are individually tested at the factory and preset to specific pressure or flow settings where indicated in this catalog. However, as the actual performance of buyers' equipment cannot be reproduced in Sun's testing laboratory, assurance of suitability of all Sun products in the buyer's application is the responsibility of the buyer. This is typically accomplished by the manufacture of a prototype followed by a test or qualification program on the part of the buyer. Application Limitations Sun's product designs and manufacturing facilities have been specifically developed to provide products for commercial, industrial and mobile hydraulic applications and Sun's products are only warranted for this type of use. Sun's distributors are not authorized to approve the use of Sun products in any of the following applications: • Any product that comes under the Federal Highway Safety Act, namely steering or braking systems for passenger-carrying vehicles or on-highway trucks. US Selected Assemblies Catalogue #999-901-192 276 • • • • Aircraft or space vehicles. Ordnance equipment. Life support equipment. Any end product that, when sold, comes under the U.S. Nuclear Regulatory Commission rules and regulations. Specific written approval for any application of Sun products in any of the above named applications should be obtained from Sun Hydraulics Corporation. Consultation with Sun distributors or factory engineers is advised in unusual situations where applicability is questionable.