Contents - Sun Hydraulics

Transcription

Contents - Sun Hydraulics
Contents
The Sun Product . . . . . . . . . . . . . . . . iii
Technical Product Information . . v
SAE Counterbore Diameters
Table. . . . . . . . . . . . . . . . . . . . . . . . . . vii
SAE Flange Pattern
Specifications Table . . . . . . . . . . . . . . viii
Relief Assemblies
Relief Valves
Two Port Relief . . . . . . . . . . . . . . . . 1
Pilot Operated . . . . . . . . . . . . . . . 2
Direct Acting . . . . . . . . . . . . . . . . 2
Line Mounted Assemblies. . . . . . . . . . . 4
Three Port Relief . . . . . . . . . . . . . . . 11
Pilot Operated with Vent . . . . . . . 12
Line Mounted Assemblies. . . . . . . . . . . 14
Sequence Assemblies
Sequence Valves
Pilot Operated . . . . . . . . . . . . . . . . .
Direct Acting . . . . . . . . . . . . . . . . . .
Line Mounted Assemblies. . . . . . . . . . .
Direct Acting with Reverse
Free Flow Check Valves. . . . . . . . .
Line Mounted Assemblies . . . . . . . .
20
20
22
28
30
Needle Assemblies
Needle Valves
Fully Adjustable . . . . . . . . . . . . . . . .110
Fully Adjustable with
Reverse Free Flow Check . . . . . . . .110
Line Mounted Assemblies . . . . . . . . . . .113
Pressure Compensated
Flow Control Assemblies
Flow Control Valves
Fixed Orifice . . . . . . . . . . . . . . . . . . .117
Pressure Compensated. . . . . . . . . .118
Pressure Compensated with
Free Flow Check . . . . . . . . . . . . .118
Line Mounted Assemblies . . . . . . . . . . .120
Fully Adjustable Pressure
Compensated with Free
Flow Check . . . . . . . . . . . . . . . . . . .126
Line Mounted Assemblies . . . . . . . . . . .128
Priority Flow Control
Assemblies
Priority Flow Control Valves
Bypass/Restrictive, Fixed
Orifice . . . . . . . . . . . . . . . . . . . . . . .134
Line Mounted Assemblies . . . . . . . . . . .136
Pressure Reducing Assemblies
Sandwich Assemblies
Reducing Valves
Pilot Operated . . . . . . . . . . . . . . . . . 34
Line Mounted Assemblies. . . . . . . . . . . 36
Sandwich Body Technical
Product Information . . . . . . . . . . . . . .140
Studkits for ISO 03 and ISO 05
Sandwich Bodies . . . . . . . . . . . . .142
ISO 03 Studkits . . . . . . . . . . . . . . .142
ISO 05 Studkits . . . . . . . . . . . . . . .142
Studrod Length Determination
Chart. . . . . . . . . . . . . . . . . . . . . . .143
ISO 03 / CETOP 3 Assemblies
Relief . . . . . . . . . . . . . . . . . . . . . . .145
Sequence . . . . . . . . . . . . . . . . . . . .148
Reducing . . . . . . . . . . . . . . . . . . . .149
Reducing/Relieving . . . . . . . . . . . .150
Counterbalance . . . . . . . . . . . . . . .151
Pilot-to-Open Check . . . . . . . . . . .152
Check. . . . . . . . . . . . . . . . . . . . . . .153
Priority Flow Control . . . . . . . . . .154
Flow Control . . . . . . . . . . . . . . . . .155
Circuit Saver . . . . . . . . . . . . . . . . .158
ISO 05 / CETOP 5 Assemblies
Relief . . . . . . . . . . . . . . . . . . . . . . .163
Sequence . . . . . . . . . . . . . . . . . . . .164
Reducing . . . . . . . . . . . . . . . . . . . .165
Reducing/Relieving . . . . . . . . . . . .166
Counterbalance . . . . . . . . . . . . . . .167
Pilot-to-Open Check . . . . . . . . . . .168
Check. . . . . . . . . . . . . . . . . . . . . . .169
Flow Control . . . . . . . . . . . . . . . . .170
ISO 05 / CETOP 5
with X and Y Assemblies
Relief . . . . . . . . . . . . . . . . . . . . . . .173
Reducing / Relieving Assemblies
Reducing/Relieving Valves
Pilot Operated . . . . . . . . . . . . . . . . . 42
Direct Acting . . . . . . . . . . . . . . . . . . 42
Line Mounted Assemblies. . . . . . . . . . . 44
Counterbalance Assemblies
Counterbalance Valves
Three Port Standard . . . . . . . . . . . . .
Line Mounted Assemblies. . . . . . . . . . .
Four Port Vented . . . . . . . . . . . . . . .
Line Mounted Assemblies. . . . . . . . . . .
50
52
70
72
Pilot-to-Open Check Assemblies
Pilot-to-Open Check Valves
Three Port . . . . . . . . . . . . . . . . . . . .
Pilot Operated . . . . . . . . . . . . . . .
Line Mounted Assemblies. . . . . . . . . . .
Four Port . . . . . . . . . . . . . . . . . . . . .
Vented, Four Port Cavity . . . . . . .
Line Mounted Assemblies. . . . . . . . . . .
77
78
80
93
94
96
Check Assemblies
Check Valves
1 to 2 Free Flow. . . . . . . . . . . . . . . . 102
2 to 1 Free Flow. . . . . . . . . . . . . . . . 102
Line Mounted Assemblies. . . . . . . . . . . 104
US Selected Assemblies Catalogue #999-901-192
i
Sequence . . . . . . . . . . . . . . . . . . . . 175
Reducing . . . . . . . . . . . . . . . . . . . . 176
Reducing/Relieving . . . . . . . . . . . 177
Counterbalance . . . . . . . . . . . . . . . 178
Pilot-to-Open Check . . . . . . . . . . . 179
Check . . . . . . . . . . . . . . . . . . . . . . 180
Flow Control . . . . . . . . . . . . . . . . . 181
ISO 07 / CETOP 7 Assemblies
Relief. . . . . . . . . . . . . . . . . . . . . . . 183
Sequence . . . . . . . . . . . . . . . . . . . . 185
Reducing . . . . . . . . . . . . . . . . . . . . 186
Reducing/Relieving . . . . . . . . . . . 187
Counterbalance . . . . . . . . . . . . . . . 188
Pilot-to-Open Check . . . . . . . . . . . 189
Check . . . . . . . . . . . . . . . . . . . . . . 190
Flow Control . . . . . . . . . . . . . . . . . 191
Circuit Saver . . . . . . . . . . . . . . . . . 192
ISO 08 / CETOP 8 Assemblies
Relief. . . . . . . . . . . . . . . . . . . . . . . 193
Sequence . . . . . . . . . . . . . . . . . . . . 195
Reducing . . . . . . . . . . . . . . . . . . . . 196
Reducing/Relieving . . . . . . . . . . . 197
Counterbalance . . . . . . . . . . . . . . . 198
Pilot-to-Open Check . . . . . . . . . . . 199
Check . . . . . . . . . . . . . . . . . . . . . . 200
Flow Control . . . . . . . . . . . . . . . . . 201
Circuit Saver . . . . . . . . . . . . . . . . . 202
Standard Assemblies
Cushion Lock Valves
Technical Information. . . . . . . . . . 204
Assemblies . . . . . . . . . . . . . . . . . . 205
Hydrostatic Transmission
and Hot Oil Shuttle
Technical Information. . . . . . . . . . 213
Assemblies . . . . . . . . . . . . . . . . . . 214
Line Mounted Regenerative
Circuits
Technical Information. . . . . . . . . . 223
Assemblies . . . . . . . . . . . . . . . . . . 224
Direct Motor Mounted
Technical Information. . . . . . . . . . 229
Char-Lynn S Series Assemblies . . 230
Danfoss (OMP/OMR Series
and OMT Series) Assemblies . . . 237
General Information
Cartridge Control Options . . . . . . . . 244
Cartridge Control Kits . . . . . . . . . . . 245
Cavity Plugs . . . . . . . . . . . . . . . . . . . 246
Solenoid Electrical
Connector Options . . . . . . . . . . . . . 248
Orifice Pressure Drop Data . . . . . . . 249
Visit www.sunhydraulics.com for
current Tooling infomation.
Model Code Index . . . . . . . . . . . . . . 264
Warranty . . . . . . . . . . . . . . . . . . . . . 276
SUN RECOMMENDED QUANTITY DISCOUNTS FOR STANDARD VALVES
One line item
One order
One shipment
F.O.B. Sarasota, FL. USA
Prices shown for SUN Cavity form tools are net and not subject to discounts.
Prices for Custom Products and Modifications of Standard Valves are by quotation only.
Quantity: 1-2
Discount: List
3-9
7%
10-29
15%
30-99
25%
100-299
35%
300-999
On Request
Consult your SUN distributor for terms and conditions covering blanket orders or orders for scheduled repetitive shipments.
Sun Hydraulics Corporation reserves the right to change existing prices and discounts at any time without notice to its customers.
Selling prices are governed by the price list in effect at the time of acceptance of a purchase order.
MODEL CODES PRINTED IN RED
IN THIS CATALOGUE
ARE PREFERRED PRODUCTS
AND ARE READILY AVAILABLE.
Specifications, descriptions and illustrative material contained herein were as accurate as known
at the time this publication was approved for printing.
Sun Hydraulics Corporation reserves the right to discontinue models at any time,
or change prices, specifications or designs without notice or incurring obligation.
This catalogue is published by
Sun Hydraulics Corporation
1500 West University Parkway, Sarasota, FL 34243 USA.
All rights reserved.
This book, or any part thereof, may not be reproduced or transmitted
in any form or by any means, electronic or mechanical, including
photocopying, recording, or information storage and retrieval systems, for any purpose
without the express written permission of Sun Hydraulics Corporation.
© 2002 Sun Hydraulics Corporation
Sarasota, FL 34243 USA
Printed in the United States of America
Catalogue #999-901-192
ii
US Selected Assemblies Catalogue #999-901-192
Overview
THE SUN PRODUCT
Five Cartridge Sizes
Flows to 200 GPM
(400 GPM for some applications).
Sun screw-in cartridge type hydraulic
valves for industrial and mobile
applications are basic building blocks.
Each cartridge contains the active
elements needed for hydraulic control
functions in a convenient and reliable
lightweight envelope. Cartridges are
available in standard pressure ranges up to
5000 psi (6000 psi in some models). Every
cartridge receives a complete functional
test prior to shipment.
The use of cartridge valves in hydraulic
systems will:
Sun screw-in cartridges, available in five sizes, are suitable for both mobile and
industrial applications.
•
•
•
•
•
•
•
•
Improve system reliability
Simplify circuits
Reduce leakage points
Reduce piping costs
Save space and weight
Simplify service
Reduce assembly time
Reduce spare parts inventory
A significant advantage in the design of
Sun cartridges is that the working parts
“float” in the body, so they are not
susceptible to binding caused by
overtorquing, during installation in the
cavity. (See illustration on inside front
cover.)
Sun utilizes relatively few cartridge
cavities throughout its entire range of
cartridge products. Many valve functions
and ranges can be interchanged in the
same cavity. The result is greatly increased
flexibility, and the capability to modify
circuits without disturbing any piping,
breaking unions or unplumbing any
valves.
A wide range of standard bodies are available to simplify the installation of Sun
cartridges in new and existing circuits.
US Selected Assemblies Catalogue #999-901-192
iii
Line Mounted Bodies
Sun manufactures a wide range of
standard bodies to simplify the installation
of cartridges in new and existing circuits.
SAE O-ring straight thread, NPTF, BSPP,
SAE Code 61 and 62 split flange, and
other ports are available. Two hydraulic
functions are frequently combined in a
single body to simplify piping. All bodies
are available in aluminum or ductile iron.
Overview
THE SUN PRODUCT
Sandwich Bodies and Subplates
Sun's sandwich valves and subplates are
complete circuit elements which mount
directly under the solenoid valve. Most
hydraulic functions are available in
sandwich bodies and subplates. They are
available in aluminum or ductile iron and
provide a simple method of incorporating
circuit controlling components right at the
solenoid valve. Sandwich valves and
subplates can be easily assembled with
studrods and studnuts. The result is a
clean, neat assembly with a minimum of
external piping that is easily accessible for
modification.
Pre-packaged Valve Assemblies
Sandwich bodies and subplates provide a simple method of incorporating
controlling components right at the solenoid valve.
A wide variety of pre-packaged valve
assemblies are available to perform many
of the more common hydraulic circuit
functions. These assemblies incorporate
two or more different cartridges in a
manifold body with a choice of porting
options and are available in aluminum or
ductile iron.
Direct Motor Mount Bodies
Mounting configurations offered by Sun
match the mounting patterns of selected
Char-Lynn, Danfoss, Staffa, HPI, Parker
Ross, and White motors. These valve
assemblies provide relief, counterbalance,
and flow control functions for mounting
directly to a motor, and are available in
aluminum or ductile iron.
Pre-packaged valve assemblies for common
hydraulic circuit functions.
Direct Motor Mount
bodies for commercial
hydraulic motors.
Integration into Hydraulic Components
Directly integrating cartridge valves into
the housing of other components is a very
cost effective and compact method of
packaging multiple hydraulic functions.
Cavity form tools for machining the
cartridge cavity are readily available from
Sun.
Custom Valve Packages
It is often desirable and economical to
incorporate several cartridges into a
special, application specific manifold
body to simplify a circuit, reduce piping
costs, fit into a confined space, or solve a
mounting problem.
Direct integration is cost-effective
and compact.
Custom valve packages for specific
applications.
Sun Hydraulics and its network of
Authorized Distributors (see inside back
cover) will work with you to develop
customized solutions to your particular
application problems.
iv
US Selected Assemblies Catalogue #999-901-192
Cartridges
TECHNICAL PRODUCT INFORMATION
Cartridge Installation
Sun cartridge valves are manufactured
from carbon steel with all external parts
zinc plated to protect against corrosion.
Critical internal working parts (sliding
spool valves often have a clearance
between fixed and working parts of 5
microns or less) are heat treated and
precision ground or lapped, to ensure
repeatable, reliable performance.
Sun cartridge valves are available in five
different sizes with capacities doubling
from one size to the next. These cartridges
can only be used in a Sun cavity that
matches the external configuration of the
cartridge. When installing cartridges in
their cavities, they should be torqued to the
recommended value.
All cartridges have Buna-N seals as
standard, with Viton optional. Buna-N
seals have an operating range of -50° F to
200° F. Viton seals have an operating
range of 0° F to 250° F.
Filtration
As with any precision hydraulic
component, clean oil contributes to long
life and reliable performance. The most
common cause of failure of a cartridge is
dirt in the hydraulic fluid, which can then
lodge in the working parts of the cartridge
and interfere with operation.
Most Sun pilot operated valves feature a
150 micron stainless steel screen or
equivalent, to protect the control orifice
from contamination. This filter is
produced from electrochemically etched
stainless steel sheets to provide a
consistent screening material.
It is recommended that hydraulic fluid
used in systems with Sun valves have an
ISO 4406 contamination level of 18/15 or
better at all times. Consult your
Authorized Distributor for filtration
requirements to meet this cleanliness
level.
Pressure and Flow Rating –
Performance Data
All performance data in this catalog is
derived using Chevron ISO Grade 32
petroleum based hydraulic fluid having a
specific gravity of 0.87 at 60° F. All tests
are conducted at 110° F.
Leakage is often specified in units of drops
per minute in this catalog. For reference,
250 drops equal 1 cubic inch.
All cartridge valves go through functional
testing before shipment. Tests are
performed using petroleum based
hydraulic fluid (ISO Grade 32) at a
temperature of 110° F (SUS = 130). Test
stand cleanliness is maintained at ISO
17/14 or better.
All performance data provided is
developed in our laboratory.
Standard and special set pressure controls
are set at the following flow rates:
■
Materials
■
All manifolds and bodies are available in
aluminum or ductile iron. Aluminum
bodies are made of wrought 6061-T6
grade aluminum and have a maximum
pressure rating of 3000 psi, a proof rating
of 6000 psi, and a burst rating of
12,000 psi.
Ductile iron bodies are made of
continuous cast, grade 65-45-12 iron.
Ductile iron bodies have a maximum
pressure rating of 5000 psi, with a proof
rating of 10,000 psi, and burst rating of
20,000 psi.
Porting Options
Sun offers many porting options in its
mounting configurations, including, but
not limited to: SAE Code 61 and 62 split
flanges, NPTF dry seal threads, SAE
O-ring threaded ports, and BSPP
(Whitworth) threads.
■
Cartridge valves are basic service items
and they are easily removed in the field.
See Caution below and the Sun Service
Bulletin for details.
A non-functioning cartridge should be
returned to Sun through your local
Authorized Distributor for evaluation. A
full report of our findings will be issued
upon request.
Caution! – Prior to removing any
cartridge:
1.
Refer to the equipment
manufacturer's documentation for
recommendations relating to
precautions for securing any
moving elements associated with
the hydraulic system or equipment.
(If documentation does not exist,
ensure that all loads are adequately
supported.)
2.
Ensure that the hydraulic system is
de-pressurized.
Sandwich Interface Patterns
Most sandwich and subplate bodies are
available in the following interface
configurations:
ISO 02
ISO 03
ISO 05*
ISO 07
ISO 08
NFPA D02
NFPA D03
NFPA D05
NFPA D07
NFPA D08
* Available with X and Y ports
v
NG 4
NG 6
NG 10
NG 16
NG 25
Load Control Valves - 2 in.3/min.
Pressure Reducing Valves - 0 flow
(blocked control port).
All Other Valves - 4 GPM.
Sun Service Instructions
Please note that some bodies with SAE
O-ring threaded ports utilize a modified
spot face diameter for conservation of
materials.
Unless otherwise specified, Sun cartridges
are rated to 5000 psi (6000 psi
intermittent). All Sun cartridges are
designed with a 4:1 safety factor. This
means the minimum burst pressure is at
least four times the maximum rated
operating pressure.
US Selected Assemblies Catalogue #999-901-192
Testing
Cartridges
TECHNICAL PRODUCT INFORMATION
Solenoid Cartridge Valves
Sun Hydraulics offers a variety of pilot
solenoid cartridges and direct acting full
flow solenoid cartridges to suit most
application requirements.
■
■
Full Flow Valves
Rated for Reliability
■
■
■
Direct acting full flow solenoid
cartridges will operate reliably at their
maximum pressure (3600 psi) and flow
ratings (10 GPM).
All pressure and flow ratings are
conservative to ensure that the final
circuit will function as the designer
intended.
These solenoid cartridge valves will
operate at rated conditions with a life
expectancy in excess of 20 million
cycles.
Connector and Voltage Options
■
■
■
■
■
Multiple Versions
Two port, 2 position / 2-way solenoids are
available in either spool or poppet
versions, each offered in both normally
open and normally closed configurations.
■
■
■
■
Spool version exhibit maximum
leakage rates of 5 in3/min. at 3600 psi
and are recommended for high flow
requirements where leakage is not
critical.
Poppet version exhibit maximum
leakage rates of 10 drops/min. at 3600
psi.
Three port, 2 position / 3-way spool
type cartridges exhibit all of the
features of the two position / 2-way
spool cartridges.
Solenoid cartridges feature a standard
push-type manual override.
Designed for Application Flexibility
These direct acting valves require no
minimum pressure for their operation.
■
■
An efficient coil and tube design
generates maximum force output with
only 22 watts of power, so the valves
exhibit consistent and reliable
operation.
The high force output of the solenoid
ensures that there is enough power to
overcome flow forces that may
otherwise prevent the valve from
shifting.
Within each cartridge version, the
normally open and normally closed
configurations have virtually identical
performance, allowing them to be used
interchangeably.
Together these features afford the
circuit designer greatly increased
flexibility.
■
All solenoids are DC type devices.
An internal bridge rectifier is used in
the coil for AC applications.
Coils will operate reliably from 80% to
120% of the rated voltage with a
maximum ambient temperature of
122ºF.
DC coils are offered in 12 and 24-volt
versions with twin lead, DIN or AMP®
Junior Timer connectors.
AC coils are available in both 115 or
230-volt options and feature DIN
connectors.
All coils employ internal transient
voltage suppression protection to
protect externally connected electrical
switching.
High Pressure
Solenoid Pilot Controls
■
■
These small spool-type cartridges
handle flows up to approximately
.25 GPM and will accommodate
pressure up to 5000 psi at all ports.
All pilot solenoid cartridges are rated
for a fatigue life of greater than 20
million cycles at their maximum
working pressure and flow ratings.
Low Power Consumption
■
Integrated Pilot Control
While all of the pilot control solenoid
cartridges can be used individually in
manifolds to control other devices, the
2-way cartridges offer the added benefit of
being able to be directly installed into
other Sun cartridges to provide electrically
operated high flow and high pressure
control.
■
■
■
■
■
■
■
■
Voltage and temperature tolerances of
the pilot solenoids are identical to
those of the full flow valves.
All coils employ internal transient
voltage suppression protection to
protect externally connected electrical
switching.
Both AC and DC coils are offered with
AC coils employing an internal bridge
rectifier.
DC coils are offered in various voltage
options from 6 to 48-volts.
Connector options include DIN, SAE
twin spade and twin leads.
vi
The T-8A cavity is offered as a control
option on many of Sun’s ventable and
pilot operated cartridges to offer high
performance, 5000 psi electrically
controlled products at a competitive
price.
Directly integrating the electrical
control in the main stage function
results in a product that offers
improved control characteristics;
separate pilot lines are eliminated and
only a single cavity needs to be
machined to accommodate both the
control and primary function.
Sun also offers a range of cartridges
that incorporate solenoid pilot controls
to provide directional control for flow
ranges from 15 to 120 GPM.
2-way or 3-way
Pilot control solenoid cartridges are
available in either a two port, 2 position /
2-way (DAAA), or a three port, 2 position
/ 3-way (DBAA), each of which exhibits
internal leakage rates of 10 drop/min.
maximum at 5000 psi.
■
The highly efficient tube design of the
pilot solenoids requires only 12 watts to
shift the valve.
AC coils are offered in 115- and
230-volt options and feature DIN
connectors.
■
■
■
The 2-way versions fit into Sun’s
existing T-8A cavity.
The 3-way versions fit the T-9A cavity.
Both are offered in normally open and
normally closed configurations with a
variety of voltage and connector
options.
The pilot control solenoid valves
include a push-type manual override as
a standard feature.
US Selected Assemblies Catalogue #999-901-192
Line Mount Bodies
LOCATE LINE MOUNT BODIES WITH ALL NECESSARY SPECIFICATIONS
Sun offers many single and multiple cavity standard line mount manifolds, and many
sandwich, motor mount bodies and subplates that are available in a choice of aluminum
(3000 psi/210 bar) or ductile iron (5000 psi/350 bar). Ports include NPTF, SAE, BSPP
and Code 61 and Code 62 flanges.
Go to www.sunhydraulics.com. Example: Click Product: Manifolds: Line Mount: Flow
Controls: Inline: and a pop-up menu shows all the available SAE Ported Bodies within
your selection (see below). When you click the body in the appropriate Cavity column,
the body page will show all measurements, Technical Data and full orientation
views of all body faces. See Technical Information section of web site for additional
information.
US Selected Assemblies Catalogue #999-901-192
vii
NOTES
viii
US Selected Assemblies Catalogue #999-901-192
Two Port Relief Assemblies
Cartridge Type
2
Page
Pilot Operated
2
Direct Acting
2
1
2
1
Line Mounted Assemblies
(Body Type)
2
90 Degree
4
90 Degree with Gauge Port
90 Degree 1.50" SAE C62 Flange Port
5
5
Through Port
6
2.00" SAE C61/62 Flange Port, 2 Cavities
8
1
2
G
1
2
1
1
G
2
1
1
1
Cross-Port, 2 Cavities
2
9-10
2
G
1
1
2
Cross-Port, 2 Cavities with 2 Gauge Ports
Cross-Port, 1.50" SAE C61/C62 Flange Port, 2 Cavities
2
G
US Selected Assemblies Catalogue #999-901-192
1
10
10
TWO PORT RELIEF
Relief Valves
PILOT OPERATED
2
1
Capacity
Typical
Cartridge
Model Code
Cartridge Dimensions
c
b
L
C
12 GPM
RPCC – LAN
T - 162A
1.22
3/4”
2.11
2.17
2.31
Installation
Torque
(lb. ft.)
25/30
25 GPM
RPEC – LAN
T - 10A
1.56
7/8”
2.00
2.06
2.25
30/35
50 GPM
RPGC – LAN
T - 3A
1.88
1 1/8”
2.12
2.18
2.38
45/50
Cavity
a
K
100 GPM
RPIC – LAN
T - 16A
2.44
1 1/4”
2.44
2.47
2.69
150/160
200 GPM
RPKC – LAN
T - 18A
3.13
1 5/8”
2.81
2.94
3.06
350/375
OPTION ORDERING INFORMATION
RP ✱ C – ✱ ✱ ✱
Full Adjustment 5 Turns
+
-
Nominal
Capacity
Base
Price
C 12 GPM*
c
b
Locating
Shoulder
Control**
Adjustment Range
L Standard Screw
N Buna-N
V Viton
E 25 GPM
C Tamper Resistant
W 150 - 4500 psi
G 50 GPM
K Handknob
B 50 - 1500 psi
I
Seal
A 100 - 3000 psi
C 150 - 6000 psi
100 GPM
K 200 GPM
N 60 - 800 psi
Q 60 - 400 psi
a
2
Outlet
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
** See page 244 for information
on Control Options
Inlet 1
DIRECT ACTING
Typical
Cartridge
Model Code
12 GPM
RDBA – LAN
T - 162A
1.22
3/4”
2.11
2.17
Installation
Torque
(lb. ft.)
25/30
25 GPM
RDDA – LAN
T - 10A
1.56
7/8”
2.38
2.44
30/35
Capacity
2
1
Cartridge Dimensions
c
b
L
Cavity
a
C
50 GPM
RDFA – LAN
T - 3A
1.88
1 1/8”
2.50
2.56
45/50
100 GPM
RDHA – LAN
T - 16A
2.44
1 1/4”
3.25
3.31
150/160
200 GPM
RDJA – LAN
T - 18A
3.13
1 5/8”
3.94
4.07
350/375
OPTION ORDERING INFORMATION
RD ✱ A – ✱ ✱ ✱
Full Adjustment 5 Turns
+
-
Nominal
Capacity
c
b
Base
Price
Control**
Adjustment Range
Seal
B 12 GPM
L Standard Screw
A 500 - 3000 psi
N Buna-N
D 25 GPM
C Tamper Resistant
W 1000 - 4500 psi
V Viton
F 50 GPM
B 300 - 1500 psi
H 100 GPM
C 1000 - 6000 psi
J 200 GPM
D 25 - 800 psi
Locating
Shoulder
E 100 - 400 psi
S 50 - 200 psi
a
2
Outlet
Inlet 1
U.S. Patent #4,742,846
European Patent Pending
** See page 244 for information
on Control Options
2
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
D Option is standard set at 400 psi.
E Option is standard set at 200 psi.
S Option is standard set at 100 psi.
Customer may specify pressure setting.
US Selected Assemblies Catalogue #999-901-192
TWO PORT RELIEF
TECHNICAL TIPS / PERFORMANCE CURVES
Relief Valves, Pilot Operated
Performance Curves
Typical Pressure Rise
RPEC-L*N
5000
5000
4000
4000
P = psi
P = psi
RPCC-L*N
3000
2000
3000
2000
1000
1000
0
5
10
20
15
25
0
Flow = GPM
RPGC-L*N
10
20
30
80
120
40
Flow = GPM
50
RPIC-L*N
5000
5000
4000
4000
P = psi
P = psi
Applications
These relief cartridges are normally closed,
pressure control elements that are fully adjustable over
a wide range of operating pressures up to 5000 psi.
They are typically used when accurate pressure
regulation is required and spool leakage is not critical.
Design Concepts and Features
■
Incorporates 150 micron stainless steel screen to
protect the main stage control orifice.
■
Low leakage, 2 to 5 in.3/min./1000 psi, dependent
on frame size.
■
Low hysteresis, less than ± 1%
■ Selection of spring adjustment ranges with low
adjustment effort.
3000
2000
3000
2000
1000
1000
0
20
RPKC-L*N
40
60
80 100
160
240
320 400
Flow = GPM
0
40
Flow = GPM
160 200
P = psi
5000
4000
3000
2000
1000
0
80
Flow = GPM
Relief Valves, Direct Acting
Typical Pressure Rise
RDDA-L*N
5000
5000
4000
4000
P = psi
P = psi
RDBA-L*N
3000
2000
1000
3000
2000
1000
0
2
4
6
8
Flow = GPM
10
12
RDFA-L*N
0
4000
P = psi
5000
4000
3000
2000
■
0
20
40
60
80 100
160
240
320 400
Flow = GPM
0
RDJA-L*N
5000
4000
3000
2000
80
Flow = GPM
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at a 4 GPM flow rate.
US Selected Assemblies Catalogue #999-901-192
3
80
120
40
50
2000
General Application Requirements
■
30
1000
0
■
20
Flow = GPM
3000
1000
■
10
RDHA-L*N
5000
1000
P = psi
Note: For both types of relief cartridge, any pressure at port 2 is
directly additive to the valve settings. In situations where absolute
pressure at port 1 is required; use RS*C-*** sequence cartridge or
RV*D, four port relief cartridge.
Performance Curves
P = psi
Applications
This patented, direct acting, differential area valve
with broad operating characteristics is adjustable to
5000 psi. Because of its exceptional performance, this
relief cartridge should be considered for applications
where fast response, dirt tolerance and leakage are
critical. Examples of this type of application would
include overshoot protection of fixed and variable
volume pumps and shock protection of actuators
(cylinders and motors).
Design Concepts and Features
■ Maximum leakage is 10 drops/min. at reseat.
■
Reseat equals 90% of cracking pressure for all five
frame sizes.
■
Not recommended for repeated adjustment because
of high adjustment effort.
40
Flow = GPM
160 200
TWO PORT RELIEF
Line Mounted Assemblies
TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS
(90 DEGREE BODIES)
PILOT OPERATED
ASSEMBLIES
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-12 GPM
Cavity T-162A
1.25
2
.62
0
1
Ports
1 and 2
Assembly
Model Code*
Ports
1 and 2
Mounting Holes:
.28 diameter through hole
1/4” NPTF
RPCC-LAN-AAA
2.00
3/8” NPTF
RPCC-LAN-AAB
1.72
SAE-4
RPCC-LAN-AAH
SAE-6
RPCC-LAN-AAI
L Control
1.80 Max.
2
1/4” NPTF
RDBA-LAN-AAA
3/8” NPTF
RDBA-LAN-AAB
SAE-4
RDBA-LAN-AAH
SAE-6
RDBA-LAN-AAI
1
.69
Assembly
Model Code*
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0 .28
1.58
0-25 GPM
2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.25
Cavity T-10A
1.50
.75
1
Ports
1 and 2
0
Assembly
Model Code*
1/2” NPTF
RPEC-LAN-FAC
3/4” NPTF
RPEC-LAN-FAD
SAE-10
RPEC-LAN-FAK
SAE-12
RPEC-LAN-FAL
Ports
1 and 2
Mounting Hole:
.34 diameter through hole
0
.28
L Control
2.35 Max.
2
1/2” NPTF
RDDA-LAN-FAC
3/4” NPTF
RDDA-LAN-FAD
SAE-10
RDDA-LAN-FAK
SAE-12
RDDA-LAN-FAL
1
1.44
Assembly
Model Code*
2.25
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
2.12
3.00
0-50 GPM
2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Cavity T-3A
1.50
.75
1
Ports
1 and 2
0
Assembly
Model Code*
Ports
1 and 2
Mounting Hole:
.42 diameter through hole
1/2” NPTF
RPGC-LAN-CAC
0
3/4” NPTF
RPGC-LAN-CAD
.38
SAE-10
RPGC-LAN-CAK
SAE-12
RPGC-LAN-CAL
L Control
2.46 Max.
2
1/2” NPTF
RDFA-LAN-CAC
3/4” NPTF
RDFA-LAN-CAD
SAE-10
RDFA-LAN-CAK
SAE-12
RDFA-LAN-CAL
1
1.25
Assembly
Model Code*
2.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
1.94
3.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
4
US Selected Assemblies Catalogue #999-901-192
TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS
(90 DEGREE/90 DEGREE 1.50” SAE C62 FLANGE PORT BODIES)
PILOT OPERATED
ASSEMBLIES
0-100 GPM
2
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
G
Cavity T-16A
2.25
1.12
1
0
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
RPIC-LAN-IAD
1” NPTF
RPIC-LAN-IAE
1 1/4” NPTF
RPIC-LAN-IAF
SAE-12
RPIC-LAN-IAL
SAE-16
RPIC-LAN-IAM
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1/4 NPTF
Gauge Port
1.13
Mounting Hole:
.42 diameter through hole
0
1.50
2
G
Assembly
Model Code*
3/4” NPTF
RDHA-LAN-IAD
1” NPTF
RDHA-LAN-IAE
1 1/4” NPTF
RDHA-LAN-IAF
SAE-12
RDHA-LAN-IAL
SAE-16
RDHA-LAN-IAM
1
1.88
G
3.00
1.00
0
2.62
0-200 GPM
2
L Control
3.19 Max.
Ports
1 and 2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
4.00
Cavity T-18A
2.75
1.38
1
0
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
RPKC-LAN-LAD
0
1” NPTF
RPKC-LAN-LAE
.62
1 1/4” NPTF
RPKC-LAN-LAF
SAE-12
RPKC-LAN-LAL
SAE-16
RPKC-LAN-LAM
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1/4 NPTF
Gauge Port
L Control
3.88 Max.
2
G
1
Ports
1 and 2
1 1/2” SAE C62
Assembly
Model Code*
RPKC-LAN-LA6
RDJA-LAN-LAD
1” NPTF
RDJA-LAN-LAE
1 1/4” NPTF
RDJA-LAN-LAF
SAE-12
RDJA-LAN-LAL
SAE-16
RDJA-LAN-LAM
G
3.50
0
1.09
2.81
4.62
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Cavity T-18A
1/4 NPTF Gauge Port
5.00
2.50
Ports
1 and 2
Assembly
Model Code*
1 1/2” SAE C62
RDJA-LAN-LA6
0
Mounting Hole: (opposite side)
.500 - 13 UNC x 19,0 mm deep. 2 places.
0
L Control
2
3.72 Max.
.50
2.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3.50
4.00
1
G
0 .62
3.03
4.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
Assembly
Model Code*
3/4” NPTF
1
2.12
0-200 GPM
2
Ports
1 and 2
Mounting Hole:
.42 diameter through hole
5
TWO PORT RELIEF
Line Mounted Assemblies
TWO PORT RELIEF
Line Mounted Assemblies
TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS
(THROUGH PORT BODIES)
PILOT OPERATED
ASSEMBLIES
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-12 GPM
Cavity T-162A
1.50
2
1
1
.75
G
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
RPCC-LAN-AEA
3/8” NPTF
RPCC-LAN-AEB
SAE-4
RPCC-LAN-AEH
SAE-6
RPCC-LAN-AEI
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
Ports
1 and 2
Mounting Holes: (opposite side)
.250-25 UNC x .50 deep. 2 places.
1/4 NPTF Gauge Port
0
L Control
2.08 Max.
2
G
.75
1/4” NPTF
RDBA-LAN-AEA
3/8” NPTF
RDBA-LAN-AEB
SAE-4
RDBA-LAN-AEH
SAE-6
RDBA-LAN-AEI
1
1.50
.88
0
1.83
0-25 GPM
Assembly
Model Code*
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.50
Cavity T-10A
1.75
2
1
1
G
Ports
1 and 2
.88
G
G
.25
0
Assembly
Model Code*
1/4” NPTF
Gauge Port.
2 places.
3/8” NPTF
RPEC-LAN-FEB
1/2” NPTF
RPEC-LAN-FEC
SAE-6
RPEC-LAN-FEI
SAE-8
RPEC-LAN-FEJ
Mounting Holes:
(opposite side)
.250-20 UNC-2B x
.50 deep. 2 places.
Ports
1 and 2
0
L Control
2.35 Max.
2
1
.88
Assembly
Model Code*
3/8” NPTF
RDDA-LAN-FEB
1/2” NPTF
RDDA-LAN-FEC
SAE-6
RDDA-LAN-FEI
SAE-8
RDDA-LAN-FEJ
1.06
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.75
0
.88
1.50 2.06
0-50 GPM
Cavity T-3A
2.00
1.75
2
1
1
G
Ports
1 and 2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.94
1.00
G
.25
0
Assembly
Model Code*
1/4 NPTF
Gauge Port.
2 places.
SAE-8
RPGC-LAN-CEJ
SAE-12
RPGC-LAN-CEL
Mounting Hole:
(opposite side)
.250-20 UNC-2B x
.50 deep.
0
L Control
2.47 Max.
2
1.25
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Ports
1 and 2
Assembly
Model Code*
SAE-8
RDFA-LAN-CEJ
SAE-12
RDFA-LAN-CEL
1
G
2.00
0
.75
2.19
3.25
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
6
US Selected Assemblies Catalogue #999-901-192
TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS
(THROUGH PORT BODIES)
PILOT OPERATED
ASSEMBLIES
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-100 GPM
2
Cavity T-16A
3.00
1
1
1.88
G
Ports
1 and 2
Assembly
Model Code*
1” NPTF
RPIC-LAN-IEE
1 1/4” NPTF
RPIC-LAN-IEF
SAE-12
RPIC-LAN-IEL
SAE-16
RPIC-LAN-IEM
0
Mounting Holes: (opposite side)
.375-16 UNC-2B x .62 deep. 2 places.
0
.38
L Control
2.39 Max.
Assembly
Model Code*
1” NPTF
RDHA-LAN-IEE
1 1/4” NPTF
RDHA-LAN-IEF
1
G
2
1.50
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Ports
1 and 2
1/4 NPTF Gauge Port
SAE-12
RDHA-LAN-IEL
SAE-16
RDHA-LAN-IEM
1
2.62
3.00
0
1.12
2.38 3.12
0-200 GPM
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
4.50
Cavity T-18A
3.50
3.00
2
G
1
1
G
1.75
.50
0
Ports
1 and 2
Assembly
Model Code*
1” NPTF
RPKC-LAN-LEE
1 1/4” NPTF
RPKC-LAN-LEF
SAE-12
RPKC-LAN-LEL
SAE-16
RPKC-LAN-LEM
Mounting Holes: (opposite side)
.375-16 UNC-2B x .62 deep. 2 places.
1/4 NPTF Gauge Port
0
2
Assembly
Model Code*
1” NPTF
RDJA-LAN-LEE
1 1/4” NPTF
RDJA-LAN-LEF
SAE-12
RDJA-LAN-LEL
SAE-16
RDJA-LAN-LEM
1
2.12
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
L Control
2.78 Max.
Ports
1 and 2
3.50
0
1.19
2.75 3.38
5.25
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
7
TWO PORT RELIEF
Line Mounted Assemblies
TWO PORT RELIEF
Line Mounted Assemblies
TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS
(2.00” SAE C61/C62 FLANGE PORT BODIES 2 CAVITIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-400 GPM
DIRECT ACTING ASSEMBLIES
Cavity T-18A
4.94
2
2.47
1
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
RPKC-LAN-XZY
0
Mounting Holes:
.375-16 UNC-2B x .62 deep.
2 places.
0
3.66
Max.
2
.94
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
RDJA-LAN-XZY
Ports
1 and 2
Assembly
Model Code*
2” SAE C62
RDJA-LAN-VTN
1
2.47
4.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
L Control
4.94
0
2.03
4.66
0-400 GPM
6.56
Cavity T-18A
5.94
2
2.97
1
0
Ports
1 and 2
Assembly
Model Code*
2” SAE C62
RPKC-LAN-VTN
Mounting Holes:
.375-16 UNC x .75 deep. 2 places.
0
3.38 Max.
2
1.06
1
2.97
L Control
4.88
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
2.28
4.88
7.12
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
8
US Selected Assemblies Catalogue #999-901-192
TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS
(CROSS-PORT BODIES, 2 CAVITIES)
Cross-port relief assemblies are used to protect system components
against hydraulic and structural damage which can be caused by the
sudden stopping of an inertial load. These assemblies also protect
“swing” circuits and other bi-directional installations against possible
surges and cavitation.
PILOT OPERATED
ASSEMBLIES
Sun offers a series of cross-port relief assemblies for line mounting
which are shown below, as well as a variety of single and dual models
in sandwich bodies to simplify circuitry when using ISO 02, ISO 05,
ISO 07 and ISO 08 solenoid valves.
Go to www.sunhydraulics.com
for more product information and pricing.
0-12 GPM
1
DIRECT ACTING
ASSEMBLIES
Cavity T-162A
1
1.25
2
2
Ports
1 and 2
0
Assembly
Model Code*
1/4” NPTF
RPCC-LAN-AYA
3/8” NPTF
RPCC-LAN-AYB
SAE-4
RPCC-LAN-AYH
SAE-6
RPCC-LAN-AYI
0
Mounting Holes:
.28 diameter through hole
2 places
1
2
Ports
1 and 2
L Control
2.05 Max.
Assembly
Model Code*
1/4” NPTF
RDBA-LAN-AYA
3/8” NPTF
RDBA-LAN-AYB
SAE-4
RDBA-LAN-AYH
SAE-6
RDBA-LAN-AYI
2.05 Max.
1
2
2.50
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.70
0
1.38 2.05
0-25 GPM
1
1
2
2
Ports
1 and 2
RPEC-LAN-YFB
1/2” NPTF
RPEC-LAN-YFC
SAE-6
RPEC-LAN-YFI
SAE-8
RPEC-LAN-YFJ
Cavity T-10A
1.50
0
Assembly
Model Code*
3/8” NPTF
2.75
1
2.31
0
3.50
3.00
.97 1.75 2.53
2
G
Assembly
Model Code*
3/4” NPTF
RPGC-LAN-YCD
1” NPTF
RPGC-LAN-YCE
0
SAE-12
RPGC-LAN-YCL
2.00 Max.
SAE-16
RPGC-LAN-YCM
SAE-6
RDDA-LAN-YFI
SAE-8
RDDA-LAN-YFJ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3.50
G2
2
1
Mounting Holes: (opposite side)
.375-16 UNC-2B x .62 deep. 2 places.
Ports
1 and 2
RDDA-LAN-YFB
RDDA-LAN-YFC
2
1
.50
0
3/8” NPTF
1/2” NPTF
Cavity T-3A
G1
2
Assembly
Model Code*
2
1
0-50 GPM
1
L Control
2.26 Max.
2
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1
Ports
1 and 2
Mounting Holes:
.34 diameter through hole.
2 places.
2.26 Max.
.44
G
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.75
1/4” NPTF Gauge Ports
L Control
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
RDFA-LAN-YCD
1” NPTF
RDFA-LAN-YCE
SAE-12
RDFA-LAN-YCL
SAE-16
RDFA-LAN-YCM
2.00
Max.
3.50
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
0
1.44
2.94
4.44 5.88
Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
9
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
TWO PORT RELIEF
Line Mounted Assemblies
TWO PORT RELIEF
Line Mounted Assemblies
TWO PORT PRESSURE REGULATING RELIEF APPLICATIONS
(CROSS-PORT/CROSS-PORT, 1.50” SAE C61/C62 FLANGE PORT BODIES, 2 CAVITIES)
PILOT OPERATED
ASSEMBLIES
0-100 GPM
G
1
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
Cavity T-16A
1
4.00
3.50
2
1
G2
G1
2
2
Ports
1 and 2
Mounting Holes: (opposite side)
.375-16 UNC-2B x .62 deep.
2 places.
Assembly
Model Code*
1 1/4” NPTF
RPIC-LAN-YIF
SAE-20
RPIC-LAN-YIN
2
1
.50
0
G
Ports
1 and 2
1 1/4” NPTF
RDHA-LAN-YIF
SAE-20
RDHA-LAN-YIN
1/4” NPTF Gauge Ports
0
Assembly
Model Code*
L Control
2.69
Max.
2.69 Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1
2
0
1.88
3.88
0-200 GPM
G
1
4.00
2
G
5.88
7.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Cavity T-18A
4.94
3.97
1
.97
1
2
G2
G1
2
0
Ports
1 and 2
Assembly
Model Code*
1 1/2” SAE C61
RPKC-LAN-YLR
Mounting Holes: (opposite side)
.375-16 UNC-2B x .62 deep. 2 places.
1/4” NPTF Gauge Ports
0
Ports
1 and 2
Assembly
Model Code*
1 1/2” SAE C61
RDJA-LAN-YLR
L Control
3.63
Max.
3.63
Max.
5.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1
2
4.00
0-200 GPM
G
1
2.00
0
5.94
5.47
6.00
2
G1
2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Cavity T-18A
1
G
8.00
G2
1
2
.47
0
Ports
1 and 2
Assembly
Model Code*
1 1/2” SAE C62
RPKC-LAN-YL6
Mounting Holes: (opposite side)
.375-16 UNC-2B x .62 deep. 2 places.
1/4” NPTF Gauge Ports
0
Ports
1 and 2
Assembly
Model Code*
1 1/2” SAE C62
RDJA-LAN-YL6
L Control
3.88 Max.
3.88
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
6.00
0
1.88
3.88
5.88
7.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
10
US Selected Assemblies Catalogue #999-901-192
Three Port Relief Assemblies
Cartridge Type
Page
3
2
Pilot Operated with Vent
12
1
Line Mounted Assemblies
(Body Type)
3
2
1
2
1
90 Degree
90 Degree 1.50” SAE C62 Flange Port
90 Degree 2.00” SAE C61/C62 Flange Port, 2 Cavities
14
15
16
Solenoid Operated with Vented Relief
Solenoid Operated, Flange Mounted with Vented Relief
17
18
1
G
US Selected Assemblies Catalogue #999-901-192
11
THREE PORT RELIEF
Relief Valves
PILOT OPERATED WITH VENT
3
2
1
7.5 GPM
RVBA – LAN
T - 163A
1.22
3/4”
2.55
2.63
2.77
15 GPM
RVCA – LAN
T - 11A
1.38
7/8”
2.50
2.56
2.75
30/35
30 GPM
RVEA – LAN
T - 2A
1.38
1 1/8”
2.81
2.88
3.06
45/50
60 GPM
RVGA – LAN
T - 17A
1.81
1 1/4”
3.28
3.31
3.53
150/160
120 GPM
RVIA – LAN
T - 19A
2.50
1 5/8”
3.94
4.09
4.19
350/375
OPTION ORDERING INFORMATION
Full Adjustment 5 Turns
+
-
Nominal
Capacity
c
b
3
Vent
Cavity
a
Control**
Adjustment Range
Seal
B 7.5 GPM*
L Standard Screw
A 100 - 3000 psi
N Buna-N
C 15 GPM
C Tamper Resistant
W 150 - 4500 psi
V Viton
E 30 GPM
K Handknob
B 50 - 1500 psi
G 60 GPM
C 150 - 6000 psi
I
N 60 - 800 psi
120 GPM
Q 60 - 400 psi
a
Inlet 1
K
RV ✱ A – ✱ ✱ ✱
Locating
Shoulder
2
Outlet
Cartridge Dimensions
c
b
L
C
Installation
Torque
(lb. ft.)
25/30
Capacity
Typical
Cartridge
Model Code
** See page 244 for information
on Control Options
12
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
US Selected Assemblies Catalogue #999-901-192
THREE PORT RELIEF
TECHNICAL TIPS / PERFORMANCE CURVES
Relief Valves, Pilot Operated with Vent
Typical Pressure Rise
Vented Pressure
RVBA-L*N
200
5000
P = psi
P = psi
4000
3000
2000
1000
0
2
RVCA-L*N
4
6
Flow = GPM
8
100
A, B, C, N, Q & W
50
0
2
4
6
8
10
12
16
20
24
32
40
48
64
80
Flow = GPM
200
5000
4000
P = psi
P = psi
150
10
3000
2000
1000
0
5
10
15
Flow = GPM
20
150
C&W
100
A
B, N, Q
50
25
0
4
8
Flow = GPM
RVEA-L*N
5000
200
4000
150
P = psi
Note: Any pressure at port 2 is additive to the pressure setting of the
valve. If absolute system pressure must be regulated at port 1 and
variable pressure is present at port 2, consider using the 4 port
RV*D-*** series where an independent drain port is provided.
Performance Curves
P = psi
Applications
Ventable, pilot operated relief valves incorporate an
additional port for remote control.
■
To provide remote adjustment of the main
cartridge through the use of the RBAC-*** pilot
cartridge or other suitable device.
■
To unload the main relief valve by opening the vent
port with a 2-way solenoid valve (DAAA-***).
Normal relief operation is activated by blocking
the bypass pilot flow.
Design Concepts and Features
■
Incorporates 150 micron stainless steel screen to
protect the main stage control orifice.
■
Low leakage, 2 to 5 in.3/min./1000 psi, dependent
on frame size.
■ Control pilot flow .05 to .07 GPM, dependent on
frame size.
■
Low hysteresis, less than ± 1%
■
Low pressure drop when unloaded.
3000
2000
1000
0
10
20
30
Flow = GPM
40
100
C&W
A
50
50
B, N, Q
0
8
16
Flow = GPM
RVGA-L*N
200
5000
P = psi
P = psi
4000
3000
2000
1000
0
20
40
60
Flow = GPM
80
150
C&W
100
A
B, N, Q
50
100
0
16
32
Flow = GPM
5000
200
4000
150
P = psi
P = psi
RVIA-L*N
3000
2000
C&W
100
A
B, N, Q
50
1000
0
20
40
60
Flow = GPM
80
100
0
32
General Application Requirements
■
■
■
■
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at a 4 GPM flow rate.
US Selected Assemblies Catalogue #999-901-192
13
64
96
Flow = GPM
128 160
THREE PORT RELIEF
Line Mounted Assemblies
THREE PORT PRESSURE REGULATING RELIEF APPLICATIONS
(90 DEGREE BODIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-7.5 GPM
Cavity T-163A
3
2
1.00
.50
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1/4” NPTF
1/4” NPTF
RVBA-LAN-JCA
3/8” NPTF
1/4” NPTF
RVBA-LAN-JCB
SAE-4
SAE-4
RVBA-LAN-JCH
SAE-6
SAE-4
RVBA-LAN-JCI
Mounting Holes:
.28 diameter through hole
2 places.
0
.28
L Control
1.91 Max.
2
1
.97
3
2.00
1.31
0
2.14 2.59
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-15 GPM
Cavity T-11A
3
1.25
2
.62
0
1
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
RVCA-LAN-ECB
1/2” NPTF
1/4” NPTF
RVCA-LAN-ECC
SAE-4
SAE-4
RVCA-LAN-ECH
SAE-6
SAE-6
RVCA-LAN-ECI
SAE-8
SAE-6
RVCA-LAN-ECJ
Mounting Holes:
.34 diameter through hole
2 places.
.44
2.56
0
.38
L Control
1.81 Max.
2
1
1.25
3
2.50
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
1.56
0
2.53 3.00
0-30 GPM
3
2
Cavity T-2A
1.50
.75
0
1
Ports
1 and 2
Port 3
Assembly
Model Code*
1/2” NPTF
1/4” NPTF
RVEA-LAN-BCC
3/4” NPTF
1/4” NPTF
RVEA-LAN-BCD
SAE-6
SAE-6
RVEA-LAN-BCI
SAE-8
SAE-6
RVEA-LAN-BCJ
Mounting Holes:
.42 diameter through hole
2 places.
.50
2.75
0
L Control
2.00 Max.
2
.50
1
1.62
3
3.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0
1.72
2.66 3.25
NOTES: Page 12 for cartridge model RV*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
14
US Selected Assemblies Catalogue #999-901-192
THREE PORT PRESSURE REGULATING RELIEF APPLICATIONS
(90 DEGREE/90 DEGREE 1.50” SAE C62 FLANGE PORT BODIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-60 GPM
3
Cavity T-17A
2.25
2
2.12
0
1
Ports
1 and 2
Port 3
Assembly
Model Code*
3/4” NPTF
1/4” NPTF
RVGA-LAN-HCD
1” NPTF
1/4” NPTF
RVGA-LAN-HCE
1 1/4” NPTF
1/4” NPTF
RVGA-LAN-HCF
SAE-12
SAE-6
RVGA-LAN-HCL
SAE-16
SAE-6
RVGA-LAN-HCM
Mounting Holes:
.42 diameter through hole
2 places.
.75
3.50
0
L Control
2.16 Max.
2
.75
1
2.00
3
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
4.00
2.12
0
0-120 GPM
3
3.50 4.25
Cavity T-19A
3.00
2
1.50
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
RVIA-LAN-KCE
1 1/4” NPTF
1/4” NPTF
RVIA-LAN-KCF
SAE-20
SAE-6
RVIA-LAN-KCN
Mounting Holes:
.42 diameter through hole
2 places.
.50
0
.50
4.50
L Control
2.78 Max.
2
1
2.25
3
4.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
2.47
0
0-120 GPM
3
4.25 5.00
Cavity T-19A
4.50
2
2.25
1
0
Ports
1 and 2
1 1/2” SAE C62
Port 3
SAE-6
Assembly
Model Code*
RVIA-LAN-KC6
0
.47
Mounting Holes:
.375-16 UNC-2B x .62 deep.
2 places.
1
2.47
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
L Control
2.78 Max
2
3
4.47
4.94
0
2.41
4.19 4.94
NOTES: Page 12 for cartridge model RV*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
15
THREE PORT RELIEF
Line Mounted Assemblies
THREE PORT RELIEF
Line Mounted Assemblies
THREE PORT PRESSURE REGULATING RELIEF APPLICATIONS
(90 DEGREE 2.00” SAE C61/C62 FLANGE PORT BODIES, 2 CAVITIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-240 GPM
3
Cavity T-19A
5.94
2
2.97
1
Ports
1 and 2
Port 3
Assembly
Model Code*
2” SAE C61
SAE-6
RVIA-LAN-XZZ
0
Mounting Holes:
.50-13 UNC-2B x .87 deep.
2 places.
0
2
.97
2.77
Max.
3
1
2.88
4.97
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
5.94
0
1.97
0-240 GPM
3
4.25 6.03 6.75
Cavity T-19A
5.94
2
2.97
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
2” SAE C62
SAE-6
RVIA-LAN-Z8Z
Mounting Holes:
.500-13 UNC-2B x .87 deep. 2 places.
L Control
0
2.78 Max.
1.06
2
1
2.97
3
4.88
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
5.94
0
2.26
4.97 6.78 7.50
NOTES: Page 12 for cartridge model RV*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
16
US Selected Assemblies Catalogue #999-901-192
THREE PORT PRESSURE REGULATING RELIEF APPLICATIONS
(SOLENOID OPERATED BODIES WITH VENTED RELIEF)
Suitable for operation
up to 5000 psi
PILOT OPERATED
ASSEMBLIES
0-15 GPM
Solenoid Valve
Normally Closed
Solenoid Valve
Normally Open
Go to www.sunhydraulics.com
for more product information and pricing.
Cavity T-11A
RVCA
1
1
L Control
1.82
Max.
2
2
1
2.91
Max.
DAAA-M*N
1
G
G
3.50
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
XRCA-LAN-*A
3/8” NPTF
XRCA-LAN-*B
1/2” NPTF
XRCA-LAN-*C
SAE-6
XRCA-LAN-*I
SAE-8
XRCA-LAN-*J
2
1/4 NPTF
Gauge Port
G
1
2.00
Mounting Holes:
.375-16 UNC-2B
x .63 deep.
.69
0
2.78
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.03
.88
0
0
Assembly Order:
760 – ✱ ✱ ✱
✱
Port
Style / Type
See above.
DAAA Spool
Configuration
H Normally
Open
Coils must be ordered
separately. See page 248
for Connector Options
Coil
Configuration
ISO/DIN
206 6 VDC
212 12 VDC
224 24 VDC
211 115 VAC
223 230 VAC
C Normally
Closed
0-30 GPM
Solenoid Valve
Normally Closed
Solenoid Valve
Normally Open
0
Solenoid Coil Order:
XRCA – ✱ ✱ ✱ – ✱
See Page 12
for RVCA
Options
1.00
2.00
Cavity T-2A
RVEA
L Control
2.00
Max.
2
2
1
1
2.91
Max.
DAAA-M*N
1
1
3.75
G
G
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
XREA-LAN-*A
3/8” NPTF
XREA-LAN-*B
1/2” NPTF
XREA-LAN-*C
3/4” NPTF
XREA-LAN-*D
SAE-8
XREA-LAN-*J
SAE-12
XREA-LAN-*L
.88
1
G
2.12
Mounting Holes:
.375-16 UNC-2B
x .63 deep.
0
2.50
3.50
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.06
2.00
1.00
0
Solenoid Coil Order:
XREA – ✱ ✱ ✱ – ✱
See Page 12
for RVEA
Options
0
0
Assembly Order:
DAAA Spool
Configuration
H Normally
Open
760 – ✱ ✱ ✱
✱
Port
Style / Type
See above.
C Normally
Closed
NOTES: Page 12 for cartridge model RV*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
2
1/4 NPTF
Gauge Port
17
Coils must be ordered
separately. See page 248
for Connector Options
Coil
Configuration
206
212
224
211
223
ISO/DIN
6 VDC
12 VDC
24 VDC
115 VAC
230 VAC
THREE PORT RELIEF
Line Mounted Assemblies
THREE PORT RELIEF
Line Mounted Assemblies
THREE PORT PRESSURE REGULATING RELIEF APPLICATIONS
(SOLENOID OPERATED, FLANGE MOUNTED BODIES WITH VENTED RELIEF)
Suitable for operation
up to 5000 psi
PILOT OPERATED
ASSEMBLIES
0-60 GPM
Solenoid Valve
Normally Closed
Solenoid Valve
Normally Open
Go to www.sunhydraulics.com
for more product information and pricing.
Cavity T-17A
RVGA
2
2
1
1
1
1
5.00
G
G
2.91
Max.
L Control
2.37
Max.
1/4” NPTF
Gauge Port
Ports
1 and 2
Assembly
Model Code*
1” SAE C61
XRGA-LAN-*P
G
1.75
1.31
1
3.09
2
Mounting Holes:
.375-16 UNC-2B
x .62 deep.
0
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.62
3.62
4.00
.38
Assembly Order:
760 – ✱ ✱ ✱
✱
Port
Style / Type
DAAA Spool
Configuration
H Normally
Open
See above.
0
Coils must be ordered
separately. See page 248
for Connector Options
Coil
Configuration
206
212
224
211
223
C Normally
Closed
0-120 GPM
Solenoid Valve
Normally Closed
Solenoid Valve
Normally Open
1.25
Solenoid Coil Order:
XRGA – ✱ ✱ ✱ – ✱
See Page 12
for RVGA
Options
2.50
0
ISO/DIN
6 VDC
12 VDC
24 VDC
115 VAC
230 VAC
Cavity T-19A
RVIA
1
1
L Control
2.78
Approx.
2
2
1
2.88
Max.
DAAA-M*N
1
7.62
G
G
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
XRIA-LAN-*S
2” SAE Code 62
5.12
4 Bolt Flange Pattern
Typ. (3) Places
.375-16 UNC-2B
x .88 deep.
2 places
2.38
Mounting Holes:
.375-16 UNC-2B
x .62 deep.
12 places
0
0
1/4 NPTF
Gauge
Port
G
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
5.94
5.47
2.97
.47
0
Assembly Order:
XRIA – ✱ ✱ ✱ – ✱
See Page 12
for RVIA
Options
2.97
0
5.94
Solenoid Coil Order:
760 – ✱ ✱ ✱
✱
Port
Style / Type
See above.
DAAA Spool
Configuration
H Normally
Open
C Normally
Closed
Coils must be ordered
separately. See page 248
for Connector Options
Coil
Configuration
ISO/DIN
206 6 VDC
212 12 VDC
224 24 VDC
211 115 VAC
223 230 VAC
NOTES: Page 12 for cartridge model RV*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
18
US Selected Assemblies Catalogue #999-901-192
Sequence Assemblies
Cartridge Type
Page
3
2
Pilot Operated
20
Direct Acting
20
Direct Acting with Reverse Free Flow Check
28
1
3
2
1
3
2
1
Line Mounted Assemblies
(Body Type)
3
2
90 Degree
22
90 Degree with Reverse Free Flow Check
24
90 Degree with Reverse Free Flow Check, 2 Cavities
26
90 Degree
30
1
3
1
2
G
VB
C2B
C2A
C1B
C1A
VA
3
2
1
US Selected Assemblies Catalogue #999-901-192
19
SEQUENCE
Sequence Valves
PILOT OPERATED
3
2
1
7.5 GPM
RSBC – LAN
T - 163A
1.22
3/4”
2.55
2.63
2.77
15 GPM
RSDC – LAN
T - 11A
1.38
7/8”
2.50
2.56
2.75
30/35
30 GPM
RSFC – LAN
T - 2A
1.38
1 1/8”
2.81
2.88
3.06
45/50
60 GPM
RSHC – LAN
T - 17A
1.81
1 1/4”
3.28
3.31
3.53
150/160
120 GPM
RSJC – LAN
T - 19A
2.50
1 5/8”
3.94
4.09
4.19
350/375
OPTION ORDERING INFORMATION
Cavity
Nominal
Capacity
c
3
Drain
a
Control**
Adjustment Range
Seal
B 7.5 GPM*
L Standard Screw
A 100 - 3000 psi
N Buna-N
D 15 GPM
C Tamper Resistant
W 150 - 4500 psi
V Viton
F 30 GPM
K Handknob
B 50 - 1500 psi
H 60 GPM
C 150 - 6000 psi
J 120 GPM
N 60 - 800 psi
Q 60 - 400 psi
Locating
Shoulder
a
2
Sequence
K
RS ✱ C – ✱ ✱ ✱
Full Adjustment 5 Turns
+
-
b
Cartridge Dimensions
c
b
L
C
Installation
Torque
(lb. ft.)
25/30
Capacity
Typical
Cartridge
Model Code
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
** See page 244 for information
on Control Options
Inlet 1
DIRECT ACTING
3
2
Cartridge Dimensions
c
b
L
15 GPM
SXCA – LAN
T - 11A
1.38
7/8”
3.09
3.15
Installation
Torque
(lb. ft.)
30/35
30 GPM
SXEA – LAN
T - 2A
1.38
1 1/8”
3.47
3.53
45/50
Capacity
Typical
Cartridge
Model Code
Cavity
a
C
1
OPTION ORDERING INFORMATION
SX ✱ A – ✱ ✱ ✱
Full Adjustment 4 Turns
+
-
Nominal
Capacity
Control**
C 15 GPM
L Standard Screw
E 30 GPM
C Tamper Resistant
Seal
A 500 - 3000 psi
N Buna-N
W 800 - 4500 psi
V Viton
B 300 - 1500 psi
c
b
Adjustment Range
C 2000 - 6000 psi
D 200 - 800 psi
3
Drain
2
Sequence
Inlet 1
Locating
Shoulder
a
** See page 244 for information
on Control Options
20
Adjustment Range Options:
A, B, and W are standard set at 1000 psi.
C Option is standard set at 2000 psi.
D Option is standard set at 400 psi
Customer may specify pressure setting.
US Selected Assemblies Catalogue #999-901-192
TECHNICAL TIPS / PERFORMANCE CURVES
Performance Curves
Pressure Drop-full Sequence
RSBC-L*N
RSDC-L*N
200
150
P = psi
P = psi
200
100
50
0
2
4
6
8
150
100
50
10
RSFC-L*N
10
15
20
40
60
80
Flow = GPM
RSHC-L*N
200
150
150
P = psi
200
100
50
0
5
0
Flow = GPM
P = psi
Applications
Pilot operated sequence cartridges are similar to
relief valves, but with an additional third port, to drain
the spring chamber.
■
May be used to regulate pressure more accurately
than relief valve, as pressure is regulated on an
absolute basis.
■
To control the sequence of two or more cylinders
or motors while maintaining the pressure on the
actuator that moves first.
Design Concepts and Features
■
Exceptionally flat pressure control over a wide
range of settings.
■ Low hysteresis and spool leakage:
2 to 5 in.3/min./1000 psi dependent on frame size.
■
Wide selection of spring ranges to optimize
adjustment sensitivity.
■ Pilot flow will continue to increase when pilot
section opens as pressure at port 1 increases above
setting. Maximum Pilot Flow May be 150 in.3/min.
SEQUENCE
Sequence Valves, Pilot Operated
10
20
30
Flow = GPM
100
40
50
20
0
Flow = GPM
RSJC-L*N
P = psi
200
150
100
50
0
40
80
120
Flow = GPM
160
Sequence Valves, Direct Acting
Performance Curves
Pressure Drop-full Sequence
SXCA-L*N
SXEA-L*N
400
400
300
300
P = psi
P = psi
Applications
The direct acting sequence cartridges are
interchangeable with the pilot operated models and
may be used as an alternative to the pilot operated
version.
Design Concepts and Features
■ Low hysteresis and low leakage on closing. Valve
reseats with leakage less than 5 drops./min.
■
Reseat at 85% of cracking pressure.
■
Direct acting design provides fast opening and
closing.
■ Zero pilot flow (however, the spring chamber drain
must not be plugged). See Note.
200
100
0
5
10
15
200
100
0
Note: For both types of sequence cartridge, any pressure at port 3 is
directly additive to the valve setting.
General Application Requirements
■
■
■
■
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at a 4 GPM flow rate.
US Selected Assemblies Catalogue #999-901-192
21
10
20
30
SEQUENCE
Line Mounted Assemblies
THREE PORT PRESSURE SEQUENCING APPLICATIONS
(90 DEGREE BODIES)
PILOT OPERATED
ASSEMBLIES
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-7.5 GPM
Cavity T-163A
3
2
1.00
.50
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1/4” NPTF
1/4” NPTF
RSBC-LAN-JCA
3/8” NPTF
1/4” NPTF
RSBC-LAN-JCB
SAE-4
SAE-4
RSBC-LAN-JCH
SAE-6
SAE-4
RSBC-LAN-JCI
Mounting Holes:
.28 diameter through hole
2 places.
0
.28
L Control
1.91 Max.
2
1
.97
3
2.00
1.31
0
2.14 2.59
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-15 GPM
Cavity T-11A
3
2
1.25
.62
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
RSDC-LAN-ECB
1/2” NPTF
1/4” NPTF
RSDC-LAN-ECC
SAE-4
SAE-4
RSDC-LAN-ECH
SAE-6
SAE-6
RSDC-LAN-ECI
SAE-8
SAE-6
RSDC-LAN-ECJ
Mounting Holes:
.34 diameter through hole
2 places.
0
.38
L Control
2.40 Max.
2
1
1.25
3
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
SXCA-LAN-ECB
1/2” NPTF
1/4” NPTF
SXCA-LAN-ECC
SAE-4
SAE-4
SXCA-LAN-ECH
SAE-6
SAE-6
SXCA-LAN-ECI
SAE-8
SAE-6
SXCA-LAN-ECJ
2.50
1.56
0
2.53 3.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-30 GPM
Cavity T-2A
3
2
1.50
.75
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
3/4” NPTF
1/4” NPTF
RSFC-LAN-BCD
SAE-6
SAE-6
RSFC-LAN-BCI
SAE-8
SAE-6
RSFC-LAN-BCJ
SAE-12
SAE-6
RSFC-LAN-BCL
0
Mounting Holes:
.42 diameter through hole
2 places.
L Control
2.66 Max.
2
.50
1
1.62
Ports
1 and 2
Port 3
Assembly
Model Code*
3/4” NPTF
1/4” NPTF
SXEA-LAN-BCD
SAE-6
SAE-6
SXEA-LAN-BCI
SAE-8
SAE-6
SXEA-LAN-BCJ
SAE-12
SAE-6
SXEA-LAN-BCL
3
3.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0
1.72
2.66 3.25
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 20 for cartridge models RS*C-*** and SX*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
22
US Selected Assemblies Catalogue #999-901-192
THREE PORT PRESSURE SEQUENCING APPLICATIONS
(90 DEGREE BODIES)
PILOT OPERATED
ASSEMBLIES
3
Go to www.sunhydraulics.com
for more product information and pricing.
0-60 GPM
Cavity T-17A
2.25
2
2.12
0
1
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
RSHC-LAN-HCE
1 1/4” NPTF
1/4” NPTF
RSHC-LAN-HCF
SAE-12
SAE-6
RSHC-LAN-HCL
SAE-16
SAE-6
RSHC-LAN-HCM
0
Mounting Holes:
.42 diameter through hole
2 places.
L Control
2.16 Max.
2
.75
1
2.00
3
4.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
2.12
0
0-120 GPM
3.50 4.25
Cavity T-19A
3
3.00
2
1.50
1
Ports
1 and 2
0
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
RSJC-LAN-KCE
1 1/4” NPTF
1/4” NPTF
RSJC-LAN-KCF
Mounting Holes:
.42 diameter through hole
2 places.
0
.50
L Control
2.78 Max.
2
1
2.25
3
4.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0
2.47
4.25 5.00
NOTES: Page 20 for cartridge models RS*C-*** and SX*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
23
SEQUENCE
Line Mounted Assemblies
SEQUENCE
Line Mounted Assemblies
THREE PORT PRESSURE SEQUENCING APPLICATIONS
(BODIES WITH REVERSE FREE FLOW CHECK)
PILOT OPERATED
ASSEMBLIES
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-7.5 GPM
Cavity T-163A
3
1
2
.70
2.56
1.00
G
0
Mounting Holes:
.28 diameter through hole, 2 places.
Ports
1 and 2
Port 3
Assembly
Model Code*
1/4” NPTF
1/4” NPTF
RSBC-LAN-J6*
3/8” NPTF
1/4” NPTF
RSBC-LAN-J6*
SAE-4
SAE-4
RSBC-LAN-J6*
SAE-6
SAE-4
RSBC-LAN-J6*
0
.25
L Control
1.92 Max.
3
1
CXAD-XCN
.63
G
2
3.00
1.50
0
3.00
1/4 NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-15 GPM
Cavity T-11A
3
1
2
1.25
G
Ports
1 and 2
Port 3
0
CXDA-XCN
Assembly
Model Code*
1/4 NPTF Gauge Port
Mounting Holes:
.34 diameter through hole, 2 places.
0
3/8” NPTF
1/4” NPTF
RSDC-LAN-E6B
1/2” NPTF
1/4” NPTF
RSDC-LAN-E6C
1.00
SAE-6
SAE-6
RSDC-LAN-E6I
1.50
SAE-8
SAE-6
RSDC-LAN-E6J
SAE-10
SAE-6
RSDC-LAN-E6K
L Control
2.28 Max.
3
1
G
2
.59
3.00
0
.91
2.06
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
SXCA-LAN-E6B
1/2” NPTF
1/4” NPTF
SXCA-LAN-E6C
SAE-6
SAE-6
SXCA-LAN-E6I
SAE-8
SAE-6
SXCA-LAN-E6J
SAE-10
SAE-6
SXCA-LAN-E6K
3.03 3.62
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-30 GPM
Cavity T-2A
3
1
2
1.50
G
Ports
1 and 2
Port 3
0
CXFA-XCN
Assembly
Model Code*
Mounting Holes:
.28 diameter through hole, 2 places.
3/8” NPTF
1/4” NPTF
RSFC-LAN-B6B
0
2.75
1/2” NPTF
1/4” NPTF
RSFC-LAN-B6C
2.00
3/4” NPTF
1/4” NPTF
RSFC-LAN-B6D
SAE-8
SAE-6
RSFC-LAN-B6J
SAE-10
SAE-6
RSFC-LAN-B6K
1/4 NPTF Gauge Port
1
G
.66
3.00 0
.81 1.00 2.19
L Control
2.39 Max.
3
2
3.56
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
SXEA-LAN-B6B
1/2” NPTF
1/4” NPTF
SXEA-LAN-B6C
3/4” NPTF
1/4” NPTF
SXEA-LAN-B6D
SAE-8
SAE-6
SXEA-LAN-B6J
SAE-10
SAE-6
SXEA-LAN-B6K
4.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 20 for cartridge models RS*C-*** and SX*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
24
US Selected Assemblies Catalogue #999-901-192
THREE PORT PRESSURE SEQUENCING APPLICATIONS
(BODIES WITH REVERSE FREE FLOW CHECK)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-60 GPM
Cavity T-17A
3
1
2
1.25
G
0
CXDA-XCN
1/4” NPTF Gauge Port
Mounting Holes:
.34 diameter through hole, 2 places.
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
RSHC-LAN-H6E
1 1/4” NPTF
1/4” NPTF
RSHC-LAN-H6F
1.00
SAE-12
SAE-6
RSHC-LAN-H6L
1.50
SAE-16
SAE-6
RSHC-LAN-H6M
0
L Control
2.28 Max.
3
1
G
2
.59
3.00
.91
0
2.06
3.03 3.62
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-120 GPM
Cavity T-19A
3
1
2
1/4 NPTF Gauge Port
CXJA-XCN
0
G
3.00
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
RSJC-LAN-K6E
1 1/4” NPTF
1/4” NPTF
RSJC-LAN-K6F
Mounting Holes:
.42 diameter through hole, 2 places.
6.00
1
4.00
1.43
2.72
Max.
3
G
L Control
2
0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0 .50
1.88
4.41
6.22 7.00
NOTES: Page 20 for cartridge models RS*C-*** and SX*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
25
SEQUENCE
Line Mounted Assemblies
SEQUENCE
Line Mounted Assemblies
THREE PORT DUAL PRESSURE SEQUENCING APPLICATIONS
(2 CAVITY BODIES WITH REVERSE FREE FLOW CHECKS)
The line-mounted dual sequencing assembly can be used in applications where two hydraulic cylinders are to be operated in a particular sequence
when both extending and retracting. The block eliminates a great deal of pipework when compared to using conventional line mounted valves.
PILOT OPERATED
ASSEMBLIES
0-15 GPM
C2B
C2A
Cavity T-11A
VB
2.50
C1B
C1B
C1A
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
VA
CXDA-XCN
2 places.
C2B
C1A
C2A
0
All Ports
Assembly
Model Code*
3/8” NPTF
RSDC-LAN-E8B
1/2” NPTF
RSDC-LAN-E8C
SAE-6
RSDC-LAN-E8I
SAE-8
RSDC-LAN-E8J
All Ports
Mounting Holes:
.34 diameter through hole
2 places.
0
.31
2.41
L Control
2.41 Max.
VA
VB
1.06
2.94
Assembly
Model Code*
3/8” NPTF
SXCA-LAN-E8B
1/2” NPTF
SXCA-LAN-E8C
SAE-4
SXCA-LAN-E8I
SAE-6
SXCA-LAN-E8J
2.50
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
0-30 GPM
C2B
C2A
C1B
C1A
VB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
4.00
Cavity T-2A
3.00
C1
B
C1
A
VA
CXFA-XCN
2 places.
C2
B
C2
A
0
All Ports
Assembly
Model Code*
1/2” NPTF
RSFC-LAN-B8C
3/4” NPTF
RSFC-LAN-B8D
SAE-8
RSFC-LAN-B8J
.25
0
All Ports
Mounting Holes:
.34 diameter through hole
2 places.
L Control
2.75 Max.
2.75
VA
Assembly
Model Code*
1/2” NPTF
SXEA-LAN-B8C
3/4” NPTF
SXEA-LAN-B8D
SAE-8
SXEA-LAN-B8J
VB
3.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.06
0
3.31
0-60 GPM
C2B
C2A
C1B
C1A
VB
4.00
Cavity T-17A
5.00
C1B
VA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
C1A
CXHA-XCN
2 places.
C2B
C2A
0
All Ports
Assembly
Model Code*
1” NPTF
RSHC-LAN-H8E
1 1/4” NPTF
RSHC-LAN-H8F
Mounting Holes: (opposite side)
.42 diameter through hole, 2 places.
0
L Control
VA
2.28
Max.
2.28
VB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
5.00
0
1.56
4.56 6.12
NOTES: Page 20 for cartridge models RS*C-*** and SX*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
26
US Selected Assemblies Catalogue #999-901-192
US Selected Assemblies Catalogue #999-901-192
SEQUENCE
NOTES
27
SEQUENCE
Sequence Valves
DIRECT ACTING WITH REVERSE FREE FLOW CHECK
3
Capacity
2
1
a
C
Installation
Torque
(lb. ft.)
35/30
15 GPM
SCCA – LAN
T - 11A
1.38
7/8”
3.09
3.15
SCEA – LAN
T - 2A
1.38
1 1/8”
3.47
3.53
45/50
60 GPM
SCGA – LAN
T - 17A
1.81
1 1/4”
3.94
4.00
150/160
120 GPM
SCIA – LAN
T - 19A
2.50
1 5/8”
4.72
4.92
350/375
Full Adjustment 4 Turns
+
-
Nominal
Capacity
c
Cavity
Cartridge Dimensions
c
b
L
30 GPM
OPTION ORDERING INFORMATION
b
Typical
Cartridge
Model Code
SC ✱ A – ✱ ✱ ✱
Control**
Adjustment Range
Seal
C 15 GPM
L Standard Screw
A 500 - 3000 psi
N Buna-N
E 30 GPM
C Tamper Resistant
W 800 - 4500 psi
V Viton
G 60 GPM
B 300 - 1500 psi
I
D 200 - 800 psi
120 GPM
C 2000 - 6000 psi
3
Drain
2
Sequence
Inlet 1
Locating
Shoulder
a
** See page 244 for information
on Control Options
28
Adjustment Range Options:
A, B and W are standard set at 1000 psi.
C Option is standard set at 2000 psi.
D Option is standard set at 400 psi.
Customer may specify pressure setting.
US Selected Assemblies Catalogue #999-901-192
TECHNICAL TIPS / PERFORMANCE CURVES
Performance Curves
Pressure Drop-full Sequence
Reverse Free Flow
SCCA-L*N
300
P = psi
P = psi
300
200
100
0
3
6
9
12
Flow = GPM
200
100
15
0
3
0
6
6
9
12
15
12
18
24
30
24
36
48
60
48
72
96 120
Flow = GPM
SCEA-L*N
300
P = psi
300
P = psi
Applications
SC*A series of sequence valves have an integral
reverse free flow check and may be used in a similar
manner to the cartridges without the check.
Design Concepts and Features
■
This is a zero pilot flow valve. Port 3 must not be
plugged.
■
Pressure at Port 3 is directly additive to valve
setting.
■ Typical response time is 2 ms.
■ Maximum leakage is 10 drops/min. at reseat.
■
Reseat exceeds 85% of set pressure.
■
Reverse free flow check cracking pressure is 20 psi
to 45 psi, depending on frame size.
SEQUENCE
Sequence Valves, Reverse Free Flow Check
200
100
0
6
12
18
24
Flow = GPM
200
100
30
Flow = GPM
SCGA-L*N
300
P = psi
P = psi
300
200
100
0
12
24
36
48
Flow = GPM
200
100
0
60
12
Flow = GPM
SCIA-L*N
300
P = psi
P = psi
300
200
100
0
24
48
72
Flow = GPM
96 120
200
100
0
General Application Requirements
■
■
■
■
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at a 4 GPM flow rate.
US Selected Assemblies Catalogue #999-901-192
29
24
Flow = GPM
SEQUENCE
Line Mounted Assemblies
THREE PORT PRESSURE SEQUENCING APPLICATIONS
(90 DEGREE BODIES)
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
3
0-15 GPM
Cavity T-11A
2
1.25
.62
1
0
Mounting Holes:
.34 diameter through hole
2 places.
0
.38
L Control
2.40 Max.
2
1
1.25
3
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
SCCA-LAN-ECB
1/2” NPTF
1/4” NPTF
SCCA-LAN-ECC
SAE-4
SAE-4
SCCA-LAN-ECH
SAE-6
SAE-6
SCCA-LAN-ECI
SAE-8
SAE-6
SCCA-LAN-ECJ
2.50
1.56
0
3
2
2.53 3.00
0-30 GPM
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
Cavity T-2A
1.50
.75
1
0
0
Mounting Holes:
.42 diameter through hole
2 places.
L Control
2.66 Max.
2
.50
1
1.62
3
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
SCEA-LAN-BCB
1/2” NPTF
1/4” NPTF
SCEA-LAN-BCC
3/4” NPTF
1/4” NPTF
SCEA-LAN-BCD
SAE-6
SAE-6
SCEA-LAN-BCH
SAE-8
SAE-6
SCEA-LAN-BCI
3.00
0
1.72
2.66 3.25
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 28 for cartridge model SC*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
30
US Selected Assemblies Catalogue #999-901-192
THREE PORT PRESSURE SEQUENCING APPLICATIONS
(90 DEGREE BODIES)
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
3
0-60 GPM
Cavity T-17A
2.25
2
2.12
0
1
Mounting Holes:
.42 diameter through hole
2 places.
0
2
.75
Ports
1 and 2
L Control
2.82 Max.
1
2.00
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
SCGA-LAN-HCE
1 1/4” NPTF
1/4” NPTF
SCGA-LAN-HCF
SAE-12
SAE-6
SCGA-LAN-HCL
SAE-16
SAE-6
SCGA-LAN-HCM
3
4.00
2.12
0
3
0-120 GPM
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
3.50 4.25
Cavity T-19A
3.00
2
1.50
1
0
0
.50
Mounting Holes:
.42 diameter through hole
2 places.
Ports
1 and 2
L Control
3.56 Max.
2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
SCIA-LAN-KCE
1 1/4” NPTF
1/4” NPTF
SCIA-LAN-KCF
1
2.25
3
4.00
0
2.47
4.25 5.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 28 for cartridge model SC*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
31
SEQUENCE
Line Mounted Assemblies
SEQUENCE
NOTES
32
US Selected Assemblies Catalogue #999-901-192
Pressure Reducing Assemblies
Cartridge Type
Page
3
2
Pilot Operated
34
1
Line Mounted Assemblies
(Body Type)
3
2
90 Degree
36
90 Degree 1.50” SAE C61/C62 Flange Port
38
90 Degree with Reverse Free Flow Check
39
G
1
3
2
G
1
3
2
1
G
US Selected Assemblies Catalogue #999-901-192
33
PRESSURE REDUCING
Pressure Reducing Valves
PILOT OPERATED REDUCING
3
2
1
5 GPM
PBBB – LAN
T - 163A
1.22
3/4”
2.55
2.63
2.77
10 GPM
PBDB – LAN
T - 11A
1.38
7/8”
2.50
2.56
2.75
30/35
20 GPM
PBFB – LAN
T - 2A
1.38
1 1/8”
2.81
2.88
3.06
45/50
40 GPM
PBHB – LAN
T - 17A
1.81
1 1/4”
3.28
3.31
3.53
150/160
80 GPM
PBJB – LAN
T - 19A
2.50
1 5/8”
3.94
4.09
4.19
350/375
OPTION ORDERING INFORMATION
Full Adjustment 5 Turns
+
-
Nominal
Capacity
b
c
3
Drain
2
Inlet
Locating
Shoulder
Cavity
a
K
PB ✱ B – ✱ ✱ ✱
Control**
Adjustment Range
Seal
B 5 GPM*
L Standard Screw
A 100 - 3000 psi
N Buna-N
D 10 GPM
C Tamper Resistant
W 150 - 4500 psi
V Viton
F 20 GPM
K Handknob
B 50 - 1500 psi
H 40 GPM
N 60 - 800 psi
J 80 GPM
Q 60 - 400 psi
a
1
Reduced Pressure
Cartridge Dimensions
c
b
L
C
Installation
Torque
(lb. ft.)
25/30
Capacity
Typical
Cartridge
Model Code
** See page 244 for information
on Control Options
34
Adjustment Range Options:
All are standard set at 200 psi.
Maximum pressure differentials for spring ranges:
A and B are 3000 psi.
N and Q are 2000 psi.
W is 5000 psi inlet pressure.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
US Selected Assemblies Catalogue #999-901-192
PRESSURE REDUCING
TECHNICAL TIPS / PERFORMANCE CURVES
Pressure Reducing Valves, Pilot Operated
No Load Pressure Drop
with Valve Full Open
Regulated Pressure
200
2000
150
1500
P = psi
P = psi
PBBB-L*N
100
50
0
1
2
3
4
Flow = GPM
1000
500
0
5
2.50
5
7.5
5
10
15
10
20
30
Flow = GPM
200
2000
150
1500
P = psi
P = psi
PBDB-L*N
100
50
0
2
4
6
8
Flow = GPM
1000
500
0
10
Flow = GPM
PBFB-L*N
200
2000
150
1500
P = psi
Note: Sun also offers reducing/relieving cartridges (PP*B) that are
functionally interchangeable with reducing cartridges. However,
with the reducing/relieving valves it is necessary to have a full flow
capacity return passage from port 3. See page 42 for further details.
Performance Curves
P = psi
Applications
Pilot operated reducing cartridges reduce high
primary pressure at port 2 (inlet) to a controlled lower
pressure at port 1. Port 3 is the pilot drain connection
and pressure in this port is directly additive to the
reduced pressure setting.
■
Provide a controlled lower pressure to a secondary
circuit function.
■
Provide accurate reduced pressure control for
clamp and hold down circuits.
Design Concepts and Features
■ Low hysteresis for accurate pressure regulation.
■ High flow capacity relative to physical size.
■ Low pilot flow (from 7 to 20 in.3/min.) dependent
on frame size.
■
Incorporates a 150 micron screen to protect main
stage control orifice from contamination.
■
Multiple spring ranges for optimum adjustment
control.
■ See page 34 for maximum operating pressure
differentials for individual spring ranges.
100
50
0
5
10
15
Flow = GPM
1000
500
20
0
Flow = GPM
200
2000
150
1500
P = psi
P = psi
PBHB-L*N
100
50
0
10
20
30
Flow = GPM
1000
500
40
0
10
20
30
40
40
60
80
Flow = GPM
50
60
200
2000
150
1500
P = psi
P = psi
PBJB-L*N
100
50
0
20
40
60
Flow = GPM
80
1000
500
0
20
General Application Requirements
■
■
■
■
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at zero flow rate.
US Selected Assemblies Catalogue #999-901-192
35
Flow = GPM
100 120
PRESSURE REDUCING
Line Mounted Assemblies
THREE PORT PRESSURE REDUCING APPLICATIONS
(90 DEGREE BODIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
3
2
0-5 GPM
Cavity T-163A
1.00
G
.50
0
1
Mounting Holes:
.28 diameter through hole
2 places.
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
PBBB-LAN-JFB
SAE-4
SAE-4
PBBB-LAN-JFH
SAE-6
SAE-4
PBBB-LAN-JFI
0
.28
L Control
1.91 Max.
2
1
.97
3
G
2.00
1.31
.59
0
2.14 2.59
1/4 NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
3
G
.62
0
1
Mounting Holes:
.34 diameter through hole, 2 places.
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
PBDB-LAN-EFB
1/2” NPTF
1/4” NPTF
PBDB-LAN-EFC
SAE-4
SAE-4
PBDB-LAN-EFH
SAE-6
SAE-6
PBDB-LAN-EFI
SAE-8
SAE-6
PBDB-LAN-EFJ
0
1
1.25
3
G
2.50
0
3
L Control
1.81 Max.
2
.38
.81
1.56
2.53 3.00
1/4 NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-20 GPM
Cavity T-2A
1.50
2
G
.75
0
1
Ports
1 and 2
Cavity T-11A
1.25
2
Ports
1 and 2
0-10 GPM
Mounting Holes:
.42 diameter through hole, 2 places.
Port 3
Assembly
Model Code*
1/2” NPTF
1/4” NPTF
PBFB-LAN-BFC
3/4” NPTF
1/4” NPTF
PBFB-LAN-BFD
SAE-10
SAE-6
PBFB-LAN-BFK
SAE-12
SAE-6
PBFB-LAN-BFL
0
L Control
2.00 Max.
2
.50
1
1.62
3
G
3.00
0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
.75
1.72
2.66 3.25
1/4 NPTF Gauge Port
NOTES: Page 34 for cartridge model PB*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
36
US Selected Assemblies Catalogue #999-901-192
THREE PORT PRESSURE REDUCING APPLICATIONS
(90 DEGREE BODIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-40 GPM
Cavity T-17A
3
2
2.25
G
1
1.12
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
PBHB-LAN-HFE
1 1/4” NPTF
1/4” NPTF
PBHB-LAN-HFF
SAE-12
SAE-6
PBHB-LAN-HFL
SAE-16
SAE-6
PBHB-LAN-HFM
1/4 NPTF Gauge Port
Mounting Holes:
.42 diameter through hole, 2 places.
0
L Control
2.15 Max.
2
.75
1
2.00
3
G
4.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
1.03
0
2.12
3.44 4.25
0-80 GPM
Cavity T-19A
3
3.00
2
G
1.50
1
0
1/4 NPTF Gauge Port
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
PBJB-LAN-KFE
1 1/4” NPTF
1/4” NPTF
PBJB-LAN-KFF
Mounting Holes:
.42 diameter through hole. 2 places.
0
.50
L Control
2.78 Max.
2
1
2.25
3
G
4.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0
1.00
2.47
4.25 5.00
NOTES: Page 34 for cartridge model PB*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
37
PRESSURE REDUCING
Line Mounted Assemblies
PRESSURE REDUCING
Line Mounted Assemblies
THREE PORT PRESSURE REDUCING APPLICATIONS
(90 DEGREE, 1.50” SAE C61/C62 FLANGE PORT BODIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-80 GPM
Cavity T-19A
3
4.00
2
G
2.00
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1 1/2” SAE C61
SAE-6
PBJB-LAN-KFR
1/4 NPTF Gauge Port
Mounting Holes: (opposite side)
.375-16 UNC-2B x .62 deep, 2 places.
0
.47
L Control
2.78 Max.
2
1.97
3.47
3.94
1
0 .75
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
3
G
2.19
0-80 GPM
3
4.50
G
2.25
4.00 4.75
Cavity T-19A
2
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1 1/2” SAE C62
SAE-6
PBJB-LAN-KF6
1/4 NPTF Gauge Port
Mounting Holes: (opposite side)
.375-16 UNC-2B x .62 deep, 2 places
0
.47
2.78
Max.
2
2.47
4.47
4.94
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
1
G
0 .75
L Control
3
2.41
4.19 4.94
NOTES: Page 34 for cartridge model PB*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
38
US Selected Assemblies Catalogue #999-901-192
THREE PORT PRESSURE REDUCING APPLICATIONS
(BODIES WITH REVERSE FREE FLOW CHECK)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-5 GPM
Cavity T-163A
3
1.00
1
2
G
0
Mounting Holes:
.28 diameter through hole, 2 places.
1.50
Ports
1 and 2
Port 3
Assembly
Model Code*
1/4” NPTF
1/4” NPTF
PBBB-LAN-J2A
3/8” NPTF
1/4” NPTF
PBBB-LAN-J2B
SAE-4
SAE-4
PBBB-LAN-J2H
SAE-6
SAE-4
PBBB-LAN-J2I
0
.25
L Control
1.92 Max.
3
1
CXBA-XCN
.75
G
2
.70
1.73
2.75
3.00
0
2.56 3.00
1/4 NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-10 GPM
Cavity T-11A
3
1.25
1
2
G
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
PBDB-LAN-E6B
1/2” NPTF
1/4” NPTF
PBDB-LAN-E6C
SAE-6
SAE-4
PBDB-LAN-E6I
SAE-8
SAE-6
PBDB-LAN-E6J
0
CXCD-XCN
1/4 NPTF Gauge Port
Mounting Holes:
.34 diameter through hole, 2 places.
0
L Control
1.69 Max.
3
1
1.00
1.50
G
2.00
2
.59
3.00
.91
0
3.03 3.62
3.31
2.06
1/4 NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-20 GPM
Cavity T-2A
3
1
2
1.50
G
0
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
PBFB-LAN-B6B
1/2” NPTF
1/4” NPTF
PBFB-LAN-B6C
3/4” NPTF
1/4” NPTF
PBFB-LAN-B6D
SAE-6
SAE-6
PBFB-LAN-B6I
SAE-8
SAE-6
PBFB-LAN-B6J
0
Ports
1 and 2
Mounting Holes:
.42 diameter through hole. 2 places
3
1
L Control
1.93 Max.
1.25
.66
G
2.37
2
CXED-XCN
0
1.06
3.62
2.44
1/4 NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 34 for cartridge model PB*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
US Selected Assemblies Catalogue #999-901-192
39
PRESSURE REDUCING
Line Mounted Assemblies
PRESSURE REDUCING
Line Mounted Assemblies
THREE PORT PRESSURE REDUCING APPLICATIONS
(BODIES WITH REVERSE FREE FLOW CHECK)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-40 GPM
3
Cavity T-17A
CXGD-XCN
0
1
2
G
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
PBHB-LAN-H2*
1 1/4” NPTF
1/4” NPTF
PBHB-LAN-H2*
SAE-12
SAE-6
PBHB-LAN-H2*
SAE-16
SAE-6
PBHB-LAN-H2*
2.50
Mounting Holes:
.42 diameter through hole, 2 places.
1.44
5.00
3
1
3.50
3.12
.91
L Control
1.87 Max.
G
1.50
2
0
3.44 4.75 5.50
0 .38 2.00
1/4 NPTF Gauge Port
5.12
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-80 GPM
3
Cavity T-19A
CXID-XCN
0
1
2
G
3.00
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
PBJB-LAN-KK2*
1 1/4” NPTF
1/4” NPTF
PBJB-LAN-KK2*
Mounting Holes:
.42 diameter through hole, 2 places.
6.00
1
3
4.00
1.13
2.72
Max.
G
L Control
1.50
2
0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0 .50
1.88
4.41 6.22 7.00
1/4 NPTF Gauge Port
6.50
NOTES: Page 34 for cartridge model PB*B shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
40
US Selected Assemblies Catalogue #999-901-192
Reducing/Relieving Assemblies
Cartridge Type
Page
3
2
Pilot Operated
42
Direct Acting
42
1
3
2
1
Line Mounted Assemblies
(Body Type)
3
2
G
90 Degree, High Capacity Port 3
90 Degree, 1.50 SAE C61/C62 Flange Port, High Capacity Port 3
44
46
90 Degree with Reverse Free Flow Check
90 Degree with Reverse Free Flow Check, High Capacity Port 3
47
48
1
3
2
G
1
US Selected Assemblies Catalogue #999-901-192
41
REDUCING/RELIEVING
Reducing/Relieving Valves
PILOT OPERATED REDUCING/RELIEVING
3
Capacity
2
1
Typical
Cartridge
Model Code
PPDB – LAN
T - 11A
1.38
7/8”
2.50
2.56
T - 2A
1.38
1 1/8”
2.81
2.88
3.06
45/50
40 GPM
PPHB – LAN
T - 17A
1.81
1 1/4”
3.28
3.31
3.53
150/160
80 GPM
PPJB – LAN
T - 19A
2.50
1 5/8”
3.94
4.09
4.19
350/375
2.75
PP ✱ B – ✱ ✱ ✱
Base
Price
Control**
Adjustment Range
Seal
D 10 GPM
L Standard Screw
A 100 - 3000 psi
N Buna-N
F 20 GPM
C Tamper Resistant
W 150 - 4500 psi
V Viton
H 40 GPM
K Handknob
B 50 -1500 psi
J 80 GPM
2
Inlet
Installation
Torque
(lb. ft.)
30/35
PPFB – LAN
Nominal
Capacity
3
Tank
K
10 GPM
Full Adjustment 5 Turns
+
-
c
a
20 GPM
OPTION ORDERING INFORMATION
b
Cavity
Cartridge Dimensions
c
b
L
C
N 60 - 800 psi
Q 60 - 400 psi
Locating
Shoulder
a
1
Reduced Pressure
** See page 244 for information
on Control Options
Adjustment Range Options:
All are standard set at 200 psi.
Maximum pressure differentials for spring ranges:
A and B are 3000 psi.
N and Q are 2000 psi.
W is 5000 psi inlet pressure.
Customer may specify pressure setting.
DIRECT ACTING REDUCING/RELIEVING
3
Capacity
2
1
Typical
Cartridge
Model Code
Cavity
a
Cartridge Dimensions
c
b
L
C
K
Installation
Torque
(lb. ft.)
30/35
10 GPM
PRDB – LAN
T - 11A
1.38
7/8”
3.09
3.16
3.34
20 GPM
PRFB – LAN
T - 2A
1.38
1 1/8”
3.47
3.53
3.75
45/50
40 GPM
PRHB – LAN
T - 17A
1.81
1 1/4”
3.94
4.00
4.19
150/160
80 GPM
PRJB – LAN
T - 19A
2.50
1 5/8”
4.87
5.03
5.13
350/375
OPTION ORDERING INFORMATION
PR ✱ B – ✱ ✱ ✱
Full Adjustment 5 Turns
+
-
Nominal
3
Capacity
b
c
3
Tank
2
Inlet
D
F
H
J
Locating
Shoulder
a
1
Reduced Pressure
10 GPM
20 GPM
40 GPM
80 GPM
Base
Price
Control**
L Standard Screw
C Tamper Resistant
K Handknob
Adjustment Range Options:
PRDB Only:
A, W are standard set at 1000 psi.
B, D, E, S are standard set at 200 psi.
PRFB, PRHB, PRJB:
A, W are standard set at 1000 psi.
B is standard set at 500 psi.
** See page 244
D is standard set at 400 psi.
for information on E is standard set at 200 psi.
Control Options
S is standard set at 100 psi.
42
A
W
B
D
E
S
Adjustment Range
Seal
Available for PRDB only
500 - 3000 psi
N Buna-N
750 - 4500 psi
V Viton
50 - 1500 psi
20 - 800 psi
20 - 400 psi
20 - 200 psi
Available for PRFB, PRHB, PRJB
A 750 - 3000 psi
W 1000 - 4500 psi
B 300 - 1500 psi
D 200 - 800 psi
E 100 - 400 psi
S 50 - 200 psi
Maximum Inlet Pressure: 5000 psi
Customer may specify pressure setting.
US Selected Assemblies Catalogue #999-901-192
REDUCING/RELIEVING
TECHNICAL TIPS / PERFORMANCE CURVES
Reducing/Relieving Valves, Pilot Operated
Regulated Pressure
PPDB-L*N
Relieving
Reducing
1500
P = psi
P = psi
Reducing
2000
2000
1000
500
1500
1000
500
0
0
-10
-5
0
5
10
Flow = GPM
-20
15
PPHB-L*N
-10
0
10
20
Flow = GPM
30
PPJB-L*N
Relieving
Reducing
Relieving
2000
Reducing
2000
1500
1000
500
0
1500
1000
500
0
-40
-20
No Load Pressure Drop PP*B-LAN
D F
H
J
200
P = psi
PPFB-L*N
Relieving
P = psi
Note: Maximum pressure differentials, inlet to outlet, see
adjustment ranges on page 42.
Note: Reducing/relieving valves require a body with a high capacity
third port.
Performance Curves
P = psi
Applications
Pilot operated reducing/relieving cartridges may be
used interchangeably with reducing valve, however,
they have one additional function; they will maintain a
constant pressure at port 1 during reverse flow
conditions to port three.
Design Concepts and Features
■
Low hysteresis for accurate pressure regulation.
■
Minimal dead-band provides low transition
pressure between reducing and relieving modes.
■ Low pilot control flow, 7 to 20 in. 3/min. dependent
on frame size.
■
Pressure at port 3 is directly additive to valve
setting and should not exceed 3000 psi.
0
20
Flow = GPM
40
-80
60
-40
0
40
80
Flow = GPM
120
150
100
50
0
20
40
60
Flow = GPM
80
Reducing/Relieving Valves, Direct Acting
Regulated Pressure
PRDB-L*N
PRFB-L*N
Relieving
Relieving
Reducing
P = psi
P = psi
1500
1000
2000
1000
500
0
0
-5
-2.5
0
5
Flow = GPM
10
-40
15
PRHB-L*N
-20
Reducing
■
■
2000
1000
0
43
15 20 25
Reducing
3000
2000
1000
0
-30
0
10 20
Flow = GPM
30 40 50
-60
-40
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at zero flow rate.
US Selected Assemblies Catalogue #999-901-192
5 10
Relieving
3000
General Application Requirements
■
0
Flow = GPM
PRJB-L*N
Relieving
-60
■
Reducing
3000
2000
P = psi
Note: Maximum pressure differentials, inlet to outlet, see
adjustment ranges on page 42.
Performance Curves
P = psi
Applications
Direct acting reducing/relieving cartridges may be
used interchangeably with pilot operated units. These
valves offer low internal leakage and increased
reliability in contaminated systems, this makes them
ideal choices in accumulator and brake circuits. They
exhibit lower overshoot characteristics than pilot
operated valves and should therefore be considered in
clamping circuits.
Design Concepts and Features
■ Damped differential construction for stable
operation.
■
Low internal leakage in both no flow and control
flow modes; less than 2 in3/min.
■
Multiple spring ranges for optimum control
-20
0
20 40 60 80
Flow = GPM
REDUCING/RELIEVING
Line Mounted Assemblies
THREE PORT PRESSURE REDUCING/RELIEVING APPLICATIONS
(90 DEGREE, HIGH CAPACITY PORT 3 BODIES)
PILOT OPERATED
ASSEMBLIES
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-10 GPM
Cavity T-11A
3
1.25
2
.62
G
0
1
Mounting Holes:
.34 diameter through hole, 2 places.
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
3/8” NPTF
PPDB-LAN-ELB
1/2” NPTF
3/8” NPTF
PPDB-LAN-ELC
SAE-6
SAE-6
PPDB-LAN-ELI
SAE-8
SAE-8
PPDB-LAN-ELJ
SAE-10
SAE-8
PPDB-LAN-ELK
0
L Control
2.40 Max.
2
.38
1
1.25
3
G
2.50
.75
0
1.56
2.44 3.00
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
3/8” NPTF
PRDB-LAN-ELB
1/2” NPTF
3/8” NPTF
PRDB-LAN-ELC
SAE-6
SAE-6
PRDB-LAN-ELI
SAE-8
SAE-8
PRDB-LAN-ELJ
SAE-10
SAE-8
PRDB-LAN-ELK
1/4 NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-20 GPM
Cavity T-2A
3
1.50
2
.75
G
0
1
Ports
1 and 2
Port 3
Assembly
Model Code*
1/2” NPTF
1/2” NPTF
PPFB-LAN-BLC
3/4” NPTF
1/2” NPTF
PPFB-LAN-BLD
SAE-6
SAE-6
SAE-8
SAE-10
Mounting Holes:
.42 diameter through hole
2 places.
Ports
1 and 2
Port 3
Assembly
Model Code*
1/2” NPTF
1/2” NPTF
PRFB-LAN-BLC
3/4” NPTF
1/2” NPTF
PRFB-LAN-BLD
PPFB-LAN-BLI
SAE-6
SAE-6
PRFB-LAN-BLI
SAE-8
PPFB-LAN-BLJ
SAE-8
SAE-8
PRFB-LAN-BLJ
SAE-10
PPFB-LAN-BLK
SAE-10
SAE-10
PRFB-LAN-BLK
0
1
1.62
3
G
3.00
0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
L Control
2.66 Max.
2
.50
.91
1.72
2.66 3.25
1/4 NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 42 for cartridge models PP*B-*** and PR*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
44
US Selected Assemblies Catalogue #999-901-192
THREE PORT PRESSURE REDUCING/RELIEVING APPLICATIONS
(90 DEGREE, HIGH CAPACITY PORT 3 BODIES)
PILOT OPERATED
ASSEMBLIES
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-40 GPM
Cavity T-17A
3
2.25
2
G
1
Ports
1 and 2
Assembly
Model Code*
Port 3
1” NPTF
3/4” NPTF
PPHB-LAN-HEE
1 1/4” NPTF
3/4” NPTF
PPHB-LAN-HEF
SAE-12
SAE-12
PPHB-LAN-HEL
SAE-16
SAE-12
PPHB-LAN-HEM
1.12
0
Mounting Holes:
.42 diameter through hole, 2 places.
0
L Control
2.82 Max.
2
.75
1
2.00
G
Ports
1 and 2
Port 3
Assembly
Model Code*
PRHB-LAN-HEE
1” NPTF
3/4” NPTF
1 1/4” NPTF
3/4” NPTF
PRHB-LAN-HEF
SAE-12
SAE-12
PRHB-LAN-HEL
SAE-16
SAE-12
PRHB-LAN-HEM
3
4.00
1.19 2.12
3.44 4.25
1/4 NPTF Gauge Port
0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-80 GPM
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
Cavity T-19A
3
3.00
2
G
1
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1” NPTF
PPJB-LAN-KEE
1 1/4” NPTF
1” NPTF
PPJB-LAN-KEF
SAE-16
SAE-16
PPJB-LAN-KEM
SAE-20
SAE-16
PPJB-LAN-KEN
1.50
0
Mounting Holes:
.42 diameter through hole, 2 places.
0
.50
L Control
2
3.49
Max.
1
2.50
G
Ports
1 and 2
Port 3
Assembly
Model Code*
PRJB-LAN-KEE
1” NPTF
1” NPTF
1 1/4” NPTF
1” NPTF
PRJB-LAN-KEF
SAE-16
SAE-16
PRJB-LAN-KEM
SAE-20
SAE-16
PRJB-LAN-KEN
3
5.00
0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
1.06
2.50
4.31 5.25
1/4 NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 42 for cartridge models PP*B-*** and PR*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
45
REDUCING/RELIEVING
Line Mounted Assemblies
REDUCING/RELIEVING
Line Mounted Assemblies
THREE PORT PRESSURE REDUCING/RELIEVING APPLICATIONS
(90 DEGREE, 1.50” SAE C61/C62 FLANGE PORT BODIES, HIGH CAPACITY PORT 3)
PILOT OPERATED
ASSEMBLIES
0-80 GPM
3
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
Cavity T-19A
4.00
2
G
2.00
1
0
Ports
1, 2, and 3
Assembly
Model Code*
1 1/2” SAE C61
PPJB-LAN-KER
1/4 NPTF Gauge Port
Mounting Holes: (opposite side)
.375-16 UNC-2B x .62 deep. 2 places.
0
.47
Ports
1, 2, and 3
1 1/2” SAE C61
Assembly
Model Code*
PRJB-LAN-KER
L Control
2.81 Max.
2
1.97
1
G
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3
3.94
0 .75
2.19
4.00
0-80 GPM
3
4.50
G
2.25
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
5.62
Cavity T-19A
2
1
Ports
1, 2, and 3
Assembly
Model Code*
1 1/2” SAE C62
PPJB-LAN-KE6
Ports
1, 2, and 3
Assembly
Model Code*
1 1/2” SAE C62
PRJB-LAN-KE6
0
1/4 NPTF Gauge Port
Mounting Holes: (oppostie side)
.375-16 UNC-2B x .62 deep. 2 places.
0
.47
L Control
2
1.97
1
G
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3
3.94
0 .75
2.44
2.56
Max.
4.25
6.13
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 42 for cartridge models PP*B-*** and PR*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
46
US Selected Assemblies Catalogue #999-901-192
THREE PORT PRESSURE REDUCING/RELIEVING APPLICATIONS
(BODIES WITH REVERSE FREE FLOW CHECK)
PILOT OPERATED
ASSEMBLIES
3
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-10 GPM
Cavity T-11A
1.25
2
G
0
CXCD-XCN
1
Mounting Holes:
.34 diameter through hole, 2 places.
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
3/8” NPTF
PPDB-LAN-E4B
1/2” NPTF
3/8” NPTF
PPDB-LAN-E4C
SAE-6
SAE-6
PPDB-LAN-E4I
SAE-8
SAE-8
PPDB-LAN-E4J
SAE-10
SAE-8
PPDB-LAN-E4K
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1.00
3/8” NPTF
3/8” NPTF
PRDB-LAN-E4B
1.50
1/2” NPTF
3/8” NPTF
PRDB-LAN-E4C
SAE-6
SAE-6
PRDB-LAN-E4I
SAE-8
SAE-8
PRDB-LAN-E4J
SAE-10
SAE-8
PRDB-LAN-E4K
1
L Control
2.37 Max.
3
G
2
.59
3.00 0
.91
2.06
3.03 3.62
1/4 NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
3
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-20 GPM
Cavity T-2A
1.50
2
G
0
CXED-XCN
1
Mounting Holes:
.42 diameter through hole, 2 places.
Ports
1 and 2
Port 3
Assembly
Model Code*
1/2” NPTF
1/2” NPTF
PPFB-LAN-B4C
3/4” NPTF
1/2” NPTF
PPFB-LAN-B4D
SAE-8
SAE-8
PPFB-LAN-B4J
SAE-10
SAE-10
PPFB-LAN-B4K
0
3
1
1.25
1.50
G
2
.59
3.62 0 .38 1.06
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
2.44
L Control
2.58 Max.
Ports
1 and 2
Port 3
Assembly
Model Code*
1/2” NPTF
1/2” NPTF
PRFB-LAN-B4C
3/4” NPTF
1/2” NPTF
PRFB-LAN-B4D
SAE-8
SAE-8
PRFB-LAN-B4J
SAE-10
SAE-10
PRFB-LAN-B4K
3.34 4.00
1/4 NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 42 for cartridge models PP*B-*** and PR*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
US Selected Assemblies Catalogue #999-901-192
47
REDUCING/RELIEVING
Line Mounted Assemblies
REDUCING/RELIEVING
Line Mounted Assemblies
THREE PORT PRESSURE REDUCING/RELIEVING APPLICATIONS
(BODIES WITH REVERSE FREE FLOW CHECK, HIGH CAPACITY PORT 3)
PILOT OPERATED
ASSEMBLIES
3
DIRECT ACTING
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-40 GPM
Cavity T-17A
2.50
2
G
0
CXGD-XCN
1
Ports
1 and 2
Mounting Holes:
.42 diameter through hole, 2 places.
Assembly
Model Code*
Port 3
1” NPTF
3/4” NPTF
PPHB-LAN-H4E
1 1/4” NPTF
3/4” NPTF
PPHB-LAN-H4F
SAE-12
SAE-12
PPHB-LAN-H4L
SAE-16
SAE-12
PPHB-LAN-H4M
2.00
0
1
1.50
1.88
.91
2.88
Max.
3
G
L Control
2
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
3/4” NPTF
PRHB-LAN-H4E
1 1/4” NPTF
3/4” NPTF
PRHB-LAN-H4F
SAE-12
SAE-12
PRHB-LAN-H4L
SAE-16
SAE-12
PRHB-LAN-H4M
5.00
1.44
0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
3.44
4.75 5.50
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
1/4 NPTF Gauge Port
0-80 GPM
Cavity T-19A
3
3.00
2
G
0
CXID-XCN
1
Ports
1 and 2
Mounting Holes:
.42 diameter through hole, 2 places.
Port 3
Assembly
Model Code*
1” NPTF
3/4” NPTF
PPJB-LAN-K4E
1 1/4” NPTF
3/4” NPTF
PPJB-LAN-K4F
6.00
3
1
3.94
1.13
L Control
G
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
3/4” NPTF
PRJB-LAN-K4E
1 1/4” NPTF
3/4” NPTF
PRJB-LAN-K4F
3.65
Max.
2
0
0 .50
1.88
4.41
6.22 7.00
1/4 NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 42 for cartridge models PP*B-*** and PR*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
48
US Selected Assemblies Catalogue #999-901-192
Three Port Counterbalance Assemblies
Cartridge Type
3
2
Standard, 4000 psi Maximum Setting
Standard, 5000 psi Maximum Setting
Page
50
50
1
Line Mounted Assemblies
(Body Type)
3
2
90 Degree
52
90 Degree 2.00” C61/C62 Flange Port, 2 Cavities
54
Inline
55
90 Degree with Shuttle
56
90 Degree 1.50” C61/C62 SAE Flange Port with Shuttle, 2 Cavities
57
90 Degree Cross-Piloted, 2 Cavities
90 Degree Cross-Piloted, 1.50” SAE C61/C62 Flange Port, 2 Cavities
Inline/Inline Cross-Piloted, 1.50” SAE C61 Flange Port, 2 Cavities
58
59
60
90 Degree Cross-Piloted with Shuttle, 2 Cavities
Cross-Piloted, 1.50” SAE C61/C62 Flange Port with Shuttle, 2 Cavities
61
62
Inline Cross-Piloted with Shuttle, 2 Cavities
63
Direct Mount .75”/1.00”/1.25” SAE C61 Flange Port, Through Pilot
64
Gasket Mount
66
Gasket Mount, 2 Cavities
67
1
2
3
1
3
2
1
2
S
3
1
2
S
3
1
V1
V2
C1
C2
V1 S
V2
C1
C2
V1 S
V2
C2
C1
2
3
3
1
V2
V1
C1
C2
V2
V1
C1
C2
US Selected Assemblies Catalogue #999-901-192
49
THREE PORT
COUNTERBALANCE
Counterbalance Valves
STANDARD, 4000 PSI MAXIMUM SETTING
3
2
1
Cartridge Dimensions
c
b
L
Capacity
Typical
Cartridge
Model Code
Cavity
a
15 GPM
CBCA – LHN
T - 11A
1.38
30 GPM
CBEA – LHN
T - 2A
1.38
1 1/8”
2.38
2.50
45/50
60 GPM
CBGA – LHN
T - 17A
1.81
1 1/4”
2.75
3.31
150/160
120 GPM
CBIA – LHN
T - 19A
2.50
1 5/8”
3.50
4.09
350/375
7/8”
1.97
C
2.19
Installation
Torque
(lb. ft.)
30/35
OPTION ORDERING INFORMATION
CB ✱ ✱ – ✱ ✱ ✱
Turn screw clockwise to reduce
setting and release load.
Complete Adjustment 3 Turns
+
-
b
Nominal
Capacity
c
C 15 GPM
L Standard Screw
E 30 GPM
C Tamper Resistant
Seal
N Buna-N
30 psi Check Spring
H 1000 - 4000 psi
I
V Viton
400 - 1500 psi
Version
120 GPM
Locating
Shoulder
A 3:1 Pilot Ratio
5 psi Check Spring
B 1.5:1 Pilot Ratio
(with sealed pilot)
A 1000 - 4000 psi
B 400 - 1500 psi
Y 2:1 Pilot Ratio
(with bleed through pilot)
a
2
Valve
Cracking Pressure
G 60 GPM
I
3
Pilot
Control**
Adjustment Range Options:
A and H are standard set at 3000 psi.
I and B are standard set at 1000 psi.
Customer may specify setting.
** See page 244 for information
on Control Options
Load 1
STANDARD, 5000 PSI MAXIMUM SETTING
2
Cavity
a
15 GPM
CBCG – LJN
T - 11A
1.38
7/8”
1.97
2.19
Installation
Torque
(lb. ft.)
30/35
30 GPM
CBEG – LJN
T - 2A
1.38
1 1/8”
2.38
2.50
45/50
Capacity
3
1
Cartridge Dimensions
c
b
L
Typical
Cartridge
Model Code
C
60 GPM
CBGG – LJN
T - 17A
1.81
1 1/4”
2.75
3.31
150/160
120 GPM
CBIG – LJN
T - 19A
2.50
1 5/8”
3.50
4.09
350/375
OPTION ORDERING INFORMATION
CB ✱ ✱ – ✱ ✱ ✱
Turn screw clockwise to reduce
setting and release load.
Complete Adjustment 3 Turns
+
b
c
Nominal
Capacity
C 15 GPM
L Standard Screw
E 30 GPM
C Tamper Resistant
G 60 GPM
I
3
Pilot
Locating
Shoulder
2
Valve
Load 1
a
Control**
Cracking Pressure
30 psi Check Spring
J 2000 - 5000 psi
Seal
N Buna-N
V Viton
K 1000 - 2500 psi
Version
120 GPM
G 4.5:1 Pilot Ratio
5 psi Check Spring
H 10:1 Pilot Ratio
C 2000 - 5000 psi
L 2.3:1 Pilot Ratio
(with sealed pilot)
D 1000 - 2500 psi
** See page 244 for information
on Control Options
50
Adjustment Range Options:
J and C are standard set at 3000 psi.
K and D are standard set at 2000 psi.
Customer may specify setting.
US Selected Assemblies Catalogue #999-901-192
THREE PORT
COUNTERBALANCE
TECHNICAL TIPS / PERFORMANCE CURVES
Counterbalance Valves, 3:1, 1.5:1 and 2:1 Pilot Ratio, External Pilot, Non-vented
Performance Curves
Free Flow and Pilot Open Pressure Drop
CBE*-L*N
400
400
300
300
P = psi
P = psi
CBC*-L*N
200
100
0
200
100
0
0
5
10
15
0
10
Q = GPM
20
30
80
120
Q = GPM
CBG*-L*N
CBI*-L*N
400
400
300
300
P = psi
P = psi
Applications
The Sun three port counterbalance cartridges (with
pilot to open assist) are modulating devices that allow
free flow from port 2 (inlet) to port 1 (load) and then
block reverse flow until a pilot pressure inversely
proportional to the load pressure is sensed at port 3
(pilot) or load pressure exceeds relief setting. These
valves improve the motion control of most control
valve systems by ensuring that the actuator always
sees a positive load pressure, even under overrunning
load situations.
Design Concepts and Features
■
Recommended minimum setting should be 1.3
times maximum load induced pressure.
■
3:1, 1.5:1, 2:1 pilot ratio, load holding to 3000 psi
(with 4000 psi setting).
■ Load reactive pilot assist for overcenter load
control applications.
■
5 drops/min. maximum leakage at reseat.
■
Reseat exceeds 85% of set pressure at standard
setting.
■
Back pressure at Port 2 may adversely affect
operation of valve. For circuits with back pressure
Sun recommends vented counterbalance valves
CW** (vented valves).
200
100
200
100
0
0
0
20
40
0
60
40
Q = GPM
Q = GPM
Counterbalance Valves, 4.5:1, 10:1 and 2.3:1 Pilot Ratio, External Pilot, Non-vented
Performance Curves
Free Flow and Pilot Open Pressure Drop
CBE*-L*N
400
400
300
300
P = psi
P = psi
CBC*-L*N
200
100
0
200
100
0
0
5
10
15
0
Q = GPM
■
■
■
300
P = psi
400
300
200
100
80
120
100
0
0
0
20
40
60
0
Q = GPM
51
30
200
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at cracking flow 35 cc/min.
US Selected Assemblies Catalogue #999-901-192
20
CBI*-L*N
400
General Application Requirements
■
10
Q = GPM
CBG*-L*N
P = psi
Applications
The Sun three port counterbalance cartridges (with
pilot to open assist) are modulating devices that allow
free flow from port 2 (inlet) to port 1 (load) and then
block reverse flow until a pilot pressure inversely
proportional to the load pressure is sensed at port 3
(pilot) or load pressure exceeds relief setting. These
valves improve the motion control of most control
valve systems by ensuring that the actuator always sees
a positive load pressure, even under overrunning load
situations.
Design Concepts and Features
■ Recommended minimum setting should be 1.3
times maximum load induced pressure.
■
4.5:1 10:1, 2.3:1 pilot ratio, load holding to 3760
psi (with 5000 psi setting).
■
Load reactive pilot assist for overcenter load
control applications.
■ 5 drops/min. maximum leakage at reseat.
■
Reseat exceeds 85% of set pressure at standard
setting.
■
Back pressure at Port 2 may adversely affect
operation of valve. For circuits with back pressure
Sun recommends vented counterbalance valves
CW** (vented valves).
40
Q = GPM
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT LOAD CONTROL APPLICATIONS
(90 DEGREE BODIES)
PILOT RATIO
3:1, 1.5:1, 2:1
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
0-15 GPM
Cavity T-11A
3
2
1.25
.62
1
Ports
1 and 2
0
Mounting Holes:
.34 diameter through hole
2 places.
Assembly
Model Code*
Port 3
3/8” NPTF
1/4” NPTF
CBC*-LHN-ECB
1/2” NPTF
1/4” NPTF
CBC*-LHN-ECC
SAE-4
SAE-4
CBC*-LHN-ECH
SAE-6
SAE-6
CBC*-LHN-ECI
SAE-8
SAE-6
CBC*-LHN-ECJ
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
0
.38
1.28
Max.
2
1
1.25
L Control
3
2.50
1.56
0
0-30 GPM
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
CBC*-LJN-ECB
1/2” NPTF
1/4” NPTF
CBC*-LJN-ECC
SAE-4
SAE-4
CBC*-LJN-ECH
SAE-6
SAE-6
CBC*-LJN-ECI
SAE-8
SAE-6
CBC*-LJN-ECJ
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
2.53 3.00
Cavity T-2A
3
2
1.50
.75
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1/2” NPTF
1/4” NPTF
CBE*-LHN-BCC
0
3/4” NPTF
1/4” NPTF
CBE*-LHN-BCD
.50
SAE-10
SAE-6
CBE*-LHN-BCK
SAE-12
SAE-6
CBE*-LHN-BCL
Mounting Holes:
.42 diameter through hole
2 places.
1.57
Max.
2
1
1.62
3
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
1.72
Port 3
Assembly
Model Code*
1/2” NPTF
1/4” NPTF
CBE*-LJN-BCC
3/4” NPTF
1/4” NPTF
CBE*-LJN-BCD
SAE-10
SAE-6
CBE*-LJN-BCK
SAE-12
SAE-6
CBE*-LJN-BCL
L Control
3.00
0
Ports
1 and 2
2.66 3.25
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
52
US Selected Assemblies Catalogue #999-901-192
THREE PORT LOAD CONTROL APPLICATIONS
(90 DEGREE BODIES)
PILOT RATIO
3:1, 1.5:1, 2:1
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
0-60 GPM
Cavity T-17A
3
2
2.25
2.12
1
Ports
1 and 2
0
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
CBG*-LHN-HCE
0
1 1/4” NPTF
1/4” NPTF
CBG*-LHN-HCF
.75
SAE-12
SAE-6
CBG*-LHN-HCL
SAE-16
SAE-6
CBG*-LHN-HCM
Mounting Holes:
.42 diameter through hole
2 places.
2
L Control
2.61
Max.
1
2.00
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
CBG*-LJN-HCE
1 1/4” NPTF
1/4” NPTF
CBG*-LJN-HCF
SAE-12
SAE-6
CBG*-LJN-HCL
SAE-16
SAE-6
CBG*-LJN-HCM
3
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
4.00
2.12
0
0-120 GPM
3.50 4.25
Cavity T-19A
3
2
3.00
1.50
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
CBI*-LHN-KCE
1 1/4” NPTF
1/4” NPTF
CBI*-LHN-KCF
SAE-16
SAE-6
CBI*-LHN-KCM
SAE-20
SAE-6
CBI*-LHN-KCN
0
.50
Mounting Holes:
.42 diameter through hole
2 places.
2.34
Max.
2
1
2.25
Ports
1 and 2
Port 3
Assembly
Model Code*
CBI*-LJN-KCE
1” NPTF
1/4” NPTF
1 1/4” NPTF
1/4” NPTF
CBI*-LJN-KCF
SAE-16
SAE-6
CBI*-LJN-KCM
SAE-20
SAE-6
CBI*-LJN-KCN
3
L Control
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
4.00
0
2.47
4.25 5.00
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
53
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT LOAD CONTROL APPLICATIONS
(90 DEGREE 2.00” C61/C62 FLANGE PORT BODIES, 2 CAVITIES
PILOT RATIO
3:1, 1.5:1, 2:1
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
0-240 GPM
Cavity T-11A
2
3
M10 x 1.50-6H x .62 deep.
2 places.
5.94
2
1
L Control
2.34 Max.
3
1
2.97
Ports
1 and 2
Port 3
Assembly
Model Code*
2” SAE C61
SAE-6
CBI*-LHN-XZZ
0
0
1.97
0
4.25 6.03 6.75
Ports
1 and 2
Port 3
Assembly
Model Code*
2” SAE C61
SAE-4
CBI*-LJN-XZZ
0
.97
2
2.88
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
4.97
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
5.94
0-240 GPM
Cavity T-19A
2
3
5.94
1
2.97
Ports
1 and 2
Port 3
2” SAE C62
SAE-6
Assembly
Model Code*
CBI*-LHN-Z8Z
2
3
0
Mounting Holes:
.500-13 UNC-2B x .87 deep. 2 places.
L Control
0
2.34 Max.
1.06
2.97
Ports
1 and 2
Port 3
Assembly
Model Code*
2” SAE C62
SAE-6
CBI*-LJN-Z8Z
1
4.88
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
5.94
0
2.26
4.97
7.50
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
54
US Selected Assemblies Catalogue #999-901-192
THREE PORT LOAD CONTROL APPLICATIONS
(INLINE BODIES)
PILOT RATIO
3:1, 1.5:1, 2:1
0-15 GPM
Cavity T-11A
3
2
Mounting Holes:
.34 diameter through
2 places.
Counterbore for
5/16 bolt.
1
Ports
1 and 2
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
Assembly
Model Code*
Port 3
L Control
1.28 Max.
2.64
3/8” NPTF
1/4” NPTF
CBC*-LHN-EJB
SAE-6
SAE-6
CBC*-LHN-EJI
2.05
SAE-8
SAE-6
CBC*-LHN-EJJ
1.28
3
1.25
.66
2
0
1.78 1.16
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
CBC*-LJN-EJB
SAE-6
SAE-6
CBC*-LJN-EJI
SAE-8
SAE-6
CBC*-LJN-EJJ
1
0
0
0 .29
.31 0
Ports
1 and 2
1.26
3.38
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
0-30 GPM
Cavity T-2A
3
2
Mounting Holes:
.34 diameter through hole
Counterbore for hex
head bolt.
2 places.
1
Ports
1 and 2
Port 3
Assembly
Model Code*
1/2” NPTF
1/4” NPTF
CBE*-LHN-BVC
3.22
3/4” NPTF
1/4” NPTF
CBE*-LHN-BVD
2.56
L Control
1.66 Max.
SAE-6
SAE-6
CBE*-LHN-BVI
1.68
SAE-8
SAE-6
CBE*-LHN-BVJ
.88
1.66
2
0
2.12 1.34
3
1
0
.31 0
Ports
1 and 2
Port 3
Assembly
Model Code*
1/2” NPTF
1/4” NPTF
CBE*-LJN-BVC
3/4” NPTF
1/4” NPTF
CBE*-LJN-BVD
SAE-6
SAE-6
CBE*-LJN-BVI
SAE-8
SAE-6
CBE*-LJN-BVJ
0
0
1.44
3.88
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
0-60 GPM
Cavity T-17A
3
2
Mounting Holes:
.42 diameter through hole.
1.00 diameter counterbore.
2 places.
1
Ports
1 and 2
Port 3
Assembly
Model Code*
3/4” NPTF
1/4” NPTF
CBG*-LHN-HDD
1” NPTF
1/4” NPTF
CBG*-LHN-HDE
SAE-12
SAE-6
CBG*-LHN-HDL
SAE-16
SAE-6
CBG*-LHN-HDM
L Control
1.84 Max.
3.88
3.16
3
2.28
2.28
.94
0
3.00
1.69
1
2
0
.38 0
Port 3
Assembly
Model Code*
3/4” NPTF
1/4” NPTF
CBG*-LJN-HDD
1” NPTF
1/4” NPTF
CBG*-LJN-HDE
SAE-12
SAE-6
CBG*-LJN-HDL
SAE-16
SAE-6
CBG*-LJN-HDM
0
0 .38
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Ports
1 and 2
1.96
4.62
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
55
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT LOAD CONTROL APPLICATIONS
(90 DEGREE BODIES WITH SHUTTLE)
PILOT RATIO
3:1, 1.5:1, 2:1
0-15 GPM
2
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
Cavity T-11A
S
3
0
.62
1
Ports
1 and 2
Ports
Shuttle and 3
1.25
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
CBC*-LHN-EGB
1/2” NPTF
1/4” NPTF
CBC*-LHN-EGC
SAE-6
SAE-6
CBC*-LHN-EGI
SAE-8
SAE-6
CBC*-LHN-EGJ
SAE-10
SAE-6
CBC*-LHN-EGK
Mounting Holes:
.34 diameter through hole, 2 places.
3.00
2.62
1.28
Max.
2
1.75
1
L Control
Ports
1 and 2
Ports
Shuttle and 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
CBC*-LJN-EGB
1/2” NPTF
1/4” NPTF
CBC*-LJN-EGC
SAE-6
SAE-6
CBC*-LJN-EGI
SAE-8
SAE-6
CBC*-LJN-EGJ
SAE-10
SAE-6
CBC*-LJN-EGK
3
S
0
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
0
1.38
0-30 GPM
2
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
2.53 3.00
Cavity T-2A
S
3
0
.62
1
Ports
1 and 2
Ports
Shuttle and 3
1/2” NPTF
3/4” NPTF
1.25
Assembly
Model Code*
3.25
1/4” NPTF
CBE*-LHN-BGC
2.75
1/4” NPTF
CBE*-LHN-BGD
SAE-6
SAE-6
CBE*-LHN-BGI
SAE-8
SAE-6
CBE*-LHN-BGJ
Mounting Holes:
.42 diameter through hole, 2 places.
1.60
Max.
2
1
1.75
Ports
1 and 2
Ports
Shuttle and 3
Assembly
Model Code*
1/2” NPTF
1/4” NPTF
CBE*-LJN-BGC
3/4” NPTF
1/4” NPTF
CBE*-LJN-BGD
SAE-6
SAE-6
CBE*-LJN-BGI
SAE-8
SAE-6
CBE*-LJN-BGJ
L Control
3
S
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
0
0
1.56
0-60 GPM
2
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
2.69 3.25
Cavity T-17A
S
3
2.25
1.12
1
0
Ports
1 and 2
Ports
Shuttle and 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
CBG*-LHN-HDE
1 1/4” NPTF
1/4” NPTF
CBG*-LHN-HDF
SAE-12
SAE-6
CBG*-LHN-HDL
SAE-16
SAE-6
CBG*-LHN-HDM
0
Mounting Holes:
.42 diameter through hole, 2 places.
1.63
Max.
2
.75
2.00
1
Ports
1 and 2
Ports
Shuttle and 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
CBG*-LJN-HDE
1 1/4” NPTF
1/4” NPTF
CBG*-LJN-HDF
SAE-12
SAE-6
CBG*-LJN-HDL
SAE-16
SAE-6
CBG*-LJN-HDM
L Control
S
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
3
4.00
0
.75
2.25
3.44 4.25
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
56
US Selected Assemblies Catalogue #999-901-192
THREE PORT LOAD CONTROL APPLICATIONS
(90 DEGREE 1.50” SAE FLANGE PORT C61/C62 BODIES WITH SHUTTLE)
PILOT RATIO
3:1, 1.5:1, 2:1
0-240 GPM
2
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
Cavity T-19A
S
3
Port S in end of cartridge Mounting Holes:
CSAA-EXN
.375-16 UNC-2B
.72
x .63 deep. 2 places.
3.94
3.47
1
Ports
1 and 2
Ports
Shuttle and 3
SAE-4
1 1/2” SAE C61
Assembly
Model Code*
1.62
CBI*-LHN-KGR
.47
0
2.31
Max.
3
1
2
0
L Control
2.19
0
Ports
1 and 2
Ports
Shuttle and 3
1 1/2” SAE C61
SAE-4
CBI*-LJN-KGR
3.88 4.75
2.00
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
4.00
0-240 GPM
2
S
3
Cavity T-19A
Port S in end of cartridge Mounting Holes:
CSAA-EXN
.375-16 UNC-2B
x .63 deep. 2 places.
.72
3.94
3.47
3
1
1.88
Ports
1 and 2
Ports
Shuttle and 3
Assembly
Model Code*
1 1/2” SAE C62
SAE-6
CBI*-LHN-KG6
1
3
2
.47
0
1
2.33
Max.
2
L Control
0
2.44
Ports
1 and 2
Ports
Shuttle and 3
Assembly
Model Code*
1 1/2” SAE C62
SAE-6
CBI*-LJN-KG6
4.12 5.00
0
2.25
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
4.50
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
US Selected Assemblies Catalogue #999-901-192
57
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT LOAD CONTROL APPLICATIONS
(90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES)
PILOT RATIO
3:1, 1.5:1, 2:1
V1
0-15 GPM
V2
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
Cavity T-11A
1.25
.62
C1
0
C2
Mounting Holes:
.34 diameter through hole, 2 places.
Ports
C1, C2, V1 & V2
Assembly
Model Code*
3/8” NPTF
CBC*-LHN-YEB
1/2” NPTF
CBC*-LHN-YEC
SAE-6
CBC*-LHN-YEI
SAE-8
CBC*-LHN-YEJ
SAE-10
CBC*-LHN-YEK
0
.38
C1
1.25
V1
Assembly
Model Code*
3/8” NPTF
CBC*-LJN-YEB
1/2” NPTF
CBC*-LJN-YEC
C2
2.75
V2
0
.50
3.00
1.56
SAE-6
CBC*-LJN-YEI
SAE-8
CBC*-LJN-YEJ
SAE-10
CBC*-LJN-YEK
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier
/S to order Ductile Iron for pressure rating over 3000 psi.
4.00
0-30 GPM
V2
Ports
C1, C2, V1 & V2
L Control
3.62
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier
/S to order Ductile Iron for pressure rating over 3000 psi.
1.63
Max.
V1
Cavity T-2A
1.50
.75
C1
0
C2
Mounting Holes:
.42 diameter through hole, 2 places.
Ports
C1, C2, V1 & V2
Assembly
Model Code*
3/8” NPTF
CBE*-LHN-YAB
1/2” NPTF
CBE*-LHN-YAC
3/4” NPTF
CBE*-LHN-YAD
SAE-10
CBE*-LHN-YAK
SAE-12
CBE*-LHN-YAL
0
1.50
3.00
C1
Ports
C1, C2, V1 & V2
Assembly
Model Code*
3/8” NPTF
CBE*-LJN-YAB
1/2” NPTF
CBE*-LJN-YAC
3/4” NPTF
CBE*-LJN-YAD
SAE-10
CBE*-LJN-YAK
SAE-12
CBE*-LJN-YAL
C2
V2
4.00
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier
/S to order Ductile Iron for pressure rating over 3000 psi.
1.60
Max.
V1
.50
L Control
4.50
0 .50
3.25
1.75
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier
/S to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
58
US Selected Assemblies Catalogue #999-901-192
THREE PORT LOAD CONTROL APPLICATIONS
(90 DEGREE CROSS-PILOTED, 1.50” SAE C61/C62 FLANGE PORT BODIES, 2 CAVITIES)
PILOT RATIO
3:1, 1.5:1, 2:1
V1
0-60 GPM
V2
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
Cavity T-17A
2.25
1.12
C1
0
C2
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1” NPTF
CBG*-LHN-YJE
1 1/4” NPTF
CBG*-LHN-YJF
SAE-12
CBG*-LHN-YJL
SAE-16
CBG*-LHN-YJM
Mounting Holes:
.42 diameter through hole,
2 places.
L Control
0
C1
2.00
5.75
V1
V2
6.50
.75
0
2.09
0-120 GPM
V2
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1” NPTF
CBG*-LJN-YJE
1 1/4” NPTF
CBG*-LJN-YJF
SAE-12
CBG*-LJN-YJL
SAE-16
CBG*-LJN-YJM
C2
4.50
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier
/S to order Ductile Iron for pressure rating over 3000 psi.
1.84 Max.
V1
.75
4.00
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier
/S to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-19A
4.50
2.25
C1
C2
0
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1 1/2” SAE C62
CBI*-LHN-YM6
Mounting Holes: (opposite side)
.375-16 UNC-2B
x .62 deep. 4 places.
0
.52
V1
2.53
2.34 Max.
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1 1/2” SAE C61
CBI*-LJN-YM6
C1
L Control
6.50
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier
/S to order Ductile Iron for pressure rating over 3000 psi.
V1
C2
V2
8.52
9.03
0
2.41
0-120 GPM
V2
4.94
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier
/S to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-19A
4.00
2.00
C1
C2
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1 1/2” SAE C61
CBI*-LHN-YMR
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier
/S to order Ductile Iron for pressure rating over 3000 psi.
0
Mounting Holes: (opposite side)
M10 x 1.50-6H x
.62 deep. 2 places.
2.32 Max.
0
V1
2.12
C1
5.62
C2
V2
7.75
0
1.88
4.44
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1 1/2” SAE C61
CBI*-LJN-YMR
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier
/S to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
59
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT LOAD CONTROL APPLICATIONS
(INLINE/INLINE CROSS-PILOTED, 1.50” SAE C61 FLANGE PORT BODIES, 2 CAVITIES)
PILOT RATIO
3:1, 1.5:1, 2:1
V1
C1
0-15 GPM
V2
Cavity T-11A
Mounting Holes:
.34 diameter through hole
.88 diameter socket clearance.
2 places.
C2
L Control
1.28 Max.
Ports
C1, C2, V1 & V2
Assembly
Model Code*
3/8” NPTF
CBC*-LHN-XVG
2.05
SAE-6
CBC*-LHN-XVH
1.28
SAE-8
CBC*-LHN-XVI
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and must
be specified by customer. See page 50. Add modifier /S to order
Ductile Iron for pressure rating over 3000 psi.
V1
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
2.64
V1
V2
2.94 2.31
1.47
.62
3/8” NPTF
CBC*-LJN-XVG
SAE-6
CBC*-LJN-XVH
SAE-8
CBC*-LJN-XVI
C2
V2
0
0
0 .29
0
3.10 3.38
0-30 GPM
V2
Assembly
Model Code*
1.28
.66
0
Ports
C1, C2, V1 & V2
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and must
be specified by customer. See page 50. Add modifier /S to order
Ductile Iron for pressure rating over 3000 psi.
Cavity T-2A
Mounting Holes:
.34 diameter through hole
.88 diameter socket clearance.
2 places.
C1
L Control
1.66 Max.
C2
3.22
Ports
C1, C2, V1 & V2
2.56
Assembly
Model Code*
SAE-10
CBE*-LHN-XAL
SAE-12
CBE*-LHN-XAK
V1
V2
V1
3.62 2.84
1.81
1.66
.78
0
0.28
3.59 3.88
3.88
C2
Assembly
Model Code*
SAE-16
CBG*-LHN-XJM
SAE-20
CBG*-LHN-XJL
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and must
be specified by customer. See page 50. Add modifier /S to order
Ductile Iron for pressure rating over 3000 psi.
V1
V1
V2
3.63 2.37 1.13
C2
V2
.94
0
0
4.63
4.25
0-120 GPM
V2
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and must
be specified by customer. See page 50. Add modifier /S to order
Ductile Iron for pressure rating over 3000 psi.
2.28
0
4.75
CBE*-LJN-XAL
CBE*-LJN-XAK
Mounting Holes:
.42 diameter
through hole.
2.31
Ports
C1, C2, V1 & V2
SAE-10
SAE-12
Cavity T-17A
L Control
2.75 Max.
C1
Assembly
Model Code*
0
0
0-60 GPM
V2
C2
V2
.88
0
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and must
be specified by customer. See page 50. Add modifier /S to order
Ductile Iron for pressure rating over 3000 psi.
Ports
C1, C2, V1 & V2
1.66
.38 0
Cavity T-19A
Mounting Holes:
M10 x1.50-6 H x 22.4 deep.
4 places.
L Control
2.34 Max.
C1
C2
6.29
5.00
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1 1/2” SAE C61
CBIA-LHN-XZP
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and must
be specified by customer. See page 50. Add modifier /S to order
Ductile Iron for pressure rating over 3000 psi.
V2
V1
C2
2.00
0
0 1.28
1.88
6.28
5.69
0 .50
4.50
5.00
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
60
US Selected Assemblies Catalogue #999-901-192
THREE PORT LOAD CONTROL APPLICATIONS
(90 DEGREE CROSS-PILOTED BODIES WITH SHUTTLE, 2 CAVITIES)
PILOT RATIO
3:1, 1.5:1, 2:1
0-15 GPM
V1 S
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
Cavity T-11A
V2
1.25
.62
C1
C2
0
Ports
C1, C2, V1 & V2
S Port
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
CBC*-LHN-YGB
1/2” NPTF
1/4” NPTF
CBC*-LHN-YGC
Mounting Holes:
.34 diameter through hole,
2 places.
L Control
0
1.28 Max.
.38
V1
C1
1.25
SAE-6
SAE-4
CBC*-LHN-YGI
2.00
SAE-8
SAE-4
CBC*-LHN-YGJ
2.75
SAE-10
SAE-4
CBC*-LHN-YGK
S
C2
V1 S
4.00
0
.50
1.56
0-30 GPM
V2
S Port
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
CBC*-LJN-YGB
1/2” NPTF
1/4” NPTF
CBC*-LJN-YGC
SAE-6
SAE-4
CBC*-LJN-YGI
SAE-8
SAE-4
CBC*-LJN-YGJ
SAE-10
SAE-4
CBC*-LJN-YGK
V2
3.62
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Ports
C1, C2, V1 & V2
3.00
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-2A
1.50
.75
C1
0
C2
Ports
C1, C2, V1 & V2
S Port
Assembly
Model Code*
1/2” NPTF
1/4” NPTF
CBE*-LHN-YHC
3/4” NPTF
1/4” NPTF
CBE*-LHN-YHD
SAE-10
SAE-4
CBE*-LHN-YHK
SAE-12
SAE-4
CBE*-LHN-YHL
Mounting Holes:
.42 diameter through hole,
2 places.
L Control
0
C1
1.50
S
2.44
C2
3.38
V1 S
4.88
0 .50
1.75
0-60 GPM
V2
Ports
C1, C2, V1 & V2
S Port
Assembly
Model Code*
1/2” NPTF
1/4” NPTF
CBE*-LJN-YHC
3/4” NPTF
1/4” NPTF
CBE*-LJN-YHD
SAE-10
SAE-4
CBE*-LJN-YHK
SAE-12
SAE-4
CBE*-LJN-YHL
V2
4.38
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
1.60 Max.
V1
.50
3.25
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-17A
2.25
1.12
C1
Ports
C1, C2, V1 & V2
S Port
0
C2
Assembly
Model Code*
.72
CSAA-EXN
Mounting Holes:
.42 diameter through hole,
2 places.
L Control
1” NPTF
SAE-4
CBG*-LHN-YKE
0
.75
1 1/4” NPTF
SAE-4
CBG*-LHN-YKF
2.00
SAE-12
SAE-4
CBG*-LHN-YKL
SAE-16
SAE-4
CBG*LHN-YKM
V1
C1
S
3.25
4.50
Ports
C1, C2, V1 & V2
S Port
Assembly
Model Code*
1” NPTF
SAE-4
CBG*-LJN-YKE
1 1/4” NPTF
SAE-4
CBG*-LJN-YKF
SAE-12
SAE-4
CBG*-LJN-YKL
SAE-16
SAE-4
CBG*-LJN-YKM
C2
5.75
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
1.84 Max.
V2
6.50
0 .75
2.09
4.00
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
US Selected Assemblies Catalogue #999-901-192
61
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT LOAD CONTROL APPLICATIONS
(CROSS-PILOTED 1.50” SAE C61/C62 FLANGE PORT BODIES WITH SHUTTLE, 2 CAVITIES)
PILOT RATIO
3:1, 1.5:1, 2:1
0-120 GPM
V1 S
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
Cavity T-19A
V2
4.00
2.00
C1
Ports
C1, C2, V1, V2
S Port
1 1/2” SAE C61
SAE-4
C2
0
Assembly
Model Code*
.72
CSAA-EXN
Mounting Holes: (opposite side)
.375-16 UNC-2B
x .62 deep. 2 places. L Control
0
2.31 Max.
V1
CBI*-LHN-YNR
Ports
C1, C2, V1, V2
S Port
Assembly
Model Code*
1 1/2” SAE C61
SAE-4
CBI*-LJN-YNR
C1
2.12
S
C2
5.62
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
V2
7.75
0
1.88
0-120 GPM
V1 S
4.44
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-19A
V2
4.50
2.25
C1
Ports
C1, C2, V1, V2
S Port
1 1/2” SAE C62
SAE-4
C2
0
Assembly
Model Code*
.66
CSAA-EXN
Mounting Holes:
(opposite side) .375-16 UNC-2B
x .62 deep. 4 places. L Control
0
2.34 Max.
CBI*-LHN-YN6
V1
Ports
C1, C2, V1, V2
S Port
Assembly
Model Code*
1 1/2” SAE C62
SAE-4
CBI*-LJN-YN6
C1
2.53
S
6.50
C2
V2
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
9.03
0
2.41
4.94
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
62
US Selected Assemblies Catalogue #999-901-192
THREE PORT LOAD CONTROL APPLICATIONS
(INLINE CROSS-PILOTED BODIES WITH SHUTTLE, 2 CAVITIES)
PILOT RATIO
3:1, 1.5:1, 2:1
V1 S
C1
0-15 GPM
V2
Cavity T-11A
Mounting Holes:
.34 diameter through hole
.88 diameter socket
clearance. 2 places.
C2
Ports
C1, C2, V1, V2
Shuttle
Port
Assembly
Model Code*
3/8” NPTF
SAE-6
SAE-8
SAE-4
SAE-4
SAE-4
CBC*-LHN-XGB
CBC*-LHN-XGI
CBC*-LHN-XGJ
Shuttle Port
in End of Hex
L Control
1.28 Max. CSAA-EXN
2.64
2.05
1.25
V1
V2
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
C1
C2
Shuttle
Port
Assembly
Model Code*
1/2” NPTF
3/4” NPTF
SAE-4
SAE-4
CBE*-LHN-XHC
CBE*-LHN-XHD
Ports
C1, C2, V1, V2
3/4” NPTF
1” NPTF
3.38
Assembly
Model Code*
3/8” NPTF
SAE-6
SAE-8
SAE-4
SAE-4
SAE-4
CBC*-LJN-XGB
CBC*-LJN-XGI
CBC*-LJN-XGJ
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-2A
L Control
1.31 Max.
2.56
1.65
V2
3.62 2.84
V2
.88
0
.78
0
Ports
C1, C2, V1, V2
Shuttle
Port
Assembly
Model Code*
1/2” NPTF
3/4” NPTF
SAE-4
SAE-4
CBE*-LJN-XHC
CBE*-LJN-XHD
C2
0
0
0-60 GPM
V2
CSAA-EXN
3.22
V1
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
C1
Shuttle
Port
Mounting Holes:
.34 diameter through hole.
.88 diameter
socket clearance. Shuttle Ports
2 places.
in End of Hex
Ports
C1, C2, V1, V2
V1 S
Ports
C1, C2, V1, V2
0
0 .29
0-30 GPM
V2
C2
V2
0
.59 0
3.06 2.47 1.56
1.25
.66
0
V1 S
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
3.38
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-17A
Shuttle Port in end of Hex Mounting Holes:
.41 diameter
L Control
through hole.
1.81 Max.
CSAA-BXN
3.88
C2
Shuttle
Port
Assembly
Model Code*
SAE-4
SAE-4
CBE*-LHN-XKD
CBE*-LHN-XKE
2.31
V1
V2
C2
V2
.94
0
0
4.75
3.62 2.38 1.12
4.62
0
Ports
C1, C2, V1, V2
Shuttle
Port
Assembly
Model Code*
3/4” NPTF
1” NPTF
SAE-4
SAE-4
CBE*-LHN-XKD
CBE*-LHN-XKE
Ports
C1, C2, V1, V2
Shuttle
Port
Assembly
Model Code*
1 1/2” C61
SAE-4
CBE*-LJN-XZQ
0
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
V1 S
0-120 GPM
V2
Cavity T-19A
Shuttle Port in end of Hex
L Control
2.35 Max.
CSAA-BXN
6.19
C1
C2
.47
4.00
Ports
C1, C2, V1, V2
Shuttle
Port
Assembly
Model Code*
1 1/2” C61
SAE-4
CBE*-LHN-XZQ
V2
2.00
V1
C1
0
7.56
0
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
1.88
0
5.00
5.69
Mounting Holes:
M10 x1.50-6 H x .88 deep. 4 places.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
US Selected Assemblies Catalogue #999-901-192
63
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT LOAD CONTROL APPLICATIONS
(DIRECT MOUNT .75”/1.00”/1.25” SAE C61 FLANGE PORT BODIES, THROUGH PILOT)
The direct mounted SAE flange port bodies provide the opportunity to mount load control valves directly onto the ports of an actuator.
PILOT RATIO
3:1, 1.5:1, 2:1
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
0-30 GPM
2
Cavity T-2A
3
3
2.50
Ports
1 and 2
Port 3
3/4” SAE C61
SAE-6
2
1.25
1
Assembly
Model Code*
0
CBE*-LHN-ZNV
0
L Control
1.50 Max.
2
Ports
1 and 2
Port 3
Assembly
Model Code*
3/4” SAE C61
SAE-6
CBE*-LJN-ZNV
3
1.25
1
2.25
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
0
1.03
1.91
0-30 GPM
2
2.84 3.50
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
-214 O-ring
Cavity T-17A
3
3
3.00
1
Ports
1 and 2
Assembly
Model Code*
Port 3
1” SAE C61
CBG*-LHN-ZNW
SAE-6
2
1.50
Ports
1 and 2
0
0
2
1.13
Port 3
Assembly
Model Code*
1/2” NPTF
CBG*-LJN-ZNW
SAE-8
CBG*-LJN-ZNW
3
1
2.94
0
1.16 2.19
3.50 4.13
-219 O-ring
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
0-60 GPM
2
L Control
2.34 Max.
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-19A
3
3
3.50
1
Ports
1 and 2
1 1/4 SAE C61
Port 3
SAE-6
2
1.75
Assembly
Model Code*
CBG*-LHN-ZNX
0
0
L Control
2.74 Max.
2
Ports
1 and 2
1 1/4 SAE C6
Port 3
Assembly
Model Code*
CBG*-LJN-ZNX
3
1.72
1
3.44
0
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
1.44 2.62
-222 O-ring
4.81 5.50
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
64
US Selected Assemblies Catalogue #999-901-192
THREE PORT LOAD CONTROL APPLICATIONS
(DIRECT MOUNT .75”/1.00”/1.25” SAE C62 FLANGE BODIES, THROUGH PILOT)
The direct mounted SAE flange port bodies provide the opportunity to mount load control valves directly onto the ports of an actuator.
PILOT RATIO
3:1, 1.5:1, 2:1
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
0-30 GPM
2
Cavity T-2A
3
3
3.00
Ports
1 and 2
Assembly
Model Code*
Port 3
3/4” SAE C62
0
CBE*-LHN-ZDS
SAE-6
2
1.50
1
L Control
1.66 Max.
0
Ports
1 and 2
Port 3
Assembly
Model Code*
3/4” SAE C62
SAE-6
CBE*-LJN-ZDS
2
1.22
3
1
2.44
1.19
0
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
2.12
0-60 GPM
2
3.03 3.53
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
-214 O-ring
Cavity T-17A
3
3
3.50
Ports
1 and 2
Assembly
Model Code*
Port 3
1” SAE C62
0
0
CBG*-LHN-ZDR
SAE-6
2
1.75
1
L Control
1.81 Max.
Ports
1 and 2
Port 3
Assembly
Model Code*
1” SAE C62
SAE-6
CBG*-LJN-ZDR
2
3
1.72
1
3.44
0
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
1.38
2.47
0-120 GPM
2
3.69 4.31
-219 O-ring
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-19A
3
3
4.00
Ports
1 and 2
1 1/4” SAE C62
Port 3
SAE-6
2
2.00
1
Assembly
Model Code*
CBI*-LHN-ZFD
0
0
L Control
2.31 Max.
2
1.97
Ports
1 and 2
Port 3
Assembly
Model Code*
1 1/4” SAE C62
SAE-6
CBI*-LJN-ZFD
3
1
3.94
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
0
1.53
2.78
-222 O-ring
4.88 5.62
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
US Selected Assemblies Catalogue #999-901-192
65
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT LOAD CONTROL APPLICATIONS
(GASKET MOUNT BODIES)
These compact gasket-mounted bodies provide the opportunity to mount load control valves directly onto the ports of an actuator.
PILOT RATIO
3:1, 1.5:1, 2:1
V2
0-15 GPM
V1
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
Cavity T-11A
Mounting Holes: .34 diameter through hole,
2 places.
C1
L Control
1.28 Max.
2.50
V1
2.00
C2
1.63
Ports
C2, V1 & V2
Assembly
Model Code*
1.03
.81
3/8” NPTF
CBC*-LHN-ZTN
SAE-6
CBC*-LHN-ZTC
.50
.31
0
V2
C1
C2
.50
Assembly
Model Code*
3/8” NPTF
CBC*-LJN-ZTN
SAE-6
CBC*-LJN-ZTC
3.75
1.00
0
Ports
C2, V1 & V2
0
.59
*The asterisk (*) shown in the fourth digit of the model
code indicates the counterbalance pilot ratio of the
cartridge and must be specified by customer. See page
50. Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
V2
1.19
0-30 GPM
V1
*The asterisk (*) shown in the fourth digit of the model code indicates
the counterbalance pilot ratio of the cartridge and must be specified by
customer. See page 50. Add modifier /S to order Ductile Iron for
pressure rating over 3000 psi.
-113 O-ring
Cavity T-2A
Mounting Holes:
.42 diameter through hole,
2 places.
C1
V1
2.38
C2
L Control
1.63 Max.
3.00
1.94
Ports
C2, V1 & V2
Assembly
Model Code*
1/2” NPTF
CBE*-LHN-ZTF
SAE-8
CBE*-LHN-ZTG
1.22
.94
.63
.34
0
V2
0
Ports
C2, V1 & V2
C1
C2
.63
1.22
Assembly
Model Code*
1/2” NPTF
CBE*-LJN-ZTF
SAE-8
CBE*-LJN-ZTG
4.25
1.44
.72
*The asterisk (*) shown in the fourth digit of the model
code indicates the counterbalance pilot ratio of the
cartridge and must be specified by customer. See page
50. Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
V2
-117 O-ring
0-60 GPM
V1
*The asterisk (*) shown in the fourth digit of the model code indicates
the counterbalance pilot ratio of the cartridge and must be specified by
customer. See page 50. Add modifier /S to order Ductile Iron for
pressure rating over 3000 psi.
0
Cavity T-17A
Mounting Holes: .53 diameter through hole,
counterbore .78 diameter
L Control
x .44 deep. 2 places.
C1
4.00
C2
Assembly
Model Code*
1.56
3/4” NPTF
CBG*-LHN-ZTJ
1.06
SAE-12
CBG*-LHN-ZTK
Ports
C2, V1 & V2
1.69 Max.
3.25
2.69
V1
Ports
C2, V1 & V2
C1
C2
V2
.44
0
0
1.44
Assembly
Model Code*
3/4” NPTF
CBG*-LJN-ZTJ
SAE-12
CBG*-LJN-ZTK
5.47
0
1.09
*The asterisk (*) shown in the fourth digit of the model
code indicates the counterbalance pilot ratio of the
cartridge and must be specified by customer. See page
50. Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
*The asterisk (*) shown in the fourth digit of the model code indicates
the counterbalance pilot ratio of the cartridge and must be specified by
customer. See page 50. Add modifier /S to order Ductile Iron for
pressure rating over 3000 psi.
2.19
-121 O-ring
Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
66
US Selected Assemblies Catalogue #999-901-192
THREE PORT LOAD CONTROL APPLICATIONS
(GASKET MOUNT BODIES, 2 CAVITIES)
The gasket-mounted bodies provide the opportunity to mount load control valves directly onto the ports of an actuator.
PILOT RATIO
3:1, 1.5:1
V2
PILOT RATIO
2.3:1, 4.5:1, 10:1
Go to www.sunhydraulics.com
for more product information and pricing.
0-15 GPM
V1
Cavity T-11A
0
C1
C2
1.28
Max.
1.69
2.19
Ports
C2, V1 & V2
Assembly
Model Code*
3/8” NPTF
CBC*-LHN-YVM
SAE-6
CBC*-LHN-YVY
-113 O-ring
Mounting Holes: (opposite side)
.34 diameter through hole, counterbore .50
diameter x .25 deep. 2 places.
C1
C2
L Control
1.28 Max.
0
0
1.00
0-30 GPM
V1
3/8” NPTF
CBC*-LJN-YVM
SAE-6
CBC*-LJN-YVY
V1
V2
V2
Assembly
Model Code*
2.50
2.00
1.62
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /
S to order Ductile Iron for pressure rating over 3000 psi.
Ports
C2, V1 & V2
3.75
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /
S to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-2A
0
.81
C1
C2
1.63
Max.
2.75
Ports
C2, V1 & V2
Assembly
Model Code*
1/2” NPTF
CBE*-LHN-YVW
SAE-8
CBE*-LHN-YVV
-117 O-ring
Mounting Holes: .41 diameter through hole,
counterbore .59 diameter
L Control
2 places.
3.00
C1
CBE*-LJN-YVW
SAE-8
CBE*-LJN-YVV
C2
.34
0
0
1.22
0-60 GPM
V1
1/2” NPTF
V1
V2
V2
Assembly
Model Code*
1.63 Max.
2.38
1.94
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /
S to order Ductile Iron for pressure rating over 3000 psi.
Ports
C2, V1 & V2
4.25
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /
S to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-17A
0
C1
C2
1.69
Max.
2.50
3.94
Ports
C2, V1 & V2
Assembly
Model Code*
3/4” NPTF
CBG*-LHN-YVT
SAE-12
CBG*-LHN-YVS
-121 O-ring
Mounting Holes: (opposite side)
.53 diameter through hole, counterbore .78
diameter x .44 deep. 2 places.
CBG*-LJN-YVT
SAE-12
CBG*-LJN-YVS
V1
C1
.44
0
C2
L Control
1.69 Max
V2
1.44
5.47
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /
S to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge models CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
US Selected Assemblies Catalogue #999-901-192
Assembly
Model Code*
3/4” NPTF
4.00
3.25
2.69
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 50. Add modifier /
S to order Ductile Iron for pressure rating over 3000 psi.
Ports
C2, V1 & V2
67
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
THREE PORT
COUNTERBALANCE
Line Mounted Assemblies
NOTES
68
US Selected Assemblies Catalogue #999-901-192
Four Port Counterbalance Assemblies
Cartridge Type
Page
4
3
2
Vented, 4000 psi Maximum Setting
Vented, 6000 psi Maximum Setting
70
70
1
Line Mounted Assemblies
(Body Type)
4
3
2
90 Degree
72
90 Degree with Gauge Port
73
2.00” SAE C62 Flange Port, 2 Cavities
74
90 Degree Cross-Piloted, 2 Cavities, Common Port 4
75
1
3
2
4
G
1
4
3
2
1
2A
2B
4
1A
1B
US Selected Assemblies Catalogue #999-901-192
69
FOUR PORT
COUNTERBALANCE
Counterbalance Valves
VENTED, 4000 PSI MAXIMUM SETTING
4
Capacity
Cavity
a
15 GPM
CWCA– LHN
T - 21A
1.38
30 GPM
CWEA– LHN
T - 22A
1.38
1 1/8”
3.29
3.54
45/50
60 GPM
CWGA– LHN
T - 23A
1.81
1 1/4”
3.75
3.97
150/160
120 GPM
CWIA – LHN
T - 24A
2.50
1 7/8”
4.58
4.78
350/375
3
2
1
Cartridge Dimensions
c
b
L
Typical
Cartridge
Model Code
7/8”
2.91
C
3.16
Installation
Torque
(lb. ft.)
30/35
OPTION ORDERING INFORMATION
CW ✱ ✱ – ✱ ✱ ✱
Turn screw clockwise to reduce
setting and release load.
Complete Adjustment 5 Turns
+
b
Nominal
Capacity
C 15 GPM
L Standard Screw
E 30 GPM
C Tamper Resistant
I
4
Vent
Seal
N Buna-N
A and K Pilot Ratios
H 1000 - 4000 psi
I
V Viton
400 - 1500 psi
Version
120 GPM
A 3:1 Pilot Ratio
K 1:1 Pilot Ratio
Locating
Shoulder
2
Valve
Cracking Pressure
G 60 GPM
c
3
Pilot
Control**
a
Adjustment Range Options:
H is standard set at 3000 psi.
I is standard set at 1000 psi.
Customer may specify setting.
** See page 244 for information
on Control Options
Load 1
VENTED, 6000 PSI MAXIMUM SETTING
4
Capacity
3
2
1
Typical
Cartridge
Model Code
Cavity
a
Cartridge Dimensions
c
b
L
C
Installation
Torque
(lb. ft.)
30/35
15 GPM
CWCG– LFN
T - 21A
1.38
7/8”
2.91
30 GPM
CWEG– LFN
T - 22A
1.38
1 1/8”
3.29
3.54
45/50
60 GPM
CWGG– LFN
T - 23A
1.81
1 1/4”
3.75
3.97
150/160
120 GPM
CWIG – LFN
T - 24A
2.50
1 7/8”
4.58
4.78
350/375
3.16
OPTION ORDERING INFORMATION
CW ✱ ✱ – ✱ ✱ ✱
Turn screw clockwise to reduce
setting and release load.
Complete Adjustment 5 Turns
+
b
Nominal
Capacity
C 15 GPM
L Standard Screw
E 30 GPM
C Tamper Resistant
G 60 GPM
c
I
4
Vent
3
Pilot
Locating
Shoulder
2
Valve
Load 1
Control**
Cracking Pressure
G and L Pilot Ratios
F 1000 - 3500 psi
Seal
N Buna-N
V Viton
G 2000 - 6000 psi
Version
120 GPM
G 5:1 Pilot Ratio
L 2:1 Pilot Ratio
a
** See page 244 for information
on Control Options
70
Adjustment Range Options:
F is standard set at 2000 psi.
G is standard set at 4000 psi.
Customer may specify setting.
US Selected Assemblies Catalogue #999-901-192
Counterbalance Valves, 3:1, 5:1, 1:1 and 2:1 Pilot Ratios, Vented
Performance Curves
Free Flow and Pilot Open Pressure Drop
CWC*-L*N
P = psi
300
200
Free Flow
100
Piloted Open
0
0
5
10
15
Q = GPM
CWE*-L*N
P = psi
300
200
Free Flow
100
Piloted Open
0
0
10
20
30
Q = GPM
CWG*-L*N
P = psi
300
200
Free Flow
100
Piloted Open
0
0
40
20
60
Q = GPM
CWI*-L*N
300
P = psi
Applications
Sun counterbalance valves with pilot assist are used
for load holding and to provide smooth motion
control. When used with vertical actuators they help to
ensure control of the load during lowering. With
horizontal rotary motion, such as slewing, they can
help provide good control of acceleration and
deceleration.
The vented type are used to provide load control on
applications where there is a variable back-pressure
downstream of the valve which could cause instability
in a standard valve. The spring chamber is vented
externally to tank through a fourth port making it
insensitive to back pressure. Any pressure generated
on the drain port will be additive to the setting.
Counterbalance valves are load control valves and
not speed control valves. Separate meter-in flow
control valves should be included to provide speed
control. It is always better to undersize rather than
oversize the valve used and mount it as close to the
actuator as possible. It is always advisable to set the
pressure setting of a counterbalance valve before
fitting it to the application as it is difficult to set up on
a machine.
It is always advisable to select a low pilot ratio to
provide the best stability, particularly on cylinder
applications. High pilot ratios should only be used on
stable motor applications.
Design Concepts and Features
■
All cartridges are fully tested and supplied at a
standard setting. The setting of a counterbalance
valve is always the cracking pressure.
■
The valve reseats after opening at 85% of the
cracking pressure.
■ Maximum leakage on reseat is 5 drops/min.
■
The standard free reverse flow check varies
between 20 psi and 45 psi depending on the frame
size.
■
Recommended setting for counterbalance valves is
1.3 times the maximum load induced pressure.
■ Increase setting by turning adjust screw
anti-clockwise.
■
The valve is opened by a combination of the load
induced pressure on the main seat area and the
pilot pressure on the pilot area.
■ The cartridge has a sealed pilot.
■ All cartridges have 3 nominal adjustment turns
from minimum to maximum pressure setting.
■
A press fit tamper resistant cap is available to fit
over the screw adjustment.
■
Valves are unaffected by back pressure at Port 2.
■ Vent port should not be blocked.
200
Free Flow
100
Piloted Open
0
0
40
80
120
Q = GPM
General Application Requirements
■
■
■
■
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at cracking flow.
US Selected Assemblies Catalogue #999-901-192
71
FOUR PORT
COUNTERBALANCE
TECHNICAL TIPS / PERFORMANCE CURVES
FOUR PORT
COUNTERBALANCE
Line Mounted Assemblies
FOUR PORT LOAD CONTROL APPLICATIONS
(90 DEGREE BODIES)
PILOT RATIO
3:1, 1:1
PILOT RATIO
4.5:1, 2:1
Go to www.sunhydraulics.com
for more product information and pricing.
0-15 GPM
4
Cavity T-21A
3
2
1.25
.62
1
0
Ports
1 and 2
Ports
3 and 4
Assembly
Model Code*
3/8” NPTF
3: 3/8” NPTF
4: 1/4” NPTF
CWC*-LHN-MAB
1/2” NPTF
3: 3/8” NPTF
4: 1/4” NPTF
CWC*-LHN-MAC
3: SAE-6
4: SAE-6
CWC*-LHN-MAI
3: SAE-8
4: SAE-6
CWC*-LHN-MAJ
3: SAE-8
4: SAE-6
CWC*-LHN-MAK
SAE-6
SAE-8
SAE-10
Mounting Holes:
.34 diameter through hole
2 places.
0
.38
2
L Control
1.66 Max.
4
1
1.25
Ports
3 and 4
Assembly
Model Code*
3/8” NPTF
3: 3/8” NPTF
4: 1/4” NPTF
CWC*-LGN-MAB
1/2” NPTF
3: 3/8” NPTF
4: 1/4” NPTF
CWC*-LGN-MAC
SAE-6
3: SAE-6
4: SAE-6
CWC*-LGN-MAI
SAE-8
3: SAE-8
4: SAE-6
CWC*-LGN-MAJ
SAE-10
3: SAE-8
4: SAE-6
CWC*-LGN-MAK
3
2.50
0 .44
1.59
2.56 3.12 3.56
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
0-30 GPM
4
Ports
1 and 2
Cavity T-22A
3
2
1.50
.75
1
0
Ports
1 and 2
Ports
3 and 4
Assembly
Model Code*
1/2” NPTF
3: 1/2” NPTF
4: 1/4” NPTF
CWE*-LHN-NAC
3/4” NPTF
3: 1/2” NPTF
4: 1/4” NPTF
CWE*-LHN-NAD
3: SAE-8
4: SAE-6
CWE*-LHN-NAJ
3: SAE-10
4: SAE-6
CWE*-LHN-NAK
SAE-8
SAE-10
0
Mounting Holes:
.42 diameter through hole
2 places.
2
.50
1.50
4
L Control
1.98 Max.
1
Ports
1 and 2
Ports
3 and 4
Assembly
Model Code*
1/2” NPTF
3: 1/2” NPTF
4: 1/4” NPTF
CWE*-LGN-NAC
3/4” NPTF
3: 1/2” NPTF
4: 1/4” NPTF
CWE*-LGN-NAD
SAE-8
3: SAE-8
4: SAE-6
CWE*-LGN-NAJ
SAE-10
3: SAE-10
4: SAE-6
CWE*-LGN-NAK
3
3.00
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
0 .44
1.72
2.69 3.31 3.75
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 70 for cartridge models CW**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
72
US Selected Assemblies Catalogue #999-901-192
FOUR PORT
COUNTERBALANCE
Line Mounted Assemblies
FOUR PORT LOAD CONTROL APPLICATIONS
(90 DEGREE BODIES)
PILOT RATIO
3:1, 1:1
PILOT RATIO
5:1, 2:1
Go to www.sunhydraulics.com
for more product information and pricing.
3
0-60 GPM
Cavity T-23A
2
4
G
1
2.25
1.13
0
Ports
1 and 2
Ports
3 and 4
Assembly
Model Code*
1” NPTF
3: 3/4” NPTF
4: 1/4” NPTF
CWG*-LHN-PAE
0
1 1/4” NPTF
3: 3/4” NPTF
4: 1/4” NPTF
CWG*-LHN-PAF
.75
SAE-12
3: SAE-12
4: SAE-6
CWG*-LHN-PAL
2.00
SAE-16
3: SAE-12
4: SAE-6
CWG*-LHN-PAM
Mounting Holes:
.42 diameter through hole, 2 places.
2
L Control
2.16 Max.
4
1
Ports
1 and 2
Ports
3 and 4
Assembly
Model Code*
1” NPTF
3: 3/4” NPTF
4: 1/4” NPTF
CWG*-LGN-PAE
1 1/4” NPTF
3: 3/4” NPTF
4: 1/4” NPTF
CWG*-LGN-PAF
SAE-12
3: SAE-12
4: SAE-6
CWG*-LGN-PAL
SAE-16
3: SAE-12
4: SAE-6
CWG*-LGN-PAM
3
G
4.00
0
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
1.09
2.12
0-120 GPM
4
3.41 4.25 4.75
1/4” NPTF Gauge Port
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-24A
3
2
3.00
1.50
1
0
Ports
1 and 2
Ports
3 and 4
Assembly
Model Code*
1” NPTF
1/4” NPTF
CWI*-LHN-QCE
1 1/4” NPTF
1/4” NPTF
CWI*-LHN-QCF
SAE-16
SAE-6
CWI*-LHN-QCM
SAE-20
SAE-6
CWI*-LHN-QCN
Mounting Holes:
.42 diameter through hole, 2 places.
0
.50
2
4
L Control
2.61 Max.
1
2.50
Ports
1 and 2
Ports
3 and 4
Assembly
Model Code*
CWI*-LGN-QCE
1” NPTF
1/4” NPTF
1 1/4” NPTF
1/4” NPTF
CWI*-LGN-QCF
SAE-16
SAE-6
CWI*-LGN-QCM
SAE-20
SAE-6
CWI*-LGN-QCN
3
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
5.00
0
2.50
4.28 5.31 5.88
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 70 for cartridge models CW**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
73
FOUR PORT
COUNTERBALANCE
Line Mounted Assemblies
FOUR PORT LOAD CONTROL APPLICATIONS
(2.00” SAE C62 FLANGE PORT BODY, 2 CAVITIES)
PILOT RATIO
3:1, 1:1
0-240 GPM
4
Cavity T-24A
3
2
0
2.26
7.78
0
0
4
1.06
1
Ports
1 and 2
2” SAE C62
PILOT RATIO
4:5:1, 2:1
Go to www.sunhydraulics.com
for more product information and pricing.
Ports
3 and 4
SAE-6
2.97
Assembly
Model Code*
CWI*-LHN-Z9T
4.88
3
5.94
0
Mounting Holes:
.500-13 UNC-2B x .87 DP.
0
4.97
0
2.97
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
1
6.75
8.34
Ports
1 and 2
Ports
3 and 4
Assembly
Model Code*
2” SAE C62
SAE-6
CWI*-LGN-Z9T
L Control
2.58 Max.
2
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
5.94
NOTES: Page 70 for cartridge models CW**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
74
US Selected Assemblies Catalogue #999-901-192
FOUR PORT
COUNTERBALANCE
Line Mounted Assemblies
FOUR PORT LOAD CONTROL APPLICATIONS
(90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES, COMMON PORT 4)
PILOT RATIO
3:1, 1:1
2A
PILOT RATIO
5:1, 2:1
Go to www.sunhydraulics.com
for more product information and pricing.
0-15 GPM
2B
Cavity T-21A
1.25
4
.62
1A
0
1B
Ports
1A, 1B, 2A & 2B
Port 4
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
CWC*-LHN-XPB
1/2” NPTF
1/4” NPTF
CWC*-LHN-XPC
SAE-6
SAE-6
SAE-8
SAE-10
Mounting Holes:
.34 diameter through holes, 2 places.
Ports
1A, 1B, 2A & 2B
Port 4
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
CWC*-LFN-XPB
1/2” NPTF
1/4” NPTF
CWC*-LFN-XPC
CWC*-LHN-XPI
SAE-6
SAE-6
CWC*-LFN-XPI
SAE-6
CWC*-LHN-XPJ
SAE-8
SAE-6
CWC*-LFN-XPJ
SAE-6
CWC*-LHN-XPK
SAE-10
SAE-6
CWC*-LFN-XPK
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
2A
0
.38
2B
1B
1.25
1A
2.75
2A
3.62
4.00
0 .50
1.59
0-30 GPM
2B
L Control
1.66 Max.
4
3.12 3.56
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-22A
2.00
4
1.00
1A
1B
0
Ports
1A, 1B, 2A & 2B
Port 4
Assembly
Model Code*
1/2” NPTF
1/4” NPTF
CWE*-LHN-XIC
3/4” NPTF
1/4” NPTF
CWE*-LHN-XID
SAE-6
SAE-6
SAE-8
SAE-6
0
.75
Mounting Holes:
.42 diameter through hole, 2 places.
2B
4
L Control
1.98 Max.
Ports
1A, 1B, 2A & 2B
Port 4
Assembly
Model Code*
1/2” NPTF
1/4” NPTF
CWE*-LFN-XIC
3/4” NPTF
1/4” NPTF
CWE*-LFN-XID
CWE*-LHN-XII
SAE-6
SAE-6
CWE*-LFN-XII
CWE*-LHN-XIJ
SAE-8
SAE-6
CWE*-LFN-XIJ
1.62
3.38
1B
1A
2A
4.25
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
5.00
0 .50
1.72
3.31 4.00
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 70 for cartridge models CW**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
US Selected Assemblies Catalogue #999-901-192
75
FOUR PORT
COUNTERBALANCE
Line Mounted Assemblies
FOUR PORT LOAD CONTROL APPLICATIONS
(90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES, COMMON PORT 4)
PILOT RATIO
3:1, 1:1
2A
PILOT RATIO
5:1, 2:1
Go to www.sunhydraulics.com
for more product information and pricing.
0-60 GPM
2B
Cavity T-23A
2.00
4
1.00
1A
Ports
1A 1B, 2A & 2B
1B
0
Assembly
Model Code*
Port 4
1” NPTF
1/4” NPTF
CWG*-LHN-XME
1 1/4” NPTF
1/4” NPTF
CWG*-LHN-XMF
SAE-12
1/4” NPTF
CWG*-LHN-XML
SAE-16
1/4” NPTF
CWG*-LHN-XMM
Mounting Holes:
.42 diameter through hole, 2 places.
0
.75
2B
1B
1.62
1A
3.38
2A
5.00
0 .50
1.72
0-120 GPM
2B
Ports
1A 1B, 2A & 2B
Port 4
Assembly
Model Code*
CWG*-LFN-XME
1” NPTF
1/4” NPTF
1 1/4” NPTF
1/4” NPTF
CWG*-LFN-XMF
SAE-12
1/4” NPTF
CWG*-LFN-XML
SAE-16
1/4” NPTF
CWG*-LFN-XMM
2A
4.25
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
L Control
1.98 Max.
4
3.31 4.00
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Cavity T-24A
3.00
4
1.50
1A
Ports
1A 1B, 2A & 2B
Port 4
1B
0
Assembly
Model Code*
1” NPTF
1/4” NPTF
CWI*-LHN-XLE
1 1/4” NPTF
1/4” NPTF
CWI*-LHN-XLF
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
Mounting Holes:
.42 diameter through hole, 2 places.
0
.62
2B
2.12
1B
4.88
1A
4
L Control
2.58 Max.
Ports
1A 1B, 2A & 2B
Port 4
Assembly
Model Code*
1” NPTF
1/4” NPTF
CWI*-LFN-XLE
1 1/4” NPTF
1/4” NPTF
CWI*-LFN-XLF
2A
6.38
7.00
0 .62
2.62
5.44 6.00
*The asterisk (*) shown in the fourth digit of the model code
indicates the counterbalance pilot ratio of the cartridge and
must be specified by customer. See page 70. Add modifier /S
to order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 70 for cartridge models CW**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
76
US Selected Assemblies Catalogue #999-901-192
Three Port Pilot-to-Open Check Assemblies
Cartridge Type
2
Page
3
Pilot Operated
78
1
Line Mounted Assemblies
(Body Type)
2
3
1
V1
90 Degree
Inline
90 Degree 2” SAE C61/C62 Flange Port, 2 Cavities
80
82
84
90 Degree Cross-Piloted, 2 Cavities
85
Inline Cross-Piloted, 2 Cavities
88
Direct Mount .75”/1.00”/1.25” SAE C61 Flange Port/
Gasket Mount, Through Pilot Port
Direct Mount .75”/1.00”/1.25” SAE C62 Flange Port/
Gasket Mount, Through Pilot Port
89
Gasket Mount
91
Gasket Mount, 2 Cavities
92
V2
C1
C2
V1
V2
C1
C2
3
3
2
1
V2
90
V1
C1
C2
V1
C1
V2
C2
US Selected Assemblies Catalogue #999-901-192
77
THREE PORT
PILOT-TO-OPEN CHECK
Pilot-to-Open Check Valves
PILOT OPERATED
Ext.
Full Adjustment 5 Turns
+
-
2
L Control
3
2
3
X Control
b
c
3
Pilot
Locating
Shoulder
2
Valve
Load 1
a
1
1
X, L Controls
B, E, P Controls
Cartridge Dimensions
c
b
X,B,E,P
Capacity
Typical
Cartridge
Model Code
7.5 GPM
CKBB – XCN
T - 163A
1.22
3/4”
1.25
2.55
Installation
Torque
(lb. ft.)
25/30
15 GPM
CKCB – XCN
T - 11A
1.38
7/8”
1.19
2.50
30/35
30 GPM
CKEB – XCN
T - 2A
1.38
1 1/8”
1.38
2.81
45/50
60 GPM
CKGB – XCN
T - 17A
1.81
1 1/4”
1.81
3.28
150/160
120 GPM
CKIB – XCN
T - 19A
2.50
1 5/8”
2.31
3.94
350/375
Cavity
a
L
OPTION ORDERING INFORMATION
CK ✱ ✱
Nominal
Capacity
Version
–
✱✱✱
Control**
Cracking Pressure
Seal
B *7.5 GPM
B Bleed through Pilot
X Standard Pilot
A 4 psi
N Buna-N
C 15 GPM
D Sealed Pilot Piston
L Manual Load
Release
B 15 psi
V Viton
E 30 GPM
G 60 GPM
I
120 GPM
B 1/4" BSPP External
Pilot Port 3 blocked
E SAE-4 External
Pilot Port 3 blocked
P 1/4" NPTF External
Pilot Port 3 blocked
** See page 244 for information
on Control Options
78
C 30 psi
D 50 psi
E 75 psi
F 100 psi
*CKBB, CKBD available
with C and E Cracking
Pressure Only.
US Selected Assemblies Catalogue #999-901-192
THREE PORT
PILOT-TO-OPEN CHECK
TECHNICAL TIPS / PERFORMANCE CURVES
Pilot-to-Open Check Valves, External Pilot, Non-vented
Note: Pressure at port 2 is directly additive to the pilot pressure
required at port 3 (pilot). For applications where this occurs, a 4 port
vented pilot operated check cartridge (CV*V-***) should be
considered.
Performance Curves
Typical Pressure Drop
CKCB-X*N
480
480
400
300
400
210
140
XEN
70
XCN
0
2.5
5
P = psi
P = psi
CKBB-X*N
OT
PIL
LL
FU
7.5
Flow = GPM
140
480
400
300
210
OT
PIL
LL
FU
XEN
XCN
0
7.5
15
22.5
Flow = GPM
300
210
140
70
30
0
400
300
210
OT
PIL
LL
FU
XEN
XCN
40
80
120
160
Flow = GPM
General Application Requirements
■
■
■
■
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at cracking flow.
US Selected Assemblies Catalogue #999-901-192
79
20
XCN
480
0
15
OT
PIL
LL
FU
XEN
CKIB-X*N
140
70
10
CKGB-X*N
400
70
5
Flow = GPM
480
140
OT
PIL
LL
FU
XEN
XCN
0
10
P = psi
P = psi
300
210
70
CKEB-X*N
P = psi
Applications
Pilot operated checks are used to hold loads in
position and for that reason should be mounted as
close to the actuator as possible. Pilot-to-open checks
are non-modulating, on/off devices that allow free
flow through the check valve from port 2 (valve) to
port 1 (load). Reverse flow is blocked until a pilot
pressure directly proportional to the load pressure is
sensed at port 3 (pilot), so that a pilot piston displaces
the check from its seat.
Design Concepts and Features
■
3:1 pilot ratio is suitable for most applications.
■
Low leakage when closed, less than 1 drop/min.
■
Optional, emergency manual release screw, in case
pilot pressure is not available.
■ Pilot piston leakage is present on CK*B models
between port 3 and port 2 in order to purge trapped
air in the pilot line. Optional models (CK*D)
feature a sealed pilot piston for applications where
cross-port leakage is undesirable.
20
40
60
Flow = GPM
80
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(90 DEGREE BODIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-7.5 GPM
2
Cavity T-163A
3
1.00
.50
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1/4” NPTF
1/4” NPTF
CKBB-XCN-JCA
3/8” NPTF
1/4” NPTF
CKBB-XCN-JCB
SAE-4
SAE-4
CKBB-XCN-JCH
SAE-6
SAE-4
CKBB-XCN-JCI
Mounting Holes:
.28 diameter through hole
2 places.
0
.28
L Control
1.91 Max.
2
1
.97
3
2.00
1.31
0
2.14 2.59
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-15 GPM
2
Cavity T-11A
3
1.25
.62
0
1
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
CKCB-XCN-ECB
1/2” NPTF
1/4” NPTF
CKCB-XCN-ECC
SAE-4
SAE-4
CKCB-XCN-ECH
SAE-6
SAE-6
CKCB-XCN-ECI
SAE-8
SAE-6
CKCB-XCN-ECJ
Mounting Holes:
.34 diameter through hole
2 places.
0
.38
L Control
1.81 Max.
2
1
1.25
3
2.50
1.56
0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
2.53 3.00
0-30 GPM
2
3
Cavity T-2A
1.50
.75
0
1
Ports
1 and 2
Port 3
Assembly
Model Code*
1/2” NPTF
1/4” NPTF
CKEB-XCN-BCC
3/4” NPTF
1/4” NPTF
CKEB-XCN-BCD
SAE-6
SAE-6
CKEB-XCN-BCI
SAE-8
SAE-6
CKEB-XCN-BCJ
0
Mounting Holes:
.42 diameter through hole
2 places.
2.02
Max.
2
.50
1
1.62
L Control
3
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
3.00
0
1.72
2.66 3.25
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
80
US Selected Assemblies Catalogue #999-901-192
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(90 DEGREE BODIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-60 GPM
2
Cavity T-17A
3
2.25
2.12
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
CKGB-XCN-HCE
1 1/4” NPTF
1/4” NPTF
CKGB-XCN-HCF
SAE-12
SAE-6
CKGB-XCN-HCL
SAE-16
SAE-6
CKGB-XCN-HCM
0
Mounting Holes:
.42 diameter through hole
2 places.
L Control
2.16 Max.
2
.75
1
2.00
3
4.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
2.12
0
0-120 GPM
2
3.50 4.25
Cavity T-19A
3
3.00
1.50
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1/4” NPTF
CKIB-XCN-KCE
1 1/4” NPTF
1/4” NPTF
CKIB-XCN-KCF
SAE-16
SAE-6
CKIB-XCN-KCM
SAE-20
SAE-6
CKIB-XCN-KCN
0
.50
Mounting Holes:
.42 diameter through hole
2 places.
L Control
2.78 Max.
2
1
2.25
3
4.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0
2.47
4.25 5.00
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
81
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(INLINE BODIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-7.5 GPM
2
Cavity T-163A
3
Mounting Holes:
.28 diameter through
2 places.
Counterbore for
1/4 bolt.
1
Ports
1 and 2
Port 3
1/4” NPTF
1/4” NPTF
CKBB-XCN-JJA
3/8” NPTF
1/4” NPTF
CKBB-XCN-JJB
L Control
1.25 Max.
Assembly
Model Code*
SAE-4
SAE-4
CKBB-XCN-JJH
SAE-6
SAE-4
CKBB-XCN-JJI
2.64
1.94
3
1.28
1.25
2
.64
0
1.62 1.12
0
1
0
0
3.38
0
2.13
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-15 GPM
2
Cavity T-11A
3
Mounting Holes:
.34 diameter through
2 places.
Counterbore for
5/16 bolt.
1
L Control
1.81 Max.
Ports
1 and 2
Port 3
Assembly
Model Code*
2.64
3/8” NPTF
1/4” NPTF
CKCB-XCN-EJB
2.05
SAE-6
SAE-6
CKCB-XCN-EJI
SAE-8
SAE-6
3
1.25
1.28
CKCB-XCN-EJJ
2
.66
0
1.78 1.16 .31 0
1
0
0
0 .29
1.26
3.38
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
82
US Selected Assemblies Catalogue #999-901-192
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(INLINE BODIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-30 GPM
2
Cavity T-2A
3
Mounting Holes:
.34 diameter through hole
Counterbore for hex
head bolt.
2 places.
1
L Control
2.09 Max.
Ports
1 and 2
Port 3
Assembly
Model Code*
1/2” NPTF
3.22
1/4” NPTF
CKEB-XCN-BVC
2.56
3/4” NPTF
1/4” NPTF
CKEB-XCN-BVD
SAE-6
SAE-6
CKEB-XCN-BVI
SAE-8
SAE-6
CKEB-XCN-BVJ
3
1.68
1.66
2
.88
0
2.12 1.34
1
0
.31 0
0
0
1.44
3.88
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-60 GPM
2
Cavity T-17A
3
Mounting Holes:
.42 diameter through hole.
1.00 diameter counterbore.
2 places.
1
L Control
2.37 Max.
Ports
1 and 2
Port 3
Assembly
Model Code*
3.88
3/4” NPTF
1/4” NPTF
CKGB-XCN-HDD
3.16
1” NPTF
1/4” NPTF
CKGB-XCN-HDE
2.28
SAE-12
SAE-6
CKGB-XCN-HDL
SAE-16
SAE-6
CKGB-XCN-HDM
3
2.28
2
.94
0
3.00
1.69
.38 0
1
0
0
0 .38
1.96
4.62
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
83
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(90 DEGREE 2.00” SAE C61/C62 FLANGE PORT BODIES, 2 CAVITIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-240 GPM
2
Cavity T-19A
3
5.94
2.97
1
Ports
1 and 2
Port 3
Assembly
Model Code*
2” SAE C61
SAE-6
CKIB-XCN-XZZ
0
Mounting Holes:
.375-16 UNC-2B x 15,7 mm deep.
2 places.
L Control
0
2.77
2
Max.
.97
3
1
2.88
4.97
5.94
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0
1.97
0-240 GPM
2
3
4.25 6.03 6.75
Cavity T-19A
5.94
2.97
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
2” SAE C62
SAE-6
CKIB-XCN-Z8Z
Mounting Holes:
.500-13 UNC-2B x .87 deep. 2 places.
L Control
2.78 Max.
0
2
1.06
1
2.97
3
4.88
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
5.94
0
2.26
4.97
7.50
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
84
US Selected Assemblies Catalogue #999-901-192
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-7.5 GPM
V1
V2
Cavity T-163A
1.00
.50
0
C1
Mounting Holes:
.28 diameter through hole, 2 places.
C2
0
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1/4” NPTF
CKBB-XCN-JYA
3/8” NPTF
CKBB-XCN-JYB
1/2” NPTF
CKBB-XCN-JYH
SAE-6
CKBB-XCN-JYI
1.06
C1
2.44
C2
V2
3.12
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3.50
.50
0
1.50
0-15 GPM
V1
V2
L Control
1.94 Max.
V1
.38
2.75
Cavity T-11A
1.25
.62
0
C1
Mounting Holes:
.34 diameter through hole, 2 places.
C2
0
.38
Ports
C1, C2, V1 & V2
Assembly
Model Code*
3/8” NPTF
CKCB-XCN-YEB
1/2” NPTF
CKCB-XCN-YEC
SAE-6
CKCB-XCN-YEI
SAE-8
CKCB-XCN-YEJ
SAE-10
CKCB-XCN-YEK
L Control
1.81 Max.
V1
1.25
C1
2.75
C2
V2
3.62
4.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
.50
1.56
3.00
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
85
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-30 GPM
V1
V2
Cavity T-2A
1.50
.75
0
C1
C2
Mounting Holes:
.42 diameter through hole, 2 places.
0
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1/2” NPTF
CKEB-XCN-YAC
3/4” NPTF
CKEB-XCN-YAD
SAE-8
CKEB-XCN-YAJ
SAE-10
CKEB-XCN-YAK
1.50
C1
3.00
C2
V2
4.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.06 Max.
V1
.50
L Control
4.50
0 .50
1.75
3.25
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
86
US Selected Assemblies Catalogue #999-901-192
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-60 GPM
V1
Cavity T-17A
V2
2.25
1.12
C1
0
C2
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1” NPTF
CKGB-XCN-YJE
1 1/4” NPTF
CKGB-XCN-YJF
SAE-12
CKGB-XCN-YJL
SAE-16
CKGB-XCN-YJM
Mounting Holes:
.42 diameter through hole,
2 places.
L Control
0
2.00
C1
4.50
C2
5.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
V2
6.50
0
.75
2.09
0-120 GPM
V1
V2
2.37 Max.
V1
.75
4.00
Cavity T-19A
4.50
2.25
C1
0
C2
Mounting Holes: (opposite side)
.375-16 UNC-2B
x .62 deep. 4 places.
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1 1/2” SAE C62
CKIB-XCN-YM6
0
.52
V1
2.78 Max.
C1
2.53
L Control
C2
6.50
V2
8.52
9.03
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
2.41
4.94
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
87
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(INLINE CROSS-PILOTED BODIES, 2 CAVITIES)
PILOT OPERATED
ASSEMBLIES
V1
C1
V2
Go to www.sunhydraulics.com
for more product information and pricing.
0-15 GPM
Cavity T-11A
Mounting Holes:
.34 diameter through hole
.88 diameter socket clearance.
2 places.
C2
L Control
1.81 Max.
Ports
C1, C2, V1 & V2
Assembly
Model Code*
3/8” NPTF
CKCB-XCN-XEB
2.05
SAE-6
CKCB-XCN-XEI
1.28
SAE-8
CKCB-XCN-XEJ
2.64
V1
V2
1.28
0
C2
V2
.66
0
0
0 .29
2.94 2.31 1.47 .62 0
3.10 3.38
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
V1
C1
V2
0-30 GPM
Cavity T-2A
Mounting Holes:
.34 diameter through hole
.88 diameter socket clearance.
2 places.
C2
L Control
2.09 Max.
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1/2” NPTF
CKEB-XCN-XAC
2.56
CKEB-XCN-XAD
1.66
3/4” NPTF
SAE-6
CKEB-XCN-XAI
SAE-8
CKEB-XCN-XAJ
3.22
V1
V2
V2
.88
0
3.62 2.84 1.81 .78 0
1.66
C2
0
0
0 .28
3.59 3.88
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
88
US Selected Assemblies Catalogue #999-901-192
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(DIRECT MOUNT .75”/1.00”/1.25” SAE C61 FLANGE PORT/GASKET MOUNT BODIES,
THROUGH PILOT PORT)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-30 GPM
3
3
2
1
Cavity T-2A
2.50
1.25
0
Ports
1 and 2
Port 3
Assembly
Model Code*
3/4” SAE C61
SAE-6
CKEB-XCN-ZNV
.75 SAE Code 61 4-Bolt
Flange Pattern, 2 places.
X Control
2 holes tapped, 4 holes through .50 Max.
0
2
3
1.25
1
2.25
0
1.03
1.91
0-60 GPM
3
3
2
1
2.84 3.50
-214 O-ring
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
Cavity T-17A
3.00
1.50
Ports
1 and 2
Port 3
Assembly
Model Code*
1” SAE C61
SAE-6
CKGB-XCN-ZNW
0
1.00 SAE Code 61 4-Bolt
Flange Pattern, 2 places.
X Control
2 holes tapped, 4 holes through .87 Max
0
2
1.13
3
1
2.94
0
1.16 2.19
-219 O-ring
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0-120 GPM
3
3
2
1
3.50 4.13
Cavity T-19A
3.50
1.75
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1 1/4” SAE C61
SAE-6
CKIB-XCN-ZNX
1.25” SAE Code 61 4-Bolt Flange Pattern,
2 places. Port 1 through hole. X Control
Port 2 tapped hole.
1.13 Max.
0
2
3
1.72
1
3.44
0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
1.44
2.62
-222 O-ring
4.81 5.50
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
US Selected Assemblies Catalogue #999-901-192
89
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(DIRECT MOUNT .75”/1.00”/1.25” C62 FLANGE PORT/GASKET MOUNT BODIES,
THROUGH PILOT/DRAIN PORT)
PILOT OPERATED
ASSEMBLIES
Go to www.sunhydraulics.com
for more product information and pricing.
0-30 GPM
3
3
2
1
Cavity T-2A
3.00
1.50
Ports
1 and 2
Port 3
Assembly
Model Code*
3/4” SAE C62
SAE-6
CKEB-XCN-ZDS
0
.75” SAE Code 62 4-Bolt Flange Pattern,
2 places. Port 1 through hole.
Port 2 tapped hole.
L Control
0
2.09 Max.
2
1.22
3
1
2.44
1.19
0
2.12
0-60 GPM
3
3
2
1
3.03 3.53
-214 O-ring
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
Cavity T-17A
3.50
1.75
Ports
1 and 2
Port 3
Assembly
Model Code*
1” SAE C62
SAE-6
CKGB-XCN-ZDR
0
1.00” SAE Code 62 4-Bolt Flange Pattern,
2 places. Port 1 through hole.
Port 2 tapped hole.
0
L Control
2.34 Max.
2
3
1.72
1
3.44
0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
1.38 2.47
-219 O-ring
0-120 GPM
3
3
2
1
3.69 4.31
Cavity T-19A
4.00
2.00
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1 1/4” SAE C62
SAE-6
CKIB-XCN-ZFD
1.25” SAE Code 62 4-Bolt Flange Pattern,
2 places. Port 1 through hole.
Port 2 tapped hole.
0
L Control
2.75 Max.
2
1.97
3
1
3.94
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0
1.53
2.78
4.88 5.62
-222 O-ring
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
90
US Selected Assemblies Catalogue #999-901-192
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(GASKET MOUNT BODIES)
PILOT OPERATED
ASSEMBLIES
V2
Go to www.sunhydraulics.com
for more product information and pricing.
0-15 GPM
V1
Cavity T-11A
0
.59
C1
1.19
C2
-113 O-ring
Mounting Holes: .34 diameter through hole,
counterbore .50 diameter
x .25 deep. 2 places.
Ports
C1, C2, V1 & V2
Assembly
Model Code*
3/8” NPTF
CKCB-XCN-ZTN
2.50
CKCB-XCN-ZTC
2.00
SAE-6
L Control
1.81 Max.
V1
1.63
1.03
.81
.50
.31
0
V2
C2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
V2
C1
0
3.75
1.00
0-30 GPM
V1
Cavity T-2A
0
.72
C1
1.44
-117 O-ring
C2
Ports
C1, C2, V1 & V2
Assembly
Model Code*
1/2” NPTF
CKEB-XCN-ZTF
SAE-8
CKEB-XCN-ZTG
Mounting Holes: .42 diameter
through hole, 2 places.
3.00
L Control
1.63 Max.
V1
2.38
1.94
1.22
.94
.63
.34
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
V2
V2
0
C1
C2
1.22
4.25
0-60 GPM
V1
Cavity T-17A
0
1.09
C1
2.19
C2
Ports
C1, C2, V1 & V2
Assembly
Model Code*
3/4” NPTF
CKGB-XCN-ZTJ
SAE-12
CKGB-XCN-ZTK
-121 O-ring
Mounting Holes: .53 diameter through hole,
counterbore .78 diameter
L Control
x .44 deep. 2 places.
4.00
2.22 Max.
V1
3.25
2.69
1.56
C1
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
C2
V2
1.06
.44
0
0
5.47
1.44
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, a7nd options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
91
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
THREE PORT PILOT-TO-OPEN CHECK APPLICATIONS
(GASKET MOUNT BODIES, 2 CAVITIES)
PILOT OPERATED
ASSEMBLIES
V1
Go to www.sunhydraulics.com
for more product information and pricing.
0-15 GPM
V2
Cavity T-11A
0
C2
2.12 Max.
1.69
C1
C2
2.19
-113 O-ring
Ports
C2, V1 & V2
Assembly
Model Code*
3/8” NPTF
SAE-6
CKCB-XCN-YVM
CKCB-XCN-YVY
Mounting Holes: (opposite side)
.34 diameter through hole, counterbore .50 diameter
x .25 deep. 2 places.
L Control
2.50
2.12 Max.
V1
2.00
1.62
C1
V2
1.03
.78
.31
C2
0
*Add modifier /S to order SG Iron for pressure rating
over .
V1
0
1.00
0-30 GPM
V2
3.75
Cavity T-2A
0
.81
1.75
Max.
C1
C2
2.75
-117 O-ring
Ports
C2, V1 & V2
Assembly
Model Code*
1/2” NPTF
SAE-8
CKEB-XCN-YVW
CKEB-XCN-YVV
Mounting Holes: .41 diameter through hole,
2 places.
L Control
1.75 Max.
3.00
V1
2.38
1.94
V2
C1
C2
1.22
1.00
.34
*Add modifier /S to order SG Iron for pressure rating
over .
V1
0
0
1.22
0-60 GPM
V2
4.25
Cavity T-17A
0
2.22
Max.
C1
C2
Ports
C2, V1 & V2
Assembly
Model Code*
3/4” NPTF
SAE-12
CKEB-XCN-YVT
CKEB-XCN-YVS
-121 O-ring
Mounting Holes: (opposite side)
.53 diameter through hole,
counterbore .78 diameter
x .44 deep. 2 places.
4.00
L Control
2.22 Max.
V1
2.69
C2
V2 C1
*Add modifier /S to order SG Iron for pressure rating
over .
1.56
.44
0
0
1.44
NOTES: Page 78 for cartridge model CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
92
US Selected Assemblies Catalogue #999-901-192
Four Port Pilot-to-Open Check Assemblies
Cartridge Type
2
Page
3
Vented, 4 Port Cavity
94
4
1
Line Mounted Assemblies
(Body Type)
2
3
90 Degree
96
90 Degree with Gauge Port
97
2.00” SAE C62 Flange Port, 2 Cavities
98
90 Degree Cross-Piloted, 2 Cavities, Common Port 4
99
4
1
2
3
G
4
1
2
3
4
1
2A
2B
4
1A
1B
US Selected Assemblies Catalogue #999-901-192
93
FOUR PORT
PILOT-TO-OPEN CHECK
Pilot-to-Open Check Valves
VENTED, 4 PORT CAVITY
2
3
Capacity
4
1
Typical
Cartridge
Model Code
Cavity
Cartridge Dimensions
c
b
X
a
L
Installation
Torque
(lb. ft.)
30/35
15 GPM
CVCV – XCN
T - 21A
1.38
7/8”
2.11
2.34
30 GPM
CVEV – XCN
T - 22A
1.38
1 1/8”
2.34
2.56
45/50
60 GPM
CVGV – XCN
T - 23A
1.81
1 1/4”
2.81
3.03
150/160
120 GPM
CVIV – XCN
T - 24A
2.50
1 5/8”
3.50
3.77
350/375
OPTION ORDERING INFORMATION
CV ✱ V – ✱ ✱ ✱
Full Adjustment 5 Turns
+
-
L Control
X Control
Nominal
Capacity
b
c
4
Vent
Cracking Pressure
Seal
C 15 GPM
X Standard Pilot
A 4 psi
N Buna-N
E 30 GPM
L Manual Load
Release
B 15 psi
V Viton
G 60 GPM
I
3
Pilot
Control**
C 30 psi
D 50 psi
120 GPM
Locating
Shoulder
E 75 psi
F 100 psi
2
Valve
Load 1
a
** See page 244 for information
on Control Options
94
US Selected Assemblies Catalogue #999-901-192
FOUR PORT
PILOT-TO-OPEN CHECK
TECHNICAL TIPS / PERFORMANCE CURVES
Pilot-to-Open Check Valves, Vented
Performance Curves
Typical Pressure Drop
CVCV-X*N
P = psi
400
300
200
XEN
100
XCN
0
5
OT
PIL
LL
FU
10
15
20
Flow = GPM
CVEV-X*N
P = psi
400
300
200
XEN
100
XCN
0
7.5
OT
PIL
LL
FU
15
22.5
30
Flow = GPM
CVGV-X*N
P = psi
400
300
200
XEN
100
XCN
0
20
OT
PIL
LL
FU
40
60
Flow = GPM
80
CVIV-X*N
400
P = psi
Applications
Sun pilot-to-open check valves are
non-modulating, on/off valves used for load locking
only, therefore do not provide smooth motion control.
They allow free flow through check valve from port 2
to port 1, then block reverse flow until a pilot pressure
directly proportional to the load pressure is sensed at
port 3 so that a pilot piston can push the check poppet
off of its seat.
Because of the on/off action of the pilot-to-open
check valve it makes them unsuitable for use with
overrunning loads that will cause a loss of pilot
pressure. Without pilot pressure the check valve will
close until adequate pilot pressure is again restored,
causing a ratcheting motion.
Pilot-to-open check valves should never be used
with paired cylinders. Pilot pressure will open the
valve with the least load first, transferring the
combined load to the second valve at double the
pressure.
The vented type is used on applications where there
is variable back-pressure downstream of the valve
which could cause instability in a standard valve. The
pilot spring chamber is vented externally to tank
through a fourth port making it insensitive to back
pressure. Any pressure generated on the drain port
will be additive to the pilot pressure required.
NOTE: The vent port should never be plugged, as
seal weepage will eventually cause valves to
malfuntion.
It is preferable that the pilot-to-open check valve is
mounted as close as possible to the actuator to provide
maximum protection in the event of a hydraulic line
failure. This can be achieved by incorporating them
directly into the actuator, or, Sun offers a range of
gasket mounted bodies that bolt directly onto the
mounting face of a cylinder or motor.
Design Concepts and Features
■
Pilot-to-open check valves have a pilot ratio of 3:1,
which is suitable for most applications.
■
Operating pressures up to 5000 psi. Flow
capacities up to 120 GPM
■ Low leakage when closed, less than 1 drop/min.
This leakage figure is checked at both low and high
pressure during test.
■ Optional free flow check springs available, from
4 psi to avoid cavitation up to 100 psi for severe
applications.
■
These cartridges have a sealed pilot piston.
■
Valve with emergency manual release screw
available, in case pilot pressure is not available.
■
Hardened poppet and seat provides long life and
better resistance to contamination.
300
200
XEN
100
XCN
0
40
OT
PIL
LL
FU
80
120
160
Flow = GPM
General Application Requirements
■
■
■
■
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at cracking flow.
US Selected Assemblies Catalogue #999-901-192
95
FOUR PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
FOUR PORT PILOT-TO-OPEN CHECK APPLICATIONS
(90 DEGREE BODIES)
Go to www.sunhydraulics.com
for more product information and pricing.
VENTED
0-15 GPM
2
Cavity T-21A
3
4
1.25
.62
1
0
Ports
1 and 2
Ports
3 and 4
Assembly
Model Code*
1/4” NPTF
3: 1/4” NPTF
4: 1/4” NPTF
CVCV-XCN-MAA
3/8” NPTF
3: 3/8” NPTF
4: 1/4” NPTF
CVCV-XCN-MAB
1/2” NPTF
3: 3/8” NPTF
4: 1/4” NPTF
CVCV-XCN-MAC
SAE-6
3: SAE-6
4: SAE-6
CVCV-XCN-MAI
SAE-8
3: SAE-8
4: SAE-6
CVCV-XCN-MAJ
SAE-10
3: SAE-8
4: SAE-6
CVCV-XCN-MAK
0
.38
Mounting Holes:
.34 diameter through hole
2 places.
1.09
Max.
4
2
1
1.25
L Control
3
2.50
0
.44
1.59
2.56 3.12 3.56
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
2
3
0-30 GPM
Cavity T-22A
1.50
4
1
.75
0
Ports
1 and 2
Ports
3 and 4
Assembly
Model Code*
3/8” NPTF
3: 3/8” NPTF
4: 1/4” NPTF
CVEV-XCN-NAB
1/2” NPTF
3: 1/2” NPTF
4: 1/4” NPTF
CVEV-XCN-NAC
3/4” NPTF
3: 1/2” NPTF
4: 1/4” NPTF
CVEV-XCN-NAD
SAE-8
3: SAE-8
4: SAE-6
CVEV-XCN-NAJ
SAE-10
3: SAE-10
4: SAE-6
CVEV-XCN-NAK
0
Mounting Holes:
.42 diameter through hole
2 places.
2
.50
1.50
4
1.25
Max.
1
3
L Control
3.00
0 .44
1.72
2.69 3.31 3.75
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 94 for cartridge model CV*V-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
96
US Selected Assemblies Catalogue #999-901-192
FOUR PORT PILOT-TO-OPEN CHECK APPLICATIONS
(90 DEGREE BODIES)
Go to www.sunhydraulics.com
for more product information and pricing.
VENTED
2
3
G
4
0-60 GPM
Cavity T-23A
2.25
1.13
1
0
Ports
1 and 2
Ports
3 and 4
Assembly
Model Code*
3/4” NPTF
3: 3/4” NPTF
4: 1/4” NPTF
CVGV-XCN-PCD
1” NPTF
3: 3/4” NPTF
4: 1/4” NPTF
CVGV-XCN-PCE
1 1/4” NPTF
3: 3/4” NPTF
4: 1/4” NPTF
CVGV-XCN-PCF
3: SAE-12
4: SAE-6
CVGV-XCN-PCL
3: SAE-12
4: SAE-6
CVGV-XCN-PCM
SAE-12
SAE-16
0
Mounting Holes:
.42 diameter through hole, 2 places.
2
.75
2.00
1.41
Max.
4
1
L Control
3
G
4.00
0
1.09
2.12
3.41 4.25 4.75
1/4” NPTF Gauge Port
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
2
3
0-120 GPM
Cavity T-24A
3.00
G
4
1
Ports
1 and 2
1” NPTF
1 1/4” NPTF
SAE-16
SAE-20
0
Ports
3 and 4
Assembly
Model Code*
3: 1” NPTF
4: 1/4” NPTF
3: 1/4” NPTF
4: 1/4” NPTF
3: SAE-16
4: SAE-6
CVIV-XCN-QAE
3: SAE-16
4: SAE-6
1.50
CVIV-XCN-QAF
Mounting Holes:
.42 diameter through hole, 2 places.
0
.50
4
2
2.50
1.69 Max.
1
CVIV-XCN-QAM
G
CVIV-XCN-QAN
L Control
5.00
0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
3
1.06
2.50
4.28 5.31 5.88
1/4” NPTF Gauge Port
NOTES: Page 94 for cartridge model CV*V-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
97
FOUR PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
FOUR PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
FOUR PORT PILOT-TO-OPEN CHECK APPLICATIONS
(2.00” SAE C62 FLANGE PORT BODY, 2 CAVITIES)
Go to www.sunhydraulics.com
for more product information and pricing.
VENTED
0-240 GPM
2
Cavity T-24A
3
0
2.26
7.78
0
0
1.06
4
2.97
1
1
4.88
Ports
1 and 2
Ports
3 and 4
Assembly
Model Code*
2” SAE C62
3: SAE-6
4: SAE-6
CVIV-XCN-Z9T
5.94
0
6.75
Mounting Holes:
L Control
.500-13 UNC-2B x (.87) DP.
0
4.97
8.34 1.69
Max.
0
2.97
2
3
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
4
5.94
NOTES: Page 94 for cartridge model CV*V-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
98
US Selected Assemblies Catalogue #999-901-192
FOUR PORT PILOT-TO-OPEN CHECK APPLICATIONS
(90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES, COMMON PORT 4)
Go to www.sunhydraulics.com
for more product information and pricing.
VENTED
2A
0-15 GPM
2B
Cavity T-21A
1.25
.62
4
1A
0
Mounting Holes:
.34 diameter through holes, places.
1B
Ports
1B, 2A & 2B
Port 4
Assembly
Model Code*
1/4” NPTF
1/4” NPTF
CVCV-XCN-XPA
3/8” NPTF
1/4” NPTF
CVCV-XCN-XPB
1/2” NPTF
1/4” NPTF
CVCV-XCN-XPC
SAE-6
SAE-6
CVCV-XCN-XPI
SAE-8
SAE-6
CVCV-XCN-XPJ
SAE-10
SAE-6
CVCV-XCN-XPK
0
.38
1.09 Max.
2B
1.25
1B
2.75
1A
L Control
2A
3.62
4.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
2A
0 .50
1.59
0-30 GPM
2B
4
3.12 3.56
Cavity T-22A
2.00
1.00
4
1A
0
Mounting Holes:
.42 diameter through hole, 2 places.
1B
Ports
1B, 2A & 2B
Port 4
Assembly
Model Code*
3/8” NPTF
1/4” NPTF
CVEV-XCN-XIB
1/2” NPTF
1/4” NPTF
CVEV-XCN-XIC
3/4” NPTF
1/4” NPTF
CVEV-XCN-XID
SAE-6
SAE-6
CVEV-XCN-XII
SAE-8
SAE-6
CVEV-XCN-XIJ
0
.75
2B
1.62
1B
3.38
1A
2A
4.25
4
1.25 Max.
L Control
5.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0 .50
1.72
3.31 4.00
NOTES: Page 94 for cartridge model CV*V-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
US Selected Assemblies Catalogue #999-901-192
99
FOUR PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
FOUR PORT
PILOT-TO-OPEN CHECK
Line Mounted Assemblies
FOUR PORT PILOT-TO-OPEN CHECK APPLICATIONS
(90 DEGREE CROSS-PILOTED BODIES, 2 CAVITIES, COMMON PORT 4)
Go to www.sunhydraulics.com
for more product information and pricing.
VENTED
2A
0-60 GPM
2B
Cavity T-23A
2.50
1.25
4
1A
0
Mounting Holes:
.42 diameter through hole, 2 places.
1B
0
Ports 1A
1B, 2A & 2B
Port 4
Assembly
Model Code*
.75
3/4” NPTF
1/4” NPTF
CVGV-XCN-XMD
2.00
1” NPTF
1/4” NPTF
CVGV-XCN-XME
1 1/4” NPTF
1/4” NPTF
CVGV-XCN-XMF
SAE-12
1/4” NPTF
CVGV-XCN-XML
SAE-16
1/4” NPTF
CVGV-XCN-XMM
1.41 Max.
2B
4
1B
L Control
4.50
1A
2A
5.75
6.50
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
2A
0 .75
2.38
0-120 GPM
2B
4.48 5.00
Cavity T-24A
3.00
1.50
4
1A
Ports 1A
1B, 2A & 2B
0
Mounting Holes:
.42 diameter through hole, 2 places.
1B
Port 4
Assembly
Model Code*
1” NPTF
1/4” NPTF
CVIV-XCN-XLE
1 1/4” NPTF
1/4” NPTF
CVIV-XCN-XLF
0
.62
2.12
1.69 Max.
2B
1B
L Control
4.88
1A
2A
6.38
7.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
4
0 .62
2.62
5.44 6.00
NOTES: Page 94 for cartridge model CV*V-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
100
US Selected Assemblies Catalogue #999-901-192
Check Assemblies
Cartridge Type
Page
2
1 to 2 Free Flow
102
2 to 1 Free Flow
102
1
2
1
Line Mounted Assemblies
(Body Type)
2
90 Degree
104
90 Degree with Gauge Port
105
Inline
Inline/Inline 1.50”/2.00” SAE C61 Flange Port
2.00” SAE C61/C62 Flange Port, 2 Port Cavity in Parallel
106
107
108
1
2
G
1
2
1
US Selected Assemblies Catalogue #999-901-192
101
CHECK
Check Valves
1 TO 2 FREE FLOW
1
Cartridge Dimensions
c
a
b
X
10 GPM
CXBA – XCN
T - 162A
1.22
3/4”
.82
Installation
Torque
(lb. ft.)
25/30
20 GPM
CXDA – XCN
T - 13A
1.38
7/8”
.75
30/35
40 GPM
CXFA – XCN
T - 5A
1.62
1 1/8”
.69
45/50
80 GPM
CXHA – XCN
T - 16A
2.44
1 1/4”
.97
150/160
160 GPM
CXJA – XCN
T - 18A
3.13
1 5/8”
1.19
350/375
Capacity
2
Typical
Cartridge
Model Code
Cavity
OPTION ORDERING INFORMATION
CX ✱ A – ✱ ✱ ✱
b
Nominal
Capacity
c
Locating
Shoulder
a
B 10 GPM
Control**
X Non-adjustable
Cracking Pressure
Seal
A 4 psi
N Buna-N
V Viton
D 20 GPM
B 15 psi
F 40 GPM
C 30 psi
H 80 GPM
D 50 psi
J 160 GPM
E 75 psi
F 100 psi
2
Out
In 1
** See page 244 for information
on Control Options
2 TO 1 FREE FLOW
2
1
Capacity
7.5 GPM
CXAD – XCN
T - 162A
1.22
3/4”
.82
Installation
Torque
(lb. ft.)
25/30
15 GPM
CXCD – XCN
T - 13A
1.38
7/8”
.75
30/35
CXED – XCN
T - 5A
1.62
1 1/8”
.69
45/50
60 GPM
CXGD – XCN
T - 16A
2.44
1 1/4”
.97
150/160
120 GPM
CXID – XCN
T - 18A
3.13
1 5/8”
1.19
350/375
Nominal
Capacity
c
A* 7.5 GPM
Locating
Shoulder C 15 GPM
a
Cavity
30 GPM
OPTION ORDERING INFORMATION
b
CX ✱ D – ✱ ✱ ✱
Control**
X Non-adjustable
Cracking Pressure
A 4 psi
N Buna-N
V Viton
C 30 psi
G 60 GPM
D 50 psi
I
E 75 psi
120 GPM
Seal
B 15 psi
E 30 GPM
F 100 psi
2
In
Out 1
Cartridge Dimensions
c
a
b
X
Typical
Cartridge
Model Code
** See page 244 for information
on Control Options
102
*CXAD available with
A,C,E Cracking Pressures
Only.
US Selected Assemblies Catalogue #999-901-192
TECHNICAL TIPS / PERFORMANCE CURVES
Check Valves, Free Flow, Port 1 to 2
CHECK
Performance Curves
Typical Pressure Rise
CXBA-X*N
CXDA-X*N
200
200
100
XEN
50
150
P = psi
P = psi
150
XCN
100
XEN
50
XCN
XAN
0
2.5
CXFA-X*N
XAN
5
7.5
10
Flow = GPM
0
5
CXHA-X*N
10
15
Flow = GPM
20
200
200
150
100
P = psi
P = psi
Applications
Check valves are used to provide free flow in one
direction and blocked flow in the opposite direction.
The preferred check CX*A-X*N (free flow 1 to 2)
should be used wherever possible.
Design Concepts and Features
■
Hardened and lapped sealing surfaces provide low
leakage (less than 1 drop / min.) and long life.
■
Extensive range of spring options.
■
Available in five frame sizes with operating
pressures to 5000 psi.
XEN
50
150
100
XCN
XAN
0
10
CXJA-X*N
XEN
50
XCN
XAN
20
30
40
100
150
200
Flow = GPM
0
25
50
75
Flow = GPM
100
P = psi
200
150
100
XEN
50
XCN
XAN
0
50
Flow = GPM
Check Valves, Free Flow, Port 2 to 1
Performance Curves
Typical Pressure Rise
CXAD-X*N
CXCD-X*N
200
300
150
100
P = psi
P = psi
Applications
The CX*D-X*N non-preferred check (free flow 2 to
1) should only be used to simplify complex manifold
designs.
Design Concepts and Features
■ Hardened and lapped sealing surfaces provide low
leakage (less than 1 drop / min.) and long life.
■
Extensive range of spring options.
■
Available in five frame sizes with operating
pressures to 5000 psi.
XEN
50
XCN
200
XEN
100
XCN
XAN
0
2.5
XAN
5
7.5
10
0
5
Flow = GPM
CXED-X*N
P = psi
P = psi
200
XEN
100
0
200
XEN
100
XCN
XAN
XAN
7.5
CXID-X*N
15
22.5
80
120
Flow = GPM
30
0
P = psi
300
200
XEN
100
XCN
XAN
0
40
160
Flow = GPM
General Application Requirements
■
■
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at a crack flow rate.
US Selected Assemblies Catalogue #999-901-192
103
20
300
XCN
■
15
CXGD-X*N
300
■
10
Flow = GPM
20
40
60
Flow = GPM
80
CHECK
Line Mounted Assemblies
TWO PORT FLOW CONTROL APPLICATIONS
(90 DEGREE BODIES)
FREE FLOW
Port 1 to Port 2
FREE FLOW
Port 2 to Port 1
Go to www.sunhydraulics.com
for more product information and pricing.
0-10 GPM
2
Cavity T-162A
0-8 GPM
2
1.00
.50
0
1
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
CXBA-X*N-AAA
3/8” NPTF
CXBA-X*N-AAB
SAE-4
CXBA-X*N-AAH
SAE-6
CXBA-X*N-AAI
1
0
.50
X Control
.79 Max.
2
1/4” NPTF
CXAD-X*N-AAA
3/8” NPTF
CXAD-X*N-AAB
SAE-4
CXAD-X*N-AAH
SAE-6
CXAD-X*N-AAI
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.50
0
0-20 GPM
28
1 33
2 00
Cavity T-13A
0-16 GPM
1.25
2
Assembly
Model Code*
1
1.22
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Ports
1 and 2
Mounting Hole:
.28 diameter through hole
2
.62
1
1
0
Ports
1 and 2
Assembly
Model Code*
Mounting Hole:
.34 diameter through hole
1/4” NPTF
CXDA-X*N-GAA
0
3/8” NPTF
CXDA-X*N-GAB
.28
SAE-4
CXDA-X*N-GAH
SAE-6
CXDA-X*N-GAI
SAE-8
CXDA-X*N-GAJ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.00
Ports
1 and 2
X Control
.72 Max.
2
1
1/4” NPTF
CXCD-X*N-GAA
3/8” NPTF
CXCD-X*N-GAB
SAE-4
CXCD-X*N-GAH
SAE-6
CXCD-X*N-GAI
SAE-8
CXCD-X*N-GAJ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.62
0-40 GPM
Cavity T-5A
0-31 GPM
1.50
2
Assembly
Model Code*
2
.75
1
1
0
Ports
1 and 2
Assembly
Model Code*
3/8” NPTF
CXFA-X*N-DAB
0
1/2” NPTF
CXFA-X*N-DAC
.38
SAE-6
CXFA-X*N-DAJ
SAE-6
CXED-X*N-DAJ
SAE-8
CXFA-X*N-DAK
SAE-8
CXED-X*N-DAK
Mounting Hole:
.42 diameter through hole
1.25
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2
X Control
.63 Max.
Ports
1 and 2
Assembly
Model Code*
3/8” NPTF
CXED-X*N-DAB
1/2” NPTF
CXED-X*N-DAC
1
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.00
NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
104
US Selected Assemblies Catalogue #999-901-192
Line Mounted Assemblies
CHECK
TWO PORT FLOW CONTROL APPLICATIONS
(90 DEGREE BODIES)
FREE FLOW
Port 1 to Port 2
FREE FLOW
Port 2 to Port 1
Go to www.sunhydraulics.com
for more product information and pricing.
0-80 GPM
2
Cavity T-16A
0-60 GPM
2
2.25
1.12
G
G
0
1
1
1/4” NPTF Gauge Port
Mounting Hole:
.42 diameter through hole
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
CXHA-X*N-IAD
1” NPTF
CXHA-X*N-IAE
1 1/4” NPTF
CXHA-X*N-IAF
SAE-12
CXHA-X*N-IAL
SAE-16
CXHA-X*N-IAM
X Control
.91 Max.
0
2
1.50
1
1.88
G
3.00
1.00
0
2.62
Assembly
Model Code*
3/4” NPTF
CXGD-X*N-IAD
1” NPTF
CXGD-X*N-IAE
1 1/4” NPTF
CXGD-X*N-IAF
SAE-12
CXGD-X*N-IAL
SAE-16
CXGD-X*N-IAM
4.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0-160 GPM
2
Ports
1 and 2
Cavity T-18A
0-120 GPM
2
2.75
1.38
G
G
0
1
Mounting Hole:
.42 diameter through hole
Ports
1 and 2
1
1/4” NPTF Gauge Port
Assembly
Model Code*
0
X Control
1.13 Max.
2
.62
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
CXJA-X*N-LAD
3/4” NPTF
CXID-X*N-LAD
1” NPTF
CXJA-X*N-LAE
1” NPTF
CXID-X*N-LAE
1 1/4” NPTF
CXJA-X*N-LAF
SAE-12
CXJA-X*N-LAL
SAE-16
CXJA-X*N-LAM
1
2.12
G
3.50
0
2.81
1.09
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
4.62
1 1/4” NPTF
CXID-X*N-LAF
SAE-12
CXID-X*N-LAL
SAE-16
CXID-X*N-LAM
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
105
CHECK
Line Mounted Assemblies
TWO PORT FLOW CONTROL APPLICATIONS
(INLINE BODIES)
FREE FLOW
Port 1 to Port 2
FREE FLOW
Port 2 to Port 1
Go to www.sunhydraulics.com
for more product information and pricing.
0-10 GPM
Cavity T-162A
0-8 GPM
2
2
X Control
.57 Max.
2.00
1
1
1.12
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
CXBA-X*N-ACA
.56
3/8” NPTF
CXBA-X*N-ACB
SAE-4
CXBA-X*N-ACH
.25
0 0
SAE-6
CXBA-X*N-ACI
1.00
.50
0
Ports
1 and 2
2
1
2.56
1.28
0
Assembly
Model Code*
1/4” NPTF
CXAD-X*N-ACA
3/8” NPTF
CXAD-X*N-ACB
SAE-4
CXAD-X*N-ACH
SAE-6
CXAD-X*N-ACI
Mounting Holes:
.28 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0-20 GPM
Cavity T-13A
0-16 GPM
2
2
X Control
.72 Max.
2.00
1
1
1.52
1.13
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
CXDA-X*N-GCA
.56
3/8” NPTF
CXDA-X*N-GCB
.25
0 0
SAE-6
CXDA-X*N-GCI
SAE-8
CXDA-X*N-GCJ
1.19
.59
0
Ports
1 and 2
2
1
0
1.28
2.56
Mounting Holes:
.34 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Assembly
Model Code*
1/4” NPTF
CXCD-X*N-GCA
3/8” NPTF
CXCD-X*N-GCB
SAE-6
CXCD-X*N-GCI
SAE-8
CXCD-X*N-GCJ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0-40 GPM
Cavity T-5A
0-31 GPM
2
2
X Control
.66 Max.
2.38
1.75
1
Ports
1 and 2
Assembly
Model Code*
3/8” NPTF
CXFA-X*N-DCB
1/2” NPTF
CXFA-X*N-DCC
SAE-6
CXFA-X*N-DCI
SAE-8
CXFA-X*N-DCJ
SAE-10
CXFA-X*N-DCK
1
1.25
Ports
1 and 2
2
.63
1
.31
0 0
1.50
.75
0
0
1.63
Mounting Holes:
.42 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3.25
Assembly
Model Code*
3/8” NPTF
CXED-X*N-DCB
1/2” NPTF
CXED-X*N-DCC
SAE-6
CXED-X*N-DCI
SAE-8
CXED-X*N-DCJ
SAE-10
CXED-X*N-DCK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
106
US Selected Assemblies Catalogue #999-901-192
Line Mounted Assemblies
CHECK
TWO PORT FLOW CONTROL APPLICATIONS
(INLINE/INLINE 1.50”/2.00” SAE C61 FLANGE PORT BODIES)
FREE FLOW
Port 1 to Port 2
FREE FLOW
Port 2 to Port 1
Go to www.sunhydraulics.com
for more product information and pricing.
0-80 GPM
Cavity T-16A
0-60 GPM
2
2
X Control
.92 Max.
3.88
1
1
3.00
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
CXHA-X*N-ICD
1” NPTF
CXHA-X*N-ICE
1 1/4” NPTF
CXHA-X*N-ICF
SAE-12
CXHA-X*N-ICL
SAE-16
CXHA-X*N-ICM
2.31
Ports
1 and 2
1.16
1
2
.50
0
2.25
1.12
0
0
2.31
4.62
Mounting Holes:
.53 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Assembly
Model Code*
3/4” NPTF
CXGD-X*N-ICD
1” NPTF
CXGD-X*N-ICE
1 1/4” NPTF
CXGD-X*N-ICF
SAE-12
CXGD-X*N-ICL
SAE-16
CXGD-X*N-ICM
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0-160 GPM
Cavity T-18A
2
0-120 GPM
2
X Control
.66 Max.
6.25
5.00
1
1
4.00
Ports
1 and 2
Assembly
Model Code*
1 1/2” SAE C61
CXJA-X*N-ZLS
2
2.00
1.50
0
3.75
1.88
1
Ports
1 and 2
Assembly
Model Code*
1 1/2” SAE C61
CXID-X*N-ZLS
0
0
0
2.50
5.00
Mounting Holes:
.53 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0-160 GPM
Cavity T-18A
2
0-120 GPM
2
X Control
.66 Max.
6.25
5.00
1
1
4.00
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
CXJA-X*N-ZLR
2
1
2.00
1.50
0
4.12
2.06
0
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
CXID-X*N-ZLR
0
0
2.50
5.00
Mounting Holes:
.53 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
107
CHECK
Line Mounted Assemblies
TWO PORT FLOW CONTROL APPLICATIONS
(2.00” SAE C61/C62 FLANGE PORT BODIES, 2 PORT CAVITY IN PARALLEL)
FREE FLOW
Port 1 to Port 2
FREE FLOW
Port 2 to Port 1
Go to www.sunhydraulics.com
for more product information and pricing.
0-320 GPM
Cavity T-18A
0-240 GPM
4.94
2
2
2.47
1
1
0
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
CXJA-X*N-XZY
Mounting Holes:
.375-16 UNC-2B x .62 deep.
2 places.
0
X Control
.91 Max.
.94
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
CXID-X*N-XZY
2.47
4.00
4.94
0
2.03
4.66
6.56
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0-320 GPM
Cavity T-18A
0-240 GPM
5.94
2
2
2
2.97
1
1
0
Mounting Holes:
.375-16 UNC x .75 deep. 2 places.
Ports
1 and 2
Assembly
Model Code*
2” SAE C62
CXJA-X*N-VTN
0
.63 Max.
1.06
Ports
1 and 2
Assembly
Model Code*
2” SAE C62
CXID-X*N-VTN
1
2.97
X Control
4.88
5.94
0
2.28
4.88
7.12
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
108
US Selected Assemblies Catalogue #999-901-192
Needle Assemblies
Cartridge Type
Page
2
Fully Adjustable Needle
110
Fully Adjustable Needle with Reverse Free Flow Check
110
1
2
1
Line Mounted Assemblies
(Body Type)
2
2
1
90 Degree
112
90 Degree with Gauge Port
113
Inline
Inline/Inline 1.50”/2.00” SAE C61 Flange Port
2.00” SAE C61/C62 Flange Port, 2 Port Cavity in Parallel
114
115
116
1
2
G
1
2
1
US Selected Assemblies Catalogue #999-901-192
109
NEEDLE / RESTRICTOR
Needle Valves
FULLY ADJUSTABLE NEEDLE
2
Cartridge Dimensions
c
b
L
H
Capacity
Typical
Cartridge
Model Code
.16 in
NFBC – LCN
T - 162A
1.22
3/4”
1.59
-
1.73
Installation
Torque
(lb. ft.)
25/30
.19 in
NFCC – LCN
T - 13A
1.38
7/8”
2.06
2.44
2.31
30/35
1
Cavity
a
K
.25 in.
NFDC – LAN
T - 5A
1.38
1 1/8”
2.44
2.82
2.73
45/50
.38 in.
NFEC – LEN
T - 16A
1.81
1 1/4”
2.66
3.06
2.91
150/160
.56 in.
NFFC – LGN
T - 18A
2.50
1 5/8”
3.31
3.50
3.47
350/375
OPTION ORDERING INFORMATION
NF ✱ C – ✱ ✱ ✱
Full Adjustment 5 Turns
+
Nominal
Capacity
c
b
Locating
Shoulder
Control**
B
.16 in.
L Standard Screw
C
.19 in.
D
.25 in.
H Calibrated
Handknob with
Detent Lock
E
.38 in.
K Handknob
F
.56 in.
Maximum Diameter Orifice
C .16 in.
C .19 in.
D .10 in.
A .25 in.
B .13 in.
a
E .38 in.
F .28 in.
2
Port
** See page 244 for information
on Control Options
Port 1
G .56 in.
H .38 in.
Seal
N Buna-N
NFBC
V Viton
NFCC
NFDC
NFEC
NFFC
FULLY ADJUSTABLE NEEDLE WITH REVERSE FREE FLOW CHECK
2
1
Capacity
Typical
Cartridge
Model Code
.16
NCBB – LCN
Cartridge Dimensions
c
a
b
L
H
K
T - 162A
1.22
3/4”
1.59
-
1.73
Installation
Torque
(lb. ft.)
25/30
30/35
Cavity
.19
NCCB – LCN
T - 13A
1.38
7/8”
2.06
2.44
2.31
.25
NCEB – LCN
T - 5A
1.38
1 1/8”
2.44
2.82
2.73
45/50
.38
NCFB – LCN
T - 16A
1.81
1 1/4”
2.66
3.06
2.91
150/160
.56
NCGB – LCN
T - 18A
2.50
1 5/8”
3.31
3.50
3.47
350/375
OPTION ORDERING INFORMATION
NC ✱ B – ✱ ✱ ✱
Full Adjustment 5 Turns
+
-
Nominal
Capacity
c
b
Locating
Shoulder
Control**
Cracking Pressure*
Seal
NCBB*0.16” dia.
L Standard Screw
A 4 psi
N Buna-N
NCCB 0.19” dia.
NCCC.09” dia.
H Calibrated
Handknob wit
Detent Lock
C 30 psi
V Viton
NCEB.25” dia.
NCEC.13” dia.
E 75 psi
K Handknob
NCFB.38” dia.
NCFC.28” dia.
2
Port
Port 1
a
NCGB.56” dia.
NCGC.38” dia.
** See page 244 for information
on Control Options
110
*Cracking Pressure Ranges:
A and E ranges are not available
in T-162A cavity
US Selected Assemblies Catalogue #999-901-192
NEEDLE / RESTRICTOR
TECHNICAL TIPS / PERFORMANCE CURVES
Needle Valves, Fully Adjustable
Performance Curves
Adjustment Sensitivity at 100 psi Differential
NFBC-L*N
NFCC-L*N
7
Flow = GPM
5
Flow = GPM
Applications
These adjustable needle valves offer accurate and
precise flow control because of their balanced
adjustment design. They may be used for bidirectional operation.
Design Concepts and Features
■
Sharp-edge orifice minimizes flow variation with
viscosity changes.
■
Optional needle orifice ranges. See page 110.
■
Positive shut-off of flow when closed.
3.75
2.5
LCN
1.25
0
1
2
3
4
Number of Turns
5.25
3.5
1
2
3
4
5
Number of Turns
NFEC-L*N
40
Flow = GPM
20
Flow = GPM
LDN
0
5
NFDC-L*N
LCN
1.75
15
10
LAN
5
LBN
0
1
2
3
4
Number of Turns
30
20
LEN
LFN
10
0
5
1
2
3
4
Number of Turns
5
NFFC-L*N
Flow = GPM
80
60
40
LGN
LHN
20
0
1
2
3
4
Number of Turns
5
Needle Valves, Fully Adjustable with Reverse Free Flow Check
B C
P = psi
300
E
F
G
200
Adjustment Sensitivity at 100 psi Differential
NCBB-L*N
NCCB-L*N
6
Flow = GPM
Flow = GPM
6
5
4
3
2
1
0
1
2
3
4
Number of Turns
5
4
3
2
1
0
5
NCEB-L*N
1
6
4
2
40
80
120
2
3
4
5
20
15
10
5
1
2
3
4
5
3
4
5
Number of Turns
0
1
Number of Turns
60
50
40
30
20
10
1
2
Number of Turns
General Application Requirements
■
5
25
NCGB-L*N
Flow = GPM
Flow = GPM
0
■
4
100
0
■
3
30
10
8
0
■
2
Number of Turns
NCFB-L*N
12
Flow = GPM
Reverse Flow Pressure Drop
with Needle Closed
Performance Curves
Flow = GPM
Applications
These adjustable needle valves with integral reverse
free flow check fit the same cavity as the needle valve
without check.
Design Concepts and Features
■ Performance parameters of the adjustable needle
cartridge with check are similar to the NF*C.
However, the leakage rate when closed is
approximately 5 drops / min. or less.
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at a 4 GPM flow rate.
US Selected Assemblies Catalogue #999-901-192
111
NEEDLE / RESTRICTOR
Line Mounted Assemblies
TWO PORT FLOW CONTROL APPLICATIONS
(90 DEGREE BODIES)
Go to www.sunhydraulics.com
for more product information and pricing.
FULLY ADJUSTABLE NEEDLE
0-.16 in.
2
FULLY ADJUSTABLE NEEDLE WITH
REVERSE FREE FLOW CHECK
Cavity T-162A
2
1.00
.50
1
Ports
1 and 2
1
0
Assembly
Model Code*
1/4” NPTF
NFBC-L*N-AAA
3/8” NPTF
NFBC-L*N-AAB
SAE-4
NFBC-L*N-AAH
SAE-6
NFBC-L*N-AAI
0
.50
1.22
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
L Control
1.56 Max.
2
Assembly
Model Code*
1/4” NPTF
NCBB-L*N-AAA
3/8” NPTF
NCBB-L*N-AAB
SAE-4
NCBB-L*N-AAH
SAE-6
NCBB-L*N-AAI
1
1.50
0 .28
1.33
0-.19 in.
2
Ports
1 and 2
Mounting Holes:
.28 diameter through hole
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.00
Cavity T-13A
2
1.25
.62
1
1
Ports
1 and 2
0
Assembly
Model Code*
1/4” NPTF
NFCC-L*N-GAA
3/8” NPTF
NFCC-L*N-GAB
SAE-4
NFCC-L*N-GAH
SAE-6
NFCC-L*N-GAI
SAE-8
NFCC-L*N-GAJ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Mounting Holes:
.34 diameter through hole
0
.28
1.00
2
Assembly
Model Code*
1/4” NPTF
NCCB-L*N-GAA
3/8” NPTF
NCCB-L*N-GAB
SAE-4
NCCB-L*N-GAH
1
1.62
0 .28
1.44
0-.25 in.
2
L Control
2.03 Max.
Ports
1 and 2
SAE-6
NCCB-L*N-GAI
SAE-8
NCCB-L*N-GAJ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.19
Cavity T-5A
2
1.50
.75
1
Ports
1 and 2
1
0
Assembly
Model Code*
1/4” NPTF
NFDC-L*N-DAA
3/8” NPTF
NFDC-L*N-DAB
1/2” NPTF
NFDC-L*N-DAC
SAE-4
NFDC-L*N-DAI
SAE-6
NFDC-L*N-DAJ
SAE-8
NFDC-L*N-DAK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Ports
1 and 2
Mounting Holes:
.42 diameter through hole
0
.38
1.25
L Control
2.38 Max.
2
1/4” NPTF
NCEB-L*N-DAA
3/8” NPTF
NCEB-L*N-DAB
1/2” NPTF
NCEB-L*N-DAC
1
2.00
0 .38
1.69
2.62
Assembly
Model Code*
SAE-4
NCEB-L*N-DAI
SAE-6
NCEB-L*N-DAJ
SAE-8
NCEB-L*N-DAK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
112
US Selected Assemblies Catalogue #999-901-192
TWO PORT FLOW CONTROL APPLICATIONS
(90 DEGREE BODIES)
Go to www.sunhydraulics.com
for more product information and pricing.
FULLY ADJUSTABLE
0-.38 in.
FULLY ADJUSTABLE WITH
REVERSE FREE FLOW CHECK
Cavity T-16A
2
2
2.25
G
1
1.12
G
1
0
1/4” NPTF Gauge Port
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
NFEC-L*N-IAD
1” NPTF
NFEC-L*N-IAE
1 1/4” NPTF
NFEC-L*N-IAF
SAE-12
NFEC-L*N-IAL
SAE-16
NFEC-L*N-IAM
Mounting Hole:
.42 diameter through hole
0
L Control
2.60 Max.
2
.50
1
1.88
G
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
NCFB-L*N-IAD
1” NPTF
NCFB-L*N-IAE
1 1/4” NPTF
NCFB-L*N-IAF
SAE-12
NCFB-L*N-IAL
SAE-16
NCFB-L*N-IAM
3.00
1.00
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.62
4.00
0-.56 in.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Cavity T-18A
2
2
2.75
G
1
G
1.38
1
0
1/4” NPTF Gauge Port
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
NFFC-L*N-LAD
1” NPTF
NFFC-L*N-LAE
1 1/4” NPTF
NFFC-L*N-LAF
SAE-12
NFFC-L*N-LAL
SAE-16
NFFC-L*N-LAM
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Mounting Hole:
.42 diameter through hole
0
L Control
3.25 Max.
2
.62
1
2.12
G
3.50
0
1.09
2.81
4.62
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
NCGB-L*N-LAD
1” NPTF
NCGB-L*N-LAE
1 1/4” NPTF
NCGB-L*N-LAF
SAE-12
NCGB-L*N-LAL
SAE-16
NCGB-L*N-LAM
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
113
NEEDLE / RESTRICTOR
Line Mounted Assemblies
NEEDLE / RESTRICTOR
Line Mounted Assemblies
TWO PORT FLOW CONTROL APPLICATIONS
(INLINE BODIES)
0-.16 in.
2
FULLY ADJUSTABLE NEEDLE WITH
REVERSE FREE FLOW CHECK
Go to www.sunhydraulics.com
for more product information and pricing.
FULLY ADJUSTABLEV NEEDLE
Cavity T-162A
2
L Control
1.34 Max.
1
Ports
1 and 2
1
2.00
Assembly
Model Code*
1/4” NPTF
NFBC-L*N-ACA
3/8” NPTF
NFBC-L*N-ACB
SAE-4
NFBC-L*N-ACH
SAE-6
NFBC-L*N-ACI
Ports
1 and 2
1.12
.50
1/4” NPTF
NCBB-L*N-ACA
3/8” NPTF
NCBB-L*N-ACB
SAE-4
NCBB-L*N-ACH
SAE-6
NCBB-L*N-ACI
.25
0
0
1.00
1
2
.56
0
2.56
1.28
Assembly
Model Code*
0
Mounting Holes:
.28 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0-.19 in.
2
Cavity T-13A
2
L Control
2.03 Max.
1
1
2.00
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
NFCC-L*N-GCA
3/8” NPTF
NFCC-L*N-GCB
SAE-4
NFCC-L*N-GCH
SAE-6
NFCC-L*N-GCI
SAE-8
NFCC-L*N-GCJ
1.52
1.13
.59
0
0
1.28
1/4” NPTF
NCCB-L*N-GCA
3/8” NPTF
NCCB-L*N-GCB
SAE-4
NCCB-L*N-GCH
2.56
Mounting Holes:
.34 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
SAE-6
NCCB-L*N-GCI
SAE-8
NCCB-L*N-GCJ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0-.25 in.
2
Assembly
Model Code*
.25
0
0
1.19
1
2
.56
Ports
1 and 2
Cavity T-5A
2
L Control
2.41 Max.
1
1
2.38
Ports
1 and 2
Assembly
Model Code*
1.75
3/8” NPTF
NFDC-L*N-DCB
1.25
3/8” NPTF
NCEB-L*N-DCB
1/2” NPTF
NFDC-L*N-DCC
.63
1/2” NPTF
NCEB-L*N-DCC
SAE-6
NFDC-L*N-DCI
SAE-8
NFDC-L*N-DCJ
SAE-10
NFDC-L*N-DCK
0
1.50
.75
0
Ports
1 and 2
2
1
.31
0
0
1.63
Mounting Holes:
.42 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Assembly
Model Code*
SAE-6
NCEB-L*N-DCI
SAE-8
NCEB-L*N-DCJ
SAE-10
NCEB-L*N-DCK
3.25
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
114
US Selected Assemblies Catalogue #999-901-192
TWO PORT FLOW CONTROL APPLICATIONS
(INLINE/INLINE 1.50”/2.00” SAE C61 FLANGE PORT BODIES)
0-.38 in.
2
FULLY ADJUSTABLE NEEDLE WITH
REVERSE FREE FLOW CHECK
Go to www.sunhydraulics.com
for more product information and pricing.
FULLY ADJUSTABLE NEEDLE
Cavity T-16A
2
L Control
2.61 Max.
1
1
3.88
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
NFEC-L*N-ICD
1” NPTF
NFEC-L*N-ICE
1 1/4” NPTF
NFEC-L*N-ICF
SAE-12
NFEC-L*N-ICL
SAE-16
NFEC-L*N-ICM
Ports
1 and 2
3.00
2.31
1
2
1.16
.50
0
2.25 1.12
0
0
2.31
4.62
Assembly
Model Code*
3/4” NPTF
NCFB-L*N-ICD
1” NPTF
NCFB-L*N-ICE
1 1/4” NPTF
NCFB-L*N-ICF
SAE-12
NCFB-L*N-ICL
SAE-16
NCFB-L*N-ICM
Mounting Holes:
.53 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0-.56 in.
2
Cavity T-18A
2
L Control
2.78 Max.
6.25
1
1
5.00
Ports
1 and 2
Assembly
Model Code*
1 1/2” SAE C61
NFFC-L*N-ZLS
4.00
2
2.00
0
NCGB-L*N-ZLS
0
2.50
5.00
Mounting Holes:
.53 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0-.56 in.
2
1 1/2” SAE C61
0
0
1.88
Assembly
Model Code*
1
1.50
3.75
Ports
1 and 2
Cavity T-18A
2
L Control
2.78 Max.
1
6.25
1
5.00
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
NFFC-L*N-ZLR
4.00
2.00
0
4.12
2.06
0
2
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
NCGB-L*N-ZLR
1
1.50
0
0
2.50
5.00
Mounting Holes:
.53 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
115
NEEDLE / RESTRICTOR
Line Mounted Assemblies
NEEDLE / RESTRICTOR
Line Mounted Assemblies
TWO PORT FLOW CONTROL APPLICATIONS
(2.00” SAE C61/C62 FLANGE PORT BODIES, 2 PORT CAVITY IN PARALLEL)
Go to www.sunhydraulics.com
for more product information and pricing.
FULLY ADJUSTABLE NEEDLE
0-1.10 in.
2
FULLY ADJUSTABLE NEEDLE WITH
REVERSE FREE FLOW CHECK
Cavity T-18A
2
4.94
2.47
1
1
0
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
NFFC-L*N-XZY
0
Mounting Holes:
.375-16 UNC-2B x .62 deep.
2 places.
L Control
3.03 Max.
.94
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
NCGB-L*N-XZY
2.47
4.00
4.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
2.03
4.66
0-1.10 in.
6.56
Cavity T-18A
2
2
5.94
2
2.97
1
1
0
Ports
1 and 2
Assembly
Model Code*
2” SAE C62
NFFC-L*N-VTN
Mounting Holes:
.375-16 UNC x .75 deep. 2 places.
0
L Control
2.75 Max.
1.06
2.97
Ports
1 and 2
Assembly
Model Code*
2” SAE C62
NCGB-L*N-VTN
1
4.88
5.94
0
2.28
4.88
7.12
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
116
US Selected Assemblies Catalogue #999-901-192
Fixed Orifice Pressure Compensated
Flow Control Assemblies
Cartridge Type
Page
2
Fixed Orifice, Pressure Compensated
118
Fixed Orifice, Pressure Compensated with Free Flow Check
118
1
2
1
Line Mounted Assemblies
(Body Type)
2
90 Degree
120
90 Degree with Gauge Port
121
Inline
Inline/Inline 1.50”/2.00” SAE C61 Flange Port
2.00” SAE C61/ C62 Flange Port, 2 Port Cavity in Parallel
122
123
124
1
2
G
1
2
1
US Selected Assemblies Catalogue #999-901-192
117
FLOW CONTROL
Flow Control Valves
FIXED ORIFICE, PRESSURE COMPENSATED
2
1
Capacity
Typical
Cartridge
Model Code
Cavity
Cartridge Dimensions
c
b
X
L
.1-3 GPM
FXBA – LAN
T - 162A
1.22
3/4”
.82
2.11
2.25
Installation
Torque
(lb. ft.)
25/30
.1-6.0 GPM
FXCA – LAN
T - 13A
1.38
7/8”
.75
2.00
2.25
30/35
.1-12.0 GPM
FXDA – LAN
T - 5A
1.62
1 1/8”
.69
2.12
2.38
45/50
.2-25 GPM
FXEA – LAN
T - 16A
2.44
1 1/4”
.97
2.44
2.69
150/160
.2-50 GPM
FXFA – LAN
T - 18A
3.13
1 5/8”
1.19
2.81
3.06
350/375
a
K
OPTION ORDERING INFORMATION
FX ✱ A – ✱ A ✱
Full Adjustment ± 3 Turns
+
Nominal
Capacity
L Control
Control**
B .1-3 GPM
X Control
c
b
Adjustment Range
X Non-adjustable
Factory set
at customer
specified flow
C .1-6.0 GPM
D .1-12.0 GPM
Locating
Shoulder E .2-25 GPM
A Fixed Orifice
Seal
N Buna-N
Customer must specify flow V Viton
L Tuning Adjustment
±25% of customer
specified flow
F .2-50 GPM
K Handknob for
L control
a
2
Port
** See page 244 for information
on Control Options
Port 1
Flow Ranges by Frame Size:
FXBA: .1 - 3 GPM
FXCA: .1 - 6.0 GPM
FXDA: .1 - 12.0 GPM
FXEA: .2 - 25 GPM
FXFA: .2 - 50 GPM
FIXED ORIFICE, PRESSURE COMPENSATED WITH FREE FLOW CHECK
2
1
Capacity
Typical
Cartridge
Model Code
Cavity
a
.1-3 GPM
FCBB – LAN
T - 162A
1.22
Cartridge Dimensions
c
b
X
L
3/4”
.82
2.11
K
2.55
Installation
Torque
(lb. ft.)
25/30
.1-6.0 GPM
FCCB – LAN
T - 13A
1.38
7/8”
.75
2.00
2.25
30/35
.1-12.0 GPM
FCDB – LAN
T - 5A
1.62
1 1/8”
.69
2.12
2.38
45/50
.2-25 GPM
FCEB – LAN
T - 16A
2.44
1 1/4”
.97
2.44
2.69
150/160
.2-50 GPM
FCFB – LAN
T - 18A
3.13
1 5/8”
1.19
2.81
3.06
350/375
OPTION ORDERING INFORMATION
FC ✱ B – ✱ A ✱
Full Adjustment ± 3 Turns
+
Nominal
Capacity
L Control
X Control
B .1-3 GPM
c
b
C .1-6.0 GPM
D .1-12.0 GPM
Locating
Shoulder E .2-25 GPM
F .2-50 GPM
a
Control**
X Non-adjustable
Factory set
at customer
specified flow
A Fixed Orifice
Seal
N Buna-N
Customer must specify flow V Viton
L Tuning Adjustment
±25% of customer
specified flow
K Handknob for
L control
2
Port
Port 1
Adjustment Range
** See page 244 for information
on Control Options
118
Flow Ranges by Frame Size:
FCBB: .1 - 3 GPM
FCCB: .1 - 6.0 GPM
FCDB: .1 - 12.0 GPM
FCEB: .2 - 25 GPM
FCFB: .2 - 50 GPM
US Selected Assemblies Catalogue #999-901-192
TECHNICAL TIPS / PERFORMANCE CURVES
FXCA-*A*
8
Flow = GPM
3
2.25
1.5
0.75
0
6
4
2
1000 2000 3000 4000 5000
FXDA-*A*
P= psi
0
1000 2000 3000 4000 5000
P = psi
FXEA-*A*
32
15
Flow = GPM
Design Concepts and Features
■
Minimum flow change over widely varying load
pressure changes (less than ± 5% over 4500 psi
load change).
■
Selectable fixed orifice size (flow capacity 0.1 to
50 GPM, dependent on frame size).
■ Tunable control option to provide ± 25% variation
of the nominal factory set flow.
Typical Performance
FXBA-*A*
Flow = GPM
NOTE: Accurate pressure-compensated control requires a
195 psi minimum pressure differential be maintained across the
valve
Performance Curves
Flow = GPM
Applications
These pressure-compensated cartridges provide
precise flow regulation for meter-in and meter-out
applications. They also offer accurate control in bleedoff circuits where the load pressure and inlet flow are
relatively constant.
FLOW CONTROL
Flow Control Valves, Fixed Orifice, Pressure Compensated
12.25
7.5
3.75
0
24
16
8
0
1000 2000 3000 4000 5000
FXFA-*A*
1000 2000 3000 4000 5000
P = psi
P = psi
Flow = GPM
60
45
30
15
0
1000 2000 3000 4000 5000
P = psi
Flow Control Valves, Fixed Orifice, Pressure Compensated with Free Flow Check
Reverse Free Flow Pressure Drop
FCBB-*A*
FCCB-*A*
300
300
P = psi
Note: Accurate pressure-compensated control requires a
195 psi minimum pressure differential be maintained across the
valve
Performance Curves
P = psi
Applications
The performance parameters of the FC*B pressure
compensated flow control with free flow check are
identical to the FX*A, but with the addition of a high
capacity free flow check.
200
.1 GPM
100
3 GPM
200
.1 GPM
100
6 GPM
0
2
4
6
8
0
10
2
4
FCDB-*A*
P = psi
P = psi
100
.1 GPM
50
0
.2 GPM
50
4
8
12
Flow = GPM
16
25 GPM
20
0
8
P = psi
200
135
.2 GPM
65
50 GPM
0
16
32
48
64
80
Flow = GPM
General Application Requirements
■
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at a 4 GPM flow rate.
US Selected Assemblies Catalogue #999-901-192
119
40
100
FCFB-*A*
■
32
150
12 GPM
■
10
FCEB-*A*
150
■
8
6
Flow = GPM
Flow = GPM
16
24
Flow = GPM
FLOW CONTROL
Line Mounted Assemblies
TWO PORT FLOW CONTROL APPLICATIONS
(90 DEGREE BODIES)
Go to www.sunhydraulics.com
for more product information and pricing.
FIXED ORIFICE
.1-3 GPM
FIXED ORIFICE WITH
REVERSE FREE FLOW CHECK
Cavity T-162A
2
2
1.00
.50
1
0
1
Mounting Holes:
.28 diameter through hole
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
FXBA-LAN-AAA
0
3/8” NPTF
FXBA-LAN-AAB
.50
SAE-4
FXBA-LAN-AAH
SAE-6
FXBA-LAN-AAI
Ports
1 and 2
L Control
2.08 Max.
2
1
1.22
Assembly
Model Code*
1/4” NPTF
FCBB-LAN-AAA
3/8” NPTF
FCBB-LAN-AAB
SAE-4
FCBB-LAN-AAH
SAE-6
FCBB-LAN-AAI
1.50
0 .28
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.33
.1-6.0 GPM
2
2.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Cavity T-13A
2
1.25
.62
1
Ports
1 and 2
1
0
Assembly
Model Code*
Ports
1 and 2
Mounting Holes:
.34 diameter through hole
1/4” NPTF
FXCA-LAN-GAA
0
3/8” NPTF
FXCA-LAN-GAB
.28
SAE-4
FXCA-LAN-GAH
SAE-6
FXCA-LAN-GAI
SAE-8
FXCA-LAN-GAJ
1.00
L Control
1.97 Max.
2
1
Assembly
Model Code*
1/4” NPTF
FCCB-LAN-GAA
3/8” NPTF
FCCB-LAN-GAB
SAE-4
FCCB-LAN-GAH
SAE-6
FCCB-LAN-GAI
SAE-8
FCCB-LAN-GAJ
1.62
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0 .28
1.44
.1-12.0 GPM
2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.19
Cavity T-5A
2
1.50
.75
1
Ports
1 and 2
1
0
Assembly
Model Code*
1/4” NPTF
FXDA-LAN-DAA
0
3/8” NPTF
FXDA-LAN-DAB
.38
1/2” NPTF
FXDA-LAN-DAC
SAE-4
FXDA-LAN-DAI
SAE-6
FXDA-LAN-DAJ
SAE-8
FXDA-LAN-DAK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Ports
1 and 2
Mounting Holes:
.42 diameter through hole
1.25
L Control
2.06 Max.
2
1
2.00
0 .38
1.69
2.62
Assembly
Model Code*
1/4” NPTF
FCDB-LAN-DAA
3/8” NPTF
FCDB-LAN-DAB
1/2” NPTF
FCDB-LAN-DAC
SAE-4
FCDB-LAN-DAI
SAE-6
FCDB-LAN-DAJ
SAE-8
FCDB-LAN-DAK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 118 for cartridge models FX*A-*** and FC*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
120
US Selected Assemblies Catalogue #999-901-192
TWO PORT FLOW CONTROL APPLICATIONS
(90 DEGREE BODIES)
Go to www.sunhydraulics.com
for more product information and pricing.
FIXED ORIFICE
.2-25 GPM
FIXED ORIFICE WITH
REVERSE FREE FLOW CHECK
Cavity T-16A
2
2
2.25
G
1
1.12
G
1
0
1/4” NPTF Gauge Port
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
FXEA-LAN-IAD
1” NPTF
FXEA-LAN-IAE
1 1/4” NPTF
FXEA-LAN-IAF
SAE-12
FXEA-LAN-IAL
SAE-16
FXEA-LAN-IAM
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Mounting Hole:
.42 diameter through hole
0
L Control
2.38 Max.
2
.50
1
1.88
G
3.00
1.00
0
2.62
.2-50 GPM
4.00
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
FCEB-LAN-IAD
1” NPTF
FCEB-LAN-IAE
1 1/4” NPTF
FCEB-LAN-IAF
SAE-12
FCEB-LAN-IAL
SAE-16
FCEB-LAN-IAM
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Cavity T-18A
2
2
2.75
G
1
1.38
G
1
0
1/4” NPTF Gauge Port
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
FXFA-LAN-LAD
1” NPTF
FXFA-LAN-LAE
1 1/4” NPTF
FXFA-LAN-LAF
SAE-12
FXFA-LAN-LAL
SAE-16
FXFA-LAN-LAM
Mounting Hole:
.42 diameter through hole
0
L Control
2.75 Max.
2
.62
1
2.12
G
3.50
0
1.09
2.81
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Ports
1 and 2
3/4” NPTF
FCFB-LAN-LAD
1” NPTF
FCFB-LAN-LAE
1 1/4” NPTF
FCFB-LAN-LAF
SAE-12
FCFB-LAN-LAL
SAE-16
FCFB-LAN-LAM
4.62
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 118 for cartridge models FX*A-*** and FC*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
Assembly
Model Code*
121
FLOW CONTROL
Line Mounted Assemblies
FLOW CONTROL
Line Mounted Assemblies
TWO PORT FLOW CONTROL APPLICATIONS
(INLINE BODIES)
.1-3 GPM
2
FIXED ORIFICE WITH
REVERSE FREE FLOW CHECK
Go to www.sunhydraulics.com
for more product information and pricing.
FIXED ORIFICE
Cavity T-162A
2
L Control
1.86 Max.
1
1
2.00
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
FXBA-LAN-ACA
3/8” NPTF
FXBA-LAN-ACB
SAE-4
FXBA-LAN-ACH
SAE-6
FXBA-LAN-ACI
Ports
1 and 2
1.12
2
.56
1/4” NPTF
FCBB-LAN-ACA
3/8” NPTF
FCBB-LAN-ACB
SAE-4
FCBB-LAN-ACH
SAE-6
FCBB-LAN-ACI
.25
0
0
1.00 .50
1
0
2.56
1.28
Assembly
Model Code*
0
Mounting Holes:
.28 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.1-6.0 GPM
2
Cavity T-13A
2
L Control
1.97 Max.
1
1
2.00
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
FXCA-LAN-GCA
3/8” NPTF
FXCA-LAN-GCB
SAE-4
FXCA-LAN-GCH
SAE-6
FXCA-LAN-GCI
SAE-8
FXCA-LAN-GCJ
Ports
1 and 2
1.52
1.13
.59
0
0
1.28
FCCB-LAN-GCA
FCCB-LAN-GCB
SAE-4
FCCB-LAN-GCH
2.56
Mounting Holes:
.34 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
SAE-6
FCCB-LAN-GCI
SAE-8
FCCB-LAN-GCJ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.1-12.0 GPM
2
1/4” NPTF
3/8” NPTF
.25
0
0
1.19
1
2
.56
Assembly
Model Code*
Cavity T-5A
2
L Control
2.09 Max.
1
1
2.38
Ports
1 and 2
Assembly
Model Code*
Ports
1 and 2
1.75
1.25
3/8” NPTF
FXDA-LAN-DCB
1/2” NPTF
FXDA-LAN-DCC
.63
SAE-6
FXDA-LAN-DCI
0
SAE-8
FXDA-LAN-DCJ
SAE-10
FXDA-LAN-DCK
1.50
.75
0
2
1
.31
0
0
1.63
Mounting Holes:
.42 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Assembly
Model Code*
3/8” NPTF
FCDB-LAN-DCB
1/2” NPTF
FCDB-LAN-DCC
SAE-6
FCDB-LAN-DCI
SAE-8
FCDB-LAN-DCJ
SAE-10
FCDB-LAN-DCK
3.25
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 118 for cartridge models FX*A-*** and FC*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
122
US Selected Assemblies Catalogue #999-901-192
TWO PORT FLOW CONTROL APPLICATIONS
(INLINE/INLINE 1.50”/2.00” SAE C61 FLANGE PORT BODIES)
.2-25 GPM
2
FIXED ORIFICE WITH
REVERSE FREE FLOW CHECK
Go to www.sunhydraulics.com
for more product information and pricing.
FIXED ORIFICE
Cavity T-16A
2
L Control
2.39 Max.
1
1
3.88
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
FXEA-LAN-ICD
1” NPTF
FXEA-LAN-ICE
1 1/4” NPTF
FXEA-LAN-ICF
SAE-12
FXEA-LAN-ICL
SAE-16
FXEA-LAN-ICM
3.00
Ports
1 and 2
2.31
1
2
1.16
.50
0
2.25
1.12
0
0
2.31
4.62
Mounting Holes:
.53 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3/4” NPTF
FCEB-LAN-ICD
1” NPTF
FCEB-LAN-ICE
1 1/4” NPTF
FCEB-LAN-ICF
SAE-12
FCEB-LAN-ICL
SAE-16
FCEB-LAN-ICM
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.2-50 GPM
2
Assembly
Model Code*
Cavity T-18A
2
L Control
2.28 Max.
6.25
1
1
5.00
Ports
1 and 2
Assembly
Model Code*
1 1/2” SAE C61
FXFA-LAN-ZLS
4.00
2
2.00
1 1/2” SAE C61
FCFB-LAN-ZLS
0
0
1.88
Assembly
Model Code*
1
1.50
3.75
Ports
1 and 2
0
0
2.50
5.00
Mounting Holes:
.53 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.2-50 GPM
2
Cavity T-18A
2
L Control
2.28 Max.
6.25
1
1
5.00
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
FXFA-LAN-ZLR
4.00
2
2.00
1
1.50
0
4.12
2.06
0
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
FCFB-LAN-ZLR
0
0
2.50
5.00
Mounting Holes:
.53 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 118 for cartridge models FX*A-*** and FC*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
123
FLOW CONTROL
Line Mounted Assemblies
FLOW CONTROL
Line Mounted Assemblies
TWO PORT FLOW CONTROL APPLICATIONS
(2.00” SAE C61/C62 FLANGE PORT BODIES, 2 PORT CAVITY IN PARALLEL)
FIXED ORIFICE
Go to www.sunhydraulics.com
for more product information and pricing.
.2-100 GPM
2
Cavity T-18A
2
4.94
2.47
1
1
0
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
FXFA-LAN-XZY
Mounting Holes:
.375-16 UNC-2B x .62 deep.
2 places.
0
L Control
2.53 Max.
.94
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
FCFB-LAN-XZY
2.47
4.00
4.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
2.03
4.66
.2-100 GPM
6.56
Cavity T-18A
2
5.94
2
2.97
1
0
Ports
1 and 2
Assembly
Model Code*
2” SAE C62
FXFA-LAN-VTN
Mounting Holes:
.375-16 UNC x .75 deep. 2 places.
0
L Control
2.25 Max.
1.06
1
2.97
4.88
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
2.28
4.88
7.12
NOTES: Page 118 for cartridge models FX*A-*** and FC*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
124
US Selected Assemblies Catalogue #999-901-192
Fully Adjustable Pressure Compensated
Flow Control Assemblies
Cartridge Type
Page
2
Fully Adjustable Pressure Compensated with Free Flow Check
126
1
Line Mounted Assemblies
(Body Type)
2
90 Degree
128
90 Degree with Gauge Port
129
Inline
Inline/Inline 1.50”/2.00” SAE C61 Flange Port
2.00” SAE C61/C62 Flange Port, 2 Port Cavities
130
131
132
1
2
G
1
2
1
US Selected Assemblies Catalogue #999-901-192
125
FLOW CONTROL
Flow Control Valves
FULLY ADJUSTABLE PRESSURE COMPENSATED
WITH FREE FLOW CHECK
Full Adjustment 5 Turns
+
2
c
b
1
Locating
Shoulder
a
2
Port
Port 1
Capacity
Typical
Cartridge
Model Code
Cavity
a
Cartridge Dimensions
c
b
L
H
K
Installation
Torque
(lb. ft.)
30/35
.1-6 GPM
FDBA – LAN
T - 13A
1.38
7/8”
2.27
2.44
.1-12 GPM
FDCB – LAN
T - 5A
1.62
1 1/8”
2.35
2.82
2.73
45/50
.2-25 GPM
FDEA – LAN
T - 16A
2.44
1 1/4”
2.66
3.06
2.91
150/160
.2-50 GPM
FDFA – LAN
T - 18A
3.13
1 5/8”
3.31
3.50
3.47
350/375
2.31
OPTION ORDERING INFORMATION
FD ✱ ✱
Nominal
Capacity
–
Control**
BA .1-6 GPM
L
Standard Screw
CB .1-12 GPM
H
Calibrated
Handknob with
Detent Lock
EA .2-25 GPM
FA .2-50 GPM
✱A✱
K
Adjustment Range
FDBA
A .1 - 6 GPM
Seal
N Buna-N
V Viton
FDCB
A .1 - 12 GPM
Handknob
FDEA
A .1 - 25 GPM
FDFA
A .1 - 50 GPM
** See page 244 for information
on Control Options
126
US Selected Assemblies Catalogue #999-901-192
Flow Control Valves, Fully Adjustable, Pressure Compensated with Free Flow Check
Performance Curves
Reverse Free Flow
with Needle Closed
Typical Performance
FDBA-LAN
10
Flow = GPM
P = psi
300
200
100
0
2
4
6
Flow = GPM
8
10
8
6
4
2
0
1000 2000 3000 4000 5000
P = psi
FDCB-LAN
15
Flow = GPM
P = psi
300
200
100
0
4
8
12
Flow = GPM
16
12
9
6
3
20
0
1000 2000 3000 4000 5000
0
1000 2000 3000 4000 5000
0
1000 2000 3000 4000 5000
P = psi
FDEA-LAN
30
Flow = GPM
300
P = psi
Applications
The fully adjustable pressure compensated flow
control (FD** series) is similar in function to the
(FC*B) fixed orifice model with check. However, the
FD** series offers full adjustment over the entire flow
range of the cartridge.
Design Concepts and Features
■
Sharp edge orifice design to minimize flow
variation with viscosity change.
■
Five turns of adjustment with low operating effort
at high pressure.
■
Optional needle ranges to provide different flow
capacity. See page 110.
■
Leakage at shutoff:
FDBA and FDCB
0.08 GPM
FDEA and FDFA
0.1 GPM
■
Optional adjustment control options are as follows:
– Standard screw adjustment
– Handknob with locking ring
– Calibrated handknob with detent lock
200
100
0
10
20
30
40
24
18
12
6
50
Flow = GPM
P = psi
FDFA-LAN
60
Flow = GPM
P = psi
300
200
100
0
20
40
60
Flow = GPM
80 100
48
36
24
12
General Application Requirements
■
■
■
■
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
Factory Pressure Setting for cartridge is established at a 4 GPM flow rate.
US Selected Assemblies Catalogue #999-901-192
127
P = psi
FLOW CONTROL
TECHNICAL TIPS / PERFORMANCE CURVES
FLOW CONTROL
Line Mounted Assemblies
TWO PORT FLOW CONTROL APPLICATIONS
(90 DEGREE BODIES)
FULLY ADJUSTABLE WITH
REVERSE FREE FLOW CHECK
Go to www.sunhydraulics.com
for more product information and pricing.
.1-6.0 GPM
2
Cavity T-13A
1.25
.62
1
0
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
FDBA-LAN-GAA
0
3/8” NPTF
FDBA-LAN-GAB
.28
SAE-4
FDBA-LAN-GAH
SAE-6
FDBA-LAN-GAI
SAE-8
FDBA-LAN-GAJ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Mounting Holes:
.34 diameter through hole
L Control
2.03 Max.
2
1.00
1
1.62
0 .28
1.44
.1-12.0 GPM
2
2.19
Cavity T-5A
1.50
.75
1
0
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
FDCB-LAN-DAA
0
3/8” NPTF
FDCB-LAN-DAB
.38
1/2” NPTF
FDCB-LAN-DAC
SAE-6
FDCB-LAN-DAI
SAE-8
FDCB-LAN-DAJ
SAE-10
FDCB-LAN-DAK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Mounting Holes:
.42 diameter through hole
L Control
2.38 Max.
2
1
1.25
2.00
0 .38
1.69
.0-12.0 GPM
2
2.62
Cavity T-5A
2.12
0
0
1
Ports
1 and 2
Assembly
Model Code*
3/4 NPTF
FDCB-LAN-DAD
.75
0
.50
0
2
.50
1.50
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Mounting Holes:
.42 diameter through hole
3.00
L Control
2.38 Max
1
2.25
NOTES: Page 126 for cartridge model FD**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
128
US Selected Assemblies Catalogue #999-901-192
TWO PORT FLOW CONTROL APPLICATIONS
(90 DEGREE BODIES)
FULLY ADJUSTABLE WITH
REVERSE FREE FLOW CHECK
Go to www.sunhydraulics.com
for more product information and pricing.
.2-25 GPM
2
Cavity T-16A
2.25
G
1
1.12
0
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
FDEA-LAN-IAD
1” NPTF
FDEA-LAN-IAE
1 1/4” NPTF
FDEA-LAN-IAF
SAE-12
FDEA-LAN-IAL
SAE-16
FDEA-LAN-IAM
1/4” NPTF Gauge Port
Mounting Hole:
.42 diameter through hole
0
L Control
2.60 Max.
2
1.50
1
1.88
G
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3.00
1.00
0
2.62
4.00
.2-50 GPM
2
Cavity T-18A
2.75
G
1
1.38
0
1/4” NPTF Gauge Port
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
FDFA-LAN-LAD
0
1” NPTF
FDFA-LAN-LAE
.62
1 1/4” NPTF
FDFA-LAN-LAF
SAE-12
FDFA-LAN-LAL
SAE-16
FDFA-LAN-LAM
Mounting Hole:
.42 diameter through hole
L Control
3.25 Max.
2
1
2.12
G
3.50
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
1.09
2.81
4.62
NOTES: Page 126 for cartridge model FD**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
129
FLOW CONTROL
Line Mounted Assemblies
FLOW CONTROL
Line Mounted Assemblies
TWO PORT FLOW CONTROL APPLICATIONS
(INLINE BODIES)
FULLY ADJUSTABLE WITH
REVERSE FREE FLOW CHECK
Go to www.sunhydraulics.com
for more product information and pricing.
.1-6.0 GPM
2
Cavity T-13A
L Control
2.03 Max.
1
Ports
1 and 2
Assembly
Model Code*
1/4” NPTF
FDBA-LAN-GCA
3/8” NPTF
FDBA-LAN-GCB
SAE-4
FDBA-LAN-GCH
SAE-6
FDBA-LAN-GCI
SAE-8
FDBA-LAN-GCJ
2.00
1.52
1.13
.25
0
0
1.19
.59
1
2
.56
0
0
1.28
2.56
Mounting Holes:
.34 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.1-12.0 GPM
2
Cavity T-5A
L Control
2.41 Max.
1
2.38
1.75
Ports
1 and 2
Assembly
Model Code*
3/8” NPTF
FDCB-LAN-DCB
1/2” NPTF
FDCB-LAN-DCC
.63
SAE-6
FDCB-LAN-DCI
0
SAE-8
FDCB-LAN-DCJ
SAE-10
FDCB-LAN-DCK
1.25
1.50
.75
0
2
1
.31
0
0
1.63
3.25
Mounting Holes:
.42 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 126 for cartridge model FD**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
130
US Selected Assemblies Catalogue #999-901-192
TWO PORT FLOW CONTROL APPLICATIONS
(INLINE/INLINE 1.50”/2.00” SAE C61 FLANGE PORT BODIES)
FULLY ADJUSTABLE WITH
REVERSE FREE FLOW CHECK
Go to www.sunhydraulics.com
for more product information and pricing.
.2-25 GPM
2
Cavity T-16A
L Control
2.13 Max.
1
Ports
1 and 2
Assembly
Model Code*
3/4” NPTF
FDEA-LAN-ICD
1” NPTF
FDEA-LAN-ICE
1 1/4” NPTF
FDEA-LAN-ICF
SAE-12
FDEA-LAN-ICL
SAE-16
FDEA-LAN-ICM
3.88
3.00
2.31
1
2
1.16
.50
0
2.25 1.12
0
0
2.31
4.62
Mounting Holes:
.53 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.2-50 GPM
2
Cavity T-18A
L Control
2.78 Max.
6.25
1
5.00
Ports
1 and 2
Assembly
Model Code*
1 1/2” SAE C61
FDFA-LAN-ZLS
4.00
2
2.00
1
1.50
0
0
3.75
1.88
0
0
2.50
5.00
Mounting Holes:
.53 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.2-50 GPM
2
Cavity T-18A
L Control
2.78 Max.
6.25
1
5.00
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
FDFA-LAN-ZLR
4.00
2
2.00
1
1.50
0
4.12
2.06
0
0
0
2.50
5.00
Mounting Holes:
.53 diameter through hole.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 126 for cartridge model FD**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
131
FLOW CONTROL
Line Mounted Assemblies
FLOW CONTROL
Line Mounted Assemblies
TWO PORT FLOW CONTROL APPLICATIONS
(2.00” SAE C61/C62 FLANGE PORT BODIES, 2 CAVITIES)
FULLY ADJUSTABLE WITH
REVERSE FREE FLOW CHECK
Go to www.sunhydraulics.com
for more product information and pricing.
.5-105 GPM
2
Cavity T-18A
4.94
2.47
1
0
Ports
1 and 2
Assembly
Model Code*
2” SAE C61
FDFA-LAN-XZY
0
Mounting Holes:
.375-16 UNC-2B x .62 deep.
2 places.
L Control
3.03 Max.
.94
2.47
4.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
4.94
0
2.03
4.66
.5-105 GPM
6.56
Cavity T-18A
2
5.94
2
2.97
1
0
Ports
1 and 2
Assembly
Model Code*
2” SAE C62
FDFA-LAN-VTN
Mounting Holes:
.375-16 UNC x .75 deep. 2 places.
0
L Control
3.23 Max.
1.06
1
2.97
4.88
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
2.28
4.88
7.12
NOTES: Page 126 for cartridge models model FD**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
132
US Selected Assemblies Catalogue #999-901-192
Fixed Orifice Priority Flow Control Assemblies
Cartridge Type
Page
3
2
Bypass/Restrictive, Fixed Orifice
134
1
Line Mounted Assemblies
(Body Type)
3
2
90 Degree High Capacity Port 3
136
90 Degree High Capacity with Gauge Port
137
Relief on Controlled Port
138
1
3
2
G
1
G
CF
EF
T
P
US Selected Assemblies Catalogue #999-901-192
133
PRIORITY FLOW
CONTROL
Priority Flow Control Valves
BYPASS / RESTRICTIVE, FIXED ORIFICE
3
2
1
Capacity
Typical
Cartridge
Model Code
Cavity
Cartridge Dimensions
c
b
X
L
.1-3 GPM
FRBA – LAN
T - 163A
1.22
3/4”
1.25
2.55
2.77
Installation
Torque
(lb. ft.)
25/30
.1-6.0 GPM
FRCA – LAN
T - 11A
1.38
7/8”
1.19
2.50
2.75
30/35
.1-12.0 GPM
FRDA – LAN
T - 2A
1.38
1 1/8”
1.38
2.81
3.06
45/50
.2-25 GPM
FREA – LAN
T - 17A
1.81
1 1/4”
1.81
3.28
3.53
150/160
.2-50 GPM
FRFA – LAN
T - 19A
2.50
1 5/8”
2.75
3.94
4.19
350/375
a
K
OPTION ORDERING INFORMATION
FR ✱ A – ✱ A ✱
Full Adjustment ± 3 Turns
+
-
Nominal
Capacity
L Control
B .1-3 GPM
X Control
C .1-6.0 GPM
c
b
D .1-12.0 GPM
E .2-25 GPM
3
Priority
Flow
Locating
Shoulder
2
Bypass
Flow
Inlet 1
a
F .2-50 GPM
Maximum Inlet Flow:
FRBA: 7.5 GPM
FRCA: 15 GPM
FRDA: 30 GPM
FREA: 60 GPM
FRFA: 120 GPM
Control**
X Non-adjustable
Factory set
at customer
specified flow
Adjustment Range
A Fixed Orifice
Seal
N Buna-N
Customer must specify flow V Viton
L Tuning Adjustment
±25% of customer
specified flow
K Handknob for
L control
** See page 244 for information
on Control Options
134
Priority Flow ranges:
FRBA: .1 - 3 GPM
FRCA: .1 - 6.0 GPM
FRDA: .1 - 12.0 GPM
FREA: .2 - 25 GPM
FRFA: .2 - 50 GPM
US Selected Assemblies Catalogue #999-901-192
TECHNICAL TIPS / PERFORMANCE CURVES
Applications
These combination priority and bypass flow control
valves may be used to establish the flow to the priority
or controlled flow circuit, and either bypass the
remaining flow to tank at the load induced pressure of
the system or use it in a secondary system.
Application Notes
■
Valve will not bypass unless priority flow is
satisfied.
■
Bypass pressure may exceed priority pressure.
■
Blocking the controlled flow path will also block
the bypass flow path.
■ Note factory set point conditions.
Design Concepts and Features
■
Customer specified, fixed orifice for priority flow.
(Flow setting accuracy ± 10%.)
■
Tunable control option to provide ± 25% variation
of the customer specified flow at factory preset
conditions.
Performance Curves
Note: Tunable adjustment range follows performance curve profile.
FRDA-LAN
PRIORITY FLOW
CONTROL
Priority Flow Control Valves, Fixed Orifice, Bypass / Restrictive
Typical Performance
Priorty Flow
GPM
5
Priorty Flow
GPM
FRBA-LAN
5
Factory Set Point
with 8 GPM inlet (max.)
with 6 GPM inlet
with 4 GPM inlet
4
3
2
Valve Set @ 3 GPM
with 8 GPM inlet (max.)
1
with 4 GPM inlet
Valve Set @ 1 GPM
0
5000 3000 1000 0 1000 3000 5000
Bypass pressure P = psi Priority pressure
higher than priority
higher than bypass
FRCA-LAN
Factory Set Point
with 15 GPM inlet (max.)
with 10 GPM inlet
with 5 GPM inlet
4
3
2
Valve Set @ 3 GPM
with 15 GPM inlet (max.)
with 5 GPM inlet
Valve Set @ 1 GPM
0
5000 3000 1000 0 1000 3000 5000
Bypass pressure P = psi Priority pressure
higher than priority
higher than bypass
1
Priorty Flow
GPM
Factory Set Point
10
with 30 GPM inlet (max.)
with 20 GPM inlet
with 10 GPM inlet
8
6
Valve Set @ 6 GPM
4
2
with 30 GPM inlet (max.)
with 10 GPM inlet
Valve Set @ 2 GPM
0
5000 3000 1000 0 1000 3000 5000
Bypass pressure P = psi Priority pressure
higher than priority
higher than bypass
FREA-LAN
Factory Set Point
Priorty Flow
GPM
20
FRFA-LAN
with 60 GPM inlet (max.)
with 40 GPM inlet
with 20 GPM inlet
16
12
Valve Set @ 12 GPM
8
4
with 60 GPM inlet (max.)
with 20 GPM inlet
Valve Set @ 4 GPM
0
5000 3000 1000 0 1000 3000 5000
Bypass pressure P = psi Priority pressure
higher than priority
higher than bypass
Priorty Flow
GPM
Factory Set Point
50
40
30
Valve Set @ 30 GPM
with 120 GPM inlet (max.)
with 80 GPM inlet
with 40 GPM inlet
20
with 120 GPM inlet (max.)
with 40 GPM inlet
Valve Set @ 10 GPM
0
5000 3000 10000 1000 3000 5000
Bypass pressure P = psi Priority pressure
higher than priority
higher than bypass
10
General Application Requirements
■
■
■
Operating Temperature Range: Buna-N seals -50° F to 200° F, Viton seals 0° F to 250° F.
Viscosity Range: 60-3000 SUS.
Fluid Contamination Level: ISO 4406 18/15 or better; Recommend β10≥75 to achieve ISO 18/15 or better in most systems.
US Selected Assemblies Catalogue #999-901-192
135
PRIORITY FLOW
CONTROL
Line Mounted Assemblies
THREE PORT PRIORITY FLOW CONTROL APPLICATIONS
(90 DEGREE HIGH CAPACITY PORT 3 BODIES)
BYPASS / RESTRICTIVE
FIXED ORIFICE
Go to www.sunhydraulics.com
for more product information and pricing.
.1-3 GPM
Cavity T-163A
3
2
1.00
.50
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1/4” NPTF
1/4” NPTF
FRBA-LAN-JCA
3/8” NPTF
1/4” NPTF
FRBA-LAN-JCB
SAE-4
SAE-4
FRBA-LAN-JCH
SAE-6
SAE-4
FRBA-LAN-JCI
Mounting Holes:
.28 diameter through hole
2 places.
0
.28
L Control
1.91 Max.
2
1
.97
3
2.00
1.31
0
2.14 2.59
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
.1-6.0 GPM
3
2
Cavity T-11A
1.25
.62
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
3/8” NPTF
FRCA-LAN-EAB
1/2” NPTF
3/8” NPTF
FRCA-LAN-EAC
SAE-8
SAE-8
FRCA-LAN-EAJ
SAE-10
SAE-8
FRCA-LAN-EAK
Mounting Holes:
.34 diameter through hole, 2 places.
0
.38
L Control
1.81 Max.
2
1
1.25
3
2.50
.44
0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
1.56
2.44 3.00
.1-12.0 GPM
3
2
Cavity T-2A
1.50
.75
1
0
Ports
1 and 2
Port 3
Assembly
Model Code*
3/8” NPTF
3/8” NPTF
FRDA-LAN-BAB
1/2” NPTF
1/2” NPTF
FRDA-LAN-BAC
3/4” NPTF
1/2” NPTF
FRDA-LAN-BAD
SAE-8
SAE-8
FRDA-LAN-BAJ
SAE-10
SAE-10
FRDA-LAN-BAK
SAE-12
SAE-10
FRDA-LAN-BAL
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
Mounting Holes:
.42 diameter through hole. 2 places.
0
L Control
2.00 Max.
2
.50
1
1.62
3
3.00
0
.50
1.72
2.66 3.25
NOTES: Page 134 for cartridge model FR*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
136
US Selected Assemblies Catalogue #999-901-192
THREE PORT PRIORITY FLOW CONTROL APPLICATIONS
(90 DEGREE, HIGH CAPACITY PORT 3 BODIES)
BYPASS / RESTRICTIVE
FIXED ORIFICE
Go to www.sunhydraulics.com
for more product information and pricing.
.2-25 GPM
3
Cavity T-17A
2.25
2
G
1
1.12
0
Ports
1 and 2
Port 3
Assembly
Model Code*
3/4” NPTF
3/4” NPTF
FREA-LAN-HED
1” NPTF
3/4” NPTF
FREA-LAN-HEE
1 1/4” NPTF
3/4” NPTF
FREA-LAN-HEF
SAE-12
SAE-12
FREA-LAN-HEL
SAE-16
SAE-12
FREA-LAN-HEM
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
Mounting Holes:
.42 diameter through hole, 2 places.
0
L Control
2.16 Max.
2
.75
1
2.00
G
3
4.00
1.19
0
2.12
.2-50 GPM
3.44 4.25
Cavity T-19A
3
3.00
2
G
1
1.50
0
Ports
1 and 2
Port 3
Assembly
Model Code*
1” NPTF
1” NPTF
FRFA-LAN-KEE
1 1/4” NPTF
1” NPTF
FRFA-LAN-KEF
SAE-20
SAE-16
FRFA-LAN-KEN
Mounting Holes:
.42 diameter through hole, 2 places.
0
.50
L Control
2.56 Max.
2
1
2.50
G
3
5.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0
1.06
2.50
4.31 5.25
NOTES: Page 134 for cartridge model FR*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
137
PRIORITY FLOW
CONTROL
Line Mounted Assemblies
PRIORITY FLOW
CONTROL
Line Mounted Assemblies
THREE PORT PRESSURE-COMPENSATED PRIORITY FLOW CONTROL
APPLICATIONS (RELIEF ON CONTROLLED PORT BODIES)
UP TO 6.5 GPM
PRIORITY FLOW
Go to www.sunhydraulics.com
for more product information and pricing.
.1-6.0 GPM
G
Cavity T-11A
CF
1.50
EF
T
P
0
1.69
Ports (EF)
Excess Flow
& (P) Pump
Ports (CF)
Control Flow
& (T) Tank
Assembly
Model Code*
1/4” NPTF
1/4” NPTF
YRDR-LAN-LA
3/8” NPTF
3/8” NPTF
YRDR-LAN-LB
1/2” NPTF
3/8” NPTF
YRDR-LAN-LC
SAE-6
SAE-6
YRDR-LAN-LI
SAE-8
SAE-8
YRDR-LAN-LJ
SAE-10
SAE-8
YRDR-LAN-LK
3.62
Mounting Holes:
.34 diameter through hole. 2 places.
3.62
3.25
L Control
1.69 Max.
EF
P
2.12
1.94 Max.
T
L Control
CF
0
*Add modifier /S to order Ductile Iron for pressure rating over
3000 psi.
UP TO 12.5 GPM
PRIORITY FLOW
.97 1.69
0
2.66 3.25
.1-12.0 GPM
G
1/4” NPTF
Gauge
Port
G
Cavity T-2A
CF
1.50
EF
T
P
0
1.69
Ports (EF)
Excess Flow
& (P) Pump
Ports (CF)
Control Flow
& (T) Tank
Assembly
Model Code*
1/2” NPTF
1/2” NPTF
YREM-LAN-LC
3/4” NPTF
1/2” NPTF
YREM-LAN-LD
SAE-10
SAE-10
YREM-LAN-LK
SAE-12
SAE-10
YREM-LAN-LL
3.62
Mounting Holes:
.34 diameter through hole. 2 places.
3.62
3.25
L Control
1.69 Max.
EF
P
2.12
1.94 Max.
1/4” NPTF
Gauge
Port
G
*Add modifier /S to order Ductile Iron for pressure rating over
3000 psi.
UP TO 25 GPM
PRIORITY FLOW
T
L Control
0
CF
.97 1.69
0
.2-25 GPM
G
2.66 3.25
Cavity T-17A
CF
2.25
EF
T
P
0
Ports (EF)
Excess Flow
& (P) Pump
Ports (CF)
Control Flow
& (T) Tank
Assembly
Model Code*
3/4” NPTF
3/4” NPTF
YRFF-LAN-LD
5.25
1” NPTF
3/4” NPTF
YRFF-LAN-LE
4.50
1 1/4” NPTF
3/4” NPTF
YRFF-LAN-LF
SAE-12
SAE-12
YRFF-LAN-LL
SAE-16
SAE-12
YRFF-LAN-LM
0
2.09
5.25
Mounting Holes:
.41 diameter through hole. 2 places.
L Control
2.38 Max.
EF
P
3.25
L Control
1.94 Max.
G
*Add modifier /S to order Ductile Iron for pressure rating over
3000 psi.
T
1/4” NPTF
Gauge
Port
CF
0
0
.88
3.19 4.00
NOTES: Page 134 for cartridge model FR*A-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
138
US Selected Assemblies Catalogue #999-901-192
Sandwich Assemblies
Page
140
142
143
Technical Product Information
Studkits
Studrod Length Determination Chart
Sandwich Assemblies
Body Type
Page
Body Type
Page
145
147
148
149
150
ISO 07/CETOP 7 Valves
Relief
Sequence
Reducing
Reducing/Relieving
Counterbalance
183
185
186
187
188
151
Pilot-to-Open Check
189
152
153
Check
Flow Control
190
191
154
Circuit Saver
192
ISO 08/CETOP 8 Valves
Relief
Sequence
Reducing
Reducing/Relieving
Counterbalance
Pilot-to-Open Check
Check
Flow Control
Circuit Saver
193
195
196
197
198
199
200
201
202
ISO 03/CETOP 3 Valves
Relief
Relief, Vented
Sequence
Reducing
Reducing/Relieving
Counterbalance and
Vented Counterbalance
Pilot-to-Open Check
Check
Flow Control and Priority
Flow Control
Flow Control
Circuit Saver
155
158
ISO 05/CETOP 5 Valves
Relief
Relief, Vented
Sequence
Reducing
Reducing/Relieving
Counterbalance
Pilot-to-Open Check
Check
Flow Control
161
163
164
165
166
167
168
169
170
ISO 05 with X and Y Valves
Relief
Sequence
Reducing
Reducing/Relieving
Counterbalance
Pilot-to-Open Check
Check
Flow Control
173
175
176
177
178
179
180
181
US Selected Assemblies Catalogue #999-901-192
139
Sandwich Bodies
TECHNICAL PRODUCT INFORMATION
Click Here for
MOUNTING and ASSEMBLY of SANDWICH BODIES
Technical Tips
See Product > Technical Information > Technical Tips for Sun Products
140
US Selected Assemblies Catalogue #999-901-192
Sandwich Bodies
TECHNICAL PRODUCT INFORMATION
Click Here for
MOUNTING and ASSEMBLY of SANDWICH BODIES
Technical Tips
See Product > Technical Information > Technical Tips for Sun Products
US Selected Assemblies Catalogue #999-901-192
141
Sandwich Bodies
TECHNICAL PRODUCT INFORMATION
Click Here for
MOUNTING and ASSEMBLY of SANDWICH BODIES
Technical Tips
See Product > Technical Information > Technical Tips for Sun Products
142
US Selected Assemblies Catalogue #999-901-192
Sandwich Bodies
TECHNICAL PRODUCT INFORMATION
Click Here for
MOUNTING and ASSEMBLY of SANDWICH BODIES
Technical Tips
See Product > Technical Information > Technical Tips for Sun Products
US Selected Assemblies Catalogue #999-901-192
143
Sandwich Bodies
NOTES
144
US Selected Assemblies Catalogue #999-901-192
ISO 03 / CETOP 3 RELIEF VALVES
(SIDE PORTED SUBPLATE / REAR PORTED SUBPLATE / SIDE PORTED SUBPLATE WITH
P AND T IN BASE)
T-10A Cavity
All subplates shown below are 3.5” wide.
PILOT OPERATED
DIRECT ACTING
Function
2.00
p
t
b
a
P
A
B
T
Ports
A, B, P, T
3/8” NPTF
SAE-8
Assembly
Model Code*
RPEC-LAN-FSB
RPEC-LAN-FSJ
0
Mounting Holes:
.28 diameter through hole.
4 places
3.50
3.17
2.38
B
1.12
A
.33
0
L Control
2.35
Max.
t
a
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
P to T
T
1.00
G
b
p
Gauge Port 1/4” NPTF
0
.38
Assembly
Model Code*
RDDA-LAN-FSB
RDDA-LAN-FSJ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
P
1.25
Ports
A, B, P, T
3/8” NPTF
SAE-8
2.00
p
t
b
G
P
Ports
A, B, P, T
3/8” NPTF
SAE-8
T
B
Function
2.00
a
A
Assembly
Model Code*
RPEC-LAN-FRB
RPEC-LAN-FRJ
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
P to T
1.00
0
Mounting Holes:
.28 diameter through hole.
4 places.
L Control
3.50
3.17
2.35
Max.
t
a
1.14
b
p
.33
0
0
.38
Ports
A, B, P, T
3/8” NPTF
SAE-8
Assembly
Model Code*
RDDA-LAN-FRB
RDDA-LAN-FRJ
Gauge Port 1/4” NPTF
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.00
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information and pricing.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
145
ISO 03 / CETOP 3
Sandwich Assemblies
ISO 03 / CETOP 3 RELIEF VALVES
T-10A Cavity
All sandwich bodies
shown below are 1.75” wide
PILOT OPERATED
b
Function
a
Gauge Port
1/4” NPTF
1.70
P RELIEF
NOTCH
1
G
T
B
A
P RELIEF
NOTCH
1
0
RPEC-LAN-FBP
.05
(4) – 012 O–rings
Function
a
G
Gauge Port
1/4” NPTF
A to T (High Capacity)
B to T (High Capacity)
1.70
2
1
1
G
2
P
B
T
0
A
NOTCH
RPEC-LAN-FBA
.05
2
1
B
G
1.70
G
0
A
1
A to B (High Capacity)
B to A (High Capacity)
P RELIEF
NOTCH
L Control
2.35
Max.
2.25
Assembly
Model Code*
RPEC-LAN-FBC
b
(4) – 012 O–rings
RDDA-LAN-FBC
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
a
2
1.70
A to B and B to A
(High Capacity) (Cross-Port)
2
t
.05
Assembly
Model Code*
.33
Locating Pin
NOTCH
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
RDDA-LAN-FBA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Gauge Port
1/4” NPTF
2
T
Assembly
Model Code*
Function
a
1
P
(4) – 012 O–rings
P RELIEF
NOTCH
b
L Control
2.35
Max.
.33
Locating Pin
2.25
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
t
P RELIEF
NOTCH
1
Assembly
Model Code*
p
RDDA-LAN-FBP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
P RELIEF
NOTCH
b
t
Assembly
Model Code*
.33
Locating Pin
NOTCH
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
L Control
2.35
Max.
2.25
Assembly
Model Code*
2
P
P to T
2
t
2
p
DIRECT ACTING
2
NOTCH
1
1
0
P
T
B
L Control
2.35
Max.
A
Assembly
Model Code*
2.25
.69
.69
NOTCH
RPEC-LAN-FBY
.05
t
b
RDDA-LAN-FBY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
a
1.70
A and B to T
(High Capacity)
2
NOTCH
1
P
T
B
1
0
A
Assembly
Model Code*
L Control
2.35
Max.
1.00
2.25
1.00
.05
L Control
2.35
Max.
Locating Pin
NOTCH
RPEC-LAN-FBX
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
Assembly
Model Code*
Locating Pin
(4) – 012 O–rings
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
L Control
2.35
Max.
2
ISO 03 / CETOP 3
Sandwich Assemblies
(4) – 012 O–rings
Assembly
Model Code*
RDDA-LAN-FBX
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
146
US Selected Assemblies Catalogue #999-901-192
ISO 03 / CETOP 3 RELIEF VALVES, VENTED
T-11A Cavity
All sandwich bodies
shown below are 1.75” wide
PILOT OPERATED
b
Function
1.70
a
NOTCH
t
RVCA
2
p
2
1
0
1
P
T
B
A
NOTCH
L Control
1.81
Max.
.80
2.25
1.05
P to T
(Normally Open, Solenoid Vented)
2.92
NOTCH
Assembly
Model Code*
Locating Pin
.05
XRCO-LAN-HA
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
(4) – 012 O–rings
Operating pressure is limited to 5000 psi.
Coil must be selected separately. See page 248.
Function
b
1.70
a
NOTCH
t
RVCA
2
p
2
1
1
0
P
T
B
A
2.92
Assembly
Model Code*
NOTCH
Locating Pin
NOTCH
.05
XRCO-LAN-CA
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
L Control
1.81
Max.
.80
2.25
1.05
P to T
(Normally Closed, Solenoid Vented)
(4) – 012 O–rings
Operating pressure is limited to 5000 psi.
Coil must be selected separately. See page 248.
Function
b
a
P to T (Externally Vented)
1.70
SAE-6
Vent Port
NOTCH
t
2
1
P
T
B
A
1
0
NOTCH
2.25
Vent
Port
Assembly
Model Code*
SAE-6
RVCA-LAN-EBC
2
p
.39
NOTCH
.80
L Control
1.81
Max.
Locating Pin
(4) – 012 O–rings
.05
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 12 for cartridge model RV*A-*** show performance curves, technical tips, and options.
Select Solenoid Connector Option from Page 248.
See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
US Selected Assemblies Catalogue #999-901-192
147
ISO 03 / CETOP 3
Sandwich Assemblies
ISO 03 / CETOP 3 SEQUENCE VALVES
T-11A Cavity
All sandwich bodies
shown below are 1.75” wide
PILOT OPERATED
DIRECT ACTING
Function
p
t
b
Gauge Port
1/4” NPTF
a
2
1.70
In to P
2
G
1
P
T
B
A
NOTCH
1
0
2.25
Assembly
Model Code*
NOTCH
RSDC-LAN-EBW/M
t
b
a
SXCA-LAN-EBW
(4) – 012 O–rings
.05
1.70
NOTCH
p
Assembly
Model Code*
Locating Pin
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
In to A (Reverse Free Flow Check)
2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
L Control
2.40
Max.
.66
2
“B” PORT CONTROL
1
CXCA
1
0
L Control
1.81
Max.
2
P
T
B
A
NOTCH
2.25
1.31
Assembly
Model Code*
.88
NOTCH
RSDC-LAN-EB4
b
(4) – 012 O–rings
2
1.70
Out of A (Reverse Free Flow Check)
“A” PORT CONTROL
CXCD
“B” PORT CONTROL
1
1
1.70
2
P
T
B
A
.72
.88
Assembly
Model Code*
RSDC-LAN-EB5
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
In to B (Reverse Free Flow Check)
a
1
Assembly
Model Code*
SXCA-LAN-EB4
.05
NOTCH
t
.72
Locating Pin
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
Out of B (Reverse Free Flow Check)
“A” PORT CONTROL
1
2
ISO 03 / CETOP 3
Sandwich Assemblies
NOTCH
2.25
1.31
NOTCH
L Control
1.81
Max.
Locating Pin
.05
(4) – 012 O–rings
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Assembly
Model Code*
SXCA-LAN-EB5
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Pages 20 and 29 for cartridge models RS*C-***, SX*A-*** and SC*A-*** show performance curves, technical tips, and options.
See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
148
US Selected Assemblies Catalogue #999-901-192
ISO 03 / CETOP 3 REDUCING VALVES
T-11A Cavity
All sandwich bodies
shown below are 1.75” wide
PILOT OPERATED
b
Function
a
Gauge Port
1/4” NPTF
2
G
1.70
On P Drained to T
2
t
p
1
T
P
B
A
1
0
L Control
1.81
.66
Max.
Assembly
Model Code*
NOTCH
2.25
PBDB-LAN-EBP
NOTCH
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
Locating Pin
(4) – 012 O–rings
.05
Function
a
2
Gauge Port
1/4” NPTF
1.70
2
G
1
On A Drained to B
On B Drained to A
4
“A” PORT CONTROL
G
3
P
T
B
NOTCH
1
0
L Control
1.81
Max.
A
Assembly
Model Code*
2.25
1.31
Locating Pin
NOTCH
PBDB-LAN-EBA
.05
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
(4) – 012 O–rings
Function
t
b
a
1.70
“A” PORT CONTROL
1
1
P
T
B
0
L Control
2.40
Max.
A
Assembly
Model Code*
1.31
2.25
.88
NOTCH
PBDB-LAN-EB2
t
b
a
P
T
B
A
.05
(4) – 012 O–rings
Function
1.70
0
.72
Assembly
Model Code*
2.25
.88
a
(4) – 012 O–rings
Function
1.70
2
2
1
1
P
T
B
A
Assembly
Model Code*
PBDB-LAN-EBY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
L Control
1.81
Max.
Locating Pin
.05
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
b
1.31
NOTCH
PBDB-LAN-EB3
t
On B Drain to T
(Reverse Free Flow Check)
“B” PORT CONTROL
1
NOTCH
CXDA
1
p
.72
Locating Pin
2
p
CXDA
NOTCH
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
On A Drain to T
(Reverse Free Flow Check)
2
p
On A and B
(Drains to Opposite Port)
NOTCH
0
L Control
1.81
Max.
1.31
2.25
NOTCH
.05
1.31
L Control
1.81
Max.
Locating Pin
(4) – 012 O–rings
Page 34 for cartridge model PB*B-*** show performance curves, technical tips, and options.
See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
149
ISO 03 / CETOP 3
Sandwich Assemblies
ISO 03 / CETOP 3 REDUCING / RELIEVING VALVES
T-11A Cavity
All sandwich bodies
shown below are 1.75” wide
PILOT OPERATED
p
b
t
DIRECT ACTING
a
Function
On P Tank to T, Drained at T
Gauge Port
1/4” NPTF
G
2
1.70
2
1
P
B
T
A
1
0
L Control
2.40
.66
Max.
Assembly
Model Code*
NOTCH
PPDB-LAN-EBP
NOTCH
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
PRDB-LAN-EBP
Locating Pin
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
(4) – 012 O–rings
.05
a
Function
Gauge Port
1/4” NPTF
2
1
Assembly
Model Code*
2.25
1.70
On A Tank to B
2
On B Tank to A
G
4
“A” PORT CONTROL
G
3
P
T
B
A
Assembly
Model Code*
b
.05
(4) – 012 O–rings
PRDB-LAN-EBA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
1.70
a
Assembly
Model Code*
Locating Pin
NOTCH
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
t
2.25
1.31
PPDB-LAN-EBA
p
NOTCH
1
0
L Control
2.40
Max.
2
On A Tank to T
(Reverse Free Flow Check)
2
“A” PORT CONTROL
1
1
P
T
B
0
L Control
2.40
Max.
A
Assembly
Model Code*
1.31
2.25
.88
NOTCH
PPDB-LAN-EB2
t
b
PRDB-LAN-EB2
(4) – 012 O–rings
1.70
a
2
B
A
.72
2.25
.88
PPDB-LAN-EB3
2
B
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
a
A
Assembly
Model Code*
1.70
On A and B
Tanks and Drains to Opposite Port
NOTCH
0
L Control
1.81
Max.
1.31
2.25
1.31
NOTCH
PPDB-LAN-EBY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
PRDB-LAN-EB3
(4) – 012 O–rings
1
T
Assembly
Model Code*
Locating Pin
.05
1
P
L Control
2.40
Max.
2
b
1.31
NOTCH
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
t
Function
On B Tank to T, Drained to T
(Reverse Free Flow Check)
0
Assembly
Model Code*
p
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
“B” PORT CONTROL
1
NOTCH
CXDA
T
Assembly
Model Code*
.05
1
P
.72
Locating Pin
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
CXDA
NOTCH
2
ISO 03 / CETOP 3
Sandwich Assemblies
.05
L Control
2.40
Max.
Locating Pin
(4) – 012 O–rings
Assembly
Model Code*
PRDB-LAN-EBY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Page 42 for cartridge models PP*B-*** and PR*B-*** show performance curves, technical tips, and options.
See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
150
US Selected Assemblies Catalogue #999-901-192
ISO 03 / CETOP 3 COUNTERBALANCE / VENTED COUNTERBALANCE VALVES
T-11A / T21A Cavity
All sandwich bodies
shown below are 1.75” wide
PILOT RATIOS
2.3:1, 4.5:1 and 10:1 (CB**)
and 5:1 and 2:1 (CW**)
PILOT RATIOS
3:1 and 1.5:1 (CB**) and 3:1 and 1:1 (CW**)
p
t
b
Function
STANDARD
a
2
4
1.70
On B Pilot from A
2
G
3
P
T
B
“A” PORT CONTROL
A
1
0
Assembly
Model Code*
1.28
Max.
L Control
CBC*-LHN-EBA
*The 4th digit of the Model Code must be entered to specify
counterbalance pilot ratio. Add modifier /S to order Ductile Iron
for pressure rating over 3000 psi.
t
b
NOTCH
1.31
Assembly
Model Code*
2.25
NOTCH
.05
Locating Pin
CBC*-LJN-EBA
(4) – 012 O–rings
*The 4th digit of the Model Code must be entered to specify
counterbalance pilot ratio. Add modifier /S to order Ductile Iron
for pressure rating over 3000 psi.
Function
a
2
1
1.70
On A and B (Cross-Piloted)
2
p
On A Pilot from B
Gauge Port
1/4” NPTF
G
1
1
NOTCH
0
P
T
B
A
1.28
Max.
L Control
Assembly
Model Code*
1.31
2.25
NOTCH
CBC*-LHN-EBY
b
(4) – 012 O–rings
VENTED
a
1.70
Assembly
Model Code*
CBC*-LJN-EBY
*The 4th digit of the Model Code must be entered to specify
counterbalance pilot ratio. Add modifier /S to order Ductile Iron
for pressure rating over 3000 psi.
Function
On A Pilot from B, Vent to T
2
t
1.28
Max.
L Control
Locating Pin
.05
*The 4th digit of the Model Code must be entered to specify
counterbalance pilot ratio. Add modifier /S to order Ductile Iron
for pressure rating over 3000 psi.
p
1.31
2
1
P
T
B
A
1
0
Assembly
Model Code*
1.72
Max.
L Control
CWC*-LHN-MBA
b
2
T
B
.05
(4) – 012 O–rings
1.70
0
A
1
2.25
1.72
Max.
L Control
Locating Pin
t
b
.05
(4) – 012 O–rings
1.70
2
1
1
0
P
T
B
A
Assembly
Model Code*
CWC*-LHN-MBY
1.72
Max.
L Control
1.81
CWC*-LGN-MBB
*The 4th digit of the Model Code must be entered to specify
counterbalance pilot ratio. Add modifier /S to order Ductile Iron
for pressure rating over 3000 psi.
On A and B
(Cross-Piloted, vents to T)
NOTCH
2.25
.05
1.81
1.72
Max.
L Control
Locating Pin
(4) – 012 O–rings
*The 4th digit of the Model Code must be entered to specify
counterbalance pilot ratio. Add modifier /S to order Ductile Iron
for pressure rating over 3000 psi.
NOTES:
Assembly
Model Code*
Function
a
2
p
Function
On B Pilot from A, Vent to T
1.64
NOTCH
CWC*-LHN-MBB
*The 4th digit of the Model Code must be entered to specify
counterbalance pilot ratio. Add modifier /S to order Ductile Iron
for pressure rating over 3000 psi.
NOTCH
Assembly
Model Code*
*The 4th digit of the Model Code must be entered to specify
counterbalance pilot ratio. Add modifier /S to order Ductile Iron
for pressure rating over 3000 psi.
CWC*-LGN-MBA
Locating Pin
a
1
P
Assembly
Model Code*
2
t
2.25
NOTCH
*The 4th digit of the Model Code must be entered to specify
counterbalance pilot ratio. Add modifier /S to order Ductile Iron
for pressure rating over 3000 psi.
p
NOTCH
1.64
Assembly
Model Code*
CWC*-LGN-MBY
*The 4th digit of the Model Code must be entered to specify
counterbalance pilot ratio. Add modifier /S to order Ductile Iron
for pressure rating over 3000 psi.
Page 50 for cartridge model CB**-*** and page 70 for cartridge model CW**-*** show performance curves, technical tips, and options.
See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
151
ISO 03 / CETOP 3
Sandwich Assemblies
ISO 03 / CETOP 3 PILOT-TO-OPEN CHECK VALVES
T-11A / T-21A Cavity
All sandwich bodies
shown below are 1.75” wide
PILOT OPERATED
p
t
b
VENTED
STANDARD
a
2
1
1.70
4
G
P
T
B
1
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
a
2.25
NOTCH
.05
(4) – 012 O–rings
Function
1.70
2
1
1
P
T
B
Locating Pin
On A and B (Cross-Piloted)
2
b
NOTCH
X Control
1.31
.50
Max.
CKCB-XCN-EBA
t
On B Pilot from A
“A” PORT CONTROL
A
Assembly
Model Code*
p
On A Pilot from B
Gauge Port
1/4” NPTF
G
3
Function
2
NOTCH
0
A
X Control
X Control
1.31
Assembly
Model Code*
2.25
1.31
1.81
Max.
Locating Pin
.50
Max.
NOTCH
CKCB-XCN-EBY
.05
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
(4) – 012 O–rings
VENTED
Function
On A Pilot from B Vent to T
1.70
p
t
b
2
a
2
0
NOTCH
1
1
1.64
P
T
B
2.25
X Control
1.15
Max.
A
NOTCH
.05
(4) – 012 O–rings
1.70
p
t
b
0
1
2
B
Function
On B Pilot from A, Vent to T
1.64
X Control
1.15
Max.
Locating Pin
A
NOTCH
.05
b
a
2
1
P
T
B
CVCV-XCN-MBB
Function
On A and B Cross-Piloted, Vents to T
2
t
Assembly
Model Code*
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
(4) – 012 O–rings
1.70
p
CVCV-XCN-MBA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTCH
2.25
T
Assembly
Model Code*
a
1
P
Locating Pin
2
ISO 03 / CETOP 3
Sandwich Assemblies
A
0
1.15
Max.
X Control
1
1.81
NOTCH
1.81
2.25
1.15
Max.
X Control
Locating Pin
NOTCH
.05
(4) – 012 O–rings
Assembly
Model Code*
CVCV-XCN-MBY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 78 for cartridge models CK**-*** and page 94 for cartridge model CV*V-*** show performance curves, technical tips, and options.
See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
152
US Selected Assemblies Catalogue #999-901-192
ISO 03 / CETOP 3
Sandwich Assemblies
ISO 03 / CETOP 3 CHECK VALVES
T-13A / T-5A Cavity
All sandwich bodies
shown below are 1.75” wide
FREE FLOW
PORT 1 TO 2
t
b
Function
a
2
1.70
On P
2
p
On T
1
1
P
T
B
NOTCH
1
0
2
T
2.25
A
Assembly
Model Code*
.72
.14 Max.
NOTCH
CXDA-XCN-GDP
Locating Pin
(4) – 012 O–rings
.05
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
b
p
a
t
b
a
1.70
NOTCH A
t
4
2
3
On A Free Flow Into Valve
2
p
1
On A Free Flow Out Valve
1
3
4
2
P
T
B
P
A
1
0
T
B
NOTCH B
A
2.25
Assembly
Model Code*
On B Free Flow Into Valve
NOTCH
CXDA-XCN-GDA
On B Free Flow Out Valve
.50 .72
Max
Locating Pin
(4) – 012 O–rings
.05
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
b
a
1.70
NOTCH
t
Function
On A and B, Free Flow Out of Valve
2
p
2
1
On A and B, Free Flow Into Valve
1
1
0
NOTCH
2
P
T
B
A
2.25
.72 .69
Max.
Assembly
Model Code*
.69 .72
Max.
NOTCH
CXDA-XCN-GDY
Locating Pin
.05
(4) – 012 O–rings
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
t
b
a
P
T
B
A
1.70
2
1
NOTCH
1
0
1.56
CXFA-XAN-GDF
(4) – 012 O–rings
Function
a
1.70
B PORT CONTROL
NOTCH
b
.05
T to A
2
t
.658
Max.
Locating Pin
NOTCH
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
1.56
2.25
.658
Max.
Assembly
Model Code*
Function
T to A and B (High Capacity)
2
p
1
2
T to B
2
0
1
P
T
B
A
1
A PORT CONTROL
NOTCH
.72 .14
Max
Assembly
Model Code*
2.25
NOTCH
CXDA-XAN-GDW
Locating Pin
.05
(4) – 012 O–rings
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
Page 102 for cartridge models CX*A-*** and CX*D-*** show performance curves, technical tips, and options.
See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
153
ISO 03 / CETOP 3 FLOW CONTROL / PRIORITY FLOW CONTROL VALVES
T-13A / T-11A Cavity
All sandwich bodies
shown below are 1.75” wide
FULLY ADJUSTABLE NEEDLE
PRESSURE COMPENSATED
WITH REVERSE FREE FLOW CHECK
FULLY ADJUSTABLE NEEDLE
p
t
b
Function
a
3
1.70
Meter-In P
2
4
Meter-Out T
2
1
0
P
T
B
A
Note: Reverse Checks on
FDBA-LAN-GBP Only
“T” PORT CONTROL
1
NOTCH
L Control
2.03
Max.
.14
2.25
Assembly
Model Code*
NOTCH
NFCC-LCN-GBP
.05
b
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
a
1.19
B1
NOTCH
t
FDBA-LAN-GBP
(4) – 012 O–rings
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
Assembly
Model Code*
Locating Pin
Function
Bleed-Off A to B and B to A
2
2
A1
1
0
1
P
T
B
NOTCH
L Control
1.97
Max.
.25
A
2.25
Assembly
Model Code*
NOTCH
NFCC-LCN-GBS
Locating Pin
.05
(4) – 012 O–rings
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
t
b
Function
a
2
1.70
NOTCH
p
Bleed-Off A to T
2
“B” PORT CONTROL
1
Bleed-Off B to T
1
2
“A” PORT CONTROL
1
NOTCH
0
P
T
B
A
.14
Assembly
Model Code*
NOTCH
Locating Pin
NFCC-LCN-GBW
.05
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
L Control
2.03
Max.
2.25
a
(4) – 012 O–rings
Function
1.70
2
Bleed-Off A and B to T
2
1
P
T
B
1
0
A
L Control
2.03
Max.
Assembly
Model Code*
t
b
a
.05
Function
Priority Flow on P, Bypass to T
2
B
Locating Pin
PRIORITY FLOW CONTROL
FIXED ORIFICE
1.70
T
L Control
2.03
Max.
(4) – 012 O–rings
1
P
.81
NOTCH
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
NOTCH
2.25
.81
NFCC-LCN-GBX
2
ISO 03 / CETOP 3
Sandwich Assemblies
A
Assembly
Model Code*
0
NOTCH
2.25
FRCA-LAN-WBN**
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1
.66
NOTCH
.05
L Control
2.20
Max.
Locating Pin
(4) – 012 O–rings
**Customer must specify priority flow.
NOTES:
Page 110 for cartridge model NF*C-***, page 126 for FD*A-***, and page 134 for FR*A-*** show performance curves, technical tips, and options.
See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
154
US Selected Assemblies Catalogue #999-901-192
ISO 03 / CETOP 3 FLOW CONTROL VALVES
T-13A Cavity
All sandwich bodies
shown below are 1.75” wide
FULLY ADJUSTABLE NEEDLE
WITH REVERSE FREE FLOW CHECK
FULLY ADJUSTABLE, PRESSURE
COMPENSATED WITH FREE FLOW CHECK
Function
a
p
t
b
a
3
1
2
Meter-In A
1.70
NOTCH
b
t
4
METER IN A
4
1
B
T
Meter-Out A
2
3
P
2
p
A
P
T
B
1
0
A
Meter-In B
METER OUT B
NOTCH
2.25
Assembly
Model Code*
.50
NOTCH
b
.05
(4) – 012 O–rings
FDBA-LAN-GBA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
a
1.70
METER OUT
NOTCH
t
Assembly
Model Code*
Meter-In A and B
2
p
Meter-Out B
Locating Pin
NCCB-LCN-GBA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
L Control
2.03
Max.
2
1
Meter-Out A and B
1
METER IN
1
0
2
T
B
L Control
2.03
Max.
A
Assembly
Model Code*
2.25
.69
NCCB-LCN-GBY
b
L Control
2.03
Max.
Assembly
Model Code*
Locating Pin
(4) – 012 O–rings
.05
FDBA-LAN-GBY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
a
2
1.70
“B” PORT CONTROL
NOTCH
t
.69
NOTCH
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
NOTCH
1
Bleed-Off A to T
2
P
Bleed-Off B to T
1
2
1
0
P
T
B
“A” PORT CONTROL
NOTCH
A
2.25
.14
Assembly
Model Code*
NOTCH
NCCB-LAN-GBW
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
L Control
2.03
Max.
(4) – 012 O–rings
.05
Assembly
Model Code*
Locating Pin
FDBA-LAN-GBW
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
t
b
a
P
T
B
A
1.70
2
1
Assembly
Model Code*
NCCB-LAN-GBX
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
L Control
2.03
Max.
Bleed-Off A and B to T
2
p
1
NOTCH
2.25
.81
NOTCH
.81
L Control
2.03
Max.
Locating Pin
Assembly
Model Code*
FDBA-LAN-GBX
.05
(4) – 012 O–rings
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 110 for cartridge model NC*B-*** and page 126 for FD*A-*** show performance curves, technical tips, and options.
See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
155
ISO 03 / CETOP 3
Sandwich Assemblies
ISO 03 / CETOP 3
Sandwich Assemblies
ISO 03 / CETOP 3 FLOW CONTROL VALVES
(RAPID ADVANCE - FINE FEED)
T-13A Cavity
All sandwich bodies
shown below are 1.75” wide
FULLY ADJUSTABLE, PRESSURE
COMPENSATED WITH FREE FLOW CHECK
a
t
p
b
.69
2.91 Max
1.75
t
FDBA
Shown
a
FDBA
Meter-Out T, Solenoid Normally Closed
b
p
FDBA
Shown
A
T
P
B
0
2.753.25
.05
0 .50
0
METER-OUT T
(NOTCH)
1.70
Assembly
Model Code*
X2CD-LAN-CA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
Meter-In P, Solenoid Normally Closed
METER-IN P
(NOTCH)
L Control
2.00 Max.
-012 O-Rings Locating
Pin
Typ (4) Places
Coil must be selected separately. See page 248.
NOTES: Page 126 for cartridge models FD*A-*** show performance curves, technical tips, and options.
See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information and pricing.
156
US Selected Assemblies Catalogue #999-901-192
ISO 03 / CETOP 3 FLOW CONTROL VALVES
(RAPID ADVANCE - FINE FEED)
T-13A Cavity
All sandwich bodies
shown below are 1.75” wide
FULLY ADJUSTABLE, PRESSURE
COMPENSATED WITH FREE FLOW CHECK
b
p
Function
Meter-In A, Solenoid Normally Closed
a
FDBA
Shown
L Control
2.03 Max.
METER-OUT B
(NOTCH)
t
Meter-Out A, Solenoid Normally Closed
METER-IN A
(NOTCH)
Meter-In B, Solenoid Normally Closed
FDBA
FDBA
Shown
Locating
Pin
-012 O-Rings
Typ (4) Places
.72
1.75
a
b
p
0
0
3.25
3.11
.86
B
P
A
Assembly
Model Code*
X4CD-LAN-CA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
L Control
2.03 Max.
.05
0
METER-IN B
(NOTCH)
T
2.91 Max
t
FDBA
Shown
FDBA
Shown
Meter-Out B, Solenoid Normally Closed
METER-OUT A
(NOTCH)
1.70
Coil must be selected separately. See page 248.
NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** show performance curves, technical tips, and options.
See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information and pricing.
US Selected Assemblies Catalogue #999-901-192
157
ISO 03 / CETOP 3
Sandwich Assemblies
ISO 03 / CETOP 3 CIRCUIT SAVERS
(PRESSURE COMPENSATOR / REGENERATIVE / LOAD SENSING / PILOT CHOKE PACK)
T-11A / T-13A Cavity
p
t
b
All sandwich bodies
shown below are 1.75” wide
Function
a
YFCG: Pressure Compensator (Restrictive), 200 psi
2
2.50
2
1
LPDC-XHN
2
Output
1
P
T
B
YFCJ: Pressure Compensator (Restrictive), 200 psi
with external Load-Sensing Port
CSAB-*XN
A
1
0
Output Port
YFCJ: SAE-4
NOTCH
External
Shuttle Port
Assembly
Model Code*
2.25
None
YFCG-XHN-AA
NOTCH
SAE-4
YFCJ-XHN-AA
.75 .50
Locating Pin
.05
(4) – 012 O–rings
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
t
b
a
2
1.19
B1
NOTCH
p
Function
Shuttle A and B (Output External)
Output
1
0
P
T
B
2
ISO 03 / CETOP 3
Sandwich Assemblies
Output Port
SAE-4
A1
NOTCH
1
A
2.25
Assembly
Model Code*
.66
.25 Max.
NOTCH
CSAA-BXN-GBS
Locating Pin
(4) – 012 O–rings
.05
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
a
CODA-XEN
1.70
1
CBCA-LHN
Function
B to A Pressure Sensing Regenerative Circuit
A to B Pressure Sensing Regenerative Circuit
“B” PORT CONTROL
1
P
T
B
A
1
0
Assembly
Model Code*
NOTCH
L Control
1.28
Max.
Locating Pin
2.25
.50 .94
1.31
NOTCH
YDCA-LHN-AA
.05
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
(4) – 012 O–rings
Function
p
b
a
t
PBBB-LAN
NFBC-LCN
Pilot Choke Pack
1.18
P
B
A
T
Assembly
Model Code*
0
L Control
1.94
Max.
L Control
1.56
.38 Max.
Locating Pin
2.25
.87
NOTCH
YNAA-LDN-AA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
(Used typically to control main stage shift time on
pilot operated ISO/CETOP directional valves.)
NOTCH
.05
(4) – 012 O–rings
NOTES: See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
158
US Selected Assemblies Catalogue #999-901-192
ISO 03 / CETOP 3
Sandwich Assemblies
ISO 03 / CETOP 3 CIRCUIT SAVERS
(TAP IN MANIFOLD / ADAPTOR PLATE / COVER PLATE)
All sandwich bodies
shown below are 1.75” wide
Function
p
t
b
a
A and B Tap in Manifold
.94
A
B
P
T
B
Port
Port
A
0
A
B
NOTCH
2.25
Ports
A, B
Assembly
Model Code*
1/4” NPTF
ZWV
SAE-4
ZUO
NOTCH
Locating Pin
.05
(4) – 012 O–rings
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
a
t
b
Function
a
B
P
B
T
A
P
A
T
P
A
T
A
P
B
T
B
P
T
B
A
P
T
B
External
Port
Assembly
Model Code*
1/4” NPTF
ZWW
SAE-4
ZPT
P and A Tap in Manifold
.94
P
b
NOTCH
t
A
p
P and B Tap in Manifold
Port
Port
0
A
P
NOTCH
B
T and A Tap in Manifold
2.25
T and B Tap in Manifold
Locating Pin
(5) – 012 O–rings
.05
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
ISO 03
p
t
b
Adaptor from ISO 05
to ISO 03.
a
1.44
P
T
B
A
0
ISO 05
(5) – 014 O–rings
Assembly
Model Code*
3.00
ZVT
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
p
t
b
a
Cover Plate with
All Ports Blocked
.94
0
P
T
B
A
2.25
Assembly
Model Code*
ZJR
NOTCH
NOTCH
.05
Locating Pin
(4) – 012 O–rings
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTE:
See Page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
159
Sandwich Assemblies
NOTES
160
US Selected Assemblies Catalogue #999-901-192
ISO 05 / CETOP 5 RELIEF VALVES
(SIDE PORTED SUBPLATE / REAR PORTED SUBPLATE / SIDE PORTED SUBPLATE WITH
GASKET MOUNTED TANK PORT)
T-10A Cavity
All subplates shown
below are 4.5” wide
PILOT OPERATED
DIRECT ACTING
Function
p
t
b
Mounting Holes:
.44 diameter through hole. 4 places.
a
4.06
A
P
A
B
T
T
3.31
t
2.16
B
a
b
P to T
L Control
1.75
Max
p
Ports
A, B, P, T
Assembly
Model Code*
RPEC-LAN-FSC
RPEC-LAN-FSK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1/2” NPTF
SAE-10
Ports
A, B, P, T
.44
0
P
4.00 3.56 2.31
1.19 0
.44
Assembly
Model Code*
RDDA-LAN-FSC
RDDA-LAN-FSK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1/2” NPTF
0
1.25 1.94
SAE-10
Function
p
t
b
a
P
T
B
A
Mounting Holes:
.44 diameter through hole. 4 places.
4.50
4.06
L Control
1.75
Max
t
G
b
1.94
Ports
A, B, P, T
a
p
Assembly
Model Code*
1.34
2.12
RPEC-LAN-FRC
RPEC-LAN-FRK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Ports
A, B, P, T
.44
0
G
1/2” NPTF
SAE-10
P to T
RDDA-LAN-FRC
RDDA-LAN-FRK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1/2” NPTF
0 .622.12
0
2.19 1.06
4.00
.44
3.56
1/4” NPTF Gauge Port
Assembly
Model Code*
SAE-10
Function
p
t
b
a
P
A
B
4.50
4.06
A
T
T
t
2.16
Ports
A, B, P, T
Assembly
Model Code*
RPEC-LAN-FTC
RPEC-LAN-FTK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1/2” NPTF
SAE-10
P to T
Mounting Holes:
.44 diameter through hole.
4 places.
B
a
b
L Control
1.75
Max
2.50
p
1.31
.44
0
P
4.00
3.56
O-ring Seal
2.31 1.19 0
.44
0 1.25 1.94
Tank Port
with O-ring Groove
Ports
A, B, P, T
Assembly
Model Code*
RDDA-LAN-FTC
RDDA-LAN-FTK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1/2” NPTF
SAE-10
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information and pricing.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
161
ISO 05 / CETOP 5
Sandwich Assemblies
ISO 05 / CETOP 5
Sandwich Assemblies
ISO 05 / CETOP 5 RELIEF VALVES
T-10A Cavity
All sandwich bodies
shown below are 2.50” wide
PILOT OPERATED
DIRECT ACTING
Function
p
t
b
a
P to T
Gauge Port
1/4” NPTF
1.94
G
P
T
B
A
0
Assembly
Model Code*
Assembly
Model Code*
(5) – 014 O–rings
RPEC-LAN-CBE
3.00
.81
L Control
2.35
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
RDDA-LAN-CBE
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
p
b
t
a
G
P
B
T
A to T
Gauge Port
1/4” NPTF
1.94
A
0
(5) – 014 O–rings
Assembly
Model Code*
3.00
RPEC-LAN-CBF
.81
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
b
t
Assembly
Model Code*
L Control
2.35
Max.
RDDA-LAN-CBF
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
a
Gauge Port
1/4” NPTF
G
P
B
T
B to T
1.94
A
0
(5) – 014 O–rings
Assembly
Model Code*
3.00
RPEC-LAN-CBG
.81
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
Assembly
Model Code*
L Control
2.35
Max.
RDDA-LAN-CBG
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
a
A to B and B to A
(Cross-port)
2.44
P
T
B
0
A
Assembly
Model Code*
RPEC-LAN-CBI
L Control
2.32
Max.
(5) – 014 O–rings
L Control
2.32
3.00
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Assembly
Model Code*
RDDA-LAN-CBI
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
p
t
b
a
A and B to T
1.44
0
P
T
B
A
Assembly
Model Code*
L Control
2.35
.81
Max.
(5) – 014 O–rings
3.00
.81
RPEC-LAN-CBD
Assembly
Model Code*
RDDA-LAN-CBD
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
L Control
2.35
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
162
US Selected Assemblies Catalogue #999-901-192
ISO 05 / CETOP 5 RELIEF VALVES
T-10A Cavity/T-2A Cavity
All sandwich bodies
shown below are 2.50” wide
PILOT OPERATED
p
t
b
DIRECT ACTING
Function
a
Gauge Port
1/4” NPTF
G
1.44
“B” RELIEVES TO “A”
“A” RELIEVES TO “B”
0
P
T
B
B to A
SOLENOID
VALVE
G
A to B
SOLENOID
VALVE
A
.05
Assembly
Model Code*
(5) – 014 O–rings
RPEC-LAN-CBH
RDDA-LAN-CBH
L Control
2.32
Max.
3.00
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
Assembly
Model Code*
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
p
t
b
a
Vent
Vent Port
SAE-6
P to T (Externally Vented)
Gauge Port
1/4” NPTF
2.44
G
P
T
B
A
Vent
Port
1.82
.63
Assembly
Model Code*
0
(5) – 014 O–rings
RVEA-LAN-BBC
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
SAE-6
3.00
1.34
L Control
2.75 Max.
Function
p
t
b
2.44
a
P to T
(Normally Open, Solenoid Vented)
RVEA
P
T
B
0
A
(5) – 014 O–rings
Assembly
Model Code*
3.00
3.15
XRED-LAN-HA
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
1.00
L Control
2.09
Max.
Coil must be selected separately. See page 248.
Function
p
t
b
a
2.44
RVEA
P
T
B
P to T
(Normally Closed, Solenoid Vented)
0
A
(5) – 014 O–rings
Assembly
Model Code*
XRED-LAN-CA
3.00
3.15
1.00
L Control
2.09
Max.
Coil must be selected separately. See page 248.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 2 for cartridge models RP*C-***, RD*A-*** and page 12 for cartridge model RV*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
US Selected Assemblies Catalogue #999-901-192
163
ISO 05 / CETOP 5
Sandwich Assemblies
ISO 05 / CETOP 5 SEQUENCE VALVES
T-2A Cavity
All sandwich bodies
shown below are 2.50” wide
PILOT OPERATED
DIRECT ACTING
Function
p
t
b
a
Gauge Port
1/4” NPTF
In to P
2.44
G
P
T
B
A
0
Assembly
Model Code*
(5) – 014 O–rings
RSFC-LAN-BBW
L Control
2.06
.31 Max.
3.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
Assembly
Model Code*
SXEA-LAN-BBW
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
Into A (Reverse Free Flow Check)
a
2.44
SOLENOID
VALVE
Out of B (Reverse Free Flow Check)
SEQUENCE INTO A
CXED
P
T
B
Assembly
Model Code*
RSFC-LAN-BB4
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
0
A
SOLENOID
VALVE
SEQUENCE OUT OF B
.05
L Control
2.09
Max. .15
(5) – 014 O–rings
3.00
1.10 .62
Assembly
Model Code*
SXEA-LAN-BB4
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
Into B (Reverse Free Flow Check)
a
2.44
SOLENOID
VALVE
Out of A (Reverse Free Flow Check)
SEQUENCE INTO B
CXED
T
B
A
Assembly
Model Code*
SOLENOID
VALVE
P
SEQUENCE OUT OF A
ISO 05 / CETOP 5
Sandwich Assemblies
0
.05
RSFC-LAN-BB5
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.62 1.10
(5) – 014 O–rings
3.00
L Control
2.09
.15 Max.
Assembly
Model Code*
SXEA-LAN-BB5
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 20 for cartridge model RS*C-*** and SX*A-*** and page 102 for CX*D-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
164
US Selected Assemblies Catalogue #999-901-192
ISO 05 / CETOP 5 REDUCING VALVES
T-2A Cavity
All sandwich bodies
shown below are 2.50” wide
PILOT OPERATED
Function
t
p
b
a
G
T
P
B
On P Drained to T
Gauge Port
1/4” NPTF
2.44
A
0
Assembly
Model Code*
(5) – 014 O–rings
PBFB-LAN-BBP
L Control
2.06
Max.
.31
3.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
p
t
b
a
On A Drained to B
Gauge Port
1/4” NPTF
1.94
G
P
T
B
A
0
Assembly
Model Code*
(5) – 014 O–rings
L Control
1.64
3.00
Max.
.50
PBFB-LAN-BBA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
Function
a
On B Drained to A
Gauge Port
1/4” NPTF
1.94
G
P
T
B
A
Assembly
Model Code*
(5) – 014 O–rings
PBFB-LAN-BBB
.50
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
a
L Control
1.64
Max.
3.00
Function
2.44
On A Drain to T
(Reverse Free Flow Check)
SOLENOID
VALVE
CXFA
P
T
B
PBFB-LAN-BB2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
t
b
(5) – 014 O–rings
.05
Assembly
Model Code*
p
0
A
L Control
2.09
Max. .15
a
3.00
1.10 .62
Function
2.44
SOLENOID
VALVE
CXFA
P
T
B
A
Assembly
Model Code*
PBFB-LAN-BB3
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
On B Drain to T
(Reverse Free Flow Check)
0
.05
(5) – 014 O–rings
3.00
.62 1.10
L Control
2.09
Max.
.15
Page 34 for cartridge model PB*B-*** and page 102 for cartridge model CX*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
165
ISO 05 / CETOP 5
Sandwich Assemblies
ISO 05 / CETOP 5
Sandwich Assemblies
ISO 05 / CETOP 5 REDUCING / RELIEVING VALVES
T-2A Cavity
All sandwich bodies
shown below are 2.50” wide
PILOT OPERATED
DIRECT ACTING
Function
p
b
t
a
G
P
B
T
On P, Tank to T
Gauge Port
1/4” NPTF
2.44
A
0
Assembly
Model Code*
Assembly
Model Code*
(5) – 014 O–rings
PPFB-LAN-BBP
L Control
2.06
Max.
.31
3.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
PRFB-LAN-BBP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
p
t
b
a
On A, Tank to T
(Reverse Free Flow Check)
2.44
SOLENOID
VALVE
CXFA
P
T
B
A
0
Assembly
Model Code*
PPFB-LAN-BB2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Assembly
Model Code*
(5) – 014 O–rings
.05
L Control
2.09
Max. .15
PRFB-LAN-BB2
3.00
1.10 .62
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
p
t
b
a
2.44
SOLENOID
VALVE
On B, Tank to T
(Reverse Free Flow Check)
CXFA
P
T
B
A
Assembly
Model Code*
0
.05
(5) – 014 O–rings
PPFB-LAN-BB3
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3.00
.62 1.10
L Control
2.09
Max.
.15
Assembly
Model Code*
PRFB-LAN-BB3
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 42 for cartridge models PP*B-*** and PR*B-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
166
US Selected Assemblies Catalogue #999-901-192
ISO 05 / CETOP 5 COUNTERBALANCE VALVES
T-2A Cavity
All sandwich bodies
shown below are 2.50” wide
PILOT RATIOS
3:1 (CBEA), 1.5:1 (CBEB), 2:1 (CBEY)
PILOT RATIOS
2.3:1 (CBEL), 4.5:1 (CBEG), 10:1 (CBEH)
Function
p
t
b
a
On A, Pilot from B
Gauge Port
1/4” NPTF
1.94
G
P
T
B
A
0
Assembly
Model Code*
Assembly
Model Code*
(5) – 014 O–rings
L Control
1.21
Max. .50
CBE*-LHN-BBA
*The 4th digit of the Model Code must be entered to
specify counterbalance pilot ratio. Add modifier /S to
order Ductile Iron for pressure rating over 3000 psi.
CBE*-LJN-BBA
3.00
*The 4th digit of the Model Code must be entered to
specify counterbalance pilot ratio. Add modifier /S to
order Ductile Iron for pressure rating over 3000 psi.
Function
p
t
b
a
On B, Pilot from A
Gauge Port
1/4” NPTF
1.94
G
P
T
B
A
0
Assembly
Model Code*
Assembly
Model Code*
(5) – 014 O–rings
CBE*-LHN-BBB
L Control
1.21
.50 Max.
3.00
CBE*-LJN-BBB
*The 4th digit of the Model Code must be entered to
specify counterbalance pilot ratio. Add modifier /S to
order Ductile Iron for pressure rating over 3000 psi.
p
t
b
*The 4th digit of the Model Code must be entered to
specify counterbalance pilot ratio. Add modifier /S to
order Ductile Iron for pressure rating over 3000 psi.
Function
a
On A and B (Cross-Piloted)
1.94
P
T
B
A
0
(5) – 014 O–rings
Assembly
Model Code*
CBE*-LHN-BBY
L Control
1.69
1.06
Max.
3.00
1.06
*The 4th digit of the Model Code must be entered to
specify counterbalance pilot ratio. Add modifier /S to
order Ductile Iron for pressure rating over 3000 psi.
p
t
b
Function
a
SOLENOID
VALVE
CXFC
T
B
CBE*-LJN-BBY
*The 4th digit of the Model Code must be entered to
specify counterbalance pilot ratio. Add modifier /S to
order Ductile Iron for pressure rating over 3000 psi.
2.94
P
Assembly
Model Code*
L Control
1.69
Max.
CXFC
Cushion Lock Circuit
On A and B
A
0
Assembly
Model Code*
CBE*-LHN-BB8
*The 4th digit of the Model Code must be entered to
specify counterbalance pilot ratio. Add modifier /S to
order Ductile Iron for pressure rating over 3000 psi.
(5) – 014 O–rings
.05
L Control
1.66
Max. 1.26
3.00
1.26
L Control
1.66
Max.
Assembly
Model Code*
CBE*-LJN-BB8
*The 4th digit of the Model Code must be entered to
specify counterbalance pilot ratio. Add modifier /S to
order Ductile Iron for pressure rating over 3000 psi.
NOTES: Page 50 for cartridge model CB**-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
167
ISO 05 / CETOP 5
Sandwich Assemblies
ISO 05 / CETOP 5
Sandwich Assemblies
ISO 05 / CETOP 5 PILOT-TO-OPEN CHECK VALVES
T-2A Cavity
All sandwich bodies
shown below are 2.50” wide
PILOT OPERATED
Function
p
b
t
a
Gauge Port
1/4” NPTF
1.94
On A, Pilot from B
G
P
B
T
A
0
(5) – 014 O–rings
Assembly
Model Code*
X Control
.21 Max.
CKEB-XCN-BBA
3.00
.50
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
p
b
t
a
On B, Pilot from A
Gauge Port
1/4” NPTF
1.94
G
P
B
T
A
0
(5) – 014 O–rings X Control
.21 Max.
Assembly
Model Code*
3.00
CKEB-XCN-BBB
.50
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
p
t
b
a
On A and B (Cross-piloted)
1.94
P
T
B
A
Assembly
Model Code*
CKEB-XCN-BBY
0
X Control
.69 Max.
1.06
(5) – 014
O–rings
3.00
X Control
.69 Max.
1.06
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 78 for cartridge model CK**-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
168
US Selected Assemblies Catalogue #999-901-192
ISO 05 / CETOP 5
Sandwich Assemblies
ISO 05 / CETOP 5 CHECK VALVES
T-5A Cavity
All sandwich bodies
shown below are 2.50” wide
FREE FLOW
PORT 1 TO 2
p
t
b
a
2.44
P
T
B
A
0
Function
On P
(5) – 014 O–rings
Assembly
Model Code*
3.00
CXFA-XCN-DBP
.518
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
a
1.94
Function
On A, Free Flow Out of Valve
SOLENOID
VALVE
B
On B, Free Flow Into Valve
A
SOLENOID
VALVE
0
P
T
B
.05
A
(5) – 014 O–rings
Assembly
Model Code*
CXFA-XCN-DBK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
a
3.00
.658 .38
Max.
Function
1.94
SOLENOID
VALVE
On A, Free Flow Into Valve
A
On B, Free Flow Out of Valve
B
SOLENOID
VALVE
0
P
T
B
.05
(5) – 014 O–rings
A
Assembly
Model Code*
3.00
CXFA-XCN-DBJ
.38 .658
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
a
P
T
B
A
Function
2.44
0
.05
(5) – 014 O–rings
Assembly
Model Code*
CXFA-XAN-DBW
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
T to A and B
SOLENOID
VALVE
.658
Max.
.81
3.00
.81
.658
Max.
NOTES: Page 102 for cartridge models CX*A-*** and CX*D-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
169
ISO 05 / CETOP 5 FLOW CONTROL VALVES
T-5A Cavity
All sandwich bodies
shown below are 2.50” wide
FULLY ADJUSTABLE NEEDLE
WITH REVERSE FREE FLOW CHECK
p
t
b
FULLY ADJUSTABLE PRESSURE
COMPENSATED WITH FREE FLOW CHECK
Function
a
2.44
P
T
B
A
Note: No Check with NFDC Model
Meter-In P
0
(5) – 014 O–rings
Assembly
Model Code*
NFDC-LAN-DBP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
b
t
Assembly
Model Code*
L Control
2.47
Max.
3.00
FDCB-LAN-DBP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
a
1.94
Meter-Out A
SOLENOID
VALVE
Meter-In B
METER-OUT A
METER-IN B
SOLENOID
VALVE
0
P
B
A
T
Note: Pressure Compensated
Symbol Not Shown
.05
(5) – 014 O–rings
Assembly
Model Code*
NCEB-LAN-DBA
.38
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
Assembly
Model Code*
L Control
2.41
Max.
3.00
FDCB-LAN-DBA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
a
1.94
Meter-In A
SOLENOID
VALVE
METER-OUT B
Meter-Out B
METER-IN A
SOLENOID
VALVE
0
P
T
B
A
Note: Pressure Compensated
Symbol Not Shown
Assembly
Model Code*
NCEB-LAN-DBB
.05
(5) – 014 O–rings
L Control
2.41
Max.
.38
3.00
FDCB-LAN-DBB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
Assembly
Model Code*
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
a
1.44
Bleed-Off A to T
SOLENOID
VALVE
Bleed-Off B to T
“A” PORT CONTROL
“B” PORT CONTROL
SOLENOID
VALVE
0
P
T
B
A
Note: Pressure Compensated
Symbol Not Shown
.05
(5) – 014 O–rings
Assembly
Model Code*
3.00
.75
L Control
2.41
Max.
Assembly
Model Code*
NCEB-LAN-DBC
FDCB-LAN-DBC
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
a
1.94
Meter-In A and B
SOLENOID
VALVE
METER-OUT
Meter-Out A and B
METER-IN
P
T
B
A
Note: Pressure Compensated
Symbol Not Shown
Assembly
Model Code*
NCEB-LAN-DBY
SOLENOID
VALVE
ISO 05 / CETOP 5
Sandwich Assemblies
0
.05
L Control
2.41
Max.
.69
(5) – 014 O–rings
3.00
.69
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
L Control
2.41
Max.
Assembly
Model Code*
FDCB-LAN-DBY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Page 110 for cartridge models NF*C-*** and NC*B-***, and page 126 for FD*B*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
170
US Selected Assemblies Catalogue #999-901-192
ISO 05 / CETOP 5
Sandwich Assemblies
ISO 05 / CETOP 5 FLOW CONTROL VALVES
T-13A Cavity
All sandwich bodies
shown below are 2.50” wide
FULLY ADJUSTABLE NEEDLE
2.50
t
b
p
a
t
L Control
2.41 Max.
T
Meter A to B
Meter B to A
T
B
A
P
T
P
B
A
Function
.60
T
0
3.00
0
0
Assembly
Model Code*
SOLENOID VALVE A1
SOLENOID VALVE B1
NFCC-LCN-DBS
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.50
1.19
.05
(5) – 014 O–rings
NOTES: Page 110 for cartridge models NF*C-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
US Selected Assemblies Catalogue #999-901-192
171
ISO 05 / CETOP 5
Sandwich Assemblies
ISO 05 / CETOP 5 FLOW CONTROL VALVES
(RAPID ADVANCE AND FEED ASSEMBLIES)
All sandwich bodies
shown below are 2.50” wide
FULLY ADJUSTABLE, PRESSURE
COMPENSATED WITH FREE FLOW CHECK
T-5A Cavity
FIXED ORIFICE TUNABLE,
PRESSURE COMPENSATED
Function
Meter-Out T, Solenoid Normally Closed
a
t
ISO 05 PATTERN
.28 DIA THRU-TYP (4) PLACES
b
p
.66
2.91 Max
2.50
FDCB
Shown
T
T
A
B
P
A
T
B
P
.34
0
0
1.13
0
3.69
4.13
5.25
2.44
SOLENOID VALVE
METER-OUT T
Assembly
Model Code*
X3DD-LAN-CA
L Control
2.09 Max
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.05
Coil must be selected separately. See page 248.
Function
Meter in P, Solenoid Normally Closed
2.44
a
t
b
p
SOLENOID VALVE
METER-IN P
FDCB
Shown
L Control
2.06 Max
0
A
T
B
P
.63
2.91 Max
2.50
T
T
A
B
Assembly
Model Code*
P
X2DD-LAN-CA
.34
0
0
1.16
0
3.69
4.16
5.31
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.58
2.50
2.91 Max
T
T
D
B
b
t
p
a
P
.34
3.42
3.86
3.98
FDCB
Shown
0
.86
Assembly
Model Code*
2.94
B
T
P
Function
Meter-Out A, Solenoid Normally Closed
Meter-In B, Solenoid Normally Closed
X6DD-LAN-CA
SOLENOID VALVE
METER-OUT A
A
SOLENOID VALVE
METER-IN B
L Control
2.09 Max
.05
0
Coil must be selected separately. See page 248.
.58
2.50
2.91 Max
T
T
D
B
t
b
p
P
a
FDCB
Shown
T
B
P
.86
3.42 3.98
3.86
2.94
Assembly
Model Code*
X4DD-LAN-CA
SOLENOID VALVE
METER-OUT B
A
Function
Meter-In A, Solenoid Normally Closed
Meter-Out B, Solenoid Normally Closed
.34
0
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
SOLENOID VALVE
METER-IN A
L Control
2.09 Max
0
.05
Coil must be selected separately. See page 248.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 110 for cartridge models NF*C-*** and NC*B-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
172
US Selected Assemblies Catalogue #999-901-192
ISO 05/CETOP 5
with X and Y U.S.
Sandwich Assemblies
ISO 05 / CETOP 5 WITH X AND Y RELIEF VALVES
(SIDE PORTED SUBPLATE)
T-10A Cavity
All subplates shown
below are 4.5” wide
X
Y
PILOT OPERATED
DIRECT ACTING
ISO5/CETOP VERSION
x p
t
b
a
Function
y
X
P
P to T
Y
0
A
B
T
Ports
X, Y
Assembly
Model Code*
1/2” NPTF
3/4” NPTF
SAE-10
SAE-12
1/4” NPTF
1/4” NPTF
SAE-6
SAE-6
RPEC-LAN-ZHP
RPEC-LAN-ZHQ
RPEC-LAN-ZHR
RPEC-LAN-ZHS
0
.44
P
x
Ports
A, B, P, T
0 .88 1.56
3.56
p
a
b
X t
T
y
Y
.31
2.22
t
B
A
4.06
4.50
Order Retainer and Seal Kits
separately. (See page 141)
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
Ports
A, B, P, T
Ports
X, Y
Assembly
Model Code*
1/2” NPTF
3/4” NPTF
SAE-10
SAE-12
1/4” NPTF
1/4” NPTF
SAE-6
SAE-6
RDDA-LAN-ZHP
RDDA-LAN-ZHQ
RDDA-LAN-ZHR
RDDA-LAN-ZHS
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
U.S. D05H VERSION
Function
P to T
x p
t
b
a
X
P
y
Y
0
1.00
A
B
T
Assembly
Model Code*
1/2” NPTF
3/4” NPTF
SAE-10
SAE-12
1/4” NPTF
1/4” NPTF
SAE-6
SAE-6
RPEC-LAN-ZHH
RPEC-LAN-ZHJ
RPEC-LAN-ZHK
RPEC-LAN-ZHL
1.56
X
x 1.31
p
a
Ports
X, Y
0 .88
0
.44
P
t
Ports
A, B, P, T
3.56
b
t
B
2.22
y
T
A
4.06
Y
4.50
1.81
Order Retainer and Seal Kits
separately. (See page 141)
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
Ports
A, B, P, T
Ports
X, Y
Assembly
Model Code*
1/2” NPTF
3/4” NPTF
SAE-10
SAE-12
1/4” NPTF
1/4” NPTF
SAE-6
SAE-6
RDDA-LAN-ZHH
RDDA-LAN-ZHJ
RDDA-LAN-ZHK
RDDA-LAN-ZHL
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the
differences in the European and U.S. seal plates. To order seal plates separately see page 141-142.
Go to www.sunhydraulics.com for more product information and pricing.
US Selected Assemblies Catalogue #999-901-192
173
ISO 05/CETOP 5
with X and Y U.S.
Sandwich Assemblies
ISO 05 / CETOP 5 WITH X AND Y RELIEF VALVES
T-3A / T-10A Cavities
p
t
b
a
All sandwich bodies
shown below are 2.50” wide
Y
PILOT OPERATED
x
X
DIRECT ACTING
Function
Gauge Port
1/4” NPTF
y
1.94
P to T (High Capacity)
SOLENOID
VALVE
G
X P
T
B
A
Y
0
Assembly
Model Code*
L Control
2.47
.88
Max.
Order Retainer and Seal Kits
separately. (See page 141)
3.62
RPGC-LAN-CJP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
b
t
a
B
T
Y
A
0
.05
Assembly
Model Code*
L Control
3.62
2.47
.88
Max.
Order Retainer and Seal Kits
separately. (See page 141)
RPGC-LAN-CJA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
x
b
t
a
B
T
Assembly
Model Code*
L Control
3.62
2.47
.88
Max.
Order Retainer and Seal Kits
separately. (See page 141)
RPGC-LAN-CJB
p
t
B to T (High Capacity)
Assembly
Model Code*
.05
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
Y
A
RDFA-LAN-CJA
SOLENOID
VALVE
G
P
Assembly
Model Code*
Function
Gauge Port
1/4” NPTF
y
1.94
X
A to T (High Capacity)
SOLENOID
VALVE
G
P
RDFA-LAN-CJP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
Gauge Port
1/4” NPTF
y
1.94
X
Assembly
Model Code*
.05
b
a
y
1.44
RDFA-LAN-CJB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
A and B to T (High Capacity)
SOLENOID
VALVE
0
X P
T
B
A
Y
.05
L Control
2.47
Max.
Assembly
Model Code*
RPGC-LAN-CJX
3.62
.69
.69
Order Retainer and Seal Kits
separately. (See page 141)
L Control
2.47
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
t
b
a
y
Assembly
Model Code*
RDFA-LAN-CJX
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.44
Function
SOLENOID
VALVE
A to B and B to A
(Cross-port)
0
X P
T
B
A Y
.05
Assembly
Model Code*
RPEC-LAN-CJY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
L Control
L Control
2.12
2.12
3.62
Max.
Max.
Order Retainer and Seal Kits
separately. (See page 141)
Assembly
Model Code*
RDDA-LAN-CJY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the
differences in the European and U.S. seal plates. To order seal plates separately see page 141-142.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
174
US Selected Assemblies Catalogue #999-901-192
ISO 05 / CETOP 5 WITH X AND Y SEQUENCE VALVES
T-2A Cavity
X
Y
PILOT OPERATED
x
p
t
b
All sandwich bodies
shown below are 2.50” wide
a
DIRECT ACTING
Gauge Port
1/4” NPTF
y
2.44
Function
In to P
SOLENOID
VALVE
G
P
T
B
A
Y
.05
Assembly
Model Code*
RSFC-LAN-BJW
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
t
b
0
a
y
2.44
T
B
A
Assembly
Model Code*
RSFC-LAN-BJ4
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
t
b
a
0
Y
y
T
B
A
CXED-XAN
SOLENOID
VALVE
SEQUENCE INTO A
.05
L Control
1.93
3.62
Max.
.78 .62
Order Retainer and Seal Kits
separately. (See page 141)
2.44
SOLENOID
VALVE
SEQUENCE INTO B
CXED-XAN
0
X P
SXEA-LAN-BJW
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
In to A (Reverse Free Flow Check)
Out of B (Reverse Free Flow Check)
Assembly
Model Code*
SXEA-LAN-BJ4
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
In to B (Reverse Free Flow Check)
Out of A (Reverse Free Flow Check)
SOLENOID
VALVE
SEQUENCE OUT A
X P
Assembly
Model Code*
L Control
3.62
2.06
Max. .19
Order Retainer and Seal Kits
separately. (See page 141)
SOLENOID
VALVE
SEQUENCE OUT B
X
Y
.05
Assembly
Model Code*
RSFC-LAN-BJ5
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
L Control
1.93
3.62
Max.
.62 .78
Order Retainer and Seal Kits
separately. (See page 141)
Assembly
Model Code*
SXEA-LAN-BJ5
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 20 for cartridge models RS*C-*** and SX*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the
differences in the European and U.S. seal plates. To order seal plates separately see page 141-142.
Go to www.sunhydraulics.com for more product information.
US Selected Assemblies Catalogue #999-901-192
175
ISO 05/CETOP 5
with X and Y U.S.
Sandwich Assemblies
ISO 05/CETOP 5
with X and Y U.S.
Sandwich Assemblies
ISO 05 / CETOP 5 WITH X AND Y REDUCING VALVES
T-2A Cavity
Y
PILOT OPERATED
x
t
p
b
T
P
B
A
Function
Gauge Port
1/4” NPTF
y
a
2.44
G
X
All sandwich bodies
shown below are 2.50” wide
X
On P Drained to T
SOLENOID
VALVE
Y
0
Assembly
Model Code*
.05
L Control
2.06
Max.
.19
Order Retainer and Seal Kits
separately. (See page 141)
PBFB-LAN-BJP
3.62
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
Function
Gauge Port
1/4” NPTF
y
2.44
On A Drained to B
SOLENOID
VALVE
G
X
P
T
B
A
Y
0
Assembly
Model Code*
PBFB-LAN-BJA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
.05
L Control
3.62
1.81
Max.
Order Retainer and Seal Kits
separately. (See page 141)
Function
Gauge Port
1/4” NPTF
y
a
2.44
On B Drained to A
SOLENOID
VALVE
G
X
P
T
B
Y
A
0
Assembly
Model Code*
.05
L Control
2.06
Max.
.19
Order Retainer and Seal Kits
separately. (See page 141)
3.62
PBFB-LAN-BJB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
y
2.44
Function
SOLENOID
VALVE
On A Drain to T
(Reverse Free Flow Check)
CXFA
X
P
T
B
A
0
Y
.05
L Control
3.62
1.93
.78 .62
Max.
Order Retainer and Seal Kits
separately. (See page 141)
Assembly
Model Code*
PBFB-LAN-BJ2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
Function
2.44
y
SOLENOID
VALVE
CXFA
X
P
T
B
A
Y
Assembly
Model Code*
PBFB-LAN-BJ3
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
On B Drain to T
(Reverse Free Flow Check)
0
.05
L Control
3.62
1.93
.78
.62
Max.
Order Retainer and Seal Kits
separately. (See page 141)
Page 34 for cartridge models PB*B-*** and page 102 for CX*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the
differences in the European and U.S. seal plates. To order seal plates separately see page 141-142
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
176
US Selected Assemblies Catalogue #999-901-192
ISO 05 / CETOP 5 WITH X AND Y REDUCING / RELIEVING VALVES
T-2A Cavity
Y
PILOT OPERATED
x
p
b
t
G
X
P
B
T
A
DIRECT ACTING
Function
On P Tank to T Drained to T
Gauge Port
1/4” NPTF
y
a
All sandwich bodies
shown below are 2.50” wide
X
2.44
SOLENOID
VALVE
Y
0
Assembly
Model Code*
.05
PPFB-LAN-BJP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
Assembly
Model Code*
L Control
2.06
Max.
.19
Order Retainer and Seal Kits
separately. (See page 141)
3.62
PRFB-LAN-BJP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
y
Gauge Port
1/4” NPTF
2.44
On A Tank to B
SOLENOID
VALVE
G
X P
T
B
A
Y
0
Assembly
Model Code*
PPFB-LAN-BJA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
.05
L Control
3.62
1.81
Max.
Order Retainer and Seal Kits
separately. (See page 141)
Assembly
Model Code*
PRFB-LAN-BJA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
y
Gauge Port
1/4” NPTF
On B Tank to A
2.44
SOLENOID
VALVE
G
X P
T
B
A
Y
0
Assembly
Model Code*
.05
PPFB-LAN-BJB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
Assembly
Model Code*
L Control
2.06
Max.
Order Retainer and Seal Kits
separately. (See page 141)
3.62
y
PRFB-LAN-BJB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
2.44
SOLENOID
VALVE
On A Tank to T
(Reverse Free Flow Check)
CXFA
X
P
T
B
A
Assembly
Model Code*
PPFB-LAN-BJ2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
0
Y
.05
L Control
3.62
1.93
.78 .62
Max.
Order Retainer and Seal Kits
separately. (See page 141)
P
T
B
A
Y
Assembly
Model Code*
PPFB-LAN-BJ3
PRFB-LAN-BJ2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
y
2.44
SOLENOID
VALVE
CXFA
X
Assembly
Model Code*
On B Tank to T
(Reverse Free Flow Check)
0
.05
L Control
1.93
.62 .78
Max.
Order Retainer and Seal Kits
separately. (See page 141)
3.62
Assembly
Model Code*
PRFB-LAN-BJ3
*Add modifier /S to order Ductile Iron for pressure
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
rating over 3000 psi.
NOTES: Page 34 for cartridge models PPFB-*** and PRFB-***, and page 102 for C*FA-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the
differences in the European and U.S. seal plates. To order seal plates separately see page 141-142.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
177
ISO 05/CETOP 5
with X and Y U.S.
Sandwich Assemblies
ISO 05/CETOP 5
with X and Y U.S.
Sandwich Assemblies
ISO 05 / CETOP 5 WITH X AND Y COUNTERBALANCE VALVES
T-2A Cavity
All sandwich bodies
shown below are 2.50” wide
X
PILOT RATIOS
3:1, 1.5:1 and 2:1
PILOT RATIOS
2.3:1, 4.5:1 and 10:1
Y
Function
x
p
t
b
a
Gauge Port
1/4” NPTF
y
2.44
On A Pilot from B
SOLENOID
VALVE
G
X
P
T
B
A
Y
0
Assembly
Model Code*
Assembly
Model Code*
.05
L Control
1.38
3.62
Max.
Order Retainer and Seal Kits
separately. (See page 141)
CBE*-LHN-BJA
*The 4th digit of the Model Code must be entered to
specify counterbalance pilot ratio. Add modifier /S to
order Ductile Iron for pressure rating over 3000 psi.
CBE*-LJN-BJA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
x
p
t
b
Gauge Port
1/4” NPTF
y
a
2.44
On B Pilot from A
SOLENOID
VALVE
G
X P
T
B
Y
A
0
Assembly
Model Code*
.05
CBE*-LHN-BJB
*The 4th digit of the Model Code must be entered to
specify counterbalance pilot ratio. Add modifier /S to
order Ductile Iron for pressure rating over 3000 psi.
Assembly
Model Code*
L Control
1.63
3.62
Max.
Order Retainer and Seal Kits
separately. (See page 141)
CBE*-LJN-BJB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
x
p
t
b
a
y
2.44
On A and B (Cross-Piloted)
SOLENOID
VALVE
X P
T
B
A
Y
0
Assembly
Model Code*
CBE*-LHN-BJY
*The 4th digit of the Model Code must be entered to
specify counterbalance pilot ratio. Add modifier /S to
order Ductile Iron for pressure rating over 3000 psi.
x p
t
b
a
y
.05
L Control
L Control
1.65
3.62
1.65
.88
Max. .88
Max.
Order Retainer and Seal Kits
separately. (See page 141)
X P
T
B
A
Y
Assembly
Model Code*
CBE*-LHN-BJ8
*The 4th digit of the Model Code must be entered to
specify counterbalance pilot ratio. Add modifier /S to
order Ductile Iron for pressure rating over 3000 psi.
CBE*-LJN-BJY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
2.94
SOLENOID
VALVE
CXFC
Assembly
Model Code*
CXFC
Cushion Lock Circuit
On A and B
0
.05
L Control
3.62
1.66
.95
Max. .95
Order Retainer and Seal Kits
separately. (See page 141)
L Control
1.66
Max.
Assembly
Model Code*
CBE*-LJN-BJ8
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 50 for cartridge model CBE*-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the
differences in the European and U.S. seal plates. To order seal plates separately see page 141-142.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
178
US Selected Assemblies Catalogue #999-901-192
ISO 05 / CETOP 5 WITH X AND Y PILOT-TO-OPEN CHECK VALVES
T-2A Cavity
X
Y
PILOT OPERATED
x
p
b
t
a
All sandwich bodies
shown below are 2.50” wide
Gauge Port
1/4” NPTF
y
2.44
Function
On A Pilot from B
SOLENOID
VALVE
G
X
P
T
B
A
Y
0
.05
Assembly
Model Code*
3.62
.38
Max.
X Control
Order Retainer and Seal Kits
separately. (See page 141)
CKEB-XCN-BJA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
b
t
a
Function
Gauge Port
1/4” NPTF
y
2.44
On B Pilot from A
SOLENOID
VALVE
G
X
P
B
T
Y
A
0
.05
Assembly
Model Code*
3.62
.63
Max.
X Control
Order Retainer and Seal Kits
separately. (See page 141)
CKEB-XCN-BJB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
2.44
x
p
t
b
a
y
X
P
T
B
A
Y
SOLENOID
VALVE
On A and B (Cross-Piloted)
0
.05
Assembly
Model Code*
CKEB-XCN-BJY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3.62
.88 .65
.65 .88
Max.
Max.
X Control
X Control
Order Retainer and Seal Kits
separately. (See page 141)
NOTES: Page 78 for cartridge models CK**-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the
differences in the European and U.S. seal plates. To order seal plates separately see page 141-142.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
179
ISO 05/CETOP 5
with X and Y U.S.
Sandwich Assemblies
ISO 05 / CETOP 5 WITH X AND Y CHECK VALVES
T-5A Cavity
X
All sandwich bodies
shown below are 2.50” wide
Y
CHECK VALVES
Function
2.44
x
p
t
b
a
y
X
P
T
B
A
Y
SOLENOID
VALVE
On P
0
.05
3.62
Assembly
Model Code*
.378
Max.
Order Retainer and Seal Kits
separately. (See page 141)
CXFA-XCN-DJP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
t
b
a
y
2.44
SOLENOID
VALVE
B
Function
On A Free Flow Out of Valve
On B Free Flow Into Valve
0
T
B
A
Y
.05
Assembly
Model Code*
CXFA-XCN-DJK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
t
b
a
3.62
.658 .22
Max.
Order Retainer and Seal Kits
separately. (See page 141)
2.44
y
0
X P
T
B
A
SOLENOID
VALVE
A
On A Free Flow Into Valve
.05
Y
3.62
Assembly
Model Code*
.22 .658
Max.
Order Retainer and Seal Kits
separately. (See page 141)
CXFA-XCN-DJJ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
2.44
x
Function
On B Free Flow Out of Valve
SOLENOID
VALVE
B
X P
SOLENOID
VALVE
A
ISO 05/CETOP 5
with X and Y U.S.
Sandwich Assemblies
p
t
b
a
y
X P
T
B
A
Y
SOLENOID
VALVE
T to A and B
0
.05
Assembly
Model Code*
CXFA-XAN-DJW
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3.62
.658 .50
.50 .658
Max.
Max.
Order Retainer and Seal Kits
separately. (See page 141)
NOTES: Page 102 for cartridge models CX*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the
differences in the European and U.S. seal plates. To order seal plates separately see page 141-142.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
180
US Selected Assemblies Catalogue #999-901-192
ISO 05 / CETOP 5 WITH X AND Y FLOW CONTROL VALVES
T-5A Cavity
X
p
t
b
a
y
FULLY ADJUSTABLE PRESSURE
COMPENSATED WITH FREE FLOW CHECK
Y
FULLY ADJUSTABLE NEEDLE
x
All sandwich bodies
shown below are 2.50” wide
Function
2.44
Meter-In P
SOLENOID
VALVE
X P
T
B
A
Y
Note: Free Flow Check with Model FDCB Only
0
.05
Assembly
Model Code*
NFDC-LAN-DJP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
FULLY ADJUSTABLE NEEDLE
WITH FREE FLOW CHECK
x
p
t
b
L Control
2.31
Max.
Order Retainer and Seal Kits
separately. (See page 141)
Assembly
Model Code*
3.62
a
FDCB-LAN-DJP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
2.44
Meter-Out A
SOLENOID
VALVE
y
METER-OUT A
Meter-In B
METER-IN B
X P
T
B
A
Y
SOLENOID
VALVE
0
.05
3.62
Assembly
Model Code*
L Control
2.41
Max.
NCEB-LCN-DJA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
t
b
a
Assembly
Model Code*
.22
Order Retainer and Seal Kits
separately. (See page 141)
y
FDCB-LAN-DJA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
2.44
SOLENOID
VALVE
Meter-In A
METER-OUT B
Meter-Out B
METER-IN A
T
B
A
Y
Assembly
Model Code*
NCEB-LCN-DJB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
t
b
a
y
SOLENOID
VALVE
0
X P
.05
Assembly
Model Code*
L Control
2.41
3.62
Max. .22
Order Retainer and Seal Kits
separately. (See page 141)
FDCB-LAN-DJB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
2.44
SOLENOID
VALVE
Meter-In A and B
METER-OUT A-B
Meter-Out A and B
METER-IN A-B
SOLENOID
VALVE
0
XP
T
B
A
Y
Assembly
Model Code*
NCEB-LCN-DJY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.05
L Control
2.41
Max.
.44
3.62
.44
Order Retainer and Seal Kits
separately. (See page 141)
L Control
2.41
Max.
Assembly
Model Code*
FDCB-LAN-DJY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 110 for cartridge models NF*C-*** and NC*B-***, and page 126 for FD**-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the
differences in the European and U.S. seal plates. To order seal plates separately see page 141-142.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
181
ISO 05/CETOP 5
with X and Y U.S.
Sandwich Assemblies
ISO 05 / CETOP 5 WITH X AND Y FLOW CONTROL VALVES
T-13A Cavity
X
Y
FULLY ADJUSTABLE NEEDLE
.50
t
p
b
a
t
0
Function
Meter A to B and B to A
SOLENOID VALVE A1
SOLENOID VALVE B1
ISO 05/CETOP 5
with X and Y U.S.
Sandwich Assemblies
1.19
Mounting Holes:
.28 diameter through hole. 4 places.
2.50
T
P
B
A
T
T
Assembly
Model Code*
T
B
A
P
.59
NFCC-LCN-DJS
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
3.62
1.81
0
Order Retainer and Seal Kits
separately. (See page 141)
NOTES: Page 110 for cartridge model NF*C-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Sun ISO 05 X, Y, sandwich bodies are furnished with pilot and drain connections. Seal plates are NOT supplied with these bodies, due to the
differences in the European and U.S. seal plates. To order seal plates separately see page 141-142.
Go to www.sunhydraulics.com for more product information.
182
US Selected Assemblies Catalogue #999-901-192
ISO 07 / CETOP 7 RELIEF VALVES
(SIDE PORTED SUBPLATE / SIDE PORTED SUBPLATE WITH GASKET MOUNTED
TANK PORT)
T-3A Cavity
All subplates shown
below are 5.0” wide
X
Y
PILOT OPERATED
DIRECT ACTING
Function
y p
t
a
b
x
T
Y
P
X
G
B
A
T
Ports
A, B, P, T
Ports
X, Y
Assembly
Model Code*
3/4” NPTF
SAE-12
1/4” NPTF
SAE-6
RPGC-LAN-ZLW
RPGC-LAN-ZLX
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
X
P
P to T
1.94
1.28
0
3.78 2.03 .56 0
1/4” NPTF Gauge Port
0
0
T
P
.62
p
t
x
1.75
2.37
a
b
2.74
y
B
A
4.00
5.00 3.65 1.90 .44 0
0
Ports
A, B, P, T
Ports
X, Y
Assembly
Model Code*
3/4” NPTF
SAE-12
1/4” NPTF
SAE-6
RDFA-LAN-ZLW
RDFA-LAN-ZLX
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
Function
t
a
b
X
T
P
y
T
P
X
Y
T
Ports
A, B, P, T
Ports
X, Y
Assembly
Model Code*
3/4” NPTF
SAE-12
1/4” NPTF
SAE-6
RPGC-LAN-VTE
RPGC-LAN-VTF
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
5.00 3.78 2.03 .56 0
Gasket Mount 1/4” NPTF Gauge Port
T Port
0
0
P
T
.63
0
T
P
1.75
2.38
B
A
x
B
A
2.44
1.28
.94
0
y
x p
A
5.00
B
3.66 1.91 .44
4.00
P to T
Ports
A, B, P, T
Ports
X, Y
Assembly
Model Code*
3/4” NPTF
SAE-12
1/4” NPTF
SAE-6
RDFA-LAN-VTE
RDFA-LAN-ZLF
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information and pricing.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
183
ISO 07/CETOP 7
Sandwich Assemblies
ISO 07/CETOP 7
Sandwich Assemblies
ISO 07 / CETOP 7 RELIEF VALVES
T-3A / T-10A Cavities
Y
PILOT OPERATED
x
p
t
b
a
All sandwich bodies
shown below are 3.50” wide
X
DIRECT ACTING
Gauge Port
1/4” NPTF
y
Function
P to T
1.88
0
G
X P
T
B
A
.08
(4) – 118 O–rings
Assembly
Model Code*
RPGC-LAN-CKP
p
b
t
a
(2) – 111 O–rings
Assembly
Model Code*
4.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
.25
Y
RDFA-LAN-CKP
L Control
2.47
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
y
Gauge Port
1/4” NPTF
1.88
Function
A to T
G
0
X
P
B
T
Y
A
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
RPGC-LAN-CKA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
x
b
t
a
2.47
Max. .47
L Control
(2) – 111 O–rings
Assembly
Model Code*
4.75
RDFA-LAN-CKA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
y
Gauge Port
1/4” NPTF
1.88
Function
B to T
G
0
X
P
B
T
Y
A
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
RPGC-LAN-CKB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
y
X P
T
B
A
Y
L Control
2.47
Max.
Assembly
Model Code*
(2) – 111 O–rings
RDFA-LAN-CKB
4.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
A and B to T (High Capacity)
2.66
0
Assembly
Model Code*
RPGC-LAN-CKX
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
t
b
.25
.08
(4) – 118 O–rings
a
y
L Control
2.47
Max. .50
(2) – 111 O–rings
4.75
L Control
2.47
.50 Max.
Assembly
Model Code*
RDFA-LAN-CKX
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
1.88
A to B and B to A
(Cross-port)
0
.25
X P
T
B
A Y
Assembly
Model Code*
RPEC-LAN-CKY
.08
(4) – 118 O–rings
(2) – 111 O–rings
4.75
1.59
Max.
L Control
1.59
Max.
L Control
Assembly
Model Code*
RDDA-LAN-CKY
*Add modifier /S to order Ductile Iron for pressure
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
rating over 3000 psi.
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
184
US Selected Assemblies Catalogue #999-901-192
ISO 07/CETOP 7
Sandwich Assemblies
ISO 07 / CETOP 7 SEQUENCE VALVES
T-17A Cavity
Y
PILOT OPERATED
x
p
t
b
Function
Gauge Port
1/4” NPTF
y
a
All sandwich bodies
shown below are 3.50” wide
X
In to P
2.66
G
X
P
T
B
A
0
Y
.25
Assembly
Model Code*
.08
(4) – 118 O–rings
(2) – 111 O–rings
RSHC-LAN-BKW
L Control
4.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
2.37
.75 Max.
Function
In to A (Reverse Free Flow Check)
y
2.66
CXGD-XCN
X P
T
B
A
Y
0
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
RSHC-LAN-BK4
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
(2) – 111 O–rings
L Control
2.37
Max. 1.41
4.75
.94
Function
In to B (Reverse Free Flow Check)
y
2.66
CXGD-XCN
X P
T
B
A
Y
0
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
RSHC-LAN-BK5
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
L Control
2.37
Max. .16
(2) – 111 O–rings
4.75
1.09 .94
Function
Out of A (Reverse Free Flow Check)
y
2.66
CXGD-XCN
X
P
T
B
A
Y
RSHC-LAN-BK6
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
x
0
a
y
(2) – 111 O–rings
L Control
2.37
Max. 1.41
4.75
.94
Function
Out of B (Reverse Free Flow Check)
2.66
CXGD-XCN
0
X
P
T
B
A
.25
Y
Assembly
Model Code*
RSHC-LAN-BK7
.08
(4) – 118 O–rings
(2) – 111 O–rings
L Control
4.75
.94 .16
1.09
2.37
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 20 for cartridge model RS*C-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
185
ISO 07/CETOP 7
Sandwich Assemblies
ISO 07 / CETOP 7 REDUCING VALVES
T-17A Cavity
All sandwich bodies
shown below are 3.50” wide
X
Y
PILOT OPERATED
x
t
p
b
a
y
G
X
T
P
B
A
Function
Gauge Port
1/4” NPTF
On P Drained to T
2.66
Y
0
.25
.08
Assembly
Model Code*
(4) – 118 O–rings
(2) – 111 O–rings
PBHB-LAN-BKP
x
p
t
b
a
y
X
P
T
B
A
Y
L Control
2.37
Max.
4.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.75
Function
2.66
On A Drained to B
0
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
(2) – 111 O–rings
L Control
PBHB-LAN-BKA
2.37 .97
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
y
X
P
T
B
A
Y
4.75
Function
2.66
On B Drained to A
0
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
PBHB-LAN-BKB
(2) – 111 O–rings
L Control
2.37
.91 Max.
4.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
y
Function
2.66
On A Drain to T
(Reverse Free Flow Check)
CXHA-XCN
0
X
P
T
B
A
.08
(4) – 118 O–rings
Assembly
Model Code*
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
(2) – 111 O–rings
L Control
PBHB-LAN-BK2
x
.25
Y
a
y
2.37
Max.
1.41
4.75
.78
Function
2.66
CXHA-XCN
On B Drain to T
(Reverse Free Flow Check)
0
X
P
T
B
A
Assembly
Model Code*
PBHB-LAN-BKJ
.25
Y
.08
(4) – 118 O–rings
(2) – 111 O–rings
L Control
2.37
Max. .16
4.75
1.09 .94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 34 for cartridge model PB*B-*** and page 102 for CX*A-*** shows performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
186
US Selected Assemblies Catalogue #999-901-192
ISO 07 / CETOP 7 REDUCING / RELIEVING VALVES
T-17A Cavity
Y
PILOT OPERATED
x
p
b
t
a
P
B
T
A
DIRECT ACTING
Function
On P Tank to T Drained to T
Gauge Port
1/4” NPTF
y
G
X
All sandwich bodies
shown below are 3.50” wide
X
2.66
Y
0
.25
Assembly
Model Code*
.08
(4) – 118 O–rings
(2) – 111 O–rings
PPHB-LAN-BKP
x
p
t
b
a
y
X P
T
B
A
Y
L Control
3.02
.75 Max.
4.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Assembly
Model Code*
PRHB-LAN-BKP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
On A Tank to B Drained to B
2.66
0
Assembly
Model Code*
PPHB-LAN-BKA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
.25
.08
(4) – 118 O–rings
p
t
b
a
y
X P
T
B
A
Y
L Control
3.02
Max. .97
(2) – 111 O–rings
Assembly
Model Code*
PRHB-LAN-BKA
4.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
On B Tank to A Drained to A
2.66
0
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
PPHB-LAN-BKB
(2) – 111 O–rings
L Control
3.02
Max.
.91
4.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
Assembly
Model Code*
PRHB-LAN-BKB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
On A Tank to T Drained to T
(Reverse Free Flow Check)
y
2.66
CXHA-XCN
X
P
T
B
A
Y
PPHB-LAN-BK2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
t
b
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
x
0
a
y
L Control
3.02
Max. 1.41
(2) – 111 O–rings
Assembly
Model Code*
PRHB-LAN-BK2
4.75
.78
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
On B Tank to T Drained to T
(Reverse Free Flow Check)
2.66
CXHA-XCN
X
P
T
B
A
Y
Assembly
Model Code*
PPHB-LAN-BKJ
0
.25
.08
(4) – 118 O–rings
(2) – 111 O–rings
L Control
3.02
Max.
.16
4.75
Assembly
Model Code*
PRHB-LAN-BKJ
1.09 .94
*Add modifier /S to order Ductile Iron for pressure
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
rating over 3000 psi.
NOTES: Page 42 for cartridge models PP*B-*** and PR*B-***, and page 102 for CX*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
187
ISO 07/CETOP 7
Sandwich Assemblies
ISO 07/CETOP 7
Sandwich Assemblies
ISO 07 / CETOP 7 COUNTERBALANCE VALVES
T-17A Cavity
All sandwich bodies
shown below are 3.50” wide
X
PILOT RATIOS
3:1, 2:1 and 1.5:1
PILOT RATIOS
2.3:1, 4.5:1 and 10:1
Y
Function
x
p
t
b
a
y
X
P
T
B
A
Y
On A Pilot from B
2.66
0
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
(2) – 111 O–rings
Assembly
Model Code*
L Control
CBG*-LHN-BKA
4.75
1.84 .97
Max.
CBG*-LJN-BKA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
x
p
t
b
a
y
T
B
A
Y
On B Pilot from A
2.66
0
.25
X P
.08
(4) – 118 O–rings
Assembly
Model Code*
(2) – 111 O–rings
CBG*-LHN-BKB
.91
p
t
b
a
y
X P
T
B
A
Y
CBG*-LJN-BKB
1.84
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
Assembly
Model Code*
L Control
4.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
2.66
On A and B (Cross-piloted)
0
Assembly
Model Code*
CBG*-LHN-BKY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.25
.08
(4) – 118 O–rings
(2) – 111 O–rings
L Control
L Control
1.84 1.44
Max.
4.75
1.37 1.84
Max.
Assembly
Model Code*
CBG*-LJN-BKY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 50 for cartridge model CB**-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
188
US Selected Assemblies Catalogue #999-901-192
ISO 07 / CETOP 7 PILOT-TO-OPEN CHECK VALVES
T-17A Cavity
All sandwich bodies
shown below are 3.50” wide
X
Y
PILOT OPERATED
Function
x
p
t
b
a
y
On A Pilot from B
2.66
X
P
T
B
A
0
Y
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
(2) – 111 O–rings
L Control: 2.37 Max.
CKGB-XCN-BKA
4.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.97
Function
x
p
t
b
a
y
X
P
T
B
A
Y
On B Pilot from A
2.66
0
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
(2) – 111 O–rings
L Control: 2.37 Max.
CKGB-XCN-BKB
4.75
.91
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
x
p
t
b
a
y
X
P
T
B
A
Y
On A and B (Cross-piloted)
2.66
0
Assembly
Model Code*
CKGB-XCN-BKY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.25
.08
(4) – 118 O–rings
(2) – 111 O–rings
4.75
1.37 .90
Max.
X Control
.90 1.44
Max.
X Control
NOTES: Page 78 for cartridge model CK**-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
189
ISO 07/CETOP 7
Sandwich Assemblies
ISO 07/CETOP 7
Sandwich Assemblies
ISO 07 / CETOP 7 CHECK VALVES
T-5A/T-16A Cavity
All sandwich bodies
shown below are 3.50” wide
X
Y
CHECK VALVE
Function
x
p
t
b
a
y
X
P
T
B
A
Y
2.66
On P
0
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
(2) – 111 O–rings
4.75
CXHA-XCN-DKP
.47 .94
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
y
X
P
T
B
A
Y
Function
On T Free Flow Out of Valve
2.66
0
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
CXHA-XCN-DKT
.94 1.78
Max.
(2) – 111 O–rings
4.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
t
a
p
b
x y
T
A
P
B
X Y
1.88
T to A and B
0
.09
.08
(4) – 118 O–rings
Assembly
Model Code*
(2) – 111 O–rings
3.50
CXFA-XAN-DKX
.94
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
y
X
P
T
B
A
Y
Function
On A and B, Free Flow Out of Valve
2.66
0
Assembly
Model Code*
CXHA-XCN-DKZ
.25
.08
(4) – 118 O–rings
(2) – 111 O–rings
4.75
.94 1.16
Max.
1.16 .94
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 102 for cartridge models CX*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
190
US Selected Assemblies Catalogue #999-901-192
ISO 07 / CETOP 7 FLOW CONTROL VALVES
T-16A Cavity
p
t
b
a
y
FULLY ADJUSTABLE PRESSURE
COMPENSATED WITH FREE FLOW CHECK
Y
FULLY ADJUSTABLE NEEDLE
x
All sandwich bodies
shown below are 3.50” wide
X
Function
2.66
Meter-In P
0
X
.25
P
T
B
A
Y
Note: Free Flow Check on FDEA Only
.08
(4) – 118 O–rings
(2) – 111 O–rings
Assembly
Model Code*
NFEC-LEN-DKP
L Control
2.63
Max.
.47
4.75
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
FULLY ADJUSTABLE NEEDLE
WITH FREE FLOW CHECK
Assembly
Model Code*
FDEA-LAN-DKP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
2.66
p
x
t
b
a
Meter-Out A
y
0
.25
X
P
T
B
A
Y
.08
(4) – 118 O–rings
(2) – 111 O–rings
L Control
2.63
Max. 1.16
Assembly
Model Code*
NCFB-L*N-DKA
Assembly
Model Code*
4.75
FDEA-LAN-DKA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
2.66
y
Meter-Out B
0
X
P
T
B
A
.25
Y
.08
(4) – 118 O–rings
(2) – 111 O–rings
Assembly
Model Code*
NCFB-L*N-DKB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
t
b
a
y
X P
T
B
A
Y
Assembly
Model Code*
L Control
2.63
1.09 Max.
4.75
FDEA-LAN-DKB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
2.66
Meter-Out A and B
0
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
(2) – 111 O–rings
L Control
4.75
NCFB-L*N-DKY
Max. 1.16
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
t
b
a
y
X P
T
B
A
Y
L Control
2.63
1.09 Max.
Assembly
Model Code*
FDEA-LAN-DKY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
2.66
Meter-In A and B
0
Assembly
Model Code*
NCFB-L*N-DKZ
.25
.08
(4) – 118 O–rings
(2) – 111 O–rings
L Control
4.75
Max. 1.16
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
L Control
2.63
1.09 Max.
Assembly
Model Code*
FDEA-LAN-DKZ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Page 110 for cartridge models NF*C-*** and NC*B-***, and page 126 for FD*A show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
191
ISO 07/CETOP 7
Sandwich Assemblies
ISO 07/CETOP 7
Sandwich Assemblies
ISO 07 / CETOP 7 CIRCUIT SAVER VALVES
(PRESSURE COMPENSATOR / REGENERATIVE)
T-13A Cavity/T-17A Cavity
All sandwich bodies
shown below are 3.50” wide
X
Y
x
p
t
b
a
y
LPHC-XHN
2.66
Ext.
X
P
T
B
A
Assembly
Model Code*
External
Shuttle Port
YFFF: With Load Sensing Pressure
Compensator (Restrictive)
CSAB-*XN
External
Shuttle Port
Y
0
.25
.08
(4) – 118 O–rings
(2) – 111 O–rings
YFFE-XHN-AB
None
4.75
YFFF-XHN-AB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
.75 .91
Max.
SAE-4
x
p
t
b
a
Function
YFFE: Pressure Compensator (Restrictive)
Function
Shuttle A and B (Output External)
y
1.18
1/4” BSPP
Port
0
X
P
T
B
A
Y
(4) – 118 O–rings
Assembly
Model Code*
.25
(2) – 111 O–rings
4.75
.25
Max.
CSAA-BXN-DKS
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
x
p
t
b
a
y
2.66
B to A Regenerative
CBGA-LHN
COHA-XEN
0
X
P
T
B
A
Y
.25
.08
(4) – 118 O–rings
Assembly
Model Code*
(2) – 111 O–rings
L Control
4.75
YDFG-LHN-AB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.37
.91 .22
1.84
Max.
Function
x
p
t
b
a
y
X
P
T
B
A
Y
COHA-XEN
2.66
A to B Regenerative
0
Assembly
Model Code*
YDFE-LHN-AB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
CBGA-LHN
.25
.08
(4) – 118 O–rings
(2) – 111 O–rings
L Control
1.84 1.44
Max.
4.75
.16 .91
NOTES: Page 50 for cartridge model CB*A-*** shows performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
192
US Selected Assemblies Catalogue #999-901-192
ISO 08 / CETOP 8 RELIEF VALVES
(SIDE PORTED SUBPLATE / REAR PORTED SUBPLATE / SIDE PORTED SUBPLATE WITH
GASKET MOUNTED TANK PORT)
T-3A Cavity
All subplates shown
below are 5.94” wide
Y
X
PILOT OPERATED
DIRECT ACTING
Function
x
p
t
b
a
y
G
Y
A
B
X
P
T
P to T (Side Ports)
5.94
3.34
.47
t
Ports
A, B, P, T
Ports
X, Y
Assembly
Model Code*
1” NPTF
SAE-16
1/4” NPTF
SAE-6
RPGC-LAN-CSE
RPGC-LAN-CSM
L Control
1.64
5.94
p
a
x
0
Y
y
1.81
1.12
.44
0
b
X
4.38
2.50
Gauge Port
1/4” NPTF
4.50
4.06
.41 0
.91 0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
Ports
A, B, P, T
Ports
X, Y
Assembly
Model Code*
1” NPTF
SAE-16
1/4” NPTF
SAE-6
RDFA-LAN-CSE
RDFA-LAN-CSM
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
Function
x
p
t
b
a
y
3.44
G
t
X P
T
B
A
p
y
Y
1.81
Ports
X, Y
Assembly
Model Code*
1” NPTF
SAE-16
1/4” NPTF
SAE-6
RPGC-LAN-CRE
RPGC-LAN-CRM
5.94
a
x
L Control
1.64
Ports
A, B, P, T
b
.44
0
4.38
2.50
.41 0
.91 0
Rear Ports
this Face
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
p
t y
b
a
2.38 .88
t
Ports
X, Y
Assembly
Model Code*
1” NPTF
SAE-16
(T) 1” NPTF
1/4” NPTF
SAE-6
RPGC-LAN-CTE
RPGC-LAN-CTM
Ports
X, Y
Assembly
Model Code*
1” NPTF
SAE-16
1/4” NPTF
SAE-6
RDFA-LAN-CRE
RDFA-LAN-CRM
Function
P to T (Gasket Mounted T and Y Port,
Other Ports on Side)
G
X
A
B
Ports
A, B, P, T
Ports
A, B, P, T
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
x
P
P to T (Rear Ports)
Gauge Port
0
1/4” NPTF
4.50
4.06
L Control
1.64
5.94
x
p
a
0
Gauge Port
1/4” NPTF
Y
y
b
X
0
3.56
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
1.44
0
.91
Ports
A, B, P, T
Ports
X, Y
1” NPTF
SAE-16
(T) 1” NPTF
1/4” NPTF
SAE-6
Assembly
Model Code*
RDFA-LAN-CTE
RDFA-LAN-CTM
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information and pricing.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
193
ISO 08/CETOP 8
Sandwich Assemblies
ISO 08/CETOP 8
Sandwich Assemblies
ISO 08 / CETOP 8 RELIEF VALVES
T-16A Cavity
X
PILOT OPERATED
x
p
t
b
a
All sandwich bodies
shown below are 4.50” wide
Y
DIRECT ACTING
Function
y
Gauge Port
1/4” NPTF
P to T (High Capacity)
3.44
G
X P
T
B
A
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
RPIC-LAN-CDO
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
b
t
a
P
B
T
Function
.25
(2) – 114 O–rings
RPIC-LAN-CDC
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
p
b
t
a
P
B
T
RDHA-LAN-CDC
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
RPIC-LAN-CDD
p
t
b
a
y
X P
T
B
A
Y
Assembly
Model Code*
L Control
3.19
Max.
b
a
y
Assembly
Model Code*
RDHA-LAN-CDD
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
A and B to T (High Capacity)
3.44
0
.25
(2) – 114 O–rings
L Control
3.22
Max. .53
RPIC-LAN-CDZ
(4) – 121 O–rings
(4) – 121 O–rings
Assembly
Model Code*
L Control
3.22
Max.
1.47
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
t
B to T (High Capacity)
3.44
.25
(2) – 114 O–rings
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
Assembly
Model Code*
Function
Y
A
(4) – 121 O–rings
Gauge Port
1/4” NPTF
Assembly
Model Code*
x
L Control
3.19
Max.
y
G
X
A to T (High Capacity)
3.44
0
Assembly
Model Code*
x
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Gauge Port
1/4” NPTF
Y
A
RDHA-LAN-CDO
5.94
y
G
X
L Control
3.19
Max.
Assembly
Model Code*
(4) – 121 O–rings
RDHA-LAN-CDZ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
3.44
A to B and B to A
(High Capacity) (Cross-port)
0
X P
T
B
.25
A Y
(2) – 114 O–rings
Assembly
Model Code*
RPIC-LAN-CDW
L Control
3.22
Max.
(4) – 121 O–rings
5.94
L Control
3.22
Max.
Assembly
Model Code*
RDHA-LAN-CDW
*Add modifier /S to order Ductile Iron for pressure
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
rating over 3000 psi.
NOTES: Page 2 for cartridge models RP*C-*** and RD*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
194
US Selected Assemblies Catalogue #999-901-192
ISO 08/CETOP 8
Sandwich Assemblies
ISO 08 / CETOP 8 SEQUENCE VALVES
T-17A Cavity
X
PILOT OPERATED
x
p
t
b
a
All sandwich bodies
shown below are 4.50” wide
Y
Gauge Port
1/4” NPTF
y
3.44
Function
In to P
G
X
P
T
B
A
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
RSHC-LAN-HBW
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
1.75 Max.
y
T
B
A
Function
In to A (Reverse Free Flow Check)
Gauge Port
1/4” NPTF
3.44
G
X P
(4) – 121 O–rings
L
Control
CXHA-XCN
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
RSHC-LAN-HB4
(4) – 121 O–rings
L
Control
5.94
.94 .18
1.68 Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
Function
Out of A (Reverse Free Flow Check)
Gauge Port
1/4” NPTF
y
3.44
CXHA-XAN
G
X
P
T
B
A
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
L
Control
RSHC-LAN-HB6
5.94
p
t
b
a
1.78 Max.
.94 .18
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
(4) – 121 O–rings
y
Function
Out of B (Reverse Free Flow Check)
Gauge Port
1/4” NPTF
3.44
G
X
P
T
B
A
Y
Assembly
Model Code*
RSHC-LAN-HB7
CXHA-XCN
0
.25
(2) – 114 O–rings
(4) – 121 O–rings
L
Control
5.94
.91
1.38 2.34 Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Pages 20 for cartridge models RS*C-*** and page 102 for CX*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
195
ISO 08/CETOP 8
Sandwich Assemblies
ISO 08 / CETOP 8 REDUCING VALVES
T-19A Cavity/T-17A Cavity
PILOT OPERATED
x
t
p
b
a
X
y
G
X
T
P
B
A
All sandwich bodies
shown below are 4.50” wide
Y
Function
On P Drained to T (High Capacity)
Gauge Port
1/4” NPTF
3.44
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
PBJB-LAN-HBO
(4) – 121 O–rings
L Control
2.74
1.72 Max.
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
Function
On A Drained to B (High Capacity)
y
3.44
P
X
T
B
A
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
PBJB-LAN-HBA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
L Control
2.74
Max. 1.72
(4) – 121 O–rings
5.94
Function
On B Drained to A (High Capacity)
y
3.44
X
P
T
B
A
0
.25
(2) – 114 O–rings
Y
Assembly
Model Code*
PBJB-LAN-HBB
(4) – 121 O–rings
5.94
2.65
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
L Control
2.74
Max.
Function
Gauge Port
1/4” NPTF
y
On A Drain to T
(Reverse Free Flow Check)
3.44
CXGD-XCN
G
X
P
T
B
A
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
L Control
PBHB-LAN-HBK
5.94
p
t
b
a
2.47
Max.
.91 .18
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
(4) – 121 O–rings
Function
Gauge Port
1/4” NPTF
y
On B Drain to T
(Reverse Free Flow Check)
3.44
G
X
P
T
B
A
Assembly
Model Code*
PBHB-LAN-HBJ
Y
CXGD-XCN
0
.25
(2) – 114 O–rings
(4) – 121 O–rings
L Control
.91
5.94
1.37 3.02
Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 34 for cartridge model PBJB-*** and page 102 for CX*D-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
196
US Selected Assemblies Catalogue #999-901-192
ISO 08 / CETOP 8 REDUCING / RELIEVING VALVES
T-19A Cavity/T-17A Cavity
PILOT OPERATED
x
p
b
t
a
P
B
T
y
A
DIRECT ACTING
X
Function
On P Tank to T Drained to T
(High Capacity)
Gauge Port
1/4” NPTF
3.44
G
X
All sandwich bodies
shown below are 4.50” wide
Y
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
PPJB-LAN-HBO
(4) – 121 O–rings
5.94
1.72
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
L Control
3.69
Max.
T
B
A
0
Y
.25
(2) – 114 O–rings
Assembly
Model Code*
PPJB-LAN-HBA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
(4) – 121 O–rings
Assembly
Model Code*
L Control
3.69
Max. 1.72
PRJB-LAN-HBA
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
On B Tank to A Drained to A
(High Capacity)
y
3.44
X P
T
B
A
0
.25
(2) – 114 O–rings
Y
Assembly
Model Code*
PPJB-LAN-HBB
(4) – 121 O–rings
5.94
2.65
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
PRJB-LAN-HBO
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
On A Tank to B Drained to B
(High Capacity)
y
3.44
X P
Assembly
Model Code*
L Control
3.69
Max.
PRJB-LAN-HBB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
On A Tank to T Drained to T
(Reverse Free Flow Check)
Gauge Port
1/4” NPTF
y
Assembly
Model Code*
3.44
CXGD-XCN
G
X
P
T
B
A
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
L Control
PPHB-LAN-HBK
5.94
.91 .18
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
(4) – 121 O–rings
2.47
Max.
3.44
G
X
P
T
B
A
Y
Assembly
Model Code*
PPHB-LAN-HBJ
PRHB-LAN-HBK
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
On B Tank to T Drained to T
(Reverse Free Flow Check)
Gauge Port
1/4” NPTF
y
Assembly
Model Code*
CXGD-XCN
0
.25
(2) – 114 O–rings
(4) – 121 O–rings
L Control
.91
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.37 3.02
Max.
Assembly
Model Code*
PRHB-LAN-HBJ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 42 for cartridge model PP*B-*** and PR*B-***, and page 102 for CX*D-*** shows performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
197
ISO 08/CETOP 8
Sandwich Assemblies
ISO 08/CETOP 8
Sandwich Assemblies
ISO 08 / CETOP 8 COUNTERBALANCE VALVES
T-19A Cavity
PILOT RATIOS
3:1, 1.5:1 and 2:1
x
p
t
b
a
Y
All sandwich bodies
shown below are 4.50” wide
PILOT RATIOS
2.3:1, 4.5:1 and 10:1
X
Function
On A Pilot from B (High Capacity)
y
3.44
X
P
T
B
A
0
Y
Assembly
Model Code*
.25
(2) – 114 O–rings
L Control
2.31
Max. 1.72
CBI*-LHN-HBA
(4) – 121 O–rings
Assembly
Model Code*
5.94
CBI*-LJN-HBA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
On B Pilot from A (High Capacity)
y
3.44
X P
T
B
A
0
Y
.25
(2) – 114 O–rings
Assembly
Model Code*
(4) – 121 O–rings
5.94
CBI*-LHN-HBB
2.65
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
Assembly
Model Code*
2.31
Max.
L Control
Function
y
On A and B
(Cross-Piloted) (High Capacity)
3.44
X P
T
B
A
Y
Assembly
Model Code*
CBI*-LHN-HBY
CBI*-LJN-HBB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
.25
(2) – 114 O–rings
L Control
2.31
Max. 1.72
(4) – 121 O–rings
L Control
2.31
2.65
Max.
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Assembly
Model Code*
CBI*-LJN-HBY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 50 for cartridge model CB**-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
198
US Selected Assemblies Catalogue #999-901-192
ISO 08 / CETOP 8 PILOT-TO-OPEN CHECK VALVES
T-19A Cavity
X
PILOT OPERATED
x
p
t
b
a
All sandwich bodies
shown below are 4.50” wide
Y
Function
On A Pilot from B (High Capacity)
y
3.44
X
P
T
B
A
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
CKIB-XCN-HBA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
y
X
P
T
B
A
Y
(4) – 121 O–rings
5.94
1.12 1.72
Max.
X Control
Function
On B Pilot from A (High Capacity)
3.44
0
.25
(2) – 114 O–rings
Assembly
Model Code*
(4) – 121 O–rings
5.94
2.65
1.12
Max.
X Control
CKIB-XCN-HBB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
x
p
t
b
a
y
On A and B
Cross-Piloted (High Capacity)
3.44
X
P
T
B
A
Y
Assembly
Model Code*
CKIB-XCN-HBY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
.25
(2) – 114 O–rings
1.12 1.72
Max.
X Control
5.94
(4) – 121 O–rings
2.65
1.12
Max.
X Control
NOTES: Page 78 for cartridge model CK**-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
199
ISO 08/CETOP 8
Sandwich Assemblies
ISO 08/CETOP 8
Sandwich Assemblies
ISO 08 / CETOP 8 CHECK VALVES
T-18A Cavity/T-16A Cavity
All sandwich bodies
shown below are 4.50” wide
Y
X
CHECK VALVE
Function
x
p
t
b
a
y
X
P
T
B
A
Y
3.44
On P (High Capacity)
0
.25
(2) – 114 O–rings
Assembly
Model Code*
(4) – 121 O–rings
5.94
1.19 1.16
Max.
X Control
CXJA-XCN-IBO
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
x
p
t
b
a
y
On T (High Capacity)
3.44
X
P
T
B
A
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
CXJA-XCN-IBV
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
(4) – 121 O–rings
5.94
1.16 2.12
Max.
X Control
Function
x
p
t
b
a
y
T to A and B
3.44
X P
T
B
A
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
CXHA-XAN-CDV
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
(4) – 121 O–rings
5.94
a
1.16 1.38
Max.
X Control
1.16
Max.
X Control
Function
On A and B Free Flow Out of Valve
(High Capacity)
y
3.44
X
P
T
B
A
Y
Assembly
Model Code*
CXJA-XCN-IBZ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
.25
(2) – 114 O–rings
(4) – 121 O–rings
5.94
2.12
2.16 1.19
Max.
X Control
2.16
Max.
X Control
NOTES: Page 102 for cartridge model CX*A-*** shows performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
200
US Selected Assemblies Catalogue #999-901-192
ISO 08 / CETOP 8 FLOW CONTROL VALVES
T-18A Cavity
All sandwich bodies
shown below are 4.50” wide
Y
FULLY ADJUSTABLE NEEDLE
FULLY ADJUSTABLE PRESSURE
COMPENSATED WITH FREE FLOW CHECK
X
Function
x
p
t
b
a
y
3.44
Meter-In P (High Capacity)
0
X
P
T
B
A
Y
Note: Free Flow Check on FDFA Only
.25
(2) – 114 O–rings
Assembly
Model Code*
(4) – 121 O–rings
L Control
3.28
1.19 Max.
5.94
NFFC-LGN-IBO
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
FULLY ADJUSTABLE NEEDLE
WITH FREE FLOW CHECK
p
x
a
b
t
Assembly
Model Code*
FDFA-LAN-IBO
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
Meter-Out A (High Capacity)
y
3.44
P
X
A
B
T
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
NCGB-LCN-IBE
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
L Control
3.28
Max. 1.19
(4) – 121 O–rings
FDFA-LAN-IBE
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
Meter-Out B (High Capacity)
y
3.44
X
P
T
B
A
Y
0
.25
(2) – 114 O–rings
Assembly
Model Code*
(4) – 121 O–rings
NCGB-LCN-IBF
5.94
2.12
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
t
b
a
L Control
3.28
Max.
T
B
A
Y
NCGB-LCN-IBZ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x p
t
b
a
y
X P
T
B
A
Y
FDFA-LAN-IBF
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
.25
(2) – 114 O–rings
Assembly
Model Code*
Assembly
Model Code*
Function
Meter-In A and B (High Capacity)
y
3.44
X P
Assembly
Model Code*
L Control
3.28
Max. 1.19
5.94
(4) – 121 O–rings
2.12
L Control
3.28
Max.
Assembly
Model Code*
FDFA-LAN-IBZ
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
Meter-Out A and B (High Capacity)
3.44
0
Assembly
Model Code*
NCGB-LCN-IBY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
.25
(2) – 114 O–rings
L Control
3.28
Max. 1.19
5.94
(4) – 121 O–rings
L Control
3.28
Max.
2.12
Assembly
Model Code*
FDFA-LAN-IBY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Page 110 for cartridge model NC*B-*** and page 126 for FD*A-*** show performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
Model Codes printed in red are Preferred Products and are readily available.
US Selected Assemblies Catalogue #999-901-192
201
ISO 08/CETOP 8
Sandwich Assemblies
ISO 08/CETOP 8
Sandwich Assemblies
ISO 08 / CETOP 8 CIRCUIT SAVER VALVES
(PRESSURE COMPENSATOR / LOAD SENSING / REGENERATIVE)
T-13A Cavity/T-19A Cavity
All sandwich bodies
shown below are 4.50” wide
Y
X
x
p
t
b
a
y
LPJC-XHN
3.44
External
Shuttle Port
Ext.
X
P
T
B
A
0
.25
(4) – 121 O–rings
YFIA-XHN-CA
None
p
t
b
(2) – 114 O–rings
5.94
YFIB-XHN-CA
*Add modifier /S to order Ductile Iron for pressure
rating on YFIB over 3000 psi. Add /S for YFIA.
1.68 1.12
Max.
.23
SAE-4
x
YFIB: Pressure Compensator (Restrictive)
with External Port
CSAB-BXN
Y
Assembly
Model Code*
External
Shuttle Port
Function
Shuttle A and B (Output External)
y
a
1.44
Ext.
X
P
T
B
1/4” NPTF
Port in end
of Cartridge
0
Y
A
Function
YFIA: Pressure Compensator (Restrictive)
3.44
(4) – 121 O–rings
(2) – 114 O–rings
Assembly
Model Code*
5.94
.19
Max.
CSAA-BXN-IBS
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
y
X
P
T
B
A
Y
CBIA-LHN
3.44
Function
B to A Regenerative (High Capacity)
COJA-XEN
0
.25
(4) – 121 O–rings
Assembly
Model Code*
5.94
YDGF-LHN-CA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
x
p
t
b
a
y
X
P
T
B
A
Y
Assembly
Model Code*
YDGE-LHN-CA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.12
2.56
2.31
Max.
L Control
COJA–XEN
3.44
0
CBIA–LHN
(2) – 114 O–rings
.25
(4) – 121 O–rings
2.31
Max. 1.72
L Control
Function
A to B Regenerative (High Capacity)
(2) – 114 O–rings
5.94
1.12 1.12
NOTES: Page 50 for cartridge model CB*A-*** shows performance curves, technical tips, and options.
See page 140 for technical information about sandwich bodies including ISO interface patterns, mounting instructions, studrods, and studkits.
Go to www.sunhydraulics.com for more product information.
202
US Selected Assemblies Catalogue #999-901-192
Standard Assemblies
Assembly Type
Page
CUSHION LOCK VALVES
Dual Load Control Applications
Two Cavity with Checks
Two Cavity with Checks and Shuttle
Two Cavity with Anti-Cavitations Checks
Two Cavity with Anti-Cavitations Checks and Shuttle
205
207
209
211
HYDROSTATIC TRANSMISSION VALVES
AND HOT OIL SHUTTLES
Hot Oil Shuttle and Relief Applications
Inline/1.00” SAE Flange Port
Inline
1.50” SAE Flange Port
2.00” SAE Flange Port
214
215
216
217
Hydrostatic Transmission Applications
Inline
1.00” SAE Flange Port
1.25” SAE Flange Port
1.50”/2.00” SAE Flange Port
218
219
220
221
LINE MOUNTED REGENERATIVE ASSEMBLIES
Pressure Sensitive Applications
15 GPM Maximum Regenerative Flow
10 GPM Maximum Regenerative Flow
30 GPM Maximum Regenerative Flow
20 GPM Maximum Total Flow with Load Holding Check Valve
60 GPM Maximum Regenerative Flow
50 GPM Maximum Regenerative Flow
120 GPM Maximum Regenerative Flow
240 GPM Maximum Regenerative Flow
DIRECT MOTOR MOUNTED ASSEMBLIES
Char-Lynn S Series Motors
Single/Dual Cross-port Relief and Single Counterbalance Applications
Single/Dual Counterbalance and Dual Flow Control Applications
Single Flow Control Applications
Dual Cross-port Relief and Single Counterbalance Applications
Single/Dual Counterbalance Applications
Dual Cross-port Relief and Dual Counterbalance Applications
Danfoss (OMP/OMR Series and OMT Series)
Single/Dual Cross-port Relief and Single Counterbalance Applications
Single/Dual Counterbalance Applications (Shuttles)
Dual Flow Control Applications
Single/Dual Cross-port Relief and Single Counterbalance Applications
Single/Dual Counterbalance Applications (Shuttles)
US Selected Assemblies Catalogue #999-901-192
203
224
224
225
225
226
226
227
227
229
230
231
232
233
234
235
237
238
239
240
241
242
CUSHION LOCK VALVES
Standard Assemblies
TECHNICAL PRODUCT INFORMATION
CUSHION LOCK VALVES
Applications
The cushion lock circuit is used to
control the acceleration, and deceleration
of reciprocating or rotary reversing
circuits. Most slewing type circuits have
inertia loads and it is important that there
is a facility to ensure that during operation
there is good control of the motion. The
cushion lock provides this type of control
using counterbalance valves as both a
relief for acceleration and providing a
braking resistance during deceleration.
Sun offers four basic types of cushion
lock valves:
1.
The basic dual counterbalance valve
assembly with the check valves in
supply lines and separate tank return
line.
3.
The assembly that incorporates the
same features as version 1. but with
additional anti-cavitation check
valves from the external tank line to
the service lines.
C2
C1
T
Tank
V2
V1
4.
The assembly as in version 3. but with
a shuttle valve to release a springapplied mechanical brake.
C2
C1
T
C2
C1
Design Concepts and Features
The use of counterbalance valves
provides smooth control of the motion
because the valves are modulating load
control valves.
The valves are also seated so provide
good load locking capability, although on
most motor applications a mechanical
brake supplements this because there is
always leakage across the motor.
A wide range of pilot ratios and
pressure ratings are available for the
counterbalance valves to enable the most
suitable valves to be selected for the
application.
The check valves used for anticavitation have low cracking pressure of
5 psi to create the least resistance.
The valves are also available in ISO
sandwiches or could be made in custom
manifolds to suit a particular application.
T
Tank
Tank
V1
V2
Brake
Shuttle
2.
S
V1
V2
The basic assembly as above but with
a shuttle valve to release a springapplied mechanical brake.
C2
C1
T
Tank
Brake
Shuttle
S
V1
V2
204
US Selected Assemblies Catalogue #999-901-192
CUSHION LOCK VALVES
Standard Assemblies: Cushion Lock Valves
DUAL LOAD CONTROL APPLICATIONS
(TWO CAVITY WITH CHECKS)
PILOT RATIOS
1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1
C1
T
0-15 GPM
C2
Cavity T-11A
CXCD-XCN
2 places
.72
V1
Ports
C1, C2
V1, V2
3.00
V2
V1
V2
2.31
Assembly
Model Code*
Port T
3/8” NPTF
1/2” NPTF
CBC*-L*N-EMB
1/2” NPTF
1/2” NPTF
CBC*-L*N-EMC
SAE-8
SAE-10
CBC*-L*N-EMJ
SAE-10
SAE-10
CBC*-L*N-EMK
L Control
1.28
Max.
1.12
C1
1.12
C2
T
.38
0
3.00 2.12 1.50 .88
0
0 .38
0
1.50
3.12 3.50
0
.75
2.25
Mounting Holes:
.34 diameter through hole
2 places.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
C1
T
0-30 GPM
C2
Cavity T-2A
CXED-XCN
2 places
.66
3.75
V1
V2
V2
Ports
C1, C2
V1, V2
Port T
Assembly
Model Code*
1/2” NPTF
3/4” NPTF
CBE*-L*N-BMC
3/4” NPTF
3/4” NPTF
CBE*-L*N-BMD
SAE-10
SAE-12
CBE*-L*N-BMK
SAE-12
SAE-12
CBE*-L*N-BML
V1
2.87
L Control
1.57
Max.
1.25
1.25
C2
2.25
.75
.38
0
3.00 2.25 1.50 .75
0
0 .38
1.47
0
3.62 4.00
Mounting Holes:
.42 diameter through hole
2 places.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
US Selected Assemblies Catalogue #999-901-192
C1
T
205
0
CUSHION LOCK VALVES
Standard Assemblies: Cushion Lock Valves
DUAL LOAD CONTROL APPLICATIONS
(TWO CAVITY WITH CHECKS)
PILOT RATIOS
1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1
C1
T
0-60 GPM
C2
Cavity T-17A
CXGD-XCN
2 places
.94
0
5.25
V1
V2
V1
V2
Ports
C1, C2
V1, V2
Port T
Assembly
Model Code*
1” NPTF
1 1/4” NPTF
CBG*-L*N-HME
1 1/4” NPTF
1 1/4” NPTF
CBG*-L*N-HMF
SAE-16
SAE-20
CBG*-L*N-HMM
SAE-20
SAE-20
CBG*-L*N-HMN
3.94
L Control
1.84
Max.
1.88
1.88
C1
C2
1.12
3.88
T
.50
0
0
5.00
3.44 2.50 1.56
0 .50
0
1.81
4.50 5.00
Mounting Holes:
.53 diameter through hole
2 places.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
C1
T
0-120 GPM
C2
0
Cavity T-19A
4.34
1.53
6.00
0
1.72
V1
Ports
C1, C2
V1, V2
Port T
L Control
2.34 Max.
Assembly
Model Code*
1 1/2” SAE C61 1 3/8” NPTF
YCJD-L*N-AR
1 1/2” SAE C61 1 3/8” NPTF
YCJD-L*N-GR
1 1/2” SAE C61 1 3/8” NPTF
YCJD-L*N-HR
0
0
C2
1.84
C1
5.75
3.80
V1
5.88
7.75
1.72
0
1.72
V2
3.80
V2
6.00
0
5.88
T
1.13
Max.
8.25
Model Code
YCJD-L*N-AR
YCJD-L*N-GR
YCJD-L*N-HR
8.25
Pilot Ratio
3:1
4.5:1
10:1
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
206
US Selected Assemblies Catalogue #999-901-192
CUSHION LOCK VALVES
Standard Assemblies: Cushion Lock Valves
DUAL LOAD CONTROL APPLICATIONS
(TWO CAVITY WITH CHECKS AND SHUTTLE)
PILOT RATIOS
1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1
0-15 GPM
Cavity T-11A
C1 T C2
CXCD-XCN
2 places
.72
V1 S
V2
3.00
V1
V2
Ports
C1, C2
V1, V2
Port T
Port S
3/8” NPTF
1/2” NPTF
1/4” NPTF
CBC*-L*N-ENB
1/2” NPTF
1/2” NPTF
1/4” NPTF
CBC*-L*N-ENC
SAE-8
SAE-10
SAE-4
CBC*-L*N-ENJ
SAE-10
SAE-10
SAE-4
CBC*-L*N-ENK
2.31
Assembly
Model Code*
L Control
1.28
Max.
1.12
C2
C1
1.12
T
.38
0
3.00 2.12 1.50 .88
0
0 .38
0
1.50
3.12 3.50
0
2.25
.75
Mounting Holes:
.34 diameter through hole
2 places.
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
0-30 GPM
Cavity T-2A
C1 T C2
CXED-XCN
2 places
.66
3.75
V1 S
V2
V1
V2
Ports
C1, C2
V1, V2
Port T
Port S
1/2” NPTF
3/4” NPTF
1/4” NPTF
CBE*-L*N-BNC
3/4” NPTF
3/4” NPTF
1/4” NPTF
CBE*-L*N-BND
SAE-10
SAE-12
SAE-4
CBE*-L*N-BNK
SAE-12
SAE-12
SAE-4
CBE*-L*N-BNL
2.88
Assembly
Model Code*
1.25
1.25
C1
C2
.75
1.50 2.25 3.00
T
.38
0
3.00 2.25 1.50 .75
0
0
0 .38
1.47
3.62 4.00
Mounting Holes:
.42 diameter through hole
2 places.
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
US Selected Assemblies Catalogue #999-901-192
S
2.88
L Control
1.60
Max.
207
0
CUSHION LOCK VALVES
Standard Assemblies: Cushion Lock Valves
DUAL LOAD CONTROL APPLICATIONS
(TWO CAVITY WITH CHECKS WITH SHUTTLE)
PILOT RATIOS
1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1
0-60 GPM
Cavity T-17A
C1 T C2
CXGD-XCN
2 places
.94
5.25
V1 S
V2
V1
V2
Ports
C1, C2
V1, V2
Port T
Port S
Assembly
Model Code*
1” NPTF
1 1/4” NPTF
1/4” NPTF
CBC*-L*N-HNE
1 1/4” NPTF
1 1/4” NPTF
1/4” NPTF
CBC*-L*N-HNF
SAE-16
SAE-20
SAE-4
CBC*-L*N-HNM
SAE-20
SAE-20
SAE-4
CBC*-L*N-HNN
3.94
S
3.94
L Control
1.84
Max.
1.88
C1
1.88
C2
T
.50
0
5.00
3.44 2.50 1.56
0
0
0 .50
1.81
0
4.50
1.12
2.50
3.88
1.72
0
Mounting Holes:
.53 diameter through hole
2 places.
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
0-120 GPM
Cavity T-19A
C1 T C2
0
1.53
4.34
6.00
0
Ports
C1, C2
V1, V2
Port T
0
0
1.72
C2
1.84
C1
5.75
S
V2
Port S
0
V2
1.72
V1 S
6.00
L Control
2.34 Max.
3.80
3.80
Assembly
Model Code*
1 1/2” SAE C61 1 3/8” NPTF
1/4” NPTF
YCJH-L*N-AR
1 1/2” SAE C61 1 3/8” NPTF
1/4” NPTF
YCJH-L*N-GR
1 1/2” SAE C61 1 3/8” NPTF
SAE-4
YCJH-L*N-HR
V1
5.88
7.75
T
5.88
1.13
Max.
8.25
Model Code
YCJH-L*N-AR
YCJH-L*N-GR
YCJH-L*N-HR
8.25
Pilot Ratio
3:1
4.5:1
10:1
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
208
US Selected Assemblies Catalogue #999-901-192
CUSHION LOCK VALVES
Standard Assemblies: Cushion Lock Valves
DUAL LOAD CONTROL APPLICATIONS
(TWO CAVITY WITH ANTI-CAVITATION CHECKS)
PILOT RATIOS
1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1
C1
T
0-15 GPM
C2
Cavity T-11A
CXCD-XAN
2 places
CXDA-XAN
2 places
.72
V1
3.00
V2
V1
V2
Ports
C1, C2
V1, V2
Port T
Assembly
Model Code*
3/8” NPTF
1/2” NPTF
CBC*-L*N-EPB
1/2” NPTF
1/2” NPTF
CBC*-L*N-EPC
SAE-8
SAE-10
CBC*-L*N-EPJ
SAE-10
SAE-10
CBC*-L*N-EPK
L Control
1.28
Max.
2.31
1.12
1.12
C1
C2
.75
2.25
T
.38
0
3.00
2.12 1.50 .88
0
0 .38
1.50
0
3.12 3.50 0
Mounting Holes:
.34 diameter through hole
2 places.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
C1
T
0-30 GPM
C2
Cavity T-2A
CXFA-XAN
2 places
CXED-XAN
2 places
.66
3.75
V1
Ports
C1, C2
V1, V2
V2
V2
Port T
Assembly
Model Code*
1/2” NPTF
1/2” NPTF
CBE*-L*N-BPC
3/4” NPTF
3/4” NPTF
CBE*-L*N-BPD
SAE-10
SAE-12
CBE*-L*N-BPK
SAE-12
SAE-12
CBE*-L*N-BPL
V1
2.87
L Control
1.57
Max.
1.25
1.25
C2
2.25
.75
.38
0
3.00 2.25 1.50
.75
0
0
1.47
3.63 4.00
Mounting Holes:
.42 diameter through hole
2 places.
0 .38
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
US Selected Assemblies Catalogue #999-901-192
C1
T
209
0
0
CUSHION LOCK VALVES
Standard Assemblies: Cushion Lock Valves
DUAL LOAD CONTROL APPLICATIONS
(TWO CAVITY WITH ANTI-CAVITATION CHECKS)
PILOT RATIOS
1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1
C1
T
0-60 GPM
C2
Cavity T-17A
CXGD-XAN
2 places
CXHA-XAN
2 places
.94
3.00
V1
V2
V1
V2
Ports
C1, C2
V1, V2
Port T
Assembly
Model Code*
1” NPTF
1 1/4” NPTF
CBG*-L*N-HPE
1 1/4” NPTF
1 1/4” NPTF
CBG*-L*N-HPF
SAE-16
SAE-20
CBG*-L*N-HPM
SAE-20
SAE-20
CBG*-L*N-HPN
3.94 L Control
1.84
Max.
1.88
1.88
C1
C2
1.12
3.88
T
.50
0
5.00
0
3.44 2.50 1.56
0 .50
1.81
0
4.50 5.00
0
Mounting Holes:
.53 diameter through hole
2 places.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
C1
T
0-120 GPM
C2
0
1.53
Cavity T-19A
4.34
6.00
Ports
C1, C2
V1, V2
Port T
V2
0
V2
1.72
V1
6.00
L Control
2.34 Max.
0
1.72
1 1/2” SAE C61 1 3/8” NPTF
YCJE-L*N-AR
1 1/2” SAE C61 1 3/8” NPTF
YCJE-L*N-GR
1 1/2” SAE C61 1 3/8” NPTF
YCJE-L*N-HR
V1
5.88
7.75
0
0
C2
1.84
C1
5.75
3.80
3.80
Assembly
Model Code*
1.72
0
5.88
1.13
Max.
T
8.25
Model Code
YCJE-L*N-AR
YCJE-L*N-GR
YCJE-L*N-HR
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
8.25
Pilot Ratio
3:1
4.5:1
10:1
NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
210
US Selected Assemblies Catalogue #999-901-192
CUSHION LOCK VALVES
Standard Assemblies: Cushion Lock Valves
DUAL LOAD CONTROL APPLICATIONS
(TWO CAVITY WITH ANTI-CAVITATION CHECKS AND SHUTTLE)
PILOT RATIOS
1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1
0-15 GPM
C1 T C2
Cavity T-11A
CXDA-XAN
2 places
CXCD-XAN
2 places
.72
3.00
V1 S V2
V2
Ports
C1, C2
V1, V2
Port T
Port S
Assembly
Model Code*
3/8” NPTF
1/2” NPTF
1/4” NPTF
CBC*-L*N-EQB
1/2” NPTF
1/2” NPTF
1/4” NPTF
CBC*-L*N-EQC
SAE-8
SAE-10
SAE-4
CBC*-L*N-EQJ
SAE-10
SAE-10
SAE-4
CBC*-L*N-EQK
2.31 L Control
1.28
Max.
V1
S
2.31
1.12
1.12
C1
C2
T
.38
0
3.00
2.12 1.50 .88
0
0 .38
1.50
0
3.12 3.50 0
.75
1.50
2.25
Mounting Holes:
.34 diameter through hole
2 places.
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
0-30 GPM
C1 T C2
Cavity T-2A
CXFA-XAN
2 places
CXED-XAN
2 places
.66
3.75
V1 S V2
Ports
C1, C2
V1, V2
Port T
Port S
2.88
Assembly
Model Code*
1/2” NPTF
3/4” NPTF
1/4” NPTF
CBE*-L*N-BQC
3/4” NPTF
3/4” NPTF
1/4” NPTF
CBE*-L*N-BQD
SAE-10
SAE-12
SAE-4
CBE*-L*N-BQK
SAE-12
SAE-12
SAE-4
CBE*-L*N-BQL
2.88
L Control
1.60
Max.
1.25
1.25
0
3.00 2.25 1.50 .75
0
0 .38
1.47
.38
0
3.62 4.00
0
Mounting Holes:
.42 diameter through hole
2 places.
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult the Sun Factory for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
US Selected Assemblies Catalogue #999-901-192
211
S
C1
C2
.75 1.50 2.25 3.00
CUSHION LOCK VALVES
Standard Assemblies: Cushion Lock Valves
DUAL LOAD CONTROL APPLICATIONS
(TWO CAVITY WITH ANTI-CAVITATION CHECKS AND SHUTTLE)
PILOT RATIOS
1.5:1, 2:1, 2.3:1, 3:1, 4.5:1, 10:1
0-60 GPM
C1 T C2
Cavity T-17A
CXGD-XAN
2 places
CXHA-XAN
2 places
0
.94
3.00
V1 S V2
V1
V2
Ports
C1, C2
V1, V2
Port T
Port S
Assembly
Model Code*
1” NPTF
1 1/4” NPTF
1/4” NPTF
CBG*-L*N-HQE
1 1/4” NPTF
1 1/4” NPTF
1/4” NPTF
CBG*-L*N-HQF
SAE-16
SAE-20
SAE-4
CBG*-L*N-HQM
SAE-20
SAE-20
SAE-4
CBG*-L*N-HQN
3.94
1.88
1.88
S
C1
C2
.50
T
5.00
3.94 L Control
1.84
Max.
0
0
3.44 2.50 1.56
0
0 .50
1.81
4.50 5.00
0
1.12
2.50
3.88
Mounting Holes:
.53 diameter through hole
2 places.
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
0-120 GPM
C1 T C2
0
1.53
Cavity T-19A
4.34 6.00
L Control
2.34 Max.
0
Ports
C1, C2
V1, V2
3.80
3.80
Port S
Assembly
Model Code*
1 1/2” SAE C61 1 3/8” NPTF
1/4” NPTF
YCJG-L*N-AR
1 1/2” SAE C61 1 3/8” NPTF
1/4” NPTF
YCJG-L*N-GR
1 1/2” SAE C61 1 3/8” NPTF
SAE-4
YCJG-L*N-HR
Port T
V1
5.88
7.75
1.72
5.88
0
0
0
1.72
V2
1.72
V1 S V2
6.00
0
C2
1.84
C1
5.75
S
1.13
Max.
T
8.25
Model Code
YCJG-L*N-AR
YCJG-L*N-GR
YCJG-L*N-HR
8.25
Pilot Ratio
3:1
4.5:1
10:1
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
NOTES: Page 50 for cartridge model CB**-*** and page 102 for CX*D-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
212
US Selected Assemblies Catalogue #999-901-192
Standard Assemblies
TECHNICAL PRODUCT INFORMATION
HYDROSTATIC TRANSMISSION VALVES AND HOT OIL SHUTTLES
Applications
In all closed loop hydrostatic
transmission circuits it is necessary to
remove and replace some of the oil
from the circuit to provide cooling and
filtration. The normal rule of thumb is
to continuously take out 10-15% of
the pump flow. This is achieved using
a hot oil shuttle valve with lowpressure relief.
G3
G1
1
1
2
2
T
G2
The hot oil shuttle valve senses
pressure from the high-pressure side
and opens to bleed off oil from the
return low-pressure side of the circuit.
A low-pressure charge pump into the
inlet of the transmission pump makes
up this oil.
US Selected Assemblies Catalogue #999-901-192
2
1
G
T
2
1
The oil passed through the hot oil
shuttle valve goes across a lowpressure relief valve set at a slightly
lower pressure than the charge pump.
This oil is taken through an offline
filtration and cooling unit before
being returned to the oil reservoir.
Often this oil is also passed through
the casing drain of the transmission
motor to help keep the motor cool.
The other main requirement for
close loop circuits is cross line relief
valves to provide protection from over
pressurization to the pump and motor.
213
Design Concepts and Features
Sun offers a complete range of hot
oil shuttle valves and hydrostatic
transmission valves incorporating four
through ports for easy installation into
the circuit. The use of cartridge valves
in these packages means an
elimination of pipe work and provides
easy maintenance. In the event of a
problem, it simply means replacing a
cartridge rather than the complete
valve assembly. This reduces cost and
eliminates down time. The cross line
relief valves used are fast acting with
limited overshoot to provide excellent
protection from over pressurization.
Sun can provide packages to handle
transmission flows from 10 GPM right
up to 240 GPM and pressures up to
5000 psi. As well as the standard
packages shown in the catalogue, Sun
can also design a custom package to
suit the exact requirement for a
customer’s application.
HOT OIL SHUTTLE AND RELIEF APPLICATIONS
(INLINE / 1.00” SAE FLANGE PORT BODIES)
PILOT OPERATED
2
1
0-13 GPM
G
T
Cavity T-10A
DSCH-XHN
Mounting Holes:
(opposite side)
.375-16 UNC-2B x.62 deep
1.08
SAE-6 Gauge Port
4.00
3.62
2
1
1
Ports
1 and 2
Port T
Assembly
Model Code*
SAE-10
SAE-12
SAE-8
SAE-8
XRDC-LNN-AK
XRDC-LNN-AL
1
RPEC-LNN
2.75
G
T
2.16
1.84
2
2
.91
.38
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0
2.44 2.12
3.50
2
1
0
0
1.11
2.75
P = psi
400
300
200
100
0
3
6
9
12
15
Flow = GPM
0-25 GPM
G
1.12
Typical Hot Oil
Relief/Shuttle Performance
These Sun valve assemblies are for use in
bleeding hot oil from the low pressure side of
a hydrostatic transmission circuit. The hot oil
can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases.
The hot oil is removed from the loop when
the Sun RPEC cartridge is set below the
hydrostatic charge pressure relief valve.
Cavity T-10A
DSEH-XHN
T
Mounting Holes:
(opposite side)
.375-16 UNC-2B x .62 deep.
2 places.
SAE-6 Gauge Port
1.25
4.19
3.84
2
1
1
1
3.00
RPEC-LNN
Ports
1 and 2
Port T
Assembly
Model Code*
SAE-12
SAE-10
XRFC-LNN-AL
T
1.94
1.97
1.91
G
2
2
.94
.34
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0
4.00
2.66 2.25
These Sun valve assemblies are for use in
bleeding hot oil from the low pressure side of
a hydrostatic transmission circuit. The hot oil
can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases.
The hot oil is removed from the loop when
the Sun RPEC cartridge is set below the
hydrostatic charge pressure relief valve.
1.38
0
0
1.09
3.00
Typical Hot Oil
Relief/Shuttle Performance
500
P = psi
HOT OIL SHUTTLE
Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles
400
300
200
100
0
7.5
15
22.5
30
Flow = GPM
NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
214
US Selected Assemblies Catalogue #999-901-192
HOT OIL SHUTTLE
Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles
HOT OIL SHUTTLE AND RELIEF APPLICATIONS
(INLINE BODIES)
PILOT OPERATED
2
1
0-50 GPM
G
T
Cavity T-3A
DSGH-XHN
Mounting Holes:
(opposite side)
.375-16 UNC-2B x.62 deep
1.56
SAE-6 Gauge Port
5.25
4.75
2
2
1
Ports
1 and 2
Port T
Assembly
Model Code*
SAE-16
SAE-12
XRHC-LNN-AM
RPGC-LNN
2
T
2.06
3.88
G
1
2.69
1
1.52
.50
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0
These Sun valve assemblies are for use in
bleeding hot oil from the low pressure side of
a hydrostatic transmission circuit. The hot oil
can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases.
The hot oil is removed from the loop when
the Sun RPGC cartridge is set below the
hydrostatic charge pressure relief valve.
2
1
0-100 GPM
G
T
3.31 3.00
1.81
0
0
1.38
3.50
Typical Hot Oil
Relief/Shuttle Performance
500
400
P = psi
4.50
300
200
100
15
0
30
45
60
Flow = GPM
Cavity T-16A
DSIH-XHN
Mounting Holes:
(opposite side)
.375-16 UNC-2B x.62 deep
SAE-6 Gauge Port
1.94
6.25
5.75
2
2
1
T
RPIC-LNN
Ports
1 and 2
Port T
Assembly
Model Code*
SAE-20
SAE-16
XRJC-LNN-AM
2
2.38
4.72
G
1
3.17
1
1.69
.50
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0
6.00
0
2.44
0
Typical Hot Oil
Relief/Shuttle Performance
500
P = psi
These Sun valve assemblies are for use in
bleeding hot oil from the low pressure side of
a hydrostatic transmission circuit. The hot oil
can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases.
The hot oil is removed from the loop when
the Sun RPIC cartridge is set below the
hydrostatic charge pressure relief valve.
4.56 4.00
400
300
200
100
0
30
60
90
Flow = GPM
NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
US Selected Assemblies Catalogue #999-901-192
215
120
1.50
4.50
HOT OIL SHUTTLE AND RELIEF APPLICATIONS
(1.50” SAE FLANGE PORT BODIES)
PILOT OPERATED
2
1
0-100 GPM
G
Cavity T-16A
DSIH-XHN
T
1.62
SAE-6 Gauge Port
6.62
6.12
RPIC-LNN
2
2
2
Ports
1 and 2
Port T
Assembly
Model Code*
1 1/2”SAE C61
SAE-16
XRJC-LNN-AR
T
G
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
1
.50
0
4.56
2.38
0
.47
0
6.00
2.25
Typical Hot Oil
Relief/Shuttle Performance
These Sun valve assemblies are for use in
bleeding hot oil from the low pressure side of
a hydrostatic transmission circuit. The hot oil
can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases.
The hot oil is removed from the loop when
the Sun RPIC cartridge is set below the
hydrostatic charge pressure relief valve.
500
P = psi
400
300
200
100
60
30
0
0-100 GPM
G
1.66
Mounting Holes:
(opposite side)
.375-16 UNC-2B
x.62 deep
5.94
1
1.50” SAE Code 61
4-Bolt Flange Pattern
4 places.
3.31
1
2
4.97
2.38
1
90
Flow = GPM
120
Cavity T-16A
DSIH-XHN
T
SAE-6 Gauge Port
1.12
7.75
7.25
2
RPIC-LNN
2.38
1
Ports
1 and 2
Port T
Assembly
Model Code*
1 1/2” SAE C62
SAE-16
XRJC-LNN-A6
2
2
T
G
1.50” SAE Code 62
4-Bolt Flange Pattern
4 places.
3.88
1
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
5.84
1
1.91
Mounting Holes:
(opposite side)
.375-16 UNC-2B
x.62 deep
.50
0
6.94
5.56
3.38
.47 0
0
2.25
6.00
Typical Hot Oil
Relief/Shuttle Performance
These Sun valve assemblies are for use in
bleeding hot oil from the low pressure side of
a hydrostatic transmission circuit. The hot oil
can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases.
The hot oil is removed from the loop when
the Sun RPIC cartridge is set below the
hydrostatic charge pressure relief valve.
500
P = psi
HOT OIL SHUTTLE
Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles
400
300
200
100
0
30
60
90
Flow = GPM
120
NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
216
US Selected Assemblies Catalogue #999-901-192
HOT OIL SHUTTLE
Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles
HOT OIL SHUTTLE AND RELIEF APPLICATIONS
(2.00” SAE FLANGE PORT BODY)
PILOT OPERATED
G3
0-100 GPM
G1
1
Cavity T-16A
1
DSIH-XHN
SAE-6 Gauge Ports
1.06
7.75
2
7.25
2
T
G2
Ports
1 and 2
Port T
Assembly
Model Code*
2” SAE C61
SAE-16
XRJC-LNN-AS
RPIC-LNN
2.38
2
2
G
T
Mounting Holes:
(opposite side)
.375-16 UNC-2B
x.62 deep
5.81
2.00” SAE Code 61
4-Bolt Flange Pattern
4 places.
3.88
1
1
1.94
.50
0
These Sun valve assemblies are for use in
bleeding hot oil from the low pressure side of
a hydrostatic transmission circuit. The hot oil
can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases.
The hot oil is removed from the loop when
the Sun RPIC cartridge is set below the
hydrostatic charge pressure relief valve.
4.56
2.38
.47
0
0
2.03
Typical Hot Oil
Relief/Shuttle Performance
500
P = psi
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
5.94
400
300
200
100
0
30
60
90
Flow = GPM
NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
US Selected Assemblies Catalogue #999-901-192
217
120
6.00
HYDROSTATIC TRANSMISSION APPLICATIONS
(INLINE BODY)
DIRECT ACTING
G3
0-25 GPM
G1
1
1
Cavity T-10A
DSCH-XHN
Mounting Holes: (opposite side)
.375-16 UNC-2B x.62 deep
.72
4.50
4.00
2
2
T
1
3.16
G2
Ports
1 and 2
Port T
Ports G1,
G2 & G3
Assembly
Model Code*
SAE-12
SAE-8
1/2” NPTF
XRDB-LCN-AL
2
G2
G1
RDDA-LCN
2.25
Port 2
pressure control
Both ends
2.34
G3
RDDA-LCN
Port 1
pressure control
T
.94
1
.50
2
0
3.62
1.81
0
.84
0
3.16
4.00
1.94
RPEC-LNN
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
These Sun valve assemblies are for use with hydrostatic
transmissions to provide overload relief valve protection for
the main circuit in both directions. Additionally, an auxiliary
shuttle valve allows bleeding of hot oil from the low pressure
side. Hot oil can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases. Hot oil is
removed from the loop when the Sun RPEC cartridge is set
below the hydrostatic charge pressure relief valve.
NOTE: A mechanical brake is recommended to
positively lock any static live load.
Typical Hot Oil
Relief/Shuttle Performance
400
P = psi
HYDROSTATIC
TRANSMISSION VALVES
Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles
300
200
100
0
3
6
9
12
Flow = GPM
15
NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
218
US Selected Assemblies Catalogue #999-901-192
HYDROSTATIC
TRANSMISSION VALVES
Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles
HYDROSTATIC TRANSMISSION APPLICATIONS
(1.00” SAE FLANGE PORT BODIES)
DIRECT ACTING
G3
0-50 GPM
G1
1
1
Cavity T-3A
RDFA-LCN
Port 1
pressure control
3.59
2.38
DSEH-XHN
.50 0
.91
4.78
4.39
G2
2
2
T
RPEC-LNN
2
2
G3
T
Ports
1 and 2
1” SAE C61
3.59
1.94
G2
Port T
Ports G1,
G2 & G3
Assembly
Model Code*
SAE-10
SAE-6
XRFB-LCN-AP
Mounting Holes:
(opposite side)
.375-16 UNC-2B
x.75 deep
1
2.39
1
1.19
.39
0
G1
.47 0
RDFA-LCN
Port 2
pressure control
4.44
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
These Sun valve assemblies are for use with hydrostatic
transmissions to provide overload relief valve protection for
the main circuit in both directions. Additionally, an auxiliary
shuttle valve allows bleeding of hot oil from the low pressure
side. Hot oil can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases. Hot oil is
removed from the loop when the Sun RPEC cartridge is set
below the hydrostatic charge pressure relief valve.
NOTE: A mechanical brake is recommended to
positively lock any static live load.
G3
1
1
1.66
3.44 4.00
P = psi
400
300
200
100
7.5
0
15
22.5
30
Flow = GPM
Cavity T-3A
RDFA-LCN
Port 1
pressure control
2.38
DSEH-XHN
.50
.91
5.88
5.44
G2
2
0
Typical Hot Oil
Relief/Shuttle Performance
500
0-50 GPM
G1
1.00” SAE Code 61
4-Bolt Flange Pattern
4 places.
2
T
RPEC-LNN
1.97
G2
2
2
T
Ports
1 and 2
Port T
Ports G1,
G2 & G3
Assembly
Model Code*
1” SAE C62
SAE-10
SAE-6
XRFB-LCN-A4
2.94
1
Mounting Holes:
(opposite side)
.438-14 UNC-2B
x1.06 deep
1
4.94 4.09
1.00” SAE Code 62
4-Bolt Flange Pattern
4 places.
1.45
.44
0
G1
.47 0
RDFA-LCN
Port 2
pressure control
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
400
300
200
100
0
7.5
15
219
22.5
Flow = GPM
NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
US Selected Assemblies Catalogue #999-901-192
1.66 3.44 4.00
0
Typical Hot Oil
Relief/Shuttle Performance
500
P = psi
These Sun valve assemblies are for use with hydrostatic
transmissions to provide overload relief valve protection for
the main circuit in both directions. Additionally, an auxiliary
shuttle valve allows bleeding of hot oil from the low pressure
side. Hot oil can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases. Hot oil is
removed from the loop when the Sun RPEC cartridge is set
below the hydrostatic charge pressure relief valve.
NOTE: A mechanical brake is recommended to
positively lock any static live load.
4.42
G3
30
HYDROSTATIC TRANSMISSION APPLICATIONS
(1.25” SAE FLANGE PORT BODIES)
DIRECT ACTING
G3
0-100 GPM
G1
1
Cavity T-16A
RDHA-LCN
Port 1
pressure control
1
DSGH-XHN
3.00
.44 0
.94
2
2
T
G2
T
Port T
Ports G1,
G2 & G3
Assembly
Model Code*
SAE-12
SAE-6
XRHB-LCN-AQ
Mounting Holes:
(opposite side)
.375-16 UNC-2B
x.75 deep
6.38
5.81
G2
RPGC-LNN
2
2.09
1
2
4.81
G3
3.19
1
1.56
G1
1.25” SAE Code 61
4-Bolt Flange Pattern
4 places.
.56
0
4.94 3.94
.47 0
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
1
P = psi
500
400
300
200
100
15
0
0-100 GPM
G1
T
Port T
Assembly
Model Code*
DSGH-XHN
3.00
SAE-12
SAE-6
XRHB-LCN-A5
6.38
5.81
G2
T
Mounting Holes:
(opposite side)
.375-16 UNC-2B
x.75 deep
60
.44 0
RPGC-LNN
2
2.09
G2
Ports G1,
G2 & G3
45
Cavity T-16A
.94
2
30
Flow = GPM
RDHA-LCN
Port 1
pressure control
1
2
5.00
4.38
Typical Hot Oil
Relief/Shuttle Performance
These Sun valve assemblies are for use with hydrostatic
transmissions to provide overload relief valve protection for
the main circuit in both directions. Additionally, an auxiliary
shuttle valve allows bleeding of hot oil from the low pressure
side. Hot oil can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases. Hot oil is
removed from the loop when the Sun RPGC cartridge is set
below the hydrostatic charge pressure relief valve.
NOTE: A mechanical brake is recommended to
positively lock any static live load.
G3
0
RDHA-LCN
Port 2
pressure control
1
G1
2
4.81
G3
3.19
1
1.56
1.25” SAE Code 62
4-Bolt Flange Pattern
4 places.
.56
0
4.94 3.94
.47 0
0
4.38 5.00
RDHA-LCN
Port 2
pressure control
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
These Sun valve assemblies are for use with hydrostatic
transmissions to provide overload relief valve protection for
the main circuit in both directions. Additionally, an auxiliary
shuttle valve allows bleeding of hot oil from the low pressure
side. Hot oil can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases. Hot oil is
removed from the loop when the Sun RPGC cartridge is set
below the hydrostatic charge pressure relief valve.
NOTE: A mechanical brake is recommended to
positively lock any static live load.
Typical Hot Oil
Relief/Shuttle Performance
500
P = psi
HYDROSTATIC
TRANSMISSION VALVES
Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles
400
300
200
100
0
15
30
45
Flow = GPM
60
NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
220
US Selected Assemblies Catalogue #999-901-192
HYDROSTATIC
TRANSMISSION VALVES
Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles
HYDROSTATIC TRANSMISSION APPLICATIONS
(1.50” / 2.00” SAE FLANGE PORT BODIES)
DIRECT ACTING
G3
0-200 GPM
G1
1
Cavity T-18A
RDJA-LCN
Port 1
pressure control
1
3.88
2.00
DSIH-XHN
.69
7.75
2
2
T
RPIC-LNN
2.41
G2
7.25
G2
2
T
Ports
1 and 2
Port T
Ports G1,
G2 & G3
Assembly
Model Code*
1 1/2” SAE C61
SAE-16
SAE-6
XRJB-LCN-AR
Ports
1 and 2
2” SAE C61
SAE-6
XRJB-LCN-AS
P = psi
200
100
0
30
120
Cavity T-18A
RPIC-LNN
2.41
Mounting Holes:
(opposite side)
.375-16 UNC-2B
x.88 deep
90
60
Flow = GPM
3.88
DSIH-XHN
.69 0
8.19
7.72
G2
2
1
G1
2
6.19
G3
4.09
1
2.00
2.00” SAE Code 61
4-Bolt Flange Pattern
4 places.
.47
0
6.94 5.69
.47 0
0
6.00
5.25
RDJA-LCN
Port 2
pressure control
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
Typical Hot Oil
Relief/Shuttle Performance
500
400
P = psi
These Sun valve assemblies are for use with hydrostatic
transmissions to provide overload relief valve protection for
the main circuit in both directions. Additionally, an auxiliary
shuttle valve allows bleeding of hot oil from the low pressure
side. Hot oil can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases. Hot oil is
removed from the loop when the Sun RPIC cartridge is set
below the hydrostatic charge pressure relief valve.
NOTE: A mechanical brake is recommended to
positively lock any static live load.
300
200
100
0
30
60
221
90
Flow = GPM
NOTES: Page 2 for cartridge model RP*C-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
US Selected Assemblies Catalogue #999-901-192
6.00
300
T
Port T
2.25
400
G2
SAE-16
0
Typical Hot Oil
Relief/Shuttle Performance
RDJA-LCN
Port 1
pressure control
2
Assembly
Model Code*
.50
500
0-200 GPM
Ports G1,
G2 & G3
1.88
.47 0
.78
T
1
1.50” SAE Code 61
4-Bolt Flange Pattern
4 places.
RDJA-LCN
Port 2
pressure control
1
2
3.88
0
These Sun valve assemblies are for use with hydrostatic
transmissions to provide overload relief valve protection for
the main circuit in both directions. Additionally, an auxiliary
shuttle valve allows bleeding of hot oil from the low pressure
side. Hot oil can be cooled, filtered, or used as a source of
oil for flushing other pump and motor cases. Hot oil is
removed from the loop when the Sun RPIC cartridge is set
below the hydrostatic charge pressure relief valve.
NOTE: A mechanical brake is recommended to
positively lock any static live load.
1
G3
G1
*Add modifier /S to order Ductile Iron for pressure rating over 3000
psi.
G1
5.88
1
Mounting Holes:
(opposite side)
.375-16 UNC-2B
x.88 deep
6.94 5.56
G3
2
120
Standard Assemblies: Hydrostatic Transmission Valves and Hot Oil Shuttles
NOTES
222
US Selected Assemblies Catalogue #999-901-192
Standard Assemblies
TECHNICAL PRODUCT INFORMATION
LINE MOUNTED REGENERATIVE ASSEMBLIES
It is important to remember to size pipe
work correctly to allow for the increased
flow going into the full bore side of the
cylinder.
US Selected Assemblies Catalogue #999-901-192
Full
Bore
Normal Operation
Cylinder
Annulus
Oil from the pump fills the full bore of
a cylinder. With a cylinder ratio of 2:1 and
the annulus connected to tank the flow out
of the annulus is half of the flow into the
full bore.
Regenerative Operation
Full
Bore
The pressure sensitive regenerative
circuit is used in many applications such
as compacting machines. The first part of
the cylinder extension occurs when there
is very little load (for example during
initial compaction) and regeneration
provides a faster speed. When the load
resistance increases, the pressure on the
full bore side starts to increase and will
pilot open a counterbalance valve
connecting the rod side to tank and take
the circuit out of regeneration. This then
provides a slower speed, as it is now
operating on the full bore area, but also a
corresponding increase in force.
Regenerative circuits do not affect the
retraction of the cylinder.
The illustration shows the appropriate
calculations for regenerative circuits.
Rod
Sun offers two types of regenerative
valve assemblies. One provides full time
regeneration and the other is a pressure
sensitive regenerative circuit. The full
time regeneration has only a limited
number of applications and is most
commonly used for providing fast
extension speeds with low force.
The circuit Sun uses for all types of
regeneration includes a pilot to close
check valve connecting from the rod side
to the full bore side. If this circuit is used
in applications where the load can extend
the cylinder it will be necessary to
incorporate a vented load control valve on
the rod side to prevent the load running
away.
Rod
Applications
Regenerative circuits are used to
provide faster cylinder extension speeds
by taking the oil from the rod end and
diverting it to the head end of the cylinder.
This means that the effective area during
extension is only the rod area that gives a
faster speed but also a reduced force.
This means using a cylinder with a 2:1
area ratio between piston and rod, equal
speeds and forces can be obtained in both
directions without using a double rod.
Rod
Annulus Oil
Pump Flow
During regen, pump flow into the full
bore end fills only the effective area of the
rod. The area not filled by the pump flow
is made up by the annulus oil feeding back
into the full bore. Hence, the reason why
during regen, the cylinder extends at a
faster rate.
223
Design Concepts and Features
The first main feature of all Sun
regenerative packages is that they are
installed after the directional valve
controlling the actuator. This means that
the higher flows generated are not passed
through the directional valve, which can
be the same size as for normal circuits.
This also means that this package can
more easily be added to an existing circuit
with the minimum of disruption.
The main feature for the pressure
sensitive regenerative circuit is that Sun
uses a counterbalance valve to transfer
from regeneration to normal operation.
This type of valve opens gradually as the
pilot pressure increases and gives a much
smoother transition compared to the more
commonly used sequence valve. It
therefore eliminates a great deal of the
shock, which can occur during this
transition.
The assemblies can be supplied for
various flow rates and packages such as
line mounted, ISO sandwich assemblies
and gasket-mounted subplates. It is also
possible to mount the cartridges directly
into the cylinder head.
PRESSURE SENSITIVE REGENERATION APPLICATIONS
REGENERATION
15 GPM Maximum Regenerative Flow
CR
CBCA-LHN
CR
1.28
CODA-XEN
.50
3.00
VR
Ports CH,
CR & VR
Assembly
Model Code*
1/2” NPTF
SAE-10
YDCC-LHN-AC
YDCC-LHN-AK
Mounting Holes:
.34 diameter through hole
2 places.
CH
VR
1.56
.50
CR
0
3.62
3.31
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.81
.31 0
0
.62
1.25
Pressure Drop
300
P = psi
Regeneration diminishes progressively above
setting of CBCA.
NOTE: Refer to page 223 if load causes
cylinder to extend.
*For part number and price for body only
contact your local Sun distributor.
200
CR to CH
100
VR to CR
3.75
0
7.5
11.25
15
Flow = GPM
10 GPM Maximum Regenerative Flow
CR
CH
CKEB-LCN
CBCA-LHN
2.09
VR
Ports CH,
CR & VR
1/2” NPTF
SAE-10
CODA-XEN
.50
CBCA-LHN
1.28
VH
Assembly
Model Code*
YDCD-LHN-AC
YDCD-LHN-AK
Mounting Holes:
.34 diameter through hole
2 places.
VH
VR
CH
CR
3.74
1.81
1.56
.50
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
5.12
4.81
.31 0
0
.75
1.50
Pressure Drop
Includes CKEB load holding check valve.
Regeneration diminishes progressively above
setting of CBCA.
NOTE: Refer to page 223 if load causes
cylinder to extend.
*For part number and price for body only
contact your local Sun distributor.
300
P = psi
REGENERATIVE
Standard Assemblies: Line Mounted Regenerative Assemblies
200
CR to CH
VR to CR
100
VH to CH
0
2.5
5
7.5
10
Flow = GPM
NOTES: Page 50 for cartridge model CB**-*** and page 78 for CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
224
US Selected Assemblies Catalogue #999-901-192
REGENERATIVE
Standard Assemblies: Line Mounted Regenerative Assemblies
PRESSURE SENSITIVE REGENERATION APPLICATIONS
REGENERATION
30 GPM Maximum Regenerative Flow
CR
CBEA-LHN
CH
COFA-XEN
1.59
.59
3.25
CR
Ports CH,
CR & VR
Assembly
Model Code*
3/4” NPTF
SAE-12
YDEC-LHN-AD
YDEC-LHN-AL
Mounting Holes:
.42 diameter through hole
2 places.
VR
CH
1.75
CR
.50
0
4.50 4.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2.25
.50
0
0
.75
1.50
Pressure Drop
300
P = psi
Regeneration diminishes progressively above
setting of CBEA.
NOTE: Refer to page 223 if load causes
cylinder to extend.
*For part number and price for body only
contact your local Sun distributor.
200
CR to CH
100
VR to CR
0
7.5
15
22.5
30
Flow = GPM
20 GPM Maximum Total Flow with Load Holding Check Valve
CR
CH
CKEB-LCN
CBEA-LHN
2.03
1.60
.41 COFA-XEN
VR
Ports CH,
CR & VR
3/4” NPTF
SAE-12
3.25
VH
Assembly
Model Code*
YDED-LHN-AD
YDED-LHN-AL
Mounting Holes:
.42 diameter through hole
2 places.
VR
VH
CH
CR
4.50
2.25
1.75
.50
0
6.00
.50
0
5.50
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Pressure Drop
Regeneration diminishes progressively above
setting of CBEA.
NOTE: Refer to page 223 if load causes
cylinder to extend.
*For part number and price for body only
contact your local Sun distributor.
P = psi
300
200
CR to CH
VR to CR
100
VH to CH
0
5
10
15
20
Flow = GPM
NOTES: Page 50 for cartridge model CB**-*** and page 78 for CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
US Selected Assemblies Catalogue #999-901-192
225
0
.75
1.50
PRESSURE SENSITIVE REGENERATION APPLICATIONS
REGENERATION
60 GPM Maximum Regenerative Flow
CR
1.00” SAE Code 61
4-Bolt Flange Pattern
2 places.
3.00
CH
3.00
1.50
1.50
0
VR
7.00
CBGA-LHN
Ports CH,
CR & VR
Assembly
Model Code*
3/4” NPTF
1” NPTF
1 1/4” NPTF
SAE-12
SAE-16
YDGC-LHN-AD
YDGC-LHN-AE
YDGC-LHN-AF
YDGC-LHN-AL
YDGC-LHN-AM
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
5.06
1.94
VR
CH
0
0
7.00
4.00
.88
5.06
1.94
0
VR
CH
3.94
.88
CBGA-LHN
COHA-XEN
COHA-XEN
1.81
.75
CR
6.00
1.81
3.50
1.00 0
.75
CR
0
0
6.00
3.50
Mounting Holes:
(opposite side)
.375-16 UNC-2B x .62 deep.
Mounting Holes:
(opposite side)
.375-16 UNC-2B x .62 deep.
1.00 0
Pressure Drop
Regeneration diminishes progressively above
setting of CBGA.
NOTE: Refer to page 223 if load causes
cylinder to extend.
*For part number and price for body only
contact your local Sun distributor.
P = psi
300
200
CR to CH
VR to CR
100
15
0
30
45
60
Flow = GPM
50 GPM Maximum Regenerative Flow
CR
CH
1.25” SAE Code 61
4-Bolt Flange Pattern
2 places.
3.00
1.81
1.81
3.44
1.81
1.50
VR
VH
1.69
0
0
0 1.12 1.91
3.62 5.34 6.12 7.25
0
Ports CH,
CR & VR
3/4” NPTF
1” NPTF
1 1/4” NPTF
SAE-12
SAE-16
Assembly
Model Code*
YDGD-LHN-AD
YDGD-LHN-AE
YDGD-LHN-AF
YDGD-LHN-AL
YDGD-LHN-AM
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.94
2.88
CBGA-LHN
5.00
VR
0
0 1.12 1.94
0
1.56
COHA-XEN
.87
VH
CH
2.34
CKGB-LCN
Mounting Holes:
(opposite side)
.375-16 UNC-2B x .62 deep.
3.62 5.31 6.12 7.25
VR
VH
2.22
CBGA-LHN
CR
COHA-XEN
.87
CR
CH
4.44
Mounting Holes:
(opposite side)
.375-16 UNC-2B x .62 deep.
2.34
CKGB-LCN
Pressure Drop
300
Regeneration diminishes progressively above
setting of CBGA.
NOTE: Refer to page 223 if load causes
cylinder to extend.
*For part number and price for body only
contact your local Sun distributor.
P = psi
REGENERATIVE
Standard Assemblies: Line Mounted Regenerative Assemblies
200
CR to CH
100
VH to CH
0
12.5
25
37.5
50
Flow = GPM
NOTES: Page 50 for cartridge model CB**-*** and page 78 for CK*B-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
226
US Selected Assemblies Catalogue #999-901-192
REGENERATIVE
Standard Assemblies: Line Mounted Regenerative Assemblies
PRESSURE SENSITIVE REGENERATION APPLICATIONS
REGENERATION
120 GPM Maximum Regenerative Flow
CR
2.53
0
6.47
1.22
3.50
CH
VR
2.38
0
Ports CH,
CR & VR
Assembly
Model Code*
SAE 16
YDJC-LHN-AN
7.50
1.50
9.00
0
VR
CBIA-LHN
CH
COJA-XEN
CR
4.00
4.50
Mounting Holes:
.53 diameter through hole. 2 Places.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Pressure Drop
300
P = psi
Regeneration diminishes progressively above
setting of CBIA.
NOTE: Refer to page 223 if load causes
cylinder to extend.
*For part number and price for body only
contact your local Sun distributor.
200
100
CR to CH
VR to CR
0
30
60
90
Flow = GPM
120
240 GPM Maximum Regenerative Flow
CR
CH
2.00” SAE Code 61
4-Bolt Flange Pattern
3 places.
6.00
2.34
CBIA-LHN
2 places.
VR
Ports CH, CR, VR
Assembly
Model Code*
2” SAE C61
YDJC-LHN-AS
1.16
COJA-XEN
2 places.
3.00
0
0
.47
VR
Mounting Holes:
(opposite side)
.375-16 UNC-2B
x .62 deep.
CH
CR
5.94
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0 .50 2.38
5.00
7.62 9.50 10.00
Pressure Drop
P = psi
300
Regeneration diminishes progressively above
setting of CBIA.
NOTE: Refer to page 223 if load causes
cylinder to extend.
*For part number and price for body only
contact your local Sun distributor.
200
100
CR to CH
VR to CR
0
30
60
90
Flow = GPM
NOTES: Page 50 for cartridge model CB**-*** shows performance curves, technical tips, and options.
See page vii for technical information about line mount bodies including SAE flange pattern specifications.
Consult your local Sun Distributor or the Sun Web Site for other port sizes available in the bodies shown above.
Go to www.sunhydraulics.com for more product information and pricing.
US Selected Assemblies Catalogue #999-901-192
227
120
REGENERATIVE
Standard Assemblies: Line Mounted Regenerative Assemblies
NOTES
228
US Selected Assemblies Catalogue #999-901-192
TECHNICAL PRODUCT INFORMATION
DIRECT MOTOR MOUNTED ASSEMBLIES
Char-Lynn S Series
Applications
Applications
The gerotor type gear motor is used on a
large number of mobile and industrial
applications. It is often necessary to
incorporate valves in the circuit with the
motor to control the flow and pressure. It
may also be necessary to incorporate load
control valves in the circuit.
It is possible to mount line mounted valves
into the pipework feeding the motor, but
Sun offers a large range of valves that can
be bolted directly onto the motor interface.
This eliminates pipework and provides the
control directly at the motor.
The use of Sun cartridge valves in these
assemblies means that in the event of a
problem, it is a simple task to replace the
cartridge rather than have to replace the
complete valve.
US Selected Assemblies Catalogue #999-901-192
On the smaller size motors the same
gasket mounted face is used by at least
four different manufacturers of this type of
motor. The list below provides a quick
cross-reference.
Manufacturer (general motor type with
gasket mounted interface)
Eaton (S Type)
White (RS 06 and RS 46)
Parker/Ross/Nichols/Prince (TA, TB, TD,
NE, 110A, 130S, 400S)
On the specification in this catalogue for
the smaller size of motor, we are using
the Eaton reference number type as
they are probably the largest
manufacturer.
For the larger size of motors we are only
showing the Eaton reference of 2000
series and 4000 series.
229
Design Concepts and Features
The valve assemblies shown for all sizes
of motor are counterbalance valves and
cross line relief valves. The
counterbalance valves provide load
holding and load control while the cross
line relief valves provide over pressure
protection. The Sun counterbalance valves
provide excellent control with low
hysteresis and minimum leakage. The
relief valves are fast acting with minimum
overshoot for excellent protection.
On the smaller sizes of motor, Sun also
offers flow control, which can accurately
control the motor speed. The type of valve
offered is a pressure compensated flow
control valve but for more basic flow
control a simple restrictor valve can also
be used. Sun also has a further expanded
range of bolt on valve assemblies. Consult
the Sun factory or your local distributor
for further information.
DIRECT MOTOR MOUNT
Standard Assemblies
DIRECT MOTOR MOUNT
Standard Assemblies: Direct Motor Mounted Assemblies: Char-Lynn S Series Motors
SINGLE / DUAL CROSS-PORT RELIEF AND SINGLE COUNTERBALANCE APPLICATIONS
T-10A / T-11A Cavities
Go to www.sunhydraulics.com
for more product information.
MA
MB
DIRECT ACTING
PILOT RATIO 3:1
Function
Single Cross-Port Relief A to B
2
L Control
2.33 Max.
1
2.94
MA
MB
1.91
2
Ports
1, 2
Assembly
Model Code*
SAE 10
RDDA-L*N-ZFK
1
.72
MA
MB
1.35
3.15
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
2
4.50
Function
Single Cross-Port Relief B to A
L Control
2.33 Max.
1
2.94
MA
MB
Assembly
Model Code*
SAE 10
RDDA-L*N-ZFK
1
.72
MA
MB
1.35
3.15
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
A
1.91
2
Ports
1, 2
4.50
Function
B
Dual Cross-Port Relief
L Control
2.36 Max.
3.00
MA MB
A
2.25
Ports
A, B
Assembly
Model Code*
SAE 8
RDDA-L*N-YXB
MA
MB
B
0.75
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
1.38
3.50
L Control
2.36 Max.
Function
3.00
2.40
VB
Single Counterbalance on A
VB
VA
0.81
MA
L Control
1.28 Max.
MB
VA
MA
MB
0.25
0
0 0.25 0.81 1.38
2.31
3.69
VA
L Control
1.28 Max.
VA
MB
CBCA-LAN-ZPD
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
MA
MB
MA
SAE 10
Single Counterbalance on B
VB
0.81
Assembly
Model Code*
Function
3.00
2.40
VB
Ports
VA, VB
0.25
0
0 0.25 0.81 1.38
2.31
Ports
VA, VB
Assembly
Model Code*
SAE 10
CBCA-LAN-ZPB
3.69
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 2 for cartridge model RD*A-*** and page 50 for CB**-*** show performance curves, technical tips, and options.
See page 229 for technical information about bolt-on packages.
230
US Selected Assemblies Catalogue #999-901-192
SINGLE / DUAL COUNTERBALANCE AND DUAL FLOW CONTROL APPLICATIONS
T-11A / T-13A Cavities
Go to www.sunhydraulics.com
for more product information.
MA
MB
FULLY ADJUSTABLE PRESSURE
COMPENSATED WITH FREE FLOW CHECK
PILOT RATIO 3:1
L Control 3.75
1.28 Max.
0
2.38
Single Counterbalance on A
with Shuttle
0
VB
VA
Function
VA
S
.62
MB
SAE-4
Shuttle
Port
MA
VB
X
Control
.72
MB
S
SAE 10
CBCA-LAN-ZDV
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
0
2.38
Single Counterbalance on B
with Shuttle
0
X
Control
.72
VB
Assembly
Model Code*
2.38
3.00
3.75
VA
MA
Ports
VA, VB
VA
.62
MB
SAE-4
Shuttle
Port
VB
MA
MA
2.38
MB
3.00
L Control
1.28 Max.
0
Assembly
Model Code*
SAE 10
CBCA-LAN-ZDY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
3.68
2.31
Ports
VA, VB
Dual Counterbalance
0
VA
VB
VB
0.63
MA
L Control
1.28 Max.
MB
VA
2.37
MA
MB
Assembly
Model Code*
SAE 10
CBCA-LAN-YTA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3.00
2.38
L Control 0
1.28 Max.
VB
VA
Ports
VA, VB
Function
Dual Counterbalance with Shuttle
3.75
VA
.62
MB
S
SAE-4
Shuttle
Port
Ports
VA, VB
Assembly
Model Code*
SAE 10
CBCA-LAN-XTS
MA
VB
MA
2.38
MB
3.00
X Control
.72
VA
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
VB
0
2.38
3.44
0
VA
Dual Flow Control
Meter-out on A and B
0.59
MB
L Control
2.21 Max.
MA
MB
Ports
VA, VB
Assembly
Model Code*
SAE 10
FDBA-LAN-XWT
MA
VB
2.41
3.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 126 for cartridge model FD**-*** and page 50 for CB**-*** show performance curves, technical tips, and options.
See page 229 for technical information about bolt-on packages.
US Selected Assemblies Catalogue #999-901-192
231
DIRECT MOTOR MOUNT
Standard Assemblies: Direct Motor Mounted Assemblies: Char-Lynn S Series Motors
DIRECT MOTOR MOUNT
Standard Assemblies: Direct Motor Mounted: Char-Lynn S Series Motor
SINGLE FLOW CONTROL APPLICATIONS
T-13A Cavity
Go to www.sunhydraulics.com
for more product information.
MA
MB
FULLY ADJUSTABLE
VA
Function
Single Flow Control Bleed-Off
VB
Mounting Hole:
.50 diameter through hole.
0.25 0.60
0
2.75 2.40
0.62
0
0.25
MA
0.81
MA
MB
1.38
MA
MB
Ports
VA, VB
Assembly
Model Code*
SAE 10
NFCC-LCN-ZFZ
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
2.06
VA
VB
.75
2.25
L Control
1.06 Max.
VA
NOTES: Page 110 for cartridge model NF**-*** show performance curves, technical tips, and options.
See page 229 for technical information about bolt-on packages.
232
US Selected Assemblies Catalogue #999-901-192
DUAL CROSS-PORT RELIEF AND SINGLE COUNTERBALANCE APPLICATIONS
T-10A / T-2A Cavities
Go to www.sunhydraulics.com
for more product information.
MA
MB
DIRECT ACTING
PILOT RATIO 3:1
2.75
Function
0
0.75
Dual Cross-Port Relief
VA
1.28
VB
VB
MA
VA
0.66
MB
0
Mounting Hole:
.41 diameter through hole.
0
MA
MB
0.47
Ports
VA, VB
Assembly
Model Code*
SAE 10
RDDA-L*N-YWA
1.97
L Control
2.25 Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
3.00
3.50 3.03
1.34
0.47
0
Function
Single Counterbalance on A
0
VA
0.94
0
2.38
1.28
2.78 3.50
0
VB
0.47
L Control
1.57 Max.
VB
MB
0.94
1.34
MA
2.56
VA
3.03
CBEA-LAN
-117 0-Ring (x2)
Mounting Holes:
.41 diameter through holes,
.59 diameter x .38 deep. 3 places.
MB
MA
Ports
VA, VB
Assembly
Model Code*
SAE 12
CBEA-LAN-ZPG
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
Single Counterbalance on B
0
VA
0.94
0
2.38
VB
1.28
CBEA-LAN
0.47
0.94
VB
MB
2.78 3.50
0
1.34
MA
L Control
1.57 Max.
VA
2.56
3.03
-117 0-Ring (x2)
MB
MA
0
S
VA
Mounting Holes:
.41 diameter through holes,
.59 diameter x .38 deep. 3 places.
0.94
0 0.44
2.38
VB
1.28
2.78 3.50
0
Ports
VA, VB
Assembly
Model Code*
SAE 12
CBEA-LAN-ZPI
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
Single Counterbalance on A
with Shuttle
0.47
MB
L Control
1.57 Max.
VB
0.94
1.34
1.75
S
MA
2.56
VA
3.03
Ports
VA, VB
Assembly
Model Code*
SAE 12
CBEA-LAN-ZPM
CBEA-LAN
Mounting Holes:
.41 diameter through holes,
.59 diameter x .38 deep. 3 places.
-117 0-Ring (x2)
MA
MB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 2 for cartridge model RD*A-*** and page 50 for CB**-*** show performance curves, technical tips, and options.
See page 229 for technical information about bolt-on packages.
US Selected Assemblies Catalogue #999-901-192
233
DIRECT MOTOR MOUNT
Standard Assemblies: Direct Motor Mounted: Char-Lynn 2000 Series Motors
DIRECT MOTOR MOUNT
Standard Assemblies: Direct Motor Mounted: Char-Lynn 2000 Series Motors
SINGLE / DUAL COUNTERBALANCE APPLICATIONS
T-2A Cavity
Go to www.sunhydraulics.com
for more product information.
MA
MB
PILOT RATIO 3:1
0
0.94
0 0.44
2.38
1.28
L Control
1.57
S
VA
2.78 3.50
0
0.47
VB
0.94
VB
MB
Function
Single Counterbalance on B
with Shuttle
1.34
1.75
S
CBEA-LAN
MA
2.56
VA
Ports
VA, VB
Assembly
Model Code*
SAE 12
CBEA-LAN-ZPO
3.03
MB
MA
Mounting Holes:
.41 diameter through holes,
.59 diameter x .38 deep. 3 places.
-117 0-Ring (x2)
0
.094
0
2.38
1.28
L Control
1.57 Max.
VA
2.78 3.50
0
Function
Dual Counterbalance
0.47
VB
MB
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0.94
VB
1.34
MA
2.56
VA
3.03
CBEA-LAN
(x2)
MB
MA
0
.094
0 0.44
2.88
L Control
1.57 Max.
S
VA
Mounting Holes:
.41 diameter through holes,
.59 diameter x .38 deep. 3 places.
-117 0-Ring (x2)
1.28
2.78 3.50
0
Assembly
Model Code*
SAE 12
CBEA-LAN-YTC
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
Dual Counterbalance with Shuttle
0.47
VB
MB
Ports
VA, VB
VB
1.34
1.75
S
MA
VA
MA
MB
-117 0-Ring
(x2)
CBEA-LAN
(x2)
0.31
CSAD
3.03
Mounting Holes:
.41 diameter through holes,
.59 diameter x .38 deep. 3 places.
Ports
VA, VB
Assembly
Model Code*
SAE 12
CBEA-LAN-XYS
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 50 for cartridge model CB**-*** show performance curves, technical tips, and options.
See page 229 for technical information about bolt-on packages.
234
US Selected Assemblies Catalogue #999-901-192
DUAL CROSS-PORT RELIEF AND DUAL COUNTERBALANCE APPLICATIONS
T-10A / T-2A Cavities
A
Go to www.sunhydraulics.com
for more product information.
B
DIRECT ACTING
PILOT RATIOS 3:1
Function
Dual Cross-Port Relief
0.92
3.08
3.52
2.65
0.48 0
1.35
0
0
0.31
1.25
2.19
2.50
.75 diameter through holes,
2 places.
Mounting Holes:
40 diameter through holes,
8 places.
1.94
RDDA-L*N
RDDA-L*N
Assembly
Model Code*
RDDA-L*N-YVP
L Control
2.26 Max.
0
-214 O-Ring
4.00
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Mounting Holes:
.40 diameter through hole,
7 places.
Tapped holes x .87 deep.
M10 x 1.5-6H, 4 places.
3.00
Function
Dual Counterbalance on A and B
1.50
L Control
1.57 Max.
0
5.21
1.20
0
.75 SAE Code-61 4-bolt flange pattern, 4 places.
1.94
Ports
3/4” SAE C61
Assembly
Model Code*
CBEA-LAN-VZX/M
CBEA
Add modifier /T to order Ductile Iron for pressure
rating over 3000 psi.
0
4.33
6.50
0
2.17
-214 O-Ring, 2 places.
Mounting Holes:
.40 diameter through hole,
7 places.
Tapped holes x .87 deep.
M10 x 1.5-6H, 4 places.
3.00
Function
Dual Counterbalance on A and B with Shuttle
1.50
L Control
1.57 Max.
5.21
0
0.75
CSAA
1.20
0
.75 SAE Code-61 4-bolt flange pattern, 4 places.
2.43
Ports
3/4” SAE C61
Assembly
Model Code*
CBEA-LAN-VWZ
CBEA
0.56
0
6.50
4.33
3.34
Shuttle valve CSAA-BXN
external port .25-19 BSPP port
2.17
0
*Add modifier /T to order Ductile Iron for pressure
rating over 3000 psi.
-214 O-Ring,
2 places.
NOTES: Page 2 for cartridge model RD*A-*** and page 50 for CB**-*** show performance curves, technical tips, and options.
See page 229 for technical information about bolt-on packages.
US Selected Assemblies Catalogue #999-901-192
235
DIRECT MOTOR MOUNT
Standard Assemblies: Direct Motor Mounted: Char-Lynn 4000 Series Motors
DIRECT MOTOR MOUNT
Standard Assemblies: Direct Motor Mounted
NOTES
236
US Selected Assemblies Catalogue #999-901-192
TECHNICAL PRODUCT INFORMATION
DIRECT MOTOR MOUNTED ASSEMBLIES
Danfoss (OMP/OMR Series and OMT Series)
Applications
The Danfoss gerotor type gear motor is
used on a large number of mobile and
industrial applications. It is often
necessary to incorporate valves in the
circuit with the motor to control the flow
and pressure. It is also sometimes
necessary to incorporate load control
valves in the circuit.
The use of Sun cartridge valves in these
valve assemblies means that in the event of
a problem it is a simple task to replace the
cartridge rather than have to replace the
complete valve.
We are showing a range of bolt-on valve
assemblies for the two most common
ranges of Danfoss motors, the OMP/
OMR range and the OMT range.
It is possible to mount line-mounted
valves into the pipework feeding the motor
but Sun offers a large range of valves that
can be bolted directly onto the motor
interface. This eliminates pipework and
provides the control directly at the motor.
US Selected Assemblies Catalogue #999-901-192
Design Concepts and Features
The valve assemblies shown for all sizes
of motor are counterbalance valves and
cross line relief valves. The
counterbalance valves provide load
holding and load control while the cross
line relief valves provide protection from
over pressurisation. The Sun
counterbalance valves provide excellent
control with low hysteresis and minimum
leakage. The relief valves are fast acting
with minimum overshoot for excellent
protection.
On the smaller sizes of motor, Sun also
offers flow control, which can accurately
control the motor speed. The type of valve
offered is a restrictor type control valve
but for more accurate flow control a
pressure compensated valve can also be
used. Sun also has a further expanded
range of bolt on valve assemblies. Consult
your local Sun company or distributor for
further information.
237
DIRECT MOTOR MOUNT
Standard Assemblies
DIRECT MOTOR MOUNT
Standard Assemblies: Direct Motor Mounted: Danfoss (OMP/OMR Series)
SINGLE / DUAL CROSS-PORT RELIEF AND SINGLE COUNTERBALANCE APPLICATIONS
T-10A / T-11A Cavities
Go to www.sunhydraulics.com
for more product information.
A
B
DIRECT ACTING
PILOT RATIO 3:1
Function
Single Cross-Port Relief A to B
V2
V1
0
0.81 1.38 2.23 2.80 3.50
1.94
0.56
0
0
0.38
G
A
1.17
1.80
1.95
B
L Control
2.12 Max.
2.58
Ports
V1, V2
Guage
Port
SAE10
SAE-6
Assembly
Model Code*
RDDA-L*N-WVY
3.37
3.75
V1
A
V2
B
G
Mounting Holes:
.34 diameter through holes,
.53 diameter x .38 deep. 4 places.
-118 0-Ring (x2)
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
Single Cross-Port Relief B to A
V2
V1
Mounting Holes:
.34 diameter through holes,
.53 diameter x .38 deep. 4 places.
3.75
3.37
1.94
G
B
V2
1.17
Guage
Port
Assembly
Model Code*
SAE10
SAE-6
RDDA-L*N-WVS
A
L Control
2.12 Max.
1.95
1.80
Ports
V1, V2
0
V1
2.58
A
0.56
G
B
0.38
0
0
0.81 1.38
2.23 2.80 3.50
-118 0-Ring (x2)
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
V2
V1
0.81 1.38
0
2.23 2.80 3.50
L Control
2.31 Max.
0
0.38
G1
G2
A
1.17
B
1.80
Guage
Port
Assembly
Model Code*
SAE10
SAE-6
RDDA-L*N-WVP
L Control
2.12 Max.
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
V1
A
V2
B
1.95
2.58
Ports
V1, V2
Dual Cross-Port Relief
0.56 0
1.94
G1
3.37
3.75
G2
Mounting Holes:
.34 diameter through holes,
.53 diameter x .38 deep. 4 places.
-118 0-Ring (x2)
Function
V1
V2
V2
0
V1
0.91
2.44
0
0
0.79
L Control 0.50
1.16
Max.
V2
B
A
2.86
1.14
1.92
2.08
V2
3.06
3.50
4.00
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Single Counterbalance on A
V1
0.95
A
B
2.21 3.00
0
Mounting Holes:
.34 diameter through holes,
.53 diameter x .38 deep. 4 places.
-118 0-Ring (x2)
Ports
V1, V2
Assembly
Model Code*
SAE10
CBCA-LAN-WZH
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
V2
-118 0-Ring (x2)
V1
V2
0
0.79
2.21 3.00
Single Counterbalance on B
0
V1
V1
1.14
0.50
V1
0.95
A
L Control 1.92
2.08
B
A
B
V2
1.16
Max.
0
0
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES:
0.91
2.44
3.06
3.50
4.00
Mounting Holes:
.34 diameter through holes,
.53 diameter x .38 deep. 4 places.
Ports
V1, V2
Assembly
Model Code*
SAE10
CBCA-LAN-WZE
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Page 2 for cartridge models RD*A-*** and page 50 for CB**-*** show performance curves, technical tips, and options.
See page 229 for technical information about bolt-on packages.
238
US Selected Assemblies Catalogue #999-901-192
SINGLE / DUAL COUNTERBALANCE APPLICATIONS (SHUTTLES)
T-11A Cavity
Go to www.sunhydraulics.com
for more product information.
A
B
PILOT RATIO 3:1
-118 0-Ring (x2)
0
0.56 0.91
0
2.44
20,1 35,6 56,1 76,2
0
L Control
V1
V2
V2
V1
0.50
1.16
Max.
V2
B
A
1.14
1.92
2.08
S
B
V1
0.95
A
V2
3.06
3.50
0.39
Port ‘S’
SAE-4
in cartridge hex.
0 0.56
Mounting Holes:
.34 diameter through holes,
.53 diameter x .38 deep. 4 places.
2.44
0.91
0
0.79
0.50
V2
1.40
2.21 3.00
0
L Control
V1
Ports
V1, V2
Assembly
Model Code*
SAE10
CBCA-LAN-WZS
4.00
-118 0-Ring (x2)
V2
Function
Single Counterbalance on A
with Shuttle
A
V1
0.95
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
Single Counterbalance on B
with Shuttle
V1
2.86
B
A
1.92
2.08
1.16
Max.
B
V2
V1
0.39
3.06
3.50
0
Mounting Holes:
.34 diameter through holes,
.53 diameter x .38 deep. 4 places.
0
2.44
0.91
L Control
V2
V1
0.79
Function
2.21 3.00
Dual Counterbalance
V2
V2
3.06
3.50
4.00
B
A
Mounting Holes:
.34 diameter through holes,
.53 diameter x .38 deep. 4 places.
-118 0-Ring (x2)
0.91
0
2.44
L Control
S
V1
V2
V1
1.16
Max.
B
2.86
V2
V2
3.06
3.50
Port ‘S’
SAE-4
in cartridge hex.
A
0 0.56
Mounting Holes:
.34 diameter through holes,
.53 diameter x .38 deep. 4 places.
0.91
V2
A
0.65
B
2.86
SAE10
CBCA-LAN-WZV
0.39
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Shuttle Only
V1
1.14
V2
V2
4.00
Port ‘S’
Mounting Holes:
SAE-4
.34 diameter through holes,
in cartridge hex. .53 diameter x .38 deep. 4 places.
239
Ports
V1, V2
Assembly
Model Code*
SAE10
CSAA-BXN-WZY
3.06
3.50
NOTES: Page 50 for cartridge models CB**-*** show performance curves, technical tips, and options.
See page 229 for technical information about bolt-on packages.
US Selected Assemblies Catalogue #999-901-192
Assembly
Model Code*
0.79 1.40 2.21 3.00
1.92
2.08
S
A
Ports
V1, V2
0
V1
B
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
0
2.44
0.50
V1
CBCA-LAN-WZL
1.14
1.92
2.08
-118 0-Ring (x2)
V2
SAE10
4.00
0.39
B
Assembly
Model Code*
V1
0.95
A
0.79 1.40 2.21 3.00
0
0.50
V2
Ports
V1, V2
Function
Dual Counterbalance with Shuttle
-118 0-Ring (x2)
0 0.56
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
1.92
2.08
1.16
Max.
2.86
CBCA-LAN-WZP
V1
0.95
B
SAE10
0
0.50
A
V1
V2
Assembly
Model Code*
4.00
Port ‘S’
SAE-4
in cartridge hex.
0
Ports
V1, V2
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
DIRECT MOTOR MOUNT
Standard Assemblies: Direct Motor Mounted: Danfoss (OMP/OMR Series)
DUAL FLOW CONTROL APPLICATIONS
T-5A Cavity
Go to www.sunhydraulics.com
for more product information.
A
B
FULLY ADJUSTABLE PRESSURE COMPENSATED FLOW
CONTROL WITH REVERSE FREE FLOW CHECK
Function
V1
V2
2.21
0.91
0.79
2.09
3.00
L Control
2.29 Max.
0
2.00
0
0.50
0.69
V2
A
V1
1.92
B
Dual Flow Control
Meter-in on A and B
0.62 0
0
2.08
A
B
3.31
3.50
L Control
2.31 Max.
Mounting Holes:
.34 diameter through holes,
.53 diameter x .38 deep. 4 places.
4.00
Ports
V1, V2
Assembly
Model Code*
SAE10
FDCB-LAN-WZB
-118 0-Ring (x2)
*Add modifier /S to order Ductile Iron for pressure rating over
3000 psi.
Function
V1
V2
0.91
0
0
0.79
2.21
2.09
3.00
Dual Flow Control
Meter-out on A and B
L Control
2.29 Max
2.00
0.50
0.69
2.08
B
0
0
DIRECT MOTOR MOUNT
Standard Assemblies: Direct Motor Mounted: Danfoss (OMP/OMR Series)
A
1.92
B
A
3.31
3.50
L Control
2.31 Max.
4.00
Mounting Holes:
.34 diameter through holes,
.53 diameter x .38 deep. 4 places.
-118 0-Ring (x2)
Ports
V1, V2
Assembly
Model Code*
SAE10
FDCB-LAN-WXH
*Add modifier /S to order Ductile Iron for pressure rating over
3000 psi.
NOTES: Page 126 for cartridge models FD*B-*** show performance curves, technical tips, and options.
See page 229 for technical information about bolt-on packages.
240
US Selected Assemblies Catalogue #999-901-192
SINGLE / DUAL CROSS-PORT RELIEF AND SINGLE COUNTERBALANCE APPLICATIONS
T-10A / T-2A Cavities
Go to www.sunhydraulics.com
for more product information.
B
A
DIRECT ACTING
PILOT RATIO 3:1
V2
0
0
-123
0-Ring
(x2)
1.40
1.32
1.81
0.97
0.91
B
V1
1.94
V2
V1
0.42
4.00
3.64
2.94
1.21 1.94 2.06
0 0.36
0
Function
Single Cross-Port Relief A to B
A
2.31
A
B
Ports
V1, V2
Assembly
Model Code*
SAE 12
RDDA-L*N-WLV
3.50
Mounting Holes:
.42 diameter through holes,
4 places.
L Control
2.19 Max.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
2.94
1.21 1.94 2.06
0 0.36
0
0
-123
0-Ring
(x2)
0.91
1.32
V2
0.97
Function
Single Cross-Port Relief B to A
0
B
V1
1.94
V2
V1
0.42
4.00
3.64
1.40
1.81
A
2.31
A
B
Ports
V1, V2
Assembly
Model Code*
SAE 12
RDDA-L*N-WMV
3.50
Mounting Holes:
.42 diameter through holes,
4 places.
L Control
2.19 Max.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
0 0.36
0
V1
0.97
0
0
-123
0-Ring
(x2)
0.91
B
1.32
V1
1.94
3.64
V2
V1
0.42
Function
Dual Cross-Port Relief
4.00
2.94
1.21 1.94 2.06
1.40
1.81
A
2.31
A
B
Ports
V1, V2
Assembly
Model Code*
SAE 12
RDDA-L*N-WLY
L Control
2.19 Max.
Mounting Holes:
.42 diameter through holes,
4 places.
L Control
2.19 Max.
*Add modifier /S to order Ductile Iron for pressure rating
over 3000 psi.
2.75
1.44
0
0
V2
V1
0.72
0
1.62
Function
Single Counterbalance on A
2.60
1.69 3.00
0
0.36
1.00
V1
A
1.95
2.07
L Control
1.66 Max.
B
3.00
V2
4.00
3.64
B
A
Mounting Holes:
.42 diameter through holes,
.69 diameter x .35 deep. 4 places.
-123 0-Ring (x2)
2.75
1.44
0
0
0
V2
V1
1.00
0
0.36
L Control
1.66 Max.
A
0.72
1.62
Ports
V1, V2
Assembly
Model Code*
SAE 12
CBEA-LAN-WKH
*Add modifier /S to order Ductile Iron for
pressure rating over 3000 psi.
Function
Single Counterbalance on B
2.60
1.69 3.00
2.07
V1
1.95
4.00
B
3.00
V2
3.64
B
A
-123 0-Ring (x2)
Mounting Holes:
.42 diameter through holes,
.69 diameter x .35 deep. 4 places.
Ports
V1, V2
Assembly
Model Code*
SAE 12
CBEA-LAN-WKL
*Add modifier /S to order Ductile Iron for
pressure rating over 3000 psi.
NOTES: Pages 2 for cartridge models RD*A-*** and page 50 for CB**-*** show performance curves, technical tips, and options.
See page 229 for technical information about bolt-on packages.
US Selected Assemblies Catalogue #999-901-192
241
DIRECT MOTOR MOUNT
Standard Assemblies: Direct Motor Mounted: Danfoss (OMT Series)
DIRECT MOTOR MOUNT
Standard Assemblies: Direct Motor Mounted: Danfoss (OMT Series)
SINGLE / DUAL COUNTERBALANCE APPLICATIONS (SHUTTLES)
T-2A Cavity
Go to www.sunhydraulics.com
for more product information.
B
A
PILOT RATIO 3:1
Function
V2
-123 0-Ring (x2)
V1
2.75
1.44
0
0
S
0.72
0
0.36
0
1.00
V1
A
1.65
B
B
A
Single Counterbalance on A
with Shuttle
2.60
1.69 3.00
1.62
2.07
L Control
1.66 Max.
3.00
V2
3.64
4.00
Port ‘S’
SAE-4
in cartridge hex.
0.69
Mounting Holes:
.42 diameter through holes,
.69 diameter x .35 deep. 4 places.
Ports
V1, V2
Assembly
Model Code*
SAE 12
CBEA-LAN-WKP
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
V2
V1
-123 0-Ring (x2)
2.75
S
0
0
0.72
1.62
Single Counterbalance on B
with Shuttle
2.60
1.69 3.00
0
0.36
0
1.00
V1
A
1.95
B
2.07
B
A
3.00
V2
3.64
L Control 4.00
1.66 Max.
Mounting Holes:
.42 diameter through holes,
.69 diameter x .35 deep. 4 places.
Port ‘S’ SAE-4
in cartridge hex.
Ports
V1, V2
Assembly
Model Code*
SAE 12
CBEA-LAN-WKS
0.69
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
Function
V2
V1
-123 0-Ring (x2)
2.75
1.44
0.72
0
0
0
0.36
0
1.00
V1
A
1.95
B
A
Dual Counterbalance
2.60
1.69 3.00
1.62
2.07
B
3.00
V2
3.64
L Control 4.00
1.66 Max.
Mounting Holes:
.42 diameter through holes,
.69 diameter x .35 deep. 4 places.
V2
V1
2.75
1.44
0
0
0.72
1.62
1.00
CBEA-LAN-WKV
66,0
42,9 3.00
V1
A
1.95
A
SAE 12
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
0
0.36
0
B
Assembly
Model Code*
Function
Dual Counterbalance with Shuttle
S
-123 0-Ring (x2)
Ports
V1, V2
2.07
B
3.00
3.64
L Control
42,2 Max.
Port ‘S’ SAE-4
in cartridge hex.
V2
4.00
0.69
Mounting Holes:
.42 diameter through holes,
.69 diameter x .35 deep. 4 places.
Ports
V1, V2
Assembly
Model Code*
SAE 12
CBEA-LAN-WKY
*Add modifier /S to order Ductile Iron for pressure
rating over 3000 psi.
NOTES: Page 50 for cartridge model CB**-*** show performance curves, technical tips, and options.
See page 229 for technical information about bolt-on packages.
242
US Selected Assemblies Catalogue #999-901-192
General Information
Page
Cartridge Control Options
244
Cartridge Control Kits
245
4
Cavity Plugs
246
3
2
1
Solenoid Electrical Connector Options
248
Pressure Drop Data Chart
249
Cartridge Cavities and Cavity Tools
250
US Selected Assemblies Catalogue #999-901-192
243
General Information
CARTRIDGE CONTROL OPTIONS
General Purpose Controls
L Standard Screw Adjustment
O-ring seal on adjust screw. Adjust
screw positively retained. Overset
protection-pilot spring cannot go
solid.
Key Lock Kit
Optional adjustment Key Lock Cover Kit for L controls
allows adjustment to be locked with a key to prevent
unauthorized changes in valve setting. Adjustment easily
accessible when lock assembly is removed.
2.44"
Requires replacement of
1.66"
standard locknut with special
locknut which accepts
assembly, and new wire
3.12"
stop ring for overset
to remove key or cover
protection.
5/32” Hex
9/16” Hex
K Handknob with Lock Knob
Handknob and lock knob added to L
control. Sun handknob kits for field
conversion are available. See
cartridge control kits.
5/32” Hex
O Handknob with Panel Mount
Special threaded cartridge hex body
with panel nut for mounting cartridge
through access hole in control panel.
Handknob and lock knob included.
1.25” diameter
Zero Indicator
Panel
Hole
Panel Hole:
Series 1 cartridges
Series 2 cartridges
1.17”
diameter
H Calibrated Handknob with Detent Lock
Fully calibrated handknob for flow control cartridges.
40 radial calibrations per turn. Moveable zero indicator.
(Minor disassembly required.) Rising detented locking
collar positively locks adjustment knob against vibration
or accidental tampering. Any desired setting may be
recorded and repeated. U.S. Patent #4,577,831
5/32” Hex
.75” dia.
1.00” dia.
.09”
.30”
Dia.
Locking Collar
Rising Stem
Counts Full Turns
C Tamper Resistant Factory Set
Diameter 1.13” Dia. 1.38” Dia. 1.62” Dia. 1.62” Dia.
Steel cover press-fits onto L control
cartridge shoulder. Valves may be
ordered in this configuration. Specify
pressure setting on order. Setting
stamped on cartridge hex. Kits for
field conversion are available. See
cartridge control kits.
Series
1
2
3
4
NCCB
NCEB
NCFB
NCGB
NCCC
NCEC
NCFC
NCGC
NFCC
NFDC
NFEC
NFFC
NFCD
NFDD
NFED
NFFD
FDBA
FDCB
FDEA
FDFA
Special Purpose Controls (for use in systems where adjustment is seldom changed after installation)
5/32” Hex
J Socket Head Set Screw with Cap
Stem seal O-ring under locknut.
Adjustment screw is not retained. No
overset protection.
F Wrench Adjustment
Stem seal O-ring under locknut.
Adjusting screw is not retained.
Overset protection-pilot spring cannot
go solid.
9/16” Hex
Counterbalance Valves
Series 1, 2, 3: 5/32" Hex
Series 4: 7/32" Hex
L Standard Leakproof
Screw Adjustment.
O-ring seal on adjust
screw.
All Sun counterbalance cartridges are built with
a leakproof adjustment (O-ring seals on the adjusting
screw) but are not designed for frequent adjustment in the field.
Cartridges that are factory pre-set by Sun to a customer
specified pressure setting are available and can be installed
directly on a machine without the need for further adjustment.
Series 1, 2, 3: 9/16" Hex
Series 4: 3/4" Hex
C Tamper Resistant Factory Set
See C Control description above.
244
US Selected Assemblies Catalogue #999-901-192
General Information
CARTRIDGE CONTROL KITS
Service Kit
Number
Description
Adjustment
Screw Kit
991-006
Use specifically with
Control/Cartridge
Description
Locknut
All F controls
Adjust
Screw
Seal
Seal
Cap
Adjustment
Screw Kit
991-010
All J controls
Tamper
Resistant Cover
991-000
991-004
991-001
991-002
991-003
For all Sun cartridges with L
adjustment
Series 0 - 3/4” (19,0 mm) hex
hex
Series 1 - 7/8” (22,2 mm) hex
Series 2 - 1 1/8” (28,6 mm) hex
Series 3 - 1 1/4” (31,8 mm) hex
Series 4 - 1 5/8” (41,0 mm) hex
Adjust
Screw
Locknut
Adapter
Locknut
Key
Use this kit to adapt all L
controls to K controls (except
Series 0 and counterbalance
cartridges).
991-222
K control for Series 0
Panel
Handknob Kit
991-215
O controls
All Series 1 cartridges
7/8” (22,2 mm) hex M20
thread
Panel
Handknob Kit
991-216
O controls
All Series 2 cartridges
1 1/8” (28,6 mm) hex
1”-14 thread
H
Calibrated
Handknob Kit
H controls
All series of flow controls
991-219
FDCB , NCEB, NCEC ,
NFDC, NFDD only
991-220
FDEA, FDFA, NCFB,
NCFC, NCGB, NCGC,
NFEC, NFED, NFFC,
NFFD only
991-221
FDBA , NCCB , NCCC ,
NFCC, NFDC only
Lockwire
911-012
All M, Q and R controls
(except solenoid operated
cartridges).
Adjustment
For cartridge models:
Screw Kit
CKCA L**CKCD L**
991-112-003 Viton CKCB L**CPCA L**
991-112-007 Buna-N CKCC L**
Adjustment
For cartridge models:
Screw Kit
CKEA L**CKED L**
991-212-003 Viton CKEB L**CPEA L**
991-212-007 Buna-N CKEC L**
US Selected Assemblies Catalogue #999-901-192
1. Adjust valve to desired setting
and tighten locknut.
2. Using an arbor press or a soft
hammer, install cover until it
seats on cartridge hex.
3. Cover is a press fit on
cartridge shoulder.
Cover
For all Sun cartridges with L
adjustment (except Series 0
and counterbalance
cartridges).
K
Handknob Kit
991-211
To assure a complete seal on the
stem - release all pressure on the
cartridge after setting. Then...
tighten locknut (and cap, on J).
Tamper Resistant Cover
For all Sun cartridges with
L-adjustment
Lock
Assembly
Key Lock Kit
993-008
Notes
Wire Stop Ring
Handknob
Assembly
Handknob
Assembly
Lock
Knob
1. Remove original wire stop
ring and locknut.
2. Thread on the adapter locknut
and install new wire stop ring
through slot provided.
3. Adjust valve to desired setting
and tighten adapter locknut.
4. Slide lock assembly over
adapter, lock and remove key.
Only cartridges date stamped
“41” or later and originally
supplied with plastic knobs. Lock
knob snaps onto locknut
furnished on cartridge.
Lock
Knob
Only for cartridges originally
supplied with an H handknob.
Valves can not be modified in the
field.
Handknob
Locking Wire
Manual
Release
Screw
Lockring
O-ring
Exsisting
Cartridge
Note: The H control is
Only available for the cartridges
shown to the left.
Lead Seal
Back-up
Ring
Only cartridges date stamped
“62” or earlier.
Locknut
245
Seal
General Information
CAVITY PLUGS
It is sometimes desirable to remove a Sun cartridge valve and still maintain the integrity of
the hydraulic system. This may be necessitated by the need to flush a system after repairs or
a piping change, or to change an operating function in the circuit. For these requirements,
Sun offers two styles of cavity plugs - all ports blocked and main ports open to flow.
Plugs for Two Port Cavities:
All Ports Open
P
0
T-162A XZOA-XX*
XZCA-XX*
T-10A
XFCA-XX*
Series
1
2
2
1
All Ports Blocked
Cavity Plug
Cavity Model
Code
T-8A XAOA-XX*
T-13A
T-3A
T-5A
Cavity Plug
Model Code
XACA-XX*
XFOA-XX*
XGCA-XX*
2
XCCA-XX*
XCOA-XX*
XDCA-XX*
3
T-16A XIOA-XX*
XICA-XX*
4
T-18A XKOA-XX*
XKCA-XX*
1
Plugs for Three Port Cavities
Ports 1 to 2 Open
Port 3 Blocked
3
2
1
Series
Cavity
P
T-9A
Cavity Plug
Model Code
All Ports Blocked
Cavity Plug
Model Code
XAOB-XX*
XACB-XX*
0
T-163A XZOB-XX*
XZCB-XX*
1
T-11A XEOA-XX*
XECA-XX*
2
T-2A
XBOA-XX*
XBCA-XX*
3
T-17A XHOA-XX*
XHCA-XX*
4
T-19A XJOA-XX*
XJCA-XX*
3
2
1
Plugs for Four Port Cavities (Internal Locating Shoulder)
Ports 1 to 2 Open
Port 3 and 4 Blocked
4
Series
3
2
1
Cavity
Cavity Plug
Model Code
All Ports Blocked
Cavity Plug
Model Code
1
T-21A XMOA-XX*
XMCA-XX*
2
T-22A XNOA-XX*
XNCA-XX*
3
T-23A XPOA-XX*
XPCA-XX*
4
T-24A XQOA-XX*
XQCA-XX*
4
3
2
1
*Insert in the seventh position model code digit N to order Buna-N seals or V to order Viton seals.
246
US Selected Assemblies Catalogue #999-901-192
General Information
CAVITY PLUGS
Plugs for Four Port Cavities (External Locating Shoulder)
All Ports Open
4
Series
3
2
Cavity
Cavity Plug
Model Code*
All Ports Blocked
Cavity Plug
Model Code*
1
T-31A XFOA-XX*
XRCA-XX*
2
T-32A XCOA-XX*
XSCA-XX*
3
T-33A XIOA-XX*
XTCA-XX*
4
T-34A XKOA-XX*
XVCA-XX*
4
3
2
1
1
Plugs for Six Port Cavities
6
Ports 1, 2, 3 and 4 Open
Ports 5 and 6 Blocked
5
Series
4
3
2
Cavity
Cavity Plug
Model Code*
All Ports Blocked
Cavity Plug
Model Code*
1
T-61A XMOA-XX*
XRCC-XX*
2
T-62A XNOA-XX*
XSCC-XX*
3
T-63A XPOA-XX*
XTCC-XX*
4
T-64A XQOA-XX*
XVCC-XX*
6
5
4
3
2
1
1
Cavity Adaptor (Adapts Waterman 12-2 Cavity to the Sun T-8A Cavity)
All Ports Open
Cavity
2
12-2
Cavity Plug
Model Code*
XAAA-8X*
1
*Insert in the seventh position model code digit N to order Buna-N seals or V to order Viton seals.
US Selected Assemblies Catalogue #999-901-192
247
General Information
SOLENOID ELECTRICAL CONNECTOR OPTIONS
Pilot Flow Solenoid Valves: DAAA, DBAA
ISO / DIN 43650
SAE J858-A
Twin Lead
Description
Coil only
part number
Coil only part
number
Coil only part
number
115 V AC
50/60 Hz
760-211
N/A
N/A
230 V AC
50/60 Hz
760-223
N/A
N/A
6 V DC
760-206
760-506
N/A
12 V DC
760-212
760-512
760-712
24 V DC
760-224
760-524
760-724
36 V DC
760-236
N/A
N/A
48 V DC
760-248
N/A
N/A
Full Flow Solenoid Valves: DLDA, DTDA, DMDA, DNDA
ISO / DIN 43650
Twin Lead
AMP® Junior Timer
Description
Coil only part
number
Coil only part
number
Coil only part
number
115 V AC
50/60 Hz
770-211
N/A
N/A
230 V AC
50/60 Hz
770-223
N/A
N/A
12 V DC
770-212
770-612
770-712
24 V DC
770-224
770-624
770-724
48 V DC
770-248
770-648
770-748
AMP® is a registered trademark.
248
US Selected Assemblies Catalogue #999-901-192
General Information
ORIFICE PRESSURE DROP DATA
No allowance has been made for viscosity effects, or regain of pressure downstream.
Orifice diameter, inches
1
64
4000
1
32
1
16
3
32
3000
2500
Pressure Drop – psi
2000
1500
1
8
1000
500
5
32
3
16
200
These charts are based on
the formula:
7
32
100
Q ∅ C ± A ± 2 gH
Where:
Q = Flow in Cu. Ft. per Sec.
C = Orifice Coefficient
A = Area of Orifice in Sq. Ft.
H = Pressure Head in Ft.
50
25
10
1
4
3
8
0
1
2
3
4
5
6
7
8
9
10
1
2
Flow – GPM
Specify Gravity of Fluid = .895
This equation becomes
Q(GPM) = 24.12 ± A(sq.in.) ±
Pressure Drop (psi) when C ∅ 0.6
4000
3
32
Orifice diameter, inches
5
32
1
8
3
16
7
32
1
4
5
16
3000
2500
Pressure Drop – psi
2000
1500
3
8
1000
7
16
500
1
2
9
16
200
100
5
8
50
25
10
7
8
3
4
1
0
10
20
30
40
50
Flow – GPM
US Selected Assemblies Catalogue #999-901-192
5
16
249
60
70
80
90
100
7
16
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES P
T-8A
2 Port Sun Cavity
Minimum Clearance Distances:
.453
Manifold
Edge
.861 Minimum Hex
Extension
1.250
Socket Wrench Clearance
(not included on Form Drill)
.703
.705
.219 Maximum L.S.
Depth without Socket
Clearance
.136
o
60
1.000
0.000
Socket
Diameter
Hex Point CLto CL *
0.000 Locating Shoulder
.656
.657
.141
M16 x 1.5-6H
.570
.574
.391 Minimum Full Thread
Bottom Tap Required
.531
.437
.439
.750
.754
Deep Socket*
(.031 minimum below surface)
.188
Maximum
.438 Port 2 Centerline
Cartridge Nose
Support
Port
1
.250
Maximum
* See respective Pilot Stage Cartridge Outline Drawing for Deep Socket and
Hex Point clearance centerline dimensions
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-008-001
994-008-101
TD-8A
Form Reamer
995-008-001
995-008-101
TR-8A
Metric Tap
998-991
998-991-101
M16x1.5-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
7/8” Hex Deep Socket:
Cavity Diameters to be concentric to threads within .002.
Sun P/N: 998-100-006, Snap-On P/N: SIML280
© SUN Hydraulics Corporation
T-9A
3 Port Sun Cavity
.861 Minimum Hex
Extension
1.250
Minimum Clearance Distances:
(not included on Form Drill)
.703
.705
Deep Socket*
.219 Maximum L.S.
Depth without Socket
Clearance
o
60
1.000
.136
0.000 Locating Shoulder
0.000
.656
.657
.141
M16 x 1.5-6H
.570
.574
.391 Minimum Full Thread
Bottom Tap Required
.531
Socket
Diameter
(.031 minimum below surface)
.188
.125
Maximum
.812 Port 2 Centerline
.875
.437
.439
Port
1
.250
Maximum
Hex Point CLto CL *
Maximum
.438 Port 3 Centerline
.500
.502
1.095
1.100
.453
Manifold
Edge
Socket Wrench Clearance
Cartridge Nose
Support
* See respective Pilot Stage Cartridge Outline Drawing for Deep Socket and
Hex Point clearance centerline dimensions.
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-009-001
994-009-101
TD-9A
Form Reamer 995-009-001
995-009-101
TR-9A
Metric Tap
998-991
998-991-101
M16x1.5-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
7/8” Hex Deep Socket:
Sun P/N: 998-100-006, Snap-On P/N: SIML280
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
US Selected Assemblies Catalogue #999-901-192
250
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 0
T-162A
2 Port Sun Cavity
1.125
Minimum Clearance Distances:
Socket Wrench Clearance
(included on Form Drill)
.453
Manifold
Edge
.812 Minimum Hex
Extension
.969 Deep Socket
.484
.936
.940
.273
o
45
(2) Places
Socket
Diameter
.703
.705
0.000
.156
(.031 minimum below surface)
.656
.657
.531
Maximum
M16x1.5-6H
.531 Minimum Full Thread
25
.641 Port 2 Centerline
o
.570
.574
.908
1.219
1.222
.875 Hex Point CLto CL
0.000 Locating Shoulder
.515
.517
1.297
Minimum Depth
of .406 for
Working Parts
Clearance
Cartridge Nose
Support
Port
1
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-162-001
994-162-101
TD-162A
Form Reamer
995-162-001
995-162-101
TR-162A
Metric Tap
998-991
998-991-101
M16x1.5-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
3/4” Hex Deep Socket:
.406
Maximum
Sun P/N: 998-100-005, Snap-On P/N: S241
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
T-163A
3 Port Sun Cavity
1.125
Minimum Clearance Distances:
Socket Wrench Clearance
(included on Form Drill)
.936
.940
.484
Manifold
Edge
.969 Deep Socket
1.188 Minimum Hex
Extension
o
30
o
45
(2) Places
.906
.696
.609 Minimum Surface
from L.S.
.312 Maximum
.703
.705
Socket
Diameter
.875 Hex Point CLto CL
.188 Port 3 Centerline
0.000
.156
0.000 Locating Shoulder
.656
.657
.531
M16x1.5-6H
Maximum
.531 Minimum Full Thread
.641 Port 2 Centerline
o
.908
1.219
1.222
.570
.574
25
.515
.517
1.297
Minimum Depth
of .406 for
Working Parts
Clearance
Port
1
Cartridge Nose
Support
.406
Maximum
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-163-001
994-163-101
TD-163A
Form Reamer 995-163-001
995-163-101
TR-163A
Metric Tap
998-991
998-991-101
M16x1.5-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
3/4” Hex Deep Socket:
Sun P/N: 998-100-005, Snap-On P/N: S241
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
251
US Selected Assemblies Catalogue #999-901-192
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 1
T-10A
2 Port Sun Cavity
1.250
Minimum Clearance Distances:
Socket Wrench Clearance
(not included on Form Drill)
.688 Minimum Hex
Extension
1.000
o
45
(3) Places
.156
.859
.861
Socket
Diameter
0.000 Locating Shoulder
.812
.814
1.062 Hex Point CLto CL
(.031 minimum below surface)
.875
M20x1.5-6H
Maximum
.500 Minimum Full Thread
.812 Port 2 Centerline
.730
.734
1.266
1.567
1.572
.687
.689
1.810
Minimum Depth of
.531 for Working
Parts Clearance
1.125 Deep Socket
.438 Maximum L.S.
Depth without Socket
Clearance
.227
0.000
.562
Manifold
Edge
Cartridge Nose
Support
Port
1
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-010-001
994-010-101
TD-10A
Form Reamer
995-010-001
995-010-101
TR-10A
Metric Tap
998-998
998-998-101
M20x1.5-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
7/8” Hex Deep Socket:
Sun P/N: 998-100-001, Snap-On P/N: S281
.531
Maximum
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
T-13A
2 Port Sun Cavity
1.250
Minimum Clearance Distances:
Socket Wrench Clearance
(not included on Form Drill)
.562
Manifold
Edge
.688 Minimum Hex
Extension
.998
1.002
1.125 Deep Socket
o
45
(3) Places
.438 Maximum L.S.
Depth without Socket
Clearance
.227
0.000
.859
.861
.812
.814
.156
1.062 Hex Point CLto CL
(.031 minimum below surface)
.688
Maximum
M20x1.5-6H
.500 Minimum Full Thread
.719 Port 2 Centerline
.730
.734
1.078
1.380
1.385
Socket
Diameter
0.000 Locating Shoulder
.687
.689
1.59
Minimum Depth of
.531 for Working
Parts Clearance
Cartridge Nose
Support
Port
1
7/8” Hex Deep Socket:
.531
Maximum
Sun P/N: 998-100-001, Snap-On P/N: S281
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
US Selected Assemblies Catalogue #999-901-192
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-013-001
994-013-101
TD-13A
Form Reamer
995-013-001
995-013-101
TR-13A
Metric Tap
998-998
998-998-101
M20x1.5-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
252
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 1
T-11A
3 Port Sun Cavity
1.250
Minimum Clearance Distances:
Socket Wrench Clearance
(not included on Form Drill)
.594
Manifold
Edge
1.188 Minimum Hex
Extension
1.000
.938 Maximum L.S.
Depth without Socket
Clearance
o
45
(3) Places
.688 Minimum Surface
from L.S.
.422 Maximum
.721
.859
.861
0.000
.156
1.125 Deep Socket
1.062 Hex Point CLto CL
.219 Port 3 Centerline
0.000 Locating Shoulder
.812
.814
.688
M20x1.5-6H
Maximum
.500 Minimum Full Thread
.719 Port 2 Centerline
.730
.734
1.078
.687
.689
1.380
1.385
Socket
Diameter
1.59
Minimum Depth of
.531 for Working
Parts Clearance
Cartridge Nose
Support
Port
1
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-011-001
994-011-101
TD-11A
Form Reamer
995-011-001
995-011-101
TR-11A
Metric Tap
998-998
998-998-101
M20x1.5-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
7/8” Hex Deep Socket:
Sun P/N: 998-100-001, Snap-On P/N: S281
.531
Maximum
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
T-21A
4 Port Sun Cavity
1.250
Minimum Clearance Distances:
Socket Wrench Clearance
(not included on Form Drill)
.625
Manifold
Edge
1.781 Minimum Hex
Extension
1.000
o
1.438 Maximum L.S.
Depth without Socket
Clearance
1.188 Minimum Surface
from L.S.
.250 Maximum
45
(4) Places
1.211
.889
.891
Socket
Diameter
.812 Port 4 Centerline
.671
1.062 Hex Point CLtoCL
.312
.859
.861
0.000 Locating Shoulder
.812
.814
.688
M20x1.5-6H
.500 Minimum Full Thread
1.380
1.385
Maximum
.719 Port 2 Centerline
.730
.734
1.078
Maximum
.188 Port 3 Centerline
0.000
.156
1.125 Deep Socket
.687
.689
1.59
Minimum Depth of
.531 for Working
Parts Clearance
Port
1
Cartridge Nose
Support
.531
Maximum
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-021-001
994-021-101
TD-21A
Form Reamer
995-021-001
995-021-101
TR-21A
Metric Tap
998-998
998-998-101
M20x1.5-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
7/8” Hex Deep Socket:
Sun P/N: 998-100-001, Snap-On P/N: S281
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
253
US Selected Assemblies Catalogue #999-901-192
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 1
T-31A
4 Port Sun Cavity
1.250
Socket Wrench Clearance
(not included on Form Drill)
.859
.861
0.000
.562
Manifold
Edge
(not included on Form Drill)
.219 Maximum L.S.
Depth without Hex
Clearance
0.000 Locating Shoulder
.812
.814
.156
Minimum Clearance Distances:
.156 Minimum Hex
Extension
.438 Maximum L.S.
Depth without Socket
Clearance
1.000 Hex Clearance
1.125 Deep Socket
(.031 minimum below surface)
M20x1.5-6H
.500 Minimum Full Thread
.625
.730
.734
Maximum
Socket
Diameter
1.062 Hex Point CLto CL
.844 Port 4 Centerline
1.170
.562
.697
.699
Maximum
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-031-001
994-031-101
TD-31A
Form Reamer
995-031-001
995-031-101
TR-31A
Metric Tap
998-998
998-998-101
M20x1.5-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1.781 Port 3 Centerline
2.075
.562
.661
.663
Maximum
2.688 Port 2 Centerline
2.990
.625
.627
3.351
3.355
4.03
Minimum Depth
of .469 for
Working Parts
Clearance
Cartridge Nose
Support
7/8” Hex Deep Socket:
Port
1
.469
Max.
Sun P/N: 998-100-001, Snap-On P/N: S281
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
T-61A
6 Port Sun Cavity
1.250
Minimum Clearance Distances:
Socket Wrench Clearance
1.781 Minimum Hex
Extension
(not included on Form Drill)
1.000
1.438 Maximum L.S. Depth
without Socket Clearance
1.188 Minimum Surface
from L.S.
1.211
.671
.250
.889
.891
.625
Manifold
Edge
Maximum
.812 Port 6 Centerline
.312
.859
.861
Maximum
.188 Port 5 Centerline
0.000 Locating Shoulder
0.000
.812
.814
.156
M20x1.5-6H
.500 Minimum Full Thread
.730
.734
.625
Socket
Diameter
1.062 Hex Point CLto CL
Maximum
.844 Port 4 Centerline
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-061-001
994-061-101
TD-61A
Form Reamer
995-061-001
995-061-101
TR-61A
Metric Tap
998-998
998-998-101
M20x1.5-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1.170
.562
.697
.699
Maximum
1.781 Port 3 Centerline
2.075
.562
.661
.663
2.990
3.351
3.355
1.125 Deep Socket
Maximum
2.688 Port 2 Centerline
.625
.627
3.500
Minimum Depth of
.469 for Working
Parts Clearance
Port
1
.469
Max.
Cartridge Nose
Support
7/8” Hex Deep Socket:
Sun P/N: 998-100-001, Snap-On P/N: S281
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
US Selected Assemblies Catalogue #999-901-192
254
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 2
T-3A
2 Port Sun Cavity
1.500
Minimum Clearance Distances:
Socket Wrench Clearance
(not included on Form Drill)
.719
Manifold
Edge
.719 Minimum Hex
Extension
1.312
1.438 Deep Socket
.438 Maximum L.S.
Depth without Socket
Clearance
1.078
1.080
60 o
.172
Socket
Diameter
0.000 Locating Shoulder
0.000
(.031 minimum below surface)
1.031
1.033
.156
1.125
1”-14UNS-2B
.625 Minimum Full Thread
.933
.937
.969 Port 2 Centerline
o
45 Typical
(2) Places
1.547
.875
.877
Cartridge Nose
Support
+ .0025
1.885 _
2.25
Minimum Depth of
.688 for Working
Parts Clearance
Port
1
1.375 Hex Point CLto CL
Maximum
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-003-001
994-003-101
TD-3A
Form Reamer 995-003-001
995-003-101
TR-3A
UNS Tap
998-999
998-999-101
1”-14
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 1/8” Hex Deep Socket:
Sun P/N: 998-100-002, Snap-On P/N: S361
.688
Maximum
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
T-5A
2 Port Sun Cavity
Minimum Clearance Distances:
1.500
Socket Wrench Clearance
.719
Manifold
Edge
(not included on Form Drill)
.688 Minimum Hex
Extension
1.312
1.438 Deep Socket
.438 Maximum L.S.
Depth without Socket
Clearance
1.078
1.080
Socket
Diameter
1.172
0.000
.156
(.031 minimum below surface)
.875
Maximum
1”-14UNS-2B
.625 Minimum Full Thread
.844 Port 2 Centerline
.933
.937
1.297
1.635
(±.0025)
.875
.877
2.00
Minimum Depth of
.688 for Working
Parts Clearance
1.375 Hex Point CLto CL
0.000 Locating Shoulder
1.031
1.033
Port
1
Cartridge Nose
Support
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-005-001
994-005-101
TD-5A
Form Reamer
995-005-001
995-005-101
TR-5A
UNS Tap
998-999
998-999-101
1”-14
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 1/8” Hex Deep Socket:
.688
Maximum
Sun P/N: 998-100-002, Snap-On P/N: S361
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
255
US Selected Assemblies Catalogue #999-901-192
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 2
T-2A
3 Port Sun Cavity
1.500
Minimum Clearance Distances:
Socket Wrench Clearance
(not included on Form Drill)
.750
Manifold
Edge
o
45 Typical
(3) Places
1.375 Minimum Hex
Extension
1.438 Deep Socket
1.125 Maximum L.S.
Depth without Socket
Clearance
1.312
.804
.719 Minimum Surface
from L.S.
.375
1.078
1.080
0.000 Locating Shoulder
1.031
1.033
.625
1”-14UNS-2B
.625 Minimum Full Thread
Maximum
.719 Port 2 Centerline
.933
.937
1.047
1.375 Hex Point CLto CL
.219 Port 3 Centerline
0.000
.156
Socket
Diameter
Maximum
.875
.877
+ .0025
1.385 _
1.781
Minimum Depth of
.688 for Working
Parts Clearance
Cartridge Nose
Support
Port
1
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-002-001
994-002-101
TD-2A
Form Reamer 995-002-001
995-002-101
TR-2A
UNS Tap
998-999
998-999-101
1”-14
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 1/8” Hex Deep Socket:
.688
Maximum
Sun P/N: 998-100-002, Snap-On P/N: S361
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
T-22A
4 Port Sun Cavity
Minimum Clearance Distances:
1.500
Socket Wrench Clearance
(not included on Form Drill)
.766
Manifold
Edge
2.000 Minimum Hex
Extension
o
45 Typical
(4) Places
1.719 Maximum L.S.
Depth without Socket
Clearance
1.312
1.312 Minimum Surface
from L.S.
.312 Maximum
1.383
1.108
1.110
Socket
Diameter
.875 Port 4 Centerline
.688
0.000
1.438 Deep Socket
1.375 Hex Point CLto CL
.312
1.078
1.080
.219 Port 3 Centerline
1.031
1.033
0.000 Locating Shoulder
.156
.625
1”-14UNS-2B
.625 Minimum Full Thread
+ .0025
1.385 _
.875
.877
1.781
Minimum Depth of
.688 for Working
Parts Clearance
Maximum
.719 Port 2 Centerline
.933
.937
1.047
Maximum
Port
1
Cartridge Nose
Support
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-022-001
994-022-101
TD-22A
Form Reamer
995-022-001
995-022-101
TR-22A
UNS Tap
998-999
998-999-101
1”-14
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 1/8” Hex Deep Socket:
.688
Maximum
Sun P/N: 998-100-002, Snap-On P/N: S361
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
US Selected Assemblies Catalogue #999-901-192
256
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 2
T-32A
4 Port Sun Cavity
1.500
Socket Wrench Clearance
(not included on Form Drill)
1.078
1.080
0.000
.688 Minimum Hex
Extension
.438 Maximum L.S.
Depth without Socket
Clearance
1.312 Hex Clearance
Minimum Clearance Distances:
.720
Manifold
Edge
(not included on Form Drill)
.172 Maximum L.S.
Depth without Hex
Clearance
0.000 Locating Shoulder
1.031
1.033
1.438 Deep Socket
(.031 minimum below surface)
.156
.750
1”-14UNS-2B
.625 Minimum Full Thread
Maximum
Socket
Diameter
.953 Port 4 Centerline
.933
.937
1.375 Hex Point CLto CL
1.344
.562
.895
.897
Maximum
1.984 Port 3 Centerline
2.281
.562
.854
.856
Maximum
2.938 Port 2 Centerline
3.234
.812
.814
3.633
3.637
4.375
Minimum Depth of
.625 for Working
Parts Clearance
Port
1
.625
Maximum
Cartridge Nose
Support
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-032-001
994-032-101
TD-32A
Form Reamer 995-032-001
995-032-101
TR-32A
UNS Tap
998-999
998-999-101
1”-14UNS-2B
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 1/8” Hex Deep Socket:
Sun P/N: 998-100-002, Snap-On P/N: S361
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
T-62A
6 Port Sun Cavity
Minimum Clearance Distances:
1.500
Socket Wrench Clearance
(not included on Form Drill)
1.312
.688
.312
1.078
1.080
Maximum
1.031
1.033
.750
.895
.897
Maximum
1.984 Port 3 Centerline
2.281
.562
.854
.856
Maximum
2.938 Port 2 Centerline
.812
.814
3.75
Minimum Depth of
.625 for Working
Parts Clearance
Port
1
.625
Max.
1.375 Hex Point CLto CL
Maximum
.953 Port 4 Centerline
.562
3.633
3.637
Socket
Diameter
.219 Port 5 Centerline
0.000 Locating Shoulder
1”-14UNS-2B
.625 Minimum Full Thread
.933
.937
1.344
3.234
1.438 Deep Socket
.312 Maximum
.875 Port 6 Centerline
1.108
1.110
.156
.766
Manifold
Edge
1.312 Minimum Surface
from L.S.
1.281
0.000
2.000 Minimum Hex
Extension
1.719 Maximum L.S.
Depth without Socket
Clearance
Cartridge Nose
Support
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-062-001
994-062-101
TD-62A
Form Reamer
995-062-001
995-062-101
TR-62A
UNS Tap
998-999
998-999-101
1”-14UNS-2B
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 1/8” Hex Deep Socket:
Sun P/N: 998-100-002, Snap-On P/N: S361
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
257
US Selected Assemblies Catalogue #999-901-192
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 3
T-16A
2 Port Sun Cavity
.969 Minimum Hex
Extension
1.750
Minimum Clearance Distances:
Socket Wrench Clearance
(included on Form Drill)
1.031
Manifold
Edge
.234 ref
1.781 Deep Socket
1.562
1.564
0.000
0.000 Locating Shoulder
1.438
1.440
.188
Socket
Diameter
(.031 minimum below surface)
1.500
M36x2-6H
Maximum
1.781 Hex Point CLto CL
.688 Minimum Full Thread
1.343
1.347
1.312 Port 2 Centerline
o
45 Typical
(2) Places
2.062
1.250
1.252
+ .0025
2.448 _
2.84
Minimum Depth
of 1.000 for
Working Parts
Clearance
Cartridge Nose
Support
Port
1
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-016-001
994-016-101
TD-16A
Form Reamer
995-016-001
995-016-101
TR-16A
Metric Tap
998-996
998-996-101
M36x2-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 1/4” Hex Deep Socket:
1.000
Maximum
Sun P/N: 998-100-003, Snap-On P/N: S401
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
T-17A
3 Port Sun Cavity
1.812 Minimum Hex
Extension
1.750
Minimum Clearance Distances:
Socket Wrench Clearance
(included on Form Drill)
1.109
Manifold
Edge
o
45 Typical
(3) Places
1.875 Deep Socket
.969 ref
.906 Minimum Surface
from L.S.
.562 Maximum
.875
1.562
1.564
0.000
1.438
1.440
.875
M36x2-6H
Maximum
.688 Minimum Full Thread
1.000 Port 2 Centerline
1.343
1.347
1.438
1.250
1.252
2.234
Minimum Depth
of 1.000 for
Working Parts
Clearance
1.875 Hex Point CLto CL
0.000 Locating Shoulder
.188
+ .0025
1.822 _
Socket
Diameter
.312 Port 3 Centerline
Port
1
Cartridge Nose
Support
1 1/4” Hex Deep Socket:
Sun P/N: 998-100-003, Snap-On P/N: S401
1.000
Maximum
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
US Selected Assemblies Catalogue #999-901-192
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-017-001
994-017-101
TD-17A
Form Reamer
995-017-001
995-017-101
TR-17A
Metric Tap
998-996
998-996-101
M36x2-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
258
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 3
T-23A
4 Port Sun Cavity
2.469 Minimum Hex
Extension
1.750
Minimum Clearance Distances:
Socket Wrench Clearance
1.125
Manifold
Edge
(included on Form Drill)
o
45 Typical
(4) Places
1.938 Deep Socket
1.672 ref
1.625 Minimum Surface
from L.S.
1.594
.375
Maximum
1.592
1.594
1.125 Port 4 Centerline
1.562
1.564
.281 Port 3 Centerline
Socket
Diameter
.875
.500
0.000
0.000 Locating Shoulder
1.438
1.440
.188
M36x2-6H
.688 Minimum Full Thread
.875
1.343
1.347
1.438
+ .0025
1.822 _
Maximum
1.000 Port 2 Centerline
1.250
1.252
Cartridge Nose
Support
Port
1
2.234
Minimum Depth
of 1.000 for
Working Parts
Clearance
1.938 Hex Point CLto CL
Maximum
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-023-001
994-023-101
TD-23A
Form Reamer
995-023-001
995-023-101
TR-23A
Metric Tap
998-996
998-996-101
M36x2-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 1/4” Hex Deep Socket:
1.000
Maximum
Sun P/N: 998-100-003, Snap-On P/N: S401
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
T-33A
4 Port Sun Cavity
.688 Minimum Hex
Extension
1.750
Minimum Clearance Distances:
Socket Wrench Clearance
(not included on Form Drill)
0.000
.188
1.031
Manifold
Edge
.438 Maximum L.S.
Depth without Socket
Clearance
1.562
1.564
1.781 Deep Socket
0.000 Locating Shoulder
1.438
1.440
(.031 minimum below surface)
1.062
M36 x 2-6H
.688 Minimum Full Thread
1.343
1.347
Maximum
Socket
Diameter
1.188 Port 4 Centerline
1.781 Hex Point CLto CL
1.734
.719
1.296
1.298
Maximum
2.500 Port 3 Centerline
2.875
.719
1.250
1.252
Maximum
3.672 Port 2 Centerline
4.047
4.508
4.512
1.203
1.205
5.50
Minimum Depth of
.875 for Working
Parts Clearance
Port
1
Cartridge Nose
Support
.875
Maximum
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-033-001
994-033-101
TD-33A
Form Reamer
995-033-001
995-033-101
TR-33A
Metric Tap
998-996
998-996-101
M36x2-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 1/4” Hex Deep Socket:
Sun P/N: 998-100-003, Snap-On P/N: S401
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
259
US Selected Assemblies Catalogue #999-901-192
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 3
T-63A
1.750
6 Port Sun Cavity
Minimum Clearance Distances:
2.469 Minimum Hex
Extension
1.672 ref
1.625 Minimum Surface
from L.S.
.375 Maximum
Socket Wrench Clearance
(included on Form Drill)
1.594
1.592
1.594
1.125
Manifold
Edge
1.125 Port 6 Centerline
.875
.500
1.562
1.564
Maximum
.281 Port 5 Centerline
0.000 Locating Shoulder
0.000
1.438
1.440
M36 x 2-6H
.688 Minimum Full Thread
.188
1.062
1.188 Port 4 Centerline
1.734
.719
1.296
1.298
Maximum
2.500 Port 3 Centerline
2.875
.719
1.250
1.252
4.508
4.512
Maximum
3.672 Port 2 Centerline
1.203
1.205
4.750
Minimum Depth of
.875 for Working
Parts Clearance
Socket
Diameter
Maximum
1.938 Hex Point CLto CL
1.343
1.347
4.047
1.938 Deep Socket
Port
1
.875
Max.
Cartridge Nose
Support
1 1/4” Hex Deep Socket:
Sun P/N: 998-100-003, Snap-On P/N: S401
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
US Selected Assemblies Catalogue #999-901-192
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-063-001
994-063-101
TD-63A
Form Reamer 995-063-001
995-063-101
TR-63A
Metric Tap
998-996
998-996-101
M36x2-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
260
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 4
T-18A
2 Port Sun Cavity
1.188 Minimum Hex
Extension
2.312
Minimum Clearance Distances:
Socket Wrench Clearance
1.375
Manifold
Edge
(included on Form Drill)
.297 ref
2.281 Deep Socket
2.062
2.064
0.000
1.912
1.914
0.000 Locating Shoulder
Socket
Diameter
(.031 minimum below surface)
.219
M48x2-6H
1.875
2.281 Hex Point CLto CL
Maximum
.875 Minimum Full Thread
1.813
1.817
1.688 Port 2 Centerline
o
45 Typical
(2) Places
2.594
1.625
1.627
Cartridge Nose
Support
+ .0025
3.135 _
3.59
Minimum Depth
of 1.250 for
Working Parts
Clearance
Port
1
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-018-001
994-018-101
TD-18A
Form Reamer 995-018-001
995-018-101
TR-18A
Metric Tap
998-992
998-992-101
M48x2-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 5/8” Hex Deep Socket:
1.250
Maximum
Sun P/N: 998-100-004, Snap-On P/N: LS522
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
T-19A
3 Port Sun Cavity
Minimum Clearance Distances:
2.312 Minimum Hex
Extension
2.312
Socket Wrench Clearance
1.500
Manifold
Edge
(not included on Form Drill)
o
45 Typical
(3) Places
1.250 ref
1.156 Minimum Surface
from L.S.
1.125
.750
0.000
.219
Maximum
2.062
2.064
.438 Port 3 Centerline
1.912
1.914
0.000 Locating Shoulder
M48x2-6H
1.250
Maximum
.875 Minimum Full Thread
1.969
1.375 Port 2 Centerline
1.813
1.817
1.625
1.627
+ .0025
2.510 _
2.98
Minimum Depth
of 1.250 for
Working Parts
Clearance
2.469 Deep Socket
Port
1
Cartridge Nose
Support
Socket
Diameter
2.469 Hex Point CLto CL
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-019-001
994-019-101
TD-19A
Form Reamer
995-019-001
995-019-101
TR-19A
Metric Tap
998-992
998-992-101
M48x2-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 5/8” Hex Deep Socket:
1.250
Maximum
Sun P/N: 998-100-004, Snap-On P/N: LS522
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
261
US Selected Assemblies Catalogue #999-901-192
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 4
T-24A
4 Port Sun Cavity
3.125 Minimum Hex
Extension
2.312
Minimum Clearance Distances:
Socket Wrench Clearance
(included on Form Drill)
o
45 Typical
(4) Places
2.078 ref
2.000 Minimum Surface
from L.S.
.500 Maximum
1.969
2.092
2.094
1.125
2.062
2.064
Socket
Diameter
Maximum
2.531 Hex Point CLto CL
.406 Port 3 Centerline
0.000
0.000 Locating Shoulder
1.912
1.914
M48x2-6H
1.25
Maximum
.875 Minimum Full Thread
1.813
1.817
1.375 Port 2 Centerline
1.969
+ .0025
2.510 _
2.531 Deep Socket
1.438 Port 4 Centerline
.688
.219
1.531
Manifold
Edge
1.625
1.627
Cartridge Nose
Support
Port
1
2.984
Minimum Depth
of 1.250 for
Working Parts
Clearance
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-024-001
994-024-101
TD-24A
Form Reamer 995-024-001
995-024-101
TR-24A
Metric Tap
998-992
998-992-101
M48x2-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 5/8” Hex Deep Socket:
1.250
Maximum
Sun P/N: 998-100-004, Snap-On P/N: LS522
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
T-34A
4 Port Sun Cavity
Minimum Clearance Distances:
1.188 Minimum Hex
Extension
0.000
2.312
Socket Wrench Clearance
(not included on Form Drill)
.438 Maximum L.S.
Depth without Socket
Clearance
0.000 Locating Shoulder
2.062
2.063
1.912
1.914
M48x2-6H
.875 Minimum Full Thread
1.375
Manifold
Edge
(.031 minimum below surface)
1.250
1.813
1.817
Maximum
Socket
Diameter
1.375 Port 4 Centerline
2.281 Hex Point CLto CL
2.016
1.000
1.766
1.768
Maximum
3.000 Port 3 Centerline
3.516
1.000
1.719
1.721
Maximum
4.500 Port 2 Centerline
5.016
5.508
5.512
1.672
1.674
6.56
Minimum Depth
of 1.312 for
Working Parts
Clearance
2.281 Deep Socket
Cartridge Nose
Support
1 5/8” Hex Deep Socket:
Port
1
1.312
Maximum
Sun P/N: 998-100-004, Snap-On P/N: LS522
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
US Selected Assemblies Catalogue #999-901-192
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-034-001
994-034-101
TD-34A
Form Reamer
995-034-001
995-034-101
TR-34A
Metric Tap
998-992
998-992-101
M48x2-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
262
General Information: Cartridge Cavities and Cavity Tools
NOTES: Thin wall deep hex sockets, preferred for installing Sun cartridges, are available from Sun or Snap-On Tools Corporation.
Complete cavity machining dimensions are provided with form tools or supplied upon request.
Dimensions shown below are simplified for manifold design purposes.
SERIES 4
T-64A
2.312
6 Port Sun Cavity
3.125 Minimum Hex
Extension
Socket Wrench Clearance
(included on Form Drill)
2.078 Maximum L.S.
Depth without Socket
Clearance
2.000
.500 Maximum
1.969
1.125
Minimum Clearance Distances:
2.092
2.094
1.53
Manifold
Edge
1.438 Port 6 Centerline
.688
2.062
2.064
2.531 Deep Socket
Maximum
.406 Port 5 Centerline
0.000
0.000 Locating Shoulder
1.912
1.914
.219
M48x2-6H
.875 Minimum Full Thread
1.813
1.817
1.250
Socket
Diameter
Maximum
2.531 Hex Point CLto CL
1.375 Port 4 Centerline
2.016
1.000
1.766
1.768
3.000 Port 3 Centerline
3.516
1.000
1.719
1.721
5.016
5.508
5.512
Maximum
4.500 Port 2 Centerline
1.672
1.674
5.75
Minimum Depth
of 1.312 for
Working Parts
Clearance
Maximum
Cartridge Nose
Support
Port
1
1.312
Max.
High Speed Steel
Titanium Coated
Description
Model Code
Model Code
Form Drill
994-064-001
994-064-101
TD-64A
Form Reamer 995-064-001
995-064-101
TR-64A
Metric Tap
998-992
998-992-101
M48x2-6H
Note: Drill and Reamer have a #3 Morse taper. Tap has straight shank.
1 5/8” Hex Deep Socket:
Sun P/N: 999-100-004, Snap-On P/N: LS522
Cavity Diameters to be concentric to threads within .002.
© SUN Hydraulics Corporation
263
US Selected Assemblies Catalogue #999-901-192
Model Code Index
CARTRIDGES
Model Code
Cavity
Page
Model Code
Cavity
Page
Model Code
Cavity
Page
CBCA - ✱✱✱
T-11A
50
CWIA - ✱✱✱
T-24A
70
PBJB - ✱✱✱
T-19A
34
CBCB - ✱✱✱
T-11A
50
CWIG - ✱✱✱
T-24A
70
PPDB - ✱✱✱
T-11A
42
CBCG - ✱✱✱
T-11A
50
CWIK - ✱✱✱
T-24A
70
PPFB - ✱✱✱
T-2A
42
CBCH - ✱✱✱
T-11A
50
CWIL - ✱✱✱
T-24A
70
PPHB - ✱✱✱
T-17A
42
CBCL - ✱✱✱
T-11A
50
CXAD - ✱✱✱
T-162A
102
PPJB - ✱✱✱
T-19A
42
CBCY - ✱✱✱
T-11A
50
CXBA - ✱✱✱
T-162A
102
PRDB - ✱✱✱
T-11A
42
CBEA - ✱✱✱
T-2A
50
CXCD - ✱✱✱
T-13A
102
PRFB - ✱✱✱
T-2A
42
CBEB - ✱✱✱
T-2A
50
CXDA - ✱✱✱
T-13A
102
PRHB - ✱✱✱
T-17A
42
CBEG - ✱✱✱
T-2A
50
CXED - ✱✱✱
T-5A
102
PRJB - ✱✱✱
T-19A
42
CBEH - ✱✱✱
T-2A
50
CXFA - ✱✱✱
T-5A
102
RDBA - ✱✱✱
T-162A
2
CBEL - ✱✱✱
T-2A
50
CXGD - ✱✱✱
T-16A
102
RDDA - ✱✱✱
T-10A
2
CBEY - ✱✱✱
T-2A
50
CXHA - ✱✱✱
T-16A
102
RDFA - ✱✱✱
T-3A
2
CBGA - ✱✱✱
T-17A
50
CXID - ✱✱✱
T-18A
102
RDHA - ✱✱✱
T-16A
2
CBGB - ✱✱✱
T-17A
50
CXJA - ✱✱✱
T-18A
102
RDJA - ✱✱✱
T-18A
2
CBGG - ✱✱✱
T-17A
50
FCBB - ✱✱✱
T-162A
118
RPCC - ✱✱✱
T-162A
2
CBGH - ✱✱✱
T-17A
50
FCCB - ✱✱✱
T-13A
118
RPEC - ✱✱✱
T-10A
2
CBGL - ✱✱✱
T-17A
50
FCDB - ✱✱✱
T-5A
118
RPGC - ✱✱✱
T-3A
2
CBGY - ✱✱✱
T-17A
50
FCEB - ✱✱✱
T-16A
118
RPIC - ✱✱✱
T-16A
2
CBIA - ✱✱✱
T-19A
50
FCFB - ✱✱✱
T-18A
118
RPKC - ✱✱✱
T-18A
2
CBIB - ✱✱✱
T-19A
50
FDBA - ✱✱✱
T-13A
126
RSBC - ✱✱✱
T-163A
20
CBIG - ✱✱✱
T-19A
50
FDCB - ✱✱✱
T-5A
126
RSDC - ✱✱✱
T-11A
20
CBIH - ✱✱✱
T-19A
50
FDEA - ✱✱✱
T-16A
126
RSFC - ✱✱✱
T-2A
20
CBIL - ✱✱✱
T-19A
50
FDFA - ✱✱✱
T-18A
126
RSHC - ✱✱✱
T-17A
20
CBIY - ✱✱✱
T-19A
50
FRBA - ✱✱✱
T-163A
134
RSJC - ✱✱✱
T-19A
20
CKBB - ✱✱✱
T-163A
78
FRCA - ✱✱✱
T-11A
134
RVBA - ✱✱✱
T-163A
12
CKBD - ✱✱✱
T-163A
78
FRDA - ✱✱✱
T-2A
134
RVCA - ✱✱✱
T-11A
12
CKCB - ✱✱✱
T-11A
78
FREA - ✱✱✱
T-17A
134
RVEA - ✱✱✱
T-2A
12
CKCD - ✱✱✱
T-11A
78
FRFA - ✱✱✱
T-19A
134
RVGA - ✱✱✱
T-17A
12
CKEB - ✱✱✱
T-2A
78
FXBA - ✱✱✱
T-162A
118
RVIA - ✱✱✱
T-19A
12
CKED - ✱✱✱
T-2A
78
FXCA - ✱✱✱
T-13A
118
SCCA - ✱✱✱
T-11A
28
CKGB - ✱✱✱
T-17A
78
FXDA - ✱✱✱
T-5A
118
SCEA - ✱✱✱
T-2A
28
CKGD - ✱✱✱
T-17A
78
FXEA - ✱✱✱
T-16A
118
SCGA - ✱✱✱
T-17A
28
CKIB - ✱✱✱
T-19A
78
FXFA - ✱✱✱
T-18A
118
SCIA - ✱✱✱
T-19A
28
CKID - ✱✱✱
T-19A
78
NCBB - ✱✱✱
T-162A
110
SXCA - ✱✱✱
T-11A
20
CVCV - ✱✱✱
T-21A
94
NCCB - ✱✱✱
T-13A
110
SXEA - ✱✱✱
T-2A
20
CVEV - ✱✱✱
T-22A
94
NCCC - ✱✱✱
T-13A
110
CVGV - ✱✱✱
T-23A
94
NCEB - ✱✱✱
T-5A
110
CVIV - ✱✱✱
T-24A
94
NCEC - ✱✱✱
T-5A
110
CWCA- ✱✱✱
T-21A
70
NCFB - ✱✱✱
T-16A
110
CWCG- ✱✱✱
T-21A
70
NCGB - ✱✱✱
T-18A
110
CWCK- ✱✱✱
T-21A
70
NCGC - ✱✱✱
T-18A
110
CWCL - ✱✱✱
T-21A
70
NFBC - ✱✱✱
T-162A
110
CWEA - ✱✱✱
T-22A
70
NFCC - ✱✱✱
T-13A
110
CWEG- ✱✱✱
T-22A
70
NFDC - ✱✱✱
T-5A
110
CWEK - ✱✱✱
T-22A
70
NFEC - ✱✱✱
T-16A
110
CWEL - ✱✱✱
T-22A
70
NFFC - ✱✱✱
T-18A
110
CWGA- ✱✱✱
T-23A
70
PBBB - ✱✱✱
T-163A
34
CWGG- ✱✱✱
T-23A
70
PBDB - ✱✱✱
T-11A
34
CWGK- ✱✱✱
T-23A
70
PBFB - ✱✱✱
T-2A
34
CWGL - ✱✱✱
T-23A
70
PBHB - ✱✱✱
T-17A
34
US Selected Assemblies Catalogue #999-901-192
264
Model Code Index
ASSEMBLIES
Model Code
Cavity
Page
Model Code
Cavity
Page
Cavity
Page
CBE*-L*N-EMB
T-11A
205
CBC*-LHN-XVH
T-11A
60
CBCA-LAN-WZE
T-11A
238
CBE*-L*N-EMC
T-11A
205
CBC*-LHN-XVI
T-11A
60
CBCA-LAN-WZH
T-11A
238
CBE*-L*N-EMJ
T-11A
205
CBC*-LHN-YEB
T-11A
58
CBCA-LAN-WZL
T-11A
239
CBE*-L*N-EMK
T-11A
205
CBC*-LHN-YEC
T-11A
58
CBCA-LAN-WZP
T-11A
239
CBE*-L*N-ENB
T-11A
207
CBC*-LHN-YEI
T-11A
58
CBCA-LAN-WZS
T-11A
239
CBE*-L*N-ENC
T-11A
207
CBC*-LHN-YEJ
T-11A
58
CBCA-LAN-WZV
T-11A
239
CBE*-L*N-ENJ
T-11A
207
CBC*-LHN-YEK
T-11A
58
CBCA-LAN-XTS
T-11A
231
CBE*-L*N-ENK
T-11A
207
CBC*-LHN-YGB
T-11A
61
CBCA-LAN-YTA
T-11A
231
CBE*-L*N-EPB
T-11A
209
CBC*-LHN-YGC
T-11A
61
CBCA-LAN-ZDV
T-11A
231
CBE*-L*N-EPC
T-11A
209
CBC*-LHN-YGI
T-11A
61
CBCA-LAN-ZDY
T-11A
231
CBE*-L*N-EPJ
T-11A
209
CBC*-LHN-YGJ
T-11A
61
CBCA-LAN-ZPD
T-11A
230
CBE*-L*N-EPK
T-11A
209
CBC*-LHN-YGK
T-11A
61
CBCA-LAN-ZPD
T-11A
230
CBE*-L*N-EQB
T-11A
211
CBC*-LHN-YVM
T-11A
67
CBE*-L*N-BMC
T-2A
205
CBE*-L*N-EQC
T-11A
211
CBC*-LHN-YVY
T-11A
67
CBE*-L*N-BMD
T-2A
205
CBE*-L*N-EQJ
T-11A
211
CBC*-LHN-ZTC
T-11A
66
CBE*-L*N-BMK
T-2A
205
CBE*-L*N-EQK
T-11A
211
CBC*-LHN-ZTN
T-11A
66
CBE*-L*N-BML
T-2A
205
CBG*-L*N-HME
T-17A
206
CBC*-LJN-EBA
T-11A / T-21A
151
CBE*-L*N-BNC
T-2A
207
CBG*-L*N-HMF
T-17A
206
CBC*-LJN-EBY
T-11A / T-21A
151
CBE*-L*N-BND
T-2A
207
CBG*-L*N-HMM
T-17A
206
CBC*-LJN-ECB
T-11A
52
CBE*-L*N-BNK
T-2A
207
CBG*-L*N-HMN
T-17A
206
CBC*-LJN-ECC
T-11A
52
CBE*-L*N-BNL
T-2A
207
CBG*-L*N-HNE
T-17A
208
CBC*-LJN-ECH
T-11A
52
CBE*-L*N-BPC
T-2A
209
CBG*-L*N-HNF
T-17A
208
CBC*-LJN-ECI
T-11A
52
CBE*-L*N-BPD
T-2A
209
CBG*-L*N-HNM
T-17A
208
CBC*-LJN-ECJ
T-11A
52
CBE*-L*N-BPK
T-2A
209
CBG*-L*N-HNN
T-17A
208
CBC*-LJN-EGB
T-11A
56
CBE*-L*N-BPL
T-2A
209
CBG*-L*N-HPE
T-17A
210
CBC*-LJN-EGC
T-11A
56
CBE*-L*N-BQC
T-2A
211
CBG*-L*N-HPF
T-17A
210
CBC*-LJN-EGI
T-11A
56
CBE*-L*N-BQD
T-2A
211
CBG*-L*N-HPM
T-17A
210
CBC*-LJN-EGJ
T-11A
56
CBE*-L*N-BQK
T-2A
211
CBG*-L*N-HPN
T-17A
210
CBC*-LJN-EGK
T-11A
56
CBE*-L*N-BQL
T-2A
211
CBG*-L*N-HQE
T-17A
212
CBC*-LJN-EJB
T-11A
55
CBE*-LHN-BB8
T-2A
167
CBG*-L*N-HQF
T-17A
212
CBC*-LJN-EJI
T-11A
55
CBE*-LHN-BBA
T-2A
167
CBG*-L*N-HQM
T-17A
212
CBC*-LJN-EJJ
T-11A
55
CBE*-LHN-BBB
T-2A
167
CBG*-L*N-HQN
T-17A
212
CBC*-LJN-XGB
T-11A
63
CBE*-LHN-BBY
T-2A
167
CBC*-LHN-EBA
T-11A
151
CBC*-LJN-XGI
T-11A
63
CBE*-LHN-BCC
T-2A
52
CBC*-LHN-EBY
T-11A
151
CBC*-LJN-XGJ
T-11A
63
CBE*-LHN-BCD
T-2A
52
CBC*-LHN-ECB
T-11A
52
CBC*LJN-XVG
T-11A
60
CBE*-LHN-BCI
T-2A
52
CBC*-LHN-ECC
T-11A
52
CBC*LJN-XVH
T-11A
60
CBE*-LHN-BCJ
T-2A
52
CBC*-LHN-ECH
T-11A
52
CBC*LJN-XVI
T-11A
60
CBE*-LHN-BGC
T-2A
56
CBC*-LHN-ECI
T-11A
52
CBC*-LJN-YEB
T-11A
58
CBE*-LHN-BGD
T-2A
56
CBC*-LHN-ECJ
T-11A
52
CBC*-LJN-YEC
T-11A
58
CBE*-LHN-BGI
T-2A
56
CBC*-LHN-EGB
T-11A
56
CBC*-LJN-YEI
T-11A
58
CBE*-LHN-BGJ
T-2A
56
CBC*-LHN-EGC
T-11A
56
CBC*-LJN-YEJ
T-11A
58
CBE*-LHN-BJ8
T-2A
178
CBC*-LHN-EGI
T-11A
56
CBC*-LJN-YEK
T-11A
58
CBE*-LHN-BJA
T-2A
178
CBC*-LHN-EGJ
T-11A
56
CBC*-LJN-YGB
T-11A
61
CBE*-LHN-BJB
T-2A
178
CBC*-LHN-EGK
T-11A
56
CBC*-LJN-YGC
T-11A
61
CBE*-LHN-BJY
T-2A
178
CBC*-LHN-EJB
T-11A
55
CBC*-LJN-YGI
T-11A
61
CBE*-LHN-BVC
T-2A
55
CBC*-LHN-EJI
T-11A
55
CBC*-LJN-YGJ
T-11A
61
CBE*-LHN-BVD
T-2A
55
CBC*-LHN-EJJ
T-11A
55
CBC*-LJN-YGK
T-11A
61
CBE*-LHN-BVI
T-2A
55
CBC*-LHN-XGB
T-11A
63
CBC*-LJN-YVM
T-11A
67
CBE*-LHN-BVJ
T-2A
55
CBC*-LHN-XGI
T-11A
63
CBC*-LJN-YVY
T-11A
67
CBE*-LHN-XAC
T-2A
60
CBC*-LHN-XGJ
T-11A
63
CBC*-LJN-ZTC
T-11A
66
CBE*-LHN-XAD
T-2A
60
CBC*-LHN-XVG
T-11A
60
CBC*-LJN-ZTN
T-11A
66
CBE*-LHN-XHC
T-2A
63
265
Model Code
US Selected Assemblies Catalogue #999-901-192
Model Code Index
ASSEMBLIES
Model Code
Cavity
Page
Model Code
Cavity
Page
Model Code
Cavity
Page
CBE*-LHN-XHD
T-2A
63
CBE*-LJN-YHC
T-2A
61
CBG*-LHN-ZDR
T-17A
65
CBE*-LHN-XKD
T-17A
63
CBE*-LJN-YHD
T-2A
61
CBG*-LHN-ZNW
T-17A
64
CBE*-LHN-XKE
T-17A
63
CBE*-LJN-YHK
T-2A
61
CBG*-LHN-ZNX
T-19A
64
CBE*-LHN-XZQ
T-19A
63
CBE*-LJN-YHL
T-2A
61
CBG*-LHN-ZTJ
T-17A
66
CBE*-LHN-YAB
T-2A
58
CBE*-LJN-YVV
T-2A
67
CBG*-LHN-ZTK
T-17A
66
CBE*-LHN-YAC
T-2A
58
CBE*-LJN-YVW
T-2A
67
CBG*-LJN-BKA
T-17A
188
CBE*-LHN-YAD
T-2A
58
CBE*-LJN-ZDS
T-2A
65
CBG*-LJN-BKB
T-17A
188
CBE*-LHN-YAI
T-2A
58
CBE*-LJN-ZNV
T-2A
64
CBG*-LJN-BKY
T-17A
188
CBE*-LHN-YAJ
T-2A
58
CBE*-LJN-ZTF
T-2A
66
CBG*-LJN-HCE
T-17A
53
CBE*-LHN-YHC
T-2A
61
CBE*-LJN-ZTG
T-2A
66
CBG*-LJN-HCF
T-17A
53
CBE*-LHN-YHD
T-2A
61
CBEA-LAN-VWZ
T-2A
235
CBG*-LJN-HCL
T-17A
53
CBE*-LHN-YHK
T-2A
61
CBEA-LAN-VZX/M
T-2A
235
CBG*-LJN-HCM
T-17A
53
CBE*-LHN-YHL
T-2A
61
CBEA-LAN-WKH
T-2A
241
CBG*-LJN-HDD
T-17A
55
CBE*-LHN-YVV
T-2A
67
CBEA-LAN-WKL
T-2A
241
CBG*-LJN-HDE
T-17A
55
CBE*-LHN-YVW
T-2A
67
CBEA-LAN-WKP
T-2A
242
CBG*-LJN-HDE
T-17A
56
CBE*-LHN-ZDS
T-2A
65
CBEA-LAN-WKS
T-2A
242
CBG*-LJN-HDF
T-17A
56
CBE*-LHN-ZNV
T-2A
64
CBEA-LAN-WKV
T-2A
242
CBG*-LJN-HDL
T-17A
55
CBE*-LHN-ZTF
T-2A
66
CBEA-LAN-WKY
T-2A
242
CBG*-LJN-HDL
T-17A
56
CBE*-LHN-ZTG
T-2A
66
CBEA-LAN-XYS
T-2A
234
CBG*-LJN-HDM
T-17A
55
CBE*-LJN-BB8
T-2A
167
CBEA-LAN-YTC
T-2A
234
CBG*-LJN-HDM
T-17A
56
CBE*-LJN-BBA
T-2A
167
CBEA-LAN-ZPG
T-2A
233
CBG*-LJN-YJE
T-17A
59
CBE*-LJN-BBB
T-2A
167
CBEA-LAN-ZPI
T-2A
233
CBG*-LJN-YJF
T-17A
59
CBE*-LJN-BBY
T-2A
167
CBEA-LAN-ZPM
T-2A
233
CBG*-LJN-YJL
T-17A
59
CBE*-LJN-BCC
T-2A
52
CBEA-LAN-ZPO
T-2A
234
CBG*-LJN-YJM
T-17A
59
CBE*-LJN-BCD
T-2A
52
CBG*-LHN-BKA
T-17A
188
CBG*-LJN-YKE
T-17A
61
CBE*-LJN-BCI
T-2A
52
CBG*-LHN-BKB
T-17A
188
CBG*-LJN-YKF
T-17A
61
CBE*-LJN-BCJ
T-2A
52
CBG*-LHN-BKY
T-17A
188
CBG*-LJN-YKL
T-17A
61
CBE*-LJN-BGC
T-2A
56
CBG*-LHN-HCE
T-17A
53
CBG*-LJN-YKM
T-17A
61
CBE*-LJN-BGD
T-2A
56
CBG*-LHN-HCF
T-17A
53
CBG*-LJN-YVS
T-17A
67
CBE*-LJN-BGI
T-2A
56
CBG*-LHN-HCL
T-17A
53
CBG*-LJN-YVT
T-17A
67
CBE*-LJN-BGJ
T-2A
56
CBG*-LHN-HCM
T-17A
53
CBG*-LJN-ZDR
T-17A
65
CBE*-LJN-BJ8
T-2A
178
CBG*-LHN-HDD
T-17A
55
CBG*-LJN-ZNW
T-17A
64
CBE*-LJN-BJA
T-2A
178
CBG*-LHN-HDE
T-17A
55
CBG*-LJN-ZNX
T-19A
64
CBE*-LJN-BJB
T-2A
178
CBG*-LHN-HDE
T-17A
56
CBG*-LJN-ZTJ
T-17A
66
CBE*-LJN-BJY
T-2A
178
CBG*-LHN-HDF
T-17A
56
CBG*-LJN-ZTK
T-17A
66
CBE*-LJN-BVC
T-2A
55
CBG*-LHN-HDL
T-17A
55
CBI*-LHN-HBA
T-19A
198
CBE*-LJN-BVD
T-2A
55
CBG*-LHN-HDL
T-17A
56
CBI*-LHN-HBB
T-19A
198
CBE*-LJN-BVI
T-2A
55
CBG*-LHN-HDM
T-17A
55
CBI*-LHN-HBY
T-19A
198
CBE*-LJN-BVJ
T-2A
55
CBG*-LHN-HDM
T-17A
56
CBI*-LHN-KCE
T-19A
53
CBE*-LJN-XAC
T-2A
60
CBG*-LHN-XJW
T-17A
60
CBI*-LHN-KCF
T-19A
53
CBE*-LJN-XAD
T-2A
60
CBG*-LHN-XJX
T-17A
60
CBI*-LHN-KCM
T-19A
53
CBE*-LJN-XHC
T-2A
63
CBG*-LHN-YJE
T-17A
59
CBI*-LHN-KCN
T-19A
53
CBE*-LJN-XHD
T-2A
63
CBG*-LHN-YJF
T-17A
59
CBI*-LHN-KG6
T-19A
57
CBE*-LJN-XKD
T-17A
63
CBG*-LHN-YJL
T-17A
59
CBI*-LHN-KGR
T-19A
57
CBE*-LJN-XKE
T-17A
63
CBG*-LHN-YJM
T-17A
59
CBI*-LHN-XZZ
T-11A
54
CBE*-LJN-XZQ
T-19A
63
CBG*LHN-YKE
T-17A
61
CBI*-LHN-YM6
T-19A
59
CBE*-LJN-YAB
T-2A
58
CBG*LHN-YKF
T-17A
61
CBI*-LHN-YMR
T-19A
59
CBE*-LJN-YAC
T-2A
58
CBG*LHN-YKL
T-17A
61
CBI*-LHN-YN6
T-19A
62
CBE*-LJN-YAD
T-2A
58
CBG*LHN-YKM
T-17A
61
CBI*-LHN-YNR
T-19A
62
CBE*-LJN-YAI
T-2A
58
CBG*-LHN-YVS
T-17A
67
CBI*-LHN-Z8Z
T-19A
54
CBE*-LJN-YAJ
T-2A
58
CBG*-LHN-YVT
T-17A
67
CBI*-LHN-ZFD
T-19A
65
US Selected Assemblies Catalogue #999-901-192
266
Model Code Index
ASSEMBLIES
Model Code
Cavity
Page
Model Code
Cavity
Page
Model Code
Cavity
Page
CBI*-LJN-HBA
T-19A
198
CKEB-XCN-BBA
T-2A
168
CKIB-XCN-HBY
T-19A
199
CBI*-LJN-HBB
T-19A
198
CKEB-XCN-BBB
T-2A
168
CKIB-XCN-KCE
T-19A
81
CBI*-LJN-HBY
T-19A
198
CKEB-XCN-BBY
T-2A
168
CKIB-XCN-KCF
T-19A
81
CBI*-LJN-KCE
T-19A
53
CKEB-XCN-BCC
T-2A
80
CKIB-XCN-KCM
T-19A
81
CBI*-LJN-KCF
T-19A
53
CKEB-XCN-BCD
T-2A
80
CKIB-XCN-KCN
T-19A
81
CBI*-LJN-KCM
T-19A
53
CKEB-XCN-BCI
T-2A
80
CKIB-XCN-XZZ
T-19A
84
CBI*-LJN-KCN
T-19A
53
CKEB-XCN-BCJ
T-2A
80
CKIB-XCN-YM6
T-19A
87
CBI*-LJN-KG6
T-19A
57
CKEB-XCN-BJA
T-2A
179
CKIB-XCN-Z8Z
T-19A
84
CBI*-LJN-KGR
T-19A
57
CKEB-XCN-BJB
T-2A
179
CKIB-XCN-ZFD
T-19A
90
CBI*-LJN-XZZ
T-11A
54
CKEB-XCN-BJY
T-2A
179
CKIB-XCN-ZNX
T-19A
89
CBI*-LJN-YM6
T-19A
59
CKEB-XCN-BVC
T-2A
83
CSAA-BXN-DKS
T-13A
192
CBI*-LJN-YMR
T-19A
59
CKEB-XCN-BVD
T-2A
83
CSAA-BXN-GBS
T-13A
158
CBI*-LJN-YN6
T-19A
62
CKEB-XCN-BVI
T-2A
83
CSAA-BXN-IBS
T-13A
202
CBI*-LJN-YNR
T-19A
62
CKEB-XCN-BVJ
T-2A
83
CSAA-BXN-WZY
T-11A
239
CBI*-LJN-Z8Z
T-19A
54
CKEB-XCN-XAC
T-2A
88
CVCV-XCN-MAA
T-21A
96
CBI*-LJN-ZFD
T-19A
65
CKEB-XCN-XAD
T-2A
88
CVCV-XCN-MAB
T-21A
96
CBIA-LHN-XZP
T-19A
60
CKEB-XCN-XAI
T-2A
88
CVCV-XCN-MAC
T-21A
96
CKBB-XCN-JCA
T-163A
80
CKEB-XCN-XAJ
T-2A
88
CVCV-XCN-MAI
T-21A
96
CKBB-XCN-JCB
T-163A
80
CKEB-XCN-YAC
T-2A
86
CVCV-XCN-MAJ
T-21A
96
CKBB-XCN-JCH
T-163A
80
CKEB-XCN-YAD
T-2A
86
CVCV-XCN-MAK
T-21A
96
CKBB-XCN-JCI
T-163A
80
CKEB-XCN-YAJ
T-2A
86
CVCV-XCN-MBA
T-21A
152
CKBB-XCN-JJA
T-163A
82
CKEB-XCN-YAK
T-2A
86
CVCV-XCN-MBB
T-21A
152
CKBB-XCN-JJB
T-163A
82
CKEB-XCN-YVV
T-2A
92
CVCV-XCN-MBY
T-21A
152
CKBB-XCN-JJH
T-163A
82
CKEB-XCN-YVW
T-2A
92
CVCV-XCN-XPA
T-21A
99
CKBB-XCN-JJI
T-163A
82
CKEB-XCN-ZDS
T-2A
90
CVCV-XCN-XPB
T-21A
99
CKBB-XCN-JYA
T-163A
85
CKEB-XCN-ZNV
T-2A
89
CVCV-XCN-XPC
T-21A
99
CKBB-XCN-JYB
T-163A
85
CKEB-XCN-ZNW
T-17A
89
CVCV-XCN-XPI
T-21A
99
CKBB-XCN-JYH
T-163A
85
CKEB-XCN-ZTF
T-2A
91
CVCV-XCN-XPJ
T-21A
99
CKBB-XCN-JYI
T-163A
85
CKEB-XCN-ZTG
T-2A
91
CVCV-XCN-XPK
T-21A
99
CKCB-XCN-EBA
T-11A
152
CKGB-XCN-BKA
T-17A
189
CVEV-XCN-NAB
T-22A
96
CKCB-XCN-EBY
T-11A
152
CKGB-XCN-BKB
T-17A
189
CVEV-XCN-NAC
T-22A
96
CKCB-XCN-ECB
T-11A
80
CKGB-XCN-BKY
T-17A
189
CVEV-XCN-NAD
T-22A
96
CKCB-XCN-ECC
T-11A
80
CKGB-XCN-HCE
T-17A
81
CVEV-XCN-NAJ
T-22A
96
CKCB-XCN-ECH
T-11A
80
CKGB-XCN-HCF
T-17A
81
CVEV-XCN-NAK
T-22A
96
CKCB-XCN-ECI
T-11A
80
CKGB-XCN-HCL
T-17A
81
CVEV-XCN-XIB
T-22A
99
CKCB-XCN-ECJ
T-11A
80
CKGB-XCN-HCM
T-17A
81
CVEV-XCN-XIC
T-22A
99
CKCB-XCN-EJB
T-11A
82
CKGB-XCN-HDD
T-17A
83
CVEV-XCN-XID
T-22A
99
CKCB-XCN-EJI
T-11A
82
CKGB-XCN-HDE
T-17A
83
CVEV-XCN-XII
T-22A
99
CKCB-XCN-EJJ
T-11A
82
CKGB-XCN-HDL
T-17A
83
CVEV-XCN-XIJ
T-22A
99
CKCB-XCN-XEB
T-11A
88
CKGB-XCN-HDM
T-17A
83
CVGV-XCN-PCD
T-23A
97
CKCB-XCN-XEI
T-11A
88
CKGB-XCN-YJE
T-17A
87
CVGV-XCN-PCE
T-23A
97
CKCB-XCN-XEJ
T-11A
88
CKGB-XCN-YJF
T-17A
87
CVGV-XCN-PCF
T-23A
97
CKCB-XCN-YEB
T-11A
85
CKGB-XCN-YJL
T-17A
87
CVGV-XCN-PCL
T-23A
97
CKCB-XCN-YEC
T-11A
85
CKGB-XCN-YJM
T-17A
87
CVGV-XCN-PCM
T-23A
97
CKCB-XCN-YEI
T-11A
85
CKGB-XCN-YVS
T-17A
92
CVGV-XCN-XMD
T-23A
100
CKCB-XCN-YEJ
T-11A
85
CKGB-XCN-YVT
T-17A
92
CVGV-XCN-XME
T-23A
100
CKCB-XCN-YEK
T-11A
85
CKGB-XCN-ZDR
T-17A
90
CVGV-XCN-XMF
T-23A
100
CKCB-XCN-YVM
T-11A
92
CKGB-XCN-ZTJ
T-17A
91
CVGV-XCN-XML
T-23A
100
CKCB-XCN-YVY
T-11A
92
CKGB-XCN-ZTK
T-17A
91
CVGV-XCN-XMM
T-23A
100
CKCB-XCN-ZTC
T-11A
91
CKIB-XCN-HBA
T-19A
199
CVIV-XCN-QAE
T-24A
97
CKCB-XCN-ZTN
T-11A
91
CKIB-XCN-HBB
T-19A
199
CVIV-XCN-QAF
T-24A
97
267
US Selected Assemblies Catalogue #999-901-192
Model Code Index
ASSEMBLIES
Model Code
Cavity
Page
Model Code
Cavity
Page
Model Code
Cavity
Page
CVIV-XCN-QAM
T-24A
97
CWG*-LGN-PAM
T-23A
73
CXCD-X*N-GCJ
T-13A
106
CVIV-XCN-QAN
T-24A
97
CWG*-LGN-XME
T-23A
76
CXDA-X*N-GAA
T-13A
104
CVIV-XCN-XLE
T-24A
100
CWG*-LGN-XMF
T-23A
76
CXDA-X*N-GAB
T-13A
104
CVIV-XCN-XLF
T-24A
100
CWG*-LGN-XML
T-23A
76
CXDA-X*N-GAH
T-13A
104
CVIV-XCN-Z9T
T-24A
98
CWG*-LGN-XMM
T-23A
76
CXDA-X*N-GAI
T-13A
104
CWC*-LGN-MAB
T-21A
72
CWG*-LHN-PAE
T-23A
73
CXDA-X*N-GAJ
T-13A
104
CWC*-LGN-MAC
T-21A
72
CWG*-LHN-PAF
T-23A
73
CXDA-X*N-GCA
T-13A
106
CWC*-LGN-MAI
T-21A
72
CWG*-LHN-PAL
T-23A
73
CXDA-X*N-GCB
T-13A
106
CWC*-LGN-MAJ
T-21A
72
CWG*-LHN-PAM
T-23A
73
CXDA-X*N-GCI
T-13A
106
CWC*-LGN-MAK
T-21A
72
CWG*-LHN-XME
T-23A
76
CXDA-X*N-GCJ
T-13A
106
CWC*-LGN-MBA
T-21A
151
CWG*-LHN-XMF
T-23A
76
CXDA-X*N-GDA
T-13A / T-5A
153
CWC*-LGN-MBB
T-21A
151
CWG*-LHN-XML
T-23A
76
CXDA-X*N-GDP
T-13A / T-5A
153
CWC*-LGN-MBY
T-21A
151
CWG*-LHN-XMM
T-23A
76
CXDA-X*N-GDW
T-13A / T-5A
153
CWC*-LGN-XPB
T-21A
75
CWI*- LHN-XLE
T-24A
76
CXDA-X*N-GDY
T-13A / T-5A
153
CWC*-LGN-XPC
T-21A
75
CWI*- LHN-XLF
T-24A
76
CXED-X*N-DAB
T-5A
104
CWC*-LGN-XPI
T-21A
75
CWI*-LFN-QCE
T-24A
73
CXED-X*N-DAC
T-5A
104
CWC*-LGN-XPJ
T-21A
75
CWI*-LFN-QCF
T-24A
73
CXED-X*N-DAJ
T-5A
104
CWC*-LGN-XPK
T-21A
75
CWI*-LFN-QCM
T-24A
73
CXED-X*N-DAK
T-5A
104
CWC*-LHN-MAB
T-21A
72
CWI*-LFN-QCN
T-24A
73
CXED-X*N-DCB
T-5A
106
CWC*-LHN-MAC
T-21A
72
CWI*-LFN-XLE
T-24A
76
CXED-X*N-DCC
T-5A
106
CWC*-LHN-MAI
T-21A
72
CWI*-LFN-XLF
T-24A
76
CXED-X*N-DCI
T-5A
106
CWC*-LHN-MAJ
T-21A
72
CWI*-LFN-Z9T
T-24A
74
CXED-X*N-DCJ
T-5A
106
CWC*-LHN-MAK
T-21A
72
CWI*-LHN-QCE
T-24A
73
CXED-X*N-DCK
T-5A
106
CWC*-LHN-MBA
T-21A
151
CWI*-LHN-QCF
T-24A
73
CXFA-X*N-DAB
T-5A
104
CWC*-LHN-MBB
T-21A
151
CWI*-LHN-QCM
T-24A
73
CXFA-X*N-DAC
T-5A
104
CWC*-LHN-MBY
T-21A
151
CWI*-LHN-QCN
T-24A
73
CXFA-X*N-DAJ
T-5A
104
CWC*-LHN-XPB
T-21A
75
CWI*-LHN-Z9T
T-24A
74
CXFA-X*N-DAK
T-5A
104
CWC*-LHN-XPC
T-21A
75
CXAD-X*N-AAA
T-162A
104
CXFA-X*N-DCB
T-5A
106
CWC*-LHN-XPI
T-21A
75
CXAD-X*N-AAB
T-162A
104
CXFA-X*N-DCC
T-5A
106
CWC*-LHN-XPJ
T-21A
75
CXAD-X*N-AAH
T-162A
104
CXFA-X*N-DCI
T-5A
106
CWC*-LHN-XPK
T-21A
75
CXAD-X*N-AAI
T-162A
104
CXFA-X*N-DCJ
T-5A
106
CWE*-LFN-NAC
T-22A
72
CXAD-X*N-ACA
T-162A
106
CXFA-X*N-DCK
T-5A
06
CWE*-LFN-NAD
T-22A
72
CXAD-X*N-ACB
T-162A
106
CXFA-X*N-GDF
T-13A
153
CWE*-LFN-NAJ
T-22A
72
CXAD-X*N-ACH
T-162A
106
CXFA-XAN-DBW
T-5A
169
CWE*-LFN-NAK
T-22A
72
CXAD-X*N-ACI
T-162A
106
CXFA-XAN-DJW
T-5A
180
CWE*-LFN-XIC
T-22A
75
CXBA-X*N-AAA
T-162A
104
CXFA-XCN-DBJ
T-5A
169
CWE*-LFN-XID
T-22A
75
CXBA-X*N-AAB
T-162A
104
CXFA-XCN-DBK
T-5A
169
CWE*-LFN-XII
T-22A
75
CXBA-X*N-AAH
T-162A
104
CXFA-XCN-DBP
T-5A
169
CWE*-LFN-XIJ
T-22A
75
CXBA-X*N-AAI
T-162A
104
CXFA-XCN-DJJ
T-5A
180
CWE*-LHN-NAC
T-22A
72
CXBA-X*N-ACA
T-162A
106
CXFA-XCN-DJK
T-5A
180
CWE*-LHN-NAD
T-22A
72
CXBA-X*N-ACB
T-162A
106
CXFA-XCN-DJP
T-5A
180
CWE*-LHN-NAJ
T-22A
72
CXBA-X*N-ACH
T-162A
106
CXGD-X*N-IAD
T-16A
105
CWE*-LHN-NAK
T-22A
72
CXBA-X*N-ACI
T-162A
106
CXGD-X*N-IAE
T-16A
105
CWE*-LHN-XIC
T-22A
75
CXCD-X*N-GAA
T-13A
104
CXGD-X*N-IAF
T-16A
105
CWE*-LHN-XID
T-22A
75
CXCD-X*N-GAB
T-13A
104
CXGD-X*N-IAL
T-16A
105
CWE*-LHN-XIE
T-22A
75
CXCD-X*N-GAH
T-13A
104
CXGD-X*N-IAM
T-16A
105
CWE*-LHN-XII
T-22A
75
CXCD-X*N-GAI
T-13A
104
CXGD-X*N-ICD
T-16A
107
CWE*-LHN-XIJ
T-22A
75
CXCD-X*N-GAJ
T-13A
104
CXGD-X*N-ICE
T-16A
107
CWG*-LGN-PAE
T-23A
73
CXCD-X*N-GCA
T-13A
106
CXGD-X*N-ICF
T-16A
107
CWG*-LGN-PAF
T-23A
73
CXCD-X*N-GCB
T-13A
106
CXGD-X*N-ICL
T-16A
107
CWG*-LGN-PAL
T-23A
73
CXCD-X*N-GCI
T-13A
106
CXGD-X*N-ICM
T-16A
107
US Selected Assemblies Catalogue #999-901-192
268
Model Code Index
ASSEMBLIES
Model Code
Cavity
Page
Model Code
Cavity
Page
Model Code
Cavity
Page
CXHA-X*N-IAD
T-16A
105
FCCB-LAN-GCH
T-13A
122
FDCB-LAN-DAC
T-5A
128
CXHA-X*N-IAE
T-16A
105
FCCB-LAN-GCI
T-13A
122
FDCB-LAN-DAI
T-5A
128
CXHA-X*N-IAF
T-16A
105
FCCB-LAN-GCJ
T-13A
122
FDCB-LAN-DAJ
T-5A
128
CXHA-X*N-IAL
T-16A
105
FCCB-LAN-XWT
T-13A
231
FDCB-LAN-DAK
T-5A
128
CXHA-X*N-IAM
T-16A
105
FCDB-LAN-DAA
T-5A
120
FDCB-LAN-DAW
T-5A
128
CXHA-X*N-ICD
T-16A
107
FCDB-LAN-DAB
T-5A
120
FDCB-LAN-DBA
T-5A
170
CXHA-X*N-ICE
T-16A
107
FCDB-LAN-DAC
T-5A
120
FDCB-LAN-DBB
T-5A
170
CXHA-X*N-ICF
T-16A
107
FCDB-LAN-DAI
T-5A
120
FDCB-LAN-DBC
T-5A
170
CXHA-X*N-ICL
T-16A
107
FCDB-LAN-DAJ
T-5A
120
FDCB-LAN-DBP
T-5A
170
CXHA-X*N-ICM
T-16A
107
FCDB-LAN-DAK
T-5A
120
FDCB-LAN-DBY
T-5A
170
CXHA-XAN-CDV
T-16A
200
FCDB-LAN-DCB
T-5A
122
FDCB-LAN-DCB
T-5A
130
CXHA-XAN-DKX
T-16A
190
FCDB-LAN-DCC
T-5A
122
FDCB-LAN-DCC
T-5A
130
CXHA-XCN-DKP
T-16A
190
FCDB-LAN-DCI
T-5A
122
FDCB-LAN-DCI
T-5A
130
CXHA-XCN-DKT
T-16A
190
FCDB-LAN-DCJ
T-5A
122
FDCB-LAN-DCJ
T-5A
130
CXHA-XCN-DKZ
T-16A
190
FCDB-LAN-DCK
T-5A
122
FDCB-LAN-DCK
T-5A
130
CXID-X*N-VTN
T-18A
108
FCEB-LAN-IAD
T-16A
121
FDCB-LAN-DJA
T-5A
181
CXID-X*N-LAD
T-18A
105
FCEB-LAN-IAE
T-16A
121
FDCB-LAN-DJB
T-5A
181
CXID-X*N-LAE
T-18A
105
FCEB-LAN-IAF
T-16A
121
FDCB-LAN-DJP
T-5A
181
CXID-X*N-LAF
T-18A
105
FCEB-LAN-IAL
T-16A
121
FDCB-LAN-DJY
T-5A
181
CXID-X*N-LAL
T-18A
105
FCEB-LAN-IAM
T-16A
121
FDCB-LAN-WVA
T-5A
240
CXID-X*N-LAM
T-18A
105
FCEB-LAN-ICD
T-16A
123
FDCB-LAN-WXH
T-5A
240
CXID-X*N-ZLR
T-18A
107
FCEB-LAN-ICE
T-16A
123
FDCB-LAN-WZB
T-5A
240
CXID-X*N-ZLS
T-18A
107
FCEB-LAN-ICF
T-16A
123
FDEA-LAN-DKA
T-16A
191
CXID-X*N-XZY
T-18A
108
FCEB-LAN-ICL
T-16A
123
FDEA-LAN-DKB
T-16A
191
CXJA-X*N-LAD
T-18A
105
FCEB-LAN-ICM
T-16A
123
FDEA-LAN-DKP
T-16A
191
CXJA-X*N-LAE
T-18A
105
FCFB-LAN-LAD
T-18A
121
FDEA-LAN-DKY
T-16A
191
CXJA-X*N-LAF
T-18A
105
FCFB-LAN-LAE
T-18A
121
FDEA-LAN-DKZ
T-16A
191
CXJA-X*N-LAL
T-18A
105
FCFB-LAN-LAF
T-18A
121
FDEA-LAN-IAD
T-16A
129
CXJA-X*N-LAM
T-18A
105
FCFB-LAN-LAL
T-18A
121
FDEA-LAN-IAE
T-16A
129
CXJA-X*N-VTN
T-18A
108
FCFB-LAN-LAM
T-18A
121
FDEA-LAN-IAF
T-16A
129
CXJA-X*N-XZY
T-18A
108
FCFB-LAN-VTN
T-18A
124
FDEA-LAN-IAL
T-16A
129
CXJA-X*N-ZLR
T-18A
107
FCFB-LAN-XZY
T-18A
124
FDEA-LAN-IAM
T-16A
129
CXJA-X*N-ZLS
T-18A
107
FCFB-LAN-ZLR
T-18A
123
FDEA-LAN-ICD
T-16A
131
CXJA-XCN-IBO
T-18A
200
FCFB-LAN-ZLS
T-18A
123
FDEA-LAN-ICE
T-16A
131
CXJA-XCN-IBV
T-18A
200
FDBA-LAN-GAA
T-13A
128
FDEA-LAN-ICF
T-16A
131
CXJA-XCN-IBZ
T-18A
200
FDBA-LAN-GAB
T-13A
128
FDEA-LAN-ICL
T-16A
131
FCBB-LAN-AAA
T-162A
120
FDBA-LAN-GAH
T-13A
128
FDEA-LAN-ICM
T-16A
131
FCBB-LAN-AAB
T-162A
120
FDBA-LAN-GAI
T-13A
128
FDFA-LAN-IBE
T-18A
201
FCBB-LAN-AAH
T-162A
120
FDBA-LAN-GAJ
T-13A
128
FDFA-LAN-IBF
T-18A
201
FCBB-LAN-AAI
T-162A
120
FDBA-LAN-GBA
T-13A
155
FDFA-LAN-IBO
T-18A
201
FCBB-LAN-ACA
T-162A
122
FDBA-LAN-GBP
T-13A
154
FDFA-LAN-IBY
T-18A
201
FCBB-LAN-ACB
T-162A
122
FDBA-LAN-GBW
T-13A
155
FDFA-LAN-IBZ
T-18A
201
FCBB-LAN-ACH
T-162A
122
FDBA-LAN-GBX
T-13A
155
FDFA-LAN-LAD
T-18A
129
FCBB-LAN-ACI
T-162A
122
FDBA-LAN-GBY
T-13A
155
FDFA-LAN-LAE
T-18A
129
FCCB-LAN-GAA
T-13A
120
FDBA-LAN-GCA
T-13A
130
FDFA-LAN-LAF
T-18A
129
FCCB-LAN-GAB
T-13A
120
FDBA-LAN-GCB
T-13A
130
FDFA-LAN-LAL
T-18A
129
FCCB-LAN-GAH
T-13A
120
FDBA-LAN-GCH
T-13A
130
FDFA-LAN-LAM
T-18A
129
FCCB-LAN-GAI
T-13A
120
FDBA-LAN-GCI
T-13A
130
FDFA-LAN-VTN
T-18A
132
FCCB-LAN-GAJ
T-13A
120
FDBA-LAN-GCJ
T-13A
130
FDFA-LAN-XZY
T-18A
132
FCCB-LAN-GCA
T-13A
122
FDCB-LAN-DAA
T-5A
128
FDFA-LAN-ZLR
T-18A
131
FCCB-LAN-GCB
T-13A
122
FDCB-LAN-DAB
T-5A
128
FDFA-LAN-ZLS
T-18A
131
269
US Selected Assemblies Catalogue #999-901-192
Model Code Index
ASSEMBLIES
Model Code
Cavity
Page
Model Code
Cavity
Page
Model Code
Cavity
Page
FRBA-LAN-JCA
T-163A
136
FXEA-LAN-IAD
T-16A
121
NCEB-L*N-DCK
T-5A
114
FRBA-LAN-JCB
T-163A
136
FXEA-LAN-IAE
T-16A
121
NCEB-LAN-DBA
T-5A
170
FRBA-LAN-JCH
T-163A
136
FXEA-LAN-IAF
T-16A
121
NCEB-LAN-DBB
T-5A
170
FRBA-LAN-JCI
T-163A
136
FXEA-LAN-IAL
T-16A
121
NCEB-LAN-DBC
T-5A
170
FRCA-LAN-EAB
T-11A
136
FXEA-LAN-IAM
T-16A
121
NCEB-LAN-DBY
T-5A
170
FRCA-LAN-EAC
T-11A
136
FXEA-LAN-ICD
T-16A
123
NCEB-LCN-DJA
T-5A
181
FRCA-LAN-EAJ
T-11A
136
FXEA-LAN-ICE
T-16A
123
NCEB-LCN-DJB
T-5A
181
FRCA-LAN-EAK
T-11A
136
FXEA-LAN-ICF
T-16A
123
NCEB-LCN-DJY
T-5A
181
FRCA-LAN-WBN
T-11A
154
FXEA-LAN-ICL
T-16A
123
NCFB-L*N-DKA
T-16A
191
FRDA-LAN-BAB
T-2A
136
FXEA-LAN-ICM
T-16A
123
NCFB-L*N-DKB
T-16A
191
FRDA-LAN-BAC
T-2A
136
FXFA-LAN-LAD
T-18A
121
NCFB-L*N-IAD
T-16A
113
FRDA-LAN-BAD
T-2A
136
FXFA-LAN-LAE
T-18A
121
NCFB-L*N-IAE
T-16A
113
FRDA-LAN-BAJ
T-2A
136
FXFA-LAN-LAF
T-18A
121
NCFB-L*N-IAF
T-16A
113
FRDA-LAN-BAK
T-2A
136
FXFA-LAN-LAL
T-18A
121
NCFB-L*N-IAL
T-16A
113
FRDA-LAN-BAL
T-2A
136
FXFA-LAN-LAM
T-18A
121
NCFB-L*N-IAM
T-16A
113
FREA-LAN-HED
T-17A
137
FXFA-LAN-VTN
T-18A
124
NCFB-L*N-ICD
T-16A
115
FREA-LAN-HEE
T-17A
137
FXFA-LAN-XZY
T-18A
124
NCFB-L*N-ICE
T-16A
115
FREA-LAN-HEF
T-17A
137
FXFA-LAN-ZLR
T-18A
123
NCFB-L*N-ICF
T-16A
115
FREA-LAN-HEL
T-17A
137
FXFA-LAN-ZLS
T-18A
123
NCFB-L*N-ICL
T-16A
115
FREA-LAN-HEM
T-17A
137
NCBB-L*N-AAA
T-162A
112
NCFB-L*N-ICM
T-16A
115
FRFA-LAN-KEE
T-19A
137
NCBB-L*N-AAB
T-162A
112
NCGB-L*N-LAD
T-18A
113
FRFA-LAN-KEF
T-19A
137
NCBB-L*N-AAH
T-162A
112
NCGB-L*N-LAE
T-18A
113
FXBA-LAN-AAA
T-162A
120
NCBB-L*N-AAI
T-162A
112
NCGB-L*N-LAF
T-18A
113
FXBA-LAN-AAB
T-162A
120
NCBB-L*N-ACA
T-162A
114
NCGB-L*N-LAL
T-18A
113
FXBA-LAN-AAH
T-162A
120
NCBB-L*N-ACB
T-162A
114
NCGB-L*N-LAM
T-18A
113
FXBA-LAN-AAI
T-162A
120
NCBB-L*N-ACH
T-162A
114
NCGB-L*N-VTN
T-18A
116
FXBA-LAN-ACA
T-162A
122
NCBB-L*N-ACI
T-162A
114
NCGB-L*N-XZY
T-18A
116
FXBA-LAN-ACB
T-162A
122
NCCB-L*N-GAA
T-13A
112
NCGB-L*N-ZLR
T-18A
115
FXBA-LAN-ACH
T-162A
122
NCCB-L*N-GAB
T-13A
112
NCGB-L*N-ZLS
T-18A
115
FXBA-LAN-ACI
T-162A
122
NCCB-L*N-GAH
T-13A
112
NCGB-LCN-IBE
T-18A
201
FXCA-LAN-GAA
T-13A
120
NCCB-L*N-GAI
T-13A
112
NCGB-LCN-IBF
T-18A
201
FXCA-LAN-GAB
T-13A
120
NCCB-L*N-GAJ
T-13A
112
NCGB-LCN-IBY
T-18A
201
FXCA-LAN-GAH
T-13A
120
NCCB-L*N-GCA
T-13A
114
NCGB-LCN-IBZ
T-18A
201
FXCA-LAN-GAI
T-13A
120
NCCB-L*N-GCB
T-13A
114
NFBC-L*N-AAA
T-162A
112
FXCA-LAN-GAJ
T-13A
120
NCCB-L*N-GCH
T-13A
114
NFBC-L*N-AAB
T-162A
112
FXCA-LAN-GCA
T-13A
122
NCCB-L*N-GCI
T-13A
114
NFBC-L*N-AAH
T-162A
112
FXCA-LAN-GCB
T-13A
122
NCCB-L*N-GCJ
T-13A
114
NFBC-L*N-AAI
T-162A
112
FXCA-LAN-GCH
T-13A
122
NCCB-LAN-GBW
T-13A
155
NFBC-L*N-ACA
T-162A
114
FXCA-LAN-GCI
T-13A
122
NCCB-LAN-GBX
T-13A
155
NFBC-L*N-ACB
T-162A
114
FXCA-LAN-GCJ
T-13A
122
NCCB-LCN-GBA
T-13A
155
NFBC-L*N-ACH
T-162A
114
FXDA-LAN-DAA
T-5A
120
NCCB-LCN-GBY
T-13A
155
NFBC-L*N-ACI
T-162A
114
FXDA-LAN-DAB
T-5A
120
NCEB-L*N-DAA
T-5A
112
NFCB-L*N-DKY
T-16A
191
FXDA-LAN-DAC
T-5A
120
NCEB-L*N-DAB
T-5A
112
NFCB-L*N-DKZ
T-16A
191
FXDA-LAN-DAI
T-5A
120
NCEB-L*N-DAC
T-5A
112
NFCC-L*N-GAA
T-13A
112
FXDA-LAN-DAJ
T-5A
120
NCEB-L*N-DAI
T-5A
112
NFCC-L*N-GAB
T-13A
112
FXDA-LAN-DAK
T-5A
120
NCEB-L*N-DAJ
T-5A
112
NFCC-L*N-GAH
T-13A
112
FXDA-LAN-DCB
T-5A
122
NCEB-L*N-DAK
T-5A
112
NFCC-L*N-GAI
T-13A
112
FXDA-LAN-DCC
T-5A
122
NCEB-L*N-DCB
T-5A
114
NFCC-L*N-GAJ
T-13A
112
FXDA-LAN-DCI
T-5A
122
NCEB-L*N-DCC
T-5A
114
NFCC-L*N-GCA
T-13A
114
FXDA-LAN-DCJ
T-5A
122
NCEB-L*N-DCI
T-5A
114
NFCC-L*N-GCB
T-13A
114
FXDA-LAN-DCK
T-5A
122
NCEB-L*N-DCJ
T-5A
114
NFCC-L*N-GCH
T-13A
114
US Selected Assemblies Catalogue #999-901-192
270
Model Code Index
ASSEMBLIES
Model Code
Cavity
Page
Model Code
Cavity
Page
Model Code
Cavity
NFCC-L*N-GCI
T-13A
114
PBDB-LAN-E6C
T-11A
39
PBJB-LAN-K2*
T-19A
40
NFCC-L*N-GCJ
T-13A
114
PBDB-LAN-E6I
T-11A
39
PBJB-LAN-KF6
T-19-A
38
NFCC-LAN-DBS
T-13A
171
PBDB-LAN-E6J
T-11A
39
PBJB-LAN-KFE
T-19-A
37
NFCC-LCN-DJS
T-13A
182
PBDB-LAN-EB2
T-11A
149
PBJB-LAN-KFF
T-19-A
37
NFCC-LCN-GBP
T-13A
154
PBDB-LAN-EB3
T-11A
149
PBJB-LAN-KFR
T-19-A
38
NFCC-LCN-GBS
T-13A
154
PBDB-LAN-EBA
T-11A
149
PPDB-LAN-E4B
T-11A
47
NFCC-LCN-GBW
T-13A
154
PBDB-LAN-EBP
T-11A
149
PPDB-LAN-E4C
T-11A
47
NFCC-LCN-GBX
T-13A
154
PBDB-LAN-EBY
T-11A
149
PPDB-LAN-E4I
T-11A
47
NFCC-LCN-ZFZ
T-13A
232
PBDB-LAN-EFB
T-11A
36
PPDB-LAN-E4J
T-11A
47
NFDC-L*N-DAA
T-5A
112
PBDB-LAN-EFC
T-11A
36
PPDB-LAN-E4K
T-11A
47
NFDC-L*N-DAB
T-5A
112
PBDB-LAN-EFH
T-11A
36
PPDB-LAN-EB2
T-11A
150
NFDC-L*N-DAC
T-5A
112
PBDB-LAN-EFI
T-11A
36
PPDB-LAN-EB3
T-11A
150
NFDC-L*N-DAI
T-5A
112
PBDB-LAN-EFJ
T-11A
36
PPDB-LAN-EBA
T-11A
150
NFDC-L*N-DAJ
T-5A
112
PBFB-LAN-B6B
T-2A
39
PPDB-LAN-EBP
T-11A
150
NFDC-L*N-DAK
T-5A
112
PBFB-LAN-B6C
T-2A
39
PPDB-LAN-EBY
T-11A
150
NFDC-L*N-DCB
T-5A
114
PBFB-LAN-B6D
T-2A
39
PPDB-LAN-ELB
T-11A
44
NFDC-L*N-DCC
T-5A
114
PBFB-LAN-B6I
T-2A
39
PPDB-LAN-ELC
T-11A
44
NFDC-L*N-DCI
T-5A
114
PBFB-LAN-B6J
T-2A
39
PPDB-LAN-ELI
T-11A
44
NFDC-L*N-DCJ
T-5A
114
PBFB-LAN-BB2
T-2A
165
PPDB-LAN-ELJ
T-11A
44
NFDC-L*N-DCK
T-5A
114
PBFB-LAN-BB3
T-2A
165
PPDB-LAN-ELK
T-11A
44
NFDC-LAN-DBP
T-5A
170
PBFB-LAN-BBA
T-2A
165
PPFB-LAN-B4C
T-2A
47
NFDC-LAN-DJP
T-5A
181
PBFB-LAN-BBB
T-2A
165
PPFB-LAN-B4D
T-2A
47
NFEC-L*N-IAD
T-16A
113
PBFB-LAN-BBP
T-2A
165
PPFB-LAN-B4J
T-2A
47
NFEC-L*N-IAE
T-16A
113
PBFB-LAN-BFC
T-2A
36
PPFB-LAN-B4K
T-2A
47
NFEC-L*N-IAF
T-16A
113
PBFB-LAN-BFD
T-2A
36
PPFB-LAN-BB2
T-2A
166
NFEC-L*N-IAL
T-16A
113
PBFB-LAN-BFH
T-2A
36
PPFB-LAN-BB3
T-2A
166
NFEC-L*N-IAM
T-16A
113
PBFB-LAN-BFI
T-2A
36
PPFB-LAN-BBP
T-2A
166
NFEC-L*N-ICD
T-16A
115
PBFB-LAN-BJ2
T-2A
176
PPFB-LAN-BJ2
T-2A
177
NFEC-L*N-ICE
T-16A
115
PBFB-LAN-BJ3
T-2A
176
PPFB-LAN-BJ3
T-2A
177
NFEC-L*N-ICF
T-16A
115
PBFB-LAN-BJA
T-2A
176
PPFB-LAN-BJA
T-2A
177
NFEC-L*N-ICL
T-16A
115
PBFB-LAN-BJB
T-2A
176
PPFB-LAN-BJB
T-2A
177
NFEC-L*N-ICM
T-16A
115
PBFB-LAN-BJP
T-2A
176
PPFB-LAN-BJP
T-2A
177
NFEC-LEN-DKP
T-16A
191
PBHB-LAN-BK2
T-17A
186
PPFB-LAN-BLC
T-2A
44
NFFC-L*N-LAD
T-18A
113
PBHB-LAN-BKA
T-17A
186
PPFB-LAN-BLD
T-2A
44
NFFC-L*N-LAE
T-18A
113
PBHB-LAN-BKB
T-17A
186
PPFB-LAN-BLI
T-2A
44
NFFC-L*N-LAF
T-18A
113
PBHB-LAN-BKJ
T-17A
186
PPFB-LAN-BLJ
T-2A
44
NFFC-L*N-LAL
T-18A
113
PBHB-LAN-BKP
T-17A
186
PPFB-LAN-BLK
T-2A
44
NFFC-L*N-LAM
T-18A
113
PBHB-LAN-H2*
T-17A
40
PPHB-LAN-BK2
T-17A
187
NFFC-L*N-VTN
T-18A
116
PBHB-LAN-H2*
T-17A
40
PPHB-LAN-BKA
T-17A
187
NFFC-L*N-XZY
T-18A
116
PBHB-LAN-H2*
T-17A
40
PPHB-LAN-BKB
T-17A
187
NFFC-L*N-ZLR
T-18A
115
PBHB-LAN-H2*
T-17A
40
PPHB-LAN-BKJ
T-17A
187
NFFC-L*N-ZLS
T-18A
115
PBHB-LAN-HBJ
T-17A
196
PPHB-LAN-BKP
T-17A
187
NFFC-LGN-IBO
T-18A
201
PBHB-LAN-HBK
T-17A
196
PPHB-LAN-H4E
T-17A
48
PBBB-LAN-J2A
T-163A
39
PBHB-LAN-HFE
T-17A
37
PPHB-LAN-H4F
T-17A
48
PBBB-LAN-J2B
T-163A
39
PBHB-LAN-HFF
T-17A
37
PPHB-LAN-H4L
T-17A
48
PBBB-LAN-J2H
T-163A
39
PBHB-LAN-HFL
T-17A
37
PPHB-LAN-H4M
T-17A
48
PBBB-LAN-J2I
T-163A
39
PBHB-LAN-HFM
T-17A
37
PPHB-LAN-HBJ
T-17A
197
PBBB-LAN-JFB
T-163A
36
PBJB-LAN-HBA
T-19A
196
PPHB-LAN-HBK
T-17A
197
PBBB-LAN-JFH
T-163A
36
PBJB-LAN-HBB
T-19A
196
PPHB-LAN-HEE
T-17A
45
PBBB-LAN-JFI
T-163A
36
PBJB-LAN-HBO
T-19A
196
PPHB-LAN-HEF
T-17A
45
PBDB-LAN-E6B
T-11A
39
PBJB-LAN-K2*
T-19A
40
PPHB-LAN-HEL
T-17A
45
271
Page
US Selected Assemblies Catalogue #999-901-192
Model Code Index
ASSEMBLIES
Model Code
Cavity
Page
Model Code
Cavity
Page
Model Code
Cavity
Page
PPHB-LAN-HEM
T-17A
45
PRHB-LAN-H4L
T-17A
48
RDDA-LAN-FAD
T-10A
4
PPJB-LAN-HBA
T-19A
197
PRHB-LAN-H4M
T-17A
48
RDDA-LAN-FAK
T-10A
4
PPJB-LAN-HBB
T-19A
197
PRHB-LAN-HBJ
T-17A
197
RDDA-LAN-FAL
T-10A
4
PPJB-LAN-HBO
T-19A
197
PRHB-LAN-HBK
T-17A
197
RDDA-LAN-FBA
T-10A
146
PPJB-LAN-K4E
T-19A
48
PRHB-LAN-HEE
T-17A
45
RDDA-LAN-FBC
T-10A
146
PPJB-LAN-K4F
T-19A
48
PRHB-LAN-HEF
T-17A
45
RDDA-LAN-FBP
T-10A
146
PPJB-LAN-KE6
T-19A
46
PRHB-LAN-HEL
T-17A
45
RDDA-LAN-FBX
T-10A
146
PPJB-LAN-KEE
T-19A
45
PRHB-LAN-HEM
T-17A
45
RDDA-LAN-FBY
T-10A
146
PPJB-LAN-KEF
T-19A
45
PRJB-LAN-HBA
T-19A
197
RDDA-LAN-FEB
T-10A
6
PPJB-LAN-KEM
T-19A
45
PRJB-LAN-HBB
T-19A
197
RDDA-LAN-FEC
T-10A
6
PPJB-LAN-KEN
T-19A
45
PRJB-LAN-HBO
T-19A
197
RDDA-LAN-FEI
T-10A
6
PPJB-LAN-KER
T-19A
46
PRJB-LAN-K4E
T-19A
48
RDDA-LAN-FEJ
T-10A
6
PRDB-LAN-E4B
T-11A
47
PRJB-LAN-K4F
T-19A
48
RDDA-LAN-FRB
T-10A
145
PRDB-LAN-E4C
T-11A
47
PRJB-LAN-KE6
T-19A
46
RDDA-LAN-FRC
T-10A
161
PRDB-LAN-E4I
T-11A
47
PRJB-LAN-KEE
T-19A
45
RDDA-LAN-FRJ
T-10A
145
PRDB-LAN-E4J
T-11A
47
PRJB-LAN-KEF
T-19A
45
RDDA-LAN-FRK
T-10A
161
PRDB-LAN-E4K
T-11A
47
PRJB-LAN-KEM
T-19A
45
RDDA-LAN-FSB
T-10A
145
PRDB-LAN-EB2
T-11A
150
PRJB-LAN-KEN
T-19A
45
RDDA-LAN-FSC
T-10A
161
PRDB-LAN-EB3
T-11A
150
PRJB-LAN-KER
T-19A
46
RDDA-LAN-FSJ
T-10A
145
PRDB-LAN-EBA
T-11A
150
RDBA-LAN-AAA
T-162A
4
RDDA-LAN-FSK
T-10A
161
PRDB-LAN-EBP
T-11A
150
RDBA-LAN-AAB
T-162A
4
RDDA-LAN-FTC
T-10A
161
PRDB-LAN-EBY
T-11A
150
RDBA-LAN-AAH
T-162A
4
RDDA-LAN-FTK
T-10A
161
PRDB-LAN-ELB
T-11A
44
RDBA-LAN-AAI
T-162A
4
RDDA-LAN-YFB
T-10A
9
PRDB-LAN-ELC
T-11A
44
RDBA-LAN-AEA
T-162A
6
RDDA-LAN-YFC
T-10A
9
PRDB-LAN-ELI
T-11A
4
RDBA-LAN-AEB
T-162A
6
RDDA-LAN-YFI
T-10A
9
PRDB-LAN-ELJ
T-11A
44
RDBA-LAN-AEH
T-162A
6
RDDA-LAN-YFJ
T-10A
9
PRDB-LAN-ELK
T-11A
44
RDBA-LAN-AEI
T-162A
6
RDDA-LAN-ZHH
T-10A
173
PRFB-LAN-B4C
T-2A
47
RDBA-LAN-AYA
T-162A
9
RDDA-LAN-ZHJ
T-10A
173
PRFB-LAN-B4D
T-2A
47
RDBA-LAN-AYB
T-162A
9
RDDA-LAN-ZHK
T-10A
173
PRFB-LAN-B4J
T-2A
47
RDBA-LAN-AYH
T-162A
9
RDDA-LAN-ZHL
T-10A
173
PRFB-LAN-B4K
T-2A
47
RDBA-LAN-AYI
T-162A
9
RDDA-LAN-ZHP
T-10A
173
PRFB-LAN-BB2
T-2A
166
RDDA-L*N-WLL
T-10A
241
RDDA-LAN-ZHQ
T-10A
173
PRFB-LAN-BB3
T-2A
166
RDDA-L*N-WLY
T-10A
241
RDDA-LAN-ZHR
T-10A
173
PRFB-LAN-BBP
T-2A
166
RDDA-L*N-WMV
T-10A
241
RDDA-LAN-ZHS
T-10A
173
PRFB-LAN-BJ2
T-2A
177
RDDA-L*N-WVP
T-10A
238
RDFA-LAN-CAC
T-3A
4
PRFB-LAN-BJ3
T-2A
177
RDDA-L*N-WVS
T-10A
238
RDFA-LAN-CAD
T-3A
4
PRFB-LAN-BJA
T-2A
177
RDDA-L*N-WVY
T-10A
238
RDFA-LAN-CAH
T-3A
4
PRFB-LAN-BJB
T-2A
177
RDDA-L*N-YVP
T-10A
235
RDFA-LAN-CAI
T-3A
4
PRFB-LAN-BJP
T-2A
177
RDDA-L*N-YWA
T-10A
233
RDFA-LAN-CEJ
T-3A
6
PRFB-LAN-BLC
T-2A
44
RDDA-L*N-YXB
T-10A
230
RDFA-LAN-CEL
T-3A
6
PRFB-LAN-BLD
T-2A
44
RDDA-L*N-ZFK
T-10A
230
RDFA-LAN-CJA
T-3A
174
PRFB-LAN-BLI
T-2A
44
RDDA-L*N-ZFK
T-10A
230
RDFA-LAN-CJB
T-3A
174
PRFB-LAN-BLJ
T-2A
44
RDDA-LAN-CBD
T-10A
162
RDFA-LAN-CJP
T-3A
174
PRFB-LAN-BLK
T-2A
44
RDDA-LAN-CBE
T-10A
162
RDFA-LAN-CJX
T-3A
174
PRHB-LAN-BK2
T-17A
187
RDDA-LAN-CBF
T-10A
162
RDFA-LAN-CKA
T-3A
184
PRHB-LAN-BKA
T-17A
187
RDDA-LAN-CBG
T-10A
162
RDFA-LAN-CKB
T-3A
184
PRHB-LAN-BKB
T-17A
187
RDDA-LAN-CBH
T-10A
163
RDFA-LAN-CKP
T-3A
184
PRHB-LAN-BKJ
T-17A
187
RDDA-LAN-CBI
T-10A
162
RDFA-LAN-CKX
T-3A
184
PRHB-LAN-BKP
T-17A
187
RDDA-LAN-CJY
T-10A
174
RDFA-LAN-CRE
T-3A
193
PRHB-LAN-H4E
T-17A
48
RDDA-LAN-CKY
T-10A
184
RDFA-LAN-CRM
T-3A
193
PRHB-LAN-H4F
T-17A
48
RDDA-LAN-FAC
T-10A
4
RDFA-LAN-CSE
T-3A
193
US Selected Assemblies Catalogue #999-901-192
272
Model Code Index
ASSEMBLIES
Model Code
Cavity
Page
Model Code
Cavity
Page
Model Code
Cavity
Page
RDFA-LAN-CSM
T-3A
193
RPCC-LAN-AYH
T-162A
9
RPGC-LAN-CJA
T-3A
174
RDFA-LAN-CTE
T-3A
193
RPCC-LAN-AYI
T-162A
9
RPGC-LAN-CJB
T-3A
174
RDFA-LAN-CTM
T-3A
193
RPEC-LAN-CBD
T-10A
162
RPGC-LAN-CJP
T-3A
174
RDFA-LAN-VTE
T-3A
183
RPEC-LAN-CBE
T-10A
162
RPGC-LAN-CJX
T-3A
174
RDFA-LAN-YCD
T-3A
9
RPEC-LAN-CBF
T-10A
162
RPGC-LAN-CKA
T-3A
184
RDFA-LAN-YCE
T-3A
9
RPEC-LAN-CBG
T-10A
162
RPGC-LAN-CKB
T-3A
184
RDFA-LAN-YCL
T-3A
9
RPEC-LAN-CBH
T-10A
163
RPGC-LAN-CKP
T-3A
184
RDFA-LAN-YCM
T-3A
9
RPEC-LAN-CBI
T-10A
162
RPGC-LAN-CKX
T-3A
184
RDFA-LAN-ZLF
T-3A
183
RPEC-LAN-CJY
T-10A
174
RPGC-LAN-CRE
T-3A
193
RDFA-LAN-ZLW
T-3A
183
RPEC-LAN-CKY
T-10A
184
RPGC-LAN-CRM
T-3A
193
RDFA-LAN-ZLX
T-3A
183
RPEC-LAN-FAC
T-10A
4
RPGC-LAN-CSE
T-3A
193
RDHA-LAN-CDC
T-16A
194
RPEC-LAN-FAD
T-10A
4
RPGC-LAN-CSM
T-3A
193
RDHA-LAN-CDD
T-16A
194
RPEC-LAN-FAK
T-10A
4
RPGC-LAN-CTE
T-3A
193
RDHA-LAN-CDO
T-16A
194
RPEC-LAN-FAL
T-10A
4
RPGC-LAN-CTM
T-3A
193
RDHA-LAN-CDW
T-16A
194
RPEC-LAN-FBA
T-10A
146
RPGC-LAN-VTE
T-3A
183
RDHA-LAN-CDZ
T-16A
194
RPEC-LAN-FBC
T-10A
146
RPGC-LAN-YCD
T-3A
9
RDHA-LAN-IAD
T-16A
5
RPEC-LAN-FBP
T-10A
146
RPGC-LAN-YCE
T-3A
9
RDHA-LAN-IAE
T-16A
5
RPEC-LAN-FBX
T-10A
146
RPGC-LAN-YCL
T-3A
9
RDHA-LAN-IAF
T-16A
5
RPEC-LAN-FBY
T-10A
146
RPGC-LAN-YCM
T-3A
9
RDHA-LAN-IAL
T-16A
5
RPEC-LAN-FEB
T-10A
6
RPGC-LAN-ZLF
T-3A
183
RDHA-LAN-IAM
T-16A
5
RPEC-LAN-FEC
T-10A
6
RPGC-LAN-ZLW
T-3A
183
RDHA-LAN-IEE
T-16A
7
RPEC-LAN-FEI
T-10A
6
RPGC-LAN-ZLX
T-3A
183
RDHA-LAN-IEF
T-16A
7
RPEC-LAN-FEJ
T-10A
6
RPIC-LAN-CDC
T-16A
194
RDHA-LAN-IEL
T-16A
7
RPEC-LAN-FRB
T-10A
145
RPIC-LAN-CDD
T-16A
194
RDHA-LAN-IEM
T-16A
7
RPEC-LAN-FRC
T-10A
161
RPIC-LAN-CDO
T-16A
194
RDHA-LAN-YIF
T-16A
10
RPEC-LAN-FRJ
T-10A
145
RPIC-LAN-CDW
T-16A
194
RDHA-LAN-YIN
T-16A
10
RPEC-LAN-FRK
T-10A
161
RPIC-LAN-CDZ
T-16A
194
RDJA-LAN-LA6
T-18A
5
RPEC-LAN-FSB
T-10A
145
RPIC-LAN-IAD
T-16A
5
RDJA-LAN-LAD
T-18A
5
RPEC-LAN-FSC
T-10A
161
RPIC-LAN-IAE
T-16A
5
RDJA-LAN-LAE
T-18A
5
RPEC-LAN-FSJ
T-10A
145
RPIC-LAN-IAF
T-16A
5
RDJA-LAN-LAF
T-18A
5
RPEC-LAN-FSK
T-10A
161
RPIC-LAN-IAL
T-16A
5
RDJA-LAN-LAL
T-18A
5
RPEC-LAN-FTC
T-10A
161
RPIC-LAN-IAM
T-16A
5
RDJA-LAN-LAM
T-18A
5
RPEC-LAN-FTK
T-10A
161
RPIC-LAN-IEE
T-16A
7
RDJA-LAN-LEE
T-18A
7
RPEC-LAN-YFB
T-10A
9
RPIC-LAN-IEF
T-16A
7
RDJA-LAN-LEF
T-18A
7
RPEC-LAN-YFC
T-10A
9
RPIC-LAN-IEL
T-16A
7
RDJA-LAN-LEL
T-18A
7
RPEC-LAN-YFI
T-10A
9
RPIC-LAN-IEM
T-16A
7
RDJA-LAN-LEM
T-18A
7
RPEC-LAN-YFJ
T-10A
9
RPIC-LAN-YIF
T-16A
10
RDJA-LAN-VTN
T-18A
8
RPEC-LAN-ZHH
T-10A
173
RPIC-LAN-YIN
T-16A
10
RDJA-LAN-XYZ
T-18A
8
RPEC-LAN-ZHJ
T-10A
173
RPKC-LAN-LA6
T-18A
5
RDJA-LAN-YL6
T-18A
10
RPEC-LAN-ZHK
T-10A
173
RPKC-LAN-LAD
T-18A
5
RDJA-LAN-YLR
T-18A
10
RPEC-LAN-ZHL
T-10A
173
RPKC-LAN-LAE
T-18A
5
RPCC-LAN-AAA
T-162A
4
RPEC-LAN-ZHP
T-10A
173
RPKC-LAN-LAF
T-18A
5
RPCC-LAN-AAB
T-162A
4
RPEC-LAN-ZHQ
T-10A
173
RPKC-LAN-LAL
T-18A
5
RPCC-LAN-AAH
T-162A
4
RPEC-LAN-ZHR
T-10A
173
RPKC-LAN-LAM
T-18A
5
RPCC-LAN-AAI
T-162A
4
RPEC-LAN-ZHS
T-10A
173
RPKC-LAN-LEE
T-18A
7
RPCC-LAN-AEA
T-162A
6
RPGC-LAN-CAC
T-3A
4
RPKC-LAN-LEF
T-18A
7
RPCC-LAN-AEB
T-162A
6
RPGC-LAN-CAD
T-3A
4
RPKC-LAN-LEL
T-18A
7
RPCC-LAN-AEH
T-162A
6
RPGC-LAN-CAH
T-3A
4
RPKC-LAN-LEM
T-18A
7
RPCC-LAN-AEI
T-162A
6
RPGC-LAN-CAI
T-3A
4
RPKC-LAN-VTN
T-18A
8
RPCC-LAN-AYA
T-162A
9
RPGC-LAN-CEJ
T-3A
6
RPKC-LAN-XYZ
T-18A
8
RPCC-LAN-AYB
T-162A
9
RPGC-LAN-CEL
T-3A
6
RPKC-LAN-YL6
T-18A
10
273
US Selected Assemblies Catalogue #999-901-192
Model Code Index
ASSEMBLIES
Model Code
Cavity
Page
Model Code
Cavity
Page
Model Code
Cavity
Page
RPKC-LAN-YLR
T-18A
10
RSHC-LAN-H6L
T-17A
25
SCEA-LAN-BCI
T-2A
30
RS*C-LAN-EB4
T-11A
148
RSHC-LAN-H6M
T-17A
25
SCGA-LAN-HCE
T-17A
31
RS*C-LAN-EB5
T-11A
148
RSHC-LAN-H8E
T-17A
26
SCGA-LAN-HCF
T-17A
31
RSBC-LAN-J6*
T-163A
24
RSHC-LAN-H8F
T-17A
26
SCGA-LAN-HCL
T-17A
31
RSBC-LAN-J6*
T-163A
24
RSHC-LAN-HB4
T-17A
195
SCGA-LAN-HCM
T-17A
31
RSBC-LAN-J6*
T-163A
24
RSHC-LAN-HB6
T-17A
195
SCIA-LAN-KCE
T-19A
31
RSBC-LAN-J6*
T-163A
24
RSHC-LAN-HB7
T-17A
195
SCIA-LAN-KCF
T-19A
31
RSBC-LAN-JCA
T-163A
22
RSHC-LAN-HBW
T-17A
195
SXCA-LAN-E6B
T-11A
24
RSBC-LAN-JCB
T-163A
22
RSHC-LAN-HCE
T-17A
23
SXCA-LAN-E6C
T-11A
24
RSBC-LAN-JCH
T-163A
22
RSHC-LAN-HCF
T-17A
23
SXCA-LAN-E6I
T-11A
24
RSBC-LAN-JCI
T-163A
22
RSHC-LAN-HCL
T-17A
23
SXCA-LAN-E6J
T-11A
24
RSDC-LAN-E6B
T-11A
24
RSHC-LAN-HCM
T-17A
23
SXCA-LAN-E6K
T-11A
24
RSDC-LAN-E6C
T-11A
24
RSJC-LAN-K6E
T-19A
25
SXCA-LAN-E8B
T-11A
26
RSDC-LAN-E6I
T-11A
24
RSJC-LAN-K6F
T-19A
25
SXCA-LAN-E8C
T-11A
26
RSDC-LAN-E6J
T-11A
24
RSJC-LAN-KCE
T-19A
23
SXCA-LAN-E8I
T-11A
26
RSDC-LAN-E6K
T-11A
24
RSJC-LAN-KCF
T-19A
23
SXCA-LAN-E8J
T-11A
26
RSDC-LAN-E8B
T-11A
26
RVBA-LAN-JCA
T-163A
14
SXCA-LAN-EB4
T-11A
148
RSDC-LAN-E8C
T-11A
26
RVBA-LAN-JCB
T-163A
14
SXCA-LAN-EB5
T-11A
148
RSDC-LAN-E8I
T-11A
26
RVBA-LAN-JCH
T-163A
14
SXCA-LAN-EBW
T-11A
148
RSDC-LAN-E8J
T-11A
26
RVBA-LAN-JCI
T-163A
14
SXCA-LAN-ECB
T-11A
22
RSDC-LAN-ECB
T-11A
22
RVCA-LAN-ECB
T-11A
14
SXCA-LAN-ECC
T-11A
22
RSDC-LAN-ECC
T-11A
22
RVCA-LAN-ECC
T-11A
14
SXCA-LAN-ECH
T-11A
22
RSDC-LAN-ECH
T-11A
22
RVCA-LAN-ECH
T-11A
14
SXCA-LAN-ECI
T-11A
22
RSDC-LAN-ECI
T-11A
22
RVCA-LAN-ECI
T-11A
14
SXCA-LAN-ECJ
T-11A
22
RSDC-LAN-ECJ
T-11A
22
RVCA-LAN-ECJ
T-11A
14
SXEA-LAN-B6B
T-2A
24
RSDG-LAN-EBW/M
T-11A
148
RVEA-LAN-BBC
T-2A
163
SXEA-LAN-B6C
T-2A
24
RSFC-LAN-B6B
T-2A
24
RVEA-LAN-BCC
T-2A
14
SXEA-LAN-B6D
T-2A
24
RSFC-LAN-B6C
T-2A
24
RVEA-LAN-BCD
T-2A
14
SXEA-LAN-B6J
T-2A
24
RSFC-LAN-B6D
T-2A
24
RVEA-LAN-BCI
T-2A
14
SXEA-LAN-B6K
T-2A
24
RSFC-LAN-B6J
T-2A
24
RVEA-LAN-BCJ
T-2A
14
SXEA-LAN-B8C
T-2A
26
RSFC-LAN-B6K
T-2A
24
RVGA-LAN-HCD
T-17A
15
SXEA-LAN-B8D
T-2A
26
RSFC-LAN-B8C
T-2A
26
RVGA-LAN-HCE
T-17A
15
SXEA-LAN-B8J
T-2A
26
RSFC-LAN-B8D
T-2A
26
RVGA-LAN-HCF
T-17A
15
SXEA-LAN-BB4
T-2A
164
RSFC-LAN-B8J
T-2A
26
RVGA-LAN-HCL
T-17A
15
SXEA-LAN-BB5
T-2A
164
RSFC-LAN-BB4
T-2A
164
RVGA-LAN-HCM
T-17A
15
SXEA-LAN-BBW
T-2A
164
RSFC-LAN-BB5
T-2A
164
RVIA-LAN-KC6
T-19A
15
SXEA-LAN-BCD
T-2A
22
RSFC-LAN-BBW
T-2A
164
RVIA-LAN-KCE
T-19A
15
SXEA-LAN-BCI
T-2A
22
RSFC-LAN-BCD
T-2A
22
RVIA-LAN-KCF
T-19A
15
SXEA-LAN-BCJ
T-2A
22
RSFC-LAN-BCI
T-2A
22
RVIA-LAN-KCN
T-19A
15
SXEA-LAN-BCL
T-2A
22
RSFC-LAN-BCJ
T-2A
22
RVIA-LAN-XZZ
T-19A
16
SXEA-LAN-BJ4
T-2A
175
RSFC-LAN-BCL
T-2A
22
RVIA-LAN-Z8Z
T-19A
16
SXEA-LAN-BJ5
T-2A
175
RSFC-LAN-BJ4
T-2A
175
RVCA-LAN-EBC
T-11A
147
SXEA-LAN-BJW
T-2A
175
RSFC-LAN-BJ5
T-2A
175
SCCA-LAN-ECB
T-11A
30
X2CD-LAN-CA
156
RSFC-LAN-BJW
T-2A
175
SCCA-LAN-ECC
T-11A
30
X2DD-LAN-CA
172
RSHC-LAN-BK4
T-17A
185
SCCA-LAN-ECH
T-11A
30
X2DD-LAN-HA
172
RSHC-LAN-BK5
T-17A
185
SCCA-LAN-ECI
T-11A
30
X3DD-LAN-CA
172
RSHC-LAN-BK6
T-17A
185
SCCA-LAN-ECJ
T-11A
30
X3DD-LAN-HA
172
RSHC-LAN-BK7
T-17A
185
SCEA-LAN-BCB
T-2A
30
X4CD-LAN-CA
157
RSHC-LAN-BKW
T-17A
185
SCEA-LAN-BCC
T-2A
30
X4DD-LAN-CA
172
RSHC-LAN-H6E
T-17A
25
SCEA-LAN-BCD
T-2A
30
X4DD-LAN-HA
172
RSHC-LAN-H6F
T-17A
25
SCEA-LAN-BCH
T-2A
30
X6DD-LAN-CA
172
US Selected Assemblies Catalogue #999-901-192
274
Model Code Index
ASSEMBLIES
Page
Model Code
X6DD-LAN-HA
Model Code
Cavity
Page
172
YCJD-L*N-GR
Model Code
Cavity
206
YDJC-LHN-AN
227
XRCA-LAN-*A
17
YCJD-L*N-HR
206
YDJC-LHN-AS
227
XRCA-LAN-*B
17
YCJE-L*N-AR
210
YFCG-XHN-AA
158
XRCA-LAN-*C
17
YCJE-L*N-GR
210
YFCJ-XHN-AA
158
XRCA-LAN-*I
17
YCJE-L*N-HR
210
YFFE-XHN-AB
192
XRCA-LAN-*J
17
YCJG-L*N-AR
212
YFFF-XHN-AB
192
XRCD-LAN-CA
147
YCJG-L*N-GR
212
YFIA-XHN-CA
202
XRCD-LAN-HA
147
YCJG-L*N-HR
212
YFIB-XHN-CA
202
XRDB-LCN-AL
218
YCJH-L*N-AR
208
YNAA-LDN-AA
158
XRDC-LNN-AK
214
YCJH-L*N-GR
208
YRDR-LAN-LA
138
XRDC-LNN-AL
214
YCJH-L*N-HR
208
YRDR-LAN-LB
138
XREA-LAN-*A
17
YDCA-LHN-AA
158
YRDR-LAN-LC
138
XREA-LAN-*B
17
YDCC-LHN-AC
224
YRDR-LAN-LI
138
XREA-LAN-*C
17
YDCC-LHN-AK
224
YRDR-LAN-LJ
138
XREA-LAN-*D
17
YDCD-LHN-AC
224
YRDR-LAN-LK
138
XREA-LAN-*J
17
YDCD-LHN-AK
224
YREM-LAN-LC
138
XREA-LAN-*L
17
YDEC-LHN-AD
225
YREM-LAN-LD
138
XRED-LAN-CA
163
YDEC-LHN-AL
225
YREM-LAN-LK
138
XRED-LAN-HA
163
YDED-LHN-AD
225
YREM-LAN-LL
138
XRFB-LCN-A4
219
YDED-LHN-AL
225
YRFF-LAN-LD
138
XRFB-LCN-AP
219
YDFE-LHN-AB
192
YRFF-LAN-LE
138
XRFC-LNN-A4
214
YDFG-LHN-AB
192
YRFF-LAN-LF
138
XRGA-LAN-*P
18
YDGC-LHN-AD
226
YRFF-LAN-LL
138
XRHB-LCN-A5
220
YDGC-LHN-AE
226
YRFF-LAN-LM
138
XRHB-LCN-AQ
220
YDGC-LHN-AF
226
ZJR
159
XRHC-LNN-AM
215
YDGC-LHN-AL
226
ZPT
159
XRIA-LAN-*S
18
YDGC-LHN-AM
226
ZUO
159
XRJB-LCN-AR
221
YDGD-LHN-AD
226
ZVT
159
XRJB-LCN-AS
221
YDGD-LHN-AE
226
ZWV
159
XRJC-LNN-A6
216
YDGD-LHN-AF
226
ZWW
159
XRJC-LNN-AM
215
YDGD-LHN-AL
226
XRJC-LNN-AR
216
YDGD-LHN-AM
226
XRJC-LNN-AS
217
YDGE-LHN-CA
202
YCJD-L*N-AR
206
YDGF-LHN-CA
202
275
Cavity
Page
US Selected Assemblies Catalogue #999-901-192
Warranty
WARRANTY INFORMATION,
PERFORMANCE ASSURANCE,
AND APPLICATION LIMITATIONS
Caution
Sun Hydraulics Corporation manufactures a variety of
cartridge valves that will fit into the same Sun cavity. Each
cartridge is marked with a seven-digit part identification code
and a four-digit date code, stamped on the hex surfaces.
Designers and users of Sun components are advised that
physical interchangeability of cartridges does not
necessarily mean functional interchangeability. When
replacing any Sun cartridges, users should first check with the
manufacturer's service literature, their local Sun distributor, or
the Sun factory before making any part substitutions.
NOTE: To avoid serious injury, the manufacturer's service
manual must be consulted before working on any hydraulic
system.
Limited Warranty
Sun Hydraulics Corporation warrants its products free
from defects in material, workmanship, and design for a period
of three years after installation, provided the installation date is
less than one year after manufacture. “O-rings” and seals are
specifically exempted from this warranty. In no instance is
there any warranty of fitness for a particular use and Sun
Hydraulics Corporation cannot and does not accept
responsibility of any type for any of its products that have been
subjected to improper installation, improper application,
negligence, tampering, or abuse, or which have been repaired or
altered outside of the Sun Hydraulics factory. Sun Hydraulics
Corporation’s liability under this warranty shall extend only to
replacement or correction, f.o.b. our factory, of any defective
part or product determined by inspection as not conforming to
this warranty. We make no other warranties, expressed or
implied, and are not responsible for any consequential damages
resulting from use by any buyer or user, our liability being
limited to the value of product sold or obligation to replace a
defective part.
Performance Assurance
All Sun cartridges are individually tested at the factory and
preset to specific pressure or flow settings where indicated in
this catalog. However, as the actual performance of buyers'
equipment cannot be reproduced in Sun's testing laboratory,
assurance of suitability of all Sun products in the buyer's
application is the responsibility of the buyer. This is typically
accomplished by the manufacture of a prototype followed by a
test or qualification program on the part of the buyer.
Application Limitations
Sun's product designs and manufacturing facilities have
been specifically developed to provide products for
commercial, industrial and mobile hydraulic applications and
Sun's products are only warranted for this type of use. Sun's
distributors are not authorized to approve the use of Sun
products in any of the following applications:
• Any product that comes under the Federal Highway
Safety Act, namely steering or braking systems for
passenger-carrying vehicles or on-highway trucks.
US Selected Assemblies Catalogue #999-901-192
276
•
•
•
•
Aircraft or space vehicles.
Ordnance equipment.
Life support equipment.
Any end product that, when sold, comes under the U.S.
Nuclear Regulatory Commission rules and regulations.
Specific written approval for any application of Sun
products in any of the above named applications should be
obtained from Sun Hydraulics Corporation. Consultation with
Sun distributors or factory engineers is advised in unusual
situations where applicability is questionable.