Safety controller unit
Version 1.0 Safety controller unit Compact design 463111B2 / 463114B2 +PLd in acc. with EN ISO 13849-1 / SILCL2 in acc. with EN IEC 62061 +Two sensors can be directly connected + For sensors with 2-N.O. system +Space-saving design for tight installation spaces +Up to 16 sensors can be connected via an external interface + LED status display +Automatic start or manual start via start push button Use Types 463111B2 and 463114B2 are used for evaluating the signals from safety sensors. All elobau sensors with a 2-N.O. system can be connected to the unit. This unit can be used in any machine safety application requiring SIL 2, PL d. Due to its compact design, the control unit is perfectly suited for installation into small cabinets and machine housings. Variants Types 463111B2 and 463114B2 differ in respect to their operating voltages of 24 V DC or 230 V AC. The relevant corresponding technical documents will be supplied with the product. Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your specific product prior to any use. elobau reserves the right to change technical data and documentation without notice. elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | +49 (0) 7561 970-0 +49 (0) 7561 970-100 | www.elobau.com 463111 / 114B2 – Version 1.0 Page 1 of 7 Version Mechanical assembly Installation dimensions Housing 94 x 75 x 25 mm Installation On DIN rail TH35 acc. to DIN EN 60715 Key mechanical data Technology Control unit for 2 - 16 2-N.O. sensors* Material PA (polyamide) Weight 463111B2: approx. 120 g 463114B2: approx. 195 g Operating temperature range 0°C to +55°C Storage temperature -25°C to +85°C Housing protection class IP40 EN 60529 Housing color Black * 2 sensors can be directly connected, and up to 16 via an additional interface The relevant corresponding technical documents will be supplied with the product. Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your specific product prior to any use. elobau reserves the right to change technical data and documentation without notice. elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | +49 (0) 7561 970-0 +49 (0) 7561 970-100 | www.elobau.com 463111 / 114B2 – Version 1.0 Page 2 of 7 Version Approvals and safety-relevant technical specifications Safety-relevant technical specifications SILCL 2 (EN IEC 62061) PLd (EN ISO 13849-1) Category 3 (EN ISO 13849-1) PFHD 463111B2: 1.02e -8 1 / h PFHD 463114B2: 9.69e -9 1 / h Service life: 20 years Approvals TÜV / ETL (planned for 463111B2) Key electrical data 463111B2 463114B2 Operating voltage 24 V DC ±10% 230 V AC ±10% Current consumption Max. 100 mA Max. 25 mA Status indication 3x LED Monitoring External contactor / start push button Operating time 3s Safety output Switching voltage 250 V AC / 30 V DC Switching current 3A Switching power 750 VA / 90 W The relevant corresponding technical documents will be supplied with the product. Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your specific product prior to any use. elobau reserves the right to change technical data and documentation without notice. elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | +49 (0) 7561 970-0 +49 (0) 7561 970-100 | www.elobau.com 463111 / 114B2 – Version 1.0 Page 3 of 7 Version Wiring 463111B2 Logic Logic Input Input 6 7 8 9 10 11 12 13 24 V DC K1 K2 Output Output (+) Sensor 11 (-) (+) Sensor Sensor 22 (-) 5 External External contactor / contactor/ Start Start 1 + 2 - Safety Safety 3 & 4 Ready Ready K2 K1 463114B2 Logic Input Logic Input 6 7 8 9 10 11 12 13 230 V AC K1 K2 Output Output (+) Sensor Sensor 11 (-) (+) Sensor Sensor 22 (-) 5 External External contactor / contactor/ Start Start 1 + 2 - Ready Ready Safety Safety 3 & 4 K2 K1 Illustration in de-energized state. Sensor(s) not actuated. The relevant corresponding technical documents will be supplied with the product. Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your specific product prior to any use. elobau reserves the right to change technical data and documentation without notice. elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | +49 (0) 7561 970-0 +49 (0) 7561 970-100 | www.elobau.com Input / 114B2 – Version 1.0 Page 4 of 7 Version Connection type Terminal block 0.08 - 2.5 mm2 Terminals 1 + 2: UB Terminals 3 + 4: safety output Terminal 5: external contactor / start push button Terminals 6 – 9: sensor 1 Terminals 10 - 13: sensor 2 The integrated LEDs signal if the operating voltage is switched on and which sensors are connected. After switching on the operating voltage, an automatic or monitored start is possible if all sensors are operating properly. Two safety sensors can be connected directly to the control unit. When using the following elobau interfaces, the monitoring can be extended to up to 16 sensors: 363V99 363.97 The relevant corresponding technical documents will be supplied with the product. Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your specific product prior to any use. elobau reserves the right to change technical data and documentation without notice. elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | +49 (0) 7561 970-0 +49 (0) 7561 970-100 | www.elobau.com Input / 114B2 – Version 1.0 Page 5 of 7 Version Fax: +49 (0) 7561 970-100 E-Mail: [email protected] Your product Specifi cationsenquiry of your safety controller unit Version 463111B2 (UB = 24 V DC) Quantity 463114B2 (UB = 230 V AC) Batch size Name / first name Company Address Postal code / town Country E-Mail Notes, questions, other The relevant corresponding technical documents will be supplied with the product. Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your specific product prior to any use. elobau reserves the right to change technical data and documentation without notice. elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | +49 (0) 7561 970-0 +49 (0) 7561 970-100 | www.elobau.com Input / 114B2 – Version 1.0 Page 6 of 7 Version Fax: +49 (0) 7561 970-100 E-Mail: [email protected] Your product enquiry Quantity Batch size Name / first name Company Address Postal code / town Country E-Mail Notes, questions, other The relevant corresponding technical documents will be supplied with the product. Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your specific product prior to any use. elobau reserves the right to change technical data and documentation without notice. elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | +49 (0) 7561 970-0 +49 (0) 7561 970-100 | www.elobau.com Input / 114B2 – Version 1.0 Page 7 of 7
Similar documents
Ac ServO Sürücüler SiGMA-5 SEriSi - Yaskawa
Sigma-5 serisi, genel standartlara uygun olarak tasarlanmıştır. Haberleşme modülünü servopack'ler ve motorlarla birlikte kullanmak için takıp çalıştırmak yeterlidir. Bu hem mevcut işletmelerde ve m...
More information