MC 380H TECHNICAL INSTALLATION MANUAL
Transcription
MC 380H TECHNICAL INSTALLATION MANUAL
MC 380H TECHNICAL INSTALLATION MANUAL CODE : A6000200N-400D MC 380H HIGH VACUUM LENS COATING MACHINE TECHNICAL INSTALLATION MANUAL GENERAL INDEX REFERENCE DESCRIPTION INSTALLATION / GENERAL CONNECTIONS - PREPARATION PROCEDURE FOR THE INSTALLATION - LAYOUT - POWER DISTRIBUTOR (WIRING DIAGRAM) - GROUND TEST DIAGRAM MC 380H TECHNICAL DATA: - H.V. BOX COATER - GAS TECHNICAL DATA BOX COATER SYSTEM MC 380H / MC 380 KIT PREPARATION PROCEDURE FOR THE INSTALLATION Water circuit connections For the tap water supply provide for a pipe line with 2 taps of ¾”G [(3/4” fpt USA) — female thread)] in order to feed: • Water deionizer and T10 • Box coater. The water discharges coming from different components are as follows (5 pipe lines): a) b) c) no. 3 water pipe lines from the cleaning system; 2 of them for water exhaust with a PVC flexible hose (int. dia. 25 mm/ext. dia. 32 mm); 1 of them for detergent exhaust, still made of PVC but with different diameters (int. dia. 16 mm/ext. dia. 22 mm). No. 1 pipe line from the deionizer with a PVC flexible hose (int. dia. 16 mm/ext. dia. 22 mm). No. 1 pipe line from the box coater with a PVC flexible hose (int. dia. 25 mm/ext. dia. 32 mm). IMPORTANT:the main discharge must be close to the floor (at a distance of max. 300 mm) in order to allow a better drainage coming from the different units. The requested minimal dimension is a pipe with a 3”G internal diameter. Modem connection Provide for a direct phone line (that is by-passing your eventual switchboard). Electrical wiring connection See drawing regarding “Power Distributor”. Compressed air connection For the compressed air line you must provide for a plastic hose (int. dia. 8 mm/est. dia. 10 mm). This will be connected to the “COMPRESSED AIR DRYING UNIT” which will feed the “BOX COATER” and the “IONIZED AIR SYSTEM”. Plant dimensions Please verify that the dimensions of your entry door as well as of your working area are consistent with the dimensions indicated on our suggested lay out and on the technical data sheet named “Dimensions of SATISLOH MC 380H”. Chiller water circuit connection (on request) For city water supply you have to provide for a line with ¾”G female thread. REMARKS: for the above mentioned connections please refer to the standard lay out as per our drawing no. B6000200N-820L or to the personalized lay out requested by the customer. Technical details are subject to change without prior notice FILE: 380H.DOC REV. A-0305 SATIS BOX COATER SYSTEM SATIS MC 380H / MC380 KIT PREPARAZIONE AREA PER L’INSTALLAZIONE Collegamenti circuito acqua Per l’erogazione dell’acqua di rete dovete predisporre una linea con 2 rubinetti da ¾”G femmina, di cui uno destinato all’unità di lavaggio (deionizzatore e T10) e l’altro all’impianto di deposizione. Gli scarichi dell’acqua provenienti dagli utilizzi sono 5, così suddivisi: a) b) c) no. 3 linee provenienti dall’unità di lavaggio, due delle quali per lo scarico dell’acqua, con un tubo flessibile in PVC (diam. int. 25 mm/est. 32 mm) e l’altro per lo scarico dei detergenti, con lo stesso tipo di tubo, ma con diametri diversi (int. 16 mm/est. 22 mm). No. 1 linea proveniente dal deionizzatore, con un tubo flessibile in PVC (diam. int. 16 mm/est. 22 mm). No. 1 linea proveniente dall’impianto di deposizione, con un tubo flessibile in PVC (diam. int. 25 mm/est. 32 mm). IMPORTANTE:lo scarico generale che dovete installare deve essere posto vicino al pavimento (ad una distanza di max. 300 mm) in modo tale da permettere un miglior drenaggio delle macchine. La dimensione minima richiesta è un tubo avente il diametro interno di 3”G. Collegamento modem Preghiamo predisporre una linea telefonica diretta (vale a dire senza passare dal Vs. eventuale centralino). Collegamento circuito elettrico Vedi disegno “Power Distributor”. Collegamento aria compressa Predisporre una linea di aria compressa con un raccordo per tubo in plastica del diam. int. di 8 mm ed est. di 10 mm. Questa linea sarà collegata al “COMPRESSED AIR DRYING UNIT” che, a sua volta, alimenterà l’impianto MC380H (“BOX COATER” e “IONIZED AIR SYSTEM”). Dimensioni impianto Preghiamo verificare che le dimensioni della Vs. porta d’ingresso nonché dell’area di lavoro siano compatibili con le dimensioni indicate sul lay out da noi consigliato e sul foglio informativo chiamato “Dimensioni SATISLOH MC 380H”. Collegamento circuito acqua del “chiller” (su richiesta) Per l’erogazione dell’acqua di rete dovete predisporre una linea con 1 rubinetto da ¾”G femmina. N.B.: per i punti di collegamento sopraccitati fare riferimento al lay out standard di cui al dis. B6000200N-820L oppure al lay out personalizzato richiesto dal cliente. I dati tecnici sono soggetti a variazioni senza preavviso FILE: 380H.DOC REV. A-0305 Satisloh AG Neuhofstrasse 12 CH-6340 Baar Phone +41 (0)41 766 16 16 Fax +41 (0)41 766 16 10 www.satisloh.com [email protected] Summary of Installation requirements for MC-380-H Electrical Connection* Equipment ERC 504 Air compressor 3x400 V 50 or 60 Hz 15 kVA; average cosφ = 0,86 35 A Fuse or breaker 3x400 V 50 Hz 3x460 V 60 Hz 8,9 kVA 7,3 kVA Typ; cosφ =0.78 15A Fuse or breaker 400 V 18A Fuse or breaker 460 V 3x400 V 50 Hz 3x460 V 60 Hz 8,8 kVA; typ. cosφ = 0.8 25 A Fuse or breaker 3x400V 50 or 60Hz 3kW 6A 3x400V 50 or 60Hz 7.5kW 16A 230V 50 or 60Hz 120W 1A 230V 50 or 60Hz 0.6kW 4A 230V 50 or 60Hz 2kW 10A 230V 50 or 60Hz 3kW 16A 230V 50 or 60Hz 0.6kW 4A 3x400V 50Hz 5.2Kw 9.5A 3x400V 50Hz 8kW 17,7A 3x400V 50 or 60Hz 1.5kW 4A 230V 50 or 60Hz 0.6kW 2,6A 230V 50 or 60Hz 0.35kW 2A 3x400V 50 or 60Hz 4kW 10A SPL 012 Air Drying unit 230V 50Hz 0.25kW 2A MC-380-H Box coater CC-10-S Cascade cooler CC-5-S Cascade cooler T-10-Ecoline-2 Cleaning unit RWH 40 Rinsing water heater SAT 100 Projector CV 400 Oven CV 400D Oven ES 26 Ionized air FB 260 Flow box GCC 9 Chiller GCC 15/T Chiller tropic SA 20 Sandblasting SW12 AR Lens ring cleanig CF 90 Suction Hood Gas Compressed Air Water Air exhaust Comment 1 tank O2 1 tank Ar inlet tube O.D. 10 mm inlet tube 1/2" G male outlet tube 1/2" G male 65 m3/h rotary pump outlet 1 tube O.D. 40 mm behind the plant _ _ included in the plant _ _ _ included in the plant _ _ _ inlet tube 1/2" G female outlet to see T.I.M. city water 225 L/h 300 m3/h _ _ inlet tube 1/2" G male outlet tube 1/2" G male _ _ _ _ _ _ _ _ _ _ _ _ _ _ inlet tube O.D. 10 mm _ _ _ _ _ _ _ _ inlet tube 1/2" G male 4000 m3/h _ _ inlet tube 1/2" G male 6000 m3/h _ _ _ _ _ _ _ _ _ inlet tube O.D. 12 mm inlet tube 1/2" G male _ _ inlet tube I.D. 16 mm condensed water drain _ _ inlet tube I.D. 16 mm outlet tbe O.D. 10 mm for plant condensed water drain _ outlet 1 tube O.D. 100 mm behind the plant Notes: For other technical details see the T.I.M. (Technical Installation Manual) *: For all other voltage than 400 V and 230V or 60 Hz, if not specified, refer to T.I.M. (Technical Installation Manual). Besides all the power supply cables must have PE (yellow – green ground) wire, neutral wire couldn’t be necessary in some application please refer to T. I. M. Data sheet Technical details are subject to change without prior notice Rev.B-943 MC380-H Summary of installation requirements (B943).doc Appendix A – Suggested earth system and earth leakage breaker In order to have the optimal operation of the electronic equipment, Satisloh MC260/350/360/360R/380/380R/380H/380Kit plants must be grounded to an earth system with resistance ≤ 3Ω and sized according to the plant power supply line. To reduce high frequency electrical noise to the control equipment Satisloh suggest realizing an earth system complying with general rules and with the following preferred implementations, see Fig 1. This configuration can be used with several plants installed on the same room as long as each connection length to the rods is ≤ 20 m. Fig. 1 VIETATA LA RIPRODUZIONE. SENZA AUTORIZZAZIONE SCRITTA DELLA satisloh Italy COPYRIGHT BY satisloh Italy S.p.A. ALL RIGHTS RESERVED S.p.A. Pag. 1-2 Earth leakage breaker In order to protect against electric shock, the standard distribution box, supplied with the plant, include a 500 mA Residual Current Device (earth leakage breaker). For proper operation no other similar protection devices with lower value is allowed on the plant power supply line. Additional notes on grounding circuits The Satis MC series plants use two grounding connections: - from the power supply line (to comply with the Standard requirement) - direct connection to the ground rod (to reduce high frequency electrical noise due to E.B.G.) If other machines (not Satisloh with similar or greater power requirement) are installed on the same power supply line and share a common ground path, in case of fault the current can go trough the direct connection (of the Satisloh plant) to the rod. Since this current is coming from an external fault no protection can be provided by the earth leakage breaker and a danger condition can be generated. To avoid these situations one of these solutions can be used: - use a local earth leakage breaker for each plant line - avoid sharing ground line between different plants ATTENTION PLEASE If for any reason the devices are not supplied trough our distribution box (without leakage breaker) a general earth leakage breaker with 500 mA (phases and neutral) must be provided on the supply line. In the “GROUND RESISTANCE TEST DIAGRAM” is indicated how to measure the ground resistance. VIETATA LA RIPRODUZIONE. SENZA AUTORIZZAZIONE SCRITTA DELLA satisloh Italy COPYRIGHT BY satisloh Italy S.p.A. ALL RIGHTS RESERVED S.p.A. Pag. 2-2 Satisloh AG Neuhofstrasse 12 CH-6340 Baar Phone +41 (0)41 766 16 16 Fax +41 (0)41 766 16 10 www.satisloh.com [email protected] MC-380-H Technical data Typical system configuration (refer to MC-380-H dimensions and quotation) A B C D MC-380-H Box coater (including water thermo conditioner) CC-10-S Cascade cooler for Meissner trap (CC-5-S on request) GCC-9 Water chiller Transformer for box coater, cascade cooler, flow box, de-ionizer, cleaning unit, oven, ionized air, projector (for other voltage than 400 V) Box coater 15 kW cos ϕ 0.75 400 V (± 10%) 50/60 Hz (± 2%) ≤ 3 Ohm 5% 35 A Standard version 25 A Reduced power version (see note *) Rated power consumption Nominal rated voltage (3P + N + E) and rated frequency Grounding resistance Max. harmonic distortion Fuses or breaker at 400 V CC-10-S Cascade cooler ( CC-5-S on request) Rated power consumption Nominal rated voltage (3P + N + E) and rated frequency 8.9 kVA 400 V (± 10%) 50 Hz (± 2%) 460 V (± 10%) 60 Hz (± 2%) 25 A Fuses or breaker at 400 V GCC-9 Water chiller Rated power consumption Nominal rated voltage (3P + N + E) and rated frequency Fuses or breaker at 400 V Water temperature 4.5 kW (50 Hz) 4.93 kW (60 Hz) 400 V (± 10%) 50/60 Hz (± 2%) 9.5 A (50 Hz) 18 ÷ 20°C Coating room conditioning requirements Temperature Relative humidity Clean room 20 ÷ 25 C° 40 ÷ 55% Class 100.000 Box coater compressed air Pressure Consumption Typical gas for coating process Pressure Consumption Purity Transformer D (for other voltage than 400 V) 6/600 bar/kPa minimum 10 l/batch (typical) Oxygen 0.35/35 bar/kPa 3 60 cm /batch (typical) 99,995% (N45) Nominal power Argon 0.7/70 bar/kPa 30 cm3/batch (typical) 99,995% (N45) 45 kVA Weight approx. MC-380-H Box coater components • Vacuum chamber assembly (electrical cabinet included) • Water thermo conditioner • Preliminary vacuum pump CC-10-S Cascade cooler CC-5-S Cascade cooler (on request) GCC-9 Water chiller Transformer (for other voltage than 400 V) Note: 1320 kg 60 kg 73 kg 243 kg 408 kg 130 kg 320 kg This data sheet does not include any other peripheral equipment consumption. * Contact technical dept. in Satisloh Italy Data sheet Technical details are subject to change without prior notice Rev. D-947 Satisloh AG Neuhofstrasse 12 CH-6340 Baar Phone +41 (0)41 766 16 16 Fax +41 (0)41 766 16 10 www.satisloh.com [email protected] MC-380-H Major components Vacuum system Vacuum chamber volume with rotating substrate holder Preliminary vacuum pump (rotary pump) Turbomolecular pump Meissner trap End vacuum after 24 hours outgassing at 300°C 374 l 62 m3/h 1900 l/s 50000 l/s 1 E – 4 Pa Electron beam evaporation system Emission current High voltage output Crucible diameter Beam deflection 0.5 A max. 10 kV max. 133 mm 270°C Quartz film thickness measuring unit Quartz measuring head Frequency 1 6 MHz Plasma rod (optional) Voltage (output) Emission current 1500 V typical 250 mA typical Ion beam gun (optional) Gun type Anode current Anode voltage gridless 1 A max. 160 V max. Substrate heating systems available (depending on process) Bottom heater Top heater maximum temperature 150°C maximum temperature 300°C Substrate holders systems available Three-sector dome Flip-over external diameter 710 mm external diameter max. 700 mm Process control system type Type S-9380 (Industrial PC – IBM compat.) Water thermo conditioner (included) Pressure Water flow (closed circuit) Data sheet 3/300 bar/kPa 1200 l/h approx. Technical details are subject to change without prior notice Rev. A-415 Satisloh AG Neuhofstrasse 12 CH-6340 Baar Phone +41 (0)41 766 16 16 Fax +41 (0)41 766 16 10 www.satisloh.com [email protected] MC-380-H Packing details Description Dimensions of wooden case (approx.) (W x D x H) Gross weight (approx.) MC-380-H 275 x 120 x 238 cm 1370 kg Std. spare parts, water thermo conditioner 210 x 150 x 167 cm 900 kg CC-10-S Cascade cooler 81 x 76 x 187 cm 360 kg CC-5-S Cascade cooler (on request) 120 x 90 x 208 cm 600 kg GCC-9 Water chiller 87 x 85 x 166 cm 237 kg GCC-15T Water chiller, Tropical version 130 x 92 x 198 cm 360 kg Transformer (for other voltage than 400 V) 95 x 95 x 125 cm 411 kg CV-400-D Degassing oven (for Dome) 115 x 110 x 110 cm 212 kg CV-400 Degassing oven (for F/O) 80 x 80 x 112 cm 120 kg T-10 Ultrasonic cleaning unit 169 x 125 x 160 cm 425 kg LMRE-7 Water de-ionizer Additional equipment for LMRE-7 110 x 110 x 190 cm 77 x 67 x 65 cm 380 kg 114 kg FB-260 Flow box (for MC-380-D Coating lab) 240 x 110 x 207 cm 460 kg Table for FB-260 Flow box (for MC-380-H Coating lab) 235 x 95 x 115 cm 180 kg FLV-72 Flow box 208 x 116 x 255 cm 633 kg SA-20 Sand blasting unit 150 x 140 x 207 cm 490 kg Data sheet Technical details are subject to change without prior notice Rev. C-943 Satisloh AG Neuhofstrasse 12 CH-6340 Baar Phone +41 (0)41 766 16 16 Fax +41 (0)41 766 16 10 www.satisloh.com [email protected] MC-380-H Dimensions A B C D ** MC-380-H Box coater (including water thermo conditioner) CC-5-S Cascade cooler GCC-9 Water chiller Transformer for box coater, cascade cooler, flow box, de-ionizer, cleaning unit, oven, ionized air, Light projector (for other voltage than 400 V) Dimensions with wheels but without top cover Dome version 2200 mm Flip-over version 2170 mm Data sheet Technical details are subject to change without prior notice REV. B-817 POSIZIONAMENTO IMPIANTO Una volta in posizione, togliere le ruote e regolare i piedini fino alla messa in bolla. PLANT POSITIONING After positioning adjust the feet to level the plant off. STELLUNG DER ANLAGE Die anlage in die Betriebstellung schieben. Nachdem die Anlage in der richtigen stellung gefahren worden ist, die raeder mit Hilfe eines Hebels, siehe oben) abnehmen und die Fuesse justieren, um die Anlage auszurichten. h min. 30mm Prima della regolazione Before level adjusting Vor der justierung h max. 40mm Dopo la regolazione After level adjusting Nach der justierung 1500mm~ 2 1 Cylinder Ø : 250mm approx. Cylinder height : 1,5m approx. Ø 250mm~ Vietata la riproduzione senza autorizzazione della 1) OXYGEN CYLINDER FOR ION SOURCE AND REACTIVE EVAPORATION - purity : - content : - pressure : 99,995% (N45) 7,5 cu.m. approx. 150 ÷ 200 bar 2) PRESSURE REDUCER - outlet pressure - inlet pressure : : 0 ÷ 2 bar 10 ÷ 200 bar NOTE: FILE : OTI_91_04_09.CDR REV. NUMERO C.O. DATA FIRMA CONTR. DEVIAZIONE SU QUOTE SENZA TOLL. >0 a 50 + - 0.1 >50 a 250 + - 0.2 >250 a 800 >800 a 2000 + - 0.4 + - 0.8 Ra N12 N11 N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 : : : : : : : : : : : : DIM/mm (um) 50 25 12.5 6.3 3.2 1.6 0.8 0.4 0.2 0.1 .05 .025 FIRMA E. Tunesi DESCRIZIONE CONTR.C. Minnaja DATA 07.04.2008 DISEGNO Nr. OXYGEN CYLINDER FOR ION SOURCE MAT. TT. SMUSSI: FIN. O.T.I. 91.04.09 REV. PAG. B 1/1 1500mm~ 2 1 Cylinder Ø : 250mm approx. Cylinder height : 1,5m approx. Ø 250mm~ 1) ARGON CYLINDER FOR ION SOURCE Vietata la riproduzione senza autorizzazione della - purity : - content : - pressure : 99,995% (N45) 10 cu.m. approx. 150 ÷ 200 bar 2) PRESSURE REDUCER - outlet pressure - inlet pressure : : 0 ÷ 2 bar 10 ÷ 200 bar NOTE: FILE : ATI_91_04_09.CDR REV. NUMERO C.O. DATA FIRMA CONTR. DEVIAZIONE SU QUOTE SENZA TOLL. >0 a 50 + - 0.1 >50 a 250 + - 0.2 >250 a 800 >800 a 2000 + - 0.4 + - 0.8 Ra N12 N11 N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 : : : : : : : : : : : : DIM/mm (um) 50 25 12.5 6.3 3.2 1.6 0.8 0.4 0.2 0.1 .05 .025 FIRMA E. Tunesi DESCRIZIONE CONTR.C. Minnaja DATA 07.04.2008 DISEGNO Nr. ARGON CYLINDER FOR ION SOURCE MAT. TT. SMUSSI: FIN. A.T.I. 91.04.09 REV. PAG. B 1/1