Cam switches R series
Transcription
Cam switches R series
www.breter.it Cam switches R series from 16A to 315A PROFILE BRETER has been established in the fifties as a manufacturer of switches for industrial applications and achieved a key specialist role in the market of electromechanical low-voltage industrial controls, especially due to its expertise on custom-designed products. Product quality has been Breter distinctive and prestigious way to be succesful through the years. Thanks to its development and constructive policies, today Breter's strength is a unit of 20.000 square meters, a specialists equipe, the leading position into the major international markets besides Italy and a wordwide distribution network. The Company works in Quality Warranty to ensure top quality levels, also confirmed by products conformity to UL/CSA and IEC/EN national and international regulations and a number of approvals. Breter faces the future with technological innovations applied to design systems, workshop, production and Quality Warranty structures. High innovative production organizations are based on automatic assembly lines and automatic injection plastic materials presses as well as advanced gears for quality control carried out on 100% of finished products. Engineering systems exploit CAD technology to develop new solutions and improve products quality and functionality. The Company Test Laboratory is equipped with gears and instruments suitable for electrical, mechanical and climatic high reliable tests both on prototypes and finished products. Breter complete range of standard and special versions for all power and control functions in electrical and electronic applications is typically used by OEM, panel builders and installers in the following fields: tools and industrial machines, automation, transports, off-shore, lifting equipment, energy production and distribution. The whole Breter range covers more than 4 thousands products out of the catalog in addition to an even higher number of custom-designed products; cam switches and switch disconnectors from 10A up to 630A and a complete line of push buttons, selector switches and pilot lights Ø 16 - 22 - 30 mm with plenty of choices as far as functions and outward solutions. Cam switches R SERIES Cam switches For rated current from 16A to 315A Wide range of electrical functions Special schemes available on request Type of fixing: front mounting, base mounting or central fixing Ø 22mm Actuator with screw fixture or central fixture Ø 22mm LEGENDA Black legend plate Grey legend plate Silver-grey legend plate Grey/black actuator Yellow/red actuator Key removable 1 General features The features and the use of the best standard of materials assure the quality, reliability and safety of breter cam-switches, as confirmed by the approvals granted by the most important international test houses. • Use for breaking, changing-over, making and starting of circuits with inductive or resistive electric loads; rated loads from 16A up to 315A • High resistance to mechanical stress and to tracking, dimensional stability. • Double break silver alloy contacts • Screw terminals for cables with/without cable terminal, of easy identification • Special electrical schemes available on request • Wide range of attachments to obtain many versions • Quality and reliability for the highest safety of operation on control circuits • Convenience and pratical use • Compliance with international specifications • Ip degree of protection according to IEC 529, CEI 70-1 • CEI/EN 60445 is the standard applies to the identification and marking of terminals of electrical equipment Typical applications of cam switches On-off switch Two-position switches used to connect and disconnet any electtical supply. They are used in a variety of power switchig applications like manual control of direct on-line motors and isolation of motor branch circuits. Changeover switch Three-position switches used in power applications to change between alternate electrical supplies. Changeover switches are typically used to switch the power supply from the primary source to a stand-by generator or emergency supply in the event of a power outage. Step switch Multi-position switches used to connect a variety of loads to an electrical supply in a predeterminated logical sequence. A typical application would be temperature control of a heating oven or furnace. Reversing switch Three-position (Forward, Off,Reverse) switches used to manually control the direction of rotation of a motor. Operating the switch changes the wiring configutation to the motor to operate in the forward or reverse direction. Dahlander switch Three-position (1st speed, off, 2nd speed) switches used to select 2 different speeds of rotation of a motor. Operating the switch changes the wiring configutation and the number of poles of the motor (i.e. 4/2, 8/4, etc.). The second speed is always two times the first one. Star Delta switch (Wye-Delta) Three-position (Off, Wye, Delta) switches used to manually control the reduced voltage starting of a motor. Operating the switch changes the wiring configutation to the motor from a star configuration to a delta cofiguration once the person operating the conrtoller determines the motor is up to speed. Ammeter switch Multi-position switches used to connect one or more phases of the electrical supply to an ammeter, so that the current in each phase can be displayed on the ammeter. Voltmeter switch Multi-position switches used to connect two lines of the electrical supply system to a voltmeter, so that the voltage between lines (phase-to-phase or phase-to-neutral) can be displayed on the voltmeter. Utilization categories To choose the most suitable and economic cam-switch in relation to the specific application it is necessary to compare the operating parameters of the unit to be controlled (voltage, current and power) with the camswitch performance. To make this comparison consult the IEC/EN 60947-1-3, 60947-5-1, 60204-1, specifications for the utilization categories. • AC-1 • AC-3 • AC-4 • AC-12 • AC-13 • AC-15 • AC-20 • AC-21 • AC-22 • AC-23 Non-inductive or slightly inductive loads, resistance furnaces Squirrel-cage motors: starting switching off motors during running Squirrel-cage motors: starting, plugging, inching Control of resistive loads and solid state loads with isolation by optocouplers Control of solid state loads with transformer isolation Control of a.c. electromagnetic loads Connecting and disconnecting under no-load condition Switching of resistive loads, including moderate overloads Switching of mixed resistive and inductive loads, including moderate overloads Switching of motor loads or other highly inductive loads • DC-1 Non-inductive or slightly inductive loads, resistance furnaces • DC-3 Shunt-motors, starting, plugging, inching, dynamic breaking of motors • DC-5 Series-motors, starting, plugging, inching, dynamic breaking of motors • DC-12 Control of resistive loads and solid state loads with isolation by optocouplers • DC-13 Control of d.c. electromagnets • DC-20 Connecting and disconnecting under no-load conditions • DC-21 Switching of resistive loads, including moderate overloads • DC-22 Switching of mixed resistive and inductive loads, including moderate overloads (e.g. shunt motors) • DC-23 Switching of highly inductive loads (e.g. series motors) Average full load currents of squirrel cage motors (alternate current 4 poles 1500 rpm) kW 0,06 0,09 0,12 0,18 0,25 0,37 0,55 0,75 1,10 1,50 2,20 3,00 4,00 5,50 7,50 11,00 15,00 18,50 22,00 30,00 37,00 45,00 55,00 75,00 90,00 110,00 Ampére 230V 0,41 0,62 0,83 1,16 1,43 1,90 2,67 3,45 4,75 6,05 8,45 11,70 15,00 19,50 25,50 37,00 50,00 60,50 72,50 97,50 117,00 141,00 173,00 229,00 272,00 333,00 400V 0,24 0,36 0,48 0,67 0,83 1,10 1,55 2,00 2,75 3,50 4,90 6,80 8,70 11,30 14,80 21,50 29,00 35,00 42,00 56,50 68,00 82,00 100,50 133,00 158,00 193,00 500V 0,19 0,29 0,38 0,54 0,66 0,88 1,24 1,60 2,20 2,80 3,90 5,40 7,00 9,10 11,90 17,00 23,00 28,00 33,50 45,00 54,50 64,00 80,00 106,00 126,00 153,00 690V 0,14 0,21 0,28 0,39 0,48 0,64 0,90 1,16 1,60 2,05 2,85 3,90 5,00 6,50 8,60 12,50 17,00 20,50 24,50 32,50 39,50 47,00 57,00 77,00 91,00 110,00 Series R Front mounting - On-off switches Standard handle Rated current Ie AC-21A (A) IP protection Dimensions mm x mm 0 16 40 3 poles 2 banks 4 poles 2 banks 48 14.01.11 14.02.11 14.03.11 14.04.11 90° 54 13.01.11 13.01.11C 1.01.11 13.02.11 13.02.11C 1.02.11 13.03.11 13.03.11C 1.03.11 13.04.11 13.04.11C 1.04.11 RE321751A RE401751A RE501751A RE801751A RE1251751A RE321752A RE401752A RE501752A RE801752A RE1251752A RE2501752A RE321753A RE401753A RE501753A RE801753A RE1251753A RE2501753A RE4001753A RE6301753A RE321754A RE401754A RE501754A RE801754A RE1251754A RE2501754A RE4001754A RE6301754A 1 72 25 32 40 50 75 120 200 250 315 2 poles 1 banks 64 88 90° 1 66 6 poles 3 banks 45° 1 0 20 1 pole 1 bank 0 130 RE321756A RE401756A RE501756A RE801756A RE1251756A RE2501756A Padlockable handle Rated current Ie AC-21A (A) 20 25 IP protection Rated current Ie AC-21A (A) 32 40 50 75 120 200 250 315 IP protection Dimensions mm x mm 90° 0 54 72 1 Dimensions mm x mm 67 1 66 90° 90 0 135 3 poles 2 banks 13.03.11-OZ 1.03.11-OZ 3 poles 2 banks RE321753G RE401753G RE501753G RE801753G RE1251753G RE2501753G RE4001753G RE6301753G 4 poles 2 banks 13.04.11-OZ 1.04.11-OZ 4 poles 2 banks RE321754G RE401754G RE501754G RE801754G RE1251754G RE2501754G RE4001754G RE6301754G 6 poles 3 banks RE321756G RE401756G RE501756G RE801756G RE1251756G RE2501756G 3 poles 2 banks 13.03.11-OM 1.03.11-OM 3 poles 2 banks RE321753N RE401753N RE501753N RE801753N RE1251753N RE2501753N RE4001753N RE6301753N 4 poles 2 banks 13.04.11-OM 1.04.11-OM 4 poles 2 banks RE321754N RE401754N RE501754N RE801754N RE1251754N RE2501754N RE4001754N RE6301754N 6 poles 3 banks RE321756N RE401756N RE501756N RE801756N RE1251756N RE2501756N Series R Base mounting - on-off switches Standard handle Rated current Ie AC-21A (A) 20 IP protection Dimensions mm x mm 90° 0 54 1 72 25 32 40 50 75 120 200 250 315 54 64 90° 1 66 88 0 130 3 poles 2 banks 13.03.11-3 13.03C-3 1.03.11-3 4 poles 2 banks 13.04.11-3 13.04C-3 1.04.11-3 6 poles 3 banks RA321753A RA401753A RA501753A RA801753A RA1251753A RA2501753A RA4001753A RA6301753A RA321754A RA401754A RA501754A RA801754A RA1251754A RA2501754A RA4001754A RA6301754A RA321756A RA401756A RA501756A RA801756A RA1251756A RA2501756A Padlockable handle Rated current Ie AC-21A (A) 20 25 IP protection Rated current Ie AC-21A (A) 32 40 50 75 120 200 250 315 IP protection Dimensions mm x mm 90° 0 55 72 1 Dimensions mm x mm 67 1 90° 90 0 66 135 3 poles 2 banks 13.03.11-SP 1.03.11-SP 3 poles 2 banks RA321753G RA401753G RA501753G RA801753G RA1251753G RA2501753G RA4001753G RA6301753G 4 poles 2 banks 13.04.11-SP 1.04.11-SP 4 poles 2 banks RA321754G RA401754G RA501754G RA801754G RA1251754G RA2501754G RA4001754G RA6301754G 6 poles 3 banks RA321756G RA401756G RA501756G RA801756G RA1251756G RA2501756G 3 poles 2 banks 13.03.11-OP 1.03.11-OP 3 poles 2 banks RA321753N RA401753N RA501753N RA801753N RA1251753N RA2501753N RA4001753N RA6301753N 4 poles 2 banks 13.04.11-OP 1.04.11-OP 4 poles 2 banks RA321754N RA401754N RA501754N RA801754N RA1251754N RA2501754N RA4001754N RA6301754N 6 poles 3 banks RA321756N RA401756N RA501756N RA801756N RA1251756N RA2501756N Series R On-off switches Central mounting Ø 22mm Rated current Ie AC-21A (A) IP protection Positions 90° 0 20 32 Control 1 66 90° 1 0 40 3 poles 2 banks 13.03.11-2M 13.03.11-2C 4 poles 2 banks 13.04.11-2M 13.04.11-2C 6 poles 3 banks handle key 2 poles 1 bank 13.02.11-2M 13.02.11-2C handle key handle key RC321752B RC321752DD RC401752B RC401752DD RC321753B RC321753DD RC401753B RC401753DD RC321754B RC321754DD RC401754B RC401754DD RC321756B RC321756DD RC401756B RC401756DD Thermoplastic enclosed switch, front actuator (130x95 h91mm) Rated current Ie AC-21A (A) 16 20 25 32 IP protection Dimensions mm x mm 90° 0 54 1 3 poles 4 poles 3 poles 4 poles 14.03.11-5S 13.03.11-5S 1.03.11-5S 2.03.11-5S 14.04.11-5S 13.04.11-5S 1.04.11-5S 2.04.11-5S 14.03.11-5R 13.03.11-5M 1.03.11-5M 2.03.11-5M 14.04.11-5R 13.04.11-5M 1.04.11-5M 2.04.11-5M Enclosed switch side lever Rated current Ie AC-21A (A) 20 25 32 50 75 120 IP protection 54 Fiber-glass filled enclosure 3 poles 13.03.11-5L 1.03.11-5L 2.03.11-5L 3.03.11-5L 4.03.11-5L 4 poles 13.04.11-5L 1.04.11-5L 2.04.11-5L 3.04.11-5L 4.04.11-5L IP protection 55 Metal enclosure 3 poles 13.03.11-4L 1.03.11-4L 2.03.11-4L 3.03.11-4L 4.03.11-4L 5.03.11-4L 4 poles 13.04.11-4L 1.04.11-4L 2.04.11-4L 3.04.11-4L 4.04.11-4L 5.04.11-4L Yellow cover and red handle Series R Changeover switches Front mounting - Standard handle Rated current Ie AC-21A (A) 16 20 25 32 40 50 75 120 200 250 315 IP protection Dimensions mm x mm 45° 0 1 2 40 48 54 72 45° 0 1 2 64 88 66 2 poles 2 banks 14.06.11 13.06.11 13.06.11C 1.06.11 RE323252A RE403252A RE503252A RE803252A RE1253252A 60° 0 1 1 pole 1 bank 14.05.11 13.05.11 13.05.11C 1.05.11 RE323251A RE403251A RE503251A 88RE803251A 2 130 3 poles 3 banks 14.07.11 13.07.11 13.07.11C 1.07.11 RE323253A RE403253A RE503253A RE803253A RE1253253A RE2503503A RE4003503A RE6303503A 4 poles 4 banks 14.45.11 13.45.11 13.45.11C 1.45.11 RE323254A RE403254A RE503254A RE803254A RE1253254A RE2503504A RE4003504A RE6303504A Front mounting - Padlockable handle Rated current Ie AC-21A (A) 20 25 32 40 50 75 120 IP protection Dimensions mm x mm 54 72 1 0 45° 67 2 66 90 135 3 poles 3 banks 13.07.11-OZ 1.07.11-OZ RE323253G RE403253G RE503253G RE803253G RE1253253G 4 poles 4 banks 13.45.11-OZ 1.45.11-OZ RE323254G RE403254G RE503254G RE803254G RE1253254G Base mounting - Padlockable handle - Doorlock Rated current Ie AC-21A (A) 20 25 32 40 50 75 120 IP protection Dimensions mm x mm 54 72 1 66 0 45° 2 67 90 135 3 poles 3 banks 13.07.11-SP 1.07.11-SP RA323253G RA403253G RA503253G RA803253G RA1253253G 4 poles 4 banks 13.45.11-SP 1.45.11-SP RA323254G RA403254G RA503254G RA803254G RA1253254G Series R Changeover switches Central mounting Ø 22mm Rated current Ie AC-21A (A) IP protection Positions 1 0 Control 45° 2 20 66 32 1 0 45° 2 40 handle key 3 poles 3 banks 13.07.11 - 2M 13.07.11 - 2C 4 poles 4 banks 13.45.11 - 2M 13.45.11 - 2C handle key handle key RC323253B RC323253DC RC403253B RC403253DC RC323254B RC323254DC RC403254B RC403254DC Enclosed switch side lever Rated current Ie AC-21A (A) 20 25 32 50 75 120 IP protection 55 Fiber-glass filled enclosure 3 poles 13.07.11-5L 1.07.11-5L 2.07.11-5L 3.07.11-5L 4.07.11-5L 4 poles 13.45.11-5L 1.45.11-5L 2.45.11-5L 3.45.11-5L 4.45.11-5L IP protection 54 Metal enclosure 3 poles 13.07.11-4L 1.07.11-4L 2.07.11-4L 3.07.11-4L 4.07.11-4L 5.07.11-4L 4 poles 13.45.11-4L 1.45.11-4L 2.45.11-4L 3.45.11-4L 4.45.11-4L 5.45.11-4L Series R Motor switches - Base mounting Standard handle REVERSING SWITCHES Rated Rated IP Dim. current power Pe protect. mmxmm Ie AC-21A (A) AC-23A (kW) 16 5,5 20 7,5 25 32 40 50 75 120 11 18,5 22 22 30 45 40 40 3 poles 1 2 3 banks 14.08.11 13.08.11 13.08.11C 1.08.11 RE327303A RE407303A RE507303A RE807303A RE1257303A 48 54 72 64 66 45° 0 88 130 DAHLANDER SWITCHES For single phase 45° For single phase motor with motor with 1 0 auxiliary M 0 M A winding A capacitor 3 banks 3 banks 13.32.11 13.32.11C 1.32.11 7,5 0 25 32 40 50 75 11 18,5 22 22 30 4 banks 120 45 72 88 Y 2 4 banks 7 banks 13.09.11 13.09.11C 1.09.11 RE327293A RE407293A RE507293A RE807293A RE1257293A 0 Y 2 2 13.11.11 13.11.11C 1.11.11 Y 5 banks 30°-60° 13.70.11 13.70.11C 1.70.11 RE327553A RE407553A RE507553A RE807553A reversing switch 0 Y 4 banks 60° 13.10.11 13.10.11C 1.10.11 RE327323A RE407323A RE507323A RE807323A 64 66 1 3 poles pole chan-45° ging and reversing 1 0 1 0 switch 0 SWITCHES 0 4 banks 54 40 45° 0 YY 45°-90° 20 2 13.37.11 13.37.11C 1.37.11 Y Rated Rated IP Dim. current power Pe protect. mmxmm Ie AC-21A (A) AC-23A (kW) 45° 3 poles Dahlander 45°-90° 13.54.11 13.54.11C 1.54.11 13.12.11 13.12.11C 1.12.11 Y 130 RE1257503A 0 60° Rated Rated IP Dim. current power Pe protect. mmxmm Ie AC-21A (A) AC-23A (kW) 54 20 7,5 40 25 11 72 For single phase motor with auxiliary winding 2 banks 13.29.11 13.29.11C 1.29.11 0 For remote control reverser M A M A 2 banks 13.30.11 13.30.11C 45° 0 45° Enclosed switch side lever Rated Rated IP current power Pe protect. Ie AC-21A (A) AC-23A (kW) 20 7,5 25 11 55 32 18,5 50 22 75 30 120 40 54 3 poles reversing switches 1 45° 13.08.11 - 5L 1.08.11 - 5L 2.08.11 - 5L 3.08.11-5L 4.08.11-5L 5.08.11-4L 0 2 3 poles Dahlander switches 45° 13.09.11 - 5L 1.09.11 - 5L 2.09.11 - 5L 3.09.11-5L 4.09.11-5L 5.09.11-4L 1 0 2 Y switches 0 45°-90° 13.10.11 - 5L 1.10.11 - 5L 2.10.11 - 5L 3.10.11 - 5L 4.10.11 - 5L 5.10.11 - 4L Y M A Series R On-off switches - Front mounting Rated current Ie AC-21A (A) IP Protection Positions 16 20 25 32 40 0 1 66 2 48 54 1 2 3 40 Dimensions mm x mm 45° 72 3 0 64 45° 0 1 20 25 32 40 40 4 1 66 2 2 3 54 45° 72 3 0 4 64 45° 0 1 20 25 32 40 40 5 4 1 66 2 2 3 54 45° 72 3 0 4 5 64 45° 0 1 20 40 16 20 40 45° 54 72 7 0 1 6 2 5 3 4 45° 48 54 72 6 5 4 1 20 40 45° 54 72 45° 54 72 30° 54 72 2 4 2 3 6 5 4 12 20 54 72 3 40 40 45° 3 1 20 45° 54 72 2 40 1 20 2 40 1 20 2 3 10 9 876 3 4 5 12 1 2 11 3 10 4 9 5 876 30° 1 pole 2 poles 3 poles 2 banks 14.57.11 13.57.11 13.57.11C 1.57.11 RE325261A RE405261A 2 banks 13.58.11 13.58.11C 1.58.11 RE325271A RE405271A 3 banks 13.59.11 13.59.11C 1.59.11 RE325281A RE405281A 3 banks 13.64.11 13.64.11C 4 banks 14.67.11 13.67.11 13.67.11C 3 banks 5 banks 13.60.11 13.60.11C 1.60.11 13.61.11 13.61.11C 1.61.11 4 banks 13.62.11 13.62.11C 1.62.11 6 banks 13.63.11 13.63.11C 1.63.11 6 banks 13.65.11 13.65.11C 9 banks 13.66.11 13.66.11C 2 banks 13.42.11 13.42.11C 3 banks 13.43.11 13.43.11C 4 banks 13.47.11 13.47.11C 6 banks 13.50.11 13.50.11C 6 banks 13.48.11 13.48.11C 9 banks 13.51.11 13.51.11C 1 bank 13.41.11 13.41.11C 2 banks 13.38.11 13.38.11C 2 banks 13.46.11 13.46.11C 3 banks 13.49.11 13.49.11C 5 banks 13.52.11 13.52.11C 6 banks 13.53.11 13.53.11C 4 banks 13.44.11 13.44.11C Series R Voltmeter / ammeter switches Front mounting VOLTMETER SWITCHES 3 phase Rated current Ie AC-21A (A) IP protection Dimensions mm x mm 0 RN 2 banks 0 20 48 54 40 72 25 for phase to phase for 3 phase for 1 phase of two 3-phase lines and 3 phase to phase and 3 phase to phase 0 RS 2 banks SN 45° 16 for 3 phase to phase TN 0 45° 4 banks RS ST S1T1 R1S1 TR 0 45° 14.16.11 13.16.11 13.16.11C 1.16.11 13.15.11 13.15.11C 1.15.11 0 RS T1R1 ST 3 banks 0 RN ST SN TR TR RN ST TN TR 45° 45° 14.18.11 13.18.11 13.18.11C 1.18.11 13.17.11 13.17.11C 0 RS 3 banks 14.19.11 13.19.11 13.19.11C Front mounting AMMETER SWITCHES For direct measure without break Rated current Ie AC-21A (A) IP protection Dimensions mm x mm 0 5 banks T 20 48 54 40 72 25 0 1 banks R S 90° 16 1 pole for 1 1 pole for 3 1 pole for 4 2 poles for 3 current transformer current transformer current transformers current transformers 0 1 3 banks 90° 13.14.11 13.14.11C 1.14.11 3 2 90° 13.20.11 13.20.11C 1 4 banks 1 4 5 banks 3 90° 14.22.11 13.22.11 13.22.11C 1.22.11 0 2 13.23.11 13.23.11C 3 1 2 90° 13.25.11 13.25.11C 1.25.11 DIN - RAIL mounting 45x54 45 64 80 VOLTMETER SWITCHES Rated current Ie AC-21A (A) IP protection Dimensions mm x mm for 3 phase to phase 0 RS ST 45° 20 40 54x45 13.16.11D 0 TR AMMETER SWITCHES for 3 phase and 3 phase to phase RS ST TR 45° 13.18.11D 0 RN SN 1 pole for 3 current transformers TN 90° 13.22.11D 0 3 1 2 Series R Accessories - handles and actuators Standard handle Black - lenght 40mm Red - lenght 40mm Black - lenght 50mm Black standard handle Lenght 35 mm Lenght 37,5mm Lenght 48mm Lenght 71mm Lenght 106 mm Red standard handle Lenght 37,5mm Lenght 48mm Lenght 71mm Lenght 106 mm Black handle Ø 30mm Red handle Ø 37mm Black handle Ø 37mm Black handle Ø 41mm IP40 IP65 Handle with locking device black red Series Code 13 13 13, 1 G1392N G1392R G1527N 13, 1 R32, R40 R32, R40 R50, R80 R125..R630 G3397N L2-G3154N L2-G3155N RG3518N RG3519N R32, R40 R32, R40 R50, R80 R125..R630 13, 1 13, 1 13, 1 13, 1 R32, R40 R32, R40 R32, R40 L2-G3154R L2-G3155R RG3518R RG3519R G2536N G2057R G2057N G3587N L2-G2851N L2-G2854N L2-G2864N L2-G2864R Black lever 13, 1 Orange lever 13, 1 Orange lever R32, R40 Black standard lever R125..R630 Red standard lever R125..R630 Actuator type N 72x72 mm yellow/red (for on - off switches with standard actuator) 13, 1 Actuator type N 67x67 mm yellow/red R32, R40 Actuator type N 90x90 mm yellow/red R50, R80 Actuator type N 135x135 mm yellow/red (with lever instead of handle) R125, R250 Actuator type G 72x72 mm grey/black for on-off switches (0-1) with standard actuator 13, 1 Actuator type G 72x72 mm grey/black for change over sw. (1-0-2) with standard actuator 13, 1 Actuator type G 67x67 mm grey/black for change over sw. (1-0-2) with standard actuator R32, R40 Actuator type G 67x67 mm grey/black for on-off switches (0-1) with standard actuator R32, R40 Actuator type G 90x90 mm grey/black R50, R80 Actuator type G 135x135 mm grey/black R125, R250 Yellow legend plate 72mm, red handle for on-off switches 13, 1 Yellow legend plate 54mm, red handle for on-off switches 13 G1529N G1529L G2865L RG3520N RG3520R G2391 LFS2-N-6-175 LFSR-N-8-175 LFSR-N-13-175 G3818 G2393 LFS2-G-6-325 LFS2-G-6-175 LFSR-G-8-175 LFSR-G-13-175 G2397 G2396 Actuator 54x54 mm neutral legend plate (without handle) Actuator 72x72 mm neutral legend plate (without handle) 13, 1 13, 1 G3455 G3456 Actuator with guard 70x70 mm (Complete of legend plate 0-1 Ø57 mm) 13, 1 G2433 Series R Accessories Series 13 13, 1 Code G1683 G1590 Central mounting Ø 22mm key operated removable in “0” position 13 G2389N Central mounting Ø 22mm key operated removable in “0” position R32, R40 G3805 + LFC2-DD-001 Central mounting Ø 22mm handle operated 13 G2390N Central mounting Ø 22mm handle operated R32, R40 G3805 + LFC2-B-001 Installation tool for tightening the central fixture nut (Ø 22mm) R32, R40 P3906 Panel hole adapter from Ø 30mm to Ø 22mm 13 G2326 Support for rear mounting 13 1 R50, R80 R125, R250 (max. 6 banks) R125, R250 (max. 6 banks) R400, R630 13, 1, R50, R80 G1720 RG1722 RG1724 RG1462 RG1474 RG1474 RG1761 Adapter plate for 4 fixing holes 68x68mm or 86x86mm Adapter plate for 4 fixing holes 68x68mm or 104x104mm R50, R80 R125..R630 REG3516 REG3517 DIN-rail mounting plate 13 G2535 Spacer for DIN-rail version (thickness 12,5 mm) 13 G2539 6,35 mm slip on terminal for screw terminals connection (M3,5) 13 1417 1 R32, R40 G2065 G3806 Gaskets to obtain IP54 degree of protection for basic version IP40 Extension supports for rear mounting Lenght: 35..171mm Device set to obtain a doorlock system from standard actuator Series R Accessories - Protections Terminal covers (3/4 poles) front mounting base mounting Series 13, 1 R32 R40 R50 R80 R125 Code P21853 RE32C4 RE40C4 RE50C4 RE80C4 RE125C4 13 1 R32 R40 R50 R80 R125 P21273 P20431 RA32C4 RA40C4 RA50C4 RA80C4 RA125C4 13 1 R32, R40 R50 R80 13 1 R32, R40 R50 R80 13 1 R32, R40 R50, R80 13 1 R32, R40 R50 R80 13 1 R32, R40 R50 13 1 R32, R40 R50 G1466 P10889 REG3180 REP10891 REP10892 G1466 P10889 REG3180 REP10891 REP10892 G1467 P10890 REG3181 REP10892 G1467 P10890 REG3181 REP10892 REP12792 G1468 P12481 REG3182 REP12792 G1468 P12481 REG3182 REP12792 Flexible shield 1 bank 2 banks 3 banks 4 banks 5 banks 6 banks Series R Accessories Series R32, R40 Front installation shaft Lenght 34 mm Termoplastc (standard) Lenght 34 mm Metal Lenght 34 mm Termoplastic (to turn position 90° anti-clockwise) Lenght 34 mm Termoplastic (to turn position 90° clockwise) Base installation shaft Lenght 44 mm Termoplastic (standard) Lenght 44 mm Metal Lenght 52 mm Termoplastic Lenght 52 mm Metal Lenght 57 mm Termoplastic Modular shaft extension 2 overlapping modules 24 mm (Max 4 modules - total lenght 96 mm) L2-G3380 L7-G3688 G3189 G3186 R32, R40 LA2-G2830 L7-G3687 LA2-G3194 L7-G3707 LA2-G3195 LA2-G2853 R32, R40 Metal shaft extension Lenght 110..235 mm Lenght 230..350 mm With yellow insert for on-off switches “0” h9 Insert for metal extension With red insert for on-off switches “0” h12 R32, R40 LA2-G3393 LA2-G3394 R32, R40 Grey insert to obtain a different start position “0” LA2-G3398 LA2-G3399 R32, R40 Clutch for doorlock “0” in position h12 “0” in position h9 R32, R40 Reducer for front installation shaft R32, R40 Termoplastic enclosure - front actuator with guard Code P25394 P26747 P3907 Series 13 banks 2 Code G3150 122x97 h 79mm 13 1 6 6 G2401 113x95 h 85mm 13 1 5 5 G2403 130x95 h 91mm 13 1 4 4 G2533 78x60 h 61mm IP54 Termoplastic enclosure - side operated lever IP55 Metal enclosure - side operated lever IP55 Termoplastic enclosure - front actuator IP54 Series R Accessories - Legend plates Central mounting Ø 22mm 29,5x41mm OFF ON 1 0 1 P22921 54x54mm P24447 0 P22850 P24143 P24720 1 0 2 OFF 1 0 2 0 MAN 0 NEUTRAL NEUTRAL IN SILUMIN AUT ON P24894 P24906 P24892 P24907 P24890 P24897 RS ST 0 TR NEUTRAL Series 13,1 72x72mm 0 OFF 1 1 P20688 0 2 2 3 AUT P20673 P20706 1 5 P20772 1 2 P20699 ST TR P20704 2 3 4 P20742 2 3 3 P20701 6 5 4 P20733 0 3 SN TR 6 5 1 4 0 RN ST P20764 2 P22456 RS 0 1 2 3 4 3 0 RS P3814 0 1 2 3 4 2 0 0 MAN P3813 0 1 1 1 0 ON TN 1 2 P20686 P20690 P20830 NEUTRAL Ø 57mm 0 1 0 2 1 P25175 P22714 P10433 NEUTRAL Series 13 - Front plates (DIN-RAIL type) 45x54 mm Handle operated 0 1 0 2 OFF 1 P25103 0 P25138 RS RS 0 ST ST 0 TR P25100 Key operated TR 0 3 SN AUT P25092 P25120 P25105 P24919 1 2 P25102 1 0 2 OFF MAN 0 NEUTRAL AUT ON P25053 P25088 RS RS ST ST 0 TR 0 0 RN 0 TN 1 0 MAN ON P25050 TR 0 3 SN 0 TN P25042 P25070 P25055 P24914 0 RN P25052 1 2 NEUTRAL Series R Mounting examples Series R 32/40 Base mounting type Series R 50/80/125…630 Base mounting type Series R Front mounting type The drawings represents only some mounting types for additional details, please see the relevant instruction sheets Series R Technical informations ALTERNATING CURRENT (IEC / EN 60947-3) Rated operational voltage Ue Rated isolation voltage Ui Rated impulse withstand voltage Uimp Dielectric test voltage for 1 min.corresponding to Ui Rated trequency Conventional free air thermal current Ith Conventional enclosed thermal current Ithe Power loss by 1 pole at Ithe Rated operational current Ie AC-1 Non inductive or slightly inductive loads AC-21A Switching of resistive loads with slight overload Rated power Pe AC-23A Frequent switching of motors or other higly inductive load AC-3 Squirrel - cage motors: starting and stopping of running motors AC-4 Squirrel - cage motor starting, reversing, electric breaking, inching Rated breaking capacity (AC-23A) cos ϕ 0,45 per Ie ≤ 100A cos ϕ 0,35 per Ie > 100A Short circuit characteristic Conditional rated short-circuit current Max. fuse rated current (fuse type gG/gL) Rated short-time withstand current Icw (1s) Rated short-circuit making capacity Icm AC-15 Control of AC electromagnetic loads DIRECT CURRENT (IEC / EN 60947-3) DC-20A Rated operational current Ie Rated operational current Ie DC-1 Non inductive or slightly inductive loads DC-21A Switching of resistive loads with slight overloads Rated power DC-23A Control of high inductive loads series and shunt motors The rounded values correspond to the numbers of poles to connect in series Rated operational current Ie DC-13 Control of electromagnets L/R = 40 ms DC-13 Control of DC electromagnetic loads V V kV kV Hz A A W Series 14 440 440 4 2,5 50/60 16 16 0,34 13 690/600 690/600 6 2,5 50/60 25 25 0,3 A 16 (400V) 25 230 V 400 V 690 V 230 V 400 V 690 V 230 V 400 V 500 V kW kW kW kW kW kW kW kW kW 4 5,5 2,2 3 - 5,5 7,5 11 4 5,5 7,5 2,2 3 3 230 V 400 V 690 V A A A 120 90,4 - 176 176 100 400/415 V kA A kA kA 5 16 0,32 A300 5 25 0,4 1,5 IEC-EN / UL-CSA IEC / UL-CSA IEC 690 V 24 V 48 V 60 V 110 V 220 V 24 V 48 V 60 V 110 V 220 V 380 V 500 V A A 20 10 V max per polo 60 kW kW kW kW kW A A A A A A A 0,3 0,4 0,6 0,8 1,2 10 5 3 1,3 0,5 0,3 0,2 Q300 Series R Technical informations 1 690/600 690/600 6 2,5 50/60 25 25 0,6 R32 690/600 690/600 8 2,5 50/60 32 32 0,8 R40 690/600 690#/600 8# 2,5 50#/60# 45# 45# 1,4 R50 690/600 690#/600 8# 2,5 50/60 50# 50# 1,5 R80 690/600 690#/600 8# 2,5 50/60 80# 75# 2,8 R125 690/600 690/600 8 2,5 50/60 125 120 5,3 R250 690/600 690/600 8 2,5 50/60 250 200 10 R400 690/600 690/600 8 2,5 50/60 400 315 13,6 R630 690/600 690/600 8 2,5 50/60 630 500 25,5 25 32 40# 50# 75# 120 200 250 315 7,5 11 15 5,5 7,5 11 2,2 4 4 11 18,5 22 7,5 15 18,5 5,5 7,5 7,5 11# 22# 22# 7,5# 18,5# 18,5# 5,5 7,5# 11 15# 22# 30# 11# 18,5# 22# 7,5 11 15 18,5# 30# 37# 15# 22# 30# 11 15 18,5 30 45 55 22 30 37 15 22 30 37 55 75 30 37 45 18,5 30 37 204 172 136 296 280 196 296# 336# 196# 400# 336# 260# 484# 544# 316# 780 656 456 936 804 616 5 25 0,5 1,5 5 35 0,8 2 5# 40# 0,8 2 5# 50# 1# 2,5# 5# 63# 1,5# 3# 6 100 2,4 5 8 160 4 7 12 250 5 10 15 315 6,5 15 25 16 32 25 40 25 50 40 75 63 120 100 200 200 60 60 60 60 60 48 42 0,3 0,3 0,5 0,5 1 1 2 2 2,2 2,2 14 16 7 8 4,2 4,8 1,8 2 0,5 0,6 0,4 0,4 0,3 0,3 # Values approved by IMQ 0,3 0,5 1 2 2,2 16 8 4,8 2 0,6 0,4 0,3 0,7 1,4 2 3 6 1 2 2,7 4 8 Series R Technical informations UL / CSA General use 1 phase/2 poles, 3 phase/3 poles Rated current Heavy Pilot Duty (AC) Standard Duty (DC) Rated operational power Across the line AC motor starting DOL-Rating 1 phase 2 poles Series 3 phases 3 poles ENVIROMENTAL DATA Ambient temperature: 1 16 A 20 A 600 P 600 120 V 240 V 480 V 600 V 120 V 240 V 480 V 600 V HP HP HP HP HP HP HP HP 1,5 3 5 5 2 5 10 10 3 6 7,5 6 12 15 -25°C a +60°C -40°C a +80°C Milion of operations Screw driver size recommended torque (Nm) APPROVALS CE-confirmal CSA (Canada) IMQ (Italy) UL-Listed (USA) UR (USA) • Approved as a result of test passed Only CSA approval 13 600 V Code designation Code designation Operation: Storage: MECHANICAL DATA Protection class according to IEC/EN 60529 Actuators Switch bodies Mechanical life Terminal sizes according to IEC/EN 60947-1 gauge form Min./max. wire cross section Fine strands Solid or stranded Max. wire gauges according to UL/CSA (solid/stranded) Terminals 14 mm2 mm2 AWG Type Thread 2/1 0,6 IP40 IP00 1 IP40..IP55 IP00 2 IP40..IP55 IP00 1,5 A2 0,75/2,5 0,75/2,5 14/14 screw M3 3/2 1,2 A3 1/2,5 1/4 10/12 screw M3,5 3/2 1,2 A3 1/2,5 1/4 10/12 screw M4 3/2 1,8 • • • • • • • For CSA 220V e 440V Only UL approval Series R Technical informations R32 R40 R50 R80 R125 R250 R400 R630 32 40 50 63 115 200 250 (315A at 480V) 315 2 5 7,5 10 5 7,5 20 20 2 5 10 15 5 10 25 25 3 7,5 15 20 7,5 15 30 40 7,5 15 30 35 15 30 60 75 10 20 40 50 25 50 75 100 IP66 IP00 1 IP66 IP00 0,5 IP66 IP00 0,5 embedded hexagon embedded hexagon embedded hexagon M10 hexagon 8 mm 10 M12 hexagon 10 mm 14 M14 hexagon 12 mm 19 Operation: Storage: 5 10 20 25 10 20 40 50 -25°C a +60°C -40°C a +80°C IP66 IP20 1 IP66 IP20 1 IP66 IP00 1 IP66 IP00 1 IP66 IP00 1 A5 2,5/6 2,5/10 8/10 screw M4 3/2 1,8 A5 2,5/6 2,5/10 8/10 screw M4 3/2 1,8 A5 2,5/6 2,5/10 8/10 screw M5 3/2 2 A5 2,5/16 2,5/25 4/6 screw 2xM4 3/2 1,2 B7 1,5/35 1,5/50 1/2 screw 2xM6 4/2 • • • • • • • • • • • • • • • • • • • • • • • • • • • Series R Dimensions - Fixing holes Front mounting H A C D F B Series 14 13 1 R32 R40 R50 R80 R125 R250 R400 R630 E L 1 37 35 2 32 50 48 3 62 60 L no. of banks 4 54 75 73 5 87 85 6 100 98 7 112 110 8 125 123 41 58,5 76 93,5 111 128,5 146 163,5 64 51 60 69 87 87 114 105 141 123 168 141 195 159 222 177 249 88 83 113 143 173 203 233 263 293 113 143 173 233 233 323 293 413 353 503 413 593 473 683 533 773 G A B C D E Ø 35 Ø 47 Ø59 72 38 28 Ø 61 67 34 45 Ø 80 90 49 48 23,5 54 or 72 28 or 32 72 32 130 55 118x102 118x191 A 1,5 135 - 120 70 118x180 42 A C 24 Ø 9,5 B C Ø 3,2 BODIES/ACTUATORS Series 13, 1, R32, R40, R50, R80 13 1 R32 R40 R50 R80 H max 4 36x36 o 48x48 A G 14 B Series F (mm x mm) 20 BODIES/ACTUATORS Series 14 fixing C 100 BODIES/ACTUATORS Alternative fixing for series 13, 1, R32, R40 32 9,5 12 3,2 33 5,3 46 5,3 BODIES/ACTUATORS Series R125..R630 Central mounting Ø 22mm 1…6mm +0,2 3,2 0 +0,4 24,1 0 Ø 30 C +0,4 22,3 0 A Series 13 R32 R40 B L B C 2 82 3 94 L N° of banks 4 107 A 1 69 5 119 6 132 7 144 8 157 36 26 Ø 47 86 103,5 121 138,5 156 173,5 191 208,5 41 28 Ø 61 Series R Dimensions - Fixing holes Base mounting S 1…6mm A C A C D F L T B Y E L G X B Series 13 1 R32 R40 R50 R80 R125 R250 R400 R630 1 43 42 2 56 55 L no. of banks 3 68 67 4 81 80 if Y min then X ≥ if Y max then X ≥ 29 75 150 29 75 150 42,5 60 77,5 95 - - - - 59 68 - 77 95 95 122 113 149 75 150 78 150 123 153 183 183 243 - - 71,5 220 77,5 220 IF S then T MIN. 2,5 150 IF S then T MIN. 9,5 90 N H I L L M Q O M ACTUATORS ACTUATORS P R BODIES ACTUATORS Series A B C 54 o 72 72 28 32 51x51 64 28 88 45 D E 72 38 67 34 92 49 F G H I L 58 32 33 9,5 BODIES M N O 36 36 - - 85 85 37 132 P Q R 70 15 (mm x mm) 13 1 R32 R40 R50 R80 R125 R250 R400 R630 78x55 102x102 - - 36 o 48 3,2 17 12 M4 68 130 55 57x148 135 - 120 70 5,3 20 M5 Diagrams 09 3 Poles dahlander switch 14 Ammeter sw. for direct measure without break Y-T8 7 3-4 1-2 Elements Contact 2 4 X X 0 0 1 1 90° Pos. 3 4 1 2 3 Y-T8 Y 8 15-16 13-14 11-12 3 9-10 7-8 2 5-6 3-4 1 1-2 0 1 1 Pos. 90° 3 4 1 2 04 4 Poles on-off switch Element 1 3 5 7 L1 L2 L3 1 16 14 3 X-T7 X X X X X X X X X X X 4 0 4 W-T3 45° 90° Contact Contact Element 7 8 13 V-T2 X 15 16 13 14 4 19-20 17-18 15-16 13-14 11-12 9-10 7-8 5-6 3-4 1-2 2 X X X X X X X X X S R 5 Pos. 0 R T S 3 V 7 7 8 3 4 0 2 Positions 10 6 0 1 1 0 2 3 2 Pos. 4 4 06 2 Poles changeover switch 3 2 X 7 X 1 1 0 2 0 3 2 Pos. 8 6 1 4 Elements Element 1 7-8 5-6 X 3-4 1-2 X Contact 2 5 2 45° 2 45° 25 1 X 23 X X 19 X 15 X X X X X X X X X X X X 2 0 1 0 1 0 2 7 11 7 X 1 0 2 Y 0 5 3 2 Pos. 4 2 45° 4 3 08 3 Poles reversing switch 2 Contact Element 11 X X X 1 0 2 Pos. 11 7 3 1 0 7 12 8 3 2 45° 2 1 Elements 11-12 X 9-10 7-8 X 2 5-6 3-4 1 1-2 X 3 Z-T9 7 Y 45° 90° 6 1 0 8 19-20 17-18 15-16 13-14 11-12 9-10 7-8 5-6 3-4 1-2 2 Y-T8 12 V-T2 X X X X X X X X X X X X X 10 W-T3 5 X-T7 1 L1 L2 L3 2 Positions X X X X X Y 0 Y Positions 0 TR 12 10 TR A 11-12 9-10 7-8 2 5-6 3-4 1 1-2 X X X X X X 3 8 1 X X 1 X X X 0 1 2 2 X 0 3 3 Positions 1 2 90° 23 1 Pole ammeter switch for 4 current transformers L1 L2 L3 L4 4 12 2 6 7 15 A 15 X X 7 12 6 10 X X 4 7 X X 2 X X 0 0 4 2 Positions 9 N L1 L2 L3 SN TN 12 16 X 2 12 8 4 45° 11-12 X 9-10 X 7-8 2 5-6 X X 3-4 X X 1 1-2 11 X 3 4 2 14 X V 8 5 3 15 X X 0 RN RS ST 12 9 15 18 Voltmeter switch 3 phases and 3 phase to phase 11 7 45° 15-16 13-14 11-12 9-10 7-8 5-6 3-4 1-2 15 X X V 19 15 3 19 X X 4 3 4 8 Contact Contact Element 3 4 3 12 8 ST R1S1 Positions 2 0 RS T1R1 S1T1 5 X X 12 10 X 6 3 0 7 10 1 8 17 Voltmeter switch 3 Phase to phase of 2-3 phases lines 9 U-T1 11 X 4 2 8 6 12 10 7 X X X X X 0 3 3 1 Pos. X X X X X 7 45° 7-8 5-6 3-4 1-2 2 12 Star-Delta reversing switch 07 3 Poles changeover switch 11-12 3 9-10 X 7-8 2 5-6 X 3-4 1 1-2 X 23 19 3 X-T7 TR V R1S1 S1T1 T1R1 X X X V-T2 Elements 3-4 1-2 X Contact Element 1 27-28 25-26 23-24 21-22 19-20 17-18 15-16 13-14 11-12 9-10 7-8 5-6 3-4 1-2 Z-T9 9 0 12 9 X 8 X 0 X X RN SN TN 7 15 5 45° W-T3 RS ST TR 05 1 pole changeover switch 25 RS ST TR 2 4 TR ST RS 0 1 0 2 Contact 90° 0 Elements 2 1 Contact 1 Pos. U-T1 4 ST Contact 3 1 3 0 RS L1 L2 L3 0 A 1 L1 L2 L3 Elements Y-T8 6 2 3-4 X X 1-2 X X Positions 15-16 13-14 11-12 3 9-10 7-8 2 5-6 3-4 1 1-2 4 2 X 4 Elements 8 5 16 3 Phase to phase voltmeter switch Elements 0 0 1 7 Contact Element Contact 2 1 11 Pole changing reversing switch X X X X 2 L1 1 6 2 4 6 8 7-8 5-6 3-4 1-2 1 Positions 9 X X X X X X 0 0 22 1 Pole ammeter switch for 3 current transformers 45° 7-8 5-6 3-4 1-2 2 1 4 3 0 Y 90° T SN 8 8 X X X 90° X X X Positions TN X 1 X X X 15 3 Phase voltmeter switch 0 10 0 0 RN 7 X X 20 1 Pole ammeter switch for 1 current transformer X X X 0 12 11 RS ST TR 3 3 11 19 5 4 Pos. 15 7 11-12 9-10 X 7-8 X 2 5-6 3-4 1 1-2 5 L4 L5 L6 2 0 X X 4 3 1 0 2 10 Star-Delta switch 2 4 8 1 8 10 8 2 12 45° 3 16 12 2 5 Z-T9 5 7-8 5-6 3-4 1-2 14 7 U-T1 2 13 X X X 1 3 7 03 3 Poles on-off switch 16 RN 1 3 X X 15 12 Contact 90° 15-16 13-14 11-12 X 3 9-10 X 7-8 2 5-6 3-4 1 1-2 X 4 0 RS TR 11 Elements 4 RN N L1 L2 L3 ST L1 L2 L3 Contact Pos. 02 2 Poles on-off switch 1 16 1 V Elements 3 1 11 16 14 3 X-T7 RN SN TN Contact 0 5 A Elements Elements 0 1 8 V-T2 45° Contact X Z-T9 2 4 L1 L2 L3 4 Element 1 3-4 1-2 0 W-T3 13 5 1 4 Contact 15 19 Voltmeter switch 1 phase and 3 phase to phase 19 Contact U-T1 Contact 3 Contact 01 1 Pole on-off switch Element SERIES R (13, 1) X X X X X X X X X X X X X X 1 2 X 3 Positions 4 1 2 4 3 90° Diagrams 7 8 5 6 4 0 M A Self-input 5 M A Impulse ahead 3 Impulse behind 1 45° 2 7-8 5-6 X X 3-4 X 1-2 Contact Elements 1 A M 0 M A 1 Positions U1 L1 L2 Z1 11 5 Z2 X X X X X Auxiliary winding 11-12 9-10 7-8 2 5-6 3-4 1 1-2 Contact Elements X X X X 4 3 2 11 12 9 10 X X 1 Positions 2 5 U L1 L2 10 4 4 3 Contact Elements X X 9 10 7 X X 1 0 2 1 0 4 3 2 Pos. 1 Elements X X X X 1 15 16 11 12 14 X X X 10 X 7 X X 1 0 3 2 Pos. 12 28 10 9 5 4 3 7 8 6 1 1 2 3 4 4 2 3 4 Pos. 45° 2 16 7 1 16 14 11 12 10 8 6 4 Positions 2 3 2 3 4 2 45° X X 15 X X X X X X X X X X X X X 12 X X X X X X X 10 8 7 5 4 3 Y 0 Y Positions 57 1 Pole step sw. 3 positions + 0 0 876 2 1 19 1 4 Pos. 45° 30° 16 19-20 X 17-18 X 15-16 X 13-14 X 11-12 X 9-10 X 7-8 X 5-6 X 3-4 X 1-2 X 14 12 10 8 4 1 18 12 10 12 1 2 11 3 10 4 9 5 876 6 5 14 10 7 1 4 2 3 4 Pos. 45° 4 3 8 6 2 1 2 45° 11 12 10 X 8 6 1 2 3 4 5 6 4 Positions 2 1 3 45° 7-8 5-6 3-4 1-2 X 7 X 8 X 6 0 1 2 3 4 4 Pos. 2 X 59 1 Pole step sw. 5 positions + 0 16 0 1 14 20 1 2 3 4 24 6 12 2 2 53 1 Pole step sw. 12 positions 2 16 4 1 Pos. 0 2 8 8 X 0 1 2 3 4 Positions 23 X X 58 1 Pole step sw. 4 positions + 0 1 2 3 4 5 6 7 8 9 10 22 18 1 2 8 15 7-8 5-6 3-4 1-2 2 6 20 24 45° 18 10 22 3 20 12 2 Contact Pos. 1 Elements 1 2 3 5 4 18 4 2 3 3 6 19-20 17-18 15-16 13-14 11-12 3 9-10 7-8 2 5-6 3-4 1 1-2 22 20 6 1 2 3 4 11-12 X 9-10 X 7-8 2 5-6 X 3-4 X 1 1-2 X 19 24 1 2 3 4 5 6 14 3 7-8 5-6 X 3-4 X 1-2 X L1 L2 L3 19 15 3 X-T7 15° 30° 26 3 4 5 4 2 45° 23-24 X 21-22 X 19-20 X 17-18 X 15-16 X 13-14 X 11-12 X 9-10 X 7-8 X 5-6 X 3-4 X 1-2 X 6 5 4 8 13 V-T2 4 W-T3 Y 0 Y 52 1 Pole step sw. 10 positions 8 6 15-16 X 13-14 X 11-12 X 9-10 X 7-8 X 5-6 X 3-4 X 1-2 X 1 4 2 X 49 1 Pole step sw. 6 positions 2 45° 38 1 Pole step switch 3 positions Contact 3 2 23 6 2 Elements 2 X 1 3 9 1 4 Z-T9 5 32 23 Y-T8 15 7 30 48 3 Poles step sw. 4 positions A M 0 M A 7 2 3 2 45° 1 0 2 5 V1 U1 V 11-12 9-10 7-8 2 5-6 3-4 1 1-2 1 2 5 4 8 3 34 X 37 Reversing sw. single phase motor + capacitor 3 1 7-8 X 5-6 X 3-4 X 1-2 X Elements U2 45° 3 6 15 1 9 M A 8 6 7 Pos. 36 47 2 Poles step sw. 4 positions 10 12 0 7 X 7 Contact Contact 2 X 32 Single phase reversing sw. + aux. winding M A X X 46 1 Pole step sw. 4 positions X X Elements Elements 1 Elements 0 6 12 10 Pos. 15-16 13-14 11-12 9-10 7-8 5-6 3-4 1-2 Elements M A 4 2 30 Changeover sw. for remote control reverser 11 X 45 4 Poles changeover switch 3 Pos. X X 8 14 5 U-T1 35 4 2 30° 23-24 X 21-22 X 19-20 X 17-18 X 15-16 X 13-14 X 11-12 X 9-10 X 7-8 X 5-6 X 3-4 X 1-2 X 1 2 3 4 5 6 7 8 9 10 11 12 Positons 5 4 2 3 11-12 9-10 7-8 2 5-6 3-4 1 1-2 45° 3 9 X 10 X 8 X X 6 0 1 2 3 4 5 4 Positions 2 X 60 2 Poles step sw. 3 positions + 0 0 1 2 3 11-12 9-10 7-8 2 5-6 3-4 1 1-2 3 Elements Contact Elements X X X X X 16 14 Contact 2 1 7-8 5-6 3-4 1-2 Elements Avv. ausiliario 45° X X 16 13 55 Star-Delta reversing switch 45° 35-36 X 33-34 X 31-32 X 29-30 X 27-28 X 25-26 X 23-24 X 21-22 X 19-20 X 17-18 X 15-16 X 13-14 X 11-12 X 9-10 X 7-8 X 5-6 X 3-4 X 1-2 X 16 14 3 15 0 Y Contact 1 Z2 2 Elements 9 U2 M A 4 Positions Contact 5 7 1 2 3 4 5 6 3 2 45° 15 15-16 13-14 11-12 3 9-10 7-8 2 5-6 3-4 1 1-2 4 1 2 6 5 4 44 4 Poles step switch 2 positions L1 L2 4 1 9 90° 2 8 Contact Z1 8 Pos. 4 1 3 2 U1 3 2 10 Contact 0 3 Positions 1 3 12 51 3 Poles step sw. 6 positions 6 1 2 4 14 11 Contact X 8 15-16 X X 13-14 X X 11-12 X 9-10 X 7-8 X X 5-6 X X 3-4 X X 1-2 X 6 10 7 16 L1 L2 L3 X-T7 18 Elements X 12 4 W-T3 15° 30° 20 Elements X 11 11-12 X 9-10 X 7-8 X 2 5-6 X 3-4 X 1 1-2 X 2 1 3 29 Single phase motor switch + aux. winding 0 2 0 Y 22 8 13 V-T2 24 Elements X X 6 4 Elements X 2 3 2 5 2 1 3 1 2 Contact X 4 6 1 Elements Elements 0 8 43 3 Poles step switch 2 positions X ElementS 2 1 7 Pos. Contact 3 1 Contact 4 X 23-24 X 21-22 X 19-20 X 17-18 X 15-16 X 13-14 X 11-12 X 9-10 X 7-8 X 5-6 X 3-4 X 1-2 X 5 7-8 X 5-6 X 3-4 X 1-2 X Y-T8 15 7 Z-T9 5 45° 23 2 Pos. Contact 5 Contact 6 12 6 5 4 4 Contact 11 23-24 21-22 X 19-20 X X 17-18 15-16 X X 13-14 11-12 X X 9-10 7-8 5-6 X 3-4 1-2 X 3 2 6 Elements 14 U-T1 2 3 1 1 2 42 2 Poles step switch 2 positions 2 13 1 Elements 20 54 Star-Delta switch 50 2 Poles step sw. 6 positions Contact 19 3-4 X 1-2 X Elements 5 2 1 Contact 13 14 12 Contact 11 20 41 1 Pole step switch 2 positions A 19 Contact L1 L2 L3 Contact 25 2 Poles ammeter switch for 3 current transformers 45° 12 X 9 X X X 10 8 X 6 X 0 1 2 3 Pos. 3 4 2 Diagrams 6 X 0 1 2 3 4 4 Pos. 2 23 24 22 45° Contact Elements X 8 7 6 5 20 23-24 21-22 19-20 17-18 15-16 13-14 11-12 9-10 7-8 5-6 3-4 1-2 9 4 3 2 18 X 1 X 15 X 16 14 X X 10 X 7 X 8 X 6 0 1 2 3 4 4 X 2 Pos. 4 Contact Elements 36 11 X 12 10 X 8 X Positions 2 90° X 26 X 23 X 24 X 22 X 20 X 18 X X 16 X 14 X 11 X 6 X 0 1 2 3 4 5 6 4 Positions 2 2 1 5-6 7-8 1-2 3-4 X 5 6 1 2 3 4 X X 1 0 1 0 Pos. 90° 1754 4 Poles on-off switch Contact Elements X 6 7 X 1 0 1 2 Pos. 45° 2 3 3503 3 Poles changeover switch X 8 X X 6 3 0 1 2 3 4 5 6 7 4 2 Positions Y-T8 15 7 60° X X X X X X 8 4 W-T3 L1 L2 L3 2 1 5-6 7-8 1-2 3-4 1 X X X X 1 0 1 0 90° Pos. 5 6 7 8 1 2 3 4 1 3 5 7 9 11 2 4 6 8 10 12 9-10 3 11-12 5-6 2 7-8 1-2 1 3-4 X X X X X X 1 0 1 0 Pos. 90° 9 10 11 12 5 6 7 8 1 2 3 4 3 1 16 14 3 X-T7 16 13 14 7 8 0 5 X X 1 0 2 1 0 Pos. 2 60° 4 7 8 1 2 3 2 2 13-14 15-16 9-10 11-12 5-6 2 7-8 1-2 1 3-4 4 3 8 1 X X X X X 15 16 9 10 11 X X 5 7 8 1 0 2 1 2 X 3 Pos. 2 3 1 5 3 45° 5-6 7-8 1-2 3-4 2 4 X 5 X X 0 1 2 3 1 Pos. 3 4 5271 1 Pole step switch 4 positions + 0 1 1 X 1 0 2 2 0 1 2 Pos. 45° 4 45° 2 3 5-6 7-8 1-2 3-4 2 3252 2 Poles changeover switch 3 1 7 5 Pos. 2 2 1 5-6 7-8 X 1-2 3-4 X 6 X 5 X 1 6 1 2 1 0 1 2 45° Pos. 9 6 10 10 11 X 5 X 1 0 2 Pos. 6 7 1 0 1 2 45° 1 3 8 Pos. 3 3 7 5 11 1 45° 12 2 X 0 1 2 3 4 4 5 2 3 1 7 5 11 9 9-10 11-12 X 5-6 2 7-8 X 1-2 1 3-4 X 5 7 3 3253 3 Poles changeover switch 3 X X X 3 0 1 0 2 8 X 5281 1 Pole step switch 5 positions + 0 7 3 1 7 5 3 0 1 16 0 2 1-2 3-4 X 10 13 5261 1 Pole step switch 3 position + 0 5 3 10 11 60° 1 3251 1 Pole changeover switch 15 10 3 1 5 7 11 9 13 15 2 4 6 8 10 X 8 9 X 3504 4 Poles changeover switch 12 X 13 V-T2 9-10 3 11-12 X 5-6 X 2 7-8 1-2 1 3-4 X 1 3 5 7 16 X Y 0 5 X 2 2 4 6 X X X X 10 11 X 3 1 5 7 11 9 1756 6 Poles on-off switch 45° X X 9 X X 1 3 5 8 X Z-T9 5 15-16 13-14 11-12 3 9-10 7-8 2 5-6 3-4 1 1-2 X 10 X 0 4 2 4 12 X U-T1 Y 1 3 1753 3 Poles on-off switch 28 70 Star-Delta switch X 4 0 30 X 6 0 1 2 3 4 5 6 1 0 1 Pos. 14 32 X X X 14 34 X 15-16 13-14 11-12 9-10 7-8 5-6 3-4 1-2 Elements 45° Elements 11-12 9-10 7-8 2 5-6 3-4 1 1-2 1 3 35-36 33-34 31-32 29-30 27-28 25-26 23-24 21-22 19-20 17-18 15-16 13-14 11-12 9-10 7-8 5-6 3-4 1-2 7 0 1 6 2 5 3 4 2 0 1 2 3 35 45° 67 1 Pole step sw. 7 positions + 0 3 4 2 3 12 X X 64 1 Pole step sw. 6 positions + 0 6 5 4 10 15 X 1 0 2 Contact X 8 2 4 X X Elements 7 1 3 6 5 1 3 Contact 10 X X 90° Elements X Pos. 0 1 12 X 1-2 3-4 Contact X X 1 Elements 14 2 4 2 2 Contact Contact Elements 0 1 4 Positions 16 63 3 Poles step sw. 4 positions + 0 3 0 1 2 3 4 5 6 13-14 15-16 9-10 3 11-12 5-6 2 7-8 1-2 1 3-4 4 6 Elements 15-16 13-14 11-12 3 9-10 7-8 2 5-6 3-4 1 1-2 15 2 8 X Contact 45° 1 1752 2 Poles on-off switch Elements 3 4 4 X X 66 3 Poles step sw. 6 positions + 0 2 5 10 1 4 6 X 6 13 1 0 12 Contact 0 X 0 1 Elements 62 2 Poles step sw. 4 positions + 0 11 Contact Pos. 1 14 X X 1-2 3-4 Elements 2 X 1 Contact 4 0 1 2 3 16 Elements 2 18 X Contact 3 6 X X Elements 8 X X 5 2 2 2 9-10 3 11-12 5-6 2 7-8 1-2 1 3-4 Contact 4 X X 1 22 20 Contact 10 21 Elements 12 9 X X Contact 11 23-24 21-22 19-20 17-18 15-16 13-14 11-12 9-10 7-8 5-6 3-4 1-2 Elements 14 Contact Contact Elements 1 X X 6 13 Contact 2 X 3 1 7 5 11 9 15 13 1751 1 Pole on-off switch 45° 24 16 X Elements 3 X 2 3 4 Contact 4 19-20 17-18 15-16 13-14 11-12 9-10 7-8 5-6 3-4 1-2 6 5 Contact 5 45° 3254 4 Poles changeover switch SERIES R (R32..R630) 0 1 Elements 3 65 2 Poles step sw. 6 positions + 0 20 2 Contact 1 Elements 0 Elements 61 3 Poles step sw. 3 positions + 0 X 11 X X 5 X X 7 0 1 2 3 4 5 1 Positions 3 12 Diagrams 0 0 1 1 1 Pos. 2 45° 02 2 Poles on-off switch 1 3 6 5 8 1 1 0 2 2 1 Pos. 7303 3 Poles reversing switch 1-2 3-4 U1 0 0 1 1 Pos. 45° 1 2 3 4 Contact Elements TR 12 6 2 W1 11 X 5 X X 2 4 6 12 2 6 1 2 1 0 2 3 Pos. 5-6 7-8 1-2 3-4 X 5 6 X X 0 0 1 1 Pos. 45° 1 2 3 4 04 4 Poles on-off switch 1 13 RS 6 1 2 45° 1 2 3 4 4 2 8 7503 Star-Delta switch W2 U1 6 14 0 1 8 W1 1 5 16 V2 8 U2 1 1 1-2 3-4 X 1 0 2 1 0 1 2 Pos. 2 1 60° Contact Elements 0 13 14 15 16 2 1 5 6 1 2 8 Y 5-6 7-8 X 1-2 3-4 X Contact X X X X X X X X X X X Elements 13-14 15-16 9-10 3 11-12 5-6 2 7-8 1-2 1 3-4 4 X 5 1 0 2 1 0 1 2 Pos. 4 V2 0 Contact Elements X X X X X X X X X 5 16 8 U2 V1 13 14 15 16 5 X X Y 0 Pos. 13 15 2 6 8 1 2 Contact W1 1 9-10 3 11-12 X 5-6 2 7-8 X 1-2 1 3-4 X L1 L2 L3 X 4 Positions 3 N L1 L2 L3 0 RS 12 6 4 10 45° 9-10 3 11-12 X 5-6 X 2 7-8 1-2 1 3-4 10 9 X X 12 X 6 X X X 0 3 Positions 4 L1 L2 L3 5 9 10 10 12 4 8 A 15 13 5 10 X 5 6 1 2 X 1 0 2 Pos. 9 X 8 1 0 5 13-14 15-16 9-10 3 11-12 5-6 2 7-8 1-2 1 3-4 4 2 45° 4 X X X X X 8 X X X X X 4 X 0 1 X 2 Positions 3 2 1 5 4 2 8 6 12 10 Elements U1 3 12 V TR 4 10 X 22 1 Pole ammeter switch for 3 current transformers 07 3 Poles changeover switch 1 6 14 13-14 15-16 9-10 3 11-12 5-6 2 7-8 1-2 1 3-4 2 45° Pos. W2 4 6 8 7553 Star-Delta switch Y 5 X 14 X ST 4 2 8 6 13 15 2 V1 9 RN 06 2 Poles changeover switch L1 L2 L3 13 4 45° 5 6 1 2 X 8 X 1 0 2 4 45° 1 5-6 7-8 1-2 3-4 7 0 1 6 2 5 3 4 19 Voltmeter switch 1 phase and 3 phase to phase X 12 X 45° X 6 X X 2 0 1 2 3 4 3 Pos. 2 4 6 8 10 12 14 X 0 X X 67 1 Pole step switch 7 positions + 0 N L1 L2 L3 X X 10 16 Pos. 45° X 13-14 15-16 X 9-10 3 11-12 X 5-6 X X 2 7-8 1-2 X 1 3-4 Contact 5 Pos. Y 0 1 Pos. 7 05 1 Pole changeover switch 0 Y 4 4 14 10 12 4 Elements 16 6 Contact 14 15 0 5 Contact 13 X X X X Elements 1 5-6 7-8 1-2 3-4 Contact Contact Elements 2 13 15 2 V1 X X X X X X X X X X X 4 8 U2 Elements 45° 90° 13-14 15-16 9-10 3 11-12 5-6 2 7-8 1-2 1 3-4 16 5 V2 Elements Y Contact W1 1 0 1 2 4 6 8 Elements 6 14 1 SN TN 2 8 0 RN 9 X 3 6 Positions V TR L1 L2 L3 5 5 14 X X 1 0 2 3 0 13 2 18 Voltmeter switch 3 phase and 3 phase to phase ST U1 0 9 2 4 6 0 X X X X X X 5 13 57 1 Pole step switch 3 positions + 0 L1 L2 L3 1 V 13-14 15-16 9-10 3 11-12 5-6 2 7-8 1-2 1 3-4 4 6 4 8 1 3 5 7 7323 Star-Delta switch W2 5 45° 5-6 7-8 1-2 3-4 Contact V1 4 45° ST Elements 45° 9-10 3 11-12 X 5-6 X 2 7-8 1-2 1 3-4 X 3 Pos. 0 RS 2 Contact 5 1 2 1 3 5 03 3 Poles on-off switch L1 L2 L3 2 Elements 11 0 0 1 16 3 Phase to phase voltmeter switch 0 1 6 5 X X 1 0 2 2 4 X X X 3 10 RN SN TN X X X 9-10 X 11-12 5-6 X 2 7-8 1-2 1 3-4 X 9 Contact X RS ST TR 16 Elements Contact Elements 15 3-4 1-2 1 9 5 1 W1 RS ST TR X X 14 Elements 13-14 15-16 9-10 X 3 11-12 X 5-6 2 7-8 1-2 1 3-4 X 4 13 Contact 1 45° 4 V1 2 Contact 13 15 2 1V Elements 6 2V L1 L2 L3 Elements 8 4 2 8 6 12 10 16 14 10 TR ST RS 1W 1 RN 16 5 2 Elements 0 01 1 Pole on-off switch L1 L2 L3 2W 1 Contact 1 14 Contact 2U U1 Elements 6 45 4 Poles changeover switch 08 3 Poles reversing switch SERIES 14 1U 0 3 1 2 90° 13-14 15-16 9-10 11-12 5-6 7-8 1-2 3-4 Contact 7293 3 Poles Dahlander switch 1 45° 14 X 10 X 12 X X 6 X X 8 X 0 1 2 3 4 5 6 7 Positions 1 2 4 Series R Circuit diagrams 30° 60° Date Order N. Company Contact 45° 90° 6 5 4 3 2 Banks 1 8 7 6 5 4 3 2 Banks 1 X Contact closed Contacts Contacts Notes Positions Contact closed in several positions Rated current Ie AC-21A (A) Actuator Delivery date Positions 29 - 30 31 - 32 25 - 26 27 - 28 21 - 22 23 - 24 17 - 18 19 - 20 13 - 14 15 - 16 9 - 10 11 - 12 5-6 7-8 1-2 3-4 XX Quantity from 20A to 25A 7 Fax from 32A to 315A 8 31 - 32 29 - 30 27 - 28 25 - 26 23 - 24 21 - 22 19 - 20 17 - 18 15 - 16 13 - 14 11 - 12 9 - 10 7-8 5-6 3-4 1-2 Ph. 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 1 2 29 30 31 32 25 26 27 28 21 22 23 24 17 18 19 20 13 14 15 16 9 10 11 12 5 6 7 8 1 2 3 4 Spring return Front mounting Base mounting Series R Ordering example for special switches 0 M Company Rossi & Bianchi A Contact Ph. 45° X 90° 4 3 2 Banks 1 8 7 6 5 4 3 2 Banks 1 X Contact closed X X X X X 0 M A Contacts Contacts XX Positions Contact closed in several positions Rated current Ie AC-21A (A) Actuator Notes 02 555555 1 week Delivery date 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 1 2 29 30 31 32 25 26 27 28 21 22 23 24 17 18 19 20 13 14 15 16 Positions 29 - 30 31 - 32 25 - 26 27 - 28 21 - 22 23 - 24 17 - 18 19 - 20 13 - 14 15 - 16 9 - 10 11 - 12 5-6 7-8 1-2 3-4 10 pieces Fax pl 5 02 555555 32 from 20A to 25A 6 Rossi 31 from 32A to 315A 7 31 - 32 29 - 30 27 - 28 25 - 26 23 - 24 21 - 22 19 - 20 17 - 18 15 - 16 13 - 14 11 - 12 9 - 10 7-8 5-6 3-4 1-2 Quantity Ex am 8 Order N. 0000/00 Date e 30° 60° 9 10 11 12 5 6 7 8 1 2 3 4 Spring return 20 54 x 54mm (Standard) - complete of legend plate X Front mounting Base mounting Special version Changeover Sw. 4x1600A Disconnector Sw. 2200A visit our web site: www.breter.it www.breter.it Breter s.r.l. Via Cardinale Riboldi, 161 I - 20037 Paderno Dugnano - Milano Italy Tel. +39 0299061.1 Fax +39 029103516 Cam switches R series - 9/2003
Similar documents
Section K - Sprecher + Schuh
All control knobs and shafts are spray proof and dust proof to IP65.
More informationImperial Registers and Grilles
BASEBOARD RETURN AIR ............................................................................................................................ 8-8 – 8-9 PROJECTION — 2" PROJECTION — WHITE ........
More informationBoletín Oficial del Principado de Asturias
11030414M 71770476B 71760883D 10952222J 11066554N 10949633T 11075339B 11026977H 71762333X 71645717G 71772366S 11021180V 11057894T 10949642D 11053228A 10948242N 11062416Z 76958174J 10729547R 7188443...
More information