Cam switches R series

Transcription

Cam switches R series
www.breter.it
Cam switches R series
from 16A to 315A
PROFILE
BRETER has been established in the fifties as a manufacturer of switches for industrial applications and achieved a key specialist role in the market of electromechanical low-voltage industrial controls, especially due to its expertise on custom-designed products.
Product quality has been Breter distinctive and prestigious way to be succesful through the years.
Thanks to its development and constructive policies, today Breter's strength is a unit of 20.000 square meters, a specialists equipe, the leading position into the
major international markets besides Italy and a wordwide distribution network.
The Company works in Quality Warranty to ensure top quality levels, also confirmed by products conformity to UL/CSA and IEC/EN national and international
regulations and a number of approvals.
Breter faces the future with technological innovations applied to design systems, workshop, production and Quality Warranty structures.
High innovative production organizations are based on automatic assembly lines and automatic injection plastic materials presses as well as advanced gears for
quality control carried out on 100% of finished products.
Engineering systems exploit CAD technology to develop new solutions and improve products quality and functionality.
The Company Test Laboratory is equipped with gears and instruments suitable for electrical, mechanical and climatic high reliable tests both on prototypes and
finished products.
Breter complete range of standard and special versions for all power and control functions in electrical and electronic applications is typically used by OEM,
panel builders and installers in the following fields: tools and industrial machines, automation, transports, off-shore, lifting equipment, energy production and distribution.
The whole Breter range covers more than 4 thousands products out of the catalog in addition to an even higher number of custom-designed products; cam switches and switch disconnectors from 10A up to 630A and a complete line of push buttons, selector switches and pilot lights Ø 16 - 22 - 30 mm with plenty of choices as far as functions and outward solutions.
Cam switches
R SERIES
Cam switches
For rated current from 16A to 315A
Wide range of electrical functions
Special schemes
available on request
Type of fixing: front mounting, base
mounting or central fixing Ø 22mm
Actuator with screw fixture or
central fixture Ø 22mm
LEGENDA
Black legend plate
Grey legend plate
Silver-grey legend plate
Grey/black actuator
Yellow/red actuator
Key removable
1
General features
The features and the use of the best
standard of materials assure the quality,
reliability and safety of breter cam-switches, as confirmed by the approvals
granted by the most important international test houses.
• Use for breaking, changing-over, making and starting of circuits with inductive
or resistive electric loads; rated loads from 16A up to 315A
• High resistance to mechanical stress and to tracking, dimensional stability.
• Double break silver alloy contacts
• Screw terminals for cables with/without cable terminal, of easy identification
• Special electrical schemes available on request
• Wide range of attachments to obtain many versions
• Quality and reliability for the highest safety of operation on control circuits
• Convenience and pratical use
• Compliance with international specifications
• Ip degree of protection according to IEC 529, CEI 70-1
• CEI/EN 60445 is the standard applies to the identification and marking of
terminals of electrical equipment
Typical applications of cam switches
On-off switch
Two-position switches used to connect and disconnet any electtical supply. They are used in a variety of power
switchig applications like manual control of direct on-line motors and isolation of motor branch circuits.
Changeover switch
Three-position switches used in power applications to change between alternate electrical supplies. Changeover
switches are typically used to switch the power supply from the primary source to a stand-by generator or emergency
supply in the event of a power outage.
Step switch
Multi-position switches used to connect a variety of loads to an electrical supply in a predeterminated logical sequence.
A typical application would be temperature control of a heating oven or furnace.
Reversing switch
Three-position (Forward, Off,Reverse) switches used to manually control the direction of rotation of a motor. Operating
the switch changes the wiring configutation to the motor to operate in the forward or reverse direction.
Dahlander switch
Three-position (1st speed, off, 2nd speed) switches used to select 2 different speeds of rotation of a motor. Operating
the switch changes the wiring configutation and the number of poles of the motor (i.e. 4/2, 8/4, etc.).
The second speed is always two times the first one.
Star Delta switch (Wye-Delta)
Three-position (Off, Wye, Delta) switches used to manually control the reduced voltage starting of a motor. Operating
the switch changes the wiring configutation to the motor from a star configuration to a delta cofiguration once the
person operating the conrtoller determines the motor is up to speed.
Ammeter switch
Multi-position switches used to connect one or more phases of the electrical supply to an ammeter, so that the current
in each phase can be displayed on the ammeter.
Voltmeter switch
Multi-position switches used to connect two lines of the electrical supply system to a voltmeter, so that the voltage
between lines (phase-to-phase or phase-to-neutral) can be displayed on the voltmeter.
Utilization categories
To choose the most suitable and economic cam-switch in relation to the
specific application it is necessary to
compare the operating parameters of
the unit to be controlled (voltage,
current and power) with the camswitch performance.
To make this comparison consult the
IEC/EN 60947-1-3, 60947-5-1,
60204-1, specifications for the utilization categories.
• AC-1
• AC-3
• AC-4
• AC-12
• AC-13
• AC-15
• AC-20
• AC-21
• AC-22
• AC-23
Non-inductive or slightly inductive loads, resistance furnaces
Squirrel-cage motors: starting switching off motors during running
Squirrel-cage motors: starting, plugging, inching
Control of resistive loads and solid state loads with isolation by optocouplers
Control of solid state loads with transformer isolation
Control of a.c. electromagnetic loads
Connecting and disconnecting under no-load condition
Switching of resistive loads, including moderate overloads
Switching of mixed resistive and inductive loads, including moderate overloads
Switching of motor loads or other highly inductive loads
• DC-1 Non-inductive or slightly inductive loads, resistance furnaces
• DC-3 Shunt-motors, starting, plugging, inching, dynamic breaking of motors
• DC-5 Series-motors, starting, plugging, inching, dynamic breaking of motors
• DC-12 Control of resistive loads and solid state loads with isolation by optocouplers
• DC-13 Control of d.c. electromagnets
• DC-20 Connecting and disconnecting under no-load conditions
• DC-21 Switching of resistive loads, including moderate overloads
• DC-22 Switching of mixed resistive and inductive loads, including moderate
overloads (e.g. shunt motors)
• DC-23 Switching of highly inductive loads (e.g. series motors)
Average full load currents of squirrel cage motors
(alternate current 4 poles 1500 rpm)
kW
0,06
0,09
0,12
0,18
0,25
0,37
0,55
0,75
1,10
1,50
2,20
3,00
4,00
5,50
7,50
11,00
15,00
18,50
22,00
30,00
37,00
45,00
55,00
75,00
90,00
110,00
Ampére
230V
0,41
0,62
0,83
1,16
1,43
1,90
2,67
3,45
4,75
6,05
8,45
11,70
15,00
19,50
25,50
37,00
50,00
60,50
72,50
97,50
117,00
141,00
173,00
229,00
272,00
333,00
400V
0,24
0,36
0,48
0,67
0,83
1,10
1,55
2,00
2,75
3,50
4,90
6,80
8,70
11,30
14,80
21,50
29,00
35,00
42,00
56,50
68,00
82,00
100,50
133,00
158,00
193,00
500V
0,19
0,29
0,38
0,54
0,66
0,88
1,24
1,60
2,20
2,80
3,90
5,40
7,00
9,10
11,90
17,00
23,00
28,00
33,50
45,00
54,50
64,00
80,00
106,00
126,00
153,00
690V
0,14
0,21
0,28
0,39
0,48
0,64
0,90
1,16
1,60
2,05
2,85
3,90
5,00
6,50
8,60
12,50
17,00
20,50
24,50
32,50
39,50
47,00
57,00
77,00
91,00
110,00
Series R
Front mounting - On-off switches
Standard handle
Rated current
Ie AC-21A (A)
IP
protection
Dimensions
mm x mm
0
16
40
3 poles
2 banks
4 poles
2 banks
48
14.01.11
14.02.11
14.03.11
14.04.11
90°
54
13.01.11
13.01.11C
1.01.11
13.02.11
13.02.11C
1.02.11
13.03.11
13.03.11C
1.03.11
13.04.11
13.04.11C
1.04.11
RE321751A
RE401751A
RE501751A
RE801751A
RE1251751A
RE321752A
RE401752A
RE501752A
RE801752A
RE1251752A
RE2501752A
RE321753A
RE401753A
RE501753A
RE801753A
RE1251753A
RE2501753A
RE4001753A
RE6301753A
RE321754A
RE401754A
RE501754A
RE801754A
RE1251754A
RE2501754A
RE4001754A
RE6301754A
1
72
25
32
40
50
75
120
200
250
315
2 poles
1 banks
64
88
90°
1
66
6 poles
3 banks
45°
1
0
20
1 pole
1 bank
0
130
RE321756A
RE401756A
RE501756A
RE801756A
RE1251756A
RE2501756A
Padlockable handle
Rated current
Ie AC-21A (A)
20
25
IP
protection
Rated current
Ie AC-21A (A)
32
40
50
75
120
200
250
315
IP
protection
Dimensions
mm x mm
90°
0
54
72
1
Dimensions
mm x mm
67
1
66
90°
90
0
135
3 poles
2 banks
13.03.11-OZ
1.03.11-OZ
3 poles
2 banks
RE321753G
RE401753G
RE501753G
RE801753G
RE1251753G
RE2501753G
RE4001753G
RE6301753G
4 poles
2 banks
13.04.11-OZ
1.04.11-OZ
4 poles
2 banks
RE321754G
RE401754G
RE501754G
RE801754G
RE1251754G
RE2501754G
RE4001754G
RE6301754G
6 poles
3 banks
RE321756G
RE401756G
RE501756G
RE801756G
RE1251756G
RE2501756G
3 poles
2 banks
13.03.11-OM
1.03.11-OM
3 poles
2 banks
RE321753N
RE401753N
RE501753N
RE801753N
RE1251753N
RE2501753N
RE4001753N
RE6301753N
4 poles
2 banks
13.04.11-OM
1.04.11-OM
4 poles
2 banks
RE321754N
RE401754N
RE501754N
RE801754N
RE1251754N
RE2501754N
RE4001754N
RE6301754N
6 poles
3 banks
RE321756N
RE401756N
RE501756N
RE801756N
RE1251756N
RE2501756N
Series R
Base mounting - on-off switches
Standard handle
Rated current
Ie AC-21A (A)
20
IP
protection
Dimensions
mm x mm
90°
0
54
1
72
25
32
40
50
75
120
200
250
315
54
64
90°
1
66
88
0
130
3 poles
2 banks
13.03.11-3
13.03C-3
1.03.11-3
4 poles
2 banks
13.04.11-3
13.04C-3
1.04.11-3
6 poles
3 banks
RA321753A
RA401753A
RA501753A
RA801753A
RA1251753A
RA2501753A
RA4001753A
RA6301753A
RA321754A
RA401754A
RA501754A
RA801754A
RA1251754A
RA2501754A
RA4001754A
RA6301754A
RA321756A
RA401756A
RA501756A
RA801756A
RA1251756A
RA2501756A
Padlockable handle
Rated current
Ie AC-21A (A)
20
25
IP
protection
Rated current
Ie AC-21A (A)
32
40
50
75
120
200
250
315
IP
protection
Dimensions
mm x mm
90°
0
55
72
1
Dimensions
mm x mm
67
1
90°
90
0
66
135
3 poles
2 banks
13.03.11-SP
1.03.11-SP
3 poles
2 banks
RA321753G
RA401753G
RA501753G
RA801753G
RA1251753G
RA2501753G
RA4001753G
RA6301753G
4 poles
2 banks
13.04.11-SP
1.04.11-SP
4 poles
2 banks
RA321754G
RA401754G
RA501754G
RA801754G
RA1251754G
RA2501754G
RA4001754G
RA6301754G
6 poles
3 banks
RA321756G
RA401756G
RA501756G
RA801756G
RA1251756G
RA2501756G
3 poles
2 banks
13.03.11-OP
1.03.11-OP
3 poles
2 banks
RA321753N
RA401753N
RA501753N
RA801753N
RA1251753N
RA2501753N
RA4001753N
RA6301753N
4 poles
2 banks
13.04.11-OP
1.04.11-OP
4 poles
2 banks
RA321754N
RA401754N
RA501754N
RA801754N
RA1251754N
RA2501754N
RA4001754N
RA6301754N
6 poles
3 banks
RA321756N
RA401756N
RA501756N
RA801756N
RA1251756N
RA2501756N
Series R
On-off switches
Central mounting Ø 22mm
Rated current
Ie AC-21A (A)
IP
protection
Positions
90°
0
20
32
Control
1
66
90°
1
0
40
3 poles
2 banks
13.03.11-2M
13.03.11-2C
4 poles
2 banks
13.04.11-2M
13.04.11-2C
6 poles
3 banks
handle
key
2 poles
1 bank
13.02.11-2M
13.02.11-2C
handle
key
handle
key
RC321752B
RC321752DD
RC401752B
RC401752DD
RC321753B
RC321753DD
RC401753B
RC401753DD
RC321754B
RC321754DD
RC401754B
RC401754DD
RC321756B
RC321756DD
RC401756B
RC401756DD
Thermoplastic enclosed switch, front actuator (130x95 h91mm)
Rated current
Ie AC-21A (A)
16
20
25
32
IP
protection
Dimensions
mm x mm
90°
0
54
1
3 poles
4 poles
3 poles
4 poles
14.03.11-5S
13.03.11-5S
1.03.11-5S
2.03.11-5S
14.04.11-5S
13.04.11-5S
1.04.11-5S
2.04.11-5S
14.03.11-5R
13.03.11-5M
1.03.11-5M
2.03.11-5M
14.04.11-5R
13.04.11-5M
1.04.11-5M
2.04.11-5M
Enclosed switch side lever
Rated current
Ie AC-21A (A)
20
25
32
50
75
120
IP
protection
54
Fiber-glass filled
enclosure
3 poles
13.03.11-5L
1.03.11-5L
2.03.11-5L
3.03.11-5L
4.03.11-5L
4 poles
13.04.11-5L
1.04.11-5L
2.04.11-5L
3.04.11-5L
4.04.11-5L
IP
protection
55
Metal enclosure
3 poles
13.03.11-4L
1.03.11-4L
2.03.11-4L
3.03.11-4L
4.03.11-4L
5.03.11-4L
4 poles
13.04.11-4L
1.04.11-4L
2.04.11-4L
3.04.11-4L
4.04.11-4L
5.04.11-4L
Yellow cover and red handle
Series R
Changeover switches
Front mounting - Standard handle
Rated current
Ie AC-21A (A)
16
20
25
32
40
50
75
120
200
250
315
IP
protection
Dimensions
mm x mm
45°
0
1
2
40
48
54
72
45°
0
1
2
64
88
66
2 poles
2 banks
14.06.11
13.06.11
13.06.11C
1.06.11
RE323252A
RE403252A
RE503252A
RE803252A
RE1253252A
60°
0
1
1 pole
1 bank
14.05.11
13.05.11
13.05.11C
1.05.11
RE323251A
RE403251A
RE503251A
88RE803251A
2
130
3 poles
3 banks
14.07.11
13.07.11
13.07.11C
1.07.11
RE323253A
RE403253A
RE503253A
RE803253A
RE1253253A
RE2503503A
RE4003503A
RE6303503A
4 poles
4 banks
14.45.11
13.45.11
13.45.11C
1.45.11
RE323254A
RE403254A
RE503254A
RE803254A
RE1253254A
RE2503504A
RE4003504A
RE6303504A
Front mounting - Padlockable handle
Rated current
Ie AC-21A (A)
20
25
32
40
50
75
120
IP
protection
Dimensions
mm x mm
54
72
1
0
45°
67
2
66
90
135
3 poles
3 banks
13.07.11-OZ
1.07.11-OZ
RE323253G
RE403253G
RE503253G
RE803253G
RE1253253G
4 poles
4 banks
13.45.11-OZ
1.45.11-OZ
RE323254G
RE403254G
RE503254G
RE803254G
RE1253254G
Base mounting - Padlockable handle - Doorlock
Rated current
Ie AC-21A (A)
20
25
32
40
50
75
120
IP
protection
Dimensions
mm x mm
54
72
1
66
0
45°
2
67
90
135
3 poles
3 banks
13.07.11-SP
1.07.11-SP
RA323253G
RA403253G
RA503253G
RA803253G
RA1253253G
4 poles
4 banks
13.45.11-SP
1.45.11-SP
RA323254G
RA403254G
RA503254G
RA803254G
RA1253254G
Series R
Changeover switches
Central mounting Ø 22mm
Rated current
Ie AC-21A (A)
IP
protection
Positions
1
0
Control
45°
2
20
66
32
1
0
45°
2
40
handle
key
3 poles
3 banks
13.07.11 - 2M
13.07.11 - 2C
4 poles
4 banks
13.45.11 - 2M
13.45.11 - 2C
handle
key
handle
key
RC323253B
RC323253DC
RC403253B
RC403253DC
RC323254B
RC323254DC
RC403254B
RC403254DC
Enclosed switch side lever
Rated current
Ie AC-21A (A)
20
25
32
50
75
120
IP
protection
55
Fiber-glass filled
enclosure
3 poles
13.07.11-5L
1.07.11-5L
2.07.11-5L
3.07.11-5L
4.07.11-5L
4 poles
13.45.11-5L
1.45.11-5L
2.45.11-5L
3.45.11-5L
4.45.11-5L
IP
protection
54
Metal enclosure
3 poles
13.07.11-4L
1.07.11-4L
2.07.11-4L
3.07.11-4L
4.07.11-4L
5.07.11-4L
4 poles
13.45.11-4L
1.45.11-4L
2.45.11-4L
3.45.11-4L
4.45.11-4L
5.45.11-4L
Series R
Motor switches - Base mounting
Standard handle
REVERSING SWITCHES
Rated
Rated
IP
Dim.
current
power Pe protect. mmxmm
Ie AC-21A (A) AC-23A (kW)
16
5,5
20
7,5
25
32
40
50
75
120
11
18,5
22
22
30
45
40
40
3 poles
1
2
3 banks
14.08.11
13.08.11
13.08.11C
1.08.11
RE327303A
RE407303A
RE507303A
RE807303A
RE1257303A
48
54
72
64
66
45°
0
88
130
DAHLANDER SWITCHES
For single phase 45° For single phase
motor with
motor with 1 0
auxiliary M 0 M
A
winding A
capacitor
3 banks
3 banks
13.32.11
13.32.11C
1.32.11
7,5
0
25
32
40
50
75
11
18,5
22
22
30
4 banks
120
45
72
88
Y
2
4 banks
7 banks
13.09.11
13.09.11C
1.09.11
RE327293A
RE407293A
RE507293A
RE807293A
RE1257293A
0 Y
2
2
13.11.11
13.11.11C
1.11.11
Y
5 banks
30°-60°
13.70.11
13.70.11C
1.70.11
RE327553A
RE407553A
RE507553A
RE807553A
reversing switch
0
Y
4 banks
60°
13.10.11
13.10.11C
1.10.11
RE327323A
RE407323A
RE507323A
RE807323A
64
66
1
3 poles pole chan-45°
ging and
reversing 1 0 1
0
switch 0
SWITCHES
0
4 banks
54
40
45°
0
YY
45°-90°
20
2
13.37.11
13.37.11C
1.37.11
Y
Rated
Rated
IP
Dim.
current
power Pe protect. mmxmm
Ie AC-21A (A) AC-23A (kW)
45°
3 poles
Dahlander
45°-90°
13.54.11
13.54.11C
1.54.11
13.12.11
13.12.11C
1.12.11
Y
130
RE1257503A
0
60°
Rated
Rated
IP
Dim.
current
power Pe protect. mmxmm
Ie AC-21A (A) AC-23A (kW)
54
20
7,5
40
25
11
72
For single phase motor
with auxiliary winding
2 banks
13.29.11
13.29.11C
1.29.11
0
For remote
control reverser
M
A
M
A
2 banks
13.30.11
13.30.11C
45°
0
45°
Enclosed switch side lever
Rated
Rated
IP
current
power Pe protect.
Ie AC-21A (A) AC-23A (kW)
20
7,5
25
11
55
32
18,5
50
22
75
30
120
40
54
3 poles
reversing switches
1
45°
13.08.11 - 5L
1.08.11 - 5L
2.08.11 - 5L
3.08.11-5L
4.08.11-5L
5.08.11-4L
0
2
3 poles
Dahlander
switches
45°
13.09.11 - 5L
1.09.11 - 5L
2.09.11 - 5L
3.09.11-5L
4.09.11-5L
5.09.11-4L
1
0
2
Y switches
0
45°-90°
13.10.11 - 5L
1.10.11 - 5L
2.10.11 - 5L
3.10.11 - 5L
4.10.11 - 5L
5.10.11 - 4L
Y
M
A
Series R
On-off switches - Front mounting
Rated current
Ie AC-21A (A)
IP
Protection
Positions
16
20
25
32
40
0
1
66
2
48
54
1
2
3
40
Dimensions
mm x mm
45°
72
3
0
64
45°
0 1
20
25
32
40
40
4
1
66
2
2
3
54
45°
72
3
0
4
64
45°
0 1
20
25
32
40
40
5
4
1
66
2
2
3
54
45°
72
3
0
4
5
64
45°
0 1
20
40
16
20
40
45°
54
72
7 0 1
6
2
5
3
4
45°
48
54
72
6
5
4
1
20
40
45°
54
72
45°
54
72
30°
54
72
2
4
2
3
6 5 4
12
20
54
72
3
40
40
45°
3
1
20
45°
54
72
2
40
1
20
2
40
1
20
2
3
10
9
876
3
4
5
12 1 2
11
3
10
4
9
5
876
30°
1 pole
2 poles
3 poles
2 banks
14.57.11
13.57.11
13.57.11C
1.57.11
RE325261A
RE405261A
2 banks
13.58.11
13.58.11C
1.58.11
RE325271A
RE405271A
3 banks
13.59.11
13.59.11C
1.59.11
RE325281A
RE405281A
3 banks
13.64.11
13.64.11C
4 banks
14.67.11
13.67.11
13.67.11C
3 banks
5 banks
13.60.11
13.60.11C
1.60.11
13.61.11
13.61.11C
1.61.11
4 banks
13.62.11
13.62.11C
1.62.11
6 banks
13.63.11
13.63.11C
1.63.11
6 banks
13.65.11
13.65.11C
9 banks
13.66.11
13.66.11C
2 banks
13.42.11
13.42.11C
3 banks
13.43.11
13.43.11C
4 banks
13.47.11
13.47.11C
6 banks
13.50.11
13.50.11C
6 banks
13.48.11
13.48.11C
9 banks
13.51.11
13.51.11C
1 bank
13.41.11
13.41.11C
2 banks
13.38.11
13.38.11C
2 banks
13.46.11
13.46.11C
3 banks
13.49.11
13.49.11C
5 banks
13.52.11
13.52.11C
6 banks
13.53.11
13.53.11C
4 banks
13.44.11
13.44.11C
Series R
Voltmeter / ammeter switches
Front mounting
VOLTMETER SWITCHES
3 phase
Rated current
Ie AC-21A (A)
IP
protection
Dimensions
mm x mm
0 RN
2 banks
0
20
48
54
40
72
25
for phase to phase
for 3 phase
for 1 phase
of two 3-phase lines and 3 phase to phase and 3 phase to phase
0 RS
2 banks
SN
45°
16
for 3
phase to phase
TN
0
45°
4 banks
RS
ST
S1T1
R1S1
TR
0
45°
14.16.11
13.16.11
13.16.11C
1.16.11
13.15.11
13.15.11C
1.15.11
0 RS
T1R1
ST
3 banks
0 RN
ST
SN
TR
TR
RN
ST
TN
TR
45°
45°
14.18.11
13.18.11
13.18.11C
1.18.11
13.17.11
13.17.11C
0 RS
3 banks
14.19.11
13.19.11
13.19.11C
Front mounting
AMMETER SWITCHES
For direct measure
without break
Rated current
Ie AC-21A (A)
IP
protection
Dimensions
mm x mm
0
5 banks
T
20
48
54
40
72
25
0
1 banks
R
S
90°
16
1 pole for 1
1 pole for 3
1 pole for 4
2 poles for 3
current transformer current transformer current transformers current transformers
0
1
3 banks
90°
13.14.11
13.14.11C
1.14.11
3
2
90°
13.20.11
13.20.11C
1
4 banks
1
4
5 banks
3
90°
14.22.11
13.22.11
13.22.11C
1.22.11
0
2
13.23.11
13.23.11C
3
1
2
90°
13.25.11
13.25.11C
1.25.11
DIN - RAIL mounting
45x54
45
64
80
VOLTMETER SWITCHES
Rated current
Ie AC-21A (A)
IP
protection
Dimensions
mm x mm
for 3 phase
to phase
0 RS
ST
45°
20
40
54x45
13.16.11D
0
TR
AMMETER SWITCHES
for 3 phase
and 3 phase to phase
RS
ST
TR
45°
13.18.11D
0 RN
SN
1 pole for 3
current transformers
TN
90°
13.22.11D
0
3
1
2
Series R
Accessories - handles and actuators
Standard handle
Black - lenght 40mm
Red - lenght 40mm
Black - lenght 50mm
Black standard handle
Lenght 35 mm
Lenght 37,5mm
Lenght 48mm
Lenght 71mm
Lenght 106 mm
Red standard handle
Lenght 37,5mm
Lenght 48mm
Lenght 71mm
Lenght 106 mm
Black handle Ø 30mm
Red handle Ø 37mm
Black handle Ø 37mm
Black handle Ø 41mm
IP40
IP65
Handle with locking device
black
red
Series
Code
13
13
13, 1
G1392N
G1392R
G1527N
13, 1
R32, R40
R32, R40
R50, R80
R125..R630
G3397N
L2-G3154N
L2-G3155N
RG3518N
RG3519N
R32, R40
R32, R40
R50, R80
R125..R630
13, 1
13, 1
13, 1
13, 1
R32, R40
R32, R40
R32, R40
L2-G3154R
L2-G3155R
RG3518R
RG3519R
G2536N
G2057R
G2057N
G3587N
L2-G2851N
L2-G2854N
L2-G2864N
L2-G2864R
Black lever
13, 1
Orange lever
13, 1
Orange lever
R32, R40
Black standard lever
R125..R630
Red standard lever
R125..R630
Actuator type N 72x72 mm yellow/red (for on - off switches with standard actuator)
13, 1
Actuator type N 67x67 mm yellow/red
R32, R40
Actuator type N 90x90 mm yellow/red
R50, R80
Actuator type N 135x135 mm yellow/red (with lever instead of handle)
R125, R250
Actuator type G 72x72 mm grey/black for on-off switches (0-1) with standard actuator 13, 1
Actuator type G 72x72 mm grey/black for change over sw. (1-0-2) with standard actuator 13, 1
Actuator type G 67x67 mm grey/black for change over sw. (1-0-2) with standard actuator R32, R40
Actuator type G 67x67 mm grey/black for on-off switches (0-1) with standard actuator R32, R40
Actuator type G 90x90 mm grey/black
R50, R80
Actuator type G 135x135 mm grey/black
R125, R250
Yellow legend plate 72mm, red handle for on-off switches
13, 1
Yellow legend plate 54mm, red handle for on-off switches
13
G1529N
G1529L
G2865L
RG3520N
RG3520R
G2391
LFS2-N-6-175
LFSR-N-8-175
LFSR-N-13-175
G3818
G2393
LFS2-G-6-325
LFS2-G-6-175
LFSR-G-8-175
LFSR-G-13-175
G2397
G2396
Actuator 54x54 mm neutral legend plate (without handle)
Actuator 72x72 mm neutral legend plate (without handle)
13, 1
13, 1
G3455
G3456
Actuator with guard 70x70 mm
(Complete of legend plate 0-1 Ø57 mm)
13, 1
G2433
Series R
Accessories
Series
13
13, 1
Code
G1683
G1590
Central mounting Ø 22mm key operated removable
in “0” position
13
G2389N
Central mounting Ø 22mm key operated removable
in “0” position
R32, R40
G3805 + LFC2-DD-001
Central mounting Ø 22mm handle operated
13
G2390N
Central mounting Ø 22mm handle operated
R32, R40
G3805 + LFC2-B-001
Installation tool for tightening the central fixture nut (Ø 22mm)
R32, R40
P3906
Panel hole adapter from Ø 30mm to Ø 22mm
13
G2326
Support for rear mounting
13
1
R50, R80
R125, R250 (max. 6 banks)
R125, R250 (max. 6 banks)
R400, R630
13, 1, R50, R80
G1720
RG1722
RG1724
RG1462
RG1474
RG1474
RG1761
Adapter plate for 4 fixing holes 68x68mm or 86x86mm
Adapter plate for 4 fixing holes 68x68mm or 104x104mm
R50, R80
R125..R630
REG3516
REG3517
DIN-rail mounting plate
13
G2535
Spacer for DIN-rail version (thickness 12,5 mm)
13
G2539
6,35 mm slip on terminal for screw terminals connection (M3,5)
13
1417
1
R32, R40
G2065
G3806
Gaskets to obtain IP54 degree of protection for basic version IP40
Extension supports for rear mounting
Lenght: 35..171mm
Device set to obtain a doorlock system from standard actuator
Series R
Accessories - Protections
Terminal covers
(3/4 poles)
front mounting
base mounting
Series
13, 1
R32
R40
R50
R80
R125
Code
P21853
RE32C4
RE40C4
RE50C4
RE80C4
RE125C4
13
1
R32
R40
R50
R80
R125
P21273
P20431
RA32C4
RA40C4
RA50C4
RA80C4
RA125C4
13
1
R32, R40
R50
R80
13
1
R32, R40
R50
R80
13
1
R32, R40
R50, R80
13
1
R32, R40
R50
R80
13
1
R32, R40
R50
13
1
R32, R40
R50
G1466
P10889
REG3180
REP10891
REP10892
G1466
P10889
REG3180
REP10891
REP10892
G1467
P10890
REG3181
REP10892
G1467
P10890
REG3181
REP10892
REP12792
G1468
P12481
REG3182
REP12792
G1468
P12481
REG3182
REP12792
Flexible shield
1 bank
2 banks
3 banks
4 banks
5 banks
6 banks
Series R
Accessories
Series
R32, R40
Front installation shaft
Lenght 34 mm Termoplastc (standard)
Lenght 34 mm Metal
Lenght 34 mm Termoplastic
(to turn position 90° anti-clockwise)
Lenght 34 mm Termoplastic
(to turn position 90° clockwise)
Base installation shaft
Lenght 44 mm Termoplastic (standard)
Lenght 44 mm Metal
Lenght 52 mm Termoplastic
Lenght 52 mm Metal
Lenght 57 mm Termoplastic
Modular shaft extension
2 overlapping modules 24 mm
(Max 4 modules - total lenght 96 mm)
L2-G3380
L7-G3688
G3189
G3186
R32, R40
LA2-G2830
L7-G3687
LA2-G3194
L7-G3707
LA2-G3195
LA2-G2853
R32, R40
Metal shaft extension
Lenght 110..235 mm
Lenght 230..350 mm
With yellow insert for on-off switches “0” h9
Insert for metal extension
With red insert for on-off switches “0” h12
R32, R40
LA2-G3393
LA2-G3394
R32, R40
Grey insert to obtain a different start position “0”
LA2-G3398
LA2-G3399
R32, R40
Clutch for doorlock
“0” in position h12
“0” in position h9
R32, R40
Reducer for front installation shaft
R32, R40
Termoplastic enclosure - front actuator with guard
Code
P25394
P26747
P3907
Series
13
banks
2
Code
G3150
122x97 h 79mm
13
1
6
6
G2401
113x95 h 85mm
13
1
5
5
G2403
130x95 h 91mm
13
1
4
4
G2533
78x60 h 61mm
IP54
Termoplastic enclosure - side operated lever
IP55
Metal enclosure - side operated lever
IP55
Termoplastic enclosure - front actuator
IP54
Series R
Accessories - Legend plates
Central mounting Ø 22mm
29,5x41mm
OFF ON
1
0
1
P22921
54x54mm
P24447
0
P22850
P24143
P24720
1 0 2
OFF
1
0
2
0
MAN
0
NEUTRAL
NEUTRAL IN SILUMIN
AUT
ON
P24894
P24906
P24892
P24907
P24890
P24897
RS
ST
0 TR
NEUTRAL
Series 13,1
72x72mm
0
OFF
1
1
P20688
0
2
2
3
AUT
P20673
P20706
1
5
P20772
1
2
P20699
ST
TR
P20704
2
3
4
P20742
2
3
3
P20701
6 5 4
P20733
0
3
SN
TR
6
5
1
4
0 RN
ST
P20764
2
P22456
RS
0 1
2
3
4
3
0 RS
P3814
0 1
2
3
4
2
0
0
MAN
P3813
0 1
1
1
0
ON
TN
1
2
P20686
P20690
P20830
NEUTRAL
Ø 57mm
0
1
0
2
1
P25175
P22714
P10433
NEUTRAL
Series 13 - Front plates (DIN-RAIL type) 45x54 mm
Handle operated
0
1 0 2
OFF
1
P25103
0
P25138
RS
RS
0
ST
ST
0 TR
P25100
Key operated
TR
0
3
SN
AUT
P25092
P25120
P25105
P24919
1
2
P25102
1 0 2
OFF
MAN
0
NEUTRAL
AUT
ON
P25053
P25088
RS
RS
ST
ST
0 TR
0
0
RN
0 TN
1
0
MAN
ON
P25050
TR
0
3
SN
0 TN
P25042
P25070
P25055
P24914
0
RN
P25052
1
2
NEUTRAL
Series R
Mounting examples
Series R 32/40
Base mounting type
Series R 50/80/125…630
Base mounting type
Series R
Front mounting type
The drawings represents
only some mounting types
for additional details, please
see the relevant instruction sheets
Series R
Technical informations
ALTERNATING CURRENT (IEC / EN 60947-3)
Rated operational voltage Ue
Rated isolation voltage Ui
Rated impulse withstand voltage Uimp
Dielectric test voltage for 1 min.corresponding to Ui
Rated trequency
Conventional free air thermal current Ith
Conventional enclosed thermal current Ithe
Power loss by 1 pole at Ithe
Rated operational current Ie
AC-1
Non inductive or slightly inductive loads
AC-21A Switching of resistive loads with slight overload
Rated power Pe
AC-23A Frequent switching of motors
or other higly inductive load
AC-3
Squirrel - cage motors: starting and stopping
of running motors
AC-4
Squirrel - cage motor starting, reversing,
electric breaking, inching
Rated breaking capacity (AC-23A)
cos ϕ 0,45 per Ie ≤ 100A
cos ϕ 0,35 per Ie > 100A
Short circuit characteristic
Conditional rated short-circuit current
Max. fuse rated current (fuse type gG/gL)
Rated short-time withstand current Icw (1s)
Rated short-circuit making capacity Icm
AC-15
Control of AC electromagnetic loads
DIRECT CURRENT (IEC / EN 60947-3)
DC-20A Rated operational current Ie
Rated operational current Ie
DC-1
Non inductive or slightly inductive loads
DC-21A Switching of resistive loads with slight overloads
Rated power
DC-23A Control of high inductive loads series and shunt motors
The rounded values correspond to
the numbers of poles to connect in series
Rated operational current Ie
DC-13 Control of electromagnets
L/R = 40 ms
DC-13
Control of DC electromagnetic loads
V
V
kV
kV
Hz
A
A
W
Series
14
440
440
4
2,5
50/60
16
16
0,34
13
690/600
690/600
6
2,5
50/60
25
25
0,3
A
16 (400V)
25
230 V
400 V
690 V
230 V
400 V
690 V
230 V
400 V
500 V
kW
kW
kW
kW
kW
kW
kW
kW
kW
4
5,5
2,2
3
-
5,5
7,5
11
4
5,5
7,5
2,2
3
3
230 V
400 V
690 V
A
A
A
120
90,4
-
176
176
100
400/415 V
kA
A
kA
kA
5
16
0,32
A300
5
25
0,4
1,5
IEC-EN / UL-CSA
IEC / UL-CSA
IEC
690 V
24 V
48 V
60 V
110 V
220 V
24 V
48 V
60 V
110 V
220 V
380 V
500 V
A
A
20
10
V max per polo
60
kW
kW
kW
kW
kW
A
A
A
A
A
A
A
0,3 0,4 0,6 0,8 1,2 10
5
3
1,3
0,5
0,3
0,2
Q300
Series R
Technical informations
1
690/600
690/600
6
2,5
50/60
25
25
0,6
R32
690/600
690/600
8
2,5
50/60
32
32
0,8
R40
690/600
690#/600
8#
2,5
50#/60#
45#
45#
1,4
R50
690/600
690#/600
8#
2,5
50/60
50#
50#
1,5
R80
690/600
690#/600
8#
2,5
50/60
80#
75#
2,8
R125
690/600
690/600
8
2,5
50/60
125
120
5,3
R250
690/600
690/600
8
2,5
50/60
250
200
10
R400
690/600
690/600
8
2,5
50/60
400
315
13,6
R630
690/600
690/600
8
2,5
50/60
630
500
25,5
25
32
40#
50#
75#
120
200
250
315
7,5
11
15
5,5
7,5
11
2,2
4
4
11
18,5
22
7,5
15
18,5
5,5
7,5
7,5
11#
22#
22#
7,5#
18,5#
18,5#
5,5
7,5#
11
15#
22#
30#
11#
18,5#
22#
7,5
11
15
18,5#
30#
37#
15#
22#
30#
11
15
18,5
30
45
55
22
30
37
15
22
30
37
55
75
30
37
45
18,5
30
37
204
172
136
296
280
196
296#
336#
196#
400#
336#
260#
484#
544#
316#
780
656
456
936
804
616
5
25
0,5
1,5
5
35
0,8
2
5#
40#
0,8
2
5#
50#
1#
2,5#
5#
63#
1,5#
3#
6
100
2,4
5
8
160
4
7
12
250
5
10
15
315
6,5
15
25
16
32
25
40
25
50
40
75
63
120
100
200
200
60
60
60
60
60
48
42
0,3 0,3 0,5 0,5 1 1 2 2 2,2 2,2 14
16
7
8
4,2
4,8
1,8
2
0,5
0,6
0,4
0,4
0,3
0,3
#
Values approved by IMQ
0,3 0,5 1 2 2,2 16
8
4,8
2
0,6
0,4
0,3
0,7
1,4
2
3
6
1
2
2,7
4
8
Series R
Technical informations
UL / CSA
General use 1 phase/2 poles, 3 phase/3 poles
Rated current
Heavy Pilot Duty (AC)
Standard Duty (DC)
Rated operational power
Across the line AC motor starting
DOL-Rating
1 phase 2 poles
Series
3 phases 3 poles
ENVIROMENTAL DATA
Ambient temperature:
1
16
A
20
A 600
P 600
120 V
240 V
480 V
600 V
120 V
240 V
480 V
600 V
HP
HP
HP
HP
HP
HP
HP
HP
1,5
3
5
5
2
5
10
10
3
6 7,5
6
12
15
-25°C a +60°C
-40°C a +80°C
Milion of operations
Screw driver size
recommended torque (Nm)
APPROVALS
CE-confirmal
CSA (Canada)
IMQ (Italy)
UL-Listed (USA)
UR (USA)
• Approved as a result of test passed
Only CSA approval
13
600 V
Code designation
Code designation
Operation:
Storage:
MECHANICAL DATA
Protection class according to IEC/EN 60529
Actuators
Switch bodies
Mechanical life
Terminal sizes according to IEC/EN 60947-1 gauge form
Min./max. wire cross section
Fine strands
Solid or stranded
Max. wire gauges according to UL/CSA (solid/stranded)
Terminals
14
mm2
mm2
AWG
Type
Thread
2/1
0,6
IP40
IP00
1
IP40..IP55
IP00
2
IP40..IP55
IP00
1,5
A2
0,75/2,5
0,75/2,5
14/14
screw
M3
3/2
1,2
A3
1/2,5
1/4
10/12
screw
M3,5
3/2
1,2
A3
1/2,5
1/4
10/12
screw
M4
3/2
1,8
•
•
•
•
•
•
•
For CSA 220V e 440V Only UL approval
Series R
Technical informations
R32
R40
R50
R80
R125
R250
R400
R630
32
40
50
63
115
200
250 (315A at 480V)
315
2
5
7,5
10
5
7,5
20
20
2
5
10
15
5
10
25
25
3
7,5
15
20
7,5
15
30
40
7,5
15
30
35
15
30
60
75
10
20
40
50
25
50
75
100
IP66
IP00
1
IP66
IP00
0,5
IP66
IP00
0,5
embedded hexagon
embedded hexagon
embedded hexagon
M10
hexagon 8 mm
10
M12
hexagon 10 mm
14
M14
hexagon 12 mm
19
Operation:
Storage:
5
10
20
25
10
20
40
50
-25°C a +60°C
-40°C a +80°C
IP66
IP20
1
IP66
IP20
1
IP66
IP00
1
IP66
IP00
1
IP66
IP00
1
A5
2,5/6
2,5/10
8/10
screw
M4
3/2
1,8
A5
2,5/6
2,5/10
8/10
screw
M4
3/2
1,8
A5
2,5/6
2,5/10
8/10
screw
M5
3/2
2
A5
2,5/16
2,5/25
4/6
screw
2xM4
3/2
1,2
B7
1,5/35
1,5/50
1/2
screw
2xM6
4/2
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Series R
Dimensions - Fixing holes
Front mounting
H
A
C
D
F
B
Series
14
13
1
R32
R40
R50
R80
R125
R250
R400
R630
E
L
1
37
35
2
32
50
48
3
62
60
L no. of banks
4
54
75
73
5
87
85
6
100
98
7
112
110
8
125
123
41
58,5
76
93,5
111
128,5
146
163,5
64
51
60
69
87
87
114
105
141
123
168
141
195
159
222
177
249
88
83
113
143
173
203
233
263
293
113
143
173
233
233
323
293
413
353
503
413
593
473
683
533
773
G
A
B
C
D
E
Ø 35
Ø 47
Ø59
72
38
28
Ø 61
67
34
45
Ø 80
90
49
48
23,5
54 or 72 28 or 32
72
32
130
55
118x102
118x191
A
1,5
135
-
120
70
118x180
42
A
C
24
Ø 9,5
B
C
Ø 3,2
BODIES/ACTUATORS
Series 13, 1, R32, R40, R50, R80
13
1
R32
R40
R50
R80
H max
4
36x36 o 48x48
A
G
14
B
Series
F
(mm x mm)
20
BODIES/ACTUATORS
Series 14 fixing
C
100
BODIES/ACTUATORS
Alternative fixing
for series 13, 1, R32, R40
32
9,5
12
3,2
33
5,3
46
5,3
BODIES/ACTUATORS
Series R125..R630
Central mounting Ø 22mm
1…6mm
+0,2
3,2 0
+0,4
24,1 0
Ø 30
C
+0,4
22,3 0
A
Series
13
R32
R40
B
L
B
C
2
82
3
94
L N° of banks
4
107
A
1
69
5
119
6
132
7
144
8
157
36
26
Ø 47
86
103,5
121
138,5
156
173,5
191
208,5
41
28
Ø 61
Series R
Dimensions - Fixing holes
Base mounting
S
1…6mm
A
C
A
C
D
F
L
T
B
Y
E
L
G
X
B
Series
13
1
R32
R40
R50
R80
R125
R250
R400
R630
1
43
42
2
56
55
L no. of banks
3
68
67
4
81
80
if Y min
then X
≥
if Y max
then X
≥
29
75
150
29
75
150
42,5
60
77,5
95
-
-
-
-
59
68
-
77
95
95
122
113
149
75
150
78
150
123
153
183
183
243
-
-
71,5
220
77,5
220
IF S then T
MIN.
2,5
150
IF S then T
MIN.
9,5
90
N
H
I
L
L
M
Q
O
M
ACTUATORS
ACTUATORS
P
R
BODIES
ACTUATORS
Series
A
B
C
54 o 72
72
28
32
51x51
64
28
88
45
D
E
72
38
67
34
92
49
F
G
H
I
L
58
32
33
9,5
BODIES
M
N
O
36
36
-
-
85
85
37
132
P
Q
R
70
15
(mm x mm)
13
1
R32
R40
R50
R80
R125
R250
R400
R630
78x55
102x102
-
-
36 o 48
3,2
17
12
M4
68
130
55
57x148
135
-
120
70
5,3
20
M5
Diagrams
09 3 Poles dahlander switch
14 Ammeter sw. for direct
measure without break
Y-T8
7
3-4
1-2
Elements
Contact
2 4
X
X
0
0 1
1
90°
Pos.
3
4
1
2
3
Y-T8
Y
8
15-16
13-14
11-12
3
9-10
7-8
2
5-6
3-4
1
1-2
0 1
1
Pos.
90°
3
4
1
2
04 4 Poles on-off switch
Element
1 3 5 7
L1
L2
L3
1
16 14 3
X-T7
X X
X X
X
X
X
X
X X
X
4
0
4 W-T3
45°
90°
Contact
Contact
Element
7
8
13
V-T2
X
15
16
13
14
4
19-20
17-18
15-16
13-14
11-12
9-10
7-8
5-6
3-4
1-2
2
X
X
X
X
X
X
X
X
X
S
R
5
Pos.
0
R
T
S
3
V
7
7
8
3
4
0
2
Positions
10
6
0
1
1 0 2
3
2
Pos.
4
4
06 2 Poles changeover switch
3
2
X
7
X
1
1 0 2
0
3
2
Pos.
8
6
1
4
Elements
Element
1
7-8
5-6 X
3-4
1-2 X
Contact
2
5
2
45°
2
45°
25
1
X
23
X
X
19
X
15
X
X
X
X
X
X
X
X
X
X
X
X
2 0 1 0 1 0 2
7
11
7
X
1 0 2
Y
0
5
3
2
Pos.
4
2
45°
4
3
08 3 Poles reversing switch
2
Contact
Element
11
X
X
X
1 0 2
Pos.
11 7 3
1
0
7
12
8
3
2
45°
2
1
Elements
11-12 X
9-10
7-8 X
2
5-6
3-4
1
1-2 X
3
Z-T9 7
Y
45°
90°
6
1
0
8
19-20
17-18
15-16
13-14
11-12
9-10
7-8
5-6
3-4
1-2
2
Y-T8
12
V-T2
X X
X X
X X
X
X
X
X
X X
X
10 W-T3
5
X-T7
1
L1
L2
L3
2
Positions
X
X
X X
X
Y 0 Y
Positions
0
TR
12
10
TR
A
11-12
9-10
7-8
2
5-6
3-4
1
1-2
X
X
X
X
X
X
3
8
1
X
X
1
X
X
X
0
1
2
2
X
0
3
3
Positions
1
2
90°
23 1 Pole ammeter switch for 4 current transformers
L1
L2
L3
L4
4
12
2
6
7 15
A
15
X X
7
12
6
10
X
X
4
7
X X
2
X X
0
0
4
2
Positions
9
N
L1
L2
L3
SN
TN
12
16
X
2 12 8 4
45°
11-12
X
9-10 X
7-8
2
5-6
X X
3-4 X X
1
1-2
11
X
3
4
2
14
X
V
8
5
3
15
X X
0 RN
RS
ST
12
9
15
18 Voltmeter switch 3 phases and 3 phase to phase
11
7
45°
15-16
13-14
11-12
9-10
7-8
5-6
3-4
1-2
15
X
X
V
19 15 3
19
X X
4
3
4 8
Contact
Contact
Element
3
4
3
12
8
ST
R1S1
Positions
2
0 RS
T1R1
S1T1
5
X
X
12
10
X
6
3
0
7
10
1
8
17 Voltmeter switch 3 Phase to phase of 2-3 phases lines
9
U-T1
11
X 4 2 8 6 12 10
7
X X
X
X X
0
3
3
1
Pos.
X
X
X
X
X
7
45°
7-8
5-6
3-4
1-2
2
12 Star-Delta reversing switch
07 3 Poles changeover switch
11-12
3
9-10 X
7-8
2
5-6 X
3-4
1
1-2 X
23 19 3
X-T7
TR
V
R1S1
S1T1
T1R1
X
X
X
V-T2
Elements
3-4
1-2 X
Contact
Element
1
27-28
25-26
23-24
21-22
19-20
17-18
15-16
13-14
11-12
9-10
7-8
5-6
3-4
1-2
Z-T9
9
0
12
9
X
8
X
0
X
X
RN
SN
TN
7
15
5
45°
W-T3
RS
ST
TR
05 1 pole changeover switch
25
RS
ST
TR
2
4
TR
ST
RS
0
1
0
2
Contact
90°
0
Elements
2
1
Contact
1
Pos.
U-T1
4
ST
Contact
3
1
3
0 RS
L1
L2
L3
0
A
1
L1
L2
L3
Elements
Y-T8
6
2
3-4
X X
1-2 X X
Positions
15-16
13-14
11-12
3
9-10
7-8
2
5-6
3-4
1
1-2
4
2
X
4
Elements
8
5
16 3 Phase to phase voltmeter switch
Elements
0
0 1
7
Contact
Element
Contact
2
1
11 Pole changing reversing switch
X
X
X
X
2
L1
1
6
2 4 6 8
7-8
5-6
3-4
1-2
1
Positions
9
X X X
X
X
X
0
0
22 1 Pole ammeter switch for 3 current transformers
45°
7-8
5-6
3-4
1-2
2
1
4
3
0 Y
90°
T
SN
8
8
X
X X
90°
X
X
X
Positions
TN
X
1
X
X
X
15 3 Phase voltmeter switch
0
10
0
0 RN
7
X X
20 1 Pole ammeter switch for 1 current transformer
X
X
X
0
12
11
RS
ST
TR
3
3 11 19
5
4
Pos.
15 7
11-12
9-10 X
7-8 X
2
5-6
3-4
1
1-2
5
L4
L5
L6
2
0
X
X
4
3
1 0 2
10 Star-Delta switch
2 4 8
1
8
10 8 2 12
45°
3
16 12 2
5
Z-T9 5
7-8
5-6
3-4
1-2
14
7
U-T1
2
13
X
X
X
1 3 7
03 3 Poles on-off switch
16
RN
1 3
X
X
15
12
Contact
90°
15-16
13-14
11-12 X
3
9-10 X
7-8
2
5-6
3-4
1
1-2 X
4
0 RS
TR
11
Elements
4
RN
N
L1
L2
L3
ST
L1
L2
L3
Contact
Pos.
02 2 Poles on-off switch
1
16
1
V
Elements
3
1
11
16 14 3
X-T7
RN
SN
TN
Contact
0
5
A
Elements
Elements
0 1
8
V-T2
45°
Contact
X
Z-T9
2
4
L1
L2
L3
4
Element
1
3-4
1-2
0
W-T3
13
5
1
4
Contact
15
19 Voltmeter switch 1 phase and 3 phase to phase
19
Contact
U-T1
Contact
3
Contact
01 1 Pole on-off switch
Element
SERIES R (13, 1)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
2
X
3
Positions
4
1
2
4
3
90°
Diagrams
7
8
5
6
4
0 M A
Self-input 5
M
A
Impulse ahead 3
Impulse behind 1
45°
2
7-8
5-6 X X
3-4 X
1-2
Contact
Elements
1
A M 0 M A
1
Positions
U1
L1
L2
Z1
11
5
Z2
X X
X X
X
Auxiliary winding
11-12
9-10
7-8
2
5-6
3-4
1
1-2
Contact
Elements
X X
X X
4
3
2
11
12
9
10
X
X
1
Positions
2
5
U
L1
L2
10 4
4
3
Contact
Elements
X
X
9
10
7
X
X
1 0 2
1
0
4
3
2
Pos.
1
Elements
X
X
X
X
1
15
16
11
12
14
X
X
X
10
X
7
X
X
1
0
3
2
Pos.
12
28
10
9
5
4
3
7
8
6
1
1 2 3 4
4
2
3
4
Pos.
45°
2
16
7
1
16
14
11
12
10
8
6
4
Positions
2
3
2
3
4
2
45°
X X
15
X X
X X
X X
X
X
X
X
X X
X
12
X
X
X
X
X X
X
10
8
7
5
4
3
Y 0 Y
Positions
57 1 Pole step sw. 3 positions + 0
0
876
2
1
19
1
4
Pos.
45°
30°
16
19-20
X
17-18
X
15-16
X
13-14
X
11-12
X
9-10
X
7-8
X
5-6
X
3-4
X
1-2 X
14
12
10
8
4
1
18
12
10
12 1 2
11
3
10
4
9
5
876
6
5
14
10
7
1
4
2
3
4
Pos.
45°
4
3
8
6
2
1
2
45°
11
12
10
X
8
6
1 2 3 4 5 6
4
Positions
2
1
3
45°
7-8
5-6
3-4
1-2
X
7
X
8
X
6
0 1 2 3 4
4
Pos.
2
X
59 1 Pole step sw. 5 positions + 0
16
0 1
14
20
1 2 3 4
24
6
12
2
2
53 1 Pole step sw. 12 positions
2
16
4
1
Pos.
0
2
8
8
X
0 1 2 3
4
Positions
23
X
X
58 1 Pole step sw. 4 positions + 0
1 2 3 4 5 6 7 8 9 10
22
18
1
2
8
15
7-8
5-6
3-4
1-2
2
6
20
24
45°
18
10
22
3
20
12
2
Contact
Pos.
1
Elements
1 2 3
5
4
18
4
2
3
3
6
19-20
17-18
15-16
13-14
11-12
3
9-10
7-8
2
5-6
3-4
1
1-2
22
20
6
1 2 3 4
11-12
X
9-10
X
7-8
2
5-6
X
3-4
X
1
1-2 X
19
24
1 2 3 4 5 6
14
3
7-8
5-6
X
3-4 X
1-2
X
L1
L2
L3
19 15 3
X-T7
15°
30°
26
3
4
5
4
2
45°
23-24
X
21-22
X
19-20
X
17-18 X
15-16
X
13-14
X
11-12
X
9-10 X
7-8
X
5-6
X
3-4
X
1-2 X
6 5 4
8
13
V-T2
4 W-T3
Y 0 Y
52 1 Pole step sw. 10 positions
8
6
15-16
X
13-14
X
11-12
X
9-10 X
7-8
X
5-6
X
3-4
X
1-2 X
1
4
2
X
49 1 Pole step sw. 6 positions
2
45°
38 1 Pole step switch 3 positions
Contact
3
2
23
6
2
Elements
2
X
1
3 9
1
4
Z-T9 5
32
23
Y-T8
15 7
30
48 3 Poles step sw. 4 positions
A M 0 M A
7
2
3
2
45°
1 0 2
5
V1 U1 V
11-12
9-10
7-8
2
5-6
3-4
1
1-2
1 2
5
4
8
3
34
X
37 Reversing sw. single phase motor + capacitor
3
1
7-8
X
5-6
X
3-4
X
1-2 X
Elements
U2
45°
3
6
15
1
9
M
A
8
6
7
Pos.
36
47 2 Poles step sw. 4 positions
10 12
0
7
X
7
Contact
Contact
2
X
32 Single phase reversing sw. + aux. winding
M
A
X
X
46 1 Pole step sw. 4 positions
X X
Elements
Elements
1
Elements
0
6
12
10
Pos.
15-16
13-14
11-12
9-10
7-8
5-6
3-4
1-2
Elements
M
A
4
2
30 Changeover sw. for remote control reverser
11
X
45 4 Poles changeover switch
3
Pos.
X
X
8
14
5
U-T1
35
4
2
30°
23-24
X
21-22
X
19-20
X
17-18
X
15-16
X
13-14
X
11-12
X
9-10
X
7-8
X
5-6
X
3-4
X
1-2 X
1 2 3 4 5 6 7 8 9 10 11 12
Positons
5
4
2
3
11-12
9-10
7-8
2
5-6
3-4
1
1-2
45°
3
9
X
10
X
8
X
X
6
0 1 2 3 4 5
4
Positions
2
X
60 2 Poles step sw. 3 positions + 0
0
1
2
3
11-12
9-10
7-8
2
5-6
3-4
1
1-2
3
Elements
Contact
Elements
X X
X X
X
16
14
Contact
2
1
7-8
5-6
3-4
1-2
Elements
Avv. ausiliario
45°
X
X
16
13
55 Star-Delta reversing switch
45°
35-36
X
33-34
X
31-32
X
29-30
X
27-28
X
25-26 X
23-24
X
21-22
X
19-20
X
17-18
X
15-16
X
13-14 X
11-12
X
9-10
X
7-8
X
5-6
X
3-4
X
1-2 X
16 14 3
15
0 Y
Contact
1
Z2
2
Elements
9
U2
M
A
4
Positions
Contact
5 7
1 2 3 4 5 6
3
2
45°
15
15-16
13-14
11-12
3
9-10
7-8
2
5-6
3-4
1
1-2
4
1
2
6 5 4
44 4 Poles step switch 2 positions
L1
L2
4
1
9
90°
2
8
Contact
Z1
8
Pos.
4
1
3
2
U1
3
2
10
Contact
0
3
Positions
1
3
12
51 3 Poles step sw. 6 positions
6
1 2
4
14
11
Contact
X
8
15-16
X X
13-14
X X
11-12
X
9-10
X
7-8 X X
5-6 X X
3-4
X X
1-2
X
6
10
7
16
L1
L2
L3
X-T7
18
Elements
X
12
4 W-T3
15°
30°
20
Elements
X
11
11-12
X
9-10 X
7-8
X
2
5-6 X
3-4
X
1
1-2 X
2
1
3
29 Single phase motor switch + aux. winding
0
2
0 Y
22
8
13
V-T2
24
Elements
X
X
6
4
Elements
X
2
3
2
5
2
1
3
1 2
Contact
X
4
6
1
Elements
Elements
0
8
43 3 Poles step switch 2 positions
X
ElementS
2
1
7
Pos.
Contact
3
1
Contact
4
X
23-24
X
21-22
X
19-20
X
17-18
X
15-16
X
13-14 X
11-12
X
9-10
X
7-8
X
5-6
X
3-4
X
1-2 X
5
7-8
X
5-6 X
3-4
X
1-2 X
Y-T8
15 7
Z-T9 5
45°
23
2
Pos.
Contact
5
Contact
6
12
6 5 4
4
Contact
11
23-24
21-22
X
19-20
X
X
17-18
15-16
X
X
13-14
11-12 X
X
9-10
7-8
5-6
X
3-4
1-2
X
3
2
6
Elements
14
U-T1
2
3
1
1 2
42 2 Poles step switch 2 positions
2
13
1
Elements
20
54 Star-Delta switch
50 2 Poles step sw. 6 positions
Contact
19
3-4
X
1-2 X
Elements
5 2
1
Contact
13 14
12
Contact
11 20
41 1 Pole step switch 2 positions
A
19
Contact
L1
L2
L3
Contact
25 2 Poles ammeter switch for 3 current transformers
45°
12
X
9
X
X
X
10
8
X
6
X
0 1 2 3
Pos.
3
4
2
Diagrams
6
X
0 1 2 3 4
4
Pos.
2
23
24
22
45°
Contact
Elements
X
8
7
6
5
20
23-24
21-22
19-20
17-18
15-16
13-14
11-12
9-10
7-8
5-6
3-4
1-2
9
4
3
2
18
X
1
X
15
X
16
14
X
X
10
X
7
X
8
X
6
0 1 2 3 4
4
X
2
Pos.
4
Contact
Elements
36
11
X
12
10
X
8
X
Positions
2
90°
X
26
X
23
X
24
X
22
X
20
X
18
X
X
16
X
14
X
11
X
6
X
0 1 2 3 4 5 6
4
Positions
2
2
1
5-6
7-8
1-2
3-4
X
5
6
1
2
3
4
X
X
1
0 1
0
Pos.
90°
1754 4 Poles on-off switch
Contact
Elements
X
6
7
X
1
0
1
2
Pos.
45°
2
3
3503 3 Poles changeover switch
X
8
X
X
6
3
0 1 2 3 4 5 6 7
4
2
Positions
Y-T8
15 7
60°
X
X
X
X
X
X
8
4 W-T3
L1
L2
L3
2
1
5-6
7-8
1-2
3-4
1
X
X
X
X
1
0 1
0
90°
Pos.
5
6
7
8
1
2
3
4
1 3 5 7 9 11
2 4 6 8 10 12
9-10
3
11-12
5-6
2
7-8
1-2
1
3-4
X
X
X
X
X
X
1
0 1
0
Pos.
90°
9
10
11
12
5
6
7
8
1
2
3
4
3 1
16 14 3
X-T7
16
13
14
7
8
0
5
X
X
1 0 2
1
0
Pos.
2
60°
4
7
8
1
2
3
2
2
13-14
15-16
9-10
11-12
5-6
2
7-8
1-2
1
3-4
4
3
8
1
X
X
X
X
X
15
16
9
10
11
X
X
5
7
8
1 0 2
1
2
X
3
Pos.
2
3 1 5
3
45°
5-6
7-8
1-2
3-4
2
4
X
5
X
X
0 1 2 3
1
Pos.
3
4
5271 1 Pole step switch 4 positions + 0
1
1
X
1 0 2
2
0
1
2
Pos.
45°
4
45°
2
3
5-6
7-8
1-2
3-4
2
3252 2 Poles changeover switch
3 1 7 5
Pos.
2
2
1
5-6
7-8 X
1-2
3-4 X
6
X
5
X
1
6
1
2
1
0
1
2
45°
Pos.
9
6
10
10
11
X
5
X
1 0 2
Pos.
6
7
1
0
1
2
45°
1
3
8
Pos.
3
3 7 5 11 1
45°
12
2
X
0 1 2 3 4
4
5
2
3 1 7 5 11 9
9-10
11-12 X
5-6
2
7-8 X
1-2
1
3-4 X
5
7
3
3253 3 Poles changeover switch
3
X
X
X
3
0
1 0 2
8
X
5281 1 Pole step switch 5 positions + 0
7
3 1 7 5
3
0
1
16
0
2
1-2
3-4 X
10
13
5261 1 Pole step switch 3 position + 0
5
3
10
11
60°
1
3251 1 Pole changeover switch
15
10
3 1 5 7 11 9 13 15
2 4 6 8
10
X
8
9
X
3504 4 Poles changeover switch
12
X
13
V-T2
9-10
3
11-12 X
5-6 X
2
7-8
1-2
1
3-4 X
1 3 5 7
16
X
Y 0
5
X
2
2 4 6
X
X
X
X
10
11
X
3 1 5 7 11 9
1756 6 Poles on-off switch
45°
X
X
9
X
X
1 3 5
8
X
Z-T9 5
15-16
13-14
11-12
3
9-10
7-8
2
5-6
3-4
1
1-2
X
10
X
0
4
2
4
12
X
U-T1
Y
1
3
1753 3 Poles on-off switch
28
70 Star-Delta switch
X
4
0
30
X
6
0 1 2 3 4 5 6
1
0 1
Pos.
14
32
X
X
X
14
34
X
15-16
13-14
11-12
9-10
7-8
5-6
3-4
1-2
Elements
45°
Elements
11-12
9-10
7-8
2
5-6
3-4
1
1-2
1
3
35-36
33-34
31-32
29-30
27-28
25-26
23-24
21-22
19-20
17-18
15-16
13-14
11-12
9-10
7-8
5-6
3-4
1-2
7 0 1
6
2
5
3
4
2
0 1
2
3
35
45°
67 1 Pole step sw. 7 positions + 0
3
4
2
3
12
X
X
64 1 Pole step sw. 6 positions + 0
6
5
4
10
15
X
1 0 2
Contact
X
8
2 4
X
X
Elements
7
1
3
6
5
1 3
Contact
10
X
X
90°
Elements
X
Pos.
0 1
12
X
1-2
3-4
Contact
X
X
1
Elements
14
2
4
2
2
Contact
Contact
Elements
0
1
4
Positions
16
63 3 Poles step sw. 4 positions + 0
3
0 1 2 3 4 5 6
13-14
15-16
9-10
3
11-12
5-6
2
7-8
1-2
1
3-4
4
6
Elements
15-16
13-14
11-12
3
9-10
7-8
2
5-6
3-4
1
1-2
15
2
8
X
Contact
45°
1
1752 2 Poles on-off switch
Elements
3
4
4
X
X
66 3 Poles step sw. 6 positions + 0
2
5
10
1
4
6
X
6
13
1
0
12
Contact
0
X
0 1
Elements
62 2 Poles step sw. 4 positions + 0
11
Contact
Pos.
1
14
X
X
1-2
3-4
Elements
2
X
1
Contact
4
0 1 2 3
16
Elements
2
18
X
Contact
3
6
X
X
Elements
8
X
X
5
2
2
2
9-10
3
11-12
5-6
2
7-8
1-2
1
3-4
Contact
4
X
X
1
22
20
Contact
10
21
Elements
12
9
X
X
Contact
11
23-24
21-22
19-20
17-18
15-16
13-14
11-12
9-10
7-8
5-6
3-4
1-2
Elements
14
Contact
Contact
Elements
1
X
X
6
13
Contact
2
X
3 1 7 5 11 9 15 13
1751 1 Pole on-off switch
45°
24
16
X
Elements
3
X
2
3
4
Contact
4
19-20
17-18
15-16
13-14
11-12
9-10
7-8
5-6
3-4
1-2
6
5
Contact
5
45°
3254 4 Poles changeover switch
SERIES R (R32..R630)
0 1
Elements
3
65 2 Poles step sw. 6 positions + 0
20
2
Contact
1
Elements
0
Elements
61 3 Poles step sw. 3 positions + 0
X
11
X
X
5
X
X
7
0 1 2 3 4 5
1
Positions
3
12
Diagrams
0
0 1
1
1
Pos.
2
45°
02 2 Poles on-off switch
1 3
6
5
8
1
1 0 2
2
1
Pos.
7303 3 Poles reversing switch
1-2
3-4
U1
0
0 1
1
Pos.
45°
1
2
3
4
Contact
Elements
TR
12 6 2
W1
11
X
5
X
X
2 4 6
12
2
6
1
2
1 0 2
3
Pos.
5-6
7-8
1-2
3-4
X
5
6
X
X
0
0 1
1
Pos.
45°
1
2
3
4
04 4 Poles on-off switch
1
13
RS
6
1
2
45°
1
2
3
4
4 2
8
7503 Star-Delta switch
W2
U1
6 14
0
1
8
W1 1
5
16
V2
8 U2
1
1
1-2
3-4 X
1 0 2
1
0
1
2
Pos.
2
1
60°
Contact
Elements
0
13
14
15
16
2
1
5
6
1
2
8
Y
5-6
7-8 X
1-2
3-4 X
Contact
X X
X X
X
X
X
X
X X
X
Elements
13-14
15-16
9-10
3
11-12
5-6
2
7-8
1-2
1
3-4
4
X
5
1 0 2
1
0
1
2
Pos.
4
V2
0
Contact
Elements
X
X
X
X
X
X
X
X
X
5
16
8 U2
V1
13
14
15
16
5
X
X
Y 0
Pos.
13 15 2
6
8
1
2
Contact
W1 1
9-10
3
11-12 X
5-6
2
7-8 X
1-2
1
3-4 X
L1
L2
L3
X
4
Positions
3
N
L1
L2
L3
0 RS
12 6 4 10
45°
9-10
3
11-12 X
5-6 X
2
7-8
1-2
1
3-4
10
9
X X
12
X
6
X
X X
0
3
Positions
4
L1
L2
L3
5
9
10
10
12
4
8
A
15
13
5
10
X
5
6
1
2
X
1 0 2
Pos.
9
X
8
1
0
5
13-14
15-16
9-10
3
11-12
5-6
2
7-8
1-2
1
3-4
4
2
45°
4
X
X
X
X
X
8
X
X
X
X
X
4
X
0
1
X
2
Positions
3
2
1
5
4 2 8 6 12 10
Elements
U1
3
12
V
TR
4
10
X
22 1 Pole ammeter switch for 3 current transformers
07 3 Poles changeover switch
1
6 14
13-14
15-16
9-10
3
11-12
5-6
2
7-8
1-2
1
3-4
2
45°
Pos.
W2
4
6
8
7553 Star-Delta switch
Y
5
X
14
X
ST
4 2 8 6
13 15 2
V1
9
RN
06 2 Poles changeover switch
L1
L2
L3
13
4
45°
5
6
1
2
X
8
X
1
0
2
4
45°
1
5-6
7-8
1-2
3-4
7 0 1
6
2
5
3
4
19 Voltmeter switch 1 phase and 3 phase to phase
X
12
X
45°
X
6
X
X
2
0 1 2 3
4
3
Pos.
2 4 6 8 10 12 14
X
0
X
X
67 1 Pole step switch 7 positions + 0
N
L1
L2
L3
X X
10
16
Pos.
45°
X
13-14
15-16 X
9-10
3
11-12
X
5-6
X X
2
7-8
1-2 X
1
3-4
Contact
5
Pos.
Y
0 1
Pos.
7
05 1 Pole changeover switch
0 Y
4
4 14 10 12
4
Elements
16
6
Contact
14
15
0
5
Contact
13
X
X
X
X
Elements
1
5-6
7-8
1-2
3-4
Contact
Contact
Elements
2
13 15 2
V1
X X
X X
X
X
X
X
X X
X
4
8 U2
Elements
45°
90°
13-14
15-16
9-10
3
11-12
5-6
2
7-8
1-2
1
3-4
16
5
V2
Elements
Y
Contact
W1 1
0
1
2 4 6 8
Elements
6 14
1
SN
TN
2
8
0 RN
9
X
3
6
Positions
V
TR
L1
L2
L3
5
5
14
X
X
1 0 2
3
0
13
2
18 Voltmeter switch 3 phase and 3 phase to phase
ST
U1
0
9
2 4 6
0
X
X X
X
X X
5
13
57 1 Pole step switch 3 positions + 0
L1
L2
L3
1
V
13-14
15-16
9-10
3
11-12
5-6
2
7-8
1-2
1
3-4
4
6 4 8
1 3 5 7
7323 Star-Delta switch
W2
5
45°
5-6
7-8
1-2
3-4
Contact
V1
4
45°
ST
Elements
45°
9-10
3
11-12 X
5-6 X
2
7-8
1-2
1
3-4 X
3
Pos.
0 RS
2
Contact
5
1
2
1 3 5
03 3 Poles on-off switch
L1
L2
L3
2
Elements
11
0
0
1
16 3 Phase to phase voltmeter switch
0
1
6
5
X
X
1 0 2
2 4
X
X
X
3
10
RN
SN
TN
X
X
X
9-10 X
11-12
5-6 X
2
7-8
1-2
1
3-4 X
9
Contact
X
RS
ST
TR
16
Elements
Contact
Elements
15
3-4
1-2
1
9 5 1
W1
RS
ST
TR
X
X
14
Elements
13-14
15-16
9-10 X
3
11-12 X
5-6
2
7-8
1-2
1
3-4 X
4
13
Contact
1
45°
4
V1
2
Contact
13 15 2
1V
Elements
6
2V
L1
L2
L3
Elements
8
4 2 8 6 12 10 16 14
10
TR
ST
RS
1W
1
RN
16
5
2
Elements
0
01 1 Pole on-off switch
L1
L2
L3
2W
1
Contact
1
14
Contact
2U
U1
Elements
6
45 4 Poles changeover switch
08 3 Poles reversing switch
SERIES 14
1U
0
3
1
2
90°
13-14
15-16
9-10
11-12
5-6
7-8
1-2
3-4
Contact
7293 3 Poles Dahlander switch
1
45°
14
X
10
X
12
X
X
6
X
X
8
X
0 1 2 3 4 5 6 7
Positions
1
2
4
Series R
Circuit diagrams
30°
60°
Date
Order N.
Company
Contact
45°
90°
6
5
4
3
2
Banks
1
8
7
6
5
4
3
2
Banks
1
X
Contact closed
Contacts
Contacts
Notes
Positions
Contact closed in several positions
Rated current Ie AC-21A (A)
Actuator
Delivery date
Positions
29 - 30
31 - 32
25 - 26
27 - 28
21 - 22
23 - 24
17 - 18
19 - 20
13 - 14
15 - 16
9 - 10
11 - 12
5-6
7-8
1-2
3-4
XX
Quantity
from 20A to 25A
7
Fax
from 32A to 315A
8
31 - 32
29 - 30
27 - 28
25 - 26
23 - 24
21 - 22
19 - 20
17 - 18
15 - 16
13 - 14
11 - 12
9 - 10
7-8
5-6
3-4
1-2
Ph.
31
32
29
30
27
28
25
26
23
24
21
22
19
20
17
18
15
16
13
14
11
12
9
10
7
8
5
6
3
4
1
2
29
30
31
32
25
26
27
28
21
22
23
24
17
18
19
20
13
14
15
16
9
10
11
12
5
6
7
8
1
2
3
4
Spring return
Front mounting
Base mounting
Series R
Ordering example for special switches
0
M
Company Rossi & Bianchi
A
Contact
Ph.
45° X
90°
4
3
2
Banks
1
8
7
6
5
4
3
2
Banks
1
X
Contact closed
X X
X
X
X
0 M A
Contacts
Contacts
XX
Positions
Contact closed in several positions
Rated current Ie AC-21A (A)
Actuator
Notes
02 555555
1 week
Delivery date
29
30
27
28
25
26
23
24
21
22
19
20
17
18
15
16
13
14
11
12
9
10
7
8
5
6
3
4
1
2
29
30
31
32
25
26
27
28
21
22
23
24
17
18
19
20
13
14
15
16
Positions
29 - 30
31 - 32
25 - 26
27 - 28
21 - 22
23 - 24
17 - 18
19 - 20
13 - 14
15 - 16
9 - 10
11 - 12
5-6
7-8
1-2
3-4
10 pieces
Fax
pl
5
02 555555
32
from 20A to 25A
6
Rossi
31
from 32A to 315A
7
31 - 32
29 - 30
27 - 28
25 - 26
23 - 24
21 - 22
19 - 20
17 - 18
15 - 16
13 - 14
11 - 12
9 - 10
7-8
5-6
3-4
1-2
Quantity
Ex
am
8
Order N. 0000/00
Date
e
30°
60°
9
10
11
12
5
6
7
8
1
2
3
4
Spring return
20
54 x 54mm (Standard) - complete of legend plate
X Front mounting
Base mounting
Special version
Changeover Sw. 4x1600A
Disconnector Sw. 2200A
visit our web site:
www.breter.it
www.breter.it
Breter s.r.l.
Via Cardinale Riboldi, 161
I - 20037 Paderno Dugnano - Milano
Italy
Tel. +39 0299061.1
Fax +39 029103516
Cam switches R series - 9/2003

Similar documents

Section K - Sprecher + Schuh

Section K - Sprecher + Schuh All control knobs and shafts are spray proof and dust proof to IP65.

More information

Imperial Registers and Grilles

Imperial Registers and Grilles BASEBOARD RETURN AIR ............................................................................................................................  8-8 – 8-9 PROJECTION — 2" PROJECTION — WHITE ........

More information

Boletín Oficial del Principado de Asturias

Boletín Oficial del Principado de Asturias 11030414M 71770476B 71760883D 10952222J 11066554N 10949633T 11075339B 11026977H 71762333X 71645717G 71772366S 11021180V 11057894T 10949642D 11053228A 10948242N 11062416Z 76958174J 10729547R 7188443...

More information