PCM100
Transcription
PCM100
ITALIANO ENGLISH PCM100 230V automation central unit for sliding gate USER MANUAL For PCB circuits 425ama-2.00 or for PCB circuits 425ama-1.01 with work order label "054218" Made in Italy EMC 89/336 CEE PCM100 - User Manual Important Safeguards ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! Please read this manual carefully before the installation and keep it for future reference. Installation, electrical connections and adjustements must comply with technical and safety standards in force. (UNI 8612). HILTRON Srl cannot be held responsible for failure to observe technical standards in the construction of gates, or for any deformation of gates which may occur during the use. This product has been designed and manufactured only for the use stated in this manual. Any other use not expressly set forth will affect the reliability of the product and/or could be source of hazard. HILTRON Srl cannot be held responsible for any damage caused by improper use or different from the use for wich the autamtion system is destined to. Do not use this device in areas subject to explosion: the presence of flammable gas or fumes is a serious hazard. Before carrying out any operations, turn off the system’s main switch. An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more. Alternatively, use a 6A thermomagnetic breaker with a multi-pole switching. Ensure that there is a differential switch up-line of the electrical system, with a trip threshold of 0.03A. Check that the earthing plant is in perfect condition and connect it to the metallic parts. Also earth the Yellow/Green wire of the operator. The end-user must avoid any attempt to repair or adjust the automation personally. These operations must be carried out only by qualified personnel. For maintenance operations, use only CIA original spare parts produced by HILTRON Srl. Do not carry out any modifikeptcations to automation components. Packaging materials (plastic, cardboard, etc.) are a potential hazard and must be out of reach of children. The installer must supply all informations regarding manual operation of the system in the event of an emergency and provide the end-user with this manual attached to the product. The automation is fitted with an anti-crush safety system that is a torque control device. In any case, HILTRON Srl suggests the installation of others safety devices, in ® accordance with standards in force, system operating logic and weight and dimension of the gate. The safety devices (i.e.: photocells, DICHIARAZIONE DI CONFORMITA’ pneumatic edges, etc...) protect areas SECONDO LE NORME ISO/IEC GUIDA 22 EN 45014 wherethere is a mechanical movement hazard (i.e.: crushing, entrapment and COSTRUTTORE: HiLTRON S.r.l. cutting). Each installation must be fitted with INDIRIZZO: Via Caserta al Bravo, 218 Napoli at least one flashing light (i.e.: item MARCHIO UTILIZZATO: LAMP12FG) or with at signalling plate (i.e.: item TRG CIA) fixed to the gate. CODICE PRODOTTO: PCM100 HILTRON Srl cannot be held responsible DESCRIZIONE DEL PRODOTTO: CENTRALE DI AUTOMAZIONE PER CANCELLO regarding safety and correct operation of the SCORREVOLE automation in the event that parts other than Il prodotto sopra descritto risulta conforme ai requisiti prescritti nelle seguenti norme: CIA o r i g i n a l p a r ts ( p r o d u c e d b y HILTRON Srl). PROGETTAZIONI E PRODUZIONI ELETTRONICHE ! ! NORMA APPLICATA TITOLO EN50081-1 (1992) NORMA GENERICA DI EMISSIONE Classe della norma generica: domestico, commerciale ed industriale leggero. EN50082-1 (1992) NORMA GENERICA DI IMMUNITA’ Classe della norma generica: domestico, commerciale ed industriale leggero. EN60335-1 (1996) NORMA PER LA SICUREZZA DEGLI APPARECCHI ELETTRICI D'USO DOMESTICO E SIMILARE La conformita' e' stata valutata sulla base di prove eseguite su campione e con allestimento che rispecchia la configurazione funzionale prevista per la sua utilizzazione allestita interamente con prodotti CIA di produzione HiLTRON S.r.l. . Pertanto il prodotto soddisfa i requisiti della direttiva EMC 89/336/CEE e BT 73/23/CEE. Napoli, 17 Marzo 1999 L’ AMMINISTRATORE DELEGATO 2 Introduction Index Chapter 1 Introduction 4 1.1 Central Unit description.....................................................................................4 1.2 Central Unit Overview .......................................................................................4 1.3 Technical Features ............................................................................................4 Chapter 2 Installation 5 2.1 Board description ..............................................................................................5 2.2 Example of installation ......................................................................................6 2.2.1 Central unit installation...........................................................................6 2.3 Terminal board description ................................................................................7 2.4 Connections ......................................................................................................8 2.4.1 Power supply, flasher, geared-motor, controls ......................................8 2.4.2 Relay photocells connection ..................................................................9 2.4.3 Photocells with autodiagnosis connection .............................................9 2.4.4 Antenna with VHF receiver - BIRD ......................................................10 2.5 Remote-control code setup .............................................................................10 2.6 Remote-control decoder setup ........................................................................11 2.7 Adjustments ....................................................................................................12 2.8 DP1 Dip-switch operating................................................................................12 Chapter 3 Operating Modes 13 3.1 Check LEDs ....................................................................................................13 3.2 Operating modes.............................................................................................14 3.2.1 SEMIAUTOMATIC ...............................................................................14 3.2.2 AUTOMATIC ........................................................................................14 3.2.3 STEP-BY-STEP with automatic reclosing............................................15 3.2.4 STEP-BY-STEP WITH STOP manual mode .......................................15 Chapter 4 Maintenance 16 4.1 Gate .............................................................................................................16 4.2 Fuses .............................................................................................................16 3 PCM100 - User Manual 1 Introduction 1.1 Central Unit Description PCM100 Central Unit for sliding gates operates a geared-motor 230Vac 700VA max, as MS100 or MS200 producted by CIA, by an electrical clutch, realized with a microprocessor of last generation. PCM100 Central Unit is furnished with a sophisticated circuit of autodiagnosis that controls costantly the operation of the system and connected devices; in case of troubles, the circuit stops all central unit operation. The monitoring of peripheral operating connected to the central unit is displayed by LEDs placed on the circuit. Moreover, PCM100 Central Unit is furnished also with a electrical brake to guard the stop of geared-motor. In place of the brake, the slowing down function is activated 3 seconds before the limit stop to avoid unnecessary impacts during the opening and closing operating. PCM100Central Unit is in accordance with EMC 89/336 directives and 73/23 EEC directives. 1.2 ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! 1.3 ! ! ! ! ! ! ! ! ! 4 Central Unit Overview SLOWING DOWN function withBRAKE trimmer at minimum. BRAKE function adjustable by trimmer with exclusion at minimum. SOFT-START excludible function. Programmable operating modes: Automatic, Semiautomatic, step-by-step with automatic reclosing, step-by-step with STOP. Built-in interface for BIRD receiver. TORQUE adjustment by trimmer. Operation Autodiagnosis. Peripheral monitoring by LEDs. BREAK function adjustable by trimmer with exclusion at minimum. Regulation trimmer: BREAK, PAUSE, CROWD FORCE. Total Opening control input. Partial Opening control input. STOP control input. 2 inputs for photocells as IR-SYSTEM with AUTODIAGNOSIS type. External Box in ABS - IP44. Technical Features Power supply voltage: 230V~ ±10% 50Hz Normal Current Absorption: 6W Service output voltage: 24V~ ±5% max 0,3A Opening/closing time: max 90 sec. Time of Pause: 4 ÷ 60 sec. Operating Modes: Automatic, Semiautomatic, Step-by-step with automating reclosing, Manual step-by-step. Operating Temperatures: -25ºC ÷ 55ºC External box dimensions (WxHxD): 127x138x57mm Board dimensions (WxH): 98x118mm Installation 2 Installation 2.1 Board Description 3 4 5 6 Figure 1 16 17 10 9 8 7 14 13 12 1 23 18 11 2 15 19 20 21 22 1 F1 Voltage Fuse (250Vac 3,15A) 12 LED 6 Photocell 2 Status 2 F2 Periph. Protect. Fuse (250Vac 0,315A) 13 LED 7 Opening Limit Stop Status 14 LED 8 Closing Limit Stop Status 3 F3 Logic Fuse (250Vac 0,315A) 15 LED 4 STOP Status 4 TRIM.A Electr. Clutch Adjust. 16 LED 3 Microprocessor diagnosis 5 TRIM.B Time of pause Adjust. 17 DIP1 Dip-Switch 6 TRIM.C Electr. Clutch Time Adjust. 18 CONN Opening/Closing Limit Stop Connectors 7 P1 19 M1 230Vac Power Supply Terminal 20 M2 Flasher and Motor Terminal 21 M3 BIRD and Tot./Part. Opening Signals Terminal 22 M4 Photocell and 24 Vac Periph.P/Supply Terminal 23 MORS Opening/Closing Limit Stop Terminal Total opening button or self/learning 8 P2 Partial opening button or self/learning 9 LED 1 LED Button P1 10 LED 2 LED Button P2 11 LED 5 Photocell 1 Status 5 PCM100 - User Manual 2.2 Example of installation Figure 2 6 2 5 4 1 8 1 MS100 + PCM100 2 FX30 (TX) FX30 (RX) FX30 (RX) FX30 (TX) LAMP230G BIRD SC1 FC1 FC2 CRP 3 4 5 6 7 8 9 10 11 7 3 9 11 10 Geared-motor MS100 with PCM100 central unit and built-in limit stop detector (FCSS) . TX photocell (external gate) RX photocell (external gate) RX photocell (external gate) TX photocell (external gate) 230Vac electronic flasher VHF receiver with antenna Key selector Interface for opening limit stop Interface for closing limit stop Plastic rack 2.2.1 Central Unit installation PCM100 Central Unit can be installed inside the geared-motor MS100 (fig. 3) by the pin furnished , or it be fixed at the wall by two screw anchors (fig. 4). In both cases, you must fix the top to the base by the screw furnished with the central unit. Figura 3 Figura 4 Limit Stop Furnished Pin PCM100 central unit installed inside the gearde-motor MS100 6 PCM100 central unit fixed at the wall Installation 2.3 Terminal Board Description 2 1 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19 8 20 Limit Stop Terminal Board Opening / Closing 21 M1 M1 M1 M3 M2 M3 M2 1 - L1 2 - Ground 3-N Limit Stop Close Open M4 POWER SUPPLY 230V~ ±10% 50Hz M2 4 - Pole 1 5 - Pole 2 230V~ FLASHER 6 - Closing 7 - Common (blue cable) 8 - Opening GEARED-MOTOR (Figure 6) 230V~ 700W max M3 9 - Pole 1 (term. 1 BIRD) 10 - Pole 2 (term. 2 BIRD) "BIRD” ANTENNA 11 - Common 12 - STOP Pulse (NC - Normally Close) 13 - Pulse A (NA - Normally Open) 14 - Pulse B (NA - Normally Open) OPENING CONTROLS M4 15 - NC - Normally Close 16 - Common 17 - NC - Normally Close PHOTOCELLS CONTACTS (FX30 - FX40 - FX55) SERVICES POWER SUPPLY 24V~ max 300mA 18 - Pole 1 19 - Pole 2 LIMIT STOP (20 / 21) 20 - Limit Stop Terminal Board 21 - Limit Stop Connector Figure 5 Limit Stop LIMIT STOP CONNECTOR (figure 5) Limit Stop Terminal Board Figure 6 Limit Stop Connector If the electronical board is installed outside the motor, it’s possible extend the connector’s original cable or use the terminal board. 230Vac Geared-motor Power Supply Common Closing Opening If the central units is installed inside the MS100 geared-motor, connect the limit stop by the cable as shown in the figure 5. Otherwise,if the central unit is installed on the wall, externally at the motor, cut the cable of the connector and extend it. NOTE: If you must exchange the wires round, you must invert “A” and “B” magnetos, of “FC1” and “FC2” (figure 2). 7 PCM100 - User Manual 2.4 Connections 2.4.1 Power supply, flasher, geared-motor, controls Partial opening Optional Controls buttons (entry phone, etc.) STOP NC Opening 2B Closing 3x1,5mm Common (blue cable) Total opening NO OPEN CLOSE 4S M LAMP230G ( 6 fig.2) 230V~ Flasher SC1 ( 8 ) MS100 / MS200 ( 1 fig.2) 230V~ 700W max N.O. N Terra L1 3x1,5mm Timer * POWER SUPPLY 230V~ ±10% 50Hz * 8 It’s possible to connect a timer, as shown above (par.3.2.1), and to set the opening of the gate in a given time. (i.e.: 7:00 ÷ 8:30 a.m.) When the timer is activated (relay contact from NA Normally Open to NC Normally Close), the opening of the gate will stop up to the timer contact will be NC Normally Close. Installation 2.4.2 Relay photocells (FX40, FX55 etc.) DIP1 ON OFF 2B 2B2 24V~ 24V~ Photocell 2 NC RX ( 3 fig.2) ( 2 TX fig.2) 24V~ 24V~ Photocell 1 NC RX ( 4 fig.2) 2.4.3 TX ( 5 fig.2) Photocells with autodiagnosis (FX30) DIP1 ON OFF 2B 2B + - RX ( 4 fig.2) + - Photocell 1 ( 5 TX fig.2) 2B 2B + - TX ( 2 fig.2) Photocell 2 + - RX ( 3 fig.2) 9 PCM100 - User Manual Antenna with VHF receiver - BIRD 2x1mm 2.4.4 BIRD WARNING: Use a shielded cable with two wires, 2S type, only for the connection of BIRD receiver. Do not use free wire of another devices. We rember you to look out the polarity during the connection. 2.5 Remote- control code setup Enter a random code in the remote control (see TWIN or BLACK user manual) follow the instruction in the next paragraph (2.6) to setup the central unit with the same code. TWIN BLACK I.E.: you enter the code : 0 - 1 - 0 - 1 - 1 - 1 - 0 - 0 - 1 - 0 P1 P2 10 P1 P1 P1 P2 ON P1 P2 P2 P2 OFF Installation 2.6 Remote-control decoder setup Auto-Acquisition of Remote-control Code ! ! ! ! Keep down P1 and P2 buttons (in figure 1: 7 and 8 ) for 5 seconds up to the corrsponding two LEDs start to blink (in figure 1: 9 and 10 ) Press P1 button, only LED1 start to blink. During the blinking, press "A" button of remote-control to acquire the code. The LED1 utters a sequence of blinkings to indicate that the code has been acquired and to exit automatically to the setup mode. NOTE: If no remote- control is activated in 10 seconds, the setup is stopped and no code will be programmed. For the acquisition of the code on the channel "B” of the remote-control, repeat the procedure using P2 buttons and LED2 Programmed code display ! ! ! Keep down P1 and P2 buttons (figure 1: 7 and 8 ) up to the corresponding LEDs (figure 1: 9 and 10 ) lights. Press P1 button to display the 12-bit code of "A" channel by a sequence of blinkings of LED1 and LED2): ! one blink of LED1 for dip switch ON ! one blink of LED2 for dip switch OFF After the sequence of blinkings, you will exit automatically to the programming mode; NOTE: If no buttons is pressed in 5 seconds, the produre is stopped and no code will be displayed. To display the code of “B” channel, repeat the procedure using P2 button and LED2. Time of simultaneous pressure of P1 e P2 buttons: 0 sec. LED Status 2 sec. 5 sec. LED “1” and “2” turn off LED “1” and “2” light LED “1” and “2” blink No action Release P1 and P2 buttons to enter in Code Display Mode. Release P1 and P2 buttons to enter in Auto-acquisition Code Mode Function To simplify the entering of the code in the remote control, use the following table: 1 2 3 4 5 6 7 8 9 10 11 12 P1 = ON LED1 P2 = OFF LED2 11 PCM100 - User Manual 2.7 Adjustments After to have setted all Operating Modes parameters, you must adjust the trimmers on the board: ! Trimmer A Electronical Clutch Adjustment This adjustment works on the thrust force of geared-motor: this force must cause the moving of the gate, and it’s closely dependent on the weight of its structure. During the movement, also the gate acquires a thrust force. Under provisions of the law, the adjustment must be made so that the thrust force of the gate is equal to 15Kg; it means that a force equal to 15Kg, in opposition to the movement of the gate, must stop the gate during its movement. To set this adjustment, we suggest you to use an instrument called linear dynamometer. Trimmer B Time of Pause Adjustment If the central unit is setted on Automatic Operation, you must adjust the time of pause that must elapse between the end of the opening and the start of the closing of the gate. Trimmer C Electronical Brake / Slowing Down This adjustment causes the braking of the gate. Turn the trimmer in clockwise sense to increase the effect of the brake and therefore to reduce the lenght run from the gate. Setting the trimmer on zero, Final Slowing Down function is automatically activated. 2.8 DIP1 - Dip-switch Operating ( 17 in figure 1) ATTENTION: DIP- SWITCH setting have to be effected when the central unit is switched OFF. DIP1 ON SW1 OFF SW2 OFF Automatic Mode SW1 ON SW2 OFF Step-by-step Mode with automatic reclosing SW1 OFF SW2 ON Step-by-step Mode with STOP function SW1 ON SW2 ON Semiautmatic Mode OFF DIP1 ON OFF DIP1 ON SWITCH 1 e 2 OFF DIP1 ON OFF DIP1 ON OFF DIP1 Open cycle not allowed if light barrier interrupted Open cycle allowed if light barrier interrupted ON Installed Photocell OFF 12 FX30 (autodiagnostic) FX40 - FX55 ON OFF SWITCH 3 ON OFF SWITCH 4 Operation Modes 3 Operation Modes 3.1 Check LEDs There are 8 LEDs to make easy the operation check of peripheral devices installed: LED 1 LED 2 LED 3 green green green Pulse A of total opening status Pulse B of partial opening status Central Unit anomalies check Blink Light on or light off LED 4 LED 5 LED 6 LED 7 LED 8 yellow red red red red Proper Operation of PCM100 Irregular Operation of PCM100 STOP control Photocell 1 Status Photocell 2 Status Opening Limit stop Closing Limit stop LEDs LED ON 1 Pulse on input A (total opening) 2 Pulse on input B (partial opening) 4 No action OFF No action STOP control enabled 5 Photocell 1 ON 6 Photocell 2 ON 7 No action Opening Limit Stop ON 8 Closing Limit stop ON LED Blink Light on or Light off 3 Proper Operation Irregular Operation 13 PCM100 - User Manual 3.2 Operating Modes 3.2.1 Semiautomatic (SW1=OFF - SW2=OFF) One pulse allows : opening , pause , automatic closing . During the opening operation, other pulses will be ignored. During the closing operation, possible pulses stop and reverse the movement of gate immediately. A contact closed on PULSE A ( Clock function ) allows to open the gate up to the setted pause and it be open up to the opening of the contact. GATE STATUS PULSE A PULSE B CLOSE Total Opening and reclosing after the time of pause Partial Opening and closing operation after the time of pause STOP DIP1 ON OFF PHOTOCELL 1 PHOTOCELL 2 See SWITCH 3 No effect if the opening is started by the PULSE A OPENING PARTIAL OPEN IN PAUSE TOTAL OPEN IN PAUSE Total Opening if the opening is started by the PULSE B Total Opening No Effect No Effect The reclosing is stopped and at the end of the pause it restores other 5 sec. up to the reset Stops operation and switches to STOP mode The reclosing is stopped and at the end of the pause, it restores other 5 sec. up to the reset A total opening is possible. The reclosing is stopped and at the end of the pause, it restores other 5 sec. up to the reset The reclosing is stopped and at the end of the pause, it restores other 5 sec. up to the reset CLOSING The closing is stopped and the gate opens again immediately Stops operation and the gate opens immediately IN STOP Restarts the operating procedure before the STOP (closing or opening) The pulses A and B will be ignored. The opening or closing operation are locked 3.2.2 Automatic ( SW1=ON - SW2=OFF) One pulse allows :opening, pause, automatic closing. During opening and closing procedures, every pulse stops and reverse the movement of the gate immediately. During the pause, a pulse recloses the gate immediately. 14 GATE STATUS PULSE A PULSE B CLOSE Total Opening and reclosing after the time of pause Partial Opening and reclosing after the time of pause OPENING The gate stops and it recloses immediately. OPEN IN PAUSE The gate recloses immediately CLOSING The gate stops and it opens immediately. IN STOP Restarts the operating procedure before the STOP (closing or opening) STOP DIP1 ON OFF PHOTOCELL 1 PHOTOCELL 2 See SWITCH 3 No effect Stops operation and switches to STOP mode The reclosing is stopped and at the end of the pause, it restores other 5 sec. up to the reset Stops operation and the gate opens immediately The pulses A and B will be ignored. The opening or closing operation are locked Operation Modes 3.2.3 STEP-BY-STEP mode with automatic reclosing (SW1=OFF- SW2=ON) One pulse allows : opening, pause, automatic closing During opening and closing procedures, every pulse stops and reverse the movement of the gate immediately. During the pause, a pulse recloses the gate immediately. DIP1 ON OFF GATE STATUS PULSE A PULSE B CLOSE Total Opening and reclosing after the time of pause Partial Opening and closing operation after the time of pause OPENING The opening is stopped and the next pulse recloses the gate OPEN IN PAUSE Recloses the gate immediately CLOSING It is locked and only a new pulse recloses the gate IN STOP Restarts the operating procedure before the STOP (closing or opening) 3.2.4 STOP PHOTOCELL 1 PHOTOCELL 2 See SWITCH 3 No Effect Stops operation and switches to STOP mode The reclosing is stopped and at the end of the pause, it restores other 5 sec. up to the reset Stops operation and the gate opens immediately The pulses A and B will be ignored. The opening or closing operation are locked STEP-BY-STEP Manual Mode (SW1=ON - SW2=ON) DIP1 ON One pulses opens; the next pulse stops; the next pulse closes ; the next pulse stops; the next pulse opens, etc . GATE STATUS PULSE A PULSE B CLOSE Total Opening Partial Opening OPENING The opening is stopped and the next pulse recloses the gate STOP Reverses the movement of the motor CLOSING The closing is stopped and the next pulse opens the gate IN STOP Restarts the operating procedure before the STOP (closing or opening) STOP OFF PHOTOCELL 1 PHOTOCELL 2 See SWITCH 3 No Effect Stops operation and switches to STOP mode Pulses A and B are ignored and all movement are locked Stops operation and the gate opens immediately The pulses A and B will be ignored. The opening or closing operation are locked 15 PCM100 - User Manual 4 Maintenance 4.1 Gate It`s suggested to carry out periodic checks on the structure of the gate and in particular it`s suggested to verify verificare the perfect condition of gears, ruck and all mechanical elements. 4.2 Fuses F1 3,15A 250V VOLTAGE Fuse This fuse allows the protection from overloads of the central unit transformer, from voltage drops of the flasher and of the geared-motor. F2 0,315A 250V PERIPHERAL Fuse This fuse allows the protection of the 24Vca output for the peripheral power supply. F3 0,315A 250V LOGIC Fuse This fuse allows the protection of power supply system of all electronical elements connected on the central unit. 16 425ADE-2.01