4PRTL ( 1/2˝ valve ) 4QRTL ( 3/4˝ valve ) ASSEMBLY

Transcription

4PRTL ( 1/2˝ valve ) 4QRTL ( 3/4˝ valve ) ASSEMBLY
151208
ASSEMBLY INSTRUCTION
3 11/16"
4P-4QRTL or Q
TEMPERATURE CONTROL VALVE WITH BUILT-IN STOPS AND VOLUME CONTROL VALVE
178
7"
203
8"
3 7/8"
3 5/8"
1 3/8" HOLE
FEATURES:
- Brass construction with choice of 21 finishes
- Lever or square handle for Shut-Off Volume Control Valve
- Single handle Mixer control
- Factory preset at 38ºC (100.4ºF)
- Temperature range from 15ºC (59ºF) to 60ºC (140ºF)
- Safety stop with override function
1 3/4"
1 3/4"
4PRTL ( 1/2˝ valve )
4QRTL ( 3/4˝ valve )
USE PLASTIC MOUNTING GUIDE
AS A TEMPLATE FOR THE
CORRECT SIZE HOLE
REMOVAL OF FIXTURE:
Always turn the water supply off before removing the existing fixture or disassembling a valve. Open all fixture handles to relieve water pressure
and to ensure that the water has been successfully turned off.
CONTACT US:
If you need assistance with installation, replacement parts or have any questions regarding your Rubinet product,
please call a Customer Service representative at: 905-851-6781 toll free 1-800-461-5901 or visit www.rubinet.com
CARE OF FIXTURE:
The use of warm water and a soft cloth is all that is required to clean Rubinet products. The patina of our living finishes (Oil Rubbed Bronze &
Tuscan Brass) will change as a result of normal use. Applying Mineral Oil on occasion will create a softer look, subtle color changes and character.
TEMPERATURE CONTROL VALVE WITH BUILT-IN STOPS WITH
VOLUME CONTROL VALVE
4P-4QRTL or Q
TEMPERATURE CONTROL VALVE WITH BUILT-IN STOPS WITH
VOLUME CONTROL VALVE
5
Turn cartridge spline into OFF position
before installing handles
4PR000 ( 3 / 4 ˝ ) /
4QR000 ( 1 / 2 ˝ )
Rough-In Valve
9YTCSPL3A
Trim Plate
HRT40
Lever Handle
Assembly
9YTCSPL1C
Valve Sleeve
9YTCSKN1A
Tie Down
Screw & Nut
HRT50
Temperature
Control Handle
4P-4QRTL or Q
TEMPERATURE CONTROL VALVE WITH BUILT-IN STOPS WITH
VOLUME CONTROL VALVE
4P-4QRTL or Q
4
TEMPERATURE CONTROL VALVE WITH BUILT-IN STOPS WITH
VOLUME CONTROL VALVE
4P-4QRTL or Q
1
1 1/8˝
PIPE CLAMP
RECOMMENDED
FOR ROUGH-IN
Mark spline 1 1/8”
from the valve flange
Cut spline where marked
FACTORY CALIBRATED POSITION
(at 38°C / 100°F)
Red marks should be aligned
at 12 O’Clock position
* IF PEX PIPING IS TO BE USED, DO NOT USE PEX WITH A DIAMETER
OF LESS THAN 3/4˝ FOR MAXIMUM FLOW FROM THE VALVE
TEMPERATURE CONTROL VALVE WITH BUILT-IN STOPS WITH
VOLUME CONTROL VALVE
4P-4QRTL or Q
2
TEMPERATURE CONTROL VALVE WITH BUILT-IN STOPS WITH
VOLUME CONTROL VALVE
4P-4QRTL or Q
3
* Install handle with the over-ride button
at 12 o’clock position as shown
Mark threaded sleeve
Cut threaded sleeve where marked