A B1 B2 B3 C C C C

Transcription

A B1 B2 B3 C C C C
INS 4DRBR000
3/4" THERMOSTATIC MIXER
4DRBR000
Toll Free: 1 800 461 5901
Tel: 905 851 6781 / Fax: 905 851 8031
Email: [email protected]
1
BEFORE YOU BEGIN
C
FLOW
B1
Reduce to 1/2"
for best
performance
READ ALL DIRECTIONS PRIOR TO INSTALLATION. ANY ALTERATIONS
MADE TO THE VALVE OR CARTRIDGE AND FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY CAUSE DAMAGE OR IMPROPER INSTALLATION
WHICH WILL NULLIFY THE WARRANTY AS WELL AS INCREASE THE RISK
OF SCALDING.
• Observe and adhere to all local building and plumbing codes.
C
B2
• Shut off the main water supply.
• The 4DRBR000 thermostatic mixer valve requires a 4ERBR000 volume
control/shut-off valve for each bath and/or shower outlet. Each volume
control/shut-off valve should be installed a minimum of 7" from the
4DRBR000 mixer valve in any direction.
• A 3/4" NPT plug must be installed in any unused outlets.
• The mixer valve contains plastic and rubber components. DO NOT sweat or
braze directly to the valve. DO NOT apply excessive heat to the valve when
making solder connections. The inlet and outlet threaded joint connections
should be made using plumbers tape or approved liquid sealant. DO NOT
use an oil-based or non-setting compound.
A
• A mounting jig is attached to the mixer valve. Do not remove it until instructed
to do so.Trace the outline of the jig for the cut-out in the wall material.
COLD
HOT
•
Use the jig to determine the depth of the valve in the wall. The finished wall
must be within the MIN-MAX depth indicated on the mounting jig. Finished
Wall refers to the ultimate finished surface, Tile, Marble etc.
• It is recommended that the pipes be flushed clean prior to installation, in
order to avoid problems with debris later.
B3
C
TYPICAL INSTALLATION FIG. 1
A
Thermostatic Mixing Valve
B1 Volume Control/Shut-Off Valve for Overhead Shower
Reduce to 1/2"
for best
performance
B2 Volume Control/Shut-Off Valve for Slide Bar/Hand Shower
B3 Volume Control/Shut-Off Valve for Tub Spout/Body Jets
C
1/2"NPT x 1/2"NPSM x 3" Nipple
C
ROUGH-IN NOTES
Use thread sealant and connect the hot and cold water supply to the inlet ports.
Make sure that the corresponding water supply lines are connected to the
correct inlet port, HOT on the left and COLD on the right (Fig. 1). Connect
outlet ports in the same way and plug any unused ports.
The 4DRBR000 mixing valve does not contain an integral volume
control/shut-off valve. You must install a seperate valve (4ERBR000)
downstream from the mixing valve for each bath and/or shower outlet.
Each volume control/shut-off valve should be installed a minimum of 7" from the
4DRBR000 mixer valve in any direction.
IMPORTANT! Secure all piping to the framing.
Use the mounting jigs to determine the depth of each valve in the wall. The
finished surface of the wall must be within the MIN-MAX (Fig. 3 & 5) depth
shown on the mounting jig.
When the installation is complete, run water through the entire system. Remove
the mounting jig to inspect the mixer valve and cartridge alignment (Fig. 6 & 7).
INS 4DRBR000
2
3
Finished Wall
Finished Wall
Mounting Jig
MAX wall limit
MIN wall limit
4
5
Finished Wall
Finished Wall
FLOW
Mounting Jig
FLOW
MAX wall limit
MIN wall limit
6
7
Protective Tube
Mounting Jig
Specifications
9XVLVTCBA
Features
- Brass construction
- Wall mount
- Single handle control
- High temperature limit stop
- Temperature range from 15ºC (59ºF) to 60ºC (140ºF)
- Factory preset at 38ºC (100.4ºF)
- 3/4"NPT connections
- Filter screens
- Less Volume Control
3/4" Thermostatic Mixer
Model: 9XVLVTCBA
123
4 13/16"
104
4 1/8"
79
3 1/8"
42
1 5/8"
79
3 1/8"
37
1 7/16"
18
3/4"
146
5 3/4"
40
1 9/16" Min Finished Wall
59
2 5/16" Max Finished Wall
STOPS
3/4"NPT ALL PORTS
Critical Dimensions
TEL: 905-851-6781
FAX: 905-851-8031
TOLL FREE: 800-461-5901
THE
Rubinet FAUCET COMPANY
03/02/2010
www.rubinet.com
INS 4MRBR000
1/2" THERMOSTATIC MIXER
4MRBR000
Toll Free: 1 800 461 5901
Tel: 905 851 6781 / Fax: 905 851 8031
Email: [email protected]
1
BEFORE YOU BEGIN
C
FLOW
READ ALL DIRECTIONS PRIOR TO INSTALLATION. ANY ALTERATIONS
MADE TO THE VALVE OR CARTRIDGE AND FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY CAUSE DAMAGE OR IMPROPER INSTALLATION
WHICH WILL NULLIFY THE WARRANTY AS WELL AS INCREASE THE RISK
OF SCALDING.
B1
• Observe and adhere to all local building and plumbing codes.
• Shut off the main water supply.
• The 4MRBR000 thermostatic mixer valve requires a 4KRBR000 volume
control/shut-off valve for each bath and/or shower outlet. Each volume
control/shut-off valve should be installed a minimum of 7" from the
4MRBR000 mixer valve in any direction.
• A 1/2" NPT plug must be installed in any unused outlets.
• The mixer valve contains plastic and rubber components. DO NOT sweat or
braze directly to the valve. DO NOT apply excessive heat to the valve when
making solder connections. The inlet and outlet threaded joint connections
should be made using plumbers tape or approved liquid sealant. DO NOT
use an oil-based or non-setting compound.
A
• A mounting jig is attached to the mixer valve. Do not remove it until instructed
to do so.Trace the outline of the jig for the cut-out in the wall material.
COLD
HOT
•
Use the jig to determine the depth of the valve in the wall. The finished wall
must be within the MIN-MAX depth indicated on the mounting jig. Finished
Wall refers to the ultimate finished surface, Tile, Marble etc.
• It is recommended that the pipes be flushed clean prior to installation, in
order to avoid problems with debris later.
B2
C
TYPICAL INSTALLATION FIG. 1
A
Thermostatic Mixing Valve
B1 Volume Control/Shut-Off Valve for Overhead Shower
B2 Volume Control/Shut-Off Valve for Slide Bar/Hand Shower
C
1/2"NPT x 1/2"NPSM x 3" Nipple
C
ROUGH-IN NOTES
Use thread sealant and connect the hot and cold water supply to the inlet ports.
Make sure that the corresponding water supply lines are connected to the
correct inlet port, HOT on the left and COLD on the right (Fig. 1). Connect
outlet ports in the same way and plug any unused ports.
The 4MRBR000 mixing valve does not contain an integral volume
control/shut-off valve. You must install a seperate valve (4KRBR000)
downstream from the mixing valve for each bath and/or shower outlet.
Each volume control/shut-off valve should be installed a minimum of 7" from the
4MRBR000 mixer valve in any direction.
IMPORTANT! Secure all piping to the framing.
Use the mounting jigs to determine the depth of each valve in the wall. The
finished surface of the wall must be within the MIN-MAX (Fig. 3 & 5) depth
shown on the mounting jig.
When the installation is complete, run water through the entire system. Remove
the mounting jig to inspect the mixer valve and cartridge alignment (Fig. 6 & 7).
INS 4MRBR000
2
3
Finished Wall
Finished Wall
Mounting Jig
MAX wall limit
MIN wall limit
4
5
Finished Wall
Finished Wall
FLOW
Mounting Jig
FLOW
MAX wall limit
MIN wall limit
6
7
Protective Tube
Mounting Jig
Specifications
9XVLVTCCA
Features
- Brass construction
- Wall mount
- Single handle control
- High temperature limit stop
- Temperature range from 15ºC (59ºF) to 60ºC (140ºF)
- Factory preset at 38ºC (100.4ºF)
- 1/2"NPT connections
- Filter screens
- Less Volume Control
1/2" Thermostatic Mixer
Model: 9XVLVTCCA
124
4 7/8"
105
4 1/8"
79
3 1/8"
42
1 5/8"
79
3 1/8"
37
1 7/16"
18
3/4"
146
5 3/4"
40
1 9/16" Min Finished Wall
59
2 5/16" Max Finished Wall
STOPS
1/2"NPT ALL PORTS
Critical Dimensions
TEL: 905-851-6781
FAX: 905-851-8031
TOLL FREE: 800-461-5901
THE
Rubinet FAUCET COMPANY
03/02/2010
www.rubinet.com