avl reagents

Transcription

avl reagents
CONSUMABLES
FOR AVL INSTRUMENTS - PRODUCT OVERVIEW
INTENDED USE FOR SALES AND SERVICE!
PD0053
REV. 3.0
CONTENTS
Page
REAGENTS .............................................................. 1
QUALITY CONTROL MATERIAL .............................. 6
ELECTRODES / SENSORS / OPTODES................. 10
SAMPLE COLLECTION DEVICES .......................... 17
ACCESSORIES ...................................................... 21
Note
To guarantee long-term reliability and accuracy of AVL instruments, we
recommend using AVL reagents, AVL electrodes and AVL accessories
exclusively. They have been designed specifically for use in AVL instruments and
take into consideration all requirements of the AVL instruments to ensure correct
and reproducible measurement results.
The preservatives, wetting and cleaning agents contained in AVL reagents were
optimally balanced to meet the requirements of AVL instruments and electrodes.
Electrode cleaning and conditioning in the instruments is achieved optimally by
using the AVL reagents designed and optimized specifically for this purpose.
The heparin types and concentrations used in AVL capillary tubes to prevent
blood clotting were selected specifically to meet the requirements of blood gas,
electrolyte and metabolite analysis to eliminate any deviation of measured values.
The volume of the AVL capillary tubes has been adjusted to meet the
requirements of the respective instruments and thus allows collection of the
required sample volume. The outer diameter of the AVL capillary tubes was
designed to fit the sample fill port of the AVL instruments and the capillary tips
have been polished to prevent injury or damage to the fill port.
The combined use of AVL reagents, AVL electrodes and AVL accessories was
tested intensively and thus ensures optimal operation of the AVL instruments.
QUALITY CERTIFICATE - AVL REAGENTS
Our Quality Assurance System complies with the requirements of the ÖNORM
EN ISO 9001.
The water used for the production of AVL Reagents undergoes multilevel
processing and is therefore of the highest quality. It has an initial conductivity of
< 0.3 µS/cm and is sterile and pyrogen-free.
AVL Reagents are produced in accordance with manufacturers‘ specifications.
The raw materials and testing devices used are traceable to N.I.S.T. StandardMaterials.
The consistent quality of the AVL reagents is ensured by strict adherence to
testing protocols during production and testing of samples at periodic intervals.
AVL Reagents are being tested with regard to hazardous properties in
accordance with the Austrian Chemical Substances Law and the pertinent EC –
Guidelines.
ENVIRONMENTAL PROTECTION
THE GREEN DOT
-
For years AVL has played an active role in the protection of the environment by
using recyclable and biologically safe packing materials.
AVL also participates in the Dual System (THE GREEN DOT) to demonstrate a
positive attitude towards a substantial reduction and avoidance of packaging
waste to protect the environment.
USE OF AVL REAGENTS ENSURES CONSISTENT QUALITY
To ensure reliability and precision of AVL instruments for the long term, we
recommend the exclusive use of AVL Reagents. They have been designed
specifically for use in AVL instruments and meet all requirements of the AVL
instruments to ensure correct and reproducible measurement results.
The preservatives, wetting- and cleaning agents contained in AVL Reagents are
optimally balanced and meet the requirements of AVL instruments and
electrodes. Electrode conditioning and maintenance in the instrument is
optimized by use of AVL Reagents.
The interaction of AVL Reagents and AVL Electrodes has been tested
intensively and thus ensures optimal functioning of AVL instruments.
REAGENTS
All reagents listed below are for diagnostic in-vitro use exclusively.
À AVL Blood Gas Instruments
v AVL 99X-/94X-Instruments
(AVL 995-Hb, 995, 993, 990
AVL 947, 945, 940)
Contents
Buffer Type 1 (pH 7.383)
Buffer Type 2 (pH 6.841)
pH Reference Solution (0.6 mol/L KCl)
Cleaning Solution
Rinse
Rinse Additive
Deproteinizer
tHb Calibrator
P CO 2 /TCO 2 Filling Solution
P O 2 Filling Solution
Disposable Waste Bottle with cap
3x90
3x90
3x90
125
6x430
100x1
125
5x2
125
125
20
mL
mL
mL
mL
mL
mL
mL
mL
mL
mL
pcs.
Order-No.
BP0136
BP0137
BP0134
BP1303
BP1890
BP0337
BP0521
BP1360
BP1286
BP1414
BP1502
1
REAGENTS
À AVL Blood Gas Instruments
v AVL COMPACT 1, AVL COMPACT 2,
AVL COMPACT 3
Buffer Type 1 (pH 7.383) (AVL COMPACT 1, 2, 3)
Buffer Type 2 (pH 6.841) (AVL COMPACT 2, 3)
pH Reference Solution (0.6 mol/L KCl)
Cleaning Solution
Cleaning Solution (AVL COMPACT 2, 3)
Rinse
Rinse Additive
Deproteinizer
BG Calibrator including adapter (AVL COMPACT 1)
P CO 2 /TCO 2 Filling Solution
P O 2 Filling Solution
Disposable Waste Bottle with cap
Contents
Order No.
3x90 mL
3x90 mL
3x90 mL
125 mL
3x90 mL
6x430 mL
100x1 mL
125 mL
30x2 mL
125 mL
125 mL
20 pcs.
BP0136
BP0137
BP0134
BP1303
BP1889
BP1890
BP0337
BP0521
BP1579
BP1286
BP1414
BP1502
Contents
Order No.
30x4 mL
5 x 2 mL
125 mL
BP1564
BP1360
BP0521
À AVL CO-Oximetry Instruments
v AVL 912
CO-Ox Zero Rinse Additive
tHb Calibrator
Deproteinizer
2
REAGENTS
À AVL Electrolyte Instruments
v AVL 98X (980, 982 –987),
AVL 988-X (988-3/4)
Standard A (for AVL 980 Cl, 982, 983, 985, AVL 988-3 Cl/Li)
Standard A (for AVL 984, 987, 988-3 Ca, 988-4 K)
Standard A ( for AVL 980 Ca)
Standard A ( for AVL 986)
Standard A ( for AVL 988-4 Mg)
Standard B (for AVL 980 Ca, 980 Cl, 982, 983)
Standard B (for AVL 985, 988-3 Cl/Li)
Standard B ( for AVL 984, 987, 988-3 Ca, 988-4 K)
Standard B ( for AVL 986)
Standard B ( for AVL 988-4 Mg )
Standard C ( for AVL 985, 988-3 Li)
Standard C (for AVL 988-4 Mg)
Standard D ( for AVL 988-4 Mg)
Reference Solution ( 1.2 mol/L KCl)
Contents
3x430
3x430
3x430
3x90
3x430
3x90
3x90
3x90
3x90
3x90
3x90
3x90
3x50
3x90
Order-No.
mL
mL
mL
mL
mL
mL
mL
mL
mL
mL
mL
mL
mL
mL
BP0936
BP1232
BP0332
BP1203
BP1598
BP0442
BP0937
BP1218
BP1201
BP1599
BP0938
BP1600
BP1601
BP0095
3x90 mL
125 mL
125 mL
3x430 mL
125 mL
125 mL
25 mL
25 mL
BP1774
BP1607
BP1225
BP1200
BP0521
BP0380
BP1052
BP1053
125 mL
500 mL
500 mL
BP1286
BP0344
BP1405
(for AVL 98X and AVL 988-X except 988-4 Mg)
Reference Solution 2 ( for AVL 988-4 Mg)
Cleaning Solution ( for electrolyte systems)
Cleaning Solution ( for AVL 986)
Releasing Agent (for AVL 986)
Deproteinizer
Sodium Electrode Conditioner
Electrode Filling Solution for Na +
Electrode Filling Solution for K + , Cl - , Ca ++ , Li + and
pH
P CO 2 /TCO 2 Filling Solution
Urine Diluent
Urine Diluent (for AVL 986)
PRODUCT OVERVIEW
3
REAGENTS
À AVL Electrolyte Instruments
v AVL 91XX
Snap Pack (9120, 9130)
Snap Pack (9110, 9140)
Snap Pack (9180, 9181)
Cleaning Solution (for electrolyte systems)
Sodium Electrode Conditioner
Deproteinizer
Electrode Filling Solution for Na +
Electrode Filling Solution for K + , Cl - , Ca ++ , Li + and pH
Urine Diluent
4
Contents
1
1
1
125
125
125
25
25
500
pc.
pc.
pc.
mL
mL
mL
mL
mL
mL
Order No.
BP5016
BP5032
BP5186
BP1607
BP0380
BP0521
BP1052
BP1053
BP0344
REAGENTS
À AVL OMNI Instruments
Description
AVL OMNI Solution
AVL OMNI Solution
AVL OMNI Solution
AVL OMNI Solution
AVL OMNI Solution
AVL OMNI Solution
AVL OMNI Solution
AVL OMNI Solution
AVL OMNI Solution
AVL OMNI Solution
AVL OMNI Solution
AVL OMNI Solution
AVL OMNI Solution
AVL OMNI Solution
Deproteinizer
tHb Calibrator
NOTE:
A
B
C
D (GLU/LAC)
D (GLU/LAC/UREA)
R
1 (GLU/LAC)
1 (GLU/LAC/UREA)
2
3 (GLU/LAC)
3 (GLU/LAC/UREA)
4
5 (GLU/LAC)
5 (GLU/LAC/UREA)
Contents
Order No.
6x820 mL
6x820 mL
6x480 mL
6x480 ml
6x480 ml
12x100 ml
4x40 ml
4x38 ml
4x40 ml
4x40 ml
4x38 ml
4x40 ml
6x100 ml
6x98 ml
125 mL
5x2 mL
BP1893
BP1892
BP1891
BP2279
BP2191
BP1894
BP2248
BP2192
BP1898
BP2249
BP2193
BP2068
BP2278
BP2194
BP0521
BP1360
- AVL OMNI Solutions B and C must always be replaced together.
- To reduce waste products, empty Solution A and B bottles may be
used as waste containers.
v Waste Container
Waste Container
Reusable Waste Container
6x820 mL
1x820 mL
BP1895
BP2257
External Waste Container System:
External Waste Container
Waste Collector for AVL OMNI
Accessories for External Waste Container
2x4 L
1x820 mL
1 pc.
BP2419
BP2417
BP2407
2x180 mL
2x180 mL
BP2424
BP2425
v AVL MSS Conditioning System
GLU/LAC Conditioning Solution
GLU/LAC/UREA Conditioning Solution
PRODUCT OVERVIEW
5
QUALITY CONTROL MATERIAL
À ISE-trol
À COMBI-trol
À COMBI-trol PLUS
À AUTO-trol COMBI
À AUTO-trol PLUS
À CONFITEST III
À CONFITEST CO-Ox
À OPTI-trol
À OPTI-check
6
QUALITY CONTROL MATERIAL
À ISE-trol
Description
uncolored
electrolyte
solution
Parameters
Levels
electrolytes:
Level 1:
Na + , K + , Cl - , Ca ++ , Level 2: normal values
+
++
Li , Mg , TCO 2 ,
Level 3:
pH
+
+
+
-
++
Order No.
Contents
HC0033
3x12x1.0 mL
ampoules
++
Level 1: low values for Na , K , Li , Cl ; high values for Ca , Mg
++
++
+
+
+
Level 3: low values for Ca , Mg ; high values for Na , K , Li , Cl , normal TCO 2
À COMBI-trol
Description
colored
aqueous
solution
Parameters
Levels
pH/blood gases:
Level 1:
pH, P O 2 , P CO 2,
Level 2: normal values
electrolytes:
Level 3:
+
+
++
Na , K , Cl , Ca ,
+
Li , TCO 2
tHb, Hb-derivatives :
O 2 Hb, COHb, HHb
MetHb, SulfHb
+
+
-
+
Order No.
Contents
HC0071
HC0072
HC0073
30x1.7 mL
ampoules
++
Level 1: respiratory acidosis, low values P O 2 , Na , K , Cl , Li , high values for Ca and tHb
+
+
+
++
Level 3: respiratory alkalosis, high values P O 2 , Na , K , Cl , Li , low values for Ca and tHb
À COMBI-trol PLUS
Description
colored
aqueous
solution
Parameters
Levels
pH/blood gases:
Level 1:
pH, P O 2 , P CO 2,
Level 2: normal values
electrolytes :
Level 3:
Na + , K + , Cl - , Ca ++ ,
+
Li , TCO 2
tHb, Hb-derivatives :
O 2 Hb, COHb, HHb
MetHb, SulfHb
metabolites :
Glu, Lac, Urea
+
+
-
Order No.
Contents
HC9038
HC9039
HC9040
30x1.7 mL
ampoules
++
+
Level 1: respiratory acidosis, low values for P O 2 , Na , K , Cl , Glu and tHb, high values for Ca , Li , Lac
and Urea
+
+
++
+
Level 3: respiratory alkalosis, high values for P O 2 , Na , K , Cl , Glu and tHb, low values for Ca , Li , Lac
and Urea
PRODUCT OVERVIEW
7
QUALITY CONTROL MATERIAL
À AUTO-trol COMBI
Description
colored
aqueous
solution
Parameters
Levels
pH/blood gases :
Level 1:
pH, P O 2 , P CO 2,
Level 2: normal values
electrolytes :
Level 3:
+
+
++
Na , K , Cl , Ca
tHb, Hb-derivatives:
O 2 Hb, COHb, HHb
MetHb, SulfHb
+
+
-
Order No.
Contents
HC9032
HC9033
HC9034
2 mats
(20x1.6 mL
ampoules)
++
Level 1: respiratory acidosis, low values P O 2 , Na , K , Cl , high values for Ca and tHb
+
+
++
Level 3: respiratory alkalosis, high values for P O 2 , Na , K , Cl , low values for Ca and tHb
À AUTO-trol PLUS
Description
colored
aqueous
solution
Parameters
Levels
pH/blood gases:
Level 1:
pH, P O 2 , P CO 2,
Level 2: normal values
electrolytes :
Level 3:
+
+
++
Na , K , Cl , Ca
tHb, Hb-derivatives :
O 2 Hb, COHb, HHb
MetHb, SulfHb
metabolites :
Glu, Lac, Urea
+
+
-
Order No.
Contents
HC9041
HC9042
HC9043
2 mats
(20x1.6 mL
ampoules)
++
Level 1: respiratory acidosis, low values for P O 2 , Na , K , Cl , Glu and tHb, high values for Ca , Lac and
Urea
+
+
++
Level 3: respiratory alkalosis, high values for P O 2 , Na , K , Cl , Glu and tHb, low values for Ca , Lac and
Urea
8
QUALITY CONTROL MATERIAL
À CONFITEST III
Description
uncolored,
aqueous
solution
Parameters
pH/blood gases :
pH, P O 2 , P CO 2
Levels
Level
Level
Level
Level
Level
1: acidosis
2: normal values
3: alkalosis
4: high P O 2
1-3
Order No.
Contents
HC9027
HC9028
HC9029
HC9030
HC0049
30x1.7mL
ampoules
3x12x1.7mL
ampoules
À CONFITEST CO-Ox
Description
bovine blood
based solution
Parameters
Levels
Order No.
Contents
US0811
US0812
US0813
30x1.2mL
ampoules
Levels
Order No.
Contents
Level 1: acidosis
Level 2: normal values
Level 3: alkalosis
HC7001
HC7002
HC7003
30x1.7 mL
ampoules
Order No.
Contents
HC7008
3x10x1.7 mL
ampoules
tHb, Hb-derivatives : Level 1: low tHb
O 2 Hb, COHb, HHb
Level 2: normal tHb
MetHb, SulfHb
Level 3: high tHb
À OPTI-trol (for AVL OPTI 1)
Description
uncolored,
aqueous
solution
Parameters
pH/blood gases:
pH, P O 2 , P CO 2
À OPTI-check (for AVL OPTI CCA)
Description
aqueous
solution
Parameters
pH/blood gases:
pH, P O 2 , P CO 2
electrolytes:
Na + , K +
tHb, SO 2
PRODUCT OVERVIEW
Levels
Level 1 - Level 3
9
ELECTRODES / SENSORS / OPTODES
À AVL Blood Gas Electrodes
v zero-maintenance
v remembranable
À AVL Electrolyte Electrodes
v screw type
v sealed type
À AVL OMNI Micro-Electrodes
v Blood gas
v Electrolyte
À AVL OMNI Metabolite Sensors
v Glu
v Glu/Lac
v Glu/Lac/Urea
À AVL Optodes
v AVL OPTI cassettes
10
ELECTRODES / SENSORS / OPTODES
À AVL Blood Gas Electrodes
For instruments of the 94X, 99X and COMPACT series, you may choose between two
different electrode types:
•
•
zero-maintenance electrodes
remembranable electrodes
v Zero-maintenance Electrodes
Features and Benefits
Simple
•
Truly maintenance free pH, P CO 2 and P O 2 electrodes.
After placing the electrodes into the measuring chamber
absolutely no user manipulation required.
Time saving
•
•
•
No remembraning procedure.
No scheduled debubbeling procedures.
No top up of electrode solution required. The pH-reference
electrode is selffilling.
Flexible
•
Fully operational in all AVL blood gas analyzers (AVL 94X, AVL
99X, AVL COMPACT).
A combination of zero-maintenance electrodes and
remembranable electrodes in one analyzer is possible. This
makes the step-by-step upgrade without financial loss possible.
•
•
Reliable
NOTE:
Expected lifetime of about 1.5 years for all zero-maintenance
electrodes.
AVL zero-maintenance electrodes require no maintenance operation
and best performance of the AVL zero-maintenance electrodes will
be achieved following the advices below.
Once in place, the electrodes should not be removed until it is to be
replaced, even not for cleaning of the measuring chamber.
Avoid contact with hard surfaces and take care not to strike the rear
of the measuring chamber
Repeated handling increases the risk of damaging the electrode
membrane.
PRODUCT OVERVIEW
11
ELECTRODES / SENSORS / OPTODES
À AVL Blood Gas Electrodes
v Remembranable Electrodes
Features and Benefits
Long term cost saving
Flexible
Reliable
NOTE:
.
12
•
Conscientious electrode maintenance prolongs the
lifetime of electrodes considerably.
• Fully operational in all AVL blood gas analyzers
(AVL 94X, AVL 99X, AVL COMPACT).
• A combination of zero-maintenance electrodes and
remembranable electrodes in one analyzer is
possible. This makes step-by-step upgrade
possible, without financial loss.
•
Expected lifetime of remembranable electrodes is 2
to 3 years.
When treated accordingly, one of the biggest advantages of the AVL
remembranable electrodes is their extended lifetime. Regulare and
careful maintenance of the electrodes assures the quality of
measurement results and extends the lifetime considerably. Please
follow the instructions given in the section "Maintenance" of the
Operator’s Manuals of AVL blood gas analyzers.
ELECTRODES / SENSORS / OPTODES
À AVL Blood Gas Electrodes
Description
pH Electrode (zero-maintenance)
P CO 2 Electrode (zero-maintenance)
P O 2 Electrode (zero-maintenance)
pH Electrode (remembranable)
P CO 2 Electrode (remembranable)
P O 2 Electrode (remembranable)
pH Reference Electrode
pH Reference Electrode (for AVL 94x and AVL 93x)
pH Reference Housing
pH Electrode Housing
P CO 2 Membrane Housing
P O 2 Membrane Housing
Electrode Cleaning Pad
Coroplast
Cleaning Paste
Cable for Zero-Maintenance Electrodes
Dummy Electrodes
Parafilm
PRODUCT OVERVIEW
Contents
Order No.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
10 pcs.
10 pcs.
10 pcs.
10 pcs.
1 pc.
1 pc.
1 tube
1 pc.
4 pcs.
30 x 10 cm
BP1390
BP1389
BP1388
BP0357
BP0356
BP0355
BP1044
BP0354
BP1090
YB0735
YB0733
YB0732
YB0731
SK0188
HC0012
BV1320
YB0730
BP0389
13
ELECTRODES / SENSORS / OPTODES
À AVL Electrolyte Electrodes
You may choose between two different types of electrodes:
•
AVL zero-maintenance electrolyte electrodes (sealed type)
•
AVL refillable electrolyte electrodes (screw type)
v AVL Electrolyte Instruments
(AVL 98X, 988-X, 91XX)
Contents
Order No.
Na + Electrode (sealed-type)
K + Electrode (sealed-type)
Cl - Electrode (sealed-type)
++
Ca Electrode (sealed-type)
Li + Electrode (sealed-type)
Mg ++ Electrode (sealed-type)
Na + Electrode (screw-type) *
K + Electrode (screw-type) *
Cl - Electrode (screw-type) *
Ca ++ Electrode (screw-type) *
pH Electrode Housing
Ag/AgCl Electrode (for pH electrode)
Reference Electrode (for AVL 98X and 988-X)
Reference Electrode Housing (for AVL 98X and 988-X)
Electrode Cable (for AVL 98X and 988-X)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
pc.
pc.
pc.
pc.
pc.
pc.
pc.
pc.
pc.
pc.
pc.
pc.
pc.
pc.
pc.
BP0413
BP0359
BP0570
BP0360
BP0962
BP1597
BP0829
BP0824
BP0823
BP0932
BP1237
BP1033
BP0713
BP0844
BP0349
Reference Electrode (for AVL 91XX instruments)
Reference Electrode Housing
(for AVL 91XX instruments)
1 pc.
1 pc.
BP5026
BP5019
Dummy Electrode
1 pc.
BP0148
* Not available in all countries
14
ELECTRODES / SENSORS / OPTODES
À AVL OMNI Micro-Electrodes
The AVL OMNI Micro-Electrodes represent a new generation of sensors optimized
with regard to minimal sample volume and zero maintenance. All electrodes are
flow-through electrodes with visible sample channel.
v AVL OMNI
Cl - Electrode
Na + Electrode
K + Electrode
Ca ++ Electrode
P CO 2 Electrode
P O 2 Electrode
pH Electrode
Ref Electrode
Junction Electrode
Dummy Electrode
AVL OMNI ISE Electrode Kit
+
+
++
-
(Na , K , Ca , Cl , Ref., Jun)
AVL OMNI BG Electrode Kit
Contents
1
1
1
1
1
1
1
1
1
1
pc.
pc.
pc.
pc.
pc.
pc.
pc.
pc.
pc.
pc.
BP1729
BP1730
BP1731
BP1732
BP1733
BP1734
BP1735
BP2081
BP2082
BP1959
1 Box
BP2006
(1 pc. / type)
1 Box
(pH, P O 2 , P CO 2 , Ref., Jun.)
(1 pc. / type)
Cl-Cleaning Kit
1 package
PRODUCT OVERVIEW
Order No.
BP2007
BP2276
15
ELECTRODES / SENSORS / OPTODES
À AVL OMNI Metabolite Sensors
The new AVL thick-film technology allows for an entirely new way of producing
glucose/lactate/urea sensors in one cassette. AVL metabolite cassettes are
absolutely maintenance-free and easy to replace.
v AVL OMNI
Contents
Order No.
Glucose Cassette
Glucose/Lactate Cassette
Glucose/Lactate/Urea Cassette
1 pc.
1 pc.
1 pc.
BP2094
BP2096
BP2093
RCon (Reference Contact)
MSS Dummy Cassette
1 pc.
1 pc.
BP2258
BP2284
À AVL Optodes
v AVL OPTI
Contents
AVL OPTI 1 Cassette
Order No.
25 pcs.
BP7508
25 pcs.
BP7562
25 pcs.
BP7558
1 pc.
BP7536
1 pc.
BP7554
1 pc.
BP7543
(pH, P O 2 , P CO 2 )
AVL OPTI CCA Sensor Cassette B
(pH, P O 2 , P CO 2 , tHb, SO 2 )
AVL OPTI CCA Sensor Cassette E
+
+
(pH, P O 2 , P CO 2 , tHb, SO 2 , Na , K )
Standard Reference Cassette low
(for AVL OPTI 1 and AVL OPTI CCA)
Standard Reference Cassette normal
(for AVL OPTI 1 and AVL OPTI CCA)
Standard Reference Cassette high
(for AVL OPTI 1 and AVL OPTI CCA)
16
SAMPLE COLLECTION DEVICES
À AVL Capillary Tubes
À AVL Microsampler
À
AVL Syringe
Note:
Lithium- or sodium heparin or a balanced heparin mixture is the only
permissible anticoagulants for blood gas and electrolyte analysis. Other
anticoagulants such as EDTA, citrate, oxalate and fluoride have a
significant impact on some of the measurement parameters and should
not be used.
PRODUCT OVERVIEW
17
SAMPLE COLLECTION DEVICES
À AVL Capillary Tubes
Due to a special heparin coating, AVL capillaries
are especially suited for pH / blood gas-,
electrolyte and metabolite analysis.
Description
Contents
Order No.
Glass Capillary Tubes, min. 115 µL 1)
6 I.E. Na heparin,
9 I.E. Li heparin/100µL
4 x 250
MG0002
Glass Capillary Tubes, min. 115 µL
9 I.E. Na heparin,
6 I.E. ammonium heparin/100µL
for electrolyte analysis
4 x 250
MG0023
Glass Capillary Tubes, min. 115 µL
24 I.E. Na heparin/100µL
for pH/ blood gas analysis
special heparinized for fetal
sampling
4 x 250
CH2045
Glass Capillary Tubes, min. 180 µL 2)
6 I.E. Na heparin,
9 I.E. Li heparin/100µL
4 x 250
MC0020
Glass Capillary Tubes, min. 200 µL 3)
6 I.E. Na heparin,
9 I.E. Li heparin/100µL
4 x 250
MC0024
Plastic Capillary Tubes, min. 130 µL 4)
6 I.E. Na heparin,
9 I.E. Li heparin/100µL
10 x 100
MC0026
25 x 1
CH9930
Plastic Capillary Tubes, min. 50 µl
24 I.E. Na-heparin/100µl
for pH/ blood gas analysis
special heparinized for fetal
sampling, sterile, individually
packed
1) 2) 3) 4)
18
for pH/blood gas-, electrolyte (except lithium), oximetry- and metabolite
analysis
SAMPLE COLLECTION DEVICES
À AVL Microsampler
A simple and safe accessory for
atraumatic, arterial blood collection.
Description
AVL Microsampler - with needle, sterile
min. 220 µL
6 I.E. Na heparin,
9 I.E. Li heparin/100µL
for pH/blood gas-, electrolyte
(except lithium), oximetry- and
metabolite analysis
AVL Microsampler - with needle, not sterile
min. 220 µL
6 I.E. Na heparin,
9 I.E. Li heparin/100µL
for pH/blood gas-, electrolyte
(except lithium), oximetry- and
metabolite analysis
AVL Microsampler - with needle, not sterile
Contents
Order No.
50 pcs.
MC0017
300 pcs.
MC0015
50 pcs.
MC0013
50 pcs.
CH0073*
min. 220 µL
6 I.E. Na-heparin,
9 I.E. Li-heparin/100µL
for pH/blood gas-, electrolyte
(except lithium), oximetry- and
metabolite analysis
AVL Microsampler - with needle, sterile
min. 220 µl
6 I.E. Na-heparin,
9 I.E. Li-heparin/100µL
for pH/blood gas-, electrolyte
(except lithium), oximetry- and
metabolite analysis
AVL Microsampler - without needle, not sterile
* Only
available in
France and
Switzerland
500 pcs.
CH0077
min. 220 µL
6 I.E. Na-heparin,
9 I.E. Li-heparin/100µl
for pH/blood gas-, electrolyte
(except lithium), oximetry- and
metabolite analysis
PRODUCT OVERVIEW
19
SAMPLE COLLECTION DEVICES
À AVL Syringes
Due to a special heparin coating, AVL
syringes are especially suited for pH /
blood gas-, electrolyte and metabolite
analysis.
Description
BS 2 - Blood Sampler
specified fill volume: 0,6 – 2 mL
30 I.E. Electrolyte-compensated
Contents
Order No.
1000 pcs.
MC0028
Na-heparin solution, suited for
analysis of all electrolytes
(sodium, potassium, calcium,
chloride, lithium and magnesium),
as well as for pH/blood gas-,
oximetry- and metabolite analysis.
NOTE:
20
Due to the current patent situation not approved for sale in Denmark
and the USA!
ACCESSORIES
À AVL Printer Paper
À AVL Calibration Gases
À AVL Clot Catcher
À Sample Cups for ISE Auto Sampler
À Adapters for Capillaries
À AVL Adapter for Sample Containers
À AVL Ampoule Adapter
À Caps for Capillary Tubes
À Caps for AVL Microsampler
À Bloodlancet
À Rubber Cubes for needles
À Needles (Terumo)
À Capillary Holder for fetal scalp sampling
À Capillary Holder for fetal scalp sampling
PRODUCT OVERVIEW
21
ACCESSORIES
À AVL PRINTER PAPER
The dimensions (length, width and diameter) and the quality of AVL printer paper
were designed to meet the requirements of the AVL instruments and thus ensure
optimal printer function.
v AVL Blood Gas
Instruments
Contents
Order No.
AVL COMPACT 1, 2, 3,
AVL 99X (new)
AVL OPTI
length: approx. 30 m
width: 58 mm
10 rolls
HP0070
AVL 99X (old)
length: approx. 25 m
width: 72 mm
10 rolls
HP0001
Contents
Order No.
v AVL Electrolyte
Instruments
Dimensions
AVL 98X, AVL 988-X
length: approx. 8 m
width: 37,8 mm)
10 rolls
HP0028
AVL 9100
length: approx. 8 m
width: 36,6 mm
5 rolls
BP5025
Contents
Order No.
6 rolls
HP0107
Contents
Order No.
10 rolls
HP0070
v AVL OMNI
AVL OMNI
v AVL OPTI
AVL OPTI 1
AVL OPTI CCA
22
Dimensions
Dimensions
length: approx. 50 m
width: 111,5 mm
Dimensions
length: approx. 30 m
width: 58 mm
ACCESSORIES
À AVL Calibration Gases
v AVL 99X
Contents
Order No.
1 bottle
HL0002
Silica-Gel (small),
Refill for drying cartridge BP0286,
fill volume approx. 25 mL
1 package
BP0345
Silica-Gel (large)
Refill for drying cartridge MY0083,
fill volume approx. 130 mL
1 package
HC0048
Silica-Gel
Refill for compressor MY0058,
fill volume approx. 300 mL
1 package
HC0056
1 bottle
1 bottle
1 bottle
HL0008
HL0020
HL0022
1 bottle
1 bottle
1 bottle
HL0010
HL0021
HL0023
1 pc.
ND0034
Contents
Order No.
1 bottle
BP7001
10 litre (CO 2 ) (refillable)
v AVL COMPACT 1, 2, 3
Calibration
3.5 litre
2 litre
3 litre
Calibration
3.5 litre
2 litre
3 litre
gas 1 (5.5% CO 2 , 20 % O 2 , balance N 2 )
(disposable)
(disposable)
(refillable)*
gas 2 (10 % CO 2 , balance N 2 )
(disposable)
(disposable)
(refillable)*
Gasket for pressure regulator
* Not available in all countries
v AVL OPTI 1 and AVL OPTI CCA
200 mL calibration gas
2 litre (140 psi, 9.7 bar)
PRODUCT OVERVIEW
23
ACCESSORIES
À AVL Clot Catcher
The AVL Clot Catcher prevents blood clots and
tissue particles from entering the analyzer.
Contents
Order No.
1 Box
(250 pcs.)
BP2243
Contents
Order No.
Cups for ISE Auto Sampler (0,5 mL)
1 Box
(500 pcs.)
BP1403
Cups for ISE Auto Sampler (1,5 mL)
1 Box
(500 pcs.)
BP1404
AVL Clot Catcher, disposable
À Sample Cups
for ISE Auto Sampler
(0.5 / 1.5 mL)
24
ACCESSORIES
À AVL Adapter
for Capillaries
AVL Adapter for Capillaries
Adapter for sample introduction in pH / blood gas
instruments.
AVL Adapter for Capillaries
Adapter for sample introduction in electrolyte
instruments (98X and 988-3/4).
PRODUCT OVERVIEW
Contents
Order No.
1 Box
(1000 pcs.)
BP0959
Contents
Order No.
1 Box
(1000 pcs.)
YA0529
25
ACCESSORIES
À
Adapter for sample containers
(not heparinized)
AVL Adapter for direct sample introduction from
vacutainer or bottles (e.g. AVL Deproteinizer)
Adapter for sample containers, disposable
Contents
Order No.
1 Box
(250 pcs.)
BP2277
Contents
Order No.
1 Box
(150 pcs.)
BP1938
À AVL Ampoule Adapter
(not heparinized)
AVL ampoule adapter for direct aspiration of
quality control and calibration solutions from
ampoules into the instrument.
AVL Ampoule Adapter, disposable
26
ACCESSORIES
À
Caps
for Capillary Tubes
To seal capillary samples for storage after
collection.
Caps for Capillary Tubes
À
Caps
Contents
Order No.
1 Box
(500 pcs.)
RE0410
Contents
Order No.
1 Box
(300 pcs.)
BP2288
for AVL Microsampler
To seal the AVL Microsampler for storage after
collection.
Caps for AVL Microsampler
PRODUCT OVERVIEW
27
ACCESSORIES
À
Bloodlancet,
disposable, sterile
Bloodlancet
À
Rubber Cubes
Contents
Order No.
1 Box
(200 pcs.)
MC0003
Contents
Order No.
1 pack
(50 pcs.)
CH0081
for a safe disposal of
needles
Rubber Cubes
28
ACCESSORIES
À
Needles (Terumo),
individually packed,
sterile
26 G x 23 mm, Luer
Needles (Terumo), individually packed, sterile
À
Capillary Holder
Contents
Order No.
1 Box
(100 pcs.)
CH5600
Contents
Order No.
1 pc.
CH9938
Contents
Order No.
1 pc.
CH9924
for fetal scalp
sampling, sterile
Capillary Holder, sterile
À
Capillary Holder for fetal scalp
sampling, autoclaveable
Capillary Holder, autoclaveable
PRODUCT OVERVIEW
29
AVL List GmbH
MEDIZINTECHNIK
Hans-List-Platz 1, P.O. Box 15
A-8020 Graz / Austria
AVL MEDICAL INSTRUMENTS AG
Stettemerstrasse 28, P.O. Box 1140
CH-8207 Schaffhausen/Switzerland
AVL SCIENTIFIC CORPORATION
33 Mansell Court, P.O. Box 337
Roswell, GA 30077, USA
PD0053, Rev. 3.0
KGa/MK, November 1998
INTENDED USE FOR SALES AND SERVICE!