avl reagents
Transcription
avl reagents
CONSUMABLES FOR AVL INSTRUMENTS - PRODUCT OVERVIEW INTENDED USE FOR SALES AND SERVICE! PD0053 REV. 3.0 CONTENTS Page REAGENTS .............................................................. 1 QUALITY CONTROL MATERIAL .............................. 6 ELECTRODES / SENSORS / OPTODES................. 10 SAMPLE COLLECTION DEVICES .......................... 17 ACCESSORIES ...................................................... 21 Note To guarantee long-term reliability and accuracy of AVL instruments, we recommend using AVL reagents, AVL electrodes and AVL accessories exclusively. They have been designed specifically for use in AVL instruments and take into consideration all requirements of the AVL instruments to ensure correct and reproducible measurement results. The preservatives, wetting and cleaning agents contained in AVL reagents were optimally balanced to meet the requirements of AVL instruments and electrodes. Electrode cleaning and conditioning in the instruments is achieved optimally by using the AVL reagents designed and optimized specifically for this purpose. The heparin types and concentrations used in AVL capillary tubes to prevent blood clotting were selected specifically to meet the requirements of blood gas, electrolyte and metabolite analysis to eliminate any deviation of measured values. The volume of the AVL capillary tubes has been adjusted to meet the requirements of the respective instruments and thus allows collection of the required sample volume. The outer diameter of the AVL capillary tubes was designed to fit the sample fill port of the AVL instruments and the capillary tips have been polished to prevent injury or damage to the fill port. The combined use of AVL reagents, AVL electrodes and AVL accessories was tested intensively and thus ensures optimal operation of the AVL instruments. QUALITY CERTIFICATE - AVL REAGENTS Our Quality Assurance System complies with the requirements of the ÖNORM EN ISO 9001. The water used for the production of AVL Reagents undergoes multilevel processing and is therefore of the highest quality. It has an initial conductivity of < 0.3 µS/cm and is sterile and pyrogen-free. AVL Reagents are produced in accordance with manufacturers‘ specifications. The raw materials and testing devices used are traceable to N.I.S.T. StandardMaterials. The consistent quality of the AVL reagents is ensured by strict adherence to testing protocols during production and testing of samples at periodic intervals. AVL Reagents are being tested with regard to hazardous properties in accordance with the Austrian Chemical Substances Law and the pertinent EC – Guidelines. ENVIRONMENTAL PROTECTION THE GREEN DOT - For years AVL has played an active role in the protection of the environment by using recyclable and biologically safe packing materials. AVL also participates in the Dual System (THE GREEN DOT) to demonstrate a positive attitude towards a substantial reduction and avoidance of packaging waste to protect the environment. USE OF AVL REAGENTS ENSURES CONSISTENT QUALITY To ensure reliability and precision of AVL instruments for the long term, we recommend the exclusive use of AVL Reagents. They have been designed specifically for use in AVL instruments and meet all requirements of the AVL instruments to ensure correct and reproducible measurement results. The preservatives, wetting- and cleaning agents contained in AVL Reagents are optimally balanced and meet the requirements of AVL instruments and electrodes. Electrode conditioning and maintenance in the instrument is optimized by use of AVL Reagents. The interaction of AVL Reagents and AVL Electrodes has been tested intensively and thus ensures optimal functioning of AVL instruments. REAGENTS All reagents listed below are for diagnostic in-vitro use exclusively. À AVL Blood Gas Instruments v AVL 99X-/94X-Instruments (AVL 995-Hb, 995, 993, 990 AVL 947, 945, 940) Contents Buffer Type 1 (pH 7.383) Buffer Type 2 (pH 6.841) pH Reference Solution (0.6 mol/L KCl) Cleaning Solution Rinse Rinse Additive Deproteinizer tHb Calibrator P CO 2 /TCO 2 Filling Solution P O 2 Filling Solution Disposable Waste Bottle with cap 3x90 3x90 3x90 125 6x430 100x1 125 5x2 125 125 20 mL mL mL mL mL mL mL mL mL mL pcs. Order-No. BP0136 BP0137 BP0134 BP1303 BP1890 BP0337 BP0521 BP1360 BP1286 BP1414 BP1502 1 REAGENTS À AVL Blood Gas Instruments v AVL COMPACT 1, AVL COMPACT 2, AVL COMPACT 3 Buffer Type 1 (pH 7.383) (AVL COMPACT 1, 2, 3) Buffer Type 2 (pH 6.841) (AVL COMPACT 2, 3) pH Reference Solution (0.6 mol/L KCl) Cleaning Solution Cleaning Solution (AVL COMPACT 2, 3) Rinse Rinse Additive Deproteinizer BG Calibrator including adapter (AVL COMPACT 1) P CO 2 /TCO 2 Filling Solution P O 2 Filling Solution Disposable Waste Bottle with cap Contents Order No. 3x90 mL 3x90 mL 3x90 mL 125 mL 3x90 mL 6x430 mL 100x1 mL 125 mL 30x2 mL 125 mL 125 mL 20 pcs. BP0136 BP0137 BP0134 BP1303 BP1889 BP1890 BP0337 BP0521 BP1579 BP1286 BP1414 BP1502 Contents Order No. 30x4 mL 5 x 2 mL 125 mL BP1564 BP1360 BP0521 À AVL CO-Oximetry Instruments v AVL 912 CO-Ox Zero Rinse Additive tHb Calibrator Deproteinizer 2 REAGENTS À AVL Electrolyte Instruments v AVL 98X (980, 982 –987), AVL 988-X (988-3/4) Standard A (for AVL 980 Cl, 982, 983, 985, AVL 988-3 Cl/Li) Standard A (for AVL 984, 987, 988-3 Ca, 988-4 K) Standard A ( for AVL 980 Ca) Standard A ( for AVL 986) Standard A ( for AVL 988-4 Mg) Standard B (for AVL 980 Ca, 980 Cl, 982, 983) Standard B (for AVL 985, 988-3 Cl/Li) Standard B ( for AVL 984, 987, 988-3 Ca, 988-4 K) Standard B ( for AVL 986) Standard B ( for AVL 988-4 Mg ) Standard C ( for AVL 985, 988-3 Li) Standard C (for AVL 988-4 Mg) Standard D ( for AVL 988-4 Mg) Reference Solution ( 1.2 mol/L KCl) Contents 3x430 3x430 3x430 3x90 3x430 3x90 3x90 3x90 3x90 3x90 3x90 3x90 3x50 3x90 Order-No. mL mL mL mL mL mL mL mL mL mL mL mL mL mL BP0936 BP1232 BP0332 BP1203 BP1598 BP0442 BP0937 BP1218 BP1201 BP1599 BP0938 BP1600 BP1601 BP0095 3x90 mL 125 mL 125 mL 3x430 mL 125 mL 125 mL 25 mL 25 mL BP1774 BP1607 BP1225 BP1200 BP0521 BP0380 BP1052 BP1053 125 mL 500 mL 500 mL BP1286 BP0344 BP1405 (for AVL 98X and AVL 988-X except 988-4 Mg) Reference Solution 2 ( for AVL 988-4 Mg) Cleaning Solution ( for electrolyte systems) Cleaning Solution ( for AVL 986) Releasing Agent (for AVL 986) Deproteinizer Sodium Electrode Conditioner Electrode Filling Solution for Na + Electrode Filling Solution for K + , Cl - , Ca ++ , Li + and pH P CO 2 /TCO 2 Filling Solution Urine Diluent Urine Diluent (for AVL 986) PRODUCT OVERVIEW 3 REAGENTS À AVL Electrolyte Instruments v AVL 91XX Snap Pack (9120, 9130) Snap Pack (9110, 9140) Snap Pack (9180, 9181) Cleaning Solution (for electrolyte systems) Sodium Electrode Conditioner Deproteinizer Electrode Filling Solution for Na + Electrode Filling Solution for K + , Cl - , Ca ++ , Li + and pH Urine Diluent 4 Contents 1 1 1 125 125 125 25 25 500 pc. pc. pc. mL mL mL mL mL mL Order No. BP5016 BP5032 BP5186 BP1607 BP0380 BP0521 BP1052 BP1053 BP0344 REAGENTS À AVL OMNI Instruments Description AVL OMNI Solution AVL OMNI Solution AVL OMNI Solution AVL OMNI Solution AVL OMNI Solution AVL OMNI Solution AVL OMNI Solution AVL OMNI Solution AVL OMNI Solution AVL OMNI Solution AVL OMNI Solution AVL OMNI Solution AVL OMNI Solution AVL OMNI Solution Deproteinizer tHb Calibrator NOTE: A B C D (GLU/LAC) D (GLU/LAC/UREA) R 1 (GLU/LAC) 1 (GLU/LAC/UREA) 2 3 (GLU/LAC) 3 (GLU/LAC/UREA) 4 5 (GLU/LAC) 5 (GLU/LAC/UREA) Contents Order No. 6x820 mL 6x820 mL 6x480 mL 6x480 ml 6x480 ml 12x100 ml 4x40 ml 4x38 ml 4x40 ml 4x40 ml 4x38 ml 4x40 ml 6x100 ml 6x98 ml 125 mL 5x2 mL BP1893 BP1892 BP1891 BP2279 BP2191 BP1894 BP2248 BP2192 BP1898 BP2249 BP2193 BP2068 BP2278 BP2194 BP0521 BP1360 - AVL OMNI Solutions B and C must always be replaced together. - To reduce waste products, empty Solution A and B bottles may be used as waste containers. v Waste Container Waste Container Reusable Waste Container 6x820 mL 1x820 mL BP1895 BP2257 External Waste Container System: External Waste Container Waste Collector for AVL OMNI Accessories for External Waste Container 2x4 L 1x820 mL 1 pc. BP2419 BP2417 BP2407 2x180 mL 2x180 mL BP2424 BP2425 v AVL MSS Conditioning System GLU/LAC Conditioning Solution GLU/LAC/UREA Conditioning Solution PRODUCT OVERVIEW 5 QUALITY CONTROL MATERIAL À ISE-trol À COMBI-trol À COMBI-trol PLUS À AUTO-trol COMBI À AUTO-trol PLUS À CONFITEST III À CONFITEST CO-Ox À OPTI-trol À OPTI-check 6 QUALITY CONTROL MATERIAL À ISE-trol Description uncolored electrolyte solution Parameters Levels electrolytes: Level 1: Na + , K + , Cl - , Ca ++ , Level 2: normal values + ++ Li , Mg , TCO 2 , Level 3: pH + + + - ++ Order No. Contents HC0033 3x12x1.0 mL ampoules ++ Level 1: low values for Na , K , Li , Cl ; high values for Ca , Mg ++ ++ + + + Level 3: low values for Ca , Mg ; high values for Na , K , Li , Cl , normal TCO 2 À COMBI-trol Description colored aqueous solution Parameters Levels pH/blood gases: Level 1: pH, P O 2 , P CO 2, Level 2: normal values electrolytes: Level 3: + + ++ Na , K , Cl , Ca , + Li , TCO 2 tHb, Hb-derivatives : O 2 Hb, COHb, HHb MetHb, SulfHb + + - + Order No. Contents HC0071 HC0072 HC0073 30x1.7 mL ampoules ++ Level 1: respiratory acidosis, low values P O 2 , Na , K , Cl , Li , high values for Ca and tHb + + + ++ Level 3: respiratory alkalosis, high values P O 2 , Na , K , Cl , Li , low values for Ca and tHb À COMBI-trol PLUS Description colored aqueous solution Parameters Levels pH/blood gases: Level 1: pH, P O 2 , P CO 2, Level 2: normal values electrolytes : Level 3: Na + , K + , Cl - , Ca ++ , + Li , TCO 2 tHb, Hb-derivatives : O 2 Hb, COHb, HHb MetHb, SulfHb metabolites : Glu, Lac, Urea + + - Order No. Contents HC9038 HC9039 HC9040 30x1.7 mL ampoules ++ + Level 1: respiratory acidosis, low values for P O 2 , Na , K , Cl , Glu and tHb, high values for Ca , Li , Lac and Urea + + ++ + Level 3: respiratory alkalosis, high values for P O 2 , Na , K , Cl , Glu and tHb, low values for Ca , Li , Lac and Urea PRODUCT OVERVIEW 7 QUALITY CONTROL MATERIAL À AUTO-trol COMBI Description colored aqueous solution Parameters Levels pH/blood gases : Level 1: pH, P O 2 , P CO 2, Level 2: normal values electrolytes : Level 3: + + ++ Na , K , Cl , Ca tHb, Hb-derivatives: O 2 Hb, COHb, HHb MetHb, SulfHb + + - Order No. Contents HC9032 HC9033 HC9034 2 mats (20x1.6 mL ampoules) ++ Level 1: respiratory acidosis, low values P O 2 , Na , K , Cl , high values for Ca and tHb + + ++ Level 3: respiratory alkalosis, high values for P O 2 , Na , K , Cl , low values for Ca and tHb À AUTO-trol PLUS Description colored aqueous solution Parameters Levels pH/blood gases: Level 1: pH, P O 2 , P CO 2, Level 2: normal values electrolytes : Level 3: + + ++ Na , K , Cl , Ca tHb, Hb-derivatives : O 2 Hb, COHb, HHb MetHb, SulfHb metabolites : Glu, Lac, Urea + + - Order No. Contents HC9041 HC9042 HC9043 2 mats (20x1.6 mL ampoules) ++ Level 1: respiratory acidosis, low values for P O 2 , Na , K , Cl , Glu and tHb, high values for Ca , Lac and Urea + + ++ Level 3: respiratory alkalosis, high values for P O 2 , Na , K , Cl , Glu and tHb, low values for Ca , Lac and Urea 8 QUALITY CONTROL MATERIAL À CONFITEST III Description uncolored, aqueous solution Parameters pH/blood gases : pH, P O 2 , P CO 2 Levels Level Level Level Level Level 1: acidosis 2: normal values 3: alkalosis 4: high P O 2 1-3 Order No. Contents HC9027 HC9028 HC9029 HC9030 HC0049 30x1.7mL ampoules 3x12x1.7mL ampoules À CONFITEST CO-Ox Description bovine blood based solution Parameters Levels Order No. Contents US0811 US0812 US0813 30x1.2mL ampoules Levels Order No. Contents Level 1: acidosis Level 2: normal values Level 3: alkalosis HC7001 HC7002 HC7003 30x1.7 mL ampoules Order No. Contents HC7008 3x10x1.7 mL ampoules tHb, Hb-derivatives : Level 1: low tHb O 2 Hb, COHb, HHb Level 2: normal tHb MetHb, SulfHb Level 3: high tHb À OPTI-trol (for AVL OPTI 1) Description uncolored, aqueous solution Parameters pH/blood gases: pH, P O 2 , P CO 2 À OPTI-check (for AVL OPTI CCA) Description aqueous solution Parameters pH/blood gases: pH, P O 2 , P CO 2 electrolytes: Na + , K + tHb, SO 2 PRODUCT OVERVIEW Levels Level 1 - Level 3 9 ELECTRODES / SENSORS / OPTODES À AVL Blood Gas Electrodes v zero-maintenance v remembranable À AVL Electrolyte Electrodes v screw type v sealed type À AVL OMNI Micro-Electrodes v Blood gas v Electrolyte À AVL OMNI Metabolite Sensors v Glu v Glu/Lac v Glu/Lac/Urea À AVL Optodes v AVL OPTI cassettes 10 ELECTRODES / SENSORS / OPTODES À AVL Blood Gas Electrodes For instruments of the 94X, 99X and COMPACT series, you may choose between two different electrode types: • • zero-maintenance electrodes remembranable electrodes v Zero-maintenance Electrodes Features and Benefits Simple • Truly maintenance free pH, P CO 2 and P O 2 electrodes. After placing the electrodes into the measuring chamber absolutely no user manipulation required. Time saving • • • No remembraning procedure. No scheduled debubbeling procedures. No top up of electrode solution required. The pH-reference electrode is selffilling. Flexible • Fully operational in all AVL blood gas analyzers (AVL 94X, AVL 99X, AVL COMPACT). A combination of zero-maintenance electrodes and remembranable electrodes in one analyzer is possible. This makes the step-by-step upgrade without financial loss possible. • • Reliable NOTE: Expected lifetime of about 1.5 years for all zero-maintenance electrodes. AVL zero-maintenance electrodes require no maintenance operation and best performance of the AVL zero-maintenance electrodes will be achieved following the advices below. Once in place, the electrodes should not be removed until it is to be replaced, even not for cleaning of the measuring chamber. Avoid contact with hard surfaces and take care not to strike the rear of the measuring chamber Repeated handling increases the risk of damaging the electrode membrane. PRODUCT OVERVIEW 11 ELECTRODES / SENSORS / OPTODES À AVL Blood Gas Electrodes v Remembranable Electrodes Features and Benefits Long term cost saving Flexible Reliable NOTE: . 12 • Conscientious electrode maintenance prolongs the lifetime of electrodes considerably. • Fully operational in all AVL blood gas analyzers (AVL 94X, AVL 99X, AVL COMPACT). • A combination of zero-maintenance electrodes and remembranable electrodes in one analyzer is possible. This makes step-by-step upgrade possible, without financial loss. • Expected lifetime of remembranable electrodes is 2 to 3 years. When treated accordingly, one of the biggest advantages of the AVL remembranable electrodes is their extended lifetime. Regulare and careful maintenance of the electrodes assures the quality of measurement results and extends the lifetime considerably. Please follow the instructions given in the section "Maintenance" of the Operator’s Manuals of AVL blood gas analyzers. ELECTRODES / SENSORS / OPTODES À AVL Blood Gas Electrodes Description pH Electrode (zero-maintenance) P CO 2 Electrode (zero-maintenance) P O 2 Electrode (zero-maintenance) pH Electrode (remembranable) P CO 2 Electrode (remembranable) P O 2 Electrode (remembranable) pH Reference Electrode pH Reference Electrode (for AVL 94x and AVL 93x) pH Reference Housing pH Electrode Housing P CO 2 Membrane Housing P O 2 Membrane Housing Electrode Cleaning Pad Coroplast Cleaning Paste Cable for Zero-Maintenance Electrodes Dummy Electrodes Parafilm PRODUCT OVERVIEW Contents Order No. 1 pc. 1 pc. 1 pc. 1 pc. 1 pc. 1 pc. 1 pc. 1 pc. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 1 pc. 1 pc. 1 tube 1 pc. 4 pcs. 30 x 10 cm BP1390 BP1389 BP1388 BP0357 BP0356 BP0355 BP1044 BP0354 BP1090 YB0735 YB0733 YB0732 YB0731 SK0188 HC0012 BV1320 YB0730 BP0389 13 ELECTRODES / SENSORS / OPTODES À AVL Electrolyte Electrodes You may choose between two different types of electrodes: • AVL zero-maintenance electrolyte electrodes (sealed type) • AVL refillable electrolyte electrodes (screw type) v AVL Electrolyte Instruments (AVL 98X, 988-X, 91XX) Contents Order No. Na + Electrode (sealed-type) K + Electrode (sealed-type) Cl - Electrode (sealed-type) ++ Ca Electrode (sealed-type) Li + Electrode (sealed-type) Mg ++ Electrode (sealed-type) Na + Electrode (screw-type) * K + Electrode (screw-type) * Cl - Electrode (screw-type) * Ca ++ Electrode (screw-type) * pH Electrode Housing Ag/AgCl Electrode (for pH electrode) Reference Electrode (for AVL 98X and 988-X) Reference Electrode Housing (for AVL 98X and 988-X) Electrode Cable (for AVL 98X and 988-X) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. BP0413 BP0359 BP0570 BP0360 BP0962 BP1597 BP0829 BP0824 BP0823 BP0932 BP1237 BP1033 BP0713 BP0844 BP0349 Reference Electrode (for AVL 91XX instruments) Reference Electrode Housing (for AVL 91XX instruments) 1 pc. 1 pc. BP5026 BP5019 Dummy Electrode 1 pc. BP0148 * Not available in all countries 14 ELECTRODES / SENSORS / OPTODES À AVL OMNI Micro-Electrodes The AVL OMNI Micro-Electrodes represent a new generation of sensors optimized with regard to minimal sample volume and zero maintenance. All electrodes are flow-through electrodes with visible sample channel. v AVL OMNI Cl - Electrode Na + Electrode K + Electrode Ca ++ Electrode P CO 2 Electrode P O 2 Electrode pH Electrode Ref Electrode Junction Electrode Dummy Electrode AVL OMNI ISE Electrode Kit + + ++ - (Na , K , Ca , Cl , Ref., Jun) AVL OMNI BG Electrode Kit Contents 1 1 1 1 1 1 1 1 1 1 pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. BP1729 BP1730 BP1731 BP1732 BP1733 BP1734 BP1735 BP2081 BP2082 BP1959 1 Box BP2006 (1 pc. / type) 1 Box (pH, P O 2 , P CO 2 , Ref., Jun.) (1 pc. / type) Cl-Cleaning Kit 1 package PRODUCT OVERVIEW Order No. BP2007 BP2276 15 ELECTRODES / SENSORS / OPTODES À AVL OMNI Metabolite Sensors The new AVL thick-film technology allows for an entirely new way of producing glucose/lactate/urea sensors in one cassette. AVL metabolite cassettes are absolutely maintenance-free and easy to replace. v AVL OMNI Contents Order No. Glucose Cassette Glucose/Lactate Cassette Glucose/Lactate/Urea Cassette 1 pc. 1 pc. 1 pc. BP2094 BP2096 BP2093 RCon (Reference Contact) MSS Dummy Cassette 1 pc. 1 pc. BP2258 BP2284 À AVL Optodes v AVL OPTI Contents AVL OPTI 1 Cassette Order No. 25 pcs. BP7508 25 pcs. BP7562 25 pcs. BP7558 1 pc. BP7536 1 pc. BP7554 1 pc. BP7543 (pH, P O 2 , P CO 2 ) AVL OPTI CCA Sensor Cassette B (pH, P O 2 , P CO 2 , tHb, SO 2 ) AVL OPTI CCA Sensor Cassette E + + (pH, P O 2 , P CO 2 , tHb, SO 2 , Na , K ) Standard Reference Cassette low (for AVL OPTI 1 and AVL OPTI CCA) Standard Reference Cassette normal (for AVL OPTI 1 and AVL OPTI CCA) Standard Reference Cassette high (for AVL OPTI 1 and AVL OPTI CCA) 16 SAMPLE COLLECTION DEVICES À AVL Capillary Tubes À AVL Microsampler À AVL Syringe Note: Lithium- or sodium heparin or a balanced heparin mixture is the only permissible anticoagulants for blood gas and electrolyte analysis. Other anticoagulants such as EDTA, citrate, oxalate and fluoride have a significant impact on some of the measurement parameters and should not be used. PRODUCT OVERVIEW 17 SAMPLE COLLECTION DEVICES À AVL Capillary Tubes Due to a special heparin coating, AVL capillaries are especially suited for pH / blood gas-, electrolyte and metabolite analysis. Description Contents Order No. Glass Capillary Tubes, min. 115 µL 1) 6 I.E. Na heparin, 9 I.E. Li heparin/100µL 4 x 250 MG0002 Glass Capillary Tubes, min. 115 µL 9 I.E. Na heparin, 6 I.E. ammonium heparin/100µL for electrolyte analysis 4 x 250 MG0023 Glass Capillary Tubes, min. 115 µL 24 I.E. Na heparin/100µL for pH/ blood gas analysis special heparinized for fetal sampling 4 x 250 CH2045 Glass Capillary Tubes, min. 180 µL 2) 6 I.E. Na heparin, 9 I.E. Li heparin/100µL 4 x 250 MC0020 Glass Capillary Tubes, min. 200 µL 3) 6 I.E. Na heparin, 9 I.E. Li heparin/100µL 4 x 250 MC0024 Plastic Capillary Tubes, min. 130 µL 4) 6 I.E. Na heparin, 9 I.E. Li heparin/100µL 10 x 100 MC0026 25 x 1 CH9930 Plastic Capillary Tubes, min. 50 µl 24 I.E. Na-heparin/100µl for pH/ blood gas analysis special heparinized for fetal sampling, sterile, individually packed 1) 2) 3) 4) 18 for pH/blood gas-, electrolyte (except lithium), oximetry- and metabolite analysis SAMPLE COLLECTION DEVICES À AVL Microsampler A simple and safe accessory for atraumatic, arterial blood collection. Description AVL Microsampler - with needle, sterile min. 220 µL 6 I.E. Na heparin, 9 I.E. Li heparin/100µL for pH/blood gas-, electrolyte (except lithium), oximetry- and metabolite analysis AVL Microsampler - with needle, not sterile min. 220 µL 6 I.E. Na heparin, 9 I.E. Li heparin/100µL for pH/blood gas-, electrolyte (except lithium), oximetry- and metabolite analysis AVL Microsampler - with needle, not sterile Contents Order No. 50 pcs. MC0017 300 pcs. MC0015 50 pcs. MC0013 50 pcs. CH0073* min. 220 µL 6 I.E. Na-heparin, 9 I.E. Li-heparin/100µL for pH/blood gas-, electrolyte (except lithium), oximetry- and metabolite analysis AVL Microsampler - with needle, sterile min. 220 µl 6 I.E. Na-heparin, 9 I.E. Li-heparin/100µL for pH/blood gas-, electrolyte (except lithium), oximetry- and metabolite analysis AVL Microsampler - without needle, not sterile * Only available in France and Switzerland 500 pcs. CH0077 min. 220 µL 6 I.E. Na-heparin, 9 I.E. Li-heparin/100µl for pH/blood gas-, electrolyte (except lithium), oximetry- and metabolite analysis PRODUCT OVERVIEW 19 SAMPLE COLLECTION DEVICES À AVL Syringes Due to a special heparin coating, AVL syringes are especially suited for pH / blood gas-, electrolyte and metabolite analysis. Description BS 2 - Blood Sampler specified fill volume: 0,6 – 2 mL 30 I.E. Electrolyte-compensated Contents Order No. 1000 pcs. MC0028 Na-heparin solution, suited for analysis of all electrolytes (sodium, potassium, calcium, chloride, lithium and magnesium), as well as for pH/blood gas-, oximetry- and metabolite analysis. NOTE: 20 Due to the current patent situation not approved for sale in Denmark and the USA! ACCESSORIES À AVL Printer Paper À AVL Calibration Gases À AVL Clot Catcher À Sample Cups for ISE Auto Sampler À Adapters for Capillaries À AVL Adapter for Sample Containers À AVL Ampoule Adapter À Caps for Capillary Tubes À Caps for AVL Microsampler À Bloodlancet À Rubber Cubes for needles À Needles (Terumo) À Capillary Holder for fetal scalp sampling À Capillary Holder for fetal scalp sampling PRODUCT OVERVIEW 21 ACCESSORIES À AVL PRINTER PAPER The dimensions (length, width and diameter) and the quality of AVL printer paper were designed to meet the requirements of the AVL instruments and thus ensure optimal printer function. v AVL Blood Gas Instruments Contents Order No. AVL COMPACT 1, 2, 3, AVL 99X (new) AVL OPTI length: approx. 30 m width: 58 mm 10 rolls HP0070 AVL 99X (old) length: approx. 25 m width: 72 mm 10 rolls HP0001 Contents Order No. v AVL Electrolyte Instruments Dimensions AVL 98X, AVL 988-X length: approx. 8 m width: 37,8 mm) 10 rolls HP0028 AVL 9100 length: approx. 8 m width: 36,6 mm 5 rolls BP5025 Contents Order No. 6 rolls HP0107 Contents Order No. 10 rolls HP0070 v AVL OMNI AVL OMNI v AVL OPTI AVL OPTI 1 AVL OPTI CCA 22 Dimensions Dimensions length: approx. 50 m width: 111,5 mm Dimensions length: approx. 30 m width: 58 mm ACCESSORIES À AVL Calibration Gases v AVL 99X Contents Order No. 1 bottle HL0002 Silica-Gel (small), Refill for drying cartridge BP0286, fill volume approx. 25 mL 1 package BP0345 Silica-Gel (large) Refill for drying cartridge MY0083, fill volume approx. 130 mL 1 package HC0048 Silica-Gel Refill for compressor MY0058, fill volume approx. 300 mL 1 package HC0056 1 bottle 1 bottle 1 bottle HL0008 HL0020 HL0022 1 bottle 1 bottle 1 bottle HL0010 HL0021 HL0023 1 pc. ND0034 Contents Order No. 1 bottle BP7001 10 litre (CO 2 ) (refillable) v AVL COMPACT 1, 2, 3 Calibration 3.5 litre 2 litre 3 litre Calibration 3.5 litre 2 litre 3 litre gas 1 (5.5% CO 2 , 20 % O 2 , balance N 2 ) (disposable) (disposable) (refillable)* gas 2 (10 % CO 2 , balance N 2 ) (disposable) (disposable) (refillable)* Gasket for pressure regulator * Not available in all countries v AVL OPTI 1 and AVL OPTI CCA 200 mL calibration gas 2 litre (140 psi, 9.7 bar) PRODUCT OVERVIEW 23 ACCESSORIES À AVL Clot Catcher The AVL Clot Catcher prevents blood clots and tissue particles from entering the analyzer. Contents Order No. 1 Box (250 pcs.) BP2243 Contents Order No. Cups for ISE Auto Sampler (0,5 mL) 1 Box (500 pcs.) BP1403 Cups for ISE Auto Sampler (1,5 mL) 1 Box (500 pcs.) BP1404 AVL Clot Catcher, disposable À Sample Cups for ISE Auto Sampler (0.5 / 1.5 mL) 24 ACCESSORIES À AVL Adapter for Capillaries AVL Adapter for Capillaries Adapter for sample introduction in pH / blood gas instruments. AVL Adapter for Capillaries Adapter for sample introduction in electrolyte instruments (98X and 988-3/4). PRODUCT OVERVIEW Contents Order No. 1 Box (1000 pcs.) BP0959 Contents Order No. 1 Box (1000 pcs.) YA0529 25 ACCESSORIES À Adapter for sample containers (not heparinized) AVL Adapter for direct sample introduction from vacutainer or bottles (e.g. AVL Deproteinizer) Adapter for sample containers, disposable Contents Order No. 1 Box (250 pcs.) BP2277 Contents Order No. 1 Box (150 pcs.) BP1938 À AVL Ampoule Adapter (not heparinized) AVL ampoule adapter for direct aspiration of quality control and calibration solutions from ampoules into the instrument. AVL Ampoule Adapter, disposable 26 ACCESSORIES À Caps for Capillary Tubes To seal capillary samples for storage after collection. Caps for Capillary Tubes À Caps Contents Order No. 1 Box (500 pcs.) RE0410 Contents Order No. 1 Box (300 pcs.) BP2288 for AVL Microsampler To seal the AVL Microsampler for storage after collection. Caps for AVL Microsampler PRODUCT OVERVIEW 27 ACCESSORIES À Bloodlancet, disposable, sterile Bloodlancet À Rubber Cubes Contents Order No. 1 Box (200 pcs.) MC0003 Contents Order No. 1 pack (50 pcs.) CH0081 for a safe disposal of needles Rubber Cubes 28 ACCESSORIES À Needles (Terumo), individually packed, sterile 26 G x 23 mm, Luer Needles (Terumo), individually packed, sterile À Capillary Holder Contents Order No. 1 Box (100 pcs.) CH5600 Contents Order No. 1 pc. CH9938 Contents Order No. 1 pc. CH9924 for fetal scalp sampling, sterile Capillary Holder, sterile À Capillary Holder for fetal scalp sampling, autoclaveable Capillary Holder, autoclaveable PRODUCT OVERVIEW 29 AVL List GmbH MEDIZINTECHNIK Hans-List-Platz 1, P.O. Box 15 A-8020 Graz / Austria AVL MEDICAL INSTRUMENTS AG Stettemerstrasse 28, P.O. Box 1140 CH-8207 Schaffhausen/Switzerland AVL SCIENTIFIC CORPORATION 33 Mansell Court, P.O. Box 337 Roswell, GA 30077, USA PD0053, Rev. 3.0 KGa/MK, November 1998 INTENDED USE FOR SALES AND SERVICE!
Similar documents
2015 wholesale pricebook - Star Spangled Novelties
All!items!are!sold!on!a!first!come!first!served!basis.!!No!items!will!be!held!without!full!payment.!!No! item(s)!will!be!shipped!without!full!payment!(including!shipping!costs).!!We!accept!cash,!cr...
More information