physical therapy

Transcription

physical therapy
PHYSICAL
THERAPY
LINE OF PRODUCTS
Expert
TECHNOLOGY FOR THERAPY
THERAPY UNITS
IONOSON-Expert
IONOSON-IF-Expert
PHYSIOMED-Expert
PHYSIOMED-Expert PhysioView
PHYSIOMED-IF-Expert
PHYSIOSON-Expert
PHYSIOVAC-Expert
LAS-Expert
PHYSIOTHERM-M
PHYSIOTHERM-S
FRIGOSTREAM
PORTRAIT
PHYSIOMED ELEKTROMEDIZIN AG
TECHNOLOGY FOR THERAPY
PHYSIOMED ELEKTROMEDIZIN AG is a leading producer of highquality equipment for traditional and innovative physical therapy.
The PHYSIOMED name stands for outstanding product quality,
cutting-edge technological solutions, and an outstanding priceperformance ratio.
The German company focuses on offering equipment for treatment in the fields of rehabilitation, sports, aesthetic medicine
and veterinary medicine. Its products range from equipment for
electrotherapy, ultrasound therapy, vacuum application therapy,
laser therapy, microwave therapy and shortwave therapy to cryotherapy and a range of completely new, clinically tested treatments such as DEEP OSCILLATION®, MAGCELL®, PSORIAMED®
and vocaSTIM®.
Official partner of the
German Ice Hockey Federation
and German National
Ice Hockey Team
PHYSIOMED ELEKTROMEDIZIN AG presently exports its products to more than 70 countries worldwide. At the same time, the
company, which is engaged in international research, maintains
numerous cooperative efforts with universities and the continuous exchange of information with renowned scientists and leading physicians. Our products‘ outstanding performance and suitability for daily use are based on over 35 years of experience and
continuous communication with working therapists.
We make every effort to keep our products safe for the patient
and the therapist, and to do this we make sure our safety functions go way beyond the official legal requirements. Our safety features serve as benchmarks, such as our emergency stop
pushbutton, the automatic current switch-off if an electrode
fails or the fixation of other parameters that change the current
strengths during intensity output.
Partner of the German
Handball Association
ISO 9001
Made in Germany
PHYSIOMED equipment corresponds to the latest safety standards and regulations of the Medical Device Ordinance, is manufactured in accordance with the current
quality assurance standards, is type-examination tested, and bears the CE Marking in accordance with Directive 93/42/EEC.
PAGE 3
SPECIFICATION
Expert-Line
Expert-Line
the exclusive line of products for classic physical therapy
The Expert-LINE units feature an appealing design, outstanding
quality and excellent user-friendliness.
You can quickly and safely navigate within the illuminated and
large LCD display using PHYSIOMED‘s unique one-button operation, which has proven itself for the last 15 years. To begin therapy, simply select the desired application directly from the top
menu level or simply select one of the numerous treatment suggestions from the extensive and alphabetised treatment index.
After you have selected the indication and confirmed your selection, you are then directed to the desired therapy including the
recommended dosage and graphic of the region to be treated.
You also have easy access to individually adjustable programs or
even pre-programmed program sequences. Electrotherapy allows the use of “potpourris”, which sequence up to three different currents per memory location and thus ensure a varied and
time-saving treatment.
The quality and safety of our accessories are also a top priority.
For example, the contact surfaces of our ultrasonic transducers
are made of biocompatible titanium (and not aluminium, which is
cheaper and more common) to prevent allergic reactions. Another example is our long-lasting plate or adhesive electrodes with
excellent conductivity. Our large selection of special accessories
for all professional physical therapy needs have proven themselves in practice for many years, and people enjoy using them.
Another advantage is that the Expert-Line electrotherapy, ultrasound and vacuum units are all compatible with one another.
Missing therapy forms can be easily added at any time to a representative mobile therapy station. Our customised Expert-Line
trolleys allow you to combine any therapy devices into complete
therapy units.
IONOSON-Expert combination therapy unit and PHYSIOVAC-Expert vacuum application unit
on an Expert trolley
PAGE 4
CONTENTS
Table of contents
Technology for Therapy PHYSIOMED ELEKTROMEDIZIN AG
Specification Expert-Line
Index 3
4
5
Combination therapy
IONOSON-Expert
IONOSON-IF-Expert
6-7
8-9
Electrotherapy
PHYSIOMED-Expert
PHYSIOMED-Expert PhysioView
PHYSIOMED-IF-Expert
10-11
12-13
13
14-15
Ultrasound therapy
PHYSIOSON-Expert
16-17
18-19
Vacuum application
PHYSIOVAC-Expert
20-21
22-23
Laser therapy
LAS-Expert
24-25
26-27
Microwave therapy
PHYSIOTHERM-M
28-29
30-31
Shortwave therapy
PHYSIOTHERM-S
32-33
34-35
Cryotherapy
FRIGOSTREAM
36-37
38-39
Additional accessories for electrotherapy
Further information
Currents of electrotherapy
40
41
42
PAGE 5
THERAPY ICON
THERAPY FORM
Combination therapy
IONOSON-Expert
Fast therapy start: direct, through program memory or indication index · Simultaneous therapy · Watertight and
biocompatible titanium transducers · TPS · 1 and 3 MHz in one ultrasound transducer · Two-channel electro­
therapy unit with all modern low-frequency and medium-frequency currents · Alternating and simultaneous
stimulation · Diagnostics
DEVICE DESCRIPTION
The versatile IONOSON-Expert combination unit combines all the
advantages of modern electrotherapy (two-channel) and diagnostics as well as ultrasound therapy in one unit, which ensures
that the patient will receive the best and most efficient treatment.
sive overview of the therapy parameters that are currently in use
including both therapy timers. The manual release key functions
on the one hand as a therapy cut-off key (emergency shut-off
switch) for the patient and also enables the use of intentional
exercises.
The IONOSON-Expert features all of the relevant low-frequency
and medium-frequency currents, which can be precisely adapted
to your treatment by individually selecting additional parameters
(impulse length and shape, frequency, bursts, biphasic application, and much more).
Two independent channels with individual intensity settings allow you to be completely flexible. You can treat two different
sensitive areas simultaneously, two patients with different currents or even one current and at the same time ultrasound or
simultaneous therapy. The divided display offers a comprehen-
For ultrasound therapy, you have your choice of two ergonomic
transducers (2.5 cm2 und 5 cm2), which are designed for the application of 1 and 3 MHz. The biocompatible and extremely durable titanium surface offers the highest possible safety and reliability as far as energy output is concerned. The transducers are
watertight and therefore also suitable for subaqueous treatment.
You can choose between continuous or pulsed energy output
(4 duty cycles [1:10, 1:5, 1:3, 2:5]). The visual and optional acoustic coupling controls ensure efficient treatment. If desired the
therapy time can run independent from the coupling controls.
PAGE 6
CURRENTS
» YOU WILL FIND MORE INFORMATION ABOUT THE CURRENT MODES ON PAGE 42
Medium-frequency
Low-frequency
Diagnostics
Diadynamic currents optional with galvanic base of 5%.
All low-frequency currents except for G, GMC, DF, MF, CP
and LP can also be used in biphasic application.
Faradic excitability test
Medium-frequency test (Lange)
Accommodation quotient
Rheobase/chronaxy
I/T diagnostics
I/T curve (graphic representation, can be saved)
ALTERNATING AND SIMULTANEOUS STIMULATION
By coupling both channels, doctors can treat muscle spasticity
(Hufschmidt or Jantsch) as well as alternating and simultaneous
muscle training.
CAN BE COMBINED WITH
PHYSIOVAC-Expert for combined vacuum application with vacuum electrodes or simultaneous therapy with ultrasound and
vacuum electrodes
TPS
Our innovative and user-friendly ultrasound dose program
» YOU WILL FIND MORE INFORMATION ON PAGE 41
Simultaneous therapy
STANDARD ACCESSORIES
1 Accessory tray
2 Elastic velcro straps 10 x 125 cm
2 Elastic velcro straps 6 x 80 cm
1 Mains cable
1 Manual release key
1 Operating instruction
1 Patient lead (4 connectors)
4 Plate electrodes EF 50
1 Short introduction to electrotherapy
1 Short introduction to ultrasound therapy
1 Ultrasound gel 1 l
1Ultrasound transducer
1/3 MHz 5 cm2 or 2.5 cm2
4 Viscose covers EF 50
» FOR ADDITIONAL ACCESSORIES SEE PAGE 40 OR VISIT WWW.PHYSIOMED.DE
TECHNICAL DATA
Protection class
Power connection
Mains frequency Current consumption Power consumption 1, Typ BF
230 V ±10 % or 115 V ±10 %
50–60 Hz
0.4 A (at 230 V) or 0.8 A (at 115 V)
86 VA
Power output, stimulation current, max.
Power output, ultrasound, max.
Effective surface Ultrasound frequency Mean power density 75 mA at 500 Ohm, G = 25 mA at 500 Ohm
2.5 cm² transducer 1 MHz 3 MHz 3 W/cm² 1 W/cm² 5 cm² transducer
1 MHz 3 MHz
3 W/cm² 1 W/cm²
Dimensions (W x H x D)
394 x 133 x 348 mm
Weight 5.5 kg
PAGE 7
THERAPY ICON
THERAPY FORM
Combination therapy
IONOSON-IF-Expert
Fast therapy start: direct, through program memory or indication index · Simultaneous therapy · Watertight and
biocompatible titanium transducers · TPS · 1 and 3 MHz in one ultrasound transducer · Two-channel electrotherapy unit with G, HV and TENS currents as well as all modern medium-frequency currents · Alternating and
simultaneous stimulation
DEVICE DESCRIPTION
The IONOSON-IF-Expert combination therapy unit is modelled
after the IONOSON-Expert. The IONOSON-IF-Expert is considered the “light version” and, in addition to ultrasound, also offers
two-channel electrotherapy in all the medium-frequency currents as well as for the low-frequency G, HV and TENS currents
in one unit.
The configuration of various currents can be precisely adapted
to your treatment by individually selecting additional parameters
(impulse length and shape, frequency, bursts, biphasic application, and much more).
Two independent channels with individual intensity settings allows you to be completely flexible. You can treat two different
sensitive areas simultaneously, two patients with different currents or even one current and at the same time ultrasound or
simultaneous therapy. The divided display offers a comprehen-
PAGE 8
sive overview of the therapy parameters that are currently in use
including both therapy timers. The manual release key functions
on the one hand as a therapy cut-off key (emergency shut-off
switch) for the patient and also enables the use of intentional
exercises.
For ultrasound therapy, you have your choice of two ergonomic
transducers (2.5 cm2 und 5 cm2), which are designed for the application of 1 and 3 MHz. The biocompatible and extremely durable
titanium surface offers the highest possible safety and reliability
as far as energy output is concerned. The transducers are watertight and therefore also suitable for subaqueous treatment.
You can choose between continuous or pulsed energy output (4
duty cycles [1:10, 1:5, 1:3, 2:5]). The visual and optional acoustic
coupling controls ensure efficient treatment. If desired the therapy time can run independent from the coupling controls.
CURRENTS
» YOU WILL FIND MORE INFORMATION ABOUT THE CURRENT MODES ON PAGE 42
Medium-frequency
Low-frequency
HV and TENS can also be used in biphasic
­application.
CAN BE COMBINED WITH
PHYSIOVAC-Expert for combined vacuum application with vacuum
electrodes or simultaneous therapy with ultrasound and vacuum
electrodes
TPS
Our innovative and user-friendly ultrasound dose program
» YOU WILL FIND MORE INFORMATION ON PAGE 41
STANDARD ACCESSORIES
1 Accessory tray
2 Elastic velcro straps 10 x 125 cm
2 Elastic velcro straps 6 x 80 cm
1 Mains cable
1 Manual release key
1 Operating instruction
1 Patient lead (4 connectors)
4 Plate electrodes EF 50
1 Short introduction to electrotherapy
1 Short introduction to ultrasound therapy
1 Ultrasound gel 1 l
1 Ultrasound transducer 1/3 MHz 5 cm2 or 2.5 cm2
4 Viscose covers EF 50
» FOR ADDITIONAL ACCESSORIES SEE PAGE 40 OR VISIT
WWW.PHYSIOMED.DE
IONOSON-IF-Expert combination therapy unit and PHYSIOVAC-Expert vacuum
application unit on an Expert trolley
TECHNICAL DATA
Protection class
Power connection
Mains frequency Current consumption Power consumption 1, Typ BF
230 V ±10 % or 115 V ±10 %
50–60 Hz
0.4 A (at 230 V) or 0.8 A (at 115 V)
86 VA
Power output, stimulation current, max.
Power output, ultrasound, max.
Effective surface Ultrasound frequency Mean power density 75 mA at 500 Ohm, G = 25 mA at 500 Ohm
2.5 cm² transducer 1 MHz 3 MHz 3 W/cm² 1 W/cm² 5 cm² transducer
1 MHz 3 MHz
3 W/cm² 1 W/cm²
Dimensions (W x H x D)
394 x 133 x 348 mm
Weight 5.5 kg
PAGE 9
THERAPY ICON
Electrotherapy
Electrotherapy is an important element of physical therapy. Current stimulation will treat the tissue
via electrodes (plate electrodes, adhesive electrodes, vacuum electrodes, or special electrodes such
as punctiform or pad electrodes) on the selected areas. Depending on the current mode and the
selection of parameters (i. e. impulse form, impulse duration, pause time, frequency, intensity) the
stimulation current can have significant effects in the following areas of treatment:
» Pain reduction
» Stimulation of blood circulation and trophic enhancement
» Nerve stimulation, for example the training of innervations and treatment of paralysis
» Muscle stimulation to build up/maintain muscles
» Muscular relaxation
» Iontophoresis
The following classifications of the different currents of electrotherapy can be made according to
their generation and specific method of treating the tissue:
» Medium-frequency current
This is an alternating current, which comes from a superposition of a basic frequency (2–9.5
KHz) and a modulation frequency (0-250 Hz). This superposition already takes place within the
equipment with the AMF current (amplitude modulated medium frequency current) as well
as with the medium-frequency currents for muscle stimulation (MT and KOTS). The previously
modulated current can therefore be applied via only two electrodes on the patient. With classic
interference current IF, however, the superposition delivers both frequencies when it reaches
the tissue of the patient. For this reason, in this case it is essential to always apply four electrodes for treatment. The high therapeutic effectiveness of the medium-frequency current is
gained through minimal skin irritation with broad penetration and has better acceptance for the
patients.
» An impulse current with frequencies under 1000 Hz is classified as a low-frequency current. The
total range of application is covered by the different low-frequency currents DF, MF, CP, LP (diadynamic currents) UR (ultrastimulation current), HV (high voltage current), FaS (faradic current), TENS
(mono- or biphasic rectangular impulse), MENS (variable microcurrent), IG 30 and IG 50 (impulse
galvanisation), FM (frequency-modulated current), STOCH (stochastic current), HVS (high voltage
stimulation) and T/R (exponential current). In contrast to the medium-frequency current, the lowfrequency current can also be used for the treatment of peripheral paralysis.
» The galvanic current (G) is a direct current that ensures that a constant energy current flows
through the tissue. The galvanic current is primarily used for the stimulation of blood flow and
pain reduction as well as iontophoresis (diffusion of medicaments into the tissue with the help of
the current).
For more detailed information, please read our comprehensive brochure “Short introduction to
electrotherapy”, which contains lots of practical examples.
PAGE 10
THERAPY ICON
THERAPY FORM
Electrotherapy
PHYSIOMED-Expert
Fast therapy start: direct, through program memory or indication index · Optional simultaneous therapy
Two-channel electrotherapy unit with all modern low-frequency and medium-frequency currents · Alternating and
simultaneous stimulation · Diagnostics
DEVICE DESCRIPTION
The PHYSIOMED-Expert two-channel electrotherapy unit offers
all the advantages of modern electrotherapy and diagnostics in
one unit.
The PHYSIOMED-Expert features all of the relevant low-frequency
and medium-frequency currents, which can be precisely adapted
to your treatment by individually selecting additional parameters
(impulse length and shape, frequency, bursts, biphasic application, and much more).
Two independent channels with individual intensity settings allow
you to be completely flexible. You can treat two different sensitive areas simultaneously, two patients with different currents or
even do a simultaneous treatment (optional). The divided display
offers a comprehensive overview of the therapy parameters that
are currently in use including both therapy timers. The manual
release key functions on the one hand as a therapy cut-off key
(emergency shut-off switch) for the patient and also enables the
use of intentional exercises.
TECHNICAL DATA (PHYSIOMED-Expert and PHYSIOMED-Expert PhysioView)
Protection class
Power connection
Mains frequency Current consumption
Power consumption PAGE 12
1, Typ BF
230 V ±10 % or 115 V ±10 %
50–60 Hz
0.3 A (at 230 V) or 0.6 A (at 115 V)
68 VA
Power output, stimulation current, max.
Dimensions (W x H x D)
Weight
75 mA at 500 Ohm, G = 25 mA at 500 Ohm
345 x 133 x 348 mm
5.1 kg
CURRENTS
» YOU WILL FIND MORE INFORMATION ABOUT THE CURRENT MODES ON PAGE 42
Medium-frequency
Low-frequency
Diagnostics
Diadynamic currents optional with galvanic base of 5%.
All low-frequency currents except for G, GMC, DF, MF, CP
and LP can also be used in biphasic application.
Faradic excitability test
Medium-frequency test (Lange)
Accommodation quotient
Rheobase/chronaxy
I/T diagnostics
I/T curve (graphic representation, can be saved)
STANDARD ACCESSORIES
CAN BE COMBINED WITH
1 Accessory tray
2 Elastic velcro straps 10 x 125 cm
2 Elastic velcro straps 6 x 80 cm
1 Mains cable
1 Manual release key
1 Operating instruction
1 Patient lead (4 connectors)
4 Plate electrodes EF 50
1 Short introduction to electrotherapy
4 Viscose covers EF 50
· PHYSIOSON-Expert for simultaneous therapy
· P HYSIOVAC-Expert for combined vacuum application
with vacuum electrodes
» FOR ADDITIONAL ACCESSORIES SEE PAGE 40 OR
VISIT WWW.PHYSIOMED.DE
Facial nerve paresis treatment with punctiform electrode
PHYSIOMED-Expert PhysioView
DEVICE DESCRIPTION
The PHYSIOMED-Expert PhysioView two-channel electrotherapy
unit offers all the advantages of modern electrotherapy and diagnostics in one unit. The unit is identical to the PHYSIOMEDExpert, but it includes a module for display, graphic evaluation,
management and printing of diagnostic parameters (I/T curves)
on the PC. This makes it possible to efficiently document the
therapy progress on the patient‘s medical record.
Additionally included in delivery volume
PhysioView software on CD-ROM
ChipDrive card reader
5x PhysioCard
Screenshot PhysioView
PAGE 13
THERAPY ICON
THERAPY FORM
Electrotherapy
PHYSIOMED-IF-Expert
Fast therapy start: direct, through program memory or indication index · Optional simultaneous therapy · Twochannel electrotherapy unit with G, HV and TENS currents as well as all modern medium-frequency currents
Alternating and simultaneous stimulation
DEVICE DESCRIPTION
The PHYSIOMED-IF-Expert electrotherapy unit is modelled after
the PHYSIOMED-Expert. The PHYSIOMED-IF-Expert is considered
the “light version” and offers two-channel electrotherapy in all
the medium-frequency currents as well as for the low-frequency
G, HV and TENS currents in one unit.
The configuration of various currents can be precisely adapted
to your treatment by individually selecting additional parameters
(impulse length and shape, frequency, bursts, biphasic application, and much more).
PAGE 14
Two independent channels with individual intensity settings allows you to be completely flexible. You can treat two different
sensitive areas simultaneously, two patients with different currents or even do a simultaneous treatment (optional). The divided
display offers a comprehensive overview of the therapy parameters that are currently in use including both therapy timers. The
manual release key functions on the one hand as a therapy cutoff key (emergency shut-off switch) for the patient and also enables the use of intentional exercises.
CURRENTS
» YOU WILL FIND MORE INFORMATION ABOUT THE CURRENT MODES ON PAGE 42
Medium-frequency
Low-frequency
HV and TENS can also be used in biphasic
application.
CAN BE COMBINED WITH
· PHYSIOSON-Expert for simultaneous therapy
· P HYSIOVAC-Expert for combined vacuum application
with vacuum electrodes
PHYSIOSON-Expert ultrasound therapy unit, PHYSIOMED-IF-Expert electrotherapy unit and
PHYSIOVAC-Expert vacuum application unit on an Expert trolley
STANDARD ACCESSORIES
1 Accessory tray
2 Elastic velcro straps 10 x 125 cm
2 Elastic velcro straps 6 x 80 cm
1 Mains cable
1 Manual release key
1 Operating instruction
1 Patient lead (4 connectors)
4 Plate electrodes EF 50
1 Short introduction to electrotherapy
4 Viscose covers EF 50
» FOR ADDITIONAL ACCESSORIES SEE PAGE 40 OR VISIT WWW.PHYSIOMED.DE
TECHNICAL DATA
Protection class
Power connection Mains frequency Current consumption Power consumption 1, Typ BF
230 V ±10 % or 115 V ±10 %
50–60 Hz
0.3 A (at 230 V) or 0.6 A (at 115 V)
68 VA
Power output, stimulation current, max. 75 mA at 500 Ohm, G = 25 mA at 500 Ohm
Dimensions (W x H x D)
345 x 133 x 348 mm
Weight 5.1 kg
PAGE 15
THERAPY ICON
Ultrasound therapy
Ultrasound therapy, along with electrotherapy, is one of the popular treatment forms of physical
therapy. Therapeutic ultrasound is used, with the frequency 1 MHz or 3 MHz, as continuous output
or pulsed output in different duty cycles. Ultrasound therapy is classified as mechanical thermal
therapy due to its complex effects.
Depending on therapy parameters (therapy frequency, output type, dose, therapy duration and
mode), the emphasis is on a thermal effect that results from ultrasound therapy (thermal growth
and reflecting from barriers to the tissue, for example, bones or joints) or a micromassage in the
treated tissue segments. The effects of the ultrasound therapy can be summarised as follows:
» Hyperemisation
» Acceleration of metabolic function (microcirculation, diffusion processes)
» Increasing the tensibility of connective tissue structures (collagen fibres)
» Alleviation of pain
» Muscular deionisation and spasm resolution
» Acceleration of the healing process
» Stimulation of fracture healing
Since ultrasound is reflected by air, you should use a coupling agent (ultrasound gel) or connect
under water (subaqueous) for the optimum conduction of the ultrasonic waves from the transducer
to the tissue.
For more detailed information, please read our comprehensive brochure “Short introduction to
ultrasound therapy”, which contains lots of practical examples.
PAGE 16
THERAPY ICON
THERAPY FORM
Ultrasound therapy
PHYSIOSON-Expert
Fast therapy start: direct, through program memory or indication index · Watertight and biocompatible titanium
transducers · TPS · 1 and 3 MHz in one ultrasound transducer · Continuous or pulsed energy output (4 duty cycles)
DEVICE DESCRIPTION
The exclusive ultrasound therapy unit with 1 and 3 MHz in one
transducer.
Both transducers (2.5 cm2 and 5 cm2) are designed for the application of 1 as well as 3 MHz of ultrasound. The ergonomic
transducers with a biocompatible and extremely durable titanium
surface offer the highest possible safety and reliability as far as
energy output is concerned. They are watertight and therefore
also suitable for subaqueous treatment.
PAGE 18
You can choose between continuous or pulsed energy output
(4 duty cycles [1:10, 1:5, 1:3, 2:5]). The visual and optional acoustic coupling controls ensure efficient treatment. If desired the
therapy time also can run independent from the coupling controls.
STANDARD ACCESSORIES
1 Accessory tray
4 Fixing rings
1 Mains cable
1 Operating instruction
1 Short introduction to ultrasound therapy
1 Ultrasound gel 1l
1 Ultrasound transducer 1/3 MHz 5 cm2 or 2.5 cm2
» YOU WILL FIND A COMPLETE OVERVIEW OF OUR ENTIRE
RANGE OF ACCESSORIES AT WWW.PHYSIOMED.DE
Transducer 2.5 cm2
Transducer 5 cm2
High-quality ultrasound gel
(250 ml, 1 or 5 l)
CAN BE COMBINED WITH
PHYSIOMED-Expert for simultaneous therapy
TPS
Our innovative and user-friendly ultrasound dose program
» YOU WILL FIND MORE INFORMATION ON PAGE 41
Paravertebral treatment with ultrasound
PHYSIOSON-Expert ultrasound therapy unit on an Expert trolley
TECHNICAL DATA
Protection class
Power connection Mains frequency Current consumption Power consumption 1, Typ BF
230 V ±10 % or 115 V ±10 %
50–60 Hz
0.3 A (at 230 V) or 0.6 A (at 115 V)
66 VA
Power output, ultrasound, max.
Effective surface Ultrasound frequency Mean power density 2.5 cm² transducer 1 MHz
3 MHz 3 W/cm² 1 W/cm² 5 cm² transducer
1 MHz 3 MHz
3 W/cm² 1 W/cm²
Dimensions (W x H x D)
394 x 133 x 271 mm
Weight
3.9 kg
PAGE 19
THERAPY ICON
Vacuum application
Vacuum application devices make it possible for you to apply stimulation currents via vacuum electrodes. The vacuum electrodes are gently affixed to the patient‘s skin with the help of adjustable
underpressure. This method is especially suited for affixing electrodes to the buttocks, since there
is no need for expensive fixation aids.
The suction action and the associated blood flow stimulation result in improved conduction qualities for the currents. With smooth adjustments, pulsing waves of suction allow the therapy to
stimulate even more.
Thanks to special plungers (Luran suctionwave cups), vacuum application units are also suited for
manual suction wave massage, which can also be performed on its own without being combined
with a electrotherapy unit unit.
PAGE 20
THERAPY ICON
THERAPY FORM
Vacuum application
PHYSIOVAC-Expert
Fast therapy start · Infinitely variable pulsation · Continuously adjustable vacuum output · Self-adjusting vacuum
pump ensures constant vacuum · Low-noise mode of operation · Automatic pump switch-off (with acoustic and
visual alarm)
DEVICE DESCRIPTION
The PHYSIOVAC-Expert microprocessor-controlled vacuum
application unit enables easy and comfortable application
of vacuum electrodes, especially on areas of the body that
are difficult to reach. The systematically arranged operating elements and the LED display of the vacuum output
ensure easy operation. The pulsation to stimulate the therapy is infinitely variable.
The self-adjusting vacuum pump features low-noise operation and ensures delivery of constant underpressure. The
PAGE 22
water separator has a level indicator and, if needed, automatically shuts off the PHYSIOVAC-Expert.
When combined with an electrotherapy unit, they automatically provide an application of electrotherapy through
suction electrodes.
In conjunction with special suctionwave cups, the PHYSIOVACExpert is also suitable for suctionwave massage.
STANDARD ACCESSORIES
1 Bypath hose double
1 Connection cable (electrotherapy/vacuum)
1 Operating instruction
1 Power connection lead
4 Vacustop vacuum electrodes 6 cm
4 Vacuum hoses
8 Viscose sponges 6 cm
The standard accessories include four
self-closing Vacustop electrodes. Thanks
to their soft shape, these high-quality vacuum electrodes adapt well to the curves
of the body and are available in three sizes
(3, 6 and 9 cm in diameter).
PRACTICAL EXAMPLES FROM OUR WIDE RANGE OF ADDITIONAL ACCESSORIES
Luran suctionwave cups (set) in four different sizes
(2, 3, 4 und 6 cm in diameter) for suctionwave therapy
Tetravac electrode for application of classic interferential
current in small areas
» YOU WILL FIND A COMPLETE OVERVIEW OF OUR ENTIRE RANGE OF ACCESSORIES AT WWW.PHYSIOMED.DE
CAN BE COMBINED WITH
· IONOSON-Expert, IONOSON-IF-Expert
· P HYSIOMED-Expert, PHYSIOMED-IF-Expert,
PHYSIOMED-Expert PhysioView
TECHNICAL DATA
Protection class
Power connection Mains frequency
Current consumption
Power consumption 1, Typ BF
230 V ±10 % or 115 V ±10 %
50–60 Hz
0.1A (at 230 V) or 0.2A (at 115 V)
23 VA
Vacuum Pulsation Dimensions (W x H x D)
Weight 0–0,6 bar
0–30 pulsations/min, infinitely variable
345 x 130 x 420 mm
4.4 kg
PAGE 23
THERAPY ICON
Laser therapy
Laser therapy is used in various therapy fields. In contrast to hard lasers used in surgery (30 W and
higher), laser therapists work with the athermal, therapeutic, low level laser (less than 500 mW).
As for physical therapy, the infrared diode laser is now the common means of treatment. This laser
excels over other types of lasers in penetration depth, bio-stimulative effect and ease of handling.
The assignment of laser therapy to light therapy is based on its various complex photobiological
effects. These effects can be summarised as follows:
» Enhanced cellular energy balance
» Antiphlogistic effect
» Antiedematous effect
» Microcirculatory effect
» Tissue reparative effect
» Analgetic effect
You can choose between two forms of application according to the indication. An ultra-precise
laser pen is used to treat tender points, trigger points, paraspinal points, etc. if laser application on
a very small area (less than 1 cm²) is required. The laser pen has also become the treatment method
of choice for soft application, i.e. laser puncture, which, like needle acupuncture, makes use of the
interrelation between skin and inner organs. For the treatment of larger areas of skin in cases like
traumas, joint inflammations or dermatologic indications, we recommend using the laser shower,
which can be moved over/along the treatment area, if necessary. The laser comb is especially wellsuited to treat regions with body hair, such as the scalp.
For more detailed information please read our comprehensive brochure “Short introduction to laser
therapy”, which contains lots of practical examples.
PAGE 24
THERAPY ICON
THERAPY FORM
Laser therapy
LAS-Expert
Fast therapy start: direct, through program memory or indication index · Wavelength of 785 nm – best value for
penetration depth and biostimulation · Automatic calculation of treatment parameters
DEVICE DESCRIPTION
The LAS-Expert laser unit ensures effective laser therapy with a
laser shower, laser pen and comb.
The LAS-Expert laser features an infrared diode laser with a
wavelength of 785 nm, which is scientifically proven to offer the
best values in penetration depth and biostimulation efficiency.
PAGE 26
In order to ensure a safe and effective treatment, the LAS-Expert
has a software that automatically calculates and displays the
treatment parameters after the desired energy density and treatment surface have been entered.
STANDARD ACCESSORIES
1 Accessory tray
2 Laser protection glasses
1 Mains cable
1 Operating instruction
1 Short introduction to laser therapy
APPLICATORS
(ALL OF THE APPLICATORS FEATURE ADDITIONAL KEYS FOR SETTING PARAMETERS)
Laser shower with 14 laser diodes for application on larger
surfaces with continuous output, multi-frequency and alpha
frequency (e. g., in trauma, arthropathy, large muscular hypertony and dermatology).
Easily adjustable supporting arm for treatment with the laser
shower or laser comb, can be attached to all PHYSIOMED trolleys
Laser comb with 14 laser diodes for application on larger surfaces with continuous output, multi-frequency and alpha frequency (e.g., for trichologic applications such as hair and scalp
disorders).
Scalp treatment with the laser comb
Laser pen for key point treatment and laser puncture (including
acupuncture search function with automatic start/stop function)
with continuous output, multi-frequency and NOGIER frequencies.
An optional optical waveguide is available as an autoclavable attachment for the laser pen for treatments in the fields of dentistry
and ENT.
YOU WILL FIND A COMPLETE OVERVIEW OF OUR ENTIRE RANGE OF ACCESSORIES AT WWW.PHYSIOMED.DE
TECHNICAL DATA
Protection class
Laser class
Laser type
Wavelength
Power connection Mains frequency 1, Typ BF
3B
Infrared semiconductor laser
785 nm
230 V ± 10% or 115 V ± 10%
50–60 Hz
Current consumption
Power consumption
0.15 A (at 230 V) or 0.3 A (at 115 V)
35 VA
Power output
Laser shower/comb, max. 700 mW (14 x 50 mW)
Laser pen, max.
60 mW
Dimensions (W x H x D)
345 x 133 x 271 mm
Weight
4.1 kg
PAGE 27
THERAPY ICON
Microwave therapy
Therapy with microwaves is classified as high frequency therapy. The one thing the varying frequencies used in high frequency therapy have in common is the fact that warmth is created in the
tissue under their influence. Microwaves are applied using the radiation field method, which applies beams of electromagnetic waves to the tissue depending on the usage of emitters of varying
shapes and sizes. The energy from these waves is directly absorbed in the tissue and makes it warm.
The penetration of the microwaves is inferior compared to shortwaves. Microwave therapy is the
preferred application if you want local heating of the muscles or connective tissue structures, such
as ligaments, sinews, capsules, etc.
PAGE 28
THERAPY ICON
THERAPY FORM
Microwave therapy
PHYSIOTHERM-M
Fast therapy start: direct, through program memory or indication index · Continuous or pulsed energy output
Automatic output limitation · Versatile use thanks to different applicators (optional)
DEVICE DESCRIPTION
The modern PHYSIOTHERM-M microwave therapy unit enables
continuous and pulsed energy output for thermal and athermal applications and features automatic output limitation. The extremely
well-shielded, high-frequency connection cable provides troublefree operation. The smooth running castors with latches ensure
good mobility and secure positioning of the PHYSIOTHERM-M.
The easily adjustable supporting arms ensure quick and exact
emitter placement. The high-quality and precisely manufactured
connectors make it easy to change the emitter.
PAGE 30
STANDARD ACCESSORIES
1 HF connection cable (microwave)
1 Mains cable
1 Operating instruction
1 Safety eyewear (microwave)
1 Synclinal emitter
» YOU WILL FIND A COMPLETE OVERVIEW OF OUR ENTIRE RANGE OF ACCESSORIES AT WWW.PHYSIOMED.DE
APPLICATORS
You have your choice of three easily interchangeable emitter sizes:
Omnidirectional emitter (diameter: 16 cm) for local disease processes
Small emitter (diameter: 6.5 cm) for small areas and ENT applications
Synclinal emitter for medium and large treatment areas
Omnidirectional emitter
Small emitter
Synclinal emitter
Knee treatment with an omnidirectional emitter
ENT application with a small emitter
TECHNICAL DATA
Protection class
Power connection Mains frequency Current consumption
Power consumption
Operating frequency 1, Typ B
230 V ± 10% or 115 V ± 10%
50 or 60 Hz
4 A (at 230 V) or 7 A (at 115 V)
700 VA
2450 MHz
Power output, max.
Continuous operation 25 W with small emitter (automatic changeover)
Continuous operation 200 W
Impulse mode
1250 W
Impulse frequency Dimensions (W x H x D)
400 x 790 x 300 mm
Weight 42 kg
1–50 Hz
PAGE 31
THERAPY ICON
Shortwave therapy
The application of shortwave therapy generates warmth in tissue for which electric and magnetic
fields are used. Shortwaves are applied either using the condensor field method or the coil field
method.
With the condenser field method the treated body part is placed between two condenser plates
(shell electrodes or soft rubber electrodes). A periodic charge exchange process occurs in the treated tissue under the influence of high frequency electrical alternating fields, which results in uniform
heating through of all levels of the treated tissue segments.
The coil field method uses a coil in the form of a vortex current electrode (monode) or diplode. The
high frequency current flows through the coil, which creates a variable magnetic field in its environment. The magnetic field causes a predominant warming in tissue with good conductive structure,
such as connective tissue and muscles.
In the impulse mode during the shortwave therapy, the focus is on the athermal effect with trophic
enhancement and reflective influences on the vascular system. The local thermal effect dominates
in continuous operation, causing improved cell metabolism, reduced viscosity of bodily fluids, higher tensibility of collagen fibres, circulation stimulation and manipulation of the nervous system.
Shortwave therapy is therefore used predominantly in the fields of orthopaedics, traumatology,
rheumatology as well as in ENT, urology, gynaecology and internal medicine for:
» Treatment of chronic inflammations
» Pain reduction
» Spasm reduction and muscular relaxation
PAGE 32
THERAPY ICON
THERAPY FORM
Shortwave therapy
PHYSIOTHERM-S
Fast therapy start: direct, through program memory or indication index · Matching function · Capacitor field and
coil field method (optional through additional accessories) · Continuous or pulsed power output
DEVICE DESCRIPTION
The PHYSIOTHERM-S high-end shortwave therapy unit enables
continuous and pulsed energy output for thermal and athermal applications. You can choose between the capacitor field
method for uniform heating of all the tissue layers as well as
the coil field method (optional) for selective treatment of tissue
with good conductive structures, such as connective tissue and
muscles. In addition to the graphic display of the effective power
output, the ingenious automatic matching (dynamic matching)
feature ensures the steady development of heat and prevents
overdosage by reducing the power if there is a problem. The extremely well-shielded, high-frequency connection cables provide
trouble-free operation.
The easily adjustable supporting arms ensure quick and exact electrode placement. The smooth running castors with latches ensure
good mobility and secure positioning of the PHYSIOTHERM-S.
PAGE 34
STANDARD ACCESSORIES
2 Cable holder
2 Electrode supporting arms
2 HF connection cables (shortwave)
1 Mains cable
1 Operating instruction
2 Plate electrodes 16.5 cm
PRACTICAL EXAMPLES FROM OUR WIDE RANGE OF ADDITIONAL ACCESSORIES
The plate electrodes are available in three sizes (8, 12 and 16.5 cm in diameter)
Shoulder treatment with a diplode
Rubber capacitor electrodes for treatment using capacitor technology
(18 x 12 cm or 25 x 14.5 cm)
Diplode for shortwave therapy with coil field method
Direct-axis component of magnetomotive force with plate
and rubber capacitor electrodes
Monode (special eddy current electrode) for shortwave therapy with coil field method
» YOU WILL FIND A COMPLETE OVERVIEW OF OUR ENTIRE RANGE OF ACCESSORIES AT
WWW.PHYSIOMED.DE
Ankle joint treatment with a monode
TECHNICAL DATA
Protection class
Power connection Mains frequency Current consumption
Power consumption
Operating frequency 1, Typ BF
230 V ± 10% or 115 V ± 10%
50–60 Hz
6 A (at 230 V) or 12 A (at 115 V)
1400 VA
27,12 MHz
Power output, max.
Continuous operation 400 W
Impulse mode
1000 W
Impulse frequency Impulse duration
10–300 Hz
200–600 μs
Dimensions (W x H x D)
420 x 970 x 410 mm
Weight
60 kg
PAGE 35
THERAPY ICON
Cryotherapy
Cryotherapy is based on surface cooling and uses low temperatures to reduce tissue temperature.
Cryotherapy incorporates the use of a continuously cooled stream of air with a constant temperature range, which results in a range of thermoregulatory effects that are desirable for various indications, including acute and chronic pain as well as rheumatism. Here are some of the physiological
effects of cryotherapy:
» Influence on sensory nerves
» Reduction in nerve conduction
» Immediate vasoconstrictive effect
PAGE 36
THERAPY ICON
THERAPY FORM
Cryotherapy
FRIGOSTREAM
Very short cooling phase · Adjustable air current · Cold air up to –32 °C · Flexible, double-walled tube (1.70 m long)
DEVICE DESCRIPTION
The compact FRIGOSTREAM cryotherapy unit offers optimised
performance in a very small space. It generates cold air with an
adjustable current of air and thus enables the targeted cooling of
areas of the body and offers known advantages over CO2 and ice
packs. If used correctly there is no danger of damaging the skin.
FRIGOSTREAM works with an energy source that costs nothing
– air – and is therefore always ready for immediate use and has
no resource supply problems. Like an air conditioning system,
the indoor air is cooled down and blown through a treatment
tube, without direct contact to the skin, at temperatures of up to
–32 °C. A number of optional attachments and a supporting arm
are available to ensure an application that is optimally adapted to
the indication.
PAGE 38
STANDARD ACCESSORIES
1 Tube
1 Slotted nozzle
A number of optional attachments and a supporting arm are
available to ensure an application that is optimally adapted to the
indication.
Bracket
Adapter for nozzle attachments
Nozzle attachment 5 mm
Nozzle attachment 10 mm
Nozzle attachment 15 mm
Pain therapy with cooled air
THERMAL LASER APPLICATION
The FRIGOSTREAM is also available with a thinner tube in connection with thermal laser treatments. This version has more air
capacity in order to be able to keep the cooling capacity of –32°C
constant.
Tube laser version
» YOU WILL FIND A COMPLETE OVERVIEW OF OUR ENTIRE RANGE OF ACCESSORIES AT WWW.PHYSIOMED.DE
TECHNICAL DATA
Protection class
Power connection Mains frequency Current consumption
Power consumption 1, Typ B
230 V ± 10% or 110 V ± 10%
50–60 Hz
6.5 A (at 230 V ) or 13 A (at 110 V )
1800 VA
Cooling capacity
Air capacity
Air capacity laser version
Dimensions (W x H x D)
Weight up to –32 °C
350–1500 l/min.
420–1800 l/min.
300 x 930 x 400 mm
53 kg
PAGE 39
ACCESSORIES
Electrotherapy
Additional accessories for
electrotherapy
ADHESIVE ELECTRODES
PHYSIOPADS
PLATE ELECTRODES
Reusable, extremely conductive adhesive electrodes in four different sizes
Plate electrodes in 5 sizes (EF 10, 4 x 3 cm; EF 50, 8 x 6 cm; EF 100,
12 x 8 cm; EF 200, 17 x 11 cm; EF 400, 24 x 15 cm)
CONNECTING CABLE
VISCOSE COVERS
Connecting cable for adhesive electrodes PHYSIOPADS
Viscose covers in 5 sizes (EF 10, 5 x 5.5 cm; EF 50, 11 x 9 cm; EF 100,
14 x 12 cm; EF 200, 20 x 15 cm; EF 400, 28 x 19 cm)
ELECTRODE TEST PEN
DOUBLE-/SINGLE PAD FOUR-FIELD AND
DOUBLE-PAD TWO-FIELD ELECTRODE
Electrode test pen to easily test the conductivity of plate electrodes
Small double pad four-field electrode, small single pad four-field
electrode, and double-pad two-field electrode
(special electrodes for the application of a classic interferential current)
PUNCTIFORM ELECTRODES
TRANSPORTATION BAG
Punctiform electrodes (four attachments) for differentiated nerve
and muscle stimulation and electrodiagnostics
Practical transportation bag offers optimum protection for the
unit during mobile use and transportation
(Suitable for all devices except PHYSIOTHERM-M, -S AND FRIGOSTREAM)
GLOVE ELECTRODES
ELASTIC VELCRO STRAPS
Glove electrodes for electrokinesis
Elastic velcro straps in 2 sizes (10 x 125 cm and 6 x 80 cm)
BOW ELECTRODE
IONTOPHORESIS FOIL
Bow electrode (special bipolar electrode, handheld)
Iontophoresis foil (special foil)
BERGONY MASK
RECTAL / VAGINAL PROBES
Bergony mask for electrotherapy on the face
Rectal and vaginal probes for nerve and muscle stimulation
» YOU WILL FIND A COMPLETE OVERVIEW OF OUR ENTIRE RANGE OF ACCESSORIES AT WWW.PHYSIOMED.DE
Ask us about our attractive graduated pricing of adhesive electrodes and viscose covers!
PAGE 40
INFORMATION
TPS / Simultaneous therapy
Additional information
TPS
SIMULTANEOUS THERAPY
The acronym TPS is a compilation of the Spanish words “Tiempo”
(time), “Potencia” (output) and “Superficie” (surface). According
to Spanish electrotherapy expert Prof. J. M. Rodríguez Martin, it
stands for a more exact dosage strategy in ultrasound therapy.
In addition to the delivered dose in W/cm2, the treatment surface
and time are also considered in order to deliver a precisely defined amount of energy to the tissue in J/cm2. All of our ExpertLine ultrasound therapy units now feature the innovative and
user-friendly ultrasound dose program TPS.
The transducer acts as the electrical stimulation cathode and a
plate or vacuum electrode acts as the anode in simultaneous
therapy using electrotherapy and ultrasound (with a cumulative
therapy effect). Simultaneous therapy is available using the combination units as well as by combining any electrotherapy unit
with the PHYSIOSON-Expert ultrasound therapy unit.
Simultaneous therapy is used in particular in combination therapy
units. The current selections in connection with the ultrasound
parameters ensure in singular a wide variety of treatment combinations.
TPS Screenshot
Simultaneous therapy
Trolleys
The special Expert-design trolleys are extremely stable, and the smooth running castors with latches ensure good mobility. The Expert trolleys are also available with a spacious drawer and/or
customised rack for the PHYSIOVAC-Expert vacuum application unit.
The Universal trolley with its three shelves and a spacious drawer provides lots of room for your equipment and all the additional accessories.
PAGE 41
INFORMATION
Electrotherapy: Medium-frequency / Low-frequency
Currents of electrotherapy
Medium-frequency currents
Classic interferential current
Basic frequency: 2–9.5 kHz; Modulation frequency: 0–250 Hz
4 pre-programmed frequency bands and adjustable
Vector function
Medium-frequency muscle stimulation
Basic frequency: 2–9.5 kHz
Modulation frequency: 0–125 Hz; Contraction 1–60 s, pause 1–60 s
Two-channel MT for alternating or simultaneous stimulation
Bipolar interferential current
Basic frequency: 2–9.5 kHz
Modulation frequency: 0–250 Hz
5 pre-programmed frequency bands and adjustable
Two-channel AMF for alternating or simultaneous stimulation
Russian stimulation
Basic frequency: 2–9.5 kHz; T = 2, 4, 6, 8, 10 ms, and automatic
Modulations: Sinus, triangular, rectangular
Modulation frequency: 0-125 Hz; Contraction 1–60 s, pause 1–60 s
Two-channel KOTS for alternating or simultaneous stimulation
Low-frequency currents All low-frequency currents (except for G, GMC, DF, MF, CP and LP) can also be used in biphasic
application. Diadynamic currents optional with galvanic base of 5 %.
Galvanisation (iontophoresis) and mediumfrequency, open-circuited direct current
Galvanic microcurrent
Ultrastimulation current 143 Hz
Frequency-modulated current 7–14 Hz
High voltage current 1–200 Hz
T = 80–400 µs
2 frequency bands; Bursts 1–10 Hz
Stochastic current 10–100 Hz
Diadynamic current 100 Hz
Transcutaneous electr. nerve stimulation 1–200 Hz
T = 80–400 µs
2 frequency bands; Bursts 1–10 Hz
High voltage stimulation 1–200 Hz
Contraction 1– 60 s, pause 1–60 s
4 ramps; Two-channel HVS for alternating or
simultaneous stimulation
Manual impulse triggering
Diadynamic current 50 Hz
Variable microcurrent
Diadynamic current 100 Hz/50Hz
Faradic current
Contraction 1–60 s, pause 1–60 s; 4 ramps
Manual impulse triggering
Impulse galvanisation 12 Hz
Diadynamic current 100 Hz/50 Hz
Impulse galvanisation 8 Hz
PAGE 42
Exponential current T = 0.1 ms – 1 s; R = 1 ms – 7 s
Manual single impulse triggering; Triangular impulse,
rectangular impulse and 6 other impulse shapes
11/2007. Not responsible for errors. Subject to change without notice.
ADDRESS
PHONE
EMAIL
PHYSIOMED ELEKTROMEDIZIN AG
Hutweide 10
91220 Schnaittach/Laipersdorf
Germany
+49(0)9126/2587-0
[email protected]
FAX
WEB
+49(0)9126/2587-25
www.physiomed.de
GB