walsall Explosion Protected Electrical Equipment
Transcription
walsall Explosion Protected Electrical Equipment
walsall Walsall Ltd Cornwallis Road, West Bromwich, West Midlands, B70 7DX. United Kingdom Telephone: +44 (0) 121 500 6161 Fax: +44 (0) 121 500 6300 Email: [email protected] www.walsall-ltd.com Walsall Asia Pacific Pte Ltd 10 Upper Aljunied Link, York International Industrial Building #02-05, Singapore 367904 Telephone: (65) 6858-5259 Fax : (65) 6858-6560 Email : [email protected] www.walsall-ltd.com Please refer to website for a comprehensive list of worldwide partners ATEX GOST The information contained in this catalogue has been carefully compiled. Walsall Ltd does not accept any responsibility for loss caused by any error contained herein. Cover photo courtesy of Royal Dutch Shell Edition 2006/1 Design by Nexus Creative Ltd +44 (0)1905 821919 www.nexuscl.com Explosion Protected Electrical Equipment Your Local Distributor Terminal Boxes Local Control Stations and Panels Power Switching Motor Control Distribution Boards Lighting Plugs and Sockets Emergency Shutdown and Signalling Equipment Installation Accessories An Introduction to Walsall CONTENTS Walsall Conduits started designing and manufacturing electrical equipment for hazardous areas in the 1930’s. In those days the company concentrated on equipment for underground applications, particularly coal mining. The products were designated flameproof for what is now known as Group 1 applications. Walsall has been involved in many worldwide projects over the past few years, a sample of which are shown below- As petro-chemical and pharmaceutical operations were developed through the later half of the 20th Century Walsall designed and manufactured products for above ground applications particularly in the fields of switch gear and motor control gear. Shell Bintulu - Far East - EEx d fluorescent lighting In 2000 the company was renamed Walsall Ltd and began a new phase of development by widening the product range significantly. Heathrow Airport - UK - EEx d wellglasses & panels From inception to the present day Walsall products have become specified in all parts of the world. The name Walsall has become synonymous with hazardous area electrical equipment and its products can be seen working everywhere where explosive hazards exist. Channel Tunnel - UK - EEx e,ia junction boxes Walsall has always been known for the robustness of its products. It is well known that Walsall products were built to last and the company is still called out to help with installations performing after more than 50 years. This philosophy of building the strongest and safest equipment runs right through the company’s operations. PFD-Tengichevrol - Russia - EEx e,ia junction boxes & Eexd panels All products are approved by the British Notified Bodies Baseefa and SIRA , and the manufacturing facility is ATEX/UL/GOST/ISO9001:2000 approved. The company is still very much a designer and manufacturer of its own products. Many of the manufacturing processes are vertically integrated within the Walsall plant. South Pars - Middle East - EEx d fluorescent lighting This gives the company complete control of quality at each stage of manufacturing and the facility to offer excellent levels of service. Customising products and systems is now a speciality of the operation. Petrofac - Kashagan - Russia - EEx e,ia junction boxes Shell Sarawak - Malaysia - EEx e,ia junction boxes Shell Bonga - Nigeria - EEx e,ia junction boxes BP Grangemouth - UK - EEx d control stations Esso Fawley - UK - EEx de fluorescent lighting Maersk Air - Europe - EEx de control stations (local) Hong Kong Airport - Far East - EEx d fluorescent lighting Bangkok Airport - FarEast - EEx d fluorescent lighting PDO – Compressor upgrades - Oman - EEx de breakglass units & jb's Buhasa upgrade – AbuDhabi (GASCO) - Middle East - EEx e,ia junction box Hazardous Areas and the Specification of Electrical Equipment Page 3 - 6 PFD-Sahakalin pipeline - Russia - EEx e,ia junction boxes NIOEC-Compressor upgrade - Middle East - EEx d control stations & panels Part 1 Terminal Boxes Page 8 - 80 IOEC-Pumping stations - Middle East - EEx d control stations & panels PCC-Methanol Plant - Middle East - EEx e,ia junction boxes South Pars - Middle East - EEx d control stations & panels Styrene Monomer Plant - Iran - EEx e,ia junction boxes Part 2 Control in GRP, Stainless Steel and Aluminium Enclosures Page 82 - 128 Part 3 Control in Cast Iron, Cast Stainless Steel and Cast Aluminium Enclosures Page 130 - 150 Part 4 Power Switching Page 152 - 170 Part 5 Motor Control Page 172 - 182 Part 6 Distribution Boards Page 184 - 186 Part 7 Lighting Page 188 - 208 Part 8 Plugs and Sockets Page 210 - 214 Part 9 Emergency Shutdown and Signalling Equipment Page 216 - 226 Part 10 Installation Accessories Page 228 - 236 MOL Danube Refinery - Hungary - EEx e,ia junction boxes Ourhoud - Socket Panels - Algeria - EEx d/EExde Socket Panels Bechtel - Karachaganak - Russia - EEx e,ia junction boxes NPCC - Abu Dhabi - Middle East - EEx d Control Panels + Isolators Conoco Phillips/Fluor Daniel - Bohai Phase II - US - EEx e HV terminal box ABB - Offshore Khuff Gas Development - Middle East - EEx d Control Panels A selection of specifiers, end-users and installers of Walsall products includeShell, BP, Chevron, Agip, Maersk Oil & Gas, Elf, NIGC, IOEC, NIOC, Pfizer, Glaxo, Petrobras, Woodside, ADNOC, GASCO, ZADCO, Saudi Aramco, Texaco, Aker-Kvaerner, Brown & Root, Costain, Conoco Philips , ABB, KBR, Bechtel, PFD, Snamprogetti, Cegelec, Technip, Mustang Engineering, Petronas, Marathon Oil & Gas, Transco, BNFL, London Underground, Virgin, Ikea, British Sugar…… ATEX GOST 2003/383 1 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 2 A Guide to the Selection of Electrical Equipment for Installation in Hazardous Areas A Guide to the Selection of Electrical Equipment for Installation in Hazardous Areas The information below is given as a guide to enable the users of this catalogue to select the correct equipment for their application. It should not be used to define the nature of hazardous areas, this is a task for experienced professionals in the field of hazardous area definition. Nor should it be used as replacement for the very detailed standards which cover the installation of electrical equipment in hazardous areas. THE CLASSIFICATION OF HAZARDOUS AREAS Gases, Vapours, Mists and Dusts. What conditions are required for an explosion? Explosive atmospheres are caused by a mixture of gases, vapours, mists dusts and air. If the explosive atmosphere is caused by gases, vapours and mists the hazardous area is coded G. If the explosive atmosphere is caused by dusts the hazardous area is coded D. There are three elements required in order to create a hazardous area. Explosion Groups HAZARDOUS ATMOSPHERES 1. 2 3. Air. An flammable medium for example gases, vapours, mists and dusts. A source of ignition of sufficient energy and /or a rise in temperature. GAS OR DUST AIR In the first instance equipment is divided into two groups depending on its location above or below ground. What is an explosive atmosphere? An explosive atmosphere is created when air and an flammable medium mix such that a rise in temperature or an electrical spark produces an explosion. Explosion protected electrical equipment is classified in terms of the ignition temperature, the ignition capability and flame transmission capacity of the explosive atmosphere in which it is designed to operate. SPARK Group I Electrical equipment for use below ground in areas susceptible to firedamp. Group II Electrical equipment for all other areas. What is a potentially explosive atmosphere? An atmosphere is defined as potentially explosive when in its normal state it is not explosive but there exists the possibility that in abnormal circumstances it will become explosive. For example in the case of a gas leak or the vapourisation of a fluid leak. Ignition Energy An explosive atmosphere needs a minimum energy for ignition. The energy produced by arcs and sparks are many times greater than this minimum. Self Ignition Temperature An explosive atmosphere can self ignite if the local temperature rises above the so-called self ignition temperature. This temperature is different for different flammable mediums. Self ignition temperatures for a range of commonly found flammable gasses and dust are given in Table 1 and 2. Table 1 Typical self ignition temperatures for Gases Gas Butane Ethyl acetate Acetylene Ethylene Carbon disulphide Hydrogen Acetone Ammonia Ethyle nitrate Benzne Industrial methane Carbon monoxide Table 2 Typical self ignition temperatures for Dusts Dust Cellulose Cocoa Flour Lead Lignite Polyacrylonitrate Soya meal Zinc 3 Temp. +˚C 287 425 300 450 90 500 465 650 90 498 535 605 Temp. +˚C Cloud Layer 490 430 500 200 490 430 460 240 380 225 540 400 540 340 570 440 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Table 3 Examples of gases divided into gas groups I Methane IIB IIC IIA Town gas Hydrogen Acetone Benzol Ethylene Acetylene Acetic acid Carbon disulphide Methanol Petrol Diesel Aviation fuel Carbon monoxide Heating oils Acetaldehyde Group II equipment is further divided into three sub groups depending on the ignition and flame transmission characteristics of the explosive hazard. These sub-groups are designated IIA, IIB and IIC. Zones - the probability of an explosive atmosphere occurring. Zone 0 defines an area in which an explosive atmosphere caused by a mixture of air and gases, vapours and mists is present continuously for long periods or very frequently. Zone 1 defines areas in which an explosive atmosphere caused by a mixture air and gases, vapours and mists is expected to occur occasionally. Zone 2 defines areas in which an explosive atmosphere caused by a mixture of air and gases, vapours and mists is unlikely and if it should occur it will be for a short time and then only rarely. Zone 20 defines an area in which an explosive atmosphere caused by a cloud of combustible dust and air is present continuously for long periods or very frequently. Zone 21 defines areas in which an explosive atmosphere caused by a cloud of combustible dust and air is expected to occur occasionally. Table 4 Definition of zones Zones Type of Hazard Probability of Hazard 0 G 20 D Continuous 1 G 21 D Infrequent 2 G 22 D Occasional Zone 22 defines areas in which an explosive atmosphere caused by a cloud of combustible dust and air is unlikely and if it should occur it will be for a short time and then only rarely. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 4 A Guide to the Selection of Electrical Equipment for Installation in Hazardous Areas A Guide to the Selection of Electrical Equipment for Installation in Hazardous Areas Table 5 Temperature Classes Ignition Temperature The ignition temperature is the lowest temperature on the surface at which an explosive atmosphere will ignite. Gases and dusts have been divided into temperature classes according to their ignition temperatures so that electrical equipment can be further sub-divided into six temperature classes T1 to T6. The temperature classes are shown in Table 5. Note. The maximum operating surface temperature of a piece of electrical equipment must always be below the ignition temperature of the explosive mixture, see Table 6 opposite. Temperature Class T1 T2 T3 T4 T5 T6 Ingress Protection Maximum Surface Temperature ˚C 450 300 200 135 100 85 Because hazardous area electrical equipment is very often used in hostile atmospheric environments the standards call for minimum levels of protection against water and dust. For example the minimum level set is IP54 however in the case of dust hazards the minimum level ingress protection is set at IP64. The range of IP levels are shown in Table 8 opposite Table 8 IP Rating IPXY X 0 1 2 3 4 5 6 Protected From None Solids <50mm diam Solids <12.5mm diam Solids <2.5mm diam Solids <1.0mm diam Dust protected Dust tight Y 0 1 2 3 4 5 6 Protected From None Water dripping vertically Water dripping at 15 deg Spray water at 60 deg Splash water from any direction Jet water from any direction Powerful water jets from any direction 7 Water when submerged for limited time 8 Water when submerged for indeterminate time Table 6 Self ignition Temperatures and Temperature Classes Self Ignition Temperature ˚C 85˚<T˚<100˚C 100˚<T˚<135˚C 135˚<T˚<200˚C 200˚<T˚<300˚C 300˚<T˚<450˚C 450˚<T˚ T6 (85˚) Temperature class of the equipment T4 T3 T2 T1 T5 (100˚) (135˚) (200˚) (300˚) (450˚) EXPLOSION READING THE LABEL The ATEX standards call for the manufacturers of hazardous area electrical equipment to label their products with the following information. A typical label for a flood light is shown for reference in Table 9. 1. Name of manufacturer 2. Product type code 3. Address of manufacturer 4. Year of manufacture 5. Marking in accordance with directive 94/9/EC II 3 GD – group II location, category 3 equipment, for gas and dust hazards Table 9 Typical product label 3 1 6 6. Equipment Categories. Electrical equipment for hazardous areas is designed to comply with different fault levels depending on the Zone in which the equipment is to be installed. These fault levels are designated as Categories 1, 2 and 3. Their relationship with the zones, the potential for an explosive atmosphere and the type of explosive atmosphere is shown in Table 7 opposite. 5 Table 7 Relationship between zones and equipment categories Zones Type of Hazard Categories 0 G 20 D 1 1 G 21 D 2 2 G 22 D 3 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Marking in accordance with European standards EEx nR II T – built and tested to European standards, type of protection, explosion group, temperature class 7. CE marking together with notified body registration number 8. Notified testing body and reference number 9. Serial number 10. Technical data 11. Ingress protection 5 11 7 8 2 10 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 4 9 6 PART 1.0 TERMINAL BOXES Comprehensive ranges of EEx e, EEx i and EEx d terminal boxes in fabricated stainless steel, mild steel and aluminium, glass reinforced polyester, cast aluminium, cast iron and cast stainless steel. 1.1 SL Range Page 9 Small EEx e and EEx i approved terminal boxes and enclosures without gland plates in fabricated stainless and mild steel 1.2 FXL Range Page 17 Medium to large EEx e and EEx i approved terminal boxes and enclosures with the option of up to 4 gland plates and a detachable hinged cover, fabricated in stainless and mild steel 1.3 XL Range Page 31 Medium to large EEx e and EEx i approved terminal boxes and enclosures with the option of up to 4 gland plates and a detachable hinged cover, fabricated in stainless and mild steel 1.4 HVB Range Page 45 High voltage terminal boxes rated at 3.3 and 6.6kV 1.5 AL Range Page 47 Small EEx e and EEx i approved terminal boxes and enclosures without gland plates in fabricated aluminium 1.6 GVU Junction Box Page 55 EEx e Junction Box in Glass Reinforced Polyester with Pillar or MK Terminals 1.7 GL Range Page 57 Small, medium and large EEx e and EEx i approved terminal boxes and enclosures in glass reinforced polyester 1.8 E Range Page 73 Small EEx d approved terminal boxes in cast iron 1.9 ASMT Range Page 77 Medium and large EEx d approved terminal boxes and enclosures in cast aluminium, cast iron and cast stainless steel 7 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 8 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type SL1 - 110mm x 110mm x 65mm PART 1.1 SL RANGE EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Small EEx e and EEx i approved terminal boxes and enclosures without gland plates, fabricated from electro polished stainless steel and powder coated mild steel. The terminal boxes have ingress protection to IP66/67. Type SL1 – 110mm x 110mm x 65mm Page 10 Type SL2 – 120mm x 120mm x 80mm Page 11 Type SL3 – 150mm x 120mm x 80mm Page 12 Type SL4 – 150mm x 150mm x 90mm Page 13 Type SL5 – 190mm x 150mm x 90mm Page 14 Type SL6 – 190mm x 190mm x 100mm Page 15 CUSTOMISING As a vertically integrated manufacturer Walsall can customise the SL range at each stage of the manufacturing process to meet individual customer requirements. Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6,T5,T4,T3. EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5 (+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66/67 to EN60529:1992 Maximum 9 Watts. Except for dust applications where the maximum is 4.5 Watts ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting Internal Mounting 110mm x 110mm x 65mm 1.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 1.2Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance holes DIN rail or mounting plate to suit All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rail Horizontal Rail WDU 2.5 1x14 1x14 WDU 4 1x11 1x11 A GUIDE TO ENTRY CAPACITY WDU 6 1x8 1x8 Gland Size mm Side A + B Side C + D WDU 10 1x6 1x6 20 3 3 25 2 2 32 0 0 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded ORDERING INFORMATION Material Stainless Steel Mild Steel Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powder coated 10mm internal/external stainless steel earth stud 9 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com EEx e Terminal Box SLS11 SLM11 EEx e U Component Approved Enclosure SLS12 SLM12 EEx ia Terminal Box SLS13 SLM13 CES6 SL1MP SSET tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 10 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type SL2 - 120mm x 120mm x 80mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type SL3 - 150mm x 120mm x 80mm Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Weight empty Cover fixing Gasket Earthing Entries External Mounting Internal Mounting Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5 (+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66/67 to EN60529:1992 Maximum 9 watts. Except for dust applications where the maximum is 4.5 Watts Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5 (+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66/67 to EN60529:1992 Maximum 9 Watts. Except for dust applications where the maximum is 4.5 Watts ENCLOSURE SPECIFICATION 120mm x 120mm x 80mm 1.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 1.4Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance holes DIN rail or mounting plate to suit Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting Internal Mounting 150mm x 120mm x 80mm 1.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032. 1.6Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance holes DIN rail or mounting plate to suit All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rail Horizontal Rail WDU 2.5 1x16 1x16 WDU 4 1x13 1x13 All Dimensions in mm A GUIDE TO ENTRY CAPACITY WDU 6 1x9 1x9 Gland Size mm Side A + B Side C + D WDU 10 1x7 1x7 20 6 6 A GUIDE TO PHYSICAL TERMINAL CAPACITY 25 3 3 32 2 2 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Verticle Rail Horizontal Rail WDU 2.5 1x22 1x16 WDU 4 1x18 1x13 A GUIDE TO ENTRY CAPACITY WDU 6 1x13 1x9 Gland Size mm Side A + B Side C + D WDU 10 1x10 1x7 20 8 6 25 4 3 32 2 2 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded ORDERING INFORMATION ORDERING INFORMATION Material Stainless Steel Mild Steel EEx e Terminal Box SLS21 SLM21 Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powder coated 10mm internal/external stainless steel earth stud 11 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Finish EEx e II and EE x ia IIC EEx e U Component Approved Enclosure SLS22 SLM22 EEx ia Terminal Box SLS23 SLM23 CES6 SL2MP SSET tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Stainless Steel Mild Steel Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powder coated 10mm internal/external stainless steel earth stud EEx e Terminal Box SLS31 SLM31 EEx e U Component Approved Enclosure SLS32 SLM32 EEx ia Terminal Box SLS33 SLM33 CES6 SL3MP SSET tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 12 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type SL4 - 150mm x 150mm x 90mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type SL5 - 190mm x 150mm x 90mm Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Weight empty Cover fixing Gasket Earthing Entries External Mounting Internal Mounting Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5 (+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66/67 to EN60529:1992 Maximum 11 Watts. Except for dust applications where the maximum is 5.5 Watts Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5 (+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66/67 to EN60529:1992 Maximum 11 Watts. Except for dust applications where the maximum is 5.5 Watts ENCLOSURE SPECIFICATION 150mm x 150mm x 90mm 1.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 1.9Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance holes DIN rail or mounting plate to suit Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting Internal Mounting 190mm x 150mm x 90mm 1.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 2Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance holes DIN rail or mounting plate to suit All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rail Horizontal Rail WDU 2.5 1x22 1x22 WDU 4 1x18 1x18 All Dimensions in mm A GUIDE TO ENTRY CAPACITY WDU 6 1x13 1x13 Gland Size mm Side A + B Side C + D WDU 10 1x10 1x10 20 8 8 A GUIDE TO PHYSICAL TERMINAL CAPACITY 25 5 5 32 3 3 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Verticle Rail Horizontal Rail WDU 2.5 1x30 1x22 WDU 4 1x24 1x18 A GUIDE TO ENTRY CAPACITY WDU 6 1x18 1x13 Gland Size mm Side A + B Side C + D WDU 10 1x14 1x10 20 8 10 25 5 7 32 3 3 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded ORDERING INFORMATION ORDERING INFORMATION Material Stainless Steel Mild Steel EEx e Terminal Box SLS41 SLM41 Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powder coated 10mm internal/external stainless steel earth stud 13 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Finish EEx e II and EE x ia IIC EEx e U Component Approved Enclosure SLS42 SLM42 EEx ia Terminal Box SLS43 SLM43 CES6 SL4MP SSET tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Stainless Steel Mild Steel Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powder coated 10mm internal/external stainless steel earth stud EEx e Terminal Box SLS51 SLM51 EEx e U Component Approved Enclosure SLS52 SLM52 EEx ia Terminal Box SLS53 SLM53 CES6 SL5MP SSET tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 14 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type SL6 - 190mm x 190mm x 100mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5 (+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66/67 to EN60529:1992 Maximum 13 watts. Except for dust applications where the maximum is 6.5 Watts ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting Internal Mounting 190mm x 190mm x 100mm 1.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 3Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance holes DIN rail or mounting plate to suit All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rail Horizontal Rail WDU 2.5 1x30 1x30 WDU 4 1x24 1x24 A GUIDE TO ENTRY CAPACITY WDU 6 1x18 1x18 Gland Size mm Side A + B Side C + D WDU 10 1x14 1x14 20 14 14 25 8 8 32 4 4 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded ORDERING INFORMATION Material Stainless Steel Mild Steel EEx e Terminal Box SLS61 SLM61 Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powder coated 10mm internal/external stainless steel earth stud 15 EEx e U Component Approved Enclosure SLS62 SLM62 EEx ia Terminal Box SLS63 SLM63 CES6 SL6MP SSET tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 16 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type FXL1 - 229mm x 152mm x 130mm PART 1.2 FXL RANGE EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 HAZARDOUS AREA SPECIFICATION Medium to large EEx e and EEx i approved terminal boxes with an outward return cover sealing flange. There is an option of up to 4 gland plates. The cover is detachable and hinged. The enclosure is fabricated from electroplated stainless steel or powder coated mild steel. The terminal boxes have Ingress Protection to IP66, 67. Type FXL1 – 229mm x 152mm x 130mm Page 18 Type FXL2 – 260mm x 260mm x 150mm or 200mm Page 19 Type FXL3 – 306mm x 306mm x 150mm or 200mm Page 20 Type FXL4 – 380mm x 260mm x 150mm or 200mm Page 21 Type FXL5 – 458mm x 382mm x 150mm or 200mm Page 22 Type FXL6 – 480mm x 480mm x 150mm or 200mm Page 23 Type FXL7 – 500mm x 350mm x 150mm or 200mm Page 24 Type FXL8 – 620mm x 450mm x 150mm or 200mm Page 25 Type FXL9 – 762mm x 508mm x 150mm or 200mm Page 26 Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Type FXL10 – 914mm x 610mm x 200mm or 300mm Page 27 II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 to EN60529:1992 Maximum 15 Watts. Except for dust applications where the maximum is 7.5 Watts ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Weight empty Cover fixing Gasket Earthing Security Entries Mounting 229mm x 152mm x 130mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 3.4Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes Return flange sealing All Dimensions in mm Type FXL11 – 1177mm x 777mm x 210mm or 300mm Page 28 Type FXLX – 2000mm max x 1250mm max x 600mm max A GUIDE TO PHYSICAL TERMINAL CAPACITY Page 29 Verticle Rail Horizontal Rail CUSTOMISING As a vertically integrated manufacturer Walsall can customise the FXL range at each stage of the manufacturing process to meet individual customer requirements WDU 2.5 1x35 1x20 WDU 4 1x29 1x16 Gland Size mm Side A + B Side C + D WDU 10 1x16 1x9 20 6 6 25 3 3 32 2 2 * More entries are available if direct entry is used ORDERING INFORMATION Gland Plate options Material Number 0 0 1 1 2 2 3 3 4 4 Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 6 1x21 1x12 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel 17 ATEX/GOST/UL Location B B AB AB BCD BCD ABCD ABCD CES6 XL1MP BP2 SSET EEx e Terminal Box FXLS110 FXLM110 FXLS111 FXLM111 FXLS112 FXLM112 FXLS113 FXLM113 FXLS114 FXLM114 Product Codes EEx e U Component Approved FXLS120 FXLM120 FXLS121 FXLM121 FXLS122 FXLM122 FXLS123 FXLM123 FXLS124 FXLM124 Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com EEx ia Terminal Box FXLS130 FXLM130 FXLS131 FXLM131 FXLS132 FXLM132 FXLS133 FXLM133 FXLS134 FXLM134 GPS6 XL1RC XL1DW 18 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type FXL2 - 260mm x 260mm x 150mm or 200mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type FXL3 - 306mm x 306mm x 150mm or 200mm ATEX/GOST/UL EEx e II and EE x ia IIC HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Weight empty Cover fixing Gasket Earthing Security Entries Mounting II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 to EN60529:1992 Maximum 15 Watts. Except for dust applications where the maximum is 7.5 Watts Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rails Horizontal Rails WDU 4 2x34 2x34 WDU 6 2x25 2x25 Dimensions Material box Material gland plate Finish Weight empty Cover fixing Gasket Earthing Security Entries Mounting Return flange sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 2x20 2x20 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 17 11 FXL2 25 11 6 32 5 2 20 28 16 306mm x 306mm x 150mm or 200mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 6.5Kg and 7.0Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes A GUIDE TO TERMINAL CAPACITY (WDU type) FXL2D 25 15 9 32 11 8 ORDERING INFORMATION Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Verticle Rails Horizontal Rails WDU 2.5 2x51 2x51 WDU 4 2x42 2x42 WDU 6 2x31 2x31 Return flange sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 2x24 2x24 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 21 15 FXL3 25 12 9 32 6 4 20 32 23 FXL3D 25 18 12 32 12 9 * More entries are available if direct entry is used ORDERING INFORMATION Gland Plate options Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud 19 ATEX/GOST/UL II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 to EN60529:1992 Maximum 21 Watts. Except for dust applications where the maximum is 10.5 Watts * More entries are available if direct entry is used Material Group II Cat 1,2 ENCLOSURE SPECIFICATION 260mm x 260mm x 150mm or 200mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 5.5Kg and 6Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes WDU 2.5 2x42 2x42 T3,T4,T5,T6 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Zones 0,1,2,21,22 Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box FXLS230 FXLS210D FXLS220D FXLS230D FXLS220 FXLS210 FXLM230 FXLM210D FXLM220D FXLM230D FXLM220 FXLM210 FXLS231 FXLS211D FXLS221D FXLS231D FXLS221 FXLS211 FXLM231 FXLM211D FXLM221D FXLM231D FXLM221 FXLM211 FXLS232 FXLS212D FXLS222D FXLS232D FXLS222 FXLS212 FXLM222 FXLM232 FXLM212D FXLM222D FXLM232D FXLM212 FXLS213 FXLS223 FXLS233 FXLS213D FXLS223D FXLS233D FXLM213 FXLM223 FXLM233 FXLM213D FXLM223D FXLM233D FXLS214 FXLS224 FXLS234 FXLS214D FXLS224D FXLS234D FXLM214 FXLM224 FXLM234 FXLM214D FXLM224D FXLM234D CES6 XL2MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet GPS6 XL2RC XL2DW tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Gland Plate options Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box FXLS330 FXLS310D FXLS320D FXLS330D FXLS320 FXLS310 FXLM330 FXLM310D FXLM320D FXLM330D FXLM320 FXLM310 FXLS331 FXLS311D FXLS321D FXLS331D FXLS321 FXLS311 FXLM331 FXLM311D FXLM321D FXLM331D FXLM321 FXLM311 FXLS332 FXLS312D FXLS322D FXLS332D FXLS322 FXLS312 FXLM322 FXLM332 FXLM312D FXLM322D FXLM332D FXLM312 FXLS313 FXLS323 FXLS333 FXLS313D FXLS323D FXLS333D FXLM313 FXLM323 FXLM333 FXLM313D FXLM323D FXLM333D FXLS314 FXLS324 FXLS334 FXLS314D FXLS324D FXLS334D FXLM314 FXLM324 FXLM334 FXLM314D FXLM324D FXLM334D CES6 XL3MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com GPS6 XL3RC XL3DW 20 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type FXL4 -380mm x 260mm x 150mm or 200mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type FXL5 - 458mm x 382mm x 150mm or 200mm ATEX/GOST/UL EEx e II and EE x ia IIC HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Weight empty Cover fixing Gasket Earthing Security Entries Mounting II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 to EN60529:1992 Maximum 21 Watts. Except for dust applications where the maximum is 10.5 Watts Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rails Horizontal Rails WDU 4 2x49 2x35 WDU 6 2x36 2x26 Weight empty Cover fixing Gasket Earthing Security Entries Mounting Return flange sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 2x29 2x20 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 17 18 FXL4 25 10 12 32 5 6 20 27 28 458mm x 382mm x 150mm or 200mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 10Kg and 11Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes A GUIDE TO PHYSICAL TERMINAL CAPACITY FXL4D 25 15 15 32 11 11 ORDERING INFORMATION Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Verticle Rails Horizontal Rails WDU 2.5 3x81 3x66 WDU 4 3x67 3x55 WDU 6 3x50 3x40 Return flange sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 3x39 3x33 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 27 27 FXL5 25 17 17 32 9 9 20 40 40 FXL5D 25 24 24 32 17 17 * More entries are available if direct entry is used ORDERING INFORMATION GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud 21 ATEX/GOST/UL II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 to EN60529:1992 Maximum 29 Watts. Except for dust applications where the maximum is 14.5 Watts * More entries are available if direct entry is used Material Group II Cat 1,2 ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish 380mm x 260mm x 150mm or 200mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 6.5Kg and 7.0Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes WDU 2.5 2x60 2x43 T3,T4,T5,T6 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Zones 0,1,2,21,22 Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box FXLS430 FXLS410D FXLS420D FXLS430D FXLS420 FXLS410 FXLM430 FXLM410D FXLM420D FXLM430D FXLM420 FXLM410 FXLS431 FXLS411D FXLS421D FXLS431D FXLS421 FXLS411 FXLM431 FXLM411D FXLM421D FXLM431D FXLM421 FXLM411 FXLS432 FXLS412D FXLS422D FXLS432D FXLS422 FXLS412 FXLM422 FXLM432 FXLM412D FXLM422D FXLM432D FXLM412 FXLS413 FXLS423 FXLS433 FXLS413D FXLS423D FXLS433D FXLM413 FXLM423 FXLM433 FXLM413D FXLM423D FXLM433D FXLS414 FXLS424 FXLS434 FXLS414D FXLS424D FXLS434D FXLM414 FXLM424 FXLM434 FXLM414D FXLM424D FXLM434D CES6 XL4MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet GPS6 XL4RC XL4DW tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box FXLS530 FXLS510D FXLS520D FXLS530D FXLS520 FXLS510 FXLM530 FXLM510D FXLM520D FXLM530D FXLM520 FXLM510 FXLS531 FXLS511D FXLS521D FXLS531D FXLS521 FXLS511 FXLM531 FXLM511D FXLM521D FXLM531D FXLM521 FXLM511 FXLS532 FXLS512D FXLS522D FXLS532D FXLS522 FXLS512 FXLM522 FXLM532 FXLM512D FXLM522D FXLM532D FXLM512 FXLS513 FXLS523 FXLS533 FXLS513D FXLS523D FXLS533D FXLM513 FXLM523 FXLM533 FXLM513D FXLM523D FXLM533D FXLS514 FXLS524 FXLS534 FXLS514D FXLS524D FXLS534D FXLM514 FXLM524 FXLM534 FXLM514D FXLM524D FXLM534D CES6 XL5MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com GPS6 XL5RC XL5DW 22 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type FXL6 - 480mm x 480mm x 150mm or 200mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type FXL7 - 500mm x 350mm x 150mm or 200mm ATEX/GOST/UL EEx e II and EE x ia IIC HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Weight empty Cover fixing Gasket Earthing Security Entries Mounting Verticle Rails Horizontal Rails T3,T4,T5,T6 II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 to EN60529:1992 Maximum 30 Watts. Except for dust applications where the maximum is 15 Watts Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 to EN60529:1992 Maximum 21 Watts. Except for dust applications where the maximum is 10.5 Watts A GUIDE TO PHYSICAL TERMINAL CAPACITY WDU 2.5 WDU 4 WDU 6 4x86 4x71 4x53 4x86 4x71 4x53 WDU 10 4x42 4x42 Weight empty Cover fixing Gasket Earthing Security Entries Mounting Return flange sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* Enclosure Size FXL6 FXL6D Gland Size mm 20 25 32 20 25 Side A+B 36 22 11 52 33 Side C+D 29 18 9 44 27 500mm x 350mm x 150mm or 200mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 10.5Kg and 11Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes A GUIDE TO PHYSICAL TERMINAL CAPACITY 32 23 18 Verticle Rails Horizontal Rails WDU 2.5 3x90 4x60 WDU 4 3x74 4x49 WDU 6 3x55 4x36 ORDERING INFORMATION Return flange sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 3x44 4x29 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded * More entries are available if direct entry is used Enclosure Size Gland Size mm Side A+B Side C+D 20 24 24 FXL7 25 16 16 32 8 8 20 36 36 FXL7D 25 21 21 32 15 15 * More entries are available if direct entry is used ORDERING INFORMATION GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud 23 ATEX/GOST/UL ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish 480mm x 480mm x 150mm or 200mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 10.4Kg and 11Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Group II Cat 1,2 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Zones 0,1,2,21,22 Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box FXLS630 FXLS610D FXLS620D FXLS630D FXLS620 FXLS610 FXLM630 FXLM610D FXLM620D FXLM630D FXLM620 FXLM610 FXLS631 FXLS611D FXLS621D FXLS631D FXLS621 FXLS611 FXLM631 FXLM611D FXLM621D FXLM631D FXLM621 FXLM611 FXLS632 FXLS612D FXLS622D FXLS632D FXLS622 FXLS612 FXLM622 FXLM632 FXLM612D FXLM622D FXLM632D FXLM612 FXLS613 FXLS623 FXLS633 FXLS613D FXLS623D FXLS633D FXLM613 FXLM623 FXLM633 FXLM613D FXLM623D FXLM633D FXLS614 FXLS624 FXLS634 FXLS614D FXLS624D FXLS634D FXLM614 FXLM624 FXLM634 FXLM614D FXLM624D FXLM634D CES6 XL6MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet GPS6 XL6RC XL6DW tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box FXLS730 FXLS710D FXLS720D FXLS730D FXLS720 FXLS710 FXLM730 FXLM710D FXLM720D FXLM730D FXLM720 FXLM710 FXLS731 FXLS711D FXLS721D FXLS731D FXLS721 FXLS711 FXLM731 FXLM711D FXLM721D FXLM731D FXLM721 FXLM711 FXLS732 FXLS712D FXLS722D FXLS732D FXLS722 FXLS712 FXLM722 FXLM732 FXLM712D FXLM722D FXLM732D FXLM712 FXLS713 FXLS723 FXLS733 FXLS713D FXLS723D FXLS733D FXLM713 FXLM723 FXLM733 FXLM713D FXLM723D FXLM733D FXLS714 FXLS724 FXLS734 FXLS714D FXLS724D FXLS734D FXLM714 FXLM724 FXLM734 FXLM714D FXLM724D FXLM734D CES6 XL7MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com GPS6 XL7RC XL7DW 24 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type FXL8 - 620mm x 450mm x 150mm or 200mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type FXL9 - 762mm x 508mm x 150mm or 200mm ATEX/GOST/UL EEx e II and EE x ia IIC HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Weight empty Cover fixing Gasket Earthing Security Entries Mounting II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 to EN60529:1992 Maximum 41.7 Watts. Except for dust applications where the maximum is 20.5 Watts Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rails Horizontal Rails WDU 4 5x66 3x94 WDU 6 5x49 3x70 Dimensions Material box Material gland plate Finish Weight empty Cover fixing Gasket Earthing Security Entries Mounting Return flange sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 5x39 3x56 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 29 38 FXL8 25 18 24 32 9 12 20 44 56 762mm x 508mm x 150mm or 200mm 2.0mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 22Kg and 24Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes A GUIDE TO PHYSICAL TERMINAL CAPACITY FXL8D 25 27 36 32 18 24 ORDERING INFORMATION Verticle Rails Horizontal Rails WDU 2.5 4x142 6x91 WDU 4 4x118 6x76 WDU 6 4x88 6x56 Return flange sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 4x70 6x44 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 38 38 FXL9 25 24 24 32 12 12 20 56 56 FXL9D 25 36 36 32 24 24 * More entries are available if direct entry is used ORDERING INFORMATION GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud 25 ATEX/GOST/UL II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 to EN60529:1992 Maximum 41.7 Watts. Except for dust applications where the maximum is 20.5 Watts * More entries are available if direct entry is used Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Group II Cat 1,2 ENCLOSURE SPECIFICATION 620mm x 450mm x 150mm or 200mm 2.0mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 17Kg and 17.5Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes WDU 2.5 5x80 3x114 T3,T4,T5,T6 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Zones 0,1,2,21,22 Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box FXLS830 FXLS810D FXLS820D FXLS830D FXLS820 FXLS810 FXLM830 FXLM810D FXLM820D FXLM830D FXLM820 FXLM810 FXLS831 FXLS811D FXLS821D FXLS831D FXLS821 FXLS811 FXLM831 FXLM811D FXLM821D FXLM831D FXLM821 FXLM811 FXLS832 FXLS812D FXLS822D FXLS832D FXLS822 FXLS812 FXLM822 FXLM832 FXLM812D FXLM822D FXLM832D FXLM812 FXLS813 FXLS823 FXLS833 FXLS813D FXLS823D FXLS833D FXLM813 FXLM823 FXLM833 FXLM813D FXLM823D FXLM833D FXLS814 FXLS824 FXLS834 FXLS814D FXLS824D FXLS834D FXLM814 FXLM824 FXLM834 FXLM814D FXLM824D FXLM834D CES6 XL8MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet GPS6 XL8RC XL8DW tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box FXLS930 FXLS910D FXLS920D FXLS930D FXLS920 FXLS910 FXLM930 FXLM910D FXLM920D FXLM930D FXLM920 FXLM910 FXLS931 FXLS911D FXLS921D FXLS931D FXLS921 FXLS911 FXLM931 FXLM911D FXLM921D FXLM931D FXLM921 FXLM911 FXLS932 FXLS912D FXLS922D FXLS932D FXLS922 FXLS912 FXLM922 FXLM932 FXLM912D FXLM922D FXLM932D FXLM912 FXLS913 FXLS923 FXLS933 FXLS913D FXLS923D FXLS933D FXLM913 FXLM923 FXLM933 FXLM913D FXLM923D FXLM933D FXLS914 FXLS924 FXLS934 FXLS914D FXLS924D FXLS934D FXLM914 FXLM924 FXLM934 FXLM914D FXLM924D FXLM934D CES6 XL9MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com GPS6 XL9RC XL9DW 26 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type FXL10 - 914mm x 610mm x 200mm or 300mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type FXL11 - 1177mm x 777mm x 210mm or 300mm ATEX/GOST/UL EEx e II and EE x ia IIC HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Weight empty Cover fixing Gasket Earthing Security Entries Mounting II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 to EN60529:1992 Maximum 93.4 Watts. Except for dust applications where the maximum is 46 Watts Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rails Horizontal Rails WDU 4 5x143 7x93 WDU 6 5x127 7x69 Dimensions Material box Material gland plate Finish Weight empty Cover fixing Gasket Earthing Security Entries Mounting Return flange sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 5x85 7x55 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 72 72 FXL10 25 42 42 32 30 30 FXL10D 20 25 126 84 126 84 1177mm x 777mm x 210mm or 300mm 2.0mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 36Kg and 39Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes A GUIDE TO PHYSICAL TERMINAL CAPACITY 32 50 50 ORDERING INFORMATION Verticle Rails Horizontal Rails WDU 2.5 6x224 9x145 WDU 4 6x187 9x120 WDU 6 6x139 9x90 Return flange sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 6x111 9x71 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 72 72 FXL11 25 42 42 32 30 30 20 126 126 FXL11D 25 84 84 32 50 50 * More entries are available if direct entry is used ORDERING INFORMATION GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud 27 ATEX/GOST/UL II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 to EN60529:1992 Maximum 100 Watts. Except for dust applications where the maximum is 50 Watts * More entries are available if direct entry is used Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Group II Cat 1,2 ENCLOSURE SPECIFICATION 914mm x 610mm x 200mm or 300mm 2.0mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 31Kg and 34Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes WDU 2.5 5x172 7x112 T3,T4,T5,T6 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Zones 0,1,2,21,22 Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box FXLS1030 FXLS1010D FXLS1020D FXLS1030D FXLS1020 FXLS1010 FXLM1030 FXLM1010D FXLM1020D FXLM1030D FXLM1020 FXLM1010 FXLS1031 FXLS1011D FXLS1021D FXLS1031D FXLS1021 FXLS1011 FXLM1031 FXLM1011D FXLM1021D FXLM1031D FXLM1021 FXLM1011 FXLS1032 FXLS1012D FXLS1022D FXLS1032D FXLS1022 FXLS1012 FXLM1022 FXLM1032 FXLM1012D FXLM1022D FXLM1032D FXLM1012 FXLS1013 FXLS1023 FXLS1033 FXLS1013D FXLS1023D FXLS1033D FXLM1013 FXLM1023 FXLM1033 FXLM1013D FXLM1023D FXLM1033D FXLS1014 FXLS1024 FXLS1034 FXLS1014D FXLS1024D FXLS1034D FXLM1014 FXLM1024 FXLM1034 FXLM1014D FXLM1024D FXLM1034D CES6 XL10MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet GPS6 XL10RC XL10DW tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box FXLS1130 FXLS1110D FXLS1120D FXLS1130D FXLS1120 FXLS1110 FXLM1130 FXLM1110D FXLM1120D FXLM1130D FXLM1120 FXLM1110 FXLS1131 FXLS1111D FXLS1121D FXLS1131D FXLS1121 FXLS1111 FXLM1131 FXLM1111D FXLM1121D FXLM1131D FXLM1121 FXLM1111 FXLS1132 FXLS1112D FXLS1122D FXLS1132D FXLS1122 FXLS1112 FXLM1122 FXLM1132 FXLM1112D FXLM1122D FXLM1132D FXLM1112 FXLS1113 FXLS1123 FXLS1133 FXLS1113D FXLS1123D FXLS1133D FXLM1113 FXLM1123 FXLM1133 FXLM1113D FXLM1123D FXLM1133D FXLS1114 FXLS1124 FXLS1134 FXLS1114D FXLS1124D FXLS1134D FXLM1114 FXLM1124 FXLM1134 FXLM1114D FXLM1124D FXLM1134D CES6 XL11MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com GPS6 XL11RC XL11DW 28 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type FXLX - Extra Large Enclosures to 2000mm x 1250mm x 600mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 to EN60529:1992 Maximum 100 Watts. Except for dust applications where the maximum is 50 Watts ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Weight empty Cover fixing Gasket Earthing Security Entries Mounting 2000mm max x 1250mm max x 600mm max 2.0mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 36Kg and 39Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes Return flange sealing All Dimensions in mm ORDERING INFORMATION These enclosures are made to order and can be any size up to the maximum dimensions given. Specification to be agreed between the customer and Walsall sales. Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 6mm eathing stud welded to gland plate Rain canopy Document wallet 10mm internal/external stainless steel earth stud 29 CES6 XLXMP BP2 GPS6 XLXRC XLXDW SSET tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com High speed fully automatic cutting station producing stainless steel enclosures. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 30 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type XL1 - 229mm x 152mm x 130mm PART 1.3 XL RANGE EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Medium to large EEx e and EEx i approved terminal boxes with edge sealing. There is an option of up to 4 gland plates. The cover is detachable and hinged. The enclosure is fabricated from electroplated stainless steel and powder coated mild steel. The terminal boxes have Ingress Protection to IP66, 67, 68 and have been deluge tested to DT501 99. Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Type XL1 – 229mm x 152mm x130mm Page 32 Type XL2 – 260mm x 260mm x 150mm or 200mm Page 33 ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Type XL3 – 306mm x 306mm x 150mm or 200mm Page 34 Type XL4 – 380mm x 260mm x 150mm or 200mm Page 35 Type XL5 – 458mm x 382mm x 150mm or 200mm Page 36 Type XL6 – 480mm x 480mm x 150mm or200mm Page 37 Weight empty Cover fixing Type XL7 – 500mm x 350mm x 150mm or 200mm Page 38 Gasket Type XL8 – 620mm x 450mm x 150mm or 200mm Page 39 Earthing Type XL9 – 762mm x 508mm x 150mm or 200mm Page 40 Type XL10 – 914mm x 610mm x 200mm or 300mm Page 41 Type XL11 – 1177mm x 777mm x 210mm or 300mm Page 42 II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 and 68 to EN60529:1992 Deluge test DT501 99 Maximum 15 Watts. Except for dust applications where the maximum is 7.5 Watts Security Entries Mounting 229mm x 152mm x 130mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 3.4Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes Edge sealing All Dimensions in mm Type XLX – 2000mm max x 1250mm max x 600mm max Page 43 CUSTOMISING As a vertically integrated manufacturer Walsall can customise the XL range at each stage of the manufacturing process to meet individual customer requirements A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rail Horizontal Rail WDU 2.5 1x35 1x20 WDU 4 1x29 1x16 20 6 6 25 3 3 32 2 2 * More entries are available if direct entry is used ORDERING INFORMATION Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Gland Plate options Number 0 0 1 1 2 2 3 3 4 4 Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Gland Size mm Side A + B Side C + D WDU 10 1x16 1x9 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Material 31 A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 6 1x21 1x12 Location B B AB AB BCD BCD ABCD ABCD CES6 XL1MP BP2 SSET EEx e Terminal Box XLS110 XLM110 XLS111 XLM111 XLS112 XLM112 XLS113 XLM113 XLS114 XLM114 Product Codes EEx e U Component Approved XLS120 XLM120 XLS121 XLM121 XLS122 XLM122 XLS123 XLM123 XLS124 XLM124 Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com EEx ia Terminal Box XLS130 XLM130 XLS131 XLM131 XLS132 XLM132 XLS133 XLM133 XLS134 XLM134 GPS6 XL1RC XL1DW 32 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type XL2 - 260mm x 260mm x 150mm or 200mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type XL3 - 306mm x 306mm x 150mm or 200mm ATEX/GOST/UL EEx e II and EE x ia IIC HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Weight empty Cover fixing Gasket Earthing Security Entries Mounting II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 and 68 to EN60529:1992 Deluge test DT501 99 Maximum 15 Watts. Except for dust applications where the maximum is 7.5 Watts Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rails Horizontal Rails WDU 4 2x34 2x34 WDU 6 2x25 2x25 Dimensions Material box Material gland plate Finish Weight empty Cover fixing Gasket Earthing Security Entries Mounting Edge sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 2x20 2x20 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 17 11 XL2 25 11 6 32 5 2 20 28 16 306mm x 306mm x 150mm or 200mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 6.5Kg and 7.0Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes A GUIDE TO TERMINAL CAPACITY (WDU type) XL2D 25 15 9 32 11 8 ORDERING INFORMATION Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Verticle Rails Horizontal Rails WDU 2.5 2x51 2x51 WDU 4 2x42 2x42 WDU 6 2x31 2x31 Edge sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 2x24 2x24 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 21 15 XL3 25 12 9 32 6 4 20 32 23 XL3D 25 18 12 32 12 9 * More entries are available if direct entry is used ORDERING INFORMATION Gland Plate options Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud 33 ATEX/GOST/UL II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 and 68 to EN60529:1992 Deluge test DT501 99 Maximum 21 Watts. Except for dust applications where the maximum is 10.5 Watts * More entries are available if direct entry is used Material Group II Cat 1,2 ENCLOSURE SPECIFICATION 260mm x 260mm x 150mm or 200mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 5.5Kg and 6Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes WDU 2.5 2x42 2x42 T3,T4,T5,T6 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Zones 0,1,2,21,22 Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box XLS230 XLS210D XLS220D XLS230D XLS220 XLS210 XLM230 XLM210D XLM220D XLM230D XLM220 XLM210 XLS231 XLS211D XLS221D XLS231D XLS221 XLS211 XLM231 XLM211D XLM221D XLM231D XLM221 XLM211 XLS232 XLS212D XLS222D XLS232D XLS222 XLS212 XLM222 XLM232 XLM212D XLM222D XLM232D XLM212 XLS213 XLS223 XLS233 XLS213D XLS223D XLS233D XLM213 XLM223 XLM233 XLM213D XLM223D XLM233D XLS214 XLS224 XLS234 XLS214D XLS224D XLS234D XLM214 XLM224 XLM234 XLM214D XLM224D XLM234D CES6 XL2MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet GPS6 XL2RC XL2DW tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Gland Plate options Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box XLS330 XLS310D XLS320D XLS330D XLS320 XLS310 XLM330 XLM310D XLM320D XLM330D XLM320 XLM310 XLS331 XLS311D XLS321D XLS331D XLS321 XLS311 XLM331 XLM311D XLM321D XLM331D XLM321 XLM311 XLS332 XLS312D XLS322D XLS332D XLS322 XLS312 XLM322 XLM332 XLM312D XLM322D XLM332D XLM312 XLS313 XLS323 XLS333 XLS313D XLS323D XLS333D XLM313 XLM323 XLM333 XLM313D XLM323D XLM333D XLS314 XLS324 XLS334 XLS314D XLS324D XLS334D XLM314 XLM324 XLM334 XLM314D XLM324D XLM334D CES6 XL3MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com GPS6 XL3RC XL3DW 34 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type XL4 - 380mm x 260mm x 150mm or 200mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type XL5 - 458mm x 382mm x 150mm or 200mm ATEX/GOST/UL EEx e II and EE x ia IIC HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Weight empty Cover fixing Gasket Earthing Security Entries Mounting II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 and 68 to EN60529:1992 Deluge test DT501 99 Maximum 21 Watts. Except for dust applications where the maximum is 10.5 Watts Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rails Horizontal Rails WDU 4 2x49 2x35 WDU 6 2x36 2x26 Dimensions Material box Material gland plate Finish Weight empty Cover fixing Gasket Earthing Security Entries Mounting Edge sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 2x29 2x20 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 17 18 XL4 25 10 12 32 5 6 20 27 28 458mm x 382mm x 150mm or 200mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 10Kg and 11Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes A GUIDE TO PHYSICAL TERMINAL CAPACITY XL4D 25 15 15 32 11 11 ORDERING INFORMATION Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Verticle Rails Horizontal Rails WDU 2.5 3x81 3x66 WDU 4 3x67 3x55 WDU 6 3x50 3x40 Edge sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 3x39 3x33 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 27 27 XL5 25 17 17 32 9 9 20 40 40 XL5D 25 24 24 32 17 17 * More entries are available if direct entry is used ORDERING INFORMATION GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud 35 ATEX/GOST/UL II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 and 68 to EN60529:1992 Deluge test DT501 99 Maximum 29 Watts. Except for dust applications where the maximum is 14.5 Watts * More entries are available if direct entry is used Material Group II Cat 1,2 ENCLOSURE SPECIFICATION 380mm x 260mm x 150mm or 200mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 6.5Kg and 7.0Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes WDU 2.5 2x60 2x43 T3,T4,T5,T6 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Zones 0,1,2,21,22 Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box XLS430 XLS410D XLS420D XLS430D XLS420 XLS410 XLM430 XLM410D XLM420D XLM430D XLM420 XLM410 XLS431 XLS411D XLS421D XLS431D XLS421 XLS411 XLM431 XLM411D XLM421D XLM431D XLM421 XLM411 XLS432 XLS412D XLS422D XLS432D XLS422 XLS412 XLM422 XLM432 XLM412D XLM422D XLM432D XLM412 XLS413 XLS423 XLS433 XLS413D XLS423D XLS433D XLM413 XLM423 XLM433 XLM413D XLM423D XLM433D XLS414 XLS424 XLS434 XLS414D XLS424D XLS434D XLM414 XLM424 XLM434 XLM414D XLM424D XLM434D CES6 XL4MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet GPS6 XL4RC XL4DW tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box XLS530 XLS510D XLS520D XLS530D XLS520 XLS510 XLM530 XLM510D XLM520D XLM530D XLM520 XLM510 XLS531 XLS511D XLS521D XLS531D XLS521 XLS511 XLM531 XLM511D XLM521D XLM531D XLM521 XLM511 XLS532 XLS512D XLS522D XLS532D XLS522 XLS512 XLM522 XLM532 XLM512D XLM522D XLM532D XLM512 XLS513 XLS523 XLS533 XLS513D XLS523D XLS533D XLM513 XLM523 XLM533 XLM513D XLM523D XLM533D XLS514 XLS524 XLS534 XLS514D XLS524D XLS534D XLM514 XLM524 XLM534 XLM514D XLM524D XLM534D CES6 XL5MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com GPS6 XL5RC XL5DW 36 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type XL6 - 480mm x 480mm x 150mm or 200mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type XL7 - 500mm x 350mm x 150mm or 200mm ATEX/GOST/UL EEx e II and EE x ia IIC HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Weight empty Cover fixing Gasket Earthing Security Entries Mounting Verticle Rails Horizontal Rails T3,T4,T5,T6 II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 and 68 to EN60529:1992 Deluge test DT501 99 Maximum 30 Watts. Except for dust applications where the maximum is 15 Watts Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 and 68 to EN60529:1992 Deluge test DT501 99 Maximum 21 Watts. Except for dust applications where the maximum is 10.5 Watts A GUIDE TO PHYSICAL TERMINAL CAPACITY WDU 2.5 WDU 4 WDU 6 4x86 4x71 4x53 4x86 4x71 4x53 WDU 10 4x42 4x42 Dimensions Material box Material gland plate Finish Weight empty Cover fixing Gasket Earthing Security Entries Mounting Edge sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* Enclosure Size XL6 XL6D Gland Size mm 20 25 32 20 25 Side A+B 36 22 11 52 33 Side C+D 29 18 9 44 27 500mm x 350mm x 150mm or 200mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 10.5Kg and 11Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes A GUIDE TO PHYSICAL TERMINAL CAPACITY 32 23 18 Verticle Rails Horizontal Rails WDU 2.5 3x90 4x60 WDU 4 3x74 4x49 WDU 6 3x55 4x36 ORDERING INFORMATION Edge sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 3x44 4x29 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded * More entries are available if direct entry is used Enclosure Size Gland Size mm Side A+B Side C+D 20 24 24 XL7 25 16 16 32 8 8 20 36 36 XL7D 25 21 21 32 15 15 * More entries are available if direct entry is used ORDERING INFORMATION GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud 37 ATEX/GOST/UL ENCLOSURE SPECIFICATION 480mm x 480mm x 150mm or 200mm 1.5mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 10.4Kg and 11Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Group II Cat 1,2 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Zones 0,1,2,21,22 Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box XLS630 XLS610D XLS620D XLS630D XLS620 XLS610 XLM630 XLM610D XLM620D XLM630D XLM620 XLM610 XLS631 XLS611D XLS621D XLS631D XLS621 XLS611 XLM631 XLM611D XLM621D XLM631D XLM621 XLM611 XLS632 XLS612D XLS622D XLS632D XLS622 XLS612 XLM622 XLM632 XLM612D XLM622D XLM632D XLM612 XLS613 XLS623 XLS633 XLS613D XLS623D XLS633D XLM613 XLM623 XLM633 XLM613D XLM623D XLM633D XLS614 XLS624 XLS634 XLS614D XLS624D XLS634D XLM614 XLM624 XLM634 XLM614D XLM624D XLM634D CES6 XL6MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet GPS6 XL6RC XL6DW tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box XLS730 XLS710D XLS720D XLS730D XLS720 XLS710 XLM730 XLM710D XLM720D XLM730D XLM720 XLM710 XLS731 XLS711D XLS721D XLS731D XLS721 XLS711 XLM731 XLM711D XLM721D XLM731D XLM721 XLM711 XLS732 XLS712D XLS722D XLS732D XLS722 XLS712 XLM722 XLM732 XLM712D XLM722D XLM732D XLM712 XLS713 XLS723 XLS733 XLS713D XLS723D XLS733D XLM713 XLM723 XLM733 XLM713D XLM723D XLM733D XLS714 XLS724 XLS734 XLS714D XLS724D XLS734D XLM714 XLM724 XLM734 XLM714D XLM724D XLM734D CES6 XL7MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com GPS6 XL7RC XL7DW 38 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type XL8 - 620mm x 450mm x 150mm or 200mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type XL9 - 762mm x 508mm x 150mm or 200mm ATEX/GOST/UL EEx e II and EE x ia IIC HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Weight empty Cover fixing Gasket Earthing Security Entries Mounting II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 and 68 to EN60529:1992 Deluge test DT501 99 Maximum 41.7 Watts. Except for dust applications where the maximum is 20.5 Watts Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rails Horizontal Rails WDU 4 5x66 3x94 WDU 6 5x49 3x70 Dimensions Material box Material gland plate Finish Weight empty Cover fixing Gasket Earthing Security Entries Mounting Edge sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 5x39 3x56 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 29 38 XL8 25 18 24 32 9 12 20 44 56 762mm x 508mm x 150mm or 200mm 2.0mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 22Kg and 24Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes A GUIDE TO PHYSICAL TERMINAL CAPACITY XL8D 25 27 36 32 18 24 ORDERING INFORMATION Verticle Rails Horizontal Rails WDU 2.5 4x142 6x91 WDU 4 4x118 6x76 WDU 6 4x88 6x56 Edge sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 4x70 6x44 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 38 38 XL9 25 24 24 32 12 12 20 56 56 XL9D 25 36 36 32 24 24 * More entries are available if direct entry is used ORDERING INFORMATION GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud 39 ATEX/GOST/UL II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 and 68 to EN60529:1992 Deluge test DT501 99 Maximum 41.7 Watts. Except for dust applications where the maximum is 20.5 Watts * More entries are available if direct entry is used Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Group II Cat 1,2 ENCLOSURE SPECIFICATION 620mm x 450mm x 150mm or 200mm 2.0mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 17Kg and 17.5Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes WDU 2.5 5x80 3x114 T3,T4,T5,T6 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Zones 0,1,2,21,22 Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box XLS830 XLS810D XLS820D XLS830D XLS820 XLS810 XLM830 XLM810D XLM820D XLM830D XLM820 XLM810 XLS831 XLS811D XLS821D XLS831D XLS821 XLS811 XLM831 XLM811D XLM821D XLM831D XLM821 XLM811 XLS832 XLS812D XLS822D XLS832D XLS822 XLS812 XLM822 XLM832 XLM812D XLM822D XLM832D XLM812 XLS813 XLS823 XLS833 XLS813D XLS823D XLS833D XLM813 XLM823 XLM833 XLM813D XLM823D XLM833D XLS814 XLS824 XLS834 XLS814D XLS824D XLS834D XLM814 XLM824 XLM834 XLM814D XLM824D XLM834D CES6 XL8MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet GPS6 XL8RC XL8DW tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box XLS930 XLS910D XLS920D XLS930D XLS920 XLS910 XLM930 XLM910D XLM920D XLM930D XLM920 XLM910 XLS931 XLS911D XLS921D XLS931D XLS921 XLS911 XLM931 XLM911D XLM921D XLM931D XLM921 XLM911 XLS932 XLS912D XLS922D XLS932D XLS922 XLS912 XLM922 XLM932 XLM912D XLM922D XLM932D XLM912 XLS913 XLS923 XLS933 XLS913D XLS923D XLS933D XLM913 XLM923 XLM933 XLM913D XLM923D XLM933D XLS914 XLS924 XLS934 XLS914D XLS924D XLS934D XLM914 XLM924 XLM934 XLM914D XLM924D XLM934D CES6 XL9MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com GPS6 XL9RC XL9DW 40 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type XL10 - 914mm x 610mm x 200mm or 300mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type XL11 - 1177mm x 777mm x 210mm or 300mm ATEX/GOST/UL EEx e II and EE x ia IIC HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Weight empty Cover fixing Gasket Earthing Security Entries Mounting II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 and 68 to EN60529:1992 Deluge test DT501 99 Maximum 93.4 Watts. Except for dust applications where the maximum is 46 Watts Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rails Horizontal Rails WDU 4 5x143 7x93 WDU 6 5x127 7x69 Dimensions Material box Material gland plate Finish Weight empty Cover fixing Gasket Earthing Security Entries Mounting Edge sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 5x85 7x55 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 72 72 XL10 25 42 42 32 30 30 20 126 126 1177mm x 777mm x 210mm or 300mm 2.0mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 36Kg and 39Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes A GUIDE TO PHYSICAL TERMINAL CAPACITY XL10D 25 84 84 32 50 50 ORDERING INFORMATION Verticle Rails Horizontal Rails WDU 2.5 6x224 9x145 WDU 4 6x187 9x120 WDU 6 6x139 9x90 Edge sealing All Dimensions in mm A GUIDE TO ENTRY CAPACITY FOR GLAND PLATES* WDU 10 6x111 9x71 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Enclosure Size Gland Size mm Side A+B Side C+D 20 72 72 XL11 25 42 42 32 30 30 20 126 126 XL11D 25 84 84 32 50 50 * More entries are available if direct entry is used ORDERING INFORMATION GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud 41 ATEX/GOST/UL II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 and 68 to EN60529:1992 Deluge test DT501 99 Maximum 100 Watts. Except for dust applications where the maximum is 50 Watts * More entries are available if direct entry is used Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Group II Cat 1,2 ENCLOSURE SPECIFICATION 914mm x 610mm x 200mm or 300mm 2.0mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 31Kg and 34Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes WDU 2.5 5x172 7x112 T3,T4,T5,T6 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Zones 0,1,2,21,22 Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box XLS1030 XLS1010D XLS1020D XLS1030D XLS1020 XLS1010 XLM1030 XLM1010D XLM1020D XLM1030D XLM1020 XLM1010 XLS1031 XLS1011D XLS1021D XLS1031D XLS1021 XLS1011 XLM1031 XLM1011D XLM1021D XLM1031D XLM1021 XLM1011 XLS1032 XLS1012D XLS1022D XLS1032D XLS1022 XLS1012 XLM1022 XLM1032 XLM1012D XLM1022D XLM1032D XLM1012 XLS1013 XLS1023 XLS1033 XLS1013D XLS1023D XLS1033D XLM1013 XLM1023 XLM1033 XLM1013D XLM1023D XLM1033D XLS1014 XLS1024 XLS1034 XLS1014D XLS1024D XLS1034D XLM1014 XLM1024 XLM1034 XLM1014D XLM1024D XLM1034D CES6 XL10MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet GPS6 XL10RC XL10DW tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel Stainless Mild Steel GLAND PLATE OPTIONS Number Location 0 0 1 B 1 B 2 AB 2 AB 3 BCD 3 BCD 4 ABCD 4 ABCD Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 10mm internal/external stainless steel earth stud Product Code (150mm deep) Product Code (200mm deep) EEx e Terminal Box EEx e U Enclosure EEx ia Terminal Box EEx e Terminal Box EEx e U Enclosure EE ia Terminal Box XLS1130 XLS1110D XLS1120D XLS1130D XLS1120 XLS1110 XLM1130 XLM1110D XLM1120D XLM1130D XLM1120 XLM1110 XLS1131 XLS1111D XLS1121D XLS1131D XLS1121 XLS1111 XLM1131 XLM1111D XLM1121D XLM1131D XLM1121 XLM1111 XLS1132 XLS1112D XLS1122D XLS1132D XLS1122 XLS1112 XLM1122 XLM1132 XLM1112D XLM1122D XLM1132D XLM1112 XLS1113 XLS1123 XLS1133 XLS1113D XLS1123D XLS1133D XLM1113 XLM1123 XLM1133 XLM1113D XLM1123D XLM1133D XLS1114 XLS1124 XLS1134 XLS1114D XLS1124D XLS1134D XLM1114 XLM1124 XLM1134 XLM1114D XLM1124D XLM1134D CES6 XL11MP BP2 SSET Optional Extras 6mm earthing stud welded to gland plate Rain canopy Document wallet tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com GPS6 XL11RC XL11DW 42 EEx e and EEx i Terminal Boxes - Stainless and Mild Steel Type XLX - Extra Large Enclosures to 2000mm x 1250mm x 600mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66,67 and 68 to EN60529:1992 Deluge test DT501 99 Maximum 100 Watts. Except for dust applications where the maximum is 50 Watts ENCLOSURE SPECIFICATION Dimensions Material box Material gland plate Finish Weight empty Cover fixing Gasket Earthing Security Entries Mounting 2000mm max x 1250mm max x 600mm max 2.0mm 316L, (1.4404) stainless steel or mild steel 2.5mm 316L, (1.4404) stainless steel or mild steel Stainless steel – electropolished Mild steel – Powder coated RAL 7032 36Kg and 39Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes Edge sealing All Dimensions in mm ORDERING INFORMATION These enclosures are made to order and can be any size up to the maximum dimensions given. Specification to be agreed between the customer and Walsall sales. Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, mild steel powdercoated Brass padlock with 2 keys 6mm eathing stud welded to gland plate Rain canopy Document wallet 10mm internal/external stainless steel earth stud 43 CES6 XLXMP BP2 GPS6 XLXRC XLXDW SSET tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 44 High Voltage Terminal Box - Stainless Steel Enclosure Type HVB - EEx e Terminal Box with High Voltage Terminals to 6.6kV PART 1.4 HVB RANGE EEx e II Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION High Voltage Terminal Box to 6.6kV manufactured from fabricated stainless steel with electropolished finish. The terminal boxes have Ingress Protection to IP66, 67 and 68 and have been deluge tested to DT501 99. Type HVB3.3 – 977mm x 677mm x300mm Page 46 Type HVB6.6 – 1250mm x 800mm x 300mm Page 46 CUSTOMISING As a vertically integrated manufacturer Walsall can customise the HVB range at each stage of the manufacturing process to meet individual customer requirements Marking to 94/9/EC Type of Protection Temperature Class. Area Classification Certification No. Ingress Protection II 2 GD EEx e II T6 -50˚C to +55˚C Zones 1,2,21,22 Sira 00ATEX3206 IP66,67 68 to EN60529:1992 Deluge Test to DT501 99 ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover Fixing Gasket Earthing Security Mounting 977mm x 677mm x 300mm 1250mm x 800mm x 300mm 2.0mm 316L (1.4404) Stainless Steel Electro-polished 50 Kg Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta <-40˚C 10mm brass or stainless steel internal/external earth Padlockable hasp External lugs with 10mm ENTRY SPECIFICATION Entries direct into body or gland plates to customer specification All Dimensions in mm ELECTRICAL SPECIFICATION Operating Voltage Operating Current 6.6kV max 650 Amps max Three equally spaced internal bus bars are mounted on insulators rated at 10kV. The insulators are in turn installed on an epoxy glass laminate board that is fastened onto mounting rails fixed to the standard enclosure fixing points. There are six plastic cable support cleats mounted on GRP support rails for each bus bar connection point. ORDERING INFORMATION Voltage Rating 3.3 kV 6.6 kV 45 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code HVB3.3 HVB6.6 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 46 EEx e and EEx i Terminal Boxes - Aluminium Type AL1 - 110mm x 110mm x 65mm PART 1.5 AL RANGE EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Small EEx e and EEx i approved terminal boxes and enclosures without gland plates, fabricated from powder coated aluminum. The terminal boxes have ingress protection to IP66/67. Type AL1 – 110mm x 110mm x 65mm Page 48 Type AL2 – 120mm x 120mm x 80mm Page 49 Type AL3 – 150mm x 120mm x 80mm Page 50 Type AL4 – 150mm x 150mm x 90mm Page 51 Type AL5 – 190mm x 150mm x 90mm Page 52 Type AL6 – 190mm x 190mm x 100mm Page 53 Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66/67 to EN60529:1992 Maximum 9 Watts. Except for dust applications where the maximum is 4.5 Watts Ingress protection Power dissipation ENCLOSURE SPECIFICATION CUSTOMISING As a vertically integrated manufacturer Walsall can customise the AL range at each stage of the production process to meet individual customer requirements Dimensions Material box Finish Weight empty Cover fixing Gasket 110mm x 110mm x 65mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 0.4Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 6mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body External lugs with 8mm clearance holes DIN 20mm rail or mounting plate to suit Earthing Entries External Mounting Internal Mounting All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rail Horizontal Rail WDU 2.5 1x14 1x14 WDU 4 1x11 1x11 A GUIDE TO ENTRY CAPACITY WDU 6 1x8 1x8 WDU 10 1x6 1x6 Gland Size mm Side A + B Side C + D 16 4 4 20 3 3 25 2 2 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded ORDERING INFORMATION Material Aluminium Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, aluminium 47 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com EEx e Terminal Box AL11 EEx e U Component Approved Enclosure AL12 EEx ia Terminal Box AL13 CES6 AL1MP tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 48 EEx e and EEx i Terminal Boxes - Aluminium Type AL2 - 120mm x 120mm x 80mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 EEx e and EEx i Terminal Boxes - Aluminium Type AL3 - 150mm x 120mm x 80mm Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Entries External Mounting Internal Mounting Group II Cat 1,2 Dimensions Material box Finish Weight empty Cover fixing Gasket 150mm x 120mm x 80mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 0.5Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50C 6mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body External lugs with 8mm clearance holes DIN 20mm rail or mounting plate to suit Earthing Entries External Mounting Internal Mounting All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rail Horizontal Rail WDU 2.5 1x16 1x16 WDU 4 1x13 1x13 All Dimensions in mm A GUIDE TO ENTRY CAPACITY WDU 6 1x9 1x9 WDU 10 1x7 1x7 Gland Size mm Side A + B Side C + D 20 6 6 A GUIDE TO PHYSICAL TERMINAL CAPACITY 25 3 3 32 2 2 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, aluminium 49 Verticle Rail Horizontal Rail WDU 2.5 1x22 1x16 WDU 4 1x18 1x13 A GUIDE TO ENTRY CAPACITY WDU 6 1x13 1x9 WDU 10 1x10 1x7 Gland Size mm Side A + B Side C + D 20 8 6 25 4 3 32 2 2 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded ORDERING INFORMATION Material Aluminium ATEX/GOST/UL ENCLOSURE SPECIFICATION 120mm x 120mm x 80mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 0.45Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 6mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body External lugs with 8mm clearance holes DIN 20mm rail or mounting plate to suit Earthing T3,T4,T5,T6 II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66/67 to EN60529:1992 Maximum 9 Watts. Except for dust applications where the maximum is 4.5 Watts. Ingress protection Power dissipation ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Zones 0,1,2,21,22 HAZARDOUS AREA SPECIFICATION II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66/67 to EN60529:1992 Maximum 9 watts. Except for dust applications where the maximum is 4.5 Watts Ingress protection Power dissipation EEx e II and EE x ia IIC ORDERING INFORMATION EEx e Terminal Box AL21 EEx e U Component Approved Enclosure AL22 EEx ia Terminal Box AL23 CES6 AL2MP tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Aluminium Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, aluminium EEx e Terminal Box AL31 EEx e U Component Approved Enclosure AL32 EEx ia Terminal Box AL33 CES6 AL3MP tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 50 EEx e and EEx i Terminal Boxes - Aluminium Type AL4 - 150mm x 150mm x 90mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 EEx e and EEx i Terminal Boxes - Aluminium Type AL5 - 190mm x 150mm x 90mm Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Entries External Mounting Internal Mounting Group II Cat 1,2 Dimensions Material box Finish Weight empty Cover fixing Gasket 190mm x 150mm x 90mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 0.7Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 6mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body. External lugs with 8mm clearance holes DIN 20mm rail or mounting plate to suit Earthing Entries External Mounting Internal Mounting All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rail Horizontal Rail WDU 2.5 1x22 1x22 WDU 4 1x18 1x18 All Dimensions in mm A GUIDE TO ENTRY CAPACITY WDU 6 1x13 1x13 WDU 10 1x10 1x10 Gland Size mm Side A + B Side C + D 20 8 8 A GUIDE TO PHYSICAL TERMINAL CAPACITY 25 5 5 32 3 3 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, aluminium 51 Verticle Rail Horizontal Rail WDU 2.5 1x30 1x22 WDU 4 1x24 1x18 A GUIDE TO ENTRY CAPACITY WDU 6 1x18 1x13 WDU 10 1x14 1x10 Gland Size mm Side A + B Side C + D 20 8 10 25 5 7 32 3 3 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded ORDERING INFORMATION Material Aluminium ATEX/GOST/UL ENCLOSURE SPECIFICATION 150mm x 150mm x 90mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 0.6Kg. Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 6mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body External lugs with 8mm clearance holes DIN 20mm rail or mounting plate to suit Earthing T3,T4,T5,T6 II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66/67 to EN60529:1992 Maximum 9 Watts. Except for dust applications where the maximum is 4.5 Watts Ingress protection Power dissipation ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Zones 0,1,2,21,22 HAZARDOUS AREA SPECIFICATION II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66/67 to EN60529:1992 Maximum 9 Watts. Except for dust applications where the maximum is 4.5 Watts Ingress protection Power dissipation EEx e II and EE x ia IIC ORDERING INFORMATION EEx e Terminal Box AL41 EEx e U Component Approved Enclosure AL42 EEx ia Terminal Box AL43 CES6 AL4MP tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Aluminium Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, aluminium EEx e Junction Box AL51 EEx e U Component Approved Enclosure AL52 EEx ia Junction Box AL53 CES6 AL5MP tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 52 EEx e and EEx i Terminal Boxes - Aluminium Type AL6 - 190mm x 190mm x 100mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T3,T4,T5,T6 Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos II 2 GD, II 1 GD T6,T5,T4,T3 EEx e II and EEx ia IIC T6(-50˚C to +40˚C), T5(+55˚C), T4(+85˚C), T3(+120˚C) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99ATEX3199 and Sira 00ATEX3027U GOST ‘R’ POCC GB. гБ05.BO1131 IP66/67 to EN60529:1992 Maximum 9 watts. Except for dust applications where the maximum is 4.5 Watts Ingress protection Power dissipation ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket 190mm x 190mm x 100mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 1.0Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 6mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body External lugs with 8mm clearance holes DIN 20mm rail or mounting plate to suit Earthing Entries External Mounting Internal Mounting All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rail Horizontal Rail WDU 2.5 1x30 1x30 WDU 4 1x24 1x24 A GUIDE TO ENTRY CAPACITY WDU 6 1x18 1x18 WDU 10 1x14 1x14 Gland Size mm Side A + B Side C + D 20 14 14 25 8 8 32 4 4 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded ORDERING INFORMATION Material Aluminium Optional Extras 6mm earthing stud welded to cover Equipment mounting plate, aluminium 53 EEx e Terminal Box AL61 EEx e U Component Approved Enclosure AL62 EEx ia Terminal Box AL63 CES6 AL6MP tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 54 EEx e Junction Box With Pillar or MK Terminals - Glass Reinforced Polyester Type GVU - 110mm x 110mm x 65mm PART 1.6 GVU JUNCTION BOX A small heavy duty GRP junction box with deep threaded enteries designed to accommodate 4 + E pillar terminals or 5 + E MK type terminals. The boxes have ingress protection to IP66. EEx e II Page 56 Type GVU/MK 110mm x 110mm x 90mm with MK terminals Page 56 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Type GVU/P 110mm x 110mm x 90mm with pillar terminals Zones 1,2,21,22 II 2 GD EEx e II T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA03ATEX3293 GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Mounting 110mm x 110mm x 65mm Carbon loaded anti-static glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 allen head stainless steel screws 1.2 mm one piece solid nitrile rubber Through 10mm holes moulded into base ENTRY SPECIFICATION 1 x 20mm EEx e threaded hole at A,B,C and D as standard All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option TERMINAL SPECIFICATION Operating Voltage Operating current Terminal capacity Pillar Type 420v 16amps 2 2.5mm MK3/6 Type 420v 32amps 2 2.5mm All Dimensions in mm ORDERING INFORMATION Enclosure Dimensions 110mm x 110mm x 65mm 110mm x 110mm x 65mm 55 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Terminal Type Pillar MK3/6 Number of Terminals 4+E 5+E tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code GVU/P GVU/MK 56 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL1 - 80mm x 75mm x 55mm PART 1.7 GL RANGE EEx e II and EE x ia IIC Zones 0,1,2,21,22 T6 Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Small to large EEx e and EEx i approved terminal boxes, compression moulded from glass reinforced polyester. The terminal boxes have Ingress Protection to IP66. Type GL1 – 80mm x 75mm x 55mm Page 58 Type GL2 – 110mm x 75mm x 55mm Page 59 Type GL3 – 160mm x 75mm x 55mm Page 60 Type GL4 – 190mm x 75mm x 55mm Page 61 Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 7.5 Watts at +40C and 1.6 Watts at +50˚C Except for dust applications where the maxima are 3.3 Watts at +40˚C and 0.8 Watts at +50˚C ENCLOSURE SPECIFICATION Type GL5 – 122mm x 120mm x 90mm Page 62 Type GL6 – 220mm x 120mm x 90mm Page 63 Type GL7 – 160mm x 160mm x 90mm Page 64 Type GL8 – 260mm x 160mm x 90mm Page 65 Type GL9 – 360mm x 160mm x 90mm Page 66 Type GL10 – 560mm x 160mm x 90mm Page 67 Type GL11 – 255mm x 250mm x 120mm Page 68 Type GL12 – 400mm x 250mm x 120mm Page 69 Type GL13 – 405mm x 400mm x 120mm Page 70 Type GL14 – 405mm x 400mm x 165mm Page 71 Dimensions Material Finish Weight empty Cover fixing Gasket Earthing Entry Mounting 80mm x 75mm x 55mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 0.35 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 4.5mm clearance holes moulded into the body All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Horizontal Rail A GUIDE TO ENTRY CAPACITY MK 3 1x5 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 16 2 1 20 1 1 25 0 0 CUSTOMISING As a vertically integrated manufacturer Walsall can customise the GL range at each stage of the production process to meet individual customer requirements. ORDERING INFORMATION Description Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each 57 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com EEx e Terminal Box GL101 GL111 GL121 GL131 EEx e U Component Approved Enclosure GL102 GL112 GL122 GL132 EEx ia Terminal Box GL103 GL113 GL123 GL133 GL/ES GL1/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 58 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL2 - 110mm x 75mm x 55mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL3 - 160mm x 75mm x 55mm ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Entry Mounting Zones 0,1,2,21,22 T6 Group II Cat 1,2 II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 8.0 Watts at +40˚C and 2.0 Watts at +50˚C Except for dust applications where the maxima are 4.0 Watts at +40˚C and 1.0 Watts at +50˚C Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 9.0 Watts at +40˚C and 3.0 Watts at +50˚C Except for dust applications where the maxima are 4.5 Watts at +40˚C and 1.5 Watts at +50˚C ENCLOSURE SPECIFICATION 110mm x 75mm x 55mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 0.4 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 4.5mm clearance holes moulded into the body Dimensions Material Finish Weight empty Cover fixing Gasket Earthing Entry Mounting 160mm x 75mm x 55mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 0.5 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 4.5mm clearance holes moulded into the body All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY All Dimensions in mm A GUIDE TO ENTRY CAPACITY MK 3 1x8 Horizontal Rail Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 16 3 1 A GUIDE TO PHYSICAL TERMINAL CAPACITY 20 2 1 25 0 0 ORDERING INFORMATION Horizontal Rail A GUIDE TO ENTRY CAPACITY MK 3 1x12 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 16 5 1 20 4 1 25 0 0 ORDERING INFORMATION Description EEx e Terminal Box GL201 GL211 GL221 GL231 Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each 59 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Weight empty Cover fixing Gasket Earthing EEx e II and EE x ia IIC EEx e U Component Approved Enclosure GL202 GL212 GL222 GL232 EEx ia Terminal Box GL203 GL213 GL223 GL233 GL/ES GL2/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Description Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each EEx e Terminal Box GL301 GL311 GL321 GL331 EEx e U Component Approved Enclosure GL302 GL312 GL322 GL332 EEx ia Terminal Box GL303 GL313 GL323 GL333 GL/ES GL3/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 60 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL4 - 190mm x 75mm x 55mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL5 - 122mm x 120mm x 90mm ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Entry Mounting Zones 0,1,2,21,22 T6 Group II Cat 1,2 II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 9.4 Watts at +40˚C and 3.5 Watts at +50˚C Except for dust applications where the maxima are 4.7 Watts at +40˚C and 1.75 Watts at +50˚C Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 9.4 Watts at +40˚C and 3.5 Watts at +50˚C Except for dust applications where the maxima are 4.7 Watts at +40˚C and 1.75 Watts at +50˚C ENCLOSURE SPECIFICATION 190mm x 75mm x 55mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 0.85 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 6.5mm clearance holes moulded into the body Dimensions Material Finish Weight empty Cover fixing Gasket Earthing Entry Mounting 122mm x 120mm x 90mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 0.85 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 6.5mm clearance holes moulded into the body All Dimensions in mm All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY A GUIDE TO ENTRY CAPACITY MK 3 1x12 Horizontal Rail Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 16 7 1 A GUIDE TO PHYSICAL TERMINAL CAPACITY 20 5 1 25 0 0 ORDERING INFORMATION Horizontal Rail WDU 2.5 1x14 WDU 4 1x12 A GUIDE TO ENTRY CAPACITY WDU 6 1x9 WDU 10 1x6 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 20 4 2 25 2 1 32 1 1 ORDERING INFORMATION Description EEx e Terminal Box GL401 GL411 GL421 GL431 Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each 61 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Weight empty Cover fixing Gasket Earthing EEx e II and EE x ia IIC EEx e U Component Approved Enclosure GL402 GL412 GL422 GL432 EEx ia Terminal Box GL403 GL413 GL423 GL433 GL/ES GL4/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Description Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each EEx e Terminal Box GL501 GL511 GL521 GL531 EEx e U Component Approved Enclosure GL502 GL512 GL522 GL532 EEx ia Terminal Box GL503 GL513 GL523 GL533 GL/ES GL5/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 62 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL6 - 220mm x 120mm x 90mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL7 - 160mm x 160mm x 90mm ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Entry Mounting Zones 0,1,2,21,22 T6 Group II Cat 1,2 II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 9.4 Watts at +40ºC and 3.5 Watts at +50ºC Except for dust applications where the maxima are 4.7 Watts at +40ºC and 1.75 Watts at +50ºC Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 10.4 Watts at +40˚C and 4.3 Watts at +50˚C Except for dust applications where the maxima are 5.2 Watts at +40˚C and 2.2 Watts at +50˚C ENCLOSURE SPECIFICATION 220mm x 120mm x 90mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 1.0 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 6.5mm clearance holes moulded into the body. Dimensions Material Finish Weight empty Cover fixing Gasket Earthing Entry Mounting 160mm x 160mm x 90mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 1.1 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 6.5mm clearance holes moulded into the body All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Horizontal Rail WDU 2.5 1x34 WDU 4 1x29 All Dimensions in mm A GUIDE TO ENTRY CAPACITY WDU 6 1x21 WDU 10 1x16 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 20 6 2 A GUIDE TO PHYSICAL TERMINAL CAPACITY 25 5 1 32 3 1 ORDERING INFORMATION Horizontal Rail WDU 2.5 1x20 WDU 4 1x17 A GUIDE TO ENTRY CAPACITY WDU 6 1x12 WDU 10 1x9 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 20 8 6 25 3 2 32 2 1 ORDERING INFORMATION Description EEx e Terminal Box GL601 GL611 GL621 GL631 Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each 63 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Weight empty Cover fixing Gasket Earthing EEx e II and EE x ia IIC EEx e U Component Approved Enclosure GL602 GL612 GL622 GL632 EEx ia Terminal Box GL603 GL613 GL623 GL633 GL/ES GL6/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Description Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each EEx e Terminal Box GL701 GL711 GL721 GL731 EEx e U Component Approved Enclosure GL702 GL712 GL722 GL732 EEx ia Terminal Box GL703 GL713 GL723 GL733 GL/ES GL7/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 64 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL8 - 260mm x 160mm x 90mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL9 - 360mm x 160mm x 90mm ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Entry Mounting Zones 0,1,2,21,22 T6 Group II Cat 1,2 II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 12.0 Watts at +40˚C and 5.0 Watts at +50˚C Except for dust applications where the maxima are 6.0 Watts at +40˚C and 2.5 Watts at +50˚C Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 13.8 Watts at +40˚C and 6.2 Watts at +50˚C Except for dust applications where the maxima are 6.9 Watts at +40˚C and 3.1 Watts at +50˚C ENCLOSURE SPECIFICATION 260mm x 160mm x 90mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 1.7 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 6.5mm clearance holes moulded into the body Dimensions Material Finish Weight empty Cover fixing Gasket Earthing Entry Mounting 360mm x 160mm x 90mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 2.0 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 6.5mm clearance holes moulded into the body All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Horizontal Rail WDU 2.5 1x40 WDU 4 1x34 All Dimensions in mm A GUIDE TO ENTRY CAPACITY WDU 6 1x25 WDU 10 1x19 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 20 14 6 A GUIDE TO PHYSICAL TERMINAL CAPACITY 25 6 2 32 4 1 ORDERING INFORMATION Horizontal Rail WDU 2.5 1x60 WDU 4 1x51 A GUIDE TO ENTRY CAPACITY WDU 6 1x37 WDU 10 1x29 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 20 20 6 25 9 2 32 6 1 ORDERING INFORMATION Description EEx e Terminal Box GL801 GL811 GL821 GL831 Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each 65 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Weight empty Cover fixing Gasket Earthing EEx e II and EE x ia IIC EEx e U Component Approved Enclosure GL802 GL812 GL822 GL832 EEx ia Terminal Box GL803 GL813 GL823 GL833 GL/ES GL8/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Description Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each EEx e Terminal Box GL901 GL911 GL921 GL931 EEx e U Component Approved Enclosure GL902 GL912 GL922 GL932 EEx ia Terminal Box GL903 GL913 GL923 GL933 GL/ES GL9/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 66 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL10 - 560mm x 160mm x 90mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL11 - 255mm x 250mm x 120mm ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Entry Mounting Zones 0,1,2,21,22 T6 Group II Cat 1,2 II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 13.8 Watts at +40˚C and 6.2 Watts at +50˚C Except for dust applications where the maxima are 6.9 Watts at +40˚C and 3.1 Watts at +50˚C Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 15.5 Watts at +40˚C and 6.4 Watts at +50˚C Except for dust applications where the maxima are 7.75 Watts at +40˚C and 3.2 Watts at +50˚C ENCLOSURE SPECIFICATION 560mm x 160mm x 90mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 3.7 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 6.5mm clearance holes moulded into the body Dimensions Material Finish Weight empty Cover fixing Gasket Earthing Entry Mounting 255mm x 250mm x 120mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 2.7 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 6.5mm clearance holes moulded into the body All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Horizontal Rail WDU 2.5 1x100 WDU 4 1x84 All Dimensions in mm A GUIDE TO ENTRY CAPACITY WDU 6 1x62 WDU 10 1x49 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 20 34 6 A GUIDE TO PHYSICAL TERMINAL CAPACITY 25 16 2 32 10 1 ORDERING INFORMATION Horizontal Rail WDU 2.5 2x39 WDU 4 2x33 A GUIDE TO ENTRY CAPACITY WDU 6 2x24 WDU 10 2x18 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 20 17 14 25 10 8 32 5 4 ORDERING INFORMATION Description EEx e Terminal Box GL1001 GL1011 GL1021 GL1031 Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each 67 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Weight empty Cover fixing Gasket Earthing EEx e II and EE x ia IIC EEx e U Component Approved Enclosure GL1002 GL1012 GL1022 GL1032 EEx ia Terminal Box GL1003 GL1013 GL1023 GL1033 GL/ES GL10/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Description Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each EEx e Terminal Box GL1101 GL1111 GL1121 GL1131 EEx e U Component Approved Enclosure GL1102 GL1112 GL1122 GL1132 EEx ia Terminal Box GL1103 GL1113 GL1123 GL1133 GL/ES GL11/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 68 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL12 - 400mm x 250mm x 120mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T6 Group II Cat 1,2 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL13 - 405mm x 400mm x 120mm ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation Entry Mounting Zones 0,1,2,21,22 T6 Group II Cat 1,2 II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 15.5 Watts at +40˚C and 6.4 Watts at +50˚C Except for dust applications where the maxima are 7.75 Watts at +40˚C and 3.2 Watts at +50˚C Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 31.4 Watts at +40˚C and 11.2 Watts at +50˚C Except for dust applications where the maxima are 15.7 Watts at +40˚C and 5.6 Watts at +50˚C ENCLOSURE SPECIFICATION 400mm x 250mm x 120mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 3.4 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 6.5mm clearance holes moulded into the body Dimensions Material Finish Weight empty Cover fixing Gasket Earthing Entry Mounting 405mm x 400mm x 120mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 5.1 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 6.5mm clearance holes moulded into the body All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Horizontal Rail WDU 2.5 2x68 WDU 4 2x57 All Dimensions in mm A GUIDE TO ENTRY CAPACITY WDU 6 2x42 WDU 10 2x33 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 20 32 14 A GUIDE TO PHYSICAL TERMINAL CAPACITY 25 18 8 32 9 4 ORDERING INFORMATION Horizontal Rail WDU 2.5 3x68 WDU 4 3x57 A GUIDE TO ENTRY CAPACITY WDU 6 3x42 WDU 10 3x33 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 20 32 29 25 18 16 32 9 9 ORDERING INFORMATION Description EEx e Terminal Box GL1201 GL1211 GL1221 GL1231 Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each 69 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Weight empty Cover fixing Gasket Earthing EEx e II and EE x ia IIC EEx e U Component Approved Enclosure GL1202 GL1212 GL1222 GL1232 EEx ia Terminal Box GL1203 GL1213 GL1223 GL1233 GL/ES GL12/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Description Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each EEx e Terminal Box GL1301 GL1311 GL1321 GL1331 EEx e U Component Approved Enclosure GL1302 GL1312 GL1322 GL1332 EEx ia Terminal Box GL1303 GL1313 GL1323 GL1333 GL/ES GL13/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 70 EEx e and EEx i Terminal Boxes - Glass Reinforced Polyester Type GL14 - 405mm x 400mm x 165mm EEx e II and EE x ia IIC Zones 0,1,2,21,22 T6 Group II Cat 1,2 ATEX/GOST/UL HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection Power dissipation II 2 GD, II 1 GD T6 EEx e II T6 and EEx ia IIC T6 -50ºC to +50ºC (T6), +55ºC (T5), +60ºC (T4) Zones 0,1,2,21,22. Groups IIA, IIB, IIC Sira 99 ATEX 3200 and Sira 99 ATEX 3028U GOST ‘R’ POCC GB. гБ05.BO1131 IP66 to EN 60529:1992 Maximum 31.4 Watts at +40˚C and 11.2 Watts at +50˚C Except for dust applications where the maxima are 15.7 Watts at +40˚C and 5.6 Watts at +50˚C ENCLOSURE SPECIFICATION Dimensions Material Finish Weight empty Cover fixing Gasket Earthing Entry Mounting 405mm x 400mm x 165mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request 5.1 Kg Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 6.5mm clearance holes moulded into the body All Dimensions in mm A GUIDE TO PHYSICAL TERMINAL CAPACITY Horizontal Rail WDU 2.5 3x68 WDU 4 3x57 A GUIDE TO ENTRY CAPACITY WDU 6 3x42 WDU 10 3x33 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded Gland Size mm Side A + B Side C + D 20 42 38 25 27 25 32 14 14 ORDERING INFORMATION Description Enclosure only Enclosure with steel earth plate Enclosure with brass earth plate Enclosure with stainless steel earth plate EEx e Terminal Box GL1401 GL1411 GL1421 GL1431 Optional Extras Internal/ External 6mm brass earth stud Equipment mounting plate, coated mild steel Cover hinge each 71 EEx e U Component Approved Enclosure GL1402 GL1412 GL1422 GL1432 EEx ia Terminal Box GL1403 GL1413 GL1423 GL1433 GL terminal boxes installed by Maersk Oil and Gas GL/ES GL14/MP GL/CH tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 72 EEx d IIC Terminal Box - Cast Iron Type E115 - 117mm x 117mm x 70mm PART 1.8 E RANGE EEx d IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION A range of small very robust EEx d IIB and EEx d IIC cast iron terminal boxes suitable for MK type terminals. The terminal boxes have Ingress Protection of IP66 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection Power dissapation Type E115 – EEx d IIC 117mm x 117mm x 70mm Page 74 Type E210 – EEx d IIB 145mm x 106mm x 65mm Page 75 Type E220 – EEx d IIB 104mm diam x 59mm Page 76 II 2 GD EEx d IIC T6 -40˚C to +50˚C Zones 1,2,21,22 Groups IIA, IIB, IIC SIRA02ATEX1311 GOST ‘R’ POCC GB. гБ05. BO1131 IP66 to EN60529:1992 5 Watts ENCLOSURE SPECIFICATION Dimensions Material Finish Colour Weight Cover fixing Gasket Earthing Mounting 117mm x 117mm x 70mm Cast iron to 180BS1452:1977 Zinc rich epoxy powder primer plus epoxy powder top coat Black 3.5 Kg M6 allen head stainless steel screws Nitrile rubber O ring Base- internal and external EEx e brass clamps Cover- internal EEx e brass clamp Integral 8mm fixing holes in base ENTRY SPECIFICATION 1 x 20mm EEx d entries at A, B, C, D as standard All entries filled with EE x d stopping plugs as standard 25mm entries available as an option All Dimensions in mm ORDERING INFORMATION Terminal Type MK3/8 MK6/6 Number of Terminals 8 6 Product Code E115001 E115002 For 25mm entries add /25 to product code eg. E115001/25 73 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 74 EEx d IIB Terminal Box - Cast Iron Type E210 - 145mm x 106mm x 65mm EEx d IIB Zones 1,2,21,22 T6 EEx d IIB Circular Terminal Box - Cast Iron Type E220 - 105mm diameter x 59mm Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION II 2 GD EEx d IIB T6 -20˚C to +40˚C Zones 1,2,21,22. Groups IIA, IIB SIRA01ATEX1129 GOST ’R’ POCC GB. гБ05. B01131 IP66 to EN60529:1992 Marking to94/9/EC Type of protection Temperature class Area classification Certification No. Ingress Protection ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting EEx d IIB II 2 GD EEx d IIB T6 -20˚C to +40˚C Zones 1,2,21,22. Goup IIA, IIB SIRA01 ATEX1130 GOST’R’ POCC GB. гБ05. B01131 IP66 to EN60529: 1992 ENCLOSURE SPECIFICATION 145mm x 106mm x 65mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat 1.5 Kg M6 allen head stainless steel screws By grease Internal and external EEx e brass clamps on base Steel mounting strap. 8mm diameter fixing holes Dimensions Material Finish Colour Weight Cover fixing Gasket Earthing Mounting 104mm diameter x 59mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 2 Kgs M6 allen stainless steel screws By grease Internal and external EEx e clamps on base Steel mounting strap, 8mm fixing holes ENTRY SPECIFICATION ENTRY SPECIFICATION 1 x 20mm EEx d entries at A, B, C, D, E, F as standard All entries filled with EE x d stopping plugs as standard 25mm entries available as an option 1 x 20mm EEx d entries at A, B, C, D as standard All entries filled with EE x d stopping plugs as standard 25mm entries available as an option All Dimensions in mm All Dimensions in mm ORDERING INFORMATION Terminal Type MK3/12 MK6/6 Number of Terminals 12 6 Product Code E211 E212 For 25mm entries add /25 to product code eg. E214/25 75 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com ORDERING INFORMATION Terminal Type MK3/4 Number of Terminals 4 Product Code E220 For 25mm entries add /25 to product code eg. E220/25 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 76 EEx d IIB Terminal Box - Cast Aluminium, Cast Iron & Cast Stainless Steel Type ASMT130 - 210mm x 185mm x 152mm PART 1.9 ASMT RANGE EEx d IIB T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Medium to large EEx d IIB approved terminal boxes manufactured in Cast Aluminium, Cast Iron and Cast Stainless Steel with a two pack coating consisting of a specially formulated zinc rich epoxy primer followed by a standard epoxy top coat. The terminal boxes have Ingress Protection to IP66 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Power dissipation Cast Aluminium Type ASMT130/AL – 210mm x 185mm x 152mm Page 78 Type ASMT150/AL – 335mm x 310mm x 200mm Page 79 Cast Iron Page 78 Finish Type ASMT150/CI – 335mm x 310mm x 200mm Page 79 Type ASMT170/CI – 560mm x 560mm x 245mm Page 80 Weight empty Cover fixing Gasket Earthing Mounting Cast Stainless Steel Type ASMT130/SS – 210mm x 185mm x 152mm Page 78 Type ASMT150/SS – 335mm x 310mm x 200mm Page 79 Type ASMT170/SS – 560mm x 560mm x 245mm Page 80 II 2 GD EEx d IIB T6 -20˚C to +40˚C Zones 1,2,21,22 . Groups IIA, IIB SIRA03ATEX1215 and SIRA03ATEX1187U GOST’R’ POCC GB. гБ05. B01131 IP66 to EN60529:1992 Maximum 7.0 Watts at +40˚C ENCLOSURE SPECIFICATION Dimensions Material Type ASMT130/CI – 210mm x 185mm x 152mm Zones 1,2,21,22 210mm x 185mm x 152mm Cast aluminium LM6 Cast iron to 180BSI1452:1997 Cast stainless steel 316l (1.4404) Zinc rich epoxy powder primer and epoxy powder top coat black Cast aluminium 6.0Kg, Cast iron 20Kg , Cast stainless 21Kg Hinged with M6 allen head stainless steel screws One piece closed cell 4mm neoprene Base- internal and external EEx e brass clamp Cover – internal EEx e brass clamps 2 steel mounting straps. 8mm diameter fixing holes All Dimensions in mm ENTRY SPECIFICATION EEx d threaded holes through base All entries are fitted with EEx d stopping plugs or cable glands as standard unless otherwise specified A GUIDE TO PHYSICAL TERMINAL CAPACITY CUSTOMISING As a vertically integrated manufacturer Walsall can customise the ASMT range at each stage of the production process to meet individual customer requirements. Verticle Rail Horizontal Rail WDU 2.5 1x21 1x15 WDU 4 1x17 1x12 WDU 6 1x13 1x9 A GUIDE TO ENTRY CAPACITY WDU 10 1x9 1x7 Gland Size mm Side A + B Side C + D 20 5 5 25 5 5 32 2 3 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded ORDERING INFORMATION Material Cast Aluminium Cast Iron Cast Stainless Steel 77 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com EEx d Terminal Box ASMT130/AL ASMT130/CI ASMT130/SS EEx e U Component Approved Enclosure ASMT130U/AL ASMT130U/CI ASMT130U/SS tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 78 EEx d IIB Terminal Box - Cast Aluminium, Cast Iron & Cast Stainless Steel Type ASMT150 - 335mm x 310mm x 200mm EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST EEx d IIB HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Power dissipation Finish Weight empty Cover fixing Gasket Earthing Mounting Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION II 2 GD EEx d IIB T6 -40ºC to +50ºC Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X and SIRA00ATEX1188U (-20ºC) TRL03ATEX11029X (-40ºC) GOST’R’ POCC GB. гБ05. B01131 IP66 to EN60529:1992 Maximum 62 Watts at +50˚C Marking to 94/9/EC Type of protection Temperature class Area classification Certification Number Ingress protection Power dissipation ENCLOSURE SPECIFICATION Dimensions Material EEx d IIB Terminal Box - Cast Iron & Cast Stainless Steel Type ASMT170 - 560mm x 560mm x 245mm II 2 GD EEx d IIB T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1267X and SIRA00ATEX1189U (-20ºC) TRL03ATEX11030X (-40ºC) GOST’R’ POCC GB. гБ05. B01131 IP66 to EN60529:1992 Maximum 200 Watts at +50˚C ENCLOSURE SPECIFICATION 335mm x 310mm x 200mm Cast aluminium LM6 Cast iron to 180BSI1452:1997 Cast stainless steel 316L (1.4404) Zinc rich epoxy powder primer and epoxy powder top coat, black Cast aluminium 17Kgs, Cast iron 50Kgs , cast stainless 52Kgs Hinged with M6 allen head stainless steel screws One piece closed cell 4mm neoprene Base- internal and external EEx e brass clamps Cover – internal EEx e brass clamp 2 steel mounting straps. 8mm diameter fixing holes Dimensions Material Finish Weight empty Cover fixing Gasket Earthing All Dimensions in mm Mounting 560mm x 560mm x 245mm Cast iron to 180BSI1452:1997 Cast stainless steel 316L Zinc rich epoxy powder primer and epoxy powder top coat Cast iron 190Kgs , cast stainless 195Kgs Hinged with M10 allen head stainless steel screws One piece closed cell 4mm neoprene Base- internal and external EEx e brass clamps Cover – internal EEx e brass clamp 2 steel U shaped mounting straps 10mm diameter fixing holes All Dimensions in mm ENTRY SPECIFICATION EEx d threaded holes through base. All entries are fitted with EEx d stopping plugs or cable glands as standard unless otherwise specified. ENTRY SPECIFICATION EEx d threaded holes through base All entries are fitted with EEx d stopping plugs or cable glands as standard unless otherwise specified A GUIDE TO PHYSICAL TERMINAL CAPACITY Verticle Rails Horizontal Rails WDU 2.5 2x45 2x39 WDU 4 2x37 2x33 WDU 6 2x27 2x24 A GUIDE TO ENTRY CAPACITY WDU 10 2x22 2x19 Gland Size mm Side A + B Side C + D 20 11 11 25 8 8 32 7 7 A GUIDE TO PHYSICAL TERMINAL CAPACITY 40 3 3 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded 79 Verticle Rails Horizontal Rails WDU 2.5 4x78 4x78 WDU 4 4x33 4x33 WDU 6 4x24 4x24 WDU 10 4x19 4x19 Gland Size mm Side A + B Side C + D 20 12 12 25 12 12 32 6 6 40 6 6 50 3 3 Note: This is a guide to Physical Terminal Capacity only. Installers must ensure that the maximum power dissapation given above is not exceeded ORDERING INFORMATION Material Cast Aluminium Cast Iron Cast Stainless Steel 50 3 3 A GUIDE TO ENTRY CAPACITY ORDERING INFORMATION EEx d Terminal Box ASMT150/AL ASMT150/CI ASMT150/SS EEx e U Component Approved Enclosure ASMT150U/AL ASMT150U/CI ASMT150U/SS tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Material Cast Iron Cast Stainless Steel EEx d Terminal Box ASMT170/CI ASMT170/SS EEx e U Component Approved Enclosure ASMT170U/CI ASMT170U/SS tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 80 PART 2.0 CONTROL IN GRP, STAINLESS STEEL AND ALUMINIUM ENCLOSURES Comprehensive ranges of standard and customised EEx edm IIC one, two and three function local control stations and customised multifunction control panels in enclosures manufactured from glass reinforced polyester, fabricated stainless steel and fabricated aluminium. 2.1 CF Range Page 83 EEx e, EEx ed, and EEx em control functions and actuators 2.2 LCP Range Page 89 Standard and customised EEx edm local control stations in glass reinforced polyester enclosures 2.3 LCS Range Page 101 Standard and customised EEx edm local control stations in stainless steel enclosures 2.4 LCA Range Page 111 Standard and customised EEx edm local control stations in fabricated aluminium enclosures 2.5 GVU Range Page 121 Standard EEx ed heavy duty local control stations in glass reinforced polyester enclosures 2.6 GLCP Range Page 125 Customised EEx edm control panels in glass reinforced polyester enclosures 2.7 XLCP Range Page 127 Customised EEx edm control panels in stainless steel enclosures 81 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 82 EEx edm Control Functions Introduction PART 2.1 CF RANGE EEx edm IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST INTRODUCTION A comprehensive range of EEx e, EEx de and EEx em control switches , contact blocks, indicator lamps and measuring instruments for installation in EEx approved enclosures manufactured in glass reinforced polyester, stainless steel and aluminium. EEx edm control stations and control panels are made up from two sets of Ex approved components, control functions and enclosures. Note a control function is defined as an electrical operating module (contact block) plus an actuator (pushbutton). The switches, contact blocks, indicators and measuring instruments of the control function range use a variety of types of protection depending on the application. For example switches and contact blocks, that naturally produce sparking during their operation, use type of protection ‘d’, whereas an LED indicator lamp may use encapsulation as its method of protection and will therefore be of type ‘q’ or ‘m’. Actuators must simply provide a suitable IP rating and must not leak in the event of a failure when mounted on the front of the enclosure. Introduction Page 84 Type CF 1 to 10 – EEx ed Control Switches Page 85 Type CF 11 to 32 – EEx ed Push Buttons Page 86 Type CF 33 to 37 – EEx em LED Indicators Page 87 Type CF 38 – EEx e Ammeters Page 88 Type MCBD/RCDD – EEx de MCB/RCD* Page 88 * These products will be introduced later in 2006 and are included for advanced notice only 83 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com The enclosures, that are generally manufactured from glass reinforced polyester, stainless steel and aluminium are EEx e approved with a minimum IP rating of 66 for gas and dust applications. The method for engineering an approved control system is shown in the diagram below. ‘e’, ‘ed’, ‘em’ control functions + ‘e’ enclosures = ‘e’, ‘ed’, ‘em’, ‘edm’ control systems tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 84 EEx edm Control Functions Type CF - EEx de Switches EEx de IIC Zones 1,2,21,22 EEx edm Control Functions Type CF - EEx de Pushbuttons T6 Group II Cat 2 ATEX/GOST Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. II 2 G EEx de II T6 -40˚C or -20˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA03ATEX1269U Dimensions Material Weight Contact 42mm x 42mm x 72mm GRP 0.04 Kgs Silver (gold optional) Group II Cat 2 ATEX/GOST II 2 G EEx de II T6 -40˚C or -20˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA03ATEX1269U 42mm x 42mm x 46mm GRP 0.04 Kgs Silver (gold optional) ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Operating Voltage Operating Current Terminal Capacity T6 ENCLOSURE SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Weight Contact Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. EEx de IIC Operating Voltage Operating Current Terminal Capacity 270 Volts 16 Amps 2.5mmsq 270 Volts 16 Amps 2.5mmsq 42 4 ORDERING INFORMATION 72 42 ORDERING INFORMATION Description Double pole on – off Double pole changeover Single pole changeover Two position Three position - Centre off Three position - Centre off Three position - Centre off Three position - Control Switch Three position - Control Switch Three position - Control Switch CONTACT ARRANGEMENTS Action Contacts* Product Code 1 CF1 Engage - Engage Engage - Engage 2 CF2 Engage - Engage - Engage 5 CF3 Engage - Engage 3 CF4 Engage - Engage - Engage 3 CF5 Engage - Engage - Spring 3 CF6 Spring - Engage - Spring 3 CF7 Spring - Engage - Spring 4 CF8 Spring - Engage - Spring 4 CF9 Spring - Engage - Spring 4 CF10 * See Contact Arrangements opposite Notes: 1 For small rotary actuator add /A 2 For small key lockable rotary actuator add /AK (2 position only) 3 For large rotary actuator add /B 4 For large lockable rotary actuator add /BL 5 Individual labelling to be customer specified 85 1 3 5 20º 90º 20º 90º 20º 90º 160º 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 2 4 20º 90º 20º 90º 160º 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Description Green pushbutton Green pushbutton Green pushbutton Red pushbutton Red pushbutton Red pushbutton Red mushroom pushbutton Red mushroom pushbutton Red mushroom pushbutton Red mushroom pushbutton Red mushroom pushbutton Red mushroom pushbutton Red mushroom pushbutton Red mushroom pushbutton Red mushroom pushbutton Emergency mushroom pushbutton Emergency mushroom pushbutton Emergency mushroom pushbutton Emergency mushroom pushbutton Emergency mushroom pushbutton Emergency mushroom pushbutton Double green and red pushbutton Action Spring Spring Spring Spring Spring Spring Spring Spring Spring latching pull release latching pull release latching pull release latching key release latching key release latching key release latching pull release latching pull release latching pull release latching key release latching key release latching key release Spring Contacts I n/o + I n/c 2n/o 2n/c I n/o + I n/c 2n/o 2n/c I n/o + I n/c 2n/o 2n/c I n/o + I n/c 2n/o 2n/c I n/o + I n/c 2n/o 2n/c I n/o + I n/c 2n/o 2n/c I n/o + I n/c 2n/o 2n/c I n/o + I n/c Product Code CF11 CF12 CF13 CF14 CF15 CF16 CF17 CF18 CF19 CF20 CF21 CF22 CF23 CF24 CF25 CF26 CF27 CF28 CF29 CF30 CF31 CF32 * See Contact Arrangements opposite Notes: 1 Button heads can be engraved with text as per customer requirement 2 Alternative button colours available on request. 46 42 CONTACT ARRANGEMENTS Single Double 8 1 8 1 5 4 5 4 I n/o + I n/c I n/o + I n/c Single Single 8 1 8 1 5 4 5 4 2n/c 2n/o tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 86 EEx edm Control Functions Type CF - EEx em LED Indicators EEx em IIC Zones 1,2,21,22 EEx edm Control Functions Type CF - EEx e Ammeters T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Light source EEx e II Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION II 2 G EEx em II T6 -40˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA04ATEX5056U LED cluster Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Terminal capacity II 2 G EEx e II T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX3380U 2.5mmsq ENCLOSURE SPECIFICATION Dimensions Material Weight Contact 42mm x 42mm x 82mm GRP 0.04 Kgs Silver (gold optional) ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Operating voltage Operating current Terminal Capacity Max power diss. AC 24-230 - 5% + 10% 0.005 Amps 2.5mmsq 1.2 Watts Standard Meter Scales Direct Operated 0 - 2 - 12 amps 0 - 5 - 30 amps 0 - 10 - 60 amps 4 Operated from current transformer with 1 amp secondary 0 - 60 - 360 amps 0 - 1 - 60 amps 0 - 80 - 480 amps 0 - 15 - 90 amps 0 - 100 - 600 amps 0 - 20 - 120 amps 0 - 150 - 900 amps 0 - 30 - 80 amps 0 - 200 - 1200 amps 0 - 40 - 240 amps 0 - 50 - 300 amps ORDERING INFORMATION 82 Description Ammeter 42 Scale To be Specified Product Code CF38 EEx de Control Functions Type MCBD/RCDD - EEx de MCB’s and RCD’s OUTLINE SPECIFICATION Marking to 94/9/EC Type of protection Area classification Certification No. MCB ORDERING INFORMATION Description Indicator Lamp Indicator Lamp Indicator Lamp Indicator Lamp Indicator Lamp 87 II 2 G EEx de II T6 Zones 1,2,21,22 . Groups IIA, IIB, IIC. TBA Colour Red Green Amber White Blue Product Code CF33 CF34 CF35 CF36 CF37 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Terminal cross section Main 2 x 10mmsq Rating 16 - 40Amps Number of poles 2 or 3 RCD Terminal cross section Tripping current RCD Rating Number of poles Main 2 x 10mmsq 30mA 25 - 63Amps 2 or 3 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 88 Local Control Station - Glass Reinforced Polyester Enclosure Type LCP100 - EEx de 16 amp General Purpose Switch PART 2.2 LCP RANGE EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Standard and customised EEx edm Local Control Stations in Glass Reinforced Polyester Enclosures. The LCP Range offers very robust local control stations. The minimum wall thickness of the enclosures is 6mm and all the actuators are metal clad with nickle plated brass housings. Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx de II C T6 -40˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Standard Control Stations Type LCP100 – 16amp General Purpose Switch Page 90 Type LCP110 – Pushbutton Page 91 Type LCP120 – Mushroom Pushbutton Page 92 Type LCP130 – Emergency Pushbutton Page 93 Type LCP140 – Position and Control Switch Page 94 Type LCP150 – LED Indicator Lamp Page 95 Type LCP160 – Ammeter Page 96 Type LCP170 – Double Pushbuttons Page 97 Type LCP180 – Double Pushbuttons Page 98 Customised Control Stations Type LCP200 – 2 Function Customised Control Stations Page 99 Dimensions Material Finish Weight Cover fixing Gasket Security Earthing Mounting 110mm x 110mm x 125mm Carbon loaded anti-static glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 allen head stainless steel screws 1.2 mm one piece solid nitrile rubber Switches with an off position have a padlock ‘off’ ‘facility as standard Internal EEx e brass clamps on base Through 7mm holes moulded into base ENTRY SPECIFICATION 1x20mm EEx e threaded entry in base at A as standard. The entry is fitted with a 20mm EEx e cable gland as standard. 25mm entries are available as an option. ELECTRICAL SPECIFICATION Type LCP300 – 3 Function Customised Control Stations Page 100 Walsall EEx de IIC switch. Certification No. SIRA 03ATEX1269U Operating Voltage Volts 230-270 Operating Current Amps 16 Conductor Size mmsq. Max 2.5 All Dimensions in mm ORDERING INFORMATION Description Double pole off/on Double pole changeover Single pole changeover Notes 1 2 3 89 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Action Engage- Engage Engage- Engage Engage- Engage- Engage 20º 90º 20º 90º 20º 90º 160º Contacts Labelling 1-3 2-4 5-7 6-8 0 - I Off - On 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 Product Code LCP101 LCP102 I - II LCP103 I - 2 LCP104 I - 0 - II LCP105 I -0- 2 LCP106 For 25 mm entries add/25 to Product Code e.g. LCP103/25 Alternative labelling to order. Alternative handle colour to order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 90 Local Control Station - Glass Reinforced Polyester Enclosure Type LCP110 - EEx de Single Pushbutton EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 Local Control Station - Glass Reinforced Polyester Enclosure Type LCP120 - EEx de Single Mushroom Pushbutton ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection II 2 GD EEx de IIC T6 -40˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA99ATEX3199 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection T6 Group II Cat 2 ATEX/GOST II 2 GD EEx de IIC T6 -40˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION 110mm x 110mm x 113mm Carbon loaded Glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 pan head stainless steel screws 1.2mm one piece solid nitrile rubber Internal EEx e brass clamps on base Through 7mm holes fixing strap Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting ENTRY SPECIFICATION 110mm x 110mm x 121mm Carbon loaded anti-static Glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 allen head stainless steel screws 1.2 mm one piece solid nitrile rubber Internal EEx e brass clamps on base Through 7mm holes moulded into base ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard The entry is fitted with a 20mm EEx e cable gland as standard 25mm entries are available as an option 1x20mm EEx e threaded hole base at A as standard. The entry is fitted with a 20mm EEx e cable gland as standard. 25mm entries are available as an option. ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U Operating Voltage Volts 230-270 Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting EEx de IIC Operating Current Amps 16 Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U. Conductor Size mmsq. Max 2.5 Operating Voltage Volts 230-270 Operating Current Amps 16 Conductor Size mmsq. Max 2.5 All Dimensions in mm All Dimensions in mm ORDERING INFORMATION ORDERING INFORMATION Description Green Pushbutton Description Action Contacts 8 1 8 1 91 Red Mushroom Pushbutton Action start LCP112 I LCP113 stop LCP114 For 25 mm entries add/25 to Product Code e.g. LCP113/25 Alternative labelling to order. Alternative button colours to order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Red Mushroom Pushbutton Red Mushroom Pushbutton Notes 1 2 3 Contacts Labelling Product Code 8 1 I LCP121 5 4 Stop LCP122 8 1 I LCP123 5 4 Stop LCP124 8 1 I LCP125 5 4 Stop LCP126 Spring LCP111 Spring 5 4 Notes 1 2 3 0 Product Code Spring 5 4 Red Pushbutton Labelling Pull release Key release For 25 mm entries add/25 to Product Code e.g. LCP123/25 Alternative labelling to order. Alternative button colours to order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 92 Local Control Station - Glass Reinforced Polyester Enclosure Type LCP130 - EEx de Single Emergency Pushbutton EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 Local Control Station - Glass Reinforced Polyester Enclosure Type LCP140 - EEx de Position and Control Switch ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection II 2 GD EEx de IIC T6 -40˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection T6 Group II Cat 2 ATEX/GOST II 2 GD EEx de IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION 110mm x 110mm x 121mm Carbon loaded anti-static Glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 allen head stainless steel screws 1.2 mm one piece solid nitrile rubber Internal EEx e brass clamps on base Through 7mm holes moulded into base Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting ENTRY SPECIFICATION 110mm x 110mm x 123mm Carbon loaded anti-static Glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 allen head stainless steel screws 1.2 mm one piece solid nitrile rubber Internal EEx e brass clamps on base Through 7mm holes moulded into base ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard The entry is fitted with a 20mm EEx e cable gland as standard 25mm entries are available as an option 1x20mm EEx e threaded hole base at A as standard. The entry is fitted with a 20mm EEx e cable gland as standard. 25mm entries are available as an option. ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Walsall EEx de IIC switch. Certification No. SIRA 03ATEX1269U. Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U Operating Voltage Volts 230-270 Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting EEx de IIC Operating Current Amps 16 Voltage Volts 230-270 Conductor Size mmsq. Max 2.5 Current Amps 16 Conductor Size mmsq. Max 2.5 All Dimensions in mm ORDERING INFORMATION All Dimensions in mm Engage - Engage 20º 90º Engage - Engage - Engage 20º 90º 160º Action Contacts Labelling 3 Position Switch with centre off Product Code 3 Position Switch with centre off 8 1 Red Mushroom Pushbutton Action 3 Position Switch with centre off ORDERING INFORMATION Description Description 2 Position Switch Emergency stop Pull release LCP131 5 4 3 Position Control Switch Contacts Engage - Engage - Spring 20º 90º 160º Spring - Engage - Spring 20º 90º 160º Spring - Engage - Spring 20º 90º 160º Spring - Engage - Spring 20º 90º 160º 8 1 Red Mushroom Pushbutton Emergency stop Key release LCP132 3 Position Control Switch 5 4 Note For 25 mm entries add/25 to Product Code e.g. LCP132/25 3 Position Control Switch Notes 1 2 3 93 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Spring - Engage - Spring 20º 90º 160º 1-3 2-4 5-7 6-8 Labelling 0 - Product Code I LCP141 I - 0 - II LCP142 I - 0 - II LCP143 I - 0 - II LCP144 I - 0 - II LCP145 I - 0 - II LCP146 I - 0 - II LCP147 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 For 25 mm entries add/25 to Product Code e.g. LCP141/25 Alternative labelling to order. Add “K” to 2 position switch for key lock version. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 94 Local Control Station - Glass Reinforced Polyester Enclosure Type LCP150 - EEx em LED Indicator lamp EEx em IIC Zones 1,2,21,22 T6 Group II Cat 2 Local Control Station - Glass Reinforced Polyester Enclosure Type LCP160 - EEx e Ammeter ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION II 2 G EEx em IIC T6 -40˚C to + 50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting EEx e II II 2 GD EEx e II T6 -40˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION 110mm x 110mm x 113mm Carbon loaded anti-static Glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 allen head stainless steel screws 1.2mm one piece solid nitrile rubber Internal EEx e brass clamps on base Through 7mm holes moulded into base Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting ENTRY SPECIFICATION 110mm x 110mm x 99mm Carbon loaded anti-static Glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 allen head stainless steel screws 1.2 mm one piece solid nitrile rubber Internal EEx e brass clamps on base Through 7mm holes moulded into base ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard The entry is fitted with a 20mm EEx e cable gland as standard 25mm entries are available as an option 1x20mm EEx e threaded hole base at A as standard. The entry is fitted with a 20mm EEx e cable gland as standard. 25mm entries are available as an option. ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Walsall EEx em IIC indicator lamp. Certification No. SIRA 04ATEX5056U Voltage AC and DC Volts (AC-5% +10%) 24 - 240 Current Amps 0.005 Walsall EEx e II ammeter. Certification No. SIRA 02ATEX3380U. Conductor Size mmsq. Max 2.5 Voltage Volts 240 All Dimensions in mm Direct Operated 0 - 2 - 12 amps 0 - 5 - 30 amps 0 - 10 - 60 amps Current Amps 16 Conductor Size mmsq. Max 2.5 Standard Meter Scales Operated from current transformer with 1 amp secondary 0 - 60 - 360 amps 0 - 10 - 60 amps 0 - 80 - 480 amps 0 - 15 - 90 amps 0 - 100 - 600 amps 0 - 20 - 120 amps 0 - 150 - 900 amps 0 - 30 - 180 amps 0 - 200 - 1200 amps 0 - 40 - 240 amps 0 - 50 - 300 amps All Dimensions in mm ORDERING INFORMATION Description Green Indicator Lamp Red Indicator Lamp Amber Indicator Lamp Clear Indicator Lamp Blue Indicator Lamp Product Code LCP151 LCP152 LCP153 LCP154 LCP155 ORDERING INFORMATION Description Ammeter Note For 25 mm entries add/25 to Product Code e.g. LCP160/25 Scale To Be Specified Product Code LCP160 Note For 25 mm entries add/25 to Product Code e.g. LCP151/25 95 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 96 Local Control Station - Glass Reinforced Polyester Enclosure Type LCP170 - EEx de Double Green and Red Pushbuttons EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 Local Control Station - Glass Reinforced Polyester Enclosure Type LCP180 - EEx de Double Green and Mushroom Red Pushbuttons ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx de IIC T6 -40˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection T6 Group II Cat 2 ATEX/GOST II 2 GD EEx de IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION 110mm x 110mm x 113mm Carbon loaded anti-static Glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 allen head stainless steel screws 1.2mm one piece solid nitrile rubber Internal EEx e brass clamps on base Through 7mm holes moulded into base Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting ENTRY SPECIFICATION 110mm x 110mm x 121mm Carbon loaded anti-static Glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 allen head stainless steel screws 1.2mm one piece solid nitrile rubber Internal EEx e brass clamps on base Through 7mm holes moulded into base ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard The entry is fitted with a 20mm EEx e cable gland as standard 25mm entries are available as an option 1x20mm EEx e threaded hole base at A as standard. The entry is fitted with a 20mm EEx e cable gland as standard. 25mm entries are available as an option. ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U Voltage Volts 240 Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting EEx de IIC Current AC21A(A) 16 Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U. Conductor Size mmsq. Max 2.5 Voltage Volts 230-270 Current AC21A(A) 16 Conductor Size mmsq. Max 2.5 All Dimensions in mm All Dimensions in mm ORDERING INFORMATION Description Action Contacts 8 Green Pushbutton Spring 5 ORDERING INFORMATION Description Action 8 Contacts Description Action 8 Green Pushbutton Red Pushbutton Spring 5 Notes 1 2 3 97 Contact labelling Product Code 1 0 - I LCP171 4 Stop - Start LCP172 Spring For 25 mm entries add/25 to Product Code e.g. LCP171/25 Alternative labelling to order. Alternative button colours to order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Green Pushbutton Spring 5 8 Green Pushbutton Spring 5 Notes 1 2 3 Description Red Mushroom Pushbutton Red Mushroom Pushbutton Red Mushroom Pushbutton Action Contact 1 Spring 4 1 Pull Release 4 1 Key Ralease 4 labelling Product Code 0 - I LCP181 Stop - Start LCP182 0 - I LCP183 Stop - Start LCP184 0 - I LCP185 Stop - Start LCP186 For 25 mm entries add/25 to Product Code e.g. LCP181/25 Alternative labelling to order. Alternative button colours to order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 98 Customised Local Control Stations - Glass Reinforced Polyester Enclosure Type LCP200 - EEx edm Two Function Customised Control Stations EEx edm IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx e, ed, em IIC T6 -40˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA03ATEX3293. POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Dimensions Material Finish Weight Cover fixing Gasket Security Base II 2 GD EEx e, ed, em IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA03ATEX3293. POCC. GB. гБ 05.BO1132 IP66 to EN60529:1991 CONTROL FUNCTIONS As listed on pages 83 to 88 As listed on pages 83 to 88 ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION 230 – 270 Volts 16 Amps max 2.5mm sq. max Operating Voltage Operating Current Terminal Capacity ORDERING INFORMATION 230 – 270 Volts 16 Amps max 2.5mm sq. max ORDERING INFORMATION The first function specified in the order code occupies position X in the enclosure and the second function position Y. The first function specified in the order code occupies position X in the enclosure, the second function Y and the third function position Z. Ordering codes are built up as shown in the following examples. Ordering codes are built up as shown in the following examples. Example 1 Ammeter plus 2 pole changeover switch. Example 1 Emergency stop with pull release plus green start plus green indicator lamp Product Code: LCP200 + CF37 + CF2 Product Code: LCP300 + CF26 + CF11 + CF34 Example 2 On/Off switch plus green indicator lamp. Example 2 Double green and red pushbutton plus red indicator plus mushroom pushbutton. Product Code: LCP200 + CF1 + CF34 1. Labelling to be specified by customer. 2. For 25mm entries add /25 to enclosure code e.g. LCP200/25 + CF37 + CF2 Product Code: LCP300 + CF32 + CF33+ CF17 1. Labelling to be specified by customer. 2. For 25mm entries add /25 to enclosure code e.g. LCP300/25 + CF26 + CF11 + CF34 ENCLOSURE INTERCONNECTIONS 1,2 and 3 function local control stations can be connected together to engineer more complex systems. The interconnection is made via a specially approved gland manufactured by Walsall Ltd. ENCLOSURE INTERCONNECTIONS All Dimensions in mm 99 ATEX/GOST 1x20mm EEx e threaded hole base at A as standard. The entry is fitted with a 20mm EEx e cable gland as standard. 25mm entries are available as an option. 3 x entries maximum as required by control functions specified. Cover CONTROL FUNCTIONS Operating Voltage Operating Current Terminal Capacity Group II Cat 1,2,3 ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard The entry is fitted with a 20mm EEx e cable gland as standard 25mm entries are available as an option 2 x entries maximum as required by control functions specified Cover T6 220mm x 110mm Carbon loaded anti-static Glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 allen head stainless steel screws 1.2 mm one piece solid nitrile rubber Switches with an off position have a padlock ‘off’ ‘facility as standard Internal EEx e brass clamps on base Through 7mm holes moulded into base Earthing Mounting ENTRY SPECIFICATION Base Zones 1,2,21,22 ENCLOSURE SPECIFICATION 220mm x 110mm Carbon loaded anti-static Glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 allen head stainless steel screws 1.2mm one piece solid nitrile rubber Switches with an off position have a padlock ‘off’ ‘facility as standard Internal EEx e brass clamps on base Through 7mm holes moulded into base Earthing Mounting EEx edm IIC HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Security Customised Local Control Stations - Glass Reinforced Polyester Enclosure Type LCP300 - EEx edm Three Function Customised Control Stations tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 1,2 and 3 function local control stations can be connected together to engineer more complex systems. The interconnection is made via a specially approved gland manufactured by Walsall Ltd. All Dimensions in mm tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 100 Local Control Station - Stainless Steel Enclosure Type LCS100 - EEx de 16 amp General Purpose Switch PART 2.3 LCS RANGE EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Standard and Customised EEx edm Local Control Stations in Stainless Steel Enclosures.The LCS Range offers very robust local control stations in fabricated stainless steel enclosures. All the actuators are metal clad with nickel plated brass housings. Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx de II C T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC. SIRA99ATEX3199 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Standard Control Stations Type LCS100 – 16amp General Purpose Switch Page 102 Type LCS110 – Pushbutton Page 103 Type LCS120 – Mushroom Pushbutton Page 104 Type LCS130 – Emergency Pushbutton Page 105 Type LCS140 – Position and Control Switch Page 106 Type LCS150 – LED Indicator Lamp Page 107 Type LCS160 – Ammeter Page 108 ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting 110mm x 110mm x 152mm 1.5mm 316L, (1.4404) stainless Stainless steel – electropolished 1.2Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance Customised Control Stations Type LCS200 – 2 Function Customised Control Stations Page 109 Type LCS300 – 3 Function Customised Control Stations Page 110 ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard. The entry is fitted with a 20mm EEx e cable gland as standard. 25mm entries are available as an option. ELECTRICAL SPECIFICATION Walsall EEx de IIC switch. Certification No. SIRA 03ATEX1269U Operating Voltage Volts 230-270 Operating Current AC21A(A) 16 Conductor Size mmsq. Max 2.5 All Dimensions in mm ORDERING INFORMATION Description Double pole off/on Double pole changeover Single pole changeover Notes 1 2 101 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Action Engage- Engage Engage- Engage Engage- Engage- Engage 20º 90º 20º 90º 20º 90º 160º Contacts Labelling 1-3 2-4 5-7 6-8 0 - I Off - On 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 Product Code LCS101 LCS102 I - II LCS103 I - 2 LCS104 I - 0 - II LCS105 I -0- 2 LCS106 For 25 mm entries add/25 to Product Code e.g. LCS103/25 Alternative labelling to order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 102 Local Control Station - Stainless Steel Enclosure Type LCS110 - EEx de Pushbutton EEx de IIC Zones 1,2,21,22 T6 Local Control Station - Stainless Steel Enclosure Type LCS120 - EEx de Mushroom Pushbutton Group II Cat 2 ATEX/GOST II 2 GD EEx de IIC T6 -40˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA99ATEX3199 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting T6 Group II Cat 2 ATEX/GOST II 2 GD EEx de IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA99ATEX3199 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION 110mm x 110mm x 139mm 1.5mm 316L, (1.4404) stainless Stainless steel – electropolished 1.2Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting ENTRY SPECIFICATION 110mm x 110mm x 146mm 1.5mm 316L, (1.4404) stainless Stainless steel – electropolished 1.2Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard The entry is fitted with a 20mm EEx e cable gland as standard 25mm entries are available as an option 1x20mm EEx e threaded hole base at A as standard. The entry is fitted with a 20mm EEx e cable gland as standard. 25mm entries are available as an option. ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U Operating Voltage Volts 230-270 Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection EEx de IIC Operating Current AC21A(A) 16 Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U. Operating Voltage Volts 230-270 Conductor Size mmsq. Max 2.5 Operating Current AC21A(A) 16 Conductor Size mmsq. Max 2.5 All Dimensions in mm All Dimensions in mm ORDERING INFORMATION ORDERING INFORMATION Description Green Pushbutton Description Action Contacts 8 1 8 1 103 0 LCS111 start I LCS112 Red Mushroom Pushbutton Action stop Red Mushroom Pushbutton LCS114 For 25 mm entries add/25 to Product Code e.g. LCS112/25 Alternative labelling to order Alternative button colours to order tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Red Mushroom Pushbutton Notes 1 2 3 Contacts Labelling Product Code 8 1 I LCS121 5 4 Stop LCS122 8 1 I LCS123 5 4 Stop LCS124 8 1 I LCS125 5 4 Stop LCS126 Spring Pull release LCS113 Spring 5 4 Notes 1 2 3 Product Code Spring 5 4 Red Pushbutton Labelling Key release For 25 mm entries add/25 to Product Code e.g. LCS121/25 Alternative labelling to order. Alternative button colours to order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 104 Local Control Station - Stainless Steel Enclosure Type LCS130 - EEx de Emergency Pushbutton EEx de IIC Zones 1,2,21,22 T6 Local Control Station - Stainless Steel Enclosure Type LCS140 - EEx de Position and Control Switch Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION II 2 GD EEx de IIC T6 -40˚C to + 50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA99ATEX3199 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection II 2 GD EEx de IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA99ATEX3199 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing 110mm x 110mm x 146mm 1.5mm 316L, (1.4404) stainless Stainless steel – electropolish 1.2Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance Entries External Mounting 110mm x 110mm x 148`mm 1.5mm 316L, (1.4404) stainless Stainless steel – electropolished 1.2Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard. The entry is fitted with a 20mm EEx e cable gland as standard. 25mm entries are available as an option. ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard The entry is fitted with a 20mm EEx e cable gland as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION Walsall EEx de IIC switch. Certification No. SIRA 03ATEX1269U. ELECTRICAL SPECIFICATION Voltage Volts 230-270 Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U Current AC21A(A) 16 Conductor Size mmsq. Max 2.5 All Dimensions in mm Operating Voltage Volts 230-270 Operating Current AC21A(A) 16 Conductor Size mmsq. Max 2.5 ORDERING INFORMATION All Dimensions in mm Engage - Engage 20º 90º Engage - Engage - Engage 20º 90º 160º Action Contacts Labelling 3 Position Switch with centre off Product Code 3 Position Switch with centre off 8 1 Red Mushroom Pushbutton Action 3 Position Switch with centre off ORDERING INFORMATION Description Description 2 Position Switch Emergency stop Pull release LCS131 5 4 3 Position Control Switch Contacts Engage - Engage - Spring 20º 90º 160º Spring - Engage - Spring 20º 90º 160º Spring - Engage - Spring 20º 90º 160º Spring - Engage - Spring 20º 90º 160º 8 1 Red Mushroom Pushbutton Emergency stop Key release LCS132 3 Position Control Switch 5 4 Note For 25 mm entries add/25 to Product Code e.g. LCS131/25 3 Position Control Switch Notes 1 2 3 4 105 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Spring - Engage - Spring 20º 90º 160º 1-3 2-4 5-7 6-8 Labelling 0 - Product Code I LCS141 I - 0 - II LCS142 I - 0 - II LCS143 I - 0 - II LCS144 I - 0 - II LCS145 I - 0 - II LCS146 I - 0 - II LCS147 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 For 25 mm entries add/25 to Product Code e.g. LCS141/25 Alternative labelling to order. Alternative handle colours to order. Add “K” to 2 position switch for key lock version. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 106 Local Control Station - Stainless Steel Enclosure Type LCS150 - EEx em LED Indicator lamp EEx em IIC Zones 1,2,21,22 T6 Local Control Station - Stainless Steel Enclosure Type LCS160 - EEx e Ammeter Group II Cat 2 ATEX/GOST II 2 G EEx em IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA99ATEX3199 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting T6 Group II Cat 2 ATEX/GOST II 2 GD EEx e II T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA99ATEX3199 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION 110mm x 110mm x 137mm 1.5mm 316L, (1.4404) stainless Stainless steel – electropolished 1.2Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting 110mm x 110mm x 133mm 1.5mm 316L, (1.4404) stainless Stainless steel – electropolished 1.2Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 6mm brass internal/external earth stud as standard Optional brass earth stud welded to cover Direct through body External lugs with 8mm clearance ENTRY SPECIFICATION ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard. The entry is fitted with a 20mm EEx e cable gland as standard. 25mm entries are available as an option. 1x20mm EEx e threaded hole base at A as standard The entry is fitted with a 20mm EEx e cable gland as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Walsall EEx e II ammeter Certification No. SIRA 02ATEX3380U. Walsall EEx em IIC indicator lamp. Certification No. SIRA 04ATEX5056U Voltage AC and DC Volts (AC-5%+10%) 24 - 230 Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection EEx e II Current AC21A(A) 0.005 Conductor Size mmsq. Max 2.5 Voltage Volts 240 All Dimensions in mm Direct Operated 0 - 2 - 12 amps 0 - 5 - 30 amps 0 - 10 - 60 amps Current AC21A(A) 16 Conductor Size mmsq. Max 2.5 Standard Meter Scales Operated from current transformer with 1 amp secondary 0 - 60 - 360 amps 0 - 10 - 60 amps 0 - 80 - 480 amps 0 - 15 - 90 amps 0 - 100 - 600 amps 0 - 20 - 120 amps 0 - 150 - 900 amps 0 - 30 - 180 amps 0 - 200 - 1200 amps 0 - 40 - 240 amps 0 - 50 - 300 amps All Dimensions in mm ORDERING INFORMATION Notes 1 107 Description Green Indicator Lamp Red Indicator Lamp Amber Indicator Lamp Clear Indicator Lamp Blue Indicator Lamp For 25 mm entries add/25 to Product Code e.g. LCS151/25 Product Code LCS151 LCS152 LCS153 LCS154 LCS155 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com ORDERING INFORMATION Note 1 Current Rating Ammeter For 25 mm entries add/25 to Product Code e.g. LCS160/25 Scale To Be Specified tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code LCS160 108 Customised Local Control Stations - Stainless Steel Enclosure Type LCS200 - EEx edm Two Function Customised Control Stations EEx edm IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection External Mounting Internal Mounting II 2 GD EEx e, ed, em IIC T6 -40˚C to + 50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA03ATEX3293. POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection 165mm x 110mm 1.5mm 316L, (1.4404) stainless or mild steel Stainless steel – electropolished 1.2Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 10mm brass internal/external earth stud as standard Optional brass earth stud welded to cover External lugs with 10mm clearance Optional mounting plate to suit Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing External Mounting Internal Mounting Base 230mm x 110mm 1.5mm 316L, (1.4404) stainless or mild steel Stainless steel – electropolished 1.2Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 10mm brass internal/external earth stud as standard Optional brass earth stud welded to cover External lugs with 10mm clearance Optional mounting plate to suit ELECTRICAL SPECIFICATION 230 – 270 Volts 16 Amps max 2.5mm sq. max Operating Voltage Operating Current Terminal Capacity ORDERING INFORMATION 230 – 270 Volts 16 Amps max 2.5mm sq. max ORDERING INFORMATION The first function specified in the order code occupies position X in the enclosure and the second function position Y. The first function specified in the order code occupies position X in the enclosure, the second function Y and the third function position Z. Ordering codes are built up as shown in the following examples. Ordering codes are built up as shown in the following examples. Ammeter plus 2 pole changeover switch. Example 1 Emergency stop with pull release plus green start plus green indicator lamp Product Code: LCS200 + CF12 + CF7 Product Code: LCS300 + CF12 + CF7 + CF35 On/Off switch plus green indicator lamp. Example 2 Double green and red pushbutton plus red indicator plus mushroom pushbutton. Product Code: LCS200 + CF25 1. Labelling to be specified by customer. 2. For 25mm entries add /25 to enclosure code e.g. LCS200/25 + CF12 + CF7 Product Code: LCS300 + CF25 + CF31+ CF10 1. Labelling to be specified by customer. 2. For 25mm entries add /25 to enclosure code e.g. LCS300/25 + CF12 + CF7 + CF35 ENCLOSURE INTERCONNECTIONS 1,2 and 3 function local control stations can be connected together to engineer more complex systems. The interconnection is made via a specially approved gland manufactured by Walsall Ltd. ENCLOSURE INTERCONNECTIONS All Dimensions in mm 109 II 2 GD EEx e, ed, em IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA03ATEX3293. POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 As listed on pages 83 - 88 ELECTRICAL SPECIFICATION Example 2 ATEX/GOST CONTROL FUNCTIONS As listed on pages 83 - 88 Example 1 Group II Cat 2 1x20mm EEx e threaded hole base at A and B as standard All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option 3 x entries maximum as required by control functions specified Cover CONTROL FUNCTIONS Operating Voltage Operating Current Terminal Capacity T6 ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard The entry is fitted with a 20mm EEx e cable gland as standard 25mm entries are available as an option 2 x entries maximum as required by control functions specified Cover Zones 1,2,21,22 ENCLOSURE SPECIFICATION ENTRY SPECIFICATION Base EEx edm IIC HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Customised Local Control Stations - Stainless Steel Enclosure Type LCS300 - EEx edm Three Function Cutomised Control Stations tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 1,2 and 3 function local control stations can be connected together to engineer more complex systems. The interconnection is made via a specially approved gland manufactured by Walsall Ltd. All Dimensions in mm tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 110 Local Control Station - Aluminium Enclosure Type LCA100 - EEx de 16 amp General Purpose Switch PART 2.4 LCA RANGE EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Standard and Customised EEx edm Local Control Stations in Aluminium Enclosures.The LCS Range offers very robust local control stations in fabricated Aluminium enclosures. All the actuators are metal clad with nickel plated brass housings. Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx de II C T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Standard Control Stations Type LCA100 – 16amp General Purpose Switch Page 112 Type LCA110 – Pushbutton Page 113 Type LCA120 – Mushroom Pushbutton Page 114 Type LCA130 – Emergency Pushbutton Page 115 Type LCA140 – Position and Control Switch Page 116 Type LCA150 – LED Indicator Lamp Page 117 Type LCA160 – Ammeter Page 118 ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting Internal Mounting 110mm x 110mm x 152mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 0.4Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body External lugs with 8mm clearance Optional mounting plate to suit Customised Control Stations Type LCA200 – 2 Function Customised Control Stations Page 119 ENTRY SPECIFICATION Type LCA300 – 3 Function Customised Control Stations Page 120 1x20mm EEx e threaded hole base at A as standard. All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION Walsall EEx de IIC switch. Certification No. SIRA 03ATEX1269U Operating Voltage Volts 230-270 Operating Current AC21A(A) 16 Conductor Size mmsq. Max 2.5 All Dimensions in mm ORDERING INFORMATION Description Double pole off/on Double pole changeover Single pole changeover Notes 1 2 111 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Action Engage- Engage Engage- Engage Engage- Engage- Engage 20º 90º 20º 90º 20º 90º 160º Contacts Labelling 1-3 2-4 5-7 6-8 0 - I Off - On 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 Product Code LCA101 LCA102 I - II LCA103 I - 2 LCA104 I - 0 - II LCA105 I -0- 2 LCA106 For 25 mm entries add/25 to Product Code e.g. LCA103/25 Alternative labelling to order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 112 Local Control Station - Aluminium Enclosure Type LCA110 - EEx de Pushbutton EEx de IIC Zones 1,2,21,22 T6 Local Control Station - Aluminium Enclosure Type LCA120 - EEx de Mushroom Pushbutton Group II Cat 2 ATEX/GOST II 2 GD EEx de II T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA99ATEX3199 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting Internal Mounting T6 Group II Cat 2 ATEX/GOST II 2 GD EEx de II T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION 110mm x 110mm x 139mm 1.5mm Aluminium 1050A, H14 Powder coated RAL 7032 0.4Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body External lugs with 8mm clearance Optional mounting plate to suit Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting Internal Mounting 110mm x 110mm x 146mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 0.4Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body External lugs with 8mm clearance Optional mounting plate to suit ENTRY SPECIFICATION ENTRY SPECIFICATION 1x20mm EEx e hole at A as standard. All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option 1x20mm EEx e hole at A as standard All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U. Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U Operating Voltage Volts 230-270 Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection EEx de IIC Operating Current AC21A(A) 16 Conductor Size mmsq. Max 2.5 Operating Voltage Volts 230-270 Operating Current AC21A(A) 16 Conductor Size mmsq. Max 2.5 All Dimensions in mm All Dimensions in mm ORDERING INFORMATION ORDERING INFORMATION Description Green Pushbutton Description Action Contacts 8 1 8 1 113 0 LCA111 start I LCA112 Red Mushroom Pushbutton Action stop Red Mushroom Pushbutton LCA114 For 25 mm entries add/25 to Product Code e.g. LCA111/25 Alternative labelling to order. Alternative button colours to order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Red Mushroom Pushbutton Notes 1 2 3 Contacts Labelling Product Code 8 1 I LCA121 5 4 Stop LCA122 8 1 I LCA123 5 4 Stop LCA124 8 1 I LCA125 5 4 Stop LCA126 Spring Pull release LCA113 Spring 5 4 Notes 1 2 3 Product Code Spring 5 4 Red Pushbutton Labelling Key release For 25 mm entries add/25 to Product Code e.g. LCA121/25 Alternative labelling to order. Alternative button colours to order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 114 Local Control Station - Aluminium Enclosure Type LCA130 - EEx de Emergency Pushbutton EEx de IIC Zones 1,2,21,22 T6 Local Control Station - Aluminium Enclosure Type LCA140 - EEx de Position and Control Switch Group II Cat 2 ATEX/GOST Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Apparatus standard Certification No Ingress protection EEx de IIC II 2 GD EEx de II T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC EN 50014:1998 and EN 50019: 1995 SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection II 2 GD EEx de II T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting Internal Mounting Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing 110mm x 110mm x 146mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 0.4Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body External lugs with 8mm clearance Optional mounting plate to suit Entries External Mounting Internal Mounting 110mm x 110mm x 148mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 0.4Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body External lugs with 8mm clearance Optional mounting plate to suit ENTRY SPECIFICATION 1x20mm EEx e hole at A as standard. All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option ENTRY SPECIFICATION 1x20mm EEx e hole at A as standard All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION Walsall EEx de IIC switch. Certification No. SIRA 03ATEX1269U. Voltage Volts 230-270 ELECTRICAL SPECIFICATION Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U Operating Voltage Volts 230-270 Operating Current AC21A(A) 16 All Dimensions in mm Action Engage - Engage 20º 90º Engage - Engage - Engage 20º 90º 160º Contacts Labelling Product Code 3 Position Switch with centre off LCA131 3 Position Switch with centre off 8 1 Red Mushroom Pushbutton Description 2 Position Switch 3 Position Switch with centre off Action Emergency stop Pull release 3 Position Control Switch 20º 90º 160º Spring - Engage - Spring 20º 90º 160º Spring - Engage - Spring 20º 90º 160º Spring - Engage - Spring 20º 90º 160º 8 1 Emergency stop Key release LCA132 5 4 Note For 25 mm entries add/25 to Product Code e.g. LCA131/25 3 Position Control Switch 3 Position Control Switch Notes 1 2 3 4 115 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Contacts Engage - Engage - Spring 5 4 Red Mushroom Pushbutton Conductor Size mmsq. Max 2.5 All Dimensions in mm ORDERING INFORMATION Conductor Size mmsq. Max 2.5 ORDERING INFORMATION Description Current AC21A(A) 16 Spring - Engage - Spring 20º 90º 160º 1-3 2-4 5-7 6-8 Labelling 0 - Product Code I LCA141 I - 0 - II LCA142 I - 0 - II LCA143 I - 0 - II LCA144 I - 0 - II LCA145 I - 0 - II LCA146 I - 0 - II LCA147 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 1-3 2-4 5-7 6-8 For 25 mm entries add/25 to Product Code e.g. LCA141/25 Alternative labelling to order. Alternative handle colours to order. Add “K” to 2 position switch for key lock version. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 116 Local Control Station - Aluminium Enclosure Type LCA150 - EEx em LED Indicator lamp EEx em IIC Zones 1,2,21,22 T6 Local Control Station - Aluminium Enclosure Type LCA160 - EEx e Ammeter Group II Cat 2 ATEX/GOST II 2 G EEx em II T6 -40˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting Internal Mounting Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection EEx de IIC II 2 GD EEx de II T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION 110mm x 110mm x 137mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 0.4Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body External lugs with 8mm clearance Optional mounting plate to suit Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Entries External Mounting Internal Mounting 110mm x 110mm x 133mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 0.4Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Direct through body External lugs with 8mm clearance Optional mounting plate to suit ENTRY SPECIFICATION ENTRY SPECIFICATION 1x20mm EEx e hole at A as standard. All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option 1x20mm EEx e hole at A as standard All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Walsall EEx e II ammeter. Certification No. SIRA 02ATEX3380U. Walsall EEx em IIC indicator lamp. Certification No. SIRA 04ATEX5056U Voltage AC and DC Volts (AC-5%+10%) 24 - 230 Current AC21A(A) 0.005 Conductor Size mmsq. Max 2.5 Voltage Volts 240 Current AC21A(A) 16 Conductor Size mmsq. Max 2.5 All Dimensions in mm All Dimensions in mm Direct Operated 0 - 2 - 12 amps 0 - 5 - 30 amps 0 - 10 - 60 amps Standard Meter Scales Operated from current transformer with 1 amp secondary 0 - 60 - 360 amps 0 - 10 - 60 amps 0 - 80 - 480 amps 0 - 15 - 90 amps 0 - 100 - 600 amps 0 - 20 - 120 amps 0 - 150 - 900 amps 0 - 30 - 180 amps 0 - 200 - 1200 amps 0 - 40 - 240 amps 0 - 50 - 300 amps ORDERING INFORMATION Description Green Indicator Lamp Red Indicator Lamp Amber Indicator Lamp Clear Indicator Lamp Blue Indicator Lamp Notes 117 Product Code LCA151 LCA152 LCA153 LCA154 LCA155 ORDERING INFORMATION Note 1 Current Rating Ammeter For 25 mm entries add/25 to Product Code e.g. LCA160/25 Scale To Be Specified Product Code LCA160 For 25 mm entries add/25 to Product Code e.g. LCS151/25 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 118 Customised Local Control Stations - Aluminium Enclosure Type LCA200 - EEx edm Two Function Customised Control Stations EEx edm IIC Zones 1,2,21,22 T6 Group II Cat 1,2,3 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection External Mounting Internal Mounting EEx edm IIC Zones 1,2,21,22 T6 Group II Cat 1,2,3 ATEX/GOST HAZARDOUS AREA SPECIFICATION II 2 GD EEx e, ed, em IIC T6 -40˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA03ATEX3293. POCC. GB. гБ 05.BO1132 IP66 to EN60529:1991 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection ENCLOSURE SPECIFICATION Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing Customised Local Control Stations - Aluminium Enclosure Type LCA300 - EEx edm Three Function Customised Control Stations II 2 GD EEx e, ed, em IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA03ATEX3293. POCC. GB. гБ 05.BO1132 IP66 to EN60529:1991 GVU2 ENCLOSURE SPECIFICATION 165mm x 110mm 3mm Aluminium 1050A, H14 Powder coated RAL 7032 0.4Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover External lugs with 10mm clearance Optional mounting plate to suit Dimensions Material box Finish Weight empty Cover fixing Gasket Earthing External Mounting Internal Mounting 230mm x 110mm 3.0mm Aluminium 1050A, H14 Powder coated RAL 7032 0.4Kg Captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover External lugs with 10mm clearance Optional mounting plate to suit ENTRY SPECIFICATION ENTRY SPECIFICATION Base Base 1x20mm EEx e hole at A and B as standard All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option 2 x entries maximum as required by control functions specified Cover 1x20mm EEx e hole at A and B as standard All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option 3 x entries maximum as required by control functions specified Cover CONTROL FUNCTIONS CONTROL FUNCTIONS As listed on pages 83 -88 As listed on pages 83 -88 ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Operating Voltage Operating Current Terminal Capacity Operating Voltage Operating Current Terminal Capacity 230 – 270 Volts 16 Amps max 2.5mm sq. max 230 – 270 Volts 16 Amps max 2.5mm sq. max ORDERING INFORMATION ORDERING INFORMATION The first function specified in the order code occupies position X in the enclosure, the second function Y and the third function position Z. The first function specified in the order code occupies position X in the enclosure and the second function position Y. Ordering codes are built up as shown in the following examples. Ordering codes are built up as shown in the following examples. Ex 1 Ex 1 Ammeter plus 2 pole changeover switch. Product Code: LCA200 + CF12 + CF7 Ex 2 Emergency stop with pull release plus green start plus green indicator lamp Product Code: LCA300 + CF12 + CF7 + CF35 Ex 2 On/Off switch plus green indicator lamp. Double green and red pushbutton plus red indicator plus mushroom pushbutton. Product Code: LCA300 + CF25 + CF31+ CF10 Product Code: LCA200 + CF25 1. Labelling to be specified by customer. 2. For 25mm entries add /25 to enclosure code e.g. LCA200/25 + CF12 + CF7 1. Labelling to be specified by customer. 2. For 25mm entries add /25 to enclosure code e.g. LCA300/25 + CF12 + CF7 + CF35 ENCLOSURE INTERCONNECTIONS 1,2 and 3 function local control stations can be connected together to engineer more complex systems. The interconnection is made via a specially approved gland manufactured by Walsall Ltd. 119 ENCLOSURE INTERCONNECTIONS All Dimensions in mm tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 1,2 and 3 function local control stations can be connected together to engineer more complex systems. The interconnection is made via a specially approved gland manufactured by Walsall Ltd. All Dimensions in mm tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 120 Local Control Station - Glass Reinforced Polyester Enclosure Type GVU/E030 - EEx de Single Pushbutton PART 2.5 GVU RANGE EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION EEx ed Heavy Duty Local Control Stations in Glass Reinforced Polyester Enclosures. The GVU Range offers very robust local control stations. The minimum wall thickness of the enclosures is 6mm and all the actuators are shrouded in Heavy Duty GRP. Type GVU/E030 – Single Pushbutton Page 122 Type GVU/E030 – Double Pushbutton Page 123 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection II 2 GD EEx de IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting 110mm x 110mm x 115mm Carbon loaded Glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 pan head stainless steel screws 1.2 mm one piece solid nitrile rubber Internal EEx e brass clamps on base Through 7mm holes fixing strap ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard. The entry is fitted with a 20mm EEx e cable gland as standard. 25mm entries are available as an option. ELECTRICAL SPECIFICATION Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U Operating Voltage Volts 230-270 Operating Current Amps 16 Conductor Size mmsq. Max 2.5 All Dimensions in mm ORDERING INFORMATION Description Shrouded green pushbutton Shrouded red pushbutton Shrouded red pushbutton with stayput Exposed red pushbutton Mushroom pushbutton with stayput Notes 1 2 3 121 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Labelling Start Stop Stop Stop Emergency Stop Product Code E030160 E030161 E030162 E030163 E030164 For 25 mm entries add/25 to Product Code e.g. E030160/25 Alternative labelling to order. Alternative button colours to order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 122 Local Control Station - Glass Reinforced Polyester Enclosure Type GVU/E030 - EEx de Double Pushbutton EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No Ingress protection II 2 GD EEx de IIC T6 -40˚C to + 50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA03ATEX3293 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting 110mm x 110mm x 113mm Carbon loaded Glass reinforced polyester UL94/V0 Moulded black 1.2 Kg M6 pan head stainless steel screws 1.2mm one piece solid nitrile rubber Internal EEx e brass clamps on base Through 7mm holes fixing strap ENTRY SPECIFICATION 1x20mm EEx e threaded hole base at A as standard. The entry is fitted with a 20mm EEx e cable gland as standard. 25mm entries are available as an option. ELECTRICAL SPECIFICATION Walsall EEx de IIC contact block. Certification No. SIRA 03ATEX1269U Operating Voltage Volts 230-270 Operating Current Amps 16 Conductor Size mmsq. Max 2.5 CNC machining of GRP enclosures All Dimensions in mm ORDERING INFORMATION Description Shrouded green and shrouded red Shrouded green and shrouded red with stayput Shrouded green and exposed red with stayput Shrouded green and mushroom red with stayput Notes 1 2 3 123 Labelling Start/Stop Start/Stop Start/Stop Start/Stop Product Code E030165 E030166 E030167 E030168A For 25 mm entries add/25 to Product Code e.g. E030165/25 Alternative labelling to order. Alternative button colours to order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com CNC compression moulding of GRP enclosures tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 124 Customised Control Panels - Glass Reinforced Polyester Enclosure Type GLCP - EEx edm Control Panel PART 2.6 GLCP RANGE EEx edm IIC Zones 1,2,21,22 T6, T5 Group II Cat 2 ATEX/GOST The EEx edm approved control functions listed on pages 83-88 can be installed in EEx e approved enclosures moulded from glass reinforced polyester to engineer a wide range of customised EEx edm approved control panels. EEx edm IIC customised control panels in glass reinforced poyester enclosures. Type GLCP11 – 255mm x 250mm x 120mm Page 126 Type GLCP12 – 400mm x 250mm x 120mm Page 126 Type GLCP13 – 405mm x 400mm x 120mm Page 126 Type GLCP14 – 405mm x 400mm x 165mm Page 126 CUSTOMISING As a vertically integrated manufacturer Walsall can customise the GLCP range at each stage of the manufacturing process to meet individual customer requirements. HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Certification No. Ingress protection II 2 GD EEx e de em IIC T6 -40˚C to +40˚C, 50˚C SIRA99ATEX3200 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Type GLCP11 255mm x 250mm x 120mm Type GLCP12 400mm x 250mm x 120mm Type GLCP13 405mm x 400mm x 120mm Type GLCP14 405mm x 400mm x 165mm Carbon loaded, anti-static glass reinforced polyester UL 94/V0 Moulded self colour black. Other colours available on request Captive M6 stainless steel allen head screws. Optional hinges Silicon rubber Optional 6mm brass internal/external earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through threaded hole in body Integral 6.5mm clearance holes moulded into the body Material Finish Cover fixing Gasket Earthing Entry Mounting Drawing shows typical enclosure e.g GLCP13 ENTRY SPECIFICATION Entries are to customer requirements. The table below gives a guide to the gland capacity for the more commonly used gland sizes. For other gland sizes or mixed sizes consult Walsall Technical Sales Enclosure Gland Size mm Sides A & B Sides C & D 20 17 14 GLCP11 25 32 10 5 8 4 20 32 14 GLCP12 25 32 18 9 8 4 20 32 29 GLCP13 25 32 18 9 16 8 20 42 38 GLCP14 25 32 27 14 25 14 PANEL LAYOUTS Enclosure GLCP11 No. of horizontal rails. 2 No. of functions per rail 3 GLCP12 2 or 4 5 or 3 GLCP13 4 5 GLCP14 4 5 Note that meters take up two horizontally adjacent positions. If terminals are required in the layout, allowances must be made by calculating the width of the terminal block and deducting this length from the available rail capacity. All Dimensions in mm ORDERING INFORMATION The information given above is for guidance only. In practice customised control panels are specified jointly between the customer and Walsall Technical Sales. Following an initial discussion, drawings are produced by Walsall for approval by the customer. Orders can be placed and accepted using the drawings for reference. 125 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 126 Customised Control Panels - Stainless Steel Enclosure Type XLCP - EEx edm Customised Control Panel PART 2.7 XLCP RANGE EEx edm IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST The EEx edm approved control functions listed on pages 83-88 can be installed in EEx e approved enclosures fabricated from sheet stainless steel to engineer a wide range of customised EEx edm approved control panels. EEx edm IIC customised control panels in stainless steel enclosures. Type XLCP3 – 306mm x 306mm x 150mm Page 128 Type XLCP5 – 458mm x 382mm x 150mm Page 128 Type XLCP6 – 480mm x 480mm x 150mm Page 128 Type XLCP9 – 762mm x 508mm x 150mm Page 128 HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Certification No. Ingress protection ENCLOSURE SPECIFICATION Dimensions CUSTOMISING As a vertically integrated manufacturer Walsall can customise the XLCP range at each stage of the manufacturing process to meet individual customer requirements. II 2 GD EEx e ed em II T6 -40˚C to +40˚C or +50˚C SIRA99ATEX3199 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Material box Material gland plate Finish Cover fixing Gasket Earthing Security Entries Mounting XLCP3 306mm x 306mm x 150mm XLCP5 458mm x 382mm x 150mm XLCP6 480mm x 480mm x 150mm XLCP9 762mm x 508mm x 150mm 1.5mm 316L, (1.4404) stainless 2.5mm 316L, (1.4404) stainless Stainless steel – electropolished Fully detachable hinged cover with captive M6 stainless steel hexagon head slotted screws One piece fire resistant closed cell neoprene for Ta -40˚C One piece silicon rubber for Ta -50˚C 10mm brass internal/external earth stud as standard Optional earth stud welded to cover Optional earth stud welded to gland plate Padlockable hasp Via gland plates 1-4 or direct through body External lugs with 10mm clearance holes Drawing shows typical enclosure e.g XLCP6 ENTRY SPECIFICATION Entries are to customer requirements. The table below give a guide to the gland capacityfor the more commonly used gland sizes. For other gland sizes or mixed sizes consult Walsall Technical Sales. Enclosure Gland Size mm Sides A & B Sides C & D 20 21 15 XL3 25 12 9 Number of Gland plates Location 32 6 4 0 - XL5 25 17 17 20 27 27 1 B 32 9 9 2 AB 20 36 29 3 BCD XL6 25 22 18 32 11 9 20 38 38 XL9 25 24 24 32 12 12 4 ABCD PANEL LAYOUTS. (See diagrams opposite). XL5 XL6 XL9 Enclosure XL3 No. of horizontal rails. 2 4 4 7 No. of functions per rail 3 4 5 6 Note that meters take up two horizontally adjacent positions. If terminals are required in the layout, allowances must be made by calculating the width of the terminal block and deducting this length from the available rail capacity. All Dimensions in mm ORDERING INFORMATION The information given above is for guidance only. In practice customised control panels are specified jointly between the customer and Walsall Technical Sales. Following an initial discussion, drawings are produced by Walsall for approval by the customer. Orders can be placed and accepted using the drawings for reference. 127 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 128 PART 3.0 CONTROL IN CAST IRON, CAST STAINLESS STEEL, AND CAST ALUMINUM ENCLOSURES Comprehensive ranges of EE x d IIC standard local control stations and customised control panels in enclosures manufactured from cast iron, cast aluminium and cast stainless steel. 3.1 CD Range Page 131 EEx d control actuators 3.2 E11 Range Page 135 EEx d local control stations in cast iron enclosures 3.3 ASMCP Range Page 145 EEx d Customised control panels in cast iron, cast aluminium and cast stainless steel enclosures 3.4 COMBINED EEx d AND EEx edm CONTROL SYSTEMS Page 149 EEx d Customised control panels in cast iron, cast aluminium and cast stainless steel enclosures combined with EEx edm terminal and control panels 129 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 130 EEx d Control Actuators Introduction PART 3.1 CD RANGE EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST INTRODUCTION A comprehensive range of EEx d switch/pushbutton actuators, indicator lens and viewing windows for installation in EEx d approved enclosures manufactured in cast iron, cast aluminium and cast stainless steel. Introduction Page 132 Type CD – Switch handles and actuators Page 133 Type CD – Push Button actuators Page 133 Type CD – Indicator lens Page 134 Type CD – Viewing windows Page 134 Standard ie not Ex approved, electrical equipment can be installed in enclosures with ‘d’ type protection. These enclosures are normally cast from iron, aluminium or stainless steel. In order to operate the installed electrical equipment actuators are required that are fixed to the outside surface of the ‘d’ enclosures and which pass through the walls of the enclosure to engage the equipment within. These actuators must incorporate a ‘d’ flamepath that passes through the wall of the enclosure and are therefore special purpose devices designed and approved to EEx d IIC type protection. The Walsall range of ‘d’ actuators includes rotational shafts and handles for switch applications, spring operated vertical shafts and operators for pushbutton applications, metal clad toughed glass indicator lenses and metal clad toughened glass viewing windows for observing instrumentation and measuring devices. The process for defining the elements of a complete ‘d’ system is shown below. Standard Electrical Equipment 131 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com + ‘d’ actuators + ‘d’ enclosure = tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com ‘d’ control systems 132 EEx d Control Actuators Type CD - Switch and Pushbutton Actuators EEx d IIB Zones 1,2,21,22 T6 EEx d Control Actuators Type CD - Indicator Lens and Viewing Windows Group II Cat 2 ATEX/GOST The following EEx d approved pushbutton and switch actuators, are available for mounting on the external surface of EEx d enclosures in order to operate the electrical equipment assembled internally. EEx d IIB Zones 1,2,21,22 INDICATOR LENS HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION II 2 GD EEx d IIC T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1307 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection PRODUCT SPECIFICATION Flamepath Handle Shroud Locking Group II Cat 2 ATEX/GOST The following EEx d approved indicator lamp lens and viewing windows are available for mounting on the external surface of EEx d enclosures in order to observe the electrical equipment assembled internally. SWITCH ACTUATORS Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection T6 II 2 GD EEx d IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1313 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 PRODUCT SPECIFICATION Brass housing with clear toughened glass lens held in position with cement and Brass shaft in brass housing of minimum length of 20mm Polycarbonate Polycarbonate Positions as required threaded ring. ORDERING INFORMATION ORDERING INFORMATION Description Black switch handle with black surround for on/off, changeover, and position switching. Red handle with yellow surround for switch disconnecting, locking in off position Heavy Duty handle for switching 100amps or more Product Code CD1 CD2 CD3 Note: Labeling to order. Description Viewing lens Note: Labeling to order. VIEWING WINDOWS HAZARDOUS AREA SPECIFICATION PUSHBUTTON ACTUATORS Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIC T6 -40˚C to + 50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA02ATEX1307 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 PRODUCT SPECIFICATION Brass shaft in brass housing of minimum length of 20mm Polycarbonate Polycarbonate Cast Housing in Iron, Aluminium or Stainless Steel with 10mm borosilicate glass ORDERING INFORMATION Description 70mm x 70mm 200mm x 100mm ORDERING INFORMATION Description Green pushbutton with spring action. Red pushbutton with spring action. Red pushbutton with lever release. Red mushroom pushbutton with lever release. Emergency mushroom pushbutton with lever release. 133 II 2 GD EEx d II T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1307 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1991 PRODUCT SPECIFICATION Material Flamepath Handle Shroud Product Code CD9 Product Code CD10 CD11 Product Code CD4 CD5 CD6 CD7 CD8 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 134 Local Control Station - Cast Iron Enclosure Type E110 - EEx d IIC General Purpose 20amp switch PART 3.2 E11 RANGE EEx d IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION EEx d IIC Local Control Stations in Cast Iron Enclosures. A comprehensive range of one and two function EEx d local control stations in very robust cast iron enclosures. Type E110 – General Purpose 20 Amp Switch Page 136 Type E116 – Pushbutton Page 137 Type E116 – Emergency Stop Pushbutton Page 138 Type E116 – Double Pushbuttons Page 139 Type E113 – Ammeter Page 140 Type E114 – Indicator Lamp Page 141 Type E118 – Photocell Page 142 Type E110 – Fuse Unit Page 143 Multiple Assemblies Page 144 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1307 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Colour Weight Cover fixing Gasket Plastic components Operator flamepath Security Earthing Mounting 117mmx117mmx143mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 5.1 Kg M6 allen head stainless steel screws Nitrile O ring Polycarbonate Brass shaft in a brass housing Switches with an off position have a padlock ‘off’ ‘facility as standard Internal and external EEx e brass clamps on base Through 10mm holes cast into base ENTRY SPECIFICATION 1x20mm EEx d threaded hole at A and B as standard. All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION Switch: 2 and 4 pole rotary cam switch to IEC60 947. Voltage Volts 380-440 Current AC21A (A) 20 Power AC23A(Kw) 7.5 AC-3A(Kw) 7.5 Conductor Size mmsq. Max. 2.5 All Dimensions in mm ORDERING INFORMATION Current Rating 20 amps 20 amps 20 amps For 25 mm entries add/25 to Product Code e.g. E110006/25 135 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Switch Position Off-On 1 - Off - 2 1-2 Poles 4 2 2 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code E110006 E110003 E110002 136 Local Control Station - Cast Iron Enclosure Type E116 - EEx d IIC Push Button EEx d IIC Zones 1,2,21,22 T6 Local Control Station - Cast Iron Enclosure Type E116 - EEx d IIC Emergency Stop Pushbutton Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Mounting II 2 GD EEx d IIC T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1312 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection T6 Group II Cat 2 ATEX/GOST II 2 GD EEx d IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1312 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION 117mmx117mmx147mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 5.1 Kg M6 allen head stainless steel screws Nitrile O ring Polycarbonate Brass shaft in brass housing, nitrile O ring seal Internal and external EEx e brass clamps on base Earth on cover Through 10mm holes cast into base Dimensions Material Finish Colour Weight Cover fixing Gasket Plastic components Operator flamepath Earthing Mounting ENTRY SPECIFICATION 117mm x 117mm x 147mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 5.1 Kg M6 allen head stainless steel screws Nitrile O ring Polycarbonate Brass shaft in brass housing with nitril O ring seal Internal and external EEx e brass clamps on base Earth on cover Through 10mm holes cast into base ENTRY SPECIFICATION 1x20mm EEx d threaded hole at A and B as standard All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option 1x20mm EEx d threaded hole at A and B as standard. All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Contactors to IEC 60 947. BS EN 60 947 Contactor to IEC 60 947 . BS EN 60 947 Voltage Volts 220-240 415 Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Colour Weight Cover fixing Gasket Plastic components Operator flamepath Earthing EEx d IIC Current AC15 (A) 3 2 Conductor Size mmsq. Max 2.5 2.5 Voltage Volts 220-240 415 All Dimensions in mm Current AC15 (A) 3 2 Conductor Size mmsq. Max 2.5 2.5 All Dimensions in mm ORDERING INFORMATION Description Shrouded Green Pushbutton Shrouded Red Pushbutton Exposed Red Pushbutton For 25 mm entries add/25 to Product Code e.g. E116001/25 137 Label start stop stop Contacts 1 n/o and 1n/c 1 n/o and 1n/c 1 n/o and 1n/c Product Code E116001 E116002 E116003 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com ORDERING INFORMATION Description Single mushroom head emergency ‘stop’ with latching For 25 mm entries add/25 to Product Code e.g. E110006/25 Contacts 1 n/o & 1 n/c tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code E116010 138 Local Control Station - Cast Iron Enclosure Type E113 - EEx d IIC Ammeter Local Control Station - Cast Iron Enclosure Type E116 - EEx d IIC Double Pushbuttons EEx d IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST II 2 GD EEx d IIC T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1312 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Mounting T6 Group II Cat 1,2,3 ATEX/GOST II 2 GD EEx d IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1309 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1991 ENCLOSURE SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Colour Weight Cover fixing Gasket Plastic components Operator flamepath Earthing Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection EEx d IIC Dimensions Material Finish Colour Weight Cover fixing Gasket Glass Earthing 117mm x 117mm x 147mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 5.1Kg M6 allen head stainless steel screws Nitrile O ring Polycarbonate Brass shaft in brass housing., nitrile O ring seal Internal and external EEx e brass clamps on base Earth on cover Through 10mm holes cast into base Mounting 117mm x 117mm x 138mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 5.1 Kg M6 allen head stainless steel screws Nitrile O ring Toughened Borosilicate Internal and external EEx e brass clamps on base Earth on cover Through 10mm holes cast into base ENTRY SPECIFICATION ENTRY SPECIFICATION 1x20mm EEx d threaded hole at A and B as standard. All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option 1x20mm EEx d threaded hole at A and B as standard All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Moving iron ammeter with adjustable red secondary pointer and overload scale. Contactors to IEC 60 947. BS EN 60 947 Voltage Volts 220-240 414 Current AC15 (A) 3 2 Voltage Volts To 300 Conductor Size mmsq. Max 2.5 2.5 Current (direct) Amps 30 Current (transformer) Amps 1 Conductor Size mmsq. Max 4.0 All Dimensions in mm METER SCALES All Dimensions in mm ORDERING INFORMATION Description Shrouded Green ’start’ and shrouded red ‘stop’ Shrouded Green ’start’ and exposed red ‘stop’ Shrouded Green ’start’ and shrouded red latching ‘stop’ Shrouded Green ’start’ and exposed red latching ‘stop’ Contacts (each) 1 n/o & 1 n/c 1 n/o & 1 n/c 1 n/o & 1 n/c 1 n/o & 1 n/c Product Code E116005 E116006 E116009 E116007 For 25 mm entries add/25 to Product Code e.g. E116005/25 139 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Direct operated 0 - 2 - 12 amps 0 - 5 - 30 amps 0 - 30 - 180 amps Operated from current transformer with 1 amp secondary 0 - 80 - 480 amps 0 - 40 - 240 amps 0 - 15 - 90 amps 0 - 100 - 600 amps 0 - 50 - 300 amps 0 - 20 - 120 amps 0 - 150 - 900 amps 0 - 60 - 360 amps 0 - 30 - 180 amps 0 - 200 - 1200 amps ORDERING INFORMATION Description Ammeter For 25 mm entries add/25 to Product Code e.g. E113001/25 Meter Scales To be specified tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code E113001 140 Local Control Station - Cast Iron Enclosure Type E118 - EEx d IIC Photocell Local Control Station - Cast Iron Enclosure Type E114 - EEx d IIC Single and Twin Indicator Lamps EEx d IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Apparatus standard Certification No. Ingress protection EEx d IIC II 2 GD EEx d II T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC EN 50014:1998 and EN 50018: 1995 SIRA02ATEX1310 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1314 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material Finish Colour Weight Cover fixing Gasket Glass Earthing Dimensions Material Finish Colour Weight Cover fixing Gasket Glass Earthing 117mm x 117mm x 138mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 5.1Kg M6 allen head stainless steel screws Nitrile O ring Toughened Internal and external EEx e brass clamps on base Earth on cover Through 10mm holes cast into base Mounting Mounting 117mm x 117mm x 138mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 5.1Kg M6 allen head stainless steel screws Nitrile O ring Toughened Internal and external EEx e brass clamps on base Earth on cover Through 10mm holes cast into base ENTRY SPECIFICATION ENTRY SPECIFICATION 1x20mm EEx d threaded hole at A and B as standard. All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option 1x20mm EEx d threaded hole at A and B as standard All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Photocell: Sealed silicon photo diode. Lamps. Transformer operated 6.5 Volts, 0.15 Amps, MES type Voltage Volts 240 Conductor Size mmsq. Max 2.5 2.5 2.5 Voltage Volts 110-120 200-250 380-440 Temperature Range ˚C -20˚C to +60˚C Power Consumption watts 0.25 All Dimensions in mm Conductor mmsq 2.5 All Dimensions in mm ORDERING INFORMATION Description Single Green Single Red Single Amber Single White Product Code E114001 E114002 E114003 E114004 Description Green and Red Green and Amber Green and White Product Code E114005 E114006 E114007 Description Red and Amber Red and White Amber and White Product Code E114008 E114009 E114010 ORDERING INFORMATION Description Photocell For 25 mm entries add/25 to Product Code e.g. E118001/25 Product Code E118001 For 25 mm entries add/25 to Product Code e.g. E114004/25 141 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 142 Local Control Station - Cast Iron Enclosure Type E110 - EEx d IIC Fuse Unit EEx d IIC Zones 1,2,21,22 T6 Multiple Assemblies Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Individual units in the range should be fixed through the external fixing strap provided when mounted individually. When two or more units are directly connected together it is a condition of the certification that they are supplied as a factory built assembly on steel back plates as shown below. Any combination of the listed individual units can be joined together in 2, 3 or 4 gang configurations. These assemblies can be mounted either horizontally or vertically. II 2 GD EEx d IIC T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1308 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Colour Weight Cover fixing Gasket Earthing Mounting 117mm x 117mm x 116mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 5.1Kg M6 allen head stainless steel screws Nitrile O ring Internal and external EEx e brass clamps on base Earth on cover Through 10mm holes cast into base ENTRY SPECIFICATION 1x20mm EEx d threaded hole at A and B as standard All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION Fuse: 16 Amp fuse links Voltage Volts 240 Current Amps 16 Conductor Size mmsq. Max 2.5 All Dimensions in mm ORDERING INFORMATION Description Single pole and neutral Double pole For 25 mm entries add/25 to Product Code e.g. E112001/25 143 Product Code E112001 E112002 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 144 Customised Control Panels - Cast Aluminium Enclosure Type ASMCP/AL - EEx d Customised Control Panels PART 3.3 ASMCP RANGE EEx d IIB EEx d IIB Customised Control Panels in cast Iron, cast aluminum and cast stainless steel enclosures. Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST The EEx d approved actuators listed can be used to operate standard (not EEx approved) electrical and electronic equipment installed in EEx d approved enclosures of cast aluminium to engineer customised EEx d approved control systems. Two sizes of enclosures are available. The type of equipment that can be installed in the enclosures is limited by the volume of the equipment and the maximum power dissipation permitted. HAZARDOUS AREA SPECIFICATION Type ASMCP/AL - Customised control panels in cast aluminium enclosures Page 146 Type ASMCP/CI - Customised control panels in cast iron enclosures Page 147 Ingress protection Power dissipation Type ASMCP/SS - Customised control panels in cast stainless steel enclosures Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. II 2 GD EEx d IIB T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X. SIRA03ATEX1215 POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 7.0 Watts at +40˚C, 62 Watts at +50˚C Page 148 ENCLOSURE SPECIFICATION Dimensions CUSTOMISING As a vertically integrated manufacturer Walsall can customise the ASMCP range at each stage of the manufacturing process to meet individual customer requirements. ASMCP130/AL - 210mm x 185mm x 152mm ASMCP150/AL – 335mm x 310mm x 200mm Cast aluminium LM6 Epoxy powder coated black ASMCP130/AL 6.0Kg ASMCP150/AL 17Kg M8 allen head stainless steel screws One piece closed cell 4mm neoprene Base- internal and external EEx e brass clamps Cover – internal EEx e brass clamp 2 steel mounting straps. 8mm diameter fixing holes Material Finish Weight empty Cover fixing Gasket Earthing Mounting ENTRY SPECIFICATION Entries are to customer requirements. The table below give a guide to the gland capacity for the more commonly used gland sizes. For other gland sizes or mixed sizes consult Walsall Technical Sales. All entries are fitted with an EEx d approved stopping plug or cable gland. Enclosure Gland Size mm Sides A & B Sides C & D 20 5 5 ASMCP130/AL 25 5 5 32 2 3 20 11 11 ASMCP150/AL 25 32 8 7 8 7 All Dimensions in mm 40 3 3 PANEL LAYOUTS. Enclosure No. of horizontal rails. No.of Actuators Permitted in Cover ASMCP130/AL ASMCP150/AL 1 2 2 12 ORDERING INFORMATION The information given above is for guidance only. In practice customised control panels are specified jointly between the customer and Walsall Technical Sales. Following an initial discussion, drawings are produced by Walsall for approval by the customer. Orders can be placed and accepted using the drawings for reference. 145 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 146 Customised Control Panels - Cast Iron Enclosure Type ASMCP/CI - EEx d Customised Control Panels EEx d IIB Zones 1,2,21,22 T6 Customised Control Panels - Cast Stainless Steel Enclosure Type ASMCP/SS - EEx d Customised Control Panels Group II Cat 2 ATEX/GOST The EEx d approved actuators listed can be used to operate standard (not EEx approved) electrical and electronic equipment installed in EEx d approved enclosures of cast iron to engineer customised EEx d approved control systems. Three sizes of enclosures are available. The type of equipment that can be installed in the enclosures is limited by the volume of the equipment and the maximum power dissipation permitted. Ingress protection Power dissipation Material Finish Weight empty Cover fixing Gasket Earthing Mounting II 2 GD EEx d IIB T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X. SIRA03ATEX1215. SIRA04ATEX1267X POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 7.0 Watts at +40˚C, 62 watts at +50˚C, 200 Watts at +50˚C Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Power dissipation ASMCP130/CI - 210mm x 185mm x 152mm ASMCP150/CI – 335mm x 310mm x 200mm ASMCP170/CI - 560mm x 560mm x 245mm Cast Iron 2 pack Epoxy coated to customer spec ASMCP130/CI 20Kg ASMCP150/CI 51Kg ASMCP170/CI 175Kg M8 allen head stainless steel screws One piece closed cell 4mm neoprene Base- internal and external EEx e brass clamps Cover – internal EEx e brass clamp 2 steel mounting straps. 8mm diameter fixing holes Dimensions Material Finish Weight empty Cover fixing Gasket Earthing Mounting 20 11 11 ASMCP150/CL 25 32 40 8 7 3 8 7 3 25 12 12 ASMCP170/CL 32 32 40 12 6 6 12 6 6 All Dimensions in mm 50 3 3 II 2 GD EEx d IIB T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X. SIRA03ATEX1215. SIRA04ATEX1267X POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 7.0 Watts at +40˚C, 62 Watts at +50˚C, 200 Watts at +50˚C ASMCP130/SS - 210mm x 185mm x 152mm ASMCP150/SS– 335mm x 310mm x 200mm ASMCP170/SS - 560mm x 560mm x 245mm Cast Stainless Steel 316 Self colour ASMCP130/SS 21Kg ASMCP150/SS 52Kg ASMCP170/SS 195Kg M8 allen head stainless steel screws One piece closed cell 4mm neoprene Base- internal and external EEx e brass clamps Cover – internal EEx e brass clamp 2 steel mounting straps. 8mm diameter fixing holes Entries are to customer requirements. The table below give a guide to the gland capacity for the more commonly used gland sizes. For other gland sizes or mixed sizes consult Walsall Technical Sales. All entries are fitted with an EEx d approved stopping plug or cable gland. Enclosure Gland Size mm Sides A & B Sides C & D ASMCP130/SS 20 25 32 5 5 2 5 5 3 20 11 11 ASMCP150/SS 25 32 40 8 7 3 8 7 3 25 12 12 ASMCP170/SS 32 32 40 12 6 6 12 6 6 All Dimensions in mm 50 3 3 PANEL LAYOUTS. PANEL LAYOUTS. Enclosure ASMCP130/CI ASMCP150/CI ASMCP170/CI 4 No. of horizontal rails. 1 2 No.of Actuators Permitted in Cover 2 12 16 147 ATEX/GOST ENTRY SPECIFICATION Entries are to customer requirements. The table below give a guide to the gland capacity for the more commonly used gland sizes. For other gland sizes or mixed sizes consult Walsall Technical Sales. All entries are fitted with an EEx d approved stopping plug or cable gland. ASMCP130/CL 20 25 32 5 5 2 5 5 3 Group II Cat 2 ENCLOSURE SPECIFICATION ENTRY SPECIFICATION Enclosure Gland Size mm Sides A & B Sides C & D T6 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Zones 1,2,21,22 The EEx d approved actuators listed can be used to operate standard (not EEx approved) electrical and electronic equipment installed in EEx d approved enclosures of cast stainless steel to engineer customised EEx d approved control systems. Three sizes of enclosures are available. The type of equipment that can be installed in the enclosures is limited by the volume of the equipment and the maximum power dissipation permitted. HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. EEx d IIB Enclosure ASMCP130/SS ASMCP150/SS ASMCP170/SS No. of horizontal rails. 1 2 4 2 12 16 No.of Actuators Permitted in Cover ORDERING INFORMATION ORDERING INFORMATION The information given above is for guidance only. In practice customised control panels are specified jointly between the customer and Walsall Technical Sales. Following an initial discussion, drawings are produced by Walsall for approval by the customer. Orders can be placed and accepted using the drawings for reference. The information given above is for guidance only. In practice customised control panels are specified jointly between the customer and Walsall Technical Sales. Following an initial discussion, drawings are produced by Walsall for approval by the customer. Orders can be placed and accepted using the drawings for reference. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 148 PART 3.4 COMBINED EEx d AND EEx edm CONTROL SYSTEMS Enclosures of different protection concepts may be combined to form more complex systems which efficiently utilise the benefits of each. For example a common combination is that of an electrical device that can only be housed in an EEx d enclosure is connected to an EEx e enclosure which houses the incoming and outgoing cables. This reduces the size of the EEx d enclosure and helps with the installation wiring which is direct into an EEX e enclosure without flamepaths to concern the installer. The interconnection is via an approved line bush/es which provides an EEx d path through the wall of both enclosures, see diagram opposite. APPROVE LINE B Photograph of typical interconnected systems shown opposite. CUSTOMISING As a vertically integrated manufacturer Walsall can customise combined systems at each stage of the manufacturing process to meet individual customer requirements. Frame work for mounting multiple assemblies of EEx e/ EEx d control panels and terminal enclosures are available for customers specification. 149 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 150 PART 4.0 POWER SWITCHING A comprehensive range of changeover switches to 63 amps, 4 and 6 pole switch disconnectors to 315 amps and fused switches to 125 amps as standard all housed in EEx d approved enclosures in cast iron and cast aluminium. Other variations in operating current and number of poles and auxiliaries are available to order. 4.1 RS Range Page 153 EEx d Changeover switches to 63 amps as standard 4.2 SD Range Page 157 EEx d Switch Disconnectors to 315 amps as standard 4.3 SF Range Page 167 EEx d Fused Switch Disconnectors to 125 amps as standard 151 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 152 Power Switching - Cast Iron Enclosure Type RS - EEx d 20, 25, 32 Amps Changeover Switch PART 4.1 RS RANGE EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION EEx d 4 pole change over switches rated from 20 Amps to 63 Amps in cast iron enclosures. Type RS20 – 20 Amps 4 Pole Changeover Switch Page 154 Type RS25 – 25 Amps 4 Pole Changeover Switch Page 154 Type RS32 – 32 Amps 4 Pole Changeover Switch Page 154 Type RS63 – 63 Amps 4 Pole Changeover Switch Page 155 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIB T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA02ATEX1332. GOST ‘R’ POCC GB. гБ05 BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Colour Weight Cover fixing Gasket Security Earthing Mounting 168mm x 145mm x 138mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 6 Kg M6 allen head stainless steel screws By grease Switches with an off position have a padlock ‘off’ ‘facility as standard Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 8.0mm fixing holes ENTRY SPECIFICATION 1x20mm EEx d threaded hole at A, B and C as standard. All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION Switch: 4 pole rotary cam switch to IEC60947-3 Voltage Volts 380-440 380-440 380-440 Current AC21A (A) 20 25 32 Power AC23A(Kw) 5.5 7.5 11 AC-3(Kw) 3.7 5.5 7.5 Conductor Size mmsq. Max. 2.5 6.0 6.0 All Dimensions in mm ORDERING INFORMATION Current Rating 20 amps 20 amps 25 amps 25 amps 32 amps 32 amps For 25 mm entries add/25 to Product Code e.g. RS20C/25 153 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Switch Position 1 - Off - 2 1-2 1 - Off - 2 1-2 1 - Off - 2 1-2 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code RS20C RS20 RS25C RS25 RS32C RS32 154 Power Switching - Cast Iron Enclosure Type RS - EEx d 63 Amps Changeover Switch EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIB T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA02ATEX1332. GOST ‘R’ POCC GB. гБ05. BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Colour Weight Cover fixing Gasket Security Earthing Mounting 220mm x 185mm x 161mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 11Kg M6 allan head stainless steel screws By grease Switches with an off position have a padlock ‘off’ ‘facility as standard Internal and external EEx e brass clamps on base Earth on cover Two steel straps with 8.0mm fixing holes ENTRY SPECIFICATION 1x20mm EEx d threaded hole at A, B and C as standard All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION Switch: 4 pole rotary cam switch to IEC60947-3 Voltage Volts 690 Current AC21A (A) 63 Power AC23A(Kw) 22 AC-3(Kw) 18.5 Conductor Size mmsq. Max. 16 All Dimensions in mm ORDERING INFORMATION Current Rating 63 amps 63 amps For 25 mm entries add/25 to Product Code e.g. E110006/25 155 Switch Position 1 - Off - 2 1- 2 Product Code RS63C RS63 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 156 Power Switching - Cast Iron Enclosure Type SD - EEx d 20-32 Amps 4 Pole Switch Disconnector PART 4.2 SD RANGE EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION EEx d switch disconnectors (to IEC60947-3) in a choice of cast aluminum or cast iron enclosures, with current ratings from 20 Amps to 315 Amps. The standard versions have 4 or 6 poles and 2 auxiliaries. Other configurations can be engineered. Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIB T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA02ATEX1332 GOST’R’ POCC GB. гБ05. B01132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Type SD204 – 20Amps 4 Pole Switch Disconnector Page 158 Type SD254 – 25Amps 4 Pole Switch Disconnector Page 158 Type SD324 – 32Amps 4 Pole Switch Disconnector Page 158 Type SD256 – 25Amps 6 Pole Switch Disconnector Page 159 Type SD326 – 32Amps 6 Pole Switch Disconnector Page 159 Type SD634 – 63Amps 4 Pole Switch Disconnector Page 160 Type SD636 – 63Amps 6 Pole Switch Disconnector Page 161 Type SD804 – 80Amps 4 Pole Switch Disconnector Page 162 Type SD806 – 80Amps 6 Pole Switch Disconnector Page 163 Dimensions Material Finish Colour Weight Cover fixing Gasket Security Earthing Mounting Type SD1004 – 100Amps 4 Pole Switch Disconnector Page 162 Type SD1006 – 100Amps 6 Pole Switch Disconnector Page 163 Type SD1254 – 125Amps 4 Pole Switch Disconnector Page 164 Type SD1256 – 125Amps 6 Pole Switch Disconnector Page 165 Type SD1604 – 160Amps 4 Pole Switch Disconnector Page 164 168mm x 145mm x 138mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 11 Kg M6 allen head stainless steel screws By grease Switches have a padlock ‘off’ ‘facility as standard Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 8.0mm fixing holes ENTRY SPECIFICATION 1x20mm EEx d threaded hole at A and B as standard. All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION Switch: 4 pole switch disconnector to IEC 60947-3 with 2 n/o early break auxiliaries as standard. Voltage Volts 380-440 380-440 380-440 Current AC21A (A) 20 25 32 Power AC23A(Kw) 5.5 7.5 11.0 AC-3(Kw) 3.7 5.5 7.5 Conductor Size mmsq. Max. 2.5 6.0 6.0 All Dimensions in mm Type SD1606 – 160Amps 6 Pole Switch Disconnector Page 165 Type SD2004 – 200Amps 4 Pole Switch disconnector Page 164 Type SD2006 – 200Amps 6 Pole Switch disconnector Page 165 Type SD2504 – 250Amps 4 Pole Switch Disconnector Page 166 Type SD2506 – 250Amps 6 Pole Switch Disconnector Page 166 Type SD3154 – 315Amps 4 Pole Switch Disconnector Page 166 Type SD3156 – 315Amps 6 Pole Switch Disconnector Page 166 157 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com ORDERING INFORMATION Current Rating 20 amps 25 amps 32 amps For 25 mm entries add/25 to Product Code. Switch Position 0-1 0-1 0-1 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code SD204 SD254 SD324 158 Power Switching - Cast Aluminium or Cast Iron Enclosure Type SD - EEx d 25-32 Amps 6 Pole Switch Disconnector EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 Power Switching - Cast Iron Enclosure Type SD - EEx d 63 Amps 4 Pole Switch Disconnector ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Finish Colour Weight Cover fixing Gasket Security Earthing Mounting Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION II 2 GD EEx d IIB T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA03ATEX1215 GOST’R’ POCC GB. гБ05. B01132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection ENCLOSURE SPECIFICATION Dimensions Material EEx d IIB II 2 GD EEx d IIB T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA02ATEX1332 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION 210mm x 185mm x 153mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Zinc rich epoxy powder primer and epoxy powder top coat Black Cast iron 20Kg, Cast aluminium 8Kg M6 allen head stainless steel screws By grease Switches have a padlock ‘off’ ‘facility as standard Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 8.0mm fixing holes Dimensions Material Finish Colour Weight Cover fixing Gasket Security Earthing Mounting 220mmx185mmx161mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 11 Kg M6 allen head stainless steel screws By grease Switches have a padlock ‘off’ ‘facility as standard Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 8.0mm fixing holes ENTRY SPECIFICATION ENTRY SPECIFICATION 1x20mm EEx d threaded hole at A, B and C as standard. All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option 1x20mm EEx d threaded hole at A, B and C as standard All entries are fitted with EEx d stopping plugs as standard ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Switch: Switch disconnector to IEC 60947-3 with 2 n/o early break auxiliaries. Switch: 6 pole switch disconnector to IEC 60947-3 with 2 n/o early break auxiliaries as standard Voltage Volts 380-440 380-440 380-440 Current AC21A (A) 20 25 32 Power AC23A(Kw) 5.5 7.5 11.0 AC-3(Kw) 3.7 5.5 7.5 Voltage Volts 380-440 Conductor Size mmsq. Max. 2.5 6.0 6.0 Current AC21A (A) 63 Power AC23A(Kw) 22 AC-3(Kw) 18.5 Conductor Size mmsq. Max. 16 All Dimensions in mm All Dimensions in mm ORDERING INFORMATION Current Rating 25 amps 32 amps 25 amps 32 amps For 25 mm entries add/25 to Product Code. 159 Enclosure Material Cast Iron Cast Iron Cast Aluminium Cast Aluminium Switch Position 0-1 0-1 0-1 0-1 Product Code SDI256 SDI326 SDA256 SDA326 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com ORDERING INFORMATION Notes: Current Rating Switch Position 63 amps 0-1 For 25 mm entries add/25 to Product Code. Other entry configurations and sizes are available please ask Walsall sales for information. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code SD634 160 Power Switching - Cast Aluminum or Cast Iron Enclosure Type SD - EEx d 63 Amps 6 Pole Switch Disconnector EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 Power Switching - Cast Aluminium or Cast Iron Enclosure Type SD - EEx d 80-100 Amps 4 Pole Switch Disconnector ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIB T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X. GOST ‘R’ POCC GB. IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection гБ05. BO1132 Colour Weight Cover fixing Gasket Security Earthing Mounting Dimensions Material Colour Weight Cover fixing Gasket Security Earthing Mounting ATEX/GOST II 2 GD EEx d IIB T6 -20˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA03ATEX1215 GOST ‘R’ POCC GB. гБ05. BO1132 IP66 to EN60529:1992 ENTRY SPECIFICATION 1x20mm EEx d threaded hole at A, B and C as standard All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option 1x25mm EEx d threaded hole at A, B and C as standard. All entries are fitted with EEx d stopping plugs as standard 32mm entries are available as an option ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Switch: 6 pole switch disconnector to IEC 60947-3 with 2 n/o early break auxiliaries as standard Current AC21A (A) 63 Group II Cat 2 210mm x 185mm x 153mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron - zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium - epoxy powder coat Black Cast iron 20 Kg. Cast aluminium 8 Kg M6 allen head stainless steel screws By grease Switches have a padlock ‘off’ ‘facility as standard Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 8.0mm fixing holes Finish ENTRY SPECIFICATION Voltage Volts 380-440 T6 ENCLOSURE SPECIFICATION 210mm x 185mm x 153mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron- zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium – epoxy powder coat Black Cast iron 20Kg Cast aluminium 8Kg M6 allen head stainless steel screws By grease Switches have a padlock ‘off’ ‘facility as standard Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 8.0mm fixing holes Finish Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material EEx d IIB Power AC23A(Kw) 22 AC-3(Kw) 18.5 Switch: 4 pole switch disconnector to IEC60947 with 2 n/o early break auxiliaries as standard. Conductor Size mmsq. Max. 16 Voltage Volts 380-440 380-440 All Dimensions in mm Current AC21A (A) 80 100 Power AC23A(Kw) 30 37 AC-3(Kw) 22 30 Conductor Size mmsq. Max. 35 35 All Dimensions in mm ORDERING INFORMATION Current Rating 80 amps 100 amps 80 amps 100 amps ORDERING INFORMATION Current Rating 63 amps 63 amps Enclosure Material Cast Iron Cast Aluminium Switch Position 0-1 0-1 Product Code SDI636 SDA636 For 25 mm entries add/25 to Product Code. 161 Notes: tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Enclosure Material Cast Iron Cast Iron Cast Aluminium Cast Aluminium Switch Position 0-1 0-1 0-1 0-1 Product Code SDI804 SDI1004 SDA804 SDA1004 For 32 mm entries add/32 to Product Code. Other entry configurations and sizes are available please ask Walsall sales for information. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 162 Power Switching - Cast Aluminium or Cast Iron Enclosure Type SD - EEx d 80-100 Amps 6 Pole Switch Disconnector EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 Power Switching - Cast Aluminium or Cast Iron Enclosure Type SD - EEx d 125-200 Amps 4 Pole Switch Disconnector ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIB T6 -20˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X. GOST ‘R’ POCC GB. гБ05. BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Colour Weight Cover fixing Gasket Security Earthing Mounting Dimensions Material Colour Weight Cover fixing Gasket Security Earthing Mounting ATEX/GOST II 2 GD EEx d IIB T6 -20˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X. GOST ‘R’ POCC GB. гБ05. BO1132 IP66 to EN60529:1992 ENTRY SPECIFICATION 1x25mm EEx d threaded hole at A, B and C as standard All entries are fitted with EEx d stopping plugs as standard 32mm entries are available as an option 1x25mm EEx d threaded hole at A, B and C as standard. All entries are fitted with EEx d stopping plugs as standard 32mm entries are available as an option ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Switch: 6 poles witch disconnector to IEC60947 with 2 n/o early break auxiliaries as standard Current AC21A (A) 80 100 Group II Cat 2 335mm x 310mm x 200mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron - zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium – epoxy powder coat Black Cast iron 50Kg. Cast aluminium 18Kg M6 allen head stainless steel screws By grease Padlock ‘off’ ‘facility as standard Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 10mm fixing holes Finish ENTRY SPECIFICATION Voltage Volts 380-440 380-440 T6 ENCLOSURE SPECIFICATION 335mm x 310mm x 200mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron - zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium – epoxy powder coat Black Cast iron 50Kg. Cast aluminium 18Kg M6 allen head stainless steel screws By grease Switches have a padlock ‘off’ ‘facility as standard Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 10mm fixing holes Finish Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material EEx d IIB Power AC23A(Kw) 30 37 AC-3(Kw) 22 30 Switch: 4 and 6 pole switch disconnector to IEC 60947 -3 with 2 n/o early break auxiliaries as standard. Conductor Size mmsq. Max. 35 35 Voltage Volts 380-440 380-440 380-440 All Dimensions in mm Current AC21A (A) 125 160 200 Power AC23A(Kw) 45 55 75 AC-3(Kw) 37 45 55 Conductor Size mmsq. Max. 95 95 185 All Dimensions in mm ORDERING INFORMATION Current Rating 125 amps 160amps 200 amps 125 amps 160 amps 200 amps ORDERING INFORMATION Current Rating 80 amps 100 amps 80 amps 100 amps Notes: 163 Enclosure Material Cast Iron Cast Iron Cast Aluminium Cast Aluminium Switch Position 0-1 0-1 0-1 0-1 Product Code SDI806 SDI1006 SDA806 SDA1006 For 32 mm entries add/32 to Product Code. Other entry configurations and sizes are available please ask Walsall sales for information. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Notes: Enclosure Material Cast Iron Cast Iron Cast Iron Cast Aluminium Cast Aluminium Cast Aluminium Switch Position O-1 O-1 O-1 O-1 O-1 O-1 Product Code SDI1254 SDI1604 SDI2004 SDA1254 SDA1604 SDA2004 For 32 mm entries add/32 to Product Code. Other entry configurations and sizes are available please ask Walsall sales for information. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 164 Power Switching - Cast Aluminium or Cast Iron Enclosure Type SD - EEx d 125-200 Amps 6 Pole Switch Disconnector EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 Power Switching - Cast Aluminium or Cast Iron Enclosure Type SD - EEx d 250-315amps 4 & 6 Pole Switch Disconnector ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIB T6 -20˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X. GOST ‘R’ POCC GB. гБ05. BO1132 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Colour Weight Cover fixing Gasket Security Earthing Mounting Dimensions Material Finish Colour Weight Cover fixing Gasket Security Earthing Mounting ENTRY SPECIFICATION ATEX/GOST II 2 GD EEx d IIB T6 -20˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X. GOST ‘R’ POCC GB. гБ05. BO1132 IP66 to EN60529:1992 335mm x 310mm x 200mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron - zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium – epoxy powder coat Black Cast iron 50 Kg. Cast aluminium 18 Kg M6 allen head stainless steel screws By grease Padlock ‘off’ ‘facility as standard Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 10mm fixing holes 1x25mm EEx d threaded hole at A, B and C as standard. All entries are fitted with EEx d stopping plugs as standard 32mm entries are available as an option ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Switch: 4 and 6 pole switch disconnector to IEC 60947 -3 with 2 n/o early break auxiliaries as standard Current AC21A (A) 125 160 200 Group II Cat 2 ENTRY SPECIFICATION 1x25mm EEx d threaded hole at A, B and C as standard All entries are fitted with EEx d stopping plugs as standard 32mm entries are available as an option Voltage Volts 380-440 380-440 380-440 T6 ENCLOSURE SPECIFICATION 335mm x 310mm x 200mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron - zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium – epoxy powder coat Black Cast iron 50Kg. Cast aluminium 18Kg M6 allen head stainless steel screws By grease Padlock ‘off’ ‘facility as standard Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 10mm fixing holes Finish Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material EEx d IIB Power AC23A(Kw) 45 55 75 AC-3(Kw) 37 45 55 Switch: 4 and 6 pole switch disconnector to IEC 60947 -3 with 2 n/o early break auxiliaries as standard. Conductor Size mmsq. Max. 95 95 185 Voltage Volts 380-440 380-440 All Dimensions in mm Current AC21A (A) 200 315 Power AC23A(Kw) 90 110 AC-3(Kw) 55 75 Conductor Size mmsq. Max. 185 185 All Dimensions in mm ORDERING INFORMATION Current Rating 250 amps 250 amps 315 amps 315 amps 250 amps 250 amps 315 amps 315 amps ORDERING INFORMATION Current Rating 125 amps 160amps 200 amps 125 amps 160 amps 200 amps Notes: 165 Enclosure Material Cast Iron Cast Iron Cast Iron Cast Aluminium Cast Aluminium Cast Aluminium Switch Position O-1 O-1 O-1 O-1 O-1 O-1 Product Code SDI1256 SDI1606 SDI2006 SDA1256 SDA1606 SDA2006 For 32 mm entries add/32 to Product Code. Other entry configurations and sizes are available please ask Walsall sales for information. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Notes: Enclosure Material Cast Iron Cast Iron Cast Iron Cast Iron Cast Aluminum Cast Aluminum Cast Aluminum Cast Aluminum Switch Position O-1 O-1 O-1 O-1 O-1 O-1 O-1 O-1 Poles 4 6 4 6 4 6 4 6 Product Code SDI2504 SDI2506 SDI3154 SDI3156 SDA2504 SDA2506 SDA3154 SDA3156 For 32 mm entries add/32 to Product Code. Other entry configurations and sizes are available please ask Walsall sales for information. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 166 Power Switching - Cast Aluminium or Cast Iron Enclosure Type SF - EEx d 20-63 Amp 4 & 6 Pole Fused Switch Disconnector PART 4.3 SF RANGE EEx d IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION EEx d fused switch disconnectors (to IEC60947-3) in a choice of cast aluminum or cast iron enclosures, with current ratings from 20 Amps to 125 Amps. The standard versions have 4 or 6 poles and 2 auxiliaries. Other configuations can be engineered. Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIB T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA02ATEX1332 GOST’R’ POCC GB. гБ05. B01132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Type SF254 – 20 Amps 4 Pole Fused Switch Disconnector Page 168 Dimensions Material Type SF256 – 25 Amps 6 Pole Fused Switch Disconnector Page 168 Finish Type SF324 – 32 Amps 4 Pole Fused Switch Disconnector Page 168 Type SF326 – 32 Amps 6 Pole Fused Switch Disconnector Page 168 Type SF634 – 63 Amps 4 Pole Fused Switch Disconnector Page 168 Type SF636 – 63 Amps 6 Pole Fused Switch Disconnector Page 168 Type SF804 – 80 Amps 4 Pole Fused Switch Disconnector Page 169 Type SF806 – 80 Amps 6 Pole Fused Switch Disconnector Page 169 Type SF1004 – 100 Amps 4 Pole Fused Switch Disconnector Page 169 Type SF1006 – 100 Amps 6 Pole Fused Switch Disconnector Page 169 Type SF1254 – 125 Amps 4 Pole Fused Switch Disconnector Page 169 Type SF1256 – 125 Amps 6 Pole Fused Switch Disconnector Page 169 Colour Weight Cover fixing Gasket Plastic components Operator flamepath Security Earthing Mounting 210mm x 185mm x 153mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron - zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium – epoxy powder coat Black Cast iron 20Kg. Cast aluminium 8Kg M6 allen head stainless steel screws By grease Polycarbonate Brass shaft in brass housing Switches have a padlock ‘off’ ‘facility as standard Cover interlock (cover may not be opened unless switch is in the off position) Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 8.0mm fixing holes ENTRY SPECIFICATION 1x20mm EEx d threaded hole at A, B and C as standard. All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION Fuses: European standard fuses to IEC 269.1&2 Switch: Switch disconnector to IEC 60947-3 with 2 n/o early break auxiliaries. Voltage Volts 380-440 380-440 380-440 Current AC21A (A) 25 32 63 Power AC23A(Kw) 7.5 11.0 22 AC-3(Kw) 5.5 7.5 18.5 Conductor Size mmsq. Max. 6 6 16 All Dimensions in mm ORDERING INFORMATION Notes: 167 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Current Rating Switch Position 20 amps 0-1 25 amps 0-1 0-1 32 amps 0-1 63 amps 0-1 20 amps 0-1 25 amps 0-1 32 amps 63 amps 0-1 For 25 mm entries add/25 to Product Code e.g. SF254/25 Poles 4 4 4 4 6 6 6 6 Product Code Aluminum SFA204 SFA254 SFA324 SFA634 SFA206 SFA256 SFA326 SFA636 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code Iron SFI204 SFI254 SFI324 SFI634 SFI204 SFI256 SFI326 SFI636 168 Power Switching - Cast Aluminium or Cast Iron Enclosure Type SF - EEx d 80-125 Amps 4 & 6 Pole Fused Switch Disconnector EEx d IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIB T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X GOST’R’ POCC GB. гБ05. B01132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Colour Weight Cover fixing Gasket Security Earthing Mounting 335mm x 310mm x 200mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron - zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium – epoxy powder coat Black Cast iron 50Kg Cast aluminium 18Kg M6 allen head stainless steel screws By grease Switches have a padlock ‘off’ ‘facility as standard Cover interlock (cover may not be opened unless switch is in the off position) Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 10mm fixing holes ENTRY SPECIFICATION Switch disconnectors on route to 1x25mm EEx d threaded hole at A, B and C as standard All entries are fitted with EEx d stopping plugs as standard 32mm entries are available as an option Kazakhstan ELECTRICAL SPECIFICATION Fuses: European standard fuses to IEC 269.1&2 Switch: Switch disconnector to IEC 60947-3 with 2 n/o early break auxiliaries Voltage Volts 380-440 380-440 380-440 Current AC21A (A) 80 100 125 Power AC23A(Kw) 30 37 45 AC-3(Kw) 22 30 37 Conductor Size mmsq. Max. 35 35 50 All Dimensions in mm ORDERING INFORMATION Notes: 169 Current Rating Switch Position 0-1 80 amps 0-1 100 amps 0-1 125 amps 0-1 80 amps 0-1 100 amps 0-1 125 amps For 32 mm entries add/32 to Product Code. eg SF1004/32 Poles 4 4 4 6 6 6 Product Code Aluminum SFA804 SFA1004 SFA1254 SFA806 SFA1006 SFA1256 Product Code Iron SFI804 SFI1004 SFI1254 SFI806 SFI1006 SFI1256 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 170 PART 5.0 MOTOR CONTROL A comprehensive range of EEx d DOL and STAR - DELTA motor starters and starter/isolators in a choice of cast iron and cast aluminum enclosures with ratings up to 30 kW. 5.1 DOL Range Page 173 EEx d IIB Direct-on-line Starters and Starter/ Isolators to 30kW 5.2 SDS Range Page 179 EEx d IIB Star-Delta and Starters and Starter/ Isolators to 30kW 171 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 172 Motor Control - Cast Iron Enclosure Type DOL - EEx d 5.5 - 7.5 Amps DOL Starter PART 5.1 DOL RANGE EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION EEx d IIB Direct-on-line Starters and Starter/Isoloators in a choice of cast iron and cast aluminium enclosures from 5.5kW to 30kW. All have a choice of coil voltages and overload currents. Type DOL5.5 – 5.5 kW Direct on Line Starter Page 174 Type DOL7.5 – 7.5 kW Direct on Line Starter Page 174 Type DOL11 – 11kW Direct on Line Starter Page 175 Type DOL15 – 15 kW Direct on Line Starter Page 175 Type DOL22 – 22 kW Direct on Line Starter Page 176 Type DOL30 – 30 kW Direct on Line Starter Page 176 Type DOLSD5.5 – 5.5 kW Starter Isolator Page 177 Type DOLSD7.5 – 7.5 kW Starter Isolator Page 177 Type DOLSD11 – 11 kW Starter Isolator Page 177 Type DOLSD15 – 15 kW Starter Isolator Page 177 Type DOLSD22 – 22 kW Starter Isolator Page 177 Type DOLSD30 – 30 kW Starter Isolator Page 177 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIB T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA02ATEX1332 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Colour Weight Cover fixing Gasket Earthing Mounting 220mm x 185mm x 161mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Black 11 Kg M6 allen head stainless steel screws By grease Internal and external EEx e brass clamps on base Earth on cover Two steel straps with 8.0mm fixing holes ENTRY SPECIFICATION 1x20mm EEx d threaded hole at A, B and C as standard. All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION Contactor: 1 and 3 phase, 50/60 Hz contactors to IEC947-4 with push button operators fitted with thermal overload protection and coil voltages as specified below. kW 5.5 7.5 Contactor Ratings Amps (AC3) Volts 12 415 16 415 Conductor Size mmsq. Max.* 2.5 2.5 Coil Voltages 60Hz 50Hz 110 110 220 120 460 380 415 440 480 Overloads Amps Amps 0.14-0.23 2.00-3.30 0.20-0.33 3.00-5.00 0.30-0.50 4.50-7.50 0.45-0.75 6.00-10.00 0.60-1.00 9.00-15.00 0.90-1.50 14.00-23.00 1.40-2.30 All Dimensions in mm * For flexible cable. For solid cable multiply by 1.6 ORDERING INFORMATION To order use the following sequence of letters and numbers. DOL 5.5 3 415 1.4/2.3 TYPE RATING PHASES COIL VOLTAGE OVERLOAD CURRENT Note: For 25 mm entries add/25 to Product Code 173 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 174 Motor Control - Cast Aluminium or Cast Iron Enclosure Type DOL - EEx d 11-15kW DOL Starter EEx d IIB Zones 1,2,21,22 T6 Motor Control - Cast Aluminium or Cast Iron Enclosure Type DOL - EEx d 22-30 kW DOL Starter Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Finish Colour Weight Cover fixing Gasket Plastic components Operator flamepath Earthing Mounting Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION II 2 GD EEx d IIB T6 -20˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA03ATEX1215X. GOST ‘R’ POCC GB. гБ05. BO1132 IP66 to EN60529:1991 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection ENCLOSURE SPECIFICATION Dimensions Material EEx d IIB II 2 GD EEx d IIB T6 -20˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X GOST ‘R’ POCC GB. гБ05. BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION 210mm x 185mm x 153mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron- Zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium- epoxy powder coat Black Cast iron 20Kg, cast aluminium 8Kg M6 allen head stainless steel screws. By grease Polycarbonate Brass shaft in brass housing Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 8.0mm fixing holes Dimensions Material Finish Colour Weight Cover fixing Gasket Earthing Mounting 335mm x 310mm x 200mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron- Zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium- epoxy powder coat Black Cast iron 50 Kg , cast aluminium 18 Kg M6 allen head stainless steel screws By grease Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 10mm fixing holes ENTRY SPECIFICATION ENTRY SPECIFICATION 1x25mm EEx d threaded hole at A, B and C as standard. All entries are fitted with EEx d stopping plugs as standard 32mm entries are available as an option 1x25mm EEx d threaded hole at A, B and C as standard All entries are fitted with EEx d stopping plugs as standard 32mm entries are available as an option ELECTRICAL SPECIFICATION Contactor: 3 phase, 50/60 Hz contactors to IEC947-4 with push button operators, fitted with thermal overload protection and coil voltages as specified below. ELECTRICAL SPECIFICATION Contactor: 3 phase, 50/60 Hz contactors to IEC947-4 with push button operators, fitted with thermal overload protection and coil voltages as specified below. kW 11 15 Contactor Ratings Amps (AC3) 21 30 Volts 415 415 Conductor Size mmsq. Max.* 2.5 6 Coil Voltages 60Hz 50Hz 110 110 220 120 460 380 415 440 480 Overloads Amps 14-23 17-26 20-33 All Dimensions in mm kW 22 30 Volts 415 415 Conductor Size mmsq. Max.* 16 16 Coil Voltages 60Hz 50Hz 110 110 220 120 460 380 415 440 480 500 690 Overloads Amps 28-42 35-50 46-65 * For flexible cable. For solid cable multiply by 1.6 * For flexible cable. For solid cable multiply by 1.6 ORDERING INFORMATION To order use the following sequence of letters and numbers. ORDERING INFORMATION To order use the following sequence of letters and numbers. DOL 15 3 415 20/33 TYPE Note1: 175 Contactor Ratings Amps (AC3) 48 55 RATING PHASES COIL VOLTAGE DOL 22 3 415 35/50 OVERLOAD CURRENT For 25 mm entries add/25 to Product Code For Enclosures in cast aluminum add A to product code and I for Cast Iron Enclosures tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com All Dimensions in mm TYPE Note1: RATING PHASES COIL VOLTAGE OVERLOAD CURRENT For 25 mm entries add/25 to Product Code For Enclosures in cast aluminum add A to product code and I for Cast Iron Enclosures tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 176 Motor Control - Cast Aluminium or Cast Iron Enclosure Type DOLSD - EEx d 5.5-30kW DOL Starter/Isolator EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIB T6 -20˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA042ATEX1266X. GOST ‘R’ POCC. GB. гБ05. BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting 335mm x 310mm x 200mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron- Zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium- epoxy powder coat Cast iron 50Kg , cast aluminium 18Kg M6 allen head stainless steel screws By grease Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 10mm fixing holes ENTRY SPECIFICATION 1x25mm EEx d threaded hole at A, B and C as standard. All entries are fitted with EEx d stopping plugs as standard 32mm entries are available as an option ELECTRICAL SPECIFICATION Contactor: 3 phase, 50/60 Hz contactors to IEC947-4 with push button operators, fitted with thermal overload protection and coil voltages as specified below Isolator: Switch disconnector to IEC 60947-3 with2 n/o early break auxiliaries as standard. kW 5.5 7.5 11 15 22 30 Contactor Ratings Amps (AC3) 12 16 21 30 48 55 Volts 415 415 415 415 415 415 Conductor Size mmsq. Max.* 2.5 2.5 2.5 6 16 16 Coil Voltages 50Hz 60Hz 110 110 220 120 460 380 415 440 480 Overloads Amps Amps 0.14-0.23 6-10 0.20-0.33 9-15 0.30-0.50 14-23 0.45-0.75 17-26 0.60-1.00 20-33 0.90-1.50 28-42 1.40-2.30 35-50 2.0-3.3 46-65 3-5 60-82 4.5-7.5 70-95 All Dimensions in mm * For flexible cable. For solid cable multiply by 1.6 ORDERING INFORMATION To order use the following sequence of letters and numbers. DOL/SD 22 3 415 35/50 TYPE Note1: 177 RATING PHASES COIL VOLTAGE OVERLOAD CURRENT For 25 mm entries add/25 to Product Code For Enclosures in cast aluminum add A to product code and I for Cast Iron Enclosures tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 178 Motor Control - Cast Aluminium or Cast Iron Enclosure Type SDS - EEx d 11-30kW Star Delta Starter PART 5.2 SDS RANGE EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION EEx d IIB Star Delta and Starter/Isolators in a choice of cast iron and cast aluminium enclosures from 5.5kW to 30kW. All have a choice of coil voltages and overloads currents. Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Type SDS11 – 11kw Star-Delta Starter Page 180 Type SDS15 – 15kw Star-Delta Starter Page 180 Type SDS22 – 22kw Star-Delta Starter Page 180 Dimensions Material Type SDS30 – 30kw Star-Delta Starter Page 180 Finish Type SDSI11 – 11kw Star-Delta Starter Isolator Page 181 Type SDSI15 – 15kw Star-Delta Starter Isolator Page 181 Type SDSI22 – 22kw Star-Delta Starter Isolator Page 181 Type SDSI30 – 30kw Star-Delta Starter Isolator Page 181 Colour. Weight Cover fixing Gasket Plastic components Operator flamepath Earthing II 2 GD EEx d IIB T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X. GOST ‘R’ POCC GB. гБ05 BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Mounting 335mm x 310mm x 200mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron- Zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium- epoxy powder coat Black Cast iron 50 Kg , cast aluminium 18 Kg M6 allen head stainless steel screws By grease Polycarbonate Brass shaft in brass housing Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 10mm fixing holes ENTRY SPECIFICATION 1x25mm EEx d threaded hole at A, B and C as standard. All entries are fitted with EEx d stopping plugs as standard 32mm entries are available as an option ELECTRICAL SPECIFICATION Contactor: 3 phase, 50/60 Hz contactors to IEC947-4 with push button operators, fitted with thermal overload protection and coil voltages as specified below. kW 11 15 22 30 Contactor Ratings Amps (AC3) 21 30 48 58 Volts 415 415 415 415 Coil Voltages Conductor Size 60Hz mmsq. Max.* 50Hz 2.5 10/120 110 6 380/415 240 460 16 440 480 16 Overloads Amps 17-26 20-30 28-42 35-50 46-65 60-82 70-95 All Dimensions in mm * For flexible cable. For solid cable multiply by 1.6 ORDERING INFORMATION To order use the following sequence of letters and numbers. SDS 15 415 28/45 TYPE Note1: 179 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com RATING COIL OVERLOAD VOLTAGE CURRENT For 25 mm entries add/25 to Product Code For Enclosures in cast aluminum add A to product code and I for Cast Iron Enclosures tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 180 Motor Control - Cast Aluminium or Cast Iron Enclosure Type SDSI - EEx d 11- 30kW Star Delta Starter/Isolator EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIB T6 -20˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1266X GOST ‘R’ POCC GB гБ05 BO1132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Plastic components Operator flamepath Earthing Mounting 335mm x 310mm x 200mm Cast iron to 180BSI1452:1997 Cast aluminium to LM6 Cast iron- Zinc rich epoxy powder primer and epoxy powder top coat Cast aluminium- epoxy powder coat Cast iron 50Kg , cast aluminium 18Kg M6 allen head stainless steel screws By grease Polycarbonate Brass shaft in brass housing Internal and external EEx e brass clamps on base Earth on cover Two steel mounting straps with 10mm fixing holes ENTRY SPECIFICATION 1x25mm EEx d threaded hole at A, B and C as standard All entries are fitted with EEx d stopping plugs as standard 32mm entries are available as an option EEx d control panels designed and manufactured for a major process ELECTRICAL SPECIFICATION installation in Abu Dhabi Contactor: 3 phase, 50/60 Hz contactors to IEC947-4 with push button operators, fitted with thermal overload protection and coil voltages as specified below Isolator: Switch disconnector to IEC 60947-3 with 2 n/o early break auxiliaries as standard kW 11 15 22 30 Contactor Ratings Amps (AC3) 21 30 48 58 Volts 415 415 415 415 Coil Voltages Conductor Size mmsq. Max.* 50Hz 60Hz 2.5 10/120 110 6 380/415 240 16 460 440 16 480 Overloads Amps 17-26 20-30 28-42 35-50 46-65 60-82 70-95 All Dimensions in mm * For flexible cable. For solid cable multiply by 1.6 ORDERING INFORMATION To order use the following sequence of letters and numbers. SDSI 15 415 28/45 TYPE Note1: 181 RATING COIL OVERLOAD VOLTAGE CURRENT For 25 mm entries add/25 to Product Code For Enclosures in cast aluminum add A to product code and I for Cast Iron Enclosures tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 182 PART 6.0 DISTRIBUTION BOARDS 183 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Type DBD150- 63Amp switched distribution board with 16Amp MCBs Page 185 Type DBD170- 100Amp switched distribution board with 16Amp MCBs Page 186 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 184 Distribution Board - Cast Aluminium and Cast Iron Enclosures Type DBD150 – EEx d 63 amps switched distribution box with 16amp MCBs EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST II 2 GD EEx d IIB T6 -40˚C to + 50˚C Zones 1,2,21,22 . Groups IIA, IIB SIRA04ATEX1226X POCC. GB. гБ 05.BO1132 IP66 to EN60529:1992 Maximum 62 watts at +50C Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Power dissipation ENCLOSURE SPECIFICATION Dimensions Material Weight empty Cover fixing Gasket Earthing Mounting Dimensions Material Finish Weight empty Cover fixing Gasket Earthing Mounting ENTRY SPECIFICATION MCBs 30 x 1 pole 18 x 2 pole 12 x 3 pole ELECTRICAL SPECIFICATION Switch Disconnector MCBs Incoming and outgoing terminals Wiring ATEX/GOST II 2 GD EEx d IIB T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB SIRA04ATEX1227X POCC. GB. гБ 05.BO1132 IP66 to EN60529:1991 Maximum 200 Watts at +50˚C 560mm x 560mm x 245mm Cast aluminium LM6 Cast iron to 180BSI1452:1997 Aluminium - epoxy powder coated RAL 7032 Iron- Zinc rich epoxy powder primer and epoxy powder top coat Aluminium 65Kgs, cast iron 190Kgs Hinged with M10 allen head stainless steel screws One piece closed cell 4mm neoprene Base- internal and external EEx e brass clamps Cover – internal EEx e brass clamp 2 steel U shaped mounting straps. 10mm diameter fixing holes Entries Side A 1 x M32 + 6 x M20 1 x M32 + 6 x M20 1 x M32 Entries Side C 12 x M20 6 x M20 6 x M20 Entries Side D 12 x M20 6 x M20 6 x M20 ELECTRICAL SPECIFICATION 1x 63 amp 4 pole incoming switch disconnector to IEC60947-3 1,2 and 3 pole 16 amp MCBs to IEC898 WDU type as appropriate Not wired as standard Optional wiring service available Switch Disconnector MCBs Incoming and outgoing terminals Wiring All Dimensions in mm ORDERING INFORMATION 185 Group II Cat 2 All entries EEx d threaded and fitted with EEx d stopping plugs or glands as appropriate Entries Side A 1 x M25 + 9 x M20 1 x M25 + 6 x M20 1 x M25 + 4 x M20 MCBs 9 x 1 pole 6 x 2 pole 4 x 3 pole Notes: T6 ENTRY SPECIFICATION All entries EEx d threaded and fitted with EEx d stopping plugs or glands as appropriate Switch Amps 63 63 63 Zones 1,2,21,22 ENCLOSURE SPECIFICATION 335mm x 310mm x 200mm Cast aluminium LM6 Cast iron to 180BSI1452:1997 Aluminium - epoxy powder coated RAL 7032 Iron - Zinc rich epoxy powder primer and epoxy powder top coat, black Cast aluminium 17Kgs, Cast iron 50Kgs M6 allen head stainless steel screws One piece closed cell 4mm neoprene Base- internal and external EEx e brass clamps Cover – internal EEx e brass clamp 2 steel mounting straps. 10mm diameter fixing holes Finish EEx d IIB HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Power dissipation Distribution Board - Cast Iron Enclosures Type DBD170 – EEx d 100 amps switched distribution box with 16amp MCBs 1x 100 Amp 4 pole incoming switch disconnector to IEC60947-3 1,2 and 3 pole 16 amp MCBs to IEC898 WDU type as appropriate Not wired as standard Optional wiring service available All Dimensions in mm ORDERING INFORMATION Entries 1 x M25 + 9 x M20 1 x M25 + 6 x M20 1 x M25 + 4 x M20 16amp MCBs 9 x 1 pole 6 x 2 pole 4 x 3 pole Incoming Terminals 4 x WDU16 + 1 x WPE16 4 x WDU16 + 1 x WPE16 4 x WDU16 + 1 x WPE16 Outgoing Terminals 9 x WDU2.5 + 9 x WPE2.5 12 x WDU2.5 + 6 x WPE2.5 12 x WDU2.5 + 4 x WPE2.5 Product Code DBD150/91 DBD150/62 DBD150/43 Switch Amps 100 100 100 Entries 1 x M32 + 30 x M20 1 x M32 + 18 x M20 1 x M32 + 12 x M20 16amp MCBs 30 x 1 pole 8 x 2 pole 12 x 3 pole Incoming Terminals 4 x WDU35 + 1 x WPE35 4 x WDU35 + 1 x WPE35 4 x WDU35 + 1 x WPE35 Outgoing Terminals 36 x WDU2.5 + 36 x WPE2.5 36 x WDU2.5 + 18 x WPE2.5 36 x WDU2.5 + 12 x WPE2.5 Product Code DBD170/301 DBD170/182 DBD170/123 For cast aluminium add /AL to product code e.g. DBD150/91/AL. For cast iron add /CI to product code e.g. DBD150/91/CI tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 186 PART 7.0 LIGHTING 7.1 Fluorescent Lighting Fittings Page 189 Single and twin standard and emergency luminaires approved to ‘d’, ‘de’, ‘edq’ and ‘nA’ for lamps ranging from 8 Watts to 58 Watts 7.2 High Intensity Discharge Lighting Fittings Page 199 Wellglass* and floodlight luminaires approved to ‘d*’, ‘de’ and ‘nR’ for all types of high intensity discharge lamps ranging from 70 Watts to 400 Watts 7.3 Walkway and Portable Lighting Page 205 Bulkhead and hand lamp EEx de luminaires ranging from 13 to 60 Watts * 187 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com These products will be introduced later in 2006 and are included for advanced notice only tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 188 Fluorescent Lighting Type Calstar - EEx d Fluorescent Fitting for 18 to 58 Watt Lamps PART 7.1 FLUORESCENT LIGHTING FITTINGS EEx d IIB, IIC Zones 1,2,21,22 T5, T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIB and IIC (T6) -20˚C to + 40˚C (T5) -20˚C to + 55˚C (T4) -20˚C to + 70˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1107 GOST’R’ POCC GB. гБ05. B01132 IP67 to EN60529:1992 ENCLOSURE SPECIFICATION Type Calstar – EEx d Single and Twin Fluorescent Fittings for 18-58W lamps Type Calstar – EEx de Single and Twin Emergency Fluorescent Fittings for 18-58W lamps Type Calstar Type E152 Page 194 Page 195 – EEx nA Single and Twin Fluorescent Fittings for 18-58W Lamps Type N162 Cover fixing Gasket Earthing Mounting ENTRY SPECIFICATION 1 x 20mm EEx d threaded hole at A and B. Both are fitted with an EEx d stopping plug. – EEx edq Single, Twin and Triple Fluorescent Recessed Fittings for 18-58W lamps Type N161 Page 193 – EEx edq Single and Twin Fluorescent Emergency Fittings for 18-36W lamps Type E 181 Page 192 Finish All cast metal parts – light metal alloy Overtube – borosilicate glass Reflector – 1.2mm mild steel Cast metal parts - Epoxy powder coat RAL7032 Reflector – epoxy powder coat – white M6 allen head stainless steel screws Nitrile O ring Internal and external earths Two stainless steel removable mounting brackets supplied as standard – EEx edq Single and Twin Fluorescent Fittings for 18-58W lamps Type E148 Page 191 – EEx de single Emergency Exit Fluorescent Fittings for 8W Lamps Material Page 190 Page 196 – EEx nA Single and Twin Fluorescent Emergency Fittings for 18-36W Lamps ELECTRICAL SPECIFICATION Control gear Page 197 Operating voltage Operating current Power factor Terminals Lamps High frequency electronic ballast complying with all European standards relating to safety, operation and EMC (Immunity) 220 – 254 Volts 50/60Hz 0.5 Amps max 0.98 2.5mm sq. connection block. Suitable for through wiring Bi-pin Flourescent tube 26mm T8 or 25mm T12 All Dimensions in mm ORDERING INFORMATION Wattage 1 x 18 watts 2 x 18 watts 1 x 36 watts 2 x 36 watts 1 x 58 watts 2 x 58 watts GAS GROUPS IIA AND IIB Length Weight 600mm 5.0kg 600mm 5.2kg 7.0kg 1200mm 7.2kg 1200mm 8.0kg 1500mm 8.3kg 1500mm Product Code 500/0103 500/0121 500/0109 500/0127 500/0115 500/0133 Wattage 1 x 18 watts 2 x 18 watts 1 x 36 watts 2 x 36 watts 1 x 58 watts 2 x 58 watts GAS GROUPS IIC Length Weight 5.0kg 600mm 5.2kg 600mm 7.0kg 1200mm 7.2kg 1200mm 8.0kg 1500mm 8.3kg 1500mm Product Code 600/0103 600/0121 600/0109 600/0127 600/0115 600/0133 Notes: Add WG to part number if wire guard required 189 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 190 Fluorescent Lighting Fluorescent Lighting Type Calstar - EEx de Emergancy Fluorescent Fitting for 18 to 58 Watt Lamps Type Calstar - EEx de Emergency Fluorescent Exit Fitting for 8 Watt Lamps EEx de IIB, IIC Zones 1,2,21,22 T5, T6 Group II Cat 2 ATEX/GOST Area classification Certification No. Ingress protection II 2 GD EEx de IIB and IIC (T6) -20˚C to + 40˚C (T5) -20˚C to + 55˚C (T4) -20˚C to + 70˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA02ATEX1107 GOST’R’ POCC GB. гБ05. B01132 IP67 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection ENCLOSURE SPECIFICATION Material Finish Cover fixing Gasket Earthing Battery Housing Mounting Zones 1,2,21,22 T5, T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class EEx de IIC II 2 GD EEx de IIC (T6) -20˚C to +40˚C (T5) -20˚C to + 55˚C Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1107 GOST’R’ POCC GB. гБ 05. B01132 IP67 to EN60529:1992 ENCLOSURE SPECIFICATION All cast metal parts – light metal alloy Overtube – borosilicate glass Reflector – 1.2mm mild steel Cast metal parts - Epoxy powder coat RAL7032 Reflector – epoxy powder coat – white M6 allen head stainless steel screws Nitrile O ring Internal and external earths Aluminium tube with EEx e glands Two stainless steel removable mounting brackets supplied as standard Material Finish Cover fixing Gasket Earthing Battery Tube Mounting ENTRY SPECIFICATION Pictograms supplied as standard All cast metal parts – light metal alloy Overtube – borosilicate glass Reflector – 1.2mm mild steel Cast metal parts - Epoxy powder coat RAL7032 Reflector – epoxy powder coat – white M6 allen head stainless steel screws Nitrile O ring Internal and external earths Aluminium tube with EEx e glands Two stainless steel removable mounting brackets supplied as standard ENTRY SPECIFICATION 1 x 20mm EEx d threaded hole at A and B One entry is used for the battery and the other is fitted with an EEx d stopping plug 1 x 20mm EEx d threaded hole at A and B One entry is used for the battery and the other is fitted with an EEx d stopping plug. ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Control gear High frequency electronic ballast and emergency module complying with all European standards relating to safety, operation and EMC (Immunity) 220 – 254 Volts 50/60Hz 0.5 Amps max 0.98 Maintained and non-maintained 3 hours in both modes 24 hours from fully discharged state Protection against deep discharge and reverse battery polarity 2.5mm sq. connection block suitable for through wiring Bi-pin Flourescent tube 26mm T8, 25mm T12 Operating voltage Operating current Power factor Emergency operation Emergency operating time Recharge time Protection Terminals Lamp Control gear High frequency electronic ballast complying with all European standards relating to safety, operation and EMC (Immunity) Operating voltage 220 – 254 Volts 50/60Hz Operating current 0.5 Amps max Power factor 0.98 Emergency operation Maintained and non–maintained Emergency operating time 3 hours in both modes Recharge time 24 hours from fully discharged state Terminals 2.5mm sq. connection block suitable for through wiring Lamp Bi-Pin fluorescent tubes, T5 A set of 3 pictograms as indicated opposite are supplied Pictograms as standard All Dimensions in mm All Dimensions in mm ORDERING INFORMATION Wattage 1 x 18 watts 2 x 18 watts 1 x 36 watts 2 x 36 watts 1 x 58 watts 2 x 58 watts GAS GROUPS IIA AND IIB Length Weight 600mm 6.0kg 600mm 6.2kg 8.0kg 1200mm 8.2kg 1200mm 9.0kg 1500mm 9.3kg 1500mm Product Code 550/0103 550/0121 550/0109 550/0127 550/0115 550/0133 Wattage 1 x 18 watts 2 x 18 watts 1 x 36 watts 2 x 36 watts 1 x 58 watts 2 x 58 watts GAS GROUPS IIC Length Weight 6.0kg 600mm 6.2kg 600mm 8.0kg 1200mm 8.2kg 1200mm 9.0kg 1500mm 9.3kg 1500mm Product Code 650/0103 650/0121 650/0109 650/0127 650/0115 650/0133 ORDERING INFORMATION Wattage 1 x 8 watts Length 300mm Weight 4.0kg Product Code 650/0211 Note: Fitting complete with lamp Note: Add WG to part number if wire guard required 191 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 192 Fluorescent Lighting Fluorescent Lighting Type E152 - EEx edq Fluorescent Fitting for 18 to 58 Watt Lamps Type E148 - EEx edq Emergency Fluorescent Fitting for 18 to 36 Watt Lamps EEx edq IIC Zones 1,2,21,22 T4 Group II Cat 2 ATEX HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection EEx edq IIC Zones 1,2,21,22 T4 Group II Cat 2 ATEX HAZARDOUS AREA SPECIFICATION II 2 G, II 2 D T80C EEx edq IIC T4 (T4) -20˚C to +60˚C (T4) -20˚C to +50˚C for 1 x 58 Watt and 2 x 58 Watt Zones 1,2,21,22 . Groups IIA, IIB, IIC PTB 97 ATEX2223,2224,2225 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx edq IIC T4 (T4) -20˚C to +55˚C Zones 1,2,21,22. Groups IIA, IIB, IIC PTB05 ATEX2066 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION ENCLOSURE SPECIFICATION Material Material Diffuser fixing Isolating switch Gasket Mounting Body – Glass reinforced polyester Diffuser – polycarbonate Reflector – glass reinforced polyester Hinged with central locking, key provided as standard Isolates all poles of power supply when luminaire is opened EPDM Brackets as required fixed to body through bushes moulded into body. See drawing Diffuser fixing Gasket Mounting ENTRY SPECIFICATION ENTRY SPECIFICATION 1 x 20mm entry at A, B and C. Supplied with 2 EEx e cable glands and 1 EEx e stopping plug 1 x 20mm entry at A, B and C. Supplied with 2 EEx e cable glands and 1 EEx e stopping plug. ELECTRICAL SPECIFICATION Control gear Operating voltage Frequency Operating current Power factor Terminals Lamp Body and Battery housing– Glass reinforced polyester Battery housing - separate Diffuser – polycarbonate Reflector – glass reinforced polyester Hinged with central locking. Key supplied as standard EDPM Brackets as required fixed to body through bushes moulded into body. See drawing ELECTRICAL SPECIFICATION EEx edq approved high frequency electronic ballast 220 – 254 Volts AC, DC 0 or 50/60Hz 0.5 Amps max 0.98 L1 + N +PE up to 6mm sq max Bi-pin flourescent tubes 26mm T8 and 38mm T12 Control gear Operating voltage Operating current Power factor Emergency operation Emergency operating time Battery Recharge time Lamp Terminals All Dimensions in mm EEx edq approved high frequency electronic ballast and emergency module 220 – 254 Volts 50/60Hz 0.5 Amps 0.98 Maintained and non–maintained 3 hours in both modes NiCd 24 hours from fully discharged state Bi-pin Flourescent tube 25mm T8 Li = N =PE 6mm sq max, for through wiring 6x2.5 mm sq. max. All Dimensions in mm ORDERING INFORMATION Wattage 1 x 18 watts 2 x 18 watts 1 x 36 watts 2 x 36 watts 1 x 58 watts 2 x 58 watts Mounting Accessories Hook (pair) Bracket (pair) Spare Key 193 Length 600mm 600mm 1200mm 1200mm 1500mm 1500mm Weight 7.5kg 8.0kg 10.2kg 10.7kg 13.5kg 14.0kg Product Code E15221 E15222 E15241 E15242 E15261 E15262 ORDERING INFORMATION Wattage 2 x 18 watts 2 x 18 watts 2 x 36 watts 2 x 36 watts Mounting Accessories Hook (pair) Bracket (pair) Spare Key H15 B15 KIS tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Emergency Duration 1 hour 3 hour 1 hour 3 hour Length 600mm 600mm 1200mm 1200mm Weight 8.9kg 9.3kg 12.6kg 13.0kg Product Code E1482214 E1482237 E1484214 E1484237 H15 B15 KIS tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 194 Flourescent Lighting Fluorescent Lighting Type E181 - EEx edq Recessed Fluorescent Fitting for 18 to 58 Watt Lamps Type N161 - EEx nA Fluorescent Fitting for 18 to 58 Watt Lamps EEx edq IIC Zones 1,2,21,22 T4, T5 Group II Cat 2 ATEX HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection EEx nA IIC Zones 2,22 T4 Group II Cat 3 ATEX HAZARDOUS AREA SPECIFICATION II 2 G, II 2 D T5 (75C) EEx edq IIC T4 (T4) -20˚C to + 50˚C for 1 or 2 lamp options (T4) -20˚C to + 40˚C for 3 lamp options Zones 1,2,21,22 . Groups IIA, IIB, IIC IBExU 02 ATEX1018 IP65 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 3 G, II 3 D T80C – 100C EEx nA IIC T4 -20˚C to +40˚C Zones 2,22. Groups IIA, IIB, IIC TUV 00ATEX1541 IP65 to EN60529:1992 ENCLOSURE SPECIFICATION ENCLOSURE SPECIFICATION Material Diffuser fixing Gasket Isolating Switch Mounting Material Body – Powder coated mild steel Diffuser – Toughened glass with hinge Reflector – Powder coated mild steel Hinged with central locking EDMP Isolating power supply when luminaire is opened, with indicator Brackets as required fixed to body through bushes fitted into body. See drawing Diffuser fixing Gasket Earthing Mounting Body – Glass reinforced polyester Diffuser – polycarbonate Reflector – glass reinforced polyester Plastic clips. SS clips on request EPDM Internal There are closed knock-outs in the housing for direct ceiling mounting Sealing gaskets are supplied as standard For mounting accessories see below ENTRY SPECIFICATION ENTRY SPECIFICATION 1 x 20mm entry at A, B and C. Supplied with 2 EEx e cable glands and 1 EEx e stopping plug. 1 x 20mm entry at A, B and C. Supplied with 2 EEx e cable glands and 1 EEx e stopping plug ELECTRICAL SPECIFICATION Control gear Operating voltage Frequency Operating current Power factor Terminals ELECTRICAL SPECIFICATION Control gear Operating voltage Frequency Operating current Power factor Terminals Lamp EEx edq approved high frequency electronic ballast 220 – 254 volts AC/DC 50/60Hz or 0 0.5 Amps max 0.98 Li + N +PE 6mm sq max Bi-Pin fluorescent tubes, 26mm T8 and 38mm T12 Lamp High frequency electronic ballast 220 – 254 Volts AC, DC 0 or 50/60Hz 0.5 Amps max 0.98 2x2.5mm sq terminals.as standard For through wiring up to 5x2.5mm sq terminals Bi-Pin fluorescent tubes, 26mm T8 All Dimensions in mm All Dimensions in mm ORDERING INFORMATION ORDERING INFORMATION Lamp(s) 1 x 18 watts 2 x 18 watts 3 x 18 watts Mounting Accessories Hook (pair) Bracket (pair) Frame 195 Weight 11kg 11kg 13kg Product Code E18121 E18122 E18123 Lamp(s) 1 x 36 watts 2 x 36 watts 3 x 36 watts Weight 19kg 19kg 21kg Product Code E18141 E18142 E18143 Lamp(s) 1 x 58 watts 2 x 58 watts 3 x 58 watts Weight 22kg 22kg 24kg Product Code E18161 E18162 E18163 Wattage 1 x 18 watts 2 x 18 watts 1 x 36 watts 2 x 36 watts 1 x 58 watts 2 x 58 watts Mounting Accessories Hook (pair) Bracket (pair) E15 E15B E15F tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Length 600mm 600mm 1200mm 1200mm 1500mm 1500mm Weight 2.2kg 2.9kg 4.3kg 2.9kg 5.1kg 6.3kg Temp. Class T4 T4 T4 T4 T4 T4 Product Code N16121 N16122 N16141 N16142 N16161 N16162 N15 N15B tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 196 Fluorescent Lighting Type N162 - EEx nA Emergency Fluorescent Fitting for 18 to 36 Watt Lamps EEx nA Zones 2,22 T4 Group II Cat 3 ATEX HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 3 G EEx nA T4 0˚C to + 40˚C Zones 2,22. Groups IIA, IIB, IIC TUV 00ATEX1541 IP65 to EN60529:1992 ENCLOSURE SPECIFICATION Material Diffuser fixing Gasket Earthing Mounting Body – Glass reinforced polyester Diffuser – polycarbonate Reflector – glass reinforced polyester Plastic clips. SS clips on request EPDM Internal There are closed knock-outs in the housing for direct ceiling mounting Sealing gaskets are supplied as standard For mounting accessories see below ENTRY SPECIFICATION 1 x 20mm entry at A, B and C. Supplied with 2 EEx e cable glands and 1 EEx e stopping plug ELECTRICAL SPECIFICATION Control gear Operating voltage Frequency Operating current Power factor Terminals Lamp Emergency Gear Battery Protection Visual monitoring Recharging time High frequency electronic ballast 220 – 254 Volts AC, DC 0 or 50/60Hz 0.5 Amps max 0.98 2x2.5mm sq terminals.as standard For through wiring up to 5x2.5mm sq terminals Bi-Pin fluorescent tubes, 26mm T8 3 hour operation Maintained or non-maintained operation Single lamp version – maintained operation as standard Twin lamp version – maintained operation, two lamps in mains operation, one in emergency operation NiCd type Deep discharge protection Battery status shown by LED 24 hours All Dimensions in mm ORDERING INFORMATION Wattage 1 x 18 watts 2 x 18 watts 1 x 36 watts 2 x 36 watts Mounting Accessories Hook (pair) Bracket (pair) 197 Length 600mm 600mm 1200mm 1200mm Weight 4.2kg 4.7kg 6.9kg 7.4kg Temp. Class T4 T4 T4 T4 Product Code N16221 N16222 N16241 N16242 N15 N15B tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 198 Wellglass Lighting Type ORBeX - EEx de Wellglass for HID Lamps to 250 Watts PART 7.2 HIGH INTENSITY DISCHARGE FITTINGS EEx de IIC Zones 1,2,21,22 T4, T5 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 G EEx de IIC (T5) -20˚C to +40˚C (T4) -20˚C to +50˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC TBA IP66/67 to EN60529:1992 ENCLOSURE SPECIFICATION Type ORBeX – EEx de Well Glass for HID Lamps to 250 Watts Page 200 Dimensions Material Type HORIZON - EEx de Floodlight for HID Lamps to 400 Watts Type FLN150 – Ex nR Floodlight for HID Lamps to 150 Watts Type FLN250 Page 202 – Ex nR Floodlight for HID Lamps to 250 Watts Type FLN400 Page 201 Page 203 – Ex nR Floodlight for HID Lamps to 400 Watts Finish Weight Glass dome fixing Gasket Earthing Mounting Wiring Fastenings 320 diam. x 425mm All cast metal parts – light metal alloy Glass dome – borosilicate glass Reflector – high purity aluminium Cast metal parts - Epoxy powder coat RAL7032 16.3 Kg Machined thread on housing and dome collar Nitrile O ring Internal and external earths Two x M10 eye bolts, ceiling bracket or swivel bracket Direct into EEx e wiring box Stainless steel ENTRY SPECIFICATION Page 203 1 x 20mm EEx e threaded entry at A and B. Entry is fitted with an EEx e stopping plug. ELECTRICAL SPECIFICATION Control gear Operating voltage Operating current Power factor Terminals Lampholder Lamps Magnetic choke with associated electronic igniter 220 – 254 Volts 50/60Hz 1.2 Amps 0.98 with pf correction capacitor L1 + N + PE. 6.0mm max E27 or E40 High pressure Sodium, Metal Halide and Mercury Vapour lamps All Dimensions in mm ORDERING INFORMATION Temp. Class T5 T4 T5 T5 T4 T5 T5 T4 Lamp 125 watt mercury 250 watt mercury 100 watt metal halide 150 watt metal halide 250 watt metal halide 100 watt sodium 150 watt sodium 250 watt sodium MOUNTING DEVICES 1 pair x 10mm eye bolts in galvanised steel Ceiling Bracket Swivel Bracket in galvanised steel 199 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com ORB/EB ORB/CB ORB/SB Accessories External reflector Protective guard tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code ORB/125HM ORB/250HM ORB/100HI ORB/150HI ORB/250HI ORB/100HS ORB/150HS ORB/250HS ORB/ER ORB/WG 200 Floodlighting Floodlighting Type HORIZON - EEx de Floodlight for HID Lamps to 400 Watts Type FLN150 - Ex nR Floodlight for HID Lamps to 150 Watts EEx ed IIC Zones 1,2,21,22 T3, T4 Group II Cat 1,2,3 ATEX/GOST Zones 2,22 T5 Group II Cat 3 ATEX/GOST HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Ex nR II II 2 GD EEx de IIC To be advised Zones 1,2,21,22. Groups IIA, IIB, IIC TBA IP67 to EN60529:1991 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 3 GD Ex nR II T5 -40˚C to +48˚C. lamp upright T5 -40˚C to +41˚C. lamp up T5 -40˚C to +43˚C. lamp down Zones 2,22. SIRA 05ATEX4057 IP65 to EN60529:1992 ENCLOSURE SPECIFICATION ENCLOSURE SPECIFICATION Material All cast metal parts – light metal alloy Glass – borosilicate glass Reflector – pure aluminium Cast metal parts - Epoxy powder coat RAL7032 25.0Kg Permanently fixed into frame M6 allen head stainless steel screws Lockable screw for lamping Internal and external earths Stainless steel swivel bracket Stainless steel Finish Weight Glass Frame fixing Lamping Earthing Mounting Fastenings Dimensions Material Finish Cover fixing Weight Gasket Earthing Mounting ENTRY SPECIFICATION 1 x 20mm EEx e threaded entry at A and B Each entry is fitted with an EEx d stopping plug 150 Watts – 440mm x 380mm x 190mm Body and cover. Aluminium 3.0 mm or CR4 mild steel1.5mm Glass – Toughened glass Reflector – Smooth polished or hammer aluminium Epoxy powder coated - black Fully detachable hinged cover with captive M6 stainless steel Hexagon head slotted screws 15 kgs One piece silicon rubber Internal and external earths 5mm stainless steel stirrup bracket ENTRY SPECIFICATION 2 x 20mm entries at A as standard ELECTRICAL SPECIFICATION Control gear Operating voltage Operating current Power factor Terminals Lampholder Lamps Magnetic choke with associated electronic igniter 220 – 254 Volts 50/60Hz 1.8 Amps max 0.98 with pf correction capacitor L1 + N + PE. 6.0mm max E40 High pressure Sodium, Metal Halide and Mercury Vapour lamps ELECTRICAL SPECIFICATION All Dimensions in mm Control gear Operating voltage Operating current Power factor Terminals Lampholder Lamps Magnetic choke with associated electronic igniter 220 – 254 Volts 50/60Hz 0.6 Amps 0.98 with pf correction capacitor MK6/6 E40 Tubular High Pressure Sodium and Metal Halide lamps All Dimensions in mm ORDERING INFORMATION Lamp 125 watt mercury 250 watt mercury 400 watt mercury 150 watt metal halide 250 watt metal halide 400 watt metal halide 150 watt sodium 250 watt sodium 400 watt sodium 201 ORDERING INFORMATION Temp. Class T4 T3 T3 T4 T3 T3 T4 T3 T3 Product Code HZ125/HM HZ250/HM HZ400/HM HZ150/HI HZ250/HI HZ400/HI HZ150/HS HZ250/HS HZ400/HS tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Lamp 150 watts metal halide 150 watts high pressure sodium Product Code FLN150HI FLN150HS tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 202 Floodlighting Type FLN250/400 - Ex nR Floodlight for 250 and 400 Watt HID Lamps Ex nR II Zones 2,22 T3 Group II Cat 3 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 3 GD Ex nR II 250 Watts T3 -40˚C to + 50˚C lamp upright T3 - 40˚C to + 48˚C lamp down T3 - 40˚C to + 53˚C lamp up 400 Watts T3 -40˚C to + 45˚C lamp upright T3 - 40˚C to + 48˚C lamp down T3 - 40˚C to + 47˚C lamp up Zones 2, 22 SIRA 05ATEX4057 IP65 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Cover fixing Weight Gasket Earthing Mounting 575mm x 505mm x 190mm Body and cover. Aluminium 3.0mm or CR4 mild steel 1.5mm Glass – Toughened glass Reflector – Smooth polished or hammer aluminium Epoxy powder coated - black Fully detachable hinged cover with captive M6 stainless steel Hexagon head slotted screws 25Kg One piece silicon rubber Internal and external earths 5mm stainless steel stirrup bracket ENTRY SPECIFICATION 2 x 20mm entries at A as standard ELECTRICAL SPECIFICATION Control gear Operating voltage Operating current Power factor Terminals Lampholder Lamps Magnetic choke with associated electronic igniter 220 – 254 Volts 50/60Hz 1.5 Amps 0.98 with pf correction capacitor MK6/6 E40 Tubular High Pressure Sodium, Metal Halide lamps All Dimensions in mm ORDERING INFORMATION Lamp 250 watts metal halide 400 watts metal halide 250 watts high pressure sodium 400 watts high pressure sodium 203 Product Code FLN250HI FLN400HI FLN250HS FLN400HS tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 204 Bulkhead Lighting Type 300 - EEx de Bulkhead Fitting for 13 Watt Compact Fluorescent and 60 watt GLS PART 7.3 WALKWAY AND PORTABLE LIGHTING EEx de IIC Type E8310 – EEx de Bulk Head Luminaires for 13w Compact Fluorescent and 60w GLS Lamps Page 206 – EEx de Handlamp for 60w Page 207 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Type 300 Zones 1,2,21,22 II 2 GD EEx de IIC Compact fluorescent vertically mounted (T5) - 20˚C to +54˚C Compact fluorescent horizontally mounted (T6) -20˚C to + 49˚C GLS lamp vertically mounted (T4) -20˚C to + 41˚C GLS lamp horizontally mounted (T3) -20˚C to + 66˚C Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA02ATEX1107 GOST’R’ POCC GB. гБ05. B01132 IP67 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Earthing Mounting 303mm x 160mm All cast metal parts – light metal alloy Overtube – borosilicate glass Reflector – 1.2mm mild steel Cast metal parts - Epoxy powder coat RAL7032 Reflector – epoxy powder coat – white 2.5 Kg M6 allen head stainless steel screws Nitrile O ring Internal earths Two stainless steel mounting brackets supplied as standard ENTRY SPECIFICATION 1 x 20mm EEx e threaded entry at A and B. Each entry is fitted with an EEx e stopping plug. ELECTRICAL SPECIFICATION Control gear Operating voltage Operating current Power factor Terminals Lamp High frequency electronic ballast 220 – 254 Volts 50/60Hz Compact fluorescent 0.08 Amps, GLS 0.25 Amps 0.98 2.5mm sq. connection block 13 Watt compact fluorescent or 60 Watt GLS All Dimensions in mm ORDERING INFORMATION Lamp(s) 1 x 13 watts compact fluorescent 1 x 60 watts GLS 205 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code 300/CLF 300/GLS tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 206 Handlamp Type E8310 - EEx ed Handlamp for 60 Watt EEx ed II Zones 1,2,21,22 T3, T4 Group II Cat 2 ATEX HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx ed II 60 Watts. T4 -20˚C to + 40˚C Zones 1,2,21,22 PTB01ATEX2144 IP65 to EN60529:1992 SPECIFICATION Dimensions Material Weight Wire gaurd 416mm x 141mm Rubber handle with glass globe 2.3Kg Standard ELECTRICAL SPECIFICATION Voltage 220V - 230V AC/DC 120V AC/DC 24V - 42V AC/DC (T2) 416 ø141 All Dimensions in mm ORDERING INFORMATION Lamp 60 watts OSRAM 207 Product Code E8310 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 208 PART 8.0 PLUGS AND SOCKETS 209 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Type DXN – EEx de Switched Plugs and Sockets to 63 Amps Page 211 Type BX – EEx d Metal clad Plugs and Sockets to 32 Amps Page 212 Type SPXL – EEx de Multi Socket Outlets in Stainless steel Page 213 Type SPGL – EEx de Multi Socket Outlets in Glass Reinforced Polyester Page 214 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 210 Plugs and Sockets Plugs and Sockets Type DXN - EEx de Switched Plugs and Sockets to 63 Amps Type BX - EEx d Metal Clad Plugs and Switched Sockets to 230 Amps EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification Nos Ingress protection EEx d IIB Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION II 2 GD EEx de II T6 T6 -40˚C to +40˚C for maximum current rating of 60 Amps T5 -40˚C to +40˚C for 63 Amps Zones 1,2,21,22. Groups IIA, IIB, IIC 20 Amps LCIE 00ATEX6010X 32 Amps LCIE 99ATEX6027X 63 Amps LCIE 02ATEX 6029X IP66,67 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Apparatus standard Certification No. Ingress protection II 2 GD EEx d IIB T6 -20˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB EN 50014:1998 and EN 50018: 1995 SIRA02ATEX1332 GOST’R’ POCC GB. гБ05. B01132 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION ENCLOSURE SPECIFICATION Casing Material Casing Finish Contacts Security Mounting Dimensions Material Finish Glass reinforced polyester Moulded black Silver nickel butt type contacts with added metallic braid Plug is detached only after the circuit is broken within the de enclosure Mounting boxes are provided to facilitate wall mounting of the socket Weight Cover fixing Earthing Security ENTRY SPECIFICATION Mounting Entry is via integral 20mm EEx e glands as standard, 25mm (25A), 32mm (32A), 40mm (63A) 220mm x 185mm x 161mm Cast iron to 180BSI1452:1997 and brass Cast iron components - Zinc rich epoxy powder primer and epoxy powder top coat Brass components – machined self colour 10.5 Kg M6 allen head stainless steel screws Internal and external EEx e brass clamps on base Earth on cover Mechanical locking of plug in socket Plug cannot be removed when switch is in the ON position Two steel mounting straps with 8mm fixing holes ENTRY SPECIFICATION 1 x 20mm EEx d threaded hole at A,B and C Each entry is fitted with an EEx d stopping plug. 25mm entries are available as an option ELECTRICAL SPECIFICATION Voltage Volts 380-440 380-440 Current AC21A (A) 20 32 Power AC23A(Kw) 5.5 11 AC-3(Kw) 3.7 7.5 Conductor Size mmsq. Max. 2.5 6.0 All Dimensions in mm ORDERING INFORMATION Current Rating 20 Amps 20 Amps 20 Amps 20 Amps 32 Amps 32 Amps 32 Amps 32 Amps 63 Amps 63 Amps 63 Amps 63 Amps 211 Pin Configuration 2p spne 3pe 3pne 2p spne 3pe 3pne 2p spne 3pe 3pne voltage 24v 240v 400v 400v 24v 240v 400v 400v 24v 240v 400v 400v Plug with handle, socket with wall box DXN1A DXN1B DXN1C DXN1D DXN3A DXN3B DXN3C DXN3D DXN6A DXN6B DXN6C DXN6D Plug with handle, socket with handle DXN1E DXN1F DXN1G DXN1H DXN3E DXN3F DXN3G DXN3H DXN6E DXN6F DXN6G DXN6H tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com ORDERING INFORMATION Current rating 20 Amps 32 Amps Switch Position on-off on-off tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code BX203 BX323 212 Plugs and Sockets Plugs and Sockets Type SPXL - EEx de Multi Socket Outlet in Stainless Steel Enclosure Type SPGL - EEx de Multi Socket Outlet in Glass Reinforced Polyester Enclosure EEx de IIC Zones 1,2,21,22 T5, T6 Group II Cat 2 ATEX HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of Protection Temperature class Certification No. Ingresss Protection Finish Cover Fixing Gasket Earthing Security Entries Mounting Zones 1,2,21,22 T6 Group II Cat 2 ATEX HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx de IIC T6 -40˚C to + 40˚C for operating current of 60 Amps SIRA99ATEX3199X IP66,67 To EN60529:1992 II 2 GD EEx de II T6 -40˚C to + 40˚C for operating current of 60 Amps Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA99ATEX3200X IP66 to EN60529:1992 ENCLOSURE SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material EEx de IIC Dimensions As specified Base and Cover 1.5mm 316L (1.4404) Stainless steel Gland Plates 2.5mm 316L (1.4004) stainless steel Electropolished Fully detachable hinged cover with captive M6 stainless steel hexagon slotted screws One piece fire resistant closed cell neoprene 10mm brass internal/external earth stud as standard Optional earth stud welded to cover and gland plates Padlockable Hasp Via gland plates or direct through body External lugs with 10mm clearance holes 255mm x 250mm x 120mm 400mm x 405mm x 120mm Carbon loaded anti-static Glass reinforced polyester UL94/V0 Moulded black M6 allen head captive stainless steel screws. Optional hinges Silicon rubber Optional 6mm external/internal Internal earth stud Optional internal earth continuity plate in galvanised steel, brass or stainless steel Through 6.5 mm clearance holes moulded into base Material Finish Cover fixing Gasket Earthing Mounting ELECTRICAL SPECIFICATION One or two DXN Type sockets on each of 3 sides of the enclosure. Socket Type ELECTRICAL SPECIFICATION One or two DXN Type sockets on each of 3 sides of the enclosure Socket Type DXN1 DXN3 DXN6 Operating Voltage Volts 500 750 750 DXN1 DXN3 DXN6 Operating Current Amps 20 32 60 Operating Voltage Volts 500 750 750 Operating Current Amps 20 32 60 Dimensions to specification ORDERING INFORMATION ORDERING INFORMATION Ordering is subject to customer specification. The size of the enclosure will depend on the number of sockets specified. Please consult Walsall sales for a design and quotation that will form the basis for the order. 213 Dimensions to specification tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Ordering is subject to customer specification. The size of the enclosure will depend on the number of sockets specified. Please consult Walsall sales for a design and quotation that will form the basis for the order. tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 214 PART 9.0 EMERGENCY SHUTDOWN AND SIGNALLING EQUIPMENT A comprehensive range of high specification fire alarms, Xenon beacons, Sounders and Loud speakers, status/indicator lamps, the majority of which use glass reinforced polyester enclosures. Type E0302 – EEx de Manual Call Point with Break Glass in a glass reinforced polyester enclosure Page 217 Type E0303 – EEx de Manual Call Point with Switch in a glass reinforced polyester enclosure Type E0304 – EEx de Manual Call Point with Pushbutton in a glass reinforced polyester enclosure Page 219 Type E0301 – EEx de Manual Call Point with Break Glass in a cast iron enclosure Page 220 Type BU – EEx de Xenon beacon* Page 221 Type SU – EEx de Sounder* Page 222 Type BSU – EEx de Combined beacon and sounder* Page 223 Type LU – EEx de Loud speaker* Page 224 Type E501 – EEx d Single Status/Indicator Lamp in a cast iron enclosure Page 225 Type E502 – EEx d Double Status/Indicator Lamp in a cast iron enclosure Page 226 * 215 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Page 218 These products will be introduced later in 2006 and are included for advanced notice only tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 216 Emergency Shutdown and Signalling Equipment Type E0302 - EEx de IIC Manual Call point with Break Glass in GRP EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Apparatus standard Certification No Ingress protection EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION II 2 GD EEx de IIC T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC EN 50014:1998 and EN 50019: 1995 SIRA03ATEX3293 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Apparatus standard Certification No Ingress protection ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Other plastic components Operator flamepath Glass Earthing Mounting Emergency Shutdown and Signalling Equipment Type E0303 - EEx de IIC Manual Call point with Switch in GRP II 2 GD EEx de IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC EN 50014:1998 and EN 50019: 1995 SIRA03ATEX3293 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION 125mm x 110mm x 105mm Glass reinforced polyester Moulded red 1.2Kg M6 allen head stainless steel screws 1.2mm one piece solid nitrile rubber Polycarbonate Brass shaft in a brass housing 2.5mm Standard Internal EEx e brass clamps on base Through 10mm holes moulded into base Dimensions Material Finish Weight Cover fixing Gasket Other plastic components Operator flamepath Glass Earthing Mounting ENTRY SPECIFICATION 125mm x 110mm x 105mm Glass reinforced polyester Moulded red 1.2 Kg M6 allen head stainless steel screws 1.2mm one piece solid nitrile rubber Polycarbonate Brass shaft in a brass housing 2.5mm Standard Internal EEx e brass clamps on base Through 10mm holes moulded into base ENTRY SPECIFICATION 1 x 20mm EEx e threaded hole base at A as standard. All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option 1 x 20mm EEx e threaded hole base at A as standard. All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Walsall Contact Block Certification number SIRA03ATEX1269U Voltage Volts 230 - 270 Current Amps 16 Walsall Contact Block Certification number SIRA03ATEX1269U Conductor Size mmsq. Max 2.5 Voltage Volts 230 - 270 When used with monitored fire alarm systems as defined in BS 5839 ‘series’ and /or ‘end of line’ resistors can be incorporated. Maximum allowable resistor power dissipation is 0.5 Watts at 24 Volts. To comply with certification requirements the resistor(s) must be fitted at the time of manufacture. Current Amps 16 Conductor Size mmsq. Max 2.5 When used with monitored fire alarm systems as defined in BS 5839 ‘series’ and /or ‘end of line’ resistors can be incorporated. Maximum allowable resistor power dissipation is 0.5 watts at 24 volts. To comply with certification requirements the resistor(s) must be fitted at the time of manufacture. All Dimensions in mm All Dimensions in mm ORDERING INFORMATION ORDERING INFORMATION Description Fire Alarm without Resistors Fire Alarm with Series Resistors Fire Alarm with end of the line Resistors Fire Alarm with series & end of the line Resistors 217 Switch Position Resistor (s) 1N/O & 1N/C To be specified 1N/O & 1N/C To be specified 1N/O & 1N/C To be specified 1N/O & 1N/C For 25 mm entries add/25 to Product Code e.g. E030212/25 Product Code E030210 E030211 E030212 E030213 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Description Fire Alarm without Resistors Fire Alarm with Series Resistors Fire Alarm with end of the line Resistors Fire Alarm with series & end of the line Resistors Switch Position Resistor (s) 1N/O & 1N/C To be specified 1N/O & 1N/C To be specified 1N/O & 1N/C To be specified 1N/O & 1N/C For 25 mm entries add/25 to Product Code e.g. E030312/25 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code E030310 E030311 E030312 E030313 218 Emergency Shutdown and Signalling Equipment Type E0304 - EEx de IIC Manual Call point with Pushbutton in GRP EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST II 2 GD EEx de IIC T6 -40˚C to + 50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC EN 50014:1998 and EN 50019: 1995 SIRA03ATEX3293 IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Apparatus standard Certification No. Ingress protection ENCLOSURE SPECIFICATION Dimensions Material Finish Weight Cover fixing Gasket Other plastic components Operator flamepath Glass Earthing Mounting EEx d IIC Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Apparatus standard Certification No Ingress protection Emergency Shutdown and Signalling Equipment Type E0301- EEx d IIC Manual Call point with Break Glass in Cast Iron II 2 GD EEx d IIC T6 -40˚C to +50˚C Zones 1,2,21,22. Groups IIA, IIB, IIC EN 50014:1998 and EN 50018: 1995 SIRA02ATEX1307 IP66 to EN60529:1992 ENCLOSURE SPECIFICATION Dimensions Material Finish Colour Weight Cover fixing Gasket Plastic components Operator flamepath Earthing 125mm x 110mm x 105mm Glass reinforced polyester Moulded red 1.2Kg M6 allen head stainless steel screws 1.2mm one piece solid nitrile rubber Polycarbonate Brass shaft in a brass housing 2.5mm Standard Internal EEx e brass clamps on base Through 10mm holes moulded into base Mounting 117mm x 117mm x 143mm Cast iron to 180BSI1452:1997 Zinc rich epoxy powder primer and epoxy powder top coat Red 5.1 Kg M6 allen head stainless steel screws Nitrile O ring Polycarbonate Brass shaft in brass housing. nitrile O ring seal Internal and external EEx e brass clamps on base Earth on cover Through 10mm holes cast into base ENTRY SPECIFICATION ENTRY SPECIFICATION 1 x 20mm EEx e threaded hole base at A as standard All entries are fitted with EEx e stopping plugs as standard 25mm entries are available as an option 1 x 20mm EEx d threaded hole at A and B as standard. All entries are fitted with EEx d stopping plugs as standard 25mm entries are available as an option ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION Walsall Contact Block Certification number SIRA03ATEX1269U Contactors to IEC 60 947 , BS EN 60 947. Voltage Volts 230 - 270 Current Amps 16 Conductor Size mmsq. Max 2.5 Voltage Volts 230-270 414 All Dimensions in mm When used with monitored fire alarm systems as defined in BS 5839 ‘series’ and /or ‘end of line’ resistors can be incorporated. Maximum allowable resistor power dissipation is 0.5 Watts at 24 Volts. To comply with certification requirements the resistor(s) must be fitted at the time of manufacture. Conductor Size mmsq. Max 2.5 2.5 All Dimensions in mm When used with monitored fire alarm systems SERIES and or END OF LINE resistors can be fitted. ORDERING INFORMATION ORDERING INFORMATION Description Switch Position Fire Alarm without Resistors 1N/O & 1N/C Fire Alarm with Series Resistors 1N/O & 1N/C Fire Alarm with end of the line Resistors 1N/O & 1N/C Fire Alarm with series & end of the line Resistors 1N/O & 1N/C Note: For 25 mm entries add/25 to Product Code e.g. E030412/25 219 Current AC15 (A) 3 2 Resistor (s) To be specified To be specified To be specified Product Code E030410 E030411 E030412 E030413 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Description Switch Position Fire Alarm without Resistors 1N/O & 1N/C Fire Alarm with Series Resistors 1N/O & 1N/C Fire Alarm with end of the line Resistors 1N/O & 1N/C Fire Alarm with series & end of the line Resistors 1N/O & 1N/C Note: For 25 mm entries add/25 to Product Code e.g. E030110/25 Resistor (s) To be specified To be specified To be specified tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code E030110 E030111 E030112 E030113 220 Emergency Shutdown and Signalling Equipment Type VANTAGE - EEx de Xenon Beacon EEx de IIC Zones 1,2,21,22 T6 Emergency Shutdown and Signalling Equipment Type VANTAGE - EEx de Sounder Group II Cat 2 ATEX/GOST Voltage Temperature class Material Mounting Initiation Type of Protection System details Lens colour Wire Gaurd Zones 1,2,21,22 5J, 10J, 15J, 20J and 30J (Xenon) customer selectable at installation stage 12V DC, 24V DC, 110V AC, and 240V AC Board voltage selectable at installation stage -55˚C to + 70˚C Glass reinforced polyester Back strap or stirrup mounting Telephone or relay EEx d(e) IIC T6 2GD IP67, IP68 Self mounting PCB with H.A.R.T compatibility Unit monitors flash timings, flash duration, flash intensity and initiation circuit Red, yellow, blue, amber, green, clear Optional Rating Tones Voltage Group II Cat 2 ATEX/GOST Temperature class Material Mounting Type of Protection System details 120dba @ 1 metre Up to 42 tones, customer selectable 12V DC, 24V DC, 110V AC, and 240V AC Board voltage selectable at installation stage. -55˚C to +70˚C Glass reinforced polyester Back strap or stirrup mounting EEx d(e) IIC T6 2GD IP67, 68 Self mounting PCB with H.A.R.T compatibility. Unit monitors tone frequency, tone duration, tone intensity and initiation circuit. Customer selects voltage at installation point, and can alter this rating at any time in the future. The unit has a volume control function which can reduce the dB(A) output accordingly. All Dimensions in mm ORDERING INFORMATION All Dimensions in mm ORDERING INFORMATION Description 5 joule Xenon beacon 10 joule Xenon beacon 15 joule Xenon beacon 20 joule Xenon beacon 25 joule Xenon beacon 30 joule Xenon beacon 221 T6 OUTLINE SPECIFICATION OUTLINE SPECIFICATION Rating EEx de IIC Product Code VB5 VB10 VB15 VB20 VB25 VB30 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Description 105 dB sounder 110 dB sounder 115 dB sounder 120 dB sounder Product Code VS105 VS110 VS115 VS120 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 222 Emergency Shutdown and Signalling Equipment Type VANTAGE - EEx de Combined Sounder and Beacon EEx de IIC Zones 1,2,21,22 T6 Group II Cat 2 Emergency Shutdown and Signalling Equipment Type VANTAGE - EEx de Loud Speaker Unit ATEX/GOST Voltage Temperature class Material Mounting Initiation Type of Protection System details Lens colour Wire Gaurd Zones 1,2,21,22 T6 Group II Cat 2 ATEX/GOST OUTLINE SPECIFICATION BEACON OUTLINE SPECIFICATION Rating EEx de IIC 5J, 10J, 15J, 20J and 30J (Xenon) customer selectable at installation stage 12V DC, 24V DC, 110V AC, and 240V AC Board voltage selectable at installation stage. -55˚C to +70˚C Glass reinforced polyester Back strap or stirrup mounting Telephone or relay EEx d(e) IIC T6 2GD IP67, IP68 Self mounting PCB with H.A.R.T compatibility Unit monitors flash timings, flash duration, flash intensity and initiation circuit Customer selects both voltage and joule rating at installation point, and can alter these ratings at any time in the future. Red, yellow, blue, amber, green, clear Optional Rating Frequency Voltage Temperature class Material Mounting Type of Protection System details 120dB(A @ 25W @ 1 metre. Other tapings via integral transformer @8, 15, 20 Watts 400Hz to 8kHz. 12V DC, 24V DC, 110V AC, and 240V AC Board voltage selectable at installation stage -55˚C to +70˚C Glass reinforced polyester Back strap or stirrup mounting EEx d(e) IIC T6 2GD IP67, 68 Self monitoring PCB with H.A.R.T compatibility Unit monitors initiation circuit Option of 5 customer recordable messages, to suit their own needs and languages (e.g.: “evacuate zone 4” in Polish) SOUNDER OUTLINE SPECIFICATION Raing Tones Voltage Temperature class Material Mounting Type of Protection System details 120dB(A) @ 1 metre Up to 42 tones, customer selectable 12V DC, 24V DC, 110V AC, and 240V AC Board voltage selectable at installation stage -55˚C to +70˚C Glass reinforced polyester Back strap or stirrup mounting EEx d(e) IIC T6 2GD IP67, 68 Self mounting PCB with H.A.R.T compatibility Unit monitors tone frequency, tone duratation, tone intensity and initiation circuit Customer selects voltage at installation point, and can alter this rating at any time in the future The unit has a volume control function which can reduce the dba output accordingly All Dimensions in mm All Dimensions in mm ORDERING INFORMATION ORDERING INFORMATION Note: Customer to specify combination of VB and VS 223 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Description 20watt Loud speaker 25watt Loud speaker Product Code VL20 VL25 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 224 Emergency Shutdown and Signalling Equipment Type E501 - EEx d IIC Single Status/Indicator Lamp EEx d IIC Zones 1,2,21,22 T6 Emergency Shutdown and Signalling Equipment Type E502 E2501D - EEx - EEx d IIC d IIC Double Status Status/Indicator Lamp Lamp Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d IIC T6 -20˚C to + 50˚C (T6) -20˚C to + 85˚C (T5) Zones 1,2,21,22 . Groups IIA, IIB, IIC SIRA02ATEX1058 GOST’R’ POCC GB. гБ05. B01132 IP67 to EN60529:1991 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection Dimensions Material ATEX/GOST II 2 GD EEx d IIC T6 -20˚C to +50˚C (T6) -20˚C to + 85˚C (T5) Zones 1,2,21,22. Groups IIA, IIB, IIC SIRA02ATEX1058 GOST’R’ POCC GB. гБ05. B01132 IP67 to EN60529:1991 ENTRY SPECIFICATION 1 x 20mm EEx d threaded entry at A and B Each entry is fitted with an EEx d stopping plug 1 x 20mm EEx d threaded entry at A. Each entry is fitted with an EEx d stopping plug. ELECTRICAL SPECIFICATION ELECTRICAL SPECIFICATION 220 – 254 Volts 50/60Hz 0.15 Amps max 2 x 2.5mm sq. connection block 15 Watt incandescent BC type Operating voltage Operating current Terminals Lamp Lampholder 220 – 254 Volts 50/60Hz 0.15 Amps max. 2 x 2.5mm sq. connection block 15 Watts incandescent BC type All Dimensions in mm ORDERING INFORMATION Description EEx d miniature wellglass EEx d miniature wellglass EEx d miniature wellglass EEx d miniature wellglass EEx d miniature wellglass Group II Cat 2 Double - 82mm diam x 319mm All cast metal parts – cast iron Overtube – coloured borosilicate glass Cast metal parts - Epoxy powder coat RAL7032 2.0 Kg Threaded junction Nitrile O ring Internal and external earths. Two 8mm holes cast into base Finish Weight Cover fixing Gasket Earthing Mounting ENTRY SPECIFICATION Operating voltage Operating current Terminals Lamp Lampholder T6 ENCLOSURE SPECIFICATION Single - 90mm diam x 159mm All cast metal parts – cast iron Overtube – coloured borosilicate glass Cast metal parts - Epoxy powder coat RAL7032 2.0 Kg Threaded junction Nitrile O ring Internal and external earths Two 8mm holes cast into base Finish Weight Cover fixing Gasket Earthing Mounting Zones 1,2,21,22 HAZARDOUS AREA SPECIFICATION ENCLOSURE SPECIFICATION Dimensions Material EEx d IIC All Dimensions in mm ORDERING INFORMATION Glass Colour White Red Green Blue Amber Product Code E501001 E501002 E501003 E501004 E501005 Description EEx d miniature wellglass EEx d miniature wellglass EEx d miniature wellglass EEx d miniature wellglass EEx d miniature wellglass Glass Colour White - Red Red - Green Green - Amber Blue - White Amber - Red Product Code E502001 E502002 E502003 E502004 E502005 Note: Alternative colour arrangements can be specified by customer. 225 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 208 226 PART 10.0 INSTALLATION ACCESSORIES Type SP – EEx d and EEx e Stopping Plugs Page 229 Type ESKE e - EEx e Cable Glands Page 230 Type ESKE i – EEx i Cable Glands Page 231 Type OSNJ.A2F – EEx d Cable Glands for Non Armoured Cable Page 232 Type WEID.E1WF – EEx d Cable Glands for Single Wire Armoured Cable Page 233 Type BD – EEx e Breather Drains Type WDU and WPE – EEx e and EEx i Wiring Terminals 227 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Page 234 Page 235 228 Installation Accessories Type SP - EEx d and EEx e Stopping Plugs EEx e II and EEx d IIC Zones 1,2,21,22 -20C to +70C Installation Accessories Type ESKE-e - EEx e Increased Safety Cable Glands Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of Protection Temperature Class Area Classification Certification No. Ingress Protection EEx e II Zones 1,2,21,22 -20C to +75C Group II Cat 2 ATEX HAZARDOUS AREA SPECIFICATION II 2 GD EEx d IIC and EEx e II Ta -20˚C to +70˚C Zones 1, 2, 21, 22 Groups IIA, IIB, IIC Sira 04ATEX1365U IP66 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature classi Area classification Certification No. Ingress protection PRODUCT SPECIFICATION II 2 GD EEx e II -20˚C to +75˚C Zones 1, 2,21, 22 PTB05ATEX1068X IP66,67,68 to EN60529:1992 PRODUCT SPECIFICATION EEx e plugs are constructed from polyamide 66 or brass. They comprise of a male threaded shaft with a lipped head which includes a hexagon head recess to allow for fitting and removal. Beneath the head is a nitrile O ring which when compressed provides a seal to the plug. The standard range of threads is M16 to M75 x 1.5, however ET – BS31:1940(1979), NPT – ANSI/ASME:1983, BSP – BS21:1985 and PG – DIN 40430:1971 are also available. Material Gasket Colour Polyamide EDPM Fitting and cap RAL 9005 EEx d plugs are constructed from brass, steel, or stainless steel and have two design options, a threaded shaft with an hexagonal head or a threaded shaft with an hexagonal head recess to allow for fitting and removal of the plug. The standard range of threads is M16 to M75 x 1.5., however ET – BS31:1940(1979), NPT – ANSI/ASME:1983, BSP – BS21:1985 and PG – DIN 40430:1971 are also available. All Dimensions in mm ORDERING INFORMATION Thread M16 M20 M25 M32 M40 M50 M63 M75 Notes 229 ORDERING INFORMATION Type EEx e Polyamide Product Code SPE16 SPE20 SPE25 SPE32 SPE40 SPE50 SPE63 SPE75 1 For Stainless steel add /SS to product code ie. SPD16/SS 2 Thread adaptors are available to order. 3 Other thread types to order Type EEx e Brass Product Code SPE16B SPE20B SPE25B SPE32B SPE40B SPE50B SPE63B SPE75B Type EEx d Brass Product Code Hex Head Product Code Hex Recessed SPD16 SPD20 SPD25 SPD32 SPD40 SPD50 SPD63 SPD75 SPDR16 SPDR20 SPDR25 SPDR32 SPDR40 SPDR50 SPDR63 SPDR75 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Thread size mm M16 x 1.5 M20 x 1.5 M25 x 1.5 M32 x 1.5 M40 x 1.5 M50 x 1.5 M63 x 1.5 Thread Length mm 9 Cable Diam. 4.9 Total Length 31.37 10 10 12 12 14 15 6.13 7.17 13.21 17.28 23.35 31.48 36.45 38.47 42.51 52.65 59.72 64.78 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Product Code ESKE- e 16 ESKE- e 20 ESKE- e 25 ESKE- e 32 ESKE- e 40 ESKE- e 50 ESKE- e 63 230 Installation Accessories Type ESKE-i - EEx i Intrinsically Safe Cable Glands EEx i IIC Zones 1,2,21,22 -20C to +75C Installation Accessories Type OSNJ A2F - EEx d Cable Glands for Non Armoured Cable Group II Cat 2 ATEX HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection EEx d IIC Zones 1,2,21,22 -40C to +100C Group II Cat 2 ATEX HAZARDOUS AREA SPECIFICATION II 2 GD EEx i IIC -20˚C to +75˚C Zones 1,2,21,22 PTB05ATEX1068X IP66,67,68 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection II 2 GD EEx d II C For housings with an internal volume equal to or less than 2000 cubic mm -40˚C to +100˚C Zones 1,2,21,22 PTB02ATEX1460X IP66,67 to EN60529:1992 PRODUCT SPECIFICATION PRODUCT SPECIFICATION Material Gasket Colour Polyamide EDPM Fitting RAL 9005, Cap nut RAL 5012 Material Gasket Brass nickel plated. Stainless steel on request EDPM All Dimensions in mm All Dimensions in mm ORDERING INFORMATION Thread size mm M16 x 1.5 M20 x 1.5 M20 x 1.5 M20x 1.5 M25 x 1.5 M25x 1.5 M32 x 1.5 M32 x 1.5 M40 x 1.5 M40 x 1.5 M50 x 1.5 M50 x 1.5 M63 x 1.5 M63 x 1.5 M75 x 1.5 M75 x 1.5 ORDERING INFORMATION Thread size mm M16 x 1.5 M20 x 1.5 M25 x 1.5 M32 x 1.5 M40 x 1.5 M50 x 1.5 M63 x 1.5 Thread Length mm 9 Cable Diam. 4.9 Total Length 31.37 10 10 12 12 14 15 6.13 7.17 13.21 17.28 23.35 31.48 36.45 38.47 42.51 52.65 59.72 64.78 Product Code ESKE- i 16 ESKE- i 20 ESKE- i 25 ESKE- i 32 ESKE- i 40 ESKE- i 50 ESKE- i 63 Notes 231 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com Thread Length mm 15 Cable Diam. 3.6 15 15 15 15 15 15 15 15 15 15 15 15 15 20 20 6.1-10 10-13 13.1-15 15.1-16 16.1-18 18.1-22 22.1-26 26.1-28 28.1-32 32.1-34 34.1-40 40.1-44 44.1-50 54.1-56 56.1-60 Product Code OSNJ A2F - 16a OSNJ A2F - 16b OSNJ A2F - 20a OSNJ A2F - 20b OSNJ A2F - 25a OSNJ A2F - 25b OSNJ A2F - 32a OSNJ A2F - 32b OSNJ A2F - 40a OSNJ A2F - 40b OSNJ A2F - 50a OSNJ A2F - 50b OSNJ A2F - 63a OSNJ A2F - 63b OSNJ A2F - 75a OSNJ A2F - 75b 1 Available in Stainless Steel add /SS to product code eg. OSNJ A2F -16a/SS 2 Available with earth tag and shroud tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 232 Installation Accessories Type WEID.E1WF - EEx d Cable Glands for Single Wire Armoured Cable EEx d IIC Zones 1,2,21,22 -40C to +100C Group II Cat 2 ATEX HAZARDOUS AREA SPECIFICATION Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection EEx e II Zones 1,2,21,22 -50C to +120C Group II Cat 2 ATEX/GOST HAZARDOUS AREA SPECIFICATION II 2 GD EEx d II C -40˚C to +100˚C Zones 1,2,21,22 Nemko02ATEX500X IP66,67 to EN60529:1992 Marking to 94/9/EC Type of protection Temperature class Area classification Certification No. Ingress protection PRODUCT SPECIFICATION Material Gasket Installation Accessories Type BD - EEx e Breather Drains II 2 GD EEx e II Ta –20˚C to +60˚C (Nylon) Ta -50˚C to +120˚C (Brass) Ta -50˚C to +120˚C (Stainless) Zones 1,2,21,22 Groups IIA, IIB, IIC SIRA 02 ATEX M207 IP66 PRODUCT SPECIFICATION Brass nickel plated. Stainless steel on request EDPM Double compression for inner/outer jacket of cable A drain plug is is manufactured with a range of male threads. To suit most applications, the head of increased diameter enables improved sealing, and with the inclusion of an “O” ring or the use of a washer, will achieve IP66. The head has a series of interconnecting holes, thus enabling drainage to occur. The unique filter is fixed inside the main bore and facilitates a slow drainage and prevents ingress. Fastened by means of an allen key (10mm) the drain plug should be fitted at the lowest point of the enclosure. EEx e breather drains are constructed from brass, nylon or stainless steel. ORDERING INFORMATION Thread M20 M25 1/2” NPT Type EEx e Nylon BDN20 BDN25 BDN1/2 Type EEx e Brass BDB20 BDB25 BDB1/2 Type EEx e Stainless Steel BDS20 BDS25 BDS1/2 All Dimensions in mm ORDERING INFORMATION Thread size mm M16 x 1.5 M20 x 1.5 M20 x 1.5 M25x 1.5 M25 x 1.5 M32x 1.5 M32 x 1.5 M40 x 1.5 M40 x 1.5 M50 x 1.5 M50 x 1.5 M63 x 1.5 M63 x 1.5 M63 x 1.5 M75 x 1.5 M75 x 1.5 Notes 233 Cable Diam. mm 8-15.1 Cable Diam. Below cable sheath mm 5-11 13-17.5 17.6-19.5 17.5-22 22.1-26 22-28 28.1-32 30-35 35.1-40 38-45 41.5-50 48-53 53.1-56 56.1-60 56-62 62.1-66 8-15.1 8-15.1 13-19.5 13-19.5 17.5-26 17.5-26 22-32 22-32 30-40 30-40 38-53 38-53 38-53 49-53 49-53 Product Code WEID.E1WF- 16 WEID.E1WF- 20a WEID.E1WF- 20b WEID.E1WF- 25a WEID.E1WF- 25b WEID.E1WF- 32a WEID.E1WF- 32b WEID.E1WF- 40a WEID.E1WF- 40b WEID.E1WF- 50a WEID.E1WF- 50b WEID.E1WF- 63a WEID.E1WF- 63b WEID.E1WF- 63c WEID.E1WF- 75a WEID.E1WF- 75b 1 Available in Stainless Steel add /SS to product code eg. WEID.E1WF-16/SS 2 Available with earth tag and shroud tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 234 Installation Accessories Type WDU and WPE - EEx e and EEx i Wiring Terminals EEx e II and EEx i IIC Zones 1,2,21,22 T6 Group II Cat 2 Terms of Sale and Delivery ATEX All deliveries are subject to our “General Terms of Sale and Delivery”. All data is subject to alteration and drawing are subject to modification. Illustrations may not be to scale. All prices can be found in a seperate list. This catalogue is valid from April 2006 and replaces any previous information. The seperate price list supersedes any previously issued prices or pricelists. Walsall Ltd fits Weidmuller component approved EEx terminals types WDU beige, WDU blue and WPE earth terminals as standard. Unless otherwise specified these terminals will always be used in all Walsall products. Lists of the most popular sizes encountered are given below. These are not exhaustive but reflect the vast majority used by Walsall and those generally carried in stock. If terminals outside these ranges are required they are readily available. ORDERING INFORMATION Size 2.5mmsq. 4.0mmsq. 6.0mmsq. 10mmsq. 16mmsq. 35mmsq. 70/95mmsq. 120/150mmsq. 235 EEx e Beige WDU 2.5 WDU 4 WDU 6 WDU 10 WDU 16 WDU 35 WDU 70/95 WDU 120/150 EEx i Blue WDU 2.5 blue WDU 4 blue WDU 6 blue WDU 10 blue WDU 16 blue WDU 35 blue WDU 70/95 blue WDU 120/150 blue EEx e,i Earth WPE 2.5 WPE 4 WPE 6 WPE 10 WPE 16 WPE 35 WPE 70/95 WPE 120/150 tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 236 Notes 237 Notes tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com tel: +44 (0)121 500 6161 fax: +44 (0)121 500 6300 [email protected] www.walsall-ltd.com 238