MPSH-30D Enclosure MPXS-30D-L MPXS-30D
Transcription
MPSH-30D Enclosure MPXS-30D-L MPXS-30D
28 Red w/ Stripe Black w/ Stripe White (from Master) MPXS-30D-L Green Black Red AC OUTPUT (to Master) AC INPUT Master (MA) FROM INVERTER: AC OUTPUT AC OUTPUT AC OUTPUT AC INPUT AC INPUT AC INPUT Black w/ Stripe Red w/ Stripe White Master Inverter AC INPUT Breaker (from Slave 1) AC OUTPUT MS-PAE Series Inverters WIRE RED w/STRIPE BLACK w/STRIPE WHITE RED BLACK GREEN White Black Red Black Red Green Black Red Black Red Slave 1 Inverter AC INPUT Breaker Red w/ Stripe MA SL1 SL2 MPSH-30D Enclosure Black w/ Stripe MPXS-30D-R (from Slave 2) AC OUTPUT (to Slave 2) AC INPUT Slave 2 (SL2) Black Red Green Slave 2 Inverter AC INPUT Breaker (to Slave 1) AC INPUT Slave 1 (SL1) TO MPSH-30D: INV HOT 2 OUT busbar INV HOT 1 OUT busbar AC NEUTRAL busbar AC INPUT breaker AC INPUT breaker GROUND busbar 3.0 Installation Figure 3-19a, MPXS-30D / MPSH-30D Inverter AC Wiring © 2011 Magnum Energy, Inc. 3.0 Installation Master Inverter AC INPUT Breaker Slave 1 AC INPUT Breaker Slave 2 AC INPUT Breaker MPSH-30D Enclosure MA .Black .Red ON OFF OFF OFF OFF OFF ON ON ON OFF ON ON ON ON OFF ON OFF ON OFF ON OFF OFF ON OFF ON OFF ON OFF OFF ON OFF OFF OFF OFF ON ON OFF ON ON ON OFF OFF ON LEG 1 OUT ON OFF AC Sub-Panel (Inverter Loads) ON LEG 2 OUT GND .Black .Red .Green .White NEU OUT OFF 240V .Black GND AC Main Panel (AC Source) 120V .Red .Black .Red NEU IN SL2 .Green .Red LEG 2 IN .White .Black LEG 1 IN SL1 120V Figure 3-19b, MPXS-30D / MPSH-30D External AC Wiring © 2011 Magnum Energy, Inc. 29 30 A B C D E F .Red cable to positive DC terminal .Red cable to positive DC terminal MA SL1 SL2 Red From MA inverter’s BTS port to BTS MPSH-30D Enclosure .Black cable to negative DC terminal Red MPXS30D-R Slave 2 (SL2) A – From MA inverter’s AC HOT 2 OUT to INV HOT 2 OUT busbar B – From MA inverter’s AC HOT 1 OUT to INV HOT 1 OUT busbar C – From MA inverter’s AC NEUTRAL to AC NEUTRAL busbar D – From MA inverter’s AC GROUND to GROUND busbar E – From MA inverter’s AC HOT 1 IN to MA AC INPUT breaker F – From MA inverter’s AC HOT 2 IN to MA AC INPUT breaker DC Equipment Ground Terminal MS-PAE Series Inverters Slave 1 (SL1) Red Black From MA inverter’s DC equipment ground terminal to DC GROUND busbar MPXS30D-L .Black cable to negative DC terminal Master (MA) 3.0 Installation Figure 3-19c, MPXS-30D / MPSH-30D Inverter DC Wiring © 2011 Magnum Energy, Inc. 3.0 Installation MPSH-30D Enclosure MA SL1 SL2 Red Black Red Black Red Connected to each inverter’s DC Equipment Ground Terminal (see also Figure 3-19c) BTS extension cable (300V) Connected to DC System Ground Positive (x3), negative (x3), and ground (x1) cables connected to inverter battery bank Battery Temperature Sensor Figure 3-19d, MPXS-30D / MPSH-30D Battery Bank DC Wiring © 2011 Magnum Energy, Inc. 31 3.0 Installation To Router’s: To Router’s: To Router’s: MA Stack Port SL1 Stack Port SL2 Stack Port P1 Comm Port P2 Comm Port P3 Comm Port Stack (SL2) Remote (P3) Stack (SL1) Remote (P2) To BTS Stack (MA) Remote (P1) MS-PAE Master (MA) MS-PAE Slave 1 (SL1) MS-PAE Slave 2 (SL2) Stacking Cable (300V) Remote Cable (300V) Stacking Ports SL1 SL2 Router Stacking Cables MA MPXS-30D-R MPXS-30D-L MPSH-30D Enclosure Extension Cable (300V) to BTS P1 P2 P3 Comm Ports BTS M A To MA inverter S L 1 S L 2 To Slave 2 inverter To Slave 1 inverter Remote Cables Figure 3-19e, MPXS-30D / MPSH-30D Communication Wiring 32 © 2011 Magnum Energy, Inc. 3.0 Installation 3.2.3 Wiring the MPXS-60S The following steps are basic guidelines for installing and connecting the AC, DC, and communication cables for the MPXS-60S. WARNING: To prevent electrical shock, make sure all AC power (inverter, generator, or utility) is off before making any AC connections inside the MP enclosure. MPXS-60S AC Wiring This section provides information on the AC wiring to/from the MS4024 inverters, and to/from the main panel and sub-panel. The MPXS-60S kit includes #6 AWG strand B wires for wiring to the AC terminals in the MP panel. The HOT 1 and HOT 2 wires into/out of the inverter are longer than needed. This allows you to cut and use the two excess wire lengths (one black and one red, or one black w/ stripe and one red w/ stripe) for routing AC wires from the bottom of the AC breakers to the MP’s busbar terminals. See Table 2-1 for AC wire size, color, length, and routing location. Inverter AC Input Wiring (see Figures 3-20a and 3-21a) LEG 2 AC Input Wiring 1. Route and attach a red wire from the top terminal of the MP enclosure’s AC input breaker (B1) to the HOT 2/LEG 2 inverter’s AC HOT 1 IN and AC HOT 2 IN terminals. 2. Route and attach a white wire from the MP enclosure’s AC NEUTRAL busbar to the HOT 2/LEG 2 inverter’s AC NEUTRAL terminal. 3. Route and attach a green wire from the MP enclosure’s GROUND busbar to the HOT 2/LEG 2 inverter’s AC GROUND terminal. LEG 1 AC Input Wiring NOTE: The LEG 1 AC input wiring is shown in the MP enclosure owner’s manual. Inverter AC Output Wiring (see Figures 3-20a and 3-21a) LEG 2 AC Output Wiring 1. Route and attach a red w/white stripe wire from the MP enclosure’s INV HOT 2 OUT busbar to HOT 2/LEG 2 inverter’s AC HOT 2 OUT and AC HOT 1 OUT terminals. 2. Route and attach a white wire w/black stripe from the MP enclosure’s AC NEUTRAL busbar to HOT 2/LEG 2 inverter’s AC NEUTRAL terminal. LEG 1 AC Output Wiring NOTE: The LEG 1 AC output wiring is shown in the MP enclosure owner’s manual. NOTE: For the full 60 amp AC pass-thru on MS4024 model inverters, the inverter’s HOT 1 and HOT 2 terminals must be wired together. Each terminal (separately) is only rated for 30 amp AC. See Figure 4-1 in the MP manual (PN: 64-0028), or refer to your MS Series owner’s manual for more info on AC wiring. © 2011 Magnum Energy, Inc. 33 3.0 Installation Left side view of inverter mounted on MPX Enclosure MS4024 Series Inverter (LEG 2) – showing AC wires from the internal AC wiring terminal See NOTE below .AC NEUT OUT 30 .AC HOT 2 OUT .AC HOT 1 OUT .AC HOT 2 IN .AC HOT 1 IN . . RED . WHITE GREEN Inverter AC Output Wires (Leg 2 Only) RED w/STRIPE . AC GROUND WHITE w/STRIPE . .AC NEUT IN Inverter AC Input Wires (Leg 2 Only) Figure 3-20a, Inverter AC Input and Output Wiring Diagram Info: When wiring the MS4024 (or any other MS Series inverter), both the inverter input and output neutral wires must be connected to a AC NEUTRAL busbar inside the MP enclosure. This is because — depending on the inverter’s operating mode — the inverter’s input and output neutral terminals may not be connected together (i.e., inverter’s neutrals are not connected when “inverting”, and are combined when “charging”). NOTE: Because a neutral to ground connection is also made in the MP enclosure, the neutral to ground connection inside the MS4024 must be disconnected. Refer to your MS4024 owner’s manual for information on how this is done. 34 © 2011 Magnum Energy, Inc. 3.0 Installation Bottom AC Breaker Wiring (see Figures 3-20b & 3-21b) • Info: Before proceeding any further, disconnect the black AC LEG 1 IN cable from the bottom left terminal of the AC breaker and reconnect to the bottom right terminal as shown in Figure 3-20b. Route and attach a red wire from the bottom terminal of the AC input breaker (B1) to the MP enclosure’s AC LEG 2 IN busbar. IMPORTANT: Prior to installing the MPXS-60S’s external AC wiring, disconnect and then recon- nect the AC LEG 1 IN black wire from the left breaker (B1) to the newly installed right breaker (B2), as shown in Figure 3-20b. This ensures that the phase relationship (LEG 1/black on right to LEG 2/ red on left) between the AC input source and the output are correct. MPSL-60S Enclosure B1 B2 NOTE: The AC LEG 1 IN wire is moved from the B1 position to the B2 position to ensure correct input/output phase relationship. Figure 3-20b, MPXS-60S / MPSL-60S AC Breaker Input Wire Transition External AC Main Panel Wiring (see Figure 3-21b) 1. Route and attach a black wire from the MP enclosure’s AC LEG 1 IN busbar to the main AC electrical panel. 2. Route and attach a red wire from the MP enclosure’s AC LEG 2 IN busbar to the main AC electrical panel. 3. Route and attach a green wire from the MP enclosure’s GROUND busbar to the main AC electrical panel’s Ground busbar. 4. Route and attach a white wire from the MP enclosure’s AC NEUTRAL busbar to the main AC electrical panel’s Neutral busbar. External AC Sub-Panel Wiring (see Figure 3-21b) 1. Route and attach a black wire from the MP enclosure’s AC LEG 1 OUT busbar to the AC electrical sub-panel. 2. Route and attach a red wire from the MP enclosure’s AC LEG 2 OUT busbar to the AC electrical sub-panel. 3. Route and attach a green wire from the MP enclosure’s GROUND busbar to the AC electrical sub-panel’s Ground busbar. 4. Route and attach a white wire from the MP enclosure’s AC NEUTRAL busbar to the AC electrical sub-panel’s Neutral busbar. AC Wiring Inspection After verifying all AC connections are correct, and all AC terminal screws are torqued correctly, replace the covers on the main electrical panel/sub-panel. © 2011 Magnum Energy, Inc. 35 3.0 Installation MPXS-60S DC Wiring This section covers the DC wiring to/from the inverters, and from the battery bank. WARNING: During normal operation, the terminals, busbars, and electrical components inside the MP enclosure may be energized – DO NOT TOUCH. WARNING: Disconnect all power sources before removing the cover. Even though DC voltage is “low voltage”, significant hazards may be present, particularly from short circuits of the battery system. CAUTION: DO NOT connect the battery cables to the battery bank until all wiring to the inverters and inside the MP/MPX enclosure is complete and the correct DC voltage and polarity have been verified. Installing the DC Cables From the Inverters to the MP (see Figure 3-21c) IMPORTANT: Coordinate the DC wiring to each inverter from each DC breaker such that the far left inverter is connected to the far left breaker (HOT 2/LEG 2 DC breaker), and the second inverter is connected to the second DC breaker (HOT 1/LEG 1 breaker), and so on. 1. Route a DC positive cable (red) from each inverter into the MP enclosure. 2. Connect the end of the DC positive cable (red) to the inverter’s positive DC terminal. 3. Connect the other end of the DC positive cable (red) to a DC circuit breaker’s top terminal. 4. Route a DC negative cable (black) from each inverter into the MP enclosure. 5. Connect the end of the DC negative cable (black) to the inverter’s negative DC terminal. 6. Connect the other end of the DC negative cable (black) to the top of the DC shunt’s busbar. 7. Route an appropriately sized DC equipment ground wire from each new inverter’s DC GROUND terminal to the DC GROUND busbar in the MP enclosure. 8. Verify all DC connections are torqued from 10 to 12 ft lbf (13.6 to 16.3 N-m). 9. Once the DC connections are correctly wired and tested, coat the terminals with an approved anti-oxidizing coating. Installing the DC Cables From the Battery Bank to the MP Enclosure (see Figure 3-21d) IMPORTANT: Damage may occur if DC power is connected to the MP enclosure before the Communication wiring is completed. DO NOT connect the DC cables from the MP enclosure to the battery bank until: 1) all DC, AC, and Comm wirings are completed, 2) the correct DC and AC overcurrent protection have been installed and, 3) the correct DC voltage and polarity have been verified. WARNING: Ensure all AC and DC breakers are switched OFF before connecting or disconnecting the battery cables, and that all AC and DC power is disconnected from the inverter. WARNING: Lethal currents will be present if the positive and negative cables attached to the battery bank touch each other. During the installation and wiring process, ensure the cable ends are insulated or covered to prevent touching/shorting the cables. CAUTION: The Magnum inverter is NOT reverse polarity protected, if this happens the inverter will be damaged and will not be covered under warranty. Before making the final DC connection from the MP enclosure down to the battery bank, verify the correct battery voltage and polarity by using a voltmeter. If the positive (+) terminal of the battery is connected to the negative (–) busbar of the MP enclosure and vice versa, severe damage will result. Ensure the cables are color-coded to avoid polarity confusion. 1. Route a DC positive battery cable (red) from the battery bank through the bottom of the MP enclosure for each inverter. 2. Connect the end of the DC positive battery cable (red) to the DC circuit breaker’s bottom battery positive connection. 36 © 2011 Magnum Energy, Inc. 3.0 Installation 3. Route a DC negative battery cable (black) from the battery bank thru the bottom of the MP enclosure for each inverter. 4. Connect the end of each DC negative battery cable (black) to the battery negative connection (DC shunt’s bottom busbar). 5. Route an appropriately sized DC equipment ground wire from the ground terminal in the battery bank enclosure to the DC ground terminal in the MP enclosure. 6. Route an appropriately sized DC grounding wire (green or bare wire) from the DC GROUND busbar in the MP enclosure to the system ground (see the MP owner’s manual for information on sizing and connecting the system ground wire). 7. Ensure the DC wire connections (to the inverter, DC circuit breaker, and DC shunt) are flush on the surface of the DC terminals and the hardware used to hold these connections are stacked correctly (see Figure 3-17); and then securely tighten these connections. IMPORTANT: Only after the entire installation is complete and all connections are verified, should the DC circuit breaker be closed to provide power to the inverters. MPXS-60S Communication Wiring Each MPXS-60S kit includes a remote cable and a stacking cable. The MP enclosure comes with an extension cable for connecting the inverter to a Battery Temperature Sensor (BTS). Connecting Remote Cables to Remotes (see Figure 3-21e) 1. Using the supplied RJ11 remote cables, route a cable from each inverter to each remote control (or router). 2. Connect one end of each remote cable to the Remote port (blue label) on each installed inverter. 3. Connect the other end of each remote cable to a separate remote control. Connecting Inverters Using Series Stacking Cable (see Figure 3-21e) 1. Using the supplied stacking cable, route the cable from the HOT 2/LEG 2 inverter’s Stack port (red label) through the MPX and MP enclosure to the HOT 1/LEG 1 inverter’s Stack port. 2. Connect the two ends of the series stacking cable to the Stack port of the two installed inverters. Battery Temperature Sensors (see Figures 3-21e) The Battery Temperature Sensor provides the inverter with precise battery temperature information that enables the batteries to be correctly charged under extreme temperature changes. If the BTS is not installed and batteries are subjected to large temperature changes, battery life may be shortened. 1. Using the supplied extension cables, route a cable from the each inverter through the MP enclosure to a BTS. Info: When the inverters are installed in a series, each inverter should have a BTS connected to its Battery Temp Sensor port. 2. Connect one end of each extension cable to the Battery Temp Sensor port (yellow label) on each inverter. 3. Connect the other end of each extension cable to the RJ-11 connector on a separate BTS. Connecting the DC Cables from the MP Enclosure to the Battery Bank Once all the wiring (AC, DC, and Comm) is completed, connect the DC cables from the MP enclosure to the battery bank. © 2011 Magnum Energy, Inc. 37 38 Red w/Stripe Green White Red Black Red B1 B2 Black w/Stripe HOT 2/LEG 2 Inverter AC INPUT Breaker TO MPSL-60S: INV HOT 2 OUT busbar INV HOT 1 OUT busbar AC NEUTRAL busbar AC HOT 2 INPUT breaker AC HOT 1 INPUT breaker GROUND busbar AC NEUTRAL busbar White w/Stripe FROM INVERTER: AC OUTPUT (INV HOT 2) AC OUTPUT (INV HOT 1) AC OUTPUT (NEUT OUT) AC INPUT (INV HOT 2) AC INPUT (INV HOT 1) AC INPUT (GROUND) AC INPUT (NEUT IN) MPXS-60S (from HOT 1/LEG 1 Inv.) AC OUTPUT MS4024 Series Inverters HOT 1/LEG 1 Inverter AC INPUT Breaker MPSL-60S Enclosure AC INPUT (to HOT 1/ LEG 1 Inv.) HOT 1/LEG 1 Inverter White Green Black WIRE RED w/STRIPE BLACK w/STRIPE WHITE w/STRIPE RED BLACK GREEN WHITE AC OUTPUT (from HOT 2/ LEG 2 Inv.) (to HOT 2/LEG 2 Inv.) AC INPUT HOT 2/LEG 2 Inverter 3.0 Installation White w/Stripe Figure 3-21a, MPXS-60S / MPSL-60S Inverter AC Wiring © 2011 Magnum Energy, Inc. 3.0 Installation MPSL-60S Enclosure B1 B2 LEG 2 LEG 1 .Red .Black AC Sub-Panel (Inverter Loads) ON ON ON ON OFF ON OFF OFF OFF ON ON OFF ON OFF ON ON OFF AC Main Panel (AC Source) OFF 120V OFF OFF ON OFF OFF OFF OFF OFF ON OFF ON OFF ON LEG 1 OUT OFF ON OFF ON ON OFF ON ON ON ON OFF OFF 240V LEG 2 OUT ON OFF OFF 120V NEU OUT ON NEU IN GND .Black LEG 2 IN .Red .White .Green .Green .White .Red .Black GND LEG 1 IN Figure 3-21b, MPXS-60S / MPSL-60S External AC Wiring © 2011 Magnum Energy, Inc. 39 40 .Red cable to positive DC terminal LEG 2 LEG 1 k Blac A – From HOT 2/LEG 2 inverter’s AC INPUT GROUND to GROUND busbar B – From HOT 2/LEG 2 inverter’s AC NEUTRAL IN to AC NEUTRAL busbar C – From HOT 2/LEG 2 inverter’s AC HOT 2 IN to HOT 2/LEG 2 AC INPUT breaker D – From HOT 2/LEG 2 inverter’s AC NEUTRAL OUT to AC NEUTRAL busbar E – From HOT 2/LEG 2 inverter’s AC HOT 1 IN to INV HOT 2 OUT busbar MPSL-60S Enclosure .Black cable to negative DC terminal BTS HOT 1/LEG 1 Inverter Red Black Red A B C D E From HOT 2/LEG 2 inverter’s DC equipment ground terminal to DC GROUND busbar From HOT 2/LEG 2 inverter’s BTS port to BTS MPXS-60S .Black cable to negative DC terminal DC Equipment Ground Terminal MS4024 Series Inverters .Red cable to positive DC terminal HOT 2/LEG 2 Inverter 3.0 Installation Figure 3-21c, MPXS-60S / MPSL-60S Inverter DC Wiring © 2011 Magnum Energy, Inc. 3.0 Installation MPSL-60S Enclosure HOT 1/ LEG 1 inverter HOT 2/ LEG 2 inverter d Re Red k ac Bl Black Connected to each inverter’s DC Equipment Ground Terminal (see also Figure 3-21c) BTS extension cables (300V) connected to each inverter’s BTS port (see also Figure 3-21e) Connected to DC System Ground Battery Temperature Sensors Positive (x2), negative (x2), and ground (x1) cables connected to inverter battery bank Figure 3-21d, MPXS-60S / MPSL-60S Battery Bank DC Wiring © 2011 Magnum Energy, Inc. 41 3.0 Installation To HOT 2/LEG 2 inverter’s Stack Port To HOT 1/LEG 1 inverter’s Stack Port To Remote 1 To Remote 2 To BTS 1 (via 300V extension cable) To BTS 1 (via 300V extension cable) MS4024 MS4024 HOT 2/LEG 2 Inverter HOT 1/LEG 1 Inverter Stacking Cable (300V) MPXS-60S Remote Cables (300V) MPSL-60S Enclosure .Remote 1 .Remote 2 NOTE: A router may be used instead of two remotes if the settings on both inverters are identical. Extension Cables (300V) to BTS’s BTS 1 BTS 2 Figure 3-21e, MPXS-60S / MPSL-60S Communication Wiring 42 © 2011 Magnum Energy, Inc. 3.0 Installation 3.2.4 Wiring the MPXD-30D The following steps are basic guidelines for installing and connecting the AC, DC, and communication wiring for the MPXD-30D. WARNING: To prevent electrical shock, make sure all AC power (inverter, generator, or utility) is off before making any AC connections inside the MP enclosure. MPXD-30D AC Wiring This section provides information on the AC wiring to/from the MS-PAE Series inverters, and to/ from the main and sub-panels. Inverter AC Input Wiring (see Figures 3-22a.1 and 3-22a.2) 1. Route and attach a black wire from the top right terminal of the new AC input breakers (left MP enclosure) to each inverter’s AC HOT 1 IN terminal. 2. Route and attach a red wire from the top left terminal of the new AC input breakers to each inverter’s AC HOT 2 IN terminal. 3. Route and attach a green wire from the left MP enclosure’s GROUND busbar to each inverter’s AC GROUND terminal. Inverter AC Output Wiring (see Figures 3-22a.1 and 3-22a.2) 1. Route and attach a black w/white stripe wire to each inverter’s AC HOT 1 OUT terminal from the left MP enclosure’s INV HOT 1 OUT busbar. 2. Route and attach a red w/white stripe wire to each inverter’s AC HOT 2 OUT terminal from the left MP enclosure’s INV HOT 2 OUT busbar. 3. Route and attach a white wire from the left MP enclosure’s AC NEUTRAL busbar to each inverter’s AC NEUTRAL terminal. Bottom AC Breaker Wiring (see Figure 3-22b) 1. Route and attach a black wire to the left MP enclosure’s AC LEG 1 IN busbar from the bottom right terminal of each of the new AC input breakers. 2. Route and attach a red wire to the left MP enclosure’s AC LEG 2 IN busbar from the bottom of each of the new AC input breakers. External AC Main Panel Wiring (see Figure 3-22b) 1. Route and attach a black wire to the left MP enclosure’s AC LEG 1 IN busbar from the main electrical panel. 2. Route and attach a red wire to the left MP enclosure’s AC LEG 2 IN busbar from the main electrical panel. 3. Route and attach a green wire to the left MP enclosure’s GROUND busbar from the main electrical panel’s Ground busbar. 4. Route and attach a white wire to the left MP enclosure’s AC NEUTRAL busbar from the main electrical panel’s Neutral busbar. AC AC AC AC External AC Sub-Panel Wiring (see Figure 3-22b) 1. Route and attach a black wire from the left MP enclosure’s AC LEG 1 OUT busbar to the AC electrical sub-panel. 2. Route and attach a red wire from the left MP enclosure’s AC LEG 2 OUT busbar to the AC electrical sub-panel. 3. Route and attach a green wire from the left MP enclosure’s GROUND busbar to the AC electrical sub-panel’s Ground busbar. 4. Route and attach a white wire from the left MP enclosure’s AC NEUTRAL busbar to the AC electrical sub-panel’s Neutral busbar. AC Wiring Inspection After verifying all AC connections are correct and all AC terminal screws are torqued correctly, replace the covers on the main electrical panel/sub-panel. © 2011 Magnum Energy, Inc. 43 3.0 Installation MPXD-30D DC Wiring This section covers the DC wiring to/from the inverters, and from the battery bank. WARNING: During normal operation, the terminals, busbars, and electrical components inside the MP enclosure may be energized – DO NOT TOUCH. WARNING: Disconnect all power sources before removing the cover. Even though DC voltage is “low voltage”, significant hazards may be present, particularly from short circuits of the battery system. CAUTION: DO NOT connect the battery cables to the battery bank until all wiring to the inverters and inside the MP/MPX enclosure is complete and the correct DC voltage and polarity have been verified. Installing the DC Cables From the Inverters to the MP (see Figure 3-22c) IMPORTANT: Coordinate the DC wiring to each inverter from each DC breaker such that the far left inverter (Master)is connected to the far left breaker (Master DC breaker), and the second inverter (Slave) is connected to the second DC breaker (Slave 1 DC breaker), and so on. 1. Route a DC positive cable (red) from each inverter into the MP enclosure. 2. Connect the end of the DC positive cable (red) to the inverter’s positive DC terminal. 3. Connect the other end of the DC positive cable (red) to a DC circuit breaker’s top terminal. 4. Route a DC negative cable (black) from each inverter into the MP enclosure. 5. Connect the end of the DC negative cable (black) to the inverter’s negative DC terminal. 6. Connect the other end of the DC negative cable (black) to the top of the DC shunt’s busbar. 7. Route an appropriately sized DC equipment ground wire from each new inverter’s DC GROUND terminal to the DC GROUND busbar in the MP enclosure. 8. Verify all DC connections are torqued from 10 to 12 ft lbf (13.6 to 16.3 N-m). 9. Once the DC connections are correctly wired and tested, coat the terminals with an approved anti-oxidizing coating. Installing the DC Cables From the Battery Bank to the MP Enclosure (see Figure 3-22d) IMPORTANT: Damage may occur if DC power is connected to the MP enclosure before the Communication wiring is completed. DO NOT connect the DC cables from the MP enclosure to the battery bank until: 1) all DC, AC, and Comm wirings are completed, 2) the correct DC and AC overcurrent protection have been installed and, 3) the correct DC voltage and polarity have been verified. WARNING: Ensure all AC and DC breakers are switched OFF before connecting or disconnecting the battery cables, and that all AC and DC power is disconnected from the inverter. WARNING: Lethal currents will be present if the positive and negative cables attached to the battery bank touch each other. During the installation and wiring process, ensure the cable ends are insulated or covered to prevent touching/shorting the cables. CAUTION: The Magnum inverter is NOT reverse polarity protected, if this happens the inverter will be damaged and will not be covered under warranty. Before making the final DC connection from the MP enclosure down to the battery bank, verify the correct battery voltage and polarity by using a voltmeter. If the positive (+) terminal of the battery is connected to the negative (–) busbar of the MP enclosure and vice versa, severe damage will result. Ensure the cables are color-coded to avoid polarity confusion. 1. Route a DC positive battery cable (red) from the battery bank through the bottom of the MP enclosure for each inverter. 2. Connect the end of the DC positive battery cable (red) to the DC circuit breaker’s bottom battery positive connection. 44 © 2011 Magnum Energy, Inc. 3.0 Installation 3. Route a DC negative battery cable (black) from the battery bank thru the bottom of the MP enclosure for each inverter. 4. Connect the end of each DC negative battery cable (black) to the battery negative connection (DC shunt’s bottom busbar). 5. Route an appropriately sized DC equipment ground wire from the ground terminal in the battery bank enclosure to the DC ground terminal in the MP enclosure. 6. Route an appropriately sized DC grounding wire (green or bare wire) from the DC GROUND busbar in the MP enclosure to the system ground (see the MP owner’s manual for information on sizing and connecting the system ground wire). 7. Ensure the DC wire connections (to the inverter, DC circuit breaker, and DC shunt) are flush on the surface of the DC terminals and the hardware used to hold these connections are stacked correctly (see Figure 3-17); and then securely tighten these connections. IMPORTANT: Only after the entire installation is complete and all connections are verified, should the DC circuit breaker be closed to provide power to the inverters. MPXD-30D Communication Wiring Each MPXD-30D kit includes a remote cable and a stacking cable for connecting to a router. The Magnum router comes with two CAT 5 cables and two RJ11 communication cables. The MP enclosure comes with an extension cable for connecting the inverter to a Battery Temperature Sensor (BTS). Connecting Remote Cables to the Router (see Figure 3-22e) 1. Using the supplied RJ11 remote cables, route a cable from each inverter to the attached router. 2. Connect one end of each remote cable to the Remote port (blue label) on each installed inverter. 3. Connect the other end of each remote cable to its respective port (P1-P6) on the router. Info: It is recommended that the Master inverter be connected to Port 1, Slave 1 to Port 2 etc., in order to keep track of which inverter is displayed on each port. Connecting Stacking Cables to the Router (see Figure 3-22e) 1. Using the supplied stacking (CAT 5) cables, route a cable from each inverter to the attached router. 2. Connect one end of each stacking cable to the Stack Port (red label) on each installed inverter. 3. Connect the other end of each stacking cable to its respective CAT 5 port on the router (MA, SL1, SL2, and SL3 ports for the appropriate number of installed inverters). Info: At least one CAT 5 cable must be plugged into the router’s MA port in order for the router to operate any inverters. Battery Temperature Sensors (BTS) (see Figures 22e) The Battery Temperature Sensor provides the inverter with precise battery temperature information that enables the batteries to be correctly charged under extreme temperature changes. If the BTS is not installed and batteries are subjected to large temperature changes, battery life may be shortened. 1. Using the supplied extension cable, route it from the Master inverter through the MPX and MP enclosure to the battery bank. 2. Connect one end of the extension cable to the Battery Temp Sensor port (yellow label) on the Master inverter. 3. Connect the other end of the extension cable to the RJ-11 connector on a BTS (connected to the battery bank). Connecting the DC Cables from the MP Enclosure to the Battery Bank Once all the wiring is completed, connect the DC cables from the MP enclosure to the battery bank. © 2011 Magnum Energy, Inc. 45 46 Green Black Red White Black w/ Stripe Red w/ Stripe Green Black Red MPDH-30D Enclosure AC Side/DC Side AC OUTPUT (from Slave 2) Black Red Green Red w/ Stripe Black w/ Stripe White White Black w/ Stripe Red w/ Stripe See Figure 3-22a.2 for a closeup MA SL1 SL2 SL3 AC INPUT (to Slave 1) MS-PAE Series Inverters AC INPUT (to Slave 2) Slave 2 (SL2) TO MPDH-30D: INV HOT 2 OUT busbar INV HOT 1 OUT busbar AC NEUTRAL busbar AC INPUT breaker AC INPUT breaker GROUND busbar MPXD30D-R AC OUTPUT (from Slave 3) Slave 3 (SL3) AC INPUT (to Slave 3) MPXD30D-L AC OUTPUT (from Slave 1) Slave 1 (SL1) FROM INVERTER: AC OUTPUT AC OUTPUT AC OUTPUT AC INPUT AC INPUT AC INPUT Black Red Green Red w/ Stripe Black w/ Stripe White AC OUTPUT (from Master) AC INPUT (to Master) MASTER (MA) WIRE RED w/STRIPE BLACK w/STRIPE WHITE RED BLACK GREEN 3.0 Installation Figure 3-22a.1, MPXD-30D / MPDH-30D Inverter AC Wiring © 2011 Magnum Energy, Inc. Green White Black w/stripe Red w/stripe Black Red Green Black Red MA SL1 SL2 SL3 1 – White 2 – White 3 – Black w/stripe 4 – Black w/stripe 5 – Red w/stripe 6 – Red w/stripe 1 2 3 4 5 6 © 2011 Magnum Energy, Inc. 7 – Green 8 – Green 9 – Red 10 – Black 11 – Red 12 – Black 7 8 9 10 11 12 3.0 Installation White Black w/stripe Red w/stripe Figure 3-22a.2, MPXD-30D / MPDH-30D Inverter AC Wiring (Closeup) 47 3.0 Installation MPDH-30D Enclosure (AC side) MA SL1 SL2 SL3 .Black .Red .Black .Red .Black .Red .Black .Red Black Red OFF OFF OFF ON OFF ON OFF ON OFF OFF ON OFF OFF ON OFF OFF OFF ON OFF ON OFF ON OFF ON ON OFF AC Sub-Panel (Inverter Loads) ON OFF ON ON OFF OFF ON ON ON OFF ON ON ON ON AC Main Panel (AC Source) LEG 1 OUT ON ON OFF OFF 240V LEG 2 OUT NEU OUT ON OFF OFF 120V GND .Black NEU IN .Red LEG 1 IN .White .Green .Green .White .Black .Red GND LEG 2 IN 120V Figure 3-22b, MPXD-30D / MPDH-30D External AC Wiring 48 © 2011 Magnum Energy, Inc. © 2011 Magnum Energy, Inc. MPDH-30D (AC side) Red cable to positive DC terminal DC Equipment Ground Terminal MS-PAE Series Inverters Red Red Red Red MA SL1 SL2 SL3 Black Red cable to positive DC terminal MPDH-30D (DC side) Black cable to negative DC terminal Slave 2 (SL2) Black BTS ext. connects to Master’s BTS port Black cable to Master negative DC terminal Redcable to Master positive DC terminal Black cable to negative DC terminal Slave 1 (SL1) Black cable to Slave 3 negative DC terminal Red cable to Slave 3 positive DC terminal 3.0 Installation Black Black Figure 3-22c, MPXD-30D / MPDH-30D Inverter DC Wiring 49 3.0 Installation Connected to each inverter’s DC Equipment Ground Terminal (see also Figure 3-22c) MA SL1 MPDH-30D Enclosure SL3 SL2 SL3 Black Black SL1 Black BTS extension (330V) cable MA Black Red Red Red Red Positive (x4), negative (x4), and ground (x1) cables connected to inverter battery bank SL2 Connected to DC System Ground Battery Temperature Sensor Figure 3-22d, MPXD-30D / MPDH-3D Battery Bank DC Wiring 50 © 2011 Magnum Energy, Inc. © 2011 Magnum Energy, Inc. Stacking Cables To Slave 2 inverter P1 P2 P3 P4 Remote Cables .To Master To Slave 1 inverter inverter SL3 SL2 SL1 MA Stacking Ports Router Remote Cable (300V) MPXD-30D-L .To BTS (300V) To Slave 3 inverter Comm Ports MPDH-30D Extension Cable (300V) to BTS Slave 2 (SL2) .MS-PAE .MS-PAE .MS-PAE Slave 1 (SL1) .P4 Comm Port .P3 Comm Port .P2 Comm Port MASTER (MA) .SL3 Stack Port .SL2 Stack Port .SL1 Stack Port .MA Stack Port .P1 Comm Port BTS MPXD-30D-R Slave 3 (SL3) .MS-PAE .To Router’s: .To Router’s: .To Router’s: .To Router’s: 3.0 Installation Figure 3-22e, MPXD-30D / MPDH-30D Communication Wiring 51 3.0 Installation 3.3 Installation Checklist After all electrical connections from the MP enclosure to the inverters, batteries, AC source, and subpanel have been completed, refer to the installation checklist in Section 3.13 of your MP Enclosure Owner’s Manual (PN: 64-0028) to confirm proper installation. 3.4 Functional Test Once you confirm that the system has been installed properly, you are ready to perform a functional test. Refer to the functional test procedure in Section 3.14 of your MP Enclosure Owner’s Manual. WARNING: During the functional test – because the front cover has been removed — you are exposed to potential dangerous voltages and shock hazards inside the MP enclosure that may cause damage, injury, or death. If you do not have experience working with AC and DC voltage circuits, do not attempt this test – use an experienced electrical installer. CAUTION: During the functional test, if any step cannot be verified or is incorrect, stop and recheck/correct the connections before proceeding to the next step. 3.5 Attaching Labels and Covers The MPX kit has labels for the DC breaker’s positive cable connections (see Figure 2-2). The “Top Connection of DC Breaker” label affixes to the top of the new DC breaker. The “Bottom Connection of DC Breaker” label affixes to the bottom of the new DC breaker. Refer to Figure 3-23 for proper placement of both labels. Figure 3-23, Attaching the Interior DC Labels 52 © 2011 Magnum Energy, Inc. 3.0 Installation Attaching Covers MP Enclosure - Use the supplied screws and washers to secure the MP enclosure’s cover (see Figure 3-24). NOTE: Use #10-32 Star washers (x8), and #10-32 x ⅜” T25 Torx Drive screws (x8) Figure 3-24, Attaching the MP Enclosure Cover © 2011 Magnum Energy, Inc. 53 3.0 Installation MPX - Use the front cover screws and washers that you removed earlier (Section 3.1.1) to reattach the MPX extension’s cover (see Figure 3-25). NOTE: Use the #10-32 Star washers (x4) and #10-32 x 3/8” T25 Torx Drive screws (x4) you removed in Section 3.1.1 Figure 3-25, Attaching the MPX Cover 54 © 2011 Magnum Energy, Inc. 3.0 Installation Router - Use the supplied screws and washers (x2) to secure the router’s cover (see Figure 3-26). NOTE: Use the supplied #8 x 3/4" Phillips drive flat head screws (x2) to secure the router cover Figure 3-26, Attaching the Router Cover © 2011 Magnum Energy, Inc. 55 3.0 Installation SLAVE 1 INVERTER MASTER INVERTER INVERTER DC DISCONNECT SWITCH ON TO INVERT SLAVE 1 INVERTER MASTER INVERTER INVERTER AC INPUT SWITCH ON TO CHARGE / PASS-THRU MASTER INVERTER SLAVE 1 INVERTER Figure 3-27, Attaching the Exterior Labels MPSL/MPSH 56 © 2011 Magnum Energy, Inc. A © 2011 Magnum Energy, Inc. AB CD EE AB CD FF B C D SLAVE 2 INVERTER SLAVE 3 INVERTER C- D- F- SWITCH ON TO INVERT INVERTER DC DISCONNECT SWITCH ON TO CHARGE / PASS-THRU INVERTER AC INPUT SLAVE 1 INVERTER B- E- MASTER INVERTER A- KEY 3.0 Installation Figure 3-28, Attaching the Exterior Labels MPDH 57 4.0 Warranty and Service Information 4.0 Warranty and Service Information 4.1 Limited Warranty Magnum Energy, Inc., warrants the MPX Extension Kit to be free from defects in material and workmanship that result in product failure during normal usage, according to the following terms and conditions: 1. The limited warranty for the product extends for 12 months beginning from the product’s original date of purchase. 2. The limited warranty extends to the original purchaser of the product and is not assignable or transferable to any subsequent purchaser. 3. During the limited warranty period, Magnum Energy will repair, or replace at Magnum Energy’s option, any defective parts, or any parts that will not properly operate for their intended use with factory new or remanufactured replacement items if such repair or replacement is needed because of product malfunction or failure during normal usage. The limited warranty does not cover defects in appearance, cosmetic, decorative or structural parts or any non-operative parts. Magnum Energy’s limit of liability under the limited warranty shall be the actual cash value of the product at the time the original purchaser returns the product for repair, determined by the price paid by the original purchaser. Magnum Energy shall not be liable for any other losses or damages. 4. Upon request from Magnum Energy, the original purchaser must prove the product’s original date of purchase by a dated bill of sale, itemized receipt. 5. The original purchaser shall return the product prepaid to Magnum Energy in Everett, WA. After the completion of service under this limited warranty, Magnum Energy will return the product prepaid to the original purchaser via a Magnum-selected non-expedited surface freight within the contiguous United States and Canada; this excludes Alaska and Hawaii. 6. This limited warranty is voided if: • the product has been modified without authorization • the serial number has been altered or removed • the product has been damaged from abuse, neglect, accident, high voltage or corrosion • the product was not installed and operated according to the owner's manual 4.2 How to Receive Repair Service If your product requires warranty service or repair, contact either: 1. An Authorized Service Center, which are listed on the Magnum Energy website at www.magnumenergy.com/servicecenters.htm; or 2. Magnum Energy, Inc. at: Telephone: 425-353-8833 Fax: 425-353-8390 Email: [email protected] If returning the product directly to Magnum Energy for repair, you must: • return the unit in the original, or equivalent, shipping container • ensure the product is properly packaged, any damage due to inadequate packaging is not covered under warranty • receive a Return Materials Authorization (RMA) number from the factory prior to the return of the product to Magnum Energy for repair • place RMA numbers clearly on the shipping container or on the packing slip BEFORE RETURNING ANY UNIT TO MAGNUM ENERGY INC., A RETURN MATERIAL AUTHORIZATION (RMA) NUMBER IS REQUIRED. 58 © 2011 Magnum Energy, Inc. Magnum Energy, Inc. 2211 West Casino Rd. Everett, WA 98204 Phone: 425-353-8833 Fax: 425-353-8390 Web: www.magnumenergy.com MPX Owner’s Manual (PN: 64-0051 Rev A)