Centrifugal roof mounted fans MAX

Transcription

Centrifugal roof mounted fans MAX
Centrifugal roof mounted fans
MAX-TEMP CTHB / CTHT Series - Horizontal discharge
F400-120
Range of centrifugal roof mounted fans
in horizontal discharge format, designed
for smoke extraction in fire conditions
and certified F400-120 (CE marked) (1).
All models are suitable for air stream
temperature up to 120ºC.
Bases are manufactured from galvanised
sheet steel and cowls are manufactured
from spun aluminium.
All models incorporate bird-proof guard.
Available, depending upon the model,
with single or three phase motors in 4, 6,
8, 4/8 or 6/12 poles.
(1) Except 140, 180 and 200 models.
Motors
All motors are IP55, Class F and equipped
with ball bearings greased for life.
Electrical supply:
Single phase 230V-50Hz.
Three phase 400V-50Hz.
(See characteristics chart).
Speed controllable by voltage, up to 400
model. Three phase motors are
controllable by frequency inverter.
When is using a speed controller, the
electrical installation must be equipped
with a security system which allows the
maximum speed of the fans in cas of fire.
Additional information
140, 180, 200 and 225 models are
specially recommended for extracting
smoke from the fireplaces.
Only F400-120 at maximum fan speed.
Specific applications
F400-120
Easy to install
Supports easing the
installation on the roof.
Self cooling system
Special design in order to
cool the motor and to extend
the life of the assembly.
Bird-proof guard.
Approved to
Continuous
EN12101-3
operation
standard
Certificate nº
0370-CPD-0347
Car Parks
Industrial
and
commercial
kitchens
Additional applications
for 140,180,200 and 225 models
Continuous
Smoke
extract
Backward curved centrifugal impellers
To prevent accumulation of dirt. Models up to 400 are
manufactured from galvanised steel sheet. Models from 450 to
630 are manufactured in sheet steel protected against corrosion
by cataforesis primer and black polyester paint finish.
www.solerpalau.com
Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT
371
Centrifugal roof mounted fans
MAX-TEMP CTVB / CTVT Series - Vertical discharge
F400-120
Range of centrifugal roof mounted fans
in vertical discharge format, designed
for smoke extraction in fire conditions
and certified F400-120 (CE marked) (1).
All models are suitable for air stream
temperature up to 120ºC.
Bases are manufactured from galvanised
sheet steel and cowls are manufactured
from spun aluminium.
All models incorporate bird-proof guard.
Available, depending upon the model, with
single or three phase motors in 4, 6, 8, 4/8
or 6/12 poles.
(1) Except 140, 180 and 200 models.
Motors
All motors are IP55, Class F and
equipped with ball bearings greased
for life.
Electrical supply:
Single phase 230V-50Hz.
Three phase 400V-50Hz.
(See characteristics chart).
Speed controllable by voltage, up to
400 model. Three phase motors are
controllable by frequency inverter.
When is using a speed controller, the
electrical installation must be equipped
with asecurity system which allows the
maximum speed of the fans in cas of fire.
Models configuration 140 to 400
Additional information
140, 180, 200 and 225 models are
specially recommended for extracting
smoke from the fireplaces.
Models configuration 450 to 710
Only F400-120 at maximum fan speed.
Specific applications
Cooling duct
Enables the motor cooling
when the fan is extracting
air at an extremely high
temperature.
Easy to install
Supports easing the
installation on the roof.
Self cooling system
Special design in order to
cool the motor and to extend
the life of the assembly.
F400-120
Approved to
Continuous
EN12101-3
operation
standard
Certificate nº
0370-CPD-0347
Car Parks
Industrial
and
commercial
kitchens
Additional applications
for 140,180,200 and 225 models
Continuous
Backward curved centrifugal impellers
To prevent accumulation of dirt. Models up to 400 are
manufactured from galvanised steel sheet. Models
from 450 to 630 are manufactured in sheet steel
protected against corrosion by cataforesis primer and
black polyester paint finish.
372
Smoke
extract
Bird-proof guard.
Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT
www.solerpalau.com
Centrifugal roof mounted fans
MAX-TEMP CTHB/CTHT - CTVB/CTVT Series
Technical characteristics for models with horizontal discharge CTHB/ CTHT
Before installation check that the product electrical characteristics listed on the data plate label (voltage, power, frequency, etc.) match those of the intended
electrical supply.
6 poles
single phase
4 poles
single phase
Model
Speed
(rpm)
4 poles
three phase
6 poles
three phase
Maximum
airflow
(m3/h)
Sound pressure
level* at 2/3 Qmax
(dB(A))
Speed
controllable
(**)
Switch for
2-speed motors
at 230 V
at 400 V
60
0,32
–
800
46
52
7,5
REB-1N
–
CTHB/4-180
1330
70
0,33
–
990
46
52
8
REB-1N
–
CTHB/4-200
CTHB/4-225
F400-120
Inlet
Weight
(kg)
1370
Outlet
1320
120
0,60
–
1450
49
55
14,2
REB-1N
–
1350
170
0,90
–
2100
53
59
17
REB-2,5N
–
CTHB/4-250
F400-120
1320
280
1,40
–
3100
57
62
28
REB-2,5N
–
CTHB/4-315
F400-120
1375
590
2,70
–
4900
60
66
32
REB-5
–
CTHB/4-400
F400-120
1380
1100
5,30
–
7000
67
73
42,5
REB-10
–
940
80
0,40
–
970
38
45
14,2
REB-1N
–
CTHB/6-200
CTHB/6-225
F400-120
890
90
0,40
–
1400
42
48
17
REB-1N
–
CTHB/6-250
F400-120
940
100
0,57
–
2000
45
52
28
REB-1N
–
CTHB/6-315
F400-120
840
170
0,81
–
3200
49
55
32
REB-1N
–
F400-120
950
350
1,60
–
4500
56
62
42,5
REB-2,5N
–
1375
60
–
0,17
800
46
52
7,5
RMT-1,5
–
CTHB/6-400
CTHT/4-180
1350
70
–
0,17
990
46
52
8
RMT-1,5
–
CTHT/4-200
1340
130
–
0,35
1450
49
55
14,2
RMT-1,5
–
CTHT/4-225
F400-120
1360
170
–
0,50
2100
53
59
17
RMT-1,5
–
CTHT/4-250
F400-120
1400
300
–
0,80
3100
57
62
28
RMT-1,5
–
CTHT/4-315
F400-120
1410
620
–
1,50
4900
60
66
32
RMT-2,5
–
CTHT/4-400
F400-120
1350
920
–
1,80
7000
67
73
42,5
RMT-2,5
–
CTHT/4-450
F400-120
1440
2300
–
4,60
10200
71
76
67
VFKB-48
–
950
80
–
0,24
970
38
45
14,2
RMT-1,5
–
CTHT/6-225
F400-120
900
90
–
0,23
1400
42
48
17
RMT-1,5
–
CTHT/6-250
F400-120
950
100
–
0,41
2000
45
52
28
RMT-1,5
–
CTHT/6-200
8 poles
three phase
Maximum absorbed
current
(A)
CTHB/4-140
CTHT/4-140
2 speeds
three phase
Maximum
absorbed
power
(W)
CTHT/6-315
F400-120
900
180
–
0,50
3200
49
55
32
RMT-1,5
–
CTHT/6-400
F400-120
925
350
–
1,00
4500
56
62
42,5
RMT-1,5
–
CTHT/6-450
F400-120
940
850
–
3,50
6900
59
66
67
VFKB-45
–
CTHT/6-500
F400-120
965
1400
–
4,30
10500
63
69
104
VFKB-45
–
CTHT/6-560
F400-120
950
2400
–
5,30
16000
66
73
118
VFKB-48
–
CTHT/6-630
F400-120
950
3700
–
8,30
21000
70
76
156
VFTM-TRI 4
–
CTHT/6-710
F400-120
980
6800
–
13,80
28900
77
83
217
VFTM-TRI 7,5
–
CTHT/8-450
F400-120
700
700
–
2,10
5000
55
61
67
VFKB-45
–
CTHT/8-500
F400-120
725
770
–
2,40
7500
55
62
104
VFKB-45
–
CTHT/8-560
F400-120
730
1100
–
3,60
11500
58
65
118
VFKB-45
–
CTHT/8-630
F400-120
735
1650
–
4,90
15000
62
69
156
VFKB-48
–
CTHT/8-710
F400-120
730
2900
–
7,20
21700
70
76
226
VFKB-48
–
CTHT/4/8-225
F400-120
1300/700
180/70
–
0,3/0,2
2100/1050
53/38
59/44
17
–
–
CTHT/4/8-315
F400-120
1400/700
370/230
–
1,1/0,9
4900/2400
60/45
66/51
33
–
DEMA 1/1,3 DH
CTHT/4/8-400
F400-120
1400/700
1000/260
–
1,8/1,0
7000/3500
67/52
73/58
44
–
DEMA 1/2,3 DH
CTHT/4/8-450
F400-120
1400/700
2400/600
–
6,1/2,5
10200/5100
71/55
76/61
69
–
DEMA 3,1/7,6 DH
CTHT/6/12-450
F400-120
960/490
500/190
–
2/1
6900/3400
59/44
66/51
72
–
DEMA 1/2,3 DH
CTHT/6/12-500
F400-120
980/490
1520/430
–
4,5/2,2
10500/5300
63/48
69/54
109
–
DEMA 2,3/5,7 DH
CTHT/6/12-560
F400-120
950/480
2400/640
–
5,6/2,2
16000/7000
66/51
73/58
124
–
DEMA 2,3/5,7 DH
CTHT/6/12-630
F400-120
960/480
4100/730
–
8,1/2,6
21000/10500
70/55
76/61
161
–
DEMA 3,1/10 DH
F400-120
950/450
6700/850
–
14,1/5,4
28900/15000
77/62
83/68
226
–
DEMA 5,7/15,5 DH
CTHT/6/12-710
* The ratings of sound levels are pressure values measured in dB(A) at 1,5 m at 2/3 Qmax.
** Three phase speed controllers (RMT) or inverter controller (VFKB/VFTM): Three phase 400V.
www.solerpalau.com
Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT
373
Centrifugal roof mounted fans
MAX-TEMP CTHB/CTHT - CTVB/CTVT Series
Technical characteristics for models with vertical discharge CTVB/ CTVT
Before installation check that the product electrical characteristics listed on the data plate label (voltage, power, frequency, etc.) match those of the intended
electrical supply.
4 poles
three phase
6 poles
single phase
4 poles
single phase
Model
6 poles
three phase
8 poles
three phase
Maximum
airflow
(m3/h)
Sound pressure level*
at 2/3 Qmax
(dB(A))
Weight
(kg)
Speed
controllable
(**)
Switch for
2-speed motors
Maximum
absorbed
power
(W)
at 230 V
at 400 V
CTVB/4-140
1375
60
0,3
–
725
46
49
10
REB-1N
–
CTVB/4-180
1330
60
0,3
–
830
46
49
10,5
REB-1N
–
CTVB/4-200
Inlet
Outlet
1330
100
0,60
–
1320
49
53
17
REB-1N
–
CTVB/4-225
F400-120
1350
130
0,71
–
1900
53
56
19,8
REB-1N
–
CTVB/4-250
F400-120
1325
325
1,6
–
2800
56
60
35
REB-2,5N
–
CTVB/4-315
F400-120
1390
570
2,70
–
4200
60
64
39
REB-5
–
CTVB/4-400
F400-120
1390
1100
5,30
–
6250
67
70
50
REB-10
–
940
80
0,40
–
900
38
42
17
REB-1N
–
CTVB/6-225
F400-120
890
90
0,40
–
1300
41
45
19,8
REB-1N
–
CTVB/6-250
F400-120
940
100
0,57
–
1850
45
49
35
REB-1N
–
CTVB/6-315
F400-120
870
160
0,80
–
2800
48
53
39
REB-1N
–
CTVB/6-400
F400-120
960
340
1,60
–
4300
55
59
50
REB-2,5N
–
CTVB/6-200
CTVT/4-140
1400
60
–
0,18
725
46
49
10
RMT-1,5
–
CTVT/4-180
1350
60
–
0,18
830
46
49
10,5
RMT-1,5
–
CTVT/4-200
1340
130
–
0,44
1200
49
53
17
RMT-1,5
–
CTVT/4-225
F400-120
1360
180
–
0,47
1900
53
56
19,8
RMT-1,5
–
CTVT/4-250
F400-120
1400
300
–
0,8
2800
56
60
35
RMT-1,5
–
CTVT/4-315
F400-120
1410
400
–
1,4
4200
60
64
39
RMT-2,5
–
CTVT/4-400
F400-120
1330
1000
–
1,80
6250
67
70
50
RMT-2,5
–
CTVT/4-450
F400-120
1440
2100
–
4,3
8850
70
74
75
VFKB-45
–
950
80
–
0,24
900
38
42
17
RMT-1,5
–
CTVT/6-200
2 speeds
three phase
Maximum
absorbed
current
(A)
Speed
(rpm)
CTVT/6-225
F400-120
900
90
–
0,23
1300
41
45
19,8
RMT-1,5
–
CTVT/6-250
F400-120
950
100
–
0,41
1850
45
49
35
RMT-1,5
–
CTVT/6-315
F400-120
910
160
–
0,44
2800
48
53
39
RMT-1,5
–
CTVT/6-400
F400-120
930
350
–
1,00
4300
55
59
50
RMT-1,5
–
CTVT/6-450
F400-120
950
800
–
3,5
5900
59
63
75
VFKB-45
–
CTVT/6-500
F400-120
975
1500
–
3,7
9500
62
66
115
VFKB-45
–
CTVT/6-560
F400-120
950
2400
–
5,50
13000
66
70
129
VFKB-48
–
CTVT/6-630
F400-120
950
3900
–
8,3
19500
70
74
168
VFTM-TRI 4
–
CTVT/6-710
F400-120
980
7250
–
13,6
25200
77
82
229
VFTM-TRI 7,5
–
CTVT/8-450
F400-120
690
700
–
1,5
4.400
55
59
75
VFKB-45
–
–
CTVT/8-500
F400-120
700
770
–
2,4
7100
54
58
115
VFKB-45
CTVT/8-560
F400-120
730
1100
–
3,3
10000
58
62
129
VFKB-45
–
CTVT/8-630
F400-120
735
1650
–
4,90
14500
61
66
168
VFKB-45
–
CTVT/8-710
F400-120
VFKB-48
CTVT/4/8-225
CTVT/4/8-315
730
3160
–
7,10
19100
71
76
238
F400-120
1300/700
180/70
–
0,3/0,2
2100/1050
53/38
59/44
17
–
–
–
F400-120
1400/700
370/230
–
1,1/0,9
4200/2100
60/45
64/49
40
–
DEMA 1/1,3 DH
CTVT/4/8-400
F400-120
1400/700
560/260
–
1,3/1,0
6250/3200
67/52
70/55
52
–
DEMA 1/2,3 DH
CTVT/4/8-450
F400-120
1400/700
2400/600
–
6,1/2,5
9850/4500
70/55
74/59
77
–
DEMA 3,1/7,6 DH
CTVT/6/12-450
F400-120
960/490
500/190
–
2/1
5900/2800
59/44
63/48
80
–
DEMA 1/2,3 DH
CTVT/6/12-500
F400-120
980/490
1520/430
–
4,5/2,2
9500/4800
62/47
66/51
134
–
DEMA 2,3/5,7 DH
CTVT/6/12-560
F400-120
960/480
2400/640
–
5,6/2,2
13000/6400
66/51
70/55
134
–
DEMA 2,3/5,7 DH
CTVT/6/12-630
F400-120
960/480
4100/730
–
8,1/2,6
19500/9500
70/54
74/59
173
–
DEMA 3,1/10 DH
CTVT/6/12-710
F400-120
950/450
7300/435
–
14/5,4
25200/12700
77/63
82/67
238
–
DEMA 5,7/15,5 DH
* The ratings of sound levels are pressure values measured in dB(A) at 1,5 m at 2/3 Qmax.
** Three phase speed controllers (RMT) or inverter controller (VFKB/VFTM): Three phase 400V.
374
Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT
www.solerpalau.com
Centrifugal roof mounted fans
MAX-TEMP CTHB/CTHT - CTVB/CTVT Series
Performance curves – Horizontal discharge models
– qv: Airflow in m3/h and m3/s.
– psf: Static pressure in mmWG and Pa.
– Dry air at 20ºC and 760 mmHg.
– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
psf
(Pa)
300
psf
CTHT/CTHB - 4 pole
(mmWG)
30
225
250
25
200
20
150
15
100
51
200
53
47
180
44
140
49
46
44
10
46
50
0
5
51
0
200
300
500
0.1
psf
psf
300
30
270
27
240
24
210
21
180
18
150
15
(Pa)
12
90
9
60
6
30
3
0
0.2
psf
400
315
250
225
200
1000
62
2000 3000
0.4
5000 q [m /h]
v
0.6 0.8 1
3
62
54
53
56
www.solerpalau.com
58
55
50
0.3
60
500
50
400
40
315
300
30
250
200
20
100
10
45
52
57
2000 3000
0.5 0.7
1.0
61
67
58
60
55
57
62
1000
0.3
2000
0.4 0.5
80 630
700
70
60 560
500
50 500
62
5000
65
10000
2.0
3.0
30
200
20
100
10
0
69
24
710
210
21
630
180
18
30
3
76
20000 qv [m3/h]
5.0
240
6
q [m /s]
v
3
0
66
63
66
1000
27
60
Lp (dB(A))
59
2000 3000
0.3
5000
0.5 0.7 1.0
69
10000
2.0
73
77 83
20000 30000 qv [m3/h]
3.0
qv [m3/s]
5.0
CTHT - 12 pole (2 speed motors 6/12)
(mmWG)
9
3.0 qv [m3/s]
2.0
77
450
270
90
10000 qv [m3/h]
70
57
psf
12
1.0
61
psf
120
5000
76
68
0.2
15
0.7
72
75
0
500
150
3000
64
600
40
66
CTHT - 6 pole
800
300
71
65
400
0
200
(Pa)
70
1000
600
qv [m3/s]
Lp (dB(A))
56
51
0.2
56
60
43
70
450-T
1100 110
1000 100 710
900 90
69
5
0
500
52
CTHT/CTHB - 8 pole
350 35 560
300 30
500
250 25
200 20 450
150 15 400
100 10 315
48
0.2
(mmWG)
700
400
450 45 630
400 40
0
Lp (dB(A))
42
500
psf
80
psf psf
45
45
300
800
Lp (dB(A))
69
(Pa) (mmWG)
38
0
200
90
CTHT/CTHB - 4 pole
(mmWG)
0.2
49
40
36
900
0
56
43
psf
0.4 0.5 0.6 qv [m3/s]
47
600 60
550 55 710
500 50
50
0.3
58
2000 qv [m3/h]
54
0.1
(Pa)
52
CTHT/CTHB - 6 pole
(mmWG)
120
51
1000
psf
(Pa)
Lp (dB(A))
Lp (dB(A))
60
53
62
49
560
55
46
500
51
42
450
48
44
51
0
500
1000
0.2
0.3
2000 3000
0.5
0.7
1.0
54
58
5000
2.0
62 68
10000
qv [m3/h]
3.0
qv [m3/s]
Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT
375
Centrifugal roof mounted fans
MAX-TEMP CTHB/CTHT - CTVB/CTVT Series
Performance curves – Vertical discharge models
– qv: Airflow in m3/h and m3/s.
– psf: Static pressure in mmWG and Pa.
– Dry air at 20ºC and 760 mmHg.
– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
psf
(Pa)
300
250
200
150
psf
CTVT/CTVB - 4 pole
(mmWG)
30
25
20
51
225
200
47
53
180
140
10
50
5
0
49
44
15
100
44
46
46
49
0
200
300
psf
210
180
150
120
18
15
12
6
39
41
36
200
37
43
0
200
300
500
65
600
60
550
55
500
50
450
45 630
400
40
350
35 560
30
500
25
50
710
20 450
15
400
10
315
5
0
0
500
0.3
0.5
0.7
61
53
55
54
52
49
0.3
71
58
52
45
55
2000 3000
0.5
80
700
70
600
60
500
50
400
40
315
300
30
250
200
20
100
10
65
400
70
67
58
54
60
56
60
0
500
0
1.0
59
60
5000
63
10000
2.0
3.0
67 74
20000 qv [m3/h]
5.0
qv [m3/s]
Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT
Lp (dB(A))
68
450
1000
0.2
2000
0.3
0.5
64
3000
0.7
70
10000 qv [m3/h]
1.0
2.0
900
90
800
80 630
700
70
68
77
60
500
50 500
400
40
300
30
200
20
100
10
64
70
60
66
57
450
62
52
400
59
55
60
0
500
1000
0.2
psf
psf
270
27
240
24
210
21
180
18
150
15
560
120
12
500
90
9
450
60
6
30
3
0
75
560
600
(Pa)
3.0 qv [m3/s]
Lp (dB(A))
1100 110
0
74
5000
CTVT/CTVB - 6 pole
(Pa) (mmWG)
qv [m3/s]
Lp (dB(A))
56
50
800
3000 qv [m3/h]
2000
59
43
90
CTVT/CTVB - 4 pole
(mmWG)
54
69
1000
0.2
376
50
CTVT/CTVB - 8 pole
(mmWG)
650
100
46
1000
0.2
psf
psf
150
49
45
225
900
1000 100 710
43
250
psf
psf psf
47
315
psf
(Pa)
0.4 0.5 0.6 qv [m3/s]
3
(Pa)
200
56
2000 qv [m3/h]
Lp (dB(A))
0.1
250
0.3
21
60
300
53
CTVT/CTVB - 6 pole
(mmWG)
9
0
0.2
psf
90
30
49
1000
500
0.1
(Pa)
Lp (dB(A))
0.3
2000 3000
0.5
64
5000
1.0
67
71
75 81
10000
2.0
3.0
20000 qv [m3/h]
5.0
CTVT - 12 pole (2 speed motors 6/12)
(mmWG)
710
qv [m3/s]
Lp (dB(A))
60
53
630
62
55
49
45
51
47
42
44
49
0
500
0.2
1000
2000
0.3
0.5 0.7
52
3000
1.0
56
5000
60
66
10000 qv [m3/h]
2.0
3.0 qv [m3/s]
www.solerpalau.com
Centrifugal roof mounted fans
MAX-TEMP CTHB/CTHT - CTVB/CTVT Series
Acoustic characteristics
Sound power spectrum
To obtain the sound power spectrum, subtract the correction value shown in the following chart from the value in the technical characteristics table:
Model
HORIZONTAL DISCHARGE
Frequency bands in Hz
125
250
500
1000
2000
4000
2,0
7,5
11,0
11,0
9,0
6,0
0,5
2/3 Qmax
-0,5
3,5
5,5
5,5
3,5
0,5
-4,5
1/3 Qmax
-6,5
Qmax
Outlet
Inlet
-2,5
1,5
3,5
3,5
1,5
-1,5
Qmax
5,5
9,0
11,5
11,0
10,0
7,5
3,5
2/3 Qmax
2,5
5,0
6,0
4,5
1,5
-2,5
-8,6
1/3 Qmax
0,5
3,0
4,0
2,5
-0,5
-4,5
-10,5
125
250
500
1000
2000
4000
8000
Qmax
3,0
8,0
11,5
11,5
8,0
1,5
-8,0
2/3 Qmax
0,5
4,5
6,5
5,0
1,5
-3,0
-10,0
1/3 Qmax
-12,0
Model
VERTICAL DISCHARGE
8000
Frequency bands in Hz
Outlet
Inlet
-1,5
2,5
4,5
3,0
-0,5
-5,0
Qmax
4,5
9,0
10,5
8,5
6,5
5,5
3,0
2/3 Qmax
3,0
5,0
6,0
4,5
1,0
-3,0
-9,5
1/3 Qmax
1,0
3,0
4,0
2,5
-1,0
-5,0
-11,5
Sound power spectrum
The sound pressure spectrum, at a distance “d”, can be obtained by subtracting from each frequency band of the power spectrum, the correction value shown
in the following chart:
Distance (d)
Correction (dB)
1m
1,5m
4m
6m
10m
15m
20m
30m
11,00
14,50
23,00
26,00
31,00
34,00
37,00
40,00
Dimensions (mm)
Fan model
Ø AH
BH
4 holes
ØF
ØD
E
C
Ø AV
Ø AH
Ø AV
BH
BV
oC
Ø D*
oE
140
415
421
277
359
300
180
245
ØF
10
180
415
421
292
374
300
180
245
10
200
561
556
340
404
435
250
330
12
225
561
570
383
452
435
250
330
12
250
762
750
425
522
560
355
450
12
315
762
750
469
564
560
355
450
12
400
850
850
532
608
630
400
535
12
450
962
950
713
741
710
500
590
14
500
1214
1216
824
832
905
630
750
14
560
1214
1216
874
832
905
630
750
14
630
1336
1327
1029
1053
1100
710
840
14
710
1336
1485
1127
1161
1100
710
840
14
* Nominal accessories diameter.
BV
4 holes
ØF
ØD
E
C
www.solerpalau.com
Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT
377
Centrifugal roof mounted fans
MAX-TEMP CTHB/CTHT - CTVB/CTVT Series
Mounting accessories
Model
JMS-300
JMS-435
JMS-560
JMS-630
JMS-710
JMS-905
JMS-1100
A
B
C
F
JMS
Sealing frame
– For mounting a roof fan on an up
stand or base.
– Supplied with screws and gasket
for a complete weatherproof seal.
E
j
n
A
B
300
E
G
JPA
Accessory adapter plate
– Used when mounting the
accessories (JCA, JBR, JAE).
– Allows the fan to be disconnected
from the upstand without having to
remove the duct.
JCA
Backdraft shutter
– Prevents backdraft when the fan is
not operating.
– To be mounted at the fan inlet with
the JPA plate.
ØD (M)
C
C
ØD
nx t
H
Ø J
Ø H
Ø D
p
q
378
ØJ
ØH
E
JBR
Flange
– For use when circular connection is
required directly to the fan.
– To be mounted at the fan inlet with
the JPA plate or fixed directly to
the fan base (rivets or screws not
supplied).
ØD
JAE
Flexible coupling
– Reduces the transmission of
vibrations when the duct is
connected directly to the fan.
– To be mounted at the fan inlet with
JPA plate.
JCC
Adapter for circular duct
– For use when fitting the models up
to 400, directly to a spirally wound
circular duct.
Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT
£B
£
C
o
oA oB
Model
JBS-300
470 289
JBS-435
600 419
JBS-560
725 544
JBS-630
795 614
JBS-710
875 694
JBS-905 1065 884
JBS-1100 1260 1079
Model
JPA-300
JPA-435
JPA-560
JPA-630
JPA-710
JPA-905
JPA-1100
B
F
m
JBS
Flat roof up stand
For mounting a fan on a flat roof
without up stands.
– For use on horizontal roofs.
– Internal insulation to prevent
condensation.
– Supplied with screws and gasket for
a complete weather seal.
E
k
oA oB
470 290
600 420
725 545
795 615
875 695
1065 885
1260 1080
Model
JCA-300
JCA-435
JCA-560-N
JCA-630-N
JCA-710-N
JCA-905-N
JCA-1100-N
E
50
50
50
50
50
60
60
oC
245
330
450
535
590
750
840
oC Ø D (M)
245 10,5 (M8)
330 11 (M10)
450 11 (M10)
535 11 (M10)
590 16 (M14)
750 16 (M14)
840 16 (M14)
F
70
70
70
70
70
70
70
E
oG
300 380
300 510
300 635
300 705
300 785
400 975
400 1170
oB
oC
ØD
289
419
544
614
694
884
1079
245
330
450
535
590
750
840
182 4xM6 205
252 4xM8 280
358 8xM8 395
403 8xM10 450
503 12xM10 560
633 12xM10 690
713 16xM10 770
nxt
ØH
ØD
E
F
ØH
ØJ
182
252
358
403
503
633
713
100
145
210
240
285
345
390
124
174
227
250
300
365
410
205
280
395
450
560
690
770
219
300
415
474
581
714
806
Model
JBR-300 N
JBR-435 N
JBR-560 N
JBR-630 N
JBR-710 N
JBR-905 N
JBR-1100 N
ØD
E
ØH
ØJ
182
252
358
403
503
633
713
55
55
55
63
69
69
69
205
280
395
450
560
690
770
219
300
415
474
581
714
797
Model
JAE-300 N
JAE-435 N
JAE-560 N
JAE-630 N
JAE-710 N
JAE-905 N
JAE-1100 N
ØD
E
ØH
ØJ
182
252
358
403
503
633
713
254
254
254
254
254
254
254
205
280
395
450
560
690
770
219
300
415
474
581
714
797
Model
JCC-300
JCC-435
JCC-560
JCC-630
ØB
ØC
ØD
E
L
290
390
520
605
245
330
450
535
180
250
355
400
45
60
70
70
350
350
350
350
www.solerpalau.com
Centrifugal roof mounted fans
MAX-TEMP CTHB/CTHT - CTVB/CTVT Series
Mounting accessories
r
BI
Support base for inclined curb
mounted installations
– To ensure a proper installation
of the MAXTEMP roof fan it is
essential to specify the roof pitch
angle and the distance between
the roof beam profiles.
Model
BI-3
BI-4
BI-5
BI-6
BI-7
BI-9
BI-11
Viewed in A direction
d: Distance between the roof beam profiles
a: Roof pitch angle (curb)
l
JAA
Acoustic up stand
– Reduces in duct and radiated
noise.
– For use when mounting a fan on a
flat roof without up stands.
– Supplied with screws and gasket
for a complete weather seal.
oA oB
Model
JAA-300
470 290
JAA-435
600 419
JAA-560
725 545
JAA-630
795 615
JAA-710
875 695
JAA-905 1065 885
JAA-1100 1260 1080
oC
245
330
450
535
590
750
840
B
289
419
544
614
694
884
1079
C
245
330
450
535
590
750
840
Ø D (M)
H
oG
13 (MI0) 750 380
15 (MI2) 750 510
15 (MI2) 750 635
15 (MI2) 750 705
18 (MI4) 1000 785
18 (MI4) 1000 975
18 (MI4) 1000 1170
REVERSE MOUNTING
STANDARD MOUNTING
WITH ACCESSORIES
Acoustic attenuation in dB(A) at the corresponding frequency
band in Hz.
125
1
1
2
2
2
2
2
Model
JAA-300
JAA-435
JAA-560
JAA-630
JAA-710
JAA-905
JAA-1100
JAA Attenuator pressure drops.
15
250
5
7
8
8
8
7
7
REVERSE MOUNTING
WITH ACCESSORIES
500
13
16
16
14
14
14
16
1000
22
23
29
24
24
26
27
2000
23
25
32
27
28
30
32
4000
16
18
26
19
16
19
20
8000
12
13
17
13
11
12
13
mmWG
10
300
435
560
630
710
905
1100
5
500
www.solerpalau.com
1000
1500
2000
3000
4000
5000
10000
15000
Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT
20000 qv [m3/h]
379
Centrifugal roof mounted fans
MAX-TEMP CTHB/CTHT - CTVB/CTVT Series
Installation
➃
➀
or
➁
➂
or
or
➈
➇
➄
➆
➅
Fan
model
140
180
200
225
250
315
400
450
500
560
630
710
j
k
l
m
n
o
p
q
r
Sealing
frame
Flat roof
insulated
up stand
Acoustic
up stand
Accessory
adapter
plate
Back draft
shutter
Flange
with spigot
Flexible
coupling
Circular
adapter
Support base
for inclined curb mounted
installations
JMS-300
JBS-300
JAA-300
JPA-300
JCA-300
JBR-300 N
JAE-300 N
JCC-300
BI-3
JMS-435
JBS-435
JAA-435
JPA-435
JCA-435
JBR-435 N
JAE-435 N
JCC-435
BI-4
JMS-560
JBS-560
JAA-560
JPA-560
JCA-560-N
JBR-560 N
JAE-560 N
JCC-560
BI-5
JMS-630
JMS-710
JBS-630
JBS-710
JAA-630
JAA-710
JPA-630
JPA-710
JCA-630-N
JCA-710-N
JBR-630 N
JBR-710 N
JAE-630 N
JAE-710 N
JCC-630
–
BI-6
BI-7
JMS-905
JBS-905
JAA-905
JPA-905
JCA-905-N
JBR-905 N
JAE-905 N
–
BI-9
JMS-1100
JBS-1100
JAA-1100
JPA-1100
JCA-1100-N JBR-1100 N
JAE-1100 N
–
BI-11
Electrical accessories
380
REB
Single phase
electronic speed
controllers.
– For use with the
single phase roof
fans.
REB-5 / REB-10
Single phase
electronic speed
controllers.
– For use with the
single phase roof
fans phase roof
fans.
RMB / RMT
Auto transformer
speed controllers.
– For single phase
and three phase
roof fans models
from 140 to 400.
On/ Off Electrical
isolation switch
– Switch On/ Off 5P
(1 speed motor)
– Switch On/ Off 8P
(2 speed motor).
COM D/S
Switch
– To connect three
phase fans with
400 V motor.
– For three phase
roof fans models
from 140 to 400.
DEMA DH
Switch for 2-speed
motors with
Dahlander.
VFTM IP54
Adjustable
frequency
drives for three
phase motors from
0,37 to 15 kW.
VFKB IP65
Adjustable
frequency
drive for three phase
motors from 0,37 to
4 kW.
Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT
www.solerpalau.com
Centrifugal roof mounted fans
CTVT HP Series
F400-120
CTVT
Standard version
Range of centrifugal roof mounted fans
in vertical discharge format, designed
for smoke extraction in fire conditions
suitable for F400-120 application, base
parts manufactured in galvanised sheet
steel, cowls manufactured from spun
aluminium, centrifugal backward curved
impellers manufactured in double
coated painted sheet steel (cataphoresis
+ polyester), discharge proof guard,
and ON-OFF electrical isolator switch
incorporated.
Acoustic version (INS) with silencer
integrated at the fan discharge, to reduce
outlet noise level.
All model suitable for air stream
temperature up to 120ºC continuous.
Motors
4 pole motors, three phase 400V-50Hz,
IP55, Class F with PTC.
Speed controllable by frequency drive.
The electrical installation must be
equipped with a security system which
allows the maximum speed of the fans in
case of fire and disconects PTC.
On request
4/8 and 4/6 pole motors.
Specific applications
F400-120
Approved to
EN12101-3
standard
Certificate nº
0370-CPD-0347
CTVT INS
Acoustic version
TECHNICAL CHARACTERISTICS
Model type
Speed
(rpm)
Maximum
absorbed power
(kW)
Maximum
absorbed current
400V (A)
Maximum
airflow
(m3/h)
SPL*
(dB(A))
Outlet
Weight
(kg)
Standard version
CTVT/4-632 5,5KW
1465
6,10
10,9
18.000
83
177
CTVT/4-631 7,5KW
1480
6,67
12,4
20.700
85
180
CTVT/4-712 11KW
1470
12,25
21,3
26.000
90
267
CTVT/4-711 15KW
1480
16,39
29,5
32.500
90
303
CTVT/4-802 18,5KW
1480
19,85
34,5
35.400
91
361
CTVT/4-801 22KW
1485
26,00
43,6
44.500
94
376
Acoustic version (INS)
CTVT/4-632 5,5KW INS
1465
6,10
10,9
18.000
70
221
CTVT/4-631 7,5KW INS
1480
6,67
12,4
20.700
77
224
CTVT/4-712 11KW INS
1470
12,25
21,3
26.000
82
357
CTVT/4-711 15KW INS
1480
16,39
29,5
32.500
83
393
CTVT/4-802 18,5KW INS
1480
19,85
34,5
35.400
83
492
CTVT/4-801 22KW INS
1485
26,00
43,6
44.500
87
507
* Max. sound pressure level measured at 3m, in hemispherical radiation.
www.solerpalau.com
Roof mounted fans CTVT HP
Centrifugal roof mounted fans
CTVT HP Series
PERFORMANCE CURVES - ACOUSTIC CHARACTERISTICS
–qv: Airflow in m3/h.
–psf: Static pressure in Pa.
–P: Input power in W.
–Sound pressure level @ 3 m, hemispherical radiation, in dB(A).
–Performance data in accordance with ISO 5801.
CTVT/4-632
5,55,5kW
kW
CTV
T/4-632
CTVT/4-631
kW
CTV
T/4-6317,57,5kW
psf
psf
[Pa]
[Pa]
50H
1000
50 Hz
1000
z
80
81
800
800
40H
40 Hz
z
600
75
600
81
76
83
400
30Hz
76
69
25Hz
70
70
P [W]
6000
68
0
4000
66
200
66
8000
72
0
12000
72
68
83
79
0
16000
qv [m3/h]
50Hz
P [W]
6000
0
4000
8000
40Hz
2000
30Hz
30Hz
25Hz
0
0
4000
8000
12000
16000
qv [m
3
/h]
Sound power spectrum: Standard version sound power spectrum LwA, at the fan outlet.
OUTPUT
30Hz
25Hz
qv [m3/h]
50Hz
25Hz
40Hz
12000 16000 20000
40Hz
2000
50Hz
85
80
74
70
4000
4000
0
78
25 Hz
65
200
3 0 Hz
400
63
125
250
500 1000 2000 4000 8000 STD* INS*
LP
78
85
96
93
93
95
87
77
101
87
MP
74
84
95
90
90
90
82
73
98
88
HP
75
83
94
90
90
89
81
75
98
87
LP
73
80
91
88
88
90
83
72
96
83
MP
69
79
90
86
85
85
77
68
93
83
HP
70
78
89
85
85
84
76
70
93
83
LP
67
74
85
82
82
84
76
66
90
76
MP
63
73
84
79
79
78
71
62
87
76
HP
64
72
83
79
79
78
70
63
87
76
LP
63
70
81
78
78
80
72
62
86
72
MP
59
69
80
75
75
74
67
58
83
73
HP
60
68
79
75
75
74
66
59
83
72
* STD: Standard version - INS: Acoustic version
Roof mounted fans CTVT HP
0
4000
8000
12000 16000 20000
qv [m3/h]
Sound power spectrum: Standard version sound power spectrum LwA, at the fan outlet.
OUTPUT
50Hz
40Hz
30Hz
25Hz
63
125
250
500 1000 2000 4000 8000 STD*
INS*
LP
71
79
95
93
94
99
93
83
103
94
MP
69
79
95
92
94
94
86
81
100
96
HP
68
78
95
90
92
89
82
79
98
98
LP
66
74
90
88
89
94
88
78
98
90
MP
64
74
90
87
89
89
81
76
95
91
HP
63
73
90
85
87
84
77
74
93
93
LP
60
68
84
82
83
88
82
72
92
83
MP
58
68
84
81
83
83
75
70
89
85
HP
57
67
84
79
81
78
71
68
87
87
LP
56
64
80
78
79
84
78
68
88
79
MP
54
64
80
77
79
79
71
66
85
81
HP
53
63
80
75
77
74
67
64
83
83
* STD: Standard version - INS: Acoustic version
www.solerpalau.com
Centrifugal roof mounted fans
CTVT HP Series
PERFORMANCE CURVES - ACOUSTIC CHARACTERISTICS
–qv: Airflow in m3/h.
–psf: Static pressure in Pa.
–P: Input power in W.
–Sound pressure level @ 3 m, hemispherical radiation, in dB(A).
–Performance data in accordance with ISO 5801.
CTV
T/4-711
15kW
CTVT/4-711
15kW
CTV
T/4-71211kW
11kW
CTVT/4-712
psf
psf
[Pa]
[Pa]
1400
50Hz
1400
5 0Hz
82
81
1200
1200
1000
1000
40Hz
76
800
600
85
85
600
30Hz
70
400
25Hz
66
0
P [W]
400
74
200
10000 15000 20000 25000
qv[m3/h]
50Hz
0
10000
20000
30000
qv[m3/h]
50Hz
25Hz
0
5000
OUTPUT
10000 15000 20000 25000
63
125
500 1000 2000 4000 8000 STD* INS*
LP
78
90
97
100
102
102
97
88
107
100
MP
74
86
93
96
98
94
88
80
102
94
HP
73
87
90
93
94
89
83
75
98
89
LP
73
85
92
95
97
97
93
83
102
95
MP
69
81
88
91
94
89
84
75
97
89
HP
68
83
85
88
89
84
79
71
94
85
LP
67
79
86
88
91
91
86
77
96
89
MP
63
74
81
85
87
83
77
69
91
83
HP
62
76
79
82
83
78
72
64
87
78
LP
63
75
82
85
87
87
82
73
92
85
MP
59
70
77
81
83
79
73
65
87
79
HP
58
72
75
78
79
74
68
60
83
74
www.solerpalau.com
0
qv[m3/h]
250
* STD: Standard version - INS: Acoustic version
40Hz
30Hz
4000
30Hz
Sound power spectrum: Standard version sound power spectrum LwA, at the fan outlet.
25Hz
P [W]
8000
40Hz
3000
30Hz
0
79
12000
6000
40Hz
85
75
16000
9000
50Hz
90
70
79
12000
0
67
200
85
75
5000
25Hz
80
71
74
90
70
0
77
800
80
30Hz
40Hz
25Hz
0
10000
20000
30000
qv[m3/h]
Sound power spectrum: Standard version sound power spectrum LwA, at the fan outlet.
OUTPUT
50Hz
40Hz
30Hz
25Hz
63
125
250
500 1000 2000 4000 8000 STD* INS*
LP
78
88
100
101
101
101
98
89
107
100
MP
73
88
97
96
96
91
93
81
102
94
HP
69
86
95
93
93
88
89
77
100
91
LP
74
84
95
96
96
96
94
84
102
95
MP
69
83
92
91
92
87
88
76
98
89
HP
65
81
90
88
89
84
84
72
95
86
LP
67
77
89
90
90
90
87
78
96
89
MP
62
77
86
85
85
80
82
70
91
83
HP
58
75
84
82
82
77
78
66
89
80
LP
63
73
85
86
86
86
83
74
92
85
MP
58
73
82
81
81
76
78
66
87
79
HP
54
71
80
78
78
73
74
62
85
76
* STD: Standard version - INS: Acoustic version
Roof mounted fans CTVT HP
Centrifugal roof mounted fans
CTVT HP Series
PERFORMANCE CURVES - ACOUSTIC CHARACTERISTICS
–qv: Airflow in m3/h.
–psf: Static pressure in Pa.
–P: Input power in W.
–Sound pressure level @ 3 m, hemispherical radiation, in dB(A).
–Performance data in accordance with ISO 5801.
CTV T/4-801
22kW
CTVT/4-801
22kW
CTV
T/4-80218,5kW
18,5kW
CTVT/4-802
psf
[Pa]
psf
50Hz
[Pa]
50Hz
1600
1600
82
1400
1400
1200
1200
87
40 Hz
40Hz
1000
78
1000
86
800
30Hz
400
25Hz
67
76
10000
20000
200
30000
qv[m
3
0
/h]
P [W]
25000
16000
20000
12000
15000
8000
10000
4000
5000
0
0
10000
20000
30000
qv[m3/h]
Sound power spectrum: Standard version sound power spectrum LwA, at the fan outlet.
OUTPUT
50Hz
40Hz
30Hz
25Hz
63
125
80
250
500 1000 2000 4000 8000 STD* INS*
LP
79
90
97
101
102
103
99
90
108
101
MP
75
86
93
99
98
96
91
82
103
97
HP
74
87
90
96
94
91
86
79
100
94
LP
74
86
92
97
97
99
95
85
103
96
MP
70
82
89
94
93
91
86
77
99
92
HP
69
82
86
91
89
87
82
74
95
90
LP
68
79
85
90
91
92
88
79
97
90
MP
64
75
82
88
87
85
80
71
92
86
HP
63
76
79
85
83
80
75
68
89
89
LP
64
75
82
86
87
88
84
75
93
86
MP
60
71
78
84
83
81
76
67
88
82
HP
59
72
75
81
79
76
71
64
85
79
* STD: Standard version - INS: Acoustic version
Roof mounted fans CTVT HP
94
76
80
20000
0
72
91
86
86
76
25 Hz
400
75
71
0
30 Hz
600
81
71
200
P [W]
91
800
600
0
82
89
79
0
10000
20000
83
30000
40000
qv[m3/h]
50Hz
40Hz
30Hz
25Hz
0
10000
20000
30000
40000
qv[m3/h]
Sound power spectrum: Standard version sound power spectrum LwA, at the fan outlet.
OUTPUT
50Hz
40Hz
30Hz
25Hz
63
125
250
500 1000 2000 4000 8000 STD* INS*
LP
80
93
101
104
108
103
101
89
112
104
MP
79
90
98
101
106
100
94
85
108
102
HP
76
89
93
98
102
94
86
81
104
98
LP
76
88
96
99
104
98
96
84
107
99
MP
74
85
93
96
101
95
89
80
104
97
HP
71
84
88
93
97
90
82
76
99
93
LP
69
82
90
92
97
92
90
78
100
93
MP
68
79
87
90
95
89
83
74
97
91
HP
65
78
82
87
90
83
75
70
93
87
LP
65
78
86
88
93
88
86
74
96
89
MP
64
75
83
86
91
85
79
70
93
87
HP
61
74
78
83
87
79
71
66
89
83
* STD: Standard version - INS: Acoustic version
www.solerpalau.com
Centrifugal roof mounted fans
CTVT HP Series
DIMENSIONS (mm)
CTVT Standard version
Ø AV
Model
AV
BV
C
E
CTVT/4-632 5,5KW
1216
930
905
750
CTVT/4-631 7,5KW
1216
930
905
750
CTVT/4-712 11KW
1485
1146
1270
950
CTVT/4-711 15KW
1485
1188
1270
950
1485
1207
1270
950
1485
1225
1270
950
BV
C
E
BV
CTVT/4-802 18,5KW
CTVT/4-801 22KW
4 Ø 14
E
C
CTVT INS Acoustic version
Ø AV
Model
AV
CTVT/4-632 5,5KW INS
1342
978
905
750
CTVT/4-631 7,5KW INS
1342
978
905
750
CTVT/4-712 11KW INS
1611
1163
1270
950
CTVT/4-711 15KW INS
1611
1250
1270
950
1611
1274
1270
950
CTVT/4-801 22KW INS
1611
1292
1270
950
BV
CTVT/4-802 18,5KW INS
4 Ø 14
E
C
www.solerpalau.com
Roof mounted fans CTVT HP
Centrifugal roof mounted fans
CTVT HP Series
Mounting accessories
JPA
Accessory adapter plate
– Used when mounting the
accessories (JCA, JBR, JAE).
– Allows the fan to be
disconnected from the upstand
without having to remove the
duct.
JCA N
Backdraft shutter
– Prevents backdraft when the
fan is not operating.
– To be mounted at the fan inlet
with the JPA plate.
A
B
C
E
F
JMS-905
1065
885
750
60
70
JMS-1250
1410
1230
950
60
70
F
E
C
A
B
Ø D (M)
E
Model
A
B
JBS-905
1065
884 750 16 (M10) 400
C
G
975
JBS-V-1000 1447 1247 950 18 (M12) 400 1347
E
ØD (M)
C
G
Model
B
C
ØD
nxt
B
JPA-905
884
750
633
12xM10
ØH
690
C
JPA-1250
1230
950
1000
8xM12
1070
ØJ
ØD
nx t
H
Ø J
Ø H
F
JBS/JBS-V
Flat roof up stand
– For mounting a fan on a flat
roofwithout up stands.
– For use on horizontal roofs.
– Internal insulation to prevent
condensation.
– Supplied with screws and gasket
for a complete weather seal.
A
B
Model
Model
ØD
E
F
ØH
JCA-905 N
633
345
365
690
714
JCA-1250 N
1004
560
560
1070
1110
E
JMS
Sealing frame
– For mounting a roof fan on an
up stand or base.
– Supplied with screws and
gasket for a complete
weatherproof seal.
Ø D
JAE N
Flexible coupling
– Reduces the transmission of
vibrations when the duct is
connected directly to the fan.
– To be mounted at the fan inlet
with JPA plate.
Roof mounted fans CTVT HP
Model
ØD
E
ØH
ØJ
JBR-905 N
633
55
690
ØJ
714
ØH
JBR-1250 N
1004
60
1070
1110
Model
ØD
E
ØH
ØJ
JAE-905 N
633
164
690
714
JAE-1250 N
1004
185
1070
1110
E
JBR N
Flange
– For use when circular connection is
required directly to the fan.
– To be mounted at the fan inlet with
the JPA plate or fixed directly to
the fan base (rivets or screws not
supplied).
ØD
www.solerpalau.com
Centrifugal roof mounted fans
CTVT HP Series
Mounting accessories - INSTALLATION
3
1
or
2
4
6
5
Fan model
CTVT/4-632
CTVT/4-631
1
Sealing
frame
2
Flat roof
insulated
up stand
3
Accessory
adapter
plate
4
Back draft
shutter
5
Flange
with spigot
6
Flexible
coupling
JMS-905
JBS-905
JPA-905
JCA-905 N
JBR-905 N
JAE-905 N
JMS-1250
JBS-V-1000
JPA-1250
JCA-1250 N
JBR-1250 N
JAE-1250 N
CTVT/4-712
CTVT/4-711
CTVT/4-802
CTVT/4-801
www.solerpalau.com
Roof mounted fans CTVT HP

Similar documents

details

details Technical characteristics for models with horizontal discharge CTHB/ CTHT Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequ...