Centrifugal roof mounted fans MAX
Transcription
Centrifugal roof mounted fans MAX
Centrifugal roof mounted fans MAX-TEMP CTHB / CTHT Series - Horizontal discharge F400-120 Range of centrifugal roof mounted fans in horizontal discharge format, designed for smoke extraction in fire conditions and certified F400-120 (CE marked) (1). All models are suitable for air stream temperature up to 120ºC. Bases are manufactured from galvanised sheet steel and cowls are manufactured from spun aluminium. All models incorporate bird-proof guard. Available, depending upon the model, with single or three phase motors in 4, 6, 8, 4/8 or 6/12 poles. (1) Except 140, 180 and 200 models. Motors All motors are IP55, Class F and equipped with ball bearings greased for life. Electrical supply: Single phase 230V-50Hz. Three phase 400V-50Hz. (See characteristics chart). Speed controllable by voltage, up to 400 model. Three phase motors are controllable by frequency inverter. When is using a speed controller, the electrical installation must be equipped with a security system which allows the maximum speed of the fans in cas of fire. Additional information 140, 180, 200 and 225 models are specially recommended for extracting smoke from the fireplaces. Only F400-120 at maximum fan speed. Specific applications F400-120 Easy to install Supports easing the installation on the roof. Self cooling system Special design in order to cool the motor and to extend the life of the assembly. Bird-proof guard. Approved to Continuous EN12101-3 operation standard Certificate nº 0370-CPD-0347 Car Parks Industrial and commercial kitchens Additional applications for 140,180,200 and 225 models Continuous Smoke extract Backward curved centrifugal impellers To prevent accumulation of dirt. Models up to 400 are manufactured from galvanised steel sheet. Models from 450 to 630 are manufactured in sheet steel protected against corrosion by cataforesis primer and black polyester paint finish. www.solerpalau.com Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT 371 Centrifugal roof mounted fans MAX-TEMP CTVB / CTVT Series - Vertical discharge F400-120 Range of centrifugal roof mounted fans in vertical discharge format, designed for smoke extraction in fire conditions and certified F400-120 (CE marked) (1). All models are suitable for air stream temperature up to 120ºC. Bases are manufactured from galvanised sheet steel and cowls are manufactured from spun aluminium. All models incorporate bird-proof guard. Available, depending upon the model, with single or three phase motors in 4, 6, 8, 4/8 or 6/12 poles. (1) Except 140, 180 and 200 models. Motors All motors are IP55, Class F and equipped with ball bearings greased for life. Electrical supply: Single phase 230V-50Hz. Three phase 400V-50Hz. (See characteristics chart). Speed controllable by voltage, up to 400 model. Three phase motors are controllable by frequency inverter. When is using a speed controller, the electrical installation must be equipped with asecurity system which allows the maximum speed of the fans in cas of fire. Models configuration 140 to 400 Additional information 140, 180, 200 and 225 models are specially recommended for extracting smoke from the fireplaces. Models configuration 450 to 710 Only F400-120 at maximum fan speed. Specific applications Cooling duct Enables the motor cooling when the fan is extracting air at an extremely high temperature. Easy to install Supports easing the installation on the roof. Self cooling system Special design in order to cool the motor and to extend the life of the assembly. F400-120 Approved to Continuous EN12101-3 operation standard Certificate nº 0370-CPD-0347 Car Parks Industrial and commercial kitchens Additional applications for 140,180,200 and 225 models Continuous Backward curved centrifugal impellers To prevent accumulation of dirt. Models up to 400 are manufactured from galvanised steel sheet. Models from 450 to 630 are manufactured in sheet steel protected against corrosion by cataforesis primer and black polyester paint finish. 372 Smoke extract Bird-proof guard. Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT www.solerpalau.com Centrifugal roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT Series Technical characteristics for models with horizontal discharge CTHB/ CTHT Before installation check that the product electrical characteristics listed on the data plate label (voltage, power, frequency, etc.) match those of the intended electrical supply. 6 poles single phase 4 poles single phase Model Speed (rpm) 4 poles three phase 6 poles three phase Maximum airflow (m3/h) Sound pressure level* at 2/3 Qmax (dB(A)) Speed controllable (**) Switch for 2-speed motors at 230 V at 400 V 60 0,32 – 800 46 52 7,5 REB-1N – CTHB/4-180 1330 70 0,33 – 990 46 52 8 REB-1N – CTHB/4-200 CTHB/4-225 F400-120 Inlet Weight (kg) 1370 Outlet 1320 120 0,60 – 1450 49 55 14,2 REB-1N – 1350 170 0,90 – 2100 53 59 17 REB-2,5N – CTHB/4-250 F400-120 1320 280 1,40 – 3100 57 62 28 REB-2,5N – CTHB/4-315 F400-120 1375 590 2,70 – 4900 60 66 32 REB-5 – CTHB/4-400 F400-120 1380 1100 5,30 – 7000 67 73 42,5 REB-10 – 940 80 0,40 – 970 38 45 14,2 REB-1N – CTHB/6-200 CTHB/6-225 F400-120 890 90 0,40 – 1400 42 48 17 REB-1N – CTHB/6-250 F400-120 940 100 0,57 – 2000 45 52 28 REB-1N – CTHB/6-315 F400-120 840 170 0,81 – 3200 49 55 32 REB-1N – F400-120 950 350 1,60 – 4500 56 62 42,5 REB-2,5N – 1375 60 – 0,17 800 46 52 7,5 RMT-1,5 – CTHB/6-400 CTHT/4-180 1350 70 – 0,17 990 46 52 8 RMT-1,5 – CTHT/4-200 1340 130 – 0,35 1450 49 55 14,2 RMT-1,5 – CTHT/4-225 F400-120 1360 170 – 0,50 2100 53 59 17 RMT-1,5 – CTHT/4-250 F400-120 1400 300 – 0,80 3100 57 62 28 RMT-1,5 – CTHT/4-315 F400-120 1410 620 – 1,50 4900 60 66 32 RMT-2,5 – CTHT/4-400 F400-120 1350 920 – 1,80 7000 67 73 42,5 RMT-2,5 – CTHT/4-450 F400-120 1440 2300 – 4,60 10200 71 76 67 VFKB-48 – 950 80 – 0,24 970 38 45 14,2 RMT-1,5 – CTHT/6-225 F400-120 900 90 – 0,23 1400 42 48 17 RMT-1,5 – CTHT/6-250 F400-120 950 100 – 0,41 2000 45 52 28 RMT-1,5 – CTHT/6-200 8 poles three phase Maximum absorbed current (A) CTHB/4-140 CTHT/4-140 2 speeds three phase Maximum absorbed power (W) CTHT/6-315 F400-120 900 180 – 0,50 3200 49 55 32 RMT-1,5 – CTHT/6-400 F400-120 925 350 – 1,00 4500 56 62 42,5 RMT-1,5 – CTHT/6-450 F400-120 940 850 – 3,50 6900 59 66 67 VFKB-45 – CTHT/6-500 F400-120 965 1400 – 4,30 10500 63 69 104 VFKB-45 – CTHT/6-560 F400-120 950 2400 – 5,30 16000 66 73 118 VFKB-48 – CTHT/6-630 F400-120 950 3700 – 8,30 21000 70 76 156 VFTM-TRI 4 – CTHT/6-710 F400-120 980 6800 – 13,80 28900 77 83 217 VFTM-TRI 7,5 – CTHT/8-450 F400-120 700 700 – 2,10 5000 55 61 67 VFKB-45 – CTHT/8-500 F400-120 725 770 – 2,40 7500 55 62 104 VFKB-45 – CTHT/8-560 F400-120 730 1100 – 3,60 11500 58 65 118 VFKB-45 – CTHT/8-630 F400-120 735 1650 – 4,90 15000 62 69 156 VFKB-48 – CTHT/8-710 F400-120 730 2900 – 7,20 21700 70 76 226 VFKB-48 – CTHT/4/8-225 F400-120 1300/700 180/70 – 0,3/0,2 2100/1050 53/38 59/44 17 – – CTHT/4/8-315 F400-120 1400/700 370/230 – 1,1/0,9 4900/2400 60/45 66/51 33 – DEMA 1/1,3 DH CTHT/4/8-400 F400-120 1400/700 1000/260 – 1,8/1,0 7000/3500 67/52 73/58 44 – DEMA 1/2,3 DH CTHT/4/8-450 F400-120 1400/700 2400/600 – 6,1/2,5 10200/5100 71/55 76/61 69 – DEMA 3,1/7,6 DH CTHT/6/12-450 F400-120 960/490 500/190 – 2/1 6900/3400 59/44 66/51 72 – DEMA 1/2,3 DH CTHT/6/12-500 F400-120 980/490 1520/430 – 4,5/2,2 10500/5300 63/48 69/54 109 – DEMA 2,3/5,7 DH CTHT/6/12-560 F400-120 950/480 2400/640 – 5,6/2,2 16000/7000 66/51 73/58 124 – DEMA 2,3/5,7 DH CTHT/6/12-630 F400-120 960/480 4100/730 – 8,1/2,6 21000/10500 70/55 76/61 161 – DEMA 3,1/10 DH F400-120 950/450 6700/850 – 14,1/5,4 28900/15000 77/62 83/68 226 – DEMA 5,7/15,5 DH CTHT/6/12-710 * The ratings of sound levels are pressure values measured in dB(A) at 1,5 m at 2/3 Qmax. ** Three phase speed controllers (RMT) or inverter controller (VFKB/VFTM): Three phase 400V. www.solerpalau.com Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT 373 Centrifugal roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT Series Technical characteristics for models with vertical discharge CTVB/ CTVT Before installation check that the product electrical characteristics listed on the data plate label (voltage, power, frequency, etc.) match those of the intended electrical supply. 4 poles three phase 6 poles single phase 4 poles single phase Model 6 poles three phase 8 poles three phase Maximum airflow (m3/h) Sound pressure level* at 2/3 Qmax (dB(A)) Weight (kg) Speed controllable (**) Switch for 2-speed motors Maximum absorbed power (W) at 230 V at 400 V CTVB/4-140 1375 60 0,3 – 725 46 49 10 REB-1N – CTVB/4-180 1330 60 0,3 – 830 46 49 10,5 REB-1N – CTVB/4-200 Inlet Outlet 1330 100 0,60 – 1320 49 53 17 REB-1N – CTVB/4-225 F400-120 1350 130 0,71 – 1900 53 56 19,8 REB-1N – CTVB/4-250 F400-120 1325 325 1,6 – 2800 56 60 35 REB-2,5N – CTVB/4-315 F400-120 1390 570 2,70 – 4200 60 64 39 REB-5 – CTVB/4-400 F400-120 1390 1100 5,30 – 6250 67 70 50 REB-10 – 940 80 0,40 – 900 38 42 17 REB-1N – CTVB/6-225 F400-120 890 90 0,40 – 1300 41 45 19,8 REB-1N – CTVB/6-250 F400-120 940 100 0,57 – 1850 45 49 35 REB-1N – CTVB/6-315 F400-120 870 160 0,80 – 2800 48 53 39 REB-1N – CTVB/6-400 F400-120 960 340 1,60 – 4300 55 59 50 REB-2,5N – CTVB/6-200 CTVT/4-140 1400 60 – 0,18 725 46 49 10 RMT-1,5 – CTVT/4-180 1350 60 – 0,18 830 46 49 10,5 RMT-1,5 – CTVT/4-200 1340 130 – 0,44 1200 49 53 17 RMT-1,5 – CTVT/4-225 F400-120 1360 180 – 0,47 1900 53 56 19,8 RMT-1,5 – CTVT/4-250 F400-120 1400 300 – 0,8 2800 56 60 35 RMT-1,5 – CTVT/4-315 F400-120 1410 400 – 1,4 4200 60 64 39 RMT-2,5 – CTVT/4-400 F400-120 1330 1000 – 1,80 6250 67 70 50 RMT-2,5 – CTVT/4-450 F400-120 1440 2100 – 4,3 8850 70 74 75 VFKB-45 – 950 80 – 0,24 900 38 42 17 RMT-1,5 – CTVT/6-200 2 speeds three phase Maximum absorbed current (A) Speed (rpm) CTVT/6-225 F400-120 900 90 – 0,23 1300 41 45 19,8 RMT-1,5 – CTVT/6-250 F400-120 950 100 – 0,41 1850 45 49 35 RMT-1,5 – CTVT/6-315 F400-120 910 160 – 0,44 2800 48 53 39 RMT-1,5 – CTVT/6-400 F400-120 930 350 – 1,00 4300 55 59 50 RMT-1,5 – CTVT/6-450 F400-120 950 800 – 3,5 5900 59 63 75 VFKB-45 – CTVT/6-500 F400-120 975 1500 – 3,7 9500 62 66 115 VFKB-45 – CTVT/6-560 F400-120 950 2400 – 5,50 13000 66 70 129 VFKB-48 – CTVT/6-630 F400-120 950 3900 – 8,3 19500 70 74 168 VFTM-TRI 4 – CTVT/6-710 F400-120 980 7250 – 13,6 25200 77 82 229 VFTM-TRI 7,5 – CTVT/8-450 F400-120 690 700 – 1,5 4.400 55 59 75 VFKB-45 – – CTVT/8-500 F400-120 700 770 – 2,4 7100 54 58 115 VFKB-45 CTVT/8-560 F400-120 730 1100 – 3,3 10000 58 62 129 VFKB-45 – CTVT/8-630 F400-120 735 1650 – 4,90 14500 61 66 168 VFKB-45 – CTVT/8-710 F400-120 VFKB-48 CTVT/4/8-225 CTVT/4/8-315 730 3160 – 7,10 19100 71 76 238 F400-120 1300/700 180/70 – 0,3/0,2 2100/1050 53/38 59/44 17 – – – F400-120 1400/700 370/230 – 1,1/0,9 4200/2100 60/45 64/49 40 – DEMA 1/1,3 DH CTVT/4/8-400 F400-120 1400/700 560/260 – 1,3/1,0 6250/3200 67/52 70/55 52 – DEMA 1/2,3 DH CTVT/4/8-450 F400-120 1400/700 2400/600 – 6,1/2,5 9850/4500 70/55 74/59 77 – DEMA 3,1/7,6 DH CTVT/6/12-450 F400-120 960/490 500/190 – 2/1 5900/2800 59/44 63/48 80 – DEMA 1/2,3 DH CTVT/6/12-500 F400-120 980/490 1520/430 – 4,5/2,2 9500/4800 62/47 66/51 134 – DEMA 2,3/5,7 DH CTVT/6/12-560 F400-120 960/480 2400/640 – 5,6/2,2 13000/6400 66/51 70/55 134 – DEMA 2,3/5,7 DH CTVT/6/12-630 F400-120 960/480 4100/730 – 8,1/2,6 19500/9500 70/54 74/59 173 – DEMA 3,1/10 DH CTVT/6/12-710 F400-120 950/450 7300/435 – 14/5,4 25200/12700 77/63 82/67 238 – DEMA 5,7/15,5 DH * The ratings of sound levels are pressure values measured in dB(A) at 1,5 m at 2/3 Qmax. ** Three phase speed controllers (RMT) or inverter controller (VFKB/VFTM): Three phase 400V. 374 Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT www.solerpalau.com Centrifugal roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT Series Performance curves – Horizontal discharge models – qv: Airflow in m3/h and m3/s. – psf: Static pressure in mmWG and Pa. – Dry air at 20ºC and 760 mmHg. – Performance data in accordance with ISO 5801 and AMCA 210-99 Standards. psf (Pa) 300 psf CTHT/CTHB - 4 pole (mmWG) 30 225 250 25 200 20 150 15 100 51 200 53 47 180 44 140 49 46 44 10 46 50 0 5 51 0 200 300 500 0.1 psf psf 300 30 270 27 240 24 210 21 180 18 150 15 (Pa) 12 90 9 60 6 30 3 0 0.2 psf 400 315 250 225 200 1000 62 2000 3000 0.4 5000 q [m /h] v 0.6 0.8 1 3 62 54 53 56 www.solerpalau.com 58 55 50 0.3 60 500 50 400 40 315 300 30 250 200 20 100 10 45 52 57 2000 3000 0.5 0.7 1.0 61 67 58 60 55 57 62 1000 0.3 2000 0.4 0.5 80 630 700 70 60 560 500 50 500 62 5000 65 10000 2.0 3.0 30 200 20 100 10 0 69 24 710 210 21 630 180 18 30 3 76 20000 qv [m3/h] 5.0 240 6 q [m /s] v 3 0 66 63 66 1000 27 60 Lp (dB(A)) 59 2000 3000 0.3 5000 0.5 0.7 1.0 69 10000 2.0 73 77 83 20000 30000 qv [m3/h] 3.0 qv [m3/s] 5.0 CTHT - 12 pole (2 speed motors 6/12) (mmWG) 9 3.0 qv [m3/s] 2.0 77 450 270 90 10000 qv [m3/h] 70 57 psf 12 1.0 61 psf 120 5000 76 68 0.2 15 0.7 72 75 0 500 150 3000 64 600 40 66 CTHT - 6 pole 800 300 71 65 400 0 200 (Pa) 70 1000 600 qv [m3/s] Lp (dB(A)) 56 51 0.2 56 60 43 70 450-T 1100 110 1000 100 710 900 90 69 5 0 500 52 CTHT/CTHB - 8 pole 350 35 560 300 30 500 250 25 200 20 450 150 15 400 100 10 315 48 0.2 (mmWG) 700 400 450 45 630 400 40 0 Lp (dB(A)) 42 500 psf 80 psf psf 45 45 300 800 Lp (dB(A)) 69 (Pa) (mmWG) 38 0 200 90 CTHT/CTHB - 4 pole (mmWG) 0.2 49 40 36 900 0 56 43 psf 0.4 0.5 0.6 qv [m3/s] 47 600 60 550 55 710 500 50 50 0.3 58 2000 qv [m3/h] 54 0.1 (Pa) 52 CTHT/CTHB - 6 pole (mmWG) 120 51 1000 psf (Pa) Lp (dB(A)) Lp (dB(A)) 60 53 62 49 560 55 46 500 51 42 450 48 44 51 0 500 1000 0.2 0.3 2000 3000 0.5 0.7 1.0 54 58 5000 2.0 62 68 10000 qv [m3/h] 3.0 qv [m3/s] Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT 375 Centrifugal roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT Series Performance curves – Vertical discharge models – qv: Airflow in m3/h and m3/s. – psf: Static pressure in mmWG and Pa. – Dry air at 20ºC and 760 mmHg. – Performance data in accordance with ISO 5801 and AMCA 210-99 Standards. psf (Pa) 300 250 200 150 psf CTVT/CTVB - 4 pole (mmWG) 30 25 20 51 225 200 47 53 180 140 10 50 5 0 49 44 15 100 44 46 46 49 0 200 300 psf 210 180 150 120 18 15 12 6 39 41 36 200 37 43 0 200 300 500 65 600 60 550 55 500 50 450 45 630 400 40 350 35 560 30 500 25 50 710 20 450 15 400 10 315 5 0 0 500 0.3 0.5 0.7 61 53 55 54 52 49 0.3 71 58 52 45 55 2000 3000 0.5 80 700 70 600 60 500 50 400 40 315 300 30 250 200 20 100 10 65 400 70 67 58 54 60 56 60 0 500 0 1.0 59 60 5000 63 10000 2.0 3.0 67 74 20000 qv [m3/h] 5.0 qv [m3/s] Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT Lp (dB(A)) 68 450 1000 0.2 2000 0.3 0.5 64 3000 0.7 70 10000 qv [m3/h] 1.0 2.0 900 90 800 80 630 700 70 68 77 60 500 50 500 400 40 300 30 200 20 100 10 64 70 60 66 57 450 62 52 400 59 55 60 0 500 1000 0.2 psf psf 270 27 240 24 210 21 180 18 150 15 560 120 12 500 90 9 450 60 6 30 3 0 75 560 600 (Pa) 3.0 qv [m3/s] Lp (dB(A)) 1100 110 0 74 5000 CTVT/CTVB - 6 pole (Pa) (mmWG) qv [m3/s] Lp (dB(A)) 56 50 800 3000 qv [m3/h] 2000 59 43 90 CTVT/CTVB - 4 pole (mmWG) 54 69 1000 0.2 376 50 CTVT/CTVB - 8 pole (mmWG) 650 100 46 1000 0.2 psf psf 150 49 45 225 900 1000 100 710 43 250 psf psf psf 47 315 psf (Pa) 0.4 0.5 0.6 qv [m3/s] 3 (Pa) 200 56 2000 qv [m3/h] Lp (dB(A)) 0.1 250 0.3 21 60 300 53 CTVT/CTVB - 6 pole (mmWG) 9 0 0.2 psf 90 30 49 1000 500 0.1 (Pa) Lp (dB(A)) 0.3 2000 3000 0.5 64 5000 1.0 67 71 75 81 10000 2.0 3.0 20000 qv [m3/h] 5.0 CTVT - 12 pole (2 speed motors 6/12) (mmWG) 710 qv [m3/s] Lp (dB(A)) 60 53 630 62 55 49 45 51 47 42 44 49 0 500 0.2 1000 2000 0.3 0.5 0.7 52 3000 1.0 56 5000 60 66 10000 qv [m3/h] 2.0 3.0 qv [m3/s] www.solerpalau.com Centrifugal roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT Series Acoustic characteristics Sound power spectrum To obtain the sound power spectrum, subtract the correction value shown in the following chart from the value in the technical characteristics table: Model HORIZONTAL DISCHARGE Frequency bands in Hz 125 250 500 1000 2000 4000 2,0 7,5 11,0 11,0 9,0 6,0 0,5 2/3 Qmax -0,5 3,5 5,5 5,5 3,5 0,5 -4,5 1/3 Qmax -6,5 Qmax Outlet Inlet -2,5 1,5 3,5 3,5 1,5 -1,5 Qmax 5,5 9,0 11,5 11,0 10,0 7,5 3,5 2/3 Qmax 2,5 5,0 6,0 4,5 1,5 -2,5 -8,6 1/3 Qmax 0,5 3,0 4,0 2,5 -0,5 -4,5 -10,5 125 250 500 1000 2000 4000 8000 Qmax 3,0 8,0 11,5 11,5 8,0 1,5 -8,0 2/3 Qmax 0,5 4,5 6,5 5,0 1,5 -3,0 -10,0 1/3 Qmax -12,0 Model VERTICAL DISCHARGE 8000 Frequency bands in Hz Outlet Inlet -1,5 2,5 4,5 3,0 -0,5 -5,0 Qmax 4,5 9,0 10,5 8,5 6,5 5,5 3,0 2/3 Qmax 3,0 5,0 6,0 4,5 1,0 -3,0 -9,5 1/3 Qmax 1,0 3,0 4,0 2,5 -1,0 -5,0 -11,5 Sound power spectrum The sound pressure spectrum, at a distance “d”, can be obtained by subtracting from each frequency band of the power spectrum, the correction value shown in the following chart: Distance (d) Correction (dB) 1m 1,5m 4m 6m 10m 15m 20m 30m 11,00 14,50 23,00 26,00 31,00 34,00 37,00 40,00 Dimensions (mm) Fan model Ø AH BH 4 holes ØF ØD E C Ø AV Ø AH Ø AV BH BV oC Ø D* oE 140 415 421 277 359 300 180 245 ØF 10 180 415 421 292 374 300 180 245 10 200 561 556 340 404 435 250 330 12 225 561 570 383 452 435 250 330 12 250 762 750 425 522 560 355 450 12 315 762 750 469 564 560 355 450 12 400 850 850 532 608 630 400 535 12 450 962 950 713 741 710 500 590 14 500 1214 1216 824 832 905 630 750 14 560 1214 1216 874 832 905 630 750 14 630 1336 1327 1029 1053 1100 710 840 14 710 1336 1485 1127 1161 1100 710 840 14 * Nominal accessories diameter. BV 4 holes ØF ØD E C www.solerpalau.com Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT 377 Centrifugal roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT Series Mounting accessories Model JMS-300 JMS-435 JMS-560 JMS-630 JMS-710 JMS-905 JMS-1100 A B C F JMS Sealing frame – For mounting a roof fan on an up stand or base. – Supplied with screws and gasket for a complete weatherproof seal. E j n A B 300 E G JPA Accessory adapter plate – Used when mounting the accessories (JCA, JBR, JAE). – Allows the fan to be disconnected from the upstand without having to remove the duct. JCA Backdraft shutter – Prevents backdraft when the fan is not operating. – To be mounted at the fan inlet with the JPA plate. ØD (M) C C ØD nx t H Ø J Ø H Ø D p q 378 ØJ ØH E JBR Flange – For use when circular connection is required directly to the fan. – To be mounted at the fan inlet with the JPA plate or fixed directly to the fan base (rivets or screws not supplied). ØD JAE Flexible coupling – Reduces the transmission of vibrations when the duct is connected directly to the fan. – To be mounted at the fan inlet with JPA plate. JCC Adapter for circular duct – For use when fitting the models up to 400, directly to a spirally wound circular duct. Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT £B £ C o oA oB Model JBS-300 470 289 JBS-435 600 419 JBS-560 725 544 JBS-630 795 614 JBS-710 875 694 JBS-905 1065 884 JBS-1100 1260 1079 Model JPA-300 JPA-435 JPA-560 JPA-630 JPA-710 JPA-905 JPA-1100 B F m JBS Flat roof up stand For mounting a fan on a flat roof without up stands. – For use on horizontal roofs. – Internal insulation to prevent condensation. – Supplied with screws and gasket for a complete weather seal. E k oA oB 470 290 600 420 725 545 795 615 875 695 1065 885 1260 1080 Model JCA-300 JCA-435 JCA-560-N JCA-630-N JCA-710-N JCA-905-N JCA-1100-N E 50 50 50 50 50 60 60 oC 245 330 450 535 590 750 840 oC Ø D (M) 245 10,5 (M8) 330 11 (M10) 450 11 (M10) 535 11 (M10) 590 16 (M14) 750 16 (M14) 840 16 (M14) F 70 70 70 70 70 70 70 E oG 300 380 300 510 300 635 300 705 300 785 400 975 400 1170 oB oC ØD 289 419 544 614 694 884 1079 245 330 450 535 590 750 840 182 4xM6 205 252 4xM8 280 358 8xM8 395 403 8xM10 450 503 12xM10 560 633 12xM10 690 713 16xM10 770 nxt ØH ØD E F ØH ØJ 182 252 358 403 503 633 713 100 145 210 240 285 345 390 124 174 227 250 300 365 410 205 280 395 450 560 690 770 219 300 415 474 581 714 806 Model JBR-300 N JBR-435 N JBR-560 N JBR-630 N JBR-710 N JBR-905 N JBR-1100 N ØD E ØH ØJ 182 252 358 403 503 633 713 55 55 55 63 69 69 69 205 280 395 450 560 690 770 219 300 415 474 581 714 797 Model JAE-300 N JAE-435 N JAE-560 N JAE-630 N JAE-710 N JAE-905 N JAE-1100 N ØD E ØH ØJ 182 252 358 403 503 633 713 254 254 254 254 254 254 254 205 280 395 450 560 690 770 219 300 415 474 581 714 797 Model JCC-300 JCC-435 JCC-560 JCC-630 ØB ØC ØD E L 290 390 520 605 245 330 450 535 180 250 355 400 45 60 70 70 350 350 350 350 www.solerpalau.com Centrifugal roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT Series Mounting accessories r BI Support base for inclined curb mounted installations – To ensure a proper installation of the MAXTEMP roof fan it is essential to specify the roof pitch angle and the distance between the roof beam profiles. Model BI-3 BI-4 BI-5 BI-6 BI-7 BI-9 BI-11 Viewed in A direction d: Distance between the roof beam profiles a: Roof pitch angle (curb) l JAA Acoustic up stand – Reduces in duct and radiated noise. – For use when mounting a fan on a flat roof without up stands. – Supplied with screws and gasket for a complete weather seal. oA oB Model JAA-300 470 290 JAA-435 600 419 JAA-560 725 545 JAA-630 795 615 JAA-710 875 695 JAA-905 1065 885 JAA-1100 1260 1080 oC 245 330 450 535 590 750 840 B 289 419 544 614 694 884 1079 C 245 330 450 535 590 750 840 Ø D (M) H oG 13 (MI0) 750 380 15 (MI2) 750 510 15 (MI2) 750 635 15 (MI2) 750 705 18 (MI4) 1000 785 18 (MI4) 1000 975 18 (MI4) 1000 1170 REVERSE MOUNTING STANDARD MOUNTING WITH ACCESSORIES Acoustic attenuation in dB(A) at the corresponding frequency band in Hz. 125 1 1 2 2 2 2 2 Model JAA-300 JAA-435 JAA-560 JAA-630 JAA-710 JAA-905 JAA-1100 JAA Attenuator pressure drops. 15 250 5 7 8 8 8 7 7 REVERSE MOUNTING WITH ACCESSORIES 500 13 16 16 14 14 14 16 1000 22 23 29 24 24 26 27 2000 23 25 32 27 28 30 32 4000 16 18 26 19 16 19 20 8000 12 13 17 13 11 12 13 mmWG 10 300 435 560 630 710 905 1100 5 500 www.solerpalau.com 1000 1500 2000 3000 4000 5000 10000 15000 Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT 20000 qv [m3/h] 379 Centrifugal roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT Series Installation ➃ ➀ or ➁ ➂ or or ➈ ➇ ➄ ➆ ➅ Fan model 140 180 200 225 250 315 400 450 500 560 630 710 j k l m n o p q r Sealing frame Flat roof insulated up stand Acoustic up stand Accessory adapter plate Back draft shutter Flange with spigot Flexible coupling Circular adapter Support base for inclined curb mounted installations JMS-300 JBS-300 JAA-300 JPA-300 JCA-300 JBR-300 N JAE-300 N JCC-300 BI-3 JMS-435 JBS-435 JAA-435 JPA-435 JCA-435 JBR-435 N JAE-435 N JCC-435 BI-4 JMS-560 JBS-560 JAA-560 JPA-560 JCA-560-N JBR-560 N JAE-560 N JCC-560 BI-5 JMS-630 JMS-710 JBS-630 JBS-710 JAA-630 JAA-710 JPA-630 JPA-710 JCA-630-N JCA-710-N JBR-630 N JBR-710 N JAE-630 N JAE-710 N JCC-630 – BI-6 BI-7 JMS-905 JBS-905 JAA-905 JPA-905 JCA-905-N JBR-905 N JAE-905 N – BI-9 JMS-1100 JBS-1100 JAA-1100 JPA-1100 JCA-1100-N JBR-1100 N JAE-1100 N – BI-11 Electrical accessories 380 REB Single phase electronic speed controllers. – For use with the single phase roof fans. REB-5 / REB-10 Single phase electronic speed controllers. – For use with the single phase roof fans phase roof fans. RMB / RMT Auto transformer speed controllers. – For single phase and three phase roof fans models from 140 to 400. On/ Off Electrical isolation switch – Switch On/ Off 5P (1 speed motor) – Switch On/ Off 8P (2 speed motor). COM D/S Switch – To connect three phase fans with 400 V motor. – For three phase roof fans models from 140 to 400. DEMA DH Switch for 2-speed motors with Dahlander. VFTM IP54 Adjustable frequency drives for three phase motors from 0,37 to 15 kW. VFKB IP65 Adjustable frequency drive for three phase motors from 0,37 to 4 kW. Roof mounted fans MAX-TEMP CTHB/CTHT - CTVB/CTVT www.solerpalau.com Centrifugal roof mounted fans CTVT HP Series F400-120 CTVT Standard version Range of centrifugal roof mounted fans in vertical discharge format, designed for smoke extraction in fire conditions suitable for F400-120 application, base parts manufactured in galvanised sheet steel, cowls manufactured from spun aluminium, centrifugal backward curved impellers manufactured in double coated painted sheet steel (cataphoresis + polyester), discharge proof guard, and ON-OFF electrical isolator switch incorporated. Acoustic version (INS) with silencer integrated at the fan discharge, to reduce outlet noise level. All model suitable for air stream temperature up to 120ºC continuous. Motors 4 pole motors, three phase 400V-50Hz, IP55, Class F with PTC. Speed controllable by frequency drive. The electrical installation must be equipped with a security system which allows the maximum speed of the fans in case of fire and disconects PTC. On request 4/8 and 4/6 pole motors. Specific applications F400-120 Approved to EN12101-3 standard Certificate nº 0370-CPD-0347 CTVT INS Acoustic version TECHNICAL CHARACTERISTICS Model type Speed (rpm) Maximum absorbed power (kW) Maximum absorbed current 400V (A) Maximum airflow (m3/h) SPL* (dB(A)) Outlet Weight (kg) Standard version CTVT/4-632 5,5KW 1465 6,10 10,9 18.000 83 177 CTVT/4-631 7,5KW 1480 6,67 12,4 20.700 85 180 CTVT/4-712 11KW 1470 12,25 21,3 26.000 90 267 CTVT/4-711 15KW 1480 16,39 29,5 32.500 90 303 CTVT/4-802 18,5KW 1480 19,85 34,5 35.400 91 361 CTVT/4-801 22KW 1485 26,00 43,6 44.500 94 376 Acoustic version (INS) CTVT/4-632 5,5KW INS 1465 6,10 10,9 18.000 70 221 CTVT/4-631 7,5KW INS 1480 6,67 12,4 20.700 77 224 CTVT/4-712 11KW INS 1470 12,25 21,3 26.000 82 357 CTVT/4-711 15KW INS 1480 16,39 29,5 32.500 83 393 CTVT/4-802 18,5KW INS 1480 19,85 34,5 35.400 83 492 CTVT/4-801 22KW INS 1485 26,00 43,6 44.500 87 507 * Max. sound pressure level measured at 3m, in hemispherical radiation. www.solerpalau.com Roof mounted fans CTVT HP Centrifugal roof mounted fans CTVT HP Series PERFORMANCE CURVES - ACOUSTIC CHARACTERISTICS –qv: Airflow in m3/h. –psf: Static pressure in Pa. –P: Input power in W. –Sound pressure level @ 3 m, hemispherical radiation, in dB(A). –Performance data in accordance with ISO 5801. CTVT/4-632 5,55,5kW kW CTV T/4-632 CTVT/4-631 kW CTV T/4-6317,57,5kW psf psf [Pa] [Pa] 50H 1000 50 Hz 1000 z 80 81 800 800 40H 40 Hz z 600 75 600 81 76 83 400 30Hz 76 69 25Hz 70 70 P [W] 6000 68 0 4000 66 200 66 8000 72 0 12000 72 68 83 79 0 16000 qv [m3/h] 50Hz P [W] 6000 0 4000 8000 40Hz 2000 30Hz 30Hz 25Hz 0 0 4000 8000 12000 16000 qv [m 3 /h] Sound power spectrum: Standard version sound power spectrum LwA, at the fan outlet. OUTPUT 30Hz 25Hz qv [m3/h] 50Hz 25Hz 40Hz 12000 16000 20000 40Hz 2000 50Hz 85 80 74 70 4000 4000 0 78 25 Hz 65 200 3 0 Hz 400 63 125 250 500 1000 2000 4000 8000 STD* INS* LP 78 85 96 93 93 95 87 77 101 87 MP 74 84 95 90 90 90 82 73 98 88 HP 75 83 94 90 90 89 81 75 98 87 LP 73 80 91 88 88 90 83 72 96 83 MP 69 79 90 86 85 85 77 68 93 83 HP 70 78 89 85 85 84 76 70 93 83 LP 67 74 85 82 82 84 76 66 90 76 MP 63 73 84 79 79 78 71 62 87 76 HP 64 72 83 79 79 78 70 63 87 76 LP 63 70 81 78 78 80 72 62 86 72 MP 59 69 80 75 75 74 67 58 83 73 HP 60 68 79 75 75 74 66 59 83 72 * STD: Standard version - INS: Acoustic version Roof mounted fans CTVT HP 0 4000 8000 12000 16000 20000 qv [m3/h] Sound power spectrum: Standard version sound power spectrum LwA, at the fan outlet. OUTPUT 50Hz 40Hz 30Hz 25Hz 63 125 250 500 1000 2000 4000 8000 STD* INS* LP 71 79 95 93 94 99 93 83 103 94 MP 69 79 95 92 94 94 86 81 100 96 HP 68 78 95 90 92 89 82 79 98 98 LP 66 74 90 88 89 94 88 78 98 90 MP 64 74 90 87 89 89 81 76 95 91 HP 63 73 90 85 87 84 77 74 93 93 LP 60 68 84 82 83 88 82 72 92 83 MP 58 68 84 81 83 83 75 70 89 85 HP 57 67 84 79 81 78 71 68 87 87 LP 56 64 80 78 79 84 78 68 88 79 MP 54 64 80 77 79 79 71 66 85 81 HP 53 63 80 75 77 74 67 64 83 83 * STD: Standard version - INS: Acoustic version www.solerpalau.com Centrifugal roof mounted fans CTVT HP Series PERFORMANCE CURVES - ACOUSTIC CHARACTERISTICS –qv: Airflow in m3/h. –psf: Static pressure in Pa. –P: Input power in W. –Sound pressure level @ 3 m, hemispherical radiation, in dB(A). –Performance data in accordance with ISO 5801. CTV T/4-711 15kW CTVT/4-711 15kW CTV T/4-71211kW 11kW CTVT/4-712 psf psf [Pa] [Pa] 1400 50Hz 1400 5 0Hz 82 81 1200 1200 1000 1000 40Hz 76 800 600 85 85 600 30Hz 70 400 25Hz 66 0 P [W] 400 74 200 10000 15000 20000 25000 qv[m3/h] 50Hz 0 10000 20000 30000 qv[m3/h] 50Hz 25Hz 0 5000 OUTPUT 10000 15000 20000 25000 63 125 500 1000 2000 4000 8000 STD* INS* LP 78 90 97 100 102 102 97 88 107 100 MP 74 86 93 96 98 94 88 80 102 94 HP 73 87 90 93 94 89 83 75 98 89 LP 73 85 92 95 97 97 93 83 102 95 MP 69 81 88 91 94 89 84 75 97 89 HP 68 83 85 88 89 84 79 71 94 85 LP 67 79 86 88 91 91 86 77 96 89 MP 63 74 81 85 87 83 77 69 91 83 HP 62 76 79 82 83 78 72 64 87 78 LP 63 75 82 85 87 87 82 73 92 85 MP 59 70 77 81 83 79 73 65 87 79 HP 58 72 75 78 79 74 68 60 83 74 www.solerpalau.com 0 qv[m3/h] 250 * STD: Standard version - INS: Acoustic version 40Hz 30Hz 4000 30Hz Sound power spectrum: Standard version sound power spectrum LwA, at the fan outlet. 25Hz P [W] 8000 40Hz 3000 30Hz 0 79 12000 6000 40Hz 85 75 16000 9000 50Hz 90 70 79 12000 0 67 200 85 75 5000 25Hz 80 71 74 90 70 0 77 800 80 30Hz 40Hz 25Hz 0 10000 20000 30000 qv[m3/h] Sound power spectrum: Standard version sound power spectrum LwA, at the fan outlet. OUTPUT 50Hz 40Hz 30Hz 25Hz 63 125 250 500 1000 2000 4000 8000 STD* INS* LP 78 88 100 101 101 101 98 89 107 100 MP 73 88 97 96 96 91 93 81 102 94 HP 69 86 95 93 93 88 89 77 100 91 LP 74 84 95 96 96 96 94 84 102 95 MP 69 83 92 91 92 87 88 76 98 89 HP 65 81 90 88 89 84 84 72 95 86 LP 67 77 89 90 90 90 87 78 96 89 MP 62 77 86 85 85 80 82 70 91 83 HP 58 75 84 82 82 77 78 66 89 80 LP 63 73 85 86 86 86 83 74 92 85 MP 58 73 82 81 81 76 78 66 87 79 HP 54 71 80 78 78 73 74 62 85 76 * STD: Standard version - INS: Acoustic version Roof mounted fans CTVT HP Centrifugal roof mounted fans CTVT HP Series PERFORMANCE CURVES - ACOUSTIC CHARACTERISTICS –qv: Airflow in m3/h. –psf: Static pressure in Pa. –P: Input power in W. –Sound pressure level @ 3 m, hemispherical radiation, in dB(A). –Performance data in accordance with ISO 5801. CTV T/4-801 22kW CTVT/4-801 22kW CTV T/4-80218,5kW 18,5kW CTVT/4-802 psf [Pa] psf 50Hz [Pa] 50Hz 1600 1600 82 1400 1400 1200 1200 87 40 Hz 40Hz 1000 78 1000 86 800 30Hz 400 25Hz 67 76 10000 20000 200 30000 qv[m 3 0 /h] P [W] 25000 16000 20000 12000 15000 8000 10000 4000 5000 0 0 10000 20000 30000 qv[m3/h] Sound power spectrum: Standard version sound power spectrum LwA, at the fan outlet. OUTPUT 50Hz 40Hz 30Hz 25Hz 63 125 80 250 500 1000 2000 4000 8000 STD* INS* LP 79 90 97 101 102 103 99 90 108 101 MP 75 86 93 99 98 96 91 82 103 97 HP 74 87 90 96 94 91 86 79 100 94 LP 74 86 92 97 97 99 95 85 103 96 MP 70 82 89 94 93 91 86 77 99 92 HP 69 82 86 91 89 87 82 74 95 90 LP 68 79 85 90 91 92 88 79 97 90 MP 64 75 82 88 87 85 80 71 92 86 HP 63 76 79 85 83 80 75 68 89 89 LP 64 75 82 86 87 88 84 75 93 86 MP 60 71 78 84 83 81 76 67 88 82 HP 59 72 75 81 79 76 71 64 85 79 * STD: Standard version - INS: Acoustic version Roof mounted fans CTVT HP 94 76 80 20000 0 72 91 86 86 76 25 Hz 400 75 71 0 30 Hz 600 81 71 200 P [W] 91 800 600 0 82 89 79 0 10000 20000 83 30000 40000 qv[m3/h] 50Hz 40Hz 30Hz 25Hz 0 10000 20000 30000 40000 qv[m3/h] Sound power spectrum: Standard version sound power spectrum LwA, at the fan outlet. OUTPUT 50Hz 40Hz 30Hz 25Hz 63 125 250 500 1000 2000 4000 8000 STD* INS* LP 80 93 101 104 108 103 101 89 112 104 MP 79 90 98 101 106 100 94 85 108 102 HP 76 89 93 98 102 94 86 81 104 98 LP 76 88 96 99 104 98 96 84 107 99 MP 74 85 93 96 101 95 89 80 104 97 HP 71 84 88 93 97 90 82 76 99 93 LP 69 82 90 92 97 92 90 78 100 93 MP 68 79 87 90 95 89 83 74 97 91 HP 65 78 82 87 90 83 75 70 93 87 LP 65 78 86 88 93 88 86 74 96 89 MP 64 75 83 86 91 85 79 70 93 87 HP 61 74 78 83 87 79 71 66 89 83 * STD: Standard version - INS: Acoustic version www.solerpalau.com Centrifugal roof mounted fans CTVT HP Series DIMENSIONS (mm) CTVT Standard version Ø AV Model AV BV C E CTVT/4-632 5,5KW 1216 930 905 750 CTVT/4-631 7,5KW 1216 930 905 750 CTVT/4-712 11KW 1485 1146 1270 950 CTVT/4-711 15KW 1485 1188 1270 950 1485 1207 1270 950 1485 1225 1270 950 BV C E BV CTVT/4-802 18,5KW CTVT/4-801 22KW 4 Ø 14 E C CTVT INS Acoustic version Ø AV Model AV CTVT/4-632 5,5KW INS 1342 978 905 750 CTVT/4-631 7,5KW INS 1342 978 905 750 CTVT/4-712 11KW INS 1611 1163 1270 950 CTVT/4-711 15KW INS 1611 1250 1270 950 1611 1274 1270 950 CTVT/4-801 22KW INS 1611 1292 1270 950 BV CTVT/4-802 18,5KW INS 4 Ø 14 E C www.solerpalau.com Roof mounted fans CTVT HP Centrifugal roof mounted fans CTVT HP Series Mounting accessories JPA Accessory adapter plate – Used when mounting the accessories (JCA, JBR, JAE). – Allows the fan to be disconnected from the upstand without having to remove the duct. JCA N Backdraft shutter – Prevents backdraft when the fan is not operating. – To be mounted at the fan inlet with the JPA plate. A B C E F JMS-905 1065 885 750 60 70 JMS-1250 1410 1230 950 60 70 F E C A B Ø D (M) E Model A B JBS-905 1065 884 750 16 (M10) 400 C G 975 JBS-V-1000 1447 1247 950 18 (M12) 400 1347 E ØD (M) C G Model B C ØD nxt B JPA-905 884 750 633 12xM10 ØH 690 C JPA-1250 1230 950 1000 8xM12 1070 ØJ ØD nx t H Ø J Ø H F JBS/JBS-V Flat roof up stand – For mounting a fan on a flat roofwithout up stands. – For use on horizontal roofs. – Internal insulation to prevent condensation. – Supplied with screws and gasket for a complete weather seal. A B Model Model ØD E F ØH JCA-905 N 633 345 365 690 714 JCA-1250 N 1004 560 560 1070 1110 E JMS Sealing frame – For mounting a roof fan on an up stand or base. – Supplied with screws and gasket for a complete weatherproof seal. Ø D JAE N Flexible coupling – Reduces the transmission of vibrations when the duct is connected directly to the fan. – To be mounted at the fan inlet with JPA plate. Roof mounted fans CTVT HP Model ØD E ØH ØJ JBR-905 N 633 55 690 ØJ 714 ØH JBR-1250 N 1004 60 1070 1110 Model ØD E ØH ØJ JAE-905 N 633 164 690 714 JAE-1250 N 1004 185 1070 1110 E JBR N Flange – For use when circular connection is required directly to the fan. – To be mounted at the fan inlet with the JPA plate or fixed directly to the fan base (rivets or screws not supplied). ØD www.solerpalau.com Centrifugal roof mounted fans CTVT HP Series Mounting accessories - INSTALLATION 3 1 or 2 4 6 5 Fan model CTVT/4-632 CTVT/4-631 1 Sealing frame 2 Flat roof insulated up stand 3 Accessory adapter plate 4 Back draft shutter 5 Flange with spigot 6 Flexible coupling JMS-905 JBS-905 JPA-905 JCA-905 N JBR-905 N JAE-905 N JMS-1250 JBS-V-1000 JPA-1250 JCA-1250 N JBR-1250 N JAE-1250 N CTVT/4-712 CTVT/4-711 CTVT/4-802 CTVT/4-801 www.solerpalau.com Roof mounted fans CTVT HP
Similar documents
details
Technical characteristics for models with horizontal discharge CTHB/ CTHT Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequ...
More informationNSPT-LOCKS
B NSPT-LOCKS is a commonly used standard type locks. If this type lock is used, the machining precision of the joint components can be reduced since over-consideration of the interference and preci...
More informationworkholding specialists - Mitee-Bite
of two simple components: a hardened steel socket cap screw with an offset head and a brass hexagonal washer. Low-profile for quick and easy installation of linear motion guide rails Cam action p...
More information