Meter Sockets
Transcription
Meter Sockets
Meter Sockets Table of Contents 20 A 600 V – CL, CT, CT-SWL Series .............................................. D3–D5 100 A 600 V – R3, BA3 Series ........................................................ D6–D7 100 A 600 V King Size – BE1 Series .......................................................D8 100 A per Position 200 A 600 V – BE2, BEC Series ....................... D9–D10 100 A 600 V Polyphase – PL17 Series ................................................. D11 100 A 120/240 V – CO1 Series ............................................................ D12 100 A per Position 120/240 V – CO1 Multi-Gang .................................. D13 100 A 120/240 V – HD Series ............................................................... D14 200 A 600 V – BQ, BP, BS2, BS4M-V, MO2 Series ...................... D15–D25 200 A per Position 200 A 600 V – BD, BDA, BDC, BS4 Series .....D26–D29 200 A per Position 400 A 600 V – BSC4-G Series ..............................D30 200 A 600 V Polyphase – PL27 Series .................................................D31 200 A 120/240 V – CO2 Series ................................................... D32–D33 200 A 120/240 V – CO22, CO23, CO24 Series .....................................D34 200 A 120/240 V – CO22-U, CO23-U, CO24-U Series .........................D35 400 A 120/240 V – CO42 Series ...........................................................D36 200 A 120/208 V – CO27 Series ..........................................................D37 320 A 600 V – BP320 Series ...............................................................D38 400 A 600 V – FA4B-6T .......................................................................D39 400 A 120/240 V – JS4 Series ................................................... D40–D41 Typical Wiring Diagrams .............................................................. D42–D43 Accessories .................................................................................D44–D48 Meter Covers ........................................................................................D49 Service Masts.............................................................................. D50–D59 Pole Line Hardware .....................................................................D60–D69 Carlon® Nonmetallic Conduits ...................................................... D70–D72 Carlon® PV-Mold™ ....................................................................... D73–D77 E-Z-Ground® Grounding Systems ................................................. D78–D85 E-Z-Ground® Types of Connectors ........................................................D86 w w w. t n b. c a D1 Meter Sockets D2 w w w. t n b. c a Meter Sockets CL Series 20 A 600 V; Transformer Rated Product Specifications • • • • • • • Conductor range: 14-10 AWG Aluminum tunnel type connectors for both load and line sides Circuit closing feature to short out current transformer upon removal of meter For overhead hub opening only Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in: Sask., Man., Ont., N.B., N.S., P.E.I., Nfld. (CL4-V) 3-11/16 in. Trade Size Knockout 1-1/4 and 1-1/2 in. 1 Place Trade Size Knockout 1/2, 1 and 1-1/4 in. 2 Places 4-5/8 in. Trade Size Knockout 3/4, 1 and 1-1/4 in. 3 Places 9-1/4 in. 1-3/8 in. 1-1/2 in. 1/2 in. 1-3/4 in. 2-9/16 in. Trade Size Knockout 1/4 in. 1 Place 1-9/16 in. Approved for copper only Cat. No. 4 JAW CL4-V CL4-LRV CL4-TV 5 JAW CL5-V 6 JAW CL6-LRV w w w. t n b. c a H Dimensions (in.) W D 9-1/4 7-5/8 3-11/16 7 3.1 Circuit closing on left side (Lower right hand jaw is a support only) 9-1/4 7-5/8 3-11/16 7 3.1 Circuit closing both left and right sides 9-1/4 7-5/8 3-11/16 7 3.1 Description Weight Each lb. kg Circuit closing on left side Circuit closing both left and right sides Circuit closing on left side, no hub opening D3 Meter Sockets CT Series 20 A 600 V; Transformer Rated c/w Compartment for Test Switch Product Specifications • Conductor range: 14-10 AWG • Tunnel type connectors for both load and line sides • For underground service only • Meter compartment cover overlaps lower test switch compartment cover; insertion of meter securely holds upper cover in place by means of a catch • Lower test switch compartment cover securely held by upper cover and a catch at bottom 19-1/8 in. • A removable mounting bridge is provided for fastening test switch • Supplied with screw type ring • Primarily used in: AB, Sask., Man., Ont., N.B., N.S., P.E.I. (CT113) Trade Size Knockout 3/4, 1 and 1-1/4 in. 3 Places 5-7/16 in. 3/8 in. 1-5/16 in. 3-5/8 in. 13/16 in. Trade Size Knockout 1/2 in. 1 Place 7-7/8 in. 1-3/4 in. Trade Size Knockout 1/2 in. 1 Place 1-15/16 in. 1-7/16 in. Trade Size Knockout 3/4, 1 and 1-1/4 in. 3 Places 1-1/2 in. Approved for copper only H Dimensions (in.) W D Unwired unit with test switch provision 19-1/8 11-13/16 5-7/16 16 7.2 Unwired unit with test switch provision 19-1/8 11-13/16 5-7/16 16 7.2 Unwired unit with test switch provision 19-1/8 11-13/16 5-7/16 18 8.1 Unwired unit with test switch provision 19-1/8 11-13/16 5-7/16 19 8.6 Cat. No. 4 JAW CT104 5 JAW CT105 8 JAW CT108 13 JAW CT113 Description Lower test switch compartment cover securely held by upper cover and a out device with an enlarged pad hole (0.375 in. dia.) Cat. No. 5 JAW CT105-L 8 JAW CT108-L 13 JAW CT113-L D4 Description Weight Each lb. kg Approved for copper only H Dimensions (in.) W D Weight Each lb. kg BC Hydro approved with SWL cover with enlarged padlock hole 19-1/8 11-13/16 5-7/16 16 7.2 BC Hydro approved with SWL cover with enlarged padlock hole 19-1/8 11-13/16 5-7/16 18 8.1 BC Hydro approved with SWL cover with enlarged padlock hole 19-1/8 11-13/16 5-7/16 19 8.6 w w w. t n b. c a Meter Sockets CT-SWL Series 20 A 600 V; Transformer Rated c/w Test Switch Product Specifications •Conductor range: 14-10 AWG •Tunnel type connectors for both load and line sides •For underground service only •Lower test switch compartment cover securely held by upper cover and a out device with an enlarged pad hole (0.375 in. dia.) •Test switch included as part of these models •Units are prewired from base to test switch •Furnished with tamper resistant device for meter ring •Weatherproof Type 3R enclosure •Primarily used in: Alberta (CT104-5SWLHQ for Hydro-Québec only) Trade Size Knockout 3/4, 1 and 1-1/4 in. 3 Places (CT104-SWL) 5-7/16 in. 19-1/8 in. 3/8 in. 1-5/16 in. 3-5/8 in. 13/16 in. Trade Size Knockout 1/2 in. 1 Place 1-5/16 in. 7-7/8 in. 1-7/16 in. Trade Size Knockout 1/2 in. 1 Place 1-3/4 in. Trade Size Knockout 1/2, 3/4, 1 and 1-1/4 in. 3 Places Cat. No. 4 JAW CT104-SWL CT104-6SWL CT104-5SWLHQ 5 JAW CT105-SLHO 6 JAW CT106-SWL 13 JAW CT113-SWL w w w. t nb. c a Approved for copper only 1-1/2 in. H Dimensions (in.) W D 19-1/8 11-13/16 5-7/16 18 8.2 18 8-1/4 4-1/2 11 5.4 Hydro One approved 20 A current transformer meter socket 19-1/8 11-13/16 5-7/16 18 8.2 Factory prewired unit with lockout device on bottom door 19-1/8 11-13/16 5-7/16 21 9.5 Factory prewired unit with lockout device on bottom door 19-1/8 11-13/16 5-7/16 21 9.5 Description Factory prewired unit with lockout device on bottom door Factory prewired unit with lockout device on bottom door (Enmax approved) 5th Jaw in 6 o’clock position Hydro-Québec approved 20 A current transformer meter socket Weight Each lb. kg D5 Meter Sockets R3 Series 100 A 600 V; Round Aluminum Product Specifications •Conductor range: 14-2 AWG •Aluminum tunnel type connectors for both load and line sides •Can be converted from vertical to horizontal mounting using same components •Supplied with screw type ring •Aluminum die cast socket •Weatherproof Type 3R enclosure •Primarily used in: B.C., Northern Ont. (R3-1V) 2-7/8 in. 1-1/8 in. 2-1/8 in. 2-7/8 in. 5-1/8 in. 7-1/8 in. Approved for copper only Cat. No. 4 JAW R3-1V R3-1-1/4V R3-1-5V R3-1 1/4-5V D6 Description 1 in. hub 1-1/4 in. hub 1 in. hub - 5th jaw, standard capacity, 9 o’clock position 1-1/4 in. hub - 5th jaw, standard capacity, 9 o’clock position Dimensions (in.) Dia. 7-1/8 D 3-1/8 Weight Each lb. kg 2 0.9 w w w.t nb.c a Meter Sockets BA3 Series 100 A 600 V; Shallow Product Specifications • • • • • • Conductor range: 6-2 AWG Aluminum tunnel type connectors for both load and line sides For overhead, underground and combination overhead/underground Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in: All provinces Note: Supply from an underground network often requires use of stud type connector. Consult your local utility. (BA3-1 1/4V) 5 in. 1-9/16 in. Trade Size Knockout 1/2, 1 and 1-1/4 in. 2 Places 6-1/8 in. 9-1/4 in. Trade Size Knockout 1-1/4, 1 and 1-1/2 in. Trade Size Knockout 1/4 in. 1-7/16 in. 1-5/16 in. 7/16 in. 1-7/16 in. 1-7/16 in. 7-7/16 in. 2-9/16 in. Approved for copper only Cat. No. Description 4 JAW Overhead, hub opening BA3-V Overhead, hub opening, c/w 1 in. hub BA3-1V Overhead, hub opening, c/w 1-1/4 in. hub BA3-1 1/4V Underground BA3-TV Combination overhead-underground BA3-TCV Overhead, twin hub opening BA33-V Overhead, twin hub opening c/w 1 in. hubs BA33-1V Overhead, twin hub opening, c/w 1-1/4 in. hubs BA33-1 1/4V Indoor type, K.O. on top BA4-V FACTORY-INSTALLED ACCESSORIES Insulated Neutral Include: -IN 5th jaw, standard capacity, 9 o’clock position -5 5th jaw, full capacity, 9 o’clock position -9 w w w. t n b. c a H Dimensions (in.) W D 9-1/4 7-7/16 3-11/16 Weight Each lb. kg 5 2.2 D7 Meter Sockets BE1 Series 100 A 600 V; King Size Product Specifications • • • • • • Conductor range: 6-1/0 AWG Aluminum tunnel type connectors for both load and line sides For overhead, underground and combination overhead/underground Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in all provinces Note: Supply from an underground network often requires use of stud type connector. Consult your local utility. 4-3/8 in. Trade Size Knockout 1/4 in. (BE1-1 1/4V) Trade Size Knockout 1, 1-1/4, 1-1/2 and 2 in. 2 Places Trade Size Knockout 1/2 in. Trade Size Knockout 1/2 in. Trade Size Knockout 1/4 in. 3/4 in. 14-5/8 in. 1-13/16 in. 3/4 in. 3-3/8 in. 1-1/4 in. 3 in. Trade Size Knockout 1-1/4, 1-1/2 and 2 in. 1-13/16 in. OVERHEAD BOTTOM 2 in. 2-1/16 in. 1-7/16 in. 4 in. Trade Size Knockout 1-1/4, 1-1/2 and 2 in. COMBINATION AND UNDER GROUND BOTTOM Cat. No. Description 4 JAW Overhead, hub opening BE1-V Overhead, hub opening, c/w 1-1/4 in. hub BE1-1 1/4V Overhead, hub opening, c/w 1-1/2 in. hub BE1-1 1/2V Underground BE1-TV Combination overhead-underground BE1-TCV Overhead, twin hub opening BE11-V-CM Overhead, twin hub opening c/w 1-1/4 in. hubs BE11-1 1/4V FACTORY-INSTALLED ACCESSORIES 5th jaw, standard capacity, 9 o’clock position Include: -5 5th jaw, full capacity, 9 o’clock position -9 5th jaw, full capacity, 6 o’clock position -6 Insulated neutral -IN Water heater lugs -W D8 1-13/16 in. Approved for copper or aluminum Dimensions (in.) Weight Each H W D lb. kg 14-5/8 8-1/4 4-3/8 8 3.6 w w w. t n b. c a Meter Sockets BE2 Series 200 A (Main Lugs) 600 V; Multiple Position – Horizontal 100 A per Position Product Specifications (BE6-V) • • • • NOTE: Supply from an underground network often requires use of stud type connector. Consult your local utility. 5-3/16 in. • • • • Trade Size Knockout 1-1/4, 1-1/2 and 2 in. Trade Size Knockout 1/2 2 Places 14-5/8 in. Conductor range: Line: 6 AWG-250 kcmil, Load: 6-1/0 AWG Aluminum tunnel type connectors for both line and load sides Factory prebussed from main lugs to each position Combination overhead-underground supplied with hub opening closure plate for underground service Hubs to be ordered separately (refer to pp. D39 and D40) Supplied with screw type rings Weatherproof Type 3R enclosure Primarily used in: All provinces Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. (each side of the box separation) (for every box separation) 8-5/16 in. 8-3/16 in. (for each end of the bottom) 2-3/16 in. 1-13/16 in. 1-1/16 in. 1-1/16 in. 4-1/8 in. 4-1/16 in. 8-5/16 in. 8-5/16 in. 2-1/2 in. 2-1/4 in. Approved for copper or aluminum Cat. No. 4 JAW LEFT-HAND ENTRY RIGHT-HAND ENTRY BE2-V BE2-VH BE3-V BE3-VH BE4-V BE4-VH BE5-V BE5-VH BE6-V BE6-VH FACTORY-INSTALLED ACCESSORIES Include: -5 w w w. t n b. c a Meter Position 2 position 3 position 4 position 5 position 6 position H 14-5/8 Dimensions (in.) W 16-1/2 24-13/16 33-1/8 41-7/16 49-3/4 D 5-3/16 Weight Each lb. kg 18 26 34 42 50 8.1 11.8 15.4 19.0 22.7 5th jaw, standard capacity, 9 o’clock position D9 Meter Sockets BEC Series 200 A (Main Lugs) 600 V; Multiple Position – 100 A per Position Stud Type Product Specifications •Conductor range: Line: 1/2 in. studs supplied, Load: 6-1/0 AWG •Aluminum tunnel type connectors load side; stud 1/2 in. line side •For underground service only • Factory prebussed from main lugs to each position • Supplied with screw type rings • Weatherproof Type 3R enclosure •Primarily used in: B.C., *Sask. (extended enclosure), Man., Ont., Que. (BEC2-V) *N ote: Models with suffix -VA and -VAH = tunnel type connectors on line side provided instead of studs (required by B.C. Hydro). Conductor range: Line: 1–1/0 AWG, Load: 6–1/0 AWG. Cross Reference Underground meter required by BC Hydro Standard Step 8-5/16 in. 16-1/2 in. Required by BC Hydro Not accepted by BC Hydro for underground for underground applications application 15-1/8 in. 1/16 in. 4 in. Step 8-5/16 in. 12-5/16 in. PATTERN FOR BOTTOM 2-1/2 in. Trade Size Knockout 1/2 in. 2 Places Trade Size Knockout 1-1/2, 2, 2-1/2 and 3 in. 1 Place Trade Size Knockout 1-1/4, 1-1/2 and 2 in. Typical Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. Typical BE2-V BE3-V BE4-V BEC2-VH BEC3-VH BEC4-VH BEC2-V BEC3-V BEC4-V BEC2-VH BEC3-VH BEC4-VH BEC2-VA BEC3-VA BEC4-VA BEC2-VAH BEC3-VAH BEC4-VAH BEC2-VA BEC3-VA BEC4-VA BEC2-VAH BEC3-VAH BEC4-VAH 2-1/8 in. 5 in. 2-1/16 in. 2-3/8 in. 1-1/16 in. 1-7/8 in. 2-1/16 in. 1-1/16 in. 1-1/4 in. 1-1/16 in. 4 in. Cat. No. 4-1/8 in. Meter Position 4 JAW LEFT-HAND ENTRY RIGHT-HAND ENTRY 2 position BEC2-V BEC2-VH 2 position c/w connector (tunnel type) BEC2-VA* BEC2-VAH 2 position extended enclosure BEC2-VE* BEC2-VEH 3 position BEC3-V BEC3-VH 3 position c/w connector (tunnel type) BEC3-VA* BEC3-VAH 3 position extended enclosure BEC3-VE* – 4 position BEC4-V BEC4-VH 4 position c/w connector (tunnel type) BEC4-VA* BEC4-VAH 4 position extended enclosure BEC4-VE* – 5 position BEC5-V BEC5-VH 6 position BEC6-V BEC6-VH FACTORY INSTALLED ACCESSORIES 5th jaw, standard capacity, 9 o’clock position Include: -5 D10 4-3/16 in. Approved for copper or aluminum 4-3/16 in. H 15-1/8 Dimensions (in.) W D 24-3/16 Weight Each lb. kg 27 12.2 35 15.9 41-7/16 43 19.5 49-3/8 57-5/8 51 59 23.1 26.8 20-1/16 15-1/8 33-1/8 20-1/16 15-1/8 5 20-1/16 15-1/8 w w w.t nb.c a Meter Sockets PL17 Series 100 A 600 V; Polyphase Product Specifications • • • • • • Conductor range: 6-1/0 AWG Aluminum tunnel type connectors for both load and line sides For overhead, underground and combination overhead/underground Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in: All provinces 5-7/16 in. (PL17-INV) Trade Size Knockout 1-1/4, 1-1/2 and 2 in. Typical Trade Size Knockout 1/2 in. Trade Size Knockout 1/4 in. 15-5/8 in. Trade Size Knockout 1/2 in. Trade Size Knockout 1/4 in. 1-11/16 in. 9/16 in. 7/8 in. 1-11/16 in. 11/16 in. 1/2 in. 4 in. 1/2 in. 2-1/8 in. 13/16 in. 1-1/16 in. OVERHEAD BOTTOM COMBINATION AND UNDERGROUND BOTTOM 1-3/16 in. Approved for copper or aluminum Cat. No. Description 7 JAW Overhead, hub opening PL17-INV Overhead, hub opening (Hydro-Québec approved) PL17-INV-HQ Underground (Hydro-Québec spec) PL17-INTV-HQ Combination overhead-underground PL17-INTCV Combination overhead-underground (Hydro-Québec approved) PL17-INTCV-HQ Overhead, hub opening PL17-V Underground PL17-TV Combination overhead-underground PL17-TCV 8 JAW Overhead, hub opening PL17-8V Combination overhead-underground PL17-8TCV FACTORY INSTALLED ACCESSORIES Insulated neutral Include: -IN w w w. t n b. c a H Dimensions (in.) W D Weight Each lb. kg 15-5/8 8-9/16 5-7/16 12 5.4 15-5/8 8-9/16 5-7/16 12 5.4 D11 Meter Sockets CO1 Series 100 A 120/240 V; Combination with or without Breaker Product Specifications •Conductor range (Line and Load): 6-1/0 AWG •Aluminum tunnel type connectors for both load and line sides •For overhead installation •For underground installation, gutter option must be ordered (G) •With factory-installed neutral conductor •Suitable for 120/240 V single phase service entrance for mobile homes, trailers, temporary services, recreational parks and other commercial and residential locations •Bottom compartment has provision for 2 pole circuit breaker (max. 100 A) Siemens (Q), Square D (QO) •Supplied with screw type rings •Weatherproof Type 3R enclosure •Primarily used in: All provinces (CO1) 4-3/8 in. Trade Size Knockout 1-1/4, 1-1/2 and 2 in. 5 Places 5/16 in. 2 in. 4 in. Trade Size Knockout 1/2 in. 2 in. Trade Size Knockout 1/2 in. 1-13/16 in. Approved for copper or aluminum Cat. No. 4 JAW CO1 CO1-G CO1-5V CO1-60 CO1-70 CO1-100 CO1-100G CO1-100HI CO1-100HI-G CO1-SD CO1-SD-G Type Description Overhead Underground Overhead Overhead Overhead Overhead Underground Overhead Underground Overhead Underground Provision for Siemens (Q), 100 A 2 pole 10 kA rated circuit breaker Provision for Siemens (Q), 100 A 2 pole 10 kA rated circuit breaker, c/w gutter Provision for Siemens (Q), 100 A 2 pole 10 kA rated circuit breaker, c/w 5th jaw c/w Siemens Q260 60 A 2 pole 10 kA rated circuit breaker c/w Siemens Q270 70 A 2 pole 10 kA rated circuit breaker c/w Siemens Q2100 100 A 2 pole 10 kA rated circuit breaker c/w Siemens Q2100 100 A 2 pole 10 kA rated circuit breaker, c/w gutter c/w Siemens Q2100H 100 A 2 pole 22 kA rated circuit breaker c/w Siemens Q2100H 100 A 2 pole 22 kA rated circuit breaker, c/w gutter Provision for Square D type “QO” 70 A 2 pole 10 kA rated circuit breaker Provision for Square D type “QO” 100 A 2 pole 10 kA rated circuit breaker, c/w gutter H Dimensions (in.) W D 23-1/2 8-1/4 4-3/8 Weight Each lb. kg 15 6.8 Note: Some local utilities require a gutter option for underground services. Order with suffix -G. D12 w w w.t nb.c a Meter Sockets CO1 Multi-Gang 200 A (Main lugs), 100 A per position 120/240 V; Multi-Gang Combination with or without Breaker Product Specifications •Conductor range: Line: 6 AWG-250 kcmil, Load: 6-1/0 AWG •Overhead only – tunnel type connectors for both load and line sides •Underground only – aluminum tunnel type connector load side (6-1/0 AWG), line side 1/2 in. studs •Supplied with screw type rings •Weatherproof Type 3R enclosure •Bottom compartment has provision for 2 pole circuit breaker (max. 100 A) Siemens (Q), Square D (QO), Cutler (QR + BR) •Primarily used in: All provinces Quebec only: As per Hydro-Québec spec 23-1/2 in. (supplied with 22 kA Siemens breaker) 4-3/8 in. (CO12-100HI) Trade Size Knockout 1-1/4, 1-1/2 and 2 in. 4 Places Trade Size Knockout 1/2, 1-1/4, 1-1/2 and 2 in. 5 Places 15/16 in. 1-15/16 in. 8-5/16 in. 14-1/16 in. 1-15/16 in. Trade Size Knockout 1/2 in. 2 Places 2 in. 15/16 in. 4-1/8 in. Trade Size Knockout 1/2 in. 2 Places 4-1/8 in. 8-5/16 in. 8-5/16 in. 1-13/16 in. Approved for copper or aluminum Cat. No. 4 JAW CO12 CO12-100 CO12-100HI CO12-100HI-U CO12-SD CO12-SD-U CO13 CO13-100 CO13-100HI CO13-100HI-U CO13-SD CO13-SD-U CO14 CO14-100 CO14-100HI CO14-100HI-U CO14-SD CO14-SD-U Type Description Overhead Overhead Overhead Underground Overhead Underground Overhead Overhead Overhead Underground Overhead Underground Overhead Overhead Overhead Underground Overhead Underground 2 gang, provision for Siemens 2 x Q2100 100 A 2 pole 10 kA rated circuit breakers 2 gang, c/w Siemens 2 x Q2100 100 A 2 pole 10 kA rated circuit breakers 2 gang, c/w Siemens 2 x Q2100H 100 A 2 pole 22 kA rated circuit breakers 2 gang with blank compartment, c/w Siemens 2 x Q2100H 100 A 2 pole 22 kA rated circuit breakers 2 gang, provision for Square D type “QO” 2 x 100 A 2 pole 10 kA rated circuit breakers 2 gang with blank compartment, provision for Square D type “QO” 2 x 100 A 2 pole 10 kA rated circuit breakers 3 gang, provision for Siemens 3 x Q2100 100 A 2 pole 10 kA rated circuit breakers 3 gang, c/w Siemens 3 x Q2100 100 A 2 pole 10 kA rated circuit breakers 3 gang, c/w Siemens 3 x Q2100H 100 A 2 pole 22 kA rated circuit breakers 3 gang with blank compartment, c/w Siemens 3 x Q2100H 100 A 2 pole 22 kA rated circuit breakers 3 gang, provision for Square D type “QO” 3 x 100 A 2 pole 10 kA rated circuit breakers 3 gang with blank compartment, provision for Square D type “QO” 3 x 100 A 2 pole 10 kA rated circuit breakers 4 gang, provision for Siemens 4 x Q2100 100 A 2 pole 10 kA rated circuit breakers 4 gang, c/w Siemens 4 x Q2100 100 A 2 pole 10 kA rated circuit breakers 4 gang, c/w Siemens 4 x Q2100H 100 A 2 pole 22 kA rated circuit breakers 4 gang with blank compartment, c/w Siemens 4 x Q2100H 100 A 2 pole 22 kA rated circuit breakers 4 gang, provision for Square D type “QO” 4 x 100 A 2 pole 10 kA rated circuit breakers 4 gang with blank compartment, provision for Square D type “QO” 4 x 100 A 2 pole 10 kA rated circuit breakers Position Dimensions (in.) H W D 2 16-1/2 Weight Each lb. kg 30 13.60 45 20.41 60 27.21 24-3/4 3 23-1/2 4-3/8 33-1/8 33-1/8 4 41-7/16 Note: For underground version, add suffix -U. w w w. t nb. c a D13 Meter Sockets HD1 100 A 120/240 V; Flat Rate Services Junction Box Product Specifications • 100 A, 120/240 V single phase weatherproof junction box for flat rate services fed underground such as telephone booths, plastic signs, bus shelters, etc... • Aluminum tunnel type connector for line side • Bottom compartment has 2 in., 2-1/2 in., 3 in., 3-1/2 in. KO’s and 3/8 in. (load side) studs to accommodate compression lugs (supplied by utility) • Top compartment has provision for Thomas & Betts, Siemens, G.E., Westinghouse type “Q” 2 pole breaker • Weatherproof Type 3R enclosure • Primarily used in: Quebec only (HD1) Trade Size Knockout 2, 2-1/2, 3 and 3-1/2 in. 1 Place 2-5/8 in. 4-5/16 in. 8-5/8 in. Approved for copper and aluminum Cat. No. HD1 D14 Type Underground Dimensions (in.) Weight Each H W D lb. kg 23-1/2 8-5/8 6-1/16 20 9.0 w w w. t n b. c a Meter Sockets BQ2 Series 200 A 600 V; Standard Enclosure Product Specifications • • • • • • Conductor range: 6 AWG–250 kcmil Aluminum tunnel type connectors for both load and line sides For overhead, underground and combination overhead/underground Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in: All provinces Note: Supply from an underground network often requires use of stud type connector. Consult your local utility. 5-13/32 in. (BQ2-V) Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 2 Places Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 2 Places 29/64 in. 2-7/32 in. 2-1/4 in. 1-1/32 in. 7/8 in. K.O. 1/4 in. 4-3/8 in. 2-1/8 in. 3-17/64 in. COMBINATION AND UNDERGROUND BOTTOM K.O. 1/2 in. Trade size 3-3/4 in. OVERHEAD BOTTOM 1-13/16 in. 5-5/16 in. Cat. No Approved for copper and aluminum Description 4 JAW Overhead, hub opening BQ2-V Overhead, hub opening c/w 1-1/2 in. hub BQ2-1 1/2 V Overhead, hub opening c/w 2 in. hub BQ2-2V Underground BQ2-TV Combination, overhead-underground BQ2-TCV Overhead, twin hub opening BQ2-22VNH Overhead, twin hub opening c/w 2 in. hubs BQ2-22V Overhead, twin hub opening c/w 2 in. hub for B.C BQ2-2VR FACTORY INSTALLED ACCESSORIES Ground lug on neutral Include: -GN 5th jaw standard capacity -5 5th jaw full capacity, 6 o’clock position -6 w w w. t n b. c a H Dimensions (in.) W D 15-5/8 8-47/64 5-13/32 Weight Each lb. kg 12 5.4 D15 Meter Sockets BP2-TV 200 A 600 V; Standard Enclosure Product Specifications • • • • • • Conductor range: 6 AWG–250 kcmil Aluminum tunnel type connectors for both load and line sides For underground service only Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in: Ontario 5-7/16 in. (BP2-TV) Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 3 Sets Trade Size Knockout 1/2 in. Trade Size Knockout 1/4 in. 7/16 in. 2-3/16 in. 1-7/8 in. 13/16 in. 3-13/16 in. 3-13/16 in. 2-11/16 in. 12 in. 2-3/8 in. Approved for copper or aluminum Cat. No. BP2-TV D16 Description Underground H Dimensions (in.) W D 20 12 5-7/16 Weight Each lb. kg 16.5 7.48 w w w. t n b. c a Meter Sockets BS2 Series 200 A 600 V; Oversize Enclosure Product Specifications • • • • • • • Conductor range: 6 AWG-250 kcmil Aluminum tunnel type connectors for both load and line sides For overhead, underground and combination overhead/underground Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in: B.C., AB, Sask., Man., Ont., N.S. * May be use in all regions NOTE: Supply from an underground network often requires use of stud type connector. Consult your local utility. 5-7/16 in. Trade Size Knockout 1/2 in. 2 Places (BS2-V) Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 3 Places Trade Size Knockout 1/2 in. 1-7/8 in. 5-3/8 in. 7-5/8 in. 2-1/4 in. 7/8 in. 1/2 in. 1/4 in. K.O. 4-3/16 in. TYPICAL BOTTOM Trade Size Knockout 1, 1-1/4, 1-1/2, 2 and 2-1/2 in. 2 Places Cat. No. BC HYDRO BOTTOM 2-1/8 in. Cuivre et aluminium 2-3/16 in. Description 4 JAW Overhead, hub opening BS2-V Overhead, hub opening c/w 1-1/2 in. hub BS2-1 1/2 V Overhead, hub opening c/w 2 in. hub BS2-2V Underground BS2-TV Combination, overhead-underground BS2-TCV Combination overhead-underground for British Columbia only BS2-TCVBC Combination OH and UG (Fortis Alberta approved) c/w 350 kcmil lug BS2-TCVFA* Overhead, twin hub opening BS2-22VNH Overhead, twin hub opening c/w 2 in. hubs BS2-22V Overhead, hub opening c/w 5th jaw, 9 o’clock & insulated neutral BS2-9-14V FACTORY INSTALLED ACCESSORIES 5th jaw, standard capacity, 9 o’clock position Include: -5 5th jaw, full capacity, 6 o’clock position -6 5th jaw, full capacity, 9 o’clock position -9 Insulated neutral -IN Ground lug on neutral -GN w w w. t n b. c a Trade Size Knockout 1, 1-1/4, 1-1/2, 2, 2-1/2 and 3 in. 2 Places H Dimensions (in.) W D 12 5-7/16 Weight Each lb. kg 17-1/8 14 6.3 27-7/16 17-1/8 D17 Meter Sockets BS2 Series Kit 200 A 600 V; Oversize Enclosure with PVC Accessories Product Specifications • • • • • • Conductor range: 6 AWG-250 kcmil Aluminum tunnel type connectors for both load and line sides For overhead, underground and combination Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in: Ontario only Note: Supply from an underground network often requires use of stud type connector. Consult your local utility. 5-7/16 in. (BS2-TCV-KIT2U) Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 3 Places Trade Size Knockout 1/2 in. 2-1/8 in. 1-7/8 in. 5-3/8 in. 7-5/8 in. 2-1/4 in. 7/8 in. 1/2 in. 1/4 in. K.O. TYPICAL BOTTOM Cat. No. KIT BS2-TCV-KIT2U Consists of BS2-TCV E943J E986J E995J E997JC UA9AJCB-CTN CI1716 PH20 D18 2-3/16 in. Trade Size Knockout 1, 1-1/4, 1-1/2, 2 and 2-1/2 in. 2 Places Description Approved for copper or aluminum Qty. Kit – Meter socket with PVC accessories 200 A meter socket 2 in. terminal adaptor 2 in. LB access fitting 2 in. meter offsets 2 in. clamps 2 in. elbow 90 degree 2 in. nut 2 in. hub 1 2 1 3 1 w w w. t n b. c a Meter Sockets BS2-TCVFA 200 A, 120/240; Single Phase Service Product Specifications • • • • • • Line: #6 AWG to 350 kcmil, Load 2 x #6 AWG – 4/0 Tunnel type connectors for both load and line sides For underground and above ground service Weatherproof Type 3R enclosure Designed and manufactured in Canada Primarily used in: All provinces Application: When distance is a factor larger conductors require larger connectors. 5-7/16 in. 1-1/32 in. 12 in. 1.475 in. 2.5 in. 3.32 in. 27-7/16 in. 1-1/4 in., 1-1/2 in., 2 in., 2-1/2 in. TTrade size K.O. 3-Places 1/2 in. Trade size K.O. O 10.61 in. 2-1/8 in. 2-1/4 in. 1 in., 1-1/4 in., 1-1/2 in., 2 in., 2-1/2 in. Trade size K.O.’s 2 Places 7/8 in. 1-7/8 in. 7-5/8 in. 5-3/8 in. 1/4 in. K.O. 1/ 5-7/8 in. Approved for copper and aluminum Cat. No. 4 JAW BS2-TCVFA w w w. t n b. c a Description Combination overhead and underground 200 A service H Dimensions (in.) W D 27-7/16 12 5-7/16 Weight Each lb. kg 14 6.3 D19 Meter Sockets BS2L Series 200 A 600 V; Oversize Enclosure Lay-In Lug Product Specifications • • • • • • • Same as BS2 Series with the exception that lay-in type connectors are provided Conductor range: 6 AWG-250 kcmil Aluminum lay-in type connectors for both load and line sides For overhead, underground and combination overhead/underground Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in: B.C., Ont. 5-7/16 in. (BS2L-TV) Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 3 Places Trade Size Knockout 1/2 in. 1-7/8 in. 5-3/8 in. 7-5/8 in. 2-1/4 in. 7/8 in. 1/2 in. 1/4 in. TYPICAL BOTTOM Trade Size Knockout 1/2 in., 2 Places Trade Size Knockout 1, 1-1/4, 1-1/2, 2, 2-1/2 and 3 in. 2 Places 2-9/16 in. 1-3/16 in. 1/2 / in. 1/4 in. 4-3/16 in. 4-3/4 in. 9-7/8 in. 2-1/8 in. BC HYDRO BOTTOM 2-3/16 in. Trade Size Knockout 1, 1-1/4, 1-1/2, 2 and 2-1/2 in. 2 Places Approved for copper or aluminum Cat. No. Description 4 JAW 200 A overhead with lay-in lugs BS2L-V 200 A underground with lay-in lugs BS2L-TV 200 A over/under combination with lay-in lugs BS2L-TCV 200 A over/under combination with lay-in lugs (BC) BS2L-TCVBCR 200 A over/under combination water heater lugs BS2L-WTCV 200 A over/under combination with water heater lugs and North York assembly BS2L-WTCVNY FACTORY INSTALLED ACCESSORIES 5th jaw standard capacity Include: -5 5th jaw full capacity, 6 o’clock position -6 5th jaw full capacity, 9 o’clock position -9 Insulated neutral -IN North York assembly -NY Water heater lugs -W D20 H Dimensions (in.) W D 17-1/8 12 5-7/16 Weight Each lb. kg 16 7.2 w w w. t n b. c a Meter Sockets BS2M Series 200 A 600 V; Oversize Enclosure, Subfeed on Load Side Product Specifications • • • • • • • Conductor range: Line: 6 AWG-250 kcmil, Load: 12-1/0 AWG Aluminum tunnel type connector for line side For overhead service only Dual lug subfeed for load side Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in: All provinces (BS2M-V) 5-7/16 in. Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 3 Places Trade Size Knockout 1/2 in. 2-1/4 in. 7/8 in. 1/2 in. 1-7/8 in. 5-3/8 in. 7-5/8 in. Trade Size Knockout 1/4 in. BOTTOM 2-1/8 in. 2-3/16 in. Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 2 Places Approved for copper or aluminum Cat. No. Description 4 JAW BS2M-V Overhead, hub opening w w w. t n b. c a H Dimensions (in.) W D 17-1/8 12 5-7/16 Weight Each lb. kg 15 6.8 D21 Meter Sockets BS4M 200 A 600 V; Oversize Enclosure, Subfeed on Load Side Product Specifications •Conductor range: Line: 6 AWG-250 kcmil Load: 6-4/0 AWG •Aluminum tunnel type connectors for both line and load sides •For overhead service only •Dual lug subfeed connectors for load side •Weatherproof Type 3R enclosure •Primarily used in: Manitoba 5-7/16 in. (BS4M-V) Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 3 Places Trade Size Knockout 1/2 in. Trade Size Knockout 1/2 in. 1/2 in. 2-1/4 in. 1-9/16 in. 1-7/8 in. 3-13/16 in. 2-1/8 in. 3-13/16 in. Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 3 Places Cat. No. BS4M-V D22 Description Overhead hub opening 2-3/16 in. H Dimensions (in.) W D 17 12 5-7/16 Weight Each lb. kg 14.95 6.75 w w w.t nb.c a Meter Sockets MO2 Series 200 A 600 V; Underground Only Product Specifications •Conductor Range: Line: Single 1/2 in. studs to accommodate compression lugs 350 kcmil max. (supplied by utility), Load: 6 AWG-250 kcmil •For underground service only •Aluminum tunnel type connectors for load side, 1/2 in. studs on line side •Supplied with screw type ring •Weatherproof Type 3R enclosure •Primarily used in: Sask., Man., Ont., Que. (MO2-V) 9-5/16 in. Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 3 Places 7/8 in. Trade Size Knockout 1, 1-1/4, 1-1/2, 2, 2-1/2 and 3 in. 2 Places Trade Size Knockout 7/8 in. 2 Places 19-1/8 in. 1-7/8 in. 4-3/16 in. 5-3/8 in. 7-5/8 in. 4-3/4 in. 1/4 in. 1/4 in. 9-7/8 in. MO2-VO BOTTOM MO2-V BOTTOM 2 in. 2-5/16 in. Approved for copper or aluminum Cat. No. Description 4 JAW Underground 1/2 in. studs MO2-V Underground 1/2 in. studs for Ontario MO2-VO FACTORY-INSTALLED ACCESSORIES Water heater lugs Include:-W 2/0 AWG subfeed on load side -M w w w. t nb. c a H Dimensions (in.) W D 19-1/8 12 9-5/16 Weight Each lb. kg 18 8.1 D23 Meter Sockets MO2 Series Kit 200 A 600 V; Underground Only with PVC Accessories Product Specifications • Conductor range: Line: Single 1/2 in. studs to accommodate compression lugs (supplied by utility), Load: 6 AWG-250 kcmil • For underground service only • Aluminum tunnel type connectors for load side • Supplied with screw type ring • Weatherproof Type 3R enclosure • Primarily used in: Ontario Only 5-9/16 in. (MO2-VO-KIT2U) Trade Size Knockout 1, 1-1/4, 1-1/2, 2, 2-1/2 and 3 in. 3 Places 7/8 in. 19-1/8 in. 1-7/8 in. 5-3/8 in. 1/4 in. 7-5/8 in. 2 in. MO2-VO BOTTOM 2-5/16 in. Approved for copper or aluminum Cat. No. KIT MO2-VO-KIT2U Consists of MO2-VO CI1716 E943J E977JC E986J E995J UA9AJCB-UPC D24 Description Qty. Kit – Meter socket with PVC accessories 200 A Meter Socket 2 in. Locknut 2 in. Male Adaptor 2 in. Pipe Strap 2 in. Conduit Bodies – LB Type 2 in. Meter Offsets 2 in. 90o Elbow 1 3 1 2 1 2 1 w w w. t n b. c a Meter Sockets MO2 Series Kit 200 A 600 V; Underground Only with PVC Accessories Product Specifications • Conductor range: Line: Single 1/2 in. studs to accommodate compression lugs (supplied by utility), Load: 6 AWG-250 kcmil • For underground service only • Aluminum tunnel type connectors for load side, 1/2 in. studs on line side • Supplied with screw type ring • Weatherproof Type 3R enclosure • Primarily used in: Quebec Only 5-9/16 in. (MO2-V-KIT1-1/4U) Trade Size Knockout 1, 1-1/4, 1-1/2, 2, 2-1/2 and 3 in. 2 Places Trade Size Knockout 7/8 in. 2 Places 19-1/8 in. 4-3/16 in. 4-3/4 in. 2 in. 9-7/8 in. 1/4 in. MO2-V BOTTOM Approved for copper or aluminum 2-5/16 in. Cat. No. KIT MO2-V-KIT1-1/4U Consists of MO2-V CE942RL CI1710 CI1724 CI-DUCT-1 E943G E943L E945L E977GC E977LC-CAR E986G UA9AGCB-UPC w w w. t n b. c a Description Qty. Meter socket with PVC accessories 200 A Meter Socket 3 in. PVC/DB2 Adaptor 1-1/4 in. nut 3 in. nut Duct Seal 1-1/4 in. Male Adaptor 3 in. Male Adaptor 3 in. Expansion Fitting 1-1/4 in. Pipe Strap 3 in. Pipe Strap 1-1/4 in. Conduit Bodies – LB Type 1-1/4 in. 90o Elbow 1 2 1 2 1 Cat. No. KIT MO2-V-KIT2U Consists of MO2-V CE942RL CI1716 CI1724 CI-DUCT-1 E943J E943L E945L E977JC E977LC-CAR E986J UA9AJCB-UPC Description Qty. Meter socket with PVC accessories 200 A Meter Socket 3 in. PVC/DB2 Adaptor 2 in. nut 3 in. nut Duct Seal 2 in. Male Adaptor 3 in. Male Adaptor 3 in. Expansion Fitting 2 in. Pipe Strap 3 in. Pipe Strap 2 in. Conduit Bodies – LB Type 2 in. 90o Elbow 1 2 1 2 1 D25 Meter Sockets BD2 Series 200 A (Main Lugs) 600 V; Multiple Position – 200 A per Position Product Specifications •Conductor range: Line: 6 AWG-250 kcmil, Load: 6 AWG-250 kcmil •Aluminum tunnel type connectors for both load and line sides •Factory prebussed from main lugs to each position •Supplied with hub opening closure plate for underground service •Combination overhead underground •Supplied with screw type rings •Weatherproof Type 3R enclosure •Primarily used in: All provinces (BD2-V) Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. Typical Trade Size Knockout 1/2 in. 2 Places Trade Size Knockout 1-1/2, 2, 2-1/2 and 3 in. Typical 2-1/4 in. 2-1/16 in. H 1-3/16 in. 4-5/16 in. 8-3/4 in. Steps 8-3/4 in. 8-3/4 in. 2-1/2 in. 2-7/16 in. 2-1/4 in. 1-3/16 in. 1-3/16 in. 2-3/16 in. 4-3/8 in. 5-7/16 in. Steps 8-3/4 in. 1-3/16 in. Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 4 Places Note: Pattern for bottoms. Left hand entry is shown. For right-hand entry, unit is manufactured symmetrically with hub openings, knockout and line connections on right side. Meter Position Cat. No. 4 JAW LEFT-HAND ENTRY BD2-V BD3-V BD4-V BD2-VBC D26 RIGHT-HAND ENTRY BD2-VH BD3-VH BD4-VH BD2-VBCH 2 position 3 position 4 position 2 position for British Columbia Approved for copper or aluminum H 15-1/2 20 Dimensions (in.) W 17-1/2 26-1/4 35 17-1/2 D 5-7/16 Weight Each lb. kg 23 35 47 27 10.4 15.9 21.3 12.2 w w w.t nb.c a Meter Sockets BDA2-V Series 200 A (Main Lugs) 600 V; Multiple Position with Blank Compartment 200 A per position Product Specifications • • • • • • • Conductor range: Line: 6 AWG-250 kcmil, Load: 6 AWG-250 kcmil Aluminum tunnel type connectors for load side Combination overhead and underground Hub opening closure plate for underground service Supplied with screw type rings Weatherproof Type 3R enclosure Primarily used in: Ontario only (BDA2-V) D H Trade Size Knockout 1-1/4, 1-1/2, 2, 2-1/2 and 3 in. 2 Places Trade Size Knockout 1/4 in. 2 Places 8-11/16 in. 4-5/16 in. 4-5/16 in. 2-1/2 in. 2-1/2 in. 1-1/4 in. 2-3/8 in. 7/8 in. 2-11/16 in. 5-9/16 in. Trade Size Knockout 1-1/2, 2, 2-1/2 and 3 in. 2 Places 1-1/4 in. 2-1/4 in. Approved for copper or aluminum Cat. No. Meter Position H Dimensions (in.) W D 15-5/8 26-3/16 5-1/4 Weight Each lb. kg 4 JAW LEFT-HAND ENTRY BDA2-V w w w. t n b. c a RIGHT-HAND ENTRY BDA2-VH 2 position 31 14.6 D27 Meter Sockets BDC Series 200 A (Main Lugs) 600 V; Stud Type Multiple Position with Blank Compartment 200 A per Position Product Specifications •Conductor Range: Line: Single 1/2 in. studs to accommodate compression lugs (supplied by utility), Load: 6 AWG-250 kcmil •Aluminum tunnel type connectors for load sides •For underground service only •Factory prebussed from main lugs to each position •Supplied with screw type sealing rings •Weatherproof Type 3R enclosure •Primarily used in: All provinces (BDC2-VIL) Trade Size K.O.’s 1/2 in. 2 Places 2-7/16 in. 1-9/16 in. Trade Size K.O.’s 1-1/4, 1-1/2, 2 and 2-1/2 in. Typical Trade Size K.O.’s 1-1/2, 2, 2-1/2 and 3 in. Typical 2-1/4 in. 1-3/16 in. 2-7/16 in. 1-1/8 in. 4-5/16 in. 13-1/8 in. Typical Trade Size K.O.’s 1-1/2, 2, 2-1/2 and 3 in. Typical 4-3/8 in. Typical Trade Size K.O.’s 1/2 in. 2 Places 4-3/8 in. 1-3/16 in. Typical 15-5/8 in. Trade Size K.O.’s 1-1/4, 1-1/2, 2 and 2-1/2 in. Typical 2-3/16 in. 1-1/16 in. 2-5/16 in. 2-5/16 in. 2-5/8 in. 5-1/2 in. Note: Pattern for bottoms. Left hand entry is shown. For right-hand entry, unit is manufactured symmetrically with hub openings, knockouts for line connectors on right side. 4-5/16 in. 4-7/16 in. Typical Typical 8-3/4 in. Typical 13-1/8 in. Typical 1-3/16 in. 2-3/16 in. Copper or aluminum For use in All Provinces Cat. No. Left-Hand Entry Right-Hand Entry 4 JAW BDC2-V BDC3-V BDC4-V BDC2-VH BDC3-VH BDC4-VH Meter Position Dimensions (in.) H W Weight Each D 2 position 26-1/4 3 position 15-5/8 35 5-1/4 4 position 43-3/4 lb. kg 30 42 54 13.6 19.0 24.5 4 JAW BDC2-VIL BDC3-VIL BDC4-VIL Right-Hand Entry Copper or aluminum Meter Position Dimensions (in.) H W D 4 JAW BDC2-VAILBC BDC2-VAHILBC 2 position 26-1/4 5-1/4 BDC3-VAILBC BDC3-VAHILBC 3 position 20-3/4 35 BDC4-VAILBC BDC4-VAHILBC 4 position Locking system inside meter section, comes with tunnel type connector on line side. D28 Right-Hand Entry BDC2-VHIL BDC3-VHIL BDC4-VHIL Meter Position Dimensions (in.) Weight Each H lb. kg 30 42 54 13.6 19.0 24.5 W D 2 position 26-1/4 3 position 15-5/8 35 5-1/4 4 position 43-3/4 Locking system inside meter section. For use in British Colombia Left-Hand Entry Copper or aluminum For use in Quebec Cat. No. Left-Hand Entry Locking system outside meter section. Cat. No. 2-1/2 in. Weight Each lb. kg 30 13.6 42 19.0 Copper or aluminum For use in Ontario Cat. No. Left-Hand Entry 5 JAW BDC2-5V BDC3-5V BDC4-5V Dimensions (in.) Meter Position 2 position 3 position 4 position Weight Each H W D lb. kg 15-5/8 26-1/4 35 43-3/4 5-1/4 30 42 54 13.6 19.0 24.5 Locking system outside meter section. w w w.t nb.c a Meter Sockets BS4 Series 400 A (Main Lugs) 600 V; Multiple Position with Blank Compartment 200 A per Position Product Specifications • Conductor range: Line: Dual rated connectors for 1 x 4 AWG-600 kcmil or 2 x 1/0 AWG-250 kcmil, Load: 6 AWG-250 kcmil • Aluminum tunnel type connectors for both load and line sides • Factory prebussed from main lugs to each position • Combination overhead-underground • Supplied with hub opening closure plate for underground service • Larger hub opening requires use of 3 in. , 3-1/2 in. or 4 in. hubs unless BS052 adapter plate is used • Supplied with screw type rings • Weatherproof Type 3R enclosure • Primarily used in: All provinces (BS42-V) Tunnel type connector 1/2 in. Stud Connection Compression Lug 5-5/16 in. TUNNEL TYPE CONNECTOR TERMINATION LOAD AND LINE Trade Size Knockout 2, 2-1/2, 3 and 3-1/2 in. 1 Place 23-3/8 in. Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. Typical Trade Size Knockout 1/2 in. 1 Place COMPRESSION LUG TERMINATION (WITH STUD CONNECTION) 500 KCMIL MAX. UNDERGROUND APPLICATION COMPRESSION CONNECTOR SUPPLIED BY UTILITY. Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. Typical Trade Size Knockout 2, 2-1/2, 3 and 3-1/2 in. 1 Place 2-7/8 in. 2-3/8 in. Trade Size Knockout 1/2 in. 1 Place 1-1/8 in. 4-5/16 in. 13-1/16 in. 8-3/4 in. 8-3/4 4-5/16 in. 13-1/16 in. 8-3/4 in. 8-3/4 in. Approved for copper or aluminum Cat. No. 4 JAW LEFT-HAND ENTRY BS42-V BS43-V BS44-V BS45-V BS46-V w w w. t n b. c a Meter Position RIGHT-HAND ENTRY BS42-VH BS43-VH BS44-VH BS45-VH BS46-VH 2 position 3 position 4 position 5 position 6 position H 23-3/8 Dimensions (in.) W 26-1/4 35 43-3/4 52-1/2 61-1/4 D 5-5/16 Weight Each lb. kg 45 59 73 87 101 20.4 26.8 33.1 39.5 45.9 D29 Meter Sockets BSC4-G Series 400 A (Main Lugs) 600 V; Stud Type Multiple Position with Blank Compartment 200 A per Position Product Specifications • Conductor range: Line: Single 1/2 in. studs to accommodate compression lugs (supplied by utility), Load: 6 AWG-250 kcmil • Aluminum tunnel type connectors for load side • For underground service only • Twin wiring compartment, increased length of the busbars and double 1/2 in. studs to accommodate compression lugs • Supplied with screw type rings • Weatherproof Type 3R enclosure • Primarily used in: Ontario and British Columbia (BSC42-VGA) Trade Size Knockout 1/2 in. 1 Place Trade Size Knockout 2, 2-1/2, 3 and 3-1/2 in. 1 Place Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. Typical 20-1/8 in. 2-3/8 in. 2-15/16 in. 1-1/4 in. 1-1/4 in. 4-3/8 in. 13-1/8 in. 8-3/4 in. 8-3/4 in. 6-3/8 in. Approved for copper or aluminum For use in Ontario Cat. No. Left-Hand Entry BSC42-VG BSC43-VG BSC44-VG BSC45-VG BSC46-VG Right-Hand Entry BSC42-VGH BSC43-VGH BSC44-VGH BSC45-VGH BSC46-VGH Meter Position Dimensions (in.) H 2 position Weight Each D 35 3 position 4 position W 43-3/4 23-3/8 52-1/2 5-5/16 Cat. No. D30 Right-Hand Entry BSC42-VGAH BSC43-VGAH BSC44-VGAH BSC45-VGAH BSC46-VGAH kg 58 26.3 72 32.7 86 39.0 5 position 61-1/4 100 45.4 6 position 70 114 51.8 Approved for copper or aluminum For use in British Columbia Left-Hand Entry BSC42-VGA BSC43-VGA BSC44-VGA BSC45-VGA BSC46-VGA lb. Meter Position Dimensions (in.) H 2 position Weight Each D 35 3 position 4 position W 43-3/4 23-3/8 52-1/2 5-5/16 lb. kg 58 26.3 72 32.7 86 39.0 5 position 61-1/4 100 45.4 6 position 70 114 51.8 w w w. t n b. c a Meter Sockets PL27 Series 200 A 600 V; Polyphase Product Specifications • • • • Conductor range: 6 AWG-250 kcmil Tunnel type connector for both load and line sides For overhead and combination overhead/underground service Larger hub opening requires use of 3 in., 3-1/2 in. or 4 in. hubs unless BS052 adapter plate is used • Supplied with screw type ring • Weatherproof Type 3R enclosure • Primarily used in: All provinces 5-7/16 in. (PL27-V) Trade Size Knockout 1/4 in. Trade Size Knockout 1-1/2, 2, 2-1/2 and 3 in. 2 Places 1/2 in. 2-9/16 in. 1-3/16 in. 1-3/4 in. Trade Size Knockout 1/2 in. Trade Size Knockout 1-1/2, 2, 2-1/2 and 3 in. 2 Places Trade Size Knockout 1-1/2, 2, 2-1/2 and 3 in. 2 Places Trade Size Knockout 1/2 in. 2-3/8 in. 2-11/16 in. 4-3/4 in. 2-3/8 in. Trade Size Knockout 1/2 in. 15/16 in. 15/16 in. 1-11/16 in. 5/16 in. Trade Size Knockout 1/4 in. 5-5/16 in. Cat. No. Description Approved for copper or aluminum H Dimensions (in.) W D 20-1/8 12 5-7/16 Weight Each lb. kg 7 JAW PL27-V Overhead hub opening PL27-TCV Combination overhead-underground PL27-IN-V Overhead hub opening, Insulated neutral PL27-IN-TCV Combination overhead-underground, Insulated neutral w w w. t n b. c a 18 8.1 D31 Meter Sockets CO2 Series 200 A 120/240 V; Combination with or without Breaker Product Specifications •Conductor range (Line and Load): 1 AWG-250 kcmil •Aluminum tunnel type connectors for both load and line sides •For overhead and underground services •With factory-installed neutral conductor •Suitable for 120/240 V single phase service entrance for mobile homes, trailers, temporary services, recreational parks and other commercial 5-7/16 in. and residential locations •Factory installed 2 pole circuit breaker, 10,000 A rms interrupting capacity •With adjustable bracket for field installation to accept Cutler Hammer (ED, EDH) breakers • “QJ” Type Siemens breaker •Supplied with screw type rings •Weatherproof Type 3R enclosure •Primarily used in: All provinces Quebec only: As per Hydro-Québec spec (supplied with 22 kA Siemens breaker) 32-3/4 in. (CO2-200) 7-5/8 in. CAT. NO.: CO3417M-1-FG Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 6 Places Trade Size Knockout 1/4 in. 1 Place 7/8 in. 2-1/4 in. 1/2 in. 4-1/6 in. Trade Size Knockout 1/2 in. 1 Place 2-3/16 in. 2-1/4 in. 9/16 in. Approved for copper or aluminum Type Description 4 JAW CO2 CO2-125 CO2-125-5V CO2-125HI CO2-150 CO2-150-5V CO2-150HI CO2-200 CO2-200-5V CO2-200HI CO2-200G CO2-200GM CO2-G Overhead Overhead Overhead Overhead Overhead Overhead Overhead Overhead Overhead Overhead Underground Underground Underground CO2-GMB Underground Provision for Siemens (QJ), 200 A 2 pole 10 kA rated circuit breaker c/w Siemens QJ 125 A 2 pole 10 kA rated circuit breaker c/w Siemens QJ 125 A 2 pole 10 kA rated circuit breaker, c/w 5th jaw c/w Siemens QJH 125 A 2 pole 22 kA rated circuit breaker c/w Siemens QJ 150 A 2 pole 10 kA rated circuit breaker c/w Siemens QJ 150 A 2 pole 10 kA rated circuit breaker, c/w 5th jaw c/w Siemens QJH 150 A 2 pole 22 kA rated circuit breaker c/w Siemens QJ 200 A 2 pole 10 kA rated circuit breaker c/w Siemens QJ 200 A 2 pole 10 kA rated circuit breaker, c/w 5th jaw c/w Siemens QJH 200 A 2 pole 22 kA rated circuit breaker c/w Siemens QJ 200 A 2 pole 10 kA rated circuit breaker, c/w gutter c/w Siemens QJ 200 A 2 pole 10 kA rated circuit breaker and adjustable bracket, c/w gutter Provision for Siemens (QJ), 200 A 2 pole 10 kA rated circuit breaker, c/w gutter Atco, Alberta; provision for Siemens (QJ), Cutler Hammer (ED, EDH), 200 A 2 pole 10 kA rated circuit breaker, c/w pole mount kit, 2 x 3306 connectors, c/w gutter Cat. No. H Dimensions (in.) W D 32-3/4 11-13/16 Weight Each lb. kg 28 12.7 30 13.6 32.6 30 14.6 13.6 28 12.7 5-7/16 Note: Some local utilities require a gutter option for underground services. Order with suffix -G. Please check with local supply authority if mechanical connectors are accepted for underground services. D32 w w w.t nb.c a Meter Sockets CO2M Series 200 A – Single Phase 120/240 V; Combination with or without Breaker and Splitter Product Specifications •Conductor range (Line and Load): 6 AWG-250 kcmil •Tunnel type connectors for both load and line sides •For combination overhead/underground service only • Cutler Hammer (ED, EDH) breaker to be field-installed • With CO2FB braid connector (also available for field installation cat. no.: CO2FB-KIT) •Primarily used in: Alberta 5-7/16 in. Trade Size Knockout 1-1/2 and 2 in. 2 Places 3-3/8 in. 7/16 in. Trade Size Knockout 1/2, 3/4, 1 and 1-1/4 in. 3 Places 2 in. 1-11/16 in. 1-11/16 in. 1-1/2 in. 9/16 in. 4-3/8 in. 4-3/16 in. Trade Size Knockout 1/4 in. 2 Places (C02M) 3-7/8 in. 2-3/4 in. 1/2 in. 2-11/16 in. CO2MS 3-13/16 in. Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 5 Places 3-13/16 in. Trade Size Knockout 1/2 in. 1 Place CAT. NO.: CO2FB-KIT 2-1/4 in. 1/2 in. 7/8 in. 1-7/8 in. 2-5/8 in. Trade Size Knockout 1/4 in. 1 Place 5-15/16 in. 9/16 in. CO2M 2-3/16 in. Type Cat. No. Description Approved for copper or aluminum H Dimensions (in.) W D Weight Each lb. kg 4 JAW CO2M CO2MS CO2MS-1 1/4 Combination OH/UG CO2MS-2446 CO2MSB-200 CO2MSU Underground Provision for field-installed Cutler Hammer (ED, EDH) 200 A 2 pole 10 kA rated circuit breaker, provision for pole mounting (splitter not included) Provision for field-installed Cutler Hammer (ED, EDH) 200 A 2 pole 10 kA rated circuit breaker, provision for pole mounting (splitter included) Provision for field-installed Cutler Hammer (ED, EDH) 200 A 2 pole 10 kA rated circuit breaker, provision for pole mounting, c/w 1-1/4 hub (splitter included) Provision for field-installed Cutler Hammer (ED, EDH) 200 A 2 pole 10 kA rated circuit breaker, provision for pole mounting, c/w 2446 connector (splitter included), Fortis Alberta approved c/w Siemens QJ 200 A 2 pole 10 kA rated circuit breaker, c/w neutral bar (splitter included) Provision for field-installed Cutler Hammer (ED, EDH) 200 A 2 pole 10 kA rated cicuit breaker, pedestal type for padmount applications (splitter included) 30-5/8 39-3/8 60 12 28 12.7 42 19 44 19.5 47 21.3 59 26.8 5-7/16 Note: Mounting brackets are now shipped unassembled inside each unit where applicable. w w w. t nb. c a D33 Meter Sockets CO22 Series 200 A (Main Lugs), 200 A per Position, Single Phase 120/240 V; Multiple Position Comb ination with or without Breaker Product Specifications •Conductor range: Line: 6 AWG-250 kcmil, Load: 6 AWG-250 kcmil •Aluminum tunnel type connectors for both load and line sides •For overhead and underground services •Factory pre-bussed from main lugs to each position •Supplied with hub opening closure plate for underground service •Internal locking system for covers •Supplied with screw type sealing rings •Factory installed 2 pole circuit breaker, 10,000 A rms interrupting capacity •Siemens Type “QJ” breaker •With adjustable breaker plate for field installation of Square D and Eaton breakers •Weatherproof Type 3R enclosure •Primarily used in: All provinces, Quebec only: As per Hydro-Québec spec 5-1/2 in. (supplied with 22 kA Siemens breaker) C H Note: Consult your Regional Sales Office for right-hand entry option. 1-7/16 in. Trade Size Knockout 1-1/2, 2, 2-1/2 and 3 in. 1 Place Trade Size Knockout 1/2 in. 2 Places Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 4 Places 1-7/16 in. 1-9/16 in. 7-1/8 in. 2-1/4 in. 2-7/16 in. 1-3/16 in. 1-1/8 in. 4-5/16 in. Hub Cat. No. MH10X MH12X MH15 MH20 MH25 4-3/8 in. 8-3/8 in. 30 in. 26-15/16 in. Hub C H Size (in.) (in.) 1 1-7/16 1-1/8 1-1/4 1-5/8 1-1/32 1-1/2 1-11/16 1-1/32 2 1-15/16 1-1/32 2-1/2 2-1/8 1-7/16 Approved for copper or aluminum Cat. No. Type Left-Hand Entry CO22 CO22-200 CO22-200HI CO23 Combination CO23-200 OH/UG* CO23-200HI CO24 CO24-200 CO24-200HI Description 2 gang, provision for Siemens 2 x (QJ), 200 A 2 pole 10 kA rated circuit breakers 2 gang, c/w Siemens 2 x QJ 200 A 2 pole 10 kA rated circuit breakers 2 gang with blank compartment, c/w Siemens 2 x QJH 200 A 2 pole 22 kA rated circuit breakers 3 gang, provision for Siemens 3 x (QJ), 200 A 2 pole 10 kA rated circuit breakers 3 gang, c/w Siemens 3 x QJ 200 A 2 pole 10 kA rated circuit breakers 3 gang with blank compartment, c/w Siemens 3 x QJH 200 A 2 pole 22 kA rated circuit breakers 4 gang, provision for Siemens 4 x (QJ), 200 A 2 pole 10 kA rated circuit breakers 4 gang, c/w Siemens 4 x QJ 200 A 2 pole 10 kA rated circuit breakers 4 gang with blank compartment, c/w Siemens 4 x QJH 200 A 2 pole 22 kA rated circuit breakers Position Dimensions (in.) H W D 2 3 4 30 Weight Each lb. kg 17-1/2 40 26-1/4 60 27.21 26-1/2 60 27.21 35 80 36.29 35-1/4 80 36.28 43-3/4 100 45.36 5-1/2 18.14 Note: Ex. CO22-XXX, suffix (XXX) can be replaced by any of the following breaker amperage options: 100, 125 or 150. Consult your Regional Sales Office for price and availability. *Only allowed for underground use if local utility authority does not require a blank compartment. If blank compartment is required, recommend CO22-U. D34 w w w.t nb.c a Meter Sockets CO22-U Series 200 A (Main Lugs), 200 A per Position, Single Phase 120/240 V; Multiple Position Combination with Compartment with or without Breaker Product Specifications •Conductor range: Line: Single 1/2 in. stud to accommodate compression lugs (supplied by utility), Load: 6 AWG-250 kcmil •Aluminum tunnel type connectors for load sides •For underground service only •Factory pre-bussed from main lugs to each position • Internal locking system for covers • Supplied with screw type sealing rings • Factory installed 2 pole circuit breaker, 10,000 A rms interrupting capacity •Siemens Type “QJ” breaker • With adjustable breaker plate for field installation of Square D and Eaton breakers • Weatherproof Type 3R enclosure •Primarily used: All Provinces Quebec only: As per Hydro-Québec spec (supplied with 22 kA Siemens breaker) Note: Consult your Regional Sales Office for right-hand entry option. 8-13/16 in. 1-7/16 in. 1-7/16 in. 5-1/2 in. 1-9/16 in. 7-1/8 in. 30 in. 26-15/16 in. Trade Size Knockout 1-1/2, 2, 2-1/2 and 3 in. 2 Places Trade Size Knockout 1/2 in. 2 Places 2-7/16 in. 1-3/16 in. 1-3/16 in. Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 in. 4 Places 2-1/4 in. 4-5/16 in. 8-3/4 in. 4-3/8 in. 8-3/4 in. Approved for copper or aluminum Cat. No. Type Description Position Dimensions (in.) H W D 2 26-1/4 Weight Each lb. kg Left-Hand Entry CO22-U CO22-200-U CO22-200HI-U CO23-U Underground only CO23-200-U CO23-200HI-U CO24-U CO24-200-U CO24-200HI-U 2 gang with blank compartment, provision for Siemens 2 x (QJ), 200 A 2 pole 10 kA rated circuit breakers 2 gang with blank compartment, c/w Siemens 2 x QJ 200 A 2 pole 10 kA rated circuit breakers 2 gang with blank compartment, c/w Siemens 2 x QJH 200 A 2 pole 22 kA rated circuit breakers 3 gang with blank compartment, provision for Siemens 3 x (QJ), 200 A 2 pole 10 kA rated circuit breakers 3 gang with blank compartment, c/w Siemens 3 x QJ 200 A 2 pole 10 kA rated circuit breakers 3 gang with blank compartment, c/w Siemens 3 x QJH 200 A 2 pole 22 kA rated circuit breakers 4 gang with blank compartment, provision for Siemens 4 x (QJ), 200 A 2 pole 10 kA rated circuit breakers 4 gang with blank compartment, c/w Siemens 4 x QJ 200 A 2 pole 10 kA rated circuit breakers 4 gang with blank compartment, c/w Siemens 4 x QJH 200 A 2 pole 22 kA rated circuit breakers 3 4 30 35 43-3/4 5-1/2 60 27.21 80 36.29 100 45.36 Note: Ex. CO22-XXX, suffix (XXX) can be replaced by any of the following breaker amperage options: 100, 125 or 150. Consult your Regional Sales Office for price and availability. w w w. t nb. c a D35 Meter Sockets CO42 Series 400 A (Main Lugs), 200 A per Position, Single Phase 120/240 V; Multiple Position Combination with Compartment with or without Breaker Product Specifications 5-1/2 in. D C 2-5/8 in. H1 H2 4-3/8 in. 1-7/8 in. 2-5/8 in. •Conductor range: Line: Dual rated connectors for 1 x 4 AWG-600 kcmil or 2 x 1/0 AWG-250 kcmil, Load: 6 AWG-250 kcmil •Aluminum tunnel type connectors for both load and line sides •Combination overhead/underground •Factory pre-bussed from main lugs to each position • Supplied with hub opening closure plate for underground service • Internal locking system for covers •Larger hub opening requires use of 3 in., 3-1/2 in., or 4 in. hubs unless BS052 adaptor plate is used • Supplied with screw type rings • Factory installed 2 pole circuit breaker, 10,000 A rms interrupting capacity • Siemens Type “QJ” breaker •With adjustable breaker plate for field installation of Square D and Eaton breakers • Weatherproof Type 3R enclosure •Primarily uses in: All Provinces Quebec only: As per Hydro-Québec spec (supplied with 22 kA Siemens breaker) Note: Consult your Regional Sales Office for right-hand entry option. 26-1/4 in. 1-5/8 in. 1-9/16 in. 1-5/8 in. 1-5/8 in. 2-1/2 in. 2-3/8 in. 4-3/8 in. Hub Cat. No. 34.594 in. Trade Size Knockout 1-1/4, 1-1/2, 2 and 2-1/2 1-1/4 in. 1-3/16 in. 37-21/32 in. Trade Size Knockout 1 Place 2, 2-1/2, 3, 3-1/2 Trade Size Knockout 1 Place 1/2 in. 8-3/4 in. 8-3/4 in. Hub Size C (in.) D (in.) H1(in.) H2 (in.) MH10X MH12X MH15 MH20 MH25 MH30 MH35 MH40 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 1-7/16 N/A 1-5/8 N/A 1-11/16 N/A 1-15/16 N/A 2-1/8 N/A N/A 2-7/16 N/A 2-7/8 N/A 2-7/8 1-1/8 1-1/32 1-1/32 1-1/32 1-7/16 N/A N/A N/A N/A N/A N/A N/A N/A 1-1/2 1-1/2 1-1/2 Approved for copper or aluminum Cat. No. Type Left-Hand Entry CO42 CO42-200 CO42-200HI CO43 Combination CO43-200 OH/UG CO43-200HI CO44 CO44-200 CO44-200HI Description 2 gang with blank compartment, provision for Siemens 2 x (QJ), 200 A 2 pole 10 kA rated circuit breakers 2 gang with blank compartment, c/w Siemens 2 x QJ 200 A 2 pole 10 kA rated circuit breakers 2 gang with blank compartment, c/w Siemens 2 x QJH 200 A 2 pole 22 kA rated circuit breakers 3 gang with blank compartment, provision for Siemens 3 x (QJ), 200 A 2 pole 10 kA rated circuit breakers 3 gang with blank compartment, c/w Siemens 3 x QJ 200 A 2 pole 10 kA rated circuit breakers 3 gang with blank compartment, c/w Siemens 3 x QJH 200 A 2 pole 22 kA rated circuit breakers 4 gang with blank compartment, provision for Siemens 4 x (QJ), 200 A 2 pole 10 kA rated circuit breakers 4 gang with blank compartment, c/w Siemens 4 x QJ 200 A 2 pole 10 kA rated circuit breakers 4 gang with blank compartment, c/w Siemens 4 x QJH 200 A 2 pole 22 kA rated circuit breakers Position Dimensions (in.) H W D Weight Each lb. kg 2 26-1/4 75 39 3 37-1/2 39-3/8 5-1/2 100 36.29 4 43-1/2 125 56.70 Note: Ex. CO42-XXX, suffix (XXX) can be replaced by any of the following breaker amperage options: 100, 125 or 150. Consult your Regional Sales Office for price and availability. D36 w w w.t nb.c a Meter Sockets CO27 Series 200 A, 120/208 /208 V; Combination Polyphase with Breaker Product Specifications • • • • • • • • • • Conductor range (Line and Load): 2 AWG-250 kcmil Aluminum tunnel type connectors Suitable for 120/208 V polyphase service entrance For overhead installation Larger hub opening requires use of 3 in., 3-1⁄2 in. or 4 in. hubs unless BS052 adaptor plate is used Factory installed 3 pole circuit breaker, 10,000 A rms interrupting capacity “QJ” Type Siemens 10 kA breaker Weatherproof Type 3R enclosure Supplied with screw type rings Primarily uses in: All Provinces Quebec only: As per Hydro-Québec spec (supplied with 22 kA Siemens breaker) A 5-1/2 in. 6-1/8 in. 2-1/2 in. 12 in. Trade Size Knockout 1/4 in. Trade Size Knockout 1/2 in. 1-9/16 in. 9-13/16 in. 2-1/4 in. 4-3/4 in. 47/64 in. 1-1/2 in. 1-31/64 in. 3-11/16 in. Hub Cat. No. MH30 MH35 MH40 Hub Size 3 3-1/2 4 32-13/16 in. A (in.) 2-5/16 2-3/4 2-3/4 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 in. 3 Sets 1-9/16 in. 2-1/4 in. Approved for copper or aluminum Cat. No. Type Left-Hand Entry c/w Breaker CO27B-100 Overhead CO27B-150 CO27B-200 w w w. t n b. c a Description c/w Siemens QJ 100 A 3 pole 10 kA rated circuit breaker c/w Siemens QJ 150 A 3 pole 10 kA rated circuit breaker c/w Siemens QJ 200 A 3 pole 10 kA rated circuit breaker H Dimensions (in.) W D 32-3/4 11-13/16 5 -7/16 Weight Each lb. kg 30 13.6 D37 Meter Sockets BP320 Series 320 A 600 V Self Contained Meter Socket Product Specifications Overhead Product Specifications Underground •320 A overhead 600 V maximum •Self-contained meter socket with bypass mechanism •Single phase service •Line and load side termination; tunnel type connectors; Dual rated for 1 x 500 kcmil or 2 x 250 kcmil •Neutral termination; tunnel type connectors; Dual rated 2 x 250 kcmil •Supplied with screw type sealing ring • Weatherproof type 3R enclosure •Primarily uses in: All Provinces •320 A underground 600 V maximum •Self-contained meter socket with bypass mechanism •Single phase service •Neutral and line side terminations; double 1/2 in. studs to accomodate compression lugs for underground service (1 x 500 kcmil or 2 x 250 kcmil) • Load side terminations; tunnel type connectors; Dual rated for 1 x 500 kcmil or 2 x 250 kcmil •Neutral load side terminations; tunnel type connectors; Dual rated 2 x 250 kcmil •Supplied with screw type sealing ring • Weatherproof type 3R enclosure •Primarily uses in: All Provinces CAT. NO.: BP250 (BP320-V) OVERHEAD UNDERGROUND Approved for copper or aluminum Cat. No. BP320-V BP320-V-08 BP320-V-09 BP320-V-11 BP320-TV BP320-TV-08 BP320-TV-09 BP320-TV-11 Accessory BP250 D38 Type OH UG Description Overhead 320 A 120/240 with bypass mechanism Underground 320 A 120/240 with bypass mechanism Color Position Grey Dark Grey White Beige Grey Dark Grey White Beige 1 H Dimensions (in.) W D 34-1/16 15-9/16 5-15/16 Weight Each lb. kg 47 21.31 Connector kit 2 x 250 kcmil w w w.t nb.c a Meter Sockets FA4B-6T 400 A 600 V; “All In One” Transformer Rated Product Specifications • • • • • • • • • Max. single conductor 600 kcmil Cu or Dual parallel conductors 250 kcmil Cu/Al Load and line side termination at discretion of utility For underground service only Meter socket configuration for 6 jaws Complete with 6 pole test switch Complete with 2 fuseholders and 3 A 32 V fuses Installation of current transformer at discretion of utility Two 1, 1-1/4, 1-1/2, 2, 2-1/2 and 3 in. bottom K.O.’s Permanent red nameplate affixed to front cover warns that removal of meter does not isolate the load terminals; also warning to short circuit current transformer (secondary) before removal of meter • Weatherproof Type 3R enclosure • Primarily used in: Alberta 13-5/16 in. Note: Photo is of an installed meter socket; current transformers are not included. 2-1/2 in. 5 in. 8-3/4 in. 5-5/16 in. 8-1/2 in. Trade Size Knockout 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 and 4 in. 4 Places (FA4B-6T) 40-5/8 in. RED WHT YEL WHT RED BLK RED BLK YEL BLK 43-3/4 in. 19-1/8 in. F1 3A F2 3A GRN 6-1/6 in. 1-9/16 in. Knockout 1, 1-1/4, 0.21 in. 1-1/2, 2, 2-1/2 and 3 Knockout 1/2 in. 3-1/2 in. 3-1/2 in. 6-9/16 in. Load Knockout 13/32 in. 7-1/16 in. 6-7/8 in. 3-1/8 in. 1-1/16 in. 1-1/16 in. Line 8-7/16 in. 6 in. 3-1/2 in. Approved for copper or aluminum Cat. No. FA4B-6T w w w. t n b. c a Description Underground c/w 6 pole test switch Dimensions (in.) H D 13-5/16 8-7/16 Weight Each lb. kg 50 22.67 D39 Meter Sockets JS4 Series 400 A 120/240 V; Single Phase Service Product Specifications •Load side terminations: tunnel type connectors, dual rated for 1 x 500 kcmil or 2 x 250 kcmil •Fully wired secondary circuits •Line side terminations: double 1/2 in. studs to accommodate compression lugs (supplied by utility) for underground service (1 x 500 kcmil or 2 x 250 kcmil) •Permanent red nameplate affixed to front cover warns that removal of meter does not isolate the load terminals; also notice of automatic circuit closing device on JS4A and warning to short circuit current transformer secondary before removal of meter on JS4B •Meter socket configuration for 5 jaw meters (can be readily converted to suit meter forms requiring 4 blades) •400/5 A three-wire current transformer provides low current for service metering proportional to higher current draw. Consumer and Corporate Affairs Canada approved for revenue metering (200/5 and 300/5 A also available) •Gutter wiring space provided on left side •Twin covers allow access to either compartment (single cover available on request) •Hub opening closure plate for underground service. All units can be converted to overhead service with addition of conduit hub and JS250 or JS500 tunnel type connector kit •Hinged bridges and readily removable crossbar with keyholes permit easy wiring without obstructions •Heavy gauge galvanized steel. Ovencured grey enamel finish. •For aluminum JS4’s see page D41 for product specs and dimensions •Three 1-1/4 in., 1-1/2 in., 2 in., 2-1/2 in., 3 in., 3-1/2 in., 4 in. Bottom Knockouts •Weatherproof Type 3R enclosure (JS4B) (JS4A) KIT-400MH (see page D58) Trade Size Knockout 1, 1-1/4, 1-1/2, 2, 2-1/2, 3, 3-1/2 and 4 in. 3 Places Trade Size Knockout 1/2 in. 2 Places Additional 2-1/2 in. opening for parallel run 3-1/8 in. 3-1/8 in. 3-13/16 in. 1-1/8 in. 10-1/8 in. 5-3/4 in. 2-1/2 in. 2-1/2 in. 4 in. 1 in. 1-1/8 in. 10-1/8 in. 20-1/4 in. 3-13/16 in. Approved for copper or aluminum Product Usage by Province/Utility Newfoundland JS4B-4ST, JS4B-NL, JS4B-EALNL Saskatchewan JS4A-4TWE Northern Ontario JS4A, JS4A-4 Quebec None approved Alberta JS4B-4T Cornwall Hydro JS4A-4T Nova Scotia JS4B-STNS British Colombia JS4B-STWINL Ottawa Hydro JS4AB-TW Toronto Hydro JS4AB-300/5 New Brunswick JS4B (EAL) Hydro Ontario JS4A, JS4A-200/5, JS4A-300/5, JS4A-4, JS4A-4T, JS4B, JS4B-4 JS4B-ST, JS4AB Manitoba JS4A-4TW, JS4A-4TWEAL Hydro One JS4B-TWLHO D40 w w w.t nb.c a Meter Sockets JS4 Series 400 A 120/240 V; Single Phase Service Approved for copper or aluminum Cat. No. JS4 Underground 400 to 5 Ratio • 5 Jaw • Twin Cover JS4A JS4B Equipped with automatic circuit closing device Equipped with test switches 1 x 500 kcmil 2 x 250 kcmil UNDERGROUND SERVICE Include Factory Modifications -4 -S -T -W -Z -200 / 5 -300 / 5 4 jaw meter socket configuration Provision only for test switches (test switches supplied by power authority) Provision only for current transformer (transformer supplied by power authority) Secondary circuit wiring not included (secondary circuit wired by power authority) ”Peerless security” collar (S102WD) 200 A to 5 ratio current transformer 300 A to 5 ratio current transformer 2 x 250 kcmil with kit no. JS250 1 x 500 kcmil with kit no. JS500 Cat. No. Overhead Entry Conversion Kits (1 Kit Required per Socket) JS250 JS500 KIT-JS4B 2 x 250 kcmil tunnel connector kit for line side terminations OVERHEAD SERVICE 1 x 500 kcmil tunnel connector kit for line side terminations 5th jaw assembly kit for NB Power Note: Refer to page D40 for “Product usage by Province utility” JS4 Series – Single Phase Service Aluminum only Product Specifications • Line side terminals: Overhead: 1 x 750 kcmil Cu Al or 2 x 350 kcmil Cu Al Underground: 2 x 1/2 in. stud to accommodate, 1 x 750 kcmil or 2 x 350 kcmil Cu Al compression lugs • Load side terminals: 1 x 750 kcmil Cu or Al or 2 x 350 MCM Cu/Al • Combination overhead/underground meter socket • 4 jaws meter socket configuration JS4B-EAL (New Brunswick) Overhead Kit required (1 kit per socket) JS350 2 x 350 kcmil Overhead Kit JS750 1 x 750 kcmil Overhead Kit JS4B-4STNSEAL (Nova Scotia) JS4A-4TWEAL (Manitoba) Trade Size Knockout 1, 1-1/4, 1-1/2, 2, 2-1/2, 3, 3-1/2 and 4 in. 3 Places Trade Size Knockout 1/2 in. 2 Places 3-1/4 in. 1-1/8 in. 1-1/16 in. 1-1/8 in. 1-1/16 in. 3-3/4 in. Cat. No. Description JS4A-4TWEAL JS4B-EAL JS4B-4STNSEAL Aluminum Feed 400 A meter socket (Manitoba only) Aluminum Feed 400 A meter socket (New Brunswick only) Aluminum Feed 400 A meter socket (Nova Scotia only) w w w. t n b. c a 6-5/16 in. 6-5/16 in. Approved for copper or aluminium H Dimensions (in.) W D 38-1/8 20-1/16 8-1/4 Weight Each lb. kg 31.75 70 72 32.65 D41 Meter Sockets Typical Wiring Diagrams Reference Meter Sockets 4 Jaw 110/220 V 1Ø3 W BA3- Reference Meter Sockets 7 Jaw 3 PH 4W PL17 GR. BE1110 BQ2- PL27 A B N GR. C 110 220 BS2MO2- L2 L1 A N CO2- C B N LOAD Reference Meter Sockets BE1-5 5 Jaw 3 PH 4W GR. N BS2-5 120 BE1-6 5 Jaw 3 PH 3W BE1-5-INV A BQ2-5 BS2-6 Reference Meter Sockets C 208 L1 BS2-5-IN A B C 120 N 5TH L2 C A B 5TH NETWORK D42 w w w. t n b. c a Meter Sockets Typical Wiring Diagrams Reference Meter Sockets 4 Jaw 1PH CMS Reference Meter Sockets CT104 CL4-V 8 Jaw 3 PH 3W CT108 CT CT A L1 B N C L2 CT I E I Reference Meter Sockets E I E 13 Jaw 3 PH 3W CT113 CT CT A N B GR. C w w w. t n b. c a D43 Meter Sockets Accessories Stainless Steel Sealing Rings Cat. No. MSR-C2 Description Stainless steel sealing ring, tamper-proof MSR-C2 Polycarbonate Sealing Ring Cat. No. S102WD Description Ring, available with any meter socket When ordering any meter socket, add suffix “Z” to meter socket cat. no. to exchange standard stainless steel ring for S102WD model. S102WD Meter Protectors Product Specifications • Meter protector for use in problem areas (trailer parks, playgrounds, conservation areas) • Steel construction (16 ga. galv. steel) • Clear, unbreakable polycarbonate front cover, which allows full view of meter revenue reading and serial number • Sealing and padlocking provision • Grey painted Cat. No. MP01 / MP02 D44 MP01 MP02 Description 7-1/6 in. dia. x 4-3/4 in. deep for use with single phase residential meters 7-1/6 in. dia. x 8-3/4 in. deep for use with all meters, other than single phase residential meters w w w. t n b. c a Meter Sockets Accessories Blank Meter Cover Plates Description Cat. No. BS087 BS089 BS090 Grey ABS Plastic “throw-away” cover Clear unbreakable polycarbonate BS087 / BS089 / BS090 Jumper Bar Description Cat. No. CM-BS100 CM-BS100 200 A Max. Meter Jaw Safety Shroud Description Cat. No. LS500 Red polycarbonate, 100/200 A Mast Coupler LS500 Description Cat. No. MH200 Fits all sockets with regular 2-1/2 in. hub opening Mast Hubs MH200 B A MH10X B Cat. No. PVC Cat. No. MH10X MH12X MH15 MH20 MH25 MH30 MH35 MH40 — E991G E991H E991J E991K — — — A Hub Size (in.) B 1 1-1/4 For 2-1/2 in. regular hub opening (add hub adapter plate BS052 if used with units having 4 in. hub openings) 1-1/2 2 2-1/2 3 3-1/2 For 4 in. hub opening 4 Supplied with 4 Robertson head screws. Hub Adapter Plate Cat. No. BS052 w w w. t nb. c a BS052 Description Permits use of regular size hubs on larger hub openings D45 Meter Sockets Accessories Hub Opening Closure Plates Cat. No. Description BS051 BS054 Inside attachment for regular hub opening (i.e.: 1 in. to 2-1/2 in.) Inside attachment for larger hub opening (i.e.: 3 in. to 4 in.) Insulated Neutral Kits Cat. No. Description IN1000BA, IN1000BE, IN1000PL IN2000BS, IN2000PL 100 A Max. 200 A Max. Specify socket upon ordering. Insulated Neutral Kit Cat. No. Description IN4000JS 400 A Max. (JS4) Ground Lug On Neutral Kit Cat. No. Description GN2000 200 A Max. for BQ2, BS2 Series Micro-ID-Kit Cat. No. MINI-ID-KIT MICRO-ID-KIT Description Markers Kit Includes Plastic case Qty. Stainless steel markers of each numbers 0 thru 9 (dash + service) Stainless steel markers of each letters A thru D Stainless steel markers of each numbers 0 thru 9 Blue metal Words “SERVICE” carrying case CM-BS100 Jumper Bar 200 A Max. LS500 Meter Jaw Safety Shroud 10 10 4 10 Supplied with 4 Robertson head screws. Identification Markers Cat. No. No. 0 through No. 9 No. A through No. Z No. SERVICE Description Clipped to the upper lip of the enclosure; provides permanent customer identification. Packed and sold in polyethylene bags of 10 identical markers except “SERVICE” which has 7 individual letters Replacement + Block Assemblies Consist of thermoplastic insulators with jaws and connectors assembled for replacement of one meter socket Cat. No. Description BA3-X BS2-X-UNI MO2-X-UNI PL27-XEB Fits BA3 / BE1 Series Fits BQ2 / BS2 Series uni block Fits MO2 Series uni block Fits PL27 Series uni block Add suffix “B” to cat. no. above if mounting bridge is required D46 w w w. t n b. c a Meter Sockets Accessories Fifth Jaw Assemblies Standardcapacity 9 o’ position C205 • • • • • • • • • • • • Meter Socket Series BA3 BDC BE1 BE2 BEC BD2 BQ2 BS2 / BS2L BS4 / BSC4 CO1 CO2 CO1 Multigang Full capacity 9 o’ position Z105* Z205* • • • • • • • • • • • • Full capacity 6 o’ position CM-B106* B306*† • • • • • • Fifth Jaw Assemblies • • • * CSA not applicable † For mono blocks only Pole Mount Bracket Kit Cat. No. Description PMB200 Secures Microlectric meter socket to a wooden pole via Option 1 or 2 Conductor Range 14-2 AWG Use w/Series Option 1 Option 2 Use the two side BA3, BE1, BQ2, bracket mounting BS, CL, CO1, CO2, Use a lag bolt through holes (0.320 in. dia.) CT, MO2, PL17, 5/8 in. center keyhole to wrap around PL27, VT the pole Pole Mount Bracket Kit Suitable for any Microlectric meter socket with mounting holes 5 in. apart. Attach meter socket using one or two bracket(s). PMB200 kit comes complete with 2 brackets, 1 ground connector. Includes assembly hardware. Pole Mounting Kit Cat. No. PMBJS4 Kit Includes Support hangers 1/2 in. x 4 in. lag bolt 3/8 in. x 3 in. lag bolt 5/16 in. x 1 in. carriage bolts, nuts and lock washers Qty. 2 1 4 Pole Mounting Kit Pole Line Hardware Cat. No. Description RC729 BC301L BO506 BO508 BO510 BO512 Square washer Carriage bolt F Dia. (in.) 5/8 3/8 Oval eye bolt 5/8 G Dia. (in.) 2 1-1/2 6 8 10 12 H Dia. (in.) – 1-1/2 3 4 4 4 F G T Thick (in.) 3/16 – Weight (100 pcs) lb. kg 22 10.0 11 5.0 122 55.4 136 61.8 150 68.1 168 76.3 Std. Pkg. 400 50 F F H H G G G T RC729 w w w. t n b. c a BC301L BO Series D47 Meter Sockets Accessories Breaker Mounting Bracket Description Cat. No. Adjustable Mounting Bracket for CO2 Series to adapt to Siemens, SD and Cutler Hammer breakers CO3417M-1-FG Meter Adaptor Bracket Flexible Braid Kit Description Cat. No. CO2FB-KIT Connection wires adaptor kit for CO2 Series meter sockets for field installation. To be used with Cutler Hammer breakers Connector Kit Description Cat. No. Flexible Braid Kit BP250 Connector kit 2 x 250 kcmil Service Entrance Heads Cat. No. Trade Size Service Entrance Heads (Cast Aluminum) Rigid Conduit Connector Kit CIEFA-1/2 CIEFA-3/4 CIEFA-1 CIEFA-1 1/4 CIEFA-1 1/2 CIEFA-2 CIEFA-2 1/2 CIEFA-3 CIEFA-3 1/2 CIEFA-4 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Trade Size 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 0.610 0.750 0.875 KO Dimensions Large – 0.400 0.500 0.625 0.750 1.000 1.300 1.125 1.750 Small 0.312 0.375 0.438 Center – 0.400 0.525 1.000 1.125 Service Entrance Heads (Cast Aluminum) E.M.T. CIEFA-1/2 / CIEFA-4 CIEFSA-1/2 / CIEFSA-4 KO Configuration D48 1/2 in. 3/4 in. - 1-1/4 in. 1-1/2 in., 2 in. 2 -1/2 in., 4 in. CIEFSA-1/2 CIEFSA-3/4 CIEFSA-1 CIEFSA-1 1/4 CIEFSA-1 1/2 CIEFSA-2 CIEFSA-2 1/2 CIEFSA-3 CIEFSA-3 1/2 CIEFSA-4 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 w w w.t nb.c a Meter Sockets Meter Covers Meter Series AB BA BE1 BE2V BE3V BE4V BE5V BE6V BEC2V BEC3V BEC4V BEC5V BEC6V BP2-TV BQ2V BS2V BS2L BS4M-V MO2V PL17 PL27 BS42 BS43 BS44 BS45 BS46 BSC42V BSC43V BSC44V BSC45V BSC46V BD2V BD3V BD4V BDC2 BDC3 BDC4 w w w. t n b. c a With Meter Hole 1 X AB1021A FG 1 X BS3321 FG 1 X BS1321 FG 2 X BS1321 FG 3 X BS1321 FG 4 X BS1321 FG 5 X BS1321 FG 6 X BS1321 FG 2 X BS4321 FG 3 X BS4321 FG 4 X BS4321 FG 5 X BS4321 FG 6 X BS4321 FG 1 X PL7321 FG 1 X BS2321 FG 1 X BSC2321 FG 1 X BS8321 FG 1 X BS2321 FG 1 X PL7321 FG 2 X BS5521-FG 3 X BS5521-FG 4 X BS5521-FG 5 X BS5521-FG 6 X BS5521-FG 2 X BS5521-FG 3 X BS5521-FG 4 X BS5521-FG 5 X BS5521-FG 6 X BS5521-FG 2 X BD5421 FG 3 X BD5421 FG 4 X BD5421 FG 2 X BD5421 FG 3 X BD5421 FG 4 X BD5421 FG Without Meter Hole Meter Series CO1 CO2 CO2M Top Cover “Meter” CO2321 FG CO3322 FG CO3322 MFG Bottom Cover “Breaker” CO2023 FG CO3021 FG – Meter Series CO2MS 1 X BS4321A FG – 1 X BS5521A-FG Top CO3322 MFG Middle CO3321 MSFG Bottom CO3323 MSFG Meter Series CT104-5SWLHQ CT-L CT-SWL CT CL HD JS4 JS4 (EAL) Top Cover “Meter” CT2321FG CT1321FG CT1321FG CT1321 FG BS3321 FG HD102/A JS5321A FG JS5321A FG Bottom Cover CT2023FG CT1023FG CT1023FG CT1021AFG – HD1022A JS5221B FG JS5221B EAL Meter Series CO22 CO42 Top Cover “Meter” CO5322FG CO8342FG Bottom Cover CO8021FG C08021FG 2 X BS5521A-FG 1 X BD5421A FG 1 x BDA5521A FG D49 Meter Sockets Service Masts Service Entrance Masts and Accessories 1 2 16 3 4 17 5 8 1 in. 6 7 / 2 in 22-1 18 4-7 /8 i 9 10 3/4 c in. rw en t e a . ho ll mt . n. les 5 in . 11 19 10 in. 5 in. 12 2 in 11-1/ 1-3/8 in. 13 20 VARIOUS SERVICE ENTRANCE MAST KITS ARE AVAILABLE; PLEASE INQUIRE AT YOUR NEAREST THOMAS & BETTS SALES OFFICE. 14 15 21 22 23 Fittings for old style 2-3/4 in. outside diameter service masts. D50 w w w. t n b. c a Meter Sockets Service Masts Service Entrance Masts and Accessories Reference No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 w w w. t nb. c a Cat. No. MM104 MM105 MM202 MM380 MM380A MM101 MM5101 MM201 MM801 MM390 MM300 MM500 MM501 MM502 MM503 MM505N MM5505N MM250 MM251 MM255 MM252 MM400 MM401 MM445 MM5400 MM8 MM9CM MM10 MM12 MM600 MM601 MM602 MM602LD MM603 MM100 MM140 MM140M MM150 MM150M MM200 MM200M MH200 MH40 MM506N MM806N MM507DN MM604 MM605 MM700 MM202P CIEFA-4 MM200P MC250 lb./kg 100 pcs 105/47.1 130/59 200/90 Std. Pkg. 20 50/22.7 50 125/56 164/74 300/136 360/163 50/22.7 100/45.4 14/6.3 36/16.3 150/68 180/81 140/63 140/63 125/56 40/18.1 40/18.1 30/13.6 225/102 110/50 10 20 10 10 50 20 50 10 20 50 20 215/97 2800/1272 3300/1500 3500/1590 4200/1909 235/106 190/86 150/68 119/54 200/90 36/16.3 44/20 40/18 103/46.82 52/23.6 100/45 93/42.3 150/68 50/22.7 85/38.6 200/90 590/268 44/20 45/21 50 20 25 1 10 10 25 50 10 1 20 30 Description 1-1/4 in. Entrance cap 100 A 1-1/2 in. Entrance cap 150–200 A 2 in. Entrance cap 200 A Guy attachement c/w oval eye Guy attachement without oval eye complete with bracket Light duty spool rack 100 A Light duty spool rack (Alberta only) 100 A Heavy duty spool rack 200 A Heavy duty spool rack 400 A, fits 3 in. and 4 in. Rigid conduit Drop wire hook bracket Service mast wire holder Neoprene collar only Steel collar only Roof base flange only Roof flange C/W steel collar Roof flange C/W neoprene collar Roof flange C/W neoprene collar 1-1/4 in. 1/2 in. dia. «U» bolt mast clamp Pipe strap C/W two 3/8 in. x 4 in. lag screws Pipe strap C/W two 3/8 in. x 5 in. lag screws Pipe strap only less lag screws Support clamp C/W 5/8 in. x 10 in. fully threaded bolt and 4 in. x 4 in. square washer Clamp only less bolt and washer Support clamp C/W 5/8 in. x 4-1/2 in. fully threaded bolt and 4 in. x 4 in. square washer Support clamp C/W 1/2 in. x 10 in. bolt 8 ft. x 2-1/2 in. outside diameter mast 9 ft. x 2-1/2 in. outside diameter mast 10 ft. x 2-1/2 in. outside diameter mast 12 ft. x 2-1/2 in. outside diameter mast Meter spacer complete with pipe strap; 5/8 in. x 4-1/2 in. carriage bolt and 4 in. x 4 in. square washer Same as above except no pipe strap Spacer only (less strap, bolt and washer) (suggested for brick applications with MM201 less pipe strap) Light duty spacer only (less strap, bolt and washer) Spacer with pipe strap (less bolt and washer) 1 in. Female reducer 1-1/4 in. Female reducer 1-1/4 in. Male reducer 1-1/2 in. Female reducer 1-1/2 in. Male reducer 2 in. Female reducer 2 in. Male reducer 2 in. Mast adaptor 4 in. Mast coupler Simple all neoprene roof flange, 200 A, for 2-1/2 in. masts Simple all neoprene roof flange, 400 A, for 4 in. masts Double all neoprene roof flange; for 2-1/2 in. masts Meter socket bracket (Dimensions see page D50) Meter socket mounting bracket (Dimensions see page D50) Service mast ground clamp, wire range: 8-1/0 AWG 2 in. entrance cap for old style 2-3/4 in. service masts 4 in. entrance head 2 in. female reducer for old style 2-3/4 in. service masts 2-1/2 in. one-piece coupler (check the installation standards in your region before using the product) D51 Meter Sockets Service Masts Guy Kits for 2-1/2 in. Masts MM914 MM9516 Cat. No. Qty. Consists of Description MM380 GT516 GE14 GW14110 GC902 RB404 T404-CM Mast Guy Attachment Guy Thimbles Guy End 20 ft. of 1/4 in. Guy Wire Guy Clamp Roof Bracket Lag Screw MM380 GT516 GE516 GW516110 GC902 BTE512 RA725 Mast Guy Attachment Guy Thimble Guy End 20 ft. of 5/16 in. Guy Wire Guy Clamp 5/8 in. x 12 in. Bent Thimble Eye Bolt Round Washer 1/4 in. Guy Kit 1 2 MM914 1 5/16 in. Guy Kit MM9516 D52 1 w w w. t n b. c a Meter Sockets Service Masts Mast Kits Suitable for British Columbia Cat. No. Qty. 1 KIT-100BCMH 3 1 KIT-100BCMN 3 1 MMK1-NMH 3 1 KIT-200BCMH 3 1 MMK2-NMH 3 1 w w w. t n b. c a Consists of MM104 MM101 MM505N MM250 MH200 MM104 MM101 MM505N MM250 MM140 MM104 MM101 MM505N MM400 MH200 MM202 MM201 MM505N MM250 MH200 MM202 MM201 MM505N MM400 MH200 Description Entrance Cap Light Duty Rack Flange c/w Neoprene Collar “U” Bolt Clamp Mast Coupler Entrance Cap Light Duty Rack Flange c/w Neoprene Collar “U” Bolt Clamp 1-1/4 in. Female Reducer Entrance Cap Light Duty Rack Flange c/w Neoprene Collar Support Clamp Mast Coupler Entrance Cap Heavy Duty Rack Flange c/w Neoprene Collar “U” Bolt Clamp Mast Coupler Entrance Cap Heavy Duty Rack Flange c/w Neoprene Collar Support Clamp Mast Coupler D53 Meter Sockets Service Masts Mast Kits Suitable for Alberta KIT-1 1/4 – 100 A Cat. No. Qty. Consists of Description This mast kit is used in conjunction with 1-1/4 in. rigid conduit KIT-1 1/4 KIT-1 1/4 1 MM5104A MM5101 MM5505N MM5400 1-1/4 in. Throat Entrance Cap Light Duty Spool Rack Roof Flange c/w Neoprene Collar Support Clamp c/w 1/2 in. x 10 in. Bolt Consists of Description KIT2-CM – 100 A Cat. No. Qty. This mast kit is used in conjunction with 2 in. rigid conduit 1 KIT2-CM 2 1 MM5104B MM5101 MM505N MM5400 MM5140 2 in. Throat Entrance Cap Light Duty Spool Rack Roof Flange c/w Neoprene Collar Support Clamp c/w 1/2 in. x 10 in. Bolt 1-1/4 in. Bottom Female Reducer Consists of MM202 MM5101 MM505N MM5400 MM200M Description Entrance Cap Light Duty Spool Rack Roof Flange c/w Neoprene Collar Support Clamp c/w 1/2 in. x 10 in. Bolt 2 in. Reducer Consists of MM104 MM201 MM505N Description 1-1/4 in. Entrance Cap Heavy Duty Spool Rack Roof Flange c/w Neoprene Collar Support Clamp c/w 5/8 in. x 10 in. Fully Threaded Bolt and 4 x 4 Washer 1-1/4 in. Female Reducer KIT-2-AL – 200 A KIT2-CM Cat. No. Qty. 1 KIT-2-AL 2 1 MB-110 – 100 A Cat. No. Qty. KIT-2-AL 1 MB-110 3 MM400 1 MM140 MB-110 D54 w w w. t n b. c a Meter Sockets Service Masts Mast Kits Suitable for Manitoba and Saskatchewan Cat. No. Qty. 1 KIT-100MJ 2 1 KIT-100MN 1 3 1 KIT-100MH 3 1 KIT-200AM 1 3 1 KIT-200MH 3 1 KIT-200MJ KIT-200MNF 1 1 3 1 MMK2-NMH 3 1 w w w. t n b. c a Consists of MM104 MM140M MM101 MM505N MM251 MM400 MM104 MM140M MM101 MM505N MM255 MM104 MM101 MM505N MM251 MH200 MM202 MM201 MM200M MM505N MM255 MM202 MM201 MM505N MM255 MH200 MM202 MM200M MM201 MM505N MM251 MM400 MM202 MM201 MM200M MM251 MM202 MM201 MM505N MM400 MH200 Description Entrance Cap 1-1/4 in. Reducer Light Duty Rack Flange c/w Neoprene Collar Strap c/w 3/8 in. x 4 in. Lag Bolt Support Clamp Entrance Cap 1-1/4 in. Reducer Light Duty Rack Flange c/w Neoprene Collar Strap c/w 3/8 in. x 5 in. Lag Bolt Entrance Cap Light Duty Rack Flange c/w Neoprene Collar Strap c/w 3/8 in. x 4 in. Lag Bolt Mast Coupler Entrance Cap Heavy Duty Rack 2 in. Male Reducer Flange c/w Neoprene Collar Strap c/w 3/8 in. x 5 in. Lag Bolt Entrance Cap Heavy Duty Rack Flange c/w Neoprene Collar Strap c/w 3/8 in. x 5 in. Lag Bolt Mast Coupler Entrance Cap 2 in. Male Reducer Heavy Duty Rack Flange c/w Neoprene Collar Strap c/w 3/8 in. x 4 in. Lag Bolt Support Clamp Entrance Cap Heavy Duty Rack 2 in. Male Reducer Strap c/w 3/8 in. x 4 in. Lag Bolt Entrance Cap Heavy Duty Rack Flange c/w Neoprene Collar Support Clamp Mast Coupler D55 Meter Sockets Service Masts Mast Kits Suitable for Ontario Cat. No. KIT-100HDM Qty. 1 3 1 KIT-100MH 3 1 KIT-100MN 1 3 KIT-100NMH MMK1 1 1 3 1 MMK-1N 3 1 1 MMK1-NMH 3 1 KIT-200MH 1 3 1 KIT-200AM 3 1 D56 Consists of MM104 MM140M MM201 MM503 MM255 MM104 MM101 MM505N MM251 MM200 MM104 MM140M MM101 MM505N MM255 MM104 MM101 MM505N MM400 MM200 MM104 MM101 MM140M MM503 MM400 MM104 MM101 MM505N MM400 MM140M MM104 MM101 MM505N MM400 MH200 MM202 MM201 MM200M MM505N MM255 MM202 MM201 MM505N MM255 MH200 Description Entrance Cap 1-1/4 in. Male Reducer Heavy Duty Rack Flange c/w Steel Collar Strap c/w 3/8 in. x 5 in. Lag Bolts Entrance Cap Light Duty Rack Flange c/w Neoprene Collar Strap c/w 3/8 in. x 4 in. Lag Bolt Female Reducer Entrance Cap 1-1/4 in. Male Reducer Light Duty Rack Flange c/w Neoprene Collar Strap c/w 3/8 in. x 5 in. Lag Bolt Entrance Cap Light Duty Rack Flange c/w Neoprene Collar Support Clamp Female Reducer Entrance Cap Light Duty Rack 1-1/4 in. Male Reducer Flange c/w Steel Collar Support Clamp Entrance Cap Light Duty Rack Flange c/w Neoprene Collar Support Clamp 1-1/4 in. Male Reducer Entrance Cap Light Duty Rack Flange c/w Neoprene Collar Support Clamp Mast Coupler Entrance Cap Heavy Duty Rack 2 in. Male Reducer Flange c/w Neoprene Collar Strap c/w 3/8 in. x 5 in. Lag Bolt Entrance Cap Heavy Duty Rack Flange c/w Neoprene Collar Strap c/w 3/8 in. x 5 in. Lag Bolt Mast Coupler Cat. No. Qty. 1 KIT-200NMH 3 1 MMK2 1 3 1 MMK-2N 3 1 1 MMK2-NMH 3 1 Consists of MM202 MM201 MM505N MM400 MM200 MM202 MM201 MM200M MM503 MM400 MM202 MM201 MM505N MM400 MM200M MM202 MM201 MM505N MM400 MH200 Description Entrance Cap Heavy Duty Rack Flange c/w Neoprene Collar Support Clamp Female Reducer Entrance Cap Heavy Duty Rack 2 in. Male Reducer Flange c/w Steel Collar Support Clamp Entrance Cap Heavy Duty Rack Flange c/w Neoprene Collar Support Clamp 2 in. Male Reducer Entrance Cap Heavy Duty Rack Flange c/w Neoprene Collar Support Clamp Mast Coupler w w w. t n b. c a Meter Sockets Service Masts Mast Kits Suitable for Quebec Cat. No. KIT-100MN Qty. 1 3 1 KIT-100MH 3 1 KIT-100MNF 1 3 1 KIT-150AM 3 1 KIT-200AM 1 3 1 KIT-200AMGR 3 1 1 KIT-200MH 3 1 KIT-200MNF 3 w w w. t n b. c a Consists of MM104 MM140M MM101 MM505N MM255 MM104 MM101 MM505N MM251 MH200 Description Entrance Cap 1-1/4 in. Male Reducer Light Duty Rack Flange c/w Neoprene Collar Strap c/w 3/8 in. x 5 in. Lag Bolts Entrance Cap Light Duty Rack Flange c/w Neoprene Collar Strap c/w 3/8 in. x 4 in. Lag Bolts Mast Coupler MM104 Entrance Cap MM140M MM101 MM251 MM105 MM201 MM505N MM251 MM150M MM202 MM201 MM200M MM505N MM255 MM202 MM201 MM200M MM505N MM255 MM700 MM202 MM201 MM505N MM255 MH200 MM202 MM201 MM200M MM251 1-1/4 in. Male Reducer Light Duty Rack Strap c/w 3/8 in. x 4 in. Lag Bolts 1-1/2 in. Entrance Cap Heavy Duty Rack Flange c/w Neoprene Collar Strap c/w 3/8 in. x 4 in. Lag Bolts 1-1/2 in. Male Adaptor Entrance Cap Heavy Duty Rack 2 in. Male Reducer Flange c/w Neoprene Collar Strap c/w 3/8 in. x 5 in. Lag Bolts Entrance Cap Heavy Duty Rack 2 in. Male Reducer Flange c/w Neoprene Collar Strap c/w 3/8 in. x 5 in. Lag Bolts Service Mast Ground Clamp Entrance Cap Heavy Duty Rack Flange c/w Neoprene Collar Strap c/w 3/8 in. x 5 in. Lag Bolts Mast Coupler Entrance Cap Heavy Duty Rack 2 in. Male Reducer Strap c/w 3/8 in. x 4 in. Lag Bolts Cat. No. KIT-100HDM Qty. 1 3 1 3 1 KIT-200-PVC 2 1 1 KIT-200AM-CP 3 2 1 1 KIT-200MH-CP 3 2 1 Consists of MM104 MM140M MM201 MM503 Description Entrance Cap 1-1/4 in. Male Reducer Heavy Duty Rack Flange c/w Steel Collar MM255 Strap c/w 3/8 in. x 5 in. Lag Bolts SS401-E E998J E997JC PH20 E943J CI1716 E986J CIDUCT1 UA9AJCB-UPC MM202 MM201 MM505N MM200M MM251 E943J CI1716 E986J DUCT SEAL Spool Rack 2 in. Entrance Cap 2 in. Strap 2 in. Hub PVC 2 in. Male Adaptor 2 in. Locknut 2 in. LB Type Duct Seal 2 in. PVC Elbow 2 in. Entrance Cap Spool Rack Floor Flange 2 in. Male Reducer Strap c/w 3/8 in. x 4 in. Lag Bolts 2 in. Male Adaptor 2 in. Locknut 2 in. Entrance Cap Duct Seal UA9AJCB-UPC 2 in. PVC Elbow MM202 MM201 MM505N MH200 MM251 E943J CI1716 E986J CIDUCT1 UA9AJCB-UPC 2 in. Entrance Cap Spool Rack Roof Flange 2 in. Mast Coupler Strap c/w 3/8 in. x 4 in. Lag Bolts 2 in. Male Adaptor 2 in. Locknut 2 in. Entrance Cap Duct Seal 2 in. PVC Elbow D57 Meter Sockets Service Masts Mast Kits Suitable for Quebec and for all Regions KIT-200-PVC – Quebec Cat. No. Qty. Consists of Description This mast kit is used in conjunction with 1-1/4 in. rigid conduit 1 3 1 KIT-200-PVC 2 1 SS401-E E998J E997JC PH20 E943J CI1716 E986J CIDUCT1 UA9AJCB-UPC Spool Rack 2 in. Entrance Cap 2 in. Strap 2 in. Hub PVC 2 in. Male Adaptor 2 in. Locknut 2 in. LB Type Duct Seal 2 in. PVC Elbow Consists of Description KIT-200AM-CP – Quebec Cat. No. Qty. This mast kit is used in conjunction with 2 in. rigid conduit 1 3 KIT-200AM-CP 2 1 MM202 MM201 MM505N MM200M MM251 E943J CI1716 E986J CIDUCT1 UA9AJCB-UPC 2 in. Entrance Cap Spool Rack Roof Flange 2 in. Male Reducer 2 in. Pipe Strap (c/w Lag Screws) 2 in. Male Adaptor 2 in. Locknut 2 in. Entrance Cap Duct Seal 2 in. PVC Elbow Consists of MM202 MM201 MM505N MH200 MM251 E943J CI1716 E986J CIDUCT1 UA9AJCB-UPC Description 2 in. Entrance Cap Spool Rack Roof Flange 2 in. Mast Coupler 2 in. Pipe Strap c/w Lag Screws 3/8 x 4 in. 2 in. Male Adaptor 2 in. Locknut 2 in. Entrance Cap Duct Seal 2 in. PVC Elbow Consists of Description KIT-200MH-CP – Quebec Cat. No. KIT-200MH-CP Qty. 1 1 1 1 3 2 2 1 1 1 KIT-400MH – For all Regions Cat. No. Qty. This mast kit is used in conjunction with 4 in. rigid conduit KIT-400MH D58 1 1 1 1 3 CIEFA-4 MM801 MM806N MH40 CI1532 4 in. Entrance Head Heavy Duty Spool Rack Roof Flange 4 in. Mast Coupler Pipe Strap c/w Lag Screws (6) 3/8 x 5 in. w w w. t n b. c a Meter Sockets Service Masts Mast Kits Suitable for New Brunswick, Nova Scotia, Newfoundland and Prince Edward Island New Brunswick Cat. No. Qty. 1 1 3 1 1 3 1 1 1 1 3 1 1 1 1 3 1 1 1 3 1 1 1 3 1 1 1 3 1 KIT-100 KIT-100NBMH KIT-200 KIT-200MH KIT-206NBMH KIT-200NBMH KIT-106NBMH Nova Scotia Consists of MM104 MM140M MM251 MM505N MM104 MM251 MH200 MM505N MM202 MM200M MM251 MM505N MM202 MM201 MH200 MM255 MM505N MM202 MH200 MM251 MM506N MM202 MH200 MM251 MM505N MM104 MM506N MM251 MH200 Description Entrance Cap 1-1/4 in. Male Reducer Strap c/w 3/8 in. x 4 in. Lag Bolts Flange c/w Neoprene Collar Entrance Cap Strap c/w 3/8 in. x 4 in. Lag Bolts Mast Coupler Flange c/w Neoprene Collar Entrance Cap 2 in. Male Reducer Strap c/w 3/8 in. x 4 in. Lag Bolts Flange c/w Neoprene Collar Entrance Cap Heavy Duty Spool Rack Mast Coupler Strap c/w 3/8 in. x 5 in. Lag Bolts Flange c/w Neoprene Collar Entrance Cap Mast Coupler Strap c/w 3/8 in. x 4 in. Lag Bolts All Neoprene Roof Flange Entrance Cap Mast Coupler Strap c/w 3/8 in. x 4 in. Lag Bolts Flange c/w Neoprene Collar Entrance Cap All Neoprene Roof Flange Strap c/w 3/8 in. x 4 in. Lag Bolts Mast Coupler Cat. No. KIT-100MN KIT-100 KIT-100NSMH KIT-200AM KIT-200 KIT-200NSMH Cat. No. KIT-100MH KIT-100NBMH KIT-205LDMH Qty. 1 1 1 3 1 1 3 1 1 1 1 3 1 1 Consists of MH200 MM104 MM101 MM251 MM505N MM104 MM251 MH200 MM505N MM202 MM101 MM251 MH200 MM505N Description Mast Coupler Entrance Cap Light Duty Spool Rack Strap c/w 3/8 in. x 4 in. Lag Bolts Flange c/w Neoprene Collar Entrance Cap Strap c/w 3/8 in. x 4 in. Lag Bolts Mast Coupler Flange c/w Neoprene Collar Entrance Cap Light Duty Spool Rack Strap c/w 3/8 in. x 4 in. Lag Bolts Mast Coupler Flange c/w Neoprene Collar KIT-100MH Qty. 1 1 3 1 1 1 KIT-106NBMH KIT-200MH KIT-200NBMH KIT-206NBMH w w w. t n b. c a 1 1 1 3 1 1 1 3 1 1 4 1 1 1 1 3 1 1 1 1 3 1 1 1 3 1 Consists of MM104 MM140M MM101 MM255 MM505N MM104 MM140M MM251 MM505N MM104 MM251 MM505N MH200 MM202 MM201 MM255 MM200M MM505N MM202 MM200M MM251 MM505N MM202 MH200 MM251 MM505N Description Entrance Cap 1-1/4 in. Male Reducer Light Duty Spool Rack Strap c/w 3/8 in. x 5 in. Lag Bolts Flange c/w Neoprene Collar Entrance Cap 1-1/4 in. Male Reducer Strap c/w 3/8 in. x 4 in. Lag Bolts Flange c/w Neoprene Collar Entrance Cap Strap c/w 3/8 in. x 4 in. Lag Bolts Flange c/w Neoprene Collar Mast Coupler Entrance Cap Heavy Duty Spool Rack Strap c/w 3/8 in. x 5 in. Lag Bolts 2 in. Male Reducer Flange c/w Neoprene Collar Entrance Cap 2 in. Male Reducer Strap c/w 3/8 in. x 4 in. Lag Bolts Flange c/w Neoprene Collar Entrance Cap Mast Coupler Strap c/w 3/8 in. x 4 in. Lag Bolts Flange c/w Neoprene Collar Prince Edward Island Newfoundland Cat. No. Qty. 3 1 1 1 1 1 3 1 1 1 3 1 1 1 3 1 Consists of MM104 MM101 MM251 MM505N MH200 MM104 MM251 MH200 MM506N MM202 MM201 MH200 MM255 MM505N MM202 MH200 MM251 MM505N MM202 MH200 MM251 MM506N Description Entrance Cap Light Duty Spool Rack Strap c/w 3/8 in. x 4 in. Lag Bolts Flange c/w Neoprene Collar Mast Coupler Entrance Cap Strap c/w 3/8 in. x 4 in. Lag Bolts Mast Coupler All Neoprene Roof Flange Entrance Cap Heavy Duty Spool Rack Mast Coupler Strap c/w 3/8 in. x 5 in. Lag Bolts Flange c/w Neoprene Collar Entrance Cap Mast Coupler Strap c/w 3/8 in. x 4 in. Lag Bolts Flange c/w Neoprene Collar Entrance Cap Mast Coupler Strap c/w 3/8 in. x 4 in. Lag Bolts All Neoprene Roof Flange D59 Meter Sockets Pole Line Hardware Heavy-Duty Spool Rack (200 A) Cat. No. No. of Wires Overall Length (in.) SS401E SS802E SS803E SS804E 1 2 3 4 9-1/2 17-1/2 25-1/2 33-1/2 Weight (100 pcs) lb. kg 300 136.3 520 236.3 780 354.5 1040 472.7 Std. Pkg. 10 5 Racks are made of 1 in. x 1 in. x 1/8 in. angle iron, assembled complete with 5/8 in. diameter rod and 3/16 in. diameter brass cotter pin. All ferrous parts are hot dip galvanized. Insulator cat. no. IB135 must be ordered separately (included in SS401E only). SS401E - SS802E - SS803E - SS804E Heavy-Duty Spool Rack (400 A) Cat. No. No. of Wires Overall Length (in.) MM801 1 3 Weight (100 pcs) lb. kg 360 163.2 Std. Pkg. 10 MM801 Medium-Duty Spool Rack (100 A) Cat. No. SS18 No. of Wires Overall Length (in.) 1 6-1/2 Weight (100 pcs) lb. kg 150 68.1 Std. Pkg. 25 Medium duty spool rack is furnished complete with cat. no. IB134 insulator. All ferrous parts are hot dip galvanized. SS18 Tripods (200 A) 96 in. Cat. No. No. of Wires 603TH* 604TH 3 — Weight (100 pcs) lb. kg 4000 1818.1 3800 1727.2 Std. Pkg. 1 1 Type “T” (medium duty) is constructed of 1 in. x 1 in. x 1/8 in. angle iron. Type “TH” (heavy duty) is constructed of 1-1/4 in. x 1-1/4 in. x 3/16 in. angle iron. All ferrous parts are hot dip galvanized. * Complete with IB400. 72 in. 24 in. 603TH-604TH D60 w w w. t n b. c a Meter Sockets Pole Line Hardware Tripod insulator (200 A) Cat. No. Height (in.) Overall Dia. (in.) IB400 3-1/2 3-1/4 Weight (100 pcs) lb. kg 125 56.8 Std. Pkg. 25 IB400 Insulators (100–200 A) Cat. No. IB134 (100 A) IB135 (200 A) Height (in.) 2 3 Ampere 100 200 Diameter (in.) 2-1/4 3 Weight (100 pcs) lb. kg 40 18.1 115 52.2 Hole Dia. (in.) 9/16 13/16 Std. Pkg. 100 50 Porcelain insulator securely held in the hot galvanized steel clevis by a cotter pin. IB134 - IB135 Screw type insulator (100 A) Cat. No. IB900 Insulator Length (in.) 3 Pull Out Strength 1500 lb. Weight (100 pcs) lb. kg 87 39.5 Std. Pkg. 25 Porcelain insulator securely held in the hot galvanized steel clevis by a cotter pin. IB900 Light-Duty Clevis (100 A) 2-1/8 in. Cat. No. 2-1/8 in. AN422 AN422KIT AN423 Weight (100 pcs) lb. kg Mounting Hole Std. Pkg. 11/16 in. round 90 40.9 11/16 in. round c/w bolts and washers – – 25 1 9/16 in. x 9/16 in. square 90 40.9 25 Add suffix “NI” if insulator is not required. Constructed of 1/8 in. x 1 in. flat mild steel, has 3/8 in. diam. pin and C/W No. IB134 insulator, mounting hole as per table above. All ferrous parts are hot dip galvanized. AN422 - AN422KIT - AN423 Clevis (200 A) 2-5/8 in. Cat. No. AN424 2-1/8 in. Weight (100 pcs) lb. 100 kg 45.4 Std. Pkg. 25 Add suffix “NI” if insulator is not required. Constructed of 1/8 in. x 1-1/4 in. flat mild steel, has 3/8 in. diam. pin and C/W No. IB134 insulator, 3/8 in. round mounting hole. All ferrous parts are hot dip galvanized. AN424 w w w. t n b. c a D61 Meter Sockets Pole Line Hardware Heavy-Duty Clevis (200 A) 4 in. Cat. No. AN428S 3-1/4 in. Weight (100 pcs) lb. 262 kg 119 Std. Pkg. 25 Add suffix “NI” if insulator is not required. Constructed of 3/16 in. x 1-1/2 in. flat mild steel, has 5/8 in. diam. pin and C/W No. IB135 insulator, 11/16 in. round mounting hole. All ferrous parts are hot dip galvanized. AN428S Heavy-Duty Clevis (200 A) 4 in. Cat. No. AN428 3-1/4 in. Weight (100 pcs) lb. kg 350 159 Std. Pkg. 5 Add suffix “NI” if insulator is not required. Constructed of 1/4 in. x 2 in. flat mild steel, has 5/8 in. diam. pin and C/W No. IB135 insulator, 11/16 in. round mounting hole. All ferrous parts are hot dip galvanized. AN428 Heavy-Duty Flat Mount Triplex Cable Rack (200 A) Cat. No. AN117 3-1/4 in. Weight (100 pcs) lb. 290 kg 130 Std. Pkg. 10 Heavy duty wall rack constructed of 1/8 in. steel, C/W 2 mounting holes 1/2 in., C/W No. IB135 insulator. All ferrous parts are hot dip galvanized. AN117 Light-Duty Flat Mount Triplex Cable Rack (100 A) Cat. No. AN122 2-1/2 in. Weight (100 pcs) lb. 160 kg 70 Std. Pkg. 10 Light duty wall rack constructed of 1/8 in. steel, C/W 2 mounting holes 1/2 in., C/W No. IB134 insulator. All ferrous parts are hot dip galvanized. AN122 D62 w w w. t n b. c a Meter Sockets Pole Line Hardware Clevis (100 A) Cat. No. AL425 2-1/8 in. Weight (100 pcs) lb. 162 kg 73.6 Std. Pkg. 20 Add suffix “NI” if insulator is not required. Constructed of 3/16 in. x 1-1/2in. flat mild steel, has 1/2” diam. pin and C/W No. IB134 insulator, 11/16 in. round mounting hole. All ferrous parts are hot dip galvanized. 4-3/16 in. AL425 Clevis (200 A) Cat. No. AL426 3-1/4 in. Weight (100 pcs) lb. 262 kg 119 Std. Pkg. 10 Add suffix “NI” if insulator is not required. Constructed of 3/16 in. x 1-1/2 in. flat mild steel, has 5/8 in. diam. pin and C/W No. IB135 insulator, 11/16 in. round mounting hole. All ferrous parts are hot dip galvanized. 4-3/16 in. AL426 Clevis (200 A) Cat. No. AU427 3-1/4 in. Weight (100 pcs) lb. 265 kg 120.4 Std. Pkg. 10 Add suffix “NI” if insulator is not required. Constructed of 1-1/4 in. x 1/2 in. x 1/8 in. steel channel, has 5/8 in. diam. pin and C/W No. IB135 insulator, 11/16 in. round mounting hole. All ferrous parts are hot dip galvanized. 3-3/4 in. AU427 Clevis (200 A) Cat. No. AU429 3-1/4 in. Weight (100 pcs) lb. 240 kg 109 Std. Pkg. 10 Add suffix “NI” if insulator is not required. Constructed of 1 in. x 1/2 in. x 1/8 in. steel channel, has 5/8 in. diam. pin C/W No. IB135 insulator, 11/16 in. square hole. All ferrous parts are hot dip galvanized. 3-3/4 in. AU429 w w w. t n b. c a D63 Meter Sockets Pole Line Hardware Clevis (100 A) Cat. No. SW409 2-1/4 in. Weight (100 pcs) lb. 100 kg 45.4 Std. Pkg. 25 Add suffix “NI” if insulator is not required. Constructed of 1/8 in. x 1 in. curved mild steel, has 3/8 in. diam. swivel type pin C/W No. IB134 insulator, 2 mtg. holes 7/16 in. round. All ferrous parts are hot dip galvanized. SW409 Clevis (100 A) 10 in. Cat. No. SW410 6 in. Weight (100 pcs) lb. 180 kg 81.8 Std. Pkg. 20 Add suffix “NI” if insulator is not required. Undereave/off the wall bracket constructed of 3/16 in. x 1-1/2 in. flat mild steel, C/W No. IB132 insulator. Three 3/8 in. round mtg. holes. All ferrous parts are hot dip galvanized. 4 in. SW410 Clevis (100 A) Cat. No. 2 in. SW411 2-1/4 in. Weight (100 pcs) lb. 125 kg 56.8 Std. Pkg. 20 Add suffix “NI” if insulator is not required. Constructed of 1/8 in. x 3/4 in. curved mild steel, has 3/8 in. diam. swivel type pin C/W No. IB134 insulator, strong 1/4 in. angle bracket, 11/16 in. round mtg. hole. All ferrous parts are hot dip galvanized. 2-1/2 in. SW411 Clevis (100 A) Cat. No. SW411S 4-1/2 in. 2-1/4 in. Weight (100 pcs) lb. 125 kg 56.8 Std. Pkg. 20 Add suffix “NI” if insulator is not required. Constructed of 1/8 in. x 3/4 in. curved mild steel, has 3/8 in. diam. swivel type pin C/W No. IB134 insulator, strong 1/4 in. bracket, 11/16 in. round mtg. hole. All ferrous parts are hot dip galvanized. SW411S D64 w w w. t n b. c a Meter Sockets Pole Line Hardware Clevis (100 A) Weight (100 pcs) Cat. No. lb. 100 SW412 Std. Pkg. kg 45.4 10 Add suffix “NI” if insulator is not required. Undereave/off the wall bracket constructed of 3/16 in. x 1-1/2 in. steel, C/W No. IB134 insulator. Three 3/8 in. round mtg. holes. All ferrous parts are hot dip galvanized. SW412 Clevis (100 A) Weight (100 pcs) Cat. No. lb. 140 SW412-MH Std. Pkg. kg 63.5 20 Add suffix “NI” if insulator is not required. Constructed of 3/16 in. x 1-1/2 in. steel, has 5/8 in. diam. pin and C/W No. IB134 insulator. 11/16 in. round mtg. hole. All ferrous parts are hot dip galvanized. SW412-MH Anti-Vibration Kit for Spool Rack Weight (100 pcs) lb. kg Cat. No. Description B3/8-6 2 bolts 3/8 x 6 in. long c/w 1 washer, 1 lockwasher and 1 nut finished hot galv. 100 45.35 Std. Pkg. 5 Add suffix “NI” if insulator is not required. Constructed of 1-1/4 in. x 1/2 in. x 1/8 in. steel channel, has 5/8 in. diam. pin and C/W No. IB135 insulator, 11/16 in. round mounting hole. All ferrous parts are hot dip galvanized. Québec Construction Code, Chapter V – Electricity, Article 6-112 (6) requires that the spool rack be tightly bolted and attached to structural members of a minimum thickness of 88mm overall, if the framed structure is made of wood. PLAN VIEW ELEVATION VIEW Minimum 38 mm Hydro-Québec, Low-Voltage Electrical Service, Standard E21-10, Article 2.2.1, 2.2.2 and Blue Book read as follows: Bolt (mandatory) Minimum 38 mm Lag screw (prohibited) Note: Interior insulation and exterior wall are not shown for more clarity. Figure 2: Spool rack installation (wooden structure). Source: Régie du bâtiment du Québec. Can also be used in all Provinces w w w. t n b. c a 2.2.1 SUPPLY AND INSTALLATION The master electrician shall, at the customer’s expense, supply and install the spool rack in accordance with Code requir ments and with the recommendations of the Régie du bâtiment du Québec, particularly to avoid any problem due to vibrations. The customer retains ownership of the spool rack. 2.2.2 LOCATION The spool rack may be attached to the exterior wall of a building or to a customer pole, service mast or other support structure. The master electrician shall ensure that the service loop is secured firmly to the building in a location not conducive to vibrations, and shall strengthen the structure, if necessary, at the customer’s expense. The location must also allow the meter to be installed in a readily accessible place. D65 Meter Sockets Pole Line Hardware Machine Bolts Cat. No. F F H G BM506 BM508 BM510 BM512 BM514 BM516 BM518 BM520 F Diam. (po) G Long. (po) H Min. (po) 6 1-1/2 8 4 10 5/8 Weight (100 pcs) lb. kg Std. Pkg. 70 31.8 86 39.0 102 46.3 12 115 52.2 14 130 59.0 145 65.9 18 160 72.7 20 175 79.5 16 6 25 50 Lag Screws Cat. No. T102L T103 T203 T302 T303 T304 T305 T306 T308 T310 T404-CM T405 T406 T505 D66 F Diam. (po) 1/4 5/16 3/8 G Long. (po) 2-1/2 Weight (100 pcs) lb. kg 3 1.3 4 1.8 6 2.7 2 7 3.1 3 10 4.5 4 11 5.0 5 14 6.3 6 17 7.7 3 Std. Pkg. 8 22 10.0 10 27 12.2 4 22 10.0 1/2 5 27 12.2 6 31 14.0 5/8 5 45 20.4 100 50 25 10 50 25 w w w. t n b. c a Meter Sockets Pole Line Hardware “U” Cable Guards and Straps Cat. No. Width (in.) Length (ft.) Weight (100 pcs) lb. kg Size Std. Pkg. Straight UG8114 UG8214 UG8314 Flared UGF8114 UGF8214 UGF8314 Strap SUG114 SUG214 SUG314 L 1-1/4 2-1/4 3-1/4 8 – 760 1300 2000 345 590 909 5 1-1/4 2-1/4 3-1/4 8 – 760 1300 2000 345 590 909 5 – – 1-1/4 2-1/4 3-1/4 15 24 60 6.8 11.0 27.0 10 Hot dip galvanized 14 gauge steel. For nonmetallic version (PV-Mold™), refer to pp. D73–D77. W Guy Clamps Cat. No. GC902 GC904 GC906 Bolt Qty. 2 3 Size 1/2 5/8 Length (in.) 3-1/4 5-7/8 6 Range (in.) 1/4–7/16 5/16–1/2 Weight (100 pcs) lb. kg 130 59.0 224 101.3 274 124.5 Std. Pkg 50 25 Eye Nut Cat. No. Eye Dimensions (in.) Weight (100 pcs) lb. kg K58 1-5/16 x 1-11/16 70 31.8 Std. Pkg. 50 3-1/2 in. 9/16 in. 1-1/4 in. 1-5/16 in. 1-11/16 in. Drop forged, hot galvanized, tapped 5/8 in. 2-7/16 in. w w w. t n b. c a 1-1/4 in. D67 Meter Sockets Pole Line Hardware Guy Hooks Weight (100 pcs) lb. kg Cat. No. Bolt Size (in.) CH912 K133A 5/8 90 40.9 50 5/8–3/4 118 53.6 25 CH912 K133A Std. Pkg. Prevent the guy from slipping down, when the pole is guyed at a sharp angle. Made of half oval steel, the round side serving as protection to the strands. Iron guy hook for use with 5/8 in. or 3/4 in. bolt. Equipped with teeth to imbed in the wood fibres. K133A Screw Anchor Cat. No. Rod Dia. (in.) Length (ft.) Plate Dia. (in.) TS346 3/4 5.6 6 Weight (100 pcs) lb. kg 1050 Std. Pkg. 477.2 2 Installed by placing a rod into the heavy forged oval eye to screw the anchor into the ground. TS346 Anchor Rods Cat. No. Rod Dia. (in.) Length (ft.) AR586 AR347 5/8 6 3/4 7 Type Double thimble Weight (100 pcs) lb. kg 750 340.9 1320 600.0 Std. Pkg. 5 AR586 - AR347 Expanding Anchor Cat. No. EA08 Hole Size (in.) Required Area (sq. in.) Rod Dia. (in.) 8 135 5/8 - 3/4 Weight (100 pcs) lb. kg 950 431.8 Std. Pkg. 5 These heavy duty steel anchors have 8 blades that expand to form a square, with equalized load distribution all around the anchor. EA08 D68 w w w. t n b. c a Meter Sockets Pole Line Hardware Oval Eye Bolt Cat. No. Description H BO506 BO508 BO510 BO512 G BO506-508-510-512 Oval eye bolt F Dia. (in.) G Length (in.) H Min. (in.) 6 3 8 5/8 10 4 12 Weight (100 pcs) lb. kg Std. Pkg. 122 55.4 50 136 61.8 25 150 68.1 25 168 76.3 25 W Guy Strain Insulator Note: Made of Porcelain L Cat. No. Length (ft.) 504WGS 506WGS Dia. (in.) 4-1/4 2-7/8 5-1/2 3-3/8 Weight (100 pcs) lb. kg 1.0 Std. Pkg. 0.45 1 504WGS-506WGS Guy Wire Guard Cat. No. Colour Length (ft.) 2YG Yellow 6.7 Weight (100 pcs) lb. kg 3.35 1.46 Std. Pkg. 10 2YG Type W – Aluminum Service Wedge Clamps for use with ACSR, Aluminum, AAAC Conductors • For dead-ending self-supporting drop wire • Saves conductor – drop wire may be cut to exact length • Can be attached to bare neutral at any point in the span • Adjustments in drop wire sag are easily made • Grips ACSR, AAAC, or aluminum conductors “FC” Flexible Bail (Bail Length – 11-1/2 in.) Rigid Stainless Steel Bail (Bail Length – 6-1/2 in. Cat. No. D L W-1 Series aluminum wedge and slider W62-1 W62-1FC W20-1 W20-1FC W40-1* W40-1FC* ACSR Conductor Range AL AAAC Dimensions (in.) D L Typical Tensile Values Conductor Value (lb.) 2–6 1 str. – 6 sol. 2–6 2-3/8 flex. 12, 17-1/2 2 6 x 1 ACSR 1200 2–6 1 str. – 6 sol. 2–6 2-3/8 flex. 12, 17-1/2 2 6 x 1 ACSR 1200 1/0–4 2/0 str. – 2 sol. 1/0–4 2-3/8 flex. 12-1/2, 18-1/2 1/0 6 x 1 ACSR 1800 1/0–4 2/0 str. – 2 sol. 1/0–4 2-3/8 flex. 12-1/2, 18-1/2 1/0 6 x 1 ACSR 1800 4/0–2/0 4/0 str. – 2 sol. 4/0–2/0 2-3/8 flex. 12-3/4, 18-1/2 4/0 6 x 1 ACSR 1900 4/0–2/0 4/0 str. – 2 sol. 4/0–2/0 2-3/8 flex. 12-3/4, 18-1/2 4/0 6 x 1 ACSR 1900 * W40 series clamps rated 850 lb. ultimate tension for 1/0 ACSR, AL, or AAAC. w w w. t n b. c a D69 Meter Sockets Carlon Nonmetallic Conduits ® Schedule 40 PVC Rigid Nonmetallic Conduits Product Specifications Certified for underground applications encased in concrete or direct burial. Also for use in exposed or concealed above ground applications. • Sunlight resistant • Rated for use with 75˚C conductors • Superior weathering characteristics • Meets CSA Standard • 3/4 in. – 4 in. are FT-4 Rated Guy Strain Insulator Cat. No. 10 ft. 49009CC-010 49010CC-010 49011CC-010 Nom. Size (in.) Std. Crate Qty. 10 ft. 1-1/4 3300 1-1/2 1800 2 1400 Std. Bundle Qty. 10 ft. Wt. Per 100 ft. Dimensions O.D. I.D. 46 1.660 1.380 50 55 1.900 1.610 73 2.375 2.067 Acceptable Dimensions in Inches of CSA Listed Integral Bell A Nom. Size (in.) C 1-1/4 1-1/2 2 A At Entrance Maximum Minimum 1.689 1.665 1.930 1.906 2.405 2.381 B At Bottom Maximum Minimum 1.667 1.643 1.906 1.882 2.381 2.357 C Socket Depth Maximum Minimum 3.938 1.062 2.00 1.125 For more information or for other sizes, contact your Regional Sales Office B D70 w w w. t n b. c a Meter Sockets Carlon Nonmetallic Conduits ® Schedule 40 PVC Rigid Nonmetallic Conduits E F Service Entrance Caps 3 Places Knockouts for conductors «H» «G» Cat. No. Size (in.) Std. Ctn. E998G E998H E998J 1-1/4 1-1/2 2 20 10 5 Dimensions (in.) F G E H 3.52 0.74 0.71 0.50 4.26 0.83 0.78 0.56 Meter Offset Cat. No. Size (in.) 1-1/4 E995G Std. Ctn. 20 Offset 0.758 A (in.) 4.230 A 2 Hole Nonmetallic Clamps C D J 2 Places B G F A E H Cat. No. Sizes in. (mm) E977GC 1-1/4 (35) E977HC Std. Ctn. (lb.) Dimensions in. (mm) A B C D E F G H J 50 1.714 (43.5) 2.68 (68.0) 3.28 (83.3) 0.64 (16.2) 0.15 (3.8) 0.83 (21.0) 1.687 (42.8) 1.89 (48.0) 0.320 (8.1) 1-1/2 (41) 50 1.920 (48.7) 2.82 (71.6) 3.44 (87.3) 0.70 (17.7) 0.15 (3.8) 0.97 (24.6) 1.930 (49.0) 2.12 (53.8) 0.312 (7.9) E977JC 2 (53) 25 2.54 (64.5) 3.54 (89.9) 4.18 (106.1) 0.76 (19.3) 0.16 (4.0) 1.05 (26.6) 2.29 (58.1) 2.49 (63.2) 0.315 (8.0) E977LC-CAR 3 (78) 20 3.47 (88.2) 5.00 (127.0) 6.00 (152.4) 1.00 (25.4) 0.20 (5.08) 1.74 (44.3) 3.48 (88.4) 3.70 (94.0) 0.360 (9.14) Nonmetallic clamps offer the same chemical resistance as Carlon nonmetallic conduits for a complete, corrosion resistant system. UV inhibited for use in direct sunlight. For more information or other sizes, contact your Regional Sales Office Schedule 40 Elbows – Std. Radius Cat. No. Size (in.) 1-1/4 1-1/2 2 UA9AGCB-UPC UA9AHCB-UPC UA9AJCB-UPC 90° Belled End Std. Ctn. 20 25 20 Available in plain and integral belled end for use with nonmetallic solvent weld fittings. Custom elbows available on request. R 90° Elbow Integral Belled End Dimensions A C B w w w. t n b. c a Trade Size (in.) 1-1/4 1-1/2 2 A At Entrance (in.) Max. Min. 1.689 1.665 1.930 1.906 2.405 2.381 B At Bottom (in.) Max. Min. 1.667 1.643 1.906 1.882 2.381 2.357 C Socket Depth (in.) Max. Min. 0.938 2.000 1.062 1.125 D71 Meter Sockets Carlon Nonmetallic Conduits ® Rigid Nonmetallic Conduits Conduit Bodies – Type LB Q L1 L2 C W Cat. No. Size (in) Std. Ctn. C Typical (in.) E986G E986H E986J 1-1/4 1-1/2 2 10 1-3/32 Typical (in.) Max. L1 (in.) L2 7-31/32 Max. H (in.) L3 6 6-13/32 9-31/32 2-5/16 7-1/4 Max. Q (in.) Max. W (in.) Vol. Cu. in. 2-1/2 2-3/4 32.0 3-5/32 3-15/32 63.0 C 1.208 1.155 1.145 1.643 Typical (in.) S 0.816 0.802 0.825 0.797 L 1.986 2.105 2.093 2.660 H L3 Male Terminal Adapters Cat. No. L S OD A D B C E943G E943H E943J E943L Size (in.) Std. Ctn. 1-1/4 1-1/2 2 3 50 25 50 45 Typical (in.) A B 1.677 1.655 1.918 1.894 2.393 2.369 3.515 3.492 Min. D (in.) Max. OD (in.) 1.345 1.574 1.998 2.989 1.973 2.188 2.713 3.965 For adapting nonmetallic conduits to boxes, threaded fittings, metallic systems. Male threads on one end, socket end on other. ® Iberville Steel Locknuts Cat. No. Trade Size (in.) CI1710 CI1712 CI1716 CI1724 1-1/4 1-1/2 2 3 Expansion Fitting Cat. No. Size (in.) Std. Ctn. Travel Length (in.) E945L 3 10 8 PVC Conduit to DB/2 Duct Adapter Cat. No. CE942RL D72 Size (in.) Std. Ctn. 3 1 w w w. t n b. c a Meter Sockets Carlon PV-Mold ™ ® Nonmetallic Pole Riser System Carlon® PV-Mold™ is a nonmetallic pole riser system designed to protect communications power cable installed on poles. Product Specifications • Meets or exceeds requirements outlined in the National Electric Safety Code (NESC) • Designed in accordance with NEMA TC-19 specifications • Ultraviolet, cold temperature and corrosive atmosphere resistant • No grounding required • Belled end fits over each added section or conduit • Requires no maintenance • PV-Mold™ acts as an insulator against electrical shock • Interchangeable parts and accessories to match the needs of specific requirements STEEL U-GUARD REQUIRES GROUNDING STRAPPING AND DOES NOT HAVE BELLED ENDS. PV-MOLD™ HAS BELLED ENDS, FLANGED DESIGN AND DOES NOT REQUIRE GROUNDING. Size (in.) B Depth of Bell (in.) 1 1-1/2 2 3 4 5 3 – 3-1/4 4 – 4-1/4 4 – 4-1/2 6 5 – 5-1/2 2 – 2-1/4 H A C FLANGED OVERALL LENGTH 10 FT., INCLUDING BELL Slots are 1/2 in. from side to side, and allow for expansion and contraction. Slot Dimensions: for sizes 2 in. through 6 in. are 5/16 in. wide, 3/4 in. long. Slot Dimensions: for 1 in. and 1-1/2 in. are 3/16 in. wide, 3/4 in. long. Slot Spacing: 18 in. from center, beginning 6 in. from end. Cat. No. Standard Duty 59208N 59211N 59213N 59215N 59216N Heavy Duty Schedule 40 59010N 59011N 59013N 59015N 59016N 59017N Size (in.) Std. Ctn. Std. Ctn. Wt. (lb.) 1 2 3 4 5 294 136 66 65 30 1059 726 761 910 515 1-1/2 2 3 4 5 6 200 136 66 65 30 30 1142 1214 937 1621 870 1160 Dimensions (in.) A 0.100 0.150 0.145 0.154 0.216 0.237 0.258 0.280 B C H 1-5/8 2-3/8 3-1/2 4-1/2 5-1/2 2-3/8 4-1/2 6 6-1/2 7-1/2 1-5/8 2-3/8 3-1/2 4-1/2 5-1/2 2-29/32 2-3/8 3-1/2 4-1/2 5-1/2 6-5/8 3-1/2 4-1/2 6 6-1/2 7-1/2 8-3/4 1-29/32 2-3/8 3-9/32 4-1/2 5-1/2 6-5/8 Actual Impact @ 0 oC 20 Pound Tup 40 ft. – lb. 100 ft. – lb. 110 ft. – lb. 100 ft. – lb. 150 ft. – lb. 260 ft. – lb. For more information on PV-Mold™, contact your Regional Sales Office. w w w. t n b. c a D73 Meter Sockets Carlon PV-Mold™ ® PV-Mold™ Installation and Fittings Polyethylene Vented Boots and Adapters Note: 1. A field cut may be needed to accommodate different boot or adapter to Carlon® U-Mold size combinations. 2. Recommendation: 2 sets of mounting holes per boot/fitting. To add mounting holes, use a 3/8 in. drill bit and drill out where needed. 3. When 3 in. or smaller conduit is being used, it’s recommended that the bottom (largest section) of the boot or adapter section be buried 2 in. to 3 in. below ground surface. E E A A B A B A B C C B D C D C D E938JR E938NT D E938NRR E938PRR Vented Boots Cat. No. Size (in.) E938JR E938NT E938NRR E938PRR 2x6 4x8 4x6 5x6 A 20.50 21.00 20.87 16.74 Dimensions (in.) C 6.13 11.34 12.87 10.84 B 4.80 15.00 16.57 3.65 D 6.20 9.76 11.68 11.43 E – – 11.43 – Std. Ctn. Std. Ctn. Wt. (lb.) 4 4 6 6 13.5 21.0 26.4 23.2 Adapters A A B C D E939JN Cat. No. Size (in.) E939JN E939NR 2x4 4x6 A 11.00 11.00 Dimensions (in.) B C 6.75 5.88 6.75 7.08 D 5.07 7.13 Std. Ctn. Std. Ctn. Wt. (lb.) 8 6 10.0 11.7 B C D E939NR B Cat. No. Size (in.) E939NRT 4x6 C A Dimensions (in.) A B C D E 19.75 4.25 12.50 8.50 7.40 Std. Ctn. Std. Ctn. Wt. (lb.) 63 14.0 E E939NRT D74 w w w. t n b. c a Meter Sockets ® Carlon PV-Mold™ PV-Mold™ Installation and Fittings – Polyethylene Vented Boots and Adapter Duct to Riser Fittings Cat. No. Size (in.) Std. Ctn. E939NL E939N 4x3 4x4 15 Std. Ctn. Wt. (lb.) 5.6 5.3 Backing Plates A C w w w. t n b. c a B Cat. No. Size (in.) 59111 59113 59115 59116 59117 59111P 59113P 59115P 59116P 59117P 2 3 4 5 6 2 3 4 5 6 Length (ft) 10 A 1/16 1/16 1/16 1/16 1/16 2.24 3.41 4.37 5.15 5.90 Dimensions (in.) B 13/16 1-5/16 1-5/16 1-3/4 1-5/8 0.575 0.570 0.562 0.600 1.40 C 2-1/8 3-1/8 4-1/8 5-1/4 6-1/16 0.050 0.060 0.050 0.060 Std. Ctn. Std. Ctn. Wt. (lb.) 1 1.2 1.5 3.0 3.1 4.2 1.4 1.5 3.0 3.4 3.9 D75 Meter Sockets Carlon® PV-Mold™ PV-Mold™ Installation Instructions Installation is easy with PV-Mold™ Pole Risers: 1. Install ventilator or duct to riser fittings at the base of the pole. 2. Nail backing plate sections to the surface of the pole. Three nail holes are provided in each section. Place the “U” sections over the cable and backing plate, with belled end at the bottom, and attach using 1/4 in. lag bolts. Flanged Exclusive Bell End For easy and quick installation. (No additional coupler required.) 10’ Lengths Safe and light for easy handling during installation. Backing Plate Provides cable isolation from the pole. Ventilator Fitting Used for a “chimney” effect to cool cable and increase ampacity. E939JN E939NRT Two Riser Fittings Available Duct to riser fitting Adapts duct to PV-Mold™. E939NR Field Installation Instructions for Carlon® PV-Mold™ Adapters (for Adapters E939JN, E939NR, E939NRT) E939JN To transition from 4 in. Conduit to 2 in. PV-Mold™ Place Adapter over conduit, attach to pole using the top and bottom mounting holes, place PV-Mold™ over top section of Adapter and secure PV-Mold to pole. To transition from 4 in. Conduit to 3 in. PV-Mold™ Measure 6.3 in. up from bottom (large end) of adapter and cut. Assemble to pole as described above. ™* To transition from 3 in. Conduit to 2 in. PV-Mold Measure 4.75 in. up from bottom (large end) of adapter and cut. Assemble to pole as described above. E939NR To transition from 5 in. Conduit to 4 in. PV-Mold™ Place Adapter over conduit, attach to pole using the top and bottom mounting holes, place PV-Mold™ over top section of Adapter and secure PV-Mold™ to pole. To transition from 6 in. Conduit to 5 in. PV-Mold™ Measure 7.25 in. up from bottom (large end) of adapter and cut. Assemble to pole as described above. To transition from 5 in. Conduit to 5 in. PV-Mold™* Measure 4.5 in. down from the top of adapter and cut. Assemble to pole as described above. * For these transitions it is not necessary to cut the Adapter if desired. If the Adapter is not modified, it is recommended that the bottom 3 in. of the Adapter be buried below grade. E939NRT To transition from 6 in. Conduit to 4 in. PV-Mold™ Place Adapter over conduit and attach to pole using the top and bottom mounting holes. Place PV-Mold™ over top section of Adapter and secure PV-Mold™ to pole. To transition from 6 in. Conduit to 5 in. PV-Mold™ Measure 5.25 in. down from the top of the adapter and cut. Assemble to pole as described above. ™* To transition from 6 in. Conduit to 6 in. PV-Mold D76 Measure 9.5 in. up from the bottom of the adapter and cut. Assemble to pole as described above. w w w. t n b. c a Meter Sockets Carlon® PV-Mold™ PV-Mold™ Installation Instructions E B C D E938JR E938NT E938NRR E938PRR Field Installation Instructions for Carlon® PV-Mold™ Adapters. For Vented Boots (E938JR, E938NT, E938NRR, E938PRR) E938JR To transition from 5 in. or smaller Conduit to 2 in. PV-Mold™ To transition from 5 in. or smaller Conduit to 3 in. and larger PV-Mold™ Place Vented Boot over conduit, attach to pole using the top and bottom mounting holes, place PV-Mold™ over top section of Vented Boot and secure PV-Mold™ to pole. For 3 in. PV-Mold™: Measure 3.75 in. from the TOP of the Boot and cut. Place the Boot over the Conduit and attach to the pole. Place belled end of PV-Mold™ over the top end of the boot and secure. For 4 in. and 5 in. PV-Mold™: Measure 12 in. up from the BOTTOM of the Boot and cut. Place the Boot over the conduit and attach to the pole. Place the Belled end of the PV-Mold™ AGAINST the top edge of the vent protrusion and secure to the pole. E938NT To transition from 6 in. to 8 in. Conduit to 4 in. PV-Mold™ Place Boot over conduit and attach to the pole using the mounting holes. Place PV-Mold™ over top section of Vented Boot and secure to the pole. It is recommended that for conduit sizes smaller than 8 in., the bottom 3 in. of the boot be buried below grade. The E938NT can also be used to transition multiple smaller conduits to PV-Mold™ E938NRR To transition from 6 in. or smaller conduit to 4 in. PV-Mold™ Place Vented Boot over conduit and attach to pole using the top and bottom mounting holes. Place PV-Mold™ over top section of Vented Boot and secure PV-Mold™ to pole. To transition from 6 in. or smaller conduit to 5 in. PV-Mold™ Measure 4.125 in. down from the top of the vented boot and cut. Assemble to pole as described above. To transition from 6 in. or smaller conduit to 6 in. PV-Mold™* Measure 8.25 in. down from the top of the vented boot and cut. Assemble to pole as described above. E938PRR To transition from 6 in. or smaller conduit to 5 in. PV-Mold™ w w w. t n b. c a Assemble to pole as described above. D77 Meter Sockets ® E-Z-Ground Grounding Systems Waterpipe Ground Clamps Cat. No. Ground Wire Size Water Pipe Size #6, #4, #2 AWG 1/2 in., 3/4 in., 1 or rebar 4-10 1-1/4 in., 1-1/2 in. or 2 in. 2-1/2 in., 3 in. or 3-1/2 in. 4 in., 4-1/2 in. or 5 in. 6 in. 2-TB 3-TB 4 5-TB 6 Ground Wire Size Water Pipe Size Cat. No. #4–4/0 AWG 1/2 in.–1 1-1/4 in.–2 in. 2-1/2 in.–3-1/2 in. 4 in.–5 in. 6 in. 8 in. 10 in. 12 in. 3902BU* 3903BU* 3904BU* 3905BU* 3906BU* 3907BU* 3908BU* 3909BU* Cat. No. 3902 3903 3904 3905-TB 3906-TB 3907 3908 3909-TB Malleable iron crossbar, steel U-Bolt c/w copper cable clamp with serrations Material: Steel U-bolt and nut c/w bronzed aluminum cap and crossbar cadmium plated plus gold chromate finish 3849 #4–4/0 AWG 1/2 in.–1 1-1/4 in.–2 in. 2-1/2 in.–3-1/2 in. 4 in.–5 in. 6 in. 8 in. 10 in. 12 in. Material: Bronze U-bolt and nut c/w bronzed aluminum cap and crossbar with a brite dip finish. *UL Listed for Direct Burial 3826 3844 3840-TB 3826* 3846* 3849** 3840-TB• Water Pipe Size Ground Clamps for K&L Grade Copper Tubing Only Ground Clamps Cat. No. Ground Wire Size Material Malleable Iron Bronze Brass Malleable Iron For armored and unarmoured wires. Water Pipe, Copper Tubing Size Ground Rod Size Cat. No. Ground Wire Size 1/2 in., 3/4 in. 1/2 po–1 3844* 3888** #8–#4 AWG 1/2 in.–1 1/2 in., 3/4 in. or 1 – Water Pipe, Copper Tubing Size 1/2 in.–1 1/2 in.–1 also rebar 4–10 * With Steel Screws. ** UL approved for direct burial. Silicon Bronze Screws * For unarmoured copper wires #6, #4 AWG. ** For copper and aluminum conductors; for #14 thru #2 AWG unarmoured copper wires for corrosive and outdoor use. UL approved for direct burial. • #8 thru #4 AWG. Not CSA Certified. D78 w w w. t n b. c a Meter Sockets ® E-Z-Ground Grounding Systems Galvanized Grounding Plates • Made of high-quality steel, hot dip galvanized • Major time and cost saving vs ground rods 14-3/4 in. 5/8 in. 3-7/8 ± 1/4 in. 9-3/4 in. 2 ± 1/4 in. Cat. No. Description 1016TB Galvanized grounding plate 1016BTB 1016TB-NG* Wire Range Std. Pkg. 8 sol. to 4/0 str. 1 Galvanized grounding plate (complete with JAB34C connector) Grounding plate (not galvanized) Grounding plate (not galvanized) 1/4 in. 1016BTB-NG* (complete with JAB34C connector) * CSA not applicable. 1016TB - 1016BTB Ground Electrode Boxes Cat. No. Description Pregalvanized Steel Hot dip galvanized steel 51628 51629 14 gauge steel 10 in. diameter, 12 in. depth. 51628 - 51629 Knurling Dies for 14- & 15-ton Tools Cat. No. 15508 Description For 5/8 in. and 3/4 in. ground rods Used to knurl ground rods in order to increase the pullout value of the compression connection by as much as 20% Hand knurling Tool for all Ground Rods 240-31565-94 w w w. t n b. c a D79 Meter Sockets ® E-Z-Ground Grounding Systems Ground Rods Galvanized Ground Rods • Made of high-strength quality cold drawn steel, (1035) hot dip galvanized • Meets ANSI CI35.30-1979 requirements • Stainless steel rods are also available (for more detailed information, contact your T&B Regional Sales Office) Trade Size in. 1/2 Cat. No. GR5006 GR6256 GR6258 GR6250 (0.543 – 0.555) GR6260 (0.625 – 0.640) GR6250B* (0.618 – 0.623) GR7506 GR7508 GR7510 ft. 6 8 5/8 10 6 8 10 3/4 Rod Size (nominal diameter x length) mm m 12.7 1.8 1.8 2.4 15.8 19.0 Plating Thickness Standard Packaging 10 3.0 4 mils 5 1.8 2.4 3.0 Weight per 100 lb. kg 410 186 600 272 800 363 1000 454 700 1200 1500 318 545 681 * B suffix denotes black iron bare steel ground rod (CSA not applicable). CSA lists rods 1/2 in. and larger, 10 ft. and longer. Copper Bonded Steel Ground Rods • All E-Z-Ground® ground rods have a heavy uniform covering of electrolytic copper bonded to a rigid steel core • Copper ions are forced electrically to join with the steel core, establishing a corrosion-resistant bond between the copper and the steel Cat. No. 5005 5006 5008 5010 6256 6258* 6260* 7508* 7510* 1010* Trade Size in. 1/2 ft. 5 6 8 10 6 5/8 3/4 1 Rod Size (nominal diameter x length) mm m 12.7 1.8 2.4 15.8 Plating Thickness Standard Packaging 10 5 mils 3.0 5 8 10 1.8 8 2.4 10 19.0 25.4 10 mils 3.0 1 Weight per 100 lb. kg 305 138 370 168 545 247 611 277 508 230 678 308 847 384 992 450 1240 462 2248 1020 * Ground rods are UL listed (425H), except for regular rods shorter than 8 ft. or less than 1/2 in. CSA lists rods 1/2 in. and larger, 10 ft. and longer. D80 w w w. t n b. c a Meter Sockets ® E-Z-Ground Grounding Systems Ground Rods Sectional type Ground Rods • Sectional type ground rods have the same high-quality as regular copper bonded steel ground rods, and are threaded top and bottom Trade Size Cat. No. in. 5006LS 5008LS 5010LS 6256S 6258S 6260S 7506S 7508S 7510S 1010S ft. 6 1/2 8 6 8 10 6 8 5/8 3/4 10 1 Rod Size (nominal diameter x length) mm m 12.7 1.8 Plating Thickness Thread Size 10 mils 9/16–12 Standard Packaging 2.4 15.8 19.0 25.4 5 mils 3.0 1.8 2.4 3.0 10 mils 5/8–11 5 5 mils 3/4–10 10 mils 8–1 1 Weight per 100 lb. 410 546 682 481 670 837 774 992 1040 2248 kg 189 248 309 230 308 384 160 450 562 1020 CSA lists rods 1/2 in. and larger, 10 ft. and longer. Couplings • Threaded couplings are made of high-strength, corrosion resistant alloy. Streamlined design reduces driving friction. Couplings are tapped for use on all standard threaded sectional rods Cat. No. 50LC 60C 70C 80C w w w. t n b. c a Rod Diameter (in.) Thread Size 1/2 5/8 3/4 1 9/16 in. – 12 UNS 5/8 in. – 11 UNS 3/4 in. – 10 UNS 1 in. – 8 UNS Standard Packaging 25 10 Weight per 100 (lb.) 17 25 38 75 D81 Meter Sockets ® E-Z-Ground Grounding Systems Ground Rods Driving Studs • Driving Studs of high-strength steel • May be used with all standard threaded couplings Cat. No. Rod Diameter (in.) Thread Size Standard Packaging Weight per 100 (lb.) 50LDS* 60DS*+ 70DS* 80DS 1/2 9/16 in. – 12 UNS 10 16 5/8 5/8 in. – 11 UNS 25 23 3/4 3/4 in. – 10 UNS 5 35 1 1 – 8 UNS 10 75 * UL Listed +CSA Certified Threadless Couplings and Driving Caps for Standard Copper Bonded Ground Rods Threadless Couplings • For joining non-threaded, sectional, copper bonded, steel ground rods • Coupling is manufactured of a high-strength, corrosion resistant, silicone bronze Threadless Driving Caps • Prevent “mushrooming” of ground rod while driving to insure proper fit of coupling • Driving cap is manufactured of high-strength, hardened steel Cat. No. Size (in.) Dimensions (in.) Length Diameter 1/2 3.0 0.78 5/8 2.5 0.69 3/4 3.0 0.97 5/8 4.0 0.88 Standard Packaging Weight per 100 (lb.) Threadless couplings 50CNT* 60CNT2* 70CNT* 25 34 31 Driving Caps 60DSNT 10 43 * UL Listed D82 w w w. t n b. c a Meter Sockets ® E-Z-Ground Grounding Systems Clamps Type JAB — Ground Rod Clamps A Max. • Cast of high-strength corrosion resistant copper alloy • Both hex head and socket set screws available • Long bearing surface of clamp on ground wire secures ground connection • UL Listed for direct burial Cat. No. Socket Set Screw JAB12* JAB58 JAB34 – JAB1 B Nominal Rod Dia. Hex Head Bolt JAB12H JAB58H JAB34H JAB34C JAB1H D Wire Range (in.) (mm) max. min. max. (mm2) min. (mm2) 1/2 5/8 3/4 3/4 + 5/8 1 12.7 15.8 19.0 15.8 to 19.0 25.0 2 str. 10 sol. 33.6 5.2 1/0 str. 53.4 8 sol. 3/0 str. 4/0 str. 8.3 95.0 107.1 A (max.) Socket Screw 1-19/32 1-27/32 2 – 2-1/4 C Dimensions (in.) Screw Thread B C Size UNC-2A 2-3/32 27/32 7/8 2-13/64 29/32 1 7/16-14 11/16 2-11/32 1-1/8 1-1/32 3 1-11/32 1-1/16 A (max.) Hex Bolt D 19/32 11/16 51/64 13/16 1 * CSA not applicable. Add suffix P to Cat. No. for tin-plated clamp E Type G — Budget Line Ground Clamps • • • • A dependable ground connection offered at a substantial saving Cast of high-strength corrosion-resistant copper alloy Hex head bolts Simplified compact design will make a lasting, trouble-free connection • Listed for direct burial Nominal Rod Dia. Cat. No. G3* G4 G5 G6 A Max. B Wire Range (in.) (mm) max. 3/8 1/2 5/8 3/4 9.5 12.7 15.8 19.0 4 str. 2 str. min. max. (mm2) 33.6 C Dimensions (in.) min. (mm2) 21.1 10 sol. D 5.2 A (max.) Bolt 1-3/8 Screw Thread Size UNC-2A 5/16-18 – 3/8-16 B C D E 11/16 27/32 29/32 1-1/16 1/2 27/64 37/64 43/64 13/16 3/8 3/8 1/2 * Not UL Listed and CSA not applicable. Add suffix P to Cat. No. for tin-plated clamp w w w. t n b. c a D83 Meter Sockets E-Z-Ground Grounding Systems ® Clamps Cast Bronze Ground Clamps Connect copper ground wire to water pipe, copper tubing or ground rods • High-strength, high-conductivity copper alloy (over 80% copper) • UL Listed for direct burial Cat. No. Water Pipe Size (in.) JD J2D Conductor Range 1/2 to 1 #2 str.–#10 str. 1-1/4 to 2 Type J — Cast Bronze Ground Clamps For connecting grounding conductor to water pipe or copper tube • Cast of high-strength, highly conductive copper alloy • Screws plated for corrosion resistance • UL Listed D84 Cat. No. Water Pipe Size (in.) J J2BB J2124 J6 1/2 to 1 1-1/4 to 2 2-1/2 to 4 4-1/4 to 6 Conductor Range Max. 2 str. Min. 10 sol. Dimensions (in.) A B C 2-3/4 2-11/32 23/32 3-3/4 3-1/2 13/16 6 6-5/16 7-1/4 8-1/8 1 w w w. t n b. c a Meter Sockets E-Z-Ground Grounding Systems ® Clamps Technical Specifications Cat. No. Water Pipe Size (in.) Ground Wire Size (AWG) min. max. Galv. Steel Copper Clad Ground Clamps (Zinc alloy body/Steel screws) CI3106 1/2 to 1 10 sol. 2 str. 5/8 to 1* N/A 10 sol. 2 str. 5/8 to 1* N/A 2 str. 5/8 to 1* 5/8 to 1 – – Ground Clamps (Zinc/Steel) CI3108 CI3106 1/2 to 1 For connecting grounding conductor to either galvanized steel rod or water pipe. Ground Clamps (Brass body/brass screws) CI3110U 1/2 to 1 10 sol. For connecting grounding conductor to either galvanized steel rod, copper clad or water pipe. CSA approved for wet locations and for direct burial. Ground Clamps (Brass body/brass screws) CI3112U 1-1/4 to 2 10 sol. 2 str. For connecting grounding conductor to water pipe. CSA approved for wet locations and for direct burial. CI3108 Ground Rod Clamps (Bronze body/brass screws) CIGRC58 CIGRC34 N/A 10 sol. 8 sol. 2 str. 1/0 str. 5/8 3/4 5/8 3/4 For connecting grounding conductor to either galvanized steel rod or copper clad rod. CSA approved for wet locations and for direct burial. *Reversible. CI3110U CI3112U CIGRC58 w w w. t n b. c a D85 Meter Sockets E-Z-Ground® Types of Connectors used in our Meter Sockets Tunnel Type Connector A tunnel type connector is made of aluminum and is ideally suited for grounding and bonding applications accommodating both copper and aluminum conductor size #6 AWG to 250 kcmil. Dual Tunnel Type Connector A tunnel type connector is made of aluminum and is ideally suited for grounding and bonding applications accommodating both copper and aluminum conductor size #6 AWG to 250 kcmil. Stud Connector Stud connector is made of zinc plated steel suited for copper or aluminum wire sizes of #6 AWG to 350 kcmil. Connector is comprised of a stud nut, washer and bell nut. Lay-in Type Connector A Lay-in lug is made of aluminum and is ideally suited for grounding and bonding applications accommodating both copper and aluminum conductor sizes #14 AWG to 250 kcmil. Compression Lug Made of high conductivity wrought copper. Supplied by utility based on wire size requirements. D86 w w w. t n b. c a
Similar documents
Mutual fund list
AB Multi-Manager Select 2035 I AB Multi-Manager Select 2035 K AB Multi-Manager Select 2035 R AB Multi-Manager Select 2035 Z AB Multi-Manager Select 2040 A AB Multi-Manager Select 2040 Advisor AB Mu...
More information