Meter Sockets

Transcription

Meter Sockets
Meter Sockets
Table of Contents
20 A 600 V – CL, CT, CT-SWL Series .............................................. D3–D5
100 A 600 V – R3, BA3 Series ........................................................ D6–D7
100 A 600 V King Size – BE1 Series .......................................................D8
100 A per Position 200 A 600 V – BE2, BEC Series ....................... D9–D10
100 A 600 V Polyphase – PL17 Series ................................................. D11
100 A 120/240 V – CO1 Series ............................................................ D12
100 A per Position 120/240 V – CO1 Multi-Gang .................................. D13
100 A 120/240 V – HD Series ............................................................... D14
200 A 600 V – BQ, BP, BS2, BS4M-V, MO2 Series ...................... D15–D25
200 A per Position 200 A 600 V – BD, BDA, BDC, BS4 Series .....D26–D29
200 A per Position 400 A 600 V – BSC4-G Series ..............................D30
200 A 600 V Polyphase – PL27 Series .................................................D31
200 A 120/240 V – CO2 Series ................................................... D32–D33
200 A 120/240 V – CO22, CO23, CO24 Series .....................................D34
200 A 120/240 V – CO22-U, CO23-U, CO24-U Series .........................D35
400 A 120/240 V – CO42 Series ...........................................................D36
200 A 120/208 V – CO27 Series ..........................................................D37
320 A 600 V – BP320 Series ...............................................................D38
400 A 600 V – FA4B-6T .......................................................................D39
400 A 120/240 V – JS4 Series ................................................... D40–D41
Typical Wiring Diagrams .............................................................. D42–D43
Accessories .................................................................................D44–D48
Meter Covers ........................................................................................D49
Service Masts.............................................................................. D50–D59
Pole Line Hardware .....................................................................D60–D69
Carlon® Nonmetallic Conduits ...................................................... D70–D72
Carlon® PV-Mold™ ....................................................................... D73–D77
E-Z-Ground® Grounding Systems ................................................. D78–D85
E-Z-Ground® Types of Connectors ........................................................D86
w w w. t n b. c a
D1
Meter Sockets
D2
w w w. t n b. c a
Meter Sockets
CL Series
20 A 600 V; Transformer Rated
Product Specifications
•
•
•
•
•
•
•
Conductor range: 14-10 AWG
Aluminum tunnel type connectors for both load and line sides
Circuit closing feature to short out current transformer upon removal of meter
For overhead hub opening only
Supplied with screw type ring
Weatherproof Type 3R enclosure
Primarily used in: Sask., Man., Ont., N.B., N.S., P.E.I., Nfld.
(CL4-V)
3-11/16 in.
Trade Size
Knockout
1-1/4 and 1-1/2 in.
1 Place
Trade Size
Knockout
1/2, 1 and 1-1/4 in.
2 Places
4-5/8 in.
Trade Size
Knockout
3/4, 1 and 1-1/4 in.
3 Places
9-1/4 in.
1-3/8 in.
1-1/2 in.
1/2 in.
1-3/4 in.
2-9/16 in.
Trade Size
Knockout 1/4 in.
1 Place
1-9/16 in.
Approved for copper only
Cat. No.
4 JAW
CL4-V
CL4-LRV
CL4-TV
5 JAW
CL5-V
6 JAW
CL6-LRV
w w w. t n b. c a
H
Dimensions (in.)
W
D
9-1/4
7-5/8
3-11/16
7
3.1
Circuit closing on left side (Lower right hand jaw is a support only)
9-1/4
7-5/8
3-11/16
7
3.1
Circuit closing both left and right sides
9-1/4
7-5/8
3-11/16
7
3.1
Description
Weight Each
lb.
kg
Circuit closing on left side
Circuit closing both left and right sides
Circuit closing on left side, no hub opening
D3
Meter Sockets
CT Series
20 A 600 V; Transformer Rated c/w Compartment
for Test Switch
Product Specifications
• Conductor range: 14-10 AWG
• Tunnel type connectors for both load
and line sides
• For underground service only
• Meter compartment cover overlaps lower test
switch compartment cover;
insertion of meter securely holds upper cover
in place by means of a catch
• Lower test switch compartment cover
securely held by upper cover and a catch
at bottom
19-1/8 in.
• A removable mounting bridge is provided
for fastening test switch
• Supplied with screw type ring
• Primarily used in: AB, Sask., Man.,
Ont., N.B., N.S., P.E.I.
(CT113)
Trade Size
Knockout
3/4, 1
and 1-1/4 in.
3 Places
5-7/16 in.
3/8 in.
1-5/16 in.
3-5/8 in.
13/16 in.
Trade Size
Knockout
1/2 in.
1 Place
7-7/8 in.
1-3/4 in.
Trade Size
Knockout
1/2 in.
1 Place
1-15/16 in.
1-7/16 in.
Trade Size Knockout
3/4, 1 and 1-1/4 in.
3 Places
1-1/2 in.
Approved for copper only
H
Dimensions (in.)
W
D
Unwired unit with test switch provision
19-1/8
11-13/16
5-7/16
16
7.2
Unwired unit with test switch provision
19-1/8
11-13/16
5-7/16
16
7.2
Unwired unit with test switch provision
19-1/8
11-13/16
5-7/16
18
8.1
Unwired unit with test switch provision
19-1/8
11-13/16
5-7/16
19
8.6
Cat. No.
4 JAW
CT104
5 JAW
CT105
8 JAW
CT108
13 JAW
CT113
Description
Lower test switch compartment cover securely held by upper cover
and a out device with an enlarged pad hole (0.375 in. dia.)
Cat. No.
5 JAW
CT105-L
8 JAW
CT108-L
13 JAW
CT113-L
D4
Description
Weight Each
lb.
kg
Approved for copper only
H
Dimensions (in.)
W
D
Weight Each
lb.
kg
BC Hydro approved with SWL cover with enlarged padlock hole
19-1/8
11-13/16
5-7/16
16
7.2
BC Hydro approved with SWL cover with enlarged padlock hole
19-1/8
11-13/16
5-7/16
18
8.1
BC Hydro approved with SWL cover with enlarged padlock hole
19-1/8
11-13/16
5-7/16
19
8.6
w w w. t n b. c a
Meter Sockets
CT-SWL Series
20 A 600 V; Transformer Rated c/w Test Switch
Product Specifications
•Conductor range: 14-10 AWG
•Tunnel type connectors for both load and line sides
•For underground service only
•Lower test switch compartment cover securely held by upper cover and a out
device with an enlarged pad hole (0.375 in. dia.)
•Test switch included as part of these models
•Units are prewired from base to test switch
•Furnished with tamper resistant device for meter ring
•Weatherproof Type 3R enclosure
•Primarily used in: Alberta
(CT104-5SWLHQ for Hydro-Québec only)
Trade Size
Knockout
3/4, 1 and
1-1/4 in.
3 Places
(CT104-SWL)
5-7/16 in.
19-1/8 in.
3/8 in.
1-5/16 in.
3-5/8 in.
13/16 in.
Trade Size
Knockout
1/2 in.
1 Place
1-5/16 in.
7-7/8 in.
1-7/16 in.
Trade Size
Knockout
1/2 in.
1 Place
1-3/4 in.
Trade Size
Knockout
1/2, 3/4, 1 and 1-1/4 in.
3 Places
Cat. No.
4 JAW
CT104-SWL
CT104-6SWL
CT104-5SWLHQ
5 JAW
CT105-SLHO
6 JAW
CT106-SWL
13 JAW
CT113-SWL
w w w. t nb. c a
Approved for copper only
1-1/2 in.
H
Dimensions (in.)
W
D
19-1/8
11-13/16
5-7/16
18
8.2
18
8-1/4
4-1/2
11
5.4
Hydro One approved 20 A current transformer meter socket
19-1/8
11-13/16
5-7/16
18
8.2
Factory prewired unit with lockout device on bottom door
19-1/8
11-13/16
5-7/16
21
9.5
Factory prewired unit with lockout device on bottom door
19-1/8
11-13/16
5-7/16
21
9.5
Description
Factory prewired unit with lockout device on bottom door
Factory prewired unit with lockout device on bottom door
(Enmax approved) 5th Jaw in 6 o’clock position
Hydro-Québec approved 20 A current transformer meter socket
Weight Each
lb.
kg
D5
Meter Sockets
R3 Series
100 A 600 V; Round Aluminum
Product Specifications
•Conductor range: 14-2 AWG
•Aluminum tunnel type connectors for both load and line sides
•Can be converted from vertical to horizontal mounting using same components
•Supplied with screw type ring
•Aluminum die cast socket
•Weatherproof Type 3R enclosure
•Primarily used in: B.C., Northern Ont.
(R3-1V)
2-7/8 in.
1-1/8 in.
2-1/8 in.
2-7/8 in.
5-1/8 in.
7-1/8 in.
Approved for copper only
Cat. No.
4 JAW
R3-1V
R3-1-1/4V
R3-1-5V
R3-1 1/4-5V
D6
Description
1 in. hub
1-1/4 in. hub
1 in. hub - 5th jaw, standard capacity, 9 o’clock position
1-1/4 in. hub - 5th jaw, standard capacity, 9 o’clock position
Dimensions (in.)
Dia.
7-1/8
D
3-1/8
Weight Each
lb.
kg
2
0.9
w w w.t nb.c a
Meter Sockets
BA3 Series
100 A 600 V; Shallow
Product Specifications
•
•
•
•
•
•
Conductor range: 6-2 AWG
Aluminum tunnel type connectors for both load and line sides
For overhead, underground and combination overhead/underground
Supplied with screw type ring
Weatherproof Type 3R enclosure
Primarily used in: All provinces
Note: Supply from an underground network often requires use of stud type connector.
Consult your local utility.
(BA3-1 1/4V)
5 in.
1-9/16 in.
Trade Size
Knockout
1/2, 1 and 1-1/4 in.
2 Places
6-1/8 in.
9-1/4 in.
Trade Size
Knockout
1-1/4, 1 and 1-1/2 in.
Trade Size
Knockout
1/4 in.
1-7/16 in.
1-5/16 in.
7/16 in.
1-7/16 in.
1-7/16 in.
7-7/16 in.
2-9/16 in.
Approved for copper only
Cat. No.
Description
4 JAW
Overhead, hub opening
BA3-V
Overhead, hub opening, c/w 1 in. hub
BA3-1V
Overhead, hub opening, c/w 1-1/4 in. hub
BA3-1 1/4V
Underground
BA3-TV
Combination overhead-underground
BA3-TCV
Overhead, twin hub opening
BA33-V
Overhead, twin hub opening c/w 1 in. hubs
BA33-1V
Overhead, twin hub opening, c/w 1-1/4 in. hubs
BA33-1 1/4V
Indoor type, K.O. on top
BA4-V
FACTORY-INSTALLED ACCESSORIES
Insulated Neutral
Include: -IN
5th jaw, standard capacity, 9 o’clock position
-5
5th jaw, full capacity, 9 o’clock position
-9
w w w. t n b. c a
H
Dimensions (in.)
W
D
9-1/4
7-7/16
3-11/16
Weight Each
lb.
kg
5
2.2
D7
Meter Sockets
BE1 Series
100 A 600 V; King Size
Product Specifications
•
•
•
•
•
•
Conductor range: 6-1/0 AWG
Aluminum tunnel type connectors for both load and line sides
For overhead, underground and combination overhead/underground
Supplied with screw type ring
Weatherproof Type 3R enclosure
Primarily used in all provinces
Note: Supply from an underground network often requires use of stud type connector.
Consult your local utility.
4-3/8 in.
Trade Size
Knockout
1/4 in.
(BE1-1 1/4V)
Trade Size
Knockout
1, 1-1/4, 1-1/2 and 2 in.
2 Places
Trade Size
Knockout
1/2 in.
Trade Size
Knockout
1/2 in.
Trade Size
Knockout
1/4 in.
3/4 in.
14-5/8 in.
1-13/16 in.
3/4 in.
3-3/8 in.
1-1/4 in.
3 in.
Trade Size
Knockout
1-1/4, 1-1/2 and 2 in.
1-13/16 in.
OVERHEAD BOTTOM
2 in.
2-1/16 in.
1-7/16 in.
4 in.
Trade Size
Knockout
1-1/4, 1-1/2 and 2 in.
COMBINATION AND UNDER
GROUND BOTTOM
Cat. No.
Description
4 JAW
Overhead, hub opening
BE1-V
Overhead, hub opening, c/w 1-1/4 in. hub
BE1-1 1/4V
Overhead, hub opening, c/w 1-1/2 in. hub
BE1-1 1/2V
Underground
BE1-TV
Combination overhead-underground
BE1-TCV
Overhead, twin hub opening
BE11-V-CM
Overhead, twin hub opening c/w 1-1/4 in. hubs
BE11-1 1/4V
FACTORY-INSTALLED ACCESSORIES
5th jaw, standard capacity, 9 o’clock position
Include: -5
5th jaw, full capacity, 9 o’clock position
-9
5th jaw, full capacity, 6 o’clock position
-6
Insulated neutral
-IN
Water heater lugs
-W
D8
1-13/16 in.
Approved for copper or aluminum
Dimensions (in.)
Weight Each
H
W
D
lb.
kg
14-5/8
8-1/4
4-3/8
8
3.6
w w w. t n b. c a
Meter Sockets
BE2 Series
200 A (Main Lugs) 600 V; Multiple Position – Horizontal 100 A per Position
Product Specifications
(BE6-V)
•
•
•
•
NOTE: Supply from an underground network often requires use
of stud type connector. Consult your local utility.
5-3/16 in.
•
•
•
•
Trade Size
Knockout
1-1/4, 1-1/2 and 2 in.
Trade Size
Knockout
1/2
2 Places
14-5/8 in.
Conductor range: Line: 6 AWG-250 kcmil, Load: 6-1/0 AWG
Aluminum tunnel type connectors for both line and load sides
Factory prebussed from main lugs to each position
Combination overhead-underground supplied with
hub opening closure plate for underground service
Hubs to be ordered separately (refer to pp. D39 and D40)
Supplied with screw type rings
Weatherproof Type 3R enclosure
Primarily used in: All provinces
Trade Size
Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
(each side of the box separation)
(for every box separation)
8-5/16 in.
8-3/16 in.
(for each end
of the bottom)
2-3/16 in.
1-13/16 in.
1-1/16 in.
1-1/16 in.
4-1/8 in.
4-1/16 in.
8-5/16 in.
8-5/16 in.
2-1/2 in.
2-1/4 in.
Approved for copper or aluminum
Cat. No.
4 JAW
LEFT-HAND ENTRY RIGHT-HAND ENTRY
BE2-V
BE2-VH
BE3-V
BE3-VH
BE4-V
BE4-VH
BE5-V
BE5-VH
BE6-V
BE6-VH
FACTORY-INSTALLED ACCESSORIES
Include:
-5
w w w. t n b. c a
Meter Position
2 position
3 position
4 position
5 position
6 position
H
14-5/8
Dimensions (in.)
W
16-1/2
24-13/16
33-1/8
41-7/16
49-3/4
D
5-3/16
Weight Each
lb.
kg
18
26
34
42
50
8.1
11.8
15.4
19.0
22.7
5th jaw, standard capacity, 9 o’clock position
D9
Meter Sockets
BEC Series
200 A (Main Lugs) 600 V; Multiple Position –
100 A per Position Stud Type
Product Specifications
•Conductor range: Line: 1/2 in. studs supplied, Load: 6-1/0 AWG
•Aluminum tunnel type connectors load side; stud 1/2 in. line side
•For underground service only
• Factory prebussed from main lugs to each position
• Supplied with screw type rings
• Weatherproof Type 3R enclosure
•Primarily used in: B.C., *Sask. (extended enclosure), Man., Ont., Que.
(BEC2-V)
*N
ote: Models with suffix -VA and -VAH = tunnel type connectors on line side provided instead of studs
(required by B.C. Hydro). Conductor range: Line: 1–1/0 AWG, Load: 6–1/0 AWG.
Cross Reference
Underground meter required by BC Hydro Standard
Step
8-5/16 in.
16-1/2 in.
Required by BC Hydro
Not accepted by BC
Hydro for underground for underground
applications
application
15-1/8 in.
1/16 in.
4 in.
Step
8-5/16 in.
12-5/16 in.
PATTERN FOR BOTTOM
2-1/2 in.
Trade Size
Knockout
1/2 in.
2 Places
Trade Size
Knockout
1-1/2, 2, 2-1/2
and 3 in.
1 Place
Trade Size
Knockout
1-1/4, 1-1/2
and 2 in.
Typical
Trade Size
Knockout
1-1/4, 1-1/2,
2 and 2-1/2 in.
Typical
BE2-V
BE3-V
BE4-V
BEC2-VH
BEC3-VH
BEC4-VH
BEC2-V
BEC3-V
BEC4-V
BEC2-VH
BEC3-VH
BEC4-VH
BEC2-VA
BEC3-VA
BEC4-VA
BEC2-VAH
BEC3-VAH
BEC4-VAH
BEC2-VA
BEC3-VA
BEC4-VA
BEC2-VAH
BEC3-VAH
BEC4-VAH
2-1/8 in.
5 in.
2-1/16 in.
2-3/8 in.
1-1/16 in.
1-7/8 in. 2-1/16 in.
1-1/16 in.
1-1/4 in.
1-1/16 in.
4 in.
Cat. No.
4-1/8 in.
Meter Position
4 JAW
LEFT-HAND ENTRY RIGHT-HAND ENTRY
2 position
BEC2-V
BEC2-VH
2 position c/w connector (tunnel type)
BEC2-VA*
BEC2-VAH
2 position extended enclosure
BEC2-VE*
BEC2-VEH
3 position
BEC3-V
BEC3-VH
3 position c/w connector (tunnel type)
BEC3-VA*
BEC3-VAH
3 position extended enclosure
BEC3-VE*
–
4 position
BEC4-V
BEC4-VH
4 position c/w connector (tunnel type)
BEC4-VA*
BEC4-VAH
4 position extended enclosure
BEC4-VE*
–
5 position
BEC5-V
BEC5-VH
6 position
BEC6-V
BEC6-VH
FACTORY INSTALLED ACCESSORIES
5th jaw, standard capacity, 9 o’clock position
Include:
-5
D10
4-3/16 in.
Approved for copper or aluminum
4-3/16 in.
H
15-1/8
Dimensions (in.)
W
D
24-3/16
Weight Each
lb.
kg
27
12.2
35
15.9
41-7/16
43
19.5
49-3/8
57-5/8
51
59
23.1
26.8
20-1/16
15-1/8
33-1/8
20-1/16
15-1/8
5
20-1/16
15-1/8
w w w.t nb.c a
Meter Sockets
PL17 Series
100 A 600 V; Polyphase
Product Specifications
•
•
•
•
•
•
Conductor range: 6-1/0 AWG
Aluminum tunnel type connectors for both load and line sides
For overhead, underground and combination overhead/underground
Supplied with screw type ring
Weatherproof Type 3R enclosure
Primarily used in: All provinces
5-7/16 in.
(PL17-INV)
Trade Size
Knockout
1-1/4, 1-1/2 and 2 in.
Typical
Trade Size
Knockout
1/2 in.
Trade Size
Knockout
1/4 in.
15-5/8 in.
Trade Size
Knockout
1/2 in.
Trade Size
Knockout
1/4 in.
1-11/16 in.
9/16 in.
7/8 in.
1-11/16 in.
11/16 in.
1/2 in.
4 in.
1/2 in.
2-1/8 in.
13/16 in.
1-1/16 in.
OVERHEAD BOTTOM
COMBINATION AND
UNDERGROUND BOTTOM
1-3/16 in.
Approved for copper or aluminum
Cat. No.
Description
7 JAW
Overhead, hub opening
PL17-INV
Overhead, hub opening (Hydro-Québec approved)
PL17-INV-HQ
Underground (Hydro-Québec spec)
PL17-INTV-HQ
Combination overhead-underground
PL17-INTCV
Combination overhead-underground (Hydro-Québec approved)
PL17-INTCV-HQ
Overhead, hub opening
PL17-V
Underground
PL17-TV
Combination overhead-underground
PL17-TCV
8 JAW
Overhead, hub opening
PL17-8V
Combination overhead-underground
PL17-8TCV
FACTORY INSTALLED ACCESSORIES
Insulated neutral
Include: -IN
w w w. t n b. c a
H
Dimensions (in.)
W
D
Weight Each
lb.
kg
15-5/8
8-9/16
5-7/16
12
5.4
15-5/8
8-9/16
5-7/16
12
5.4
D11
Meter Sockets
CO1 Series
100 A 120/240 V; Combination with or without Breaker
Product Specifications
•Conductor range (Line and Load): 6-1/0 AWG
•Aluminum tunnel type connectors for both load
and line sides
•For overhead installation
•For underground installation, gutter option must be
ordered (G)
•With factory-installed neutral conductor
•Suitable for 120/240 V single phase service entrance
for mobile homes, trailers, temporary services,
recreational parks and other commercial and
residential locations
•Bottom compartment has provision for 2 pole circuit
breaker (max. 100 A) Siemens (Q), Square D (QO)
•Supplied with screw type rings
•Weatherproof Type 3R enclosure
•Primarily used in: All provinces
(CO1)
4-3/8 in.
Trade Size
Knockout
1-1/4, 1-1/2 and 2 in.
5 Places
5/16 in.
2 in.
4 in.
Trade Size
Knockout
1/2 in.
2 in.
Trade Size
Knockout
1/2 in.
1-13/16 in.
Approved for copper or aluminum
Cat. No.
4 JAW
CO1
CO1-G
CO1-5V
CO1-60
CO1-70
CO1-100
CO1-100G
CO1-100HI
CO1-100HI-G
CO1-SD
CO1-SD-G
Type
Description
Overhead
Underground
Overhead
Overhead
Overhead
Overhead
Underground
Overhead
Underground
Overhead
Underground
Provision for Siemens (Q), 100 A 2 pole 10 kA rated circuit breaker
Provision for Siemens (Q), 100 A 2 pole 10 kA rated circuit breaker, c/w gutter
Provision for Siemens (Q), 100 A 2 pole 10 kA rated circuit breaker, c/w 5th jaw
c/w Siemens Q260 60 A 2 pole 10 kA rated circuit breaker
c/w Siemens Q270 70 A 2 pole 10 kA rated circuit breaker
c/w Siemens Q2100 100 A 2 pole 10 kA rated circuit breaker
c/w Siemens Q2100 100 A 2 pole 10 kA rated circuit breaker, c/w gutter
c/w Siemens Q2100H 100 A 2 pole 22 kA rated circuit breaker
c/w Siemens Q2100H 100 A 2 pole 22 kA rated circuit breaker, c/w gutter
Provision for Square D type “QO” 70 A 2 pole 10 kA rated circuit breaker
Provision for Square D type “QO” 100 A 2 pole 10 kA rated circuit breaker, c/w gutter
H
Dimensions (in.)
W
D
23-1/2
8-1/4
4-3/8
Weight Each
lb.
kg
15
6.8
Note: Some local utilities require a gutter option for underground services. Order with suffix -G.
D12
w w w.t nb.c a
Meter Sockets
CO1 Multi-Gang
200 A (Main lugs), 100 A per position 120/240 V;
Multi-Gang Combination with or without Breaker
Product Specifications
•Conductor range: Line: 6 AWG-250 kcmil,
Load: 6-1/0 AWG
•Overhead only – tunnel type connectors for both
load and line sides
•Underground only – aluminum tunnel type connector load side (6-1/0 AWG), line side 1/2 in. studs
•Supplied with screw type rings
•Weatherproof Type 3R enclosure
•Bottom compartment has provision for 2 pole circuit
breaker (max. 100 A) Siemens (Q), Square D (QO),
Cutler (QR + BR)
•Primarily used in: All provinces
Quebec only: As per Hydro-Québec spec
23-1/2 in.
(supplied with 22 kA Siemens breaker)
4-3/8 in.
(CO12-100HI)
Trade Size
Knockout
1-1/4, 1-1/2 and 2 in.
4 Places
Trade Size
Knockout
1/2, 1-1/4, 1-1/2 and 2 in.
5 Places
15/16 in.
1-15/16 in.
8-5/16 in.
14-1/16 in.
1-15/16 in.
Trade Size
Knockout
1/2 in.
2 Places
2 in.
15/16 in.
4-1/8 in.
Trade Size
Knockout
1/2 in.
2 Places
4-1/8 in.
8-5/16 in.
8-5/16 in.
1-13/16 in.
Approved for copper or aluminum
Cat. No.
4 JAW
CO12
CO12-100
CO12-100HI
CO12-100HI-U
CO12-SD
CO12-SD-U
CO13
CO13-100
CO13-100HI
CO13-100HI-U
CO13-SD
CO13-SD-U
CO14
CO14-100
CO14-100HI
CO14-100HI-U
CO14-SD
CO14-SD-U
Type
Description
Overhead
Overhead
Overhead
Underground
Overhead
Underground
Overhead
Overhead
Overhead
Underground
Overhead
Underground
Overhead
Overhead
Overhead
Underground
Overhead
Underground
2 gang, provision for Siemens 2 x Q2100 100 A 2 pole 10 kA rated circuit breakers
2 gang, c/w Siemens 2 x Q2100 100 A 2 pole 10 kA rated circuit breakers
2 gang, c/w Siemens 2 x Q2100H 100 A 2 pole 22 kA rated circuit breakers
2 gang with blank compartment, c/w Siemens 2 x Q2100H 100 A 2 pole 22 kA rated circuit breakers
2 gang, provision for Square D type “QO” 2 x 100 A 2 pole 10 kA rated circuit breakers
2 gang with blank compartment, provision for Square D type “QO” 2 x 100 A 2 pole 10 kA rated circuit breakers
3 gang, provision for Siemens 3 x Q2100 100 A 2 pole 10 kA rated circuit breakers
3 gang, c/w Siemens 3 x Q2100 100 A 2 pole 10 kA rated circuit breakers
3 gang, c/w Siemens 3 x Q2100H 100 A 2 pole 22 kA rated circuit breakers
3 gang with blank compartment, c/w Siemens 3 x Q2100H 100 A 2 pole 22 kA rated circuit breakers
3 gang, provision for Square D type “QO” 3 x 100 A 2 pole 10 kA rated circuit breakers
3 gang with blank compartment, provision for Square D type “QO” 3 x 100 A 2 pole 10 kA rated circuit breakers
4 gang, provision for Siemens 4 x Q2100 100 A 2 pole 10 kA rated circuit breakers
4 gang, c/w Siemens 4 x Q2100 100 A 2 pole 10 kA rated circuit breakers
4 gang, c/w Siemens 4 x Q2100H 100 A 2 pole 22 kA rated circuit breakers
4 gang with blank compartment, c/w Siemens 4 x Q2100H 100 A 2 pole 22 kA rated circuit breakers
4 gang, provision for Square D type “QO” 4 x 100 A 2 pole 10 kA rated circuit breakers
4 gang with blank compartment, provision for Square D type “QO” 4 x 100 A 2 pole 10 kA rated circuit breakers
Position
Dimensions (in.)
H
W
D
2
16-1/2
Weight Each
lb.
kg
30
13.60
45
20.41
60
27.21
24-3/4
3
23-1/2
4-3/8
33-1/8
33-1/8
4
41-7/16
Note: For underground version, add suffix -U.
w w w. t nb. c a
D13
Meter Sockets
HD1
100 A 120/240 V;
Flat Rate Services Junction Box
Product Specifications
• 100 A, 120/240 V single phase weatherproof junction box for flat
rate services fed underground such as telephone booths, plastic
signs, bus shelters, etc...
• Aluminum tunnel type connector for line side
• Bottom compartment has 2 in., 2-1/2 in., 3 in., 3-1/2 in.
KO’s and 3/8 in. (load side) studs to accommodate compression
lugs (supplied by utility)
• Top compartment has provision for Thomas & Betts, Siemens,
G.E., Westinghouse type “Q” 2 pole breaker
• Weatherproof Type 3R enclosure
• Primarily used in: Quebec only
(HD1)
Trade Size
Knockout
2, 2-1/2,
3 and 3-1/2 in.
1 Place
2-5/8 in.
4-5/16 in.
8-5/8 in.
Approved for copper and aluminum
Cat. No.
HD1
D14
Type
Underground
Dimensions (in.)
Weight Each
H
W
D
lb.
kg
23-1/2
8-5/8
6-1/16
20
9.0
w w w. t n b. c a
Meter Sockets
BQ2 Series
200 A 600 V; Standard Enclosure
Product Specifications
•
•
•
•
•
•
Conductor range: 6 AWG–250 kcmil
Aluminum tunnel type connectors for both load and line sides
For overhead, underground and combination overhead/underground
Supplied with screw type ring
Weatherproof Type 3R enclosure
Primarily used in: All provinces
Note: Supply from an underground network often requires use of stud type connector. Consult your local utility.
5-13/32 in.
(BQ2-V)
Trade Size
Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
2 Places
Trade Size
Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
2 Places
29/64 in.
2-7/32 in.
2-1/4 in.
1-1/32 in.
7/8 in.
K.O. 1/4 in.
4-3/8 in.
2-1/8 in.
3-17/64 in.
COMBINATION AND UNDERGROUND BOTTOM
K.O. 1/2 in.
Trade size
3-3/4 in.
OVERHEAD BOTTOM
1-13/16 in.
5-5/16 in.
Cat. No
Approved for copper and aluminum
Description
4 JAW
Overhead, hub opening
BQ2-V
Overhead, hub opening c/w 1-1/2 in. hub
BQ2-1 1/2 V
Overhead, hub opening c/w 2 in. hub
BQ2-2V
Underground
BQ2-TV
Combination, overhead-underground
BQ2-TCV
Overhead, twin hub opening
BQ2-22VNH
Overhead, twin hub opening c/w 2 in. hubs
BQ2-22V
Overhead, twin hub opening c/w 2 in. hub for B.C
BQ2-2VR
FACTORY INSTALLED ACCESSORIES
Ground lug on neutral
Include: -GN
5th jaw standard capacity
-5
5th jaw full capacity, 6 o’clock position
-6
w w w. t n b. c a
H
Dimensions (in.)
W
D
15-5/8
8-47/64
5-13/32
Weight Each
lb.
kg
12
5.4
D15
Meter Sockets
BP2-TV
200 A 600 V; Standard Enclosure
Product Specifications
•
•
•
•
•
•
Conductor range: 6 AWG–250 kcmil
Aluminum tunnel type connectors for both load and line sides
For underground service only
Supplied with screw type ring
Weatherproof Type 3R enclosure
Primarily used in: Ontario
5-7/16 in.
(BP2-TV)
Trade Size
Knockout
1-1/4, 1-1/2, 2
and 2-1/2 in.
3 Sets
Trade Size
Knockout
1/2 in.
Trade Size
Knockout
1/4 in.
7/16 in.
2-3/16 in.
1-7/8 in.
13/16 in.
3-13/16 in.
3-13/16 in.
2-11/16 in.
12 in.
2-3/8 in.
Approved for copper or aluminum
Cat. No.
BP2-TV
D16
Description
Underground
H
Dimensions (in.)
W
D
20
12
5-7/16
Weight Each
lb.
kg
16.5
7.48
w w w. t n b. c a
Meter Sockets
BS2 Series
200 A 600 V; Oversize Enclosure
Product Specifications
•
•
•
•
•
•
•
Conductor range: 6 AWG-250 kcmil
Aluminum tunnel type connectors for both load and line sides
For overhead, underground and combination overhead/underground
Supplied with screw type ring
Weatherproof Type 3R enclosure
Primarily used in: B.C., AB, Sask., Man., Ont., N.S.
* May be use in all regions
NOTE: Supply from an underground network often requires use of stud type connector.
Consult your local utility.
5-7/16 in.
Trade Size
Knockout
1/2 in.
2 Places
(BS2-V)
Trade Size
Knockout
1-1/4, 1-1/2,
2 and 2-1/2 in.
3 Places
Trade Size
Knockout
1/2 in.
1-7/8 in.
5-3/8 in.
7-5/8 in.
2-1/4 in.
7/8 in.
1/2 in.
1/4 in. K.O.
4-3/16 in.
TYPICAL BOTTOM
Trade Size
Knockout
1, 1-1/4, 1-1/2,
2 and 2-1/2 in.
2 Places
Cat. No.
BC HYDRO BOTTOM
2-1/8 in.
Cuivre et aluminium
2-3/16 in.
Description
4 JAW
Overhead, hub opening
BS2-V
Overhead, hub opening c/w 1-1/2 in. hub
BS2-1 1/2 V
Overhead, hub opening c/w 2 in. hub
BS2-2V
Underground
BS2-TV
Combination, overhead-underground
BS2-TCV
Combination overhead-underground for British Columbia only
BS2-TCVBC
Combination OH and UG (Fortis Alberta approved) c/w 350 kcmil lug
BS2-TCVFA*
Overhead, twin hub opening
BS2-22VNH
Overhead, twin hub opening c/w 2 in. hubs
BS2-22V
Overhead, hub opening c/w 5th jaw, 9 o’clock & insulated neutral
BS2-9-14V
FACTORY INSTALLED ACCESSORIES
5th jaw, standard capacity, 9 o’clock position
Include: -5
5th jaw, full capacity, 6 o’clock position
-6
5th jaw, full capacity, 9 o’clock position
-9
Insulated neutral
-IN
Ground lug on neutral
-GN
w w w. t n b. c a
Trade Size
Knockout
1, 1-1/4, 1-1/2, 2, 2-1/2 and 3 in.
2 Places
H
Dimensions (in.)
W
D
12
5-7/16
Weight Each
lb.
kg
17-1/8
14
6.3
27-7/16
17-1/8
D17
Meter Sockets
BS2 Series Kit
200 A 600 V; Oversize Enclosure
with PVC Accessories
Product Specifications
•
•
•
•
•
•
Conductor range: 6 AWG-250 kcmil
Aluminum tunnel type connectors for both load and line sides
For overhead, underground and combination
Supplied with screw type ring
Weatherproof Type 3R enclosure
Primarily used in: Ontario only
Note: Supply from an underground network often requires use of stud type connector.
Consult your local utility.
5-7/16 in.
(BS2-TCV-KIT2U)
Trade Size
Knockout
1-1/4, 1-1/2,
2 and 2-1/2 in.
3 Places
Trade Size
Knockout
1/2 in.
2-1/8 in.
1-7/8 in.
5-3/8 in.
7-5/8 in.
2-1/4 in.
7/8 in.
1/2 in.
1/4 in. K.O.
TYPICAL BOTTOM
Cat. No.
KIT
BS2-TCV-KIT2U
Consists of
BS2-TCV
E943J
E986J
E995J
E997JC
UA9AJCB-CTN
CI1716
PH20
D18
2-3/16 in.
Trade Size Knockout
1, 1-1/4, 1-1/2, 2 and 2-1/2 in.
2 Places
Description
Approved for copper or aluminum
Qty.
Kit – Meter socket with PVC accessories
200 A meter socket
2 in. terminal adaptor
2 in. LB access fitting
2 in. meter offsets
2 in. clamps
2 in. elbow 90 degree
2 in. nut
2 in. hub
1
2
1
3
1
w w w. t n b. c a
Meter Sockets
BS2-TCVFA
200 A, 120/240; Single Phase Service
Product Specifications
•
•
•
•
•
•
Line: #6 AWG to 350 kcmil, Load 2 x #6 AWG – 4/0
Tunnel type connectors for both load and line sides
For underground and above ground service
Weatherproof Type 3R enclosure
Designed and manufactured in Canada
Primarily used in: All provinces
Application: When distance is a factor larger conductors require larger connectors.
5-7/16 in.
1-1/32 in.
12 in.
1.475 in.
2.5 in. 3.32 in.
27-7/16 in.
1-1/4 in., 1-1/2 in., 2 in., 2-1/2 in.
TTrade size K.O. 3-Places
1/2 in. Trade size K.O.
O
10.61 in.
2-1/8 in.
2-1/4 in.
1 in., 1-1/4 in., 1-1/2 in., 2 in.,
2-1/2 in. Trade size K.O.’s
2 Places
7/8 in.
1-7/8 in.
7-5/8 in.
5-3/8 in.
1/4 in. K.O.
1/
5-7/8 in.
Approved for copper and aluminum
Cat. No.
4 JAW
BS2-TCVFA
w w w. t n b. c a
Description
Combination overhead and underground 200 A service
H
Dimensions (in.)
W
D
27-7/16
12
5-7/16
Weight Each
lb.
kg
14
6.3
D19
Meter Sockets
BS2L Series
200 A 600 V; Oversize Enclosure Lay-In Lug
Product Specifications
•
•
•
•
•
•
•
Same as BS2 Series with the exception that lay-in type connectors are provided
Conductor range: 6 AWG-250 kcmil
Aluminum lay-in type connectors for both load and line sides
For overhead, underground and combination overhead/underground
Supplied with screw type ring
Weatherproof Type 3R enclosure
Primarily used in: B.C., Ont.
5-7/16 in.
(BS2L-TV)
Trade Size Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
3 Places
Trade Size
Knockout
1/2 in.
1-7/8 in.
5-3/8 in.
7-5/8 in.
2-1/4 in.
7/8 in.
1/2 in.
1/4 in.
TYPICAL BOTTOM
Trade Size Knockout
1/2 in., 2 Places
Trade Size Knockout
1, 1-1/4, 1-1/2, 2, 2-1/2 and 3 in.
2 Places
2-9/16 in.
1-3/16 in.
1/2
/ in.
1/4 in.
4-3/16 in.
4-3/4 in.
9-7/8 in.
2-1/8 in.
BC HYDRO BOTTOM
2-3/16 in.
Trade Size Knockout
1, 1-1/4, 1-1/2, 2 and 2-1/2 in.
2 Places
Approved for copper or aluminum
Cat. No.
Description
4 JAW
200 A overhead with lay-in lugs
BS2L-V
200 A underground with lay-in lugs
BS2L-TV
200 A over/under combination with lay-in lugs
BS2L-TCV
200 A over/under combination with lay-in lugs (BC)
BS2L-TCVBCR
200 A over/under combination water heater lugs
BS2L-WTCV
200 A over/under combination with water heater lugs and North York assembly
BS2L-WTCVNY
FACTORY INSTALLED ACCESSORIES
5th jaw standard capacity
Include: -5
5th jaw full capacity, 6 o’clock position
-6
5th jaw full capacity, 9 o’clock position
-9
Insulated neutral
-IN
North York assembly
-NY
Water heater lugs
-W
D20
H
Dimensions (in.)
W
D
17-1/8
12
5-7/16
Weight Each
lb.
kg
16
7.2
w w w. t n b. c a
Meter Sockets
BS2M Series
200 A 600 V; Oversize Enclosure,
Subfeed on Load Side
Product Specifications
•
•
•
•
•
•
•
Conductor range: Line: 6 AWG-250 kcmil, Load: 12-1/0 AWG
Aluminum tunnel type connector for line side
For overhead service only
Dual lug subfeed for load side
Supplied with screw type ring
Weatherproof Type 3R enclosure
Primarily used in: All provinces
(BS2M-V)
5-7/16 in.
Trade Size
Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
3 Places
Trade Size
Knockout
1/2 in.
2-1/4 in.
7/8 in.
1/2 in.
1-7/8 in.
5-3/8 in.
7-5/8 in.
Trade Size
Knockout
1/4 in.
BOTTOM
2-1/8 in.
2-3/16 in.
Trade Size
Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
2 Places
Approved for copper or aluminum
Cat. No.
Description
4 JAW
BS2M-V
Overhead, hub opening
w w w. t n b. c a
H
Dimensions (in.)
W
D
17-1/8
12
5-7/16
Weight Each
lb.
kg
15
6.8
D21
Meter Sockets
BS4M
200 A 600 V; Oversize Enclosure,
Subfeed on Load Side
Product Specifications
•Conductor range: Line: 6 AWG-250 kcmil Load: 6-4/0 AWG
•Aluminum tunnel type connectors for both line and load sides
•For overhead service only
•Dual lug subfeed connectors for load side
•Weatherproof Type 3R enclosure
•Primarily used in: Manitoba
5-7/16 in.
(BS4M-V)
Trade Size
Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
3 Places
Trade Size
Knockout
1/2 in.
Trade Size
Knockout
1/2 in.
1/2 in.
2-1/4 in.
1-9/16 in.
1-7/8 in.
3-13/16 in.
2-1/8 in.
3-13/16 in.
Trade Size
Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
3 Places
Cat. No.
BS4M-V
D22
Description
Overhead hub opening
2-3/16 in.
H
Dimensions (in.)
W
D
17
12
5-7/16
Weight Each
lb.
kg
14.95
6.75
w w w.t nb.c a
Meter Sockets
MO2 Series
200 A 600 V; Underground Only
Product Specifications
•Conductor Range: Line: Single 1/2 in. studs to accommodate compression lugs
350 kcmil max. (supplied by utility), Load: 6 AWG-250 kcmil
•For underground service only
•Aluminum tunnel type connectors for load side, 1/2 in. studs on line side
•Supplied with screw type ring
•Weatherproof Type 3R enclosure
•Primarily used in: Sask., Man., Ont., Que.
(MO2-V)
9-5/16 in.
Trade Size
Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
3 Places
7/8 in.
Trade Size
Knockout
1, 1-1/4, 1-1/2, 2, 2-1/2 and 3 in.
2 Places
Trade Size
Knockout
7/8 in.
2 Places
19-1/8 in.
1-7/8 in.
4-3/16 in.
5-3/8 in.
7-5/8 in.
4-3/4 in.
1/4 in.
1/4 in.
9-7/8 in.
MO2-VO BOTTOM
MO2-V BOTTOM
2 in.
2-5/16 in.
Approved for copper or aluminum
Cat. No.
Description
4 JAW
Underground 1/2 in. studs
MO2-V
Underground 1/2 in. studs for Ontario
MO2-VO
FACTORY-INSTALLED ACCESSORIES
Water heater lugs
Include:-W
2/0 AWG subfeed on load side
-M
w w w. t nb. c a
H
Dimensions (in.)
W
D
19-1/8
12
9-5/16
Weight Each
lb.
kg
18
8.1
D23
Meter Sockets
MO2 Series Kit
200 A 600 V; Underground Only with
PVC Accessories
Product Specifications
• Conductor range: Line: Single 1/2 in. studs to accommodate
compression lugs (supplied by utility), Load: 6 AWG-250 kcmil
• For underground service only
• Aluminum tunnel type connectors for load side
• Supplied with screw type ring
• Weatherproof Type 3R enclosure
• Primarily used in: Ontario Only
5-9/16 in.
(MO2-VO-KIT2U)
Trade Size
Knockout
1, 1-1/4, 1-1/2, 2, 2-1/2 and 3 in.
3 Places
7/8 in.
19-1/8 in.
1-7/8 in.
5-3/8 in.
1/4 in.
7-5/8 in.
2 in.
MO2-VO BOTTOM
2-5/16 in.
Approved for copper or aluminum
Cat. No.
KIT
MO2-VO-KIT2U
Consists of
MO2-VO
CI1716
E943J
E977JC
E986J
E995J
UA9AJCB-UPC
D24
Description
Qty.
Kit – Meter socket with PVC accessories
200 A Meter Socket
2 in. Locknut
2 in. Male Adaptor
2 in. Pipe Strap
2 in. Conduit Bodies – LB Type
2 in. Meter Offsets
2 in. 90o Elbow
1
3
1
2
1
2
1
w w w. t n b. c a
Meter Sockets
MO2 Series Kit
200 A 600 V; Underground Only with
PVC Accessories
Product Specifications
• Conductor range: Line: Single 1/2 in. studs to accommodate
compression lugs (supplied by utility), Load: 6 AWG-250 kcmil
• For underground service only
• Aluminum tunnel type connectors for load side,
1/2 in. studs on line side
• Supplied with screw type ring
• Weatherproof Type 3R enclosure
• Primarily used in: Quebec Only
5-9/16 in.
(MO2-V-KIT1-1/4U)
Trade Size
Knockout
1, 1-1/4, 1-1/2, 2, 2-1/2 and 3 in.
2 Places
Trade Size
Knockout
7/8 in.
2 Places
19-1/8 in.
4-3/16 in.
4-3/4 in.
2 in.
9-7/8 in.
1/4 in.
MO2-V BOTTOM
Approved for copper or aluminum
2-5/16 in.
Cat. No.
KIT
MO2-V-KIT1-1/4U
Consists of
MO2-V
CE942RL
CI1710
CI1724
CI-DUCT-1
E943G
E943L
E945L
E977GC
E977LC-CAR
E986G
UA9AGCB-UPC
w w w. t n b. c a
Description
Qty.
Meter socket with PVC accessories
200 A Meter Socket
3 in. PVC/DB2 Adaptor
1-1/4 in. nut
3 in. nut
Duct Seal
1-1/4 in. Male Adaptor
3 in. Male Adaptor
3 in. Expansion Fitting
1-1/4 in. Pipe Strap
3 in. Pipe Strap
1-1/4 in. Conduit Bodies – LB Type
1-1/4 in. 90o Elbow
1
2
1
2
1
Cat. No.
KIT
MO2-V-KIT2U
Consists of
MO2-V
CE942RL
CI1716
CI1724
CI-DUCT-1
E943J
E943L
E945L
E977JC
E977LC-CAR
E986J
UA9AJCB-UPC
Description
Qty.
Meter socket with PVC accessories
200 A Meter Socket
3 in. PVC/DB2 Adaptor
2 in. nut
3 in. nut
Duct Seal
2 in. Male Adaptor
3 in. Male Adaptor
3 in. Expansion Fitting
2 in. Pipe Strap
3 in. Pipe Strap
2 in. Conduit Bodies – LB Type
2 in. 90o Elbow
1
2
1
2
1
D25
Meter Sockets
BD2 Series
200 A (Main Lugs) 600 V;
Multiple Position – 200 A per Position
Product Specifications
•Conductor range: Line: 6 AWG-250 kcmil, Load: 6 AWG-250 kcmil
•Aluminum tunnel type connectors for both load and line sides
•Factory prebussed from main lugs to each position
•Supplied with hub opening closure plate for underground service
•Combination overhead underground
•Supplied with screw type rings
•Weatherproof Type 3R enclosure
•Primarily used in: All provinces
(BD2-V)
Trade Size
Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
Typical
Trade Size
Knockout
1/2 in.
2 Places
Trade Size
Knockout
1-1/2, 2, 2-1/2 and 3 in.
Typical
2-1/4 in.
2-1/16 in.
H
1-3/16 in.
4-5/16 in.
8-3/4 in.
Steps
8-3/4 in.
8-3/4 in.
2-1/2 in.
2-7/16 in.
2-1/4 in.
1-3/16 in.
1-3/16 in.
2-3/16 in.
4-3/8 in.
5-7/16 in.
Steps
8-3/4 in.
1-3/16 in.
Trade Size
Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
4 Places
Note: Pattern for bottoms. Left hand entry is shown. For right-hand entry, unit is manufactured
symmetrically with hub openings, knockout and line connections on right side.
Meter Position
Cat. No.
4 JAW
LEFT-HAND ENTRY
BD2-V
BD3-V
BD4-V
BD2-VBC
D26
RIGHT-HAND ENTRY
BD2-VH
BD3-VH
BD4-VH
BD2-VBCH
2 position
3 position
4 position
2 position for British Columbia
Approved for copper or aluminum
H
15-1/2
20
Dimensions (in.)
W
17-1/2
26-1/4
35
17-1/2
D
5-7/16
Weight Each
lb.
kg
23
35
47
27
10.4
15.9
21.3
12.2
w w w.t nb.c a
Meter Sockets
BDA2-V Series
200 A (Main Lugs) 600 V; Multiple Position with
Blank Compartment 200 A per position
Product Specifications
•
•
•
•
•
•
•
Conductor range: Line: 6 AWG-250 kcmil, Load: 6 AWG-250 kcmil
Aluminum tunnel type connectors for load side
Combination overhead and underground
Hub opening closure plate for underground service
Supplied with screw type rings
Weatherproof Type 3R enclosure
Primarily used in: Ontario only
(BDA2-V)
D
H
Trade Size
Knockout
1-1/4, 1-1/2, 2,
2-1/2 and 3 in.
2 Places
Trade Size
Knockout
1/4 in.
2 Places
8-11/16 in.
4-5/16 in.
4-5/16 in.
2-1/2 in.
2-1/2 in.
1-1/4 in.
2-3/8 in.
7/8 in.
2-11/16 in.
5-9/16 in.
Trade Size
Knockout
1-1/2, 2,
2-1/2 and 3 in.
2 Places
1-1/4 in.
2-1/4 in.
Approved for copper or aluminum
Cat. No.
Meter Position
H
Dimensions (in.)
W
D
15-5/8
26-3/16
5-1/4
Weight Each
lb.
kg
4 JAW
LEFT-HAND ENTRY
BDA2-V
w w w. t n b. c a
RIGHT-HAND ENTRY
BDA2-VH
2 position
31
14.6
D27
Meter Sockets
BDC Series
200 A (Main Lugs) 600 V; Stud Type
Multiple Position with Blank Compartment
200 A per Position
Product Specifications
•Conductor Range: Line: Single 1/2 in. studs to accommodate
compression lugs (supplied by utility), Load: 6 AWG-250 kcmil
•Aluminum tunnel type connectors for load sides
•For underground service only
•Factory prebussed from main lugs to each position
•Supplied with screw type sealing rings
•Weatherproof Type 3R enclosure
•Primarily used in: All provinces
(BDC2-VIL)
Trade Size K.O.’s
1/2 in.
2 Places
2-7/16 in.
1-9/16 in.
Trade Size K.O.’s
1-1/4, 1-1/2, 2 and 2-1/2 in.
Typical
Trade Size K.O.’s
1-1/2, 2, 2-1/2 and 3 in.
Typical
2-1/4 in.
1-3/16 in. 2-7/16 in.
1-1/8 in.
4-5/16 in.
13-1/8 in.
Typical
Trade Size K.O.’s
1-1/2, 2, 2-1/2
and 3 in.
Typical
4-3/8 in.
Typical
Trade Size K.O.’s
1/2 in.
2 Places
4-3/8 in. 1-3/16 in.
Typical
15-5/8 in.
Trade Size K.O.’s
1-1/4, 1-1/2, 2 and 2-1/2 in.
Typical
2-3/16 in.
1-1/16 in. 2-5/16 in.
2-5/16 in.
2-5/8 in.
5-1/2 in.
Note: Pattern for bottoms. Left hand entry is shown.
For right-hand entry, unit is manufactured symmetrically
with hub openings, knockouts for line connectors on right side.
4-5/16 in. 4-7/16 in.
Typical
Typical
8-3/4 in.
Typical
13-1/8 in.
Typical
1-3/16 in.
2-3/16 in.
Copper or aluminum
For use in All Provinces
Cat. No.
Left-Hand
Entry
Right-Hand
Entry
4 JAW
BDC2-V
BDC3-V
BDC4-V
BDC2-VH
BDC3-VH
BDC4-VH
Meter
Position
Dimensions (in.)
H
W
Weight Each
D
2 position
26-1/4
3 position 15-5/8 35 5-1/4
4 position
43-3/4
lb.
kg
30
42
54
13.6
19.0
24.5
4 JAW
BDC2-VIL
BDC3-VIL
BDC4-VIL
Right-Hand
Entry
Copper or aluminum
Meter
Position
Dimensions (in.)
H
W
D
4 JAW
BDC2-VAILBC BDC2-VAHILBC 2 position
26-1/4 5-1/4
BDC3-VAILBC BDC3-VAHILBC 3 position 20-3/4
35
BDC4-VAILBC BDC4-VAHILBC 4 position
Locking system inside meter section, comes with tunnel type connector on line side.
D28
Right-Hand
Entry
BDC2-VHIL
BDC3-VHIL
BDC4-VHIL
Meter
Position
Dimensions (in.)
Weight Each
H
lb.
kg
30
42
54
13.6
19.0
24.5
W
D
2 position
26-1/4
3 position 15-5/8 35 5-1/4
4 position
43-3/4
Locking system inside meter section.
For use in British Colombia
Left-Hand
Entry
Copper or aluminum
For use in Quebec Cat. No.
Left-Hand
Entry
Locking system outside meter section.
Cat. No.
2-1/2 in.
Weight Each
lb.
kg
30
13.6
42
19.0
Copper or aluminum
For use in Ontario
Cat. No.
Left-Hand
Entry
5 JAW
BDC2-5V
BDC3-5V
BDC4-5V
Dimensions (in.)
Meter
Position
2 position
3 position
4 position
Weight Each
H
W
D
lb.
kg
15-5/8
26-1/4
35
43-3/4
5-1/4
30
42
54
13.6
19.0
24.5
Locking system outside meter section.
w w w.t nb.c a
Meter Sockets
BS4 Series
400 A (Main Lugs) 600 V; Multiple Position with
Blank Compartment 200 A per Position
Product Specifications
• Conductor range: Line: Dual rated connectors for 1 x 4 AWG-600 kcmil
or 2 x 1/0 AWG-250 kcmil, Load: 6 AWG-250 kcmil
• Aluminum tunnel type connectors for both load and line sides
• Factory prebussed from main lugs to each position
• Combination overhead-underground
• Supplied with hub opening closure plate for underground service
• Larger hub opening requires use of 3 in. , 3-1/2 in. or 4 in.
hubs unless BS052 adapter plate is used
• Supplied with screw type rings
• Weatherproof Type 3R enclosure
• Primarily used in: All provinces
(BS42-V)
Tunnel type connector
1/2 in. Stud
Connection
Compression Lug
5-5/16 in.
TUNNEL TYPE CONNECTOR
TERMINATION LOAD AND LINE
Trade Size
Knockout
2, 2-1/2, 3
and 3-1/2 in.
1 Place
23-3/8 in.
Trade Size
Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
Typical
Trade Size
Knockout
1/2 in.
1 Place
COMPRESSION LUG TERMINATION
(WITH STUD CONNECTION)
500 KCMIL MAX. UNDERGROUND
APPLICATION COMPRESSION
CONNECTOR SUPPLIED BY UTILITY.
Trade Size
Knockout
1-1/4, 1-1/2, 2
and 2-1/2 in.
Typical
Trade Size
Knockout
2, 2-1/2, 3
and 3-1/2 in.
1 Place
2-7/8 in.
2-3/8 in.
Trade Size
Knockout
1/2 in.
1 Place
1-1/8 in.
4-5/16 in.
13-1/16 in.
8-3/4 in.
8-3/4
4-5/16 in.
13-1/16 in.
8-3/4 in.
8-3/4 in.
Approved for copper or aluminum
Cat. No.
4 JAW
LEFT-HAND ENTRY
BS42-V
BS43-V
BS44-V
BS45-V
BS46-V
w w w. t n b. c a
Meter Position
RIGHT-HAND ENTRY
BS42-VH
BS43-VH
BS44-VH
BS45-VH
BS46-VH
2 position
3 position
4 position
5 position
6 position
H
23-3/8
Dimensions (in.)
W
26-1/4
35
43-3/4
52-1/2
61-1/4
D
5-5/16
Weight Each
lb.
kg
45
59
73
87
101
20.4
26.8
33.1
39.5
45.9
D29
Meter Sockets
BSC4-G Series
400 A (Main Lugs) 600 V; Stud Type Multiple Position
with Blank Compartment 200 A per Position
Product Specifications
• Conductor range: Line: Single 1/2 in. studs to accommodate compression
lugs (supplied by utility), Load: 6 AWG-250 kcmil
• Aluminum tunnel type connectors for load side
• For underground service only
• Twin wiring compartment, increased length of the busbars and double
1/2 in. studs to accommodate compression lugs
• Supplied with screw type rings
• Weatherproof Type 3R enclosure
• Primarily used in: Ontario and British Columbia
(BSC42-VGA)
Trade Size
Knockout
1/2 in.
1 Place
Trade Size
Knockout
2, 2-1/2, 3 and 3-1/2 in.
1 Place
Trade Size
Knockout
1-1/4, 1-1/2, 2 and 2-1/2 in.
Typical
20-1/8 in.
2-3/8 in. 2-15/16 in.
1-1/4 in.
1-1/4 in.
4-3/8 in.
13-1/8 in.
8-3/4 in.
8-3/4 in.
6-3/8 in.
Approved for copper or aluminum
For use in Ontario
Cat. No.
Left-Hand Entry
BSC42-VG
BSC43-VG
BSC44-VG
BSC45-VG
BSC46-VG
Right-Hand Entry
BSC42-VGH
BSC43-VGH
BSC44-VGH
BSC45-VGH
BSC46-VGH
Meter Position
Dimensions (in.)
H
2 position
Weight Each
D
35
3 position
4 position
W
43-3/4
23-3/8
52-1/2
5-5/16
Cat. No.
D30
Right-Hand Entry
BSC42-VGAH
BSC43-VGAH
BSC44-VGAH
BSC45-VGAH
BSC46-VGAH
kg
58
26.3
72
32.7
86
39.0
5 position
61-1/4
100
45.4
6 position
70
114
51.8
Approved for copper or aluminum
For use in British Columbia
Left-Hand Entry
BSC42-VGA
BSC43-VGA
BSC44-VGA
BSC45-VGA
BSC46-VGA
lb.
Meter Position
Dimensions (in.)
H
2 position
Weight Each
D
35
3 position
4 position
W
43-3/4
23-3/8
52-1/2
5-5/16
lb.
kg
58
26.3
72
32.7
86
39.0
5 position
61-1/4
100
45.4
6 position
70
114
51.8
w w w. t n b. c a
Meter Sockets
PL27 Series
200 A 600 V; Polyphase
Product Specifications
•
•
•
•
Conductor range: 6 AWG-250 kcmil
Tunnel type connector for both load and line sides
For overhead and combination overhead/underground service
Larger hub opening requires use of 3 in., 3-1/2 in. or 4 in. hubs
unless BS052 adapter plate is used
• Supplied with screw type ring
• Weatherproof Type 3R enclosure
• Primarily used in: All provinces
5-7/16 in.
(PL27-V)
Trade Size
Knockout
1/4 in.
Trade Size Knockout
1-1/2, 2, 2-1/2 and 3 in.
2 Places
1/2 in.
2-9/16 in.
1-3/16 in.
1-3/4 in.
Trade Size
Knockout
1/2 in.
Trade Size
Knockout
1-1/2, 2, 2-1/2
and 3 in.
2 Places
Trade Size Knockout
1-1/2, 2, 2-1/2 and 3 in.
2 Places
Trade Size
Knockout
1/2 in.
2-3/8 in.
2-11/16 in.
4-3/4 in.
2-3/8 in.
Trade Size
Knockout
1/2 in.
15/16 in.
15/16 in.
1-11/16 in.
5/16 in.
Trade Size
Knockout
1/4 in.
5-5/16 in.
Cat. No.
Description
Approved for copper or aluminum
H
Dimensions (in.)
W
D
20-1/8
12
5-7/16
Weight Each
lb.
kg
7 JAW
PL27-V
Overhead hub opening
PL27-TCV
Combination overhead-underground
PL27-IN-V
Overhead hub opening, Insulated neutral
PL27-IN-TCV
Combination overhead-underground, Insulated neutral
w w w. t n b. c a
18
8.1
D31
Meter Sockets
CO2 Series
200 A 120/240 V; Combination with or without Breaker
Product Specifications
•Conductor range (Line and Load): 1 AWG-250 kcmil
•Aluminum tunnel type connectors for both load and line sides
•For overhead and underground services
•With factory-installed neutral conductor
•Suitable for 120/240 V single phase service entrance for mobile homes,
trailers, temporary services, recreational parks and other commercial 5-7/16 in.
and residential locations
•Factory installed 2 pole circuit breaker, 10,000 A rms
interrupting capacity
•With adjustable bracket for field installation to
accept Cutler Hammer (ED, EDH) breakers
• “QJ” Type Siemens breaker
•Supplied with screw type rings
•Weatherproof Type 3R enclosure
•Primarily used in: All provinces
Quebec only: As per Hydro-Québec spec
(supplied with 22 kA Siemens breaker)
32-3/4 in.
(CO2-200)
7-5/8 in.
CAT. NO.: CO3417M-1-FG
Trade Size
Knockout
1-1/4, 1-1/2,
2 and 2-1/2 in.
6 Places
Trade Size
Knockout
1/4 in.
1 Place
7/8 in.
2-1/4 in.
1/2 in.
4-1/6 in.
Trade Size
Knockout
1/2 in.
1 Place
2-3/16 in.
2-1/4 in.
9/16 in.
Approved for copper or aluminum
Type
Description
4 JAW
CO2
CO2-125
CO2-125-5V
CO2-125HI
CO2-150
CO2-150-5V
CO2-150HI
CO2-200
CO2-200-5V
CO2-200HI
CO2-200G
CO2-200GM
CO2-G
Overhead
Overhead
Overhead
Overhead
Overhead
Overhead
Overhead
Overhead
Overhead
Overhead
Underground
Underground
Underground
CO2-GMB
Underground
Provision for Siemens (QJ), 200 A 2 pole 10 kA rated circuit breaker
c/w Siemens QJ 125 A 2 pole 10 kA rated circuit breaker
c/w Siemens QJ 125 A 2 pole 10 kA rated circuit breaker, c/w 5th jaw
c/w Siemens QJH 125 A 2 pole 22 kA rated circuit breaker
c/w Siemens QJ 150 A 2 pole 10 kA rated circuit breaker
c/w Siemens QJ 150 A 2 pole 10 kA rated circuit breaker, c/w 5th jaw
c/w Siemens QJH 150 A 2 pole 22 kA rated circuit breaker
c/w Siemens QJ 200 A 2 pole 10 kA rated circuit breaker
c/w Siemens QJ 200 A 2 pole 10 kA rated circuit breaker, c/w 5th jaw
c/w Siemens QJH 200 A 2 pole 22 kA rated circuit breaker
c/w Siemens QJ 200 A 2 pole 10 kA rated circuit breaker, c/w gutter
c/w Siemens QJ 200 A 2 pole 10 kA rated circuit breaker and adjustable bracket, c/w gutter
Provision for Siemens (QJ), 200 A 2 pole 10 kA rated circuit breaker, c/w gutter
Atco, Alberta; provision for Siemens (QJ), Cutler Hammer (ED, EDH), 200 A 2 pole
10 kA rated circuit breaker, c/w pole mount kit, 2 x 3306 connectors, c/w gutter
Cat. No.
H
Dimensions (in.)
W
D
32-3/4
11-13/16
Weight Each
lb.
kg
28
12.7
30
13.6
32.6
30
14.6
13.6
28
12.7
5-7/16
Note: Some local utilities require a gutter option for underground services. Order with suffix -G.
Please check with local supply authority if mechanical connectors are accepted for underground services.
D32
w w w.t nb.c a
Meter Sockets
CO2M Series
200 A – Single Phase 120/240 V;
Combination with or without Breaker and Splitter
Product Specifications
•Conductor range (Line and Load): 6 AWG-250 kcmil
•Tunnel type connectors for both load and line sides
•For combination overhead/underground service only
• Cutler Hammer (ED, EDH) breaker to be field-installed
• With CO2FB braid connector (also available for field installation cat. no.: CO2FB-KIT)
•Primarily used in: Alberta
5-7/16 in.
Trade Size
Knockout
1-1/2 and 2 in.
2 Places
3-3/8 in.
7/16 in.
Trade Size
Knockout
1/2, 3/4,
1 and 1-1/4 in.
3 Places
2 in.
1-11/16 in.
1-11/16 in.
1-1/2 in.
9/16 in.
4-3/8 in.
4-3/16 in.
Trade Size
Knockout
1/4 in.
2 Places
(C02M)
3-7/8 in.
2-3/4 in.
1/2 in. 2-11/16 in.
CO2MS
3-13/16 in.
Trade Size
Knockout
1-1/4, 1-1/2,
2 and 2-1/2 in.
5 Places
3-13/16 in.
Trade Size
Knockout
1/2 in.
1 Place
CAT. NO.: CO2FB-KIT
2-1/4 in.
1/2 in.
7/8 in.
1-7/8 in.
2-5/8 in.
Trade Size
Knockout
1/4 in.
1 Place
5-15/16 in.
9/16 in.
CO2M
2-3/16 in.
Type
Cat. No.
Description
Approved for copper or aluminum
H
Dimensions (in.)
W
D
Weight Each
lb.
kg
4 JAW
CO2M
CO2MS
CO2MS-1 1/4
Combination
OH/UG
CO2MS-2446
CO2MSB-200
CO2MSU
Underground
Provision for field-installed Cutler Hammer (ED, EDH) 200 A 2 pole 10 kA rated circuit breaker,
provision for pole mounting (splitter not included)
Provision for field-installed Cutler Hammer (ED, EDH) 200 A 2 pole 10 kA rated circuit breaker,
provision for pole mounting (splitter included)
Provision for field-installed Cutler Hammer (ED, EDH) 200 A 2 pole 10 kA rated circuit breaker,
provision for pole mounting, c/w 1-1/4 hub (splitter included)
Provision for field-installed Cutler Hammer (ED, EDH) 200 A 2 pole 10 kA rated circuit breaker,
provision for pole mounting, c/w 2446 connector (splitter included), Fortis Alberta approved
c/w Siemens QJ 200 A 2 pole 10 kA rated circuit breaker, c/w neutral bar (splitter included)
Provision for field-installed Cutler Hammer (ED, EDH) 200 A 2 pole 10 kA rated cicuit breaker,
pedestal type for padmount applications (splitter included)
30-5/8
39-3/8
60
12
28
12.7
42
19
44
19.5
47
21.3
59
26.8
5-7/16
Note: Mounting brackets are now shipped unassembled inside each unit where applicable.
w w w. t nb. c a
D33
Meter Sockets
CO22 Series
200 A (Main Lugs), 200 A per Position, Single Phase 120/240 V;
Multiple Position Comb ination with or without Breaker
Product Specifications
•Conductor range: Line: 6 AWG-250 kcmil, Load: 6 AWG-250 kcmil
•Aluminum tunnel type connectors for both load and line sides
•For overhead and underground services
•Factory pre-bussed from main lugs to each position
•Supplied with hub opening closure plate for underground service
•Internal locking system for covers
•Supplied with screw type sealing rings
•Factory installed 2 pole circuit breaker, 10,000 A rms interrupting capacity
•Siemens Type “QJ” breaker
•With adjustable breaker plate for field installation of Square D and Eaton breakers
•Weatherproof Type 3R enclosure
•Primarily used in: All provinces,
Quebec only: As per Hydro-Québec spec
5-1/2 in.
(supplied with 22 kA Siemens breaker)
C
H
Note: Consult your Regional Sales Office for right-hand entry option.
1-7/16 in.
Trade Size
Knockout
1-1/2, 2,
2-1/2 and 3 in.
1 Place
Trade Size
Knockout
1/2 in.
2 Places
Trade Size
Knockout
1-1/4, 1-1/2,
2 and 2-1/2 in.
4 Places
1-7/16 in.
1-9/16 in.
7-1/8 in.
2-1/4 in.
2-7/16 in.
1-3/16 in.
1-1/8 in.
4-5/16 in.
Hub
Cat. No.
MH10X
MH12X
MH15
MH20
MH25
4-3/8 in.
8-3/8 in.
30 in.
26-15/16 in.
Hub
C
H
Size
(in.)
(in.)
1
1-7/16 1-1/8
1-1/4 1-5/8 1-1/32
1-1/2 1-11/16 1-1/32
2
1-15/16 1-1/32
2-1/2 2-1/8 1-7/16
Approved for copper or aluminum
Cat. No.
Type
Left-Hand Entry
CO22
CO22-200
CO22-200HI
CO23
Combination
CO23-200
OH/UG*
CO23-200HI
CO24
CO24-200
CO24-200HI
Description
2 gang, provision for Siemens 2 x (QJ), 200 A 2 pole 10 kA rated circuit breakers
2 gang, c/w Siemens 2 x QJ 200 A 2 pole 10 kA rated circuit breakers
2 gang with blank compartment, c/w Siemens 2 x QJH 200 A 2 pole 22 kA rated circuit breakers
3 gang, provision for Siemens 3 x (QJ), 200 A 2 pole 10 kA rated circuit breakers
3 gang, c/w Siemens 3 x QJ 200 A 2 pole 10 kA rated circuit breakers
3 gang with blank compartment, c/w Siemens 3 x QJH 200 A 2 pole 22 kA rated circuit breakers
4 gang, provision for Siemens 4 x (QJ), 200 A 2 pole 10 kA rated circuit breakers
4 gang, c/w Siemens 4 x QJ 200 A 2 pole 10 kA rated circuit breakers
4 gang with blank compartment, c/w Siemens 4 x QJH 200 A 2 pole 22 kA rated circuit breakers
Position
Dimensions (in.)
H
W
D
2
3
4
30
Weight Each
lb.
kg
17-1/2
40
26-1/4
60
27.21
26-1/2
60
27.21
35
80
36.29
35-1/4
80
36.28
43-3/4
100 45.36
5-1/2
18.14
Note: Ex. CO22-XXX, suffix (XXX) can be replaced by any of the following breaker amperage options: 100, 125 or 150. Consult your Regional Sales Office for price and availability.
*Only allowed for underground use if local utility authority does not require a blank compartment. If blank compartment is required, recommend CO22-U.
D34
w w w.t nb.c a
Meter Sockets
CO22-U Series
200 A (Main Lugs), 200 A per Position, Single Phase 120/240 V;
Multiple Position Combination with Compartment
with or without Breaker
Product Specifications
•Conductor range: Line: Single 1/2 in. stud to accommodate compression lugs
(supplied by utility), Load: 6 AWG-250 kcmil
•Aluminum tunnel type connectors for load sides
•For underground service only
•Factory pre-bussed from main lugs to each position
• Internal locking system for covers
• Supplied with screw type sealing rings
• Factory installed 2 pole circuit breaker, 10,000 A rms interrupting capacity
•Siemens Type “QJ” breaker
• With adjustable breaker plate for field installation of Square D and Eaton breakers
• Weatherproof Type 3R enclosure
•Primarily used: All Provinces
Quebec only: As per Hydro-Québec spec (supplied with 22 kA Siemens breaker)
Note: Consult your Regional Sales Office for right-hand entry option.
8-13/16 in.
1-7/16 in.
1-7/16 in.
5-1/2 in.
1-9/16 in.
7-1/8 in.
30 in.
26-15/16 in.
Trade Size
Knockout
1-1/2, 2,
2-1/2 and 3 in.
2 Places
Trade Size
Knockout
1/2 in.
2 Places
2-7/16 in.
1-3/16 in.
1-3/16 in.
Trade Size
Knockout
1-1/4, 1-1/2,
2 and 2-1/2 in.
4 Places
2-1/4 in.
4-5/16 in.
8-3/4 in.
4-3/8 in.
8-3/4 in.
Approved for copper or aluminum
Cat. No.
Type
Description
Position
Dimensions (in.)
H
W
D
2
26-1/4
Weight Each
lb.
kg
Left-Hand Entry
CO22-U
CO22-200-U
CO22-200HI-U
CO23-U
Underground
only
CO23-200-U
CO23-200HI-U
CO24-U
CO24-200-U
CO24-200HI-U
2 gang with blank compartment, provision for Siemens 2 x (QJ),
200 A 2 pole 10 kA rated circuit breakers
2 gang with blank compartment, c/w Siemens 2 x QJ 200 A 2 pole 10 kA rated circuit breakers
2 gang with blank compartment, c/w Siemens 2 x QJH 200 A 2 pole 22 kA rated circuit breakers
3 gang with blank compartment, provision for Siemens 3 x (QJ),
200 A 2 pole 10 kA rated circuit breakers
3 gang with blank compartment, c/w Siemens 3 x QJ 200 A 2 pole 10 kA rated circuit breakers
3 gang with blank compartment, c/w Siemens 3 x QJH 200 A 2 pole 22 kA rated circuit breakers
4 gang with blank compartment, provision for Siemens 4 x (QJ),
200 A 2 pole 10 kA rated circuit breakers
4 gang with blank compartment, c/w Siemens 4 x QJ 200 A 2 pole 10 kA rated circuit breakers
4 gang with blank compartment, c/w Siemens 4 x QJH 200 A 2 pole 22 kA rated circuit breakers
3
4
30
35
43-3/4
5-1/2
60
27.21
80
36.29
100 45.36
Note: Ex. CO22-XXX, suffix (XXX) can be replaced by any of the following breaker amperage options: 100, 125 or 150. Consult your Regional Sales Office for price and availability.
w w w. t nb. c a
D35
Meter Sockets
CO42 Series
400 A (Main Lugs), 200 A per Position, Single Phase
120/240 V; Multiple Position Combination with
Compartment with or without Breaker
Product Specifications
5-1/2 in.
D
C
2-5/8 in.
H1 H2
4-3/8 in.
1-7/8 in.
2-5/8 in.
•Conductor range: Line: Dual rated connectors for 1 x 4 AWG-600 kcmil
or 2 x 1/0 AWG-250 kcmil, Load: 6 AWG-250 kcmil
•Aluminum tunnel type connectors for both load and line sides
•Combination overhead/underground
•Factory pre-bussed from main lugs to each position
• Supplied with hub opening closure plate for underground service
• Internal locking system for covers
•Larger hub opening requires use of 3 in., 3-1/2 in., or 4 in.
hubs unless BS052 adaptor plate is used
• Supplied with screw type rings
• Factory installed 2 pole circuit breaker, 10,000 A rms interrupting capacity
• Siemens Type “QJ” breaker
•With adjustable breaker plate for field installation of Square D and Eaton breakers
• Weatherproof Type 3R enclosure
•Primarily uses in: All Provinces
Quebec only: As per Hydro-Québec spec (supplied with 22 kA Siemens breaker)
Note: Consult your Regional Sales Office for right-hand entry option.
26-1/4 in.
1-5/8 in.
1-9/16 in.
1-5/8 in.
1-5/8 in.
2-1/2 in.
2-3/8 in.
4-3/8 in.
Hub
Cat. No.
34.594 in.
Trade Size
Knockout
1-1/4, 1-1/2, 2 and
2-1/2
1-1/4 in.
1-3/16 in.
37-21/32 in.
Trade Size
Knockout
1 Place
2, 2-1/2, 3, 3-1/2
Trade Size
Knockout
1 Place
1/2 in.
8-3/4 in.
8-3/4 in.
Hub Size C (in.) D (in.) H1(in.) H2 (in.)
MH10X
MH12X
MH15
MH20
MH25
MH30
MH35
MH40
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
1-7/16 N/A
1-5/8
N/A
1-11/16 N/A
1-15/16 N/A
2-1/8
N/A
N/A 2-7/16
N/A
2-7/8
N/A
2-7/8
1-1/8
1-1/32
1-1/32
1-1/32
1-7/16
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1-1/2
1-1/2
1-1/2
Approved for copper or aluminum
Cat. No.
Type
Left-Hand Entry
CO42
CO42-200
CO42-200HI
CO43
Combination
CO43-200
OH/UG
CO43-200HI
CO44
CO44-200
CO44-200HI
Description
2 gang with blank compartment, provision for Siemens 2 x (QJ), 200 A 2 pole 10 kA rated circuit breakers
2 gang with blank compartment, c/w Siemens 2 x QJ 200 A 2 pole 10 kA rated circuit breakers
2 gang with blank compartment, c/w Siemens 2 x QJH 200 A 2 pole 22 kA rated circuit breakers
3 gang with blank compartment, provision for Siemens 3 x (QJ), 200 A 2 pole 10 kA rated circuit breakers
3 gang with blank compartment, c/w Siemens 3 x QJ 200 A 2 pole 10 kA rated circuit breakers
3 gang with blank compartment, c/w Siemens 3 x QJH 200 A 2 pole 22 kA rated circuit breakers
4 gang with blank compartment, provision for Siemens 4 x (QJ), 200 A 2 pole 10 kA rated circuit breakers
4 gang with blank compartment, c/w Siemens 4 x QJ 200 A 2 pole 10 kA rated circuit breakers
4 gang with blank compartment, c/w Siemens 4 x QJH 200 A 2 pole 22 kA rated circuit breakers
Position
Dimensions (in.)
H
W
D
Weight Each
lb.
kg
2
26-1/4
75
39
3
37-1/2 39-3/8 5-1/2
100
36.29
4
43-1/2
125
56.70
Note: Ex. CO42-XXX, suffix (XXX) can be replaced by any of the following breaker amperage options: 100, 125 or 150. Consult your Regional Sales Office for price and availability.
D36
w w w.t nb.c a
Meter Sockets
CO27 Series
200 A, 120/208
/208 V; Combination Polyphase with Breaker
Product Specifications
•
•
•
•
•
•
•
•
•
•
Conductor range (Line and Load): 2 AWG-250 kcmil
Aluminum tunnel type connectors
Suitable for 120/208 V polyphase service entrance
For overhead installation
Larger hub opening requires use of 3 in., 3-1⁄2 in. or 4 in. hubs unless BS052
adaptor plate is used
Factory installed 3 pole circuit breaker, 10,000 A rms interrupting capacity
“QJ” Type Siemens 10 kA breaker
Weatherproof Type 3R enclosure
Supplied with screw type rings
Primarily uses in: All Provinces
Quebec only: As per Hydro-Québec spec (supplied with 22 kA Siemens breaker)
A
5-1/2 in.
6-1/8 in.
2-1/2 in.
12 in.
Trade Size
Knockout
1/4 in.
Trade Size
Knockout
1/2 in.
1-9/16 in.
9-13/16 in.
2-1/4 in.
4-3/4 in.
47/64 in.
1-1/2 in.
1-31/64 in.
3-11/16 in.
Hub
Cat. No.
MH30
MH35
MH40
Hub
Size
3
3-1/2
4
32-13/16 in.
A (in.)
2-5/16
2-3/4
2-3/4
1, 1-1/4, 1-1/2, 2, 2-1/2, 3 in.
3 Sets
1-9/16 in. 2-1/4 in.
Approved for copper or aluminum
Cat. No.
Type
Left-Hand Entry c/w Breaker
CO27B-100
Overhead
CO27B-150
CO27B-200
w w w. t n b. c a
Description
c/w Siemens QJ 100 A 3 pole 10 kA rated circuit breaker
c/w Siemens QJ 150 A 3 pole 10 kA rated circuit breaker
c/w Siemens QJ 200 A 3 pole 10 kA rated circuit breaker
H
Dimensions (in.)
W
D
32-3/4
11-13/16 5 -7/16
Weight Each
lb.
kg
30
13.6
D37
Meter Sockets
BP320 Series
320 A 600 V Self Contained Meter Socket
Product Specifications Overhead
Product Specifications Underground
•320 A overhead 600 V maximum
•Self-contained meter socket with bypass
mechanism
•Single phase service
•Line and load side termination; tunnel type
connectors; Dual rated for 1 x 500 kcmil or
2 x 250 kcmil
•Neutral termination; tunnel type connectors;
Dual rated 2 x 250 kcmil
•Supplied with screw type sealing ring
• Weatherproof type 3R enclosure
•Primarily uses in: All Provinces
•320 A underground 600 V maximum
•Self-contained meter socket with bypass
mechanism
•Single phase service
•Neutral and line side terminations; double
1/2 in. studs to accomodate compression lugs
for underground service (1 x 500 kcmil or
2 x 250 kcmil)
• Load side terminations; tunnel type connectors;
Dual rated for 1 x 500 kcmil or 2 x 250 kcmil
•Neutral load side terminations; tunnel type
connectors; Dual rated 2 x 250 kcmil
•Supplied with screw type sealing ring
• Weatherproof type 3R enclosure
•Primarily uses in: All Provinces
CAT. NO.: BP250
(BP320-V)
OVERHEAD
UNDERGROUND
Approved for copper or aluminum
Cat. No.
BP320-V
BP320-V-08
BP320-V-09
BP320-V-11
BP320-TV
BP320-TV-08
BP320-TV-09
BP320-TV-11
Accessory
BP250
D38
Type
OH
UG
Description
Overhead 320 A 120/240 with bypass mechanism
Underground 320 A 120/240 with bypass mechanism
Color
Position
Grey
Dark Grey
White
Beige
Grey
Dark Grey
White
Beige
1
H
Dimensions (in.)
W
D
34-1/16
15-9/16
5-15/16
Weight Each
lb.
kg
47
21.31
Connector kit 2 x 250 kcmil
w w w.t nb.c a
Meter Sockets
FA4B-6T
400 A 600 V; “All In One” Transformer Rated
Product Specifications
•
•
•
•
•
•
•
•
•
Max. single conductor 600 kcmil Cu or Dual parallel conductors 250 kcmil Cu/Al
Load and line side termination at discretion of utility
For underground service only
Meter socket configuration for 6 jaws
Complete with 6 pole test switch
Complete with 2 fuseholders and 3 A 32 V fuses
Installation of current transformer at discretion of utility
Two 1, 1-1/4, 1-1/2, 2, 2-1/2 and 3 in. bottom K.O.’s
Permanent red nameplate affixed to front cover warns that removal of meter
does not isolate the load terminals; also warning to short circuit current
transformer (secondary) before removal of meter
• Weatherproof Type 3R enclosure
• Primarily used in: Alberta
13-5/16 in.
Note: Photo is of an installed meter socket; current transformers are not included.
2-1/2 in.
5 in.
8-3/4 in.
5-5/16 in.
8-1/2 in.
Trade Size
Knockout
1, 1-1/4,
1-1/2, 2, 2-1/2,
3 and 4 in.
4 Places
(FA4B-6T)
40-5/8 in.
RED
WHT
YEL
WHT
RED
BLK
RED
BLK
YEL
BLK
43-3/4 in.
19-1/8 in.
F1
3A
F2
3A
GRN
6-1/6 in.
1-9/16 in.
Knockout
1, 1-1/4, 0.21 in.
1-1/2, 2,
2-1/2 and 3
Knockout
1/2 in.
3-1/2 in.
3-1/2 in.
6-9/16 in.
Load
Knockout
13/32 in.
7-1/16 in.
6-7/8 in.
3-1/8 in.
1-1/16 in.
1-1/16 in.
Line
8-7/16 in.
6 in.
3-1/2 in.
Approved for copper or aluminum
Cat. No.
FA4B-6T
w w w. t n b. c a
Description
Underground c/w 6 pole test switch
Dimensions (in.)
H
D
13-5/16
8-7/16
Weight Each
lb.
kg
50
22.67
D39
Meter Sockets
JS4 Series
400 A 120/240 V; Single Phase Service
Product Specifications
•Load side terminations: tunnel type connectors, dual rated for 1 x 500 kcmil
or 2 x 250 kcmil
•Fully wired secondary circuits
•Line side terminations: double 1/2 in. studs to accommodate compression lugs
(supplied by utility) for underground service (1 x 500 kcmil or 2 x 250 kcmil)
•Permanent red nameplate affixed to front cover warns that removal of meter
does not isolate the load terminals; also notice of automatic circuit closing
device on JS4A and warning to short circuit current transformer secondary
before removal of meter on JS4B
•Meter socket configuration for 5 jaw meters (can be readily converted to
suit meter forms requiring 4 blades)
•400/5 A three-wire current transformer provides low current for service
metering proportional to higher current draw. Consumer and Corporate Affairs
Canada approved for revenue metering (200/5 and 300/5 A also available)
•Gutter wiring space provided on left side
•Twin covers allow access to either compartment (single cover available on request)
•Hub opening closure plate for underground service. All units can be
converted to overhead service with addition of conduit hub and JS250
or JS500 tunnel type connector kit
•Hinged bridges and readily removable crossbar with keyholes permit easy
wiring without obstructions
•Heavy gauge galvanized steel. Ovencured grey enamel finish.
•For aluminum JS4’s see page D41 for product specs and dimensions
•Three 1-1/4 in., 1-1/2 in., 2 in., 2-1/2 in., 3 in., 3-1/2 in., 4 in. Bottom Knockouts
•Weatherproof Type 3R enclosure
(JS4B)
(JS4A)
KIT-400MH
(see page D58)
Trade Size
Knockout
1, 1-1/4, 1-1/2, 2,
2-1/2, 3, 3-1/2 and 4 in.
3 Places
Trade Size
Knockout
1/2 in.
2 Places
Additional 2-1/2 in.
opening for parallel run
3-1/8 in.
3-1/8 in.
3-13/16 in.
1-1/8 in.
10-1/8 in.
5-3/4 in.
2-1/2 in.
2-1/2 in.
4 in.
1 in.
1-1/8 in.
10-1/8 in.
20-1/4 in.
3-13/16 in.
Approved for copper or aluminum
Product Usage by Province/Utility
Newfoundland
JS4B-4ST, JS4B-NL,
JS4B-EALNL
Saskatchewan
JS4A-4TWE
Northern Ontario
JS4A, JS4A-4
Quebec
None approved
Alberta
JS4B-4T
Cornwall Hydro
JS4A-4T
Nova Scotia
JS4B-STNS
British Colombia
JS4B-STWINL
Ottawa Hydro
JS4AB-TW
Toronto Hydro
JS4AB-300/5
New Brunswick
JS4B (EAL)
Hydro Ontario
JS4A, JS4A-200/5, JS4A-300/5, JS4A-4,
JS4A-4T, JS4B, JS4B-4 JS4B-ST, JS4AB
Manitoba
JS4A-4TW, JS4A-4TWEAL
Hydro One
JS4B-TWLHO
D40
w w w.t nb.c a
Meter Sockets
JS4 Series
400 A 120/240 V; Single Phase Service
Approved for copper or aluminum
Cat. No.
JS4 Underground 400 to 5 Ratio • 5 Jaw • Twin Cover
JS4A
JS4B
Equipped with automatic circuit closing device
Equipped with test switches
1 x 500 kcmil
2 x 250 kcmil
UNDERGROUND SERVICE
Include
Factory Modifications
-4
-S
-T
-W
-Z
-200 / 5
-300 / 5
4 jaw meter socket configuration
Provision only for test switches (test switches supplied by power authority)
Provision only for current transformer (transformer supplied by power authority)
Secondary circuit wiring not included (secondary circuit wired by power authority)
”Peerless security” collar (S102WD)
200 A to 5 ratio current transformer
300 A to 5 ratio current transformer
2 x 250 kcmil
with kit no. JS250
1 x 500 kcmil
with kit no. JS500
Cat. No.
Overhead Entry Conversion Kits (1 Kit Required per Socket)
JS250
JS500
KIT-JS4B
2 x 250 kcmil tunnel connector kit for line side terminations
OVERHEAD SERVICE
1 x 500 kcmil tunnel connector kit for line side terminations
5th jaw assembly kit for NB Power
Note: Refer to page D40 for “Product usage by Province utility”
JS4 Series – Single Phase Service Aluminum only
Product Specifications
• Line side terminals: Overhead: 1 x 750 kcmil Cu
Al or 2 x 350 kcmil Cu Al Underground: 2 x 1/2 in.
stud to accommodate, 1 x 750 kcmil or 2 x 350
kcmil Cu Al compression lugs
• Load side terminals: 1 x 750 kcmil Cu or Al
or 2 x 350 MCM Cu/Al
• Combination overhead/underground meter socket
• 4 jaws meter socket configuration
JS4B-EAL
(New Brunswick)
Overhead Kit required (1 kit per socket)
JS350 2 x 350 kcmil Overhead Kit
JS750 1 x 750 kcmil Overhead Kit
JS4B-4STNSEAL
(Nova Scotia)
JS4A-4TWEAL
(Manitoba)
Trade Size Knockout
1, 1-1/4, 1-1/2, 2, 2-1/2, 3, 3-1/2 and 4 in.
3 Places
Trade Size Knockout
1/2 in.
2 Places
3-1/4 in.
1-1/8 in.
1-1/16 in.
1-1/8 in.
1-1/16 in.
3-3/4 in.
Cat. No.
Description
JS4A-4TWEAL
JS4B-EAL
JS4B-4STNSEAL
Aluminum Feed 400 A meter socket (Manitoba only)
Aluminum Feed 400 A meter socket (New Brunswick only)
Aluminum Feed 400 A meter socket (Nova Scotia only)
w w w. t n b. c a
6-5/16 in.
6-5/16 in.
Approved for copper or aluminium
H
Dimensions (in.)
W
D
38-1/8
20-1/16
8-1/4
Weight Each
lb.
kg
31.75
70
72
32.65
D41
Meter Sockets
Typical Wiring Diagrams
Reference Meter
Sockets
4 Jaw
110/220 V 1Ø3 W
BA3-
Reference
Meter Sockets
7 Jaw
3 PH 4W
PL17
GR.
BE1110
BQ2-
PL27
A
B
N
GR.
C
110
220
BS2MO2-
L2
L1
A
N
CO2-
C
B
N
LOAD
Reference Meter
Sockets
BE1-5
5 Jaw
3 PH 4W
GR.
N
BS2-5
120
BE1-6
5 Jaw
3 PH 3W
BE1-5-INV
A
BQ2-5
BS2-6
Reference Meter
Sockets
C
208
L1
BS2-5-IN
A
B
C
120
N
5TH
L2
C
A
B
5TH
NETWORK
D42
w w w. t n b. c a
Meter Sockets
Typical Wiring Diagrams
Reference Meter
Sockets
4 Jaw 1PH
CMS
Reference
Meter Sockets
CT104
CL4-V
8 Jaw
3 PH 3W
CT108
CT
CT
A
L1
B
N
C
L2
CT
I E
I
Reference Meter
Sockets
E I
E
13 Jaw
3 PH 3W
CT113
CT
CT
A
N
B
GR.
C
w w w. t n b. c a
D43
Meter Sockets
Accessories
Stainless Steel Sealing Rings
Cat. No.
MSR-C2
Description
Stainless steel sealing ring, tamper-proof
MSR-C2
Polycarbonate Sealing Ring
Cat. No.
S102WD
Description
Ring, available with any meter socket
When ordering any meter socket, add suffix “Z” to meter socket cat. no. to exchange standard stainless steel ring for S102WD model.
S102WD
Meter Protectors
Product Specifications
• Meter protector for use in problem areas (trailer parks, playgrounds, conservation areas)
• Steel construction (16 ga. galv. steel)
• Clear, unbreakable polycarbonate front cover, which allows full view of meter revenue
reading and serial number
• Sealing and padlocking provision
• Grey painted
Cat. No.
MP01 / MP02
D44
MP01
MP02
Description
7-1/6 in. dia. x 4-3/4 in. deep for use with single phase residential meters
7-1/6 in. dia. x 8-3/4 in. deep for use with all meters, other than single phase residential meters
w w w. t n b. c a
Meter Sockets
Accessories
Blank Meter Cover Plates
Description
Cat. No.
BS087
BS089
BS090
Grey ABS
Plastic “throw-away” cover
Clear unbreakable polycarbonate
BS087 / BS089 / BS090
Jumper Bar
Description
Cat. No.
CM-BS100
CM-BS100
200 A Max.
Meter Jaw Safety Shroud
Description
Cat. No.
LS500
Red polycarbonate, 100/200 A
Mast Coupler
LS500
Description
Cat. No.
MH200
Fits all sockets with regular 2-1/2 in. hub opening
Mast Hubs
MH200
B
A
MH10X
B
Cat. No.
PVC Cat. No.
MH10X
MH12X
MH15
MH20
MH25
MH30
MH35
MH40
—
E991G
E991H
E991J
E991K
—
—
—
A Hub Size (in.)
B
1
1-1/4
For 2-1/2 in. regular hub opening
(add hub adapter plate BS052 if used
with units having 4 in. hub openings)
1-1/2
2
2-1/2
3
3-1/2
For 4 in. hub opening
4
Supplied with 4 Robertson head screws.
Hub Adapter Plate
Cat. No.
BS052
w w w. t nb. c a
BS052
Description
Permits use of regular size hubs on larger hub openings
D45
Meter Sockets
Accessories
Hub Opening Closure Plates
Cat. No.
Description
BS051
BS054
Inside attachment for regular hub opening (i.e.: 1 in. to 2-1/2 in.)
Inside attachment for larger hub opening (i.e.: 3 in. to 4 in.)
Insulated Neutral Kits
Cat. No.
Description
IN1000BA, IN1000BE, IN1000PL
IN2000BS, IN2000PL
100 A Max.
200 A Max.
Specify socket upon ordering.
Insulated Neutral Kit
Cat. No.
Description
IN4000JS
400 A Max. (JS4)
Ground Lug On Neutral Kit
Cat. No.
Description
GN2000
200 A Max. for BQ2, BS2 Series
Micro-ID-Kit
Cat. No.
MINI-ID-KIT
MICRO-ID-KIT
Description
Markers Kit Includes
Plastic case
Qty.
Stainless steel markers of each numbers 0 thru 9 (dash + service)
Stainless steel markers of each letters A thru D
Stainless steel markers of each numbers 0 thru 9
Blue metal
Words “SERVICE”
carrying case
CM-BS100 Jumper Bar 200 A Max.
LS500 Meter Jaw Safety Shroud
10
10
4
10
Supplied with 4 Robertson head screws.
Identification Markers
Cat. No.
No. 0 through No. 9
No. A through No. Z
No. SERVICE
Description
Clipped to the upper lip of the enclosure; provides permanent customer identification.
Packed and sold in polyethylene bags of 10 identical markers except “SERVICE” which
has 7 individual letters
Replacement + Block Assemblies
Consist of thermoplastic insulators
with jaws and connectors assembled
for replacement of one meter socket
Cat. No.
Description
BA3-X
BS2-X-UNI
MO2-X-UNI
PL27-XEB
Fits BA3 / BE1 Series
Fits BQ2 / BS2 Series uni block
Fits MO2 Series uni block
Fits PL27 Series uni block
Add suffix “B” to cat. no. above if mounting bridge is required
D46
w w w. t n b. c a
Meter Sockets
Accessories
Fifth Jaw Assemblies
Standardcapacity
9 o’ position
C205
•
•
•
•
•
•
•
•
•
•
•
•
Meter Socket
Series
BA3
BDC
BE1
BE2
BEC
BD2
BQ2
BS2 / BS2L
BS4 / BSC4
CO1
CO2
CO1 Multigang
Full capacity
9 o’ position
Z105*
Z205*
•
•
•
•
•
•
•
•
•
•
•
•
Full capacity
6 o’ position
CM-B106*
B306*†
•
•
•
•
•
•
Fifth Jaw Assemblies
•
•
•
* CSA not applicable † For mono blocks only
Pole Mount Bracket Kit
Cat. No.
Description
PMB200
Secures
Microlectric meter
socket to a
wooden pole via
Option 1 or 2
Conductor
Range
14-2 AWG
Use w/Series
Option 1
Option 2
Use the two side
BA3, BE1, BQ2,
bracket mounting
BS, CL, CO1, CO2, Use a lag bolt through
holes (0.320 in. dia.)
CT, MO2, PL17, 5/8 in. center keyhole
to wrap around
PL27, VT
the pole
Pole Mount Bracket Kit
Suitable for any Microlectric meter socket with mounting holes 5 in. apart. Attach meter socket using one or two bracket(s).
PMB200 kit comes complete with 2 brackets, 1 ground connector. Includes assembly hardware.
Pole Mounting Kit
Cat. No.
PMBJS4
Kit Includes
Support hangers
1/2 in. x 4 in. lag bolt
3/8 in. x 3 in. lag bolt
5/16 in. x 1 in. carriage bolts, nuts and lock washers
Qty.
2
1
4
Pole Mounting Kit
Pole Line Hardware
Cat. No.
Description
RC729
BC301L
BO506
BO508
BO510
BO512
Square washer
Carriage bolt
F Dia.
(in.)
5/8
3/8
Oval eye bolt
5/8
G Dia.
(in.)
2
1-1/2
6
8
10
12
H Dia.
(in.)
–
1-1/2
3
4
4
4
F
G
T Thick
(in.)
3/16
–
Weight (100 pcs)
lb.
kg
22
10.0
11
5.0
122
55.4
136
61.8
150
68.1
168
76.3
Std. Pkg.
400
50
F
F
H
H
G
G
G
T
RC729
w w w. t n b. c a
BC301L
BO Series
D47
Meter Sockets
Accessories
Breaker Mounting Bracket
Description
Cat. No.
Adjustable Mounting Bracket for CO2 Series to adapt to Siemens,
SD and Cutler Hammer breakers
CO3417M-1-FG
Meter Adaptor Bracket
Flexible Braid Kit
Description
Cat. No.
CO2FB-KIT
Connection wires adaptor kit for CO2 Series meter sockets for field installation.
To be used with Cutler Hammer breakers
Connector Kit
Description
Cat. No.
Flexible Braid Kit
BP250
Connector kit 2 x 250 kcmil
Service Entrance Heads
Cat. No.
Trade Size
Service Entrance Heads
(Cast Aluminum) Rigid Conduit
Connector Kit
CIEFA-1/2
CIEFA-3/4
CIEFA-1
CIEFA-1 1/4
CIEFA-1 1/2
CIEFA-2
CIEFA-2 1/2
CIEFA-3
CIEFA-3 1/2
CIEFA-4
1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
Trade
Size
1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
0.610
0.750
0.875
KO Dimensions
Large
–
0.400
0.500
0.625
0.750
1.000
1.300
1.125
1.750
Small
0.312
0.375
0.438
Center
–
0.400
0.525
1.000
1.125
Service Entrance Heads
(Cast Aluminum) E.M.T.
CIEFA-1/2 / CIEFA-4
CIEFSA-1/2 / CIEFSA-4
KO Configuration
D48
1/2 in.
3/4 in. - 1-1/4 in.
1-1/2 in., 2 in.
2 -1/2 in., 4 in.
CIEFSA-1/2
CIEFSA-3/4
CIEFSA-1
CIEFSA-1 1/4
CIEFSA-1 1/2
CIEFSA-2
CIEFSA-2 1/2
CIEFSA-3
CIEFSA-3 1/2
CIEFSA-4
1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
w w w.t nb.c a
Meter Sockets
Meter Covers
Meter Series
AB
BA
BE1
BE2V
BE3V
BE4V
BE5V
BE6V
BEC2V
BEC3V
BEC4V
BEC5V
BEC6V
BP2-TV
BQ2V
BS2V
BS2L
BS4M-V
MO2V
PL17
PL27
BS42
BS43
BS44
BS45
BS46
BSC42V
BSC43V
BSC44V
BSC45V
BSC46V
BD2V
BD3V
BD4V
BDC2
BDC3
BDC4
w w w. t n b. c a
With
Meter Hole
1 X AB1021A FG
1 X BS3321 FG
1 X BS1321 FG
2 X BS1321 FG
3 X BS1321 FG
4 X BS1321 FG
5 X BS1321 FG
6 X BS1321 FG
2 X BS4321 FG
3 X BS4321 FG
4 X BS4321 FG
5 X BS4321 FG
6 X BS4321 FG
1 X PL7321 FG
1 X BS2321 FG
1 X BSC2321 FG
1 X BS8321 FG
1 X BS2321 FG
1 X PL7321 FG
2 X BS5521-FG
3 X BS5521-FG
4 X BS5521-FG
5 X BS5521-FG
6 X BS5521-FG
2 X BS5521-FG
3 X BS5521-FG
4 X BS5521-FG
5 X BS5521-FG
6 X BS5521-FG
2 X BD5421 FG
3 X BD5421 FG
4 X BD5421 FG
2 X BD5421 FG
3 X BD5421 FG
4 X BD5421 FG
Without
Meter Hole
Meter Series
CO1
CO2
CO2M
Top Cover “Meter”
CO2321 FG
CO3322 FG
CO3322 MFG
Bottom Cover “Breaker”
CO2023 FG
CO3021 FG
–
Meter Series
CO2MS
1 X BS4321A FG
–
1 X BS5521A-FG
Top
CO3322 MFG
Middle
CO3321 MSFG
Bottom
CO3323 MSFG
Meter Series
CT104-5SWLHQ
CT-L
CT-SWL
CT
CL
HD
JS4
JS4 (EAL)
Top Cover “Meter”
CT2321FG
CT1321FG
CT1321FG
CT1321 FG
BS3321 FG
HD102/A
JS5321A FG
JS5321A FG
Bottom Cover
CT2023FG
CT1023FG
CT1023FG
CT1021AFG
–
HD1022A
JS5221B FG
JS5221B EAL
Meter Series
CO22
CO42
Top Cover “Meter”
CO5322FG
CO8342FG
Bottom Cover
CO8021FG
C08021FG
2 X BS5521A-FG
1 X BD5421A FG
1 x BDA5521A FG
D49
Meter Sockets
Service Masts
Service Entrance Masts and Accessories
1
2
16
3
4
17
5
8
1 in.
6
7
/ 2 in
22-1
18
4-7
/8 i
9
10
3/4
c
in.
rw
en t e
a
. ho
ll mt
.
n.
les
5 in
.
11
19
10 in.
5 in.
12
2 in
11-1/
1-3/8 in.
13
20
VARIOUS SERVICE ENTRANCE MAST KITS
ARE AVAILABLE; PLEASE INQUIRE
AT YOUR NEAREST
THOMAS & BETTS SALES OFFICE.
14
15
21
22
23
Fittings for old style 2-3/4 in. outside diameter service masts.
D50
w w w. t n b. c a
Meter Sockets
Service Masts
Service Entrance Masts and Accessories
Reference No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
w w w. t nb. c a
Cat. No.
MM104
MM105
MM202
MM380
MM380A
MM101
MM5101
MM201
MM801
MM390
MM300
MM500
MM501
MM502
MM503
MM505N
MM5505N
MM250
MM251
MM255
MM252
MM400
MM401
MM445
MM5400
MM8
MM9CM
MM10
MM12
MM600
MM601
MM602
MM602LD
MM603
MM100
MM140
MM140M
MM150
MM150M
MM200
MM200M
MH200
MH40
MM506N
MM806N
MM507DN
MM604
MM605
MM700
MM202P
CIEFA-4
MM200P
MC250
lb./kg 100 pcs
105/47.1
130/59
200/90
Std. Pkg.
20
50/22.7
50
125/56
164/74
300/136
360/163
50/22.7
100/45.4
14/6.3
36/16.3
150/68
180/81
140/63
140/63
125/56
40/18.1
40/18.1
30/13.6
225/102
110/50
10
20
10
10
50
20
50
10
20
50
20
215/97
2800/1272
3300/1500
3500/1590
4200/1909
235/106
190/86
150/68
119/54
200/90
36/16.3
44/20
40/18
103/46.82
52/23.6
100/45
93/42.3
150/68
50/22.7
85/38.6
200/90
590/268
44/20
45/21
50
20
25
1
10
10
25
50
10
1
20
30
Description
1-1/4 in. Entrance cap 100 A
1-1/2 in. Entrance cap 150–200 A
2 in. Entrance cap 200 A
Guy attachement c/w oval eye
Guy attachement without oval eye complete with bracket
Light duty spool rack 100 A
Light duty spool rack (Alberta only) 100 A
Heavy duty spool rack 200 A
Heavy duty spool rack 400 A, fits 3 in. and 4 in. Rigid conduit
Drop wire hook bracket
Service mast wire holder
Neoprene collar only
Steel collar only
Roof base flange only
Roof flange C/W steel collar
Roof flange C/W neoprene collar
Roof flange C/W neoprene collar 1-1/4 in.
1/2 in. dia. «U» bolt mast clamp
Pipe strap C/W two 3/8 in. x 4 in. lag screws
Pipe strap C/W two 3/8 in. x 5 in. lag screws
Pipe strap only less lag screws
Support clamp C/W 5/8 in. x 10 in. fully threaded bolt and 4 in. x 4 in. square washer
Clamp only less bolt and washer
Support clamp C/W 5/8 in. x 4-1/2 in. fully threaded bolt and 4 in. x 4 in. square washer
Support clamp C/W 1/2 in. x 10 in. bolt
8 ft. x 2-1/2 in. outside diameter mast
9 ft. x 2-1/2 in. outside diameter mast
10 ft. x 2-1/2 in. outside diameter mast
12 ft. x 2-1/2 in. outside diameter mast
Meter spacer complete with pipe strap; 5/8 in. x 4-1/2 in. carriage bolt and 4 in. x 4 in. square washer
Same as above except no pipe strap
Spacer only (less strap, bolt and washer) (suggested for brick applications with MM201 less pipe strap)
Light duty spacer only (less strap, bolt and washer)
Spacer with pipe strap (less bolt and washer)
1 in. Female reducer
1-1/4 in. Female reducer
1-1/4 in. Male reducer
1-1/2 in. Female reducer
1-1/2 in. Male reducer
2 in. Female reducer
2 in. Male reducer
2 in. Mast adaptor
4 in. Mast coupler
Simple all neoprene roof flange, 200 A, for 2-1/2 in. masts
Simple all neoprene roof flange, 400 A, for 4 in. masts
Double all neoprene roof flange; for 2-1/2 in. masts
Meter socket bracket (Dimensions see page D50)
Meter socket mounting bracket (Dimensions see page D50)
Service mast ground clamp, wire range: 8-1/0 AWG
2 in. entrance cap for old style 2-3/4 in. service masts
4 in. entrance head
2 in. female reducer for old style 2-3/4 in. service masts
2-1/2 in. one-piece coupler (check the installation standards in your region before using the product)
D51
Meter Sockets
Service Masts
Guy Kits for 2-1/2 in. Masts
MM914
MM9516
Cat. No.
Qty.
Consists of
Description
MM380
GT516
GE14
GW14110
GC902
RB404
T404-CM
Mast Guy Attachment
Guy Thimbles
Guy End
20 ft. of 1/4 in. Guy Wire
Guy Clamp
Roof Bracket
Lag Screw
MM380
GT516
GE516
GW516110
GC902
BTE512
RA725
Mast Guy Attachment
Guy Thimble
Guy End
20 ft. of 5/16 in. Guy Wire
Guy Clamp
5/8 in. x 12 in. Bent Thimble Eye Bolt
Round Washer
1/4 in. Guy Kit
1
2
MM914
1
5/16 in. Guy Kit
MM9516
D52
1
w w w. t n b. c a
Meter Sockets
Service Masts
Mast Kits Suitable for British Columbia
Cat. No.
Qty.
1
KIT-100BCMH
3
1
KIT-100BCMN
3
1
MMK1-NMH
3
1
KIT-200BCMH
3
1
MMK2-NMH
3
1
w w w. t n b. c a
Consists of
MM104
MM101
MM505N
MM250
MH200
MM104
MM101
MM505N
MM250
MM140
MM104
MM101
MM505N
MM400
MH200
MM202
MM201
MM505N
MM250
MH200
MM202
MM201
MM505N
MM400
MH200
Description
Entrance Cap
Light Duty Rack
Flange c/w Neoprene Collar
“U” Bolt Clamp
Mast Coupler
Entrance Cap
Light Duty Rack
Flange c/w Neoprene Collar
“U” Bolt Clamp
1-1/4 in. Female Reducer
Entrance Cap
Light Duty Rack
Flange c/w Neoprene Collar
Support Clamp
Mast Coupler
Entrance Cap
Heavy Duty Rack
Flange c/w Neoprene Collar
“U” Bolt Clamp
Mast Coupler
Entrance Cap
Heavy Duty Rack
Flange c/w Neoprene Collar
Support Clamp
Mast Coupler
D53
Meter Sockets
Service Masts
Mast Kits Suitable for Alberta
KIT-1 1/4 – 100 A
Cat. No.
Qty.
Consists of
Description
This mast kit is used in conjunction with 1-1/4 in. rigid conduit
KIT-1 1/4
KIT-1 1/4
1
MM5104A
MM5101
MM5505N
MM5400
1-1/4 in. Throat Entrance Cap
Light Duty Spool Rack
Roof Flange c/w Neoprene Collar
Support Clamp c/w 1/2 in. x 10 in. Bolt
Consists of
Description
KIT2-CM – 100 A
Cat. No.
Qty.
This mast kit is used in conjunction with 2 in. rigid conduit
1
KIT2-CM
2
1
MM5104B
MM5101
MM505N
MM5400
MM5140
2 in. Throat Entrance Cap
Light Duty Spool Rack
Roof Flange c/w Neoprene Collar
Support Clamp c/w 1/2 in. x 10 in. Bolt
1-1/4 in. Bottom Female Reducer
Consists of
MM202
MM5101
MM505N
MM5400
MM200M
Description
Entrance Cap
Light Duty Spool Rack
Roof Flange c/w Neoprene Collar
Support Clamp c/w 1/2 in. x 10 in. Bolt
2 in. Reducer
Consists of
MM104
MM201
MM505N
Description
1-1/4 in. Entrance Cap
Heavy Duty Spool Rack
Roof Flange c/w Neoprene Collar
Support Clamp c/w 5/8 in. x 10 in.
Fully Threaded Bolt and 4 x 4 Washer
1-1/4 in. Female Reducer
KIT-2-AL – 200 A
KIT2-CM
Cat. No.
Qty.
1
KIT-2-AL
2
1
MB-110 – 100 A
Cat. No.
Qty.
KIT-2-AL
1
MB-110
3
MM400
1
MM140
MB-110
D54
w w w. t n b. c a
Meter Sockets
Service Masts
Mast Kits Suitable for Manitoba and Saskatchewan
Cat. No.
Qty.
1
KIT-100MJ
2
1
KIT-100MN
1
3
1
KIT-100MH
3
1
KIT-200AM
1
3
1
KIT-200MH
3
1
KIT-200MJ
KIT-200MNF
1
1
3
1
MMK2-NMH
3
1
w w w. t n b. c a
Consists of
MM104
MM140M
MM101
MM505N
MM251
MM400
MM104
MM140M
MM101
MM505N
MM255
MM104
MM101
MM505N
MM251
MH200
MM202
MM201
MM200M
MM505N
MM255
MM202
MM201
MM505N
MM255
MH200
MM202
MM200M
MM201
MM505N
MM251
MM400
MM202
MM201
MM200M
MM251
MM202
MM201
MM505N
MM400
MH200
Description
Entrance Cap
1-1/4 in. Reducer
Light Duty Rack
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 4 in. Lag Bolt
Support Clamp
Entrance Cap
1-1/4 in. Reducer
Light Duty Rack
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 5 in. Lag Bolt
Entrance Cap
Light Duty Rack
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 4 in. Lag Bolt
Mast Coupler
Entrance Cap
Heavy Duty Rack
2 in. Male Reducer
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 5 in. Lag Bolt
Entrance Cap
Heavy Duty Rack
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 5 in. Lag Bolt
Mast Coupler
Entrance Cap
2 in. Male Reducer
Heavy Duty Rack
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 4 in. Lag Bolt
Support Clamp
Entrance Cap
Heavy Duty Rack
2 in. Male Reducer
Strap c/w 3/8 in. x 4 in. Lag Bolt
Entrance Cap
Heavy Duty Rack
Flange c/w Neoprene Collar
Support Clamp
Mast Coupler
D55
Meter Sockets
Service Masts
Mast Kits Suitable for Ontario
Cat. No.
KIT-100HDM
Qty.
1
3
1
KIT-100MH
3
1
KIT-100MN
1
3
KIT-100NMH
MMK1
1
1
3
1
MMK-1N
3
1
1
MMK1-NMH
3
1
KIT-200MH
1
3
1
KIT-200AM
3
1
D56
Consists of
MM104
MM140M
MM201
MM503
MM255
MM104
MM101
MM505N
MM251
MM200
MM104
MM140M
MM101
MM505N
MM255
MM104
MM101
MM505N
MM400
MM200
MM104
MM101
MM140M
MM503
MM400
MM104
MM101
MM505N
MM400
MM140M
MM104
MM101
MM505N
MM400
MH200
MM202
MM201
MM200M
MM505N
MM255
MM202
MM201
MM505N
MM255
MH200
Description
Entrance Cap
1-1/4 in. Male Reducer
Heavy Duty Rack
Flange c/w Steel Collar
Strap c/w 3/8 in. x 5 in. Lag Bolts
Entrance Cap
Light Duty Rack
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 4 in. Lag Bolt
Female Reducer
Entrance Cap
1-1/4 in. Male Reducer
Light Duty Rack
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 5 in. Lag Bolt
Entrance Cap
Light Duty Rack
Flange c/w Neoprene Collar
Support Clamp
Female Reducer
Entrance Cap
Light Duty Rack
1-1/4 in. Male Reducer
Flange c/w Steel Collar
Support Clamp
Entrance Cap
Light Duty Rack
Flange c/w Neoprene Collar
Support Clamp
1-1/4 in. Male Reducer
Entrance Cap
Light Duty Rack
Flange c/w Neoprene Collar
Support Clamp
Mast Coupler
Entrance Cap
Heavy Duty Rack
2 in. Male Reducer
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 5 in. Lag Bolt
Entrance Cap
Heavy Duty Rack
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 5 in. Lag Bolt
Mast Coupler
Cat. No.
Qty.
1
KIT-200NMH
3
1
MMK2
1
3
1
MMK-2N
3
1
1
MMK2-NMH
3
1
Consists of
MM202
MM201
MM505N
MM400
MM200
MM202
MM201
MM200M
MM503
MM400
MM202
MM201
MM505N
MM400
MM200M
MM202
MM201
MM505N
MM400
MH200
Description
Entrance Cap
Heavy Duty Rack
Flange c/w Neoprene Collar
Support Clamp
Female Reducer
Entrance Cap
Heavy Duty Rack
2 in. Male Reducer
Flange c/w Steel Collar
Support Clamp
Entrance Cap
Heavy Duty Rack
Flange c/w Neoprene Collar
Support Clamp
2 in. Male Reducer
Entrance Cap
Heavy Duty Rack
Flange c/w Neoprene Collar
Support Clamp
Mast Coupler
w w w. t n b. c a
Meter Sockets
Service Masts
Mast Kits Suitable for Quebec
Cat. No.
KIT-100MN
Qty.
1
3
1
KIT-100MH
3
1
KIT-100MNF
1
3
1
KIT-150AM
3
1
KIT-200AM
1
3
1
KIT-200AMGR
3
1
1
KIT-200MH
3
1
KIT-200MNF
3
w w w. t n b. c a
Consists of
MM104
MM140M
MM101
MM505N
MM255
MM104
MM101
MM505N
MM251
MH200
Description
Entrance Cap
1-1/4 in. Male Reducer
Light Duty Rack
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 5 in. Lag Bolts
Entrance Cap
Light Duty Rack
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 4 in. Lag Bolts
Mast Coupler
MM104
Entrance Cap
MM140M
MM101
MM251
MM105
MM201
MM505N
MM251
MM150M
MM202
MM201
MM200M
MM505N
MM255
MM202
MM201
MM200M
MM505N
MM255
MM700
MM202
MM201
MM505N
MM255
MH200
MM202
MM201
MM200M
MM251
1-1/4 in. Male Reducer
Light Duty Rack
Strap c/w 3/8 in. x 4 in. Lag Bolts
1-1/2 in. Entrance Cap
Heavy Duty Rack
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 4 in. Lag Bolts
1-1/2 in. Male Adaptor
Entrance Cap
Heavy Duty Rack
2 in. Male Reducer
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 5 in. Lag Bolts
Entrance Cap
Heavy Duty Rack
2 in. Male Reducer
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 5 in. Lag Bolts
Service Mast Ground Clamp
Entrance Cap
Heavy Duty Rack
Flange c/w Neoprene Collar
Strap c/w 3/8 in. x 5 in. Lag Bolts
Mast Coupler
Entrance Cap
Heavy Duty Rack
2 in. Male Reducer
Strap c/w 3/8 in. x 4 in. Lag Bolts
Cat. No.
KIT-100HDM
Qty.
1
3
1
3
1
KIT-200-PVC
2
1
1
KIT-200AM-CP
3
2
1
1
KIT-200MH-CP
3
2
1
Consists of
MM104
MM140M
MM201
MM503
Description
Entrance Cap
1-1/4 in. Male Reducer
Heavy Duty Rack
Flange c/w Steel Collar
MM255
Strap c/w 3/8 in. x 5 in. Lag Bolts
SS401-E
E998J
E997JC
PH20
E943J
CI1716
E986J
CIDUCT1
UA9AJCB-UPC
MM202
MM201
MM505N
MM200M
MM251
E943J
CI1716
E986J
DUCT SEAL
Spool Rack
2 in. Entrance Cap
2 in. Strap
2 in. Hub PVC
2 in. Male Adaptor
2 in. Locknut
2 in. LB Type
Duct Seal
2 in. PVC Elbow
2 in. Entrance Cap
Spool Rack
Floor Flange
2 in. Male Reducer
Strap c/w 3/8 in. x 4 in. Lag Bolts
2 in. Male Adaptor
2 in. Locknut
2 in. Entrance Cap
Duct Seal
UA9AJCB-UPC
2 in. PVC Elbow
MM202
MM201
MM505N
MH200
MM251
E943J
CI1716
E986J
CIDUCT1
UA9AJCB-UPC
2 in. Entrance Cap
Spool Rack
Roof Flange
2 in. Mast Coupler
Strap c/w 3/8 in. x 4 in. Lag Bolts
2 in. Male Adaptor
2 in. Locknut
2 in. Entrance Cap
Duct Seal
2 in. PVC Elbow
D57
Meter Sockets
Service Masts
Mast Kits Suitable for Quebec and for all Regions
KIT-200-PVC – Quebec
Cat. No.
Qty.
Consists of
Description
This mast kit is used in conjunction with 1-1/4 in. rigid conduit
1
3
1
KIT-200-PVC
2
1
SS401-E
E998J
E997JC
PH20
E943J
CI1716
E986J
CIDUCT1
UA9AJCB-UPC
Spool Rack
2 in. Entrance Cap
2 in. Strap
2 in. Hub PVC
2 in. Male Adaptor
2 in. Locknut
2 in. LB Type
Duct Seal
2 in. PVC Elbow
Consists of
Description
KIT-200AM-CP – Quebec
Cat. No.
Qty.
This mast kit is used in conjunction with 2 in. rigid conduit
1
3
KIT-200AM-CP
2
1
MM202
MM201
MM505N
MM200M
MM251
E943J
CI1716
E986J
CIDUCT1
UA9AJCB-UPC
2 in. Entrance Cap
Spool Rack
Roof Flange
2 in. Male Reducer
2 in. Pipe Strap (c/w Lag Screws)
2 in. Male Adaptor
2 in. Locknut
2 in. Entrance Cap
Duct Seal
2 in. PVC Elbow
Consists of
MM202
MM201
MM505N
MH200
MM251
E943J
CI1716
E986J
CIDUCT1
UA9AJCB-UPC
Description
2 in. Entrance Cap
Spool Rack
Roof Flange
2 in. Mast Coupler
2 in. Pipe Strap c/w Lag Screws 3/8 x 4 in.
2 in. Male Adaptor
2 in. Locknut
2 in. Entrance Cap
Duct Seal
2 in. PVC Elbow
Consists of
Description
KIT-200MH-CP – Quebec
Cat. No.
KIT-200MH-CP
Qty.
1
1
1
1
3
2
2
1
1
1
KIT-400MH – For all Regions
Cat. No.
Qty.
This mast kit is used in conjunction with 4 in. rigid conduit
KIT-400MH
D58
1
1
1
1
3
CIEFA-4
MM801
MM806N
MH40
CI1532
4 in. Entrance Head
Heavy Duty Spool Rack
Roof Flange
4 in. Mast Coupler
Pipe Strap c/w Lag Screws (6) 3/8 x 5 in.
w w w. t n b. c a
Meter Sockets
Service Masts
Mast Kits Suitable for New Brunswick, Nova Scotia,
Newfoundland and Prince Edward Island
New Brunswick
Cat. No.
Qty.
1
1
3
1
1
3
1
1
1
1
3
1
1
1
1
3
1
1
1
3
1
1
1
3
1
1
1
3
1
KIT-100
KIT-100NBMH
KIT-200
KIT-200MH
KIT-206NBMH
KIT-200NBMH
KIT-106NBMH
Nova Scotia
Consists of
MM104
MM140M
MM251
MM505N
MM104
MM251
MH200
MM505N
MM202
MM200M
MM251
MM505N
MM202
MM201
MH200
MM255
MM505N
MM202
MH200
MM251
MM506N
MM202
MH200
MM251
MM505N
MM104
MM506N
MM251
MH200
Description
Entrance Cap
1-1/4 in. Male Reducer
Strap c/w 3/8 in. x 4 in. Lag Bolts
Flange c/w Neoprene Collar
Entrance Cap
Strap c/w 3/8 in. x 4 in. Lag Bolts
Mast Coupler
Flange c/w Neoprene Collar
Entrance Cap
2 in. Male Reducer
Strap c/w 3/8 in. x 4 in. Lag Bolts
Flange c/w Neoprene Collar
Entrance Cap
Heavy Duty Spool Rack
Mast Coupler
Strap c/w 3/8 in. x 5 in. Lag Bolts
Flange c/w Neoprene Collar
Entrance Cap
Mast Coupler
Strap c/w 3/8 in. x 4 in. Lag Bolts
All Neoprene Roof Flange
Entrance Cap
Mast Coupler
Strap c/w 3/8 in. x 4 in. Lag Bolts
Flange c/w Neoprene Collar
Entrance Cap
All Neoprene Roof Flange
Strap c/w 3/8 in. x 4 in. Lag Bolts
Mast Coupler
Cat. No.
KIT-100MN
KIT-100
KIT-100NSMH
KIT-200AM
KIT-200
KIT-200NSMH
Cat. No.
KIT-100MH
KIT-100NBMH
KIT-205LDMH
Qty.
1
1
1
3
1
1
3
1
1
1
1
3
1
1
Consists of
MH200
MM104
MM101
MM251
MM505N
MM104
MM251
MH200
MM505N
MM202
MM101
MM251
MH200
MM505N
Description
Mast Coupler
Entrance Cap
Light Duty Spool Rack
Strap c/w 3/8 in. x 4 in. Lag Bolts
Flange c/w Neoprene Collar
Entrance Cap
Strap c/w 3/8 in. x 4 in. Lag Bolts
Mast Coupler
Flange c/w Neoprene Collar
Entrance Cap
Light Duty Spool Rack
Strap c/w 3/8 in. x 4 in. Lag Bolts
Mast Coupler
Flange c/w Neoprene Collar
KIT-100MH
Qty.
1
1
3
1
1
1
KIT-106NBMH
KIT-200MH
KIT-200NBMH
KIT-206NBMH
w w w. t n b. c a
1
1
1
3
1
1
1
3
1
1
4
1
1
1
1
3
1
1
1
1
3
1
1
1
3
1
Consists of
MM104
MM140M
MM101
MM255
MM505N
MM104
MM140M
MM251
MM505N
MM104
MM251
MM505N
MH200
MM202
MM201
MM255
MM200M
MM505N
MM202
MM200M
MM251
MM505N
MM202
MH200
MM251
MM505N
Description
Entrance Cap
1-1/4 in. Male Reducer
Light Duty Spool Rack
Strap c/w 3/8 in. x 5 in. Lag Bolts
Flange c/w Neoprene Collar
Entrance Cap
1-1/4 in. Male Reducer
Strap c/w 3/8 in. x 4 in. Lag Bolts
Flange c/w Neoprene Collar
Entrance Cap
Strap c/w 3/8 in. x 4 in. Lag Bolts
Flange c/w Neoprene Collar
Mast Coupler
Entrance Cap
Heavy Duty Spool Rack
Strap c/w 3/8 in. x 5 in. Lag Bolts
2 in. Male Reducer
Flange c/w Neoprene Collar
Entrance Cap
2 in. Male Reducer
Strap c/w 3/8 in. x 4 in. Lag Bolts
Flange c/w Neoprene Collar
Entrance Cap
Mast Coupler
Strap c/w 3/8 in. x 4 in. Lag Bolts
Flange c/w Neoprene Collar
Prince Edward Island
Newfoundland
Cat. No.
Qty.
3
1
1
1
1
1
3
1
1
1
3
1
1
1
3
1
Consists of
MM104
MM101
MM251
MM505N
MH200
MM104
MM251
MH200
MM506N
MM202
MM201
MH200
MM255
MM505N
MM202
MH200
MM251
MM505N
MM202
MH200
MM251
MM506N
Description
Entrance Cap
Light Duty Spool Rack
Strap c/w 3/8 in. x 4 in. Lag Bolts
Flange c/w Neoprene Collar
Mast Coupler
Entrance Cap
Strap c/w 3/8 in. x 4 in. Lag Bolts
Mast Coupler
All Neoprene Roof Flange
Entrance Cap
Heavy Duty Spool Rack
Mast Coupler
Strap c/w 3/8 in. x 5 in. Lag Bolts
Flange c/w Neoprene Collar
Entrance Cap
Mast Coupler
Strap c/w 3/8 in. x 4 in. Lag Bolts
Flange c/w Neoprene Collar
Entrance Cap
Mast Coupler
Strap c/w 3/8 in. x 4 in. Lag Bolts
All Neoprene Roof Flange
D59
Meter Sockets
Pole Line Hardware
Heavy-Duty Spool Rack (200 A)
Cat. No.
No. of Wires
Overall Length
(in.)
SS401E
SS802E
SS803E
SS804E
1
2
3
4
9-1/2
17-1/2
25-1/2
33-1/2
Weight (100 pcs)
lb.
kg
300
136.3
520
236.3
780
354.5
1040
472.7
Std. Pkg.
10
5
Racks are made of 1 in. x 1 in. x 1/8 in. angle iron, assembled complete with 5/8 in. diameter rod and 3/16 in. diameter brass
cotter pin. All ferrous parts are hot dip galvanized. Insulator cat. no. IB135 must be ordered separately (included in SS401E only).
SS401E - SS802E - SS803E - SS804E
Heavy-Duty Spool Rack (400 A)
Cat. No.
No. of Wires
Overall Length
(in.)
MM801
1
3
Weight (100 pcs)
lb.
kg
360
163.2
Std. Pkg.
10
MM801
Medium-Duty Spool Rack (100 A)
Cat. No.
SS18
No. of Wires
Overall Length
(in.)
1
6-1/2
Weight (100 pcs)
lb.
kg
150
68.1
Std. Pkg.
25
Medium duty spool rack is furnished complete with cat. no. IB134 insulator.
All ferrous parts are hot dip galvanized.
SS18
Tripods (200 A)
96 in.
Cat. No.
No. of Wires
603TH*
604TH
3
—
Weight (100 pcs)
lb.
kg
4000
1818.1
3800
1727.2
Std. Pkg.
1
1
Type “T” (medium duty) is constructed of 1 in. x 1 in. x 1/8 in. angle iron. Type “TH” (heavy duty) is constructed
of 1-1/4 in. x 1-1/4 in. x 3/16 in. angle iron. All ferrous parts are hot dip galvanized.
* Complete with IB400.
72 in.
24
in.
603TH-604TH
D60
w w w. t n b. c a
Meter Sockets
Pole Line Hardware
Tripod insulator (200 A)
Cat. No.
Height
(in.)
Overall Dia.
(in.)
IB400
3-1/2
3-1/4
Weight (100 pcs)
lb.
kg
125
56.8
Std. Pkg.
25
IB400
Insulators (100–200 A)
Cat. No.
IB134 (100 A)
IB135 (200 A)
Height
(in.)
2
3
Ampere
100
200
Diameter
(in.)
2-1/4
3
Weight (100 pcs)
lb.
kg
40
18.1
115
52.2
Hole Dia.
(in.)
9/16
13/16
Std. Pkg.
100
50
Porcelain insulator securely held in the hot galvanized steel clevis by a cotter pin.
IB134 - IB135
Screw type insulator (100 A)
Cat. No.
IB900
Insulator Length
(in.)
3
Pull Out
Strength
1500 lb.
Weight (100 pcs)
lb.
kg
87
39.5
Std. Pkg.
25
Porcelain insulator securely held in the hot galvanized steel clevis by a cotter pin.
IB900
Light-Duty Clevis (100 A)
2-1/8
in.
Cat. No.
2-1/8 in.
AN422
AN422KIT
AN423
Weight (100 pcs)
lb.
kg
Mounting Hole
Std. Pkg.
11/16 in. round
90
40.9
11/16 in. round c/w bolts and washers
–
–
25
1
9/16 in. x 9/16 in. square
90
40.9
25
Add suffix “NI” if insulator is not required. Constructed of 1/8 in. x 1 in. flat mild steel, has 3/8 in. diam. pin and C/W No. IB134 insulator,
mounting hole as per table above. All ferrous parts are hot dip galvanized.
AN422 - AN422KIT - AN423
Clevis (200 A)
2-5/8
in.
Cat. No.
AN424
2-1/8 in.
Weight (100 pcs)
lb.
100
kg
45.4
Std. Pkg.
25
Add suffix “NI” if insulator is not required. Constructed of 1/8 in. x 1-1/4 in. flat mild steel, has 3/8 in. diam. pin and C/W No. IB134
insulator, 3/8 in. round mounting hole. All ferrous parts are hot dip galvanized.
AN424
w w w. t n b. c a
D61
Meter Sockets
Pole Line Hardware
Heavy-Duty Clevis (200 A)
4 in.
Cat. No.
AN428S
3-1/4 in.
Weight (100 pcs)
lb.
262
kg
119
Std. Pkg.
25
Add suffix “NI” if insulator is not required. Constructed of 3/16 in. x 1-1/2 in. flat mild steel, has 5/8 in. diam. pin and C/W No.
IB135 insulator, 11/16 in. round mounting hole. All ferrous parts are hot dip galvanized.
AN428S
Heavy-Duty Clevis (200 A)
4 in.
Cat. No.
AN428
3-1/4 in.
Weight (100 pcs)
lb.
kg
350
159
Std. Pkg.
5
Add suffix “NI” if insulator is not required. Constructed of 1/4 in. x 2 in. flat mild steel, has 5/8 in. diam. pin and C/W No. IB135
insulator, 11/16 in. round mounting hole. All ferrous parts are hot dip galvanized.
AN428
Heavy-Duty Flat Mount Triplex Cable Rack (200 A)
Cat. No.
AN117
3-1/4 in.
Weight (100 pcs)
lb.
290
kg
130
Std. Pkg.
10
Heavy duty wall rack constructed of 1/8 in. steel, C/W 2 mounting holes 1/2 in., C/W No. IB135 insulator.
All ferrous parts are hot dip galvanized.
AN117
Light-Duty Flat Mount Triplex Cable Rack (100 A)
Cat. No.
AN122
2-1/2 in.
Weight (100 pcs)
lb.
160
kg
70
Std. Pkg.
10
Light duty wall rack constructed of 1/8 in. steel, C/W 2 mounting holes 1/2 in., C/W No. IB134 insulator.
All ferrous parts are hot dip galvanized.
AN122
D62
w w w. t n b. c a
Meter Sockets
Pole Line Hardware
Clevis (100 A)
Cat. No.
AL425
2-1/8 in.
Weight (100 pcs)
lb.
162
kg
73.6
Std. Pkg.
20
Add suffix “NI” if insulator is not required. Constructed of 3/16 in. x 1-1/2in. flat mild steel, has 1/2” diam. pin and C/W
No. IB134 insulator, 11/16 in. round mounting hole. All ferrous parts are hot dip galvanized.
4-3/16 in.
AL425
Clevis (200 A)
Cat. No.
AL426
3-1/4 in.
Weight (100 pcs)
lb.
262
kg
119
Std. Pkg.
10
Add suffix “NI” if insulator is not required. Constructed of 3/16 in. x 1-1/2 in. flat mild steel, has 5/8 in. diam. pin and C/W
No. IB135 insulator, 11/16 in. round mounting hole. All ferrous parts are hot dip galvanized.
4-3/16 in.
AL426
Clevis (200 A)
Cat. No.
AU427
3-1/4 in.
Weight (100 pcs)
lb.
265
kg
120.4
Std. Pkg.
10
Add suffix “NI” if insulator is not required. Constructed of 1-1/4 in. x 1/2 in. x 1/8 in. steel channel, has 5/8 in. diam. pin
and C/W No. IB135 insulator, 11/16 in. round mounting hole. All ferrous parts are hot dip galvanized.
3-3/4 in.
AU427
Clevis (200 A)
Cat. No.
AU429
3-1/4 in.
Weight (100 pcs)
lb.
240
kg
109
Std. Pkg.
10
Add suffix “NI” if insulator is not required. Constructed of 1 in. x 1/2 in. x 1/8 in. steel channel, has 5/8 in. diam.
pin C/W No. IB135 insulator, 11/16 in. square hole. All ferrous parts are hot dip galvanized.
3-3/4 in.
AU429
w w w. t n b. c a
D63
Meter Sockets
Pole Line Hardware
Clevis (100 A)
Cat. No.
SW409
2-1/4 in.
Weight (100 pcs)
lb.
100
kg
45.4
Std. Pkg.
25
Add suffix “NI” if insulator is not required. Constructed of 1/8 in. x 1 in. curved mild steel, has 3/8 in. diam. swivel type
pin C/W No. IB134 insulator, 2 mtg. holes 7/16 in. round. All ferrous parts are hot dip galvanized.
SW409
Clevis (100 A)
10 in.
Cat. No.
SW410
6 in.
Weight (100 pcs)
lb.
180
kg
81.8
Std. Pkg.
20
Add suffix “NI” if insulator is not required. Undereave/off the wall bracket constructed of 3/16 in. x 1-1/2 in. flat mild steel,
C/W No. IB132 insulator. Three 3/8 in. round mtg. holes. All ferrous parts are hot dip galvanized.
4 in.
SW410
Clevis (100 A)
Cat. No.
2 in.
SW411
2-1/4 in.
Weight (100 pcs)
lb.
125
kg
56.8
Std. Pkg.
20
Add suffix “NI” if insulator is not required. Constructed of 1/8 in. x 3/4 in. curved mild steel, has 3/8 in. diam. swivel type
pin C/W No. IB134 insulator, strong 1/4 in. angle bracket, 11/16 in. round mtg. hole. All ferrous parts are hot dip galvanized.
2-1/2 in.
SW411
Clevis (100 A)
Cat. No.
SW411S
4-1/2 in.
2-1/4 in.
Weight (100 pcs)
lb.
125
kg
56.8
Std. Pkg.
20
Add suffix “NI” if insulator is not required. Constructed of 1/8 in. x 3/4 in. curved mild steel, has 3/8 in. diam. swivel type
pin C/W No. IB134 insulator, strong 1/4 in. bracket, 11/16 in. round mtg. hole. All ferrous parts are hot dip galvanized.
SW411S
D64
w w w. t n b. c a
Meter Sockets
Pole Line Hardware
Clevis (100 A)
Weight (100 pcs)
Cat. No.
lb.
100
SW412
Std. Pkg.
kg
45.4
10
Add suffix “NI” if insulator is not required. Undereave/off the wall bracket constructed of 3/16 in. x 1-1/2 in. steel, C/W
No. IB134 insulator. Three 3/8 in. round mtg. holes. All ferrous parts are hot dip galvanized.
SW412
Clevis (100 A)
Weight (100 pcs)
Cat. No.
lb.
140
SW412-MH
Std. Pkg.
kg
63.5
20
Add suffix “NI” if insulator is not required. Constructed of 3/16 in. x 1-1/2 in. steel, has 5/8 in. diam. pin and C/W No.
IB134 insulator. 11/16 in. round mtg. hole. All ferrous parts are hot dip galvanized.
SW412-MH
Anti-Vibration Kit for Spool Rack
Weight (100 pcs)
lb.
kg
Cat. No.
Description
B3/8-6
2 bolts 3/8 x 6 in. long c/w 1 washer,
1 lockwasher and 1 nut finished hot galv.
100
45.35
Std. Pkg.
5
Add suffix “NI” if insulator is not required. Constructed of 1-1/4 in. x 1/2 in. x 1/8 in. steel channel, has 5/8 in. diam. pin
and C/W No. IB135 insulator, 11/16 in. round mounting hole. All ferrous parts are hot dip galvanized.
Québec Construction Code, Chapter V – Electricity,
Article 6-112 (6) requires that the spool rack be tightly
bolted and attached to structural members of a minimum thickness of 88mm overall, if the framed structure
is made of wood.
PLAN VIEW
ELEVATION VIEW
Minimum
38 mm
Hydro-Québec, Low-Voltage Electrical Service, Standard
E21-10, Article 2.2.1, 2.2.2 and Blue Book read as follows:
Bolt (mandatory)
Minimum
38 mm
Lag screw (prohibited)
Note: Interior insulation and exterior wall are not shown for more clarity. Figure 2: Spool rack installation (wooden structure).
Source: Régie du bâtiment du Québec. Can also be used in all Provinces
w w w. t n b. c a
2.2.1 SUPPLY AND INSTALLATION
The master electrician shall, at the customer’s expense,
supply and install the spool rack in accordance with
Code requir ments and with the recommendations of
the Régie du bâtiment du Québec, particularly to avoid
any problem due to vibrations. The customer retains
ownership of the spool rack.
2.2.2 LOCATION
The spool rack may be attached to the exterior wall of
a building or to a customer pole, service mast or other
support structure. The master electrician shall ensure
that the service loop is secured firmly to the building in
a location not conducive to vibrations, and shall strengthen the structure, if necessary, at the customer’s
expense. The location must also allow the meter to be
installed in a readily accessible place.
D65
Meter Sockets
Pole Line Hardware
Machine Bolts
Cat. No.
F
F
H
G
BM506
BM508
BM510
BM512
BM514
BM516
BM518
BM520
F
Diam. (po)
G
Long. (po)
H
Min. (po)
6
1-1/2
8
4
10
5/8
Weight (100 pcs)
lb.
kg
Std. Pkg.
70
31.8
86
39.0
102
46.3
12
115
52.2
14
130
59.0
145
65.9
18
160
72.7
20
175
79.5
16
6
25
50
Lag Screws
Cat. No.
T102L
T103
T203
T302
T303
T304
T305
T306
T308
T310
T404-CM
T405
T406
T505
D66
F
Diam. (po)
1/4
5/16
3/8
G
Long. (po)
2-1/2
Weight (100 pcs)
lb.
kg
3
1.3
4
1.8
6
2.7
2
7
3.1
3
10
4.5
4
11
5.0
5
14
6.3
6
17
7.7
3
Std. Pkg.
8
22
10.0
10
27
12.2
4
22
10.0
1/2
5
27
12.2
6
31
14.0
5/8
5
45
20.4
100
50
25
10
50
25
w w w. t n b. c a
Meter Sockets
Pole Line Hardware
“U” Cable Guards and Straps
Cat. No.
Width
(in.)
Length
(ft.)
Weight (100 pcs)
lb.
kg
Size
Std. Pkg.
Straight
UG8114
UG8214
UG8314
Flared
UGF8114
UGF8214
UGF8314
Strap
SUG114
SUG214
SUG314
L
1-1/4
2-1/4
3-1/4
8
–
760
1300
2000
345
590
909
5
1-1/4
2-1/4
3-1/4
8
–
760
1300
2000
345
590
909
5
–
–
1-1/4
2-1/4
3-1/4
15
24
60
6.8
11.0
27.0
10
Hot dip galvanized 14 gauge steel. For nonmetallic version (PV-Mold™), refer to pp. D73–D77.
W
Guy Clamps
Cat. No.
GC902
GC904
GC906
Bolt
Qty.
2
3
Size
1/2
5/8
Length
(in.)
3-1/4
5-7/8
6
Range
(in.)
1/4–7/16
5/16–1/2
Weight (100 pcs)
lb.
kg
130
59.0
224
101.3
274
124.5
Std. Pkg
50
25
Eye Nut
Cat. No.
Eye Dimensions
(in.)
Weight (100 pcs)
lb.
kg
K58
1-5/16 x 1-11/16
70
31.8
Std. Pkg.
50
3-1/2 in.
9/16 in.
1-1/4 in.
1-5/16 in.
1-11/16 in.
Drop forged, hot galvanized, tapped 5/8 in.
2-7/16 in.
w w w. t n b. c a
1-1/4 in.
D67
Meter Sockets
Pole Line Hardware
Guy Hooks
Weight (100 pcs)
lb.
kg
Cat. No.
Bolt Size
(in.)
CH912
K133A
5/8
90
40.9
50
5/8–3/4
118
53.6
25
CH912
K133A
Std. Pkg.
Prevent the guy from slipping down, when the pole is guyed at a sharp angle.
Made of half oval steel, the round side serving as protection to the strands.
Iron guy hook for use with 5/8 in. or 3/4 in. bolt. Equipped with teeth to imbed in the wood fibres.
K133A
Screw Anchor
Cat. No.
Rod Dia.
(in.)
Length
(ft.)
Plate Dia.
(in.)
TS346
3/4
5.6
6
Weight (100 pcs)
lb.
kg
1050
Std. Pkg.
477.2
2
Installed by placing a rod into the heavy forged oval eye to screw the anchor into the ground.
TS346
Anchor Rods
Cat. No.
Rod Dia.
(in.)
Length
(ft.)
AR586
AR347
5/8
6
3/4
7
Type
Double thimble
Weight (100 pcs)
lb.
kg
750
340.9
1320
600.0
Std. Pkg.
5
AR586 - AR347
Expanding Anchor
Cat. No.
EA08
Hole Size (in.)
Required
Area
(sq. in.)
Rod Dia.
(in.)
8
135
5/8 - 3/4
Weight (100 pcs)
lb.
kg
950
431.8
Std. Pkg.
5
These heavy duty steel anchors have 8 blades that expand to form a square, with equalized load distribution all around the anchor.
EA08
D68
w w w. t n b. c a
Meter Sockets
Pole Line Hardware
Oval Eye Bolt
Cat. No.
Description
H
BO506
BO508
BO510
BO512
G
BO506-508-510-512
Oval eye bolt
F Dia.
(in.)
G Length
(in.)
H Min.
(in.)
6
3
8
5/8
10
4
12
Weight (100 pcs)
lb.
kg
Std. Pkg.
122
55.4
50
136
61.8
25
150
68.1
25
168
76.3
25
W
Guy Strain Insulator
Note: Made of Porcelain
L
Cat. No.
Length (ft.)
504WGS
506WGS
Dia. (in.)
4-1/4
2-7/8
5-1/2
3-3/8
Weight (100 pcs)
lb.
kg
1.0
Std. Pkg.
0.45
1
504WGS-506WGS
Guy Wire Guard
Cat. No.
Colour
Length (ft.)
2YG
Yellow
6.7
Weight (100 pcs)
lb.
kg
3.35
1.46
Std. Pkg.
10
2YG
Type W – Aluminum Service Wedge Clamps for use with
ACSR, Aluminum, AAAC Conductors
• For dead-ending self-supporting drop wire
• Saves conductor – drop wire may be cut to exact length
• Can be attached to bare neutral at any point in the span
• Adjustments in drop wire sag are easily made
• Grips ACSR, AAAC, or aluminum conductors
“FC” Flexible Bail
(Bail Length – 11-1/2 in.)
Rigid Stainless Steel Bail
(Bail Length – 6-1/2 in.
Cat. No.
D
L
W-1 Series aluminum
wedge and slider
W62-1
W62-1FC
W20-1
W20-1FC
W40-1*
W40-1FC*
ACSR
Conductor Range
AL
AAAC
Dimensions (in.)
D
L
Typical Tensile Values
Conductor Value (lb.)
2–6
1 str. – 6 sol.
2–6
2-3/8 flex.
12, 17-1/2
2 6 x 1 ACSR
1200
2–6
1 str. – 6 sol.
2–6
2-3/8 flex.
12, 17-1/2
2 6 x 1 ACSR
1200
1/0–4
2/0 str. – 2 sol.
1/0–4
2-3/8 flex. 12-1/2, 18-1/2 1/0 6 x 1 ACSR
1800
1/0–4
2/0 str. – 2 sol.
1/0–4
2-3/8 flex. 12-1/2, 18-1/2 1/0 6 x 1 ACSR
1800
4/0–2/0
4/0 str. – 2 sol.
4/0–2/0
2-3/8 flex. 12-3/4, 18-1/2 4/0 6 x 1 ACSR
1900
4/0–2/0
4/0 str. – 2 sol.
4/0–2/0
2-3/8 flex. 12-3/4, 18-1/2 4/0 6 x 1 ACSR
1900
* W40 series clamps rated 850 lb. ultimate tension for 1/0 ACSR, AL, or AAAC.
w w w. t n b. c a
D69
Meter Sockets
Carlon Nonmetallic Conduits
®
Schedule 40 PVC Rigid Nonmetallic Conduits
Product Specifications
Certified for underground applications encased in concrete or direct burial.
Also for use in exposed or concealed above ground applications.
• Sunlight resistant
• Rated for use with 75˚C conductors
• Superior weathering characteristics
• Meets CSA Standard
• 3/4 in. – 4 in. are FT-4 Rated
Guy Strain Insulator
Cat. No.
10 ft.
49009CC-010
49010CC-010
49011CC-010
Nom. Size
(in.)
Std. Crate Qty.
10 ft.
1-1/4
3300
1-1/2
1800
2
1400
Std. Bundle Qty.
10 ft.
Wt. Per
100 ft.
Dimensions
O.D.
I.D.
46
1.660
1.380
50
55
1.900
1.610
73
2.375
2.067
Acceptable Dimensions in Inches of CSA Listed Integral Bell
A
Nom.
Size (in.)
C
1-1/4
1-1/2
2
A
At Entrance
Maximum
Minimum
1.689
1.665
1.930
1.906
2.405
2.381
B
At Bottom
Maximum
Minimum
1.667
1.643
1.906
1.882
2.381
2.357
C
Socket Depth
Maximum
Minimum
3.938
1.062
2.00
1.125
For more information or for other sizes, contact your Regional Sales Office
B
D70
w w w. t n b. c a
Meter Sockets
Carlon Nonmetallic Conduits
®
Schedule 40 PVC Rigid Nonmetallic Conduits
E
F
Service Entrance Caps
3 Places
Knockouts
for
conductors
«H»
«G»
Cat. No.
Size
(in.)
Std. Ctn.
E998G
E998H
E998J
1-1/4
1-1/2
2
20
10
5
Dimensions (in.)
F
G
E
H
3.52
0.74
0.71
0.50
4.26
0.83
0.78
0.56
Meter Offset
Cat. No.
Size (in.)
1-1/4
E995G
Std. Ctn.
20
Offset
0.758
A (in.)
4.230
A
2 Hole Nonmetallic Clamps
C
D
J
2 Places
B
G
F
A
E
H
Cat. No.
Sizes
in. (mm)
E977GC
1-1/4
(35)
E977HC
Std.
Ctn.
(lb.)
Dimensions in. (mm)
A
B
C
D
E
F
G
H
J
50
1.714
(43.5)
2.68
(68.0)
3.28
(83.3)
0.64
(16.2)
0.15
(3.8)
0.83
(21.0)
1.687
(42.8)
1.89
(48.0)
0.320
(8.1)
1-1/2
(41)
50
1.920
(48.7)
2.82
(71.6)
3.44
(87.3)
0.70
(17.7)
0.15
(3.8)
0.97
(24.6)
1.930
(49.0)
2.12
(53.8)
0.312
(7.9)
E977JC
2
(53)
25
2.54
(64.5)
3.54
(89.9)
4.18
(106.1)
0.76
(19.3)
0.16
(4.0)
1.05
(26.6)
2.29
(58.1)
2.49
(63.2)
0.315
(8.0)
E977LC-CAR
3
(78)
20
3.47
(88.2)
5.00
(127.0)
6.00
(152.4)
1.00
(25.4)
0.20
(5.08)
1.74
(44.3)
3.48
(88.4)
3.70
(94.0)
0.360
(9.14)
Nonmetallic clamps offer the same chemical resistance as Carlon nonmetallic conduits for a complete, corrosion resistant
system. UV inhibited for use in direct sunlight. For more information or other sizes, contact your Regional Sales Office
Schedule 40 Elbows – Std. Radius
Cat. No.
Size (in.)
1-1/4
1-1/2
2
UA9AGCB-UPC
UA9AHCB-UPC
UA9AJCB-UPC
90°
Belled End Std. Ctn.
20
25
20
Available in plain and integral belled end for use with nonmetallic solvent weld fittings. Custom elbows available on request.
R
90° Elbow
Integral Belled End Dimensions
A
C
B
w w w. t n b. c a
Trade Size
(in.)
1-1/4
1-1/2
2
A
At Entrance (in.)
Max.
Min.
1.689
1.665
1.930
1.906
2.405
2.381
B
At Bottom (in.)
Max.
Min.
1.667
1.643
1.906
1.882
2.381
2.357
C
Socket Depth (in.)
Max.
Min.
0.938
2.000
1.062
1.125
D71
Meter Sockets
Carlon Nonmetallic Conduits
®
Rigid Nonmetallic Conduits
Conduit Bodies – Type LB
Q
L1
L2
C
W
Cat. No.
Size
(in)
Std.
Ctn.
C
Typical
(in.)
E986G
E986H
E986J
1-1/4
1-1/2
2
10
1-3/32
Typical (in.)
Max.
L1
(in.)
L2
7-31/32
Max.
H
(in.)
L3
6
6-13/32
9-31/32
2-5/16
7-1/4
Max.
Q
(in.)
Max.
W
(in.)
Vol.
Cu. in.
2-1/2
2-3/4
32.0
3-5/32
3-15/32
63.0
C
1.208
1.155
1.145
1.643
Typical (in.)
S
0.816
0.802
0.825
0.797
L
1.986
2.105
2.093
2.660
H
L3
Male Terminal Adapters
Cat. No.
L
S
OD A
D
B
C
E943G
E943H
E943J
E943L
Size
(in.)
Std.
Ctn.
1-1/4
1-1/2
2
3
50
25
50
45
Typical (in.)
A
B
1.677
1.655
1.918
1.894
2.393
2.369
3.515
3.492
Min. D
(in.)
Max. OD
(in.)
1.345
1.574
1.998
2.989
1.973
2.188
2.713
3.965
For adapting nonmetallic conduits to boxes, threaded fittings, metallic systems.
Male threads on one end, socket end on other.
®
Iberville Steel Locknuts
Cat. No.
Trade Size (in.)
CI1710
CI1712
CI1716
CI1724
1-1/4
1-1/2
2
3
Expansion Fitting
Cat. No.
Size (in.)
Std. Ctn.
Travel Length (in.)
E945L
3
10
8
PVC Conduit to DB/2 Duct Adapter
Cat. No.
CE942RL
D72
Size (in.)
Std. Ctn.
3
1
w w w. t n b. c a
Meter Sockets
Carlon PV-Mold
™
®
Nonmetallic Pole Riser System
Carlon® PV-Mold™ is a nonmetallic pole riser system designed
to protect communications power cable installed on poles.
Product Specifications
• Meets or exceeds requirements outlined in the
National Electric Safety Code (NESC)
• Designed in accordance with NEMA TC-19 specifications
• Ultraviolet, cold temperature and corrosive
atmosphere resistant
• No grounding required
• Belled end fits over each added section or conduit
• Requires no maintenance
• PV-Mold™ acts as an insulator against electrical shock
• Interchangeable parts and accessories to match the needs
of specific requirements
STEEL U-GUARD REQUIRES
GROUNDING STRAPPING AND
DOES NOT HAVE BELLED ENDS.
PV-MOLD™ HAS BELLED ENDS,
FLANGED DESIGN AND DOES NOT
REQUIRE GROUNDING.
Size (in.)
B
Depth of Bell (in.)
1
1-1/2
2
3
4
5
3 – 3-1/4
4 – 4-1/4
4 – 4-1/2
6
5 – 5-1/2
2 – 2-1/4
H
A
C
FLANGED OVERALL LENGTH
10 FT., INCLUDING BELL
Slots are 1/2 in. from side to side, and allow for expansion and contraction. Slot Dimensions: for sizes 2 in. through 6 in. are 5/16 in. wide, 3/4 in. long.
Slot Dimensions: for 1 in. and 1-1/2 in. are 3/16 in. wide, 3/4 in. long. Slot Spacing: 18 in. from center, beginning 6 in. from end.
Cat. No.
Standard Duty
59208N
59211N
59213N
59215N
59216N
Heavy Duty Schedule 40
59010N
59011N
59013N
59015N
59016N
59017N
Size
(in.)
Std. Ctn.
Std. Ctn.
Wt. (lb.)
1
2
3
4
5
294
136
66
65
30
1059
726
761
910
515
1-1/2
2
3
4
5
6
200
136
66
65
30
30
1142
1214
937
1621
870
1160
Dimensions (in.)
A
0.100
0.150
0.145
0.154
0.216
0.237
0.258
0.280
B
C
H
1-5/8
2-3/8
3-1/2
4-1/2
5-1/2
2-3/8
4-1/2
6
6-1/2
7-1/2
1-5/8
2-3/8
3-1/2
4-1/2
5-1/2
2-29/32
2-3/8
3-1/2
4-1/2
5-1/2
6-5/8
3-1/2
4-1/2
6
6-1/2
7-1/2
8-3/4
1-29/32
2-3/8
3-9/32
4-1/2
5-1/2
6-5/8
Actual Impact
@ 0 oC
20 Pound Tup
40 ft. – lb.
100 ft. – lb.
110 ft. – lb.
100 ft. – lb.
150 ft. – lb.
260 ft. – lb.
For more information on PV-Mold™, contact your Regional Sales Office.
w w w. t n b. c a
D73
Meter Sockets
Carlon PV-Mold™
®
PV-Mold™ Installation and Fittings
Polyethylene Vented Boots and Adapters
Note:
1. A field cut may be needed to accommodate different boot or adapter to
Carlon® U-Mold size combinations.
2. Recommendation: 2 sets of mounting holes per boot/fitting. To add mounting holes,
use a 3/8 in. drill bit and drill out where needed.
3. When 3 in. or smaller conduit is being used, it’s recommended that the bottom
(largest section) of the boot or adapter section be buried 2 in. to 3 in. below ground surface.
E
E
A
A
B
A
B
A
B
C
C
B
D
C
D
C
D
E938JR
E938NT
D
E938NRR
E938PRR
Vented Boots
Cat. No.
Size
(in.)
E938JR
E938NT
E938NRR
E938PRR
2x6
4x8
4x6
5x6
A
20.50
21.00
20.87
16.74
Dimensions (in.)
C
6.13
11.34
12.87
10.84
B
4.80
15.00
16.57
3.65
D
6.20
9.76
11.68
11.43
E
–
–
11.43
–
Std. Ctn.
Std. Ctn.
Wt. (lb.)
4
4
6
6
13.5
21.0
26.4
23.2
Adapters
A
A
B
C
D
E939JN
Cat. No.
Size
(in.)
E939JN
E939NR
2x4
4x6
A
11.00
11.00
Dimensions (in.)
B
C
6.75
5.88
6.75
7.08
D
5.07
7.13
Std. Ctn.
Std. Ctn.
Wt. (lb.)
8
6
10.0
11.7
B
C
D
E939NR
B
Cat. No.
Size
(in.)
E939NRT
4x6
C
A
Dimensions (in.)
A
B
C
D
E
19.75
4.25
12.50
8.50
7.40
Std. Ctn.
Std. Ctn.
Wt. (lb.)
63
14.0
E
E939NRT
D74
w w w. t n b. c a
Meter Sockets
®
Carlon PV-Mold™
PV-Mold™ Installation and Fittings –
Polyethylene Vented Boots and Adapter
Duct to Riser Fittings
Cat. No.
Size (in.)
Std. Ctn.
E939NL
E939N
4x3
4x4
15
Std. Ctn.
Wt. (lb.)
5.6
5.3
Backing Plates
A
C
w w w. t n b. c a
B
Cat. No.
Size
(in.)
59111
59113
59115
59116
59117
59111P
59113P
59115P
59116P
59117P
2
3
4
5
6
2
3
4
5
6
Length
(ft)
10
A
1/16
1/16
1/16
1/16
1/16
2.24
3.41
4.37
5.15
5.90
Dimensions (in.)
B
13/16
1-5/16
1-5/16
1-3/4
1-5/8
0.575
0.570
0.562
0.600
1.40
C
2-1/8
3-1/8
4-1/8
5-1/4
6-1/16
0.050
0.060
0.050
0.060
Std. Ctn.
Std. Ctn.
Wt. (lb.)
1
1.2
1.5
3.0
3.1
4.2
1.4
1.5
3.0
3.4
3.9
D75
Meter Sockets
Carlon® PV-Mold™
PV-Mold™ Installation Instructions
Installation is easy with PV-Mold™ Pole Risers:
1. Install ventilator or duct to riser fittings at the base of the pole.
2. Nail backing plate sections to the surface of the pole. Three nail holes are provided in
each section. Place the “U” sections over the cable and backing plate, with belled end
at the bottom, and attach using 1/4 in. lag bolts.
Flanged
Exclusive Bell End
For easy and quick installation.
(No additional coupler required.)
10’ Lengths Safe and light for easy
handling during installation.
Backing Plate
Provides cable isolation from the pole.
Ventilator Fitting
Used for a “chimney”
effect to cool cable
and increase ampacity.
E939JN
E939NRT
Two Riser Fittings
Available
Duct to riser fitting Adapts
duct to PV-Mold™.
E939NR
Field Installation Instructions for Carlon® PV-Mold™ Adapters (for Adapters E939JN, E939NR, E939NRT)
E939JN
To transition from 4 in. Conduit to 2 in. PV-Mold™
Place Adapter over conduit, attach to pole using the top and bottom mounting holes, place PV-Mold™
over top section of Adapter and secure PV-Mold to pole.
To transition from 4 in. Conduit to 3 in. PV-Mold™
Measure 6.3 in. up from bottom (large end) of adapter and cut. Assemble to pole as described above.
™*
To transition from 3 in. Conduit to 2 in. PV-Mold
Measure 4.75 in. up from bottom (large end) of adapter and cut. Assemble to pole as described above.
E939NR
To transition from 5 in. Conduit to 4 in. PV-Mold™
Place Adapter over conduit, attach to pole using the top and bottom mounting holes, place PV-Mold™
over top section of Adapter and secure PV-Mold™ to pole.
To transition from 6 in. Conduit to 5 in. PV-Mold™
Measure 7.25 in. up from bottom (large end) of adapter and cut. Assemble to pole as described above.
To transition from 5 in. Conduit to 5 in. PV-Mold™*
Measure 4.5 in. down from the top of adapter and cut. Assemble to pole as described above.
* For these transitions it is not necessary to cut the Adapter if desired. If the Adapter is not modified, it is recommended that the bottom 3 in. of the Adapter be buried below grade.
E939NRT
To transition from 6 in. Conduit to 4 in. PV-Mold™
Place Adapter over conduit and attach to pole using the top and bottom mounting holes.
Place PV-Mold™ over top section of Adapter and secure PV-Mold™ to pole.
To transition from 6 in. Conduit to 5 in. PV-Mold™
Measure 5.25 in. down from the top of the adapter and cut. Assemble to pole as described above.
™*
To transition from 6 in. Conduit to 6 in. PV-Mold
D76
Measure 9.5 in. up from the bottom of the adapter and cut. Assemble to pole as described above.
w w w. t n b. c a
Meter Sockets
Carlon® PV-Mold™
PV-Mold™ Installation Instructions
E
B
C
D
E938JR
E938NT
E938NRR
E938PRR
Field Installation Instructions for Carlon® PV-Mold™ Adapters.
For Vented Boots (E938JR, E938NT, E938NRR, E938PRR)
E938JR
To transition from 5 in. or smaller Conduit to 2 in. PV-Mold™
To transition from 5 in. or smaller Conduit to 3 in. and larger PV-Mold™
Place Vented Boot over conduit, attach to pole using the top and bottom
mounting holes, place PV-Mold™ over top section of Vented Boot and
secure PV-Mold™ to pole.
For 3 in. PV-Mold™: Measure 3.75 in. from the TOP of the Boot and cut.
Place the Boot over the Conduit and attach to the pole. Place belled end
of PV-Mold™ over the top end of the boot and secure.
For 4 in. and 5 in. PV-Mold™: Measure 12 in. up from the BOTTOM of the Boot and cut. Place the Boot over the conduit and attach to the pole.
Place the Belled end of the PV-Mold™ AGAINST the top edge of the vent protrusion and secure to the pole.
E938NT
To transition from 6 in. to 8 in. Conduit to 4 in. PV-Mold™
Place Boot over conduit and attach to the pole using the mounting holes.
Place PV-Mold™ over top section of Vented Boot and secure to the pole.
It is recommended that for conduit sizes smaller than 8 in., the bottom 3 in. of the boot be buried below grade. The E938NT can also be used to transition multiple smaller conduits to PV-Mold™
E938NRR
To transition from 6 in. or smaller conduit to 4 in. PV-Mold™
Place Vented Boot over conduit and attach to pole using the top and bottom
mounting holes. Place PV-Mold™ over top section of Vented Boot and secure
PV-Mold™ to pole.
To transition from 6 in. or smaller conduit to 5 in. PV-Mold™
Measure 4.125 in. down from the top of the vented boot and cut.
Assemble to pole as described above.
To transition from 6 in. or smaller conduit to 6 in. PV-Mold™*
Measure 8.25 in. down from the top of the vented boot and cut.
Assemble to pole as described above.
E938PRR
To transition from 6 in. or smaller conduit to 5 in. PV-Mold™
w w w. t n b. c a
Assemble to pole as described above.
D77
Meter Sockets
®
E-Z-Ground Grounding Systems
Waterpipe Ground Clamps
Cat.
No.
Ground
Wire Size
Water Pipe Size
#6, #4,
#2 AWG
1/2 in., 3/4 in., 1 or rebar 4-10
1-1/4 in., 1-1/2 in. or 2 in.
2-1/2 in., 3 in. or 3-1/2 in.
4 in., 4-1/2 in. or 5 in.
6 in.
2-TB
3-TB
4
5-TB
6
Ground
Wire Size
Water Pipe Size
Cat. No.
#4–4/0 AWG
1/2 in.–1
1-1/4 in.–2 in.
2-1/2 in.–3-1/2 in.
4 in.–5 in.
6 in.
8 in.
10 in.
12 in.
3902BU*
3903BU*
3904BU*
3905BU*
3906BU*
3907BU*
3908BU*
3909BU*
Cat. No.
3902
3903
3904
3905-TB
3906-TB
3907
3908
3909-TB
Malleable iron crossbar, steel U-Bolt c/w copper cable clamp
with serrations
Material: Steel U-bolt and nut c/w bronzed aluminum cap
and crossbar cadmium plated plus gold chromate finish
3849
#4–4/0 AWG
1/2 in.–1
1-1/4 in.–2 in.
2-1/2 in.–3-1/2 in.
4 in.–5 in.
6 in.
8 in.
10 in.
12 in.
Material: Bronze U-bolt and nut c/w bronzed aluminum cap and
crossbar with a brite dip finish. *UL Listed for Direct Burial
3826
3844
3840-TB
3826*
3846*
3849**
3840-TB•
Water Pipe Size
Ground Clamps for K&L Grade
Copper Tubing Only
Ground Clamps
Cat. No.
Ground
Wire Size
Material
Malleable Iron
Bronze
Brass
Malleable Iron
For armored and unarmoured wires.
Water Pipe,
Copper Tubing Size
Ground
Rod Size
Cat. No.
Ground Wire Size
1/2 in., 3/4 in.
1/2 po–1
3844*
3888**
#8–#4 AWG
1/2 in.–1
1/2 in., 3/4 in. or 1
–
Water Pipe,
Copper Tubing Size
1/2 in.–1
1/2 in.–1 also rebar 4–10
* With Steel Screws. ** UL approved for direct burial. Silicon Bronze Screws
* For unarmoured copper wires #6, #4 AWG. ** For copper and aluminum conductors; for #14 thru
#2 AWG unarmoured copper wires for corrosive and outdoor use. UL approved for direct burial.
• #8 thru #4 AWG. Not CSA Certified.
D78
w w w. t n b. c a
Meter Sockets
®
E-Z-Ground Grounding Systems
Galvanized Grounding Plates
• Made of high-quality steel, hot dip galvanized
• Major time and cost saving vs ground rods
14-3/4 in.
5/8 in.
3-7/8 ± 1/4 in.
9-3/4 in.
2 ± 1/4 in.
Cat. No.
Description
1016TB
Galvanized grounding plate
1016BTB
1016TB-NG*
Wire Range
Std. Pkg.
8 sol. to
4/0 str.
1
Galvanized grounding plate
(complete with JAB34C connector)
Grounding plate (not galvanized)
Grounding plate (not galvanized)
1/4 in.
1016BTB-NG* (complete with JAB34C connector)
* CSA not applicable.
1016TB - 1016BTB
Ground Electrode Boxes
Cat. No.
Description
Pregalvanized Steel
Hot dip galvanized steel
51628
51629
14 gauge steel 10 in. diameter, 12 in. depth.
51628 - 51629
Knurling Dies for 14- & 15-ton Tools
Cat. No.
15508
Description
For 5/8 in. and 3/4 in. ground rods
Used to knurl ground rods in order to increase the pullout value of the compression connection
by as much as 20%
Hand knurling Tool
for all Ground Rods
240-31565-94
w w w. t n b. c a
D79
Meter Sockets
®
E-Z-Ground Grounding Systems
Ground Rods
Galvanized Ground Rods
• Made of high-strength quality cold drawn steel, (1035) hot dip galvanized
• Meets ANSI CI35.30-1979 requirements
• Stainless steel rods are also available (for more detailed information, contact your T&B Regional Sales Office)
Trade Size
in.
1/2
Cat. No.
GR5006
GR6256
GR6258
GR6250
(0.543 – 0.555)
GR6260
(0.625 – 0.640)
GR6250B*
(0.618 – 0.623)
GR7506
GR7508
GR7510
ft.
6
8
5/8
10
6
8
10
3/4
Rod Size (nominal diameter x length)
mm
m
12.7
1.8
1.8
2.4
15.8
19.0
Plating
Thickness
Standard
Packaging
10
3.0
4 mils
5
1.8
2.4
3.0
Weight per 100
lb.
kg
410
186
600
272
800
363
1000
454
700
1200
1500
318
545
681
* B suffix denotes black iron bare steel ground rod (CSA not applicable). CSA lists rods 1/2 in. and larger, 10 ft. and longer.
Copper Bonded Steel Ground Rods
• All E-Z-Ground® ground rods have a heavy uniform covering of electrolytic copper bonded to a rigid steel core
• Copper ions are forced electrically to join with the steel core, establishing a corrosion-resistant
bond between the copper and the steel
Cat. No.
5005
5006
5008
5010
6256
6258*
6260*
7508*
7510*
1010*
Trade Size
in.
1/2
ft.
5
6
8
10
6
5/8
3/4
1
Rod Size (nominal diameter x length)
mm
m
12.7
1.8
2.4
15.8
Plating
Thickness
Standard
Packaging
10
5 mils
3.0
5
8
10
1.8
8
2.4
10
19.0
25.4
10 mils
3.0
1
Weight per 100
lb.
kg
305
138
370
168
545
247
611
277
508
230
678
308
847
384
992
450
1240
462
2248
1020
* Ground rods are UL listed (425H), except for regular rods shorter than 8 ft. or less than 1/2 in. CSA lists rods 1/2 in. and larger, 10 ft. and longer.
D80
w w w. t n b. c a
Meter Sockets
®
E-Z-Ground Grounding Systems
Ground Rods
Sectional type Ground Rods
• Sectional type ground rods have the same high-quality as regular copper
bonded steel ground rods, and are threaded top and bottom
Trade Size
Cat. No.
in.
5006LS
5008LS
5010LS
6256S
6258S
6260S
7506S
7508S
7510S
1010S
ft.
6
1/2
8
6
8
10
6
8
5/8
3/4
10
1
Rod Size
(nominal diameter x length)
mm
m
12.7
1.8
Plating
Thickness
Thread
Size
10 mils
9/16–12
Standard
Packaging
2.4
15.8
19.0
25.4
5 mils
3.0
1.8
2.4
3.0
10 mils
5/8–11
5
5 mils
3/4–10
10 mils
8–1
1
Weight per 100
lb.
410
546
682
481
670
837
774
992
1040
2248
kg
189
248
309
230
308
384
160
450
562
1020
CSA lists rods 1/2 in. and larger, 10 ft. and longer.
Couplings
• Threaded couplings are made of high-strength, corrosion resistant alloy.
Streamlined design reduces driving friction.
Couplings are tapped for use on all standard threaded sectional rods
Cat. No.
50LC
60C
70C
80C
w w w. t n b. c a
Rod Diameter (in.)
Thread Size
1/2
5/8
3/4
1
9/16 in. – 12 UNS
5/8 in. – 11 UNS
3/4 in. – 10 UNS
1 in. – 8 UNS
Standard Packaging
25
10
Weight per 100 (lb.)
17
25
38
75
D81
Meter Sockets
®
E-Z-Ground Grounding Systems
Ground Rods
Driving Studs
• Driving Studs of high-strength steel
• May be used with all standard threaded couplings
Cat. No.
Rod Diameter (in.)
Thread Size
Standard Packaging
Weight per 100 (lb.)
50LDS*
60DS*+
70DS*
80DS
1/2
9/16 in. – 12 UNS
10
16
5/8
5/8 in. – 11 UNS
25
23
3/4
3/4 in. – 10 UNS
5
35
1
1 – 8 UNS
10
75
* UL Listed
+CSA Certified
Threadless Couplings and Driving Caps for Standard
Copper Bonded Ground Rods
Threadless Couplings
• For joining non-threaded, sectional, copper bonded, steel ground rods
• Coupling is manufactured of a high-strength, corrosion resistant, silicone bronze
Threadless Driving Caps
• Prevent “mushrooming” of ground rod while driving to insure proper fit of coupling
• Driving cap is manufactured of high-strength, hardened steel
Cat. No.
Size (in.)
Dimensions (in.)
Length
Diameter
1/2
3.0
0.78
5/8
2.5
0.69
3/4
3.0
0.97
5/8
4.0
0.88
Standard Packaging
Weight per 100 (lb.)
Threadless couplings
50CNT*
60CNT2*
70CNT*
25
34
31
Driving Caps
60DSNT
10
43
* UL Listed
D82
w w w. t n b. c a
Meter Sockets
®
E-Z-Ground Grounding Systems
Clamps
Type JAB — Ground Rod Clamps
A
Max.
• Cast of high-strength corrosion resistant copper alloy
• Both hex head and socket set screws available
• Long bearing surface of clamp on ground wire
secures ground connection
• UL Listed for direct burial
Cat. No.
Socket Set
Screw
JAB12*
JAB58
JAB34
–
JAB1
B
Nominal Rod Dia.
Hex Head
Bolt
JAB12H
JAB58H
JAB34H
JAB34C
JAB1H
D
Wire Range
(in.)
(mm)
max.
min.
max.
(mm2)
min.
(mm2)
1/2
5/8
3/4
3/4 + 5/8
1
12.7
15.8
19.0
15.8 to 19.0
25.0
2 str.
10 sol.
33.6
5.2
1/0 str.
53.4
8 sol.
3/0 str.
4/0 str.
8.3
95.0
107.1
A
(max.)
Socket
Screw
1-19/32
1-27/32
2
–
2-1/4
C
Dimensions (in.)
Screw
Thread
B
C
Size
UNC-2A
2-3/32
27/32
7/8
2-13/64
29/32
1
7/16-14
11/16
2-11/32
1-1/8 1-1/32
3
1-11/32 1-1/16
A
(max.)
Hex Bolt
D
19/32
11/16
51/64
13/16
1
* CSA not applicable. Add suffix P to Cat. No. for tin-plated clamp
E
Type G — Budget Line Ground Clamps
•
•
•
•
A dependable ground connection offered at a substantial saving
Cast of high-strength corrosion-resistant copper alloy
Hex head bolts
Simplified compact design will make a lasting,
trouble-free connection
• Listed for direct burial
Nominal Rod Dia.
Cat. No.
G3*
G4
G5
G6
A
Max.
B
Wire Range
(in.)
(mm)
max.
3/8
1/2
5/8
3/4
9.5
12.7
15.8
19.0
4 str.
2 str.
min.
max.
(mm2)
33.6
C
Dimensions (in.)
min.
(mm2)
21.1
10 sol.
D
5.2
A
(max.)
Bolt
1-3/8
Screw
Thread Size
UNC-2A
5/16-18
–
3/8-16
B
C
D
E
11/16
27/32
29/32
1-1/16
1/2
27/64
37/64
43/64
13/16
3/8
3/8
1/2
* Not UL Listed and CSA not applicable. Add suffix P to Cat. No. for tin-plated clamp
w w w. t n b. c a
D83
Meter Sockets
E-Z-Ground Grounding Systems
®
Clamps
Cast Bronze Ground Clamps
Connect copper ground wire to water pipe,
copper tubing or ground rods
• High-strength, high-conductivity copper alloy (over 80% copper)
• UL Listed for direct burial
Cat. No.
Water Pipe Size (in.)
JD
J2D
Conductor Range
1/2 to 1
#2 str.–#10 str.
1-1/4 to 2
Type J — Cast Bronze Ground Clamps
For connecting grounding conductor
to water pipe or copper tube
• Cast of high-strength, highly conductive copper alloy
• Screws plated for corrosion resistance
• UL Listed
D84
Cat. No.
Water Pipe
Size (in.)
J
J2BB
J2124
J6
1/2 to 1
1-1/4 to 2
2-1/2 to 4
4-1/4 to 6
Conductor Range
Max.
2 str.
Min.
10 sol.
Dimensions (in.)
A
B
C
2-3/4
2-11/32
23/32
3-3/4
3-1/2
13/16
6
6-5/16
7-1/4
8-1/8
1
w w w. t n b. c a
Meter Sockets
E-Z-Ground Grounding Systems
®
Clamps
Technical Specifications
Cat. No.
Water Pipe Size (in.)
Ground Wire Size (AWG)
min.
max.
Galv.
Steel
Copper
Clad
Ground Clamps (Zinc alloy body/Steel screws)
CI3106
1/2 to 1
10 sol.
2 str.
5/8 to 1*
N/A
10 sol.
2 str.
5/8 to 1*
N/A
2 str.
5/8 to 1*
5/8 to 1
–
–
Ground Clamps (Zinc/Steel)
CI3108
CI3106
1/2 to 1
For connecting grounding conductor to either galvanized steel rod or water pipe.
Ground Clamps (Brass body/brass screws)
CI3110U
1/2 to 1
10 sol.
For connecting grounding conductor to either galvanized steel rod, copper clad or water pipe.
CSA approved for wet locations and for direct burial.
Ground Clamps (Brass body/brass screws)
CI3112U
1-1/4 to 2
10 sol.
2 str.
For connecting grounding conductor to water pipe. CSA approved for wet locations and for direct burial.
CI3108
Ground Rod Clamps (Bronze body/brass screws)
CIGRC58
CIGRC34
N/A
10 sol.
8 sol.
2 str.
1/0 str.
5/8
3/4
5/8
3/4
For connecting grounding conductor to either galvanized steel rod or copper clad rod.
CSA approved for wet locations and for direct burial.
*Reversible.
CI3110U
CI3112U
CIGRC58
w w w. t n b. c a
D85
Meter Sockets
E-Z-Ground® Types of Connectors
used in our Meter Sockets
Tunnel Type Connector
A tunnel type connector is made of aluminum and is ideally suited for grounding and
bonding applications accommodating both copper and aluminum conductor size
#6 AWG to 250 kcmil.
Dual Tunnel Type Connector
A tunnel type connector is made of aluminum and is ideally suited for grounding and
bonding applications accommodating both copper and aluminum conductor size
#6 AWG to 250 kcmil.
Stud Connector
Stud connector is made of zinc plated steel suited for copper or aluminum wire sizes of
#6 AWG to 350 kcmil. Connector is comprised of a stud nut, washer and bell nut.
Lay-in Type Connector
A Lay-in lug is made of aluminum and is ideally suited for grounding and bonding
applications accommodating both copper and aluminum conductor sizes
#14 AWG to 250 kcmil.
Compression Lug
Made of high conductivity wrought copper. Supplied by utility based on wire size
requirements.
D86
w w w. t n b. c a