Derivadores PA e FF INGLES.vp
Transcription
Derivadores PA e FF INGLES.vp
Sensors and Instruments product line - a junction box Junction BOX FOUNDATION FIELDBUS PROFIBUS PA Introduction This catalog contains information about the Profibus PA and Foundation Fieldbus network and has the main goal to show the junction box line for the field instrument. The junction box in this catalog can be passive, with protection against short-circuit or intrinsic safety barrier to protection for up to 8 Ex I field equipment and are available in plastic or metallic material. Profibus PA and Foundation Fieldbus H1 With fieldbus technology, users can have several benefits offered by digital technology and also they can take advantage and get optimization and cost savings with the network distribution bringing safety and reliability in the operations. For the success of any automation and control network, the installation should be done carefully and within the specifications. Precautions and practices are required when designing, installing or testing Profibus PA networks and also adopted for the Foundation Fiedbus H1 network, since the physical layer of these protocols are defined by the same international standard IEC61158-2. Physical Layer The Profibus PA and Foundation Fieldbus H1 protocol is a bi-directional digital communication that allows the network interconnection of several equipment in the field, doing acquisition execution and functions, as well as the procedures and monitoring stations (IHMs) through supervisor softwares. The protocol is based on OSI standard, which has the following layers: Physical Layer, Communication Stack and User Application. We can mention the management in a global way with the applications and advent models based on Function Blocks and Device Descriptions, which recently was standardized according to IEC, the EDDL concept including HART, Foundation Fieldbus and Profibus. The Physical Layer is defined by international standards (IEC, ISA). It receives messages from the Communication Stack and converts them into physical signals in the middle of the fieldbus transmission including and removing preambles, delimiters of beginning and end of messages. The physical layer is based on the IEC61158-2, we can cite the following features: • Data transfer using Manchester code with transmission rate 31.25Kbit / s • For a full signal communication, each product must have at least 9 volts. The H1 physical layer allows that the field equipment is powered by bus. The same pair of wires that feed the equipment also provides the communication signal. • Maximum length is 1900m (trunk and spurs) without repeaters. • Using up to 4 repeaters, the maximum length can be 9.5 km. • Non safety buses in Profibus PA and no external power for trunk line can support the communication of 2 to 32 connected field equipment. • Profibus PA trunk must be able to support various equipments in accordance with intrinsic safety standards and without external power: - Explosion Group IIC: 9 equipments - Explosion Group IIB: 23 equipments Note: It can connect more equipments than the specified, depending on the equipment consumption, the power supply, the intrinsic safety barrier characteristics and the FISCO model. • No interrupting trunk line in operation while connection and disconnection equipments on the spurs. • Topology: bus, tree, star or mixed (a combination of all supported technologies). The FISCO model has the following features: a) a single active element (power supply) on the Fieldbus, located in non-classified area; b) the others equipments are in classified area; c) each field equipment must have minimum consumption of 10mA; d) in Ex ia areas the maximum bus length must be 1000m and 1000m in Ex ib areas; e) For the cable (no cabling restriction until 1000) must take the following parameters: - R´:15 ... 150 Ohm/Km - L´: 0.4 ... 1 mH/Km - C´: 80 ... 200 nF/Km Cable type A: 0.8mm2(AWG18) (*) f) Termination: a. R = 90 ... 100 ohms b. C = 0 ... 2.2 µF. 2 Sense The FISCO concept was optimized allowing a greater number of the field equipments, according to the bus length, taking into account the cable variation parameters (R, ‘L’, C ‘) and using terminators. The concept is in accordance with gases categories and groups that make a simple evaluation of the complete installation involving intrinsic safety. This increased the current capability per segment and the evaluation for users became easier. Furthermore, when purchasing certified products they don't have to worry with calculations, even changing them in operation. H1 - 31.25 Kbit/s Voltage Mode 1 Bit Time 15 to 20mA p-p Receiving Voltage Device Current Fieldbus Device Transmitting CLOCK 1 DATA 0 0.75 to 1.0V p-p + 100 Ohm 1 1 0 0 MANCHESTER BIPHASE-L ENCODING 100 Ohm Power Supply C 0 C Fieldbus Network - Terminator C is sized to pass 31.25Kbit/s Fieldbus signal in voltage mode Manchester code The data transmission of a field equipment is typically 10mA in 31.25Kbit / s at an equivalent resistive load of 50 Ohms creating a modulated voltage signal in 1.0 Volt peak to peak. The power supply can provide 9 to 32 VDC, but in secure applications (IS) it´s necessary to follow the intrinsic safety barriers requirements. USER APPLICATION v COMMUNICATION “STACK” PHYSICAL LAYER t Fieldbus Media (wire) 31.25 Kbit/s Voltage mode The total cable length is the sum of the trunk length (bus master) and all the Spurs (larger than 1m) which the maximum length of the cable type A (*) is the 1900m in unsafe areas. In safe areas the maximum length is 1000 m using cable type A and the spurs cannot exceed 30m. Sense 3 Topology We can have the following topologies below, remembering that these examples are for Profibus PA Network, but for H1 Network they also apply to the Foundation Fieldbus: star, line and point-to-point. Normally, in practice is used a mixed topology: H1 - 31.25 Kbit/s Voltage Mode 1 Bit Time 15 to 20mA p-p Receiving Voltage Device Current Fieldbus Device Transmitting CLOCK 1 DATA 0 USER APPLICATION 0.75 to 1.0V p-p v COMMUNICATION “STACK” + 100 Ohm 100 Ohm Power Supply C 0 1 1 0 0 MANCHESTER BIPHASE-L ENCODING PHYSICAL LAYER C - Terminator C is sized to pass 31.25Kbit/s Fieldbus Network t Fieldbus Media (wire) Star Line Point-to-point Network Cables Several cable types can be used (it is recommended to use the twisted-pair with the shield). The maximum length can change depending on the diameter and others cable components. Below we show four cable types, but there are more options. No special cable type is required. Usually the cables that connect the instruments can be used for the trunk line. The network cable for Profibus PA and Foundation Fieldbus are produced by several manufacturers becoming easy the choice. Cable Type A Cable options Pair Diameter Max. length (m) Type single 0.75mm2 1900 A mult 0.32mm2 1200 B mult 0.13mm2 400 C mult 1.25mm2 200 D - Zo @ 31,25KHz = 100 Ohm ± 20% Max. Attenuation @ 39KHz = 3dB/ Km Max.capacitance unbalance to earth = 2 nF/ Km Max. DC resistance per conductor = 22 Ω/ Km Max. propagation delay change 7.8 - 39KHz = 1.7 µs/ Km 2 Conductor transversal area: 0.75mm . Note: only the shield must be grounded, never the communication wires. If the cable has no shielding wire, it should be inside a metal conduit that works as a shield. Spurs A spur is a branch off the trunk and can vary in length between 1 and 120m. Spurs length is basically independent of the cable type and the total length can´t not exceeded the specifications, but depends on the amount of equipment connected in it. Never connect more than four devices on the spurs. The spurs are used to connect the equipments to the trunk so they can be removed without interrupting the network operation. Equipment x Spur length The maximum segment length is the sum of the trunks and spurs lengths and the lengths less than 1 m are not considered spurs. The amount of spurs and the number of equipment should be in accordance with the table below. Number of Spurs 1 equipment amount of the equipments 2 3 equipments equipments 4 equipaments 25 - 32 1m 1m 1m 1m 19 - 24 30 m 1m 1m 1m 15 - 18 60 m 30 m 1m 1m 13 - 14 90 m 60 m 30 m 1m 1 - 12 120 m 90 m 60 m 30 m Terminador The terminator is designed to match the network impedance and for this must be installed on all edges of trunk line, so the reflection effect will be eliminated and the network works normally. Note 1: For Ex installations you should not exceed the 9 equipments in group IIC and the length should be up to 30m with one equipment per spur and the consumption less than 110 mA. Note 2: It is important to pay attention to the spur length when using the star topology, since the Spurs in this case are often longer when compared with the bus line topology. 4 Sense MD - Passive Junction Box - General Purpose Provide a simple and secure way the distribution of the points for the network of up to four equipments. The case is plastic material and has internal terminal for connecting the spurs allowing the field installation with protection against liquid penetration (IP66). The input and output network is connected in a dual plug-in connector, allowing the distributor board disconnection without interrupting the rest of the network, being de-energized only their spurs. Junction box for general purpose 2 or 4 points available Network Passive junction box only for spurs of the network trunk line Points General Purpose 2 PA-MD-2D 4 PA-MD-4D 2 FF-MD-2D 4 FF-MD-4D Profibus PA General purpose module, plastic house Internal network terminator Foundation Fieldbus Mechanical Dimensions Module internal view FD - Passive Junction Box - General Purpose Note: also available for connector version Provide a simple and secure way the distribution points for a network of up to eight equipments. The case is in plastic or metal material with terminals for spur connections allowing the field installation with protection against liquid penetration (IP66). The input and output network connector is a dual plug-in, allowing the distributor board disconnection without interrupting the rest of the network, being de-energized only their spurs. 4, 6 or 8 points available General purpose in plastic or metallic case Module internal view Passive junction box only for spurs. Sense Junction box for general purpose Network Plastic Profibus PA Metallic Foundation Fieldbus Plastic Metallic general purpose general purpose FD4 FD6 FD8 PA-FD-4D PA-FD-6D PA-FD-8D PA-FDM-4D PA-FDM-6D PA-FDM-8D FF-FD-4D FF-FD-6D FF-FD-8D FF-FDM-4D FF-FDM-6D FF-FDM-8D 5 Specifications PROFIBUS PA Plastic Features Metallic FOUNDATION FIELDBUS Plastic Metallic 2 points MD model PA-MD-2D FF-MD-2D 4 points MD model PA-MD-4D FF-MD-4D 4 points FD model PA-FD-4D PA-FDM-4D FF-FD-4D FF-FDM-4D 6 points FD model PA-FD-6D PA-FDM-6D FF-FD-6D FF-FDM-6D 8 points FD model PA-FD-8D PA-FDM-8D FF-FD-8D FF-FDM-8D Signaling power no no Short electronic protection for spurs no no Terminator yes yes Terminator signaling no no Ex protection - - Fault monitoring - - Network connection 3 ways double plug-in terminal 2.5 mm² 3 ways double plug-in terminal 2.5 mm² Cable type Profibus PA cable Foundation Fieldbus cable Input/Output for trunk cable cable gland PG16 cable gland PG16 Cable disconnection allowed without interrupting the rest of the network allowed without interrupting the rest of the network Number of spurs 2, 4, 6 or 8 2, 4, 6 or 8 Spur connections 3 ways plug-in terminal 2.5 mm² 3 ways plug-in terminal 2.5 mm² Housing material Plastic (MD and FD) aluminum (FDM) Plastic (MD and FD) aluminum (FDM) Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket Protection class IP 66 IP 66 Operation temperature -20°C to +55°C -20°C to +55°C Weight Approx. 1600g Approx. 1600g Accessories included terminal, isolator tube, cover, cable gland terminal, isolator tube, cover, cable gland Mechanical Dimensions Topology PLC Dimensions - FD FD A (mm) B (mm) C (mm) Plastic 200 120 57,5 Metallic 200 120 65 Segment Protector General Purpose C Segment Protector General Purpose Fieldbus or Profibus PA A * Dimensions for 4, 6 and 8 points models. 6 B 8 points Sense MD - Segment Protector - General Purpose Segment Protectors are fieldbus distributor which incorporate electronic protection against short-circuit for each network segment and its spurs. They are available with 2 or 4 points of derivations and mounted in plastic box. All versions are mounted with cable gland and double plug-in connector for the trunk line connection and plug-in connectors for the derivations (Spurs). Electronic Protection and Network terminator The network modules for Profibus PA and Foundation Fieldbus have electronic protection against short circuit in each spur. FF and PA modules also incorporate the network terminator and to enable it turn on a dipswitch located inside the module. 4 or 6 points available general purpose in plastic house Protection against short-circuit Network terminator inside the module Segment Protector for general purpose Network Points General Purpose 2 PA-MD-2P 4 PA-MD-4P 2 FF-MD-2P 4 FF-MD-4P Profibus PA Foundation Fieldbus Mechanical Dimensions Module internal view FD - Segment Protector - general purpose Segment Protectors are fieldbus distributor which incorporate electronic Note: also available for connector version protection against short-circuit and overload for each spur. They are available with 4, 6 or 8 derivation points and can be mounted in plastic or metal box.They have double plug-in connector for trunk line connection and plug-in connectors for the derivations (Spurs). All versions are mounted with cable glands. Electronic Protection and Network terminator Module internal view The network modules for Profibus PA and Foundation Fieldbus have Electronic Protection against short-circuit in each spurs. FF and PA modules also incorporate the network terminator for switching it only turn on the dipswitch located inside the module. Sense Segment Protector general purpose Rede Plastic Profibus PA Metallic Foundation Fieldbus Plastic Metallic general purpose general purpose FD4 FD6 FD8 PA-FD-4P PA-FD-6P PA-FD-8P PA-FDM-4P PA-FDM-6P PA-FDM-8P FF-FD-4P FF-FD-6P FF-FD-8P FF-FDM-4P FF-FDM-6P FF-FDM-8P 7 Specifications Features PROFIBUS PA FOUNDATION FIELDBUS House Plastic MD 2 points model PA-MD-2P FF-MD-2P MD 4 points model PA-MD-4P FF-MD-4P FD 4 points model PA-FD-4P PA-FDM-4P FF-FDM-4P FF-FDM-4P FD 6 points model PA-FD-6P PA-FDM-6P FF-FDM-6P FF-FDM-6P FD 8 points model PA-FD-8P PA-FDM-8P FF-FDM-8P FF-FDM-8P Power supply 9 to 32 Vdc 9 to 32 Vdc Current per channel 40 mA ± 5% 40 mA ± 5% Internal signaling red led red led Electronic Protection for short-circuit in spurs yes yes Terminator yes yes Terminator signaling no no Ex protection - - Consumption without load fieldbus distributor: 2points: < 12mA / 4 points: < 18mA / 6 points: < 25mA / 8 points: < 38mA Metallic Fault monitoring Plastic Metallic Red Led blinking : short-circuit in the spurs Network connection double 3 ways plug-in terminal 2.5 mm² double 3 ways plug-in terminal 2.5 mm² Cable type Profibus PA cable Foundation Fieldbus cable Input/Output for trunk cable cable gland PG16 cable gland PG16 cable desconnexion allowed without interrupting the rest of the network allowed without interrupting the rest of the network Number of spurs 2, 4, 6 or 8 2, 4, 6 or 8 Spur connections 3 ways plug-in terminal 2.5 mm² 3 ways plug-in terminal 2.5 mm² Housing material Plastic (MD e FD) aluminum (FDM) Plastic (MD e FD) aluminum (FDM) Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket Protection class IP 66 IP 66 Operation temperature -20°C to +55°C -20°C to +55°C Weight Aprox. 1600g Aprox. 1600g Accessories included terminal, isolator tube, cover, cable gland terminal, isolator tube, cover, cable gland Mechanical Dimensions Topology PLC Tabela de Dimensões - FD FD A (mm) B (mm) C (mm) Plastic 200 120 57.5 Protetor de Segmento Uso Geral 25 Protetor de Segmento Uso Geral Fieldbus ou C Profibus PA A B Metallic 200 120 65 * Dimensions for 4 and 6 points models. 8 Protector 8 points Sense MD - Segment Protector Increased Safety Ex e Segment Protectors are fieldbus distributors which incorporate electronic protection against short-circuit for each network segment and its spurs. They are available with 2 or 4 points of derivations and are mounted in a plastic box. All versions are mounted with cable glands, double plug-in connector for trunk line connection and plug-in connectors for the derivations (Spurs). Electronic Protection and Network terminator Segment Protector Ex e The network modules for Profibus PA and Foundation Fieldbus have Electronic Protection against short-circuit in each spurs. FF and PA modules also incorporate the network terminator for switching it only turn on the dip switch located inside the module. 4 or 6 points available Ex e model in plastic house Short-circuit protection Switchable integrated Network terminator Network Points General Purpose 2 PA-MD-2P-Exe 4 PA-MD-4P-Exe 2 FF-MD-2P-Exe 4 FF-MD-4P-Exe Profibus PA Foundation Fieldbus Mechanical Dimensions Module internal view 4 3 2 1 FD - Segment Protector Increased Safety Ex e Note: also available for connector version Segment Protectors are fieldbus distributors which incorporate electronic protection against short-circuit for each network segment and its spurs. They are available with 4, 6 or 8 derivation points and can be mounted in a plastic or metal box. All models are mounted with cable glands, double plug-in connector for the trunk line cable and plug-in connectors for the derivations (Spurs). Electronic Protection and Network terminator Module internal view The network modules for Profibus PA and Foundation Fieldbus have Electronic Protection against short-circuit in the spurs. FF and PA modules also incorporate the network terminator for switching it turns on the dip switch located inside the module. Sense Segment Protector Ex e Network Plastic Profibus PA FD6 FD8 PA-FD-4P-Exe PA-FD-6P-Exe PA-FD-8P-Exe PA-FDM-4P-Exe PA-FDM-6P-Exe PA-FDM-8P-Exe FF-FD-4P-Exe FF-FD-6P-Exe FF-FD-8P-Exe FF-FDM-4P-Exe FF-FDM-6P-Exe FF-FDM-8P-Exe Ex e Metallic Foundation Fieldbus FD4 Plastic Ex e Metallic 9 Specifications PROFIBUS PA Plastic Metallic FOUNDATION FIELDBUS Plastic Metallic MD 2 points model PA-MD-2P-Exe - FF-MD-2P-Exe - MD 4 points model PA-MD-4P-Exe - FF-MD-4P-Exe - FD 4 points model PA-FD-4P-Exe PA-FDM-4P-Exe FF-FD-4P-Exe FF-FDM-4P-Exe FD 6 points model PA-FD-6P-Exe PA-FDM-6P-Exe FF-FD-6P-Exe FF-FDM-6P-Exe FD 8 points model PA-FD-8P-Exe PA-FDM-8P-Exe FF-FD-8P-Exe FF-FDM-8P-Exe Power supply 9 to 32 Vdc 9 to 32 Vdc Current per channel 40 mA ± 5% 40 mA ± 5% Internal indicator red led red led Short Electronic Protection in the spurs yes yes Terminator yes yes Terminator signaling não não Ex protection Ex e Ex e Consumption without load fieldbus distributor 2 points: < 12mA / 4 points: < 18mA / 6 points: < 25mA / 8 points: < 38mA Fault monitoring Red led blinking: short-circuit in the spurs Network connection double 3 ways plug-in terminal 2.5 mm² double 3 ways plug-in terminal 2.5 mm² Cable type Profibus PA cable Foundation Fieldbus cable Input/Output for trunk cable cable gland PG16 cable gland PG16 Cable desconnexion allowed without interrupting the rest of the network allowed without interrupting the rest of the network Number of spurs 2, 4, 6 or 8 2, 4, 6 or 8 Spur connections 3 ways plug-in terminal 2.5 mm² 3 ways plug-in terminal 2.5 mm² Housing material Plastic (MD e FD) aluminum (FD) Plastic (MD e FD) aluminum (FD) Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket Protection class IP 66 IP 66 Operation temperature -20°C to +55°C -20°C to +55°C Weight Aprox. 1600g Aprox. 1600g Accessories included terminal, isolator tube, cover, cable gland terminal, isolator tube, cover, cable gland Mechanical Dimensions Topology PLC Tabela de Dimensões - FD FD A (mm) B (mm) C (mm) Plastic 200 120 91 Metallic 200 120 65 Segment Protector Ex e C Segment Protector Ex e Fieldbus or Profibus PA A * Dimensions for 4 and 6 points models. 10 B Protector 8 points Sense MD - Passive Derivator Ex i Provide in a simple and secure way the network equipment connection of up to four points using a plastic box with internal terminal connections to spurs that allows the installation in field with protection against liquid penetration (IP66). The input and output connector of the trunk line is a double plug-in connector allowing the distributor board disconnection without interrupting the rest of the network, being de-energized only their spurs. Intrinsic safety modules 4 or 6 points available Network Derivators for hazardous areas Intrinsic safety modules in plastic house Spur points Modules Ex i 2 PA-MD-2D-Exi 4 PA-MD-4D-Exi 2 FF-MD-2D-Exi 4 FF-MD-4D-Exi Profibus PA Internal network terminator Foundation Fieldbus Mechanical Dimensions Module internal view 57,5 24 16 26 0 80 FD - Passive Derivators Ex i Note: also available for connector version Provide in a simply and secure way the network equipment connection of up to eight equipments, using a plastic or metallic box with internal connection terminals to spurs allowing the installation in field with protection against liquid penetration (IP66). The input and output connector of the trunk line is a double plug-in connector allowing the distributor board disconnection without interrupting the rest of the Network being only their spurs de-energized. 4, 6 or 8 points available Intrinsic safety module in plastic or metallic house Module internal view Passive derivators only for spurs. Sense Intrinsic safety modules Network Plastic Profibus PA FD6 FD8 PA-FD-4D-Exi PA-FD-6D-Exi PA-FD-8D-Exi PA-FDM-4D-Exi PA-FDM-6D-Exi PA-FDM-8D-Exi FF-FD-4D-Exi FF-FD-6D-Exi FF-FD-8D-Exi FF-FDM-4D-Exi FF-FDM-6D-Exi FF-FDM-8D-Exi Ex i Metallic Foundation Fieldbus FD4 Plastic Ex i Metallic 11 Specifications PROFIBUS PA Plastic Metallic FOUNDATION FIELDBUS Plastic Metallic Modelos MD 2 points PA-MD-2D-Exi - FF-MD-2D-Exi - Modelos MD 4 points PA-MD-4D-Exi - FF-MD-4D-Exi - FD 4 points model PA-FDM-4D-Exi PA-FDM-4D-Exi FF-FD-4D-Exi FF-FDM-4D-Exi FD 6 points model PA-FDM-6D-Exi PA-FDM-6D-Exi FF-FD-6D-Exi FF-FDM-6D-Exi FD 8 points model PA-FDM-8D-Exi PA-FDM-8D-Exi FF-FD-8D-Exi FF-FDM-8D-Exi Function junction box for network junction box for network Power supply indicator no no Short Electronic Protection in the spurs no no Terminator yes yes Terminator signaling no no Ex protection Ex i Ex i Fault monitoring - - Network connection 3 ways double plug-in terminal 2.5 mm² 3 ways double plug-in terminal 2.5 mm² Cable type PA cable Fieldbus cable Input/Output for trunk cable cable gland PG16 cable gland PG16 cable desconnexion allowed without interrupting the rest of the network allowed without interrupting the rest of the network Number of spurs 2, 4, 6 or 8 2, 4, 6 or 8 Spur connections 3 ways plug-in terminal 2.5 mm² 3 ways plug-in terminal 2.5 mm² Housing material Plastic (MD e FD) aluminum (FD) Plastic (MD e FD) aluminum (FD) Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket Protection class IP 66 IP 66 Operation temperature -20°C to +55°C -20°C to +55°C Weight Aprox. 1600g Aprox. 1600g Accessories included terminal, isolator tube, cover, cable gland terminal, isolator tube, cover, cable gland Mechanical Dimensions Topology SDCD Tabela de Dimensões - FD 25 FD A (mm) B (mm) C (mm) Exi Barrier Ex i Derivator C Ex i Derivator Fieldbus or Profibus PA Ex i A Plastic 200 120 91 Metallic 200 120 65 * dimension for 4 and 6 points models. 12 B Ex i Ex i Ex i 8 points Ex i field equipments Ex i field equipments Sense Field Barrier Exi It´s a fieldbus distributor that integrates an intrinsic safety barrier for each individual output (Spur), providing the signaling and communication signal to each field instrument connected in the spur. Manufactured with high technology the field barrier allows the equipments disconnection in the spurs with the bus line energized. Available for Profibus PA and Foundation Fieldbus the barrier incorporates an intrinsical safe protection to each individual spur available in 2, 4, 6 or 8 points of derivations. Total Security Módulos MD The power sent to the field instrument is limited by the intrinsic safety barrier that provides a smart protection against short-circuit that turns off the output when the fault is detected and maintained the spur output current to a minimum value no contributing to the communication collapse in the trunk line due to the high current consumption. I (mA) Features I (mA) 40 40 12 12 7 7 Módulos FD Connectivity with safety and practicality Available in Plastic or Metallic material with 2, 4, 6 or 8 points One barrier required for each derivation point (spur). Modules certified for intrinsic safety Short-Circuit Short-Circuit t (s) Sense field barrier * Device t (s) Product offer in the market connected to spur with 12mA current consumption Intrinsic Safety Definitions Used in explosive atmospheres, zones 1 and 2 Fieldbus distributors spurs) in all models (network and The intrinsic safety definition is a representative prevention concept of the ignition by power limiting of the incoming bus supply as well as installation components in the field. The working principle is based on manipulating and storing electric low-power incapable of producing a detonation of the explosive atmosphere due to heating effects or electrical sparks. In general it can be applied to several equipments and instrumentation systems, and the electric power only can be controlled at low levels in instruments such as electronic current transmitters, pneumatic converters, limit switches, signaling, etc. The basic principle of the intrinsic safety is handle and storage low energy, so the circuit installed in the safe area never has enough energy rated (manipulated or stored) capable of causing ignition in the potentially explosive atmosphere. The great advantage of intrinsic safety is to allow the instruments disconnection even energized. Topology in Safe Network (Ex i) PLC Barrier Ex i Trunk line Ex e Barrier Ex i Fieldbus or Profibus PA Ex i Intrinsic Safety Spurs( Ex i) Ex i Ex i Field Instruments Ex i Sense Ex i Field Instruments Ex i 13 MD - Field Barrier Exi The MD field barrier is fieldbus distributor which incorporates an intrinsic safety barrier for each spur. It´s available with 2 points of derivation in a plastic house. The input and output connector of the line trunk is a double plug-in terminal block, allowing the distributor board disconnection without interrupting the rest of the network being only their spurs de-energized (spurs). Module internal view Intrinsic Safety Barrier Terminator Modelo Profibus PA PA-MD-2B-Exei Foundation Fieldbus FF-MD-2B-Exei Mechanical Dimensions 2 24 OUT 60 networl plug-in terminal spur plug-in terminal Network IN 1 Allow the exchange of field equipment with the network working. 26 16 0 82 Specifications PROFIBUS PA FOUNDATION FIELDBUS Function Intrinsic Safety Intrinsic Safety Operating voltage 16 to 35 Vcc 16 to 35 Vcc Consumption without load 16V - < 37mA / 35V - < 30mA 16V - < 37mA / 35V - < 30mA Protection reverse polarity and short-circuit I < 20mA reverse polarity and short-circuit I < 20mA Voltage output 13,6V / 1% - without load, 13.4 to 13.8 and<10V to 40mA 13,6V / 1% - without load, 13.4 to 13.8 and<10V to 40mA Max. current per output 40mA Led signaling Electronic Protection nos seg. 40mA led verde: Power supply / vermelho piscando: curto-circuito na saída yes Fault monitoring yes Red led blinking: short-circuit in the spurs Ex protection Ex i (a barrier for each segment) Ex i (a barrier for each segment) Terminator yes yes Terminating indicator no no Network connection 3 ways double plug-in terminal 3 ways double plug-in terminal Cable type Profibus PA cable Foundation Fieldbus cable Input/Output of the main cable by cable gland PG16 by cable gland PG16 cable disconnection allowed without interrupting the rest of the network allowed without interrupting the rest of the network Number of the spurs 2 points 2 points Spur connections bornes plug-in 3 vias bornes plug-in 3 vias Housing material Plastic Plastic Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket Protection class IP 66 IP 66 Operation temperature -20ºC to +55ºC -20ºC to +55ºC Accessories included terminals, isolator tube, cover, cable gland terminals, isolator tube, cover, cable gland 14 Sense FD - Field Barriers Exi Module FD4 Module FD6 Module FD8 The FD Field Barrier is a Fieldbus distribution module that integrates an intrinsic safety barrier for each spur. It´s available with 4, 6 or 8 points for the spurs in a plastic or metallic box. The input and output network (trunk) is connected in a double plug-in connector that allows the distributor board disconnection without interrupting the rest of the network, and being turns off only in their derivations (spurs). Network FD4B FD6B FD8B Plastic Ex i PA-FD-4B-Exei PA-FD-6B-Exei PA-FD-8B-Exei Metallic Ex i PA-FDM-4B-Exei PA-FDM-6B-Exei PA-FDM-8B-Exei Plastic Ex i FF-FD-4B-Exei FF-FD-6B-Exei FF-FD-8B-Exei Metallic Ex i FF-FDM-4B-Exei FF-FDM-6B-Exei FF-FDM-8B-Exei Profibus PA Fieldbus Module internal view Terminator Sense Protection of the network terminal in Increased Safety Ground terminal Network plug-in terminal Spur Status Led (blink in short-circuit) Pression terminal for the Spurs Allow the exchange of field equipment with the network energized. Spur Status Led (blink in short-circuit) 15 Specifications Features PROFIBUS PA FOUNDATION FIELDBUS Modelo 4 points PA-FDM-4B-Exei FF-FDM-4B-Exei Modelo 6 points PA-FDM-6B-Exei FF-FDM-6B-Exei Modelo 8 points PA-FDM-8B-Exei FF-FDM-8B-Exei Function Intrinsic Safety Intrinsic Safety Operating voltage 16 to 35 Vcc 16 to 35 Vcc Consumption without load 16V - < 37mA / 35V - < 30mA 16V - < 37mA / 35V - < 30mA Protection reverse polarity and short-circuit I < 20mA reverse polarity and short-circuit I < 20mA Output voltage 13,6V / 1% - without load, 13.4V to 13.8 and >10 to 40mA 13,6V / 1% - without load, 13.4V to 13.8 and >10 to 40mA Max. channel output current 40mA 40mA Led indication Green Led: Power Supply / red blinking: output short-circuited Short-circuit electronic protection in the segments yes yes Terminator yes yes Termination resistor indicator no no Fault monitoring Red led blinking: short-circuit in the spurs Ex protection Ex i (a barrier for each segment) Ex i (a barrier for each segment) Network connection 3 ways double plug-in terminal 2.5 mm² 3 ways double plug-in terminal 2.5 mm² Cable type Profibus PA cable Foundation Fieldbus cable Input/Output for trunk cable cable gland PG16 cable gland PG16 cable disconnection allowed without interrupting the rest of the network allowed without interrupting the rest of the network Number of spurs 4, 6 or 8 4, 6 or 8 Spur connections 3 ways pression terminals 2.5 mm² 3 ways pression terminals 2.5 mm² Housing material aluminum aluminum Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket Protection class IP 66 IP 66 Operation temperature -20°C to +55°C -20°C to +55°C Weight Aprox. 1600g Aprox. 1600g Accessories included terminal, isolator tube, cover, cable gland terminal, isolator tube, cover, cable gland Mechanical Dimensions Dimension table A (mm) B (mm) C (mm) Plastic Ex i 220 120 91 Metallic Ex i 200 FD C C A B 120 A B A B 65 Barrier 4 points 16 C Barrier 6 points Barrier 8 points Sense FD - Field Barrier Exi with Connector Network Plastic PA FF Metallic 7/8" connector model FD4B FD6B PA-FD-4B-VM-Exei PA-FD-6B-VM-Exei PA-FDM-4B-VM-Exei PA-FDM-6B-VM-Exei Module FD8-VM Module FD8-V1 Module FD4-V1 Module FD6-V1 Module FD4-VM Module FD6-VM The FD Field Barrier is a fieldbus distributin module that integrates a intrinsic safety barrier for each spur. It´s available with 4, 6 or 8 points for spurs with 7 / 8 “or M12 connectors in plastic or Metal box. FD8B Network PA-FD-8B-VM-Exei PA-FDM-8B-VM-Exei Plastic FF-FD-4B-VM-Exei FF-FD-6B-VM-Exei FF-FD-8B-VM-Exei Metallic FF-FDM-4B-VM-Exei FF-FDM-6B-VM-Exei FF-FDM-8B-VM-Exei PA FF M12 connector model FD4B FD6B Plastic PA-FD-4B-V1-Exei PA-FD-6B-V1-Exei PA-FD-8B-V1-Exei Metallic PA-FDM-4B-V1-Exei PA-FDM-6B-V1-Exei PA-FDM-8B-V1-Exei Plastic FF-FD-4B-V1-Exei FF-FD-6B-V1-Exei FF-FD-8B-V1-Exei Metallic FF-FDM-4B-V1-Exei FF-FDM-6B-V1-Exei FF-FDM-8B-V1-Exei Module internal view 7/8” network connector FD8B Protection to the network terminals in Increased Safety Terminator Ground terminal Networ plug-in terminal 7/8” Spur connector Pression terminal Spur Status Led (blink for short-circuit) Sense 17 Specifications Features PROFIBUS PA FOUNDATION FIELDBUS Modelo 4 points PA-FDM-4B-VM-Exei FF-FDM-4B-VM-Exei Modelo 6 points PA-FDM-6B-VM-Exei FF-FDM-6B-VM-Exei Modelo 8 points PA-FDM-8B-VM-Exei FF-FDM-8B-VM-Exei Function Intrinsic Safety barrier Intrinsic Safety barrier Operating voltage 16 to 35 Vdc 16 to 35 Vdc Consumption without load 16V - < 37mA / 35V - < 30mA 16V - < 37mA / 35V - < 30mA Protection reverse polarity and short-circuit I < 20mA reverse polarity and short-circuit I < 20mA Output voltage 13,6V / 1% - without load, 13,4V to 13,8V and >10 to 40mA 13,6V / 1% - without load, 13,4V to 13,8V and >10 to 40mA Max. channel output current Led indication Green Led: power supply / red blinking: output short-circuited Short-circuit electronic protection in the segments yes yes Terminator yes yes Terminating resistor indicator no no Fault monitoring Red led blinking: short-circuit in the spurs Ex protection Ex i (a barrier for each segment) Ex i (a barrier for each segment) Network connection 3 ways double plug-in terminal 2.5 mm² 3 ways double plug-in terminal 2.5 mm² Cable type Profibus PA cable Foundation Fieldbus cable Input/Output for trunk cable via 7/8" connector via 7/8" connector cable disconnection allowed without interrupting the rest of the network allowed without interrupting the rest of the network Number of spurs 4, 6 or 8 4, 6 or 8 Spur connections via 7/8" connector via 7/8" connector Housing material aluminum aluminum Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket Protection class IP 66 IP 66 Operation temperature -20°C to +55°C -20°C to +55°C Weight Approx. 1600g Approx. 1600g Accessories included kit terminal,tubo isolador, tampão kit terminal, tubo isolador, tampão 2 4 Macho 7/8” Dimension table FD Plastic Ex i Metallic Ex i A (mm) 220 B (mm) 120 C (mm) 120 4 2 Fêmea 7/8” C 3 1 4 2 Fêmea 7/8” Foundation Fieldbus Pino 1 = Bus Pino 2 = Bus + Pino 3 = S (dreno) Pino 4 = Not Used Spur Rede OUT Rede IN 1 3 2 4 3 1 4 2 3 1 4 2 91 65 * Dimensions for 4 and 6 points models. 18 1 Profibus PA Pino 1 = Bus + Pino 2 = Not Used Pino 3 = Bus Pino 4 = S (dreno) 18 A 200 3 Macho 7/8” Fêmea 7/8” Fêmea M12 B Barrier 8 points Profibus PA Pino 1 = Bus + Pino 2 = Not Used Pino 3 = Bus Pino 4 = S (dreno) Barrier VM 3 Foundation Fieldbus Pino 1 = Bus Pino 2 = Bus + Pino 3 = S (dreno) Pino 4 = Not Used Barrier V1 Mechanical Dimensions Spur Rede OUT Rede IN 1 Sense Code Key - Terminal V1 - M12 Connector VM - 7/8" Connector MD - 2 or 4 points FD - 4, 6 or 8 points 2 - 2 points 4- 4 points 6 - 6 points 8 - 8 points Housing Connetion Spurs PA - FD M - 8 B - VM - : Plastic M : Metal D- Passive Derivador Derivator Passivo P - Segment Protector Protector de SegmentoIntrinsic B - Intrinsic Safety Safety Barrier Network Type Tipo Ex - general purpose Ex - For Potentially Explosive Atmosphere e - Increased Safety i - Intrinsic Safety Material PA - Profibus PA FF - Foundation Fieldbus - Version Available: general purpose PG Exi 11 PG 11 PG Exe 11 Cable Gland (PG16 available) Ex e Ex i TP-Ex e - 11 Covers ( PG16 available) 7/8" male Sense Conector Conector Connector Connectors 7/8" Female M12 Male 19 www.sense.com.br Contact us: HEADQUARTERS Rua Tuiuti, 1237 - Tatuapé São Paulo - SP - Cep: 03081-000 Fone: 55 11 6190-0444 Fax:(11) 6190-0404 [email protected] FACILITY Av. Joaquim Moreira Carneiro. 600 - Santana Santa Rita do Sapucaí - Minas Gerais - Cep: 37540-000 Fone: 55 35 3471-2555 Fax: 55 35 3471-2033 Sensors and Instruments 20 20000000049 Rev.1 - 03/09 - All information above may be modified with no previous notice.. Sense