GALLERIA AT HOUSTON
HOUSTON, TX
GENERAL CONTRACTOR NOTES
1. BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY:
A. THE GC SHALL CONTACT THE NEXTORE P.M. OR THE PERMIT EXPEDITOR TO SECURE THE PERMIT. PERMIT SHALL BE MOUNTED IN A
VISIBLE LOCATION AT THE SITE. PERMITS SHALL BE PAID FOR BY THE GC AND SUBMITTED TO TENANT AS A NET COST.
B. THE GC SHALL ARRANGE FOR ALL REQUIRED INSPECTIONS.
C. THE GC SHALL DETERMINE IF THE INSPECTORS WILL BE CHECKING LAB / LENS PROCESSING ROOM EQUIPMENT FOR UL OR ETL LABELS
AND NOTIFY THE CONSTRUCTION MANAGEMENT TEAM NO LATER THAN 4 WEEKS BEFORE "PUNCH".
D. IF REQUIRED, A "TEMPORARY C OF O" OR BUILDING DEPARTMENT APPROVAL SHALL BE RECEIVED TO SET DOWN EQUIPMENT.
A.
'DOCUMENTS', AS USED HEREIN, SHALL COMPRISE THE ENTIRE INTEGRATED SET OF ALL WRITTEN INSTRUMENTS RELATED TO THE PROJECT, INCLUSIVE OF, BUT NOT
EXCLUSIVE TO, ALL CONTRACTS, SUBCONTRACTS, DRAWINGS, SKETCHES, MEMORANDA, ADDENDA, SPECIFICATIONS, MANUALS, POLICIES, RULES AND REGULATIONS,
LANDLORD DESIGN CRITERIA, SUBMITTALS, SHOP DRAWINGS, PERMITS, APPROVALS, REGULATIONS AND CODES. 'PROJECT', AS USED HEREIN, SHALL REFER TO THE ENTIRE
SCOPE OF PROVIDING A FINISHED FACILITY, READY AND USEABLE FOR ITS INTENDED PURPOSE. GC SHALL BE RESPONSIBLE TO VISIT THE SITE PRIOR TO SUBMISSION OF BID.
ANY DISCREPENCIES FROM PLANS SHALL BE CONVEYED TO THE NEXTORE PROJECT MANAGER PRIOR TO BID SUBMISSION. SUBMISSION OF BID SHALL CONSTITUTE
ACKNOWLEDGEMENT AND ACCEPTANCE OF EXISTING CONDITIONS.
B.
ALL MATERIALS AND/OR LABOR FOR THE PROJECT WHICH IS SHOWN ON THE DRAWINGS AND SPECIFICATIONS OR IS REASONABLY INFERABLE THEREIN AS BEING
NECESSARY TO PRODUCE A FINISHED PROJECT, SHALL BE PROVIDED BY GENERAL CONTRACTOR, WHETHER OR NOT THE WORK IS EXPRESSLY COVERED IN THE DOCUMENTS.
THIS APPLIES TO ALL WORK, WITH THE EXCEPTION OF THOSE ITEMS INDICATED N.I.C. ("NOT IN CONTRACT") OR BY OTHERS. THE DESIGN INTENT OF THE DRAWINGS SHALL
ALWAYS BE THE GOAL.
2. DIMENSIONS:
THE WORD 'HOLD' REFERS TO A CRITICAL DIMENSION AND MUST BE ADHERED TO. IF THESE DIMENSIONS CAN NOT BE MET, CALL THE
NEXTORE P.M. FOR DIRECTION.
C.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COORDINATION BETWEEN SUBCONTRACTORS, SUPPLIERS, VENDORS OR ANY OTHER PARTIES SUPPLYING
GOODS OR SERVICES TO THE PROJECT. NO EXTRA COMPENSATION WILL BE GIVEN TO ANY PARTY WHO HAS BID FROM AN INCOMPLETE SET OF DOCUMENTS OR WITH
INSUFFICIENT FAMILIARITY WITH THE PROJECT OR THE SPECIFIC REQUIREMENTS THEREOF. IN THE EVENT OF INCONSISTENCIES OR DISCREPANCIES BETWEEN THE
DOCUMENTS, CODES, CRITERIA OR REQUIREMENTS, THE MOST STRINGENT SHALL APPLY. THE GENERAL CONTRACTOR SHALL NOTIFY THE NEXTORE PROJECT MANAGER
IMMEDIATELY OF SUCH DISCREPANCIES OR INCONSISTENCIES.
3. ON-SITE COMMUNICATION:
A. THE GC SHALL CONTACT THE NEXTORE P.M. TO RESOLVE ALL FIELD ISSUES.
B. GC TO HAVE CELL PHONE WITH VOICEMAIL CAPABILITIES.
C. GC TO HAVE LAPTOP ON SITE WITH WIFI CAPABILITIES.
D.
IT IS THE RESPONSIBILITY OF THE G.C. TO VERIFY BOTH EXISTING SITE CONDITIONS AND DIMENSIONS WITHIN 24 HOURS OF STARTING ANY PROJECT. THE G.C. SHALL
NOTIFY THE CONSTRUCTION MANAGER IMMEDIATELY OF ANY DISCREPANCIES PRIOR TO INITIATING CONSTRUCTION.
4. CHANGE ORDERS:
NO ADDITIONAL COSTS OR DESIGN CHANGES WILL BE ACCEPTED WITHOUT THE WRITTEN APPROVAL OF THE NEXTORE P.M. AND THE
EXECUTION OF THE NEXTORE CHANGE ORDER PROCEDURE, PRIOR TO THE COMMENCEMENT OF SUCH WORK. CHANGE ORDER WORK
COMPLETED WITHOUT SIGNED APPROVAL TO DO SAME, IS DONE SO AT THE GC'S RISK.
E.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING A CURRENT SET OF CONSTRUCTION DRAWINGS ON SITE AT ALL TIMES DURING
CONSTRUCTION. THE GENERAL CONTRACTOR SHALL INDICATE ON THESE PLANS ALL APPROVED CHANGES TO THE WORK. THIS SET OF DRAWINGS SHALL BE UPLOADED VIA
EVOCO IN PDF FORMAT TO THE NEXTORE PROJECT MANAGER UPON COMPLETION OF THE PROJECT. THESE DRAWINGS SHALL BE MARKED UP TO REPRESENT A COMPLETE
AND ACCURATE SET OF “AS-BUILT” DRAWINGS. ANY AND ALL CHANGES SHALL BE NOTED ON SAID PLANS.
F.
IF ANY ERRORS, DISCREPANCIES OR OMISSIONS APPEAR OR ARE EVIDENT ON ANY OF THE DOCUMENTS, THE GENERAL CONTRACTOR, SUBCONTRACTOR, VENDOR OR
SUPPLIER SHALL IMMEDIATELY NOTIFY THE NEXTORE PROJECT MANAGER.
G.
5. SUBCONTRACTOR COORDINATION:
THE GC MUST BE PRESENT AT ALL TIMES FOR THE DURATION OF CONSTRUCTION. THE GC SHALL GIVE SUBCONTRACTORS APPROPRIATE
NOTICE BEFORE REQUIRING THEM ON SITE, COORDINATE INSTALLATION DATES, AND COMMUNICATE SITE SPECIFIC DETAILS. THE GC
SHALL COORDINATE THE INSTALLATION SCHEDULE AND DIVISION OF WORK WITH THE NEXTORE P.M. SUBCONTRACTORS SHOULD
CONTACT THE GC FOR SCHEDULE CLARIFICATIONS.
MILLWORK / CASEWORK: GC SHALL COORDINATE CRITICAL DIMENSIONS PRIOR TO WALL CONSTRUCTION AND HAVE THE AREA READY
PRIOR TO FIXTURE DELIVERY. READY SHALL BE DEFINED AS FLOORING DOWN THRU-OUT THE RETAIL AND OPTOMETRIC DOCTOR (OD)
RECEPTION, LIGHTING SOFFITS BUILT OUT, DRYWALLED, FINISHED, PAINTED AND LIGHTING FIXTURES INSTALLED, ALL WALLS IN THE
RETAIL AND OD RECEPTION MUST BE FINISHED AND PAINTED, ALL ELECTRICAL AND MECHANICAL ROUGH-OUTS MUST BE COMPLETED,
STORE MUST BE SECURED FROM THE OUTSIDE. ONCE THE PRE-CONSTRUCTION MILLWORK DROP / INSTALL DATE HAS BEEN
ESTABLISHED, ANY CHANGES TO THE ESTABLISHED DATE MUST BE COMMUNICATED AT LEAST 7 DAYS PRIOR.
NO MATERIAL SUBSTITUTIONS WILL BE ALLOWED UNLESS SUBMITTED IN WRITING AND APPROVED IN WRITING BY THE NEXTORE PROJECT MANAGER.
H.
THE GENERAL CONTRACTOR SHALL, ON OR BEFORE THE SOONER OF: WITHIN 10 WORKING DAYS OF CONTRACT AWARD OR THE START OF THE PROJECT, PROVIDE TO
NEXTORE AND KEEP CURRENT, A LIST OF ALL SUBCONTRACTORS TO BE USED ON THE PROJECT. THE GENERAL CONTRACTOR SHALL ALSO PROVIDE A COPY OF THIS LIST TO
THE NEXTORE PROJECT MANAGER AT CONSTRUCTION COMPLETION, AND A COPY IS TO BE INCLUDED IN THE CLOSEOUT PACKAGE FROM THE GENERAL CONTRACTOR.
I.
THE GENERAL CONTRACTOR SHALL INSPECT, VERIFY AND INVENTORY ALL SHIPMENTS OF NEXTORE SUPPLIED MATERIALS, INCLUDING THOSE TO AND FROM ANY OFF
SITE WAREHOUSE FACILITIES. THIS INCLUDES VERIFYING PACKING LISTS AGAINST ORDER FORMS AND BILLS OF LADING, AND NOTING AND REPORTING ANY DAMAGES OR
SHORTAGES TO THE NEXTORE PROJECT MANAGER. IF NOT DONE WITHIN 24 HOURS OF DELIVERY, THE GENERAL CONTRACTOR SHALL BEAR ANY AND ALL ASSOCIATED
COSTS, INCLUDING EXPEDITED FREIGHT CHARGES, TO MEET THE CONSTRUCTION SCHEDULE. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FILING DAMAGE REPORTS
AND MAINTAINING PACKING MATERIALS FOR RETURN SHIPMENT OF DAMAGED ITEMS.
K.
THE GENERAL CONTRACTOR SHALL DELIVER TO THE NEXTORE PROJECT MANAGER A COPY OF THE CERTIFICATE OF OCCUPANCY (C OF O), LIEN WAIVERS,
WARRANTIES, GUARANTEES AND EQUIPMENT OPERATION MANUALS. THE ORIGINAL CERTIFICATE OF OCCUPANCY IS TO BE LEFT WITH THE STORE GENERAL MANAGER.
REMODEL STORES: GC TO COORDINATE ALL TEMPORARY AND PERMANENT DATA AND PHONE CABLING DURING THE OPEN REMODEL.
KEEPING STORE POS AND PHONE SYSTEMS ON LINE AND ACTIVATED AT ALL TIMES. COORDINATE WORK WITH TENANT LOW VOLTAGE
VENDOR.
7. ELECTRICAL AND LIGHTING DELIVERIES
GC SHALL BE RESPONSIBLE FOR THE COORDINATION OF DELIVERIES, FOR THE OFF-LOADING OF SAME, AND TO VERIFY / REPORT ANY
DAMAGE AND FOR THE SAFE STORAGE OF ALL MATERIALS RECEIVED. THE GC SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL
EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION.
L.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEAN UP AND DISPOSAL OF ALL TRASH AND DEBRIS GENERATED BY ALL TRADES. GC. TO
REMOVE/DISPOSE OF ALL BOXES/CRATES/TRASH OF TENANT SUPPLIED AND INSTALLED ITEMS, INCL. DISPLAY FIXTURES & HARDWARE. DAILY CLEAN REQUIRED.
THESE CONSTRUCTION DOCUMENTS ARE NOT TO BE SCALED. ALL DIMENSIONS ARE TO FINISH FACE OF WALL, UNLESS OTHERWISE NOTED
N.
THESE DRAWINGS ARE NOT TO BE ALTERED IN ANY WAY WITHOUT THE WRITTEN AUTHORIZATION FROM NEXTORE OR NEXTORE'S ARCHITECT.
O.
THE GENERAL CONTRACTOR SHALL MAINTAIN EGRESS AT ALL TIMES DURING STORE OPERATION / CONSTRUCTION.
P.
THE GENERAL CONTRACTOR SHALL COORDINATE CONSTRUCTION TIMES AND NOISE REQUIREMENTS WITH LANDLORD PRIOR TO CONSTRUCTION START, NO EXTRA
COSTS WILL BE ALLOWED TO ACCOMMODATE ANY RESTRICTIONS OR LIMITATIONS.
8. METER INSTALLATION (WATER / ELECTRIC / GAS):
UTILITY ACCOUNT TRANSFER / SETUP (FOR CORPORATE NEW AND RELOCATION STORES ONLY):
GC SHALL CONTACT THE NEXTORE RETAIL STORE MAINTENANCE HOTLINE (513)765-3500 UPON ARRIVAL AT THE SITE. GC WILL NOT BE
RESPONSIBLE FOR ANY UTILITY COSTS DURING CONSTRUCTION. GC TO CONTACT NEXTORE TO CONVERT METERS TO NEXTORE NAME
IMMEDIATELY UPON CONSTRUCTION START UP. GC TO PROVIDE THE FOLLOWING INFORMATION WHEN CALLING:
A. STORE ADDRESS AND SPACE #
B. UTILITY COMPANY (S) NAME AND PHONE # (I.E., GAS, ELECTRIC, WATER AND POSSIBLY SEWER)
C. METER AND SOCKET # (IF USED)
D. EXPECTED "PUNCH" DATE (TIMING FOR NEW INSTALLATION OR UTILITY ACCOUNT TRANSFER WILL BE EXECUTED ON/OR BEFORE THE
"PUNCH" DATE).
Q.
UPON COMPLETION OF CONSTRUCTION, IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CLEAN ALL SURFACES / FIXTURES PER MANUFACTURER'S
INSTRUCTIONS AND TO EMPLOY THE SERVICES OF A PROFESSIONAL CLEANING COMPANY TO ASSURE DELIVERY TO THE TENANT OF AN ABSOLUTELY CLEAN STORE. (2)
CLEANINGS REQUIRED. (1) PRIOR TO PUNCH & (1) AT TURNOVER. THE FINAL CLEANING IS TO BE PERFORMED NO MORE THAN ONE DAY PRIOR TO THE TURN OVER. IF AN
UNTIDY STORE IS TURNED OVER, NEXTORE RESERVES THE RIGHT, WITHOUT NOTICE TO THE GENERAL CONTRACTOR, TO EMPLOY PROFESSIONAL CLEANING SERVICES AND
DEDUCT THE COST PLUS 15% FROM THE BALANCE OF THE GENERAL CONTRACTOR.
R.
THE GENERAL CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR ALL EQUIPMENT, FINISHES, MERCHANDISE, CARPET, ETC., INCLUDING THE WORK OF OTHERS,
THROUGHOUT THE DURATION OF THE PROJECT.
S.
THE GENERAL CONTRACTOR SHALL COORDINATE ALL ACTIVITIES WITH THE LANDLORD PRIOR TO THE START OF CONSTRUCTION, AND COORDINATE WITH THE
LANDLORD, ALL INTERRUPTION OF SERVICES. ANY SHUT DOWNS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR
9. TURNOVER PROCEDURE:
A. THE GC SHALL CALL THE THE NEXTORE P.M. TO CONFIRM THE TURNOVER DATE NO LATER THAN 10 WORKING DAYS BEFORE
TURNOVER.
B. ALL CONSTRUCTION ITEMS, INCLUDING ITEMS ON THE INSTALLATION SCHEDULE ARE TO BE COMPLETED BEFORE TURNOVER DAY.
C. THE GC AND NEXTORE P.M. TO CONDUCT THE PUNCH WALKTHROUGH, NOTING ALL DEFICIENCIES AND TIMING FOR RESOLUTION.
D. A "SUBSTANTIAL COMPLETION" DOCUMENT WILL BE DISTRIBUTED TO THE GC. THE GC SHALL REMAIN ON SITE UNTIL ALL "PUNCH
LIST" ITEMS ARE COMPLETE AND THE NEXTORE PM HAS SIGNED OFF CONFIRMING COMPLETION OF THE "PUNCH LIST".
E. A COPY OF THE "CONFIRMED COMPLETION OF PUNCH LIST" WILL BE GIVEN TO THE NEXTORE P.M.
T.
THE GENERAL CONTRACTOR SHALL INSTALL A LANDLORD AND CODE COMPLIANT TEMPORARY BARRICADE AS REQUIRED BY THE LANDLORD OR NEXTORE PROJECT
MANAGER, UNLESS THE PLANS SPECIFICALLY CALL OUT FOR THIS WORK TO BE BY OTHERS.
U.
GENERAL CONTRACTOR SHALL INSTALL A TEMPORARY ENTRANCE WITH DOORS, FRAMES AND LOCKS, UNLESS THE PLANS SPECIFICALLY CALL OUT FOR THIS WORK TO
BE BY OTHERS.
V.
ALL CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CODES AND ORDINANCES, THE LANDLORD'S TENANT DESIGN CRITERIA, THE LANDLORD'S CONSTRUCTION
RULES AND REGULATIONS, NEXTORE STANDARD SPECIFICATIONS, NEXTORE'S STANDARD CONSTRUCTION CRITERIA AND ACCEPTED BEST CONSTRUCTION PRACTICES. THE
GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO FILE ANY NEEDED "NOTICE OF COMMENCEMENT" OR OTHER FILINGS RELATED TO THE PROJECT IN THE APPROPRIATE
OFFICES AND SHALL BE RESPONSIBLE TO POST SUCH NOTICES AT THE JOB SITE.
W.
ALL WOOD CONSTRUCTION, INCLUDING BLOCKING, SHALL BE FIRE RESISTANT TREATED (FRT). ALL NEW FRAMING AT THE STOREFRONT AND / OR ABOVE THE CEILING
SHALL BE NON-COMBUSTIBLE.
X.
THE GENERAL CONTRACTOR SHALL, PRIOR TO BEGINNING ANY WORK, COORDINATE WITH THE LANDLORD OR ANY AUTHORITY HAVING JURISDICTION, AND BEAR THE
COSTS FOR, ALL EXPLORATIONS / X-RAYS REQUIRED FOR CUTTING/CORING OF THE SLAB OR EXCAVATING.
Y.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WITH THE STRUCTURE AND
SHELL BUILDING ELEMENTS. THE GENERAL CONTRACTOR SHALL IMMEDIATELY NOTIFY THE NEXTORE PROJECT MANAGER OF ANY DISCREPANCIES BETWEEN THESE DRAWINGS
AND THE BUILDING SHELL.
Z.
THE GENERAL CONTRACTOR SHALL PROVIDE ALL FIRE EXTINGUISHERS, CONCEALED BLOCKING AND SIGNAGE FOR SAME AS REQUIRED. QUANTITIES, SIZES AND
LOCATIONS SHOWN IN THE DRAWINGS ARE ONLY SUGGESTED QUANTITIES, SIZES AND LOCATIONS, THE MOST STRINGENT REQUIREMENT OF ANY BODY HAVING
JURISDICTION SHALL PREVAIL.
AA. THE GENERAL CONTRACTOR SHALL DESIGN, INSTALL, LOCATE, RELOCATE, RECONFIGURE THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS AS REQUIRED BY THE INTENT
OF THESE CONSTRUCTION DOCUMENTS OR ANY CODE OR BODY HAVING JURISDICTION OVER THE WORK. ALL FIRE SPRINKLER AND FIRE ALARM SYSTEM WORK SHALL BE
'DESIGN BUILD' BY THE GENERAL CONTRACTOR, UNLESS CALLED OUT TO BE PERFORMED SPECIFICALLY BY OTHERS IN THE DOCUMENTS (SEE FIRE SPRINKLER SYSTEM / FIRE
ALARM SYSTEM NOTES. GC TO COORDINATE WITH LANDLORD REQUIRED VENDOR.
AB.
RESERVED
AC.
THE GENERAL CONTRACTOR SHALL, WITHOUT EXCEPTION, PROVIDE AND INSTALL ANY AND ALL DUST PROTECTION, REQUIRED DURING CONSTRUCTION.
AD.
GENERAL CONTRACTOR TO PROVIDE ALL FLOOR PREPARATION AS NEEDED TO ASSURE COMPLIANCE WITH FINISHED FLOORING MANUFACTURER SPECIFICATIONS.
AE.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL CEILING WORK WITH THE MEP DRAWINGS.
AF.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL LIGHTING WITH THE ELECTRICAL DRAWINGS / REFLECTED CEILING PLAN.
10. SETDOWN FOR NEW CORPORATE STORES:
NEXTORE'S NEW STORE TEAM WILL DELIVER ALL REMAINING OWNER FURNISHED ITEMS TO THE STORE ON THE EVENING OF
"TURNOVER" DAY. THE GC SHALL BE ON SITE ON THE DAY AFTER "TURNOVER", WITH ONE (1) PLUMBER AND ONE (1) ELECTRICIAN
TO ASSIST THE SETDOWN TEAM TO RESOLVE ANY ISSUES. THE GC SHALL SUPPLY DUMPSTER FOR REMOVAL OF SETDOWN DEBRIS.
11. SOUND SYSTEM:
A. THE GC SHALL BE RESPONSIBLE TO CONTACT SOUND VENDOR 4 WEEKS PRIOR TO THE SCHEDULED DATE TO ARRANGE FOR
INSTALLATION.
B. REMODELS AND RELOCATIONS: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL, STORAGE AND
REINSTALLATION OF SYSTEM (INCLUDING CD PLAYERS AND SPEAKERS) AT NEXTORE STORES DURING DURATION OF
CONSTRUCTION.
12. SECURITY ALARM TRANSFER/MODIFICATION
A. ALARM TRANSFER / MODIFICATION - GC SHALL CONTACT THE SECURITY VENDOR DURING ANY POINT IN CONSTRUCTION THE
GC DETERMINES THEY WILL NEED TO DISABLE OR RELOCATE ANY ALARM SYSTEM COMPONENTS. GC SHALL AWAIT
INSTRUCTIONS FROM THE "NEXTORE SECURITY LIAISON" BEFORE TAKING ANY ACTION ON THE SECURITY SYSTEM.
B. CAMERAS - GC SHALL CONTACT THE "NEXTORE LOSS PREVENTION MANAGER" TO COORDINATE THE REINSTALLATION OF
SECURITY CAMERAS ON REMODEL OR RELOCATION STORES THAT ALREADY HAVE CAMERAS IN PLACE AND ARE BEING
DISTURBED DURING CONSTRUCTION.
13. AIR BALANCE REPORTS
G.C. RESPONSIBLE TO OBTAIN AIR BALANCING REPORT FROM A VENDOR INDEPENDENT FROM THE HVAC CONTRACTOR.
AG. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL LIGHT FIXTURES SUPPORTS, INCLUDING ANY AND ALL SEISMIC
REQUIREMENTS.
AH.
AJ.
THE GENERAL CONTRACTOR SHALL RECEIVE, UNLOAD, AND PROVIDE SAFE STORAGE OF ALL NEXTORE / NEXTORE SUPPLIED AND / OR INSTALLED MATERIAL. TRASH
REMOVAL OF ALL BOXES / CRATES CONTAINING NEXTORE / NEXTORE SUPPLIED AND / OR INSTALLED MATERIAL, INCLUDING BUT NOT LIMITED TO FLOORING, MILLWORK,
LIGHTING, HARDWARE, ACCESSORIES, EQUIPMENT, ETC. SHALL BE BY THE GENERAL CONTRACTOR.
AK. NOTICE OF INCIDENT: THE GENERAL CONTRACTOR SHALL, VIA ELECTRONIC MEDIUM AND NEXTORE STANDARD NOTIFICATION AND REPORTING FORMS, IMMEDIATELY
NOTIFY THE NEXTORE PROJECT MANAGER OF ANY INCIDENT INVOLVING THE PROJECT WHICH RESULTS IN CONTACT WITH ANY FEDERAL, STATE OR LOCAL GOVERNMENT
AGENCY OR AS CALLED OUT IN NEXTORE'S OR THE LANDLORDS RULES, REGULATIONS OR POLICIES.
AL.
WEEKLY PROGRESS PHOTOS, DAILY REPORTS, SAFETY INSPECTIONS, SCHEDULE UPDATES, CHANGE ORDER LOGS, RFI LOGS, AND TOOL BOX TOPICS SHALL BE
SUBMITTED TO THE NEXTORE PROJECT MANAGER VIA EVOCO AS REQUIRED IN THE DOCUMENTS OR DIRECTED BY THE NEXTORE PROJECT MANAGER.
AM. FOR THOSE PROJECTS THAT ARE “OPEN REMODELS”; STORES WILL REMAIN OPEN DURING REGULAR BUSINESS HOURS WHILE CONSTRUCTION IS IN PROGRESS. ALL
DISTURBANCES TO SURROUNDING BUSINESSES AND AREAS MUST BE KEPT TO A MINIMUM. WORK DURING AN OPEN REMODEL IS TYPICALLY PERFORMED "AFTER NORMAL
OPERATING HOURS." GC MUST COORDINATE WITH NEXTORE PROJECT MANAGER AND OR STORE OPERATIONS MANAGER PRIOR TO CONSTRUCTION START. THERE SHALL BE
NO UP-CHARGE SUBMITTED, ALLOWED, OR CONSIDERED FOR ANY SUCH AFTER HOURS WORK.
SAFETY:
SAFETY OF ALL EMPLOYEES, ASSOCIATES AND CUSTOMERS SHALL BE THE NUMBER ONE PRIORITY FOR ALL CONTRACTORS ON ANY NEXTORE PROJECT. OSHA
REQUIREMENTS SHALL BE INCORPORATED INTO THE SCOPE OF WORK EVEN THOUGH THEY MAY NOT BE LISTED SEPARATELY. CONTRACTOR SHALL MAINTAIN A COPY OF
THEIR SITE SPECIFIC SAFETY PLAN ON SITE AT ALL TIMES
REV0.1
VICINITY PLAN
AREA OF PROJECT
1
By
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
PROJECT LOCATION
STREET ADDRESS
5135 WEST ALABAMA
CITY, STATE, ZIP
HOUSTON, TX 77056
PHONE
EMAIL:
513.262.0587
[email protected]
MACY'S STORE INFO
MACY'S #687
STORE CONTACTS
DAVID BOESSENECKER
STREET ADDRESS
5135 WEST ALABAMA
CITY, STATE, ZIP
HOUSTON, TX 77056
Architect of Record
TELEPHONE:
EMAIL:
[email protected]
JURISDICTION
ASSOCIATES INC.
NORTH
CITY
HOUSTON, TX
DEPARTMENT
CITY OF HOUSTON BUILDING DEPARTMENT
STREET ADDRESS
1002 WASHINGTON AVE
CITY, STATE, ZIP
HOUSTON, TX
PHONE
832-394-9000
2016-026A
Seal
MALL NAME
GALLERIA AT HOUSTON
STREET ADDRESS
5135 WEST ALABAMA
CITY, STATE, ZIP
HOUSTON, TX 77056
SPACE NUMBER
FIRST FLOOR
M (MERCANTILE) / NO CHANGE
BUILDING:
2012 IBC, W/ HOUSTON AMENDMENTS
MECHANICAL:
2012 UNIFORM MECHANICAL CODE W/ HOUSTON AMENDMENTS
PLUMBING:
2012 UNIFORM PLUMBING CODE W/ HOUSTON AMENDMENTS
FIRE:
2012 INTERNATIONAL FIRE CODE W/ HOUSTON AMENDMENTS
ELECTRICAL
2014 NATIONAL ELECTRICAL CODE W/ HOUSTON AMENDMENTS
ENERGY:
2009 IECC, W/ HOUSTON AMENDMENTS
AREA C
AREA B
ACCESSIBILITY CODE: 2012 TEXAS ACCESSIBILITY STANDARDS & 2009 1CC A117.1
AREA A
KEYPLAN
HOUSTON CONSTRUCTION CODE AMMENDMENTS
EGRESS: EXISTING MACY'S 1st FLOOR
MERCANTILE
850 sf / 30 gross
TOTAL
850 sf TOTAL
=
29
2 EXITS FOR OCCUPANCY > 49
29 TOTAL
AREA B
MERCANTILE
TOTAL
700 sf / 30 gross
700 sf TOTAL
=
24
G001
GENERAL INFORMATION COVER SHEET
-
G002
RESPONSIBILITY SCHEDULE / ABBREVIATIONS
-
G003
SPECIFICATIONS 1 of 2
-
G004
SPECIFICATIONS 2 of 2
-
V100
MACY'S EXISTING 1ST FLOOR PLAN
-
AD100A
DEMOLITION FLOOR & CEILING PLANS: AREA A
-
AD100B
DEMOLITION FLOOR & CEILING PLANS: AREA B
A100
FIXTURE FLOOR PLAN
-
A101
CONSTRUCTION FLOOR PLAN
-
A102
REFLECTED CEILING PLAN
-
A103
FINISH PLAN
-
A200
INTERIOR ELEVATIONS
-
A300
WALL TYPES
-
A400
MISCELLANEOUS SECTIONS & DETAILS
-
NAME:
GLENN S. YEAKEL
DATE:
07-01-16
REG NO:
20474
Engineer
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
MINIMUM NUMBER OF EXITS: TABLE 1015.1
AREA A & B
OCCUPANT LOAD: TABLE 1004.1.1
ACTIVE REVISION
NUMBER
ARCHITECTURAL
SPRINKLERED:
FULLY
FIRE ALARM:
YES
FIRE EXTINGUISHERS: YES
OCCUPANCY:
AREA A
DRAWING TITLE
CONSTRUCTION OF THE NEW LENSCRAFTERS DEPT. NO CHANGE OF
EGRESS OF OR OCCUPANCY OF THE MACY'S STORE.
REV 0.2
CONSTRUCTION TYPE: II-B
ADDITIONAL CODES
DRAWING INDEX
JOB SITE ADDRESS
CODE INFORMATION
281 Farmington Avenue
Farmington, CT. 06032
NORTH
REQ'TS MET; REF: SHEET V100
FOR EGRESS LOCATIONS
MECHANICAL
MINIUMUM PLUMBING FIXTURES
MPE100
PLUMBING CODE; TABLE 403.1
24 TOTAL
Seal
MECHANICAL & PLUMBING OVERALL BUILDING PLANS
-
H100
HVAC SPECIFICATIONS AND DEMOLITION PLAN
-
H200
HVAC PLANS AND DETAILS
-
AREA A
AREA A
EGRESS WIDTH PER OCCUPANT: TABLE 1005.3.1
STAIRS: 0.20"/PERSON OTHER EGRESS: 0.15"/PERSON
29 OCCUPANTS x 0.15" = 4.35"
65' OPEN PERIMETER
AT TENANT SPACE
AREA B
24 OCCUPANTS x 0.15" = 3.6"
EGRESS DOOR: 33" CLEAR WIDTH
W/C
LAVATORIES
DRINKING FOUNTAINS
SERVICE SINKS
1/500
1/750
1/1000
1
1
1
1
1
AREA B
W/C
LAVATORIES
DRINKING FOUNTAINS
SERVICE SINKS
1/500
1/750
1/1000
1
1
1
1
1
11
9
2
1
11
9
2
1
PROJECT DIRECTORY
NEXTORE
NEXTORE
6 CREAMERY BROOK
EAST GRANBY, CT 06026
516.393.2484
4000 LUXOTTICA PLACE
MASON, OH 45040
513.765.6000
PLUMBING
P100
PLUMBING SPECIFICATIONS
-
P200
PLUMBING PLANS AND DETAILS
NAME:
DATE:
ELECTRICAL
MELISSA LUCE
TEL 860.462-9349
FRIAR ASSOCIATES, INC
281 FARMINGTON AVENUE
FARMINGTON, CT 06032
CONTACT: LINDA BLASZKA
TEL: 860.678-1291
FAX: 860.677-5265
EMAIL: [email protected]
MICAH WASHINGTON
FRIAR ASSOCIATES II, LLC
281 FARMINGTON AVENUE
FARMINGTON, CT 06032
CONTACT: ADAM PALMER
TEL: 860.678-1291
FAX: 860.677-5265
EMAIL: [email protected]
COMPANY
STREET
CITY, STATE, ZIP
CONTACT
TEL
FAX
EMAIL
N/A
RETAIL PERMIT GROUP
600 ANTON BLVD, 11TH FL
COSTA MESA, CA 92626
CONTACT: DARREN BAYSA
TEL: 714.975-9708
FAX: 714.975-9758
EMAIL: [email protected]
REG NO:
E100
ELECTRICAL SPECIFICATIONS, SYMBOLS & DEMO PLAN
-
E200
ELECTRICAL POWER & LOW VOLTAGE PLAN & DETAILS
-
E201
ELECTRICAL LIGHTING PLAN AND DETAILS
-
E300
ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULE
-
E400
CASEWORK DETAILS
-
THE SCOPE OF THIS BUILDOUT WILL INCLUDE: (ONLY IN AREA DETAILED ON SHEET V100)
MINOR WALL & CEILING DEMOLITION, AS REQUIRED TO FACILITATE DESIGN
CONSTRUCTION OF NEW NON LOAD BEARING WALLS
NEW FLOORING FINISHES
NEW CEILING
NEW FURNITURE AND FIXTURES
NEW OD OFFICE EQUIPMENT
NEW SIGNAGE AND GRAPHICS
UTILITY WORK AS REQUIRED TO ACCOMMODATE PROJECT SCOPE
Date
07/07/16
CONST. COORDINATOR MANNY WEINSTEIN
THIS PROJECT IS THE TENANT BUILDOUT OF AN EXISTING MERCANTILE SPACE IN AN EXISTING INTERIOR SHOPPING CENTER AND
INCLUDES INTERIOR CONSTRUCTION.








Mark
MACY'S CORPORATE SERVICES
LANDLORD
SCOPE OF WORK
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING REQUIRED FIRE RATINGS AND FIRE PROOFING IN ALL INSTANCES.
AI.
ALL PENETRATIONS OF DEMISING WALLS, ROOF AND FLOOR SHALL BE FIRE SAFE / PROOF PER CODES / LANDLORD REQUIREMENTS. THE MOST STRINGENT
REQUIREMENT SHALL PREVAIL.
MACY'S 1st FLR KEY PLAN
6. DATA-POS / PHONES:
NEW T.I. & RELO STORES: BACKBOARD TO BE INSTALLED WITHIN 7 CALENDAR DAYS OF THE CONSTRUCTION START DATE. ACCESS TO
BACKBOARD SHALL BE AFFORDED TO ALL TENANT VENDORS. TELEPHONE, ELECTRIC AND DATA CABLING INSTALLED ONE WEEK BEFORE
"PUNCH" FOR HARDWARE INSTALLATION AND TESTING. CONTACT NEXTORE P.M. IF NEEDED.
J.
THE GENERAL CONTRACTOR SHALL KEEP ALL HANDBOOKS, MANUALS, WARRANTY DOCUMENTS AND MISCELLANEOUS PAPERWORK, INCLUDING ALL PACKING SLIPS
AND BILLS OF LADING IN A MARKED BINDER. THIS BINDER IS TO BE TURNED OVER TO THE STORE GENERAL MANAGER AT PROJECT COMPLETION. COPIES OF THOSE ITEMS
AND DOCUMENTS REQUIRED FOR INCLUSION IN THE CLOSEOUT PACKAGE SHALL BE MADE BY THE GENERAL CONTRACTOR AS NEEDED FOR THIS SUBMISSION.
M.
BUILDING DATA
LANDLORD'S ADDRESS
Revisions:
FR I A R
GENERAL NOTES
Macy's Store Number: (687)
Nextore project
Number
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
DEFERRED SUBMITTALS
THE AWARDED GENERAL CONTRACTOR SHALL ENGAGE THE
REQUIRED MACY'S VENDORS AND SUBMIT FOR SEPARATE PERMIT
FIRE ALARM AND SPRINKLER WORK.
73052
Date
GENERAL
INFORMATION
COVER SHEET
07-01-16
Drawn By
LLB
Checked By
ANP
Sheet
G001
T=
TENANT
GC= GENERAL CONTRACTOR
LL= LANDLORD
MW= MILLWORKER
N/A= NOT APPLICABLE
NOTE: THE GENERAL CONTRACTOR SHALL VERIFY ALL ITEMS ON THIS SCHEDULE FOR
ACCURACY PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES SHALL BE
REPORTED TO LUXOTTICA PROJECT MANAGER IMMEDIATELY.
SUPL
RCV. INSTL EX'G
BUILDING PERMIT
PROFESSIONAL CLEAN-UP, FINAL CLEANING
DEMOLITION
TEMPORARY FACILITIES / UTILITIES
OTHER PERMITS, FEES, INSURANCE
TEMPORARY BARRICADES (W/ LUX BRAND SPECIFIC LOGO)
T
GC
GC
GC
GC
GC
GC
GC
GC
GC GC
GC
GC
TRASH REMOVAL AND DUMPSTERS
GC GC
CUTTING AND PATCHING
RELOCATION OF EXISTING MACY'S FIXTURES
GC GC GC
ASSET PROTECTION COORDINATION
INSURANCE
GC
GC
DIVISION 03000 - CONCRETE
SUPL
DIVISION 05000 - MISC. METALS
SUPL
IF OVERNIGHTS REQUIRED, GC SHALL PAY AP VENDOR & COORDINATE OVERNIGHT POWER W OPS MANAGER.
GC TO ADD MACYS AS AN ADDITIONALLY INSURED PARTY ON CERTIFICATE OF LIABILITY INSURANCE. CERTIFICATES NEED TO BE SENT
TO THE NEXTORE PROJECT MANAGER. NEXTORE PROJECT MANAGER TO FORWARD TO THE MACY'S PROJECT MANAGER.
RCV. INSTL EX'G
RCV. INSTL EX'G
RCV. INSTL EX'G
GC
GC
GC
GC
DIVISION 07000 - THERMAL & MOISTURE PROTECTION
SUPL
RCV. INSTL EX'G
SEALANTS, INSULATION, FIRE CAULKING & BLOCKING
SPRAYED FIRE RESISTIVE MATERIALS
THROUGH PENETRATIONS FIRE STOP SYSTEM
BATT INSULATION AND/OR SOUND ATTENUATION
WATERPROOF MEMBRANE
GC
GC
GC
GC
GC
GC
GC
GC
GC
GC
DIVISION 08000 DOORS & WINDOWS
SUPL
RCV. INSTL EX'G
RELO
GC
GC
GC
GC
T
GC
GC
GC
GC
GC
GC
GC
GC
GC
T
GC
GC
GC
GC
GC
GC
GC
T
GC
GC
T
T
T
T
T
T
T
GC
GC
GC
GC
GC
T
T
T
T
T
T
GC
GC
GC
T
GC
GC
T
T
T
T
T
T
T
RELO
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
REMARKS
ALL MILLWORK LIGHTING IS PLUG & PLAY
Macy's Store Number: (687)
GC TO REFER TO ELECTRICAL RISER DIAGRAM
WIRING AND FINAL CONNECTIONS BY GC
PROVIDE NEW DEVICES AND/OR MODIFY AS REQUIRED. UTILIZE LANDLORD REQUIRED FIRE ALARM VENDOR.
GC TO RELOCATE WHEN APPLICABLE / MATCH EXIST. WIRE AND EXTEND
WIRING TO BE PLENUM RATED
G.C. TO COORDINATE
WIRING TO BE PLENUM RATED
TENANT'S LOW VOLTAGE VENDOR PERFORMS DATA TERMINATIONS
GC SHALL PROVIDE ALTERNATE PRICE - SEE ELECTRICAL SHEETS. WIRING TO BE PLENUM RATED
Revisions:
Mark
Date
1
GC SHALL PROVIDE ALTERNATE PRICE - SEE ELECTRICAL SHEETS.
By
07/07/16
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
GC SHALL PROVIDE ALTERNATE PRICE - SEE ELECTRICAL SHEETS.
WIRING TO BE PLENUM RATED
REMARKS
Architect of Record
FIRE RETARDENT WOOD AND METAL PER AUTHORITY JURISDICTION / LL
DURABLE PROTECTION REQUIRED. PROVIDE WALK-OFF MAT AT BOTH SIDE OF ENTRY POINT(S) OF CONSTRUCTION AREA
RELO
GC
GC
GC
GC
GC
REMARKS
SEE SPECIFICATIONS
IF REQUIRED BY LL
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
EXTENTS OF WATERPROOF MEMBRANE SHALL BE VERIFIED W LL BY THE GC
REV 0.7
SUPL
RCV. INSTL EX'G
T
T
T
T
T
GC
GC
T
T
GC
GC
GC
GC
GC
GC
T
SUPL
RCV. INSTL EX'G
T
T
T
T
T
T
GC
T
T
T
DIVISION 15000 - MECHANICAL
SUPL
VINYL BASE @ ROUND COLUMNS
CARPET TILE C-63 WILL BE NEXTORE FURNISHED, GC INSTALLED, UNLESS SPECIFIED ON THE DRAWINGS. ANY SPECS OTHER THAN
C-63 WILL BE GC SUPPLIED AND INSTALLED (INCLUDING BORDERS OR MATCHING EXISTING MACY'S CARPET SPECS). GC MUST INSTALL
FLOOR PER FLOORING MFG SPECS. REFER TO FINISH SCHEDULE SHEET A103.
ACCESS PANELS
ROOF WORK
HVAC DISTRIBUTION, DUCTWORK, DIFFUSERS
GC GC GC
GC GC GC
GC GC GC
PLUMBING FIXTURES
GC/T
GC GC
OD SINKS
FLOOR DRAINS / PIPING / SUPPORTS
WATER AND SEWER CONNECTION
SPRINKLER SYSTEM MODIFICATIONS
SANITARY PUMP (ALL COMPONENTS)
SANITARY BOOSTER
INSTA-HOT WATER HEATERS
MW
GC
GC
GC
GC
GC
GC
GC
GC
GC
GC
GC
GC
GC
PAINTED P104
X
REMARKS
G.C. TO COORDINATE SIGN INSTALLATION
SEE FIXTURE PLAN FOR MORE INFORMATION
SEE FIXTURE PLAN FOR MORE INFORMATION
SEE FIXTURE PLAN FOR MORE INFORMATION
SEE FIXTURE PLAN FOR MORE INFORMATION
NOTE: y=54 in. (1370 mm)
minimum if door has both a
latch and a closer
NOTE: y=48 in. (1220 mm)
minimum if door has both a
latch and a closer
DATE:
07-01-16
REG NO:
20474
Clear
Floor
Space
48 min.
1220
6 max. Toe Clearance
150
Knee Clearance
8 min
205
Latch-side Approaches - Swinging Doors
SUGGESTED LOCATION ON PLAN - VERIFY LOCAL REQUIREMENTS
19 max.
485
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
17 min. Lav. Depth
430
Lavatory Clearances
REMARKS
RECEIVED & OFFLOADED BY G.C. / UNCRATED & INSTALLED BY TENANT
RECEIVED & OFFLOADED BY G.C. / UNCRATED & INSTALLED BY TENANT
G.C. TO COORDINATE
G.C. TO COORDINATE
NOTE:
LAVATORY HAS LEVER OR EQUAL FAUCET HARDWARE
AND THE PIPES UNDER THE SINK ARE INSULATED OR
OTHERWISE COVERED.
Seal
Counter
30 min.
760
30 min.
760
FRAMES ORDERED BY FIELD TEAM INSTALLED BY G.C.
RELO
GLENN S. YEAKEL
Engineer
17 min.
430
760
24 min.
610
COMPLETE FINISH BY MW
24 min.
610
PUSH SIDE
30 min.
X
PULL SIDE
RELO
NAME:
NOTE: All doors in alcoves shall comply
with clearances for front approaches.
GC TO COORD. WITH LANDLORD. PROVIDE SAMPLE AND RECEIVE APPROVAL. GC MUST INSTALL FLOOR PER FLOORING MFG SPECS
RELO
NOTE: y=48 in. (1220 mm)
minimum if door has both a
latch and a closer
Hinge-side Approaches - Swinging Doors
Front Approaches - Swinging Doors
Suggested
Supply Lines
Base Height
Cabinet Heights
GC
GC
GC
GC
GC
GC
GC
Y
42 min.
1065
NOTE: x=36 in. (915 mm) minimum
if y = 60 in. (1525 mm) :
x =42 in. (1065 mm) minimum
if y = 54 in.
NOTE: x=12 in. (305 mm) if the door
has both a closer and a latch
GC MUST INSTALL FLOOR PER FLOORING MFG SPECS.
MW MW
MW MW
T T
T T
T T
GC GC
GC GC
GC GC
GC GC
GC GC
RCV. INSTL EX'G
Y
SEE PLANS FOR SCOPE OF WORK
SEE PLANS FOR SCOPE OF WORK.
PER USG AETHETIC ASSEMBLIES, ALL WALLS (INCLUDING EXISTING TO REMAIN), SHALL RECEIVE "LEVEL 4" FINISH, & CEIL "LEVEL 5"
T
GC
T
T
GC
GC
GC
T
MILLWORK (RETAIL)
MILLWORK (O.D.)
OD EQUIPMENT
POS EQUIPMENT
LENS PROCESS EQUIPMENT
MERCHANDISE PROPS
SHELVES & STANDARDS (OD/EMPLOYEE AREA)
FURNITURE (CHAIRS, BENCHES, TABLES, ETC.)
STAPLES PURCHASED ITEMS
DOCTOR'S CERTIFICATES / LICENSES
X
34
T GC GC
GC GC GC
GC GC GC
GC GC GC
T GC GC
T GC GC
MW MW MW
GC GC GC
GC GC GC
GC GC GC
22 min
27 min.
685
9 min.
230
PORCELAIN FLOOR TILE
GROUT AND THINSET FOR TILE & ACCESSORIES
FLOORING TO MATCH EXISTING MACY'S FLOORING
FLOORING TRANSITION STRIPS
WALLCOVERING
WALLTILE
CUSTOM WOOD MILLWORK WD201
3/4" X 3/4" WOOD TRIM
WOOD TRIM (OPEN DOOR SURROUND)
WOOD BASEBOARD WB101
GC
GC
GC
GC
GC
GC
GC
REMARKS
PUSH SIDE
PULL SIDE
40 max.
34 max.
GC
GC
GC
GC
GC
GC
GC
RELO
18 min
455
PUSH SIDE
48 min.
1220
GC
GC
GC
GC
GC
GC
X
PULL SIDE
1065
RCV. INSTL EX'G
2016-026A
Seal
UNLESS NOTED OTHERWISE. (SEE DOOR SCHEDULE SHEET A101)
IF EGRESS DOOR REQUIRED
GC
GC
GC
GC
GC
GC
SUPL
REMARKS
Y
42 min
GC
GC
GC
GC
GC
GC
RELO
34
GC
GC
T
GC
MW
GC
T/GC
DIVISION 12000 - FURNISHINGS
REMARKS
RCV. INSTL EX'G
GC
GC
GC
GC
T
T
T
GC
T
GC
+1 (513) 765-6000
p
N/A
GC
GC
GC
GC
NEW DEMISING PARTITIONS (STUDS & INSTALLATION)
NEW DEMISING PARTITIONS (GYPSUM WALLBOARD)
DRYWALL CEILING, WALLS, ENCLOSURES & REQ'D FRAMING
ACOUSTICAL CEILING 2'x2' TILES & GRID
PAINTING, FINISHING, VARNISH, SEALER, ETC.
FLOOR TRANSITIONS/VINYL TILE / VINYL WALL BASE
CARPETING
RETAIL WALL SIGNAGE
GRAPHIC HOLDER
GRAPHICS
GRAPHICS VINYLS AND BARRICADE GRAPHICS
ACCESSIBILITY SIGNAGE
STORAGE AREA SHELVES & SURFACE MTD. STANDARDS
FIRE EXTINGUISHERS
GLAZING FILM - GRAPHIC
RELO
REMARKS
SUPL
p
6 Creamery Brook, East Granby, CT 06026
FR I A R
RCV. INSTL EX'G
GC
GC
GC
GC
DIVISION 10000 - SPECIALTIES
RELO
CONNECTION AND WIRING @ MILLWORK THROUGHOUT
ELECTRICAL SERVICE CONDUIT ONLY
ELECTRICAL PANELS / TRANSFORMERS
ELECTRICAL WIRING, CIRCUITING, RECEPTACLES, SWITCHES
RECEPTACLES IN MILLWORK
EMERGENCY LIGHTING
EXIT SIGNS
FIRE ALARM SYSTEM
NEW LIGHT FIXTURES & LAMPS
REPLACEMENT OR MATCHING EXISTING LIGHT FIXTURES & LAMPS
SOUND SYSTEM SPEAKERS
TELEPHONE CONDUIT TO SPACE
TELEPHONE WIRING TO SPACE
TENANT TELEPHONE EQUIPMENT
TELEPHONE WIRING
CONDUITS - DATA, COMMUNICATION, ALARMS, PHONES
POS AND DATA WIRING
WIRELESS EQUIPMENT
JACK TERMINATION & FACEPLATE - DATA
MACY'S BACKBOARD TERMINATION - DATA
JACK TERMINATION & FACEPLATE - PHONE
MACY'S BACKBOARD TERMINATION - PHONE
SECURITY - FACILITY (HARDWARE & WIRING)
4000 Luxottica Place, Mason, OH 45040
a
GC GC GC
SUPL
DIVISION 09000 - FINISHES
REMARKS
G.C. TO FIELD VERIFY EXIST. COND. TO DETERMINE EXTENTS OF SCOPE. GC TO REPORT TO PROJECT MANAGER.
COORD. W/ LANDLORD & AFFECTED TENANTS. VERIFY W MACY'S OPERATIONS PRIOR TO ANY CORING OR TRENCHING.
GC GC GC
BLOCKING (INCL. FOR FIXTURES, SHELVES, SIGNS
ROUGH CARPENTRY, FIRE RETARDANT LUMBER & PLYWD
FLOOR PROTECTION (IF REQUIRED)
FINISH CARPENTRY
NEW DOORS, FRAMES, HARDWARE
PANIC / SECURITY ALARM
INTERIOR DOOR LOCK CORES AND KEYS
ACCESS DOORS AND FRAMES
MILLWORK MIRRORS
WALL MOUNTED/FRAMED MIRRORS
RELO
DIVISION 16000 - ELECTRICAL
48 max.
1220
DIVISION 06000 - WOOD & PLASTICS
LL GC TO VERIFY UPON ARRIVAL ON JOB SITE THAT THE SITE HAS BEEN CLEARED OF ALL MAC'Y FIXTURES IN ORDER TO PERMORM AREA
CONSTRUCTION. NOTIFY NEXTORE PROJECT MANAGER OF ANY QUESTIONABLE ITEMS EXISTING.
GC GC GC
GC GC GC
SUPL
BASE BUILDING STRUCTURAL STEEL
STRUCTURAL STEEL AS REQUIRED FOR TENANT BUILD-OUT
METAL FABRICATIONS
EXPANSION JOINTS
INCLUDING ALL LOCAL PEST CONTROL REQUIREMENTS, PERMITS, VERIFY REQUIREMENTS
COORDINATE WITH LANDLORD. LOGO SUPPLIED BY TENANT, INSTALLED BY GC
VERIFY TOWN AND LANDLORD REQUIREMENTS. GC. TO REMOVE/DISPOSE OF ALL BOXES/CRATES/TRASH OF TENANT SUPPLIED AND
INSTALLED ITEMS, INCL. DISPLAY FIXTURES & HARDWARE. DAILY CLEAN REQUIRED.
LL
DIVISION 04000 - MASONRY
REMARKS
GC SHALL AMEND / PICK UP PERMIT & PAY ADD'TL FEES; FEES BILLABLE TO NEXTORE AT NET COST; VIA CHANGE ORDER #1
(2) CLEANINGS REQUIRED. (1) PRIOR TO PUNCH & (1) AT TURNOVER
FIELD VERIFY EXISTING CONDITIONS AND SEE PLANS FOR SCOPE
IF REQUIRED
60 min.
1525
CONCRETE SLAB (NEW OR PATCH FILL)
CUTTING OF EXISTING SLAB-TRENCHING OR CORE DRILLING
RELO
Y
48 min.
1220
DIVISION 01000 - GENERAL
T=
TENANT
GC= GENERAL CONTRACTOR
LL= LANDLORD
MW= MILLWORKER
N/A= NOT APPLICABLE
a
REMARKS
NAME:
COORDINATE WITH TRADES FOR SIZE AND LOCATION.
GC TO COORD. W/ LANDLORD WHEN REQUIRED
DATE:
SEE PLUMBING SPEC. FOR CLARIFICATION OF PLUMBING FIXTURES SUPPLIED BY
TENANT AND/OR G.C.
PROVIDED BY MILLWORKER
GC SEE PLUMBING DRAWINGS FOR SCOPE OF WORK
GC BY L.L. DESIGNATED CONTRACTOR AT G.C. EXPENSE. GC RESP. FOR MODIFICATIONS, DRAWINGS, AND APPROVALS.
GC SHALL PURCHASE PUMP FROM NEXTORE'S REQUIRED VENDOR. SEE PLUMBING SHEETS FOR CONTACT INFORMATION.
1. THIS PROJECT WILL COMPLY WITH ALL IAC 400.310 REQUIREMENTS UNDER IAC
400.320(n) - TENANT FINISHING WORK AND IAC 400.320(h) - BUSINESS AND
MERCANTILE.
2. THIS PROJECT WILL COMPLY WITH ALL FEDERAL REQUIREMENTS UNDER ADAAG
4.1.3 - NEW CONSTRUCTION AND ADAAG 140 - BUSINESS AND MERCANTILE.
3. ALL DOORS LEADING TO REQUIRED ACCESSIBLE ROOMS AND SPACES SHALL BE A
MIN. OF 3'-0" WIDE, HAVE LEVER OPERATED HARDWARE ( OR EQUAL), HAVE A MIN.
OPENING FORCES OF 5 LBF, AND FULLY COMPLY WITH IAC 400.310 (j)
4.
ALL NEW OR ALTERED ENVIRONMENTAL CONTROL AND OPERATING MECHANISMS
WILL COMPLY WITH IAC 400.310(r) (FRONT REACH BETWEEN 15" ANF 48" A.F.F.)
5. ANY NEW EMERGENCY WARNING ALARMS, WHERE PROVIDED, SHALL BE BOTH
AUDIBLE AND VISUAL AND COMPLY WITH IAC 400.810(s). THE VISUAL ALARMS
WILL BE FLASHING TYPE WHERE THE FLASHING IS SYNCHRONIZED AND IN
COMPLIANCE FOR INTENSITY AND FREQUENCY.
ADA
ADJ.
A.F.F.
CLG.
C.J.
COL.
CONC.
CONT.
DIM.
DWG.
EA
ELEC.
EQ.
EQUIP.
EXT'G.
F.E.
FIN.
FLR.
G.C.
GWB
H.M.
HT.
HVAC
INT.
LAM.
AMERICANS WITH DISIBILITIES ACT
ADJACENT
ABOVE FINISHED FLOOR
CEILING
CONTROL JOINT
COLUMN
CONCRETE
CONTINUOUS
DIMENSION
DRAWING
EACH
ELECTRIC
EQUAL
EQUIPMENT
EXISTING
FIRE EXTINGUISHER
FINISH
FLOOR
GENERAL CONTRACTOR
GYPSUM WALLBOARD
HOLLOW METAL
HEIGHT
HEATING/VENT./AIR CONDITIONING
INTERIOR
LAMINATE
LOC.
MEP
MECH.
MTL.
MISC.
N.I.C.
N.T.S.
NO.
O.C.
PL.
RM.
R.O.
SHLV
SIM.
STL
STRL.
TME.
T.O.W.
TYP.
U.L.
U.N.O.
VERT
W/
WD
LOCATION
MECHANICAL ELECTRICAL PLUMBING
MECHANICAL
METAL
MISCELLANEOUS
NOT IN CONTRACT
NOT TO SCALE
NUMBER
ON CENTER
PLASTIC
ROOM
ROUGH OPENING
SHELVES
SIMILAR
STEEL
STRUCTURAL
TO MATCH EXISTING
TOP OF WALL
TYPICAL
UNDERWRITERS LABORITORIES
UNLESS NOTED OTHERWISE
VERTICAL
WITH
WOOD
REG NO:
Nextore project
Number
73052
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
Date
RESPONSIBILITY
SCHEDULE/
ABBREVIATIONS
07-01-16
Drawn By
LLB
Checked By
ANP
Sheet
G002
PART 1 - GENERAL
A.
DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE COMPLIMENTARY. SPECIFIC INFORMATION MAY BE
FOUND IN EITHER OR BOTH.
B.
BIDDING CONTRACTORS SHALL INCLUDE ALL LABOR, MATERIALS, SCAFFOLDING, CRANES, EQUIPMENT
FASTENERS ETC. NECESSARY FOR COMPLETION AND FINAL COMPLETE TURNOVER OF AN OPERATIONAL RETAIL
FACILITY.
C.
D.
E.
F.
G.
THE TENANT HAS INDICATED AN INTENTION TO USE AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT A-107
"GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" AS PART OF THE CONTRACT DOCUMENTS
FOR THIS WORK.
ALL PERSONS INTENDING TO PROVIDE GOODS OR SERVICES IN CONNECTION w/THE WORK ARE ADVISED TO
READ AND UNDERSTAND THE APPLICABLE ADA DOCUMENTS PRIOR TO PROCEEDING.
THE TENANT HAS AWARDED SEPARATE CONTRACTS FOR SOME CONSTRUCTION WORK THAT WILL BE
CONDUCTED SIMULTANEOUSLY WITH WORK UNDER THIS CONTRACT. GENERAL CONTRACTOR MUST
COOPERATE WITH ALL OTHER CONTRACTORS SO THAT WORK UNDER THOSE CONTRACTS MAY BE CARRIED
OUT SMOOTHLY, WITHOUT INTERFERING WITH, OR DELAYING WORK UNDER THIS CONTRACT.
PRIOR TO START OF CONSTRUCTION, GENERAL CONTRACTOR SHALL ARRANGE A MEETING WITH LANDLORD'S
CONSTRUCTION REPRESENTATIVE TO REVIEW AND ESTABLISH ALL LANDLORD REQUIREMENTS. THIS INCLUDES,
BUT IS NOT LIMITED TO, THE FOLLOWING: ALL CONSTRUCTION, SCHEDULES, WORKMAN PARKING, DELIVERY
AND STORAGE OF MATERIALS, SAFETY PROTECTION, TRASH REMOVAL, SECURITY, AND DOCUMENTS REQUIRED
FOR FINAL LANDLORD SIGN-OFFS. GENERAL CONTRACTOR IS TO NOTIFY TENANT'S CONSTRUCTION MANAGER
IMMEDIATELY OF ANY ITEM THAT MAY AFFECT THE DESIGN INTENT OF THE DRAWINGS, OR RESULT.
ANY ITEMS DIRECTED BY LANDLORD, INSPECTORS, OR ANY OTHER AUTHORITY THAT AFFECTS THE DESIGN
INTENT OF THE DRAWINGS, OR RESULTS IN ADDITIONAL COSTS OR SCHEDULE DELAYS SHOULD NOT BE
PERFORMED UNTIL RECEIPT OF APPROVAL BY TENANT'S CONSTRUCTION MANAGER. ALL CHANGES MUST
IMMEDIATELY BE SUBMITTED IN WRITING TO TENANT'S CONSTRUCTION MANAGER FOR REVIEW. SUBMISSION
SHALL INCLUDE A GENERAL DESCRIPTION OF THE WORK REQUESTED, SIGNED BY THE REQUESTING
AUTHORITY. IN ADDITION, SUBMISSION MUST INCLUDE A COST BREAKDOWN AND THE IMPACT TO THE
CONSTRUCTION SCHEDULE.
01005 CONTRACTORS USE OF THE PREMISES.
PART 1 - GENERAL
A.
THE GENERAL CONTRACTOR AND ALL CONTRACTORS BIDDING ON THIS PROJECT SHALL VISIT THE JOB SITE TO
FAMILIARIZE THEMSELVES WITH ACTUAL JOB CONDITIONS AND TO CHECK FOR ANY INTERFERENCE BETWEEN
THEIR WORK AND THAT OF OTHER TRADES AND/OR APPARENT VIOLATIONS OF LOCAL, STATE, OR FEDERAL
CODES, LAWS, ORDINANCES, AND REGULATIONS BEFORE ENTERING INTO A CONTRACT WITH EITHER THE
GENERAL CONTRACTOR AND/OR TENANT.
1. ALL ITEMS SHALL BE INCLUDED IN THE BASE BID TO ACHIEVE THE FINAL PRODUCT INDICATED IN
DRAWINGS. THIS INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING: CONCRETE FLOOR PREP, FLOOR
SLAB X-RAYING, DEMISING WALL GYPSUM BOARD EXTENT AND CONDITION, REQUIRED FIRE PROOFING,
ELECTRICAL PANELS, ELECTRICAL, WATER, SEWER, VENTS AND TELEPHONE CONDUITS, ANY LANDLORD
REQUIRED FIRE PROTECTION SYSTEM OR TIE-INS TO BLDG. MANAGEMENT SYSTEMS, FIRE EXTINGUISHERS,
AND STRUCTURAL REQUIREMENTS FOR TENANT'S EQUIPMENT.
2. GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AND TENANT IN WRITING BEFORE ENTERING INTO
A CONTRACT WITH THE TENANT IF ANY INTERFERENCE OR VIOLATIONS APPEAR AND DEPARTURE FROM
THE DESIGN INTENT OF THE DOCUMENTS IS REQUIRED.
3. FAILURE TO PROVIDE ARCHITECT AND TENANT'S CONSTRUCTION MANAGER WITH THE
AFOREMENTIONED NOTIFICATION SHALL RESULT IN THE GENERAL CONTRACTOR BEING HELD
RESPONSIBLE TO COMPLETE ALL WORK REQUIRED TO MEET THE DESIGN INTENT OF THE CONTRACT
DOCUMENTS AT HIS/HER OWN COSTS WITH NO ADDITIONAL EXPENSES (EXTRAS) BEING INCURRED BY
THE TENANT. EXTRAS WILL NOT BE ALLOWED FOR JOB SITE CONDITIONS THAT WERE READILY VISIBLE OR
DETERMINED.
4. ALL SUB TRADES SHALL COORDINATE THEIR WORK WITH THE WORK OF OTHERS OR WITH EXISTING
CONDITIONS OCCURRING ABOVE OR BELOW THE LEASED PREMISES AND SHALL MAKE CHANGES FROM
TIME TO TIME AS REQUESTED TO ACCOMMODATE SUCH WORK OR CONDITIONS AT NO CHARGE TO
TENANT.
5.
CONTRACTORS SIGNS OR SIGNS OF ANY KIND MAY NOT BE DISPLAYED ON BARRICADES
6. THE G.C. SHALL BUILD ON SITE A TEMPORARY LOCKABLE STORAGE AREA. G.C. SHALL ACCEPT ALL TENANT
SUPPLIED ITEMS AND STORE THEM SAFELY IN SUCH SPACE.
B.
01400 QUALITY/GUARANTEE
B.
PART 1 - GENERAL
C.
VERIFY GRADIENT AND ELEVATIONS OF BASE ARE CORRECT. THICKNESS AND REINFORCING AS SHOWN ON
DRAWINGS.
D.
IMMEDIATELY AFTER PLACEMENT, PROTECT PAVEMENT FROM MECHANICAL INJURY.
2. 16 GAUGE AND HEAVIER COMPONENTS: FABRICATE COMPONENTS OF STRUCTURAL QUALITY STEEL
SHEET, ASTM A446 FOR GALVANIZED FINISH WITH A MINIMUM YIELD POINT OF 50,000 PSI.
E.
DEPOSIT CONCRETE WITHIN ANY ONE SECTION CONTINUOUSLY SO THAT NO CONCRETE WILL BE PLACED ON
OLDER CONCRETE WHICH HAS SET SUFFICIENTLY TO RESULT IN SEAMS AND PLANES OF WEAKNESS WITHIN
SECTION.
3. METAL STUDS: AISI "C" TYPE STRUCTURAL STUDS; SIZES, GAUGES AND SPACINGS SHOWN OR REQUIRED
IF NOT SHOWN; WITH 1-5/8" (41MM) MINIMUM FLANGE WIDTH, 1/2" (13MM) MINIMUM RETURNS AND
PRE-PUNCHED HOLES FOR UTILITY INSTALLATION.
PLACE SLABS FOR FULL THICKNESS IN ONE OPERATION, WITHOUT CHANGES IN PROPERTIES; SCREED TO
PROPER ELEVATION; FLOAT AND LIGHTLY TROWEL. UNLESS OTHERWISE SPECIFIED, WHEN CONCRETE HAS SET
SUFFICIENTLY TO RING UNDER TROWEL, GIVE SLAB SECOND TROWELING TO PRODUCE SMOOTH, DENSE
SURFACE. DUSTING OF SURFACES WITH CEMENT IS PROHIBITED. % OPTIMUM DENSITY. PROVIDE MIN. 6"
COMPACTED
a. 18-22 GAUGE (0.05" / 1.2MM - 0.03" / 0.8MM): ASTM A446/A446M GRADE A; MINIMUM YIELD STRESS
OF 33 KSI (228 MPA).
A.
B.
A.
A.
A.
A.
B.
C.
03732 CONCRETE REPAIR
D.
C.
FLOOR LEVELER CONCRETE TO BE INSTALLED AT LOW AREAS, HOLES AND DEPRESSIONS. PATCH CRACKS AND
BROKEN CONCRETE WITH FLOOR PATCH TROWELED SMOOTH IN ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS AND LANDLORD SPECIFICATIONS. UNDERLAYMENT COMPOUND TO BE FREE FLOWING,
SELF-LEVELING, PUMPABLE, AND CEMENT-BASED FOR APPLICATIONS FROM ONE INCH THICK TO FEATHERED
EDGES.
A.
B.
ALL PROJECT COORDINATION SHALL BE THROUGH TENANT'S CONSTRUCTION MANAGER AS LISTED ON TITLE
SHEET.
COMPLY WITH CONSTRUCTION MANAGER'S PROCEDURES FOR INTRA-PROJECT COMMUNICATIONS;
SUBMITTALS, REPORTS AND RECORDS, SCHEDULES, COORDINATION DRAWINGS, RECOMMENDATIONS; AND
RESOLUTION OF AMBIGUITIES AND CONFLICTS, INCLUDING REQUESTS FOR SUBSTITUTIONS AND CHANGE
ORDERS.
A.
B.
PAYMENT SCHEDULE FOR PROJECT WILL BE ON A MONTHLY SUBMITTAL OF AIA DOCUMENT #G702 AND
#G703 "APPLICATION AND CERTIFICATE FOR PAYMENT" UNLESS OTHERWISE REQUESTED BY TENANT.
C.
CONTRACT SHALL BE AIA DOCUMENT #A107 "STANDARD FORM OF AGREEMENT BETWEEN OWNER AND
CONTRACTOR".
1)
CONCRETE REPAIR
3. DEMOLITION INCLUDES REMOVAL OF THE EXISTING INTERIORS, IF REQUIRED, BUT NOT LIMITED TO
INTERIOR PARTITIONS, CABINETS, SUSPENDED CEILING TILE, ELECTRICAL, MECHANICAL, ETC., AS REQUIRED,
AS SHOWN OR AS DIRECTED.
4. ALL ITEMS INDICATED OR REQUIRED TO BE DEMOLISHED OR REMOVED TO BE LEGALLY DISPOSED OF IN
COORDINATION AND COMPLIANCE WITH ALL LANDLORD PROCEDURES AND REGULATIONS.
5. ALL ITEMS INDICATED TO BE RELOCATED OR REINSTALLED TO BE CLEANED, SERVICED AND PREPARED FOR
PROPER RE-USE. ANY ITEMS STORED DURING CONSTRUCTION ARE TO BE PROTECTED TO AVOID DAMAGE
OR THEFT
6. ALL ITEMS INDICATED AS EXISTING TO REMAIN , SHALL BE CLEANED, SERVICED AND PREPARED FOR
PROPER CONTINUED RE-USE. PROTECT ALL ITEMS SUFFICIENTLY DURING CONSTRUCTION TO AVOID
DAMAGE OR THEFT.
7. COOPERATE AND COORDINATE WITH LANDLORD, THE TENANTS OF THE ADJACENT SPACES AND THE
TENANT, IN SCHEDULING WORK IN ORDER TO CAUSE THE LEAST INCONVENIENCE TO PERSONNEL AND
PROPERTY.
i. LUMBER, 2 INCHES AND LESS IN THICKNESS: 19 PERCENT.
3. THOROUGHLY CLEAN FLOOR SLAB REMOVING CONDITIONS THAT WILL AFFECT BOND
RESIDUE FROM REMOVAL OF ADHESIVES, UNDERLAYMENTS, STAINS, OILS, ETC.
ii. PLYWOOD: 15 PERCENT
INCLUDING
b) FLAME SPREAD: FIRE RETARDANT TREATED MATERIALS TO HAVE FLAME SPREAD RATING OF 25
OR LESS IN A 30 MINUTE TEST WITH NO EVIDENCE OF SIGNIFICANT PROGRESSIVE
COMBUSTION, ASTM E 84, ADDITIONALLY, FLAME FRONT NOT TO PROGRESS MORE THAN 10
1/2 FEET BEYOND CENTER LINE OF BURNER AT ANY TIME.
c) SMOKE DEVELOPED: INTERIOR FINISH AND TRIM MATERIALS, WHERE SPECIFIED, TO HAVE FIRE
RETARDANT TREATMENT CONFORMING TO ABOVE REQUIREMENTS FOR "FLAME SPREAD" PLUS
SMOKE DEVELOPED RATING OF 25 OR LESS, ASTM E 84.
B.
C.
D.
E.
THE CONTRACTOR SHALL REMOVE, REPAIR, RESTORE, AND REPLACE WHERE ANY SUCH WORK IS NECESSARY
OR AS INDICATED ON THE DRAWINGS. CUT ALL NECESSARY OPENINGS, AND PATCH/REPAIR/SEAL SAME TO
DEGREE NECESSARY TO SATISFY ALL REQUIREMENTS. INSOFAR AS POSSIBLE, ALL PROTRUSIONS, MARKS,
CRACKS OR OTHER EVIDENCE OF A DEFICIENT OR DAMAGED CONDITION SHALL BE ELIMINATED, UNLESS
SPECIFICALLY NOTED OTHERWISE. ANY PARTS WHICH ARE SPLIT, CRACKED, CHIPPED, SPALLED, BROKEN,
MISSING, OR OUT OF LINE OR ADJUSTMENT, MECHANICALLY OR STRUCTURALLY UNSAFE OR UNSOUND, BENT,
TORN OR OTHERWISE DEFICIENT OR INJURED IN ANY MANNER, SHALL BE REMOVED, REPLACED, RESTORED OR
REPAIRED. LANDLORD'S REPRESENTATIVE, ARCHITECT, AND TENANT'S CONSTRUCTION MANAGER MUST BE
NOTIFIED IMMEDIATELY OF ANY STRUCTURAL OR SAFETY DEFECTS, AND ONLY THE TENANT'S CONSTRUCTION
MANAGER IF THE DEFECT(S) ARE LIMITED TO COSMETIC FINISHES.
EXERCISE EXTREME CARE DURING DEMOLITION SO AS NOT TO DAMAGE OR DISRUPT ANYUTILITY OR
SPRINKLER LINES WHICH MIGHT PASS THROUGH THIS SPACE TO SERVICE OTHER MALL SPACES OR TENANTS.
GENERAL CONTRACTOR WILL BEAR SOLE RESPONSIBILITY OF ANY SUCH DISRUPTION OR DAMAGE.
ALL ABANDONED ELECTRICAL AND TELEPHONE CONDUIT, PLUMBING LINES, DRAIN LINES, AND ALL
MECHANICAL ITEMS SHALL BE CAPPED AT SOURCE AND REMOVED IN A MANNER TO MEET ALL LANDLORD
AND CODE REQUIREMENTS, UNLESS DIRECTED OTHERWISE.
3. GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING, REPAIRING AND LEVELING OF THE EXISTING
FLOOR SLAB, REPAIR OF DEMISING WALLS AND ROOF DECK AFTER COMPLETION OF ALL DEMOLITION
AND PRIOR TO THE COMMENCEMENT OF NEW CONSTRUCTION.COORDINATE WITH LANDLORD
RESPONSIBILITY IN PERFORMING ANY AND ALL ROOF WORK.
NO WORK UNDER THIS SECTION
A.
DIVISION 05000 - METALS
05120 STRUCTURAL STEEL
PART 1 - GENERAL
REINFORCEMENT (PER LANDLORD REQUIREMENTS)
E.
BONDING AGENT (IF REQUIRED)
F.
VAPOR BARRIER
PROVIDE 14 GA. REINFORCEMENT AT CLOSER AND LOCKS AND 8 GA. REINFORCEMENT AT HINGES.
FRAME - 12 GA. COLD ROLLED STEEL, ARC WELDED AT CORNERS AND GROUND SMOOTH AS MANUFACTURED BY
STEELCRAFT OR EQUAL. FRAMES TO BE PHOSPHATIZED AND RECEIVE ONE COAT BAKED ON PRIMER READY TO RECEIVE
PAINT.
a. PROVIDE 14 GA. REINFORCEMENT AT CLOSER AND LOCKS AND 8 GA. REINFORCEMENT AT HINGES.
PART 2 - PREPARATION / EXECUTION
A.
INSTALL FRAMES IN ACCORDANCE WITH SDI-100.
B.
COORDINATE WITH MASONRY WALL CONSTRUCTION FOR ANCHOR PLACEMENT.
C.
COORDINATE INSTALLATION OF FRAMES WITH INSTALLATION OF HARDWARE SPECIFIED IN DOOR SCHEDULE.
1. FOLLOW DOOR HARDWARE INSTITUTE (DHI) GUIDELINES.
PART 1 - GENERAL
A.
THIS SECTION INCLUDES ALL ALUMINUM/GLASS DOORS, DOOR HARDWARE SPECIFICALLY SUPPLIED BY DOOR MANUFACTURER,
EXTRUDED ALUMINUM GLAZING FRAMES COMPLETE WITH ACCESSORIES AND GLASS AS DETAILED ON THE DRAWINGS AND
RESPONSIBILITY SCHEDULE.
1. ALUMINUM/TEMPERED GLASS ENTRANCE DOORS SHALL BE KAWNEER (SEE PARAGRAPH 2 OF THIS SECTION) SERIES 350
(SIZES OF VERTICAL STILE AND TOP RAIL AS PER PLANS AND DETAILS) SINGLE ACTING WITH 1/2" TEMPERED GLASS INFILL
SET WITH ELASTOMERIC GASKETS.
CLIENT COMMENTS
COORDINATE PARAPET AND FLASHING NAILER INSTALLATION WITH INSTALLATION OF ROOFING. SEE SECTION
01005, E, "ROOF CUTTING AND PATCHING".
C.
INSTALL TELEPHONE AND ELECTRICAL PANEL BACK BOARDS WITH PLYWOOD SHEATHING MATERIAL WHERE
REQUIRED. SIZE THE BACK BOARD BY 12 INCHES BEYOND SIZE OF ELECTRICAL PANEL.
HINGING
- TOP PATCH AND BOTTOM PIVOTS
CLOSERS
- NORTON SERIES 1600 - ONE PER DOOR LEAF
LOCKS
- DEADLOCK: "BEST CORE"
b. MANUFACTURERS: KAWNEER COMPANY, INC. , NORCROSS, GA UNITED STATES ALUMINUM CORP., ROCK HILL SC
c. FINAL FINISHES MUST MATCH EXACTLY. COLORS TO BE AS SPECIFIED ON FINISH SCHEDULE.
B.
ALUMINUM GLAZING FRAME.
1. KAWNEER (SEE PARAGRAPH 3 OF THIS SECTION) TRIFAB II 451 SERIES, (MULLION, RAIL, POST AND BASE SIZES AS PER
PLANS AND DETAILS) FOR INFILL WITH 1/2" CLEAR TEMPERED GLASS.
FOLLOW AWI (ARCHITECTURAL WOODWORK INSTITUTE) ARCHITECTURAL WOODWORK QUALITY STANDARDS.
B.
MILLWORK AND CABINETRY MAY BE SHOP OR FIELD ASSEMBLED AT CONTRACTORS OPTION.
B.
INSTALL PER MANUFACTURER'S RECOMMENDATIONS AND PROCEDURES.
C.
INSTALL ITEMS IN A RIGID, STRAIGHT, PLUMB, LEVEL MANNER ACCURATELY FITTED AND SCRIBED TO ABUTTING SURFACES.
C.
ALL JOINTS BETWEEN FRAMING AND BUILDING STRUCTURE SHALL BE SEALED TO PROVIDE WATERTIGHT INSTALLATION.
D.
INSTALL SEALANT AND BACKING MATERIALS AT PERIMETER OF FRAME.
COUNTERSINK NAILS AND SCREW HEADS AND PATCH AND SAND SMOOTH.
F.
SHOP DRAWINGS: SUBMIT SHOP DRAWINGS TO ARCHITECT INDICATING SHOP AND ERECTION DETAILS,
INCLUDING CUTS, CONNECTIONS, HOLES, THREADED FASTENERS AND WELDS.
F.
FINISH WOODWORK SHALL BE DRESSED AND SANDED, FREE FROM MACHINE AND TOOL MARKS, ABRASIONS, RAISED GRAIN
OR OTHER DEFECTS.
G.
PRE-ASSEMBLE ITEMS IN SHOP TO GREATEST POSSIBLE EXTENT TO MINIMIZE FIELD SPLICING AND ASSEMBLY.
DISASSEMBLE UNITS ONLY AS NECESSARY FOR SHIPPING AND HANDLING LIMITATIONS. CLEARLY MARK UNITS
FOR RE-ASSEMBLY AND COORDINATE INSTALLATION.
G.
PROTECT FINISHED WORK UNTIL ACCEPTANCE BY TENANT.
H.
WELDING PROCEDURES, WELDERS, WELDING OPERATIONS AND TACKERS SHALL BE QUALIFIED
ACCORDANCE WITH AWS-D1.1- "STRUCTURAL WELDING CODE".
I.
FABRICATOR SHALL BE A MEMBER OF AMERICAN INSTITUTE OF STEEL CONSTRUCTION.
A.
J.
FABRICATE STRUCTURAL STEEL IN ACCORDANCE WITH AISC "SPECIFICATIONS FOR DESIGN, FABRICATION AND
ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" AND "CODE OF STANDARD PRACTICE".
PART 2 - PREPARATION / EXECUTION
2. WHERE FASTENING SPACINGS OR SIZES ARE NOT SHOWN, CONTRACTOR SHALL USE SPACINGS AND SIZES
OF BOLTS, SCREWS, WELDS, ETC., WHICH WILL DEVELOP THE FULL STRENGTH OF THE MEMBERS BEING
FASTENED. THUS FAILURE DUE TO OVER-STRESSING MUST OCCUR IN THE MEMBERS BEFORE OCCURRING
IN THE FASTENINGS.
PART 2 - PREPARATION / EXECUTION
A. PRE-ASSEMBLE ITEMS IN SHOP TO GREATEST POSSIBLE EXTENT TO MINIMIZE FIELD SPLICING AND ASSEMBLY.
DISASSEMBLE UNITS ONLY AS NECESSARY FOR SHIPPING AND HANDLING LIMITATIONS. CLEARLY MARK UNITS
FOR RE-ASSEMBLY AND COORDINATE INSTALLATION.
06424 LAMINATES
PART 1 - GENERAL
B.
SEE DOOR SCHEDULE FOR SPECIFIC ITEMS, MANUFACTURERS AND MODEL NUMBERS.
C.
FOLLOW DHI (DOOR AND HARDWARE INSTITUTE) STANDARDS AND GUIDELINES AND AWI (AMERICAN WOODWORKING
INSTITUTE) STANDARDS FOR HARDWARE INSTALLED ON WOOD DOORS.
D.
FIRE RATED HARDWARE SHALL FOLLOW GUIDELINES AS ESTABLISHED BY:
3. NFPA 252 - FIRE TESTS OF DOOR ASSEMBLIES.
4. UL 10B - SAFETY FIRE TESTS OF DOOR ASSEMBLIES.
B.
SEE MILLWORK SECTION FOR TYPICAL NOTES AND REFERENCES.
5. UL 305 - SAFETY PANIC HARDWARE.
E.
FURNISH OWNER WITH MAINTENANCE DATA, MAINTENANCE PROCEDURES, MANUFACTURERS WARRANTIES AND SPECIAL
TOOLS.
F.
FINISHES: AS NOTED ON PLANS AND SCHEDULES.
G.
KEYING
2. GENERAL CONTRACTOR TO INSTALL CONSTRUCTION CORES DURING CONSTRUCTION AND REPLACE WITH PERMANENT
AT END OF JOB PRIOR TO TURN-OVER.
PART 1 - GENERAL
BATT INSULATION
H.
SEE SECTION ON ALUMINUM ENTRANCES FOR HARDWARE SPECIFIC TO THOSE DOORS
I.
MANUFACTURERS:
1. HINGES: STANLEY FBB 179 AVERAGE FREQUENCY, OR EQUAL. EXTERIOR DOORS TO RECEIVE TAMPERPROOF BUTTS
AND/OR LATCH GUARDS.
2. STRUCTURAL STEEL TUBING: FY 46 KSI COLD-FORMED TUBING EXCEPT ROUND, ASTM A500-68, GRADE B.
1. FURNISH AND INSTALL 3 1/2" MIN. THERMAL BATT TYPE INSULATION AT EXTERIOR WALLS OR AS SOUND ATTENUATION
BLANKET WHERE SHOWN AND AS SPECIFIED ON DRAWINGS.
3. STEEL PIPE: ASTM A53, GRADE B.
2. EXTEND FROM FLOOR TIGHT TO ROOF DECK ABOVE.
2. LOCKSETS/LATCHES: SCHLAGE D-SERIES, SPARTA DESIGN w/ROSE, OR EQUAL. LOCKSETS TO RECEIVE INTERCHANGEABLE
CORE CYLINDERS TO ACCEPT "BEST CORE". SEE KEYING NOTES THIS SECTION.
3. FURNISH AND INSTALL .004 MIL. VISQUEEN VAPOR BARRIER AT EXTERIOR WALLS ON WARM SIDE OF STUDS.
3. CLOSERS: NORTON - POWER ADJUSTABLE CLOSER FOR BARRIER FREE OPERATION. SERIES 8301 BF OR EQUAL.
4. ANCHOR BOLT: CONFORM TO ASTM A307.
5. WELDING ELECTRODES: ASTM A233, E-70 OR BETTER.
C.
6. HIGH STRENGTH THREADED FASTENERS: ASTM A325 OR A-490.
7. METAL STUDS: SIZE ACCORDING TO CONSTRUCTION DOCUMENTS x 20 GAUGE STEEL AT 16" O.C. TRACKS
TO BE ANCHORED BY MEDIUM POWER ACTUATED FASTENERS @ 24" O.C.
8. EXTERIOR / INTERIOR METAL STUDS: SIZE ACCORDING TO CONSTRUCTION DOCUMENTS X 25 GAUGE AT
16" O.C..
9. SHOP PAINT PRIMER: STANDARD PRIMER:
D.
GENERAL CONTRACTOR TO PROVIDE AND INSTALL WATERPROOFING MEMBRANE OVER ENTIRE FLOOR OF REST ROOMS
BELOW FINISH FLOORING AND UP WALL A MIN. 4". (ONLY WHERE REST ROOMS ARE LOCATED ABOVE ANOTHER FLOOR.)
APPLY PER MANUFACTURERS INSTRUCTIONS AND CAULK AS REQ'D. TO MATCH ADJACENT FINISHES.
G.C. SHALL SLEEVE, FIRESTOP, FLASH AND CAULK ALL PENETRATIONS OF FLOORS SO THAT ODORS OR LIQUIDS WILL NOT
PENETRATE THE SLAB AT THESE OPENINGS. SUCH SLEEVES SHALL BE INSTALLED ACCORDING TO THE LANDLORD STANDARD
DETAILS
07900 JOINT SEALERS / CAULKING
a. SSPC PAINT 15
PART 1 - GENERAL
b. TNEMEC 1009 GRAY METAL PRIMER
A.
c. MARTIN-SENOUR CO. #664 RED OXIDE ZINC CHROMATE PRIMER
PROVIDE AND INSTALL EXPANSION JOINT MATERIAL, SEALANTS AND JOINT BACKING FOR JOINTS BETWEEN DISSIMILAR
MATERIALS.
1. SILICONE SEALANTS (TYPE S): ASTM C920, SINGLE COMPONENT, NON-SAGGING, NON-STAINING, NON-BLEEDING; FOR
USE AS GENERAL CAULKING. COLOR TO MATCH ADJACENT SURFACES. MANUFACTURER BY GE SILICONES OR EQUAL.2.
JOINT BACKING: ROUND, OPEN CELL POLYETHYLENE FOAM ROD.
d. PRATT AND LAMBERT NOXIDE 107, ONE DAY PRIMER-GRAY. E. STEEL SHALL BE CLEAN AND FREE
FROM OIL, DIRT, LOOSE MILL SCALE AND ANY OTHER SUBSTANCE THAT WOULD IMPAIR WELDING,
PERFORMANCE OF FRICTION-TYPE BOLTED.
Seal
1. GENERAL CONTRACTOR TO COORDINATE KEYING AND MASTER KEYING WITH CONSTRUCTION MANAGER.
07200 INSULATION AND WATERPROOFING
B.
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
1. NFPA 80 - FIRE DOORS AND WINDOWS.
FOLLOW MANUFACTURERS GUIDELINES AND RECOMMENDATIONS FOR ADHESIVE AND SUBSTRATE PREPARATION.
FOR INSULATION REQUIRED AT DUCKWORK, PLUMBING LINES, ETC. SEE MECHANICAL / ELECTRICAL SPECIFICATIONS AND
DRAWINGS.
20474
08710 DOOR HARDWARE
A.
A.
REG NO:
VERIFY DIMENSIONS, TOLERANCES AND ATTACHMENTS AND SHIMS TO PERMIT SUFFICIENT ADJUSTMENTS TO
ACCOMMODATE IRREGULARITIES.
2. NFPA 101 - LIFE SAFETY CODE.
DIVISION 07000 - THERMAL AND MOISTURE PROTECTION
07-01-16
PART 1 - GENERAL
A. FURNISH AND INSTALL FINISH HARDWARE FOR INTERIOR AND EXTERIOR DOORS, ROLLING GRILLES AND WINDOWS.
INSTALL HIGH PRESSURE LAMINATES AS SPECIFIED IN FINISH SCHEDULE AND AS DETAILED IN DRAWINGS.
END OF DIVISION
DATE:
Engineer
A.
CUTTING AND REPAIRING OF THIS WORK FOR ACCOMMODATION OF WORK BY OTHERS SHALL BE DONE AS PART OF
MILLWORK RESPONSIBILITY.
GLENN S. YEAKEL
EXTERIOR - 1/2" CLEAR INSULATED GLASS FOR INFILL INTO GLAZING FRAME.
PART 2 - PREPARATION / EXECUTION
E.
1. UNLESS OTHERWISE SHOWN, FABRICATOR SHALL DESIGN / DETAIL CONNECTIONS IN CONFORMANCE
WITH AISC STANDARD FOR FORCES AND MOMENTS SHOWN.
1.
DO NOT DELIVER OR INSTALL ITEMS UNTIL BUILDING AND ROOMS RECEIVING SUCH ARE COMPLETED AND THOROUGHLY DRY
AND FREE OF EXCESSIVE MOISTURE.
D.
NAME:
GLAZING
A.
VERIFY THE EXACT SIZE AND LOCATION OF ALL OPENINGS PRIOR TO FABRICATION OF STEEL FRAMING
MEMBERS.
IN
C.
PART 2 - PREPARATION / EXECUTION
E.
Seal
THRESHOLD - MILL FINISH ALUMINUM MAXIMUM 1/2" HIGH
C.
PROVIDE OPENINGS AND SPECIAL FRAMING REQUIRED BY OTHER TRADES. MECHANICAL FRAMING LOADS,
OPENINGS, AND STRUCTURE RELATED TO MECHANICAL REQUIREMENTS ARE SHOWN FOR BIDDING PURPOSES
ONLY. CONTRACTOR SHALL OBTAIN WRITTEN SIGN-OFF FROM MECHANICAL AND OTHER TRADES FOR
SPECIFIC REQUIREMENTS BEFORE PROCEEDING WITH SUCH WORK. ARCHITECT'S OR ENGINEER'S APPROVAL OF
ERECTION AND SHOP DRAWINGS SHALL NOT RELIEVE CONTRACTOR FROM THIS RESPONSIBILITY.
2016-026A
PUSH/PULL - KAWNEER "F-2"
SET MEMBERS LEVEL AND PLUMB, IN CORRECT POSITION.
B.
281 Farmington Avenue
Farmington, CT. 06032
a. HARDWARE - TO INSURE SINGLE SOURCE RESPONSIBILITY, THE FOLLOWING SHALL BE PROVIDED AND INSTALLED
BY THE DOOR SUPPLIER / INSTALLER
SEE DRAWINGS AND RESPONSIBILITY SCHEDULE FOR DETAILS, SIZES, DIMENSIONS.
SHOP CONNECTIONS SHALL BE WELDED.
07/19/16
ASSOCIATES INC.
08400 ALUMINUM ENTRANCES AND STOREFRONTS
B.
FIELD CONNECTIONS: HIGH STRENGTH FASTENERS SHALL BE USED FOR BOLTED CONNECTIONS.
Description
SUBMIT FOR PERMIT
Architect of Record
b. INSTALL MINIMUM THREE (3) JAMB ANCHORS AND BASE ANCHORS EACH SIDE.
THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE PROJECT IS FULLY COMPLETED.
IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND
TO INSURE STABILITY OF THE BUILDING AND ITS COMPONENT PARTS AND ADEQUACY OF TEMPORARY
SUPPORT DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER TEMPORARY BRACING, GUY OR
TIE DOWNS MIGHT BE NECESSARY. SUCH MATERIAL IS NOT SHOWN ON DRAWINGS. IF APPLIED, THEY SHALL
BE REMOVED AS CONDITIONS PERMIT AND SHALL REMAIN CONTRACTOR'S PROPERTY.
NAME:
DATE:
4. THRESHOLDS, SWEEPS AND WEATHER STRIPPING:
THERMAL BARRIER SADDLE THRESHOLD - PEMKO #252X2AFG, MAXIMUM HEIGHT 1/2", OR EQUAL.
DOOR BOTTOM SWEEP
- PEMKO #315CN, OR EQUAL.
REG NO:
RIGID JAMB WEATHERSTRIP - PEMKO #303AV, OR EQUAL.
5. STOPS, KICKPLATES AND SILENCER;
WALL STOP
-
IVES #407, OR EQUAL
FLOOR STOP
-
IVES #436, OR EQUAL
DOOR SILENCER -
Nextore project
Number
73052
IVES #20, OR EQUAL
KICKPLATE
- IVES #8400, 8" HIGH X FULL WIDTH OF DOOR, OR EQUAL SCREW TO MATCH KICKPLATE.
ONE-WAY VIEWER (PEEP) - IVES #696, OR EQUAL.
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
PART 2 - PREPARATION / EXECUTION
05400 METAL FRAMING
LIGHT GAUGE (COLD-FORMED) METAL FRAMING
A.
REMOVE LOOSE MATERIALS AND FOREIGN MATTER WHICH MIGHT IMPAIR ADHESION OF SEALANT.
B.
CLEAN AND PRIME JOINTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
C.
PROTECT ELEMENTS SURROUNDING THE WORK OF THIS SECTION FROM DAMAGE OR DISFIGURATION.
PART 1 - GENERAL
D.
INSTALL SEALANT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
A.
E.
INSTALL JOINT BACKING.
F.
APPLY SEALANT WITHIN RECOMMENDED APPLICATION TEMPERATURE RANGES. CONSULT MANUFACTURER WHEN SEALANT
CANNOT BE APPLIED WITHIN THESE TEMPERATURE RANGES.
FURNISH AND INSTALL A COMPLETE SYSTEM OF LIGHT GAUGE FRAMING MEMBERS FOR INTERIOR WALL
PARTITIONS AND CEILING SUSPENSION COMPONENTS.
1. SYSTEM TO INCLUDE ALL TOP AND BOTTOM RUNNERS, BRACES, CLIP ANGLES, ACCESSORIES, FASTENERS,
ETC. FOR EACH TYPE OF FRAMING AS SHOWN ON DRAWINGS.
a. INSTALL METAL FRAMING SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS AND RECOMMENDATIONS.
PART 2 - PREPARATION / EXECUTION
CONCRETE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR STRENGTH, CONSISTENCY PROPORTIONS
AND HANDLING OF CONCRETE.
SEE DOOR SCHEDULE FOR REQUIRED HARDWARE.
SEE STRUCTURAL DOCUMENTS FOR ADDITIONAL SPECIFICATIONS / STANDARDS.
1. SLAB ON GRADES TO RECEIVE 6 MIL. CLEAR OR BLACK POLYETHYLENE FILM WITH MINIMUMOF 12"
OVERLAP. TAPE ALL SEAMS.
A.
2.
a.
b.
C.
C.
1
By
1. DOORS THERMALLY INSULATED L-16 WITH POLYSTYRENE CORE (R=7.7): SDI-100 GRADE AS MANUFACTURED BY
STEELCRAFT, CINCINNATI, OHIO, OR EQUAL. FRAMES TO BE PHOSPHATIZED AND RECEIVE ONE COAT BAKED ON PRIMER
READY TO RECEIVE PAINT.
B.
B.
Date
07/07/16
PART 1 - GENERAL
A.
NON-RATED THERMALLY INSULATED STEEL DOORS AT EXTERIOR OPENINGS.
4. FINAL FINISH MUST MATCH EXACTLY COLORS AS SPECIFIED ON FINISH SCHEDULE, IF EXACT COLOR IS NOT AVAILABLE
THROUGH MANUFACTURER PAINT CONTRACTOR SHALL FIELD PAINT.
889 VALLEY PARK DRIVE
3. ASTM C881
COORDINATE INSTALLATION OF FRAMES WITH INSTALLATION OF DOORS AND HARDWARE AS SPECIFIED IN DOOR SCHEDULE
AND ON DRAWINGS.
FURNISH AND INSTALL FINISHED TRIM, CABINETRY, COUNTERS, DOORS, AND ALL FINISH ITEMS SUCH AS LAMINATES AND
FINISH DOOR HARDWARE, AS INDICATED AND DETAILED ON PLANS.
a. MANUFACTURER: CHEMTREX, INC.
2. CONSULT MANUFACTURER FOR APPLICATION PROCEDURE.
COORDINATE WITH WALL CONSTRUCTION FOR ANCHOR PLACEMENT.
C.
A.
1. "SONOBOND" EPOXY CONCRETE BONDING AGENT OR EQUAL
SHAKOPEE, MINNESOTA 55379-1854
B.
3. MANUFACTURERS: KAWNEER COMPANY, INC., NORCROSS, GA UNITED STATES ALUMINUM CORP., ROCK HILL, SC
D.
Revisions:
Mark
06210 MILLWORK AND FINISH CARPENTRY
CLASS 1 3000 PSI INTERIOR SLABS (OR MIN.REQUIRED PER
D.
PROVIDE 8 GA. REINFORCEMENT AT HINGES AND 14 GA. REINFORCEMENT AT LOCK AND CLOSERS.
INSTALL ADJUSTABLE JAMB ANCHOR 4" DOWN FROM HEAD AND WELDED-IN BASE ANCHOR AT EACH JAMB.
PART 1 - GENERAL
PROVIDE AND INSTALL CONCRETE AS INDICATED ON THE DRAWINGS.
CONCRETE STRENGTHS ARE AS FOLLOWS:
LANDLORD SPECIFICATIONS.)
a.
b.
PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY FOR COMPLETE INSTALLATION OF STEEL
FRAMING AND SUPPORT MEMBERS, ANGLES, PLATES, ANCHOR BOLTS REQUIRED FOR THE CONNECTION,
SETTING AND BEARING OF COMPLETE STRUCTURE AS SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN.
DIVISION 03000 - CONCRETE
03300 CAST-IN-PLACE CONCRETE
C.
SURFACES TO BE
2. PROVIDE AND INSTALL ALL INTERNAL SUPPORT FRAMING, RELATED FLASHINGS, ANCHORAGE AND ATTACHMENT
DEVICES.
END OF DIVISION
CONCRETE WORK SHALL CONFORM TO THE LATEST EDITION OF "AMERICAN CONCRETE INSTITUTE" CODES
AND STANDARDS INCLUDING ACI 301, ACI 315, AND ACI 318.
PROVIDE 8 GA. REINFORCEMENT AT HINGES, AND 14 GA. REINFORCEMENT AT LOCK AND CLOSERS.
3. TELEPHONE AND ELECTRICAL PANEL BACK BOARDS. PART 2 - PREPARATION / EXECUTION
1. STRUCTURAL STEEL FY 36 KSI STEEL, ASTM A36.
B.
SEE DOOR SCHEDULE FOR REQUIRED HARDWARE.
INSTALL FRAMES IN ACCORDANCE WITH SDI-100.
d. STORE TREATED MATERIALS FOR EASY IDENTIFICATION AND PROTECT FROM MOISTURE; PROVIDE
WELL VENTILATED DRY STORAGE.
DIVISION 04000 - MASONRY
GENERAL CONTRACTOR RESPONSIBILITIES
2. GENERAL CONTRACTOR IS TO ERECT CONSTRUCTION BARRICADES AND DEBRIS/DUCT SCREENS PER
LANDLORD'S SPECIFICATIONS. CONTACT LANDLORD'S REPRESENTATIVE PRIOR TO THE COMMENCEMENT
OF ALL DEMOLITION WORK.
a.
b.
2. FRAMES - 2" FRONT FACE - 16 GA. HOLLOW METAL WITH CONTINUOUSLY WELDED CORNERS.
PHOSPHATIZED AND RECEIVE ONE COAT BAKED ON PRIMER READY TO RECEIVE PAINT.
c. DELIVER TREATED MATERIALS BUNDLED AND MARKED TO IDENTIFY TREATMENT.
f. FIELD CUTS AND HOLES: FIELD-TREAT IN ACCORDANCE WITH AWPA M-4.
1. GENERAL CONTRACTOR IS TO NOTIFY TENANT IMMEDIATELY OF ANY SEVERE DISCREPANCIES OR
IRREGULARITIES DISCOVERED DURING DEMOLITION WHICH MIGHT AFFECT THE CURRENT STORE DESIGN.
GENERAL CONTRACTOR IS TO PAY SPECIAL ATTENTION TO AVAILABLE HEIGHT FOR INTENDED CEILING
ELEVATION, MECHANICAL DUCTWORK AND RECESSED LIGHTING.
A.
b. CERTIFICATES: FURNISH AFFIDAVIT IF REQUIRED BY CODE OFFICIAL STATING THAT MATERIALS HAVE
BEEN TREATED IN ACCORDANCE WITH SPECIFICATIONS AND THAT MOISTURE CONTENT, AFTER
TREATMENT, DOES NOT EXCEED SPECIFIED LIMITS; INCLUDE CHEMICAL USED AND RETENTION
OBTAINED FOR PRESSURE TREATED MATERIAL. INCLUDE THE "QUALITY MARK" OF ASSOCIATION
HAVING JURISDICTION OVER THE TREATMENT.
e. HANDLE TREATED MATERIALS IN ACCORDANCE WITH AWPA STANDARDS. IN ADDITION TO USED IN
TREATMENT, FURNISH ADDITIONAL MATERIAL FOR FIELD TREATMENT \ MATERIAL OF CUTS.
A.
Macy's Store Number: (687)
1. DOORS - 1 3/4" THICK FLUSH MOUNTED "TYPE B" AS MANUFACTURED BY STEELCRAFT. SURFACES TO BE PHOSPHATIZED
AND RECEIVE ONE COAT BAKED ON PRIMER READY TO RECEIVE PAINT.
AND IN
END OF DIVISION
8. SEE MECHANICAL AND ELECTRICAL PLANS FOR SPECIFIC DEMOLITION ITEMS UNDER THOSE TRADES.
PART 2 - PREPARATION / EXECUTION
A. ARRANGE WITH THE LANDLORD A CONVENIENT TIME TO PERFORM DEMOLITION WORK AND INSTALL
TEMPORARY PROTECTED MEANS OF EGRESS FROM REQUIRED EXITS. INCLUDE TEMPORARY LIGHTING AND
SAFETY DEVICES, ALL IN ACCORDANCE WITH GOVERNING STATE AND LOCAL CODES AND LAND-LORD
REQUIREMENTS.
INTERIOR HOLLOW METAL DOORS AND FRAMES FOR INSTALLATION AT DRYWALL AND METAL STUD PARTITIONS.
PERFORMANCE REQUIREMENTS:
2. REMOVE AND DISPOSE OF EXISTING FLOOR FINISHES WHERE INDICATED ON DEMOLITION PLAN.
9. CLEAN AREAS REMOVING ALL WASTE MATERIAL, BROOM CLEAN.
2. CONSULT DEMOLITION PLANS INCLUDED WITH PROJECT DOCUMENTS FOR ADDITIONAL NOTES AND SITE
SPECIFIC ITEMS.
D.
a) MOISTURE CONTENT: AFTER TREATMENT, THE MAXIMUM MOISTURE CONTENT OF WOOD
MATERIALS SHALL NOT EXCEED THE FOLLOWING:
8. TRENCH ONLY AT SLAB ON GRADE. VERIFY AND GET APPROVAL OF TRENCH OR CORE LOCATIONS WITH
THE LANDLORDS REPRESENTATIVE AND MALL STRUCTURE PRIOR TO COMPLETING ANY WORK. CORES TO
BE SEALED WATERPROOF. SEE SECT. 07200 "INSULATION AND WATERPROOFING" FOR ADDITIONAL
WATERPROOFING INFORMATION.
1. THIS SECTION IS INCLUDED FOR GENERAL REFERENCE OF WORK TO BE REMOVED BY THE GENERAL
CONTRACTOR.
FABRICATE AND ERECT TRUE, PLUMB AND SQUARE AS SPECIFIED AND AS DETAILED AND PER MANUFACTURER'S
RECOMMENDATIONS.
a. PRESERVATIVE TREATMENT FOR WOOD SPECIFIED ELSEWHERE.
7. AT LOCATIONS OF CONSTRUCTION JOINTS IN EXISTING SLAB, CONTINUE JOINTS THROUGH NEW FLOOR
IN LEVELING AREA. SAW CUT JOINT OR PLACE 1/16" WIDE METAL BAR IN THE JOINT LOCATION
COINCIDENT WITH EXISTING.
SELECTIVE DEMOLITION
C.
2. USE NON-COMBUSTIBLE FIRE RETARDANT TREATED (F.R.T.) WOOD ELSEWHERE AS REQUIRED BY STATE
AND LOCAL CODES, INCLUDING ANY WOOD STUDS, BLOCKING, FURRING, PLYWOOD, TRIM AND
GROUNDS. NEW LUMBER TO BEAR GRADE AND TREATMENT OF ASSOCIATION UNDER WHICH IT WAS
PRODUCED.
5. ROUGH IN CONCRETE IN AREAS WHERE PATCHING IS REQUIRED, SUCH AS CRACKED, SPALLED, OR HOLES
DUE TO REMOVAL OF EXISTING WORK.
PART 1 - GENERAL
PART 1 - GENERAL
BIDDING CONTRACTORS SHALL PREPARE A BID, WHICH SHALL BE SUBMITTED IN ACCORDANCE WITH
INSTRUCTIONS TO BIDDERS CONTAINED WITHIN BID DOCUMENT PACKAGE.
1. BLOCKING AND GROUNDS AT STOREFRONT GLAZING , LOCATIONS AT WEATHER AREAS,
CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.
4. REMOVE HIGH FLOOR LEVELS AND LOOSE CONCRETE.
DIVISION 02000 - SITE WORK
02060 BUILDING DEMOLITION
HARDWARE AND RELATED PARTS AND MATERIALS AS INDICATED ON DRAWINGS AND
08110 INSULATED STEEL DOORS
PROVIDE AND INSTALL WOOD FURRING, BLOCKING, GROUNDS AND IN-WALL BLOCKING FOR SUPPORT OF
GRAB BARS, FIXTURES, EQUIPMENT, CASEWORK, HARDWARE, TRIM AND SIMILAR WORK.
6. GRIND HIGH SPOTS.
01200 PRICE, PAYMENT, AND CONTRACT
A.
A.
1. DO NOT PROCEED WITH WORK UNTIL VISITING THE SITE AND DETERMINING CONDITIONS TO DECIDE
METHODS OF REPAIR. COORDINATE WITH TENANT'S CONSTRUCTION MANAGER.
END OF DIVISION
+1 (516) 393-2484
1. FOLLOW DOOR HARDWARE INSTITUTE (DHI) GUIDELINES.
COMPLY WITH MANUFACTURER'S REQUIREMENTS FOR INSTALLATION OF ITEMS AND FINISHES BY OTHER
TRADES, INCLUDING THOSE ITEMS AND FINISHES PROVIDED AND/OR INSTALLED BY TENANT.
PART 1 - GENERAL
PART 1 - GENERAL
MANUFACTURERS:
B.
WARRANTIES AND BONDS
LABELED DOORS: WHERE REQUIRED, PROVIDE U.L. LABEL DOORS AND FRAMES PER APPLICABLE STATE AND LOCAL BUILDING
CODES. SUCH TO RECEIVE LABELS ATTACHED STATING RATINGS.
A.
06100 WOOD BLOCKING AND CURBING
OPERATION AND MAINTENANCE DATA
B.
c. WELDING: COMPLY WITH AWS D1.1 "STRUCTURAL WELDING CODE".
PART 1 - GENERAL
A.
INSTALL ALL DOORS, FRAMES,
RESPONSIBILITY SCHEDULE.
PART 2 - PREPARATION /EXECUTION
1. MILCOR / DIVISION OF INRYCO, INC. BY BOSTWICK STEEL FRAMING, THE CECO ALLIED STRUCTURAL
INDUSTRIES; DIETRICH INDUSTRIES OR EQUAL.
PART 2 - PREPARATION / EXECUTION
ADJUSTING
A.
b. ANCHORAGE DEVICES: POWER ACTUATED FASTENERS, DRILLED EXPANSION BOLTS, OR SCREW WITH
SLEEVES.
THE EXTENT OF CONCRETE REPAIR WORK INCLUDES REMAINING FLOOR AREAS AFTERDEMOLITION PROVIDING
A LEVEL FLOOR THROUGHOUT TO RECEIVE FUTURE FINISHES.
1. EXECUTE AND ASSEMBLE TRANSFERABLE WARRANTY DOCUMENTS FROM SUBCONTRACTORS, SUPPLIERS,
AND MANUFACTURERS.
DELIVERIES
01041 PROJECT COORDINATION
D.
+1 (513) 765-6000
p
PART 1 - GENERAL
a. MANUFACTURER'S RECOMMENDED SELF-DRILLING, SELF-TAPPING SCREWS, BOLTS, NUTS AND
WASHERS. NON-CORROSIVE.
A.
2. PREPARE BINDER COVER WITH PRINTED TITLE "OPERATION AND MAINTENANCE INSTRUCTIONS", WITH
TITLE OF PROJECT, LOCATION AND DATE, AND SUBMIT TO TENANT'S CONSTRUCTION MANAGER.
3. ROOF REPAIRS OR PENETRATIONS REQUIRED BY REMOVAL OR RELOCATION OF EXISTING EQUIPMENT OR
INSTALLATION OF NEW EQUIPMENT (CUTTING OF ROOF AND DECK MATERIAL AND/OR REPAIR OF THE
SAME) SHALL BE COORDINATED WITH THE LANDLORD'S REPRESENTATIVE.
2. THE GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE ACCEPTABLE HOURS FOR DELIVERY AND
LOCATION OF DELIVERY OF BUILDING PRODUCTS AND TENANTS ITEMS WITH LANDLORD'S
REPRESENTATIVE.
EXPANSION JOINT MATERIAL: 1/2" PRE MOLDED ASPHALT IMPREGNATED FIBERBOARD, SAME DEPTH AS
CONCRETE.
p
6 Creamery Brook, East Granby, CT 06026
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
08100 HOLLOW METAL DOORS AND FRAMES
5. FASTENINGS:
PART 1 - GENERAL
1. SUBMIT DATA BOUND IN 8-1/2x11 INCH TEXT PAGES, THREE D SIDE RING BINDER WITH DURABLE PLASTIC
COVERS.
4. ALL SUB TRADES SHALL COORDINATE REMOVAL OF DEBRIS AND GARBAGE GENERATED BY THEIR TRADES
WITH THE G.C.
1. GENERAL CONTRACTOR IS RESPONSIBLE FOR UNLOADING ALL TENANT PROVIDED ITEMS AT THE JOB SITE
INCLUDING A HEAVY AMOUNT OF MILLWORK WHICH IS TENANT SUPPLIED. THESE TENANT SUPPLIED
ITEMS SHALL BE THE G.C.'S RESPONSIBILITY TO UNLOAD, STORE, AND DELIVER TO PROPER STORE AREAS
WHEN REQUIRED. SEE TITLE SHEET, "GENERAL NOTES", FOR ADDITIONAL NOTES, PROCEDURES, AND
RESPONSIBILITIES.
APPLY BONDING AGENT (AS SPECIFIED) TO ADJACENT CONCRETE SURFACES IMMEDIATELY PRIOR TO
PLACEMENT OF CONCRETE.
FINAL CLEANING
1. ADJUST OPERATING PRODUCTS AND EQUIPMENT TO ENSURE SMOOTH AND UNHINDERED OPERATION.
3. THERE WILL BE NO STORAGE OF MATERIAL OR RUBBISH IN CORRIDORS OR OTHER LANDLORDAREAS AT
ANY TIME. IF DEBRIS IS FOUND IN THIS AREA, IT WILL BE REMOVED AT THE EXPENSE OF THE CONTRACTOR
THAT IS RESPONSIBLE.
F.
PROVIDE SAW CUT CONTROL JOINTS 1/8" WIDTH x 1" DEEP AT MAXIMUM 400 SQUARE FOOT AREA.
DIVISION 08000 - DOORS AND WINDOWS
4. TRACK: ASTM A446/A446M GRADE A; MINIMUM YIELD STRESS OF 33 KSI (228 MPA); FORMED STEEL:
CHANNEL SHAPED; SAME WIDTH AND GAUGE AS ADJACENT STUDS. EXCEPTION: TOP AND BOTTOM
TRACK (RUNNERS) REQUIRING ATTACHMENT OF METAL PANELS SHALL BE MINIMUM 14 GAUGE
(0.08"/1.9MM).
FINISHES
J.
1. REMOVE WASTE AND SURPLUS MATERIALS, RUBBISH AND CONSTRUCTION DEBRIS FROM SITE.
GENERAL CONTRACTOR TO PROVIDE A PROFESSIONAL CLEANING SERVICE TO EXECUTE FINAL CLEANING
PRIOR TO TURN-OVER. SEE TITLE SHEET, "GENERAL NOTES", FOR ADDITIONAL INFORMATION.
2. MALL DOORS ARE NOT TO BE PROPPED OPEN BY CONSTRUCTION WORKERS AT ANY TIME.
2. THE LANDLORDS ROOFING CONTRACTOR WILL, AT SUBTRADES WRITTEN REQUEST AND COST, PROVIDE
THE OPENINGS, ANCHORING DEVISES, CURBS, FLASHINGS, PATCHING, ETC., AS REQUIRED FOR TENANTS
EQUIPMENT SO AS TO MAINTAIN THE INTEGRITY AND GUARANTEE OF THE ROOF. ALL SUBTRADES SHALL
INCLUDE THE COST OF SUCH OPENINGS, ETC. IN THEIR PROPOSALS TO TO THE GENERAL CONTRACTOR
DURING BIDDING. SUBTRADES SHALL COORDINATE WITH THE LANDLORD AND/OR ROOFING
CONTRACTOR AND ALSO REIMBURSE HIM FOR SAME.
GENERAL CONTRACTOR AND/OR SUB-CONTRACTOR ARE RESPONSIBLE AND SHALL INCLUDE IN THEIR BIDS ALL
NECESSARY EQUIPMENT INCLUDING CRANES, HOISTS, SCAFFOLDING, PLATFORMS, ETC., REQUIRED FOR
ERECTION OF BUILDING COMPONENTS, EQUIPMENT AND ALL TENANT SUPPLIED ITEMS AS LOCATED ON
PLANS. CONTRACTOR SHALL PAY ALL RELATED FEES, PERMITS, ETC. PROTECTION OF THE PUBLIC AND
EXISTING IN-PLACE WORK IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
PART 1 - GENERAL
2. DESIGN LOADS: LOADS AND CODE RESTRICTIONS FOR ALL DESIGN CONSIDERATIONS SHALL CONFORM
TO THE LOCAL AND STATE CODES AND ALL GOVERNING CODES.
1. CUTTING AND PATCHING FOR ALL ROOF OPENINGS SHALL BE PERFORMED BY LANDLORDS ROOFING
CONTRACTOR, IF SO REQUIRED BY THE LANDLORD, ENGAGED BY TENANTS GENERAL CONTRACTOR.
b. 12-16 GAUGE (0.11"/2.7MM - 0.06"/1.5MM): ASTM A446/A446M GRADE A; MINIMUM YIELD STRESS OF
40 KSI (276 MPA).
COMPACT SUB GRADE FOR SLABS ON GRADE TO 95 CRUSHED GRAVEL SUB-BASE AT ALL AREAS TO RECEIVE
NEW CONCRETE.
I.
MATERIALS:
1. 18 GAUGE AND LIGHTER COMPONENTS: FABRICATE COMPONENTS OF COMMERCIAL QUALITY STEEL
SHEET, ASTM A446 FOR GALVANIZED FINISH WITH A MINIMUM YIELD POINT OF 33,000 PSI.
1. GIVE TYPICAL INTERIOR FLOOR SLABS A STEEL TROWEL FINISH WITH CLASS A TOLERANCE (TRUE PLANES
WITHIN 1/8 IN 10 FT. AS DETERMINED BY A 10 FOOT STRAIGHTEDGE PLACED ANYWHERE ON SLAB IN ANY
DIRECTION).
K.
01700 CLEANING / ADJUSTING / MAINTENANCE / WARRANTIES
CODES AND STANDARDS
ROOF CUTTING AND PATCHING
GENERAL CONTRACTOR TO VERIFY PROVISIONS FOR TEMPORARY UTILITIES INCLUDING ELECTRICITY, LIGHTING,
HEAT, VENTILATION, TELEPHONE SERVICE, WATER AND SANITARY FACILITIES. G.C. TO INCLUDE A FULL TIME
PHONE AND FAX ON SITE CAPABLE OF INCOMING CALLS DURING ENTIRE CONSTRUCTION PERIOD.
C.
PART 1 - GENERAL
1. ALL WORK, MATERIALS, AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH ALL ORDINANCES,
STATE AND LOCAL BUILDING CODES, LATEST EDITION. SEE TITLE SHEET FOR SPECIFIC EDITIONS.
E.
H.
01542 CRANES AND HOISTS
4. SHOULD A CONTRACTOR FIND DISCREPANCIES IN, OR OMISSIONS FROM THE DRAWINGS OR
SPECIFICATIONS, OR SHOULD HE BE IN DOUBT AS TO THEIR MEANING, HE SHALL AT ONCE NOTIFY THE
ARCHITECT AND TENANT.
5. THE G.C. SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL DEBRIS INCLUDING PACKAGING MATERIAL OF
MILLWORK.
G.
PART 1 - GENERAL
3. GENERAL CONTRACTOR IS TO LAYOUT WORK AND BE RESPONSIBLE FOR ALL LINES, MEASUREMENTS OF
THE BUILDING, UTILITIES, AND OTHER WORK EXECUTED UNDER THE CONTRACT.
1. ALL TRADES SHALL CONFINE CONSTRUCTION WORK TO WITHIN LEASED PREMISES AS MUCH AS POSSIBLE
AND SHALL WORK IN AN ORDERLY MANNER REMOVING TRASH AND DEBRIS FROM PROJECT ON A DAILY
BASIS INCLUDING TRASH AND DEBRIS GENERATED BY TENANT SUPPLIED AND/OR INSTALLED ITEMS. AT
NO TIME WILL PIPES, WIRES, BOARD, OR OTHER CONSTRUCTION MATERIALS CROSS PUBLIC AREAS WHERE
HARM COULD BE CAUSED TO THE PUBLIC.
ALL ITEMS SHALL BE INSTALLED USING STANDARD PROFESSIONAL PRACTICES USING FASTENERS, ADHESIVES
AND METHODS REQUIRED BY MANUFACTURER AND INDUSTRY MANUALS.
01510 TEMPORARY UTILITIES
LAYOUT OF WORK
TRASH REMOVAL
F.
01426 PROCEDURES
2. EXERCISE PROPER PRECAUTION TO VERIFY ALL EXISTING CONDITIONS AND LAYOUT OF CONTRACTOR TO
NOTIFY TENANT OF ANY DISCREPANCIES IMMEDIATELY. CONTRACTOR IS RESPONSIBLE FOR ANY ERROR
RESULTING FROM FAILURE TO EXERCISE SUCH PRECAUTION. SUCH ERROR WILL NOT BE CONSIDERED
SUBSEQUENTLY AS A BASIS FOR EXTRA COMPENSATION.
D.
GENERAL CONTRACTOR AND/OR SUB CONTRACTOR SHALL GUARANTEE HIS WORKMANSHIP AND MATERIALS
FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY THE OWNER.
PART 1 - GENERAL
1. IMMEDIATELY AFTER DEMOLITION, GENERAL CONTRACTOR TO ADVISE TENANT OF ANY DISCREPANCIES
IN OVERALL WIDTH, LENGTH, AVAILABLE CEILING HEIGHTS, COLUMN LOCATIONS, STOREFRONT, UTILITY
LOCATIONS, ETC.
C.
ALL WORK SHALL BE EXECUTED BY TRADESMEN AND MECHANICS QUALIFIED, THROUGH EXPERIENCE, IN THEIR
RESPECTIVE TRADES. SAID CONTRACTORS SHALL REMOVE AND REPLACE WITHOUT DELAY AND WORK
CONTRARY TO THE CONTRACT DOCUMENTS WHEN SPECIFICALLY DIRECTED.
VERIFY THAT COMPACTED GRANULAR BASE IS IN PLACE AND READY TO SUPPORT PAVINGAND IMPOSED
LOADS.
4000 Luxottica Place, Mason, OH 45040
a
FR I A R
DIVISION 01000 - GENERAL REQUIREMENTS
01000 GENERAL NOTES
a
B.
INSTALLATION
QUALITY ASSURANCE - DESIGN AND ANALYSIS OF STRUCTURAL PROPERTIES SHALL COMPLY WITH AISI
"SPECIFICATION FOR THE DESIGN OF COLD-FORMED STRUCTURAL STEEL MEMBERS".
END OF DIVISION
Title
SPECIFICATIONS
1 of 2
Date
07-01-16
Drawn By
LLB
Checked By
ANP
Sheet
G003
A.
COORDINATE THE WORK WITH OTHER DIRECTLY AFFECTED SECTIONS INVOLVING MANUFACTURE OR
FABRICATION OF INTERNAL REINFORCEMENT FOR DOOR HARDWARE AND RECESSED ITEMS.
B.
VERIFY THAT DOORS AND FRAMES ARE READY TO RECEIVE WORK AND DIMENSIONS ARE AS INDICATED.
C.
INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
D.
USE TEMPLATES PROVIDED BY HARDWARE ITEM MANUFACTURER.
E.
ADJUST HARDWARE FOR SMOOTH OPERATION.
08800 GLAZING
PART 1 - GENERAL
A. FURNISH AND INSTALL A COMPLETE SYSTEM OF GLASS, GLAZING CHANNELS, SEALANT, SETTING BLOCKS
AND ACCESSORIES AS SHOWN AND DETAILED ON THE DRAWINGS AND RESPONSIBILITY SCHEDULE.
B.
SEE PLANS AND ELEVATIONS FOR SIZE AND NUMBER OF PANES.
C.
FOLLOW RECOMMENDATIONS FOR INSTALLATION CONTAINED IN THE FGMA (FLOAT GLASS
MANUFACTURERS ASSOCIATION) GLAZING AND SEALANT MANUALS AS WELL AS SIGMA (SEALED
INSULATED GLASS MANUFACTURE. ASSOCIATION) FOR INSULATED GLASS.
D.
E.
F.
5. COVER TAPED AND FILLED JOINTS AND FILLED SCREW HEAD DEPRESSIONS WITH TOPPING
COMPOUND APPLIED IN THREE COATS. PERMITTING THE PREVIOUS COAT TO DRY PRIOR TO
INSTALLING THE SUBSEQUENT COAT.
6. SAND JOINT AND SCREW HEAD AREAS LIGHTLY BETWEEN COATS AND AFTER THE FINAL COAT SO
THAT A SMOOTH LEVEL SURFACE IS PRODUCED WITH THE PAPER SURFACE OF THE WALLBOARD FREE
OF SCUFFING.
F.
PATCH AND/OR REPAIR EXISTING DRYWALL TO REMAIN TO LIKE NEW CONDITION. LEVEL ANY UNEVEN OR
ROUGH SPOTS AND FINISH SMOOTH. BULGES AND VISUAL DEPRESSIONS ARE NOT ACCEPTABLE.
G.
INSTALL CEMENTITIOUS BACKER BOARD AT ALL AREAS TO RECEIVE TILE OR MARBLE, OR AS SHOWN ON
=DRAWINGS.
H.
ACCESS PANELS:
1. G.C. SHALL PROVIDE AND INSTALL ACCESS PANELS AS REQUIRED BY LANDLORD AND SITE
CONDITIONS (COORDINATE SIZE REQUIREMENTS, NUMBER OF PANELS REQUIRED AND LOCATIONS
WITH LANDLORD AND ALL MECHANICAL TRADES).
IT IS THE GLAZING CONTRACTORS SOLE RESPONSIBILITY TO VERIFY THAT THE GLASS IS SIZED TO
WITHSTAND DEAD LOADS, POSITIVE AND NEGATIVE LIVE LOADS, ACTING NORMAL TO PLANE OF GLASS AS
CALCULATED IN ACCORDANCE WITH LOCAL AND STATE CODES.
2. ACCESS PANELS SHALL BE FLUSH TYPE (NO EXPOSED FLANGES) STYLE AS MANUFACTURED BY:
INTEX FORMS INC. - GLASS FIBER (GFRG) FLUSH ACCESS PANEL
1.
CLEAR GLASS - ASTM C1048, FT-FULLY TEMP., QUALITY-q3 GLAZING SELECT.
2.
THICKNESS AS SHOWN ON PLAN.
3.
EACH INDIVIDUAL PANE TO RECEIVE TEMPERED STAMP INDICATING SUCH.
MATERIAL FOR EXTERIOR STOREFRONT IN METAL GLAZING SYSTEM.
INSULATED GLASS UNITS - LOW E - TYPE SG-B - ASTM E774 AND E773 DOUBLE PANE WITH GLASS
ELASTOMER EDGE SEAL; OUTER PANE OF CLEAR GLASS, INNER PANE OF LOW E CLEAR GLASS ON
CLEAR COLOR GLASS.
a.
PROVIDE TEMPERED GLASS UNITS WHERE INDICATED ON PLAN OR AS REQUIRED BY
JURISDICTIONAL CODES.
PART 2 - PREPARATION / EXECUTION
A.
VERIFY THAT OPENINGS FOR GLAZING ARE CORRECTLY SIZED AND WITHIN TOLERANCE.
VERIFY THAT SURFACES OF GLAZING CHANNELS OR RECESSES ARE CLEAN, FREE OF OBSTRUCTIONS THAT
MAY IMPEDE MOISTURE MOVEMENT, WEEPS ARE CLEAR, AND READY TO RECEIVE GLAZING.
(SIZE AS REQUIRED)
3. PANELS TO BE FACTORY PRIMED (WHITE) READY TO RECEIVE FINAL FINISH PAINT BY G.C.
09300 TILE AND MARBLE
PART 1 - GENERAL
A. MARBLE/CERAMIC/QUARRY TILE: REFER TO FINISH AND RESPONSIBILITY SCHEDULE FOR SIZES, COLORS,
AND MANUFACTURERS.
B.
INSTALL GROUT AS RECOMMENDED BY THE TILE MANUFACTURER. COLOR OF WALL GROUT TO BE
INDICATED ON THE FINISH SCHEDULE. IF NO COLOR IS INDICATED, A GROUT TO MATCH TILE IS TO BE
USED.
C.
ALL CERAMIC TILE BASES INSTALLED SHALL BE SANITARY COVE TYPE. REFER TO FINISH SCHEDULE FOR
SPECIFICATIONS.
C.
CUT GLASS PANES TO ACCURATE SIZES ALLOWING FOR EDGE CLEARANCES AND TOLERANCES.
PART 2 - PREPARATION / EXECUTION
REFER TO SECTION 03732 "CONCRETE REPAIR / PREPARATION". AND TO SECTION 07200 "INSULATION AND
WATERPROOFING"
D.
INSTALL SEALANTS RECOMMENDED BY MANUFACTURER WHICH ARE COMPATIBLE WITH MATERIALS THEY
WILL BE IN CONTACT WITH.
A.
E.
REMOVE GLAZING MATERIALS FROM FINISH SURFACES.
F.
REMOVE LABELS AFTER WORK IS COMPLETE.
G.
CLEAN GLASS AND ADJACENT SURFACES.
08835 MIRROR
B.
BEFORE SETTING ANY TILE, THE CONTRACTOR SHALL ASSURE HIMSELF THAT NO TILES WILL HAVE TO BE
REMOVED AFTER INSTALLATION TO ACCOMMODATE THE WORK OF OTHER TRADES. ALL CUTTING,
FITTING, DRILLING AND GRINDING OF THE WORK, WHERE NECESSARY IN RELATION TO THE WORK OF
OTHER TRADES, SHALL BE PERFORMED SO THAT THE WORK WILL BE NEATLY AND ACCURATELY DONE AND
CUT EDGES SHALL BE UNIFORM.
CONFORM TO REQUIREMENTS UNDER AMERICAN NATIONAL STANDARDS INSTITUTE ANSI A-137.1 FOR
CERAMIC TILE MATERIAL AND ANSI A-108 FOR INSTALLATION.
C.
INSTALL PER LANDLORD'S SPECIFICATIONS, WHERE APPLICABLE.
PART 1 - GENERAL
A. FURNISH AND INSTALL CUSTOM FITTED MIRRORS INCLUDING MASTIC AND ATTACHMENT CLIPS AS SIZED
AND DETAILED IN DRAWINGS AND RESPONSIBILITY SCHEDULE. REFER TO TOILET ROOM ACCESSORIES FOR
TENANT-PROVIDED MIRRORS IN LAVATORY. VERIFY WITH TENANT'S PROJECT MANAGER.
D.
LAY OUT TILE PATTERN SYMMETRICALLY WITH EVEN JOINT ON ALL FLOOR AND WALL SURFACES. ALIGN
JOINTS WITH MALL PATTERN, WHERE APPLICABLE.
E.
CUT AND DRILL TILE AS REQUIRED WITHOUT MARRING TILE, GRIND AND FIT AROUND FIXTURES, ETC.. LEAVE
COMPLETED WORK FREE FROM CRACKED, BROKEN, OR DAMAGED TILE.
B.
CONSULT NAMM (NATIONAL ASSOCIATION OF MIRROR MANUFACTURING) FOR TIPS FOR CARE AND
HANDLING OF MIRRORS.
F.
ALL TRANSITIONS BETWEEN NEW AND EXISTING OR UNLIKE FINISHES SHALL BE FLUSH AND SMOOTH. NO
REDUCER STRIPS PERMITTED IN STOREFRONT AREA.
C.
PRODUCT:
H.
PROTECT HEAVILY TRAVELED, NEWLY TILED AREAS AS REQUIRED.
I.
INSTALL TILES USING THINSET METHOD WITH 1/16" JOINTS AT WALLS AND FLOORS.
J.
SEAL/WAX ALL TILE PER MANUFACTURER'S SPECIFICATIONS.
1. CLEAR FLOAT TYPE WITH COPPER/SILVER COATING. UNLESS NOTED OTHERWISE, ALL EDGES SHALL BE
POLISHED.
D.
MIRROR ADHESIVE: CHEMICALLY COMPATIBLE WITH MIRROR COATING AND WALL SUBSTRATE.
PART 2 - PREPARATION / EXECUTION
A.
VERIFY AREAS RECEIVING MIRRORS ARE WITHIN TOLERANCES AND ARE READY TO RECEIVE MATERIAL.
B.
PLACE PLUMB AND LEVEL WITHOUT VISIBLE DISTORTION.
C.
STORE, PROTECT, AND INSTALL MIRRORS IN ACCORDANCE WITH NAMM.
D.
SET MIRRORS WITH EDGE CLEARANCE FREE OF SURROUNDING CONSTRUCTION INCLUDING COUNTERTOPS
OR BACKSPLASHES.
E.
REMOVE LABELS AFTER WORK IS COMPLETE.
F.
CLEAN MIRRORS AND ADJACENT SURFACES.
END OF DIVISION
09120 CEILING SUSPENSION SYSTEMS
09650 VINYL RESILIENT TILE FLOORING
PART 1 - GENERAL
A.
G.C. TO SUPPLY AND INSTALL 1/8" X 12" X 12" VINYL RESILIENT TILES, AS SHOWN AND SPECIFIED ON THE
DRAWINGS.
B.
INSTALL 4" HIGH X 1/8" THICK, TOP SET, COVED VINYL BASE, AT ALL WALLS IN AREAS TO RECEIVE VINYL
TILE FLOORING, AS SPECIFIED ON DRAWINGS.
C.
SEE FINISH SCHEDULE FOR SPECIFIC COLORS AND MANUFACTURER.
C.
REFER TO DRAWINGS FOR LOCATION OF SPECIFIED MATERIALS AND FINISHES. WHERE REQUIRED BY CODES,
CEILING ASSEMBLIES ARE TO CONFORM WITH UNDERWRITERS LABORATORIES DESIGN FOR ONE HOUR FIRE
RATED ASSEMBLIES.
09652 WOOD FLOORING
E.
INSTALL EDGE MOLDINGS AT PERIMETER OF ACOUSTICAL CEILING AREA AND AT LOCATIONS WHERE
NECESSARY TO CONCEAL EDGES OF ACOUSTICAL UNITS.
F.
INSTALL ACOUSTICAL PANELS IN COORDINATION WITH SUSPENSION SYSTEM, WITH EDGES CONCEALED BY
SUPPORT OF SUSPENSION ,MEMBERS, SCRIBE AND CUT PANELS TO FIT ACCURATELY AT BORDERS AND
PENETRATIONS.
G.
INSTALL HOLD-DOWN CLIPS IF REQUIRED BY CODE.
H.
GWB CEILINGS AND SOFFITS TO BE GIVEN A FLAT AND SMOOTH FINISH TO ACCEPT PAINT FINISH. REFER TO
SECTION 09250 "GYPSUM BOARD SYSTEMS".
09250 GYPSUM BOARD SYSTEMS
LEVEL 5 GYPSUM BOARD FINISH SPECIFICATION:
A.
ALL JOINTS AND INTERIOR ANGLES SHALL HAVE TAPE EMBEDDED IN JOINT COMPOUND AND TWO
SEPARATE COATS OF JOINT COMPOUND APPLIED OVER ALL FLAT JOINTS AND ONE SEPARATE COAT OF
JOINT COMPOUND APPLIED OVER INTERIOR ANGLES. FASTENER HEADS AND ACCESSORIES SHALL BE
COVERED WITH THREE SEPARATE COATS OF JOINT COMPOUND. A THIN SKIM COAT OF JOINT COMPOUND
OR A MATERIAL MANUFACTURED ESPECIALLY FOR THIS PURPOSE, SHALL BE APPLIED TO THE ENTIRE
SURFACE. THE SURFACE SHALL BE SMOOTH AND FREE OF TOOL MARKS AND RIDGES. NOTE: IT IS
RECOMMENDED THAT THE PREPARED SURFACE BE COATED WITH A DRYWALL PRIMER PRIOR TO THE
APPLICATION OF FINISH PAINT.
PART 1 - GENERAL
A. FINISHED WOOD FLOOR AS SPECIFIED IN FINISH AND RESPONSIBILITY SCHEDULES. INSTALLED PER
MANUFACTURER'S PRINTED INSTRUCTIONS AND RECOMMENDATIONS.
B.
MATERIALS SHALL BE LISTED WITH UNDERWRITERS LABORATORIES AS TO FIRE AND SLIP RESISTANCE.
C.
ARCHITECTURAL TRIM, i.e. REDUCER STRIPS, BANDS, PICKETS, ETC., SHALL BE OF SAME MANUFACTURER
AND FINISH AS WOOD FLOOR.
PART 2 - PREPARATION / EXECUTION
REFER TO SECTION 03732 "CONCRETE REPAIR / PREPARATION". AND TO SECTION 07200
"INSULATION AND WATERPROOFING"
A.
GENERAL CONTRACTOR TO BROOM CLEAN FLOORING AS IT IS INSTALLED. PROTECT FLOORING
IMMEDIATELY WITH BROWN KRAFT PAPER AND INSTALL MASONITE, ORIENTED STRAND BOARD OR OTHER
PROTECTIVE FLOOR PANELS OVER ENTIRE WOOD FLOOR.
B.
NO FLOORING TO BE EXPOSED UNTIL LAST DAY OF FIXTURING AND PROP INSTALLATION.
C.
FLOOR CLEAN-UP: FOLLOWING COMPLETION OF WORK BY OTHER TRADES, THE PROTECTIVE COVERING
PLACED AFTER INSTALLATION SHOULD BE REMOVED; FOLLOWED BY SWEEPING, VACUUMING AND/OR DRY
MOPPING TO REMOVE ALL LOOSE DEBRIS.
09680 CARPET
PART 1 - GENERAL
A.
CONDITION CARPET AND ADHESIVES FOR AT LEAST 48 HOURS AT A MINIMUM TEMPERATURE OF 65
DEGREES FAHRENHEIT. THE FLOOR SHOULD ALSO BE CONDITIONED AT A TEMPERATURE ABOVE 65
DEGREES F FOR AT LEAST 24 HOURS PRIOR TO INSTALLATION. THE FLOOR MUST BE SWEPT FREE OF DUST
AND DEBRIS.
B.
NEW CONCRETE MUST BE CURED PREFERABLY FOR 90 DAYS BEFORE INSTALLING CARPET. CHECK THE SLAB
FOR ALKALINITY, WHICH SHOULD BE LESS THAN 9.0 pH IF NECESSARY, NEUTRALIZE THE FLOOR WITH AN
ACID WASH OF 10 PARTS WATER TO ONE PART MURIATIC ACID AND RINSE THOROUGHLY. A SEALER
SHOULD BE USED TO INSURE A GOOD BONDING SURFACE. EXISTING CONCRETE MAY REQUIRE RESEALING
TO ASSURE A PROPER SURFACE.
C.
REMOVE, REPLACE OR PATCH OLD VINYL TILE OR LINOLEUM, STRIP OLD WAX BY MOPPING WITH
AMMONIA AND WATER, AND FILL IN GROUT LINES ON CERAMIC FLOORS WITH A LATEX FLASHING
COMPOUND, AS APPLICABLE.
D.
REMOVE ANY FINISHES, WAXES, PAINT, ETC. FROM WOOD FLOORS. THE SURFACE MUST BE LEVEL AND
CRACKS MAY REQUIRE A FLASHING COMPOUND. PLYWOOD OR PARTICLE BOARD MAY BE NECESSARY TO
OFFSET UNEVEN FLOORS, BUT MUST BE PRIMED PRIOR TO INSTALLATION.
PART 1 - GENERAL
A. FURNISH AND INSTALL ALL GYPSUM DRYWALL AND SYSTEMS COMPLETE WITH PARTITION FRAMING,
CEILING SUSPENSION SYSTEMS AND RELATED ACCESSORIES, PARTS, MATERIALS, ETC. AS SHOWN ON
DRAWINGS AND AS SPECIFIED. INSTALL ALL MATERIALS PER MANUFACTURERS SPECIFICATIONS AND
RECOMMENDATIONS.
E.
CUT-BACK ADHESIVE MUST BE FLASHED OVER. USING A NOTCHED TROWEL, PATCH AND LET CURE.
SMOOTH OVER WITH A SECOND COAT OF PATCH, USING THE FLAT SIDE OF THE TROWEL TO FILL IN THE
RIDGES. ALLOW THE NEWLY FLASHED FLOOR TO CURE.
B.
GYPSUM DRYWALL: ALL GYPSUM BOARD TO BE 5/8" TYPE "X" AS NOTED ON NEW CONSTRUCTION PLAN.
REST ROOMS TO RECEIVE MOISTURE RESISTANT GYPSUM BOARD.
F.
C.
FASTENERS: DRYWALL SCREWS OF PROPER SIZE AND TYPE PER MANUFACTURERS RECOMMENDATIONS.
CARPET CONTRACTOR TO ESTABLISH HIS OWN TAKEOFFS AND COORDINATE HIS TAKEOFFS WITH THE
AMOUNT SHIPPED BY TENANT AND CONTACT THE CONSTRUCTION COORDINATOR OF ANY
DISCREPANCIES.
D.
PROVIDE MATERIALS, JOINT COMPOUNDS, TRIM, EDGES, BEADS, ETC. FROM A SINGLE SOURCE SUPPLIER.
ALL TRIM SHALL CONSIST OF A TAPERED, GROOVED, AND PREPUNCHED FIN FOR SCREW ATTACHMENT
AND TO ACCEPT BONDING AGENT. ALL BUTT JOINTS ARE TO BE NEAT WITH TIGHT JOINTS, AND ALL
CORNERS ARE TO BE MITERED. ALL EDGES, BEADS AND TRIM TO BE PRE-FINISH ALUMINUM.
G.
INSTALL PER FLOOR AND WALL FINISH PLAN AND PROVIDE TENANT WITH SEAM LAYOUT PRIOR TO
CUTTING / INSTALLATION. H. FILL ALL CRACKS, JOINTS, ETC. IN SUB-FLOOR WITH CRACK FILLER APPROVED
BY CARPET MANUFACTURER.
E.
H.
JOINT TREATMENT: U.S. GYPSUM OR GOLD BOND SYSTEM OF COMPOUNDS AND PERFORATED TAPE.
1.
ERECT GWB IN A SINGLE LAYER IN THE MOST ECONOMICAL DIRECTION WITH
ENDS AND EDGES OCCURRING OVER FIRM BEARING.
2.
WALLS, CEILINGS AND SOFFITS, AND ALL TRANSITIONS IN SAME, SHALL BE
GIVEN A SMOOTH FINISH.
3. CORNER BEADS SHALL BE APPLIED TO ALL EXTERNAL ANGLES IN STRICT ACCORDANCE WITH THE
MANUFACTURERS DIRECTIONS. INSTALL CASING BEADS AT ALL EDGES OF DRYWALL WORK EXCEPT
WHERE TERMINATION IS COVERED BY OTHER FINISH. CASING BEADS SHALL BE MITERED AT CORNERS
AND INSTALLED NEATLY, FINISHED WITH COMPOUND.
INSTALL "WHISPERWALK".
E.
INSTALL LAMINATE FLOORING AS A "FLOATING" FLOOR. BEGIN INSTALLATION ALONG WALL WITH
TONGUE FACING WALL ACCORDING TO MANUFACTURER'S PROCEDURES. APPLY GLUE TO GROOVES WITH
PLANKS IN PLACE ON FLOOR. ENSURE JOINTS ARE COMPLETELY SEALED WITH GLUE. DO NOT NAIL, SCREW
OR FASTEN FLOORING TO SUBFLOOR.
F.
PROVIDE ADEQUATE EXPANSION SPACE AT PERIMETER, COLUMNS, AND AT ALL ALL OTHER
OBSTRUCTIONS.
G.
INSTALL SPECIFIED BASE OR TRIM AT PERIMETER, COLUMNS, AND AT ALL OTHER OBSTRUCTIONS.
H.
NO FLOORING TO BE EXPOSED UNTIL LAST DAY OF FIXTURING AND MERCHANDISE INSTALLATION.
I.
FLOOR CLEANUP: FOLLOWING COMPLETION OF WORK BY OTHER TRADES, THE PROTECTIVE COVERING
PLACED AFTER INSTALLATION SHOULD BE REMOVED; FOLLOWED BY SWEEPING, VACUUMING AND/OR DRY
MOPPING TO REMOVE ALL LOOSE DEBRIS.
PROVIDE DIRECT GLUEDOWN INSTALLATION USING MATERIAL AND METHODS RECOMMENDED BY CARPET
MANUFACTURER. SEAL ALL SEAMS WITH SEAM ADHESIVE.
09700 LAMINATED WOOD FLOORING
p
+1 (513) 765-6000
6 Creamery Brook, East Granby, CT 06026
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Macy's Store Number: (687)
Revisions:
Mark
B.
1
PREP FLOOR AS RECOMMENDED BY THE MANUFACTURER.
C.
INSTALL COMPLETE PER MANUFACTURER'S SPECIFICATIONS, INCLUDING ALL TRANSITION STRIPS AND
EXPANSION JOINTS AS REQUIRED FOR PROPER INSTALLATION.
By
07/07/16
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
USE ONLY THE PAINT AND RELATED MATERIALS SPECIFIED BY THE MANUFACTURER. SEE FINISH SCHEDULE
FOR SPECIFIC COLORS. ALTERNATES ARE NOT PERMITTED.
PART 2 - PREPARATION / EXECUTION
A.
CLEAN ALL SURFACES TO BE PAINTED FREE OF LOOSE DIRT AND DUST BEFORE WORK IS STARTED. WASH
ALL METAL SURFACES WITH MINERAL SPIRITS BEFORE APPLYING FINISHES. WHERE RUST OR SCALE IS
PRESENT, WIRE BRUSH OR SAND CLEAN BEFORE APPLYING FINISH.
B.
PAINTED DRYWALL TO RECEIVE ONE COAT LATEX PRIMER AND TWO COATS OF SPECIFIED
PAINT. TINT PRIMER TO APPROXIMATE SHADE OF THE FINAL COAT. TOUCHUP ALL SUCTION SPOTS OR HOT
SPOTS AFTER APPLICATION OF FIRST COAT AND BEFORE APPLYING SECOND COAT, TO PRODUCE AND
EVEN RESULT IN THE FINISH COAT. DRY ALL COATS THOROUGHLY BEFORE APPLYING SUCCEEDING COATS.
FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR RECOAT TIME. SEAL ALL DRYWALL SURFACES
BEHIND MIRRORS.
C.
PUTTY ALL NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE APPLYING FINISH.
D.
SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH.
E.
BEFORE STARTING FINISH WORK, REMOVE HARDWARE, ACCESSORIES, PLATES, LIGHTING FIXTURES AND
SIMILAR ITEMS, OR PROVIDE AMPLE PROTECTION FOR SUCH ITEMS.
F.
PAINT ALL EXPOSED PIPING, ACCESS DOORS, VENTS, FIRE EXTINGUISHER CABINETS, EQUIPMENT
MOUNTING BOARDS, ETC. TO MATCH ADJACENT WORK UNLESS OTHERWISE NOTED OR DIRECTED.
G.
SAND ENAMELED FINISHES APPLIED TO WOOD OR METAL BETWEEN COATS WITH FINE SANDPAPER TO
PRODUCE EVEN SMOOTH FINISH.
H.
MAKE FINISH WORK UNIFORM, SMOOTH, FREE OF RUNS, SAGS AND DEFECTIVE BRUSHING OR SPRAYING.
MAKE EDGES ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING.
I.
SEAL TOPS, BOTTOMS AND EDGES OF ALL DOORS.
J.
K.
Architect of Record
CONTRACTOR TO LEAVE ONE QUART EACH COLOR OF PAINT FOR FUTURE TOUCH-UP.
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
2016-026A
Seal
PRIOR TO CONTRACTOR LEAVING SITE AND AFTER ALL FIXTURES ARE INSTALLED AND STORE IS CLEANED,
CONTRACTOR TO WALK SITE AND TOUCH-UP PAINT DAMAGED DURING FINAL DAYS OF PROJECT.
END OF DIVISION
DIVISION 10000 - SPECIALTIES
10520 FIRE PROTECTION
PART 1 - GENERAL
A. PROVIDE MULTI-PURPOSE CHEMICAL FIRE EXTINGUISHERS CAPABLE OF EXTINGUISHING CLASS A, B, AND C
FIRES, IN QUANTITIES AND LOCATIONS REQUIRED BY LOCAL FIRE MARSHALL. (COORDINATE IN FIELD.)
MANUFACTURER: J.L. INDUSTRIES; COSMIC SERIES OR EQUAL.
10800 TOILET ROOM ACCESSORIES
NAME:
GLENN S. YEAKEL
DATE:
07-01-16
REG NO:
20474
Engineer
PART 1 - GENERAL
A.
TENANT TO SUPPLY A.D.A. APPROVED TOILET ACCESSORIES AND GRAB BARS INCLUDING ALL SET SCREWS
AND ANCHORS REQUIRED FOR COMPLETE INSTALLATION.
PART 2 - PREPARATION / EXECUTION
A.
G.C. SHALL INSTALL TOILET ACCESSORY UNITS ACCORDING TO MANUFACTURER'S INSTRUCTIONS, USING
FASTENERS AND IN WALL BLOCKING AS RECOMMENDED BY UNIT MANUFACTURER. INSTALL UNITS PLUMB
AND LEVEL, FIRMLY ANCHORED IN LOCATIONS AND AT HEIGHTS INDICATED, IN A TAMPERPROOF MANNER
WITH SPECIAL HANGERS, TOGGLE BOLTS, OR SCREWS.
END OF DIVISION
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
DIVISION 11000 - EQUIPMENT
11001 EQUIPMENT
PART 1 - GENERAL
A.
CONTRACTOR SHALL COORDINATE ALL EQUIPMENT WORK AND PLACEMENT WITH THE WORK OF ALL
OTHER TRADES AND MAKE ADJUSTMENTS AS REQUIRED TO ACCOMMODATE LOCATIONS OF EQUIPMENT.
B.
ALL EQUIPMENT WORK SHALL COMPLY WITH ALL GOVERNING BUILDING CODES AND LOCAL
C.
EQUIPMENT SHALL BE FURNISHED, UNLOADED, UNPACKED OR UNCRATED AND PLACED ACCORDING TO
THE CONSTRUCTION DOCUMENTS.
Seal
PART 2 - PREPARATION / EXECUTION
A.
GENERAL CONTRACTOR'S INSTALLATION OF TENANT SUPPLIED EQUIPMENT IS TO BE INCLUDED IN
GENERAL BID.
B.
GENERAL CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER IMMEDIATELY OF ANYDAMAGE TO
THE EQUIPMENT PRIOR TO INSTALLATION.
C.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL HOOKUP OF ALL EQUIPMENT, INCLUDING ALL
MECHANICAL, PLUMBING AND ELECTRICAL WORK.
D.
ALL EQUIPMENT MANUALS, INSTRUCTION BOOKLETS AND WARRANTY INFORMATION SHALL BE NEATLY
BOUND AND TURNED OVER TO THE CONSTRUCTION MANAGER PRIOR TO THE TURNOVER.
E.
STEAM PRESS SUPPLIED BY TENANT SHALL BE INSTALLED BY G.C.'S CERTIFIED STEAM FITTER/PLUMBER FOR
FINAL CONNECTIONS.
11110 MISCELLANEOUS
PART 1 - GENERAL
A.
GENERAL CONTRACTOR TO INSTALL TRAFFIC COUNTING SYSTEM PER MANUFACTURER'S SPECIFICATIONS.
1. THE SYSTEM'S TRANSMITTER AND REFLECTOR ARE TO BE INSTALLED AT EACH PUBLIC ENTRANCE, 52"
A.F.F., AS INDICATED IN DRAWINGS. DOOR SWING NOR ANY OTHER OBSTRUCTION SHOULD BLOCK
THE "BEAM" PATH.
2. THE SYSTEM'S RECEIVER IS TO BE INSTALLED IN CASH-DESK CABINETRY.
B.
GENERAL CONTRACTOR TO INSTALL FULL HEIGHT, WHITE CORNER GUARDS WITH WHITE ADHESIVE WHERE
INDICATED ON DRAWINGS.
END OF DIVISION
NAME:
DATE:
REG NO:
Nextore project
Number
73052
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
PART 1 - GENERAL
A.
WOOD LAMINATE FLOORING: REFER TO FINISH AND RESPONSIBILITY SCHEDULE FOR SIZES, COLORS, AND
MANUFACTURERS.
B.
Date
09910 PAINTING AND FINISHING
PART 1 - GENERAL
A.
THE INTENT IS TO PROVIDE A SATISFACTORY FINISH TO ALL PARTS OF THIS PROJECT. FINISH APPEARANCE
MUST BE UNIFORM, SMOOTH, AND FREE OF ANY RUNS, SAGS, AND DEFECTIVE BRUSHING OR SPRAYING.
COVER ALL SURFACES THOROUGHLY IF THE NUMBER OF COATS RECOMMENDED BY MANUFACTURER DOES
NOT ACCOMPLISH THE INTENT, THEN APPLY ADDITIONAL COATS UNTIL COVERAGE IS SATISFACTORY. SEE
FINISH SCHEDULE FOR PAINT COLORS, MANUFACTURER, ETC.
ALL SALES AREAS AND PUBLIC AREAS TO HAVE RECESSED BRASS CABINETS PROVIDED AND INSTALLED BY
G.C.
SLOPE FLOOR TILE TO DRAINS. SUBSTRATE MUST ALSO BE SLOPED TO DRAIN.
INSTALL SUSPENSION SYSTEM TO COMPLY WITH ASTM C 636, WITH HANGERS SUPPORTED ONLY FROM
BUILDING STRUCTURAL MEMBERS. LOCATE HANGERS NOT LESS THAN 6" FROM EACH END AND SPACE
4'-0" ALONG EACH CARRYING CHANNEL OR DIRECT-HUNG RUNNER. SECURE WIRE HANGERS BY LOOPING
AND WIRE TYING, EITHER DIRECTLY TO STRUCTURES OR TO INSERTS, EYE-SCREWS, OR OTHER DEVICES
WHICH ARE SECURE AND APPROPRIATE FOR SUBSTRATE.
D.
C.
ALL VCT SHALL BE CLEANED, SEALED, AND WAXED BY G.C. PRIOR TO TURNOVER.
D.
INSTALL POLYETHYLENE FILM ON CONCRETE SUBFLOOR.
SECURE MOUNTING BRACKETS TO STRUCTURE, SQUARE AND PLUMB, TO COMPLY WITH MANUFACTURER'S
INSTRUCTIONS.
C.
COMPLY WITH MANUFACTURER'S PRINTED INSTRUCTIONS AND WITH GOVERNING REGULATIONS,
FIRE-RESISTANCE RATING REQUIREMENT AND WITH INDUSTRY STANDARDS APPLICABLE TO THE WORK.
PREPARE SUBFLOOR OR EXISTING FLOOR SYSTEM AS RECOMMENDED BY MANUFACTURER.
C.
B.
FILL ALL CRACKS, JOINTS, ETC. IN SUB-FLOOR WITH CRACK FILLER APPROVED BY FLOORING
MANUFACTURER. INSTALL ALL MATERIALS WITH WATERPROOF TYPE ADHESIVES AS RECOMMENDED BY
FLOORING MANUFACTURER FOR MATERIALS AND SURFACES INVOLVED.
D.
C.
B.
B.
SUSPENSION SYSTEM AND ACOUSTIC PANELS AS LISTED ON REFLECTED CEILING PLAN SHEET AND
RESPONSIBILITY SCHEDULE.
COMPLY WITH ASTM C 635 FOR INTERMEDIATE - DUTY CLASS SYSTEM. SIZE ATTACHMENT DEVICES FOR
FIVE (5) TIMES DESIGN LOAD. HANGER WIRE SHALL BE GALVANIZED CARBON STEEL, ASTM A641, SOFT
TEMPER, PRE-STRETCHED, 12 GA MINIMUM.
GENERAL CONTRACTOR TO RECEIVE AND STORE MATERIAL. G.C. MUST OPEN BOXES A MINIMUM OF 48
HOURS IN ADVANCE OF INSTALLATION TO ACCLIMATE PRODUCT TO TEMPERATURE AND HUMIDITY OF
AREA TO RECEIVE INSTALLATION.
PART 2 - PREPARATION / EXECUTION
A.
INSTALL MOUNTING BRACKETS AT HEIGHTS TO COMPLY WITH APPLICABLE REGULATIONS OF GOVERNIN
AUTHORITIES.
B.
B.
A.
PART 2 - PREPARATION / EXECUTION
REFER TO SECTION 03732 "CONCRETE REPAIR / PREPARATION". AND TO SECTION 07200 "INSULATION AND
WATERPROOFING"
A.
PREP SLAB AS REQUIRED TO RECEIVE NEW VINYL TILE.
PART 1 - GENERAL
A. PROVIDE ACOUSTICAL PANEL CEILINGS WITH EXPOSED SUSPENSION GRID, AS SHOWN ON THE DRAWINGS.
PART 2 - PREPARATION / EXECUTION
A.
AT TIME OF COMPLETION, DELIVER TWO PACKAGES OF ACOUSTICAL PANELS TO THE TENANT OF EACH
TYPE OF MATERIAL USED, FOR FUTURE REPLACEMENT USE.
PART 2 - PREPARATION / EXECUTION
REFER TO SECTION 03732 "CONCRETE REPAIR / PREPARATION". AND TO SECTION 07200 "INSULATION AND
WATERPROOFING"
PHONE NUMBER: 650-654-7855
MATERIAL FOR INTERIOR STOREFRONT GLASS:
1.
B.
4. JOINTS BETWEEN BOARDS SHALL BE REINFORCED WITH TAPE EXCEPT WHERE CONTROL JOINTS ARE
REQUIRED. TAPE FIELD JOINTS, INTERIOR CORNER JOINTS AND WALL TO CEILING JOINTS. FILL JOINTS
WITH JOINT FILLING COMPOUND AND EMBED TAPE THEREIN. COVER TAPE WITH BEDDING
COMPOUND AND TAPER TO FEATHER EDGES. FILL SCREW HEAD DEPRESSIONS WITH JOINT FILLING
COMPOUND AND FEATHER THE EDGES. ALLOW TO DRY.
4000 Luxottica Place, Mason, OH 45040
a
FR I A R
PART 2 - PREPARATION / EXECUTION
a
SPECIFICATIONS
2 of 2
Date
07-01-16
Drawn By
LLB
Checked By
ANP
Sheet
G004
AREAS OF WORK
a
4000 Luxottica Place, Mason, OH 45040
p
+1 (513) 765-6000
a
6 Creamery Brook, East Granby, CT 06026
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Macy's Store Number: (687)
Revisions:
Mark
Date
1
By
07/07/16
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
FR I A R
Architect of Record
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
2016-026A
Seal
NAME:
GLENN S. YEAKEL
DATE:
07-01-16
REG NO:
20474
Engineer
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Seal
NAME:
DATE:
REG NO:
Nextore project
Number
1.
2.
"AREA OF WORK" SHOWN FOR REFERENCE ONLY;
REFER TO CONSTRUCTION PLANS FOR LEASE LINE
AND LIMITS OF WORK
ISSUED FOR:
THIS PLAN MAY NOT REFLECT ACCURATE EXISTING
CONDITIONS; REFER TO CONSTRUCTION PLANS
FOR EXISTING CONDITIONS
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
NORTH
1
73052
EXISTING MACY'S 1ST FLOOR PLAN
MACY'S
EXISTING
1ST FLOOR PLAN
SCALE: 1/4" = 1'-0"
Date
07-01-16
Drawn By
LLB
Checked By
ANP
Sheet
V100
a
4000 Luxottica Place, Mason, OH 45040
p
+1 (513) 765-6000
a
6 Creamery Brook, East Granby, CT 06026
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Macy's Store Number: (687)
Revisions:
Mark
Date
1
By
07/07/16
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
TING
06
(E)
RETAIL
(E)
2
14'-8"
6"
4
EXISTING TILE
FLOORING
TO REMAIN
EXISTING CARPET
TO BE DEMOLISHED
EXISTING CARPET
TO BE DEMOLISHED
8
EXISTING TILE
FLOORING
TO REMAIN
13
17'-4"
15
(E)
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
2
(E)
(E)
2016-026A
(E)
Seal
(E)
(E)
(E)
(E)
(E)
(E)
12
2
EX/D1
12
2
1
(E)
S
(E)
(E)
EXISTING CARPET
TO BE DEMOLISHED
(E)
(E)
3
101
Architect of Record
(E)
14
9
RETAIL
(E)
12
(E)
(E)
(E)
(E)
11
(E)
(E)
(E)
(E)
(E)
11
7
13
(E)
(E)
(E)
10
9
(E)
15
(E)
(E)
13
14
(E)
)
(E)
(R)
(E)
(R)
(E)
(E)
(E)
(E)
(E)
101
(E)
(E)
FR I A R
5
6
2
EXISTING EGRESS TO BE
MAINTAINED THROUGHOUT
CONSTRUCTION
7
6
(R)
(E)
EXISTING EGRESS TO BE
MAINTAINED THROUGHOUT
CONSTRUCTION
6
ALIGN
2
(D)
12
1
2
NAME:
GLENN S. YEAKEL
DATE:
07-01-16
REG NO:
20474
2
EXISTING TILE
FLOORING TO REMAIN
(E)
9
(E)
AREA C
AREA B
Engineer
12'-8"
NOTE: MACY'S RESPONSIBLE FOR REMOVING MACY'S
FIXTURES & MERCHANDISE, TYP.
1
DEMOLITION - FLOOR PLAN: AREA A
NORTH
2
SCALE: 1/4" = 1'-0"
NORTH
DEMOLITION - CEILING PLAN: AREA A
AREA A
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
KEYPLAN
SCALE: 1/4" = 1'-0"
Seal
KEY NOTES
1
1.
LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF CONSTRUCTION
2.
NOT IN CONTRACT; NO WORK IN THIS AREA, U.O.N.
3.
TEMPORARY BARRICADE TO BE PROVIDED BY G.C. PRIOR TO START OF ANY WORK; BARRICADE SHALL NOT IMPEDE CLEAR PATH OF EGRESS IN ANY WAY, AND SHALL REMAIN INTACT
THROUGHOUT DURATION OF WORK; UPON REMOVAL OF BARRICADE, G.C. TO PATCH, REPAIR AND RE-FINISH ANY DAMAGE CAUSED BY BARRICADE ATTACHMENT TO CEILING, FLOOR OR
ADJACENT WALLS; REF: BARRICADE DETAIL, AD100
4.
MACY'S RESPONSIBLE FOR REMOVING ALL FIXTURES, MERCHANDISE, GRAPHICS, ARTWORK AND ANY ASSOCIATED HARDWARE, WITHIN WORK AREA, U.O.N.; COORDINATE WITH MACY'S.
5.
EXISTING COLUMN WITH MIRROR FINISH TO REMAIN; PROTECT DURING CONSTRUCTION
6.
EXISTING WALL DISPLAY PANEL, STANDARDS AND WALL BASE TO BE REMOVED
7.
8.
1
9.
GENERAL NOTES
#
EXISTING MILLWORK DISPLAY SURROUND TO REMAIN; PROTECT DURING CONSTRUCTION; CLEAN SURFACE
A.
B.
C.
EXISTING P.O.S. FIXTURE TO BE REMOVED; COORDINATE REMOVAL AND RELOCATION OR DEMOLITION WITH MACY'S; REMOVE ALL ASSOCIATED POWER/DATA BACK TO THE SOURCE
EXISTING MACY'S FLOOR TILE TO REMAIN, TYP.
10. EXISTING CARPET TO BE REMOVED TO THE EXTENT SHOWN ON DEMOLITION PLAN; FLOOR SURFACE SHALL BE MADE LEVEL AND SMOOTH AND PREPARED TO RECEIVE NEW FLOOR FINISH
PER MANUFACTURER'S INSTALLATION RECOMMENDATIONS; REF: FINISH PLAN AND FINISH SCHEDULE
D.
E.
11. SEE MEP DRAWINGS FOR ADDITIONAL SCOPE OF MEP DEMOLITION THROUGHOUT THIS SPACE, TYP.
12. EXISTING GWB CEILING AND ACT SYSTEM TO REMAIN; ALL ASSOCIATED CEILING FIXTURES TO REMAIN U.O.N.; REF: MEP DRAWINGS
13. EXISTING MILLWORK DISPLAY SURROUND, SOFFIT AND FASCIA TO REMAIN; PROTECT DURING CONSTRUCTION AND INSTALLATION OF FIXTURES; CLEAN ALL SURFACES PRIOR TO
INSTALLATION OF FIXTURES
14. EXISTING SOFFIT LIGHT FIXTURES AND LENSES TO REMAIN; LIGHT BULBS TO BE REMOVED AND RETURNED TO MACY'S AND LENSES RE-INSTALLED.
15. SPRINKLERS THIS AREA SHALL BE RELOCATED, AND SUPPLEMENTED AS REQUIRED, TO MEET SPRINKLER REQUIREMENTS; REF: SPRINKLER SYSTEM NOTES,
SHEET A-102 AND MEP DRAWINGS FOR FURTHER INFORMATION
F.
G.
H.
THE G.C. SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE
PUBLIC AND/OR WORKMEN ON THE JOB AND TO PREVENT ACCIDENTS OR INJURY TO
ANY PERSON ON, ABOUT, OR ADJACENT TO THE PREMISES. THE G.C. SHALL COMPLY
WITH ALL LAWS, ORDINANCES, CODES, RULES AND REGULATIONS RELATIVE TO SAFETY
AND THE PREVENTION OF ACCIDENTS.
THIS DEMOLITION PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET OF
WORKING DRAWINGS. DO NOT REMOVE OR DEMOLISH ANYTHING WITHOUT VERIFYING
AND COORDINATING WITH ALL TRADES AS TO HOW THEY RELATE TO THE OVERALL
PROJECT.
THE G.C. SHALL BE RESPONSIBLE FOR REMOVING OR DEMOLISHING EXISTING
CONSTRUCTION WHICH WILL INTERFERE WITH THEIR NEW WORK AND ANY TEMPORARY
BRACING OR PERMANENT SUPPORT STRUCTURES.
WHEN EXISTING ELECTRICAL SERVICE, POWER, AND LIGHTING IS REMOVED, STUB BACK
AND CAP AS REQUIRED IN AREAS BETWEEN EXISTING CONDITIONS AND NEW WORK.
REMOVE EXISTING FLOORING MATERIAL, CAP EXISTING MECHANICAL, PLUMBING AND
ELECTRICAL SERVICES FLUSH WITH EXISTING SLAB AS REQUIRED, TYPICAL THROUGHOUT;
REFER TO RESPONSIBILITY SCHEDULE ON SHEET G002 FOR FLOORING PREPARATION.
AT THE G.C.'S OPTION, DEMOLISH OR REMOVE MORE OR LESS EXISTING WORK, PROVIDED
THAT SUCH VARIATION WILL EXPEDITE THE PROJECT AND NOT INCREASE THE EXPENSE
TO THE OWNER OR VIOLATE ANY CODES. THESE OPTIONS SHALL BE SUBJECT TO THE
LUXOTTICA'S PROJECT MANAGER'S APPROVAL.
COORDINATE ANY SYSTEMS SHUTDOWNS WITH LANDLORD & INCLUDE COSTS OF
SHUTDOWN IN THE BID.
EXCEPT AS NOTED, G.C. SHALL INCLUDE COSTS TO CUT, PATCH AND/OR REPAIR EXISTING
WORK AND EXISTING FACILITIES WHICH MAY BE DISTURBED DURING INSTALLATION OF
NEW WORK IN BID PACKAGES.
I.
J.
IN ACCORDANCE WITH THE DRAWINGS, THOSE ITEMS WHICH ARE REMOVED, AND ARE
NOT RELOCATED OR REUSED, SHALL BE DISPOSED OF BY THE G.C.; VERIFY WITH MACY'S
PRIOR TO DISPOSAL OF ANY DISPLAY FIXTURES, ARTWORK, OR ASSOCIATED HARDWARE.
ANY EXISTING RECEPTACLES TO REMAIN UNLESS NOTED OTHERWISE ON PLANS; REFER TO
ELECTRICAL DRAWINGS.
L.
REMOVE ALL WALL VINYL FROM WALLS (AS REQUIRED) AND PREP WALLS FOR NEW
FINISHES.
N.
86"
G.C. TO INSPECT ALL EXISTING WALLS TO REMAIN AND ENSURE THAT THEY ARE UP TO
CURRENT SPECIFICATIONS.
REMOVE WINDOW CRASH GRAPHICS
WALL RECEPTACLE
(@ 18"AFF U.O.N.)
TELEPHONE
ANY EXISTING DOORS AND FRAMES TO BE REMOVED UNLESS NOTED OTHERWISE ON
PLANS; REFER TO DOOR SCHEDULE.
K.
M.
SYMBOL LEGEND
FLOOR RECEPTACLE
TRACK
LIGHTING
RECESSED
LIGHT
S
(D)
FIXTURE TO BE
DEMOLISHED
DIRECTIONAL
LIGHT
SPRINKLER
HEAD
FIXTURE TO BE
RELOCATED
SECURITY
CAMERA
ILLUMINATED
EXIT SIGN
P.
NOT USED
Q.
SIGN CONTRACTOR SHALL REMOVE ALL SIGNAGE IN OLD (OR TEMPORARY) SPACE AT END
OF PROJECT, AS REQUIRED BY LEASE REQUIREMENT.
R.
NOT USED
S.
REMOVE ALL INTERIOR GRAPHICS AND WAYFINDING, TYPICAL IN ALL AREAS (RETAIL,
EMPLOYEE, OD). DO NOT REMOVE FROM LENS PROCESSING AREA.
TEMPORARY BARRICADE WALL
PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS
MEET, AND ARE IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE
LATEST EDITION OF TILE COUNCIL OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES,
CONTACT LUXOTTICA PROJECT MANAGER PRIOR TO INSTALLATION.
EXISTING ITEM TO REMAIN
DATE:
REG NO:
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
GRAPHIC LEGEND
DEMOLITION
FLOOR & CEILING
PLANS: AREA A
LEASE LINE; CONFIRM WITH CLIENT &
MACY'S PRIOR TO START OF WORK
EXISTING ITEM TO BE DEMOLISHED
73052
SPEAKER
(E)
(R)
B.O. CEILING
VERIFY IN FIELD
NAME:
Nextore project
Number
EXISTING FIXTURE
TO REMAIN
G.C. TO PROVIDE AND INSTALL TEMPORARY BARRICADE. REF THIS DRAWING FOR
INFORMATION
ZIPWALL FOAMRAIL
SPAN
@ CEILING &
WALLS
SUPPLY
AIR DIFFUSER
FLUORESCENT
STRIP LIGHT
O.
T.
RETURN
AIR GRILLE
2 x 2 LIGHT
FIXTURE
ZIPWALL DUST BARRIER SYSTEM
PROVIDED AND INSTALLED BY G.C.
G.C. TO VERIFY WITH SITE LOCATION
STORE OPERATIONS MATERIAL TO BE
USED. EITHER CLEAR PLASTIC OR
TARP (FIRE RETARDANT). VERIFY
CEILING FOR POLE SIZE REQUIRED.
Date
Sheet
Drawn By
ZIPWALL GRIPDISKS
LLB
BARRICADE DETAIL
N.T.S.
07-01-16
Checked By
REV 0.4
ANP
AD100A
a
4000 Luxottica Place, Mason, OH 45040
p
+1 (513) 765-6000
a
6 Creamery Brook, East Granby, CT 06026
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Macy's Store Number: (687)
Revisions:
Mark
Date
1
By
07/07/16
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
EXTG
VESTIBULE
N.I.C.
EXTG
STAIRS
EXTG
MECH
17
N.I.C.
N.I.C.
4
7
10
(D)
EXTG
MECH
EXTG
STAIRS
N.I.C.
N.I.C.
Architect of Record
2
EXTG
ELEV LOBBY
(R)
N.I.C.
11
12 13
18
2
FR I A R
14
6"
13
C
15
16
1
1
ASSOCIATES INC.
6
3
281 Farmington Avenue
Farmington, CT. 06032
6
2016-026A
EQ
2
2
(D)
(E)
Seal
(D)
5
4'-3"
4'-7"
(D)
(E)
1
2
9
DEMOLITION - FLOOR PLAN: AREA C
SCALE: 1/4" = 1'-0"
2
(R)
2
3
1
NORTH
2
NAME:
GLENN S. YEAKEL
DATE:
07-01-16
REG NO:
20474
(E)
(E)
EXTG
SALES AREA
EXTG
SALES AREA
N.I.C.
N.I.C.
Engineer
NOTE: MACY'S RESPONSIBLE FOR REMOVING MACY'S
FIXTURES & MERCHANDISE, TYP.
AREA C
AREA B
1
DEMOLITION - FLOOR PLAN: AREA B
NORTH
2
SCALE: 1/4" = 1'-0"
DEMOLITION - CEILING PLAN: AREA B
NORTH
SCALE: 1/4" = 1'-0"
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
AREA A
KEYPLAN
KEY NOTES
GENERAL NOTES
#
1.
LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF CONSTRUCTION
2.
NOT IN CONTRACT; NO WORK IN THIS AREA, U.O.N.
3.
TEMPORARY BARRICADE TO BE PROVIDED BY G.C. PRIOR TO START OF ANY WORK; BARRICADE SHALL REMAIN INTACT THROUGHOUT DURATION OF WORK; UPON
REMOVAL OF BARRICADE, G.C. TO PATCH, REPAIR AND RE-FINISH ANY DAMAGE CAUSED BY BARRICADE ATTACHMENT TO CEILING, FLOOR OR ADJACENT WALLS;
REF: BARRICADE DETAIL, AD100
4.
MACY'S RESPONSIBLE FOR REMOVING ALL FIXTURES, MERCHANDISE, GRAPHICS, ARTWORK AND ANY ASSOCIATED HARDWARE, WITHIN WORK AREA, U.O.N.; COORDINATE
WITH MACY'S.
5.
LINE OF NEW WALL CONSTRUCTION; COORDINATE LOCATION OF TEMPORARY BARRICADE WALL WITH NEW WALL CONSTRUCTION
6.
EXISTING WALL TO BE REMOVED IN ITS ENTIRETY, INCLUDING ALL ASSOCIATED STUDS, TRACKS, FINISHES AND RECEPTACLES; PATCH AND REPAIR WHERE DEMOLISHED
WALL MEETS EXISTING WALL TO REMAIN; MAKE SMOOTH, CONTINUOUS SURFACE; REMOVE ABANDONED RECEPTACLES, CIRCUITRY AND ALL ASSOCIATED WIRING AND
CONDUIT BACK TO SOURCE, TYP. U.O.N.
7.
CLEAN AND PREPARE ALL WALL SURFACES TO RECEIVE NEW FINISH PER MANUFACTURER'S RECOMMENDATIONS, TYP.
8.
NOT USED
9.
EXISTING CARPET FLOORING TO REMAIN; PROTECT DURING DEMOLITION AND CONSTRUCTION
10. NEW STOREFRONT SYSTEM TO BE LOCATED WITHIN EXISTING WINDOW OPENING IN THE MASONRY WALL; DEMOLISH EXISTING WINDOW, DEMOLISH MASONRY SILL AND
PREPARE OPENING TO RECEIVE NEW STOREFRONT SYSTEM; PROVIDE TEMPORARY SHORING AND/OR BRACING OF EXISTING WALL AS REQUIRED
A.
B.
C.
D.
E.
11. EXISTING CLEAN-OUT LOCATED IN FLOOR SLAB, TO REMAIN
12. PREPARE EXISTING CONCRETE FLOOR TO RECEIVE NEW FLOOR FINISH; ENSURE SURFACE IS LEVEL AND SMOOTH; PREPARE TO RECEIVE NEW FLOOR FINISH PER
MANUFACTURER'S INSTALLATION RECOMMENDATIONS; REF: FINISH PLAN AND FINISH SCHEDULE
F.
13. SEE MEP DRAWINGS FOR ADDITIONAL SCOPE OF MEP DEMOLITION THROUGHOUT THIS SPACE, TYP.
14. EXISTING FLUSH WALL PIPE PENETRATION, THIS AREA; MAINTAIN ACCESS
THE G.C. SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE PUBLIC
AND/OR WORKMEN ON THE JOB AND TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON
ON, ABOUT, OR ADJACENT TO THE PREMISES. THE G.C. SHALL COMPLY WITH ALL LAWS,
ORDINANCES, CODES, RULES AND REGULATIONS RELATIVE TO SAFETY AND THE PREVENTION
OF ACCIDENTS.
THIS DEMOLITION PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET OF WORKING
DRAWINGS. DO NOT REMOVE OR DEMOLISH ANYTHING WITHOUT VERIFYING AND
COORDINATING WITH ALL TRADES AS TO HOW THEY RELATE TO THE OVERALL PROJECT.
THE G.C. SHALL BE RESPONSIBLE FOR REMOVING OR DEMOLISHING EXISTING CONSTRUCTION
WHICH WILL INTERFERE WITH THEIR NEW WORK AND ANY TEMPORARY BRACING OR
PERMANENT SUPPORT STRUCTURES.
WHEN EXISTING ELECTRICAL SERVICE, POWER, AND LIGHTING IS REMOVED, STUB BACK AND
CAP AS REQUIRED IN AREAS BETWEEN EXISTING CONDITIONS AND NEW WORK.
REMOVE EXISTING FLOORING MATERIAL, CAP EXISTING MECHANICAL, PLUMBING AND
ELECTRICAL SERVICES FLUSH WITH EXISTING SLAB AS REQUIRED, TYPICAL THROUGHOUT; REFER
TO RESPONSIBILITY SCHEDULE ON SHEET G002 FOR FLOORING PREPARATION.
AT THE G.C.'S OPTION, DEMOLISH OR REMOVE MORE OR LESS EXISTING WORK, PROVIDED
THAT SUCH VARIATION WILL EXPEDITE THE PROJECT AND NOT INCREASE THE EXPENSE TO THE
OWNER OR VIOLATE ANY CODES. THESE OPTIONS SHALL BE SUBJECT TO THE LUXOTTICA'S
PROJECT MANAGER'S APPROVAL.
I.
J.
IN ACCORDANCE WITH THE DRAWINGS, THOSE ITEMS WHICH ARE REMOVED, AND ARE NOT
RELOCATED OR REUSED, SHALL BE DISPOSED OF BY THE G.C.; VERIFY WITH MACY'S PRIOR TO DISPOSAL
OF ANY DISPLAY FIXTURES, ARTWORK, OR ASSOCIATED HARDWARE.
ANY EXISTING RECEPTACLES TO REMAIN UNLESS NOTED OTHERWISE ON PLANS; REFER TO ELECTRICAL
DRAWINGS.
L.
REMOVE ALL WALL VINYL FROM WALLS (AS REQUIRED) AND PREP WALLS FOR NEW FINISHES.
WALL RECEPTACLE
(@ 18"AFF U.O.N.)
TELEPHONE
FLOOR RECEPTACLE
RETURN
AIR GRILLE
2 x 2 LIGHT
FIXTURE
TRACK
LIGHTING
FLUORESCENT
STRIP LIGHT
RECESSED
LIGHT
S
N.
REMOVE WINDOW CRASH GRAPHICS
(D)
FIXTURE TO BE
DEMOLISHED
DIRECTIONAL
LIGHT
SPRINKLER
HEAD
FIXTURE TO BE
RELOCATED
SECURITY
CAMERA
ILLUMINATED
EXIT SIGN
P.
NOT USED
Q.
SIGN CONTRACTOR SHALL REMOVE ALL SIGNAGE IN OLD (OR TEMPORARY) SPACE AT END OF
PROJECT, AS REQUIRED BY LEASE REQUIREMENT.
R.
NOT USED
S.
16. REMOVE MOTION SENSOR & SMOKE DETECTOR, THIS AREA; COORDINATE WITH MACY'S TO DETERMINE IF THESE ITEMS AND ANY ADDITIONAL CEILING EQUIPMENT NOT
SHOWN ON THIS PLAN, ARE TO BE SALVAGED OR DEMOLISHED.
COORDINATE ANY SYSTEMS SHUTDOWNS WITH LANDLORD & INCLUDE COSTS OF SHUTDOWN
IN THE BID.
REMOVE ALL INTERIOR GRAPHICS AND WAYFINDING, TYPICAL IN ALL AREAS (RETAIL, EMPLOYEE, OD).
DO NOT REMOVE FROM LENS PROCESSING AREA.
H.
EXCEPT AS NOTED, G.C. SHALL INCLUDE COSTS TO CUT, PATCH AND/OR REPAIR EXISTING
WORK AND EXISTING FACILITIES WHICH MAY BE DISTURBED DURING INSTALLATION OF NEW
WORK IN BID PACKAGES.
T.
PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEET, AND ARE
IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL
OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT LUXOTTICA PROJECT MANAGER PRIOR
TO INSTALLATION.
(R)
B.O. CEILING
VERIFY IN FIELD
NAME:
DATE:
REG NO:
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
GRAPHIC LEGEND
DEMOLITION
FLOOR & CEILING
PLANS: AREA B & C
LEASE LINE; CONFIRM WITH CLIENT &
MACY'S PRIOR TO START OF WORK
TEMPORARY BARRICADE WALL
Date
EXISTING ITEM TO REMAIN
EXISTING ITEM TO BE DEMOLISHED
73052
SPEAKER
(E)
G.C. TO PROVIDE AND INSTALL TEMPORARY BARRICADE. REF THIS DRAWING FOR INFORMATION
ZIPWALL FOAMRAIL
SPAN
@ CEILING &
WALLS
Nextore project
Number
G.C. TO INSPECT ALL EXISTING WALLS TO REMAIN AND ENSURE THAT THEY ARE UP TO CURRENT
SPECIFICATIONS.
O.
ZIPWALL DUST BARRIER SYSTEM
PROVIDED AND INSTALLED BY G.C.
G.C. TO VERIFY WITH SITE LOCATION
STORE OPERATIONS MATERIAL TO BE
USED. EITHER CLEAR PLASTIC OR
TARP (FIRE RETARDANT). VERIFY
CEILING FOR POLE SIZE REQUIRED.
SUPPLY
AIR DIFFUSER
M.
G.
18. PRIOR TO START OF CONSTRUCTION, G.C. TO PROVIDE BARRICADE AT AREA OF NEW STOREFRONT, IN COMPLIANCE WITH MALL MANAGEMENT REQUIREMENTS;
BARRICADE SHALL REMAIN INTACT THROUGH DURATION OF WORK; G.C. SHALL PATCH & REPAIR ANY DAMAGE CAUSED UPON REMOVAL OF BARRICADE
86"
EXISTING FIXTURE
TO REMAIN
15. OPEN TO DECK ABOVE; REMOVE LIGHT FIXTURES AS INDICATED ON PLAN AND RETURN TO MACY'S
17. PARTIALLY EXPOSED PIPE TO REMAIN
SYMBOL LEGEND
ANY EXISTING DOORS AND FRAMES TO BE REMOVED UNLESS NOTED OTHERWISE ON PLANS; REFER TO
DOOR SCHEDULE.
K.
Seal
Sheet
Drawn By
ZIPWALL GRIPDISKS
LLB
BARRICADE DETAIL
N.T.S.
07-01-16
Checked By
REV 0.4
ANP
AD100B
PRETEST
102
103
3
LCI-GH30
4
EQ112
7
8
7
SE-OD02
SE-OD03
SE-OD01-L
13 A200 11
12
10
00C
16 A200
N.I.C.
EXTG
ELEV LOBBY
3
107
GS-CW20
GS-CL02-R
13 A200 11
SK3
WAITING
LCI-GH30
GS-
EQ21
FE
12
GS-FN04
11
PW
GS-
G
RECESSED ELECTRIC PANEL
GS-PW10
OPTICAL
STATION
N.I.C.
104
GS
-PW
-FN
GS
14
1
0
A2
0
1
EQ
EQ22A
FRAME WARMER (HOT AIR)
USED
EQ100A
SINGLE POWER TABLE
USED
EQ100C
TRIPLE POWER TABLE
USED
EQ101
TONOMETER
USED
EQ102
AUTO-REFRACTOMETER
USED
EQ105C
FIELDS TESTER
USED
EQ108
PATIENT CHAIR
USED
EQ109B
REFRACTION STAND
USED
EQ112
STOOL
USED
EQ118C
CHAIR MOVER
Revisions:
Mark
EQ119
USED
CHART HOLDER
CHART HOLDER (WALL MOUNTED)
USED
SK3
SINK
USED
SK7
SINK
1
DESCRIPTION
USED
GS-FN07
STOOLS FOR SELECT TABLE
GS-FN04
LOUNGE CHAIR
REMARKS
USED
GS-FN08(A)(B)(C)
ADJ. TASK CHAIR("A"-HARD SURF. "B"-CARPET "C"-CALIFORNIA)
USED
GS-FN09
SIDE CHAIR
GS-FN09C
SIDE CHAIR (CALIFORNIA STORES)
GS-FN02(A)(B)(C)
ADJ. STOOL ("A"-HARD SURF. "B"-CARPET "C"-CALIFORNIA)
GS-FN05
SIDE TABLE (W/ GS-FN04 CHAIRS)
12
RETAIL
101
USED
GS-CW20
CASHWRAP, LC SIS
GS-CW20W
CASHWRAP, LC SIS (REQUIRES WIRING BY GC)
USED
GS-LF10
27" (H) JOJO
USED
GS-LF11
35" (H) JOJO
USED
GS-LF13
FRONT DOOR FOCAL
USED
W
70
-FN
GS
07
GS-LF53
GS-
1
GS-LF50
CAPACITY FIXTURE ENDCAP
GS-LF51
CAPACITY FIXTURE, 2-BAY
GS-LF52
CAPACITY FIXTURE, 3-BAY
GONDOLA MONITOR
GS-LF70
FITTING/SELECT TABLE
GS-LF70W
FITTING/SELECT TABLE (REQUIRES WIRING BY GC)
GS-LF71
FITTING/CASHWRAP
GS-LF71W
FITTING/CASHWRAP (REQUIRES WIRING BY GC)
GS-LF90
COLUMN PANEL, WITH BRAND MENU
BLOCKING
BLOCKING PROVIDED AND
INSTALLED BY G.C.
USED
GS-PW01A (L)(C)(R)
3 1/8" PERIMETER FIN ("L"=LEFT "C"=CENTER "R"=RIGHT)
USED
GS-PW10
48" (W) PERIMETER WALL UNIT
USED
GS-PW11
25" (W) PERIMETER WALL UNIT
GS-PW30
18" (W) MIRROR CABINET WITH STORAGE
GS-PW31
12" (W) MIRROR CABINET WITH STORAGE
GS-PW60
BACKWRAP FEATURE
GS-PW60_55
BACKWRAP W/ 55" DIGITAL MONITOR
GS-PW60_75
BACKWRAP W/ 75" DIGITAL MONITOR
GS-PW61
BACKWRAP FEATURE WITH SIGNAGE
GS-PW61_55
BACKWRAP FEATURE W/ SIGNAGE & 55" DIGITAL MONITOR
GS-PW61_75
BACKWRAP FEATURE W/ SIGNAGE & 75" DIGITAL MONITOR
GS-PW62
BACKWRAP FEATURE WITH WOOD FRAME
GS-PW62_55
BACKWRAP FEATURE W/ SIGNAGE, PORTAL FRAME, & 55" DIGITAL MONITOR
GS-PW62_75
BACKWRAP FEATURE W/ SIGNAGE, PORTAL FRAME, & 75" DIGITAL MONITOR
GS-PW80
FILLER WITH MIRROR, NO STORAGE
GS-PW81
PORTAL VERTICAL MODULE
GS-PW82
PORTAL HORIZONTAL MODULE
GS-PW83
WOOD FIN VERTICAL
GS-PW84
CORNER FILLER
GS-PW91
SERVICE TOTEM, WALL MOUNTED
GS-PW93
MIRROR, OVERALL SIZE MATCHES LF90/93
USED
GS-PW94
FRAME LEDGE, 26" W
USED
GS-PW95
FRAME LEDGE, 48" W
USED
BOH-UP24
UPPER CABINET
USED
GS-BOH01
WORK COUNTER FOR SIS
USED
GS-CL02
SINK BASE FOR SIS
USED
SE-CL03
CONTACT LENS STORAGE
USED
SE-OD01
DOCTORS DESK
USED
SE-OD02
SINK BASE
USED
SE-OD03
SINK CABINET ABOVE
GS-LF13
LCM-MW-CS
MAIN WALL CABINET SIGN
MAIN WALL CABINET SIGN
GENERAL NOTES
3.
DOCTOR'S EQUIPMENT (EQXXX); REFER TO RESPONSIBILITY SCHEDULE ON G002.
4.
COAT HOOK AT 54" TO CENTERLINE OF HOOKS.
5.
2A-10BC FIRE EXTINGUISHERS AS DIRECTED BY THE FIRE MARSHAL. (SUGGESTED LOCATIONS ON PLAN.)
6.
ROOM SIGNAGE TO BE MOUNTED 9" FROM EDGE OF DOOR FRAME HORIZONTALLY TO CENTER OF GRAPHIC & 5'-0" VERTICALLY FROM FLOOR TO CENTER OF
GRAPHIC. REF: ELEVATIONS.
A.
B.
C.
D.
E.
F.
G.
7.
COORDINATE MILLWORK SIZES, CONSTRUCTION & FINISHES WITH TENANT'S MILLWORKER; ALL FIELD COORDINATION TO BE VERIFIED PRIOR TO MILLWORK
FABRICATION; REF: ELEVATIONS FOR FURTHER MILLWORK INFORMATION; APPLY PAINTABLE CAULK WHERE MILLWORK MEETS WALL, TYP.
8.
INSTALL GS-PW FIXTURES SEQUENTIALLY STARTING AT THIS POINT. GC TO VERIFY ADJACENT WALL IS CLEAN, LEVEL, STRAIGHT AND PLUMB.
9.
DOCTOR'S CERTIFICATES/ LICENSES TO BE INSTALLED AT THIS LOCATION.
G.C. TO REFERENCE FIXTURE CONTRACTORS SHOP DRAWINGS FOR INSTALLATION INSTRUCTIONS FOR ALL FIXTURES,
WALL CABINETS, BASE CABINETS, AND COUNTERTOPS. G.C. TO COORDINATE WITH FIXTURE CONTRACTOR TO ENSURE
PROPER FIT OF ALL COMPONENTS.
G.C. TO ENSURE FIXTURES ARE PROTECTED DURING CONSTRUCTION.
G.C. TO PROVIDE ADEQUATE BLOCKING, AS REQUIRED, IN WALLS TO SUPPORT WALL CABINETS, FIXTURES &
ACCESSORIES.
G.C. TO FURNISH AND INSTALL LOCKSET OPERATIONAL BY TENANT ONLY.
G.C. TO SIGN FOR PACKAGES WITH A NOTE "SUBJECT TO CONCEALED DAMAGES" ON IT.
G.C. TO REFER TO GRAPHICS STANDARD MANUAL IN EVOCO FOR GRAPHIC MOUNTING HEIGHTS, TYPICAL.
E = EXISTING TO REMAIN
R = EXISTING TO BE RELOCATED
FUT= FUTURE EQUIPMENT
CAPACITY CALCULATIONS
FIXTURE TYPE
48" WALL FIXTURE
10. CHART HOLDER MOUNTED 1'-0" FROM DOOR EDGE TO CENTER OF HOLDER HORIZONTALLY, AND 3'-10" FROM FLOOR TO CENTER OF HOLDER VERTICALLY.
11. LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF CONSTRUCTION
12. NOT IN CONTRACT; NO WORK IN THIS AREA, U.O.N.
13. EXISTING COLUMN TO REMAIN
24" WALL FIXTURE
LCM-FW-CS
FOCAL WALL CABINET SIGN
LCM-EE-CS
EYE EXAMS CABINET SIGN
REMARKS
LCM-FW-CS.1
FOCAL WALL CABINET SIGN FOR 75” DIGITAL MONITOR BACK WRAP
USED
LCM-GR-32
ROOM ID SIGNS
USED
LCI-GH-30
OD SNAP FRAMES
USED
SE-GH-23
CERTIFICATE / LICENSE SNAP FRAMES
USED
LCM-GH-16
DOCTOR'S NAME SLAT SIGN
BLOCKING
based on REV 0.2
CAPACITY
TOTAL
3
69
207
FOR CLASS A, B AND C FIRES
STAPLES
(800) 333-3330
SIMPLEHUMAN QUICK LOAD PAPER TOWEL HOLDER
WALL MOUNT - STAINLESS STEEL - ITEM#180969 MDL:
KT1024
NONE
REFRACTION ROOM
PAPER TOWEL HOLDER - FREESTANDING
STAPLES
(800) 333-3330
SIMPLEHUMAN TENSION ARM PAPER TOWEL HOLDER
STAINLESS STEEL. ITEM#:180971 MDL#: KT1161
NONE
CONTACT LENS ROOM, OPTICAL STATION
COAT HOOK
GRAINGER
1-800-GRAINGER
10G182 POLISHED CHROME DOUBLE ROBE HOOK, MODEL
#01-9402,
NONE
OD ROOMS; INCLUDES MOUNTING HARDWARE
STAINLESS STEEL TRASH CAN
STAPLES
(800) 333-3330
SIMPLEHUMAN 16 GALLON BULLET
OPEN CAN #CW 1405 S.S.
NONE
REFRACTION ROOM
PAPER TOWEL HOLDER - WALL MOUNTED
WALL STANDARDS
BRACKETS
KNAPE & VOGT (OR
EQUAL)
KNAPE & VOGT (OR
EQUAL)
HEAVY DUTY STEEL STANDARD
NONE
#KV85ANO (DOUBLE SLOT), WHITE
HEAVY DUTY W/ LOCK NUT
NONE
#KV187ANO, WHITE
3/4" TH. X 12"D WHITE MELAMINE FINISHED ON
NONE
ALL SURFACES
SHELVING
GYPSUM BOARD
CERTAINTEED
ENDCAP
3
16
48
FIBERGLASS INSULATION
OWENS CORNING
2-BAY TABLE
0
92
0
CEILING ACCESS PANEL
WIND-LOCK
3-BAY TABLE
3
144
432
1
20
20
843
REMARKS
ALTERNATE
(800) 323-0620
136
850
MODEL #/COLOR
(800) 233-8990
(800) 872-5625
PROROC BRAND GYPSUM BOARD
NONE
LIGHT DENSITY FIBERGLASS BUILDING
INSULATION PRODUCTS
NONE
TR-AP024 24" X 24" ACCESS PANEL
NONE
DATE:
07-01-16
REG NO:
20474
Seal
NAME:
DATE:
PRO LINE #PR02-STCM
BRACKET 4T307
KIDDE / GRAINGER
PARTS OF AMERICA
34
TOTAL
NOTE: ALL SPECS MAY NOT BE USED IN EVERY STORE
GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS
LARSEN'S 800-633-6668 (MP
SERIES-MP5, W/B-2 WALL
BRACKET
FIRE EXTINGUISHER - MULTI-PURPOSE DRY
CHEMICAL TYPE: UL RATED 1-A 10-B/C, 5 LB
4
ENGATEMENT TABLE
14. EXISTING MILLWORK FASCIA AND LIGHTING LENSES TO REMAIN; PROTECT DURING INSTALLATION OF FIXTURES
QUANTITY
MISC.
OTHER
ARCHITECTURAL SPECIFICATIONS / FINISHES
ITEM / DESCRIPTION
MFG./PHONE #
GLENN S. YEAKEL
Engineer
REV 0.7
#
NAME:
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
DESCRIPTION
LCM-MW-CS.1
BLOCKING
Seal
COLUMN PANEL, WITH MIRROR
FIXTURE - FLOOR PLAN
CENTERLINE OF FIXTURE; G.C. RESPONSIBLE FOR CONTACTING MILLWORKER UPON ANY DISCREPANCY BETWEEN ACTUAL FIELD LOCATION OF CENTERLINE AND
WHAT IS INDICATED IN CONSTRUCTION DOCUMENTS.
CLIENT COMMENTS
281 Farmington Avenue
Farmington, CT. 06032
3" PERIMETER FIN ("L"=LEFT "C"=CENTER "R"=RIGHT)
NORTH
2.
07/19/16
ASSOCIATES INC.
GS-PW01 (L)(C)(R)
52
SCALE: 1/4" = 1'-0"
REMARKS
GS-LF93
GRAPHICS #
GRAPHIC PACKAGE ITEMS; REFER TO RESPONSIBILITY SCHEDULE ON G002 AND GRAPHICS SCHEDULES THIS SHEET FOR RESPONSIBILITIES. REFER TO INTERIOR
ELEVATIONS FOR MOUNTING DIMENSIONS AS APPLICABLE.
Description
SUBMIT FOR PERMIT
2016-026A
GS-LF53
SERVICE TOTEM, FLOOR FIXTURE
LF21
GS-LF11
GS-LF52
GS-LF53
SELECT BAR
GS-LF50
EASEL FIXTURE
USED
GS-LF50
GS-LF42
GS-LF92
LF10
07
-FN
GS
33" (H) ENGAGEMENT TABLE
GS-LF91
1
6"
GS-LF50
27" (H) ENGAGEMENT TABLE
GS-LF21
USED
USED
F
S- L
GS-LF20
USED
12
1.
By
07/07/16
Architect of Record
DESCRIPTION
USED
USED
1"
3'-5 2
-LF
GS
FIXTURE PLAN - KEY NOTES
Date
BLOCKING PROVIDED AND
INSTALLED BY G.C.
BLOCKING PROVIDED AND
INSTALLED BY G.C.
LCD SCREEN
USED
USED
"
6'-3 1_75
6
W
P
G S-
GS-
1
Macy's Store Number: (687)
USED
USED
14
5' -
12
01A_L
GS-PW
01A_CW01A_R
GS-PW
A_C W31 GS-P
1
0
W
GS-P
GS-P
07
G
A200
_L
01A
PW
GS-
_R
01A
PW
GS-
20W
CW
GS-
07
-FN
GS
11
2
2
EQ
14
6"
EXTG
SALES AREA
GS-PW01A_R
_R
01A
PW
GS-
_L
01A
PW
GS-
C
A_
01
5' -
GS-PW01A_L
-PW
GS
1
C
3
_
A
W
01 S-P
-PW G
S
G _L
A
01
1
W1
S- P
G
R
A_
01
W
P
S-
_75
W61
S -P
11
PW
"
5' - 0
10
-PW
GS
BOH-UP24
EQ6 EQ22A
12
G
BOH-UP24
EQ8C
7
11
BOH-UP24
15
11
GS-PW
10
GS-PW
3
5 A200 4
1
5
9
GS-FN04
GS-FN08B
12
8
106
GS-PW94
3
EYE NET STATION
USED
MILLWORK #
BOH-UP24
7
FRAME TRACER
EQ21
14
W91
N.I.C.
2"
GS-FN02B
EQ8C
USED
+1 (516) 393-2484
BLOCKING
GS-PW95
G S- P
NEW
STOCK
9
GS-FN08B
105
USED
GS-LF52
CONTACT
LENS
LENSOMETER (MANUAL)
LENSOMETER (AUTO)
N.I.C.
OPTOS
EQ100A
SE-TOWEL-C
BOH-UP24
EQ6
EQ6A
FURNITURE #
EXTG
MECH
EQ102
GS-FN08B
CASHWRAP
EQ6A
EQ101
EQ105C
USED
USED
REMARKS
+1 (513) 765-6000
p
5
EQ1
10
6
GS-FN02B
EXISTING EGRESS TO BE
MAINTAINED THROUGHOUT
CONSTRUCTION
9 A200 7
LCM-GR32
SE-GH-CHART
6
FE
1
GS-FN09
N.I.C.
GS-LF92
EQ109B
N.I.C.
LCI-GH30
LCI-GH16
EQ108
EQ119
EXTG
STAIRS
EXTG
VESTIBULE
1
DESCRIPTION
p
6 Creamery Brook, East Granby, CT 06026
FR I A R
EXAM
ROOM
EQUIPMENT #
4000 Luxottica Place, Mason, OH 45040
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
FIXTURE FLOOR PLAN - SCHEDULES
USED IN
PROJECT
a
a
REG NO:
Nextore project
Number
73052
ISSUED FOR:
REFER TO ELEV. FOR SIZE; PROVIDE BLOCKING AS REQUIRED
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
FIXTURE
FLOOR PLAN
SHELVING RATED AT 100 LBS.
FASTEN SHELVES TO BRACKETS (DOUBLE SLOTTED STANDARDS)
RETAIL SALES AREA
Date
07-01-16
Sheet
Drawn By
REV 0.3
LLB
Checked By
ANP
A100
KEY NOTES
GENERAL NOTES - CONSTRUCTION
EXAM
ROOM
PRETEST
102
103
EXTG
VESTIBULE
1
7
8'-0"
HOLD
V.I.F.
EXTG
STAIRS
N.I.C.
12'-0"
HOLD
4
1'-3"
EXTG
MECH
SE-OD02
1
4'-7"
EXTG
ELEV LOBBY
1
N.I.C.
107
5'-812"
C.
GC IS RESPONSIBLE FOR INSTALLING ALL FINISH FLOORING. GC IS ALSO RESPONSIBLE FOR ALL
FINISH WALL MATERIALS BEHIND AND UNDER ALL MILLWORK.
D.
GC SHALL SUPPLY AND INSTALL BLOCKING IN ALL WALLS AS REQUIRED TO SUPPORT WALL
SHELVING AND CABINETS. ANCHOR BLOCKING W/ SCREWS AT TOP MIDDLE AND BOTTOM (NO
SILICONE). REFER TO ELEVATIONS AND MILLWORK SHOP DRAWINGS FOR MOUNTING HEIGHTS.
103
F.
REFER TO SPECIFICATION G-00X SHEETS
G.
NO MATERIAL SUBSTITUTIONS WILL BE PERMITTED UNLESS SUBMITTED TO NEXTORE PROJECT
MANAGER FOR REVIEW AND APPROVAL.
H.
ALL MANUFACTURERS RECOMMENDED INSTALLATION AND MAINTENANCE PROCEDURES ARE TO
BE FOLLOWED BY GENERAL CONTRACTOR ON THIS PROJECT.
I.
GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE REPRESENTATIVE LISTED AS SOON
AS CONTRACTS ARE AWARDED TO COMMUNICATE DESIRED SCHEDULE DATES AND PROJECT
INFORMATION.
6
2
1
9
2
10
1
2
11"
12'- F.
V. I .
170*
V.I.F.
1'-5"
5
RETAIL
"
11
8'- I.F.
V.
K.
ANY QUESTIONS CONCERNING THESE SPECIFICATIONS SHALL BE DIRECTED TO THE PROJECT
MANAGER FOR DOCUMENT CLARIFICATION.
L.
ALL TENANT FURNISHED ITEMS (MATERIAL AND LABOR) TO BE SCHEDULED, COORDINATED &
SUPERVISED BY GC.
M.
FIRE MARSHAL TO DETERMINE FINAL LOCATION OF FIRE EXTINGUISHERS.
N.
ALL DIMENSIONS ARE TO FACE OF GYP. BD. UNLESS NOTED OTHERWISE ON PLANS.
O.
IN A REMODEL WHERE WALL COVERING IS TO BE REMOVED, SKIM AND FINISH WALL TO LEVEL 4
FINISH.
P.
ALL GYP. WALL BOARD TO BE FINISH LEVEL 4. CEILING GYP. TO BE LEVEL 5 FINISH.
Q.
PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEETS AND
ARE IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE
COUNCIL OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT NEXTORE PROJECT
MANAGER PRIOR TO INSTALLATION.
RECESSED ELECTRIC PANEL
2'-10"
N.I.C.
104
1
312"
2
2.
NOT IN CONTRACT; NO WORK IN THIS AREA, U.O.N.
3.
EXISTING WALL TO REMAIN, GC TO PATCH & REPAIR AS REQUIRED, TO RECEIVE NEW FINISH, TYP.
4.
WALLS TO RECEIVE NEW PAINT OR WALLCOVERING FINISH SHALL BE PREPARED TO LEVEL 4 FINISH; WALLS
TO RECEIVE TILE OR OTHER FINISH SHALL BE PREPARED PER FINISH MANUFACTURER'S RECOMMENDATIONS;
REF: FINISH SCHEDULE, INTERIOR ELEVATIONS & DETAILS FOR FINISH INFORMATION
5.
NEW ELECTRICAL PANEL; REF: ELECTRICAL DRAWINGS FOR MORE INFORMATION
6.
NEW PUMP AND 18"x18" ACCESS PANEL; REF: PLUMBING DRAWINGS FOR PUMP INFORMATION
7.
BUILD-OUT FURRED ENCLOSURE AS REQUIRED TO ENCLOSE EXPOSED PIPE
8.
ACCESS TO CLEAN-OUT IN FLOOR SLAB SHALL BE MAINTAINED
9.
NEW 6" ALUMINUM STOREFRONT SYSTEM TO MATCH EXISTING ADJACENT, SHALL MAINTAIN EXISTING
WALL RATING; CONFIRM IN FIELD; PROVIDE SHOP DRAWING SUBMITTALS FOR REVIEW AND APPROVAL.
LEVER
2'-6"
TO 3'-8"
1
A.
PREPARE / PATCH AND REPAIR SURFACES TO "LIKE NEW" CONDITION, (A LEVEL 4 FINISH) AND PREP
TO RECEIVE NEW PAINT AS SCHEDULED.
B.
G.C. TO VERIFY PROPER WORKING ORDER OF ALL EXISTING DOORS AND HARDWARE (WHICH ARE
DESIGNATED AS BEING RE-USED). REPAIR/REPLACE MATERIALS AS REQ'D.
C.
G.C. TO COORDINATE ALL EXISTING DOORS TO REMAIN WHICH WILL RECEIVE A NEW FINISH. THIS
INCLUDES DOOR REMOVAL, HARDWARE REMOVAL AND REPLACEMENT, SCUFFED/ SANDED /
APPLICATION OF NEW FINISHES AND RE-INSTALLATION.
D.
REFERENCE DOOR SCHEDULE THIS SHEET. VERIFY EXISTING HARDWARE AND SUPPLEMENT AS
REQUIRED. (EXAMPLE; IF CLOSER IS SCHEDULED, WHICH DOES NOT EXIST, A NEW CLOSER IS TO BE
INSTALLED IN ACCORDANCE WITH PROJECT SPECIFICATIONS.
E.
G.C. TO PROVIDE LOCK CYLINDERS COMPATIBLE WITH INSTA-LOCK CORES.
F.
VERIFY RE-KEYING REQUIREMENTS WITH NEXTORE CONSTRUCTION MANAGER PRIOR TO BID.
G.
WHERE NEW DOOR SLABS ARE TO BE INSTALLED, RE-USING EXISTING FRAMES, FIELD VERIFICATION
OF DOOR SLAB SIZE IS REQUIRED.
H.
NOT USED
I.
WHERE DOORS ARE EXISTING TO REMAIN, ANY KNOB HARDWARE IS TO BE REPLACED WITH
LEVER-STYLE HARDWARE; G.C. TO FIELD VERIFY.
281 Farmington Avenue
Farmington, CT. 06032
NO SCALE
DOOR WIDTHS AND HEIGHTS.
REQUIRED EXIT DOORWAYS ARE REQUIRED TO HAVE A CLEAR OPENING NOT LESS THAN 32 INCHES WIDE. FOR HINGED
DOORS, THE OPENING IS MEASURED WITH THE DOOR AT A 90 DEGREE ANGLE FROM ITS CLOSED POSITION. AT LEAST ONE
OF A PAIR OF DOORS, INCLUDING AUTOMATIC DOORS, HAS TO PROVIDE THE 32 INCH CLEAR OPENING. DOOR HEIGHTS ARE
REQUIRED TO BE A MINIMUM OF 80 INCHES.
HARDWARE.
HAND ACTIVATED DOOR OPENING HARDWARE IS REQUIRED TO BE CENTERED BETWEEN 30 AND 44 INCHES HIGH. LATCHING
AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL HAVE TO BE OPERABLE WITH A
SINGLE EFFORT BY LEVER TYPE HARDWARE, BY PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED
TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS ARE
REQUIRED TO OPERATE AT DESCRIBED ABOVE IN THE DIRECTION OF EGRESS.
CLOSERS.
THE MAXIMUM EFFORT TO OPERATE DOORS CANNOT EXCEED 8.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR
INTERIOR DOORS. REQUIRED FIRE DOORS MAY REQUIRED UP TO 15 POUNDS PRESSURE. THE PRESSURE IS TO BE MEASURED
AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING
DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE REQUIREMENTS. IF A DOOR HAS A CLOSER,
THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE
DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 INCHES (75 mm) FROM THE LATCH, MEASURED TO THE
LEADING EDGE OF THE DOOR.
HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS SHALL BE 44" A.F.F.
TO CENTERLINE.
DOOR TYPES
CASED OPENING
1
2
3
4
MODEL #/
COLOR
93K-7-R-15-D-STK
"CLASSROOM"
BEST ACCESS SYSTEMS
FINISH - US26D
BUTT HINGES (1-1/2 PAIR
FBB-179, 4-1/2" x 4-1/2"
STANLEY HARDWARE FINISH - US26D
PER DOOR)
#407-1/2" CONCAVE
WALL BUMPERS
IVES
ALUM SILVER
MFR.
DESCRIPTION
FLOOR STOPS
IVES
#436 ALUM SILVER
SOLID CORE WOOD
DOORS /
PL-LAM DOORS
COMMERCIAL DOOR
& HARDWARE
SEE DOOR SCHEDULE
HOLLOW METAL DOORS COMMERCIAL DOOR
& FRAMES
& HARDWARE
SEE DOOR SCHEDULE
ALTERNATE
SCHLAGE
REMARKS
KEY OPERATED ON OUTSIDE ONLY
ROOM NAME
SUBSTRATE ADHESIVE TO HAVE A VOC LIMIT
OF 30 g/L LESS WATER NO ADDED UREAFORMALDEHYDE RESINS FSC WOOD
2"
EXISTING MASONRY OPENING
V.I.F.
2"
DOOR WIDTH
DOOR HEIGHT
DOOR HEIGHT
DOOR HEIGHT
DOOR HEIGHT
REF: DOOR SCHEDULE
DOOR HEIGHT
REF: DOOR SCHEDULE
DOORS
WIDTH
BROOKLINE #1330A
1
2"
2"
2
3
KAWNEER
(770) 449-5555
HAGER HINGE CO.
(314) 772-4400
DETEX CORP.
(800) 729-3839
OLD CASTLE
(800) 222-1853
YALE COMMERCIAL
(800) 438-1951
STANLEY HARDWARE
(800) 622-4393
IVES
(877) 671-7011
SCHLAGE
(800) 847-1864
DESCO
(201) 568-4920
PACIFIC PRODUCTS
ALUMATEC
(877) 770-0181
COMMERCIAL DOOR
& HARDWARE
2784 NEWPORT HIGHWAY
SEVIERVILLE, TN 37876
(865) 429-8980
THE SLIDING DOOR
COMPANY
SHERYL HAI-AMI
(805) 497-8686
EXT 225
BEST ACCESS SYSTEMS
(317) 849-2250
NATIONAL GUARD
PRODUCTS INC.
(800) 647-7874
DOOR SIZE
HEIGHT THICK
FRAMES
DOOR DESCRIPTION
MATERIAL
FINISH
TYPE
07-01-16
REG NO:
20474
Engineer
GLAZING
LABEL
TYPE
MATERIAL
FINISH
P104
LABEL
NONE
HEAD
JAMB
DESCRIPTION
CLOSER THRESHOLD
NO
KICK
FLR
NO
101
3'-0"
6'-8"
1 3/4"
A
WOOD
PL105
NONE
NONE
1
HM
WAITING ROOM
102
3'-0"
6'-8"
-
B
ALUMINUM
CLR ANODIZED
TEMPERED
AS REQ'D
2
ALUMINUM
CLR ANODIZED
AS REQ'D 3/A101
DOOR TO MATCH EXISTING MACY'S VESTIBULE DOOR
LOBBY ENTRY
103
3'-0"
6'-8"
-
B
ALUMINUM
CLR ANODIZED
TEMPERED
AS REQ'D
3
ALUMINUM
CLR ANODIZED
AS REQ'D 3/A101
NEW STOREFRONT SYSTEM; DOOR TO MATCH EXISTING
MACY'S VESTIBULE DOOR
1/A101 LEVER/CLASS-RM
NO
STOP
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Seal
INSTA-KEY
(800) 316-5397
PEMKO MFG. CO.
(805) 642-2600
ALUMATEK
800-949-9950
KNAPP & VOGT
(800) 253-1561 OR
WWW.KV.COM
NAME:
DATE:
REG NO:
73052
REV0.1
REMARKS
HARDWARE
EXAM ROOM
- REFER TO PLAN FOR PROPER DOOR SWING DIRECTION
- ALL WOOD DOORS TO BE PROVIDED BY MILLWORKER, INSTALLED BY G.C.
DATE:
Nextore project
Number
WALL LEGEND
MARK
GLENN S. YEAKEL
EXIT DOORS, TOILET ROOM AND CHANGING ROOM DOOR TO BE OPENABLE FROM INSIDE WITHOUT SPECIAL
KNOWLEDGE, FORCE OR NEED OF KEY.
SEE SPECIFICATION SHEET FOR RESPONSIBILITIES.
ALL HARDWARE TO BE LEVER TYPE.
DOOR SCHEDULE
HAGER HINGE CO
BROOKLINE #1326-CV
CONCAVE
B
A
2"
1'-6"
STOREFRONT
2" 9" 2" DOOR WIDTH
1'-6"
HEAD - SLIDING DOOR
NOTE: ALL SPECS MAY NOT BE USED IN EVERY STORE GENERAL NOTE: FOLLOW ALL
MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS
2"
1'-6"
INTERIOR DOOR
DOOR HARDWARE SCHEDULE
2" DOOR WIDTH
2"
US
ED
O
T
3/4" HARDWOOD
PAINTED
7
8"
(1) LAYER GWB OVER HAT CHANNELS
REF: 3/A300 FOR WALL DETAIL
DOOR WIDTH
REF: DOOR SCHEDULE
2"
DOOR WIDTH
REF: DOOR SCHEDULE
3/4"
N
4
NAME:
DOOR HARDWARE MANUFACTURERS
EXISTING MASONRY OPENING
V.I.F.
3/4"
US
ED
WOOD TRIM. PAINT TO
MATCH ADJACENT WALL
DOUBLE UPPER TRACK.
PART OF JOHNSON
HARWARE SET 138F602D
FRAME TYPES
1
METAL STUD WALL WITH
PAINTED GYPSUM
BOARD BOTH SIDES
O
GWB (1) SIDE
REF: 4/A300 FOR WALL DETAIL
3
4"
CLIENT COMMENTS
DOORS
ENTRANCES.
ALL PRIMARY ENTRANCES TO BUILDINGS AND FACILITIES ARE REQUIRED TO BE MADE ACCESSIBLE. A PRIMARY ENTRANCE IS
DEFINED AS, "...ANY ENTRANCE TO A FACILITY WHICH HAS A SUBSTANTIAL FLOW OF PEDESTRIANS TO ANY SPECIFIC MAJOR
FUNCTION OF THE FACILITY." REVOLVING DOORS CAN NOT BE USED AS A REQUIRED ENTRANCE FOR THE HANDICAPPED.
RECESSED DOORMATS ARE REQUIRED TO BE ANCHORED TO PREVENT INTERFERENCE WITH WHEELCHAIR TRAFFIC.
2.
3.
T
DOOR: REFER DOOR
SCHEDULE
07/19/16
Seal
1.
NEW STOREFRONT
FRAME; REF: DOOR
SCHEDULE
Description
SUBMIT FOR PERMIT
2016-026A
SCALE: 1/4" = 1'-0"
N
3
METAL FRAME DOOR
JAMB
By
THRESHOLDS.
ALL DOOR THRESHOLDS SHALL COMPLY WITH LOCAL CODES, INCLUDING ACCESSIBILITY, TO MEET REQUIREMENTS FOR
"CHANGES IN LEVEL FLOOR SURFACE"; BEVEL OR SLOPE EXPOSED EDGE AT AN ANGLE NOT EXCEEDING 45 DEGREES, SO
THAT ALL VERTICAL CHANGES OF ELEVATION MEET SAID REQUIREMENTS.
FRAME DETAILS
3-5/8" STUD, GWB (1) SIDE
REF: 2/A300 FOR WALL DETAIL
Date
07/07/16
ASSOCIATES INC.
DOOR/HARDWARE DETAIL
ENTRANCE SIGNS.
ALL BUILDINGS ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY HANDICAPPED PERSONS SHALL BE
IDENTIFIED WITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, TO BE VISIBLE
TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS.
2
Macy's Store Number: (687)
90°
CONSTRUCTION - FLOOR PLAN
EXISTING WALL
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Architect of Record
NORTH
METAL STUD WALL WITH
PAINTED GYPSUM
BOARD BOTH SIDES
+1 (516) 393-2484
1
GENERAL DOOR NOTES
1
DBL 6" DP, 16 GA. BEAM
WITH 3 5/8", 18 GA.
TRACK TOP & BOTTOM
#10 SCREW @ 12" c/c,
TYP.
#10-24 X 1" LONG
SOCKET HEAD SCREW
+1 (513) 765-6000
p
Mark
2
3-5/8" STUD, GWB 2 SIDES
REF: 1/A300 FOR WALL DETAIL
p
6 Creamery Brook, East Granby, CT 06026
Revisions:
4
J.
1
4000 Luxottica Place, Mason, OH 45040
a
10. NEW GWB CONSTRUCTION (20 GA METAL STUDS @ 16" O.C. WITH 5/8" GWB ONE SIDE TO 6" ABOVE
FINISHED CEILING, STUDS CROSS-BRACED TO STRUCTURE ABOVE) TO ALIGN WITH FOOTPRINT OF EXISTING,
DEMOLISHED DISPLAY PANELS. PROVIDE IN-WALL BLOCKING; REF: A200.
2'-8"
1
WALL TYPES
a
CLEAR
2
1
LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF CONSTRUCTION
.F.
V. I
OPTICAL
STATION
1.
2
101
3"
EXTG
SALES AREA
8'-9"
V.I.F.
170
V.I . °
F.
ALIGN
3
ALIGN
2
GENERAL CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL UPCHARGES ASSOCIATED WITH THE
DELAY OF ORDERING SPECIFIED PRODUCTS.
8"
4'-612"
8'-1"
N.I.C.
106
1
4
EXISTING EGRESS TO BE
MAINTAINED THROUGHOUT
CONSTRUCTION
6'-5"
3'-3"
WAITING
4'-1"
105
SK3
4'-4"
GS-CL02-R
NEW
STOCK
1
BOH-UP24
3" V.I.F.
CONTACT
LENS
BOH-UP24
2'-3"
8
1
J.
C
1
ADEQUATE ACCESS PANELS OR DOORS SHALL BE INCORPORATED INTO TENANT WORK FOR
INSPECTION SERVICE AND REPLACEMENT OF BOTH LANDLORD AND TENANT EQUIPMENT,
COORDINATE PLACEMENT WITH LANDLORD'S ON-SITE REPRESENTATIVE.
2
N.I.C.
CASHWRAP
GC IS RESPONSIBLE FOR ANY PREPARATION OF THE FLOOR SLAB AND PROCUREMENT OF
MATERIALS REQUIRED AT THE PERIMETER TO PRODUCE A FLUSH CONDITION BETWEEN THE
LENSCRAFTERS FLOOR AREA AND THE EXISTING AREA FLOORING SURROUNDING.
9
2'-8"
V.I.F.
4
1
9
A400
9"
V.I.F.
B.
E.
N.I.C.
3"
V.I.F.
4
3
GC TO MAINTAIN ALL DIMENSIONS AS SPECIFIED. NOTIFY NEXTORE PROJECT MANAGER OF ANY
DISCREPANCIES OF HOLD DIMENSIONS.
FR I A R
A.
#
LEASE LINE; CONFIRM WITH CLIENT &
MACY'S PRIOR TO START OF WORK
EXISTING WALLS TO REMAIN, U.O.N.
EXISTING ITEM TO REMAIN, U.O.N.
NEW WALL
1
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
CONSTRUCTION
FLOOR PLAN
Date
07-01-16
Sheet
Drawn By
REV0.1
LLB
Checked By
ANP
A101
a
4000 Luxottica Place, Mason, OH 45040
p
+1 (513) 765-6000
a
6 Creamery Brook, East Granby, CT 06026
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
AC-4
C
10'-0"AFF
AC-4
C
10'-0"AFF
AC-4
10'-0"AFF
EXAM
ROOM
PRETEST
102
103
Macy's Store Number: (687)
EXTG
VESTIBULE
1
EQ
N.I.C.
Mark
4
(N)
AD
EQ
EQ
(N)
AD
N.I.C.
(N)
(N)
4
(N)
AD
(N)
AD-EM
9
N.I.C.
1
EXTG
ELEV LOBBY
CASHWRAP
107
N.I.C.
10'-0"AFF
(N)
4
CONTACT
LENS
(R)
WAITING
105
NEW
STOCK
X2
(N)
106
(E)
N.I.C.
5
(N)
AD
4
(N)
AD-EM
2
(R)
(N)
(N)
AD
EQ
EQ
1
(E)
(E)
(E)
7
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
C
10'-0"AFF
(E)
(E)
(E)
EXTG TO
REMAIN
11'-0"AFF
101
S
3
(E)
(E)
(E)
(E)
(E)
(N)
C
(E)
(E)
(E)
1
(E)
(N)
(E)
GS-LF53
3
EX/D1
(E)
2
EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR
TO NON-SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE,
IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION.
E.
WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, G.C. SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN
INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS
FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT
ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION.
F.
LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 101'-0" TO
150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE
#8 CONDUCTORS MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM.
G.
LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE THRU-WIRING WHEREVER POSSIBLE. MULTIPLE
CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE
ACCEPTABLE. LIGHTING FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE THRU-WIRING, ANY RELATED COSTS FOR MULTIPLE
CONNECTIONS SHALL BE INCLUDED IN BID.
(E)
(E)
07/19/16
CLIENT COMMENTS
NORTH
REFLECTED CEILING PLAN
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
2016-026A
Seal
G.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY LUXOTTICA. G.C. IS
RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER
DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, CONTRACTOR SHALL CALL THE LIGHTING
DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, G.C. SHALL CLOSELY
COORDINATE FIXTURE REQUIREMENTS WITH LUXOTTICA.
I.
EMERGENCY AND EXIT LUMINAIRES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST NATIONAL ELECTRICAL CODES. ALL
EMERGENCY AND EXIT FIXTURES SHALL BE DUAL-VOLTAGE WITH BATTERY BACKUP (120/277 VOLT INPUT). INSTALL A CENTRAL
BATTERY SYSTEM WHERE THE USE OF INDIVIDUAL BATTERY UNITS ARE PROHIBITED BY LOCAL CODES. IF PLAN LOCATION IS NOT
ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION.
J.
G.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM.
K.
G.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION.
L.
CEILING GRID SHALL BE CENTERED IN ROOM UNLESS OTHERWISE NOTED.
M.
DOWN LIGHTS SHALL BE CENTERED IN TILE UNLESS OTHERWISE NOTED.
NAME:
GLENN S. YEAKEL
N.
G.C. TO TIE INTO EXISTING HVAC SYSTEM AS SUPPLIED BY MACY'S; G.C. RESPONSIBLE FOR SUPPLYING AND INSTALLING ANY NEW
DUCTWORK OR MATERIALS ASSOCIATED WITH THE NEW LAYOUT, AND WILL BE RESPONSIBLE FOR BALANCING THE SYSTEM AS
REQUIRED BY MACY'S; REF: MEP DRAWINGS FOR MORE INFORMATION
DATE:
07-01-16
REG NO:
20474
O.
NO ITEM SHALL BE ATTACHED TO, OR SUSPENDED FROM, THE DECK ABOVE; NO PENETRATIONS SHALL BE MADE TO DECK ABOVE;
ALL EQUIPMENT, FIXTURES, ETC. SHALL BE ATTACHED TO TOP CHORD OF JOIST OR STRUCTURAL STEEL, TYP. U.O.N.
P.
HANGER WIRE AT SUSPENDED ACT CEILINGS SHALL BE 10 GA; AT SUSPENDED GWB CEILINGS SHALL BE 8 GA
Q.
ALL SUSPENDED CEILING SYSTEMS SHALL BE INSTALLED PER INDUCSTRY STANDARDS; ALL CODE REQUIREMENTS AND ALL
RECOMMENDATIONS OF THE MANUFACTURER SHALL BE MET.
R.
DIFFUSERS TO BE SUPPORTED BY HANG WIRES AT ALL (4) CORNERS, TYP.
A.
G.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD.
B.
EXISTING SPRINKLER HEADS SHOWN EXISTING TO REMAIN UNLESS NOTED OTHERWISE. CONTACT ARCHITECT / ENGINEER IF CHANGES
MUST BE MADE.
GS-LF53
(E)
Architect of Record
H.
2
(E)
1
D.
3
(E)
(E)
(E)
IT SHALL BE THE G.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE G.C. SHALL ALSO SHIP ANY
EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR.
2
(E)
(E)
(E)
3
C.
(E)
(E)
1
ALL NIGHT-LIGHT (NL) LUMINAIRES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING
(E)
EXTG TO
REMAIN
10'-5"AFF
(E)
6
(E)
C
(E)
B.
RETAIL
(E)
(E)
104
AC-4
(E)
(E)
3
OPTICAL
STATION
N.I.C.
(E)
(E)
(E)
EXTG
SALES AREA
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
EMERGENCY (EM) LUMINAIRES SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT" TO PROVIDE CONTINUOUS POWER TO BATTERY
PACK EVEN WHEN LUMINAIRE IS OFF.
(E)
(N)
AD
2
3
A.
2
8
4'-3"
V.I.F.
Description
SUBMIT FOR PERMIT
GENERAL NOTES - REFLECTED CEILING PLAN
EQ
(N)
AD
AC-4
7'-6"
V.I.F.
C
By
07/07/16
X2
(N)
EQ
(N)
Date
5
EXTG
MECH
EQ
EXTG
STAIRS
Revisions:
FR I A R
C
Engineer
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
SCALE: 1/4" = 1'-0"
Seal
MACY'S SYMBOL LEGEND
SYMBOL
2 x 2 LIGHT FIXTURES
SUPPLY AIR DIFFUSER
TYPE
AD
AD
RETURN AIR GRILLE
TRACK LIGHTING
AD- EM
FLUORESCENT STRIP LIGHT
SPEAKER
S
AD-EM
SECURITY CAMERA
RECESSED LIGHT FIXTURE
X2
X2
ILLUMINATED EXIT SIGN
SPRINKLER HEAD
2T-S
TL
DIRECTIONAL LIGHT
4T-S
CEILING LEGEND
TL
6T-S
TL
LEASE LINE
EXISTING CEILING
TO REMAIN, U.O.N.
NEW CEILING
(E)
EXISTING FIXTURE TO REMAIN
(R)
RELOCATED FIXTURE
KEY NOTES
LIGHTING SCHEDULE
REF: LIGHTING SCHEDULE FOR FIXTURE INFORMATION
8T-S
TL
(N) NEW FIXTURE
12T-S
TL
DESCRIPTION
RECESSED 2X2 LED TROFFER
SEE ELEC. SHEETS FOR MFG, SPECS ETC.
(TYP. ALL LIGHTS IN SCHEDULE)
RECESSED 2X2 LED TROFFER WITH EMERGENCY BATTERY
BACKUP.
2T-S
2 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
GIMBAL STYLE LAMP-HOLDER, WHITE
4T-S
4 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
GIMBAL STYLE LAMP-HOLDER, WHITE
6T-S
6 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
GIMBAL STYLE LAMP-HOLDER, WHITE
8T-S
8 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
GIMBAL STYLE LAMP-HOLDER, WHITE
12T-S
12 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
GIMBAL STYLE LAMP-HOLDER, WHITE
1.
LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF CONSTRUCTION
2.
NOT IN CONTRACT; NO WORK IN THIS AREA, U.O.N.
3.
EXISTING CEILING TO REMAIN; ALL FIXTURES TO REMAIN, U.O.N.
4.
NEW ACT CEILING SYSTEM; HEIGHT OF NEW CEILING TO BE FIELD VERIFIED PRIOR TO
INSTALLATION; REF: FINISH SCHEDULE FOR CEILING INFORMATION; REF: A300 FOR CEILING DETAILS
5.
RECESSED EXTRUDED ALUMINUM EDGE LIT EXIT SIGN WITH
RED LETTERS FOR CEILING OR WALL MOUNTING RED LED
INCLUDED. TO BE RECESSED MOUNTED U.N.O. (FOR NYC
OR CHICAGO CONFIRM WITH MANUF). PROVIDE
CURRENT LIMITER WHERE REQUIRED.
1
#
NEW ILLUMINATED EXIT SIGN TO COMPLY WITH ALL CODES; REF: MEP DRAWINGS FOR MORE
INFORMATION
6.
PLAN PROVIDES SUGGESTED SPRINKLER HEAD LOCATIONS; REF: SPRINKLER SYSTEM
NOTES BELOW AND MEP DRAWINGS, TYP.
7.
EXISTING MILLWORK FASCIA AND LIGHTING LENSES TO REMAIN; PROTECT DURING
CONSTRUCTION
8.
INFILL GWB CEILING TO MATCH EXISTING ADJACENT; PROVIDE SMOOTH AND CONTINUOUS
FINISHED SURFACE
9.
REF: P200 FOR SUGGESTED SPRINKLER LAYOUT
SPRINKLER SYSTEM NOTES
OD AREA ONLY
CONTRACTOR SHALL PROVIDE A COMPLETE FIRE PROTECTION SPRINKLER SYSTEM FOR THE ENTIRE SPACE IN
COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS AND THE LANDLORD'S CRITERIA. THE
CONTRACTOR SHALL HAVE DRAWINGS, SHOP DRAWINGS, APPLICATIONS AND SUBMITTALS PREPARED BY A
PROPERLY LICENSED PROFESSIONAL, WHO IS APPROVED BY THE LANDLORD. ALL DRAWINGS AND
CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL CODES, REGULATIONS, INSURANCE ASSOCIATIONS AND
RATING BUREAUS AND SHALL INCLUDE ALL PERMITS, TESTS, SHUT DOWN FEES AND CERTIFICATIONS TO
PROVIDE A COMPLETE IN PLACE SYSTEM.
NAME:
CONTRACTOR SHALL REWORK AND MODIFY THE SYSTEM IF NECESSARY FOR THE NEW SPACE CONFIGURATION.
MODIFICATIONS SHALL BE DESIGNED AND INSTALLED BY A QUALIFIED FIRE SPRINKLER CONTRACTOR, WHO
SHALL PREPARE DESIGN/SHOP DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS TO THE LANDLORD
AND BUILDING AND FIRE DEPARTMENTS FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. ALL
WORK SHALL BE DONE IN ACCORDANCE WITH NFPA, STANDARD 101, AND ANY OTHER STATE OR LOCAL CODES
HAVING JURISDICTION.
DESIGN STANDARDS:
MODEL 'G-4'; TYCO 'RF-11'
RELIABLE MODEL "G-F1'; TYCO 'TY-L'
RELIABLE MODEL "G"; 'TY-L'
WHITE CONCEALED HEADS; RELIABLE
RECESSED WHITE PENDANT HEADS WITH WHITE TRIM RINGS;
WHITE PENDANT HEADS WITH WHITE TRIM RINGS;
DATE:
REG NO:
Nextore project
Number
73052
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
REFLECTED
CEILING PLAN
Date
07-01-16
Sheet
Drawn By
REV0.2
LLB
Checked By
ANP
A102
C63
F
C63
B
WB101
B
WB101
W
P101
W
P101
EXAM
ROOM
PRETEST
102
103
EXTG
VESTIBULE
N.I.C.
P114
N.I.C.
F
C63
B
WB101
W
P101
CASHWRAP
3
107
EXTG
ELEV LOBBY
1
WALLS
3
N.I.C.
2
C
4
CONTACT
LENS
W
105
MFG./PHONE #
106
NEW
STOCK
5
3
N.I.C.
FLOORING
RETAIL
101
1
F
(800) 474-3794
PAINT
P104
PAINT (SEMI GLOSS) (EXTRA WHITE)
SHERWIN WILLIAMS
(800) 474-3794
PAINT
P114
PAINT (EGG SHELL)
SHERWIN WILLIAMS
(800) 474-3794
SW7066, GRAY MATTERS
NONE
PAINT
P117
PAINT (SATIN)
SHERWIN WILLIAMS
(800) 474-3794
SW7068 GRIZZLE GRAY
NONE
EXTG
SALES AREA
OPTICAL
STATION
N.I.C.
104
1
C63
B
WB101
W
P101
ET
RP
CA
W
NE ISH
FIN
NEW CARPET
FINISH
1
E
IN
TIL MA
ING RE
IST TO
E X OR
FLO
6
2
NONE
DOOR FRAMES EVERYWHERE
WALLCOVERING
WOLF GORDON INC.
HEIDI
SCHWARZINGER
REEF RFF 2557 VINYL WALLCOVERING WITH
OSNABURG BACKING - COLOR: ANCHOR
NONE
WALLCOVERING
WC106
WALLCOVERING
SOURCE ONE
CONTRACT
MIKE THOMPSON,
614-551-7928
TEXTURA STONE, COLOR: BLACK
DIMENSIONS: 12”X24”, 1-1/2” MM. THK.
NONE
6" H x 3/4"T PAINTED WOOD BASE
W/ 3/8" TOP CHAMFER
WB101
BASE
DWB101
MILLWORK WALL BASE
WOOD
WD201
CUSTOM WOOD MILLWORK
CHAIR RAIL
CR100
CHAIR RAIL
JOHNSONITE
CORNER GUARD
CG100
VINYL CORNER GUARD
JOHNSONITE
PORCELAIN TILE
PT105
PORCELAIN TILE (7 7/8" x 19 5/8" x 1/4" THK)
PORCELAIN TILE
PT108
LARGE FORMAT PORCELAIN TILE
24"x24"x10mm
PORCELAIN TILE
PT109
LARGE FORMAT PORCELAIN TILE
A.) 24"x24"x10mm #PFP2960
B.) 24"x6"x10mm #PFP2965
WOOD WALL BASE
NONE
MILLWORKER
MISSION OAK PANELING, LOW SHEEN
POLYURETHANE FINISH. 1/2" THICK BY 4-1/2"
WIDE
NONE
MOUNT OVER FIRE RATED PLYWOOD. SCHLUTER QUADEC @
OUTSIDE CORNER CONDITIONS.
CHR-50-C
NONE
OD WAITING, EXAM & PRETEST PER ELEVATIONS
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
[email protected]
50 WHITE
VBG-50-A-48
NONE
USE ON EXPOSED OUTSIDE CORNERS IN RETAIL (EXCEPT IN
STOREFRONT DISPLAY), O.D. & B.O.H.
ROBYN DUBEN
LOUISVILLE TILE
(866) 321-7385
WAY, WHITE
GROUT: 1/16" THK., MAPEI #38 AVALANCHE
NONE
STOREFRONT PORTAL FRAME, INSIDE WD201. VERIFY W
ELEVATION
TRANSCERAMICA
1159 W BRYN MAWR
ITASCA IL 60143
NOREEN SCHERTLER
(312) 342-4689
ROADS; ITEM #P66201 - SQUARE GREY CALM, (MATTE FINISH)
GROUT: 1/16" THK., MAPEI #27 SILVER (NO SUBSTITUTIONS)
NONE
MANDATORY INSTALLATION PER MANUFACTURER'S
SPECIFICATIONS.
TRANSCERAMICA
1159 W BRYN MAWR
ITASCA IL 60143
NOREEN SCHERTLER
(312) 342-4689
NEW GROUND; ANTHRACITE GROUND, (HONED FINISH)
GROUT: 1/16" THK., MAPEI #47 CHARCOAL (NO SUBSTITUTIONS)
NONE
JEFF TAYLOR (P):
(800) 241-4586
ROBERT SCHULER
(P): (800) 241-4586
STACKED MODULAR,
1404 STIMULATE 24x24 TILE
NONE
1404 STIMULATE; 24"X24" TILES
NONE
TERRA MAI
ATLAS CONCORDE
CARPET TILE 24"x24", ULTRA NYLON 6,6
J&J INVISION
CARPET TILE
C65
RUSTED MODULAR; MULTI-LEVEL TIP SHEARED
LOOP W NEXUS MODULAR BACKING
J&J INVISION
CEILINGS
AC-4
A-1
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
[email protected]
1774 DUNE TEGULAR, 2'x2'x5/8" ANGLED TEGULAR PRELUDE
15/16" EXPOSED TEE GRID SYSTEM
NONE
CLASS "A", REFERENCE "LUXOTTICA" AS ACCOUNT NAME
ALUMINUM
TIGER
(800) 898-4437
TIGER DRYLAC 49/80180
NONE
STOREFRONT GLAZING CHANNELS, 12' LENGTHS.
STOREFRONT BASE, & 2" REVEAL PROFILE.
NONE
MILLWORK
NONE
MILLWORK
NONE
MILLWORK
NONE
DOORS (BOTH SIDES)
NONE
MILLWORK
NONE
TRIM DETAIL FOR WALLCOVERING, 2-PART ASSEMBLY
NONE
MILLWORK
WILSONART
(800) 433-3222
PLASTIC LAMINATE
PL102
PLASTIC LAMINATE
FORMICA
MICHAEL HERTENSTINER
(440) 668-7030
PLASTIC LAMINATE
PL103
PLASTIC LAMINATE
FORMICA
MICHAEL HERTENSTINER
(440) 668-7030
FROSTY WHITE #1573-60 MATTE W/SOLID
COLOR CORE @ EXPOSED EDGES
DECOMETAL COLLECTION
2022 BRUSHED ALUMINUM
COLORCORE2 COLLECTION
7223C-58 NEW WHITE (MATTE)
PLASTIC LAMINATE
PL105
PLASTIC LAMINATE
WILSONART
(800) 433-3222
7964K-12 SKYLINE WALNUT
MILLWORK FINISH
PC100
MILLWORK POWDERCOAT
MATTHEWS PAINT
MP30136R11950 POWDERCOAT SOA V1.0
BRUSHED ALUMINUM
RECTANGULAR TRIM #110672 W/ BASE
#412007 FINISH - 120
S557 INTERNATIONAL WHITE / CRYSTAL
TEXTURE
ARCHITECTURAL
METAL TRIM
M102
MEL100
TS-1
METAL
STYLMARK
NADINE KING
(763) 574-7474
MELAMINE
PANOLAM
(800) 672-6652
TRANSITION STRIP (CARPET TO TILE)
JOHNSONITE
TRANSITION STRIPS
NORTH
FINISH PLAN
SCALE: 1/4" = 1'-0"
TS-2
TRANSITION STRIP (CARPET TO CONCRETE)
JOHNSONITE
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
PART # CCA-XX / #49 BEIGE
NONE
FLAME SPREAD: ASTME-84 75 OR LESS, CLASS B SMOKE
DEVELOP:NA, FUEL CONTRIBUTED: NA
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
PART # EG-XX-K / #49 BEIGE
NONE
FLAME SPREAD: ASTME-84 75 OR LESS, CLASS B. SMOKE
DEVELOP:NA, FUEL CONTRIBUTED: NA
SCHIENE, MINIMAL HEIGHT AS APPROPRIATE FOR FLOORING
TRANSITION ALUMINUM (-A); 1/4" THICK EDGE.
NONE
ZINC STRIP AT OD AREA.
PART # CTA-XX-K / #49 BEIGE
NONE
BETWEEN PORCELAIN TILE & VINYL
SCHLUTER - DECO, ALUMINUM (-A) HEIGHT AS APPROPRIATE
FOR FLOORING TRANSITION, 1/4" THICK ALUMINUM EDGE
NONE
STOREFRONT ENTRY BETWEEN RETAIL TILE AND MALL TILE
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
PART # RRS-XXC / #49 BEIGE
NONE
FLAME SPREAD: ASTME-84 75 OR LESS, CLASS B SMOKE
DEVELOP:NA, FUEL CONTRIBUTED: NA
[email protected]
TRANSITION STRIP
TRANSITION STRIP
TS-4
TRANSITION STRIP (CARPET TO VINYL AND
CARPET TO PORCELAIN)
TS-9
TRANSITION STRIP (PORCELAIN TO VINYL)
SCHLUTER
1-800-472-4588
WWW.SCHLUTER.COM
JOHNSONITE
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
TRANSITION STRIP
TS-10
TRANSITION STRIP (PORCELAIN TO MALL TILE SCHLUTER
1-800-472-4588
FLOORING)
WWW.SCHLUTER.COM
TRANSITION STRIP
TS-12
TRANSITION STRIP (VINYL TO CONCRETE)
XXXX
= BASE
W
XXXX
= WALL
T
XXXX
= TRIM
G.C. IS RESPONSIBLE FOR ANY PREPARATION OF THE FLOOR SLAB AND PROCUREMENT OF MATERIALS
REQUIRED TO PRODUCE A FLUSH CONDITION BETWEEN THE STORE LEASE LINE AND THE EXISTING
MALL FLOORING.
B.
G.C. IS RESPONSIBLE FOR INSTALLING ALL FINISH FLOORING. G.C. IS ALSO RESPONSIBLE FOR ALL FINISH
MATERIALS BEHIND AND UNDER ALL MILLWORK.
C.
1.
LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF CONSTRUCTION
2.
NOT IN CONTRACT; NO WORK IN THIS AREA, U.O.N.
3.
REFER TO ARCHITECTURAL SPECIFICATIONS, FINISHES SCHEDULE THIS SHEET & INTERIOR ELEVATIONS
FOR FURTHER INFORMATION
G.C. TO PATCH AND REPAIR EXISTING CONCRETE AS REQUIRED TO RECEIVE NEW FLOOR FINISH PER
MANUFACTURER'S RECOMMENDATIONS; COORDINATE WITH NEXTORE PROJECT MANAGER FOR
APPROVAL
4.
D.
ALL TENANT FURNISHED ITEMS (MATERIAL AND LABOR) TO BE SCHEDULED, COORDINATED AND
SUPERVISED BY G.C.
EXISTING CLEAN-OUT LOCATED IN FLOOR SLAB TO REMAIN; ENSURE NEW FLOORING INSTALLATION
ALLOWS FOR ACCESS
5.
E.
REFER TO ELEVATIONS FOR FINISHES WITH MORE THAN ONE DESIGNATION ON FINISH PLAN
NEW INFILL TILE AT AREA OF WALL DEMOLITION TO MATCH EXISTING, ADJACENT TILE; COORDINATE
WITH MACY'S
F.
REFER TO DOOR SCHEDULE FOR DOOR FINISHES.
6.
EXISTING TILE TO REMAIN
G.
PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEET AND ARE
IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL
OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT NEXTORE PROJECT MANAGER PRIOR TO
INSTALLATION.
H.
NOT USED.
I.
ALL FINISHED FLOOR SURFACES SHALL COMPLY WITH LOCAL CODES, INCLUDING ACCESSIBILITY CODES;
ANY CHANGES IN LEVEL FLOOR SURFACE SHALL COMPLY WITH ALL LOCAL CODES, INCLUDING
ACCESSIBILITY CODES.
1
2016-026A
Seal
LEASE LINE; CONFIRM WITH CLIENT &
MACY'S PRIOR TO START OF WORK
FLAME SPREAD
SMOKE DENSITY
PLASTIC LAMINATE
80 (BONDED)
95 (BONDED)
CARPET
26 - 75
450 OR LESS
VINYL TILE
0.45
450 OR LESS
LAY-IN CEILING
25
10
FRP
150
245
VINYL BASE
0.45
450 OR LESS
NAME:
GLENN S. YEAKEL
DATE:
07-01-16
REG NO:
20474
JOHNSONITE
TANDUS CENTIVA
OWNER FURNISHED
TRANSITION STRIP STYLE ME003 & ME004
LEVELER.
NONE
METAL EDGE TROIS(ME003) TRANSITION LVT TO CARPET, 12'
LENGTH. METAL EDGE QUATRE (ME004) - LEVELER ONLY (4'
STRIPS). INSTALL PER MANUFACTURER RECOMMENDATIONS
PRIMER/SEALER
LATEX PRIMER / SEALER FOR DRYWALL
ICI DULUX PAINTS
(502) 969-0181
# 1020-1200PVA
NONE
ONE (1) COAT REQUIRED
PRIMER/SEALER
LATEX PRIMER / SEALER FOR METAL
ICI DULUX PAINTS
(502) 969-0181
DEVGUARD #4120
NONE
ONE (1) COAT REQUIRED
PRIMER/SEALER
LATEX PRIMER / SEALER FOR WOOD
ICI DULUX PAINTS
(502) 969-0181
WOOD UNDERCOATER
NONE
ONE (1) COAT REQUIRED
CHROME
TS-13
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Seal
CHROME
CHR100
NAME:
DATE:
WALL LEGEND
MATERIAL
CLIENT COMMENTS
281 Farmington Avenue
Farmington, CT. 06032
CASING
T101
HARDWOOD CASING - PAINTED
3/4" x 3/4" HARDWOOD SQUARE
NONE
FINISH - P104
CASING
T102
HARDWOOD CASING - PAINTED
6 3/8" W x 3/4"T PAINTED HARDWOOD CASING
NONE
FINISH - P104
REG NO:
Nextore project
Number
REV0.7
INTERIOR MATERIALS FIRE RATINGS
07/19/16
Engineer
TRANSITION STRIP (LVT TO CARPET)
TRANSITION STRIP
SEALER
B
A.
#
TRIM
= FLOOR
KEY NOTES
Description
SUBMIT FOR PERMIT
ASSOCIATES INC.
MISC.
GENERAL NOTES - FINISH PLAN
By
[email protected]
[email protected]
FINISH SYMBOL KEY
Date
07/07/16
Architect of Record
MANDATORY INSTALLATION PER MANUFACTURER'S
SPECIFICATIONS.
MONOLITHIC INSTALLATION, INSTALL MUST INCLUDE MFG.
RECOMMENDED INSTALL METHOD, FLOOR PREP & ADHESIVE
INSTALL MUST INCLUDE MANUFACTURER’S RECOMMENDED
INSTALLATION METHOD, FLOOR PREP & ADHESIVE.
(800) 442-4212;
OPTION #1
PLASTIC LAMINATE
Mark
1
ARMSTRONG
PL100
Revisions:
FOR USE ON ROUND COLUMNS ONLY
2' x 2' LAY-IN; 15/16" GRID
PLASTIC LAMINATE
TRANSITION STRIP
XXXX
+1 (516) 393-2484
FINISH - P104
[email protected]
F
+1 (513) 765-6000
p
Macy's Store Number: (687)
LOCATION: REFERENCE ARCHITECTURE DRAWINGS FOR LOCATIONS & SEAMING.
NOTES: PRODUCT IS GLUED TO WALL WITH STANDARD POLYURETHANE ADHESIVE.
INSTALL TILES HORIZONTALLY.
MODEL/COLOR:
MANDALAY, MW-50-H6, 50 WHITE
C63
TRANSITION STRIP
1
p
6 Creamery Brook, East Granby, CT 06026
800 347 0550 X864; MOBILE 330 618 1296
[email protected]
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
[email protected]
JOHNSONITE
CARPET TILE
MELAMINE
6
INTERIOR WALLS AND SOFFITS
WC105
ALUMINUM
6
2
EXISTING TILE
FLOOR TO REMAIN
EXISTING TILE
FLOOR TO REMAIN
TS-4 0
40
8/A
F
NEW CARPET
FINISH
TS-4
8/A400
CEILING
2
3
NONE
WALLCOVERING
C63
MILLWORK
2
INTERIOR ACRYLIC LATEX
EXTRA WHITE, SW7006
INTERIOR ACRYLIC LATEX
EXTRA WHITE, SW7006
SHERWIN WILLIAMS
BASE
REMARKS
NOTE: ALL SPECS MAY NOT BE USED IN EVERY STORE
GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS
PAINT (EGGSHELL) (EXTRA WHITE)
2
TS-4
8/A400
ALT
P101
6
1
MODEL #/COLOR
PAINT
WAITING
P114
FINISHES
N.I.C.
P114
EXTG
MECH
W
XTG
TAIRS
4000 Luxottica Place, Mason, OH 45040
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
ITEM
MARK
DESCRIPTION
ARCHITECTURAL SPECIFICATIONS / FINISHES
W
a
a
FR I A R
F
EXISTING WALLS TO REMAIN
73052
1
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
NEW WALL
FINISH PLAN
PLANK/WOOD GRAIN DIRECTION, TYP.
Date
07-01-16
Sheet
Drawn By
LLB
Checked By
ANP
A103
EXISTING MILLWORK
FASCIA TO REMAIN,
PROTECT DURING FIXTURE
INSTALLATION
G.C. TO PROVIDE & INSTALL 1x6 FIRE-RATED WOOD BLOCKING BETWEEN STUDS IN
WALL BEHIND GWB, FOR WALL FIXTURE MOUNTING, AT LOCATIONS WHERE FIXTURES
ARE SHOWN, TYP.; REMOVE GWB, USE FASTBACK BACKING SYSTEM (CLARK DIETRICH)
IF REQUIRED, TO ATTACH TO EXISTING STUDS; PATCH & REPAIR WALL AFTER
BLOCKING INSTALLATION
ALL EXISTING
FINISHES TO
REMAIN
9'-612"
BOTTOM LIGHT LENS;
PROTECT DURING FIXTURE INSTALLATION
ALL EXISTING
FINISHES TO
REMAIN
a
4000 Luxottica Place, Mason, OH 45040
p
+1 (513) 765-6000
a
6 Creamery Brook, East Granby, CT 06026
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
OPEN
8'-11"
C.L. OF BLOCKING
Macy's Store Number: (687)
8'-11"
C.L. OF BLOCKING
10'-5"
EXISTING MILLWORK
DISPLAY SURROUND AND
BACKWALL TO REMAIN
EXISTING MILLWORK
FASCIA TO REMAIN,
PROTECT DURING FIXTURE
INSTALLATION
G.C. TO PROVIDE & INSTALL 1x6 FIRE-RATED WOOD BLOCKING
BETWEEN STUDS IN WALL BEHIND GWB, FOR WALL FIXTURE
MOUNTING, AT LOCATIONS WHERE FIXTURES ARE SHOWN,
TYP.; REMOVE GWB, USE FASTBACK BACKING SYSTEM (CLARK
DIETRICH) IF REQUIRED, TO ATTACH TO EXISTING STUDS; PATCH
& REPAIR WALL AFTER BLOCKING INSTALLATION
OPEN
Revisions:
17
A200
1
RETAIL 101
2
SCALE: 1/4" = 1'-0"
Mark
EXISTING DOORWAY TO
REMAIN (ACCESS TO
ELEVATOR LOBBY AND
NEW O.D. OFFICE)
EXISTING DOORWAY TO
REMAIN
RETAIL 101
Date
1
By
07/07/16
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
SCALE: 1/4" = 1'-0"
1
Architect of Record
1
P114
W
W
P101
P101
W
P101
W
P101
P101
W
FR I A R
W
REF: DOOR
SCHEDULE FOR
DOOR & FRAME
FINISHES
SE-CL03
SE-CL03
BOH-UP24 BOH-UP24
BOH-UP24 BOH-UP24 BOH-UP24
2'-5"
8"
24" x 24" x 1/8" PLEXI SHIELD
TO PROTECT WALL FROM
EQUIPMENT ARM SWING;
COORDINATE SIZE &
LOCATION W/ EQUIPMENT IN
FIELD; FASTEN TO STUDS OR
TOGGLE BOLT (4) SCREWS
V.I.F.
SNAP FRAME
B
WB101
B
B
2016-026A
4'-6"
1'-6"
WB101
281 Farmington Avenue
Farmington, CT. 06032
60" AFF
Seal
2'-6"
27" MIN
2'-10"
SE-CL02-R
ASSOCIATES INC.
LCI-GH30
GS-B0H01-R
2'-10"
52" AFF
1'-6"
GS-PW94
COAT HOOK;
REF: FIXTURE
SCHEDULE
B
WB101
WB101
B
WB101
WB101
B
REF: 4/A400, TYP.
CONTACT LENS 105
4
SCALE: 1/4" = 1'-0"
OPTICAL STATION 104
5
SCALE: 1/4" = 1'-0"
W
P101
CL
P114
W
2'-8"
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
1
1
W
P114
P101
W
P101
W
P101
W
P101
W
P101
W
P101
NAME:
GLENN S. YEAKEL
DATE:
07-01-16
REG NO:
20474
Engineer
FIRE EXTINGUISHER;
REF: FIXTURE
SCHEDULE
LCI-GH30
NEW DOOR/SIDELIGHT;
REF: DOOR SCHEDULE
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
LCI-GH30
3'-6"
6'-0"
ELECTRICAL OUTLET
34"
5'-9"
CL
CL
1'-6"
1'-6"
SE-OD01 _L
34"
T.O. SINK
27" MIN
34"
W
EXAM ROOM 102
7
4'-212"
ELEC. OUTLET
EQ-119
Seal
B
8
P114
SE-OD03
SINK 'SK-7'
RE: PLUMBING
DRAWINGS
EXAM ROOM 102
1
6'-6"
EQUIPMENT
SE-OD03
SCALE: 1/4" = 1'-0"
4'-9"
EQUIPMENT
CL
SE-OD03
6
1
1
W
CONTACT LENS 105
60" AFF
3
WB101
B
EXAM ROOM 102
9
SCALE: 1/4" = 1'-0"
WB101
B
EXAM ROOM 102
SCALE: 1/4" = 1'-0"
10
WB101
B
WB101
PRETEST 103
B
11
SCALE: 1/4" = 1'-0"
WB101
B
WB101
B
PRETEST 103/WAITING 106
WB101
12
SCALE: 1/4" = 1'-0"
B
WB101
B
WB101
PRETEST 103
SCALE: 1/4" = 1'-0"
NAME:
1
1
1
1
W
P101
W
P101
3"
78
EXISTING BRICK
WALL, TO REMAIN
REF: DOOR SCHEDULE FOR
DOOR & FRAME FINISHES
512"
NEW ELECTRICAL
PANEL; REF: ELEC.
DWGS.
SNAP FRAME
LCM-GH16
52" AFF
3'-10"
5'-0"
1'-0"
B
EQ
B
WB101
WAITING 106 / CASHWRAP 107
SCALE: 1/4" = 1'-0"
1 X CAT 6 HUBBELL HXJ6BK
1 X DUPLEX (BLACK)
GS-PW95
18" x 18" PUMP
ACCESS PANEL
14
SILL BELOW EXISTING
WINDOW REMOVED PER
CONSTRUCTION PLAN
EQ
WB101
WAITING 106
SCALE: 1/4" = 1'-0"
HILTI TOGGLER SNAP AWAY
TOGGLE BOLTS.
THROUGH PANEL AND GYP.
TYP. MIN. OF (4)
9'-6"
SE-GH-CHART
PROVIDE IN WALL (2) 34"
CONDUIT FROM
IN-WALL BOX TO 6" ABOVE
CEILING
NEW STOREFRONT SYSTEM
WITHIN EXISTING MASONRY
OPENING; REF: DOOR
SCHEDULE
FUTURE DISPLAY
MOUNTING
BRACKET
3'-6" AFF
LCM-GR32
13
REG NO:
DIM. TO LOCATE C.L.
P101
B
15
SCALE: 1/4" = 1'-0"
IN MILLWORK PANEL:
OUTWATER PLASTICS
INDUSTRIES INC.
OV32 SERIES GROMMET
PART#: OV32BK
1-800-631-8375
Nextore project
Number
73052
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
INTERIOR
ELEVATIONS
BASE CABINET PER ORIGINAL
DESIGN
GS-PW61_75 - TEMPORARY ELEVATION
WB101
OPTICAL STATION 104
IN WALL BEHIND MILLWORK
PANEL:
ARLTVBU505BL ARLINGTON™ TVBU505BL
TWO-GANG RECESSED
ELECTRICAL BOX (BLACK)
(OR EQUAL BLACK IN COLOR)
5'-63
4"
W
DATE:
EXISTING FASCIA
TRIM, TO REMAIN
Date
16
VESTIBULE ENTRY
SCALE: 1/4" = 1'-0"
17
FIXTURE GS-PW 61_75
SCALE: 1/4" = 1'-0"
07-01-16
Sheet
Drawn By
LLB
Checked By
ANP
A200
a
4000 Luxottica Place, Mason, OH 45040
p
+1 (513) 765-6000
a
6 Creamery Brook, East Granby, CT 06026
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Macy's Store Number: (687)
Revisions:
Mark
Date
1
By
07/07/16
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
FR I A R
Architect of Record
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
2016-026A
Seal
NAME:
GLENN S. YEAKEL
DATE:
07-01-16
REG NO:
20474
Engineer
EXISTING CEILING
REF: RCP FOR TYPE
& HEIGHT
CEILING
REF: RCP FOR TYPE
& HEIGHT
EXISTING CEILING
REF: RCP FOR TYPE
& HEIGHT
3 5/8" x 20 GA. METAL STUDS AT
16" O.C. w/ 5/8" TYPE "X" GYP. BD.
ONE SIDE; GYP. BD. & STUDS TO
UNDERSIDE EXISTING CEILING; CROSS
BRACE, AS REQUIRED
5/8" TYPE "X" GYP. BD. TO UNDERSIDE
OF EXISTING CEILING; ATTACHED
DIRECTLY OVER EXISTING WALL WITH
SCREW FASTENERS
CEILING
REF: RCP FOR TYPE
& HEIGHT
CEILING
REF: RCP FOR TYPE
& HEIGHT
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Seal
3 5/8" x 20 GA. METAL STUDS AT
16" O.C. w/ 5/8" TYPE "X" GYP. BD.
BOTH SIDES; EXTEND GYP. BD. TO
6" ABOVE FINISHED CEILING HEIGHT
ICC - ESR-3064
US
ED
7/8" HAT CHANNELS AT
16" O.C. w/ 5/8" TYPE "X" GYP. BD.
OVER; GYP. BD. & STUDS TO
UNDERSIDE OF EXISTING CEILING
6"
TYP.
PROVIDE STAGGERED CROSS
BRACING; 3‐5/8” 20 GA METAL
STUDS FROM TOP OF WALL
SECURED TO STRUCTURE ABOVE,
AT 24” O.C. MAX
O
T
NOTE: WALLS SHALL BE PLUMB
TO WITHIN 1/4" TOP & BOTTOM
AT MILLWORK LOCATIONS
EXISTING WALL
N
EXISTING WALL
NOTE: WALLS SHALL BE PLUMB
TO WITHIN 1/4" TOP & BOTTOM
AT MILLWORK LOCATIONS
NAME:
DATE:
REG NO:
Nextore project
Number
73052
ISSUED FOR:
BASE PER ROOM FINISH
SCHEDULE; REF: ELEVATIONS
BASE PER ROOM FINISH
SCHEDULE; REF: ELEVATIONS
BASE PER ROOM FINISH
SCHEDULE; REF: ELEVATIONS
BASE PER ROOM FINISH
SCHEDULE; REF: ELEVATIONS
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
WALL TYPES
4
WALL SECTION
SCALE: 3/4" = 1'-0"
7/8" FURRED WALL
3
WALL SECTION
SCALE: 3/4" = 1'-0"
GWB OVER EXISTING WALL
2
WALL SECTION
SCALE: 3/4" = 1'-0"
TYPICAL CHASE WALL
1
WALL SECTION
SCALE: 3/4" = 1'-0"
Date
TYPICAL FULL HEIGHT WALL
07-01-16
Sheet
Drawn By
LLB
Checked By
ANP
A300
a
4000 Luxottica Place, Mason, OH 45040
p
+1 (513) 765-6000
a
6 Creamery Brook, East Granby, CT 06026
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Macy's Store Number: (687)
1'-7"
PARTITION PER CONSTRUCTION PLAN
1"
4
1'-5" +/-
1"
FAUCET
WALL LINE
ACT CLG
3"
1'-54
CASED OPENING TRIM
PAINTED "P104"
3
TO TOP OF SINK
2'-10"
2'-3"
2'-5"
T
1'-3
"
PA N
EL H
1
HAND SINK DETAIL
3" SIGN CAB. THK.
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
Architect of Record
SCALE: 3/4" = 1'-0"
TRANSITION STRIP (TS-4) PER
PLANS AND SCHEDULES INSTALL
CARPET ON SUBFLOOR TO
ALIGN CARPET PILE HEIGHT WITH
ADJACENT FINISHED TILE
FLOORING
B.O. FINISHED CASED
OPENING:
9'-6 14" WHEN DOORWAY
ABUTTS TILED WALL,
9'-5 14" WHEN NOT
ABUTTING TILED WALL.
SEE CONSTRUCTION PLAN
A101 DOOR TYPES FOR
SPECIFIC HEIGHT
By
ADA SLOPED PANEL SINK BASE WITH
REMOVABLE PANEL. PROVIDE
CONCEALED SUPPORTS AND
FASTENERS AS REQUIRED
B.O. SIGN CABINET
8'-0"
11
2" 1"
Date
07/07/16
FR I A R
ALIGN TO BACKSIDE OF SIGN
CABINET:
1/2"THK X 1'-5 1/2"H x 2 1/2"W
PAINTED MDF
(EQ. THK. FILLER @ EA. SIDE BY GC)
FINISH P117
FINISHED OPENING BETWEEN
FILLERS SHALL BE 3'-11" HOLD.
1'-1"
T102
1'-5 1/4"
1'-512"
ILLUMINATED "EYE EXAM" SIGN
CABINET BY SIGN CONTRACTOR
(BACKSIDE)
Mark
REV0.1
6"
T
Revisions:
8"
9"
ACT CLG
3"
4 VARIES
B.O. O.D. CEILING
10'-0"
2'-6" C.L. A.F.F. IN WALL
6" FIRE-RATED WOOD BLOCKING
PROVIDED AND INSTALLED BY G.C.
314"
J-BOX ABOVE CEILING @ 10'-6" A.F.F.
BY ELECTRICAL CONTRACTOR WITH FLEX
CONDUIT WHIP ROUTED IN WALL THRU
CASING . SEE ELECTRICAL DRAWINGS
5"
112"
ADA, SS DROP-IN SINK
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
2016-026A
PORC. TILE ON THIN SET MORTAR BED
Seal
B
WB101
CORNERBEAD
GLUE DOWN CARPET PER
PLANS AND SCHEDULES
SECTION THRU - EYE EXAM SIGN
T
8
FLOOR TRANSITION DETAIL
SCALE: 6"=1'-0"
683"
SCALE: 1 1/2" = 1'-0"
WD201
T102
NEW PORCELAIN TILE
FLOORING PER PLANS
AND SCHEDULES
WOOD SURROUND AT LOCATIONS AS
INDICATED IN ELEVATIONS; 'WD201'
WOOD FINISH, PROVIDED BY TENANT;
CUSTOM FIT PROVIDED AND INSTALLED
BY MILLWORKER.
2
EXISTING TILE
4"
LINE OF SIGN
ABOVE
NAME:
GLENN S. YEAKEL
DATE:
07-01-16
REG NO:
20474
Engineer
REV 0.1
B
TS-10 TRANSITION
STRIP PER PLANS AND
SCHEDULES
B.O. CEILING
REF: RCP FOR TYPE & HEIGHT
6 3/8"W x3/4"T TRIM - PAINTED
P104 - GLUED & SCREWED. COUNTER SINK SCREWS,
FILL AND PREPARE FOR PAINT. PROVIDED AND
INSTALLED BY G.C.
SEE ELEVATION SHEETS A200 & A201
NON-COMBUSTABLE
BLOCKING
TS-4 CARPET TO PORCELAIN
W
W
T102
LINE OF EXTG. CONCRETE SLAB
4 7/8"
6
1/2" F.R. PLYWOOD SUBFLOOR-VERIFY
HEIGHT REQ'D IN FIELD
WB101
CASED OPENING - DETAIL
SCALE: 6"=1'-0"
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
ALIGN
PARTITION PER CONSTRUCTION PLAN
W
PT105
THIN SET MORTAR BED
PORCELAIN TILE & MORTAR
BED OVER GYP. BD.
NOTE: PREPARE EXISTING CONCRETE SLAB AS
REQUIRED TO PROVIDE LEVEL TRANSITION.
ILLUMINATED "LENS CRAFTERS"
SIGN CABINET BY SIGN
CONTRACTOR
J-BOX ABOVE CEILING @ 10'-6" A.F.F.
BY ELECTRICAL CONTRACTOR WITH FLEX
WHIP ROUTED IN WALL INTO SIGN
CABINET. SEE ELECTRICAL DRAWINGS
7
T102
PAINT EXPOSED
GYP. BRD.
WALL P101
FLOOR TRANSITION DETAIL
PORCELAIN TILE TO EXISTING TILE
SCALE: 6"=1'-0"
5"
8
T
B.O. CEILING
ACT @ 10'-0"
Seal
LINE OF EXISTING CONCRETE
SLAB
NAME:
3
4"
X 34" SQUARE TRIM PROVIDED
AND INSTALLED BY GC
PAINTED "P104"
3"
4
QUIRK
3
8"
B.O. TRIM
9'-6 1/4"
W
P104
T101
3/4"x3/4" SQUARE TRIM - PAINTED
P104 - GLUE & SCREW. COUNTER SINK
SCREWS, FILL AND PREPARE FOR PAINT.
PROVIDED AND INSTALLED BY GC.
SEE ELEVATIONS ON SHEET A200.
DATE:
REG NO:
Nextore project
Number
73052
ISSUED FOR:
LINE OF MILLWORK EDGE.
SEE ELEVATION SHEET A200 FOR
DIMENSIONS AND EXTENTS OF
MILLWORK
6"
RETAIL SIDE
O.D. SIDE
T
GS-PW81 WOOD FINISH.
CUSTOM FIT PROVIDED AND
INSTALLED BY MILLWORKER.
6"
6" WALL BASE
FINISH: P104
OUTLINE OF MILLWORK
FIXTURE BELOW.
5/8" GYP. W FINISH BEHIND
MILLWORK
PORCELAIN TILE
& MORTAR BED
OVER GYP. BD.
PROVIDED AND
INSTALLED BY G.C.
GS-PW82 WOOD SURROUND
ABOVE
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
FINISH FLOOR,
SEE SHEET A103
W
WD201
4"
SEE ELEVATION SHEET A200
FOR DIMENSIONS AND EXTENTS OF TILE
3"
4
1"
4
MISCELLANEOUS
SECTIONS &
DETAILS
Date
5
SECTION THRU - LENS CRAFTERS SIGN
SCALE: 1 1/2" = 1'-0"
4
WALL BASE DETAIL
SCALE: 6"=1'-0"
1
CUSTOM WOOD MILLWORK - SURROUND
SCALE: 6" = 1'-0"
07-01-16
Sheet
Drawn By
LLB
Checked By
ANP
A400
a
4000 Luxottica Place, Mason, OH 45040
p
+1 (513) 765-6000
a
6 Creamery Brook, East Granby, CT 06026
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Macy's Store Number: (687)
LOCATION OF EXISTING
SQUARE D, 208/120V,
225A PANEL
LOCATION OF PROPOSED
NEW LENS CRAFTERS PAD
Revisions:
Mark
Date
By
07/07/16
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
1
Architect of Record
1
FR I A R
3
4
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
2016-026A
Seal
NAME:
DATE:
REG NO:
Engineer
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Job# 2016128.00
Seal
PLAN NORTH
1
EXISTING FLOOR PLAN - FIRST FLOOR
SCALE: 1" = 40'-0"
XX
KEY NOTES - MECHANICAL/PLUMBING/ELECTRICAL OVERALL PLAN
1.
LOCATION OF SANITARY, VENT AND WATER. FIELD VERIFY LOCATION OF PIPING AND CONNECT TO NEW LC
MACY'S. CONTRACTOR IS TO SUGGEST ALTERNATE LOCATIONS IF THEY ARE DISCOVERED DURING
BIDDING/CONSTRUCTION.
2.
PLAN TO DROP THE SANITARY LINE IN ONE OF THESE LOCATIONS TO GET TO THE FIRST FLOOR LEVEL AND
CONTINUE TO THE TOILET ROOM DRAINS. VERIFY PIPE ROUTING AND LOCATION IN FIELD.
3.
UTILIZE EXISTING 225A PANEL FOR THE 60A FEED TO NEW LOAD CENTER "A" IN THE LENSCRAFTER'S SPACE.
VERIFY CURRENT LOAD ON PANEL AND REPORT TO ENGINEER TO CONFIRM PANEL CAPACITY.
4.
LOCATION OF EXISTING P.O.S. ROOM.
NAME:
Michael B. Walsh
DATE:
07/07/2016
REG NO:
123816
Nextore project
Number
MECHANICAL AND ELECTRICAL DRAWING INDEX
SHEET
MPE100
H100
H200
P100
P200
E100
E200
E201
E300
E400
DESCRIPTION
MECHANICAL AND PLUMBING OVERALL BUILDING PLANS
HVAC SPECIFICATIONS AND DEMOLITION PLAN
HVAC PLANS AND DETAILS
PLUMBING SPECIFICATIONS
PLUMBING PLANS AND DETAILS
ELECTRICAL SPECIFICATIONS, SYMBOLS AND DEMOLITION PLAN
ELECTRICAL POWER AND LOW VOLTAGE PLAN AND DETAILS
ELECTRICAL LIGHTING PLAN AND DETAILS
ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULE
CASEWORK DETAILS
73052
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
MECHANICAL AND
PLUMBING OVERALL
BUILDING PLANS
Title
Date
07-01-16
Sheet
Drawn By
GRD
Checked By
MTB
MPE100
STRUCTURAL ENGINEER.
GENERAL CONDITIONS, CODES & STANDARDS
I
1.
A.
4.
5.
6.
7.
8.
SCOPE OF WORK
1.
C.
A.
Mark
2.
3.
4.
5.
6.
7.
8.
GENERAL CONTRACTOR SHALL INCLUDE A VISIT TO THE JOB SITE AND TAKE INTO CONSIDERATION
MECHANICAL, ELECTRICAL AND GENERAL TRADE WORK CURRENTLY EXISTING AND WORK WHICH
MAY BE INSTALLED PRIOR TO CONTRACT AWARD. RELOCATION OF DUCTWORK, PIPING AND
EQUIPMENT, AS REQUIRED, TO AVOID THIS WORK SHALL BE PROVIDED AT NO ADDITIONAL COST TO
THE TENANT.
GENERAL CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE BUILDING SITE BEFORE STARTING
ANY FABRICATION OR DOING ANY WORK IN THE FIELD AND SHALL BE RESPONSIBLE FOR THE
CORRECT AND PROPER MEASUREMENTS OF HIS WORK ALONG WITH RESOLUTIONS FOR ANY
CONFLICT OF SPACE WITH OTHER TRADES.
WHERE THE WORK OF TWO OR MORE TRADES INTERFERE WITH EACH OTHER AND A DEVIATION
FROM DESIGN IS NECESSARY, NEITHER WORK SHALL PROCEED UNTIL THE TENANT HAS BEEN
NOTIFIED OF THE CONFLICT AND THEY HAVE RENDERED A DECISION AS TO WHAT CHANGES
SHOULD BE MADE.
GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE
REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE
PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF
DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE GENERAL CONTRACTOR CAUSING THE
DAMAGE.
IT IS ESSENTIAL THAT ALL WORK AT THE PROJECT BE DONE AS SUCH TIME AND IN SUCH MANNER AS
NOT TO INTERFERE WITH THE NORMAL OPERATIONS OF THE FACILITY. A WORK SCHEDULE SHALL BE
ARRANGED WITH THE TENANT TO FACILITATE WORK WITH A MINIMUM OF INTERFERENCE WITH THE
TENANT'S OPERATIONS.
AREAS TO BE USED FOR STORAGE SHALL BE ONLY AS DIRECTED BY THE TENANT. ALL STORED
MATERIAL SHALL BE RELOCATED OR REMOVED FROM THE SITE AS DIRECTED BY THE TENANT.
DAILY, AND AT THE COMPLETION OF THE WORK, EACH GENERAL CONTRACTOR SHALL REMOVE ALL
EXCESS MATERIALS AND DEBRIS CAUSED BY HIS WORK. UPON COMPLETION OF EACH GENERAL
CONTRACTOR'S WORK, CONDITIONS OF THE SPACE(S) SHALL BE THE SAME AS FOUND PRIOR TO
COMMENCEMENT OF THE WORK. FAILURE TO DO SO MAY RESULT IN THE TENANT'S EMPLOYMENT
OF A SEPARATE SERVICE TO OBTAIN THIS CONDITION AND REDUCING THE FACTOR'S CONTRACT
AMOUNT BY THE COST OF SUCH A SERVICE.
EACH GENERAL CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO OTHER WORK
CAUSED BY HIS WORK OR THROUGH THE NEGLECT OF HIS, OR HIS SUB-TRADE'S PERSONNEL. ALL
PATCHING, REPAIRING, REPLACEMENT AND PAINTING, ETC. SHALL BE DONE AS DIRECTED BY THE
TENANT BY THE CRAFTSMEN OF THE TRADES INVOLVED. THE COSTS OF SUCH WORK SHALL BE PAID
BY THE CONTRACTOR CAUSING THE DAMAGE.
By
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
AIR DISTRIBUTION
A.
XX
FR I A R
Architect of Record
KEY NOTES - MECHANICAL DEMOLITION PLAN
1.
REMOVE EXISTING SUPPLY AIR GRILLE OR DIFFUSER AS SHOWN.
2.
EXISTING SUPPLY AIR DUCTWORK TO REMAIN.
3.
EXISTING RETURN AIR TRANSFER GRILLE. SEE NOTE #3 ON SHEET H200.
4.
EXISTING SUPPLY AIR GRILLE OR DIFFUSER TO REMAIN.
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
2016-026A
Seal
CONTROL WIRING SHALL BE PLENUM RATED CABLE WITH COLOR CODED 18 AWG WIRES (MINIMUM).
EXTG
VESTIBULE
A.
TESTING AND BALANCING SHALL NOT BEGIN UNTIL THE SYSTEM HAS BEEN COMPLETED, IS IN FULL
WORKING ORDER AND ALL EQUIPMENT START-UP HAS BEEN COMPLETED. ALL HVAC SYSTEMS AND EQUIPMENT
SHALL BE PUT INTO FULL OPERATION AND THE OPERATION OF SAME CONTINUED DURING EACH WORKING DAY
OF THE TESTING AND BALANCING.
N.I.C.
B.
AN INDEPENDENT "AABC" OR "NEBB" CERTIFIED AIR AND WATER BALANCE CONTRACTOR SHALL TEST
AND BALANCE THE SYSTEM AND REPORT RESULTS TO THE ENGINEER TENANT AND THE LANDLORD.
1.
2.
3.
4.
5.
ALL WORK SHALL BE DONE UNDER DIRECT SUPERVISION OF THE CERTIFIED BALANCING ENGINEER
AND BY QUALIFIED BALANCING TECHNICIANS.
METHODS AND FORMS SHALL BE IN ACCORDANCE WITH THE CERTIFICATION AGENCIES
RECOMMENDATIONS AND REQUIREMENTS.
COMPLY WITH ASHRAE RECOMMENDATIONS PERTAINING TO MEASUREMENTS, INSTRUMENTS,
TESTING, ADJUSTING AND BALANCING.
ALL QUANTITIES SHALL BE WITHIN 10% OF THE DESIGN VALUES.
MECHANICAL CONTRACTOR SHALL PROVIDE ANY SHEAVE CHANGES REQUIRED ON THE HVAC UNIT.
TG
IRS
I.C.
EXTG
MECH
NAME:
N.I.C.
DATE:
EXTG
ELEV LOBBY
3
REG NO:
N.I.C.
4
4
C.
ACCEPTANCE AND CHECK-OUT - GENERAL CONTRACTOR SHALL PROVIDE QUALIFIED PERSONNEL, AT NO
ADDITIONAL COST TO THE TENANT, AS MAY BE REQUIRED BY THE ENGINEER FOR THE PURPOSE OF VERIFYING
PROPER OPERATION AND INSTALLATION OF THEIR WORK AT THE TIME OF
REQUEST FOR ACCEPTANCE.
4
Engineer
4
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Job# 2016128.00
1
1
Seal
2
2
EXTG
SALES AREA
2
2
2
N.I.C.
24"X20" SUPPLY
DUCT
@ 17'-0" A.F.F.
2
METHODS
1.
Date
07/07/16
1
COORDINATION
1.
E.
Revisions:
DUCTWORK (ROUND OR RECTANGULAR OR SPIRAL) SHALL BE OF GALVANIZED STEEL
CONSTRUCTION AND SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE
SMACNA MANUAL AND THE FOLLOWING PRESSURE / SEAL SCHEDULE:
1.1.
SUPPLY AIR DUCTWORK - 2" W.G. POSITIVE PRESSURE, SEAL CLASS B.
1.2.
RETURN & EXHAUST DUCTWORK - 2" W.G. NEGATIVE PRESSURE, SEAL CLASS B.
2. ROUND DUCT ELBOWS SHALL BE LONG SWEEP, 1-1/2 TIMES THE CENTERLINE RADIUS UNLESS
CLEARANCE IS NOT AVAILABLE AT WHICH TIME MITERED ELBOWS WITH TURNING VANES SHALL BE
UTILIZED.
3. RECTANGULAR ELBOWS SHALL BE FURNISHED WITH DOUBLE THICKNESS TURNING VANES. TURNING
VANES SHALL BE FASTENED WITH A DOUBLE ROW OF SCREWS.
4. MITERED OFFSETS GREATER THAN 30 DEGREES IN EITHER DIRECTION SHALL NOT BE PERMITTED.
5. CHANGES IN DUCT SIZES SHALL BE MADE BY UNIFORM TAPER SECTION WITH A MAXIMUM INCLUDE
ANGLE OF DIVERGENCE OF 15DEGREES.
6. RECTANGULAR BALANCING DAMPERS - RUSKIN MD25 SHALL BE SINGLE BLADE UP TO 6" IN HEIGHT
AND 36" IN WIDTH, AND RUSKIN MD35 MULTI-BLADE FOR LARGER SIZES. ALL ROUND BALANCING
DAMPERS SHALL BE COMMERCIAL GRADE SINGLE BLADE UP TO 16" IN DIAMETER SHALL
INCORPORATE LOCKING TYPE INDICATING ADJUSTMENT. BALANCING DAMPERS SHALL BE INSTALLED
IN ALL BRANCH DUCTS OFF MAIN AND ON ALL TAPS OFF DUCTS TO DIFFUSERS UNLESS OTHERWISE
NOTED ON DRAWINGS.
7. FINAL CONNECTIONS TO DIFFUSERS MAY BE MADE WITH FLEXIBLE DUCTWORK BUT IT'S USE IS
LIMITED TO STRAIGHT HORIZONTAL OR VERTICAL RUNS. ALL CHANGES OF DIRECTION IN AN DUCT
SYSTEM (GALVANIZED OR FLEXIBLE) SHALL BE MADE WITH AN APPROPRIATE GALVANIZED ELBOW.
MAXIMUM LENGTH OF ANY FLEXIBLE DUCT IS 5'-0".
8. FLEXIBLE DUCTS TO DIFFUSERS: MAXIMUM LENGTH OF FLEXIBLE DUCT TO DIFFUSER TO BE 5'-0".
9. SUPPORT ALL SHEET METAL AND EQUIPMENT FROM ANGLE IRON CONNECTED TO STRUCTURAL
STEEL. DO NOT SUSPEND DUCT OR EQUIPMENT FROM METAL DECK OR JOIST BRIDGING.
1.
D.
+1 (516) 393-2484
1.
DOCUMENTS
THE DRAWINGS ARE DIAGRAMMATIC, ALL WORK SHALL BE PERFORMED AS INDICATED ON THE
DRAWINGS UNLESS EXISTING CONDITIONS OR COORDINATION ISSUES REQUIRE CHANGES. THESE
CHANGES SHALL BE MADE WITH NO ADDITIONAL COST TO THE TENANT.
2. ANY INCIDENTAL ITEMS OR LABOR, ETC. NOT INCLUDED IN THE SPECIFICATIONS OR THE DRAWINGS
BUT REASONABLY IMPLIED AS NECESSARY FOR THE COMPLETE INSTALLATION OF ALL APPARATUS
SHALL BE INCLUDING IN BID.
3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY
MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED EVEN THOUGH NOT MENTIONED IN
BOTH.
4. IF ERRORS ARE FOUND IN THE DRAWINGS OR SPECIFICATIONS OR DISCREPANCIES OCCUR BETWEEN
THE SAME, OR BETWEEN THE FIGURES ON THE DRAWINGS, AND THE SCALE OF SAME OR BETWEEN
THE LARGER AND SMALLER DRAWINGS, OR IN THE DESCRIPTIVE MATTER ON THE DRAWINGS SHALL
BE REFERRED TO THE TENANT FOR REVIEW AND FINAL DECISION PRIOR TO THE BID DUE DATE.
5. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF EQUIPMENT AND MATERIALS EXACTLY
AS SPECIFIED HEREIN. WHERE MORE THAN ONE MANUFACTURER IS MENTIONED ANY ONE MAY BE
UTILIZED. SUBSTITUTE MANUFACTURERS MAY BE OFFERED ONLY AS AN ALTERNATE TO THE
SPECIFIED EQUIPMENT AND MATERIAL.
5.1.
SUBSTITUTIONS
5.1.1.
THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE CONTRACT DOCUMENTS
ARE FOR THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A BASE LEVEL OF QUALITY.
THE GENERAL CONTRACTOR'S BID WILL CONTEMPLATE THE USE OF THE EQUIPMENT AND
MATERIALS EXACTLY AS INDICATED.
5.1.2.
THE GENERAL CONTRACTOR SHALL SUBMIT FOR APPROVAL, WITH HIS BID QUOTATION, A
LIST OF ANY PROPOSED SUBSTITUTIONS OF MATERIALS AND EQUIPMENT FOR THOSE ON
WHICH THE ORIGINAL DESIGN WAS BASED. A FULL DESCRIPTION OF ALL PROPOSED
SUBSTITUTED ITEMS, THE CHANGE TO THEIR BID PRICE OR OTHER REASONS FOR SUCH
SUBSTITUTIONS SHALL ACCOMPANY THE BID. ALL ACCESSORIES, FEATURES, ETC.,
SUPPLIED WITH THE SUBSTITUTED MANUFACTURER'S PRODUCT SHALL ALSO BE INCLUDED
IN THE BID.
5.1.3.
IF THE GENERAL CONTRACTOR DOES NOT SUBMIT PROPOSED SUBSTITUTIONS WITH THEIR
BID THE TENANT SHALL CONSIDER THE BIDDER TO BE PROPOSING THE MANUFACTURERS
AND MODEL NUMBERS SPECIFIED HEREIN AND SHOWN ON THE CONTRACT DRAWINGS.
5.1.4.
SUBSTITUTIONS AFTER CONTRACT AWARD SHALL NOT BE PERMITTED.
6. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED
MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE
SPECIFICATIONS. REFER TO EACH SECTION FOR ANY SPECIFIC REQUIREMENTS.
+1 (513) 765-6000
p
10"∅
THIS CONTRACT SHALL INCLUDE THE FURNISHING, INSTALLING, CONNECTING, AND OPERATION OF
ALL EQUIPMENT WHICH IS A PART OF THE MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS
AND AS REQUIRED BY SIMILAR INSTALLATIONS. ANY MATERIAL OR LABOR WHICH IS NEITHER
SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY
NECESSARY TO COMPLETE THE WORK AND WHICH IS USUALLY INCLUDED IN WORK OF A SIMILAR
CHARACTER SHALL BE FURNISHED AND INSTALLED UNDER THIS CONTRACT AT NO ADDITIONAL
COST TO THE TENANT. GENERAL CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS
REQUIRED TO PROVIDE THE TENANT A COMPLETE, CODE APPROVED AND OPERATIONAL
MECHANICAL SYSTEMS.
2. CAREFULLY READ SPECIFICATION FOR ALL PARTS OF THE WORK SO AS TO BECOME FAMILIAR WITH
ALL TRADES' WORK SCOPE. CONSULT WITH OTHER TRADES TO INSURE PROPER LOCATIONS AND
AVOID INTERFERENCES. ANY CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE TENANT
BEFORE WORK IS COMMENCED.
3. ALL CONTRACTORS SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO
COMPARE THEM WITH THE DRAWINGS AND SPECIFICATIONS, NOTE THE EXISTING CONDITIONS AND
OTHER WORK THAT WILL BE REQUIRED, AND THE NATURE OF THE CONDITIONS UNDER WHICH THE
WORK IS TO BE PERFORMED. NO ALLOWANCE SHALL BE MADE TO ALL CONTRACTORS BY REASON
OF THIS FAILURE TO HAVE MADE SUCH EXAMINATION OR OF ANY ERROR ON HIS PART.
4. ALL EXISTING UTILITY AND MECHANICAL SERVICES SHALL BE FIELD VERIFIED. CORRECTIONS TO THE
DESIGN AND INSTALLATION SHALL BE MADE WITHOUT ADDITIONAL COST TO THE TENANT.
5. THIS GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE THE OPENINGS WITH THE GENERAL
TRADES CONTRACTOR. THE FINAL LOCATIONS AND SIZES OF ALL DUCT AND LOUVER OPENINGS
SHALL BE PROVIDED BY THIS CONTRACTOR.
6. THIS CONTRACT SHALL ALSO INCLUDE ALL LABOR, MATERIALS AND MISCELLANEOUS EXPENSES
REQUIRED FOR ALL REQUIRED MECHANICAL DEMOLITION OF THE EXISTING AREAS BEING
RENOVATED.
6.1.
ALL ABOVE GROUND SERVICES SHALL BE REMOVED BACK TO THEIR RESPECTIVE MAIN AND
CAPPED OR IF THE MAIN IS NOT REQUIRED, THE MAIN SHALL BE REMOVED IN IT'S ENTIRETY.
6.2.
COORDINATE ALL DEMOLITION WITH THE ARCHITECTURAL DOCUMENTS AND THE ARCHITECT
AND THE TENANT'S GENERAL REQUIREMENTS.
7. ALL WORK INCLUDING, BUT NOT LIMITED TO PARTS, MATERIAL, EQUIPMENT AND LABOR SHALL BE
GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE BY THE ENGINEER AND TENANT. WHERE AN
EQUIPMENT MANUFACTURER HAS A WARRANTY THAT EXCEEDS ONE YEAR, THAT WARRANTY PERIOD
SHALL APPLY TO THIS PROJECT.
p
6 Creamery Brook, East Granby, CT 06026
Macy's Store Number: (687)
12"∅
B.
2.
3.
INSTALLATION SHALL CONFORM TO THE MANUFACTURER'S RECOMMENDATIONS, AND IN
ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES.
CLEAN AND DRY SURFACES PRIOR TO INSULATING.
EXTEND INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, HANGERS AND SIMILAR
PENETRATIONS.
INSULATION JACKET AND FITTING COVER MUST BE PLENUM RATED.
IT IS ESSENTIAL THAT THE INTEGRITY OF THE VAPOR-BARRIER BE MAINTAINED. SEAL ALL
PENETRATIONS OF THE VAPOR BARRIER BY STAPLES, HANGERS OR WHERE OTHERWISE DAMAGED.
MAINTAIN ACCESS TO BALANCING DAMPERS AND VALVES.
INSULATION SHALL BE BY OWENS-CORNING, KNAUF, OR MANVILLE.
ALL DUCTWORK AND PIPING SHALL BE INSULATED PER REQUIREMENTS OF ASHRAE 90.1,
INTERNATIONAL ENERGY CONSERVATION CODE (IECC), NFPA, AND LOCAL CODES. THE FIRST 10 FEET
OF RETURN DUCTS SHALL BE INTERNALLY LINED FOR ACOUSTICAL ATTENUATION. OUTSIDE AIR
DUCTWORK AND DUCTWORK IN UNCONDITIONED SPACES SHALL ALWAYS BE INSULATED WITH
EXTERNAL INSULATION. PIPING SYSTEMS ALWAYS REQUIRING INSULATION INCLUDES, BUT IS NOT
LIMITED TO, CONDENSATE, REFRIGERANT, CHILLED WATER, HEATING HOT WATER, CONDENSER
WATER, AND STEAM. INTERNALLY INSULATED DUCTS SHALL HAVE 1 INCH THICK, 1-1/2 LB DENSITY
ACOUSTICAL INSULATION (AIR SIDE BLACK COATED TO MEET NFPA). INSULATION SHALL BE
INSTALLED PER THE REQUIREMENTS OF THE SMACNA GUIDE AND THE MANUFACTURER'S
RECOMMENDATIONS. DUCT SIZES NOTED ON DRAWING ARE INSIDE CLEAR DIMENSIONS.
INSULATION WRAP SHALL BE FIBERGLASS, FOIL BACKED WRAPPING. WHERE DUCTS OR PIPING IS
EXPOSED, AND REQUIRES INSULATION, PROVIDE FIBERBOARD RIGID INSULATION AND PAINT. PAINT
COLOR SHALL BE COORDINATED WITH THE ARCHITECTURAL DRAWINGS, LANDLORD, AND TENANT.
WHERE DUCTS OR PIPES ARE OUTSIDE THE BUILDING, AN ALUMINUM JACKET SHALL BE PROVIDED
AND INSTALLED OVER THE INSULATION, AND SEALED WEATHERTIGHT.
10"∅
4.
1.
4000 Luxottica Place, Mason, OH 45040
a
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
8"∅
3.
GENERAL
8"∅
2.
GENERAL CONDITIONS OF THE CONTRACT FOUND IN THE ARCHITECTURAL DRAWINGS, GENERAL
AND SPECIAL CONDITIONS OF THE AMERICAN INSTITUTE OF ARCHITECTS (AIA) (NSPE)(NEC) AND
ANY OF THE TENANT'S GENERAL REQUIREMENTS SHALL APPLY UNLESS NOTED OTHERWISE.
REFER TO THE GENERAL CONDITIONS ON THE ARCHITECTURAL DOCUMENTS AND THE GENERAL
AND SPECIAL CONDITIONS OF THE AIA FOR ADDITIONAL REQUIREMENTS REGARDING; SAFETY,
COORDINATION & COOPERATION, WORKMANSHIP, PROTECTION, CUTTING AND PATCHING,
DAMAGE TO OTHER WORK, PRELIMINARY OPERATIONS, STORAGE, ADJUSTMENTS, CLEANING, ETC.
ALL WORK SHALL BE IN CONFORMANCE WITH ALL LOCALLY ENFORCED, FEDERAL, STATE AND LOCAL
CODES AND ORDINANCES INCLUDING ANY SPECIAL THE TENANT REQUIREMENTS IN ADDITION TO
THOSE SPECIFIED.
GENERAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND
INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REQUIRED
COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS.
8"∅
A.
a
NAME:
Michael B. Walsh
DATE:
07/07/2016
REG NO:
123816
Nextore project
Number
73052
2
ISSUED FOR:
EQUIPMENT, PIPING, DUCTWORK, ETC. SHALL NOT BE SUPPORTED FROM ANY CEILINGS, OTHER
PIPING, CONDUIT OR DUCTWORK, ROOF DECK, OR JOIST BRIDGING. ITEMS SHALL BE SUPPORTED
FROM ACCEPTABLE STRUCTURAL BUILDING COMPONENTS AS DETERMINED BY THE ARCHITECT AND
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
HVAC
SPECIFICATIONS AND
DEMOLITION PLAN
Title
PLAN NORTH
1
MECHANICAL DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
Date
07-01-16
Sheet
Drawn By
GRD
Checked By
MTB
H100
TAG
SERVICE
MOUNTING
SUPPLY
AIR
SUPPLY
AIR
MATCH
CEILING
MATCH
CEILING
R1
RETURN
AIR
R2
RETURN
AIR
S1
S2
MFR
MODEL
No.
MODULE SIZE
FINISH
DUCT SIZE CROSS REFERENCE
TMS
24" X 24"
TITUS
TMS
12" X 12"
MATCH
CEILING
TITUS
50F
24" X 24"
STD. WHITE
FINISH
MATCH
CEILING
TITUS
50F
12" X 12"
STD. WHITE
FINISH
GENERAL NOTES - APPLIES TO ALL SHEETS
SUPPLY AIR DIFFUSER - ARROWS INDICATE
PATTERN. NO PATTERN SHOWN EQUALS 4-WAY.
OR AS NOTED
NOTES
STD. WHITE
FINISH
STD. WHITE
FINISH
TITUS
HVAC SYMBOLS
A.
RETURN AIR GRILLE
1
1
12"Ø
ROUND DUCTWORK. DIAMETER IN INCHES.
20x12
DIFFUSER/GRILLE LABEL:
A - TYPE/DESIGNATION
B - NECK SIZE (INCHES)
C - AIRFLOW (CFM)
B
C
A
B.
RECTANGULAR DUCTWORK. SIZE IN INCHES,
FIRST NUMBER IS SIDE SHOWN.
1. PROVIDE NECK SIZE TO MATCH SUPPLY DUCTWORK ON DRAWINGS.
POINT OF CONNECTION - NEW TO EXISTING
G.C. SHALL NOTIFY TENANT, ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR INCREASE THE
SCOPE OF WORK FROM WHAT IS DESCRIBED IN THE DOCUMENTS.
D.
G.C. SHALL BE RESPONSIBLE FOR ALL CUTTING/PATCHING RELATED TO THEIR WORK.
E.
IF SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM, CONSTRUCTION MATERIALS ABOVE
CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT
FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED TYPE PER NFPA 70.
F.
COORDINATE LOCATION AND ELEVATION OF MECHANICAL WORK WITH ALL DUCTWORK, LIGHT FIXTURES, AND
OTHER CEILING BUILT-IN FIXTURES. CONTACT ENGINEER OR ARCHITECT IMMEDIATELY SHOULD ANY CONFLICT
ARISE.
SHEET KEYNOTE REFERENCE
G.
KEY NOTES
#
1.
RETAIL AREA OPEN TO MACY'S HVAC SYSTEM. NO WORK REQUIRED IN THIS AREA.
2.
EXISTING SUPPLY AIR DUCTWORK TO REMAIN.
3.
EXISTING RETURN AIR TRANSFER GRILLE TO REMAIN IF LOCATED ABOVE NEW FINISHED CEILING IN RETURN AIR
PLENUM. IF NOT, CONTRACTOR SHALL RELOCATE TRANSFER GRILLE TO ABOVE NEW FINISHED CEILING.
4.
EXISTING SUPPLY AIR GRILLE OR DIFFUSER TO REMAIN.
5.
CONNECT NEW SUPPLY AIR DUCTWORK TO EXISTING STORE SUPPLY AIR DUCTWORK AS INDICATED.
6.
PROVIDE DAMPERS PER DETAIL C/H200.
7.
PROVIDE DUCT TAKE OFFS PER DETAIL. HIGH EFFICIENCY FITTINGS SHALL BE USED. SEE DETAIL A/H200
8.
CONTRACTOR SHALL VERIFY THAT A MINIMUM OF ONE 24X24 RETURN AIR OPENING TO THE CEILINGS RETURN
AIR PLENUM IS PROVIDED. IF ONE IS NOT PROVIDED, THE CONTRACTOR SHALL PROVIDE OPENING AS
INDICATED.
ECCENTRIC REDUCER
RECTANGULAR
DUCTWORK
ROUND
DUCTWORK
BALANCING
DAMPER
BALANCING
DAMPER
45° LATERAL FITTING
RECTANGULAR TO ROUND
"BUCKLEY FITTING"
RECTANGULAR
DUCTWORK
NO PVC PIPING ALLOWED IN PLENUM AREAS.
I.
DUCT SIZES INDICATED REPRESENT CLEAR INTERIOR SHEET METAL DIMENSIONS.
J.
ALL DUCTWORK CONCEALED ABOVE CEILINGS, AND ALL OUTSIDE AIR DUCTS, SHALL BE EXTERNALLY INSULATED.
IF DUCTWORK IS RUN IN A NON-CONDITIONED SPACE ALL DUCTWORK MUST BE INSULATED WITH 2" FIBERGLASS
INSULATION AND VAPOR BARRIER.
K.
BRANCH DUCTS SERVING DIFFUSERS SHALL BE SIZED TO MATCH DIFFUSER NECK SIZE INDICATED.
L.
ALL ROUND DUCT ELBOWS SHALL BE LONG SWEEP, 1-1/2 TIMES THE CENTERLINE RADIUS.
M.
G.C. MUST REPLACE ALL AIR FILTERS IN HVAC UNITS WITH NEW CLEAN FILTERS BEFORE AIR BALANCING AND
PRIOR TO FINAL TURNOVER TO TENANT.
N.
IT IS THE G.C.'S RESPONSIBILITY TO ENSURE THAT THE MECHANICAL COMPONENTS ARE INSTALLED AT
LOCATIONS AND ELEVATIONS WHICH MAKE THEM READILY AND SAFELY ACCESSIBLE FOR ROUTINE
MAINTENANCE WITHOUT REQUIRING ANY EXTRAORDINARY MEASURES.
O.
THE TENANT RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS AND SPECIFICATIONS.
SHOULD THE TENANT FIND CORRECTIVE WORK NECESSARY, HE WILL NOTIFY G.C. OF SUCH WORK IN WRITING
AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK IS DEEMED TO BE
NECESSARY, THE COST OF REINSPECTIONS WILL BE BORNE BY THE G.C. IF WORK IS REQUIRED BY TENANT IN
ORDER TO IMPROVE, CHANGE OR CORRECT AIR CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART
MALFUNCTION, WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE
STORE, G.C. SHALL BE DIRECTED BY TENANT TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES
EVIDENT THAT THE G.C. CAN NOT ACCOMPLISH THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE, THE
TENANT MAY AT HIS DISCRETION TAKE OVER SUCH WORK AND BACK CHARGE THE G.C. FOR ANY CORRECTIVE
WORK THAT WAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND/OR ADHERENCE TO PLANS
AND SPECIFICATIONS.
DUCTWORK SHALL NOT BE ROUTED OVER ELECTRIC PANELS AND TRANSFORMER.
Q.
INSULATE ALL DUCTWORK PER APPLICABLE ENERGY / MECHANICAL CODE - MOST RESTRICTIVE TO GOVERN.
EXTG
VESTIBULE
N.I.C.
p
+1 (513) 765-6000
6 Creamery Brook, East Granby, CT 06026
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Macy's Store Number: (687)
Revisions:
Mark
Date
By
07/07/16
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
1
Architect of Record
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
2016-026A
Seal
NAME:
BALANCING
DAMPER
S-1
150
CONICAL FITTING
TG
IRS
DUCT BRANCH TAKE-OFF DETAIL
I.C.
S-1
125
R-2
150
INSULATED RIGID ROUND
DUCTWORK. INSULATION TO
HAVE FOIL FACING (TYP.)
INSULATED FLEX. DUCT (5
FEET MAX.)
1'' DUCT LINER
LINE WITH 1" INSUL.
GALVANIZED SHEET
METAL DUCTWORK
SHALL BE 1.5 x R,
INSULATED 90 DEGREE
SHEET METAL ELBOW
VOLUME DAMPER TO
BE WITHIN 12" OF
MAIN DUCT
SEE DETAIL
B/H200
4
CONTACT
EXIST
LENS
150
GS-CL02-R
7
N.I.C.
CEILING DIFFUSER
HVAC DETAIL NOTES:
1
Seal
5
6
6
7
RETAIL
SEE HVAC DRAWINGS FOR DUCT
SIZES
101
8
EXTG
SALES AREA
N.I.C.
2
OPTICAL
STATION
2
2
10"∅
2
10"∅
2
8"∅
SCALE: NONE
1
8"∅
C
SCALE: NONE
DUCT CONNECTION DETAIL
8"∅
PLENUM RETURN BOX DETAIL
4
104
2
R SHALL EQUAL
OR BE GREATER
THAN 1/3W.
NAME:
Michael B. Walsh
DATE:
07/07/2016
REG NO:
123816
Nextore project
Number
24"X20" SUPPLY
DUCT
@ 17'-0" A.F.F.
73052
ISSUED FOR:
12"∅
W
R SHALL EQUAL
OR BE GREATER
THAN W.
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Job# 2016128.00
S-1
125
5
6
4
106
R-2
125
5
4
WAITING
8" DIA
6
N.I.C.
4
SEE DETAIL
B/H200
105
NEW
STOCK
1
R-2
250
SK3
DRAW BAND (TYP.)
ACOUSTICAL
CEILING
1.
8" DIA
SUPPORT TO
STRUCTURE
ABOVE (TYP.)
Engineer
EXTG
ELEV LOBBY
3
107
8" DIA
HIGH EFFICIENCY FITTING
N.I.C.
CASHWRAP
SCALE: NONE
REG NO:
EXTG
MECH
S-1
125
8" DIA
RECTANGULAR TO RECTANGULAR
R
4000 Luxottica Place, Mason, OH 45040
DATE:
SUPPLY AIR DUCT,
INSULATE PER SPEC.
B
a
a
ROUND
DUCTWORK
8" DIA
A
P.
4"
BRANCH DUCT HEIGHT
DIMENSION 2" LESS THAN
MAIN DUCT HEIGHT DIMENSION
BALANCING
DAMPER
MOUNTING OF ALL EQUIPMENT, DUCTWORK AND PIPING MUST BE DONE PER BUILDING GUIDELINES AND LOCAL
CODES AND INDUSTRY STANDARDS. COORDINATE INSTALLATION OF EQUIPMENT SUPPORT WITH BUILDING
MANAGER AND NEXTORE REPRESENTATIVE.
H.
VARIES
2" MINIMUM
COLLAR
EXISTING MECHANICAL INFORMATION IS BASED ON LIMITED EXISTING BUILDING DRAWINGS AND FIELD WORK.
THE G.C. SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY. NO ADDITIONAL COMPENSATION
SHALL BE ALLOWED FOR REVISIONS TO THE DESIGN TO CORRECT FOR EXISTING CONDITIONS NOT AS
INDICATED ON THE PLANS.
C.
MANUAL VOLUME DAMPER
#
THE CONTRACT DOCUMENTS REFLECT A SYSTEM DESIGNED AROUND SPECIFIC REFERENCE PRODUCTS, THE
SELECTION OF WHICH HAS IMPACTED THE DESIGNS OF OTHER TRADES. IF ALTERNATE MANUFACTURERS ARE
SUBMITTED OR BID, IT IS THE RESPONSIBILITY OF THIS G.C. TO COORDINATE ALL DIFFERENCES AND IMPACTS
WITH ALL TRADES PRIOR TO BID, INCLUDING COSTS ASSOCIATED WITH REQUIRED CHANGES TO OTHER TRADES.
NO EXTRAS WILL BE ALLOWED FOR CHANGES REQUIRED TO OTHER TRADES IF ALTERNATE EQUIPMENT IS BID OR
INSTALLED AT THE G.C.'S OPTION.
FR I A R
GRILLE, REGISTER AND DIFFUSER SCHEDULE
R SHALL EQUAL
OR BE GREATER
THAN 1/6W.
2
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
HVAC PLANS
AND DETAILS
STANDARD RADIUS ELBOW
D
RADIUS ELBOW DETAIL
SCALE: NONE
PLAN NORTH
1
HVAC DUCTWORK PLAN
SCALE: 1/4" = 1'-0"
Date
07-01-16
Sheet
Drawn By
GRD
Checked By
MTB
H200
GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE
INSTRUCTIONS.
PLUMBING EQUIPMENT SCHEDULE
DESCRIPTION
SINK: CLF-ADA-10
FAUCET: JUST # J-981
SK-7
30" SINK FOR BOH-SU30
T / PC
ELKAY
IWH-1A
IWH-1B
TANKLESS WATER HEATER MOUNTED BELOW SINKS IN
CABINET.
PC / PC
EEMAX
MODEL #SP2412
SINGLE POINT, 120 VOLT, 1 PHASE, 60 HZ, 2.4 KW, 33° TEMPERATURE
RISE.
SEP-1
SEWAGE EJECTION PUMP AND RESERVOIR
PC / PC
SANIFLO
SANIVITE
SELF CONTAINED SEWAGE EJECTOR PUMP AND BASIN. CORD AND PLUG CONNECTION TO GFI OUTLET
REQUIRED. 120V, 4.5 AMPS, 3/10 HP. UNIT IS APPROXIMATELY15" X 8" X 11" HIGH (WITHOUT PIPING).
PROVIDE SANIALARM WITH UNIT AND INSTALL. PURCHASE PUMP FROM SELECTED VENDOR: SANIFLO,
DISTRIBUTER TO CONTACT: THE DISTRIBUTION POINT (ALABAMA). CONTACT NAME: ROB FOSTER; CONTACT
PHONE: 1-866-837-2550; CONTACT EMAIL: [email protected] OR
[email protected]
T / PC
GENERAL CONDITIONS, CODES & STANDARDS
2.
3.
4.
GENERAL CONDITIONS OF THE CONTRACT FOUND IN THE ARCHITECTURAL DRAWINGS, GENERAL
AND SPECIAL CONDITIONS OF THE AMERICAN INSTITUTE OF ARCHITECTS (AIA) (NSPE)(NEC) AND
ANY OF THE TENANT'S GENERAL REQUIREMENTS SHALL APPLY UNLESS NOTED OTHERWISE.
REFER TO THE GENERAL CONDITIONS ON THE ARCHITECTURAL DOCUMENTS AND THE GENERAL
AND SPECIAL CONDITIONS OF THE AIA FOR ADDITIONAL REQUIREMENTS REGARDING; SAFETY,
COORDINATION & COOPERATION, WORKMANSHIP, PROTECTION, CUTTING AND PATCHING,
DAMAGE TO OTHER WORK, PRELIMINARY OPERATIONS, STORAGE, ADJUSTMENTS, CLEANING, ETC.
ALL WORK SHALL BE IN CONFORMANCE WITH ALL LOCALLY ENFORCED, FEDERAL, STATE AND
LOCAL CODES AND ORDINANCES INCLUDING ANY SPECIAL TENANT REQUIREMENTS IN ADDITION TO
THOSE SPECIFIED.
GENERAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND
INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REQUIRED
COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS.
SCOPE OF WORK
1.
ONLY MAJOR EQUIPMENT IS SHOWN ON THE DRAWINGS. THE PLUMBING CONTRACTOR SHALL BID
AND CONSTRUCT A COMPLETE AND OPERATIONAL SYSTEM. MISCELLANEOUS EQUIPMENT
REQUIRED TO COMPLETE THE WORK IS IN THE PLUMBING CONTRACTOR'S SCOPE - ASSUME NO
WORK OR EQUIPMENT IS PROVIDED BY OTHERS UNLESS STATED AS SUCH.
2. DURING BIDDING:
2.1.VERIFY THE EXISTING CONDITIONS AND COMPENSATE FOR ANY VARIATIONS IN THE SCOPE AS A
RESULT.
2.2.
REVIEW THE DRAWINGS AND SPECIFICATIONS OF OTHER TRADES. WHERE THERE IS
UNCERTAINTY ABOUT WHICH TRADE PROVIDES THE WORK, CONSULT WITH THE GENERAL
CONTRACTOR FOR CLARIFICATION.
2.3.
WHERE THERE IS A CONFLICT THAT CANNOT BE RESOLVED BY THE GENERAL CONTRACTOR,
ADVISE ENGINEER PROMPTLY FOR A RESOLUTION. DO NOT PROVIDE WORK WHEN THERE IS
UNCERTAINTY ON WHAT WORK IS TO BE PERFORMED.
3. THE DRAWINGS ARE GENERATED BY COMPETENT PROFESSIONALS, HOWEVER, THERE MAY STILL BE
ERRORS OR AREAS OF CONFUSION. AS PART OF THE BIDDING PROCESS, REPORT TO THE TENANT
ANY ERRORS OR UNCLEAR DIRECTIONS THAT YOU HAVE IDENTIFIED.
4. REVIEW LANDLORD CONSTRUCTION CRITERIA
5. ALL WORK INCLUDING, BUT NOT LIMITED TO PARTS, MATERIAL, EQUIPMENT AND LABOR SHALL BE
GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE BY THE ENGINEER AND TENANT. WHERE AN
EQUIPMENT MANUFACTURER HAS A WARRANTY THAT EXCEEDS ONE YEAR, THAT WARRANTY PERIOD
SHALL APPLY TO THIS PROJECT.
C. DOCUMENTS
1.
THE DRAWINGS ARE CONSTRUCTION DOCUMENTS, NOT SHOP DRAWINGS. THEY ARE NOT CREATED
TO SHOW ALL DETAILS REQUIRED FOR A COMPLETE INSTALLATION BUT INSTEAD TRUST THAT THE
INSTALLING CONTRACTOR IS EXPERIENCED AND LICENSED AS A MASTER PLUMBER (OR SIMILAR
DEFINITION DEPENDING ON THE JURISDICTION).
2. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF EQUIPMENT AND MATERIALS EXACTLY
AS SPECIFIED HEREIN. WHERE MORE THAN ONE MANUFACTURER IS MENTIONED ANY ONE MAY BE
UTILIZED. SUBSTITUTE MANUFACTURERS MAY BE OFFERED ONLY AS AN ALTERNATE TO THE
SPECIFIED EQUIPMENT AND MATERIAL.
2.1.SUBSTITUTIONS
2.1.1. THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE CONTRACT DOCUMENTS ARE
FOR THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A BASE LEVEL OF QUALITY. THE
GENERAL CONTRACTOR'S BID WILL CONTEMPLATE THE USE OF THE EQUIPMENT AND
MATERIALS EXACTLY AS INDICATED.
2.1.2. THE GENERAL CONTRACTOR SHALL SUBMIT FOR APPROVAL, WITH HIS BID QUOTATION, A LIST
OF ANY PROPOSED SUBSTITUTIONS OF MATERIALS AND EQUIPMENT FOR THOSE ON
WHICH THE ORIGINAL DESIGN WAS BASED. A FULL DESCRIPTION OF ALL PROPOSED
SUBSTITUTED ITEMS, THE CHANGE TO THEIR BID PRICE OR OTHER REASONS FOR SUCH
SUBSTITUTIONS SHALL ACCOMPANY THE BID. ALL ACCESSORIES, FEATURES, ETC., SUPPLIED
WITH THE SUBSTITUTED MANUFACTURER'S PRODUCT SHALL ALSO BE INCLUDED IN THE BID.
2.1.3. IF THE GENERAL CONTRACTOR DOES NOT SUBMIT PROPOSED SUBSTITUTIONS WITH THEIR BID
THE TENANT SHALL CONSIDER THE BIDDER TO BE PROPOSING THE MANUFACTURERS AND
MODEL NUMBERS SPECIFIED HEREIN AND SHOWN ON THE CONTRACT DRAWINGS.
2.1.4. SUBSTITUTIONS AFTER CONTRACT AWARD SHALL NOT BE PERMITTED.
3. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED
MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE
SPECIFICATIONS. REFER TO EACH SECTION FOR ANY SPECIFIC REQUIREMENTS.
D. CONSTRUCTION COORDINATION
1.
2.
3.
4.
5.
6.
7.
DURING BIDDING YOU VISITED THE SITE. WORK WITH THE GENERAL CONTRACTOR TO COORDINATE
ANY CONFLICTS WITH EXISTING CONDITIONS. THIS WORK SHALL BE PROVIDED AT NO ADDITIONAL
COST TO THE TENANT.
IN THE EVENT THE WORK OF TWO OR MORE TRADES INTERFERE WITH EACH OTHER AND THIS WAS
NOT IDENTIFIED DURING BIDDING, AND A DEVIATION FROM DESIGN IS NECESSARY, NEITHER WORK
SHALL PROCEED UNTIL THE TENANT HAS BEEN NOTIFIED OF THE CONFLICT AND THEY HAVE
RENDERED A DECISION AS TO WHAT CHANGES SHOULD BE MADE AND NO ADDITIONAL COSTS WILL
BE ACCEPTED.
GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE
REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE
PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF
DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE GENERAL CONTRACTOR CAUSING THE
DAMAGE.
IT IS ESSENTIAL THAT ALL WORK AT THE PROJECT BE DONE AS SUCH TIME AND IN SUCH MANNER AS
NOT TO INTERFERE WITH THE NORMAL OPERATIONS OF THE FACILITY. A WORK SCHEDULE SHALL BE
ARRANGED WITH THE TENANT TO FACILITATE WORK WITH A MINIMUM OF INTERFERENCE WITH THE
TENANT'S OPERATIONS.
AREAS TO BE USED FOR STORAGE SHALL BE ONLY AS DIRECTED BY THE TENANT. ALL STORED
MATERIAL SHALL BE RELOCATED OR REMOVED FROM THE SITE AS DIRECTED BY THE TENANT.
DAILY, AND AT THE COMPLETION OF THE WORK, EACH GENERAL CONTRACTOR SHALL REMOVE ALL
EXCESS MATERIALS AND DEBRIS CAUSED BY HIS WORK. UPON COMPLETION OF EACH GENERAL
CONTRACTOR'S WORK, CONDITIONS OF THE SPACE(S) SHALL BE THE SAME AS FOUND PRIOR TO
COMMENCEMENT OF THE WORK. FAILURE TO DO SO MAY RESULT IN THE TENANT'S EMPLOYMENT
OF A SEPARATE SERVICE TO OBTAIN THIS CONDITION AND REDUCING THE FACTOR'S CONTRACT
AMOUNT BY THE COST OF SUCH A SERVICE.
EACH GENERAL CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO OTHER WORK
CAUSED BY HIS WORK OR THROUGH THE NEGLECT OF HIS, OR HIS SUB-TRADE'S PERSONNEL. ALL
PATCHING, REPAIRING, REPLACEMENT AND PAINTING, ETC. SHALL BE DONE AS DIRECTED BY THE
TENANT BY THE CRAFTSMEN OF THE TRADES INVOLVED. THE COSTS OF SUCH WORK SHALL BE PAID
BY THE CONTRACTOR CAUSING THE DAMAGE.
JUST SINKS (847) 678-5150
SINK: LLVR2117, STRAINER:
1135, FAUCET: DELTA 101DST
GC TO MAKE FINAL CONNECTIONS. INSTALL MIXING VALVE BELOW
FIXTURE, CONNECT TO SUPPLY PIPING AT FIXTURE, SET WATER TEMP. @
110° F.
EQUIPMENT, PIPING, DUCTWORK, ETC. SHALL NOT BE SUPPORTED FROM ANY CEILINGS, OTHER
PIPING, CONDUIT OR DUCTWORK, ROOF DECK, OR JOIST BRIDGING. ITEMS SHALL BE SUPPORTED
FROM ACCEPTABLE STRUCTURAL BUILDING COMPONENTS AS DETERMINED BY THE ARCHITECT AND
STRUCTURAL ENGINEER.
+1 (513) 765-6000
p
+1 (516) 393-2484
Macy's Store Number: (687)
*SELECT 1-HOLE DRILLING CONFIGURATION. G.C. TO MAKE FINAL
CONNECTIONS. INSTALL MIXING VALVE BELOW FIXTURE, CONNECT TO
SUPPLY PIPING AT FIXTURE, SET WATER TEMP. @ 110° F IF REQUIRED.
Revisions:
Mark
PART 2 - MATERIALS
By
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
Architect of Record
A. GENERAL
PROVIDE STOP VALVES AT EVERY FIXTURE ON BOTH HOT AND COLD WATER SUPPLY LINES. VALVES,
ESCUTCHEONS, FITTINGS, ETC. MUST BE CHROME PLATED. WHERE EXPOSED, CHROME PLATED PIPE
IS TO BE USED.
2. ANYTHING NOT NOTED AS EXISTING IS TO BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT.
3. INSULATION SHALL BE BY OWENS-CORNING, KNAUF, OR MANVILLE.
3.1.ALL ABOVE GROUND PIPING SHALL BE INSULATED WITH FIBERGLASS PIPING INSULATION WITH AN
ALL SERVICE JACKET AND SELF SEALING LAP (ASJ/SSL).
3.1.1. DOMESTIC HOT AND COLD WATER PIPING UP TO 3/4 INCH DIAMETER - 1/2 INCH THICK.
3.2.
FITTINGS AND VALVES SHALL BE INSULATED WITH PRE-MOLDED FIBERGLASS FITTINGS AND
COVERED WITH A PRE-FORMED PVC FITTING COVER.
4. ALL FIXTURES AND EQUIPMENT NOT SPECIFIED HERE-IN ARE BEING PROVIDED BY OTHERS. THIS
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ROUGHING IN ALL SERVICES FOR ALL
EQUIPMENT WHETHER PROVIDED BY THIS GENERAL CONTRACTOR OR OTHERS. GENERAL
CONTRACTOR SHALL COORDINATE HIS INSTALLATION WITH THE APPROPRIATE EQUIPMENT SUPPLIER
FOR PROPER ROUGH IN INFORMATION AND SHALL REVISE THE DESIGN AS REQUIRED TO MATCH THE
EQUIPMENT BEING SUPPLIED. THIS GENERAL CONTRACTOR SHALL PROVIDE ALL LABOR AND
MATERIALS REQUIRED TO CONNECT ALL FIXTURES TO THE PLUMBING SYSTEMS INCLUDING BUT NOT
LIMITED TO; ALL WATER CONNECTIONS FROM APPROPRIATE STOP OR VALVE, ALL DIRECT SANITARY
CONNECTIONS, ALL WASTE CONNECTIONS TO SINKS, ETC.
5. FIRE STOPPING - REFER TO ARCHITECTURAL DRAWINGS FOR WALL TYPE AND UL CONSTRUCTION
DESIGN NUMBER. FOR RATED MASONRY WALL AND FLOOR ASSEMBLIES, PROVIDE A UL APPROVED
THROUGH-PENETRATION FIRE STOP SYSTEM NUMBER C-AJ-1175. FOR RATED GYPSUM BOARD
ASSEMBLIES, PROVIDE A UL APPROVED THROUGH-PENETRATION FIRE STOP SYSTEM NUMBER
W-L-1003.
6. ABOVE GROUND WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON NO-HUB PIPE
WITH STAINLESS STEEL BANDED JOINTS AND BE HUNG PER C.I.S.P.I. REQUIREMENTS OR SCHEDULE 40
DWV PVC PIPING AND FITTINGS WITH SOLVENT WELDED JOINTS.
7. ABOVE GROUND WATER PIPING, 3" AND SMALLER, SHALL BE TYPE "L" HARD DRAWN COPPER PIPE
WITH WROUGHT COPPER FITTINGS AND 95-5 SOLDERED JOINTS. AS AN ALTERNATE THE GENERAL
CONTRACTOR MAY UTILIZE COPPER PRESS FITTINGS (PROPRESS SYSTEM) AS MANUFACTURED BY
VIEGA. FITTINGS SHALL CONFORM TO THE MATERIAL AND SIZING REQUIREMENTS OF ASME B16.18 OR
ASME B16.22. O-RINGS FOR FITTINGS SHALL BE EDPM. INSTALLATION OF FITTINGS SHALL CONFORM
TO CODE AND THE MANUFACTURER'S SPECIFICATIONS/REQUIREMENTS. WATER PIPING JOINTS
BETWEEN DIFFERENT MATERIALS SHALL BE PER THE LOCALLY ENFORCED PLUMBING CODE SECTION
605.22.
Date
07/07/16
1
1.
XX
KEY NOTES - PLUMBING AND FIRE PROTECTION DEMOLITION PLAN
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
1.
EXISTING HOT WATER PIPE TO REMAIN.
2.
EXISTING COLD WATER PIPE TO REMAIN.
2016-026A
3.
SPRINKLER HEAD TO BE REMOVED.
Seal
EXTG
VESTIBULE
N.I.C.
3
3
3
TG
IRS
2
I.C.
EXTG
MECH
NAME:
N.I.C.
DATE:
EXTG
ELEV LOBBY
PART 3 - EXECUTION
REG NO:
N.I.C.
A. GENERAL
1.
THE ENTIRE PLUMBING INSTALLATION, MATERIALS, EQUIPMENT, ETC. SHALL CONFORM TO THE
REQUIREMENTS OF THE LOCALLY ENFORCED CODES AND STANDARDS.
1.1.COORDINATE YOUR WORK WITH THE GENERAL CONTRACTOR TO VERIFY ALL PLUMBING ROUGH IN
DIMENSIONS MEET THE THESE REQUIREMENTS.
1.2.VERIFY FINAL ROUGH IN WITH ARCHITECT PRIOR TO WALL INSTALLATION.
2. TEST ALL SEWER AND WATER PIPING IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES.
3. ALL OVERHEAD PIPING IS TO BE ROUTED TIGHT TO BUILDING STRUCTURE.
4. PIPING IS NOT PERMITTED IN DEMISING WALLS.
5. DO NOT ROUTE ANY WATER CONVEYING PIPING OVER ELECTRICAL EQUIPMENT.
6. ALL EXPOSED OR ACCESSIBLE P-TRAPS MUST BE PROVIDED WITH BOTTOM CLEANOUT PLUGS.
7. INSULATE EXPOSED P-TRAPS, HOT AND COLD VALVES AND PIPING SERVING HANDICAPPED
LAVATORIES.
8. PRIOR TO ANY ISOLATION OF SYSTEMS, SHUTDOWNS OR DEMOLITION THE G.C. SHALL PROVIDE
NECESSARY INVESTIGATION AND NOTIFY THE FACILITIES ENGINEERING/MAINTENANCE PERSONNEL
OF WORK TO BE PERFORMED SO AS TO AVOID ANY DETRIMENTAL SHUTDOWN OF SYSTEMS TO
ADJACENT SPACES.
9. IF SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM. CONSTRUCTION MATERIALS
ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50
SMOKE DEVELOPMENT FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED TYPE PER NFPA 70.
10. NO PLUMBING OR FIRE PROTECTION PIPING OR EQUIPMENT MAY BE SUPPORTED FROM THE
SUSPENDED CEILING SYSTEM, BUT MUST BE INDEPENDENTLY SUPPORTED FROM THE BUILDING
STRUCTURE.
11. ALL FLOOR DRAINS/CLEANOUTS ARE TO BE INSTALLED FLUSH WITH THE FINISHED FLOOR.
12. IF TRENCHING OCCURS, G.C. TO X-RAY EXISTING FLOOR TO DETERMINE LOCATIONS OF THE EXISTING
UNDER FLOOR BUILDING COMPONENTS, PRIOR ANY CORE DRILLING OR PLUMBING ROUGH-IN WORK
IS STARTED.
13. FURNISH ACCESS DOORS FOR WALL CLEAN OUTS AND VALVES IN WALLS.
Engineer
3
C
3
3
1
3
3
3
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Job# 2016128.00
3
3
3
3
3
Seal
3
B. PIPING
1.
2.
3.
PIPING SHALL BE SUPPORTED PER CODE AND LANDLORD STANDARDS.
PVC PIPING SHALL NOT BE INSTALLED IN A RETURN AIR PLENUM.
ALL SANITARY AND VENT PIPING SHALL PITCH TO IT'S APPROPRIATE MAIN AT NO LESS THAN 1/8" PER
FOOT SLOPE.
EXTG
SALES AREA
N.I.C.
NAME:
Michael B. Walsh
DATE:
07/07/2016
REG NO:
123816
D. DOMESTIC WATER
1.
2.
PROVIDE ANY LANDLORD REQUIRED METERS AND READERS.
TEST WATER PIPING TO HYDROSTATIC PRESSURE OF 100 PSIG. FOR TWO HOURS. STERILIZE ALL
DOMESTIC WATER PIPING IN ACCORDANCE WITH A.W.W.A. STANDARDS.
E. INSULATION
1. INSTALLATION SHALL CONFORM TO THE MANUFACTURER'S RECOMMENDATIONS, AND IN
ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES.
2. CLEAN AND DRY SURFACES PRIOR TO INSULATING.
3. EXTEND INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, HANGERS AND SIMILAR
PENETRATIONS.
4. INSULATION JACKET AND FITTING COVER MUST BE PLENUM RATED.
5. IT IS ESSENTIAL THAT THE INTEGRITY OF THE VAPOR-BARRIER BE MAINTAINED. SEAL ALL
PENETRATIONS OF THE VAPOR BARRIER BY STAPLES, HANGERS OR WHERE OTHERWISE DAMAGED.
6. MAINTAIN ACCESS TO VALVES.
Nextore project
Number
73052
ISSUED FOR:
F. FIRE PROTECTION
1. ALL WORK IS TO BE COMPLETED BY THE LANDLORD'S SPRINKLER CONTRACTOR AT THE GC'S
EXPENSE. SPRINKLER CONTRACTOR TO INCLUDE ALL WORK, INCLUDING BUT NOT LIMITED TO,
LANDLORD COORDINATION, SUBMITTALS AND CALCULATIONS, DRAIN DOWNS, ECT., AS REQUIRED
TO COMPLETE THE SPRINKLER SYSTEM REVISIONS TO SUPPORT THE NEW LENS CRAFTERS.
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
PLUMBING
SPECIFICATION,
SCHEDULE AND
DEMOLITION PLANS
Title
E. METHODS
1.
p
6 Creamery Brook, East Granby, CT 06026
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
REMARKS
ROUND SINK FOR CONTACT LENS
1.
B.
MODEL # /
COLOR
SK-3
PART 1 - GENERAL
A.
MFG./PHONE #
4000 Luxottica Place, Mason, OH 45040
FR I A R
MARK
SUPPLIED/
INSTALLED
BY
a
a
PLAN NORTH
1
PLUMBING AND FIRE PROTECTION DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
Date
07-01-16
Sheet
Drawn By
GRD
Checked By
MTB
P100
6
1
7
SINK (SK3 & SK7)
2
8
107
N.I.C.
5
4
SINK
SEP-1
4
GS-CL02-R
105
SAN.
SK3
106
NEW
STOCK
WATER
ELBOW DOWN
WALL CLEANOUT
TEE OUTLET UP
M
TEE OUTLET DOWN
4.2
2"
CAP ON END LINE
SK5
SANITARY PIPING (W)
3/4"
COLD WATER (CW)
O/H
OVERHEAD
VENT
DN
DOWN
2"
1/2"
1/2"
1-1/2"
U/G
UNDERGROUND
-
3/4"
3/4"
-
EX
WCO
EXISTING
WALL CLEANOUT
WH
PLUMBING FIXTURES
p
+1 (513) 765-6000
6 Creamery Brook, East Granby, CT 06026
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Macy's Store Number: (687)
VALVE
HOT WATER (HW)
COLD
4000 Luxottica Place, Mason, OH 45040
POINT OF NEW CONNECTION
TO EXISTING PIPING OR SYSTEM
SANITARY VENT PIPING (V)
HOT
a
a
WATER METER
NOTE: (SK1 THRU 7) CONTRACTOR WILL BE REQUIRED TO FURNISH ALL LABOR, PIPING MATERIALS
AND APPURTENANCES NECESSARY TO COMPLETE INSTALLATION OF SINKS, FAUCETS AND DRAINS
FURNISHED BY OWNER.
WAITING
SK3
4.0
(ALL SYMBOLS SHOWN ARE NOT
NECESSARILY USED ON THE DRAWINGS)
ELBOW UP
DRAIN
SK3 SK7
ELECTRIC WATER HEATER
CONTACT
LENS
2.0
4.0
FIXTURE
3 10
4.0
PLUMBING FIXTURE
CONNECTION SCHEDULE
EXTG
ELEV LOBBY
CASHWRAP
9
2.0
2
SERVICE CONNECTION SIZE
N.I.C.
SK7
SAN F.U. SAN F.U. C.W F.U. WTR. DMD.
TOTAL
EACH
TOTAL
EACH
TOTALS
EXTG
MECH
TG
IRS
I.C.
QTY.
PLUMBING FIXTURE
PLUMBING SYMBOLS
WC
PLUMBING CALCULATIONS
Revisions:
Mark
STANDARD P.D.I. WH 201 WATER HAMMER ARRESTER
SCHEDULE
N.I.C.
Date
By
07/07/16
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
1
P.D.I. UNITS
FIXTURE UNITS
1-3
4-11
12-32
33-60
61-113 114-154 155-330
R
EXTG
SALES AREA
OPTICAL
STATION
N.I.C.
104
XX
XX
KEY NOTES - SANITARY/VENT PLAN
1.
CONNECT NEW 1" PUMP DISCHARGE PIPE TO EXISTING SANITARY LINE DOWN AT THIS POINT.
2.
CONNECT NEW 1 1/2" VENT TO EXISTING 2" VENT UP AT THIS POINT.
3.
CONTRACTOR SHALL RUN ALL PLUMBING PIPING IN CABINET OR IN WALLS.
4.
THE CEILING IN THIS AREA IS A PLENUM. USE CODE MINIMUM PIPING TO CONNECT TO THE BUILDING SERVICES.
5.
PLUMBING CONTRACTOR TO PROVIDE WALL MOUNTED, 18"X18" ACCESS PANEL FOR ACCESS TO THE SEWAGE
EJECTOR PUMP. ACCESS PANEL TO BE SUITABLE FOR WALL TYPE IN WHICH IT WILL BE INSTALLED, HINGED, WITH
A QUARTER TURN, SCREWDRIVER CAM LATCH. COORDINATE WITH GENERAL CONTRACTOR. GENERAL
CONTRACTOR TO PAINT ACCESS PANEL.
6.
EXISTING 3" SANITARY DOWN TO REMAIN.
7.
EXISTING 2" VENT UP TO REMAIN.
8.
1" PUMP DISCHARGE.
9.
1 1/2" VENT LINE.
KEY NOTES - SUPPLY PLAN
1.
CONNECT TO EXISTING DOMESTIC WATER PIPE. G.C. TO COORDINATE WORK WITH LANDLORD FOR WATER TIE
IN. SEE MPE-100
2.
REFER TO DETAIL C/P201 FOR WATER HEATER PIPING DETAIL.
3.
CONTRACTOR SHALL RUN ALL PLUMBING PIPING IN CABINET OR IN WALLS.
2016-026A
4.
APPROXIMATE LOCATION OF NEW SPRINKLER HEAD. FINAL LOCATION TO BE DETERMINED BY THE LANDLORD
REQUIRED SPRINKLER CONTRACTOR. SPRINKLER CONTRACTOR'S WORK TO BE AT GC'S EXPENSE.
Seal
5.
NO WORK IN THIS AREA.
6.
EXISTING COLD WATER PIPE TO REMAIN.
7.
NEW 1/2 " COLD WATER LINE DN TO SINK.
SANITARY AND VENT
8.
EXISTING HOT WATER PIPE TO REMAIN.
9.
NEW 3/ 4" COLD WATER PIPE.
SCALE: 1/4" = 1'-0"
10. PROVIDE NEW SPRINKLER HEAD IN SOFFIT. LOCATION TO BE COORDINATED WITH SOFFIT LIGHTING AND
CASEWORK BELOW. LANDLORD'S SPRINKLER CONTRACTOR SHALL DETERMINE FINAL HEAD LOCATION TO MEET
ALL CODE REQUIREMENTS.
PLAN NORTH
1
FR I A R
Architect of Record
EXTG
VESTIBULE
SINK AND FAUCET (SEE
SCHEDULE)
10. 1 1/2" SANITARY LINE.
TG
IRS
COLD WATER SUPPLY TO SINK
C
IWH-1B
2
SHUT OFF VALVE
107
EXTG
ELEV LOBBY
4
N.I.C.
5
3
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Job# 2016128.00
4
CONTACT
LENS
1" PIPING TO ABOVE CEILING FOR
DISCHARGE WASTE
SEP-1
CASHWRAP
N.I.C.
7
SCALE: NONE
PROVIDE UNIONS OR
SIMILAR CONNECT
TO ALLOW PUMP TO
BE REMOVED FOR
SERVICING. INSTALL
UNIONS ABOVE TOP
OF PUMP AND IN A
LOCATION THAT IS
EASY TO ACCESS.
4
REG NO:
DRAIN FROM SINK
WATER HEATER PIPING SCHEMATIC
1 1/2" VENT PIPING
TO ABOVE CEILING
SK7
6
1
9
I.C.
DATE:
Engineer
EXTG
MECH
4
WATER SUPPLY
HOT WATER SUPPLY TO
SINK
TANKLESS WATER
HEATER (SEE SCHEDULE)
SK3
281 Farmington Avenue
Farmington, CT. 06032
NAME:
N.I.C.
SK7
ASSOCIATES INC.
4
GS-CL02-R
105
2
NEW
STOCK
PROVIDE BALL VALVE TO STOP BACK FLOW
WHEN PUMP IS REMOVED FOR SERVICE.
INSTALL VALVE ADJACENT TO UNION
IWH-1A
SK3
4
WAITING
SK3
106
3
8
4
4
N.I.C.
10
5
CHECK VALVE
Seal
10
2" PIPING TO SINKS FOR DRAIN
4
4
EJECTOR PUMP WITH RESERVOIR
10
4
RETAIL
101
D
SANITARY & VENT ISOMETRIC
A
SEWAGE EJECTOR PUMP PIPING SCHEMATIC
5
SCALE: NONE
HANGER ROD
SCALE: NONE
EXISTING WATER LINE
3
1
3/4"
NEW ISOLATION
VALVE
DATE:
07/07/2016
REG NO:
123816
73052
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
PIPE
3/4"
1/2"
Title
FIBERGLASS INSULATION
180° RIBBED 18 GUAGE SHIELD
SIMILAR TO ANVIL #168
RIB (TYPICAL)
PLUMBING PLANS
AND DETAILS
1 2"
1/2"
3
SK3
B
104
ASJ/SSL BUTT
STRIP (TYPICAL)
HEAVY DUTY CLEVIS HANGER,
MATERIAL TO MATCH PIPE
SK7
2
N.I.C.
LOCKING NUT
IWH-1B
IWH-1A
OPTICAL
STATION
Michael B. Walsh
Nextore project
Number
SUPPORT NUT
2
EXTG
SALES AREA
NAME:
SUPPLY ISOMETRIC
SCALE: NONE
E
Date
PIPE SUPPORT DETAIL - INSULATED PIPING
SCALE: NONE
PLAN NORTH
2
WATER SUPPLY AND FIRE PROTECTION
SCALE: 1/4" = 1'-0"
07-01-16
Sheet
Drawn By
GRD
Checked By
MTB
P200
ELECTRICAL SYMBOLS
GENERAL PROVISIONS
A. GENERAL CONDITIONS, CODES & STANDARDS
1.
2.
3.
4.
A.
GENERAL CONDITIONS OF THE CONTRACT FOUND IN THE ARCHITECTURAL DRAWINGS, GENERAL
AND SPECIAL CONDITIONS OF THE AMERICAN INSTITUTE OF ARCHITECTS (AIA) (NSPE)(NEC) AND ANY
OF THE TENANT'S GENERAL REQUIREMENTS SHALL APPLY UNLESS NOTED OTHERWISE.
REFER TO THE GENERAL CONDITIONS ON THE ARCHITECTURAL DOCUMENTS AND THE GENERAL
AND SPECIAL CONDITIONS OF THE AIA FOR ADDITIONAL REQUIREMENTS REGARDING; SAFETY,
COORDINATION & COOPERATION, WORKMANSHIP, PROTECTION, CUTTING AND PATCHING,
DAMAGE TO OTHER WORK, PRELIMINARY OPERATIONS, STORAGE, ADJUSTMENTS, CLEANING, ETC.
ALL WORK SHALL BE IN CONFORMANCE WITH ALL LOCALLY ENFORCED, FEDERAL, STATE AND LOCAL
CODES AND ORDINANCES INCLUDING ANY SPECIAL THE TENANT REQUIREMENTS IN ADDITION TO
THOSE SPECIFIED.
GENERAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND
INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REQUIRED
COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS.
B. SCOPE OF WORK
THIS CONTRACT SHALL INCLUDE THE FURNISHING, INSTALLING, CONNECTING, AND OPERATION OF
ALL EQUIPMENT WHICH IS A PART OF THE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS AND
AS REQUIRED BY SIMILAR INSTALLATIONS. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON
THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO
COMPLETE THE WORK AND WHICH IS USUALLY INCLUDED IN WORK OF A SIMILAR CHARACTER SHALL
BE FURNISHED AND INSTALLED UNDER THIS CONTRACT AT NO ADDITIONAL COST TO THE TENANT.
GENERAL CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO PROVIDE THE
TENANT A COMPLETE, CODE APPROVED AND OPERATIONAL ELECTRICAL SYSTEMS.
2. CAREFULLY READ SPECIFICATION FOR ALL PARTS OF THE WORK SO AS TO BECOME FAMILIAR WITH
ALL TRADES' WORK SCOPE. CONSULT WITH OTHER TRADES TO INSURE PROPER LOCATIONS AND
AVOID INTERFERENCES. ANY CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE TENANT
BEFORE WORK IS COMMENCED.
3. ALL CONTRACTORS SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO
COMPARE THEM WITH THE DRAWINGS AND SPECIFICATIONS, NOTE THE EXISTING CONDITIONS AND
OTHER WORK THAT WILL BE REQUIRED, AND THE NATURE OF THE CONDITIONS UNDER WHICH THE
WORK IS TO BE PERFORMED. NO ALLOWANCE SHALL BE MADE TO ANY CONTRACTOR BY REASON
OF THIS FAILURE TO HAVE MADE SUCH EXAMINATION OR OF ANY ERROR ON HIS PART.
4. ALL EXISTING UTILITY AND MECHANICAL SERVICES SHALL BE FIELD VERIFIED. CORRECTIONS TO THE
DESIGN AND INSTALLATION SHALL BE MADE WITHOUT ADDITIONAL COST TO THE TENANT.
5. THIS GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE THE OPENINGS WITH THE GENERAL
TRADES CONTRACTOR. THE FINAL LOCATIONS AND SIZES OF ALL DUCT AND LOUVER OPENINGS
SHALL BE PROVIDED BY THIS CONTRACTOR.
6. THIS CONTRACT SHALL ALSO INCLUDE ALL LABOR, MATERIALS AND MISCELLANEOUS EXPENSES
REQUIRED FOR ALL REQUIRED ELECTRICAL DEMOLITION OF THE EXISTING AREAS BEING RENOVATED.
6.1.
THE DEMOLITION SHALL CONSIST OF THE COMPLETE REMOVAL (PROPERLY DISPOSED OFF SITE
UNLESS OTHERWISE NOTED) OF ALL ELECTRICAL EQUIPMENT, CONDUIT, MATERIALS, ETC. NOT
REQUIRED IN THE FINAL DESIGN AND INSTALLATION OF THE ELECTRICAL SYSTEMS FOR THE
NEW RENOVATED AREAS.
6.2.
ALL UNDERGROUND SERVICES NOT BEING REUSED SHALL BE CAPPED BELOW THE FLOOR.
6.3.
ALL ABOVE GROUND SERVICES SHALL BE REMOVED BACK TO THEIR RESPECTIVE MAIN AND
CAPPED OR IF THE MAIN IS NOT REQUIRED, THE MAIN SHALL BE REMOVED IN IT'S ENTIRETY.
6.4.
COORDINATE ALL DEMOLITION WITH THE ARCHITECTURAL DOCUMENTS AND THE ARCHITECT
AND THE TENANT'S GENERAL REQUIREMENTS.
7. ALL WORK INCLUDING, BUT NOT LIMITED TO PARTS, MATERIAL, EQUIPMENT AND LABOR SHALL BE
GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE BY THE ENGINEER AND TENANT. WHERE AN
EQUIPMENT MANUFACTURER HAS A WARRANTY THAT EXCEEDS ONE YEAR, THAT WARRANTY PERIOD
SHALL APPLY TO THIS PROJECT.
1.
B.
C.
D.
2.
3.
4.
5.
6.
7.
8.
2.
EXCAVATIONS SHALL BE MADE IN OPEN TRENCHES. FLOORS SHALL BE SAW CUT. PIPING SHALL BE
LAID ON AN APPROPRIATELY GRADED 6" BED OF CLEAN AND DRY SAND. ENGINEERED FILL SHALL BE
USED TO BACKFILL TO 6" ABOVE THE PIPING. BACKFILL THE REMAINDER OF THE TRENCH UTILIZING
THE EXCAVATED MATERIAL IF APPROVED BY THE ARCHITECT OR THE TENANT. IF THE EXCAVATED
MATERIALS ARE NOT ACCEPTABLE, ENGINEERED FILL ACCEPTABLE TO THE ARCHITECT SHALL BE
UTILIZED TO BACKFILL THE REMAINDER OF THE TRENCH. BACKFILL SHALL BE ACCOMPLISHED IN 9"
LIFTS WITH ALL LIFTS COMPACTED TO 95% PROCTOR. PATCH FLOOR TO MATCH EXISTING.
EQUIPMENT, PIPING, DUCTWORK, ETC. SHALL NOT BE SUPPORTED FROM ANY CEILINGS, OTHER
PIPING, CONDUIT OR DUCTWORK, ROOF DECK, OR JOIST BRIDGING. ITEMS SHALL BE SUPPORTED
FROM ACCEPTABLE STRUCTURAL BUILDING COMPONENTS AS DETERMINED BY THE ARCHITECT AND
STRUCTURAL ENGINEER.
TESTS
1. TEST FOR GROUNDS, SHORT CIRCUITS, AND PROPER FUNCTION OF ALL EQUIPMENT AFTER
INSTALLATION IS COMPLETE. FAULTS IN THE INSTALLATION SHALL BE CORRECTED AT NO COST TO
THE TENANT.
GUARANTEES
1. GUARANTEE FOR ONE YEAR AFTER ACCEPTANCE BY TENANT, ALL WORKMANSHIP AND MATERIALS
FURNISHED.
PART 2 - PRODUCTS
A.
B.
C.
D.
E.
F.
E. METHODS
1.
GROUNDING
1. GROUND ALL CONDUITS, CABINETS, MOTORS, PANELS, AND OTHER EXPOSED NON-CURRENT
CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH THE NATIONAL
ELECTRICAL CODE ARTICLE 250.
2. GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY MEANS OF AN INSULATED GROUNDING
CONDUCTOR INSTALLED WITH ALL FEEDERS AND BRANCH CIRCUIT CONDUCTORS IN ALL CONDUITS.
F.
D. COORDINATION
GENERAL CONTRACTOR SHALL INCLUDE A VISIT TO THE JOB SITE AND TAKE INTO CONSIDERATION
MECHANICAL, ELECTRICAL AND GENERAL TRADE WORK CURRENTLY EXISTING AND WORK WHICH
MAY BE INSTALLED PRIOR TO CONTRACT AWARD. RELOCATION OF DUCTWORK, PIPING AND
EQUIPMENT, AS REQUIRED, TO AVOID THIS WORK SHALL BE PROVIDED AT NO ADDITIONAL COST TO
THE TENANT.
GENERAL CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE BUILDING SITE BEFORE STARTING
ANY FABRICATION OR DOING ANY WORK IN THE FIELD AND SHALL BE RESPONSIBLE FOR THE
CORRECT AND PROPER MEASUREMENTS OF HIS WORK ALONG WITH RESOLUTIONS FOR ANY
CONFLICT OF SPACE WITH OTHER TRADES.
WHERE THE WORK OF TWO OR MORE TRADES INTERFERE WITH EACH OTHER AND A DEVIATION
FROM DESIGN IS NECESSARY, NEITHER WORK SHALL PROCEED UNTIL THE TENANT HAS BEEN
NOTIFIED OF THE CONFLICT AND THEY HAVE RENDERED A DECISION AS TO WHAT CHANGES
SHOULD BE MADE.
GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE
REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE
PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF
DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE GENERAL CONTRACTOR CAUSING THE
DAMAGE.
IT IS ESSENTIAL THAT ALL WORK AT THE PROJECT BE DONE AS SUCH TIME AND IN SUCH MANNER AS
NOT TO INTERFERE WITH THE NORMAL OPERATIONS OF THE FACILITY. A WORK SCHEDULE SHALL BE
ARRANGED WITH THE TENANT TO FACILITATE WORK WITH A MINIMUM OF INTERFERENCE WITH THE
TENANT'S OPERATIONS.
AREAS TO BE USED FOR STORAGE SHALL BE ONLY AS DIRECTED BY THE TENANT. ALL STORED
MATERIAL SHALL BE RELOCATED OR REMOVED FROM THE SITE AS DIRECTED BY THE TENANT.
DAILY, AND AT THE COMPLETION OF THE WORK, EACH GENERAL CONTRACTOR SHALL REMOVE ALL
EXCESS MATERIALS AND DEBRIS CAUSED BY HIS WORK. UPON COMPLETION OF EACH GENERAL
CONTRACTOR'S WORK, CONDITIONS OF THE SPACE(S) SHALL BE THE SAME AS FOUND PRIOR TO
COMMENCEMENT OF THE WORK. FAILURE TO DO SO MAY RESULT IN THE TENANT'S EMPLOYMENT
OF A SEPARATE SERVICE TO OBTAIN THIS CONDITION AND REDUCING THE FACTOR'S CONTRACT
AMOUNT BY THE COST OF SUCH A SERVICE.
EACH GENERAL CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO OTHER WORK
CAUSED BY HIS WORK OR THROUGH THE NEGLECT OF HIS, OR HIS SUB-TRADE'S PERSONNEL. ALL
PATCHING, REPAIRING, REPLACEMENT AND PAINTING, ETC. SHALL BE DONE AS DIRECTED BY THE
TENANT BY THE CRAFTSMEN OF THE TRADES INVOLVED. THE COSTS OF SUCH WORK SHALL BE PAID
BY THE CONTRACTOR CAUSING THE DAMAGE.
PERMITS AND FEES
1. THE ELECTRICAL CONTRACTOR SHALL SECURE AND PAY FOR LOCAL AND/OR STATE PERMITS AND
INSPECTION FEES REQUIRED FOR THE ELECTRICAL WORK.
DEMOLITION
1. DEMOLITION OF EXISTING ELECTRICAL EQUIPMENT, IF APPLICABLE, SHALL BE PART OF THE
ELECTRICAL WORK AS INDICATED ON THE DRAWINGS.
1.
1.
DESCRIPTION OF WORK
1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL, EQUIPMENT AND TOOLS
NECESSARY TO COMPLETE THE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS OR SPECIFIED
HEREIN.
2. THE ELECTRICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH ALL PROVISIONS OF THE
NATIONAL ELECTRICAL CODE (NFPA 70), AS WELL AS ANY MODIFICATIONS OR REGULATIONS
PUBLISHED BY LOCAL OR STATE AUTHORITIES. THE ELECTRICAL WORK SHALL ALSO BE INSTALLED IN
ACCORDANCE WITH THE PROVISIONS OF THE LATEST EDITIONS OF THE STATE BUILDING CODE, NFPA
71, NFPA 101 AND THE AMERICANS WITH DISABILITIES ACT WHERE APPLICABLE.
3. ELECTRICAL, MECHANICAL, ARCHITECTURAL, STRUCTURAL, AND ALL OTHER DRAWINGS, AS WELL AS
SPECIFICATIONS AND ADDENDUMS SHALL BE PART OF THE CONTRACT DOCUMENTS.
4. EQUIPMENT AND MATERIALS USED ON THIS PROJECT SHALL BE NEW, U.L. LABELED AND MEET OSHA
REQUIREMENTS. EQUIPMENT AND MATERIAL SHALL BE PROTECTED AND SHALL BE THE
RESPONSIBILITY OF THIS GENERAL CONTRACTOR UNTIL FORMALLY ACCEPTED BY THE TENANT.
5. TEMPORARY ELECTRICAL SERVICE, LIGHTING, AND RELATED WIRING SHALL BE PROVIDED TO OSHA
REQUIREMENTS FOR THE USE OF ALL TRADES DURING CONSTRUCTION.
6. PROVIDE ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF ELECTRICAL WORK. ALL
CORE DRILLING OR CUTTING OF FIRE RATED FLOORS, SHAFTS AND WALLS SHALL BE FIRE STOPPED
PRIOR TO FINISH PATCHING. ALL PENETRATIONS SHALL BE FIRE SEALED TO MATCH THE FIRE RATING
OF THE FLOORS, SHAFTS OR WALLS PENETRATED.
7. TEMPERATURE AND INTERLOCK CONTROL COMPONENTS AND ALL RELATED CONDUIT AND WIRING
SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE INDICATED ON THE
DRAWINGS.
E.
C. DOCUMENTS
THE DRAWINGS ARE DIAGRAMMATIC, ALL WORK SHALL BE PERFORMED AS INDICATED ON THE
DRAWINGS UNLESS EXISTING CONDITIONS OR COORDINATION ISSUES REQUIRE CHANGES. THESE
CHANGES SHALL BE MADE WITH NO ADDITIONAL COST TO THE TENANT.
2. ANY INCIDENTAL ITEMS OR LABOR, ETC. NOT INCLUDED IN THE SPECIFICATIONS OR THE DRAWINGS
BUT REASONABLY IMPLIED AS NECESSARY FOR THE COMPLETE INSTALLATION OF ALL APPARATUS
SHALL BE INCLUDING IN BID.
3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY
MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED EVEN THOUGH NOT MENTIONED IN
BOTH.
4. IF ERRORS ARE FOUND IN THE DRAWINGS OR SPECIFICATIONS OR DISCREPANCIES OCCUR BETWEEN
THE SAME, OR BETWEEN THE FIGURES ON THE DRAWINGS, AND THE SCALE OF SAME OR BETWEEN
THE LARGER AND SMALLER DRAWINGS, OR IN THE DESCRIPTIVE MATTER ON THE DRAWINGS SHALL
BE REFERRED TO THE TENANT FOR REVIEW AND FINAL DECISION PRIOR TO THE BID DUE DATE.
5. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF EQUIPMENT AND MATERIALS EXACTLY
AS SPECIFIED HEREIN. WHERE
MORE THAN ONE MANUFACTURER IS MENTIONED ANY ONE MAY
BE UTILIZED. SUBSTITUTE MANUFACTURERS MAY BE OFFERED ONLY AS AN
ALTERNATE TO THE SPECIFIED EQUIPMENT AND MATERIAL.
5.1.
SUBSTITUTIONS
5.1.1.
THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE CONTRACT DOCUMENTS
ARE FOR THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A BASE LEVEL OF QUALITY.
THE GENERAL CONTRACTOR'S BID WILL CONTEMPLATE THE USE OF THE EQUIPMENT AND
MATERIALS EXACTLY AS INDICATED.
5.1.2.
THE GENERAL CONTRACTOR SHALL SUBMIT FOR APPROVAL, WITH HIS BID QUOTATION, A
LIST OF ANY PROPOSED SUBSTITUTIONS OF MATERIALS AND EQUIPMENT FOR THOSE ON
WHICH THE ORIGINAL DESIGN WAS BASED. A FULL DESCRIPTION OF ALL PROPOSED
SUBSTITUTED ITEMS, THE CHANGE TO THEIR BID PRICE OR OTHER REASONS FOR SUCH
SUBSTITUTIONS SHALL ACCOMPANY THE BID. ALL ACCESSORIES, FEATURES, ETC., SUPPLIED
WITH THE SUBSTITUTED MANUFACTURER'S PRODUCT SHALL ALSO BE INCLUDED IN THE BID.
5.1.3.
IF THE GENERAL CONTRACTOR DOES NOT SUBMIT PROPOSED SUBSTITUTIONS WITH THEIR
BID THE TENANT SHALL CONSIDER THE BIDDER TO BE PROPOSING THE MANUFACTURERS
AND MODEL NUMBERS SPECIFIED HEREIN AND SHOWN ON THE CONTRACT DRAWINGS.
5.1.4.
SUBSTITUTIONS AFTER CONTRACT AWARD SHALL NOT BE PERMITTED.
6. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED
MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE
SPECIFICATIONS. REFER TO EACH SECTION FOR ANY SPECIFIC REQUIREMENTS.
1.
PART I - GENERAL
G.
I.
THE EXISTING FIRE ALARM SYSTEM DOES NOT HAVE DETECTION OR NOTIFICATION APPLIANCES IN
THE SALES AND OFFICE AREAS. THIS IS A MINOR REMODEL, AND NO SYSTEM COMPONENTS ARE
ANTICIPATED.
XX-##
PART 3 - EXECUTION
A.
GENERAL MISCELLANEOUS
1. ALL CONDUIT RUN IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT SMALLER THAN 3/4" SHALL
NOT BE USED FOR ANY CIRCUIT HOMERUNS.
2. RACEWAYS EXPOSED TO DIFFERENT TEMPERATURES SHALL BE FILLED WITH AN APPROVED MATERIAL
IN ACCORDANCE WITH ARTICLE 300.7 OF THE NATIONAL ELECTRICAL CODE.
3. HANGERS, SUPPORTS, OR FASTENINGS SHALL BE PROVIDED AT EACH ELBOW, AT THE ENDS OF
STRAIGHT RUNS TERMINATING AT BOXES OR CABINETS, AND AT INTERMEDIATE POINTS AS REQUIRED
BY CODE. CONDUITS OR BOXES SHALL NOT BE SUPPORTED BY CEILING SUPPORT WIRES OR OTHER
CEILING SUPPORTING HARDWARE.
4. FIXTURE SUPPORTS SHALL BE IN ACCORDANCE WITH ARTICLE 410-15 OF THE NATIONAL ELECTRICAL
CODE, OR ANY LOCAL CODES WHICH MY APPLY.
5. PROVIDE PERMANENT NAMEPLATES WITH DESIGNATIONS FOR PANELBOARDS, FEEDER DEVICES,
DISTRIBUTION EQUIPMENT AND STARTERS.
6. PROVIDE TYPEWRITTEN DIRECTORY CARDS WITH BRANCH CIRCUIT IDENTIFICATION FOR BRANCH
CIRCUIT PANELBOARDS. PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS
SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH
HAZARDS IN ACCORDANCE WITH NEC 110.16.
7. INSTALL HANDLE GUARDS ON ALL BREAKERS FOR NIGHT LIGHTING, EMERGENCY AND SIMILAR
CIRCUITS.
8. ALL FLUSH MOUNTED PANELBOARDS SHALL HAVE (3) 3/4" EMPTY CONDUITS INSTALLED TO ABOVE
ACCESSIBLE CEILING FOR FUTURE USE.
9. THE FINAL LOCATIONS OF ALL EQUIPMENT, OUTLETS, ETC. SHALL BE SUBJECT TO REASONABLE
CHANGES IN LOCATION UP TO THE TIME OF ROUGHING-IN, AT NO ADDITIONAL COST TO THE
TENANT.
10. ELECTRICAL CONTRACTOR TO CONTACT TELEPHONE COMPANY AND MAKE NECESSARY
ARRANGEMENTS FOR TELEPHONE SERVICE.
11. AT ALL TIMES KEEP PREMISES AND BUILDING IN A NEAT AND ORDERLY CONDITION, FOLLOWING
TENANT'S INSTRUCTION IN REGARD TO STORING OF MATERIALS, PROTECTIVE MEASURES AND
DISPOSING OF DEBRIS.
XX
1.
2.
3.
4.
5.
6.
PANEL
WIRE AND CABLE
1. CONDUCTORS FOR POWER AND LIGHTING SHALL BE NEW 600-VOLT, 90 C, TYPE XHHW, THHN, OR
THWN INSULATION, MINIMUM SIZE #12-AWG, EXCEPT FOR CONTROL WIRING WHICH MAY BE
#14-AWG. OTHER SIZES SHALL BE AS NOTED ON THE DRAWINGS. CONDUCTORS SHALL BE COPPER,
UNLESS OTHERWISE APPROVED BY THE TENANT.
2. BRANCH CIRCUIT RUNS EXCEEDING 100 FEET IN TOTAL LENGTH FROM THE PANELBOARD TO THE
LAST DEVICE, SHALL BE #10-AWG CONDUCTORS UNLESS OTHERWISE NOTED.
3. ALL LOW VOLTAGE COMMUNICATIONS, FIRE ALARM, DATA, SECURITY, TELEPHONE AND ALL OTHER
MISCELLANEOUS LOW VOLTAGE WIRING INSTALLED IN CEILING SHALL BE PLENUM RATED.
4. TELEPHONE WIRING SHALL BE 4 PAIR 22/24 AWG (PLENUM RATED). MANUFACTURER SELECTED BY EC.
5. DATA (EYENET-POS) WIRING SHALL BE BERK-TEK LANMARK-1000, CATEGORY 6. RATED CMP, WHERE
USED IN PLENUM CEILINGS AND RATED OSP WHERE USED BELOW SLAB. PROVIDE 6' OF EXCESS
CABLE AT CASHWRAP AND 6' OF CABLE AT THE PHONEBOARD AND OTHER LOCATIONS. TENANT
VENDOR TO PERFORM PUNCHDOWN AND SYSTEMS VERIFICATION.
6. BASE PROJECT FOR LOW VOLTAGE WIRING (VOICE AND DATA) IS INSTALLATION OF RACEWAY ONLY
FOR THE ELECTRICAL CONTRACT.
PRICING FOR INSTALLATION AND TERMINATION OF
WIRING AT OUTLETS IN LENSCRAFTERS ONLY IS DESIRED. THE PUNCHDOWN AND CROSS CONNECTS
IN THE MACY'S CLOSETS ARE BY TENANT OR MACY'S IN BOTH BASE BID AND ALTERNATE BID CASES.
WIRING DEVICES
1. DUPLEX RECEPTACLES SHALL BE GROUNDING TYPE, NEMA 5-20R, RATED FOR 20 AMPS, 125 VOLTS,
WITH PROVISIONS FOR BACK AND SIDE WIRING.
1.1.
SPECIFICATION GRADE DUPLEX RECEPTACLE SHALL BE HUBBELL #5362 SERIES OR APPROVED
EQUAL, HEAVY DUTY, WHITE.
1.2.
ISOLATED GROUND DEDICATED DUPLEX RECEPTACLE SHALL BE HUBBELL #IG-5362 SERIES OR
APPROVED EQUAL, ORANGE.
1.3.
GROUND FAULT CIRCUIT INTERRUPTER (GFI) DUPLEX RECEPTACLES SHALL BE PROVIDED WHERE
INDICATED.
2. SWITCHES SHALL BE TOGGLE OPERATED, QUIET TYPE, RATED FOR 20 AMPS, 120/277 VOLTS, WITH
PROVISIONS FOR BACK AND SIDE WIRING. THREE WAY AND FOUR WAY SWITCHES SHALL BE
PROVIDED WHERE INDICATED.
2.1.
SINGLE POLE SWITCHES SHALL BE LEVITON #1221 SERIES OR APPROVED EQUAL, SILENT
ACTUATING, 20-AMP, 120/277V, WHITE.
2.2.
THREE POLE SWITCHES SHALL BE LEVITON #1223 SERIES OR APPROVED EQUAL, SILENT
ACTUATING, 20-AMP, 120/277V, WHITE.
3. DIMMERS SHALL BE LEVITON SLIDING DIMMER SWITCH, OF A RATING, VOLTAGE AND WATTAGE
SUITABLE FOR LOAD SERVED.COLORS OF DEVICES AND COVERPLATES SHALL WHITE.
4. WIRING DEVICES SHALL BE SPECIFICATION GRADE, AS MANUFACTURED BY HUBBELL, PASS &
SEYMOUR, ARROW HART, LEVITON AND GENERAL ELECTRIC, UON.
5. COVERPLATES FOR POWER, DATA & TELEPHONE SHALL BE LEVITON OR APPROVED EQUAL, WHITE,
PLASTIC.
6. LIGHTING CONTRACTORS SHALL BE IN NEMA 1 ENCLOSURE, NORMALLY OPEN ELECTRICALLY HELD,
120V, COIL, 20A. REFER TO PLANS FOR NUMBER OF POLES.
ILLUMINATED "EXIT" SIGN LIGHTING FIXTURE. CEILING MOUNTED OR
WALL MOUNTED. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON
FLOOR PLANS.
CIRCUIT
COMBINATION VOICE/DATA OUTLET - MOUNTED AT 18" AFF UNLESS
OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING
AND 3/4" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. "W" INDICATES
WALL MOUNTED AT 54" AFF, "C" INDICATES MOUNTED 8" ABOVE
COUNTER.
4000 Luxottica Place, Mason, OH 45040
p
+1 (513) 765-6000
a
6 Creamery Brook, East Granby, CT 06026
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Macy's Store Number: (687)
TELEPHONE OUTLET - MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED.
PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4" CONDUIT TO
ABOVE THE ACCESSIBLE CEILING. "W" INDICATES WALL MOUNTED AT
54" AFF, "C" INDICATES MOUNTED 8" ABOVE COUNTER, "P" INDICATES
PUBLIC TELEPHONE OUTLET - COORDINATE MOUNTING HEIGHT.
DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDING
TYPE, 20 AMPERE, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED.
DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED
IN FLOOR BOX.
"CLG" INDICATES MOUNTED IN CEILING
DATA OUTLET: MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED.
PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4" CONDUIT TO
ABOVE THE ACCESSIBLE CEILING. "W" INDICATES WALL MOUNTED AT
54" AFF, "C" INDICATES MOUNTED 8" ABOVE COUNTER. CLG INDICATES
CEILING MOUNTED.
COMBINATION DUPLEX RECEPTACLE AND VOICE/DATA OUTLET
MOUNTED IN FLOOR BOX.
DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE
MOUNTED IN FLOOR BOX.
2 2 PORT DATA OUTLET
Revisions:
Mark
BRANCH CIRCUIT WIRING
HOMERUN
MOTOR
Architect of Record
LIGHT FIXTURE: "AD" INDICATES FIXTURE TYPE "a" INDICATES SWITCH
CONTROL. REFER TO LUMINAIRE SCHEDULE FOR DESCRIPTION.
TL
CLIENT COMMENTS
6 PORT DATA OUTLET
6
CEILING MOUNTED OCCUPANT SENSOR
TRACK AND TRACK MOUNTED LIGHT FIXTURE (DESIGNATIONS VARY SEE PLANS)
#T-S
07/19/16
SWITCHED WIRING
"3" INDICATES THREE WAY SWITCH
"4" INDICATES FOUR WAY SWITCH
"C" INDICATES SWITCH MOUNTED 8" ABOVE COUNTER
"OS" INDICATES OCCUPANCY SENSOR SWITCH
"D" INDICATES DIMMER SWITCH - WATTAGE AS INDICATED ON PANEL
SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE
NEUTRAL CONDUCTOR
AD
By
Description
SUBMIT FOR PERMIT
4 PORT DATA OUTLET
4
3 3 PORT DATA OUTLET
SWITCH - SINGLE POLE TOGGLE TYPE - 120/277 VOLT, 1-HP RATED, 20
AMPERE, MOUNTED AT 48" AFF UNLESS OTHERWISE NOTED:
OS
Date
07/07/16
1
COMMUNICATIONS FLOOR BOX
SPEAKER TO REMAIN.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE. RETURN THE BALANCE TO MACY'S OPERATIONS. RECONNECT
CIRCUIT AS REQUIRED TO KEEP REMAINING LIGHT FIXTURES POWERED.
EXISTING STRIP LIGHTS BEHIND VALANCE ARE TO REMAIN.
EXISTING LIGHT FIXTURES ARE TO REMAIN.
EXISTING RECESSED, ADJUSTABLE ACCENT LIGHTS ARE TO REMAIN.
EXISTING 2X4 TO BE RELOCATED. SEE LIGHTING PLAN FOR NEW LOCATION. EXTEND CONDUIT AND CONDUCTOR AS
REQUIRED TO HAVE A COMPLETE AND OPERATIONAL SYSTEM.
a
LIGHTING TIME CLOCK
TC
DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20
AMPERE, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED:
"2" INDICATES CIRCUIT NUMBER
"E" EXISTING TO REMAIN
"WP" INDICATES WEATHERPROOF COVER
"D" DEDICATED CIRCUIT
"GFI" INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE
"R" INDICATES RECESSED
F
FIRE ALARM MANUAL PULL STATION MOUNTED AT 48" AFF.
F
FIRE ALARM AUDIO/VISUAL ALARM SIGNAL WALL MOUNTED AT 80" AFF.
V
FIRE ALARM VISUAL ONLY ALARM SIGNAL WALL MOUNTED AT 80" AFF.
SD
FIRE ALARM SMOKE DETECTOR
SD
FIRE ALARM SMOKE DETECTOR - DUCT MOUNTED
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
2016-026A
Seal
1
EXTG
VESTIBULE
N.I.C.
(D)
TG
IRS
DATE:
N.I.C.
2
I.C.
NAME:
EXTG
MECH
6
EXTG
ELEV LOBBY
(R)
REG NO:
N.I.C.
1
Engineer
C
2
2
(D)
(E)
(D)
1
(E)
4
4
(E)
(R)
(E)
2
(E)
3
3
3
(E)
3
(E)
3
(E)
3
(E)
3
(E)
(E)
3
EXTG
SALES AREA
5
(E)
5
(E)
5
5
4
(E)
4
(E)
(E)
(E)
S
4
4
(E)
(E)
(E)
(E)
NAME:
Michael B. Walsh
DATE:
07/07/2016
REG NO:
123816
4
Nextore project
Number
4
(E)
(E)
(E)
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
1
S
(E)
PLAN NORTH
1
73052
ISSUED FOR:
4
(E)
4
(E)
(E)
(E)
4
4
4
(E)
4
Seal
(E)
1
(E)
4
4
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
5
(E)
(E)
(E)
EX/D1
4
(E)
(E)
(E)
(E)
4
4
(E)
(E)
4
5
5
4
5
5
5
4
4
5
N.I.C.
5
(E)
5
(E)
(E)
5
5
3
5
(E)
(E)
(R)
(E)
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Job# 2016128.00
(E)
(E)
(E)
3
(E)
(E)
(E)
3
(D)
6
(E)
3
(R)
3
3
(R)
(E)
(E)
FIXTURES AND LAMPS
1. ALL FIXTURES AND LAMPS ARE FURNISHED BY TENANT, INSTALLED BY ELECTRICAL CONTRACTOR..
FIRE ALARM SYSTEM
D
JUNCTION BOX
J
KEY NOTES - ELECTRICAL DEMOLITION PLAN
LIGHTING AND RECEPTACLE PANELBOARDS
1. BRANCH CIRCUIT PANELBOARDS SHALL BE DEAD FRONT TYPE, WITH MAIN LUGS OR MAIN
OVERCURRENT DEVICE AS INDICATED, BRANCH OVERCURRENT DEVICES AS NOTED AND AN
EQUIPMENT GROUND BAR, ALL IN A FLUSH MOUNTED SHEET STEEL ENCLOSURE. MINIMUM SHORT
CIRCUIT CAPACITY SHALL BE 10,000 AMPS SYMMETRICAL FOR 120/208V, AND 14,000 AMPS
SYMMETRICAL FOR 277/480V APPLICATION UNLESS NOTED OTHERWISE.
2. ALL BREAKERS FEEDING HVAC EQUIPMENT SHALL BE HACR RATED, UNLESS OTHERWISE NOTED.
3. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE D, GENERAL ELECTRIC, ITE/SIEMENS AND
WESTINGHOUSE/CUTLER HAMMER.
SAFETY SWITCHES AND MOTOR STARTERS
1. SAFETY SWITCHES SHALL BE FUSIBLE OR NON-FUSIBLE AS INDICATED ON THE DRAWINGS. SWITCHES
SHALL BE QUICK-MAKE, QUICK-BREAK, HEAVY DUTY VISIBLE BLADE TYPE. ENCLOSURES SHALL BE
NEMA 1 TYPE UNLESS OTHERWISE INDICATED ON THE DRAWINGS. FUSED SHALL BE DUAL ELEMENT TIME DELAY TYPE.
2. MAGNETIC MOTOR STARTERS SHALL BE COMBINATION TYPE WITH THERMAL OVERLOAD, INTEGRAL
FUSED SAFETY SWITCH, H-O-A SELECTOR SWITCH, CONTROL TRANSFORMER, RUNNING PILOT LIGHT,
NEMA TYPE 1 ENCLOSURE, AND (2) NORMALLY OPEN AND (2) NORMALLY CLOSED AUXILIARY
CONTACTS.
3. ALL MOTORS OVER 1/8 HP SHALL BE PROVIDED WITH THERMAL OVERLOAD PROTECTION. OVERLOAD
PROTECTION SHALL BE PROVIDED INTEGRAL WITH THE MOTOR WINDINGS AND/OR MOTOR
CONTROLLER (PROVIDED BY OTHERS) UNLESS OTHERWISE INDICATED ON DRAWINGS.
RECESSED DOWNLIGHT. DESIGNATIONS VARY - SEE PLANS.
INFLOOR/UNDERFLOOR CONDUIT/WIRE
CONDUIT
1. CONDUIT SHALL BE HEAVY WALL RIGID GALVANIZED STEEL WHERE EXPOSED AND SUBJECT TO
DAMAGE, 8'-0" AFF AND BELOW, AND IN WET LOCATIONS WHERE INDICATED ON THE DRAWINGS.
UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC AND SHALL BE CONCRETE ENCASED (3'
MINIMUM) WHERE INDICATED ON THE DRAWINGS. A TRANSITION SHALL BE MADE TO HEAVY WALL
RIGID GALVANIZED STEEL BEFORE PVC CONDUITS PENETRATE THE FLOOR SLAB. INTERIOR CONDUITS
SHALL BE ELECTRICAL METALLIC TUBING (EMT). METAL CLAD (MC) CABLE MAY BE USED IF APPROVED
BY THE TENANT, AND INSTALLED IN LOCATIONS PERMITTED BY CODE.
2. FLEXIBLE METAL CONDUIT SHALL BE USED FROM OUTLET BOX TO INDIVIDUAL RECESSED LIGHT
FIXTURES, AND FOR FINAL CONNECTIONS TO MOTORS AND OTHER DEVICES SUBJECT TO VIBRATION
CONDUIT FITTINGS AND BOXES
1. INTERIOR OUTLET BOXES SHALL BE STANDARD GALVANIZED SHEET STEEL TYPE, NOT LESS THAN 14
GAUGE IN THICKNESS, WITH KNOCKOUT OPENINGS, EXTENSIONS, PLASTER RINGS AND COVER
PLATES TO ACCOMMODATE THE DEVICES INSTALLED. COVER PLATES SHALL BE SMOOTH PLASTIC TO
MATCH DEVICE COLOR. USE STEEL PLATES WITH ROUNDED CORNERS FOR SURFACE BOXES.
OUTDOOR (WET LOCATION) OUTLET BOXES SHALL BE CAST ALUMINUM TYPE WITH DEVICE COVERS
TO SUIT.
2. OUTLET BOXES SHALL NOT BE LESS THAN 4 INCHES SQUARE, 1-1/2 INCHES DEEP.
3. COUPLINGS AND CONNECTORS FOR EMT SHALL BE DIE CAST ZINC OR STEEL. BUSHING SHALL BE
GROUNDING TYPE WITH INSULATING PLASTIC INSERT.
4. FLOOR JUNCTION BOX WITH COVER SHALL BE HUBBELL #S1PFB DEEP BOX WITH #S1TFCAL
ALUMINUM FINISH COVER (FOR TILE APPLICATION) OR #S1CFCAL ALUMINUM FINISH COVER (FOR
CARPET APPLICATION), SUBPLATE S1SP. PROVIDE DEVICES AS INDICATED ON THE DRAWINGS.
5. POKE THROUGH TO BE HUBBELL S1PTFIT WITH #S1TFCAL ALUMINUM FINISH COVER (FOR TILE
APPLICATION) OR #S1CFCAL ALUMINUM FINISH COVER (FOR CARPET APPLICATION), SUBPLATE S1SP.
PROVIDE DEVICES AS INDICATED ON THE DRAWINGS.
6. ALL COVER PLATE FOR WALL SWITCHES AND RECEPTACLES SHALL BE WHITE.
HOMERUN TO PANEL AND CIRCUIT INDICATED
FR I A R
I.
(ALL SYMBOLS SHOWN ARE NOT
NECESSARILY USED ON THE DRAWINGS)
Date
ELECTRICAL
SPECIFICATIONS,
SYMBOLS AND
DEMOLITION PLAN
07-01-16
ELECTRICAL DEMOLITION PLAN
Drawn By
SCALE: 1/4" = 1'-0"
Checked By
GRD
MTB
Sheet
E100
C.
REFER TO THE MECHANICAL PLANS FOR EXACT LOCATION OF MECHANICAL EQUIPMENT AND REQUIRED ELECTRICAL
CONNECTIONS.
IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS, THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR
OBTAINING "AS BUILT" DRAWINGS FROM THE SUBCONTRACTORS AND SUBMITTING SAME TO NEXTORE PROJECT MANAGER.
F.
IT IS THE E.C.'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM
(WITH-IN 10%).
SEE ARCHITECTURAL ELEVATIONS FOR ADDITIONAL INFORMATION ON PLACEMENT OF OUTLETS & SWITCHES.
H.
ANY PENETRATIONS THROUGH FIRE-RESISTANT/RATED WALLS, PARTITIONS, FLOORS, AND CEILINGS SHALL BE FIRESTOPPED
USING APPROVED METHODS TO MAINTAIN THE FIRE RESISTANCE RATING.
I.
RECEPTACLE CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS FROM
101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS FROM 151'-0" TO 250'-0" IN
LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS ABOVE 250'-0" IN LENGTH SHALL UTILIZE #6
CONDUCTORS MINIMUM.
DUCTWORK AND PIPING SHALL NOT BE ROUTED OVER ELECTRIC PANELS OR TRANSFORMERS.
K.
IT IS THE RESPONSIBILITY OF THE E.C. TO REVIEW ALL ARCHITECTURAL DRAWINGS, ELECTRICAL DRAWINGS AND NOTES TO
INSURE THAT ALL ELECTRICAL REQUIREMENTS ARE MET.
L.
ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES AND ORDINANCES.
M.
ALL OUTLETS IN THE LENS PROCESSING ROOM ARE TO BE LABELED WITH PANEL AND CIRCUIT NUMBER.
N.
THE E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO
CONNECTION.
O.
ALL TELEPHONE CABLING/DATA CABLING TO BE RUN IN CONDUIT TO 6" ABOVE CEILING. PROVIDE 6' OF EXTRA CABLING AT
ALL TELEPHONE/DATA HEAD END LOCATIONS.
P.
ALL CABLING SHALL BE PLENUM RATED. RUN PHONE/DATA CABLING COMPLETELY IN CONDUIT IF LOCAL
CODES/MUNICIPALITIES REQUIRE IT (FIELD VERIFY). ALL CABLING SHALL BE ROUTED AWAY FROM ALL ELECTRIC EQUIPMENT
(WITH-IN 18") AND SECURED TO STRUCTURE ABOVE.
4
3
2
OR
AND
AND
SYSTEMONE SUB-PLATE
HUBBELL S1SP4X4
SYSTEMONE SUB-PLATE
HUBBELL S1SP
S1CFCAL (CARPET) /
S1TFCAL (TILE)
S1CFCAL (CARPET) /
S1TFCAL (TILE)
B
ALL CABLING TO BE PLENUM RATED.
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
FLOOR BOX AND POKE THRU DETAIL
2016-026A
SCALE: NONE
Seal
DATA INTERCONNECTION RISER
SCALE: NONE
1
8
ALL DATA/PHONE CABLING MUST BE SEPARATELY COLOR CODED AND PROPERLY IDENTIFIED W/ NUMBER AND/OR COLOR
SYSTEM AT BOTH ENDS.
SYSTEMONE FLOOR
BOX HUBBELL S1PFB
SYSTEMONE FLOOR
BOX HUBBELL S1PFB
NOTE: ONLY DATA CONDUIT IS SHOWN ON THIS RISER.
SEE PLAN FOR POWER CONDUITS.
A-13
EXTG
VESTIBULE
N.I.C.
LCI-GH30
LCI-GH16
GS-FN02B
GS-FN09
A-13
6
(TYP)
1
A-20
EQ112
SE-OD01-L
A-6
3
A-6
EQ6A
EQ1
GFI
A-6
SE-OD02
SE-OD03
OPTOS 1
EQ100A
GS-FN08B
SE-TOWEL-C
BOH-UP24
GS-CL02-R
EQ102
NAME:
9
EXTG
MECH
J
DATE:
N.I.C.
A-15
EXTG
ELEV LOBBY
CASHWRAP
107
Engineer
J
BOH-UP24
GS-PW95
A-19
1
1
SK3
A-19,
21, 23
WAITING
GS-FN02B
106
GS-PW94
LCI-GH30
GS-FN04
BOH-UP24
EQ6 EQ22A
A-7
RECESSED ELECTRIC PANEL
GS-PW10
GS-PW01A_L
GS-PW01A_R
A
01
-PW
11
GS
W
-P
31
_C
GS
1A P W
W0 GSP
GS _L
A
01
W
P
S
G
G
1
W0
S-P
OPTICAL
STATION
N.I.C.
104
THE EXISTING SYSTEM DOES NOT HAVE DETECTION OR A/V DEVICES IN THE SALES FLOOR. THEREFORE, NO
NEW DEVICES ARE BEING ADDED INTO THIS MINOR REMODEL.
CONTRACTOR SHALL COORDINATE WORK AND COST REQUIRED WITH LANDLORDS FIRE ALARM VENDOR
FOR ADDED DEVICE IN OFFICE SPACE.
A-3
1
GS_L
01A
W
P
S
PW0
1
PW1
R
1A_
PW0
GS-
01A_L
GS-PW
01A_CW01A_R
GS-PW
A_C W31 GS-P
1
0
W
GS-P
GS-P
A-8
7
Seal
11
15
20W
CW
4
5
RETAIL
2
3
101
A-5
A-18
A-19
07
-FN
GS
1
A-21,
23
7
-LF
GS
0W
07
-FN
GS
GS-
A-5
A-18
2 16
GS
2
LF5
GS-LF50
GS-
LF21
GS-LF50
2 3
A-16
1
GS-LF11
GS-LF52
GS-LF53
ELECTRICAL POWER PLAN
SCALE: 1/4" = 1'-0"
07/07/2016
REG NO:
123816
Nextore project
Number
73052
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
ELECTRICAL POWER
AND LOW VOLTAGE
PLAN AND DETAILS
PLAN NORTH
1
DATE:
1
2 16
GS-LF13
Michael B. Walsh
LF10
07
-FN
GS
NAME:
GS-LF53
GS-LF50
1
2
16
3
1
A-5
A-18
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Job# 2016128.00
1
R
1A_
GS-
2
07
-FN
GS
R G
A_
PW1
_C
7
EXTG
SALES AREA
1
_L
01A
_75
S-PW
1
G
6
PW
A-18
GSGS-
10
-PW
GS
GS-
5
J
A-17
(TYP)
6
14
10
A-5
7
10
GS-PW
W91
EQ8C
PROVIDE POWER, TELEPHONE AND DATA CONDUIT WITHIN FLOOR, BETWEEN FIXTURE AND NEAREST WALL AS
INDICATED ON PLANS. METHOD OF CORE DRILLING SHALL BE PER BUILDING REQUIREMENTS. ALL CORE DRILL
REQUIREMENTS SHALL BE VERIFIED WITH LANDLORD. CONTRACTOR SHALL SIZE CONDUIT PER NEC. PROVIDE
FOR X-RAY OF FLOOR WHERE REQUIRED BY THE LANDLORD.
BOH-UP24 BOH-UP24
EQ21
GS-FN08B
NEW PANEL "A"
A-16,18
11
GS-PW
A-9
7
GS-P
GS-FN04
1
CORE DRILLING AND TRENCHING NOTE
F
A-22
2
B.
REG NO:
N.I.C.
GS-FN08B
105
N.I.C.
00C
J
GFI BREAKER
A-24
NEW
STOCK
EQ101
EQ105C
13
DATA PRICING NOTES
A.
CLIENT COMMENTS
S1PTFIT POKE THRU
OR
(1) CAT6 (BY OTHERS) FROM FLOOR
BOX AT FIXTURE TO FLOOR BOX AT
CASH DESK IN 3/4" CONDUIT.
N.I.C.
GENERAL NOTES - FIRE ALARM
07/19/16
Architect of Record
(2) CAT6 (BY OTHERS) FROM FLOOR
BOX AT FIXTURE TO FLOOR BOX AT
CASH DESK IN 3/4" CONDUIT.
G.C. SHALL PURCHASE AT LUXOTTICA NATIONAL ACCOUNT AGREED PRICING ALL DISCONNECT ELECTRIC DISTRIBUTION
PANELS, AND FLOOR BOXES. CONTACT LUXOTTICA NATIONAL ACCOUNT REPRESENTATIVE FOR PRICING INFORMATION AND
INCLUDE IN BID
E.C. SHALL INCREASE CONDUIT SIZE BY ONE TRADE SIZE, IF CONDUIT BENDS EXCEED 180 DEGREES.
ELECTRICAL CONTRACTOR, FOR BASE PRICING, IS RESPONSIBLE FOR THE HOMERUNS TO THE MACY'S
EQUIPMENT ROOMS AND IN THE LENSCRAFTERS AREA, THE RACEWAY SYSTEM ONLY.
Description
SUBMIT FOR PERMIT
BOX CALL OUT: STANDARD
S1PT4X4FIT POKE THRU
(3) CAT6 (BY OTHERS) FROM FLOOR
BOX AT FIXTURE TO FLOOR BOX AT
CASH DESK IN 1" CONDUIT.
NOTE: SEE POWER PLAN FOR ADDITIONAL RECEPTACLES
AND POWER CONNECTIONS.
A
BOX CALL OUT: 4X4 FITTING
(1) CAT6 (BY OTHERS) FROM FLOOR
BOX AT FIXTURE TO FLOOR BOX AT
CASH DESK IN 3/4" CONDUIT.
CONTACT
A-4
LENS
1.
2.
By
1
EXTG
STAIRS
SEE DATA RISER ON THIS SHEET FOR ADDITIONAL INFORMATION.
Date
07/07/16
1
THREE STANDARD FLOOR BOXES AT
CASH DESK. TWO FOR DATA, ONE
FOR POWER (ONE DOUBLE DUPLEX)
IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS, THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR
OBTAINING "AS BUILT" DRAWINGS FROM THE SUBCONTRACTORS AND SUBMITTING SAME TO NEXTORE PROJECT MANAGER.
V.
Mark
LCI-GH30
CONDUIT AND OUTLETS FOR SECURITY, DATA, TELEPHONE, AND ELECTRIC MAY REQUIRE REMOVAL OF CONCRETE SLAB OR
ROUTING OF CONDUIT UNDER FLOOR IN SPACE BELOW.
ANY PENETRATIONS THROUGH FIRE-RESISTANT/RATED WALLS, PARTITIONS, FLOORS, AND CEILINGS SHALL BE FIRESTOPPED
USING APPROVED METHODS TO MAINTAIN THE FIRE RESISTANCE RATING.
Revisions:
INSTALL IN (ONE) 1" C AND (ONE) 1 1/2" C, FROM WALL TO FLOOR
BOX/POKE THRU
1
J.
U.
Macy's Store Number: (687)
INSTALL IN (ONE) 1" C AND (ONE) 1 1/2" C, FROM WALL TO FLOOR
BOX/POKE THRU
1
(1) CAT6 (BY OTHERS) FROM
WALL BOX AT BACKWRAP TO
FLOOR BOX AT CASH DESK IN 1"
CONDUIT.
1
G.
T.
1
1
E.
S.
+1 (516) 393-2484
INSTALL IN 1" C
1
ALL TEMPORARY WIRING SHALL BE REMOVED WHEN PERMANENT POWER IS AVAILABLE.
R.
1
(2) CAT6 (BY OTHERS) FROM
WORK COUNTER TO FLOOR BOX
AT CASH DESK
INSTALL IN 1" C
+1 (513) 765-6000
p
1
D.
Q.
2
p
6 Creamery Brook, East Granby, CT 06026
FR I A R
FLEXIBLE CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO MILLWORK, INTERIOR LIGHTING FIXTURES, AND
EQUIPMENT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE 12'-0".
CONTRACTOR TO RUN (1) CAT6 TO MACY'S
TELEPHONE ROOM AND (1) CAT6 TO MACY'S
P.O.S. / DATA CLOSET FOR MACY'S USE.
LEAVE 12FT COILED IN ROOM.
1
(4) CAT6 (BY OTHERS) FROM FLOOR
BOX AT FIXTURE TO FLOOR BOX AT
CASH DESK IN 1" CONDUIT.
ALL MOUNTING HEIGHTS FROM THE CENTERLINE OF THE BOX TO THE FINISHED FLOOR ARE AS FOLLOWS, UNLESS NOTED
OTHERWISE ON PLAN: SWITCHES-48", ELECTRICAL/TELEPHONE/DATA OUTLETS-18", TOP OF PANELBOARDS-6'-6",
TIMECLOCKS-5'-0". FOR ALL LENS PROCESSING ROOM OUTLET MOUNTING HEIGHTS SEE EQUIPMENT WIRING SCHEDULE.
B.
AT CASH DESK IN
EXAM AREA
5
GENERAL NOTES
A.
DOCTOR'S SWITCH
4000 Luxottica Place, Mason, OH 45040
a
GS-LF92
15.
16.
AT WORK COUNTER, (2)
DATA INSTALLED AT 18"
AFF AND (2) DOUBLE
DUPLEX OUTLETS AT 18"
GS-LF52
10.
11.
12.
13.
14.
OPTOS
1
GS-CW20
8.
9.
3
a
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
LCM-GR32
4.
5.
6.
7.
1
CONTRACTOR TO RUN (2) CAT6 TO MACY'S
TELEPHONE ROOM AND (1) CAT6 TO MACY'S
P.O.S. / DATA CLOSET FOR LENSCRAFTER'S
USE. LEAVE 12FT COILED IN ROOM.
SE-GH-CHART
3.
INSTALL AT 18" AFF IN DOCTOR'S
OFFICE.
EQ109B
2.
PROVIDE DIRECT CONNECTION IN WALL TO SERVE TANKLESS WATER HEATER. CONNECTION TO BE 25A, 120V, SINGLE
PHASE. CIRCUIT AS INDICATED. COORDINATE LOCATION WITH PLUMBING CONTRACTOR.
PROVIDE TRENCHING FOR POWER AND TELE/DATA TO SELECT TABLE. E.C. SHALL VERIFY ALL TRENCHING
REQUIREMENTS WITH THE LANDLORD PRIOR TO THE START OF WORK. PROVIDE DEVICES AND DEVICE QUANTITIES AS
SPECIFIED ON PLANS. E.C. SHALL COORDINATE INSTALLATION AND CONNECTION REQUIREMENTS WITH FURNITURE
MANUFACTURER REPRESENTATIVE.
PROVIDE "STANDARD" FLOOR BOX/POKE THRU AT THIS LOCATION - SEE DETAIL B/E200 AND THE DATA
INTERCONNECTION RISER.
PROVIDE JUNCTION BOX AND CIRCUIT FOR EYE EXAM SIGN.
PROVIDE JUNCTION BOX ABOVE CEILING FOR LENSCRAFTERS SIGN.
VERIFY MOUNTING HEIGHTS OF OUTLETS WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN.
CONNECT CIRCUIT TO MACY'S LIGHTING CONTROL SYSTEM. SEE DETAIL A/E201. VERIFY SPECIFIC REQUIREMENTS
WITH MACY'S.
1
INSTALL RECESSED RECEPTACLE AS SHOWN ON ARCHITECTURAL ELEVATION FOR THE DIGITAL EYE CHART.
ROUTE ONE 3/4" CONDUIT TO ABOVE CEILING FROM EMPTY 4X4 JUNCTION BOX WITH MUDRING INSTALLED AT
HEIGHT EQUIVALENT TO ADJACENT POWER OUTLET. BUSH CONDUIT END AND PROVIDE PULL STRING.
ROUTE CONDUIT 6" ABOVE CEILING AND BUSH END. TYPICAL.
SEE DATA INTERCONNECTION RISER FOR DATA CONDUIT SIZES. PROVIDE PULL STRING. TYPICAL.
NOT USED.
COORDINATE LOCATION OF RECEPTACLE INSTALLATION WITH ACCESS PANEL AND PUMP.
1
RECEPTACLE AND JUNCTION BOX SERVES DIGITAL SIGNAGE. SEE ELEVATION ON ARCHITECTURAL SHEETS. VERIFY
EXACT LOCATION OF ROUGH IN WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN.
ROUTE 1" CONDUIT FOR POWER.
PROVIDE "4X4 FITTING" FLOOR BOX/POKE THRU AT THIS LOCATION. SEE DETAIL B/E200 AND THE DATA
INTERCONNECTION RISER.
EQ108
1.
(2) CAT6 TO MACY'S PHONE BOARD.
(1) CAT6 (BY OTHERS) 1
BETWEEN JACKS
KEY NOTES - ELECTRICAL PLAN
EQ119
XX
NOTE:
INSTALL CONDUITS IN SAME TRENCH (WHEN TRENCHING). FEED DATA WIRING
THROUGH DATA JUNCTION BOXES AND SHARE CONDUITS WITH OTHER DATA
WIRE - DO NOT SPLICE AND DO NOT ROUTE DATA/COMM IN THE SAME
RACEWAY AS POWER.
SEE SHEET E400 FOR ADDITIONAL INFORMATION ON CASEWORK.
Date
07-01-16
Sheet
Drawn By
GRD
Checked By
MTB
E200
TYPE
AD
PART-NUMBER
MANUFACTURER
METALUX
INPUT WATTS
34.5
22ALNG-LD4-35-UNV-L835-CD1-U
LAMP QTY
N/A
LAMP TYPE
INTEGRAL LED, 3482 LUMENS
DESCRIPTION
MOUNTING
RECESSED 2X2 LED TROFFER
A.
CEILING TYPE
RECESSED
ACT
AD
AD- EM
22ALNG-LD4-35-UNV-L835-CD1-U
-EL14W
METALUX
AD-EM
X2
2T-S
TL
4T-S
TL
6T-S
TL
8T-S
TL
12T-S
TL
34.5
N/A
INTEGRAL LED, 3482 LUMENS
14W EMERGENCY - 1400 LUMENS
RECESSED 2X2 LED TROFFER WITH EMERGENCY BATTERY
BACKUP.
RECESSED
LIGHT ALARMS
SPLEDWRCD
3
N/A
LED INCLUDED
RECESSED EXTRUDED ALUMINUM EDGE LIT EXIT SIGN WITH
RED LETTERS FOR CEILING OR WALL MOUNTING RED LED
INCLUDED. TO BE RECESSED MOUNTED U.N.O. (FOR NYC
OR CHICAGO CONFIRM WITH MANUF). PROVIDE
CURRENT LIMITER WHERE REQUIRED.
2T-S
JUNO
T2WH
-
-
TRACK ONLY - SEE TRACK HEAD
2 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
JUNO
T690WH
18
1
GE LED18D38W3930/25; 18W; 92 CRI;
3000K; PAR38, MED BASE
GIMBAL STYLE LAMP-HOLDER, WHITE
4T-S
JUNO
T4WH
-
-
TRACK ONLY - SEE TRACK HEAD
4 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
JUNO
T690WH
18
1
GE LED18D38W3930/25; 18W; 92 CRI;
3000K; PAR38, MED BASE
GIMBAL STYLE LAMP-HOLDER, WHITE
6T-S
JUNO
T6WH
-
-
TRACK ONLY - SEE TRACK HEAD
6 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
JUNO
T690WH
18
1
GE LED18D38W3930/25; 18W; 92 CRI;
3000K; PAR38, MED BASE
GIMBAL STYLE LAMP-HOLDER, WHITE
8T-S
JUNO
T8WH
-
-
TRACK ONLY - SEE TRACK HEAD
8 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
JUNO
T690WH
18
1
GE LED18D38W3930/25; 18W; 92 CRI;
3000K; PAR38, MED BASE
GIMBAL STYLE LAMP-HOLDER, WHITE
12T-S
JUNO
T12WH
-
-
TRACK ONLY - SEE TRACK HEAD
12 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
JUNO
T690WH
18
1
GE LED18D38W3930/25; 18W; 92 CRI;
3000K; PAR38, MED BASE
GIMBAL STYLE LAMP-HOLDER, WHITE
X2
ACT
TRACK
SEE FOOTNOTE 1
TRACK
C.
IT SHALL BE THE E.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE E.C.
SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR.
D.
EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS.
EXIT/EMERGENCY LIGHTS AT DOOR TO NON-SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED
ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT
MANAGER FOR DIRECTION.
E.
WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, E.C. SHALL ARRANGE CIRCUITS TO AVOID THE
USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL
CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR
GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE,
IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION.
F.
E.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION
PERIOD.
G.
LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. LIGHTING
CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTING
CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. LIGHTING
CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM.
SEE FOOTNOTE 1
I.
SEE FOOTNOTE 1
SEE FOOTNOTE 1
TRACK
J.
FOOTNOTES:
1. SEE PLANS FOR TRACK LOCATIONS. PROVIDE CURRENT LIMITERS AND PENDANTS WHERE CALLED FOR ON THE PLANS.
XX
CONNECT TO NEAREST MACY'S
120V MERCHANDISE LIGHTING
CIRCUIT SWITCHED WITH MACY'S
LIGHTING CONTROL SYSTEM.
120V COIL
LOAD DESCRIPTION
CASEWORK AND SIGNS
WALL SHELF LIGHTING
1.
ALL NIGHT (NL) LUMINAIRES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING
H.
TRACK
EMERGENCY (EM) LUMINAIRES SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT" TO PROVIDE
CONTINUOUS POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF.
B.
SEE FOOTNOTE 1
TRACK
ENERGY CODE - COMMISSIONING
COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE OFFICE AREA:
1.1.
1.2.
1.3.
2.
OCCUPANCY SENSORS DETECT MOTION AND ENERGIZE THE LOCAL SWITCHING.
LOCAL SWITCHING IS DIMMABLE, ALLOWING A RANGE OF DIMMING FROM 5% TO 100%.
OCCUPANCY SENSORS DE-ENERGIZE AFTER NO MOTION IS DETECTED AFTER A 30 MINUTE DELAY.
2.2.
2.3.
SIGNS, PERIMETER SHELVING AND SALES FLOOR DISPLAY CABINETS ARE ENERGIZED AND
DE-ENERGIZED WITH THE MACY'S DISPLAY LIGHTING CONTROL.
SUPPLEMENTAL TRACK LIGHTING IS LIMITED TO 125% OF THE CONNECTED WATTAGE OF TRACK
HEADS.
SUPPLEMENTAL TRACK LIGHTING IS CONTROLLED WITH THE MACY'S ACCENT LIGHTING CONTROL.
E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK
PRIOR TO CONNECTION.
M.
FOR ALL REMODELS, RETROFIT ALL EXISTING FLUORESCENT LIGHTS WITH T12 FIXTURES TO T8, INCLUDING
BALLASTS AND LAMPS
XX
1.
CIRCUIT
A-5, 9
PROVIDE OCCUPANCY SENSOR TO CONTROL LIGHTS IN AREA. CONNECT LOAD SIDE OF SENSOR POWER
PACK TO LINE SIDE OF AREA SWITCHING. AREA SWITCHING DOES NOT RECEIVE POWER UNLESS THE
SENSOR POWER PACK DETECTS MOTION. SET SENSOR TO 30 MINUTE TIME OUT AND MAXIMUM
SENSITIVITY. SEE B/E201.
CLIENT COMMENTS
2.
EMERGENCY FIXTURES SHALL HAVE EMERGENCY BATTERY BACK UP OR EMERGENCY BALLAST AND BE
SERVED BY UNSWITCHED LEG OF LOCAL CIRCUIT TO PROVIDE CONTINUOUS ILLUMINATION PER LIFE
SAFETY CODE..
3.
LIGHTING IN THIS AREA IS FROM MACY'S STORE.
4.
SPEAKERS ARE EXISTING TO REMAIN.
5.
RELOCATED 2X4 FIXTURE.
6.
MATCH EXISTING RECESSED, ADJUSTABLE ACCENT LIGHT. TIE TO EXISTING NEARBY LIGHTING BRANCH
CIRCUIT FOR POWER/CONTROL. VERIFY LOAD DOES NOT EXCEED 1.92KVA ON A 1P-20A, 120V CIRCUIT.
1
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
Seal
3/D
EXTG
VESTIBULE
N.I.C.
(N)
AD
I.C.
(N)
(N)
AD-EM
3/D
TG
IRS
OS
(N)
(N)
AD
EXTG
MECH
OS
(N)
AD
1
NAME:
N.I.C.
1
DATE:
EXTG
ELEV LOBBY
CASHWRAP
SE-OD02
OPTION 1: CONNECT CONTACTOR COIL TO ADJACENT LIGHTING
CIRCUIT CONTROLLED BY MACY'S LIGHTING CONTROL SYSTEM.
WALL SHELF LIGHTING
07/19/16
2016-026A
2
107
X2
(N)
REG NO:
N.I.C.
3/D
(R)
BOH-UP24
CONTACT
LENS
BOH-UP24
GS-CL02-R
SK3
WAITING
105
A-5, 9
N.I.C.
A-3
CONTACTOR TO BE SQUARE D OR EQUAL, 20A CONTACTS,
ELECTRICALLY HELD IN NEMA1 ENCLOSURE. INSTALL ABOVE
CEILING WHERE PERMITTED BY CODE.
X2
(N)
2
106
NEW
STOCK
CIRCUIT
A-1
2
(N)
AD
AD-EM
(N)
5
Engineer
1 OS
(N)
AD
CONNECT TO MACY'S 24V LIGHTING CONTROL
SYSTEM. ROUTE PLENUM RATED WIRING WHERE
REQUIRED. WIRING IS NOT REQUIRED IN
CONDUIT UNLESS THE JURISDICTION REQUIRES IT.
24V COIL
Description
SUBMIT FOR PERMIT
Architect of Record
A-3
GENERALLY, THE LIGHTING CONTROL SYSTEM IS PRESENT IN ANY MACY'S ELECTRIC ROOMS. VERIFY IN FIELD.
VERIFY EXACT REQUIREMENTS WITH MACY'S OPERATIONS.
MICHIGAN AND TOLEDO MACY'S STORES USE ANDOVER CONTROLS (GENERALLY) AND INET (RARELY).
By
KEY NOTES
1
CASEWORK AND SIGNS
Date
07/07/16
1
CONTACTOR TO BE SQUARE D OR EQUAL, 20A CONTACTS,
ELECTRICALLY HELD IN NEMA1 ENCLOSURE. INSTALL ABOVE
CEILING WHERE PERMITTED BY CODE.
LOAD DESCRIPTION
+1 (516) 393-2484
Mark
EMERGENCY AND EXIT LUMINAIRES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST
NATIONAL ELECTRICAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL-VOLTAGE WITH
BATTERY BACKUP (120/277 VOLT INPUT). INSTALL A CENTRAL BATTERY SYSTEM WHERE THE USE OF
INDIVIDUAL BATTERY UNITS ARE PROHIBITED BY LOCAL CODES. IF PLAN LOCATION IS NOT ACCEPTABLE,
IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION.
L.
+1 (513) 765-6000
p
Revisions:
E.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY
NEXTORE. E.C. IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL DIRECTIONAL FIXTURES AFTER
INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS
MAY VARY, IF THIS IS THE CASE, CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT
SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, E.C. SHALL CLOSELY
COORDINATE FIXTURE REQUIREMENTS WITH LUXOTTICA.
E.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE
SYSTEM.
p
6 Creamery Brook, East Granby, CT 06026
Macy's Store Number: (687)
LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE THRU-WIRING
WHEREVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP
CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. LIGHTING FIXTURES SHALL BE
MANUFACTURED TO ACCOMMODATE THRU-WIRING, ANY RELATED COSTS FOR MULTIPLE CONNECTIONS
SHALL BE INCLUDED IN BID.
K.
4000 Luxottica Place, Mason, OH 45040
a
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE SALES AREA:
2.1.
a
(N) OS
1
(N)
AD
3/D
SYMBOL
GENERAL NOTES
FR I A R
LIGHTING SCHEDULE
(N)
AD-EM
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Job# 2016128.00
2
D
5
(E)
(R)
(E)
(E)
(E)
(E)
(E)
RETAIL
101
GENERALLY, THE LIGHTING CONTROL SYSTEM IS PRESENT IN ANY MACY'S ELECTRIC ROOMS. VERIFY IN FIELD.
VERIFY EXACT REQUIREMENTS WITH MACY'S OPERATIONS.
MICHIGAN AND TOLEDO MACY'S STORES USE ANDOVER CONTROLS (GENERALLY) AND INET (RARELY).
(E)
EXTG
SALES AREA
OPTICAL
STATION
N.I.C.
104
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(N)
(E)
(E)
S
(E)
6
(E)
4
(E)
(E)
Seal
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(N)
AD
(E)
(E)
(E)
6
(E)
(E)
1
(E)
(E)
(N)
(E)
(E)
OPTION 2: CONNECT CONTACTOR COIL TO MACY'S LIGHTING
CONTROL SYSTEM.
EX/D1
NAME:
Michael B. Walsh
DATE:
07/07/2016
REG NO:
123816
(E)
3
A
MACY'S LIGHTING CONTROL INTERFACE
ISSUED FOR:
(E)
LIGHT
(E)
(E)
(E)
S
B
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
ELECTRICAL LIGHTING
PLAN AND DETAILS
(E)
SENSOR POWER PACK
UNSWITCHED CIRCUIT
Date
OCCUPANCY SENSOR CONTROL
SCALE: NONE
Client Review
Title
4
AREA LIGHT SWITCH
SENSOR
73052
(E)
(E)
SCALE: NONE
OS
Nextore project
Number
PLAN NORTH
1
LIGHTING PLAN
SCALE: 1/4" = 1'-0"
07-01-16
Sheet
Drawn By
GRD
Checked By
MTB
E201
ONE-LINE DIAGRAM NOTES
FIELD VERIFY ALL CONDITIONS
DESIGN DRAWINGS ARE SCHEMATIC. THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR
TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS
CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD
MODIFICATIONS DUE TO EXISTING CONDITIONS.
THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO
BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID
ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER
OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT GENERAL
CONTRACTORS COST.
BIDDING GENERAL CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES
AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED
IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT
WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY
APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT.
ELECTRICAL LOAD SUMMARY
PANEL "A"
LIGHTING
SHOW WINDOW RECEPTACLE
CONNECTED LOAD
(KW)
DEMAND
FACTOR
2.15
1.25
2.7
0.000
1.0
0.000
.5
SIGN
DEMAND LOAD
(KW)
1.25
100% 10K
50%>10K
1.0
EQUIPMENT
5.2
WATER HEATER
4.8
HVAC
----
-----
15.15
15.7
42
43
TOTAL (AMPS)
3.
PROVIDE NAMEPLATES PER NAMEPLATE DETAIL.
4.
COORDINATE SPACE WITH ALL OTHER TRADES TO MAINTAIN
ALL CODE- REQUIRED CLEARANCES.
5.
REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
6.
THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH NEC
ARTICLE 110.16 FOR LABELING OF PANELS FOR ARC FLASH
HAZARD WARNING AS WELL AS FOLLOWING REQUIRED SAFETY
PRECAUTIONS WHEN SERVICING OR MAINTAINING ELECTRICAL
EQUIPMENT.
1.
MACY'S ELECTRIC ROOM
LENSCRAFTERS
+1 (513) 765-6000
p
+1 (516) 393-2484
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
EXISTING MACY'S ELECTRICAL PANEL IN MACY'S ELECTRICAL
ROOM (SEE MPE-100). FURNISH AND INSTALL NEW 60 AMP 3
POLE BREAKER FOR FEED TO LENSCRAFTERS.
Macy's Store Number: (687)
(4)#6, (1)#8 GND IN 1 1/4" C.
WHERE PERMITTED BY THE
JURISDICTION AND
LANDLORD, MC CABLE CAN
BE USED FOR THIS
INSTALLATION.
ENGRAVED LAMACOID, 5/32"
LETTERS, SECURE TO PANEL
BOARD COVER WITH ADHESIVE
TYPE FASTENER.
A
EXISTING
PANEL
120/208
225A
NEW
PANEL "A"
120/208V
3Ø 60A
MCB
Revisions:
Mark
07/19/16
CLIENT COMMENTS
5.2
4.8
Architect of Record
VOLTAGE DROP CALCULATION
VD = 2 x L x R x I
1000
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
MACY'S PANEL TO PANEL IN SPACE:
DISTANCE TO SPACE:
WIRE SIZE TO SPACE:
AMPS:
VD =
2 x 74 x 0.4 x 45
1000
74 FT.
4#6 (R=0.4)
45
By
Description
SUBMIT FOR PERMIT
1
FLOOR
VOLTAGE DROP TO BE LESS THAN 3%
Date
07/07/16
2.5
2.5
TOTAL (KW)
THE ELECTRICAL CONTRACTOR SHALL VERIFY THE AVAILABLE
FAULT CURRENT WITH THE LANDLORD PRIOR TO BIDDING AND
PROVIDE EQUIPMENT RATED ACCORDINGLY. SUBMIT FAULT
CURRENT CALCULATIONS WITH SHOP DRAWING SUBMITTAL.
:
p
6 Creamery Brook, East Granby, CT 06026
.5
RECEPTACLES
1.25
2.
THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL LANDLORD
REQUIREMENTS PRIOR TO BIDDING & INCLUDE THE COST OF
ALL ASSOCIATED LABOR, MATERIALS, & CHARGES IN HIS BID.
4000 Luxottica Place, Mason, OH 45040
a
FR I A R
LOAD DESCRIPTION
1.
ELECTRIC ONE LINE DIAGRAM
a
2016-026A
Seal
1
= 2.7 V
2.7 V
x 100 = 0.74 %
208 3 V
1
1
NAME:
DATE:
REG NO:
Engineer
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Job# 2016128.00
Seal
NAME:
Michael B. Walsh
DATE:
07/07/2016
REG NO:
123816
Nextore project
Number
73052
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
Title
ELECTRICAL
RISER DIAGRAM AND
PANEL SCHEDULE
Date
07-01-16
Sheet
Drawn By
GRD
Checked By
MTB
E300
CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER)
LF-50 (1) 92" LED STRIP 21W
X
TOTAL 21W
LF-51 (4) 76" LED STRIP 68W
(3) 60W DRIVERS
(1) 48" LED STRIP 11W
TOTAL 79W
LF-52 (6) 76" LED STRIP 102W (4) 60W DRIVERS
(1) 72" LED STRIP 19W
TOTAL 121W
TOTAL 21W
INFORMATION IS PER 4FT SECTION.
TOTAL
XW
EQ109B REFRACTION STAND 120
EQ108
ORIENT OUTLETS
AS SHOWN.
POWER FOR THE END CABINETS "LF-50" IS SUPPLIED FROM MAIN CABINET
"LF-52". THE LED STRIP LIGHTS ARE PRE-INSTALLED BY THE CASEWORK
SUPPLIER WITH A WHIP LEFT FOR LOW VOLTAGE CONNECTION TO A 60W
DRIVER IN "LF-52". ELECTRICAL CONTRACTOR SCOPE IS TO CONNECT THE
LED LIGHTING TO THE DRIVER PRE-INSTALLED CASEWORK "LF52".
ELECTRICAL OUTLET INSTALLED
BY EC AT 15" AFF.
TO LEDs IN CASEWORK. WIRING,
DRIVER AND LEDs ARE INSTALLED
BY CASEWORK SUPPLIER.
LF52: (1) 100W
DRIVER AND (2)
60W DRIVERS
PRE-INSTALLED.
1"
1'-12
2'-0"
60W DRIVER
GS-PW01_R
1'-181"
LF50: (1) 60W DRIVER
PRE-INSTALLED IN "LF-52".
EC TO PLUG DRIVER INTO
RECEPTACLE
CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER)
LF-71 (1) DATA
0W
REQUIRES (1) DATA
FEED AND TWO 20A
(1) DOUBLE DUPLEX 360W
(1) DUPLEX
1300W CIRCUITS BY EC
TOTAL
1660W
LF52
540W
GS-LF71
1'-2"
TOTAL
120
2.1
X
X
EQ103
LENSOMETER
120
1
X
EQUIPMENT IS NOT IN USE IN THIS PLAN.
1
GFI
EQ119
EQ100A
OPTOS
42"
3
EQ6A
Mark
Date
EQ108
Description
SUBMIT FOR PERMIT
07/19/16
CLIENT COMMENTS
1
EQUIPMENT ELECTRICAL/MECHANICAL REQUIREMENTS
NOTES
ID
DESCRIPTION
VOLT AMP BTU
NEMA #5 - 20R
EQ6
LENSOMETER (MANUAL) 120
1
X
Architect of Record
EQ101
TONOMETER
120
1
X
THIS EQUIPMENT PLUGS INTO EQ100C
EQ22
FRAME WARMER
120
13
X
NEMA #5 - 20R, DEDICATED OUTLET
EQ102
REFRACTOMETER
120
1
X
THIS EQUIPMENT PLUGS INTO EQ100C
EQ21
EYE NET STATION
120
2
X
NEMA #5 - 20R DC
EQ105C OCULUS
120
1.1
X
THIS EQUIPMENT PLUGS INTO EQ100C
EQ8C
FRAME TRACER
120
2.1
X
NEMA #5 - 20R DC
EQ104
120
0.5
X
THIS EQUIPMENT PLUGS INTO EQ100C
EQUIPMENT IS NOT IN USE IN THIS PLAN.
X
EMPLOYEE TIME CLOCK 120
1.1
X
NEMA #5 - 20R
120
2
X
NEMA #5 - 20R; EQUIPMENT IS NOT IN USE IN THIS PLAN.
EQ24
ULTRASONIC CLEANER 120
1
X
NEMA #5 - 20R; EQUIPMENT IS NOT IN USE IN THIS PLAN.
EQ43
SPECTROMETER
1
X
NEMA #5 - 20R; EQUIPMENT IS NOT IN USE IN THIS PLAN.
VISION TESTER
05C
EQ1
EQ
120
EQ
By
07/07/16
EQ109B
EQ11B DIAMOND EDGER
LEAVING THE CASH DESK:
PROVIDE CONDUITS AS SHOWN ON
THE DATA INTERCONNECTION RISER,
SHEET E200.
ASSOCIATES INC.
281 Farmington Avenue
Farmington, CT. 06032
2016-026A
Seal
D
GS-FN07
EQ21
GS-LF70
EQ
+1 (516) 393-2484
Revisions:
EQ
SUPPLY FOR THE CASH DESK:
PROVIDE CONDUITS AS SHOWN ON THE DATA
INTERCONNECTION RISER, SHEET E200.
EQ
KERATOMETER
EQUIPMENT ELECTRICAL/MECHANICAL REQUIREMENTS
ID
DESCRIPTION
VOLT AMP BTU
NOTES
EQ100C TRIPLE POWER TABLE 120
1
X
THIS TABLE PLUGS INTO THE WALL
CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER)
LF-70 (1) DATA
0W
REQUIRES (1) DATA
(1) DOUBLE DUPLEX 360W FEED AND TWO 20A
(1) DUPLEX
180W CIRCUITS BY EC
EQ
GS-FN07
EQ119
EC TO PROVIDE A SINGLE FLOOR
BOX (WITH DIVIDER) CENTERED IN
AREA SHOWN. FLOOR BOX TO HAVE
DUPLEX RECEPTACLE AND DATA
OUTLET. PROVIDE CONDUITS AS
SHOWN ON THE DATA
INTERCONNECTION RISER, SHEET
E200.
ROUTE CORD UP CABINET LEG. CORD
IS SUPPLIED BY CASEWORK SUPPLIER
AND INSTALLED BY THE EC.
CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER)
CW-20 (3) DATA
0W
REQUIRES (3) DATA
(2) DOUBLE DUPLEX 720W FEED AND TWO 20A
(1) DUPLEX
180W CIRCUITS BY EC
TOTAL
900W
THREE FLOOR BOXES BY EC. ONE FOR POWER,
TWO FOR LOW VOLTAGE. SEE POWER PLAN
AND DATA INTERCONNECTION RISER FOR
ADDITIONAL INFORMATION.
X
LF13
LF50
GS-PW10
GS-PW01_C
LF50
GS-PW11
GS-PW01_C
+1 (513) 765-6000
p
INSTALL OUTLET 8" BELOW CEILING
FLOOR BOX BY EC
60W DRIVER
p
6 Creamery Brook, East Granby, CT 06026
Macy's Store Number: (687)
LF50: (1) 60W DRIVER
PRE-INSTALLED IN "LF-52".
60W DRIVER
60W DRIVER
4000 Luxottica Place, Mason, OH 45040
a
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
3
1'-2"
100W DRIVER
a
N/A
EQ118C
ELECTRICAL OUTLET INSTALLED
BY EC AT 18" AFF.
REQUIRES DATA
120
ACCESS HOLE IN
FURNITURE CROSS
MEMBER BETWEEN
FURNITURE LEGS
DOUBLE DUPLEX RECEPTACLE PRE-INSTALLED IN CABINET BY CASEWORK
SUPPLIER. WIRING FROM RECEPTACLE TO LED DRIVER AND ASSOCIATED LED
STRIP LIGHTS IS PRE-INSTALLED. ELECTRICAL CONTRACTOR SCOPE IS TO
PROVIDE A FLOOR BOX AND PLUG IN THE CASEWORK TO THE FLOOR BOX.
X
EQ100A OPTOS
EQ101
TO LEDs IN CASEWORK. WIRING,
DRIVER AND LEDs ARE INSTALLED
BY CASEWORK SUPPLIER.
OUTLET
DOORS
PATIENT CARE
2.1
FR I A R
(1) 60W DRIVER
EQUIPMENT ELECTRICAL/MECHANICAL REQUIREMENTS
ID
DESCRIPTION
VOLT AMP BTU
NOTES
EQ6A
LENSOMETER (AUTO) 120
1
X
NEMA #5 - 20R
EQ100C
TOTAL 42W
PW-11 (1) 92" LED STRIP 21W
CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER)
LF-13 (1) X" LED STRIP XW
(1) 100W DRIVER
EQ1
02
CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER)
PW-10 (2) 92" LED STRIP 42W
(1) 60W DRIVER
EQ22A
EQ8C
EQ6
GS-CW20
GS-FN07
EC TO PROVIDE TWO FLOOR BOXES
CENTERED IN AREA SHOWN. FLOOR
BOXES TO HAVE DUPLEX RECEPTACLE
AND DATA OUTLET. PROVIDE
CONDUITS AS SHOWN ON THE DATA
INTERCONNECTION RISER, SHEET
E200.
EQ
EQ
THREE FLOOR BOXES BY EC.
ONE FOR POWER, TWO FOR
LOW VOLTAGE.
GS-FN07
NAME:
DATE:
REG NO:
Engineer
CASEWORK ELECTRICAL
LF-71 (1) DATA
(1) DOUBLE DUPLEX
(1) DUPLEX
TOTAL
2'-0"
CASEWORK ELECTRICAL
CW-20 (3) DATA
(2) DOUBLE DUPLEX
(1) DUPLEX
TOTAL
REQUIRES (1) DATA
FEED AND TWO 20A
CIRCUITS BY EC
EQ
EQ
EQ
LEAVING THE CASH DESK:
PROVIDE CONDUITS AS SHOWN ON
THE DATA INTERCONNECTION RISER,
SHEET E200.
TOTAL
EQ
GS-CW20
GS-FN07
GS-FN07
LENSCRAFTERS
THREE FLOOR BOXES BY EC.
ONE FOR POWER, TWO FOR
LOW VOLTAGE.
1
1
6 8
9
9
1
6 8
1
100W LED DRIVER INSTALLED BY
CASEWORK MANUFACTURER
RECEPTACLE IN WALL BEHIND
UNIT INSTALLED AT 54" AFF TO
CENTERLINE.
Michael B. Walsh
DATE:
07/07/2016
REG NO:
123816
Nextore project
Number
73052
ISSUED FOR:
Client Review
LL Approval
DOB Permit
Bid
DOB Permit - Re-Submit
Construction
6 8
6 8
9
CASEWORK DETAILS
1
1
6 8
2
2
3
3
Title
5 7
2
4
BACKLIT LENSCRAFTERS SIGN
(30W ESTIMATED LED LOAD)
NAME:
9
5 7
3
20W
LED POWER CONNECTOR
INSTALLED BY CASEWORK
MANUFACTURER
EC TO PROVIDE TWO FLOOR BOXES
CENTERED IN AREA SHOWN. FLOOR
BOXES TO HAVE DUPLEX RECEPTACLE
AND DATA OUTLET. PROVIDE
CONDUITS AS SHOWN ON THE DATA
INTERCONNECTION RISER, SHEET
E200.
EQ
6 8
5 8
CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER)
LF-90 (2) 20" LED STRIP 20W
(1) 100W DRIVER
GS-LF70
EQ
1
EQ
SUPPLY FOR THE CASH DESK:
PROVIDE CONDUITS AS SHOWN ON THE DATA
INTERCONNECTION RISER, SHEET E200.
GS-FN07
GS-FN07
ALL POWER WIRING IS TO BE IN METAL RACEWAY. SECURE RACEWAY TO INSIDE OF
FURNITURE. COORDINATE WORK WITH THE GC.
811 Middle Street
Middletown, CT 06457
Tel. (860) 632−1682
Fax. (860) 632−1768
Job# 2016128.00
0W
REQUIRES (1) DATA
360W FEED AND TWO 20A
180W CIRCUITS BY EC
540W
1'-2"
EQ
THREE FLOOR BOXES BY EC. ONE FOR POWER,
TWO FOR LOW VOLTAGE. SEE POWER PLAN
AND DATA INTERCONNECTION RISER FOR
ADDITIONAL INFORMATION.
ELECTRICAL CONTRACTOR IS TO PROVIDE AND INSTALL ALL ELECTRICAL EQUIPMENT
SHOWN IN THE DETAILS. NO WORK IS PROVIDED BY THE CASEWORK
MANUFACTURER. THE DATA CABLING IS THE ONLY WIRING NOT IN THE ELECTRICAL
CONTRACTOR'S SCOPE.
CASEWORK ELECTRICAL
LF-70 (1) DATA
(1) DOUBLE DUPLEX
(1) DUPLEX
TOTAL
0W
REQUIRES (3) DATA
720W FEED AND TWO 20A
180W CIRCUITS BY EC
900W
Seal
GS-LF71
ELECTRICAL LEGEND
DESCRIPTION
#
1
MC CABLE, 12/2 w/GROUND, 12 AWG
2
MC CABLE, 12/3 w/GROUND, 12 AWG
3
4X4 JUNCTION BOX
4
CORD & PLUG. ONE PER CIRCUIT. 20A RATING, CONTINUOUS DUTY.
5
DUPLEX 20A RECEPTACLE
6
DOUBLE DUPLEX, 20A RECEPTACLE
7
FED BY CIRCUIT #1
8
FED BY CIRCUIT #2
9
SINGLE GANG BOX WITHOUT A COVER FOR DATA (DATA WIRING BY OTHERS).
0W
360W
1300W
1660W
4
3
4
4
3
3
4
4
Date
07-01-16
Sheet
Drawn By
GRD
Checked By
MTB
E400