G:\Projects\Lens Crafters\2016-026A Galleria, Houston, TX\SENT
Transcription
G:\Projects\Lens Crafters\2016-026A Galleria, Houston, TX\SENT
Drawings for: a 4000 Luxottica Place, Mason, OH 45040 p +1 (513) 765-6000 a 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 4000 Luxottica Place Mason, Ohio 45040 GALLERIA AT HOUSTON HOUSTON, TX GENERAL CONTRACTOR NOTES 1. BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY: A. THE GC SHALL CONTACT THE NEXTORE P.M. OR THE PERMIT EXPEDITOR TO SECURE THE PERMIT. PERMIT SHALL BE MOUNTED IN A VISIBLE LOCATION AT THE SITE. PERMITS SHALL BE PAID FOR BY THE GC AND SUBMITTED TO TENANT AS A NET COST. B. THE GC SHALL ARRANGE FOR ALL REQUIRED INSPECTIONS. C. THE GC SHALL DETERMINE IF THE INSPECTORS WILL BE CHECKING LAB / LENS PROCESSING ROOM EQUIPMENT FOR UL OR ETL LABELS AND NOTIFY THE CONSTRUCTION MANAGEMENT TEAM NO LATER THAN 4 WEEKS BEFORE "PUNCH". D. IF REQUIRED, A "TEMPORARY C OF O" OR BUILDING DEPARTMENT APPROVAL SHALL BE RECEIVED TO SET DOWN EQUIPMENT. A. 'DOCUMENTS', AS USED HEREIN, SHALL COMPRISE THE ENTIRE INTEGRATED SET OF ALL WRITTEN INSTRUMENTS RELATED TO THE PROJECT, INCLUSIVE OF, BUT NOT EXCLUSIVE TO, ALL CONTRACTS, SUBCONTRACTS, DRAWINGS, SKETCHES, MEMORANDA, ADDENDA, SPECIFICATIONS, MANUALS, POLICIES, RULES AND REGULATIONS, LANDLORD DESIGN CRITERIA, SUBMITTALS, SHOP DRAWINGS, PERMITS, APPROVALS, REGULATIONS AND CODES. 'PROJECT', AS USED HEREIN, SHALL REFER TO THE ENTIRE SCOPE OF PROVIDING A FINISHED FACILITY, READY AND USEABLE FOR ITS INTENDED PURPOSE. GC SHALL BE RESPONSIBLE TO VISIT THE SITE PRIOR TO SUBMISSION OF BID. ANY DISCREPENCIES FROM PLANS SHALL BE CONVEYED TO THE NEXTORE PROJECT MANAGER PRIOR TO BID SUBMISSION. SUBMISSION OF BID SHALL CONSTITUTE ACKNOWLEDGEMENT AND ACCEPTANCE OF EXISTING CONDITIONS. B. ALL MATERIALS AND/OR LABOR FOR THE PROJECT WHICH IS SHOWN ON THE DRAWINGS AND SPECIFICATIONS OR IS REASONABLY INFERABLE THEREIN AS BEING NECESSARY TO PRODUCE A FINISHED PROJECT, SHALL BE PROVIDED BY GENERAL CONTRACTOR, WHETHER OR NOT THE WORK IS EXPRESSLY COVERED IN THE DOCUMENTS. THIS APPLIES TO ALL WORK, WITH THE EXCEPTION OF THOSE ITEMS INDICATED N.I.C. ("NOT IN CONTRACT") OR BY OTHERS. THE DESIGN INTENT OF THE DRAWINGS SHALL ALWAYS BE THE GOAL. 2. DIMENSIONS: THE WORD 'HOLD' REFERS TO A CRITICAL DIMENSION AND MUST BE ADHERED TO. IF THESE DIMENSIONS CAN NOT BE MET, CALL THE NEXTORE P.M. FOR DIRECTION. C. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COORDINATION BETWEEN SUBCONTRACTORS, SUPPLIERS, VENDORS OR ANY OTHER PARTIES SUPPLYING GOODS OR SERVICES TO THE PROJECT. NO EXTRA COMPENSATION WILL BE GIVEN TO ANY PARTY WHO HAS BID FROM AN INCOMPLETE SET OF DOCUMENTS OR WITH INSUFFICIENT FAMILIARITY WITH THE PROJECT OR THE SPECIFIC REQUIREMENTS THEREOF. IN THE EVENT OF INCONSISTENCIES OR DISCREPANCIES BETWEEN THE DOCUMENTS, CODES, CRITERIA OR REQUIREMENTS, THE MOST STRINGENT SHALL APPLY. THE GENERAL CONTRACTOR SHALL NOTIFY THE NEXTORE PROJECT MANAGER IMMEDIATELY OF SUCH DISCREPANCIES OR INCONSISTENCIES. 3. ON-SITE COMMUNICATION: A. THE GC SHALL CONTACT THE NEXTORE P.M. TO RESOLVE ALL FIELD ISSUES. B. GC TO HAVE CELL PHONE WITH VOICEMAIL CAPABILITIES. C. GC TO HAVE LAPTOP ON SITE WITH WIFI CAPABILITIES. D. IT IS THE RESPONSIBILITY OF THE G.C. TO VERIFY BOTH EXISTING SITE CONDITIONS AND DIMENSIONS WITHIN 24 HOURS OF STARTING ANY PROJECT. THE G.C. SHALL NOTIFY THE CONSTRUCTION MANAGER IMMEDIATELY OF ANY DISCREPANCIES PRIOR TO INITIATING CONSTRUCTION. 4. CHANGE ORDERS: NO ADDITIONAL COSTS OR DESIGN CHANGES WILL BE ACCEPTED WITHOUT THE WRITTEN APPROVAL OF THE NEXTORE P.M. AND THE EXECUTION OF THE NEXTORE CHANGE ORDER PROCEDURE, PRIOR TO THE COMMENCEMENT OF SUCH WORK. CHANGE ORDER WORK COMPLETED WITHOUT SIGNED APPROVAL TO DO SAME, IS DONE SO AT THE GC'S RISK. E. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING A CURRENT SET OF CONSTRUCTION DRAWINGS ON SITE AT ALL TIMES DURING CONSTRUCTION. THE GENERAL CONTRACTOR SHALL INDICATE ON THESE PLANS ALL APPROVED CHANGES TO THE WORK. THIS SET OF DRAWINGS SHALL BE UPLOADED VIA EVOCO IN PDF FORMAT TO THE NEXTORE PROJECT MANAGER UPON COMPLETION OF THE PROJECT. THESE DRAWINGS SHALL BE MARKED UP TO REPRESENT A COMPLETE AND ACCURATE SET OF “AS-BUILT” DRAWINGS. ANY AND ALL CHANGES SHALL BE NOTED ON SAID PLANS. F. IF ANY ERRORS, DISCREPANCIES OR OMISSIONS APPEAR OR ARE EVIDENT ON ANY OF THE DOCUMENTS, THE GENERAL CONTRACTOR, SUBCONTRACTOR, VENDOR OR SUPPLIER SHALL IMMEDIATELY NOTIFY THE NEXTORE PROJECT MANAGER. G. 5. SUBCONTRACTOR COORDINATION: THE GC MUST BE PRESENT AT ALL TIMES FOR THE DURATION OF CONSTRUCTION. THE GC SHALL GIVE SUBCONTRACTORS APPROPRIATE NOTICE BEFORE REQUIRING THEM ON SITE, COORDINATE INSTALLATION DATES, AND COMMUNICATE SITE SPECIFIC DETAILS. THE GC SHALL COORDINATE THE INSTALLATION SCHEDULE AND DIVISION OF WORK WITH THE NEXTORE P.M. SUBCONTRACTORS SHOULD CONTACT THE GC FOR SCHEDULE CLARIFICATIONS. MILLWORK / CASEWORK: GC SHALL COORDINATE CRITICAL DIMENSIONS PRIOR TO WALL CONSTRUCTION AND HAVE THE AREA READY PRIOR TO FIXTURE DELIVERY. READY SHALL BE DEFINED AS FLOORING DOWN THRU-OUT THE RETAIL AND OPTOMETRIC DOCTOR (OD) RECEPTION, LIGHTING SOFFITS BUILT OUT, DRYWALLED, FINISHED, PAINTED AND LIGHTING FIXTURES INSTALLED, ALL WALLS IN THE RETAIL AND OD RECEPTION MUST BE FINISHED AND PAINTED, ALL ELECTRICAL AND MECHANICAL ROUGH-OUTS MUST BE COMPLETED, STORE MUST BE SECURED FROM THE OUTSIDE. ONCE THE PRE-CONSTRUCTION MILLWORK DROP / INSTALL DATE HAS BEEN ESTABLISHED, ANY CHANGES TO THE ESTABLISHED DATE MUST BE COMMUNICATED AT LEAST 7 DAYS PRIOR. NO MATERIAL SUBSTITUTIONS WILL BE ALLOWED UNLESS SUBMITTED IN WRITING AND APPROVED IN WRITING BY THE NEXTORE PROJECT MANAGER. H. THE GENERAL CONTRACTOR SHALL, ON OR BEFORE THE SOONER OF: WITHIN 10 WORKING DAYS OF CONTRACT AWARD OR THE START OF THE PROJECT, PROVIDE TO NEXTORE AND KEEP CURRENT, A LIST OF ALL SUBCONTRACTORS TO BE USED ON THE PROJECT. THE GENERAL CONTRACTOR SHALL ALSO PROVIDE A COPY OF THIS LIST TO THE NEXTORE PROJECT MANAGER AT CONSTRUCTION COMPLETION, AND A COPY IS TO BE INCLUDED IN THE CLOSEOUT PACKAGE FROM THE GENERAL CONTRACTOR. I. THE GENERAL CONTRACTOR SHALL INSPECT, VERIFY AND INVENTORY ALL SHIPMENTS OF NEXTORE SUPPLIED MATERIALS, INCLUDING THOSE TO AND FROM ANY OFF SITE WAREHOUSE FACILITIES. THIS INCLUDES VERIFYING PACKING LISTS AGAINST ORDER FORMS AND BILLS OF LADING, AND NOTING AND REPORTING ANY DAMAGES OR SHORTAGES TO THE NEXTORE PROJECT MANAGER. IF NOT DONE WITHIN 24 HOURS OF DELIVERY, THE GENERAL CONTRACTOR SHALL BEAR ANY AND ALL ASSOCIATED COSTS, INCLUDING EXPEDITED FREIGHT CHARGES, TO MEET THE CONSTRUCTION SCHEDULE. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FILING DAMAGE REPORTS AND MAINTAINING PACKING MATERIALS FOR RETURN SHIPMENT OF DAMAGED ITEMS. K. THE GENERAL CONTRACTOR SHALL DELIVER TO THE NEXTORE PROJECT MANAGER A COPY OF THE CERTIFICATE OF OCCUPANCY (C OF O), LIEN WAIVERS, WARRANTIES, GUARANTEES AND EQUIPMENT OPERATION MANUALS. THE ORIGINAL CERTIFICATE OF OCCUPANCY IS TO BE LEFT WITH THE STORE GENERAL MANAGER. REMODEL STORES: GC TO COORDINATE ALL TEMPORARY AND PERMANENT DATA AND PHONE CABLING DURING THE OPEN REMODEL. KEEPING STORE POS AND PHONE SYSTEMS ON LINE AND ACTIVATED AT ALL TIMES. COORDINATE WORK WITH TENANT LOW VOLTAGE VENDOR. 7. ELECTRICAL AND LIGHTING DELIVERIES GC SHALL BE RESPONSIBLE FOR THE COORDINATION OF DELIVERIES, FOR THE OFF-LOADING OF SAME, AND TO VERIFY / REPORT ANY DAMAGE AND FOR THE SAFE STORAGE OF ALL MATERIALS RECEIVED. THE GC SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. L. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEAN UP AND DISPOSAL OF ALL TRASH AND DEBRIS GENERATED BY ALL TRADES. GC. TO REMOVE/DISPOSE OF ALL BOXES/CRATES/TRASH OF TENANT SUPPLIED AND INSTALLED ITEMS, INCL. DISPLAY FIXTURES & HARDWARE. DAILY CLEAN REQUIRED. THESE CONSTRUCTION DOCUMENTS ARE NOT TO BE SCALED. ALL DIMENSIONS ARE TO FINISH FACE OF WALL, UNLESS OTHERWISE NOTED N. THESE DRAWINGS ARE NOT TO BE ALTERED IN ANY WAY WITHOUT THE WRITTEN AUTHORIZATION FROM NEXTORE OR NEXTORE'S ARCHITECT. O. THE GENERAL CONTRACTOR SHALL MAINTAIN EGRESS AT ALL TIMES DURING STORE OPERATION / CONSTRUCTION. P. THE GENERAL CONTRACTOR SHALL COORDINATE CONSTRUCTION TIMES AND NOISE REQUIREMENTS WITH LANDLORD PRIOR TO CONSTRUCTION START, NO EXTRA COSTS WILL BE ALLOWED TO ACCOMMODATE ANY RESTRICTIONS OR LIMITATIONS. 8. METER INSTALLATION (WATER / ELECTRIC / GAS): UTILITY ACCOUNT TRANSFER / SETUP (FOR CORPORATE NEW AND RELOCATION STORES ONLY): GC SHALL CONTACT THE NEXTORE RETAIL STORE MAINTENANCE HOTLINE (513)765-3500 UPON ARRIVAL AT THE SITE. GC WILL NOT BE RESPONSIBLE FOR ANY UTILITY COSTS DURING CONSTRUCTION. GC TO CONTACT NEXTORE TO CONVERT METERS TO NEXTORE NAME IMMEDIATELY UPON CONSTRUCTION START UP. GC TO PROVIDE THE FOLLOWING INFORMATION WHEN CALLING: A. STORE ADDRESS AND SPACE # B. UTILITY COMPANY (S) NAME AND PHONE # (I.E., GAS, ELECTRIC, WATER AND POSSIBLY SEWER) C. METER AND SOCKET # (IF USED) D. EXPECTED "PUNCH" DATE (TIMING FOR NEW INSTALLATION OR UTILITY ACCOUNT TRANSFER WILL BE EXECUTED ON/OR BEFORE THE "PUNCH" DATE). Q. UPON COMPLETION OF CONSTRUCTION, IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CLEAN ALL SURFACES / FIXTURES PER MANUFACTURER'S INSTRUCTIONS AND TO EMPLOY THE SERVICES OF A PROFESSIONAL CLEANING COMPANY TO ASSURE DELIVERY TO THE TENANT OF AN ABSOLUTELY CLEAN STORE. (2) CLEANINGS REQUIRED. (1) PRIOR TO PUNCH & (1) AT TURNOVER. THE FINAL CLEANING IS TO BE PERFORMED NO MORE THAN ONE DAY PRIOR TO THE TURN OVER. IF AN UNTIDY STORE IS TURNED OVER, NEXTORE RESERVES THE RIGHT, WITHOUT NOTICE TO THE GENERAL CONTRACTOR, TO EMPLOY PROFESSIONAL CLEANING SERVICES AND DEDUCT THE COST PLUS 15% FROM THE BALANCE OF THE GENERAL CONTRACTOR. R. THE GENERAL CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR ALL EQUIPMENT, FINISHES, MERCHANDISE, CARPET, ETC., INCLUDING THE WORK OF OTHERS, THROUGHOUT THE DURATION OF THE PROJECT. S. THE GENERAL CONTRACTOR SHALL COORDINATE ALL ACTIVITIES WITH THE LANDLORD PRIOR TO THE START OF CONSTRUCTION, AND COORDINATE WITH THE LANDLORD, ALL INTERRUPTION OF SERVICES. ANY SHUT DOWNS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR 9. TURNOVER PROCEDURE: A. THE GC SHALL CALL THE THE NEXTORE P.M. TO CONFIRM THE TURNOVER DATE NO LATER THAN 10 WORKING DAYS BEFORE TURNOVER. B. ALL CONSTRUCTION ITEMS, INCLUDING ITEMS ON THE INSTALLATION SCHEDULE ARE TO BE COMPLETED BEFORE TURNOVER DAY. C. THE GC AND NEXTORE P.M. TO CONDUCT THE PUNCH WALKTHROUGH, NOTING ALL DEFICIENCIES AND TIMING FOR RESOLUTION. D. A "SUBSTANTIAL COMPLETION" DOCUMENT WILL BE DISTRIBUTED TO THE GC. THE GC SHALL REMAIN ON SITE UNTIL ALL "PUNCH LIST" ITEMS ARE COMPLETE AND THE NEXTORE PM HAS SIGNED OFF CONFIRMING COMPLETION OF THE "PUNCH LIST". E. A COPY OF THE "CONFIRMED COMPLETION OF PUNCH LIST" WILL BE GIVEN TO THE NEXTORE P.M. T. THE GENERAL CONTRACTOR SHALL INSTALL A LANDLORD AND CODE COMPLIANT TEMPORARY BARRICADE AS REQUIRED BY THE LANDLORD OR NEXTORE PROJECT MANAGER, UNLESS THE PLANS SPECIFICALLY CALL OUT FOR THIS WORK TO BE BY OTHERS. U. GENERAL CONTRACTOR SHALL INSTALL A TEMPORARY ENTRANCE WITH DOORS, FRAMES AND LOCKS, UNLESS THE PLANS SPECIFICALLY CALL OUT FOR THIS WORK TO BE BY OTHERS. V. ALL CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CODES AND ORDINANCES, THE LANDLORD'S TENANT DESIGN CRITERIA, THE LANDLORD'S CONSTRUCTION RULES AND REGULATIONS, NEXTORE STANDARD SPECIFICATIONS, NEXTORE'S STANDARD CONSTRUCTION CRITERIA AND ACCEPTED BEST CONSTRUCTION PRACTICES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO FILE ANY NEEDED "NOTICE OF COMMENCEMENT" OR OTHER FILINGS RELATED TO THE PROJECT IN THE APPROPRIATE OFFICES AND SHALL BE RESPONSIBLE TO POST SUCH NOTICES AT THE JOB SITE. W. ALL WOOD CONSTRUCTION, INCLUDING BLOCKING, SHALL BE FIRE RESISTANT TREATED (FRT). ALL NEW FRAMING AT THE STOREFRONT AND / OR ABOVE THE CEILING SHALL BE NON-COMBUSTIBLE. X. THE GENERAL CONTRACTOR SHALL, PRIOR TO BEGINNING ANY WORK, COORDINATE WITH THE LANDLORD OR ANY AUTHORITY HAVING JURISDICTION, AND BEAR THE COSTS FOR, ALL EXPLORATIONS / X-RAYS REQUIRED FOR CUTTING/CORING OF THE SLAB OR EXCAVATING. Y. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WITH THE STRUCTURE AND SHELL BUILDING ELEMENTS. THE GENERAL CONTRACTOR SHALL IMMEDIATELY NOTIFY THE NEXTORE PROJECT MANAGER OF ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND THE BUILDING SHELL. Z. THE GENERAL CONTRACTOR SHALL PROVIDE ALL FIRE EXTINGUISHERS, CONCEALED BLOCKING AND SIGNAGE FOR SAME AS REQUIRED. QUANTITIES, SIZES AND LOCATIONS SHOWN IN THE DRAWINGS ARE ONLY SUGGESTED QUANTITIES, SIZES AND LOCATIONS, THE MOST STRINGENT REQUIREMENT OF ANY BODY HAVING JURISDICTION SHALL PREVAIL. AA. THE GENERAL CONTRACTOR SHALL DESIGN, INSTALL, LOCATE, RELOCATE, RECONFIGURE THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS AS REQUIRED BY THE INTENT OF THESE CONSTRUCTION DOCUMENTS OR ANY CODE OR BODY HAVING JURISDICTION OVER THE WORK. ALL FIRE SPRINKLER AND FIRE ALARM SYSTEM WORK SHALL BE 'DESIGN BUILD' BY THE GENERAL CONTRACTOR, UNLESS CALLED OUT TO BE PERFORMED SPECIFICALLY BY OTHERS IN THE DOCUMENTS (SEE FIRE SPRINKLER SYSTEM / FIRE ALARM SYSTEM NOTES. GC TO COORDINATE WITH LANDLORD REQUIRED VENDOR. AB. RESERVED AC. THE GENERAL CONTRACTOR SHALL, WITHOUT EXCEPTION, PROVIDE AND INSTALL ANY AND ALL DUST PROTECTION, REQUIRED DURING CONSTRUCTION. AD. GENERAL CONTRACTOR TO PROVIDE ALL FLOOR PREPARATION AS NEEDED TO ASSURE COMPLIANCE WITH FINISHED FLOORING MANUFACTURER SPECIFICATIONS. AE. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL CEILING WORK WITH THE MEP DRAWINGS. AF. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL LIGHTING WITH THE ELECTRICAL DRAWINGS / REFLECTED CEILING PLAN. 10. SETDOWN FOR NEW CORPORATE STORES: NEXTORE'S NEW STORE TEAM WILL DELIVER ALL REMAINING OWNER FURNISHED ITEMS TO THE STORE ON THE EVENING OF "TURNOVER" DAY. THE GC SHALL BE ON SITE ON THE DAY AFTER "TURNOVER", WITH ONE (1) PLUMBER AND ONE (1) ELECTRICIAN TO ASSIST THE SETDOWN TEAM TO RESOLVE ANY ISSUES. THE GC SHALL SUPPLY DUMPSTER FOR REMOVAL OF SETDOWN DEBRIS. 11. SOUND SYSTEM: A. THE GC SHALL BE RESPONSIBLE TO CONTACT SOUND VENDOR 4 WEEKS PRIOR TO THE SCHEDULED DATE TO ARRANGE FOR INSTALLATION. B. REMODELS AND RELOCATIONS: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL, STORAGE AND REINSTALLATION OF SYSTEM (INCLUDING CD PLAYERS AND SPEAKERS) AT NEXTORE STORES DURING DURATION OF CONSTRUCTION. 12. SECURITY ALARM TRANSFER/MODIFICATION A. ALARM TRANSFER / MODIFICATION - GC SHALL CONTACT THE SECURITY VENDOR DURING ANY POINT IN CONSTRUCTION THE GC DETERMINES THEY WILL NEED TO DISABLE OR RELOCATE ANY ALARM SYSTEM COMPONENTS. GC SHALL AWAIT INSTRUCTIONS FROM THE "NEXTORE SECURITY LIAISON" BEFORE TAKING ANY ACTION ON THE SECURITY SYSTEM. B. CAMERAS - GC SHALL CONTACT THE "NEXTORE LOSS PREVENTION MANAGER" TO COORDINATE THE REINSTALLATION OF SECURITY CAMERAS ON REMODEL OR RELOCATION STORES THAT ALREADY HAVE CAMERAS IN PLACE AND ARE BEING DISTURBED DURING CONSTRUCTION. 13. AIR BALANCE REPORTS G.C. RESPONSIBLE TO OBTAIN AIR BALANCING REPORT FROM A VENDOR INDEPENDENT FROM THE HVAC CONTRACTOR. AG. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL LIGHT FIXTURES SUPPORTS, INCLUDING ANY AND ALL SEISMIC REQUIREMENTS. AH. AJ. THE GENERAL CONTRACTOR SHALL RECEIVE, UNLOAD, AND PROVIDE SAFE STORAGE OF ALL NEXTORE / NEXTORE SUPPLIED AND / OR INSTALLED MATERIAL. TRASH REMOVAL OF ALL BOXES / CRATES CONTAINING NEXTORE / NEXTORE SUPPLIED AND / OR INSTALLED MATERIAL, INCLUDING BUT NOT LIMITED TO FLOORING, MILLWORK, LIGHTING, HARDWARE, ACCESSORIES, EQUIPMENT, ETC. SHALL BE BY THE GENERAL CONTRACTOR. AK. NOTICE OF INCIDENT: THE GENERAL CONTRACTOR SHALL, VIA ELECTRONIC MEDIUM AND NEXTORE STANDARD NOTIFICATION AND REPORTING FORMS, IMMEDIATELY NOTIFY THE NEXTORE PROJECT MANAGER OF ANY INCIDENT INVOLVING THE PROJECT WHICH RESULTS IN CONTACT WITH ANY FEDERAL, STATE OR LOCAL GOVERNMENT AGENCY OR AS CALLED OUT IN NEXTORE'S OR THE LANDLORDS RULES, REGULATIONS OR POLICIES. AL. WEEKLY PROGRESS PHOTOS, DAILY REPORTS, SAFETY INSPECTIONS, SCHEDULE UPDATES, CHANGE ORDER LOGS, RFI LOGS, AND TOOL BOX TOPICS SHALL BE SUBMITTED TO THE NEXTORE PROJECT MANAGER VIA EVOCO AS REQUIRED IN THE DOCUMENTS OR DIRECTED BY THE NEXTORE PROJECT MANAGER. AM. FOR THOSE PROJECTS THAT ARE “OPEN REMODELS”; STORES WILL REMAIN OPEN DURING REGULAR BUSINESS HOURS WHILE CONSTRUCTION IS IN PROGRESS. ALL DISTURBANCES TO SURROUNDING BUSINESSES AND AREAS MUST BE KEPT TO A MINIMUM. WORK DURING AN OPEN REMODEL IS TYPICALLY PERFORMED "AFTER NORMAL OPERATING HOURS." GC MUST COORDINATE WITH NEXTORE PROJECT MANAGER AND OR STORE OPERATIONS MANAGER PRIOR TO CONSTRUCTION START. THERE SHALL BE NO UP-CHARGE SUBMITTED, ALLOWED, OR CONSIDERED FOR ANY SUCH AFTER HOURS WORK. SAFETY: SAFETY OF ALL EMPLOYEES, ASSOCIATES AND CUSTOMERS SHALL BE THE NUMBER ONE PRIORITY FOR ALL CONTRACTORS ON ANY NEXTORE PROJECT. OSHA REQUIREMENTS SHALL BE INCORPORATED INTO THE SCOPE OF WORK EVEN THOUGH THEY MAY NOT BE LISTED SEPARATELY. CONTRACTOR SHALL MAINTAIN A COPY OF THEIR SITE SPECIFIC SAFETY PLAN ON SITE AT ALL TIMES REV0.1 VICINITY PLAN AREA OF PROJECT 1 By Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS PROJECT LOCATION STREET ADDRESS 5135 WEST ALABAMA CITY, STATE, ZIP HOUSTON, TX 77056 PHONE EMAIL: 513.262.0587 [email protected] MACY'S STORE INFO MACY'S #687 STORE CONTACTS DAVID BOESSENECKER STREET ADDRESS 5135 WEST ALABAMA CITY, STATE, ZIP HOUSTON, TX 77056 Architect of Record TELEPHONE: EMAIL: [email protected] JURISDICTION ASSOCIATES INC. NORTH CITY HOUSTON, TX DEPARTMENT CITY OF HOUSTON BUILDING DEPARTMENT STREET ADDRESS 1002 WASHINGTON AVE CITY, STATE, ZIP HOUSTON, TX PHONE 832-394-9000 2016-026A Seal MALL NAME GALLERIA AT HOUSTON STREET ADDRESS 5135 WEST ALABAMA CITY, STATE, ZIP HOUSTON, TX 77056 SPACE NUMBER FIRST FLOOR M (MERCANTILE) / NO CHANGE BUILDING: 2012 IBC, W/ HOUSTON AMENDMENTS MECHANICAL: 2012 UNIFORM MECHANICAL CODE W/ HOUSTON AMENDMENTS PLUMBING: 2012 UNIFORM PLUMBING CODE W/ HOUSTON AMENDMENTS FIRE: 2012 INTERNATIONAL FIRE CODE W/ HOUSTON AMENDMENTS ELECTRICAL 2014 NATIONAL ELECTRICAL CODE W/ HOUSTON AMENDMENTS ENERGY: 2009 IECC, W/ HOUSTON AMENDMENTS AREA C AREA B ACCESSIBILITY CODE: 2012 TEXAS ACCESSIBILITY STANDARDS & 2009 1CC A117.1 AREA A KEYPLAN HOUSTON CONSTRUCTION CODE AMMENDMENTS EGRESS: EXISTING MACY'S 1st FLOOR MERCANTILE 850 sf / 30 gross TOTAL 850 sf TOTAL = 29 2 EXITS FOR OCCUPANCY > 49 29 TOTAL AREA B MERCANTILE TOTAL 700 sf / 30 gross 700 sf TOTAL = 24 G001 GENERAL INFORMATION COVER SHEET - G002 RESPONSIBILITY SCHEDULE / ABBREVIATIONS - G003 SPECIFICATIONS 1 of 2 - G004 SPECIFICATIONS 2 of 2 - V100 MACY'S EXISTING 1ST FLOOR PLAN - AD100A DEMOLITION FLOOR & CEILING PLANS: AREA A - AD100B DEMOLITION FLOOR & CEILING PLANS: AREA B A100 FIXTURE FLOOR PLAN - A101 CONSTRUCTION FLOOR PLAN - A102 REFLECTED CEILING PLAN - A103 FINISH PLAN - A200 INTERIOR ELEVATIONS - A300 WALL TYPES - A400 MISCELLANEOUS SECTIONS & DETAILS - NAME: GLENN S. YEAKEL DATE: 07-01-16 REG NO: 20474 Engineer 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 MINIMUM NUMBER OF EXITS: TABLE 1015.1 AREA A & B OCCUPANT LOAD: TABLE 1004.1.1 ACTIVE REVISION NUMBER ARCHITECTURAL SPRINKLERED: FULLY FIRE ALARM: YES FIRE EXTINGUISHERS: YES OCCUPANCY: AREA A DRAWING TITLE CONSTRUCTION OF THE NEW LENSCRAFTERS DEPT. NO CHANGE OF EGRESS OF OR OCCUPANCY OF THE MACY'S STORE. REV 0.2 CONSTRUCTION TYPE: II-B ADDITIONAL CODES DRAWING INDEX JOB SITE ADDRESS CODE INFORMATION 281 Farmington Avenue Farmington, CT. 06032 NORTH REQ'TS MET; REF: SHEET V100 FOR EGRESS LOCATIONS MECHANICAL MINIUMUM PLUMBING FIXTURES MPE100 PLUMBING CODE; TABLE 403.1 24 TOTAL Seal MECHANICAL & PLUMBING OVERALL BUILDING PLANS - H100 HVAC SPECIFICATIONS AND DEMOLITION PLAN - H200 HVAC PLANS AND DETAILS - AREA A AREA A EGRESS WIDTH PER OCCUPANT: TABLE 1005.3.1 STAIRS: 0.20"/PERSON OTHER EGRESS: 0.15"/PERSON 29 OCCUPANTS x 0.15" = 4.35" 65' OPEN PERIMETER AT TENANT SPACE AREA B 24 OCCUPANTS x 0.15" = 3.6" EGRESS DOOR: 33" CLEAR WIDTH W/C LAVATORIES DRINKING FOUNTAINS SERVICE SINKS 1/500 1/750 1/1000 1 1 1 1 1 AREA B W/C LAVATORIES DRINKING FOUNTAINS SERVICE SINKS 1/500 1/750 1/1000 1 1 1 1 1 11 9 2 1 11 9 2 1 PROJECT DIRECTORY NEXTORE NEXTORE 6 CREAMERY BROOK EAST GRANBY, CT 06026 516.393.2484 4000 LUXOTTICA PLACE MASON, OH 45040 513.765.6000 PLUMBING P100 PLUMBING SPECIFICATIONS - P200 PLUMBING PLANS AND DETAILS NAME: DATE: ELECTRICAL MELISSA LUCE TEL 860.462-9349 FRIAR ASSOCIATES, INC 281 FARMINGTON AVENUE FARMINGTON, CT 06032 CONTACT: LINDA BLASZKA TEL: 860.678-1291 FAX: 860.677-5265 EMAIL: [email protected] MICAH WASHINGTON FRIAR ASSOCIATES II, LLC 281 FARMINGTON AVENUE FARMINGTON, CT 06032 CONTACT: ADAM PALMER TEL: 860.678-1291 FAX: 860.677-5265 EMAIL: [email protected] COMPANY STREET CITY, STATE, ZIP CONTACT TEL FAX EMAIL N/A RETAIL PERMIT GROUP 600 ANTON BLVD, 11TH FL COSTA MESA, CA 92626 CONTACT: DARREN BAYSA TEL: 714.975-9708 FAX: 714.975-9758 EMAIL: [email protected] REG NO: E100 ELECTRICAL SPECIFICATIONS, SYMBOLS & DEMO PLAN - E200 ELECTRICAL POWER & LOW VOLTAGE PLAN & DETAILS - E201 ELECTRICAL LIGHTING PLAN AND DETAILS - E300 ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULE - E400 CASEWORK DETAILS - THE SCOPE OF THIS BUILDOUT WILL INCLUDE: (ONLY IN AREA DETAILED ON SHEET V100) MINOR WALL & CEILING DEMOLITION, AS REQUIRED TO FACILITATE DESIGN CONSTRUCTION OF NEW NON LOAD BEARING WALLS NEW FLOORING FINISHES NEW CEILING NEW FURNITURE AND FIXTURES NEW OD OFFICE EQUIPMENT NEW SIGNAGE AND GRAPHICS UTILITY WORK AS REQUIRED TO ACCOMMODATE PROJECT SCOPE Date 07/07/16 CONST. COORDINATOR MANNY WEINSTEIN THIS PROJECT IS THE TENANT BUILDOUT OF AN EXISTING MERCANTILE SPACE IN AN EXISTING INTERIOR SHOPPING CENTER AND INCLUDES INTERIOR CONSTRUCTION. Mark MACY'S CORPORATE SERVICES LANDLORD SCOPE OF WORK THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING REQUIRED FIRE RATINGS AND FIRE PROOFING IN ALL INSTANCES. AI. ALL PENETRATIONS OF DEMISING WALLS, ROOF AND FLOOR SHALL BE FIRE SAFE / PROOF PER CODES / LANDLORD REQUIREMENTS. THE MOST STRINGENT REQUIREMENT SHALL PREVAIL. MACY'S 1st FLR KEY PLAN 6. DATA-POS / PHONES: NEW T.I. & RELO STORES: BACKBOARD TO BE INSTALLED WITHIN 7 CALENDAR DAYS OF THE CONSTRUCTION START DATE. ACCESS TO BACKBOARD SHALL BE AFFORDED TO ALL TENANT VENDORS. TELEPHONE, ELECTRIC AND DATA CABLING INSTALLED ONE WEEK BEFORE "PUNCH" FOR HARDWARE INSTALLATION AND TESTING. CONTACT NEXTORE P.M. IF NEEDED. J. THE GENERAL CONTRACTOR SHALL KEEP ALL HANDBOOKS, MANUALS, WARRANTY DOCUMENTS AND MISCELLANEOUS PAPERWORK, INCLUDING ALL PACKING SLIPS AND BILLS OF LADING IN A MARKED BINDER. THIS BINDER IS TO BE TURNED OVER TO THE STORE GENERAL MANAGER AT PROJECT COMPLETION. COPIES OF THOSE ITEMS AND DOCUMENTS REQUIRED FOR INCLUSION IN THE CLOSEOUT PACKAGE SHALL BE MADE BY THE GENERAL CONTRACTOR AS NEEDED FOR THIS SUBMISSION. M. BUILDING DATA LANDLORD'S ADDRESS Revisions: FR I A R GENERAL NOTES Macy's Store Number: (687) Nextore project Number ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title DEFERRED SUBMITTALS THE AWARDED GENERAL CONTRACTOR SHALL ENGAGE THE REQUIRED MACY'S VENDORS AND SUBMIT FOR SEPARATE PERMIT FIRE ALARM AND SPRINKLER WORK. 73052 Date GENERAL INFORMATION COVER SHEET 07-01-16 Drawn By LLB Checked By ANP Sheet G001 T= TENANT GC= GENERAL CONTRACTOR LL= LANDLORD MW= MILLWORKER N/A= NOT APPLICABLE NOTE: THE GENERAL CONTRACTOR SHALL VERIFY ALL ITEMS ON THIS SCHEDULE FOR ACCURACY PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO LUXOTTICA PROJECT MANAGER IMMEDIATELY. SUPL RCV. INSTL EX'G BUILDING PERMIT PROFESSIONAL CLEAN-UP, FINAL CLEANING DEMOLITION TEMPORARY FACILITIES / UTILITIES OTHER PERMITS, FEES, INSURANCE TEMPORARY BARRICADES (W/ LUX BRAND SPECIFIC LOGO) T GC GC GC GC GC GC GC GC GC GC GC GC TRASH REMOVAL AND DUMPSTERS GC GC CUTTING AND PATCHING RELOCATION OF EXISTING MACY'S FIXTURES GC GC GC ASSET PROTECTION COORDINATION INSURANCE GC GC DIVISION 03000 - CONCRETE SUPL DIVISION 05000 - MISC. METALS SUPL IF OVERNIGHTS REQUIRED, GC SHALL PAY AP VENDOR & COORDINATE OVERNIGHT POWER W OPS MANAGER. GC TO ADD MACYS AS AN ADDITIONALLY INSURED PARTY ON CERTIFICATE OF LIABILITY INSURANCE. CERTIFICATES NEED TO BE SENT TO THE NEXTORE PROJECT MANAGER. NEXTORE PROJECT MANAGER TO FORWARD TO THE MACY'S PROJECT MANAGER. RCV. INSTL EX'G RCV. INSTL EX'G RCV. INSTL EX'G GC GC GC GC DIVISION 07000 - THERMAL & MOISTURE PROTECTION SUPL RCV. INSTL EX'G SEALANTS, INSULATION, FIRE CAULKING & BLOCKING SPRAYED FIRE RESISTIVE MATERIALS THROUGH PENETRATIONS FIRE STOP SYSTEM BATT INSULATION AND/OR SOUND ATTENUATION WATERPROOF MEMBRANE GC GC GC GC GC GC GC GC GC GC DIVISION 08000 DOORS & WINDOWS SUPL RCV. INSTL EX'G RELO GC GC GC GC T GC GC GC GC GC GC GC GC GC T GC GC GC GC GC GC GC T GC GC T T T T T T T GC GC GC GC GC T T T T T T GC GC GC T GC GC T T T T T T T RELO +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 REMARKS ALL MILLWORK LIGHTING IS PLUG & PLAY Macy's Store Number: (687) GC TO REFER TO ELECTRICAL RISER DIAGRAM WIRING AND FINAL CONNECTIONS BY GC PROVIDE NEW DEVICES AND/OR MODIFY AS REQUIRED. UTILIZE LANDLORD REQUIRED FIRE ALARM VENDOR. GC TO RELOCATE WHEN APPLICABLE / MATCH EXIST. WIRE AND EXTEND WIRING TO BE PLENUM RATED G.C. TO COORDINATE WIRING TO BE PLENUM RATED TENANT'S LOW VOLTAGE VENDOR PERFORMS DATA TERMINATIONS GC SHALL PROVIDE ALTERNATE PRICE - SEE ELECTRICAL SHEETS. WIRING TO BE PLENUM RATED Revisions: Mark Date 1 GC SHALL PROVIDE ALTERNATE PRICE - SEE ELECTRICAL SHEETS. By 07/07/16 Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS GC SHALL PROVIDE ALTERNATE PRICE - SEE ELECTRICAL SHEETS. WIRING TO BE PLENUM RATED REMARKS Architect of Record FIRE RETARDENT WOOD AND METAL PER AUTHORITY JURISDICTION / LL DURABLE PROTECTION REQUIRED. PROVIDE WALK-OFF MAT AT BOTH SIDE OF ENTRY POINT(S) OF CONSTRUCTION AREA RELO GC GC GC GC GC REMARKS SEE SPECIFICATIONS IF REQUIRED BY LL ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 EXTENTS OF WATERPROOF MEMBRANE SHALL BE VERIFIED W LL BY THE GC REV 0.7 SUPL RCV. INSTL EX'G T T T T T GC GC T T GC GC GC GC GC GC T SUPL RCV. INSTL EX'G T T T T T T GC T T T DIVISION 15000 - MECHANICAL SUPL VINYL BASE @ ROUND COLUMNS CARPET TILE C-63 WILL BE NEXTORE FURNISHED, GC INSTALLED, UNLESS SPECIFIED ON THE DRAWINGS. ANY SPECS OTHER THAN C-63 WILL BE GC SUPPLIED AND INSTALLED (INCLUDING BORDERS OR MATCHING EXISTING MACY'S CARPET SPECS). GC MUST INSTALL FLOOR PER FLOORING MFG SPECS. REFER TO FINISH SCHEDULE SHEET A103. ACCESS PANELS ROOF WORK HVAC DISTRIBUTION, DUCTWORK, DIFFUSERS GC GC GC GC GC GC GC GC GC PLUMBING FIXTURES GC/T GC GC OD SINKS FLOOR DRAINS / PIPING / SUPPORTS WATER AND SEWER CONNECTION SPRINKLER SYSTEM MODIFICATIONS SANITARY PUMP (ALL COMPONENTS) SANITARY BOOSTER INSTA-HOT WATER HEATERS MW GC GC GC GC GC GC GC GC GC GC GC GC GC PAINTED P104 X REMARKS G.C. TO COORDINATE SIGN INSTALLATION SEE FIXTURE PLAN FOR MORE INFORMATION SEE FIXTURE PLAN FOR MORE INFORMATION SEE FIXTURE PLAN FOR MORE INFORMATION SEE FIXTURE PLAN FOR MORE INFORMATION NOTE: y=54 in. (1370 mm) minimum if door has both a latch and a closer NOTE: y=48 in. (1220 mm) minimum if door has both a latch and a closer DATE: 07-01-16 REG NO: 20474 Clear Floor Space 48 min. 1220 6 max. Toe Clearance 150 Knee Clearance 8 min 205 Latch-side Approaches - Swinging Doors SUGGESTED LOCATION ON PLAN - VERIFY LOCAL REQUIREMENTS 19 max. 485 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 17 min. Lav. Depth 430 Lavatory Clearances REMARKS RECEIVED & OFFLOADED BY G.C. / UNCRATED & INSTALLED BY TENANT RECEIVED & OFFLOADED BY G.C. / UNCRATED & INSTALLED BY TENANT G.C. TO COORDINATE G.C. TO COORDINATE NOTE: LAVATORY HAS LEVER OR EQUAL FAUCET HARDWARE AND THE PIPES UNDER THE SINK ARE INSULATED OR OTHERWISE COVERED. Seal Counter 30 min. 760 30 min. 760 FRAMES ORDERED BY FIELD TEAM INSTALLED BY G.C. RELO GLENN S. YEAKEL Engineer 17 min. 430 760 24 min. 610 COMPLETE FINISH BY MW 24 min. 610 PUSH SIDE 30 min. X PULL SIDE RELO NAME: NOTE: All doors in alcoves shall comply with clearances for front approaches. GC TO COORD. WITH LANDLORD. PROVIDE SAMPLE AND RECEIVE APPROVAL. GC MUST INSTALL FLOOR PER FLOORING MFG SPECS RELO NOTE: y=48 in. (1220 mm) minimum if door has both a latch and a closer Hinge-side Approaches - Swinging Doors Front Approaches - Swinging Doors Suggested Supply Lines Base Height Cabinet Heights GC GC GC GC GC GC GC Y 42 min. 1065 NOTE: x=36 in. (915 mm) minimum if y = 60 in. (1525 mm) : x =42 in. (1065 mm) minimum if y = 54 in. NOTE: x=12 in. (305 mm) if the door has both a closer and a latch GC MUST INSTALL FLOOR PER FLOORING MFG SPECS. MW MW MW MW T T T T T T GC GC GC GC GC GC GC GC GC GC RCV. INSTL EX'G Y SEE PLANS FOR SCOPE OF WORK SEE PLANS FOR SCOPE OF WORK. PER USG AETHETIC ASSEMBLIES, ALL WALLS (INCLUDING EXISTING TO REMAIN), SHALL RECEIVE "LEVEL 4" FINISH, & CEIL "LEVEL 5" T GC T T GC GC GC T MILLWORK (RETAIL) MILLWORK (O.D.) OD EQUIPMENT POS EQUIPMENT LENS PROCESS EQUIPMENT MERCHANDISE PROPS SHELVES & STANDARDS (OD/EMPLOYEE AREA) FURNITURE (CHAIRS, BENCHES, TABLES, ETC.) STAPLES PURCHASED ITEMS DOCTOR'S CERTIFICATES / LICENSES X 34 T GC GC GC GC GC GC GC GC GC GC GC T GC GC T GC GC MW MW MW GC GC GC GC GC GC GC GC GC 22 min 27 min. 685 9 min. 230 PORCELAIN FLOOR TILE GROUT AND THINSET FOR TILE & ACCESSORIES FLOORING TO MATCH EXISTING MACY'S FLOORING FLOORING TRANSITION STRIPS WALLCOVERING WALLTILE CUSTOM WOOD MILLWORK WD201 3/4" X 3/4" WOOD TRIM WOOD TRIM (OPEN DOOR SURROUND) WOOD BASEBOARD WB101 GC GC GC GC GC GC GC REMARKS PUSH SIDE PULL SIDE 40 max. 34 max. GC GC GC GC GC GC GC RELO 18 min 455 PUSH SIDE 48 min. 1220 GC GC GC GC GC GC X PULL SIDE 1065 RCV. INSTL EX'G 2016-026A Seal UNLESS NOTED OTHERWISE. (SEE DOOR SCHEDULE SHEET A101) IF EGRESS DOOR REQUIRED GC GC GC GC GC GC SUPL REMARKS Y 42 min GC GC GC GC GC GC RELO 34 GC GC T GC MW GC T/GC DIVISION 12000 - FURNISHINGS REMARKS RCV. INSTL EX'G GC GC GC GC T T T GC T GC +1 (513) 765-6000 p N/A GC GC GC GC NEW DEMISING PARTITIONS (STUDS & INSTALLATION) NEW DEMISING PARTITIONS (GYPSUM WALLBOARD) DRYWALL CEILING, WALLS, ENCLOSURES & REQ'D FRAMING ACOUSTICAL CEILING 2'x2' TILES & GRID PAINTING, FINISHING, VARNISH, SEALER, ETC. FLOOR TRANSITIONS/VINYL TILE / VINYL WALL BASE CARPETING RETAIL WALL SIGNAGE GRAPHIC HOLDER GRAPHICS GRAPHICS VINYLS AND BARRICADE GRAPHICS ACCESSIBILITY SIGNAGE STORAGE AREA SHELVES & SURFACE MTD. STANDARDS FIRE EXTINGUISHERS GLAZING FILM - GRAPHIC RELO REMARKS SUPL p 6 Creamery Brook, East Granby, CT 06026 FR I A R RCV. INSTL EX'G GC GC GC GC DIVISION 10000 - SPECIALTIES RELO CONNECTION AND WIRING @ MILLWORK THROUGHOUT ELECTRICAL SERVICE CONDUIT ONLY ELECTRICAL PANELS / TRANSFORMERS ELECTRICAL WIRING, CIRCUITING, RECEPTACLES, SWITCHES RECEPTACLES IN MILLWORK EMERGENCY LIGHTING EXIT SIGNS FIRE ALARM SYSTEM NEW LIGHT FIXTURES & LAMPS REPLACEMENT OR MATCHING EXISTING LIGHT FIXTURES & LAMPS SOUND SYSTEM SPEAKERS TELEPHONE CONDUIT TO SPACE TELEPHONE WIRING TO SPACE TENANT TELEPHONE EQUIPMENT TELEPHONE WIRING CONDUITS - DATA, COMMUNICATION, ALARMS, PHONES POS AND DATA WIRING WIRELESS EQUIPMENT JACK TERMINATION & FACEPLATE - DATA MACY'S BACKBOARD TERMINATION - DATA JACK TERMINATION & FACEPLATE - PHONE MACY'S BACKBOARD TERMINATION - PHONE SECURITY - FACILITY (HARDWARE & WIRING) 4000 Luxottica Place, Mason, OH 45040 a GC GC GC SUPL DIVISION 09000 - FINISHES REMARKS G.C. TO FIELD VERIFY EXIST. COND. TO DETERMINE EXTENTS OF SCOPE. GC TO REPORT TO PROJECT MANAGER. COORD. W/ LANDLORD & AFFECTED TENANTS. VERIFY W MACY'S OPERATIONS PRIOR TO ANY CORING OR TRENCHING. GC GC GC BLOCKING (INCL. FOR FIXTURES, SHELVES, SIGNS ROUGH CARPENTRY, FIRE RETARDANT LUMBER & PLYWD FLOOR PROTECTION (IF REQUIRED) FINISH CARPENTRY NEW DOORS, FRAMES, HARDWARE PANIC / SECURITY ALARM INTERIOR DOOR LOCK CORES AND KEYS ACCESS DOORS AND FRAMES MILLWORK MIRRORS WALL MOUNTED/FRAMED MIRRORS RELO DIVISION 16000 - ELECTRICAL 48 max. 1220 DIVISION 06000 - WOOD & PLASTICS LL GC TO VERIFY UPON ARRIVAL ON JOB SITE THAT THE SITE HAS BEEN CLEARED OF ALL MAC'Y FIXTURES IN ORDER TO PERMORM AREA CONSTRUCTION. NOTIFY NEXTORE PROJECT MANAGER OF ANY QUESTIONABLE ITEMS EXISTING. GC GC GC GC GC GC SUPL BASE BUILDING STRUCTURAL STEEL STRUCTURAL STEEL AS REQUIRED FOR TENANT BUILD-OUT METAL FABRICATIONS EXPANSION JOINTS INCLUDING ALL LOCAL PEST CONTROL REQUIREMENTS, PERMITS, VERIFY REQUIREMENTS COORDINATE WITH LANDLORD. LOGO SUPPLIED BY TENANT, INSTALLED BY GC VERIFY TOWN AND LANDLORD REQUIREMENTS. GC. TO REMOVE/DISPOSE OF ALL BOXES/CRATES/TRASH OF TENANT SUPPLIED AND INSTALLED ITEMS, INCL. DISPLAY FIXTURES & HARDWARE. DAILY CLEAN REQUIRED. LL DIVISION 04000 - MASONRY REMARKS GC SHALL AMEND / PICK UP PERMIT & PAY ADD'TL FEES; FEES BILLABLE TO NEXTORE AT NET COST; VIA CHANGE ORDER #1 (2) CLEANINGS REQUIRED. (1) PRIOR TO PUNCH & (1) AT TURNOVER FIELD VERIFY EXISTING CONDITIONS AND SEE PLANS FOR SCOPE IF REQUIRED 60 min. 1525 CONCRETE SLAB (NEW OR PATCH FILL) CUTTING OF EXISTING SLAB-TRENCHING OR CORE DRILLING RELO Y 48 min. 1220 DIVISION 01000 - GENERAL T= TENANT GC= GENERAL CONTRACTOR LL= LANDLORD MW= MILLWORKER N/A= NOT APPLICABLE a REMARKS NAME: COORDINATE WITH TRADES FOR SIZE AND LOCATION. GC TO COORD. W/ LANDLORD WHEN REQUIRED DATE: SEE PLUMBING SPEC. FOR CLARIFICATION OF PLUMBING FIXTURES SUPPLIED BY TENANT AND/OR G.C. PROVIDED BY MILLWORKER GC SEE PLUMBING DRAWINGS FOR SCOPE OF WORK GC BY L.L. DESIGNATED CONTRACTOR AT G.C. EXPENSE. GC RESP. FOR MODIFICATIONS, DRAWINGS, AND APPROVALS. GC SHALL PURCHASE PUMP FROM NEXTORE'S REQUIRED VENDOR. SEE PLUMBING SHEETS FOR CONTACT INFORMATION. 1. THIS PROJECT WILL COMPLY WITH ALL IAC 400.310 REQUIREMENTS UNDER IAC 400.320(n) - TENANT FINISHING WORK AND IAC 400.320(h) - BUSINESS AND MERCANTILE. 2. THIS PROJECT WILL COMPLY WITH ALL FEDERAL REQUIREMENTS UNDER ADAAG 4.1.3 - NEW CONSTRUCTION AND ADAAG 140 - BUSINESS AND MERCANTILE. 3. ALL DOORS LEADING TO REQUIRED ACCESSIBLE ROOMS AND SPACES SHALL BE A MIN. OF 3'-0" WIDE, HAVE LEVER OPERATED HARDWARE ( OR EQUAL), HAVE A MIN. OPENING FORCES OF 5 LBF, AND FULLY COMPLY WITH IAC 400.310 (j) 4. ALL NEW OR ALTERED ENVIRONMENTAL CONTROL AND OPERATING MECHANISMS WILL COMPLY WITH IAC 400.310(r) (FRONT REACH BETWEEN 15" ANF 48" A.F.F.) 5. ANY NEW EMERGENCY WARNING ALARMS, WHERE PROVIDED, SHALL BE BOTH AUDIBLE AND VISUAL AND COMPLY WITH IAC 400.810(s). THE VISUAL ALARMS WILL BE FLASHING TYPE WHERE THE FLASHING IS SYNCHRONIZED AND IN COMPLIANCE FOR INTENSITY AND FREQUENCY. ADA ADJ. A.F.F. CLG. C.J. COL. CONC. CONT. DIM. DWG. EA ELEC. EQ. EQUIP. EXT'G. F.E. FIN. FLR. G.C. GWB H.M. HT. HVAC INT. LAM. AMERICANS WITH DISIBILITIES ACT ADJACENT ABOVE FINISHED FLOOR CEILING CONTROL JOINT COLUMN CONCRETE CONTINUOUS DIMENSION DRAWING EACH ELECTRIC EQUAL EQUIPMENT EXISTING FIRE EXTINGUISHER FINISH FLOOR GENERAL CONTRACTOR GYPSUM WALLBOARD HOLLOW METAL HEIGHT HEATING/VENT./AIR CONDITIONING INTERIOR LAMINATE LOC. MEP MECH. MTL. MISC. N.I.C. N.T.S. NO. O.C. PL. RM. R.O. SHLV SIM. STL STRL. TME. T.O.W. TYP. U.L. U.N.O. VERT W/ WD LOCATION MECHANICAL ELECTRICAL PLUMBING MECHANICAL METAL MISCELLANEOUS NOT IN CONTRACT NOT TO SCALE NUMBER ON CENTER PLASTIC ROOM ROUGH OPENING SHELVES SIMILAR STEEL STRUCTURAL TO MATCH EXISTING TOP OF WALL TYPICAL UNDERWRITERS LABORITORIES UNLESS NOTED OTHERWISE VERTICAL WITH WOOD REG NO: Nextore project Number 73052 ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title Date RESPONSIBILITY SCHEDULE/ ABBREVIATIONS 07-01-16 Drawn By LLB Checked By ANP Sheet G002 PART 1 - GENERAL A. DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE COMPLIMENTARY. SPECIFIC INFORMATION MAY BE FOUND IN EITHER OR BOTH. B. BIDDING CONTRACTORS SHALL INCLUDE ALL LABOR, MATERIALS, SCAFFOLDING, CRANES, EQUIPMENT FASTENERS ETC. NECESSARY FOR COMPLETION AND FINAL COMPLETE TURNOVER OF AN OPERATIONAL RETAIL FACILITY. C. D. E. F. G. THE TENANT HAS INDICATED AN INTENTION TO USE AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT A-107 "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" AS PART OF THE CONTRACT DOCUMENTS FOR THIS WORK. ALL PERSONS INTENDING TO PROVIDE GOODS OR SERVICES IN CONNECTION w/THE WORK ARE ADVISED TO READ AND UNDERSTAND THE APPLICABLE ADA DOCUMENTS PRIOR TO PROCEEDING. THE TENANT HAS AWARDED SEPARATE CONTRACTS FOR SOME CONSTRUCTION WORK THAT WILL BE CONDUCTED SIMULTANEOUSLY WITH WORK UNDER THIS CONTRACT. GENERAL CONTRACTOR MUST COOPERATE WITH ALL OTHER CONTRACTORS SO THAT WORK UNDER THOSE CONTRACTS MAY BE CARRIED OUT SMOOTHLY, WITHOUT INTERFERING WITH, OR DELAYING WORK UNDER THIS CONTRACT. PRIOR TO START OF CONSTRUCTION, GENERAL CONTRACTOR SHALL ARRANGE A MEETING WITH LANDLORD'S CONSTRUCTION REPRESENTATIVE TO REVIEW AND ESTABLISH ALL LANDLORD REQUIREMENTS. THIS INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING: ALL CONSTRUCTION, SCHEDULES, WORKMAN PARKING, DELIVERY AND STORAGE OF MATERIALS, SAFETY PROTECTION, TRASH REMOVAL, SECURITY, AND DOCUMENTS REQUIRED FOR FINAL LANDLORD SIGN-OFFS. GENERAL CONTRACTOR IS TO NOTIFY TENANT'S CONSTRUCTION MANAGER IMMEDIATELY OF ANY ITEM THAT MAY AFFECT THE DESIGN INTENT OF THE DRAWINGS, OR RESULT. ANY ITEMS DIRECTED BY LANDLORD, INSPECTORS, OR ANY OTHER AUTHORITY THAT AFFECTS THE DESIGN INTENT OF THE DRAWINGS, OR RESULTS IN ADDITIONAL COSTS OR SCHEDULE DELAYS SHOULD NOT BE PERFORMED UNTIL RECEIPT OF APPROVAL BY TENANT'S CONSTRUCTION MANAGER. ALL CHANGES MUST IMMEDIATELY BE SUBMITTED IN WRITING TO TENANT'S CONSTRUCTION MANAGER FOR REVIEW. SUBMISSION SHALL INCLUDE A GENERAL DESCRIPTION OF THE WORK REQUESTED, SIGNED BY THE REQUESTING AUTHORITY. IN ADDITION, SUBMISSION MUST INCLUDE A COST BREAKDOWN AND THE IMPACT TO THE CONSTRUCTION SCHEDULE. 01005 CONTRACTORS USE OF THE PREMISES. PART 1 - GENERAL A. THE GENERAL CONTRACTOR AND ALL CONTRACTORS BIDDING ON THIS PROJECT SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ACTUAL JOB CONDITIONS AND TO CHECK FOR ANY INTERFERENCE BETWEEN THEIR WORK AND THAT OF OTHER TRADES AND/OR APPARENT VIOLATIONS OF LOCAL, STATE, OR FEDERAL CODES, LAWS, ORDINANCES, AND REGULATIONS BEFORE ENTERING INTO A CONTRACT WITH EITHER THE GENERAL CONTRACTOR AND/OR TENANT. 1. ALL ITEMS SHALL BE INCLUDED IN THE BASE BID TO ACHIEVE THE FINAL PRODUCT INDICATED IN DRAWINGS. THIS INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING: CONCRETE FLOOR PREP, FLOOR SLAB X-RAYING, DEMISING WALL GYPSUM BOARD EXTENT AND CONDITION, REQUIRED FIRE PROOFING, ELECTRICAL PANELS, ELECTRICAL, WATER, SEWER, VENTS AND TELEPHONE CONDUITS, ANY LANDLORD REQUIRED FIRE PROTECTION SYSTEM OR TIE-INS TO BLDG. MANAGEMENT SYSTEMS, FIRE EXTINGUISHERS, AND STRUCTURAL REQUIREMENTS FOR TENANT'S EQUIPMENT. 2. GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AND TENANT IN WRITING BEFORE ENTERING INTO A CONTRACT WITH THE TENANT IF ANY INTERFERENCE OR VIOLATIONS APPEAR AND DEPARTURE FROM THE DESIGN INTENT OF THE DOCUMENTS IS REQUIRED. 3. FAILURE TO PROVIDE ARCHITECT AND TENANT'S CONSTRUCTION MANAGER WITH THE AFOREMENTIONED NOTIFICATION SHALL RESULT IN THE GENERAL CONTRACTOR BEING HELD RESPONSIBLE TO COMPLETE ALL WORK REQUIRED TO MEET THE DESIGN INTENT OF THE CONTRACT DOCUMENTS AT HIS/HER OWN COSTS WITH NO ADDITIONAL EXPENSES (EXTRAS) BEING INCURRED BY THE TENANT. EXTRAS WILL NOT BE ALLOWED FOR JOB SITE CONDITIONS THAT WERE READILY VISIBLE OR DETERMINED. 4. ALL SUB TRADES SHALL COORDINATE THEIR WORK WITH THE WORK OF OTHERS OR WITH EXISTING CONDITIONS OCCURRING ABOVE OR BELOW THE LEASED PREMISES AND SHALL MAKE CHANGES FROM TIME TO TIME AS REQUESTED TO ACCOMMODATE SUCH WORK OR CONDITIONS AT NO CHARGE TO TENANT. 5. CONTRACTORS SIGNS OR SIGNS OF ANY KIND MAY NOT BE DISPLAYED ON BARRICADES 6. THE G.C. SHALL BUILD ON SITE A TEMPORARY LOCKABLE STORAGE AREA. G.C. SHALL ACCEPT ALL TENANT SUPPLIED ITEMS AND STORE THEM SAFELY IN SUCH SPACE. B. 01400 QUALITY/GUARANTEE B. PART 1 - GENERAL C. VERIFY GRADIENT AND ELEVATIONS OF BASE ARE CORRECT. THICKNESS AND REINFORCING AS SHOWN ON DRAWINGS. D. IMMEDIATELY AFTER PLACEMENT, PROTECT PAVEMENT FROM MECHANICAL INJURY. 2. 16 GAUGE AND HEAVIER COMPONENTS: FABRICATE COMPONENTS OF STRUCTURAL QUALITY STEEL SHEET, ASTM A446 FOR GALVANIZED FINISH WITH A MINIMUM YIELD POINT OF 50,000 PSI. E. DEPOSIT CONCRETE WITHIN ANY ONE SECTION CONTINUOUSLY SO THAT NO CONCRETE WILL BE PLACED ON OLDER CONCRETE WHICH HAS SET SUFFICIENTLY TO RESULT IN SEAMS AND PLANES OF WEAKNESS WITHIN SECTION. 3. METAL STUDS: AISI "C" TYPE STRUCTURAL STUDS; SIZES, GAUGES AND SPACINGS SHOWN OR REQUIRED IF NOT SHOWN; WITH 1-5/8" (41MM) MINIMUM FLANGE WIDTH, 1/2" (13MM) MINIMUM RETURNS AND PRE-PUNCHED HOLES FOR UTILITY INSTALLATION. PLACE SLABS FOR FULL THICKNESS IN ONE OPERATION, WITHOUT CHANGES IN PROPERTIES; SCREED TO PROPER ELEVATION; FLOAT AND LIGHTLY TROWEL. UNLESS OTHERWISE SPECIFIED, WHEN CONCRETE HAS SET SUFFICIENTLY TO RING UNDER TROWEL, GIVE SLAB SECOND TROWELING TO PRODUCE SMOOTH, DENSE SURFACE. DUSTING OF SURFACES WITH CEMENT IS PROHIBITED. % OPTIMUM DENSITY. PROVIDE MIN. 6" COMPACTED a. 18-22 GAUGE (0.05" / 1.2MM - 0.03" / 0.8MM): ASTM A446/A446M GRADE A; MINIMUM YIELD STRESS OF 33 KSI (228 MPA). A. B. A. A. A. A. B. C. 03732 CONCRETE REPAIR D. C. FLOOR LEVELER CONCRETE TO BE INSTALLED AT LOW AREAS, HOLES AND DEPRESSIONS. PATCH CRACKS AND BROKEN CONCRETE WITH FLOOR PATCH TROWELED SMOOTH IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND LANDLORD SPECIFICATIONS. UNDERLAYMENT COMPOUND TO BE FREE FLOWING, SELF-LEVELING, PUMPABLE, AND CEMENT-BASED FOR APPLICATIONS FROM ONE INCH THICK TO FEATHERED EDGES. A. B. ALL PROJECT COORDINATION SHALL BE THROUGH TENANT'S CONSTRUCTION MANAGER AS LISTED ON TITLE SHEET. COMPLY WITH CONSTRUCTION MANAGER'S PROCEDURES FOR INTRA-PROJECT COMMUNICATIONS; SUBMITTALS, REPORTS AND RECORDS, SCHEDULES, COORDINATION DRAWINGS, RECOMMENDATIONS; AND RESOLUTION OF AMBIGUITIES AND CONFLICTS, INCLUDING REQUESTS FOR SUBSTITUTIONS AND CHANGE ORDERS. A. B. PAYMENT SCHEDULE FOR PROJECT WILL BE ON A MONTHLY SUBMITTAL OF AIA DOCUMENT #G702 AND #G703 "APPLICATION AND CERTIFICATE FOR PAYMENT" UNLESS OTHERWISE REQUESTED BY TENANT. C. CONTRACT SHALL BE AIA DOCUMENT #A107 "STANDARD FORM OF AGREEMENT BETWEEN OWNER AND CONTRACTOR". 1) CONCRETE REPAIR 3. DEMOLITION INCLUDES REMOVAL OF THE EXISTING INTERIORS, IF REQUIRED, BUT NOT LIMITED TO INTERIOR PARTITIONS, CABINETS, SUSPENDED CEILING TILE, ELECTRICAL, MECHANICAL, ETC., AS REQUIRED, AS SHOWN OR AS DIRECTED. 4. ALL ITEMS INDICATED OR REQUIRED TO BE DEMOLISHED OR REMOVED TO BE LEGALLY DISPOSED OF IN COORDINATION AND COMPLIANCE WITH ALL LANDLORD PROCEDURES AND REGULATIONS. 5. ALL ITEMS INDICATED TO BE RELOCATED OR REINSTALLED TO BE CLEANED, SERVICED AND PREPARED FOR PROPER RE-USE. ANY ITEMS STORED DURING CONSTRUCTION ARE TO BE PROTECTED TO AVOID DAMAGE OR THEFT 6. ALL ITEMS INDICATED AS EXISTING TO REMAIN , SHALL BE CLEANED, SERVICED AND PREPARED FOR PROPER CONTINUED RE-USE. PROTECT ALL ITEMS SUFFICIENTLY DURING CONSTRUCTION TO AVOID DAMAGE OR THEFT. 7. COOPERATE AND COORDINATE WITH LANDLORD, THE TENANTS OF THE ADJACENT SPACES AND THE TENANT, IN SCHEDULING WORK IN ORDER TO CAUSE THE LEAST INCONVENIENCE TO PERSONNEL AND PROPERTY. i. LUMBER, 2 INCHES AND LESS IN THICKNESS: 19 PERCENT. 3. THOROUGHLY CLEAN FLOOR SLAB REMOVING CONDITIONS THAT WILL AFFECT BOND RESIDUE FROM REMOVAL OF ADHESIVES, UNDERLAYMENTS, STAINS, OILS, ETC. ii. PLYWOOD: 15 PERCENT INCLUDING b) FLAME SPREAD: FIRE RETARDANT TREATED MATERIALS TO HAVE FLAME SPREAD RATING OF 25 OR LESS IN A 30 MINUTE TEST WITH NO EVIDENCE OF SIGNIFICANT PROGRESSIVE COMBUSTION, ASTM E 84, ADDITIONALLY, FLAME FRONT NOT TO PROGRESS MORE THAN 10 1/2 FEET BEYOND CENTER LINE OF BURNER AT ANY TIME. c) SMOKE DEVELOPED: INTERIOR FINISH AND TRIM MATERIALS, WHERE SPECIFIED, TO HAVE FIRE RETARDANT TREATMENT CONFORMING TO ABOVE REQUIREMENTS FOR "FLAME SPREAD" PLUS SMOKE DEVELOPED RATING OF 25 OR LESS, ASTM E 84. B. C. D. E. THE CONTRACTOR SHALL REMOVE, REPAIR, RESTORE, AND REPLACE WHERE ANY SUCH WORK IS NECESSARY OR AS INDICATED ON THE DRAWINGS. CUT ALL NECESSARY OPENINGS, AND PATCH/REPAIR/SEAL SAME TO DEGREE NECESSARY TO SATISFY ALL REQUIREMENTS. INSOFAR AS POSSIBLE, ALL PROTRUSIONS, MARKS, CRACKS OR OTHER EVIDENCE OF A DEFICIENT OR DAMAGED CONDITION SHALL BE ELIMINATED, UNLESS SPECIFICALLY NOTED OTHERWISE. ANY PARTS WHICH ARE SPLIT, CRACKED, CHIPPED, SPALLED, BROKEN, MISSING, OR OUT OF LINE OR ADJUSTMENT, MECHANICALLY OR STRUCTURALLY UNSAFE OR UNSOUND, BENT, TORN OR OTHERWISE DEFICIENT OR INJURED IN ANY MANNER, SHALL BE REMOVED, REPLACED, RESTORED OR REPAIRED. LANDLORD'S REPRESENTATIVE, ARCHITECT, AND TENANT'S CONSTRUCTION MANAGER MUST BE NOTIFIED IMMEDIATELY OF ANY STRUCTURAL OR SAFETY DEFECTS, AND ONLY THE TENANT'S CONSTRUCTION MANAGER IF THE DEFECT(S) ARE LIMITED TO COSMETIC FINISHES. EXERCISE EXTREME CARE DURING DEMOLITION SO AS NOT TO DAMAGE OR DISRUPT ANYUTILITY OR SPRINKLER LINES WHICH MIGHT PASS THROUGH THIS SPACE TO SERVICE OTHER MALL SPACES OR TENANTS. GENERAL CONTRACTOR WILL BEAR SOLE RESPONSIBILITY OF ANY SUCH DISRUPTION OR DAMAGE. ALL ABANDONED ELECTRICAL AND TELEPHONE CONDUIT, PLUMBING LINES, DRAIN LINES, AND ALL MECHANICAL ITEMS SHALL BE CAPPED AT SOURCE AND REMOVED IN A MANNER TO MEET ALL LANDLORD AND CODE REQUIREMENTS, UNLESS DIRECTED OTHERWISE. 3. GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING, REPAIRING AND LEVELING OF THE EXISTING FLOOR SLAB, REPAIR OF DEMISING WALLS AND ROOF DECK AFTER COMPLETION OF ALL DEMOLITION AND PRIOR TO THE COMMENCEMENT OF NEW CONSTRUCTION.COORDINATE WITH LANDLORD RESPONSIBILITY IN PERFORMING ANY AND ALL ROOF WORK. NO WORK UNDER THIS SECTION A. DIVISION 05000 - METALS 05120 STRUCTURAL STEEL PART 1 - GENERAL REINFORCEMENT (PER LANDLORD REQUIREMENTS) E. BONDING AGENT (IF REQUIRED) F. VAPOR BARRIER PROVIDE 14 GA. REINFORCEMENT AT CLOSER AND LOCKS AND 8 GA. REINFORCEMENT AT HINGES. FRAME - 12 GA. COLD ROLLED STEEL, ARC WELDED AT CORNERS AND GROUND SMOOTH AS MANUFACTURED BY STEELCRAFT OR EQUAL. FRAMES TO BE PHOSPHATIZED AND RECEIVE ONE COAT BAKED ON PRIMER READY TO RECEIVE PAINT. a. PROVIDE 14 GA. REINFORCEMENT AT CLOSER AND LOCKS AND 8 GA. REINFORCEMENT AT HINGES. PART 2 - PREPARATION / EXECUTION A. INSTALL FRAMES IN ACCORDANCE WITH SDI-100. B. COORDINATE WITH MASONRY WALL CONSTRUCTION FOR ANCHOR PLACEMENT. C. COORDINATE INSTALLATION OF FRAMES WITH INSTALLATION OF HARDWARE SPECIFIED IN DOOR SCHEDULE. 1. FOLLOW DOOR HARDWARE INSTITUTE (DHI) GUIDELINES. PART 1 - GENERAL A. THIS SECTION INCLUDES ALL ALUMINUM/GLASS DOORS, DOOR HARDWARE SPECIFICALLY SUPPLIED BY DOOR MANUFACTURER, EXTRUDED ALUMINUM GLAZING FRAMES COMPLETE WITH ACCESSORIES AND GLASS AS DETAILED ON THE DRAWINGS AND RESPONSIBILITY SCHEDULE. 1. ALUMINUM/TEMPERED GLASS ENTRANCE DOORS SHALL BE KAWNEER (SEE PARAGRAPH 2 OF THIS SECTION) SERIES 350 (SIZES OF VERTICAL STILE AND TOP RAIL AS PER PLANS AND DETAILS) SINGLE ACTING WITH 1/2" TEMPERED GLASS INFILL SET WITH ELASTOMERIC GASKETS. CLIENT COMMENTS COORDINATE PARAPET AND FLASHING NAILER INSTALLATION WITH INSTALLATION OF ROOFING. SEE SECTION 01005, E, "ROOF CUTTING AND PATCHING". C. INSTALL TELEPHONE AND ELECTRICAL PANEL BACK BOARDS WITH PLYWOOD SHEATHING MATERIAL WHERE REQUIRED. SIZE THE BACK BOARD BY 12 INCHES BEYOND SIZE OF ELECTRICAL PANEL. HINGING - TOP PATCH AND BOTTOM PIVOTS CLOSERS - NORTON SERIES 1600 - ONE PER DOOR LEAF LOCKS - DEADLOCK: "BEST CORE" b. MANUFACTURERS: KAWNEER COMPANY, INC. , NORCROSS, GA UNITED STATES ALUMINUM CORP., ROCK HILL SC c. FINAL FINISHES MUST MATCH EXACTLY. COLORS TO BE AS SPECIFIED ON FINISH SCHEDULE. B. ALUMINUM GLAZING FRAME. 1. KAWNEER (SEE PARAGRAPH 3 OF THIS SECTION) TRIFAB II 451 SERIES, (MULLION, RAIL, POST AND BASE SIZES AS PER PLANS AND DETAILS) FOR INFILL WITH 1/2" CLEAR TEMPERED GLASS. FOLLOW AWI (ARCHITECTURAL WOODWORK INSTITUTE) ARCHITECTURAL WOODWORK QUALITY STANDARDS. B. MILLWORK AND CABINETRY MAY BE SHOP OR FIELD ASSEMBLED AT CONTRACTORS OPTION. B. INSTALL PER MANUFACTURER'S RECOMMENDATIONS AND PROCEDURES. C. INSTALL ITEMS IN A RIGID, STRAIGHT, PLUMB, LEVEL MANNER ACCURATELY FITTED AND SCRIBED TO ABUTTING SURFACES. C. ALL JOINTS BETWEEN FRAMING AND BUILDING STRUCTURE SHALL BE SEALED TO PROVIDE WATERTIGHT INSTALLATION. D. INSTALL SEALANT AND BACKING MATERIALS AT PERIMETER OF FRAME. COUNTERSINK NAILS AND SCREW HEADS AND PATCH AND SAND SMOOTH. F. SHOP DRAWINGS: SUBMIT SHOP DRAWINGS TO ARCHITECT INDICATING SHOP AND ERECTION DETAILS, INCLUDING CUTS, CONNECTIONS, HOLES, THREADED FASTENERS AND WELDS. F. FINISH WOODWORK SHALL BE DRESSED AND SANDED, FREE FROM MACHINE AND TOOL MARKS, ABRASIONS, RAISED GRAIN OR OTHER DEFECTS. G. PRE-ASSEMBLE ITEMS IN SHOP TO GREATEST POSSIBLE EXTENT TO MINIMIZE FIELD SPLICING AND ASSEMBLY. DISASSEMBLE UNITS ONLY AS NECESSARY FOR SHIPPING AND HANDLING LIMITATIONS. CLEARLY MARK UNITS FOR RE-ASSEMBLY AND COORDINATE INSTALLATION. G. PROTECT FINISHED WORK UNTIL ACCEPTANCE BY TENANT. H. WELDING PROCEDURES, WELDERS, WELDING OPERATIONS AND TACKERS SHALL BE QUALIFIED ACCORDANCE WITH AWS-D1.1- "STRUCTURAL WELDING CODE". I. FABRICATOR SHALL BE A MEMBER OF AMERICAN INSTITUTE OF STEEL CONSTRUCTION. A. J. FABRICATE STRUCTURAL STEEL IN ACCORDANCE WITH AISC "SPECIFICATIONS FOR DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" AND "CODE OF STANDARD PRACTICE". PART 2 - PREPARATION / EXECUTION 2. WHERE FASTENING SPACINGS OR SIZES ARE NOT SHOWN, CONTRACTOR SHALL USE SPACINGS AND SIZES OF BOLTS, SCREWS, WELDS, ETC., WHICH WILL DEVELOP THE FULL STRENGTH OF THE MEMBERS BEING FASTENED. THUS FAILURE DUE TO OVER-STRESSING MUST OCCUR IN THE MEMBERS BEFORE OCCURRING IN THE FASTENINGS. PART 2 - PREPARATION / EXECUTION A. PRE-ASSEMBLE ITEMS IN SHOP TO GREATEST POSSIBLE EXTENT TO MINIMIZE FIELD SPLICING AND ASSEMBLY. DISASSEMBLE UNITS ONLY AS NECESSARY FOR SHIPPING AND HANDLING LIMITATIONS. CLEARLY MARK UNITS FOR RE-ASSEMBLY AND COORDINATE INSTALLATION. 06424 LAMINATES PART 1 - GENERAL B. SEE DOOR SCHEDULE FOR SPECIFIC ITEMS, MANUFACTURERS AND MODEL NUMBERS. C. FOLLOW DHI (DOOR AND HARDWARE INSTITUTE) STANDARDS AND GUIDELINES AND AWI (AMERICAN WOODWORKING INSTITUTE) STANDARDS FOR HARDWARE INSTALLED ON WOOD DOORS. D. FIRE RATED HARDWARE SHALL FOLLOW GUIDELINES AS ESTABLISHED BY: 3. NFPA 252 - FIRE TESTS OF DOOR ASSEMBLIES. 4. UL 10B - SAFETY FIRE TESTS OF DOOR ASSEMBLIES. B. SEE MILLWORK SECTION FOR TYPICAL NOTES AND REFERENCES. 5. UL 305 - SAFETY PANIC HARDWARE. E. FURNISH OWNER WITH MAINTENANCE DATA, MAINTENANCE PROCEDURES, MANUFACTURERS WARRANTIES AND SPECIAL TOOLS. F. FINISHES: AS NOTED ON PLANS AND SCHEDULES. G. KEYING 2. GENERAL CONTRACTOR TO INSTALL CONSTRUCTION CORES DURING CONSTRUCTION AND REPLACE WITH PERMANENT AT END OF JOB PRIOR TO TURN-OVER. PART 1 - GENERAL BATT INSULATION H. SEE SECTION ON ALUMINUM ENTRANCES FOR HARDWARE SPECIFIC TO THOSE DOORS I. MANUFACTURERS: 1. HINGES: STANLEY FBB 179 AVERAGE FREQUENCY, OR EQUAL. EXTERIOR DOORS TO RECEIVE TAMPERPROOF BUTTS AND/OR LATCH GUARDS. 2. STRUCTURAL STEEL TUBING: FY 46 KSI COLD-FORMED TUBING EXCEPT ROUND, ASTM A500-68, GRADE B. 1. FURNISH AND INSTALL 3 1/2" MIN. THERMAL BATT TYPE INSULATION AT EXTERIOR WALLS OR AS SOUND ATTENUATION BLANKET WHERE SHOWN AND AS SPECIFIED ON DRAWINGS. 3. STEEL PIPE: ASTM A53, GRADE B. 2. EXTEND FROM FLOOR TIGHT TO ROOF DECK ABOVE. 2. LOCKSETS/LATCHES: SCHLAGE D-SERIES, SPARTA DESIGN w/ROSE, OR EQUAL. LOCKSETS TO RECEIVE INTERCHANGEABLE CORE CYLINDERS TO ACCEPT "BEST CORE". SEE KEYING NOTES THIS SECTION. 3. FURNISH AND INSTALL .004 MIL. VISQUEEN VAPOR BARRIER AT EXTERIOR WALLS ON WARM SIDE OF STUDS. 3. CLOSERS: NORTON - POWER ADJUSTABLE CLOSER FOR BARRIER FREE OPERATION. SERIES 8301 BF OR EQUAL. 4. ANCHOR BOLT: CONFORM TO ASTM A307. 5. WELDING ELECTRODES: ASTM A233, E-70 OR BETTER. C. 6. HIGH STRENGTH THREADED FASTENERS: ASTM A325 OR A-490. 7. METAL STUDS: SIZE ACCORDING TO CONSTRUCTION DOCUMENTS x 20 GAUGE STEEL AT 16" O.C. TRACKS TO BE ANCHORED BY MEDIUM POWER ACTUATED FASTENERS @ 24" O.C. 8. EXTERIOR / INTERIOR METAL STUDS: SIZE ACCORDING TO CONSTRUCTION DOCUMENTS X 25 GAUGE AT 16" O.C.. 9. SHOP PAINT PRIMER: STANDARD PRIMER: D. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WATERPROOFING MEMBRANE OVER ENTIRE FLOOR OF REST ROOMS BELOW FINISH FLOORING AND UP WALL A MIN. 4". (ONLY WHERE REST ROOMS ARE LOCATED ABOVE ANOTHER FLOOR.) APPLY PER MANUFACTURERS INSTRUCTIONS AND CAULK AS REQ'D. TO MATCH ADJACENT FINISHES. G.C. SHALL SLEEVE, FIRESTOP, FLASH AND CAULK ALL PENETRATIONS OF FLOORS SO THAT ODORS OR LIQUIDS WILL NOT PENETRATE THE SLAB AT THESE OPENINGS. SUCH SLEEVES SHALL BE INSTALLED ACCORDING TO THE LANDLORD STANDARD DETAILS 07900 JOINT SEALERS / CAULKING a. SSPC PAINT 15 PART 1 - GENERAL b. TNEMEC 1009 GRAY METAL PRIMER A. c. MARTIN-SENOUR CO. #664 RED OXIDE ZINC CHROMATE PRIMER PROVIDE AND INSTALL EXPANSION JOINT MATERIAL, SEALANTS AND JOINT BACKING FOR JOINTS BETWEEN DISSIMILAR MATERIALS. 1. SILICONE SEALANTS (TYPE S): ASTM C920, SINGLE COMPONENT, NON-SAGGING, NON-STAINING, NON-BLEEDING; FOR USE AS GENERAL CAULKING. COLOR TO MATCH ADJACENT SURFACES. MANUFACTURER BY GE SILICONES OR EQUAL.2. JOINT BACKING: ROUND, OPEN CELL POLYETHYLENE FOAM ROD. d. PRATT AND LAMBERT NOXIDE 107, ONE DAY PRIMER-GRAY. E. STEEL SHALL BE CLEAN AND FREE FROM OIL, DIRT, LOOSE MILL SCALE AND ANY OTHER SUBSTANCE THAT WOULD IMPAIR WELDING, PERFORMANCE OF FRICTION-TYPE BOLTED. Seal 1. GENERAL CONTRACTOR TO COORDINATE KEYING AND MASTER KEYING WITH CONSTRUCTION MANAGER. 07200 INSULATION AND WATERPROOFING B. 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 1. NFPA 80 - FIRE DOORS AND WINDOWS. FOLLOW MANUFACTURERS GUIDELINES AND RECOMMENDATIONS FOR ADHESIVE AND SUBSTRATE PREPARATION. FOR INSULATION REQUIRED AT DUCKWORK, PLUMBING LINES, ETC. SEE MECHANICAL / ELECTRICAL SPECIFICATIONS AND DRAWINGS. 20474 08710 DOOR HARDWARE A. A. REG NO: VERIFY DIMENSIONS, TOLERANCES AND ATTACHMENTS AND SHIMS TO PERMIT SUFFICIENT ADJUSTMENTS TO ACCOMMODATE IRREGULARITIES. 2. NFPA 101 - LIFE SAFETY CODE. DIVISION 07000 - THERMAL AND MOISTURE PROTECTION 07-01-16 PART 1 - GENERAL A. FURNISH AND INSTALL FINISH HARDWARE FOR INTERIOR AND EXTERIOR DOORS, ROLLING GRILLES AND WINDOWS. INSTALL HIGH PRESSURE LAMINATES AS SPECIFIED IN FINISH SCHEDULE AND AS DETAILED IN DRAWINGS. END OF DIVISION DATE: Engineer A. CUTTING AND REPAIRING OF THIS WORK FOR ACCOMMODATION OF WORK BY OTHERS SHALL BE DONE AS PART OF MILLWORK RESPONSIBILITY. GLENN S. YEAKEL EXTERIOR - 1/2" CLEAR INSULATED GLASS FOR INFILL INTO GLAZING FRAME. PART 2 - PREPARATION / EXECUTION E. 1. UNLESS OTHERWISE SHOWN, FABRICATOR SHALL DESIGN / DETAIL CONNECTIONS IN CONFORMANCE WITH AISC STANDARD FOR FORCES AND MOMENTS SHOWN. 1. DO NOT DELIVER OR INSTALL ITEMS UNTIL BUILDING AND ROOMS RECEIVING SUCH ARE COMPLETED AND THOROUGHLY DRY AND FREE OF EXCESSIVE MOISTURE. D. NAME: GLAZING A. VERIFY THE EXACT SIZE AND LOCATION OF ALL OPENINGS PRIOR TO FABRICATION OF STEEL FRAMING MEMBERS. IN C. PART 2 - PREPARATION / EXECUTION E. Seal THRESHOLD - MILL FINISH ALUMINUM MAXIMUM 1/2" HIGH C. PROVIDE OPENINGS AND SPECIAL FRAMING REQUIRED BY OTHER TRADES. MECHANICAL FRAMING LOADS, OPENINGS, AND STRUCTURE RELATED TO MECHANICAL REQUIREMENTS ARE SHOWN FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL OBTAIN WRITTEN SIGN-OFF FROM MECHANICAL AND OTHER TRADES FOR SPECIFIC REQUIREMENTS BEFORE PROCEEDING WITH SUCH WORK. ARCHITECT'S OR ENGINEER'S APPROVAL OF ERECTION AND SHOP DRAWINGS SHALL NOT RELIEVE CONTRACTOR FROM THIS RESPONSIBILITY. 2016-026A PUSH/PULL - KAWNEER "F-2" SET MEMBERS LEVEL AND PLUMB, IN CORRECT POSITION. B. 281 Farmington Avenue Farmington, CT. 06032 a. HARDWARE - TO INSURE SINGLE SOURCE RESPONSIBILITY, THE FOLLOWING SHALL BE PROVIDED AND INSTALLED BY THE DOOR SUPPLIER / INSTALLER SEE DRAWINGS AND RESPONSIBILITY SCHEDULE FOR DETAILS, SIZES, DIMENSIONS. SHOP CONNECTIONS SHALL BE WELDED. 07/19/16 ASSOCIATES INC. 08400 ALUMINUM ENTRANCES AND STOREFRONTS B. FIELD CONNECTIONS: HIGH STRENGTH FASTENERS SHALL BE USED FOR BOLTED CONNECTIONS. Description SUBMIT FOR PERMIT Architect of Record b. INSTALL MINIMUM THREE (3) JAMB ANCHORS AND BASE ANCHORS EACH SIDE. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE PROJECT IS FULLY COMPLETED. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND TO INSURE STABILITY OF THE BUILDING AND ITS COMPONENT PARTS AND ADEQUACY OF TEMPORARY SUPPORT DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER TEMPORARY BRACING, GUY OR TIE DOWNS MIGHT BE NECESSARY. SUCH MATERIAL IS NOT SHOWN ON DRAWINGS. IF APPLIED, THEY SHALL BE REMOVED AS CONDITIONS PERMIT AND SHALL REMAIN CONTRACTOR'S PROPERTY. NAME: DATE: 4. THRESHOLDS, SWEEPS AND WEATHER STRIPPING: THERMAL BARRIER SADDLE THRESHOLD - PEMKO #252X2AFG, MAXIMUM HEIGHT 1/2", OR EQUAL. DOOR BOTTOM SWEEP - PEMKO #315CN, OR EQUAL. REG NO: RIGID JAMB WEATHERSTRIP - PEMKO #303AV, OR EQUAL. 5. STOPS, KICKPLATES AND SILENCER; WALL STOP - IVES #407, OR EQUAL FLOOR STOP - IVES #436, OR EQUAL DOOR SILENCER - Nextore project Number 73052 IVES #20, OR EQUAL KICKPLATE - IVES #8400, 8" HIGH X FULL WIDTH OF DOOR, OR EQUAL SCREW TO MATCH KICKPLATE. ONE-WAY VIEWER (PEEP) - IVES #696, OR EQUAL. ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction PART 2 - PREPARATION / EXECUTION 05400 METAL FRAMING LIGHT GAUGE (COLD-FORMED) METAL FRAMING A. REMOVE LOOSE MATERIALS AND FOREIGN MATTER WHICH MIGHT IMPAIR ADHESION OF SEALANT. B. CLEAN AND PRIME JOINTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. C. PROTECT ELEMENTS SURROUNDING THE WORK OF THIS SECTION FROM DAMAGE OR DISFIGURATION. PART 1 - GENERAL D. INSTALL SEALANT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. A. E. INSTALL JOINT BACKING. F. APPLY SEALANT WITHIN RECOMMENDED APPLICATION TEMPERATURE RANGES. CONSULT MANUFACTURER WHEN SEALANT CANNOT BE APPLIED WITHIN THESE TEMPERATURE RANGES. FURNISH AND INSTALL A COMPLETE SYSTEM OF LIGHT GAUGE FRAMING MEMBERS FOR INTERIOR WALL PARTITIONS AND CEILING SUSPENSION COMPONENTS. 1. SYSTEM TO INCLUDE ALL TOP AND BOTTOM RUNNERS, BRACES, CLIP ANGLES, ACCESSORIES, FASTENERS, ETC. FOR EACH TYPE OF FRAMING AS SHOWN ON DRAWINGS. a. INSTALL METAL FRAMING SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. PART 2 - PREPARATION / EXECUTION CONCRETE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR STRENGTH, CONSISTENCY PROPORTIONS AND HANDLING OF CONCRETE. SEE DOOR SCHEDULE FOR REQUIRED HARDWARE. SEE STRUCTURAL DOCUMENTS FOR ADDITIONAL SPECIFICATIONS / STANDARDS. 1. SLAB ON GRADES TO RECEIVE 6 MIL. CLEAR OR BLACK POLYETHYLENE FILM WITH MINIMUMOF 12" OVERLAP. TAPE ALL SEAMS. A. 2. a. b. C. C. 1 By 1. DOORS THERMALLY INSULATED L-16 WITH POLYSTYRENE CORE (R=7.7): SDI-100 GRADE AS MANUFACTURED BY STEELCRAFT, CINCINNATI, OHIO, OR EQUAL. FRAMES TO BE PHOSPHATIZED AND RECEIVE ONE COAT BAKED ON PRIMER READY TO RECEIVE PAINT. B. B. Date 07/07/16 PART 1 - GENERAL A. NON-RATED THERMALLY INSULATED STEEL DOORS AT EXTERIOR OPENINGS. 4. FINAL FINISH MUST MATCH EXACTLY COLORS AS SPECIFIED ON FINISH SCHEDULE, IF EXACT COLOR IS NOT AVAILABLE THROUGH MANUFACTURER PAINT CONTRACTOR SHALL FIELD PAINT. 889 VALLEY PARK DRIVE 3. ASTM C881 COORDINATE INSTALLATION OF FRAMES WITH INSTALLATION OF DOORS AND HARDWARE AS SPECIFIED IN DOOR SCHEDULE AND ON DRAWINGS. FURNISH AND INSTALL FINISHED TRIM, CABINETRY, COUNTERS, DOORS, AND ALL FINISH ITEMS SUCH AS LAMINATES AND FINISH DOOR HARDWARE, AS INDICATED AND DETAILED ON PLANS. a. MANUFACTURER: CHEMTREX, INC. 2. CONSULT MANUFACTURER FOR APPLICATION PROCEDURE. COORDINATE WITH WALL CONSTRUCTION FOR ANCHOR PLACEMENT. C. A. 1. "SONOBOND" EPOXY CONCRETE BONDING AGENT OR EQUAL SHAKOPEE, MINNESOTA 55379-1854 B. 3. MANUFACTURERS: KAWNEER COMPANY, INC., NORCROSS, GA UNITED STATES ALUMINUM CORP., ROCK HILL, SC D. Revisions: Mark 06210 MILLWORK AND FINISH CARPENTRY CLASS 1 3000 PSI INTERIOR SLABS (OR MIN.REQUIRED PER D. PROVIDE 8 GA. REINFORCEMENT AT HINGES AND 14 GA. REINFORCEMENT AT LOCK AND CLOSERS. INSTALL ADJUSTABLE JAMB ANCHOR 4" DOWN FROM HEAD AND WELDED-IN BASE ANCHOR AT EACH JAMB. PART 1 - GENERAL PROVIDE AND INSTALL CONCRETE AS INDICATED ON THE DRAWINGS. CONCRETE STRENGTHS ARE AS FOLLOWS: LANDLORD SPECIFICATIONS.) a. b. PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY FOR COMPLETE INSTALLATION OF STEEL FRAMING AND SUPPORT MEMBERS, ANGLES, PLATES, ANCHOR BOLTS REQUIRED FOR THE CONNECTION, SETTING AND BEARING OF COMPLETE STRUCTURE AS SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN. DIVISION 03000 - CONCRETE 03300 CAST-IN-PLACE CONCRETE C. SURFACES TO BE 2. PROVIDE AND INSTALL ALL INTERNAL SUPPORT FRAMING, RELATED FLASHINGS, ANCHORAGE AND ATTACHMENT DEVICES. END OF DIVISION CONCRETE WORK SHALL CONFORM TO THE LATEST EDITION OF "AMERICAN CONCRETE INSTITUTE" CODES AND STANDARDS INCLUDING ACI 301, ACI 315, AND ACI 318. PROVIDE 8 GA. REINFORCEMENT AT HINGES, AND 14 GA. REINFORCEMENT AT LOCK AND CLOSERS. 3. TELEPHONE AND ELECTRICAL PANEL BACK BOARDS. PART 2 - PREPARATION / EXECUTION 1. STRUCTURAL STEEL FY 36 KSI STEEL, ASTM A36. B. SEE DOOR SCHEDULE FOR REQUIRED HARDWARE. INSTALL FRAMES IN ACCORDANCE WITH SDI-100. d. STORE TREATED MATERIALS FOR EASY IDENTIFICATION AND PROTECT FROM MOISTURE; PROVIDE WELL VENTILATED DRY STORAGE. DIVISION 04000 - MASONRY GENERAL CONTRACTOR RESPONSIBILITIES 2. GENERAL CONTRACTOR IS TO ERECT CONSTRUCTION BARRICADES AND DEBRIS/DUCT SCREENS PER LANDLORD'S SPECIFICATIONS. CONTACT LANDLORD'S REPRESENTATIVE PRIOR TO THE COMMENCEMENT OF ALL DEMOLITION WORK. a. b. 2. FRAMES - 2" FRONT FACE - 16 GA. HOLLOW METAL WITH CONTINUOUSLY WELDED CORNERS. PHOSPHATIZED AND RECEIVE ONE COAT BAKED ON PRIMER READY TO RECEIVE PAINT. c. DELIVER TREATED MATERIALS BUNDLED AND MARKED TO IDENTIFY TREATMENT. f. FIELD CUTS AND HOLES: FIELD-TREAT IN ACCORDANCE WITH AWPA M-4. 1. GENERAL CONTRACTOR IS TO NOTIFY TENANT IMMEDIATELY OF ANY SEVERE DISCREPANCIES OR IRREGULARITIES DISCOVERED DURING DEMOLITION WHICH MIGHT AFFECT THE CURRENT STORE DESIGN. GENERAL CONTRACTOR IS TO PAY SPECIAL ATTENTION TO AVAILABLE HEIGHT FOR INTENDED CEILING ELEVATION, MECHANICAL DUCTWORK AND RECESSED LIGHTING. A. b. CERTIFICATES: FURNISH AFFIDAVIT IF REQUIRED BY CODE OFFICIAL STATING THAT MATERIALS HAVE BEEN TREATED IN ACCORDANCE WITH SPECIFICATIONS AND THAT MOISTURE CONTENT, AFTER TREATMENT, DOES NOT EXCEED SPECIFIED LIMITS; INCLUDE CHEMICAL USED AND RETENTION OBTAINED FOR PRESSURE TREATED MATERIAL. INCLUDE THE "QUALITY MARK" OF ASSOCIATION HAVING JURISDICTION OVER THE TREATMENT. e. HANDLE TREATED MATERIALS IN ACCORDANCE WITH AWPA STANDARDS. IN ADDITION TO USED IN TREATMENT, FURNISH ADDITIONAL MATERIAL FOR FIELD TREATMENT \ MATERIAL OF CUTS. A. Macy's Store Number: (687) 1. DOORS - 1 3/4" THICK FLUSH MOUNTED "TYPE B" AS MANUFACTURED BY STEELCRAFT. SURFACES TO BE PHOSPHATIZED AND RECEIVE ONE COAT BAKED ON PRIMER READY TO RECEIVE PAINT. AND IN END OF DIVISION 8. SEE MECHANICAL AND ELECTRICAL PLANS FOR SPECIFIC DEMOLITION ITEMS UNDER THOSE TRADES. PART 2 - PREPARATION / EXECUTION A. ARRANGE WITH THE LANDLORD A CONVENIENT TIME TO PERFORM DEMOLITION WORK AND INSTALL TEMPORARY PROTECTED MEANS OF EGRESS FROM REQUIRED EXITS. INCLUDE TEMPORARY LIGHTING AND SAFETY DEVICES, ALL IN ACCORDANCE WITH GOVERNING STATE AND LOCAL CODES AND LAND-LORD REQUIREMENTS. INTERIOR HOLLOW METAL DOORS AND FRAMES FOR INSTALLATION AT DRYWALL AND METAL STUD PARTITIONS. PERFORMANCE REQUIREMENTS: 2. REMOVE AND DISPOSE OF EXISTING FLOOR FINISHES WHERE INDICATED ON DEMOLITION PLAN. 9. CLEAN AREAS REMOVING ALL WASTE MATERIAL, BROOM CLEAN. 2. CONSULT DEMOLITION PLANS INCLUDED WITH PROJECT DOCUMENTS FOR ADDITIONAL NOTES AND SITE SPECIFIC ITEMS. D. a) MOISTURE CONTENT: AFTER TREATMENT, THE MAXIMUM MOISTURE CONTENT OF WOOD MATERIALS SHALL NOT EXCEED THE FOLLOWING: 8. TRENCH ONLY AT SLAB ON GRADE. VERIFY AND GET APPROVAL OF TRENCH OR CORE LOCATIONS WITH THE LANDLORDS REPRESENTATIVE AND MALL STRUCTURE PRIOR TO COMPLETING ANY WORK. CORES TO BE SEALED WATERPROOF. SEE SECT. 07200 "INSULATION AND WATERPROOFING" FOR ADDITIONAL WATERPROOFING INFORMATION. 1. THIS SECTION IS INCLUDED FOR GENERAL REFERENCE OF WORK TO BE REMOVED BY THE GENERAL CONTRACTOR. FABRICATE AND ERECT TRUE, PLUMB AND SQUARE AS SPECIFIED AND AS DETAILED AND PER MANUFACTURER'S RECOMMENDATIONS. a. PRESERVATIVE TREATMENT FOR WOOD SPECIFIED ELSEWHERE. 7. AT LOCATIONS OF CONSTRUCTION JOINTS IN EXISTING SLAB, CONTINUE JOINTS THROUGH NEW FLOOR IN LEVELING AREA. SAW CUT JOINT OR PLACE 1/16" WIDE METAL BAR IN THE JOINT LOCATION COINCIDENT WITH EXISTING. SELECTIVE DEMOLITION C. 2. USE NON-COMBUSTIBLE FIRE RETARDANT TREATED (F.R.T.) WOOD ELSEWHERE AS REQUIRED BY STATE AND LOCAL CODES, INCLUDING ANY WOOD STUDS, BLOCKING, FURRING, PLYWOOD, TRIM AND GROUNDS. NEW LUMBER TO BEAR GRADE AND TREATMENT OF ASSOCIATION UNDER WHICH IT WAS PRODUCED. 5. ROUGH IN CONCRETE IN AREAS WHERE PATCHING IS REQUIRED, SUCH AS CRACKED, SPALLED, OR HOLES DUE TO REMOVAL OF EXISTING WORK. PART 1 - GENERAL PART 1 - GENERAL BIDDING CONTRACTORS SHALL PREPARE A BID, WHICH SHALL BE SUBMITTED IN ACCORDANCE WITH INSTRUCTIONS TO BIDDERS CONTAINED WITHIN BID DOCUMENT PACKAGE. 1. BLOCKING AND GROUNDS AT STOREFRONT GLAZING , LOCATIONS AT WEATHER AREAS, CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. 4. REMOVE HIGH FLOOR LEVELS AND LOOSE CONCRETE. DIVISION 02000 - SITE WORK 02060 BUILDING DEMOLITION HARDWARE AND RELATED PARTS AND MATERIALS AS INDICATED ON DRAWINGS AND 08110 INSULATED STEEL DOORS PROVIDE AND INSTALL WOOD FURRING, BLOCKING, GROUNDS AND IN-WALL BLOCKING FOR SUPPORT OF GRAB BARS, FIXTURES, EQUIPMENT, CASEWORK, HARDWARE, TRIM AND SIMILAR WORK. 6. GRIND HIGH SPOTS. 01200 PRICE, PAYMENT, AND CONTRACT A. A. 1. DO NOT PROCEED WITH WORK UNTIL VISITING THE SITE AND DETERMINING CONDITIONS TO DECIDE METHODS OF REPAIR. COORDINATE WITH TENANT'S CONSTRUCTION MANAGER. END OF DIVISION +1 (516) 393-2484 1. FOLLOW DOOR HARDWARE INSTITUTE (DHI) GUIDELINES. COMPLY WITH MANUFACTURER'S REQUIREMENTS FOR INSTALLATION OF ITEMS AND FINISHES BY OTHER TRADES, INCLUDING THOSE ITEMS AND FINISHES PROVIDED AND/OR INSTALLED BY TENANT. PART 1 - GENERAL PART 1 - GENERAL MANUFACTURERS: B. WARRANTIES AND BONDS LABELED DOORS: WHERE REQUIRED, PROVIDE U.L. LABEL DOORS AND FRAMES PER APPLICABLE STATE AND LOCAL BUILDING CODES. SUCH TO RECEIVE LABELS ATTACHED STATING RATINGS. A. 06100 WOOD BLOCKING AND CURBING OPERATION AND MAINTENANCE DATA B. c. WELDING: COMPLY WITH AWS D1.1 "STRUCTURAL WELDING CODE". PART 1 - GENERAL A. INSTALL ALL DOORS, FRAMES, RESPONSIBILITY SCHEDULE. PART 2 - PREPARATION /EXECUTION 1. MILCOR / DIVISION OF INRYCO, INC. BY BOSTWICK STEEL FRAMING, THE CECO ALLIED STRUCTURAL INDUSTRIES; DIETRICH INDUSTRIES OR EQUAL. PART 2 - PREPARATION / EXECUTION ADJUSTING A. b. ANCHORAGE DEVICES: POWER ACTUATED FASTENERS, DRILLED EXPANSION BOLTS, OR SCREW WITH SLEEVES. THE EXTENT OF CONCRETE REPAIR WORK INCLUDES REMAINING FLOOR AREAS AFTERDEMOLITION PROVIDING A LEVEL FLOOR THROUGHOUT TO RECEIVE FUTURE FINISHES. 1. EXECUTE AND ASSEMBLE TRANSFERABLE WARRANTY DOCUMENTS FROM SUBCONTRACTORS, SUPPLIERS, AND MANUFACTURERS. DELIVERIES 01041 PROJECT COORDINATION D. +1 (513) 765-6000 p PART 1 - GENERAL a. MANUFACTURER'S RECOMMENDED SELF-DRILLING, SELF-TAPPING SCREWS, BOLTS, NUTS AND WASHERS. NON-CORROSIVE. A. 2. PREPARE BINDER COVER WITH PRINTED TITLE "OPERATION AND MAINTENANCE INSTRUCTIONS", WITH TITLE OF PROJECT, LOCATION AND DATE, AND SUBMIT TO TENANT'S CONSTRUCTION MANAGER. 3. ROOF REPAIRS OR PENETRATIONS REQUIRED BY REMOVAL OR RELOCATION OF EXISTING EQUIPMENT OR INSTALLATION OF NEW EQUIPMENT (CUTTING OF ROOF AND DECK MATERIAL AND/OR REPAIR OF THE SAME) SHALL BE COORDINATED WITH THE LANDLORD'S REPRESENTATIVE. 2. THE GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE ACCEPTABLE HOURS FOR DELIVERY AND LOCATION OF DELIVERY OF BUILDING PRODUCTS AND TENANTS ITEMS WITH LANDLORD'S REPRESENTATIVE. EXPANSION JOINT MATERIAL: 1/2" PRE MOLDED ASPHALT IMPREGNATED FIBERBOARD, SAME DEPTH AS CONCRETE. p 6 Creamery Brook, East Granby, CT 06026 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 08100 HOLLOW METAL DOORS AND FRAMES 5. FASTENINGS: PART 1 - GENERAL 1. SUBMIT DATA BOUND IN 8-1/2x11 INCH TEXT PAGES, THREE D SIDE RING BINDER WITH DURABLE PLASTIC COVERS. 4. ALL SUB TRADES SHALL COORDINATE REMOVAL OF DEBRIS AND GARBAGE GENERATED BY THEIR TRADES WITH THE G.C. 1. GENERAL CONTRACTOR IS RESPONSIBLE FOR UNLOADING ALL TENANT PROVIDED ITEMS AT THE JOB SITE INCLUDING A HEAVY AMOUNT OF MILLWORK WHICH IS TENANT SUPPLIED. THESE TENANT SUPPLIED ITEMS SHALL BE THE G.C.'S RESPONSIBILITY TO UNLOAD, STORE, AND DELIVER TO PROPER STORE AREAS WHEN REQUIRED. SEE TITLE SHEET, "GENERAL NOTES", FOR ADDITIONAL NOTES, PROCEDURES, AND RESPONSIBILITIES. APPLY BONDING AGENT (AS SPECIFIED) TO ADJACENT CONCRETE SURFACES IMMEDIATELY PRIOR TO PLACEMENT OF CONCRETE. FINAL CLEANING 1. ADJUST OPERATING PRODUCTS AND EQUIPMENT TO ENSURE SMOOTH AND UNHINDERED OPERATION. 3. THERE WILL BE NO STORAGE OF MATERIAL OR RUBBISH IN CORRIDORS OR OTHER LANDLORDAREAS AT ANY TIME. IF DEBRIS IS FOUND IN THIS AREA, IT WILL BE REMOVED AT THE EXPENSE OF THE CONTRACTOR THAT IS RESPONSIBLE. F. PROVIDE SAW CUT CONTROL JOINTS 1/8" WIDTH x 1" DEEP AT MAXIMUM 400 SQUARE FOOT AREA. DIVISION 08000 - DOORS AND WINDOWS 4. TRACK: ASTM A446/A446M GRADE A; MINIMUM YIELD STRESS OF 33 KSI (228 MPA); FORMED STEEL: CHANNEL SHAPED; SAME WIDTH AND GAUGE AS ADJACENT STUDS. EXCEPTION: TOP AND BOTTOM TRACK (RUNNERS) REQUIRING ATTACHMENT OF METAL PANELS SHALL BE MINIMUM 14 GAUGE (0.08"/1.9MM). FINISHES J. 1. REMOVE WASTE AND SURPLUS MATERIALS, RUBBISH AND CONSTRUCTION DEBRIS FROM SITE. GENERAL CONTRACTOR TO PROVIDE A PROFESSIONAL CLEANING SERVICE TO EXECUTE FINAL CLEANING PRIOR TO TURN-OVER. SEE TITLE SHEET, "GENERAL NOTES", FOR ADDITIONAL INFORMATION. 2. MALL DOORS ARE NOT TO BE PROPPED OPEN BY CONSTRUCTION WORKERS AT ANY TIME. 2. THE LANDLORDS ROOFING CONTRACTOR WILL, AT SUBTRADES WRITTEN REQUEST AND COST, PROVIDE THE OPENINGS, ANCHORING DEVISES, CURBS, FLASHINGS, PATCHING, ETC., AS REQUIRED FOR TENANTS EQUIPMENT SO AS TO MAINTAIN THE INTEGRITY AND GUARANTEE OF THE ROOF. ALL SUBTRADES SHALL INCLUDE THE COST OF SUCH OPENINGS, ETC. IN THEIR PROPOSALS TO TO THE GENERAL CONTRACTOR DURING BIDDING. SUBTRADES SHALL COORDINATE WITH THE LANDLORD AND/OR ROOFING CONTRACTOR AND ALSO REIMBURSE HIM FOR SAME. GENERAL CONTRACTOR AND/OR SUB-CONTRACTOR ARE RESPONSIBLE AND SHALL INCLUDE IN THEIR BIDS ALL NECESSARY EQUIPMENT INCLUDING CRANES, HOISTS, SCAFFOLDING, PLATFORMS, ETC., REQUIRED FOR ERECTION OF BUILDING COMPONENTS, EQUIPMENT AND ALL TENANT SUPPLIED ITEMS AS LOCATED ON PLANS. CONTRACTOR SHALL PAY ALL RELATED FEES, PERMITS, ETC. PROTECTION OF THE PUBLIC AND EXISTING IN-PLACE WORK IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PART 1 - GENERAL 2. DESIGN LOADS: LOADS AND CODE RESTRICTIONS FOR ALL DESIGN CONSIDERATIONS SHALL CONFORM TO THE LOCAL AND STATE CODES AND ALL GOVERNING CODES. 1. CUTTING AND PATCHING FOR ALL ROOF OPENINGS SHALL BE PERFORMED BY LANDLORDS ROOFING CONTRACTOR, IF SO REQUIRED BY THE LANDLORD, ENGAGED BY TENANTS GENERAL CONTRACTOR. b. 12-16 GAUGE (0.11"/2.7MM - 0.06"/1.5MM): ASTM A446/A446M GRADE A; MINIMUM YIELD STRESS OF 40 KSI (276 MPA). COMPACT SUB GRADE FOR SLABS ON GRADE TO 95 CRUSHED GRAVEL SUB-BASE AT ALL AREAS TO RECEIVE NEW CONCRETE. I. MATERIALS: 1. 18 GAUGE AND LIGHTER COMPONENTS: FABRICATE COMPONENTS OF COMMERCIAL QUALITY STEEL SHEET, ASTM A446 FOR GALVANIZED FINISH WITH A MINIMUM YIELD POINT OF 33,000 PSI. 1. GIVE TYPICAL INTERIOR FLOOR SLABS A STEEL TROWEL FINISH WITH CLASS A TOLERANCE (TRUE PLANES WITHIN 1/8 IN 10 FT. AS DETERMINED BY A 10 FOOT STRAIGHTEDGE PLACED ANYWHERE ON SLAB IN ANY DIRECTION). K. 01700 CLEANING / ADJUSTING / MAINTENANCE / WARRANTIES CODES AND STANDARDS ROOF CUTTING AND PATCHING GENERAL CONTRACTOR TO VERIFY PROVISIONS FOR TEMPORARY UTILITIES INCLUDING ELECTRICITY, LIGHTING, HEAT, VENTILATION, TELEPHONE SERVICE, WATER AND SANITARY FACILITIES. G.C. TO INCLUDE A FULL TIME PHONE AND FAX ON SITE CAPABLE OF INCOMING CALLS DURING ENTIRE CONSTRUCTION PERIOD. C. PART 1 - GENERAL 1. ALL WORK, MATERIALS, AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH ALL ORDINANCES, STATE AND LOCAL BUILDING CODES, LATEST EDITION. SEE TITLE SHEET FOR SPECIFIC EDITIONS. E. H. 01542 CRANES AND HOISTS 4. SHOULD A CONTRACTOR FIND DISCREPANCIES IN, OR OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS, OR SHOULD HE BE IN DOUBT AS TO THEIR MEANING, HE SHALL AT ONCE NOTIFY THE ARCHITECT AND TENANT. 5. THE G.C. SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL DEBRIS INCLUDING PACKAGING MATERIAL OF MILLWORK. G. PART 1 - GENERAL 3. GENERAL CONTRACTOR IS TO LAYOUT WORK AND BE RESPONSIBLE FOR ALL LINES, MEASUREMENTS OF THE BUILDING, UTILITIES, AND OTHER WORK EXECUTED UNDER THE CONTRACT. 1. ALL TRADES SHALL CONFINE CONSTRUCTION WORK TO WITHIN LEASED PREMISES AS MUCH AS POSSIBLE AND SHALL WORK IN AN ORDERLY MANNER REMOVING TRASH AND DEBRIS FROM PROJECT ON A DAILY BASIS INCLUDING TRASH AND DEBRIS GENERATED BY TENANT SUPPLIED AND/OR INSTALLED ITEMS. AT NO TIME WILL PIPES, WIRES, BOARD, OR OTHER CONSTRUCTION MATERIALS CROSS PUBLIC AREAS WHERE HARM COULD BE CAUSED TO THE PUBLIC. ALL ITEMS SHALL BE INSTALLED USING STANDARD PROFESSIONAL PRACTICES USING FASTENERS, ADHESIVES AND METHODS REQUIRED BY MANUFACTURER AND INDUSTRY MANUALS. 01510 TEMPORARY UTILITIES LAYOUT OF WORK TRASH REMOVAL F. 01426 PROCEDURES 2. EXERCISE PROPER PRECAUTION TO VERIFY ALL EXISTING CONDITIONS AND LAYOUT OF CONTRACTOR TO NOTIFY TENANT OF ANY DISCREPANCIES IMMEDIATELY. CONTRACTOR IS RESPONSIBLE FOR ANY ERROR RESULTING FROM FAILURE TO EXERCISE SUCH PRECAUTION. SUCH ERROR WILL NOT BE CONSIDERED SUBSEQUENTLY AS A BASIS FOR EXTRA COMPENSATION. D. GENERAL CONTRACTOR AND/OR SUB CONTRACTOR SHALL GUARANTEE HIS WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY THE OWNER. PART 1 - GENERAL 1. IMMEDIATELY AFTER DEMOLITION, GENERAL CONTRACTOR TO ADVISE TENANT OF ANY DISCREPANCIES IN OVERALL WIDTH, LENGTH, AVAILABLE CEILING HEIGHTS, COLUMN LOCATIONS, STOREFRONT, UTILITY LOCATIONS, ETC. C. ALL WORK SHALL BE EXECUTED BY TRADESMEN AND MECHANICS QUALIFIED, THROUGH EXPERIENCE, IN THEIR RESPECTIVE TRADES. SAID CONTRACTORS SHALL REMOVE AND REPLACE WITHOUT DELAY AND WORK CONTRARY TO THE CONTRACT DOCUMENTS WHEN SPECIFICALLY DIRECTED. VERIFY THAT COMPACTED GRANULAR BASE IS IN PLACE AND READY TO SUPPORT PAVINGAND IMPOSED LOADS. 4000 Luxottica Place, Mason, OH 45040 a FR I A R DIVISION 01000 - GENERAL REQUIREMENTS 01000 GENERAL NOTES a B. INSTALLATION QUALITY ASSURANCE - DESIGN AND ANALYSIS OF STRUCTURAL PROPERTIES SHALL COMPLY WITH AISI "SPECIFICATION FOR THE DESIGN OF COLD-FORMED STRUCTURAL STEEL MEMBERS". END OF DIVISION Title SPECIFICATIONS 1 of 2 Date 07-01-16 Drawn By LLB Checked By ANP Sheet G003 A. COORDINATE THE WORK WITH OTHER DIRECTLY AFFECTED SECTIONS INVOLVING MANUFACTURE OR FABRICATION OF INTERNAL REINFORCEMENT FOR DOOR HARDWARE AND RECESSED ITEMS. B. VERIFY THAT DOORS AND FRAMES ARE READY TO RECEIVE WORK AND DIMENSIONS ARE AS INDICATED. C. INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. D. USE TEMPLATES PROVIDED BY HARDWARE ITEM MANUFACTURER. E. ADJUST HARDWARE FOR SMOOTH OPERATION. 08800 GLAZING PART 1 - GENERAL A. FURNISH AND INSTALL A COMPLETE SYSTEM OF GLASS, GLAZING CHANNELS, SEALANT, SETTING BLOCKS AND ACCESSORIES AS SHOWN AND DETAILED ON THE DRAWINGS AND RESPONSIBILITY SCHEDULE. B. SEE PLANS AND ELEVATIONS FOR SIZE AND NUMBER OF PANES. C. FOLLOW RECOMMENDATIONS FOR INSTALLATION CONTAINED IN THE FGMA (FLOAT GLASS MANUFACTURERS ASSOCIATION) GLAZING AND SEALANT MANUALS AS WELL AS SIGMA (SEALED INSULATED GLASS MANUFACTURE. ASSOCIATION) FOR INSULATED GLASS. D. E. F. 5. COVER TAPED AND FILLED JOINTS AND FILLED SCREW HEAD DEPRESSIONS WITH TOPPING COMPOUND APPLIED IN THREE COATS. PERMITTING THE PREVIOUS COAT TO DRY PRIOR TO INSTALLING THE SUBSEQUENT COAT. 6. SAND JOINT AND SCREW HEAD AREAS LIGHTLY BETWEEN COATS AND AFTER THE FINAL COAT SO THAT A SMOOTH LEVEL SURFACE IS PRODUCED WITH THE PAPER SURFACE OF THE WALLBOARD FREE OF SCUFFING. F. PATCH AND/OR REPAIR EXISTING DRYWALL TO REMAIN TO LIKE NEW CONDITION. LEVEL ANY UNEVEN OR ROUGH SPOTS AND FINISH SMOOTH. BULGES AND VISUAL DEPRESSIONS ARE NOT ACCEPTABLE. G. INSTALL CEMENTITIOUS BACKER BOARD AT ALL AREAS TO RECEIVE TILE OR MARBLE, OR AS SHOWN ON =DRAWINGS. H. ACCESS PANELS: 1. G.C. SHALL PROVIDE AND INSTALL ACCESS PANELS AS REQUIRED BY LANDLORD AND SITE CONDITIONS (COORDINATE SIZE REQUIREMENTS, NUMBER OF PANELS REQUIRED AND LOCATIONS WITH LANDLORD AND ALL MECHANICAL TRADES). IT IS THE GLAZING CONTRACTORS SOLE RESPONSIBILITY TO VERIFY THAT THE GLASS IS SIZED TO WITHSTAND DEAD LOADS, POSITIVE AND NEGATIVE LIVE LOADS, ACTING NORMAL TO PLANE OF GLASS AS CALCULATED IN ACCORDANCE WITH LOCAL AND STATE CODES. 2. ACCESS PANELS SHALL BE FLUSH TYPE (NO EXPOSED FLANGES) STYLE AS MANUFACTURED BY: INTEX FORMS INC. - GLASS FIBER (GFRG) FLUSH ACCESS PANEL 1. CLEAR GLASS - ASTM C1048, FT-FULLY TEMP., QUALITY-q3 GLAZING SELECT. 2. THICKNESS AS SHOWN ON PLAN. 3. EACH INDIVIDUAL PANE TO RECEIVE TEMPERED STAMP INDICATING SUCH. MATERIAL FOR EXTERIOR STOREFRONT IN METAL GLAZING SYSTEM. INSULATED GLASS UNITS - LOW E - TYPE SG-B - ASTM E774 AND E773 DOUBLE PANE WITH GLASS ELASTOMER EDGE SEAL; OUTER PANE OF CLEAR GLASS, INNER PANE OF LOW E CLEAR GLASS ON CLEAR COLOR GLASS. a. PROVIDE TEMPERED GLASS UNITS WHERE INDICATED ON PLAN OR AS REQUIRED BY JURISDICTIONAL CODES. PART 2 - PREPARATION / EXECUTION A. VERIFY THAT OPENINGS FOR GLAZING ARE CORRECTLY SIZED AND WITHIN TOLERANCE. VERIFY THAT SURFACES OF GLAZING CHANNELS OR RECESSES ARE CLEAN, FREE OF OBSTRUCTIONS THAT MAY IMPEDE MOISTURE MOVEMENT, WEEPS ARE CLEAR, AND READY TO RECEIVE GLAZING. (SIZE AS REQUIRED) 3. PANELS TO BE FACTORY PRIMED (WHITE) READY TO RECEIVE FINAL FINISH PAINT BY G.C. 09300 TILE AND MARBLE PART 1 - GENERAL A. MARBLE/CERAMIC/QUARRY TILE: REFER TO FINISH AND RESPONSIBILITY SCHEDULE FOR SIZES, COLORS, AND MANUFACTURERS. B. INSTALL GROUT AS RECOMMENDED BY THE TILE MANUFACTURER. COLOR OF WALL GROUT TO BE INDICATED ON THE FINISH SCHEDULE. IF NO COLOR IS INDICATED, A GROUT TO MATCH TILE IS TO BE USED. C. ALL CERAMIC TILE BASES INSTALLED SHALL BE SANITARY COVE TYPE. REFER TO FINISH SCHEDULE FOR SPECIFICATIONS. C. CUT GLASS PANES TO ACCURATE SIZES ALLOWING FOR EDGE CLEARANCES AND TOLERANCES. PART 2 - PREPARATION / EXECUTION REFER TO SECTION 03732 "CONCRETE REPAIR / PREPARATION". AND TO SECTION 07200 "INSULATION AND WATERPROOFING" D. INSTALL SEALANTS RECOMMENDED BY MANUFACTURER WHICH ARE COMPATIBLE WITH MATERIALS THEY WILL BE IN CONTACT WITH. A. E. REMOVE GLAZING MATERIALS FROM FINISH SURFACES. F. REMOVE LABELS AFTER WORK IS COMPLETE. G. CLEAN GLASS AND ADJACENT SURFACES. 08835 MIRROR B. BEFORE SETTING ANY TILE, THE CONTRACTOR SHALL ASSURE HIMSELF THAT NO TILES WILL HAVE TO BE REMOVED AFTER INSTALLATION TO ACCOMMODATE THE WORK OF OTHER TRADES. ALL CUTTING, FITTING, DRILLING AND GRINDING OF THE WORK, WHERE NECESSARY IN RELATION TO THE WORK OF OTHER TRADES, SHALL BE PERFORMED SO THAT THE WORK WILL BE NEATLY AND ACCURATELY DONE AND CUT EDGES SHALL BE UNIFORM. CONFORM TO REQUIREMENTS UNDER AMERICAN NATIONAL STANDARDS INSTITUTE ANSI A-137.1 FOR CERAMIC TILE MATERIAL AND ANSI A-108 FOR INSTALLATION. C. INSTALL PER LANDLORD'S SPECIFICATIONS, WHERE APPLICABLE. PART 1 - GENERAL A. FURNISH AND INSTALL CUSTOM FITTED MIRRORS INCLUDING MASTIC AND ATTACHMENT CLIPS AS SIZED AND DETAILED IN DRAWINGS AND RESPONSIBILITY SCHEDULE. REFER TO TOILET ROOM ACCESSORIES FOR TENANT-PROVIDED MIRRORS IN LAVATORY. VERIFY WITH TENANT'S PROJECT MANAGER. D. LAY OUT TILE PATTERN SYMMETRICALLY WITH EVEN JOINT ON ALL FLOOR AND WALL SURFACES. ALIGN JOINTS WITH MALL PATTERN, WHERE APPLICABLE. E. CUT AND DRILL TILE AS REQUIRED WITHOUT MARRING TILE, GRIND AND FIT AROUND FIXTURES, ETC.. LEAVE COMPLETED WORK FREE FROM CRACKED, BROKEN, OR DAMAGED TILE. B. CONSULT NAMM (NATIONAL ASSOCIATION OF MIRROR MANUFACTURING) FOR TIPS FOR CARE AND HANDLING OF MIRRORS. F. ALL TRANSITIONS BETWEEN NEW AND EXISTING OR UNLIKE FINISHES SHALL BE FLUSH AND SMOOTH. NO REDUCER STRIPS PERMITTED IN STOREFRONT AREA. C. PRODUCT: H. PROTECT HEAVILY TRAVELED, NEWLY TILED AREAS AS REQUIRED. I. INSTALL TILES USING THINSET METHOD WITH 1/16" JOINTS AT WALLS AND FLOORS. J. SEAL/WAX ALL TILE PER MANUFACTURER'S SPECIFICATIONS. 1. CLEAR FLOAT TYPE WITH COPPER/SILVER COATING. UNLESS NOTED OTHERWISE, ALL EDGES SHALL BE POLISHED. D. MIRROR ADHESIVE: CHEMICALLY COMPATIBLE WITH MIRROR COATING AND WALL SUBSTRATE. PART 2 - PREPARATION / EXECUTION A. VERIFY AREAS RECEIVING MIRRORS ARE WITHIN TOLERANCES AND ARE READY TO RECEIVE MATERIAL. B. PLACE PLUMB AND LEVEL WITHOUT VISIBLE DISTORTION. C. STORE, PROTECT, AND INSTALL MIRRORS IN ACCORDANCE WITH NAMM. D. SET MIRRORS WITH EDGE CLEARANCE FREE OF SURROUNDING CONSTRUCTION INCLUDING COUNTERTOPS OR BACKSPLASHES. E. REMOVE LABELS AFTER WORK IS COMPLETE. F. CLEAN MIRRORS AND ADJACENT SURFACES. END OF DIVISION 09120 CEILING SUSPENSION SYSTEMS 09650 VINYL RESILIENT TILE FLOORING PART 1 - GENERAL A. G.C. TO SUPPLY AND INSTALL 1/8" X 12" X 12" VINYL RESILIENT TILES, AS SHOWN AND SPECIFIED ON THE DRAWINGS. B. INSTALL 4" HIGH X 1/8" THICK, TOP SET, COVED VINYL BASE, AT ALL WALLS IN AREAS TO RECEIVE VINYL TILE FLOORING, AS SPECIFIED ON DRAWINGS. C. SEE FINISH SCHEDULE FOR SPECIFIC COLORS AND MANUFACTURER. C. REFER TO DRAWINGS FOR LOCATION OF SPECIFIED MATERIALS AND FINISHES. WHERE REQUIRED BY CODES, CEILING ASSEMBLIES ARE TO CONFORM WITH UNDERWRITERS LABORATORIES DESIGN FOR ONE HOUR FIRE RATED ASSEMBLIES. 09652 WOOD FLOORING E. INSTALL EDGE MOLDINGS AT PERIMETER OF ACOUSTICAL CEILING AREA AND AT LOCATIONS WHERE NECESSARY TO CONCEAL EDGES OF ACOUSTICAL UNITS. F. INSTALL ACOUSTICAL PANELS IN COORDINATION WITH SUSPENSION SYSTEM, WITH EDGES CONCEALED BY SUPPORT OF SUSPENSION ,MEMBERS, SCRIBE AND CUT PANELS TO FIT ACCURATELY AT BORDERS AND PENETRATIONS. G. INSTALL HOLD-DOWN CLIPS IF REQUIRED BY CODE. H. GWB CEILINGS AND SOFFITS TO BE GIVEN A FLAT AND SMOOTH FINISH TO ACCEPT PAINT FINISH. REFER TO SECTION 09250 "GYPSUM BOARD SYSTEMS". 09250 GYPSUM BOARD SYSTEMS LEVEL 5 GYPSUM BOARD FINISH SPECIFICATION: A. ALL JOINTS AND INTERIOR ANGLES SHALL HAVE TAPE EMBEDDED IN JOINT COMPOUND AND TWO SEPARATE COATS OF JOINT COMPOUND APPLIED OVER ALL FLAT JOINTS AND ONE SEPARATE COAT OF JOINT COMPOUND APPLIED OVER INTERIOR ANGLES. FASTENER HEADS AND ACCESSORIES SHALL BE COVERED WITH THREE SEPARATE COATS OF JOINT COMPOUND. A THIN SKIM COAT OF JOINT COMPOUND OR A MATERIAL MANUFACTURED ESPECIALLY FOR THIS PURPOSE, SHALL BE APPLIED TO THE ENTIRE SURFACE. THE SURFACE SHALL BE SMOOTH AND FREE OF TOOL MARKS AND RIDGES. NOTE: IT IS RECOMMENDED THAT THE PREPARED SURFACE BE COATED WITH A DRYWALL PRIMER PRIOR TO THE APPLICATION OF FINISH PAINT. PART 1 - GENERAL A. FINISHED WOOD FLOOR AS SPECIFIED IN FINISH AND RESPONSIBILITY SCHEDULES. INSTALLED PER MANUFACTURER'S PRINTED INSTRUCTIONS AND RECOMMENDATIONS. B. MATERIALS SHALL BE LISTED WITH UNDERWRITERS LABORATORIES AS TO FIRE AND SLIP RESISTANCE. C. ARCHITECTURAL TRIM, i.e. REDUCER STRIPS, BANDS, PICKETS, ETC., SHALL BE OF SAME MANUFACTURER AND FINISH AS WOOD FLOOR. PART 2 - PREPARATION / EXECUTION REFER TO SECTION 03732 "CONCRETE REPAIR / PREPARATION". AND TO SECTION 07200 "INSULATION AND WATERPROOFING" A. GENERAL CONTRACTOR TO BROOM CLEAN FLOORING AS IT IS INSTALLED. PROTECT FLOORING IMMEDIATELY WITH BROWN KRAFT PAPER AND INSTALL MASONITE, ORIENTED STRAND BOARD OR OTHER PROTECTIVE FLOOR PANELS OVER ENTIRE WOOD FLOOR. B. NO FLOORING TO BE EXPOSED UNTIL LAST DAY OF FIXTURING AND PROP INSTALLATION. C. FLOOR CLEAN-UP: FOLLOWING COMPLETION OF WORK BY OTHER TRADES, THE PROTECTIVE COVERING PLACED AFTER INSTALLATION SHOULD BE REMOVED; FOLLOWED BY SWEEPING, VACUUMING AND/OR DRY MOPPING TO REMOVE ALL LOOSE DEBRIS. 09680 CARPET PART 1 - GENERAL A. CONDITION CARPET AND ADHESIVES FOR AT LEAST 48 HOURS AT A MINIMUM TEMPERATURE OF 65 DEGREES FAHRENHEIT. THE FLOOR SHOULD ALSO BE CONDITIONED AT A TEMPERATURE ABOVE 65 DEGREES F FOR AT LEAST 24 HOURS PRIOR TO INSTALLATION. THE FLOOR MUST BE SWEPT FREE OF DUST AND DEBRIS. B. NEW CONCRETE MUST BE CURED PREFERABLY FOR 90 DAYS BEFORE INSTALLING CARPET. CHECK THE SLAB FOR ALKALINITY, WHICH SHOULD BE LESS THAN 9.0 pH IF NECESSARY, NEUTRALIZE THE FLOOR WITH AN ACID WASH OF 10 PARTS WATER TO ONE PART MURIATIC ACID AND RINSE THOROUGHLY. A SEALER SHOULD BE USED TO INSURE A GOOD BONDING SURFACE. EXISTING CONCRETE MAY REQUIRE RESEALING TO ASSURE A PROPER SURFACE. C. REMOVE, REPLACE OR PATCH OLD VINYL TILE OR LINOLEUM, STRIP OLD WAX BY MOPPING WITH AMMONIA AND WATER, AND FILL IN GROUT LINES ON CERAMIC FLOORS WITH A LATEX FLASHING COMPOUND, AS APPLICABLE. D. REMOVE ANY FINISHES, WAXES, PAINT, ETC. FROM WOOD FLOORS. THE SURFACE MUST BE LEVEL AND CRACKS MAY REQUIRE A FLASHING COMPOUND. PLYWOOD OR PARTICLE BOARD MAY BE NECESSARY TO OFFSET UNEVEN FLOORS, BUT MUST BE PRIMED PRIOR TO INSTALLATION. PART 1 - GENERAL A. FURNISH AND INSTALL ALL GYPSUM DRYWALL AND SYSTEMS COMPLETE WITH PARTITION FRAMING, CEILING SUSPENSION SYSTEMS AND RELATED ACCESSORIES, PARTS, MATERIALS, ETC. AS SHOWN ON DRAWINGS AND AS SPECIFIED. INSTALL ALL MATERIALS PER MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS. E. CUT-BACK ADHESIVE MUST BE FLASHED OVER. USING A NOTCHED TROWEL, PATCH AND LET CURE. SMOOTH OVER WITH A SECOND COAT OF PATCH, USING THE FLAT SIDE OF THE TROWEL TO FILL IN THE RIDGES. ALLOW THE NEWLY FLASHED FLOOR TO CURE. B. GYPSUM DRYWALL: ALL GYPSUM BOARD TO BE 5/8" TYPE "X" AS NOTED ON NEW CONSTRUCTION PLAN. REST ROOMS TO RECEIVE MOISTURE RESISTANT GYPSUM BOARD. F. C. FASTENERS: DRYWALL SCREWS OF PROPER SIZE AND TYPE PER MANUFACTURERS RECOMMENDATIONS. CARPET CONTRACTOR TO ESTABLISH HIS OWN TAKEOFFS AND COORDINATE HIS TAKEOFFS WITH THE AMOUNT SHIPPED BY TENANT AND CONTACT THE CONSTRUCTION COORDINATOR OF ANY DISCREPANCIES. D. PROVIDE MATERIALS, JOINT COMPOUNDS, TRIM, EDGES, BEADS, ETC. FROM A SINGLE SOURCE SUPPLIER. ALL TRIM SHALL CONSIST OF A TAPERED, GROOVED, AND PREPUNCHED FIN FOR SCREW ATTACHMENT AND TO ACCEPT BONDING AGENT. ALL BUTT JOINTS ARE TO BE NEAT WITH TIGHT JOINTS, AND ALL CORNERS ARE TO BE MITERED. ALL EDGES, BEADS AND TRIM TO BE PRE-FINISH ALUMINUM. G. INSTALL PER FLOOR AND WALL FINISH PLAN AND PROVIDE TENANT WITH SEAM LAYOUT PRIOR TO CUTTING / INSTALLATION. H. FILL ALL CRACKS, JOINTS, ETC. IN SUB-FLOOR WITH CRACK FILLER APPROVED BY CARPET MANUFACTURER. E. H. JOINT TREATMENT: U.S. GYPSUM OR GOLD BOND SYSTEM OF COMPOUNDS AND PERFORATED TAPE. 1. ERECT GWB IN A SINGLE LAYER IN THE MOST ECONOMICAL DIRECTION WITH ENDS AND EDGES OCCURRING OVER FIRM BEARING. 2. WALLS, CEILINGS AND SOFFITS, AND ALL TRANSITIONS IN SAME, SHALL BE GIVEN A SMOOTH FINISH. 3. CORNER BEADS SHALL BE APPLIED TO ALL EXTERNAL ANGLES IN STRICT ACCORDANCE WITH THE MANUFACTURERS DIRECTIONS. INSTALL CASING BEADS AT ALL EDGES OF DRYWALL WORK EXCEPT WHERE TERMINATION IS COVERED BY OTHER FINISH. CASING BEADS SHALL BE MITERED AT CORNERS AND INSTALLED NEATLY, FINISHED WITH COMPOUND. INSTALL "WHISPERWALK". E. INSTALL LAMINATE FLOORING AS A "FLOATING" FLOOR. BEGIN INSTALLATION ALONG WALL WITH TONGUE FACING WALL ACCORDING TO MANUFACTURER'S PROCEDURES. APPLY GLUE TO GROOVES WITH PLANKS IN PLACE ON FLOOR. ENSURE JOINTS ARE COMPLETELY SEALED WITH GLUE. DO NOT NAIL, SCREW OR FASTEN FLOORING TO SUBFLOOR. F. PROVIDE ADEQUATE EXPANSION SPACE AT PERIMETER, COLUMNS, AND AT ALL ALL OTHER OBSTRUCTIONS. G. INSTALL SPECIFIED BASE OR TRIM AT PERIMETER, COLUMNS, AND AT ALL OTHER OBSTRUCTIONS. H. NO FLOORING TO BE EXPOSED UNTIL LAST DAY OF FIXTURING AND MERCHANDISE INSTALLATION. I. FLOOR CLEANUP: FOLLOWING COMPLETION OF WORK BY OTHER TRADES, THE PROTECTIVE COVERING PLACED AFTER INSTALLATION SHOULD BE REMOVED; FOLLOWED BY SWEEPING, VACUUMING AND/OR DRY MOPPING TO REMOVE ALL LOOSE DEBRIS. PROVIDE DIRECT GLUEDOWN INSTALLATION USING MATERIAL AND METHODS RECOMMENDED BY CARPET MANUFACTURER. SEAL ALL SEAMS WITH SEAM ADHESIVE. 09700 LAMINATED WOOD FLOORING p +1 (513) 765-6000 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Macy's Store Number: (687) Revisions: Mark B. 1 PREP FLOOR AS RECOMMENDED BY THE MANUFACTURER. C. INSTALL COMPLETE PER MANUFACTURER'S SPECIFICATIONS, INCLUDING ALL TRANSITION STRIPS AND EXPANSION JOINTS AS REQUIRED FOR PROPER INSTALLATION. By 07/07/16 Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS USE ONLY THE PAINT AND RELATED MATERIALS SPECIFIED BY THE MANUFACTURER. SEE FINISH SCHEDULE FOR SPECIFIC COLORS. ALTERNATES ARE NOT PERMITTED. PART 2 - PREPARATION / EXECUTION A. CLEAN ALL SURFACES TO BE PAINTED FREE OF LOOSE DIRT AND DUST BEFORE WORK IS STARTED. WASH ALL METAL SURFACES WITH MINERAL SPIRITS BEFORE APPLYING FINISHES. WHERE RUST OR SCALE IS PRESENT, WIRE BRUSH OR SAND CLEAN BEFORE APPLYING FINISH. B. PAINTED DRYWALL TO RECEIVE ONE COAT LATEX PRIMER AND TWO COATS OF SPECIFIED PAINT. TINT PRIMER TO APPROXIMATE SHADE OF THE FINAL COAT. TOUCHUP ALL SUCTION SPOTS OR HOT SPOTS AFTER APPLICATION OF FIRST COAT AND BEFORE APPLYING SECOND COAT, TO PRODUCE AND EVEN RESULT IN THE FINISH COAT. DRY ALL COATS THOROUGHLY BEFORE APPLYING SUCCEEDING COATS. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR RECOAT TIME. SEAL ALL DRYWALL SURFACES BEHIND MIRRORS. C. PUTTY ALL NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE APPLYING FINISH. D. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. E. BEFORE STARTING FINISH WORK, REMOVE HARDWARE, ACCESSORIES, PLATES, LIGHTING FIXTURES AND SIMILAR ITEMS, OR PROVIDE AMPLE PROTECTION FOR SUCH ITEMS. F. PAINT ALL EXPOSED PIPING, ACCESS DOORS, VENTS, FIRE EXTINGUISHER CABINETS, EQUIPMENT MOUNTING BOARDS, ETC. TO MATCH ADJACENT WORK UNLESS OTHERWISE NOTED OR DIRECTED. G. SAND ENAMELED FINISHES APPLIED TO WOOD OR METAL BETWEEN COATS WITH FINE SANDPAPER TO PRODUCE EVEN SMOOTH FINISH. H. MAKE FINISH WORK UNIFORM, SMOOTH, FREE OF RUNS, SAGS AND DEFECTIVE BRUSHING OR SPRAYING. MAKE EDGES ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING. I. SEAL TOPS, BOTTOMS AND EDGES OF ALL DOORS. J. K. Architect of Record CONTRACTOR TO LEAVE ONE QUART EACH COLOR OF PAINT FOR FUTURE TOUCH-UP. ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 2016-026A Seal PRIOR TO CONTRACTOR LEAVING SITE AND AFTER ALL FIXTURES ARE INSTALLED AND STORE IS CLEANED, CONTRACTOR TO WALK SITE AND TOUCH-UP PAINT DAMAGED DURING FINAL DAYS OF PROJECT. END OF DIVISION DIVISION 10000 - SPECIALTIES 10520 FIRE PROTECTION PART 1 - GENERAL A. PROVIDE MULTI-PURPOSE CHEMICAL FIRE EXTINGUISHERS CAPABLE OF EXTINGUISHING CLASS A, B, AND C FIRES, IN QUANTITIES AND LOCATIONS REQUIRED BY LOCAL FIRE MARSHALL. (COORDINATE IN FIELD.) MANUFACTURER: J.L. INDUSTRIES; COSMIC SERIES OR EQUAL. 10800 TOILET ROOM ACCESSORIES NAME: GLENN S. YEAKEL DATE: 07-01-16 REG NO: 20474 Engineer PART 1 - GENERAL A. TENANT TO SUPPLY A.D.A. APPROVED TOILET ACCESSORIES AND GRAB BARS INCLUDING ALL SET SCREWS AND ANCHORS REQUIRED FOR COMPLETE INSTALLATION. PART 2 - PREPARATION / EXECUTION A. G.C. SHALL INSTALL TOILET ACCESSORY UNITS ACCORDING TO MANUFACTURER'S INSTRUCTIONS, USING FASTENERS AND IN WALL BLOCKING AS RECOMMENDED BY UNIT MANUFACTURER. INSTALL UNITS PLUMB AND LEVEL, FIRMLY ANCHORED IN LOCATIONS AND AT HEIGHTS INDICATED, IN A TAMPERPROOF MANNER WITH SPECIAL HANGERS, TOGGLE BOLTS, OR SCREWS. END OF DIVISION 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 DIVISION 11000 - EQUIPMENT 11001 EQUIPMENT PART 1 - GENERAL A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT WORK AND PLACEMENT WITH THE WORK OF ALL OTHER TRADES AND MAKE ADJUSTMENTS AS REQUIRED TO ACCOMMODATE LOCATIONS OF EQUIPMENT. B. ALL EQUIPMENT WORK SHALL COMPLY WITH ALL GOVERNING BUILDING CODES AND LOCAL C. EQUIPMENT SHALL BE FURNISHED, UNLOADED, UNPACKED OR UNCRATED AND PLACED ACCORDING TO THE CONSTRUCTION DOCUMENTS. Seal PART 2 - PREPARATION / EXECUTION A. GENERAL CONTRACTOR'S INSTALLATION OF TENANT SUPPLIED EQUIPMENT IS TO BE INCLUDED IN GENERAL BID. B. GENERAL CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER IMMEDIATELY OF ANYDAMAGE TO THE EQUIPMENT PRIOR TO INSTALLATION. C. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL HOOKUP OF ALL EQUIPMENT, INCLUDING ALL MECHANICAL, PLUMBING AND ELECTRICAL WORK. D. ALL EQUIPMENT MANUALS, INSTRUCTION BOOKLETS AND WARRANTY INFORMATION SHALL BE NEATLY BOUND AND TURNED OVER TO THE CONSTRUCTION MANAGER PRIOR TO THE TURNOVER. E. STEAM PRESS SUPPLIED BY TENANT SHALL BE INSTALLED BY G.C.'S CERTIFIED STEAM FITTER/PLUMBER FOR FINAL CONNECTIONS. 11110 MISCELLANEOUS PART 1 - GENERAL A. GENERAL CONTRACTOR TO INSTALL TRAFFIC COUNTING SYSTEM PER MANUFACTURER'S SPECIFICATIONS. 1. THE SYSTEM'S TRANSMITTER AND REFLECTOR ARE TO BE INSTALLED AT EACH PUBLIC ENTRANCE, 52" A.F.F., AS INDICATED IN DRAWINGS. DOOR SWING NOR ANY OTHER OBSTRUCTION SHOULD BLOCK THE "BEAM" PATH. 2. THE SYSTEM'S RECEIVER IS TO BE INSTALLED IN CASH-DESK CABINETRY. B. GENERAL CONTRACTOR TO INSTALL FULL HEIGHT, WHITE CORNER GUARDS WITH WHITE ADHESIVE WHERE INDICATED ON DRAWINGS. END OF DIVISION NAME: DATE: REG NO: Nextore project Number 73052 ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title PART 1 - GENERAL A. WOOD LAMINATE FLOORING: REFER TO FINISH AND RESPONSIBILITY SCHEDULE FOR SIZES, COLORS, AND MANUFACTURERS. B. Date 09910 PAINTING AND FINISHING PART 1 - GENERAL A. THE INTENT IS TO PROVIDE A SATISFACTORY FINISH TO ALL PARTS OF THIS PROJECT. FINISH APPEARANCE MUST BE UNIFORM, SMOOTH, AND FREE OF ANY RUNS, SAGS, AND DEFECTIVE BRUSHING OR SPRAYING. COVER ALL SURFACES THOROUGHLY IF THE NUMBER OF COATS RECOMMENDED BY MANUFACTURER DOES NOT ACCOMPLISH THE INTENT, THEN APPLY ADDITIONAL COATS UNTIL COVERAGE IS SATISFACTORY. SEE FINISH SCHEDULE FOR PAINT COLORS, MANUFACTURER, ETC. ALL SALES AREAS AND PUBLIC AREAS TO HAVE RECESSED BRASS CABINETS PROVIDED AND INSTALLED BY G.C. SLOPE FLOOR TILE TO DRAINS. SUBSTRATE MUST ALSO BE SLOPED TO DRAIN. INSTALL SUSPENSION SYSTEM TO COMPLY WITH ASTM C 636, WITH HANGERS SUPPORTED ONLY FROM BUILDING STRUCTURAL MEMBERS. LOCATE HANGERS NOT LESS THAN 6" FROM EACH END AND SPACE 4'-0" ALONG EACH CARRYING CHANNEL OR DIRECT-HUNG RUNNER. SECURE WIRE HANGERS BY LOOPING AND WIRE TYING, EITHER DIRECTLY TO STRUCTURES OR TO INSERTS, EYE-SCREWS, OR OTHER DEVICES WHICH ARE SECURE AND APPROPRIATE FOR SUBSTRATE. D. C. ALL VCT SHALL BE CLEANED, SEALED, AND WAXED BY G.C. PRIOR TO TURNOVER. D. INSTALL POLYETHYLENE FILM ON CONCRETE SUBFLOOR. SECURE MOUNTING BRACKETS TO STRUCTURE, SQUARE AND PLUMB, TO COMPLY WITH MANUFACTURER'S INSTRUCTIONS. C. COMPLY WITH MANUFACTURER'S PRINTED INSTRUCTIONS AND WITH GOVERNING REGULATIONS, FIRE-RESISTANCE RATING REQUIREMENT AND WITH INDUSTRY STANDARDS APPLICABLE TO THE WORK. PREPARE SUBFLOOR OR EXISTING FLOOR SYSTEM AS RECOMMENDED BY MANUFACTURER. C. B. FILL ALL CRACKS, JOINTS, ETC. IN SUB-FLOOR WITH CRACK FILLER APPROVED BY FLOORING MANUFACTURER. INSTALL ALL MATERIALS WITH WATERPROOF TYPE ADHESIVES AS RECOMMENDED BY FLOORING MANUFACTURER FOR MATERIALS AND SURFACES INVOLVED. D. C. B. B. SUSPENSION SYSTEM AND ACOUSTIC PANELS AS LISTED ON REFLECTED CEILING PLAN SHEET AND RESPONSIBILITY SCHEDULE. COMPLY WITH ASTM C 635 FOR INTERMEDIATE - DUTY CLASS SYSTEM. SIZE ATTACHMENT DEVICES FOR FIVE (5) TIMES DESIGN LOAD. HANGER WIRE SHALL BE GALVANIZED CARBON STEEL, ASTM A641, SOFT TEMPER, PRE-STRETCHED, 12 GA MINIMUM. GENERAL CONTRACTOR TO RECEIVE AND STORE MATERIAL. G.C. MUST OPEN BOXES A MINIMUM OF 48 HOURS IN ADVANCE OF INSTALLATION TO ACCLIMATE PRODUCT TO TEMPERATURE AND HUMIDITY OF AREA TO RECEIVE INSTALLATION. PART 2 - PREPARATION / EXECUTION A. INSTALL MOUNTING BRACKETS AT HEIGHTS TO COMPLY WITH APPLICABLE REGULATIONS OF GOVERNIN AUTHORITIES. B. B. A. PART 2 - PREPARATION / EXECUTION REFER TO SECTION 03732 "CONCRETE REPAIR / PREPARATION". AND TO SECTION 07200 "INSULATION AND WATERPROOFING" A. PREP SLAB AS REQUIRED TO RECEIVE NEW VINYL TILE. PART 1 - GENERAL A. PROVIDE ACOUSTICAL PANEL CEILINGS WITH EXPOSED SUSPENSION GRID, AS SHOWN ON THE DRAWINGS. PART 2 - PREPARATION / EXECUTION A. AT TIME OF COMPLETION, DELIVER TWO PACKAGES OF ACOUSTICAL PANELS TO THE TENANT OF EACH TYPE OF MATERIAL USED, FOR FUTURE REPLACEMENT USE. PART 2 - PREPARATION / EXECUTION REFER TO SECTION 03732 "CONCRETE REPAIR / PREPARATION". AND TO SECTION 07200 "INSULATION AND WATERPROOFING" PHONE NUMBER: 650-654-7855 MATERIAL FOR INTERIOR STOREFRONT GLASS: 1. B. 4. JOINTS BETWEEN BOARDS SHALL BE REINFORCED WITH TAPE EXCEPT WHERE CONTROL JOINTS ARE REQUIRED. TAPE FIELD JOINTS, INTERIOR CORNER JOINTS AND WALL TO CEILING JOINTS. FILL JOINTS WITH JOINT FILLING COMPOUND AND EMBED TAPE THEREIN. COVER TAPE WITH BEDDING COMPOUND AND TAPER TO FEATHER EDGES. FILL SCREW HEAD DEPRESSIONS WITH JOINT FILLING COMPOUND AND FEATHER THE EDGES. ALLOW TO DRY. 4000 Luxottica Place, Mason, OH 45040 a FR I A R PART 2 - PREPARATION / EXECUTION a SPECIFICATIONS 2 of 2 Date 07-01-16 Drawn By LLB Checked By ANP Sheet G004 AREAS OF WORK a 4000 Luxottica Place, Mason, OH 45040 p +1 (513) 765-6000 a 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Macy's Store Number: (687) Revisions: Mark Date 1 By 07/07/16 Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS FR I A R Architect of Record ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 2016-026A Seal NAME: GLENN S. YEAKEL DATE: 07-01-16 REG NO: 20474 Engineer 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Seal NAME: DATE: REG NO: Nextore project Number 1. 2. "AREA OF WORK" SHOWN FOR REFERENCE ONLY; REFER TO CONSTRUCTION PLANS FOR LEASE LINE AND LIMITS OF WORK ISSUED FOR: THIS PLAN MAY NOT REFLECT ACCURATE EXISTING CONDITIONS; REFER TO CONSTRUCTION PLANS FOR EXISTING CONDITIONS Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title NORTH 1 73052 EXISTING MACY'S 1ST FLOOR PLAN MACY'S EXISTING 1ST FLOOR PLAN SCALE: 1/4" = 1'-0" Date 07-01-16 Drawn By LLB Checked By ANP Sheet V100 a 4000 Luxottica Place, Mason, OH 45040 p +1 (513) 765-6000 a 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Macy's Store Number: (687) Revisions: Mark Date 1 By 07/07/16 Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS TING 06 (E) RETAIL (E) 2 14'-8" 6" 4 EXISTING TILE FLOORING TO REMAIN EXISTING CARPET TO BE DEMOLISHED EXISTING CARPET TO BE DEMOLISHED 8 EXISTING TILE FLOORING TO REMAIN 13 17'-4" 15 (E) ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 2 (E) (E) 2016-026A (E) Seal (E) (E) (E) (E) (E) (E) 12 2 EX/D1 12 2 1 (E) S (E) (E) EXISTING CARPET TO BE DEMOLISHED (E) (E) 3 101 Architect of Record (E) 14 9 RETAIL (E) 12 (E) (E) (E) (E) 11 (E) (E) (E) (E) (E) 11 7 13 (E) (E) (E) 10 9 (E) 15 (E) (E) 13 14 (E) ) (E) (R) (E) (R) (E) (E) (E) (E) (E) 101 (E) (E) FR I A R 5 6 2 EXISTING EGRESS TO BE MAINTAINED THROUGHOUT CONSTRUCTION 7 6 (R) (E) EXISTING EGRESS TO BE MAINTAINED THROUGHOUT CONSTRUCTION 6 ALIGN 2 (D) 12 1 2 NAME: GLENN S. YEAKEL DATE: 07-01-16 REG NO: 20474 2 EXISTING TILE FLOORING TO REMAIN (E) 9 (E) AREA C AREA B Engineer 12'-8" NOTE: MACY'S RESPONSIBLE FOR REMOVING MACY'S FIXTURES & MERCHANDISE, TYP. 1 DEMOLITION - FLOOR PLAN: AREA A NORTH 2 SCALE: 1/4" = 1'-0" NORTH DEMOLITION - CEILING PLAN: AREA A AREA A 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 KEYPLAN SCALE: 1/4" = 1'-0" Seal KEY NOTES 1 1. LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF CONSTRUCTION 2. NOT IN CONTRACT; NO WORK IN THIS AREA, U.O.N. 3. TEMPORARY BARRICADE TO BE PROVIDED BY G.C. PRIOR TO START OF ANY WORK; BARRICADE SHALL NOT IMPEDE CLEAR PATH OF EGRESS IN ANY WAY, AND SHALL REMAIN INTACT THROUGHOUT DURATION OF WORK; UPON REMOVAL OF BARRICADE, G.C. TO PATCH, REPAIR AND RE-FINISH ANY DAMAGE CAUSED BY BARRICADE ATTACHMENT TO CEILING, FLOOR OR ADJACENT WALLS; REF: BARRICADE DETAIL, AD100 4. MACY'S RESPONSIBLE FOR REMOVING ALL FIXTURES, MERCHANDISE, GRAPHICS, ARTWORK AND ANY ASSOCIATED HARDWARE, WITHIN WORK AREA, U.O.N.; COORDINATE WITH MACY'S. 5. EXISTING COLUMN WITH MIRROR FINISH TO REMAIN; PROTECT DURING CONSTRUCTION 6. EXISTING WALL DISPLAY PANEL, STANDARDS AND WALL BASE TO BE REMOVED 7. 8. 1 9. GENERAL NOTES # EXISTING MILLWORK DISPLAY SURROUND TO REMAIN; PROTECT DURING CONSTRUCTION; CLEAN SURFACE A. B. C. EXISTING P.O.S. FIXTURE TO BE REMOVED; COORDINATE REMOVAL AND RELOCATION OR DEMOLITION WITH MACY'S; REMOVE ALL ASSOCIATED POWER/DATA BACK TO THE SOURCE EXISTING MACY'S FLOOR TILE TO REMAIN, TYP. 10. EXISTING CARPET TO BE REMOVED TO THE EXTENT SHOWN ON DEMOLITION PLAN; FLOOR SURFACE SHALL BE MADE LEVEL AND SMOOTH AND PREPARED TO RECEIVE NEW FLOOR FINISH PER MANUFACTURER'S INSTALLATION RECOMMENDATIONS; REF: FINISH PLAN AND FINISH SCHEDULE D. E. 11. SEE MEP DRAWINGS FOR ADDITIONAL SCOPE OF MEP DEMOLITION THROUGHOUT THIS SPACE, TYP. 12. EXISTING GWB CEILING AND ACT SYSTEM TO REMAIN; ALL ASSOCIATED CEILING FIXTURES TO REMAIN U.O.N.; REF: MEP DRAWINGS 13. EXISTING MILLWORK DISPLAY SURROUND, SOFFIT AND FASCIA TO REMAIN; PROTECT DURING CONSTRUCTION AND INSTALLATION OF FIXTURES; CLEAN ALL SURFACES PRIOR TO INSTALLATION OF FIXTURES 14. EXISTING SOFFIT LIGHT FIXTURES AND LENSES TO REMAIN; LIGHT BULBS TO BE REMOVED AND RETURNED TO MACY'S AND LENSES RE-INSTALLED. 15. SPRINKLERS THIS AREA SHALL BE RELOCATED, AND SUPPLEMENTED AS REQUIRED, TO MEET SPRINKLER REQUIREMENTS; REF: SPRINKLER SYSTEM NOTES, SHEET A-102 AND MEP DRAWINGS FOR FURTHER INFORMATION F. G. H. THE G.C. SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE PUBLIC AND/OR WORKMEN ON THE JOB AND TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON ON, ABOUT, OR ADJACENT TO THE PREMISES. THE G.C. SHALL COMPLY WITH ALL LAWS, ORDINANCES, CODES, RULES AND REGULATIONS RELATIVE TO SAFETY AND THE PREVENTION OF ACCIDENTS. THIS DEMOLITION PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET OF WORKING DRAWINGS. DO NOT REMOVE OR DEMOLISH ANYTHING WITHOUT VERIFYING AND COORDINATING WITH ALL TRADES AS TO HOW THEY RELATE TO THE OVERALL PROJECT. THE G.C. SHALL BE RESPONSIBLE FOR REMOVING OR DEMOLISHING EXISTING CONSTRUCTION WHICH WILL INTERFERE WITH THEIR NEW WORK AND ANY TEMPORARY BRACING OR PERMANENT SUPPORT STRUCTURES. WHEN EXISTING ELECTRICAL SERVICE, POWER, AND LIGHTING IS REMOVED, STUB BACK AND CAP AS REQUIRED IN AREAS BETWEEN EXISTING CONDITIONS AND NEW WORK. REMOVE EXISTING FLOORING MATERIAL, CAP EXISTING MECHANICAL, PLUMBING AND ELECTRICAL SERVICES FLUSH WITH EXISTING SLAB AS REQUIRED, TYPICAL THROUGHOUT; REFER TO RESPONSIBILITY SCHEDULE ON SHEET G002 FOR FLOORING PREPARATION. AT THE G.C.'S OPTION, DEMOLISH OR REMOVE MORE OR LESS EXISTING WORK, PROVIDED THAT SUCH VARIATION WILL EXPEDITE THE PROJECT AND NOT INCREASE THE EXPENSE TO THE OWNER OR VIOLATE ANY CODES. THESE OPTIONS SHALL BE SUBJECT TO THE LUXOTTICA'S PROJECT MANAGER'S APPROVAL. COORDINATE ANY SYSTEMS SHUTDOWNS WITH LANDLORD & INCLUDE COSTS OF SHUTDOWN IN THE BID. EXCEPT AS NOTED, G.C. SHALL INCLUDE COSTS TO CUT, PATCH AND/OR REPAIR EXISTING WORK AND EXISTING FACILITIES WHICH MAY BE DISTURBED DURING INSTALLATION OF NEW WORK IN BID PACKAGES. I. J. IN ACCORDANCE WITH THE DRAWINGS, THOSE ITEMS WHICH ARE REMOVED, AND ARE NOT RELOCATED OR REUSED, SHALL BE DISPOSED OF BY THE G.C.; VERIFY WITH MACY'S PRIOR TO DISPOSAL OF ANY DISPLAY FIXTURES, ARTWORK, OR ASSOCIATED HARDWARE. ANY EXISTING RECEPTACLES TO REMAIN UNLESS NOTED OTHERWISE ON PLANS; REFER TO ELECTRICAL DRAWINGS. L. REMOVE ALL WALL VINYL FROM WALLS (AS REQUIRED) AND PREP WALLS FOR NEW FINISHES. N. 86" G.C. TO INSPECT ALL EXISTING WALLS TO REMAIN AND ENSURE THAT THEY ARE UP TO CURRENT SPECIFICATIONS. REMOVE WINDOW CRASH GRAPHICS WALL RECEPTACLE (@ 18"AFF U.O.N.) TELEPHONE ANY EXISTING DOORS AND FRAMES TO BE REMOVED UNLESS NOTED OTHERWISE ON PLANS; REFER TO DOOR SCHEDULE. K. M. SYMBOL LEGEND FLOOR RECEPTACLE TRACK LIGHTING RECESSED LIGHT S (D) FIXTURE TO BE DEMOLISHED DIRECTIONAL LIGHT SPRINKLER HEAD FIXTURE TO BE RELOCATED SECURITY CAMERA ILLUMINATED EXIT SIGN P. NOT USED Q. SIGN CONTRACTOR SHALL REMOVE ALL SIGNAGE IN OLD (OR TEMPORARY) SPACE AT END OF PROJECT, AS REQUIRED BY LEASE REQUIREMENT. R. NOT USED S. REMOVE ALL INTERIOR GRAPHICS AND WAYFINDING, TYPICAL IN ALL AREAS (RETAIL, EMPLOYEE, OD). DO NOT REMOVE FROM LENS PROCESSING AREA. TEMPORARY BARRICADE WALL PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEET, AND ARE IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT LUXOTTICA PROJECT MANAGER PRIOR TO INSTALLATION. EXISTING ITEM TO REMAIN DATE: REG NO: ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title GRAPHIC LEGEND DEMOLITION FLOOR & CEILING PLANS: AREA A LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF WORK EXISTING ITEM TO BE DEMOLISHED 73052 SPEAKER (E) (R) B.O. CEILING VERIFY IN FIELD NAME: Nextore project Number EXISTING FIXTURE TO REMAIN G.C. TO PROVIDE AND INSTALL TEMPORARY BARRICADE. REF THIS DRAWING FOR INFORMATION ZIPWALL FOAMRAIL SPAN @ CEILING & WALLS SUPPLY AIR DIFFUSER FLUORESCENT STRIP LIGHT O. T. RETURN AIR GRILLE 2 x 2 LIGHT FIXTURE ZIPWALL DUST BARRIER SYSTEM PROVIDED AND INSTALLED BY G.C. G.C. TO VERIFY WITH SITE LOCATION STORE OPERATIONS MATERIAL TO BE USED. EITHER CLEAR PLASTIC OR TARP (FIRE RETARDANT). VERIFY CEILING FOR POLE SIZE REQUIRED. Date Sheet Drawn By ZIPWALL GRIPDISKS LLB BARRICADE DETAIL N.T.S. 07-01-16 Checked By REV 0.4 ANP AD100A a 4000 Luxottica Place, Mason, OH 45040 p +1 (513) 765-6000 a 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Macy's Store Number: (687) Revisions: Mark Date 1 By 07/07/16 Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS EXTG VESTIBULE N.I.C. EXTG STAIRS EXTG MECH 17 N.I.C. N.I.C. 4 7 10 (D) EXTG MECH EXTG STAIRS N.I.C. N.I.C. Architect of Record 2 EXTG ELEV LOBBY (R) N.I.C. 11 12 13 18 2 FR I A R 14 6" 13 C 15 16 1 1 ASSOCIATES INC. 6 3 281 Farmington Avenue Farmington, CT. 06032 6 2016-026A EQ 2 2 (D) (E) Seal (D) 5 4'-3" 4'-7" (D) (E) 1 2 9 DEMOLITION - FLOOR PLAN: AREA C SCALE: 1/4" = 1'-0" 2 (R) 2 3 1 NORTH 2 NAME: GLENN S. YEAKEL DATE: 07-01-16 REG NO: 20474 (E) (E) EXTG SALES AREA EXTG SALES AREA N.I.C. N.I.C. Engineer NOTE: MACY'S RESPONSIBLE FOR REMOVING MACY'S FIXTURES & MERCHANDISE, TYP. AREA C AREA B 1 DEMOLITION - FLOOR PLAN: AREA B NORTH 2 SCALE: 1/4" = 1'-0" DEMOLITION - CEILING PLAN: AREA B NORTH SCALE: 1/4" = 1'-0" 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 AREA A KEYPLAN KEY NOTES GENERAL NOTES # 1. LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF CONSTRUCTION 2. NOT IN CONTRACT; NO WORK IN THIS AREA, U.O.N. 3. TEMPORARY BARRICADE TO BE PROVIDED BY G.C. PRIOR TO START OF ANY WORK; BARRICADE SHALL REMAIN INTACT THROUGHOUT DURATION OF WORK; UPON REMOVAL OF BARRICADE, G.C. TO PATCH, REPAIR AND RE-FINISH ANY DAMAGE CAUSED BY BARRICADE ATTACHMENT TO CEILING, FLOOR OR ADJACENT WALLS; REF: BARRICADE DETAIL, AD100 4. MACY'S RESPONSIBLE FOR REMOVING ALL FIXTURES, MERCHANDISE, GRAPHICS, ARTWORK AND ANY ASSOCIATED HARDWARE, WITHIN WORK AREA, U.O.N.; COORDINATE WITH MACY'S. 5. LINE OF NEW WALL CONSTRUCTION; COORDINATE LOCATION OF TEMPORARY BARRICADE WALL WITH NEW WALL CONSTRUCTION 6. EXISTING WALL TO BE REMOVED IN ITS ENTIRETY, INCLUDING ALL ASSOCIATED STUDS, TRACKS, FINISHES AND RECEPTACLES; PATCH AND REPAIR WHERE DEMOLISHED WALL MEETS EXISTING WALL TO REMAIN; MAKE SMOOTH, CONTINUOUS SURFACE; REMOVE ABANDONED RECEPTACLES, CIRCUITRY AND ALL ASSOCIATED WIRING AND CONDUIT BACK TO SOURCE, TYP. U.O.N. 7. CLEAN AND PREPARE ALL WALL SURFACES TO RECEIVE NEW FINISH PER MANUFACTURER'S RECOMMENDATIONS, TYP. 8. NOT USED 9. EXISTING CARPET FLOORING TO REMAIN; PROTECT DURING DEMOLITION AND CONSTRUCTION 10. NEW STOREFRONT SYSTEM TO BE LOCATED WITHIN EXISTING WINDOW OPENING IN THE MASONRY WALL; DEMOLISH EXISTING WINDOW, DEMOLISH MASONRY SILL AND PREPARE OPENING TO RECEIVE NEW STOREFRONT SYSTEM; PROVIDE TEMPORARY SHORING AND/OR BRACING OF EXISTING WALL AS REQUIRED A. B. C. D. E. 11. EXISTING CLEAN-OUT LOCATED IN FLOOR SLAB, TO REMAIN 12. PREPARE EXISTING CONCRETE FLOOR TO RECEIVE NEW FLOOR FINISH; ENSURE SURFACE IS LEVEL AND SMOOTH; PREPARE TO RECEIVE NEW FLOOR FINISH PER MANUFACTURER'S INSTALLATION RECOMMENDATIONS; REF: FINISH PLAN AND FINISH SCHEDULE F. 13. SEE MEP DRAWINGS FOR ADDITIONAL SCOPE OF MEP DEMOLITION THROUGHOUT THIS SPACE, TYP. 14. EXISTING FLUSH WALL PIPE PENETRATION, THIS AREA; MAINTAIN ACCESS THE G.C. SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE PUBLIC AND/OR WORKMEN ON THE JOB AND TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON ON, ABOUT, OR ADJACENT TO THE PREMISES. THE G.C. SHALL COMPLY WITH ALL LAWS, ORDINANCES, CODES, RULES AND REGULATIONS RELATIVE TO SAFETY AND THE PREVENTION OF ACCIDENTS. THIS DEMOLITION PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET OF WORKING DRAWINGS. DO NOT REMOVE OR DEMOLISH ANYTHING WITHOUT VERIFYING AND COORDINATING WITH ALL TRADES AS TO HOW THEY RELATE TO THE OVERALL PROJECT. THE G.C. SHALL BE RESPONSIBLE FOR REMOVING OR DEMOLISHING EXISTING CONSTRUCTION WHICH WILL INTERFERE WITH THEIR NEW WORK AND ANY TEMPORARY BRACING OR PERMANENT SUPPORT STRUCTURES. WHEN EXISTING ELECTRICAL SERVICE, POWER, AND LIGHTING IS REMOVED, STUB BACK AND CAP AS REQUIRED IN AREAS BETWEEN EXISTING CONDITIONS AND NEW WORK. REMOVE EXISTING FLOORING MATERIAL, CAP EXISTING MECHANICAL, PLUMBING AND ELECTRICAL SERVICES FLUSH WITH EXISTING SLAB AS REQUIRED, TYPICAL THROUGHOUT; REFER TO RESPONSIBILITY SCHEDULE ON SHEET G002 FOR FLOORING PREPARATION. AT THE G.C.'S OPTION, DEMOLISH OR REMOVE MORE OR LESS EXISTING WORK, PROVIDED THAT SUCH VARIATION WILL EXPEDITE THE PROJECT AND NOT INCREASE THE EXPENSE TO THE OWNER OR VIOLATE ANY CODES. THESE OPTIONS SHALL BE SUBJECT TO THE LUXOTTICA'S PROJECT MANAGER'S APPROVAL. I. J. IN ACCORDANCE WITH THE DRAWINGS, THOSE ITEMS WHICH ARE REMOVED, AND ARE NOT RELOCATED OR REUSED, SHALL BE DISPOSED OF BY THE G.C.; VERIFY WITH MACY'S PRIOR TO DISPOSAL OF ANY DISPLAY FIXTURES, ARTWORK, OR ASSOCIATED HARDWARE. ANY EXISTING RECEPTACLES TO REMAIN UNLESS NOTED OTHERWISE ON PLANS; REFER TO ELECTRICAL DRAWINGS. L. REMOVE ALL WALL VINYL FROM WALLS (AS REQUIRED) AND PREP WALLS FOR NEW FINISHES. WALL RECEPTACLE (@ 18"AFF U.O.N.) TELEPHONE FLOOR RECEPTACLE RETURN AIR GRILLE 2 x 2 LIGHT FIXTURE TRACK LIGHTING FLUORESCENT STRIP LIGHT RECESSED LIGHT S N. REMOVE WINDOW CRASH GRAPHICS (D) FIXTURE TO BE DEMOLISHED DIRECTIONAL LIGHT SPRINKLER HEAD FIXTURE TO BE RELOCATED SECURITY CAMERA ILLUMINATED EXIT SIGN P. NOT USED Q. SIGN CONTRACTOR SHALL REMOVE ALL SIGNAGE IN OLD (OR TEMPORARY) SPACE AT END OF PROJECT, AS REQUIRED BY LEASE REQUIREMENT. R. NOT USED S. 16. REMOVE MOTION SENSOR & SMOKE DETECTOR, THIS AREA; COORDINATE WITH MACY'S TO DETERMINE IF THESE ITEMS AND ANY ADDITIONAL CEILING EQUIPMENT NOT SHOWN ON THIS PLAN, ARE TO BE SALVAGED OR DEMOLISHED. COORDINATE ANY SYSTEMS SHUTDOWNS WITH LANDLORD & INCLUDE COSTS OF SHUTDOWN IN THE BID. REMOVE ALL INTERIOR GRAPHICS AND WAYFINDING, TYPICAL IN ALL AREAS (RETAIL, EMPLOYEE, OD). DO NOT REMOVE FROM LENS PROCESSING AREA. H. EXCEPT AS NOTED, G.C. SHALL INCLUDE COSTS TO CUT, PATCH AND/OR REPAIR EXISTING WORK AND EXISTING FACILITIES WHICH MAY BE DISTURBED DURING INSTALLATION OF NEW WORK IN BID PACKAGES. T. PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEET, AND ARE IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT LUXOTTICA PROJECT MANAGER PRIOR TO INSTALLATION. (R) B.O. CEILING VERIFY IN FIELD NAME: DATE: REG NO: ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title GRAPHIC LEGEND DEMOLITION FLOOR & CEILING PLANS: AREA B & C LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF WORK TEMPORARY BARRICADE WALL Date EXISTING ITEM TO REMAIN EXISTING ITEM TO BE DEMOLISHED 73052 SPEAKER (E) G.C. TO PROVIDE AND INSTALL TEMPORARY BARRICADE. REF THIS DRAWING FOR INFORMATION ZIPWALL FOAMRAIL SPAN @ CEILING & WALLS Nextore project Number G.C. TO INSPECT ALL EXISTING WALLS TO REMAIN AND ENSURE THAT THEY ARE UP TO CURRENT SPECIFICATIONS. O. ZIPWALL DUST BARRIER SYSTEM PROVIDED AND INSTALLED BY G.C. G.C. TO VERIFY WITH SITE LOCATION STORE OPERATIONS MATERIAL TO BE USED. EITHER CLEAR PLASTIC OR TARP (FIRE RETARDANT). VERIFY CEILING FOR POLE SIZE REQUIRED. SUPPLY AIR DIFFUSER M. G. 18. PRIOR TO START OF CONSTRUCTION, G.C. TO PROVIDE BARRICADE AT AREA OF NEW STOREFRONT, IN COMPLIANCE WITH MALL MANAGEMENT REQUIREMENTS; BARRICADE SHALL REMAIN INTACT THROUGH DURATION OF WORK; G.C. SHALL PATCH & REPAIR ANY DAMAGE CAUSED UPON REMOVAL OF BARRICADE 86" EXISTING FIXTURE TO REMAIN 15. OPEN TO DECK ABOVE; REMOVE LIGHT FIXTURES AS INDICATED ON PLAN AND RETURN TO MACY'S 17. PARTIALLY EXPOSED PIPE TO REMAIN SYMBOL LEGEND ANY EXISTING DOORS AND FRAMES TO BE REMOVED UNLESS NOTED OTHERWISE ON PLANS; REFER TO DOOR SCHEDULE. K. Seal Sheet Drawn By ZIPWALL GRIPDISKS LLB BARRICADE DETAIL N.T.S. 07-01-16 Checked By REV 0.4 ANP AD100B PRETEST 102 103 3 LCI-GH30 4 EQ112 7 8 7 SE-OD02 SE-OD03 SE-OD01-L 13 A200 11 12 10 00C 16 A200 N.I.C. EXTG ELEV LOBBY 3 107 GS-CW20 GS-CL02-R 13 A200 11 SK3 WAITING LCI-GH30 GS- EQ21 FE 12 GS-FN04 11 PW GS- G RECESSED ELECTRIC PANEL GS-PW10 OPTICAL STATION N.I.C. 104 GS -PW -FN GS 14 1 0 A2 0 1 EQ EQ22A FRAME WARMER (HOT AIR) USED EQ100A SINGLE POWER TABLE USED EQ100C TRIPLE POWER TABLE USED EQ101 TONOMETER USED EQ102 AUTO-REFRACTOMETER USED EQ105C FIELDS TESTER USED EQ108 PATIENT CHAIR USED EQ109B REFRACTION STAND USED EQ112 STOOL USED EQ118C CHAIR MOVER Revisions: Mark EQ119 USED CHART HOLDER CHART HOLDER (WALL MOUNTED) USED SK3 SINK USED SK7 SINK 1 DESCRIPTION USED GS-FN07 STOOLS FOR SELECT TABLE GS-FN04 LOUNGE CHAIR REMARKS USED GS-FN08(A)(B)(C) ADJ. TASK CHAIR("A"-HARD SURF. "B"-CARPET "C"-CALIFORNIA) USED GS-FN09 SIDE CHAIR GS-FN09C SIDE CHAIR (CALIFORNIA STORES) GS-FN02(A)(B)(C) ADJ. STOOL ("A"-HARD SURF. "B"-CARPET "C"-CALIFORNIA) GS-FN05 SIDE TABLE (W/ GS-FN04 CHAIRS) 12 RETAIL 101 USED GS-CW20 CASHWRAP, LC SIS GS-CW20W CASHWRAP, LC SIS (REQUIRES WIRING BY GC) USED GS-LF10 27" (H) JOJO USED GS-LF11 35" (H) JOJO USED GS-LF13 FRONT DOOR FOCAL USED W 70 -FN GS 07 GS-LF53 GS- 1 GS-LF50 CAPACITY FIXTURE ENDCAP GS-LF51 CAPACITY FIXTURE, 2-BAY GS-LF52 CAPACITY FIXTURE, 3-BAY GONDOLA MONITOR GS-LF70 FITTING/SELECT TABLE GS-LF70W FITTING/SELECT TABLE (REQUIRES WIRING BY GC) GS-LF71 FITTING/CASHWRAP GS-LF71W FITTING/CASHWRAP (REQUIRES WIRING BY GC) GS-LF90 COLUMN PANEL, WITH BRAND MENU BLOCKING BLOCKING PROVIDED AND INSTALLED BY G.C. USED GS-PW01A (L)(C)(R) 3 1/8" PERIMETER FIN ("L"=LEFT "C"=CENTER "R"=RIGHT) USED GS-PW10 48" (W) PERIMETER WALL UNIT USED GS-PW11 25" (W) PERIMETER WALL UNIT GS-PW30 18" (W) MIRROR CABINET WITH STORAGE GS-PW31 12" (W) MIRROR CABINET WITH STORAGE GS-PW60 BACKWRAP FEATURE GS-PW60_55 BACKWRAP W/ 55" DIGITAL MONITOR GS-PW60_75 BACKWRAP W/ 75" DIGITAL MONITOR GS-PW61 BACKWRAP FEATURE WITH SIGNAGE GS-PW61_55 BACKWRAP FEATURE W/ SIGNAGE & 55" DIGITAL MONITOR GS-PW61_75 BACKWRAP FEATURE W/ SIGNAGE & 75" DIGITAL MONITOR GS-PW62 BACKWRAP FEATURE WITH WOOD FRAME GS-PW62_55 BACKWRAP FEATURE W/ SIGNAGE, PORTAL FRAME, & 55" DIGITAL MONITOR GS-PW62_75 BACKWRAP FEATURE W/ SIGNAGE, PORTAL FRAME, & 75" DIGITAL MONITOR GS-PW80 FILLER WITH MIRROR, NO STORAGE GS-PW81 PORTAL VERTICAL MODULE GS-PW82 PORTAL HORIZONTAL MODULE GS-PW83 WOOD FIN VERTICAL GS-PW84 CORNER FILLER GS-PW91 SERVICE TOTEM, WALL MOUNTED GS-PW93 MIRROR, OVERALL SIZE MATCHES LF90/93 USED GS-PW94 FRAME LEDGE, 26" W USED GS-PW95 FRAME LEDGE, 48" W USED BOH-UP24 UPPER CABINET USED GS-BOH01 WORK COUNTER FOR SIS USED GS-CL02 SINK BASE FOR SIS USED SE-CL03 CONTACT LENS STORAGE USED SE-OD01 DOCTORS DESK USED SE-OD02 SINK BASE USED SE-OD03 SINK CABINET ABOVE GS-LF13 LCM-MW-CS MAIN WALL CABINET SIGN MAIN WALL CABINET SIGN GENERAL NOTES 3. DOCTOR'S EQUIPMENT (EQXXX); REFER TO RESPONSIBILITY SCHEDULE ON G002. 4. COAT HOOK AT 54" TO CENTERLINE OF HOOKS. 5. 2A-10BC FIRE EXTINGUISHERS AS DIRECTED BY THE FIRE MARSHAL. (SUGGESTED LOCATIONS ON PLAN.) 6. ROOM SIGNAGE TO BE MOUNTED 9" FROM EDGE OF DOOR FRAME HORIZONTALLY TO CENTER OF GRAPHIC & 5'-0" VERTICALLY FROM FLOOR TO CENTER OF GRAPHIC. REF: ELEVATIONS. A. B. C. D. E. F. G. 7. COORDINATE MILLWORK SIZES, CONSTRUCTION & FINISHES WITH TENANT'S MILLWORKER; ALL FIELD COORDINATION TO BE VERIFIED PRIOR TO MILLWORK FABRICATION; REF: ELEVATIONS FOR FURTHER MILLWORK INFORMATION; APPLY PAINTABLE CAULK WHERE MILLWORK MEETS WALL, TYP. 8. INSTALL GS-PW FIXTURES SEQUENTIALLY STARTING AT THIS POINT. GC TO VERIFY ADJACENT WALL IS CLEAN, LEVEL, STRAIGHT AND PLUMB. 9. DOCTOR'S CERTIFICATES/ LICENSES TO BE INSTALLED AT THIS LOCATION. G.C. TO REFERENCE FIXTURE CONTRACTORS SHOP DRAWINGS FOR INSTALLATION INSTRUCTIONS FOR ALL FIXTURES, WALL CABINETS, BASE CABINETS, AND COUNTERTOPS. G.C. TO COORDINATE WITH FIXTURE CONTRACTOR TO ENSURE PROPER FIT OF ALL COMPONENTS. G.C. TO ENSURE FIXTURES ARE PROTECTED DURING CONSTRUCTION. G.C. TO PROVIDE ADEQUATE BLOCKING, AS REQUIRED, IN WALLS TO SUPPORT WALL CABINETS, FIXTURES & ACCESSORIES. G.C. TO FURNISH AND INSTALL LOCKSET OPERATIONAL BY TENANT ONLY. G.C. TO SIGN FOR PACKAGES WITH A NOTE "SUBJECT TO CONCEALED DAMAGES" ON IT. G.C. TO REFER TO GRAPHICS STANDARD MANUAL IN EVOCO FOR GRAPHIC MOUNTING HEIGHTS, TYPICAL. E = EXISTING TO REMAIN R = EXISTING TO BE RELOCATED FUT= FUTURE EQUIPMENT CAPACITY CALCULATIONS FIXTURE TYPE 48" WALL FIXTURE 10. CHART HOLDER MOUNTED 1'-0" FROM DOOR EDGE TO CENTER OF HOLDER HORIZONTALLY, AND 3'-10" FROM FLOOR TO CENTER OF HOLDER VERTICALLY. 11. LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF CONSTRUCTION 12. NOT IN CONTRACT; NO WORK IN THIS AREA, U.O.N. 13. EXISTING COLUMN TO REMAIN 24" WALL FIXTURE LCM-FW-CS FOCAL WALL CABINET SIGN LCM-EE-CS EYE EXAMS CABINET SIGN REMARKS LCM-FW-CS.1 FOCAL WALL CABINET SIGN FOR 75” DIGITAL MONITOR BACK WRAP USED LCM-GR-32 ROOM ID SIGNS USED LCI-GH-30 OD SNAP FRAMES USED SE-GH-23 CERTIFICATE / LICENSE SNAP FRAMES USED LCM-GH-16 DOCTOR'S NAME SLAT SIGN BLOCKING based on REV 0.2 CAPACITY TOTAL 3 69 207 FOR CLASS A, B AND C FIRES STAPLES (800) 333-3330 SIMPLEHUMAN QUICK LOAD PAPER TOWEL HOLDER WALL MOUNT - STAINLESS STEEL - ITEM#180969 MDL: KT1024 NONE REFRACTION ROOM PAPER TOWEL HOLDER - FREESTANDING STAPLES (800) 333-3330 SIMPLEHUMAN TENSION ARM PAPER TOWEL HOLDER STAINLESS STEEL. ITEM#:180971 MDL#: KT1161 NONE CONTACT LENS ROOM, OPTICAL STATION COAT HOOK GRAINGER 1-800-GRAINGER 10G182 POLISHED CHROME DOUBLE ROBE HOOK, MODEL #01-9402, NONE OD ROOMS; INCLUDES MOUNTING HARDWARE STAINLESS STEEL TRASH CAN STAPLES (800) 333-3330 SIMPLEHUMAN 16 GALLON BULLET OPEN CAN #CW 1405 S.S. NONE REFRACTION ROOM PAPER TOWEL HOLDER - WALL MOUNTED WALL STANDARDS BRACKETS KNAPE & VOGT (OR EQUAL) KNAPE & VOGT (OR EQUAL) HEAVY DUTY STEEL STANDARD NONE #KV85ANO (DOUBLE SLOT), WHITE HEAVY DUTY W/ LOCK NUT NONE #KV187ANO, WHITE 3/4" TH. X 12"D WHITE MELAMINE FINISHED ON NONE ALL SURFACES SHELVING GYPSUM BOARD CERTAINTEED ENDCAP 3 16 48 FIBERGLASS INSULATION OWENS CORNING 2-BAY TABLE 0 92 0 CEILING ACCESS PANEL WIND-LOCK 3-BAY TABLE 3 144 432 1 20 20 843 REMARKS ALTERNATE (800) 323-0620 136 850 MODEL #/COLOR (800) 233-8990 (800) 872-5625 PROROC BRAND GYPSUM BOARD NONE LIGHT DENSITY FIBERGLASS BUILDING INSULATION PRODUCTS NONE TR-AP024 24" X 24" ACCESS PANEL NONE DATE: 07-01-16 REG NO: 20474 Seal NAME: DATE: PRO LINE #PR02-STCM BRACKET 4T307 KIDDE / GRAINGER PARTS OF AMERICA 34 TOTAL NOTE: ALL SPECS MAY NOT BE USED IN EVERY STORE GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS LARSEN'S 800-633-6668 (MP SERIES-MP5, W/B-2 WALL BRACKET FIRE EXTINGUISHER - MULTI-PURPOSE DRY CHEMICAL TYPE: UL RATED 1-A 10-B/C, 5 LB 4 ENGATEMENT TABLE 14. EXISTING MILLWORK FASCIA AND LIGHTING LENSES TO REMAIN; PROTECT DURING INSTALLATION OF FIXTURES QUANTITY MISC. OTHER ARCHITECTURAL SPECIFICATIONS / FINISHES ITEM / DESCRIPTION MFG./PHONE # GLENN S. YEAKEL Engineer REV 0.7 # NAME: 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 DESCRIPTION LCM-MW-CS.1 BLOCKING Seal COLUMN PANEL, WITH MIRROR FIXTURE - FLOOR PLAN CENTERLINE OF FIXTURE; G.C. RESPONSIBLE FOR CONTACTING MILLWORKER UPON ANY DISCREPANCY BETWEEN ACTUAL FIELD LOCATION OF CENTERLINE AND WHAT IS INDICATED IN CONSTRUCTION DOCUMENTS. CLIENT COMMENTS 281 Farmington Avenue Farmington, CT. 06032 3" PERIMETER FIN ("L"=LEFT "C"=CENTER "R"=RIGHT) NORTH 2. 07/19/16 ASSOCIATES INC. GS-PW01 (L)(C)(R) 52 SCALE: 1/4" = 1'-0" REMARKS GS-LF93 GRAPHICS # GRAPHIC PACKAGE ITEMS; REFER TO RESPONSIBILITY SCHEDULE ON G002 AND GRAPHICS SCHEDULES THIS SHEET FOR RESPONSIBILITIES. REFER TO INTERIOR ELEVATIONS FOR MOUNTING DIMENSIONS AS APPLICABLE. Description SUBMIT FOR PERMIT 2016-026A GS-LF53 SERVICE TOTEM, FLOOR FIXTURE LF21 GS-LF11 GS-LF52 GS-LF53 SELECT BAR GS-LF50 EASEL FIXTURE USED GS-LF50 GS-LF42 GS-LF92 LF10 07 -FN GS 33" (H) ENGAGEMENT TABLE GS-LF91 1 6" GS-LF50 27" (H) ENGAGEMENT TABLE GS-LF21 USED USED F S- L GS-LF20 USED 12 1. By 07/07/16 Architect of Record DESCRIPTION USED USED 1" 3'-5 2 -LF GS FIXTURE PLAN - KEY NOTES Date BLOCKING PROVIDED AND INSTALLED BY G.C. BLOCKING PROVIDED AND INSTALLED BY G.C. LCD SCREEN USED USED " 6'-3 1_75 6 W P G S- GS- 1 Macy's Store Number: (687) USED USED 14 5' - 12 01A_L GS-PW 01A_CW01A_R GS-PW A_C W31 GS-P 1 0 W GS-P GS-P 07 G A200 _L 01A PW GS- _R 01A PW GS- 20W CW GS- 07 -FN GS 11 2 2 EQ 14 6" EXTG SALES AREA GS-PW01A_R _R 01A PW GS- _L 01A PW GS- C A_ 01 5' - GS-PW01A_L -PW GS 1 C 3 _ A W 01 S-P -PW G S G _L A 01 1 W1 S- P G R A_ 01 W P S- _75 W61 S -P 11 PW " 5' - 0 10 -PW GS BOH-UP24 EQ6 EQ22A 12 G BOH-UP24 EQ8C 7 11 BOH-UP24 15 11 GS-PW 10 GS-PW 3 5 A200 4 1 5 9 GS-FN04 GS-FN08B 12 8 106 GS-PW94 3 EYE NET STATION USED MILLWORK # BOH-UP24 7 FRAME TRACER EQ21 14 W91 N.I.C. 2" GS-FN02B EQ8C USED +1 (516) 393-2484 BLOCKING GS-PW95 G S- P NEW STOCK 9 GS-FN08B 105 USED GS-LF52 CONTACT LENS LENSOMETER (MANUAL) LENSOMETER (AUTO) N.I.C. OPTOS EQ100A SE-TOWEL-C BOH-UP24 EQ6 EQ6A FURNITURE # EXTG MECH EQ102 GS-FN08B CASHWRAP EQ6A EQ101 EQ105C USED USED REMARKS +1 (513) 765-6000 p 5 EQ1 10 6 GS-FN02B EXISTING EGRESS TO BE MAINTAINED THROUGHOUT CONSTRUCTION 9 A200 7 LCM-GR32 SE-GH-CHART 6 FE 1 GS-FN09 N.I.C. GS-LF92 EQ109B N.I.C. LCI-GH30 LCI-GH16 EQ108 EQ119 EXTG STAIRS EXTG VESTIBULE 1 DESCRIPTION p 6 Creamery Brook, East Granby, CT 06026 FR I A R EXAM ROOM EQUIPMENT # 4000 Luxottica Place, Mason, OH 45040 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 FIXTURE FLOOR PLAN - SCHEDULES USED IN PROJECT a a REG NO: Nextore project Number 73052 ISSUED FOR: REFER TO ELEV. FOR SIZE; PROVIDE BLOCKING AS REQUIRED Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title FIXTURE FLOOR PLAN SHELVING RATED AT 100 LBS. FASTEN SHELVES TO BRACKETS (DOUBLE SLOTTED STANDARDS) RETAIL SALES AREA Date 07-01-16 Sheet Drawn By REV 0.3 LLB Checked By ANP A100 KEY NOTES GENERAL NOTES - CONSTRUCTION EXAM ROOM PRETEST 102 103 EXTG VESTIBULE 1 7 8'-0" HOLD V.I.F. EXTG STAIRS N.I.C. 12'-0" HOLD 4 1'-3" EXTG MECH SE-OD02 1 4'-7" EXTG ELEV LOBBY 1 N.I.C. 107 5'-812" C. GC IS RESPONSIBLE FOR INSTALLING ALL FINISH FLOORING. GC IS ALSO RESPONSIBLE FOR ALL FINISH WALL MATERIALS BEHIND AND UNDER ALL MILLWORK. D. GC SHALL SUPPLY AND INSTALL BLOCKING IN ALL WALLS AS REQUIRED TO SUPPORT WALL SHELVING AND CABINETS. ANCHOR BLOCKING W/ SCREWS AT TOP MIDDLE AND BOTTOM (NO SILICONE). REFER TO ELEVATIONS AND MILLWORK SHOP DRAWINGS FOR MOUNTING HEIGHTS. 103 F. REFER TO SPECIFICATION G-00X SHEETS G. NO MATERIAL SUBSTITUTIONS WILL BE PERMITTED UNLESS SUBMITTED TO NEXTORE PROJECT MANAGER FOR REVIEW AND APPROVAL. H. ALL MANUFACTURERS RECOMMENDED INSTALLATION AND MAINTENANCE PROCEDURES ARE TO BE FOLLOWED BY GENERAL CONTRACTOR ON THIS PROJECT. I. GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE REPRESENTATIVE LISTED AS SOON AS CONTRACTS ARE AWARDED TO COMMUNICATE DESIRED SCHEDULE DATES AND PROJECT INFORMATION. 6 2 1 9 2 10 1 2 11" 12'- F. V. I . 170* V.I.F. 1'-5" 5 RETAIL " 11 8'- I.F. V. K. ANY QUESTIONS CONCERNING THESE SPECIFICATIONS SHALL BE DIRECTED TO THE PROJECT MANAGER FOR DOCUMENT CLARIFICATION. L. ALL TENANT FURNISHED ITEMS (MATERIAL AND LABOR) TO BE SCHEDULED, COORDINATED & SUPERVISED BY GC. M. FIRE MARSHAL TO DETERMINE FINAL LOCATION OF FIRE EXTINGUISHERS. N. ALL DIMENSIONS ARE TO FACE OF GYP. BD. UNLESS NOTED OTHERWISE ON PLANS. O. IN A REMODEL WHERE WALL COVERING IS TO BE REMOVED, SKIM AND FINISH WALL TO LEVEL 4 FINISH. P. ALL GYP. WALL BOARD TO BE FINISH LEVEL 4. CEILING GYP. TO BE LEVEL 5 FINISH. Q. PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEETS AND ARE IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT NEXTORE PROJECT MANAGER PRIOR TO INSTALLATION. RECESSED ELECTRIC PANEL 2'-10" N.I.C. 104 1 312" 2 2. NOT IN CONTRACT; NO WORK IN THIS AREA, U.O.N. 3. EXISTING WALL TO REMAIN, GC TO PATCH & REPAIR AS REQUIRED, TO RECEIVE NEW FINISH, TYP. 4. WALLS TO RECEIVE NEW PAINT OR WALLCOVERING FINISH SHALL BE PREPARED TO LEVEL 4 FINISH; WALLS TO RECEIVE TILE OR OTHER FINISH SHALL BE PREPARED PER FINISH MANUFACTURER'S RECOMMENDATIONS; REF: FINISH SCHEDULE, INTERIOR ELEVATIONS & DETAILS FOR FINISH INFORMATION 5. NEW ELECTRICAL PANEL; REF: ELECTRICAL DRAWINGS FOR MORE INFORMATION 6. NEW PUMP AND 18"x18" ACCESS PANEL; REF: PLUMBING DRAWINGS FOR PUMP INFORMATION 7. BUILD-OUT FURRED ENCLOSURE AS REQUIRED TO ENCLOSE EXPOSED PIPE 8. ACCESS TO CLEAN-OUT IN FLOOR SLAB SHALL BE MAINTAINED 9. NEW 6" ALUMINUM STOREFRONT SYSTEM TO MATCH EXISTING ADJACENT, SHALL MAINTAIN EXISTING WALL RATING; CONFIRM IN FIELD; PROVIDE SHOP DRAWING SUBMITTALS FOR REVIEW AND APPROVAL. LEVER 2'-6" TO 3'-8" 1 A. PREPARE / PATCH AND REPAIR SURFACES TO "LIKE NEW" CONDITION, (A LEVEL 4 FINISH) AND PREP TO RECEIVE NEW PAINT AS SCHEDULED. B. G.C. TO VERIFY PROPER WORKING ORDER OF ALL EXISTING DOORS AND HARDWARE (WHICH ARE DESIGNATED AS BEING RE-USED). REPAIR/REPLACE MATERIALS AS REQ'D. C. G.C. TO COORDINATE ALL EXISTING DOORS TO REMAIN WHICH WILL RECEIVE A NEW FINISH. THIS INCLUDES DOOR REMOVAL, HARDWARE REMOVAL AND REPLACEMENT, SCUFFED/ SANDED / APPLICATION OF NEW FINISHES AND RE-INSTALLATION. D. REFERENCE DOOR SCHEDULE THIS SHEET. VERIFY EXISTING HARDWARE AND SUPPLEMENT AS REQUIRED. (EXAMPLE; IF CLOSER IS SCHEDULED, WHICH DOES NOT EXIST, A NEW CLOSER IS TO BE INSTALLED IN ACCORDANCE WITH PROJECT SPECIFICATIONS. E. G.C. TO PROVIDE LOCK CYLINDERS COMPATIBLE WITH INSTA-LOCK CORES. F. VERIFY RE-KEYING REQUIREMENTS WITH NEXTORE CONSTRUCTION MANAGER PRIOR TO BID. G. WHERE NEW DOOR SLABS ARE TO BE INSTALLED, RE-USING EXISTING FRAMES, FIELD VERIFICATION OF DOOR SLAB SIZE IS REQUIRED. H. NOT USED I. WHERE DOORS ARE EXISTING TO REMAIN, ANY KNOB HARDWARE IS TO BE REPLACED WITH LEVER-STYLE HARDWARE; G.C. TO FIELD VERIFY. 281 Farmington Avenue Farmington, CT. 06032 NO SCALE DOOR WIDTHS AND HEIGHTS. REQUIRED EXIT DOORWAYS ARE REQUIRED TO HAVE A CLEAR OPENING NOT LESS THAN 32 INCHES WIDE. FOR HINGED DOORS, THE OPENING IS MEASURED WITH THE DOOR AT A 90 DEGREE ANGLE FROM ITS CLOSED POSITION. AT LEAST ONE OF A PAIR OF DOORS, INCLUDING AUTOMATIC DOORS, HAS TO PROVIDE THE 32 INCH CLEAR OPENING. DOOR HEIGHTS ARE REQUIRED TO BE A MINIMUM OF 80 INCHES. HARDWARE. HAND ACTIVATED DOOR OPENING HARDWARE IS REQUIRED TO BE CENTERED BETWEEN 30 AND 44 INCHES HIGH. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL HAVE TO BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, BY PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS ARE REQUIRED TO OPERATE AT DESCRIBED ABOVE IN THE DIRECTION OF EGRESS. CLOSERS. THE MAXIMUM EFFORT TO OPERATE DOORS CANNOT EXCEED 8.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS. REQUIRED FIRE DOORS MAY REQUIRED UP TO 15 POUNDS PRESSURE. THE PRESSURE IS TO BE MEASURED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE REQUIREMENTS. IF A DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 INCHES (75 mm) FROM THE LATCH, MEASURED TO THE LEADING EDGE OF THE DOOR. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS SHALL BE 44" A.F.F. TO CENTERLINE. DOOR TYPES CASED OPENING 1 2 3 4 MODEL #/ COLOR 93K-7-R-15-D-STK "CLASSROOM" BEST ACCESS SYSTEMS FINISH - US26D BUTT HINGES (1-1/2 PAIR FBB-179, 4-1/2" x 4-1/2" STANLEY HARDWARE FINISH - US26D PER DOOR) #407-1/2" CONCAVE WALL BUMPERS IVES ALUM SILVER MFR. DESCRIPTION FLOOR STOPS IVES #436 ALUM SILVER SOLID CORE WOOD DOORS / PL-LAM DOORS COMMERCIAL DOOR & HARDWARE SEE DOOR SCHEDULE HOLLOW METAL DOORS COMMERCIAL DOOR & FRAMES & HARDWARE SEE DOOR SCHEDULE ALTERNATE SCHLAGE REMARKS KEY OPERATED ON OUTSIDE ONLY ROOM NAME SUBSTRATE ADHESIVE TO HAVE A VOC LIMIT OF 30 g/L LESS WATER NO ADDED UREAFORMALDEHYDE RESINS FSC WOOD 2" EXISTING MASONRY OPENING V.I.F. 2" DOOR WIDTH DOOR HEIGHT DOOR HEIGHT DOOR HEIGHT DOOR HEIGHT REF: DOOR SCHEDULE DOOR HEIGHT REF: DOOR SCHEDULE DOORS WIDTH BROOKLINE #1330A 1 2" 2" 2 3 KAWNEER (770) 449-5555 HAGER HINGE CO. (314) 772-4400 DETEX CORP. (800) 729-3839 OLD CASTLE (800) 222-1853 YALE COMMERCIAL (800) 438-1951 STANLEY HARDWARE (800) 622-4393 IVES (877) 671-7011 SCHLAGE (800) 847-1864 DESCO (201) 568-4920 PACIFIC PRODUCTS ALUMATEC (877) 770-0181 COMMERCIAL DOOR & HARDWARE 2784 NEWPORT HIGHWAY SEVIERVILLE, TN 37876 (865) 429-8980 THE SLIDING DOOR COMPANY SHERYL HAI-AMI (805) 497-8686 EXT 225 BEST ACCESS SYSTEMS (317) 849-2250 NATIONAL GUARD PRODUCTS INC. (800) 647-7874 DOOR SIZE HEIGHT THICK FRAMES DOOR DESCRIPTION MATERIAL FINISH TYPE 07-01-16 REG NO: 20474 Engineer GLAZING LABEL TYPE MATERIAL FINISH P104 LABEL NONE HEAD JAMB DESCRIPTION CLOSER THRESHOLD NO KICK FLR NO 101 3'-0" 6'-8" 1 3/4" A WOOD PL105 NONE NONE 1 HM WAITING ROOM 102 3'-0" 6'-8" - B ALUMINUM CLR ANODIZED TEMPERED AS REQ'D 2 ALUMINUM CLR ANODIZED AS REQ'D 3/A101 DOOR TO MATCH EXISTING MACY'S VESTIBULE DOOR LOBBY ENTRY 103 3'-0" 6'-8" - B ALUMINUM CLR ANODIZED TEMPERED AS REQ'D 3 ALUMINUM CLR ANODIZED AS REQ'D 3/A101 NEW STOREFRONT SYSTEM; DOOR TO MATCH EXISTING MACY'S VESTIBULE DOOR 1/A101 LEVER/CLASS-RM NO STOP 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Seal INSTA-KEY (800) 316-5397 PEMKO MFG. CO. (805) 642-2600 ALUMATEK 800-949-9950 KNAPP & VOGT (800) 253-1561 OR WWW.KV.COM NAME: DATE: REG NO: 73052 REV0.1 REMARKS HARDWARE EXAM ROOM - REFER TO PLAN FOR PROPER DOOR SWING DIRECTION - ALL WOOD DOORS TO BE PROVIDED BY MILLWORKER, INSTALLED BY G.C. DATE: Nextore project Number WALL LEGEND MARK GLENN S. YEAKEL EXIT DOORS, TOILET ROOM AND CHANGING ROOM DOOR TO BE OPENABLE FROM INSIDE WITHOUT SPECIAL KNOWLEDGE, FORCE OR NEED OF KEY. SEE SPECIFICATION SHEET FOR RESPONSIBILITIES. ALL HARDWARE TO BE LEVER TYPE. DOOR SCHEDULE HAGER HINGE CO BROOKLINE #1326-CV CONCAVE B A 2" 1'-6" STOREFRONT 2" 9" 2" DOOR WIDTH 1'-6" HEAD - SLIDING DOOR NOTE: ALL SPECS MAY NOT BE USED IN EVERY STORE GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS 2" 1'-6" INTERIOR DOOR DOOR HARDWARE SCHEDULE 2" DOOR WIDTH 2" US ED O T 3/4" HARDWOOD PAINTED 7 8" (1) LAYER GWB OVER HAT CHANNELS REF: 3/A300 FOR WALL DETAIL DOOR WIDTH REF: DOOR SCHEDULE 2" DOOR WIDTH REF: DOOR SCHEDULE 3/4" N 4 NAME: DOOR HARDWARE MANUFACTURERS EXISTING MASONRY OPENING V.I.F. 3/4" US ED WOOD TRIM. PAINT TO MATCH ADJACENT WALL DOUBLE UPPER TRACK. PART OF JOHNSON HARWARE SET 138F602D FRAME TYPES 1 METAL STUD WALL WITH PAINTED GYPSUM BOARD BOTH SIDES O GWB (1) SIDE REF: 4/A300 FOR WALL DETAIL 3 4" CLIENT COMMENTS DOORS ENTRANCES. ALL PRIMARY ENTRANCES TO BUILDINGS AND FACILITIES ARE REQUIRED TO BE MADE ACCESSIBLE. A PRIMARY ENTRANCE IS DEFINED AS, "...ANY ENTRANCE TO A FACILITY WHICH HAS A SUBSTANTIAL FLOW OF PEDESTRIANS TO ANY SPECIFIC MAJOR FUNCTION OF THE FACILITY." REVOLVING DOORS CAN NOT BE USED AS A REQUIRED ENTRANCE FOR THE HANDICAPPED. RECESSED DOORMATS ARE REQUIRED TO BE ANCHORED TO PREVENT INTERFERENCE WITH WHEELCHAIR TRAFFIC. 2. 3. T DOOR: REFER DOOR SCHEDULE 07/19/16 Seal 1. NEW STOREFRONT FRAME; REF: DOOR SCHEDULE Description SUBMIT FOR PERMIT 2016-026A SCALE: 1/4" = 1'-0" N 3 METAL FRAME DOOR JAMB By THRESHOLDS. ALL DOOR THRESHOLDS SHALL COMPLY WITH LOCAL CODES, INCLUDING ACCESSIBILITY, TO MEET REQUIREMENTS FOR "CHANGES IN LEVEL FLOOR SURFACE"; BEVEL OR SLOPE EXPOSED EDGE AT AN ANGLE NOT EXCEEDING 45 DEGREES, SO THAT ALL VERTICAL CHANGES OF ELEVATION MEET SAID REQUIREMENTS. FRAME DETAILS 3-5/8" STUD, GWB (1) SIDE REF: 2/A300 FOR WALL DETAIL Date 07/07/16 ASSOCIATES INC. DOOR/HARDWARE DETAIL ENTRANCE SIGNS. ALL BUILDINGS ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY HANDICAPPED PERSONS SHALL BE IDENTIFIED WITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, TO BE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS. 2 Macy's Store Number: (687) 90° CONSTRUCTION - FLOOR PLAN EXISTING WALL A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Architect of Record NORTH METAL STUD WALL WITH PAINTED GYPSUM BOARD BOTH SIDES +1 (516) 393-2484 1 GENERAL DOOR NOTES 1 DBL 6" DP, 16 GA. BEAM WITH 3 5/8", 18 GA. TRACK TOP & BOTTOM #10 SCREW @ 12" c/c, TYP. #10-24 X 1" LONG SOCKET HEAD SCREW +1 (513) 765-6000 p Mark 2 3-5/8" STUD, GWB 2 SIDES REF: 1/A300 FOR WALL DETAIL p 6 Creamery Brook, East Granby, CT 06026 Revisions: 4 J. 1 4000 Luxottica Place, Mason, OH 45040 a 10. NEW GWB CONSTRUCTION (20 GA METAL STUDS @ 16" O.C. WITH 5/8" GWB ONE SIDE TO 6" ABOVE FINISHED CEILING, STUDS CROSS-BRACED TO STRUCTURE ABOVE) TO ALIGN WITH FOOTPRINT OF EXISTING, DEMOLISHED DISPLAY PANELS. PROVIDE IN-WALL BLOCKING; REF: A200. 2'-8" 1 WALL TYPES a CLEAR 2 1 LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF CONSTRUCTION .F. V. I OPTICAL STATION 1. 2 101 3" EXTG SALES AREA 8'-9" V.I.F. 170 V.I . ° F. ALIGN 3 ALIGN 2 GENERAL CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL UPCHARGES ASSOCIATED WITH THE DELAY OF ORDERING SPECIFIED PRODUCTS. 8" 4'-612" 8'-1" N.I.C. 106 1 4 EXISTING EGRESS TO BE MAINTAINED THROUGHOUT CONSTRUCTION 6'-5" 3'-3" WAITING 4'-1" 105 SK3 4'-4" GS-CL02-R NEW STOCK 1 BOH-UP24 3" V.I.F. CONTACT LENS BOH-UP24 2'-3" 8 1 J. C 1 ADEQUATE ACCESS PANELS OR DOORS SHALL BE INCORPORATED INTO TENANT WORK FOR INSPECTION SERVICE AND REPLACEMENT OF BOTH LANDLORD AND TENANT EQUIPMENT, COORDINATE PLACEMENT WITH LANDLORD'S ON-SITE REPRESENTATIVE. 2 N.I.C. CASHWRAP GC IS RESPONSIBLE FOR ANY PREPARATION OF THE FLOOR SLAB AND PROCUREMENT OF MATERIALS REQUIRED AT THE PERIMETER TO PRODUCE A FLUSH CONDITION BETWEEN THE LENSCRAFTERS FLOOR AREA AND THE EXISTING AREA FLOORING SURROUNDING. 9 2'-8" V.I.F. 4 1 9 A400 9" V.I.F. B. E. N.I.C. 3" V.I.F. 4 3 GC TO MAINTAIN ALL DIMENSIONS AS SPECIFIED. NOTIFY NEXTORE PROJECT MANAGER OF ANY DISCREPANCIES OF HOLD DIMENSIONS. FR I A R A. # LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF WORK EXISTING WALLS TO REMAIN, U.O.N. EXISTING ITEM TO REMAIN, U.O.N. NEW WALL 1 ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title CONSTRUCTION FLOOR PLAN Date 07-01-16 Sheet Drawn By REV0.1 LLB Checked By ANP A101 a 4000 Luxottica Place, Mason, OH 45040 p +1 (513) 765-6000 a 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 AC-4 C 10'-0"AFF AC-4 C 10'-0"AFF AC-4 10'-0"AFF EXAM ROOM PRETEST 102 103 Macy's Store Number: (687) EXTG VESTIBULE 1 EQ N.I.C. Mark 4 (N) AD EQ EQ (N) AD N.I.C. (N) (N) 4 (N) AD (N) AD-EM 9 N.I.C. 1 EXTG ELEV LOBBY CASHWRAP 107 N.I.C. 10'-0"AFF (N) 4 CONTACT LENS (R) WAITING 105 NEW STOCK X2 (N) 106 (E) N.I.C. 5 (N) AD 4 (N) AD-EM 2 (R) (N) (N) AD EQ EQ 1 (E) (E) (E) 7 (E) (E) (E) (E) (E) (E) (E) (E) (E) C 10'-0"AFF (E) (E) (E) EXTG TO REMAIN 11'-0"AFF 101 S 3 (E) (E) (E) (E) (E) (N) C (E) (E) (E) 1 (E) (N) (E) GS-LF53 3 EX/D1 (E) 2 EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON-SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION. E. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, G.C. SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION. F. LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. G. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE THRU-WIRING WHEREVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. LIGHTING FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE THRU-WIRING, ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. (E) (E) 07/19/16 CLIENT COMMENTS NORTH REFLECTED CEILING PLAN ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 2016-026A Seal G.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY LUXOTTICA. G.C. IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, G.C. SHALL CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH LUXOTTICA. I. EMERGENCY AND EXIT LUMINAIRES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST NATIONAL ELECTRICAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL-VOLTAGE WITH BATTERY BACKUP (120/277 VOLT INPUT). INSTALL A CENTRAL BATTERY SYSTEM WHERE THE USE OF INDIVIDUAL BATTERY UNITS ARE PROHIBITED BY LOCAL CODES. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION. J. G.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. K. G.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. L. CEILING GRID SHALL BE CENTERED IN ROOM UNLESS OTHERWISE NOTED. M. DOWN LIGHTS SHALL BE CENTERED IN TILE UNLESS OTHERWISE NOTED. NAME: GLENN S. YEAKEL N. G.C. TO TIE INTO EXISTING HVAC SYSTEM AS SUPPLIED BY MACY'S; G.C. RESPONSIBLE FOR SUPPLYING AND INSTALLING ANY NEW DUCTWORK OR MATERIALS ASSOCIATED WITH THE NEW LAYOUT, AND WILL BE RESPONSIBLE FOR BALANCING THE SYSTEM AS REQUIRED BY MACY'S; REF: MEP DRAWINGS FOR MORE INFORMATION DATE: 07-01-16 REG NO: 20474 O. NO ITEM SHALL BE ATTACHED TO, OR SUSPENDED FROM, THE DECK ABOVE; NO PENETRATIONS SHALL BE MADE TO DECK ABOVE; ALL EQUIPMENT, FIXTURES, ETC. SHALL BE ATTACHED TO TOP CHORD OF JOIST OR STRUCTURAL STEEL, TYP. U.O.N. P. HANGER WIRE AT SUSPENDED ACT CEILINGS SHALL BE 10 GA; AT SUSPENDED GWB CEILINGS SHALL BE 8 GA Q. ALL SUSPENDED CEILING SYSTEMS SHALL BE INSTALLED PER INDUCSTRY STANDARDS; ALL CODE REQUIREMENTS AND ALL RECOMMENDATIONS OF THE MANUFACTURER SHALL BE MET. R. DIFFUSERS TO BE SUPPORTED BY HANG WIRES AT ALL (4) CORNERS, TYP. A. G.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD. B. EXISTING SPRINKLER HEADS SHOWN EXISTING TO REMAIN UNLESS NOTED OTHERWISE. CONTACT ARCHITECT / ENGINEER IF CHANGES MUST BE MADE. GS-LF53 (E) Architect of Record H. 2 (E) 1 D. 3 (E) (E) (E) IT SHALL BE THE G.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE G.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. 2 (E) (E) (E) 3 C. (E) (E) 1 ALL NIGHT-LIGHT (NL) LUMINAIRES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING (E) EXTG TO REMAIN 10'-5"AFF (E) 6 (E) C (E) B. RETAIL (E) (E) 104 AC-4 (E) (E) 3 OPTICAL STATION N.I.C. (E) (E) (E) EXTG SALES AREA (E) (E) (E) (E) (E) (E) (E) (E) EMERGENCY (EM) LUMINAIRES SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT" TO PROVIDE CONTINUOUS POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF. (E) (N) AD 2 3 A. 2 8 4'-3" V.I.F. Description SUBMIT FOR PERMIT GENERAL NOTES - REFLECTED CEILING PLAN EQ (N) AD AC-4 7'-6" V.I.F. C By 07/07/16 X2 (N) EQ (N) Date 5 EXTG MECH EQ EXTG STAIRS Revisions: FR I A R C Engineer 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 SCALE: 1/4" = 1'-0" Seal MACY'S SYMBOL LEGEND SYMBOL 2 x 2 LIGHT FIXTURES SUPPLY AIR DIFFUSER TYPE AD AD RETURN AIR GRILLE TRACK LIGHTING AD- EM FLUORESCENT STRIP LIGHT SPEAKER S AD-EM SECURITY CAMERA RECESSED LIGHT FIXTURE X2 X2 ILLUMINATED EXIT SIGN SPRINKLER HEAD 2T-S TL DIRECTIONAL LIGHT 4T-S CEILING LEGEND TL 6T-S TL LEASE LINE EXISTING CEILING TO REMAIN, U.O.N. NEW CEILING (E) EXISTING FIXTURE TO REMAIN (R) RELOCATED FIXTURE KEY NOTES LIGHTING SCHEDULE REF: LIGHTING SCHEDULE FOR FIXTURE INFORMATION 8T-S TL (N) NEW FIXTURE 12T-S TL DESCRIPTION RECESSED 2X2 LED TROFFER SEE ELEC. SHEETS FOR MFG, SPECS ETC. (TYP. ALL LIGHTS IN SCHEDULE) RECESSED 2X2 LED TROFFER WITH EMERGENCY BATTERY BACKUP. 2T-S 2 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL GIMBAL STYLE LAMP-HOLDER, WHITE 4T-S 4 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL GIMBAL STYLE LAMP-HOLDER, WHITE 6T-S 6 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL GIMBAL STYLE LAMP-HOLDER, WHITE 8T-S 8 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL GIMBAL STYLE LAMP-HOLDER, WHITE 12T-S 12 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL GIMBAL STYLE LAMP-HOLDER, WHITE 1. LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF CONSTRUCTION 2. NOT IN CONTRACT; NO WORK IN THIS AREA, U.O.N. 3. EXISTING CEILING TO REMAIN; ALL FIXTURES TO REMAIN, U.O.N. 4. NEW ACT CEILING SYSTEM; HEIGHT OF NEW CEILING TO BE FIELD VERIFIED PRIOR TO INSTALLATION; REF: FINISH SCHEDULE FOR CEILING INFORMATION; REF: A300 FOR CEILING DETAILS 5. RECESSED EXTRUDED ALUMINUM EDGE LIT EXIT SIGN WITH RED LETTERS FOR CEILING OR WALL MOUNTING RED LED INCLUDED. TO BE RECESSED MOUNTED U.N.O. (FOR NYC OR CHICAGO CONFIRM WITH MANUF). PROVIDE CURRENT LIMITER WHERE REQUIRED. 1 # NEW ILLUMINATED EXIT SIGN TO COMPLY WITH ALL CODES; REF: MEP DRAWINGS FOR MORE INFORMATION 6. PLAN PROVIDES SUGGESTED SPRINKLER HEAD LOCATIONS; REF: SPRINKLER SYSTEM NOTES BELOW AND MEP DRAWINGS, TYP. 7. EXISTING MILLWORK FASCIA AND LIGHTING LENSES TO REMAIN; PROTECT DURING CONSTRUCTION 8. INFILL GWB CEILING TO MATCH EXISTING ADJACENT; PROVIDE SMOOTH AND CONTINUOUS FINISHED SURFACE 9. REF: P200 FOR SUGGESTED SPRINKLER LAYOUT SPRINKLER SYSTEM NOTES OD AREA ONLY CONTRACTOR SHALL PROVIDE A COMPLETE FIRE PROTECTION SPRINKLER SYSTEM FOR THE ENTIRE SPACE IN COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS AND THE LANDLORD'S CRITERIA. THE CONTRACTOR SHALL HAVE DRAWINGS, SHOP DRAWINGS, APPLICATIONS AND SUBMITTALS PREPARED BY A PROPERLY LICENSED PROFESSIONAL, WHO IS APPROVED BY THE LANDLORD. ALL DRAWINGS AND CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL CODES, REGULATIONS, INSURANCE ASSOCIATIONS AND RATING BUREAUS AND SHALL INCLUDE ALL PERMITS, TESTS, SHUT DOWN FEES AND CERTIFICATIONS TO PROVIDE A COMPLETE IN PLACE SYSTEM. NAME: CONTRACTOR SHALL REWORK AND MODIFY THE SYSTEM IF NECESSARY FOR THE NEW SPACE CONFIGURATION. MODIFICATIONS SHALL BE DESIGNED AND INSTALLED BY A QUALIFIED FIRE SPRINKLER CONTRACTOR, WHO SHALL PREPARE DESIGN/SHOP DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS TO THE LANDLORD AND BUILDING AND FIRE DEPARTMENTS FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA, STANDARD 101, AND ANY OTHER STATE OR LOCAL CODES HAVING JURISDICTION. DESIGN STANDARDS: MODEL 'G-4'; TYCO 'RF-11' RELIABLE MODEL "G-F1'; TYCO 'TY-L' RELIABLE MODEL "G"; 'TY-L' WHITE CONCEALED HEADS; RELIABLE RECESSED WHITE PENDANT HEADS WITH WHITE TRIM RINGS; WHITE PENDANT HEADS WITH WHITE TRIM RINGS; DATE: REG NO: Nextore project Number 73052 ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title REFLECTED CEILING PLAN Date 07-01-16 Sheet Drawn By REV0.2 LLB Checked By ANP A102 C63 F C63 B WB101 B WB101 W P101 W P101 EXAM ROOM PRETEST 102 103 EXTG VESTIBULE N.I.C. P114 N.I.C. F C63 B WB101 W P101 CASHWRAP 3 107 EXTG ELEV LOBBY 1 WALLS 3 N.I.C. 2 C 4 CONTACT LENS W 105 MFG./PHONE # 106 NEW STOCK 5 3 N.I.C. FLOORING RETAIL 101 1 F (800) 474-3794 PAINT P104 PAINT (SEMI GLOSS) (EXTRA WHITE) SHERWIN WILLIAMS (800) 474-3794 PAINT P114 PAINT (EGG SHELL) SHERWIN WILLIAMS (800) 474-3794 SW7066, GRAY MATTERS NONE PAINT P117 PAINT (SATIN) SHERWIN WILLIAMS (800) 474-3794 SW7068 GRIZZLE GRAY NONE EXTG SALES AREA OPTICAL STATION N.I.C. 104 1 C63 B WB101 W P101 ET RP CA W NE ISH FIN NEW CARPET FINISH 1 E IN TIL MA ING RE IST TO E X OR FLO 6 2 NONE DOOR FRAMES EVERYWHERE WALLCOVERING WOLF GORDON INC. HEIDI SCHWARZINGER REEF RFF 2557 VINYL WALLCOVERING WITH OSNABURG BACKING - COLOR: ANCHOR NONE WALLCOVERING WC106 WALLCOVERING SOURCE ONE CONTRACT MIKE THOMPSON, 614-551-7928 TEXTURA STONE, COLOR: BLACK DIMENSIONS: 12”X24”, 1-1/2” MM. THK. NONE 6" H x 3/4"T PAINTED WOOD BASE W/ 3/8" TOP CHAMFER WB101 BASE DWB101 MILLWORK WALL BASE WOOD WD201 CUSTOM WOOD MILLWORK CHAIR RAIL CR100 CHAIR RAIL JOHNSONITE CORNER GUARD CG100 VINYL CORNER GUARD JOHNSONITE PORCELAIN TILE PT105 PORCELAIN TILE (7 7/8" x 19 5/8" x 1/4" THK) PORCELAIN TILE PT108 LARGE FORMAT PORCELAIN TILE 24"x24"x10mm PORCELAIN TILE PT109 LARGE FORMAT PORCELAIN TILE A.) 24"x24"x10mm #PFP2960 B.) 24"x6"x10mm #PFP2965 WOOD WALL BASE NONE MILLWORKER MISSION OAK PANELING, LOW SHEEN POLYURETHANE FINISH. 1/2" THICK BY 4-1/2" WIDE NONE MOUNT OVER FIRE RATED PLYWOOD. SCHLUTER QUADEC @ OUTSIDE CORNER CONDITIONS. CHR-50-C NONE OD WAITING, EXAM & PRETEST PER ELEVATIONS ROD SEABOLT CDC DISTRIBUTORS (513) 560 - 1040 [email protected] 50 WHITE VBG-50-A-48 NONE USE ON EXPOSED OUTSIDE CORNERS IN RETAIL (EXCEPT IN STOREFRONT DISPLAY), O.D. & B.O.H. ROBYN DUBEN LOUISVILLE TILE (866) 321-7385 WAY, WHITE GROUT: 1/16" THK., MAPEI #38 AVALANCHE NONE STOREFRONT PORTAL FRAME, INSIDE WD201. VERIFY W ELEVATION TRANSCERAMICA 1159 W BRYN MAWR ITASCA IL 60143 NOREEN SCHERTLER (312) 342-4689 ROADS; ITEM #P66201 - SQUARE GREY CALM, (MATTE FINISH) GROUT: 1/16" THK., MAPEI #27 SILVER (NO SUBSTITUTIONS) NONE MANDATORY INSTALLATION PER MANUFACTURER'S SPECIFICATIONS. TRANSCERAMICA 1159 W BRYN MAWR ITASCA IL 60143 NOREEN SCHERTLER (312) 342-4689 NEW GROUND; ANTHRACITE GROUND, (HONED FINISH) GROUT: 1/16" THK., MAPEI #47 CHARCOAL (NO SUBSTITUTIONS) NONE JEFF TAYLOR (P): (800) 241-4586 ROBERT SCHULER (P): (800) 241-4586 STACKED MODULAR, 1404 STIMULATE 24x24 TILE NONE 1404 STIMULATE; 24"X24" TILES NONE TERRA MAI ATLAS CONCORDE CARPET TILE 24"x24", ULTRA NYLON 6,6 J&J INVISION CARPET TILE C65 RUSTED MODULAR; MULTI-LEVEL TIP SHEARED LOOP W NEXUS MODULAR BACKING J&J INVISION CEILINGS AC-4 A-1 ROD SEABOLT CDC DISTRIBUTORS (513) 560 - 1040 [email protected] 1774 DUNE TEGULAR, 2'x2'x5/8" ANGLED TEGULAR PRELUDE 15/16" EXPOSED TEE GRID SYSTEM NONE CLASS "A", REFERENCE "LUXOTTICA" AS ACCOUNT NAME ALUMINUM TIGER (800) 898-4437 TIGER DRYLAC 49/80180 NONE STOREFRONT GLAZING CHANNELS, 12' LENGTHS. STOREFRONT BASE, & 2" REVEAL PROFILE. NONE MILLWORK NONE MILLWORK NONE MILLWORK NONE DOORS (BOTH SIDES) NONE MILLWORK NONE TRIM DETAIL FOR WALLCOVERING, 2-PART ASSEMBLY NONE MILLWORK WILSONART (800) 433-3222 PLASTIC LAMINATE PL102 PLASTIC LAMINATE FORMICA MICHAEL HERTENSTINER (440) 668-7030 PLASTIC LAMINATE PL103 PLASTIC LAMINATE FORMICA MICHAEL HERTENSTINER (440) 668-7030 FROSTY WHITE #1573-60 MATTE W/SOLID COLOR CORE @ EXPOSED EDGES DECOMETAL COLLECTION 2022 BRUSHED ALUMINUM COLORCORE2 COLLECTION 7223C-58 NEW WHITE (MATTE) PLASTIC LAMINATE PL105 PLASTIC LAMINATE WILSONART (800) 433-3222 7964K-12 SKYLINE WALNUT MILLWORK FINISH PC100 MILLWORK POWDERCOAT MATTHEWS PAINT MP30136R11950 POWDERCOAT SOA V1.0 BRUSHED ALUMINUM RECTANGULAR TRIM #110672 W/ BASE #412007 FINISH - 120 S557 INTERNATIONAL WHITE / CRYSTAL TEXTURE ARCHITECTURAL METAL TRIM M102 MEL100 TS-1 METAL STYLMARK NADINE KING (763) 574-7474 MELAMINE PANOLAM (800) 672-6652 TRANSITION STRIP (CARPET TO TILE) JOHNSONITE TRANSITION STRIPS NORTH FINISH PLAN SCALE: 1/4" = 1'-0" TS-2 TRANSITION STRIP (CARPET TO CONCRETE) JOHNSONITE ROD SEABOLT CDC DISTRIBUTORS (513) 560 - 1040 PART # CCA-XX / #49 BEIGE NONE FLAME SPREAD: ASTME-84 75 OR LESS, CLASS B SMOKE DEVELOP:NA, FUEL CONTRIBUTED: NA ROD SEABOLT CDC DISTRIBUTORS (513) 560 - 1040 PART # EG-XX-K / #49 BEIGE NONE FLAME SPREAD: ASTME-84 75 OR LESS, CLASS B. SMOKE DEVELOP:NA, FUEL CONTRIBUTED: NA SCHIENE, MINIMAL HEIGHT AS APPROPRIATE FOR FLOORING TRANSITION ALUMINUM (-A); 1/4" THICK EDGE. NONE ZINC STRIP AT OD AREA. PART # CTA-XX-K / #49 BEIGE NONE BETWEEN PORCELAIN TILE & VINYL SCHLUTER - DECO, ALUMINUM (-A) HEIGHT AS APPROPRIATE FOR FLOORING TRANSITION, 1/4" THICK ALUMINUM EDGE NONE STOREFRONT ENTRY BETWEEN RETAIL TILE AND MALL TILE ROD SEABOLT CDC DISTRIBUTORS (513) 560 - 1040 PART # RRS-XXC / #49 BEIGE NONE FLAME SPREAD: ASTME-84 75 OR LESS, CLASS B SMOKE DEVELOP:NA, FUEL CONTRIBUTED: NA [email protected] TRANSITION STRIP TRANSITION STRIP TS-4 TRANSITION STRIP (CARPET TO VINYL AND CARPET TO PORCELAIN) TS-9 TRANSITION STRIP (PORCELAIN TO VINYL) SCHLUTER 1-800-472-4588 WWW.SCHLUTER.COM JOHNSONITE ROD SEABOLT CDC DISTRIBUTORS (513) 560 - 1040 TRANSITION STRIP TS-10 TRANSITION STRIP (PORCELAIN TO MALL TILE SCHLUTER 1-800-472-4588 FLOORING) WWW.SCHLUTER.COM TRANSITION STRIP TS-12 TRANSITION STRIP (VINYL TO CONCRETE) XXXX = BASE W XXXX = WALL T XXXX = TRIM G.C. IS RESPONSIBLE FOR ANY PREPARATION OF THE FLOOR SLAB AND PROCUREMENT OF MATERIALS REQUIRED TO PRODUCE A FLUSH CONDITION BETWEEN THE STORE LEASE LINE AND THE EXISTING MALL FLOORING. B. G.C. IS RESPONSIBLE FOR INSTALLING ALL FINISH FLOORING. G.C. IS ALSO RESPONSIBLE FOR ALL FINISH MATERIALS BEHIND AND UNDER ALL MILLWORK. C. 1. LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF CONSTRUCTION 2. NOT IN CONTRACT; NO WORK IN THIS AREA, U.O.N. 3. REFER TO ARCHITECTURAL SPECIFICATIONS, FINISHES SCHEDULE THIS SHEET & INTERIOR ELEVATIONS FOR FURTHER INFORMATION G.C. TO PATCH AND REPAIR EXISTING CONCRETE AS REQUIRED TO RECEIVE NEW FLOOR FINISH PER MANUFACTURER'S RECOMMENDATIONS; COORDINATE WITH NEXTORE PROJECT MANAGER FOR APPROVAL 4. D. ALL TENANT FURNISHED ITEMS (MATERIAL AND LABOR) TO BE SCHEDULED, COORDINATED AND SUPERVISED BY G.C. EXISTING CLEAN-OUT LOCATED IN FLOOR SLAB TO REMAIN; ENSURE NEW FLOORING INSTALLATION ALLOWS FOR ACCESS 5. E. REFER TO ELEVATIONS FOR FINISHES WITH MORE THAN ONE DESIGNATION ON FINISH PLAN NEW INFILL TILE AT AREA OF WALL DEMOLITION TO MATCH EXISTING, ADJACENT TILE; COORDINATE WITH MACY'S F. REFER TO DOOR SCHEDULE FOR DOOR FINISHES. 6. EXISTING TILE TO REMAIN G. PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEET AND ARE IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT NEXTORE PROJECT MANAGER PRIOR TO INSTALLATION. H. NOT USED. I. ALL FINISHED FLOOR SURFACES SHALL COMPLY WITH LOCAL CODES, INCLUDING ACCESSIBILITY CODES; ANY CHANGES IN LEVEL FLOOR SURFACE SHALL COMPLY WITH ALL LOCAL CODES, INCLUDING ACCESSIBILITY CODES. 1 2016-026A Seal LEASE LINE; CONFIRM WITH CLIENT & MACY'S PRIOR TO START OF WORK FLAME SPREAD SMOKE DENSITY PLASTIC LAMINATE 80 (BONDED) 95 (BONDED) CARPET 26 - 75 450 OR LESS VINYL TILE 0.45 450 OR LESS LAY-IN CEILING 25 10 FRP 150 245 VINYL BASE 0.45 450 OR LESS NAME: GLENN S. YEAKEL DATE: 07-01-16 REG NO: 20474 JOHNSONITE TANDUS CENTIVA OWNER FURNISHED TRANSITION STRIP STYLE ME003 & ME004 LEVELER. NONE METAL EDGE TROIS(ME003) TRANSITION LVT TO CARPET, 12' LENGTH. METAL EDGE QUATRE (ME004) - LEVELER ONLY (4' STRIPS). INSTALL PER MANUFACTURER RECOMMENDATIONS PRIMER/SEALER LATEX PRIMER / SEALER FOR DRYWALL ICI DULUX PAINTS (502) 969-0181 # 1020-1200PVA NONE ONE (1) COAT REQUIRED PRIMER/SEALER LATEX PRIMER / SEALER FOR METAL ICI DULUX PAINTS (502) 969-0181 DEVGUARD #4120 NONE ONE (1) COAT REQUIRED PRIMER/SEALER LATEX PRIMER / SEALER FOR WOOD ICI DULUX PAINTS (502) 969-0181 WOOD UNDERCOATER NONE ONE (1) COAT REQUIRED CHROME TS-13 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Seal CHROME CHR100 NAME: DATE: WALL LEGEND MATERIAL CLIENT COMMENTS 281 Farmington Avenue Farmington, CT. 06032 CASING T101 HARDWOOD CASING - PAINTED 3/4" x 3/4" HARDWOOD SQUARE NONE FINISH - P104 CASING T102 HARDWOOD CASING - PAINTED 6 3/8" W x 3/4"T PAINTED HARDWOOD CASING NONE FINISH - P104 REG NO: Nextore project Number REV0.7 INTERIOR MATERIALS FIRE RATINGS 07/19/16 Engineer TRANSITION STRIP (LVT TO CARPET) TRANSITION STRIP SEALER B A. # TRIM = FLOOR KEY NOTES Description SUBMIT FOR PERMIT ASSOCIATES INC. MISC. GENERAL NOTES - FINISH PLAN By [email protected] [email protected] FINISH SYMBOL KEY Date 07/07/16 Architect of Record MANDATORY INSTALLATION PER MANUFACTURER'S SPECIFICATIONS. MONOLITHIC INSTALLATION, INSTALL MUST INCLUDE MFG. RECOMMENDED INSTALL METHOD, FLOOR PREP & ADHESIVE INSTALL MUST INCLUDE MANUFACTURER’S RECOMMENDED INSTALLATION METHOD, FLOOR PREP & ADHESIVE. (800) 442-4212; OPTION #1 PLASTIC LAMINATE Mark 1 ARMSTRONG PL100 Revisions: FOR USE ON ROUND COLUMNS ONLY 2' x 2' LAY-IN; 15/16" GRID PLASTIC LAMINATE TRANSITION STRIP XXXX +1 (516) 393-2484 FINISH - P104 [email protected] F +1 (513) 765-6000 p Macy's Store Number: (687) LOCATION: REFERENCE ARCHITECTURE DRAWINGS FOR LOCATIONS & SEAMING. NOTES: PRODUCT IS GLUED TO WALL WITH STANDARD POLYURETHANE ADHESIVE. INSTALL TILES HORIZONTALLY. MODEL/COLOR: MANDALAY, MW-50-H6, 50 WHITE C63 TRANSITION STRIP 1 p 6 Creamery Brook, East Granby, CT 06026 800 347 0550 X864; MOBILE 330 618 1296 [email protected] ROD SEABOLT CDC DISTRIBUTORS (513) 560 - 1040 [email protected] JOHNSONITE CARPET TILE MELAMINE 6 INTERIOR WALLS AND SOFFITS WC105 ALUMINUM 6 2 EXISTING TILE FLOOR TO REMAIN EXISTING TILE FLOOR TO REMAIN TS-4 0 40 8/A F NEW CARPET FINISH TS-4 8/A400 CEILING 2 3 NONE WALLCOVERING C63 MILLWORK 2 INTERIOR ACRYLIC LATEX EXTRA WHITE, SW7006 INTERIOR ACRYLIC LATEX EXTRA WHITE, SW7006 SHERWIN WILLIAMS BASE REMARKS NOTE: ALL SPECS MAY NOT BE USED IN EVERY STORE GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS PAINT (EGGSHELL) (EXTRA WHITE) 2 TS-4 8/A400 ALT P101 6 1 MODEL #/COLOR PAINT WAITING P114 FINISHES N.I.C. P114 EXTG MECH W XTG TAIRS 4000 Luxottica Place, Mason, OH 45040 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 ITEM MARK DESCRIPTION ARCHITECTURAL SPECIFICATIONS / FINISHES W a a FR I A R F EXISTING WALLS TO REMAIN 73052 1 ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title NEW WALL FINISH PLAN PLANK/WOOD GRAIN DIRECTION, TYP. Date 07-01-16 Sheet Drawn By LLB Checked By ANP A103 EXISTING MILLWORK FASCIA TO REMAIN, PROTECT DURING FIXTURE INSTALLATION G.C. TO PROVIDE & INSTALL 1x6 FIRE-RATED WOOD BLOCKING BETWEEN STUDS IN WALL BEHIND GWB, FOR WALL FIXTURE MOUNTING, AT LOCATIONS WHERE FIXTURES ARE SHOWN, TYP.; REMOVE GWB, USE FASTBACK BACKING SYSTEM (CLARK DIETRICH) IF REQUIRED, TO ATTACH TO EXISTING STUDS; PATCH & REPAIR WALL AFTER BLOCKING INSTALLATION ALL EXISTING FINISHES TO REMAIN 9'-612" BOTTOM LIGHT LENS; PROTECT DURING FIXTURE INSTALLATION ALL EXISTING FINISHES TO REMAIN a 4000 Luxottica Place, Mason, OH 45040 p +1 (513) 765-6000 a 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 OPEN 8'-11" C.L. OF BLOCKING Macy's Store Number: (687) 8'-11" C.L. OF BLOCKING 10'-5" EXISTING MILLWORK DISPLAY SURROUND AND BACKWALL TO REMAIN EXISTING MILLWORK FASCIA TO REMAIN, PROTECT DURING FIXTURE INSTALLATION G.C. TO PROVIDE & INSTALL 1x6 FIRE-RATED WOOD BLOCKING BETWEEN STUDS IN WALL BEHIND GWB, FOR WALL FIXTURE MOUNTING, AT LOCATIONS WHERE FIXTURES ARE SHOWN, TYP.; REMOVE GWB, USE FASTBACK BACKING SYSTEM (CLARK DIETRICH) IF REQUIRED, TO ATTACH TO EXISTING STUDS; PATCH & REPAIR WALL AFTER BLOCKING INSTALLATION OPEN Revisions: 17 A200 1 RETAIL 101 2 SCALE: 1/4" = 1'-0" Mark EXISTING DOORWAY TO REMAIN (ACCESS TO ELEVATOR LOBBY AND NEW O.D. OFFICE) EXISTING DOORWAY TO REMAIN RETAIL 101 Date 1 By 07/07/16 Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS SCALE: 1/4" = 1'-0" 1 Architect of Record 1 P114 W W P101 P101 W P101 W P101 P101 W FR I A R W REF: DOOR SCHEDULE FOR DOOR & FRAME FINISHES SE-CL03 SE-CL03 BOH-UP24 BOH-UP24 BOH-UP24 BOH-UP24 BOH-UP24 2'-5" 8" 24" x 24" x 1/8" PLEXI SHIELD TO PROTECT WALL FROM EQUIPMENT ARM SWING; COORDINATE SIZE & LOCATION W/ EQUIPMENT IN FIELD; FASTEN TO STUDS OR TOGGLE BOLT (4) SCREWS V.I.F. SNAP FRAME B WB101 B B 2016-026A 4'-6" 1'-6" WB101 281 Farmington Avenue Farmington, CT. 06032 60" AFF Seal 2'-6" 27" MIN 2'-10" SE-CL02-R ASSOCIATES INC. LCI-GH30 GS-B0H01-R 2'-10" 52" AFF 1'-6" GS-PW94 COAT HOOK; REF: FIXTURE SCHEDULE B WB101 WB101 B WB101 WB101 B REF: 4/A400, TYP. CONTACT LENS 105 4 SCALE: 1/4" = 1'-0" OPTICAL STATION 104 5 SCALE: 1/4" = 1'-0" W P101 CL P114 W 2'-8" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" 1 1 W P114 P101 W P101 W P101 W P101 W P101 W P101 NAME: GLENN S. YEAKEL DATE: 07-01-16 REG NO: 20474 Engineer FIRE EXTINGUISHER; REF: FIXTURE SCHEDULE LCI-GH30 NEW DOOR/SIDELIGHT; REF: DOOR SCHEDULE 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 LCI-GH30 3'-6" 6'-0" ELECTRICAL OUTLET 34" 5'-9" CL CL 1'-6" 1'-6" SE-OD01 _L 34" T.O. SINK 27" MIN 34" W EXAM ROOM 102 7 4'-212" ELEC. OUTLET EQ-119 Seal B 8 P114 SE-OD03 SINK 'SK-7' RE: PLUMBING DRAWINGS EXAM ROOM 102 1 6'-6" EQUIPMENT SE-OD03 SCALE: 1/4" = 1'-0" 4'-9" EQUIPMENT CL SE-OD03 6 1 1 W CONTACT LENS 105 60" AFF 3 WB101 B EXAM ROOM 102 9 SCALE: 1/4" = 1'-0" WB101 B EXAM ROOM 102 SCALE: 1/4" = 1'-0" 10 WB101 B WB101 PRETEST 103 B 11 SCALE: 1/4" = 1'-0" WB101 B WB101 B PRETEST 103/WAITING 106 WB101 12 SCALE: 1/4" = 1'-0" B WB101 B WB101 PRETEST 103 SCALE: 1/4" = 1'-0" NAME: 1 1 1 1 W P101 W P101 3" 78 EXISTING BRICK WALL, TO REMAIN REF: DOOR SCHEDULE FOR DOOR & FRAME FINISHES 512" NEW ELECTRICAL PANEL; REF: ELEC. DWGS. SNAP FRAME LCM-GH16 52" AFF 3'-10" 5'-0" 1'-0" B EQ B WB101 WAITING 106 / CASHWRAP 107 SCALE: 1/4" = 1'-0" 1 X CAT 6 HUBBELL HXJ6BK 1 X DUPLEX (BLACK) GS-PW95 18" x 18" PUMP ACCESS PANEL 14 SILL BELOW EXISTING WINDOW REMOVED PER CONSTRUCTION PLAN EQ WB101 WAITING 106 SCALE: 1/4" = 1'-0" HILTI TOGGLER SNAP AWAY TOGGLE BOLTS. THROUGH PANEL AND GYP. TYP. MIN. OF (4) 9'-6" SE-GH-CHART PROVIDE IN WALL (2) 34" CONDUIT FROM IN-WALL BOX TO 6" ABOVE CEILING NEW STOREFRONT SYSTEM WITHIN EXISTING MASONRY OPENING; REF: DOOR SCHEDULE FUTURE DISPLAY MOUNTING BRACKET 3'-6" AFF LCM-GR32 13 REG NO: DIM. TO LOCATE C.L. P101 B 15 SCALE: 1/4" = 1'-0" IN MILLWORK PANEL: OUTWATER PLASTICS INDUSTRIES INC. OV32 SERIES GROMMET PART#: OV32BK 1-800-631-8375 Nextore project Number 73052 ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title INTERIOR ELEVATIONS BASE CABINET PER ORIGINAL DESIGN GS-PW61_75 - TEMPORARY ELEVATION WB101 OPTICAL STATION 104 IN WALL BEHIND MILLWORK PANEL: ARLTVBU505BL ARLINGTON™ TVBU505BL TWO-GANG RECESSED ELECTRICAL BOX (BLACK) (OR EQUAL BLACK IN COLOR) 5'-63 4" W DATE: EXISTING FASCIA TRIM, TO REMAIN Date 16 VESTIBULE ENTRY SCALE: 1/4" = 1'-0" 17 FIXTURE GS-PW 61_75 SCALE: 1/4" = 1'-0" 07-01-16 Sheet Drawn By LLB Checked By ANP A200 a 4000 Luxottica Place, Mason, OH 45040 p +1 (513) 765-6000 a 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Macy's Store Number: (687) Revisions: Mark Date 1 By 07/07/16 Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS FR I A R Architect of Record ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 2016-026A Seal NAME: GLENN S. YEAKEL DATE: 07-01-16 REG NO: 20474 Engineer EXISTING CEILING REF: RCP FOR TYPE & HEIGHT CEILING REF: RCP FOR TYPE & HEIGHT EXISTING CEILING REF: RCP FOR TYPE & HEIGHT 3 5/8" x 20 GA. METAL STUDS AT 16" O.C. w/ 5/8" TYPE "X" GYP. BD. ONE SIDE; GYP. BD. & STUDS TO UNDERSIDE EXISTING CEILING; CROSS BRACE, AS REQUIRED 5/8" TYPE "X" GYP. BD. TO UNDERSIDE OF EXISTING CEILING; ATTACHED DIRECTLY OVER EXISTING WALL WITH SCREW FASTENERS CEILING REF: RCP FOR TYPE & HEIGHT CEILING REF: RCP FOR TYPE & HEIGHT 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Seal 3 5/8" x 20 GA. METAL STUDS AT 16" O.C. w/ 5/8" TYPE "X" GYP. BD. BOTH SIDES; EXTEND GYP. BD. TO 6" ABOVE FINISHED CEILING HEIGHT ICC - ESR-3064 US ED 7/8" HAT CHANNELS AT 16" O.C. w/ 5/8" TYPE "X" GYP. BD. OVER; GYP. BD. & STUDS TO UNDERSIDE OF EXISTING CEILING 6" TYP. PROVIDE STAGGERED CROSS BRACING; 3‐5/8” 20 GA METAL STUDS FROM TOP OF WALL SECURED TO STRUCTURE ABOVE, AT 24” O.C. MAX O T NOTE: WALLS SHALL BE PLUMB TO WITHIN 1/4" TOP & BOTTOM AT MILLWORK LOCATIONS EXISTING WALL N EXISTING WALL NOTE: WALLS SHALL BE PLUMB TO WITHIN 1/4" TOP & BOTTOM AT MILLWORK LOCATIONS NAME: DATE: REG NO: Nextore project Number 73052 ISSUED FOR: BASE PER ROOM FINISH SCHEDULE; REF: ELEVATIONS BASE PER ROOM FINISH SCHEDULE; REF: ELEVATIONS BASE PER ROOM FINISH SCHEDULE; REF: ELEVATIONS BASE PER ROOM FINISH SCHEDULE; REF: ELEVATIONS Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title WALL TYPES 4 WALL SECTION SCALE: 3/4" = 1'-0" 7/8" FURRED WALL 3 WALL SECTION SCALE: 3/4" = 1'-0" GWB OVER EXISTING WALL 2 WALL SECTION SCALE: 3/4" = 1'-0" TYPICAL CHASE WALL 1 WALL SECTION SCALE: 3/4" = 1'-0" Date TYPICAL FULL HEIGHT WALL 07-01-16 Sheet Drawn By LLB Checked By ANP A300 a 4000 Luxottica Place, Mason, OH 45040 p +1 (513) 765-6000 a 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Macy's Store Number: (687) 1'-7" PARTITION PER CONSTRUCTION PLAN 1" 4 1'-5" +/- 1" FAUCET WALL LINE ACT CLG 3" 1'-54 CASED OPENING TRIM PAINTED "P104" 3 TO TOP OF SINK 2'-10" 2'-3" 2'-5" T 1'-3 " PA N EL H 1 HAND SINK DETAIL 3" SIGN CAB. THK. Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS Architect of Record SCALE: 3/4" = 1'-0" TRANSITION STRIP (TS-4) PER PLANS AND SCHEDULES INSTALL CARPET ON SUBFLOOR TO ALIGN CARPET PILE HEIGHT WITH ADJACENT FINISHED TILE FLOORING B.O. FINISHED CASED OPENING: 9'-6 14" WHEN DOORWAY ABUTTS TILED WALL, 9'-5 14" WHEN NOT ABUTTING TILED WALL. SEE CONSTRUCTION PLAN A101 DOOR TYPES FOR SPECIFIC HEIGHT By ADA SLOPED PANEL SINK BASE WITH REMOVABLE PANEL. PROVIDE CONCEALED SUPPORTS AND FASTENERS AS REQUIRED B.O. SIGN CABINET 8'-0" 11 2" 1" Date 07/07/16 FR I A R ALIGN TO BACKSIDE OF SIGN CABINET: 1/2"THK X 1'-5 1/2"H x 2 1/2"W PAINTED MDF (EQ. THK. FILLER @ EA. SIDE BY GC) FINISH P117 FINISHED OPENING BETWEEN FILLERS SHALL BE 3'-11" HOLD. 1'-1" T102 1'-5 1/4" 1'-512" ILLUMINATED "EYE EXAM" SIGN CABINET BY SIGN CONTRACTOR (BACKSIDE) Mark REV0.1 6" T Revisions: 8" 9" ACT CLG 3" 4 VARIES B.O. O.D. CEILING 10'-0" 2'-6" C.L. A.F.F. IN WALL 6" FIRE-RATED WOOD BLOCKING PROVIDED AND INSTALLED BY G.C. 314" J-BOX ABOVE CEILING @ 10'-6" A.F.F. BY ELECTRICAL CONTRACTOR WITH FLEX CONDUIT WHIP ROUTED IN WALL THRU CASING . SEE ELECTRICAL DRAWINGS 5" 112" ADA, SS DROP-IN SINK ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 2016-026A PORC. TILE ON THIN SET MORTAR BED Seal B WB101 CORNERBEAD GLUE DOWN CARPET PER PLANS AND SCHEDULES SECTION THRU - EYE EXAM SIGN T 8 FLOOR TRANSITION DETAIL SCALE: 6"=1'-0" 683" SCALE: 1 1/2" = 1'-0" WD201 T102 NEW PORCELAIN TILE FLOORING PER PLANS AND SCHEDULES WOOD SURROUND AT LOCATIONS AS INDICATED IN ELEVATIONS; 'WD201' WOOD FINISH, PROVIDED BY TENANT; CUSTOM FIT PROVIDED AND INSTALLED BY MILLWORKER. 2 EXISTING TILE 4" LINE OF SIGN ABOVE NAME: GLENN S. YEAKEL DATE: 07-01-16 REG NO: 20474 Engineer REV 0.1 B TS-10 TRANSITION STRIP PER PLANS AND SCHEDULES B.O. CEILING REF: RCP FOR TYPE & HEIGHT 6 3/8"W x3/4"T TRIM - PAINTED P104 - GLUED & SCREWED. COUNTER SINK SCREWS, FILL AND PREPARE FOR PAINT. PROVIDED AND INSTALLED BY G.C. SEE ELEVATION SHEETS A200 & A201 NON-COMBUSTABLE BLOCKING TS-4 CARPET TO PORCELAIN W W T102 LINE OF EXTG. CONCRETE SLAB 4 7/8" 6 1/2" F.R. PLYWOOD SUBFLOOR-VERIFY HEIGHT REQ'D IN FIELD WB101 CASED OPENING - DETAIL SCALE: 6"=1'-0" 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 ALIGN PARTITION PER CONSTRUCTION PLAN W PT105 THIN SET MORTAR BED PORCELAIN TILE & MORTAR BED OVER GYP. BD. NOTE: PREPARE EXISTING CONCRETE SLAB AS REQUIRED TO PROVIDE LEVEL TRANSITION. ILLUMINATED "LENS CRAFTERS" SIGN CABINET BY SIGN CONTRACTOR J-BOX ABOVE CEILING @ 10'-6" A.F.F. BY ELECTRICAL CONTRACTOR WITH FLEX WHIP ROUTED IN WALL INTO SIGN CABINET. SEE ELECTRICAL DRAWINGS 7 T102 PAINT EXPOSED GYP. BRD. WALL P101 FLOOR TRANSITION DETAIL PORCELAIN TILE TO EXISTING TILE SCALE: 6"=1'-0" 5" 8 T B.O. CEILING ACT @ 10'-0" Seal LINE OF EXISTING CONCRETE SLAB NAME: 3 4" X 34" SQUARE TRIM PROVIDED AND INSTALLED BY GC PAINTED "P104" 3" 4 QUIRK 3 8" B.O. TRIM 9'-6 1/4" W P104 T101 3/4"x3/4" SQUARE TRIM - PAINTED P104 - GLUE & SCREW. COUNTER SINK SCREWS, FILL AND PREPARE FOR PAINT. PROVIDED AND INSTALLED BY GC. SEE ELEVATIONS ON SHEET A200. DATE: REG NO: Nextore project Number 73052 ISSUED FOR: LINE OF MILLWORK EDGE. SEE ELEVATION SHEET A200 FOR DIMENSIONS AND EXTENTS OF MILLWORK 6" RETAIL SIDE O.D. SIDE T GS-PW81 WOOD FINISH. CUSTOM FIT PROVIDED AND INSTALLED BY MILLWORKER. 6" 6" WALL BASE FINISH: P104 OUTLINE OF MILLWORK FIXTURE BELOW. 5/8" GYP. W FINISH BEHIND MILLWORK PORCELAIN TILE & MORTAR BED OVER GYP. BD. PROVIDED AND INSTALLED BY G.C. GS-PW82 WOOD SURROUND ABOVE Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title FINISH FLOOR, SEE SHEET A103 W WD201 4" SEE ELEVATION SHEET A200 FOR DIMENSIONS AND EXTENTS OF TILE 3" 4 1" 4 MISCELLANEOUS SECTIONS & DETAILS Date 5 SECTION THRU - LENS CRAFTERS SIGN SCALE: 1 1/2" = 1'-0" 4 WALL BASE DETAIL SCALE: 6"=1'-0" 1 CUSTOM WOOD MILLWORK - SURROUND SCALE: 6" = 1'-0" 07-01-16 Sheet Drawn By LLB Checked By ANP A400 a 4000 Luxottica Place, Mason, OH 45040 p +1 (513) 765-6000 a 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Macy's Store Number: (687) LOCATION OF EXISTING SQUARE D, 208/120V, 225A PANEL LOCATION OF PROPOSED NEW LENS CRAFTERS PAD Revisions: Mark Date By 07/07/16 Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS 1 Architect of Record 1 FR I A R 3 4 ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 2016-026A Seal NAME: DATE: REG NO: Engineer 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Job# 2016128.00 Seal PLAN NORTH 1 EXISTING FLOOR PLAN - FIRST FLOOR SCALE: 1" = 40'-0" XX KEY NOTES - MECHANICAL/PLUMBING/ELECTRICAL OVERALL PLAN 1. LOCATION OF SANITARY, VENT AND WATER. FIELD VERIFY LOCATION OF PIPING AND CONNECT TO NEW LC MACY'S. CONTRACTOR IS TO SUGGEST ALTERNATE LOCATIONS IF THEY ARE DISCOVERED DURING BIDDING/CONSTRUCTION. 2. PLAN TO DROP THE SANITARY LINE IN ONE OF THESE LOCATIONS TO GET TO THE FIRST FLOOR LEVEL AND CONTINUE TO THE TOILET ROOM DRAINS. VERIFY PIPE ROUTING AND LOCATION IN FIELD. 3. UTILIZE EXISTING 225A PANEL FOR THE 60A FEED TO NEW LOAD CENTER "A" IN THE LENSCRAFTER'S SPACE. VERIFY CURRENT LOAD ON PANEL AND REPORT TO ENGINEER TO CONFIRM PANEL CAPACITY. 4. LOCATION OF EXISTING P.O.S. ROOM. NAME: Michael B. Walsh DATE: 07/07/2016 REG NO: 123816 Nextore project Number MECHANICAL AND ELECTRICAL DRAWING INDEX SHEET MPE100 H100 H200 P100 P200 E100 E200 E201 E300 E400 DESCRIPTION MECHANICAL AND PLUMBING OVERALL BUILDING PLANS HVAC SPECIFICATIONS AND DEMOLITION PLAN HVAC PLANS AND DETAILS PLUMBING SPECIFICATIONS PLUMBING PLANS AND DETAILS ELECTRICAL SPECIFICATIONS, SYMBOLS AND DEMOLITION PLAN ELECTRICAL POWER AND LOW VOLTAGE PLAN AND DETAILS ELECTRICAL LIGHTING PLAN AND DETAILS ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULE CASEWORK DETAILS 73052 ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction MECHANICAL AND PLUMBING OVERALL BUILDING PLANS Title Date 07-01-16 Sheet Drawn By GRD Checked By MTB MPE100 STRUCTURAL ENGINEER. GENERAL CONDITIONS, CODES & STANDARDS I 1. A. 4. 5. 6. 7. 8. SCOPE OF WORK 1. C. A. Mark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y Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS AIR DISTRIBUTION A. XX FR I A R Architect of Record KEY NOTES - MECHANICAL DEMOLITION PLAN 1. REMOVE EXISTING SUPPLY AIR GRILLE OR DIFFUSER AS SHOWN. 2. EXISTING SUPPLY AIR DUCTWORK TO REMAIN. 3. EXISTING RETURN AIR TRANSFER GRILLE. SEE NOTE #3 ON SHEET H200. 4. EXISTING SUPPLY AIR GRILLE OR DIFFUSER TO REMAIN. ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 2016-026A Seal CONTROL WIRING SHALL BE PLENUM RATED CABLE WITH COLOR CODED 18 AWG WIRES (MINIMUM). EXTG VESTIBULE A. TESTING AND BALANCING SHALL NOT BEGIN UNTIL THE SYSTEM HAS BEEN COMPLETED, IS IN FULL WORKING ORDER AND ALL EQUIPMENT START-UP HAS BEEN COMPLETED. ALL HVAC SYSTEMS AND EQUIPMENT SHALL BE PUT INTO FULL OPERATION AND THE OPERATION OF SAME CONTINUED DURING EACH WORKING DAY OF THE TESTING AND BALANCING. N.I.C. B. AN INDEPENDENT "AABC" OR "NEBB" CERTIFIED AIR AND WATER BALANCE CONTRACTOR SHALL TEST AND BALANCE THE SYSTEM AND REPORT RESULTS TO THE ENGINEER TENANT AND THE LANDLORD. 1. 2. 3. 4. 5. ALL WORK SHALL BE DONE UNDER DIRECT SUPERVISION OF THE CERTIFIED BALANCING ENGINEER AND BY QUALIFIED BALANCING TECHNICIANS. METHODS AND FORMS SHALL BE IN ACCORDANCE WITH THE CERTIFICATION AGENCIES RECOMMENDATIONS AND REQUIREMENTS. COMPLY WITH ASHRAE RECOMMENDATIONS PERTAINING TO MEASUREMENTS, INSTRUMENTS, TESTING, ADJUSTING AND BALANCING. ALL QUANTITIES SHALL BE WITHIN 10% OF THE DESIGN VALUES. MECHANICAL CONTRACTOR SHALL PROVIDE ANY SHEAVE CHANGES REQUIRED ON THE HVAC UNIT. TG IRS I.C. EXTG MECH NAME: N.I.C. DATE: EXTG ELEV LOBBY 3 REG NO: N.I.C. 4 4 C. ACCEPTANCE AND CHECK-OUT - GENERAL CONTRACTOR SHALL PROVIDE QUALIFIED PERSONNEL, AT NO ADDITIONAL COST TO THE TENANT, AS MAY BE REQUIRED BY THE ENGINEER FOR THE PURPOSE OF VERIFYING PROPER OPERATION AND INSTALLATION OF THEIR WORK AT THE TIME OF REQUEST FOR ACCEPTANCE. 4 Engineer 4 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Job# 2016128.00 1 1 Seal 2 2 EXTG SALES AREA 2 2 2 N.I.C. 24"X20" SUPPLY DUCT @ 17'-0" A.F.F. 2 METHODS 1. Date 07/07/16 1 COORDINATION 1. E. Revisions: DUCTWORK (ROUND OR RECTANGULAR OR SPIRAL) SHALL BE OF GALVANIZED STEEL CONSTRUCTION AND SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA MANUAL AND THE FOLLOWING PRESSURE / SEAL SCHEDULE: 1.1. SUPPLY AIR DUCTWORK - 2" W.G. POSITIVE PRESSURE, SEAL CLASS B. 1.2. RETURN & EXHAUST DUCTWORK - 2" W.G. NEGATIVE PRESSURE, SEAL CLASS B. 2. ROUND DUCT ELBOWS SHALL BE LONG SWEEP, 1-1/2 TIMES THE CENTERLINE RADIUS UNLESS CLEARANCE IS NOT AVAILABLE AT WHICH TIME MITERED ELBOWS WITH TURNING VANES SHALL BE UTILIZED. 3. RECTANGULAR ELBOWS SHALL BE FURNISHED WITH DOUBLE THICKNESS TURNING VANES. TURNING VANES SHALL BE FASTENED WITH A DOUBLE ROW OF SCREWS. 4. MITERED OFFSETS GREATER THAN 30 DEGREES IN EITHER DIRECTION SHALL NOT BE PERMITTED. 5. CHANGES IN DUCT SIZES SHALL BE MADE BY UNIFORM TAPER SECTION WITH A MAXIMUM INCLUDE ANGLE OF DIVERGENCE OF 15DEGREES. 6. RECTANGULAR BALANCING DAMPERS - RUSKIN MD25 SHALL BE SINGLE BLADE UP TO 6" IN HEIGHT AND 36" IN WIDTH, AND RUSKIN MD35 MULTI-BLADE FOR LARGER SIZES. ALL ROUND BALANCING DAMPERS SHALL BE COMMERCIAL GRADE SINGLE BLADE UP TO 16" IN DIAMETER SHALL INCORPORATE LOCKING TYPE INDICATING ADJUSTMENT. BALANCING DAMPERS SHALL BE INSTALLED IN ALL BRANCH DUCTS OFF MAIN AND ON ALL TAPS OFF DUCTS TO DIFFUSERS UNLESS OTHERWISE NOTED ON DRAWINGS. 7. FINAL CONNECTIONS TO DIFFUSERS MAY BE MADE WITH FLEXIBLE DUCTWORK BUT IT'S USE IS LIMITED TO STRAIGHT HORIZONTAL OR VERTICAL RUNS. ALL CHANGES OF DIRECTION IN AN DUCT SYSTEM (GALVANIZED OR FLEXIBLE) SHALL BE MADE WITH AN APPROPRIATE GALVANIZED ELBOW. MAXIMUM LENGTH OF ANY FLEXIBLE DUCT IS 5'-0". 8. FLEXIBLE DUCTS TO DIFFUSERS: MAXIMUM LENGTH OF FLEXIBLE DUCT TO DIFFUSER TO BE 5'-0". 9. SUPPORT ALL SHEET METAL AND EQUIPMENT FROM ANGLE IRON CONNECTED TO STRUCTURAL STEEL. DO NOT SUSPEND DUCT OR EQUIPMENT FROM METAL DECK OR JOIST BRIDGING. 1. D. +1 (516) 393-2484 1. DOCUMENTS THE DRAWINGS ARE DIAGRAMMATIC, ALL WORK SHALL BE PERFORMED AS INDICATED ON THE DRAWINGS UNLESS EXISTING CONDITIONS OR COORDINATION ISSUES REQUIRE CHANGES. THESE CHANGES SHALL BE MADE WITH NO ADDITIONAL COST TO THE TENANT. 2. ANY INCIDENTAL ITEMS OR LABOR, ETC. NOT INCLUDED IN THE SPECIFICATIONS OR THE DRAWINGS BUT REASONABLY IMPLIED AS NECESSARY FOR THE COMPLETE INSTALLATION OF ALL APPARATUS SHALL BE INCLUDING IN BID. 3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED EVEN THOUGH NOT MENTIONED IN BOTH. 4. IF ERRORS ARE FOUND IN THE DRAWINGS OR SPECIFICATIONS OR DISCREPANCIES OCCUR BETWEEN THE SAME, OR BETWEEN THE FIGURES ON THE DRAWINGS, AND THE SCALE OF SAME OR BETWEEN THE LARGER AND SMALLER DRAWINGS, OR IN THE DESCRIPTIVE MATTER ON THE DRAWINGS SHALL BE REFERRED TO THE TENANT FOR REVIEW AND FINAL DECISION PRIOR TO THE BID DUE DATE. 5. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF EQUIPMENT AND MATERIALS EXACTLY AS SPECIFIED HEREIN. WHERE MORE THAN ONE MANUFACTURER IS MENTIONED ANY ONE MAY BE UTILIZED. SUBSTITUTE MANUFACTURERS MAY BE OFFERED ONLY AS AN ALTERNATE TO THE SPECIFIED EQUIPMENT AND MATERIAL. 5.1. SUBSTITUTIONS 5.1.1. THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE CONTRACT DOCUMENTS ARE FOR THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A BASE LEVEL OF QUALITY. THE GENERAL CONTRACTOR'S BID WILL CONTEMPLATE THE USE OF THE EQUIPMENT AND MATERIALS EXACTLY AS INDICATED. 5.1.2. THE GENERAL CONTRACTOR SHALL SUBMIT FOR APPROVAL, WITH HIS BID QUOTATION, A LIST OF ANY PROPOSED SUBSTITUTIONS OF MATERIALS AND EQUIPMENT FOR THOSE ON WHICH THE ORIGINAL DESIGN WAS BASED. A FULL DESCRIPTION OF ALL PROPOSED SUBSTITUTED ITEMS, THE CHANGE TO THEIR BID PRICE OR OTHER REASONS FOR SUCH SUBSTITUTIONS SHALL ACCOMPANY THE BID. ALL ACCESSORIES, FEATURES, ETC., SUPPLIED WITH THE SUBSTITUTED MANUFACTURER'S PRODUCT SHALL ALSO BE INCLUDED IN THE BID. 5.1.3. IF THE GENERAL CONTRACTOR DOES NOT SUBMIT PROPOSED SUBSTITUTIONS WITH THEIR BID THE TENANT SHALL CONSIDER THE BIDDER TO BE PROPOSING THE MANUFACTURERS AND MODEL NUMBERS SPECIFIED HEREIN AND SHOWN ON THE CONTRACT DRAWINGS. 5.1.4. SUBSTITUTIONS AFTER CONTRACT AWARD SHALL NOT BE PERMITTED. 6. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS. REFER TO EACH SECTION FOR ANY SPECIFIC REQUIREMENTS. +1 (513) 765-6000 p 10"∅ THIS CONTRACT SHALL INCLUDE THE FURNISHING, INSTALLING, CONNECTING, AND OPERATION OF ALL EQUIPMENT WHICH IS A PART OF THE MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS AND AS REQUIRED BY SIMILAR INSTALLATIONS. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK AND WHICH IS USUALLY INCLUDED IN WORK OF A SIMILAR CHARACTER SHALL BE FURNISHED AND INSTALLED UNDER THIS CONTRACT AT NO ADDITIONAL COST TO THE TENANT. GENERAL CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO PROVIDE THE TENANT A COMPLETE, CODE APPROVED AND OPERATIONAL MECHANICAL SYSTEMS. 2. CAREFULLY READ SPECIFICATION FOR ALL PARTS OF THE WORK SO AS TO BECOME FAMILIAR WITH ALL TRADES' WORK SCOPE. CONSULT WITH OTHER TRADES TO INSURE PROPER LOCATIONS AND AVOID INTERFERENCES. ANY CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE TENANT BEFORE WORK IS COMMENCED. 3. ALL CONTRACTORS SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO COMPARE THEM WITH THE DRAWINGS AND SPECIFICATIONS, NOTE THE EXISTING CONDITIONS AND OTHER WORK THAT WILL BE REQUIRED, AND THE NATURE OF THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. NO ALLOWANCE SHALL BE MADE TO ALL CONTRACTORS BY REASON OF THIS FAILURE TO HAVE MADE SUCH EXAMINATION OR OF ANY ERROR ON HIS PART. 4. ALL EXISTING UTILITY AND MECHANICAL SERVICES SHALL BE FIELD VERIFIED. CORRECTIONS TO THE DESIGN AND INSTALLATION SHALL BE MADE WITHOUT ADDITIONAL COST TO THE TENANT. 5. THIS GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE THE OPENINGS WITH THE GENERAL TRADES CONTRACTOR. THE FINAL LOCATIONS AND SIZES OF ALL DUCT AND LOUVER OPENINGS SHALL BE PROVIDED BY THIS CONTRACTOR. 6. THIS CONTRACT SHALL ALSO INCLUDE ALL LABOR, MATERIALS AND MISCELLANEOUS EXPENSES REQUIRED FOR ALL REQUIRED MECHANICAL DEMOLITION OF THE EXISTING AREAS BEING RENOVATED. 6.1. ALL ABOVE GROUND SERVICES SHALL BE REMOVED BACK TO THEIR RESPECTIVE MAIN AND CAPPED OR IF THE MAIN IS NOT REQUIRED, THE MAIN SHALL BE REMOVED IN IT'S ENTIRETY. 6.2. COORDINATE ALL DEMOLITION WITH THE ARCHITECTURAL DOCUMENTS AND THE ARCHITECT AND THE TENANT'S GENERAL REQUIREMENTS. 7. ALL WORK INCLUDING, BUT NOT LIMITED TO PARTS, MATERIAL, EQUIPMENT AND LABOR SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE BY THE ENGINEER AND TENANT. WHERE AN EQUIPMENT MANUFACTURER HAS A WARRANTY THAT EXCEEDS ONE YEAR, THAT WARRANTY PERIOD SHALL APPLY TO THIS PROJECT. p 6 Creamery Brook, East Granby, CT 06026 Macy's Store Number: (687) 12"∅ B. 2. 3. INSTALLATION SHALL CONFORM TO THE MANUFACTURER'S RECOMMENDATIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. CLEAN AND DRY SURFACES PRIOR TO INSULATING. EXTEND INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, HANGERS AND SIMILAR PENETRATIONS. INSULATION JACKET AND FITTING COVER MUST BE PLENUM RATED. IT IS ESSENTIAL THAT THE INTEGRITY OF THE VAPOR-BARRIER BE MAINTAINED. SEAL ALL PENETRATIONS OF THE VAPOR BARRIER BY STAPLES, HANGERS OR WHERE OTHERWISE DAMAGED. MAINTAIN ACCESS TO BALANCING DAMPERS AND VALVES. INSULATION SHALL BE BY OWENS-CORNING, KNAUF, OR MANVILLE. ALL DUCTWORK AND PIPING SHALL BE INSULATED PER REQUIREMENTS OF ASHRAE 90.1, INTERNATIONAL ENERGY CONSERVATION CODE (IECC), NFPA, AND LOCAL CODES. THE FIRST 10 FEET OF RETURN DUCTS SHALL BE INTERNALLY LINED FOR ACOUSTICAL ATTENUATION. OUTSIDE AIR DUCTWORK AND DUCTWORK IN UNCONDITIONED SPACES SHALL ALWAYS BE INSULATED WITH EXTERNAL INSULATION. PIPING SYSTEMS ALWAYS REQUIRING INSULATION INCLUDES, BUT IS NOT LIMITED TO, CONDENSATE, REFRIGERANT, CHILLED WATER, HEATING HOT WATER, CONDENSER WATER, AND STEAM. INTERNALLY INSULATED DUCTS SHALL HAVE 1 INCH THICK, 1-1/2 LB DENSITY ACOUSTICAL INSULATION (AIR SIDE BLACK COATED TO MEET NFPA). INSULATION SHALL BE INSTALLED PER THE REQUIREMENTS OF THE SMACNA GUIDE AND THE MANUFACTURER'S RECOMMENDATIONS. DUCT SIZES NOTED ON DRAWING ARE INSIDE CLEAR DIMENSIONS. INSULATION WRAP SHALL BE FIBERGLASS, FOIL BACKED WRAPPING. WHERE DUCTS OR PIPING IS EXPOSED, AND REQUIRES INSULATION, PROVIDE FIBERBOARD RIGID INSULATION AND PAINT. PAINT COLOR SHALL BE COORDINATED WITH THE ARCHITECTURAL DRAWINGS, LANDLORD, AND TENANT. WHERE DUCTS OR PIPES ARE OUTSIDE THE BUILDING, AN ALUMINUM JACKET SHALL BE PROVIDED AND INSTALLED OVER THE INSULATION, AND SEALED WEATHERTIGHT. 10"∅ 4. 1. 4000 Luxottica Place, Mason, OH 45040 a A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 8"∅ 3. GENERAL 8"∅ 2. GENERAL CONDITIONS OF THE CONTRACT FOUND IN THE ARCHITECTURAL DRAWINGS, GENERAL AND SPECIAL CONDITIONS OF THE AMERICAN INSTITUTE OF ARCHITECTS (AIA) (NSPE)(NEC) AND ANY OF THE TENANT'S GENERAL REQUIREMENTS SHALL APPLY UNLESS NOTED OTHERWISE. REFER TO THE GENERAL CONDITIONS ON THE ARCHITECTURAL DOCUMENTS AND THE GENERAL AND SPECIAL CONDITIONS OF THE AIA FOR ADDITIONAL REQUIREMENTS REGARDING; SAFETY, COORDINATION & COOPERATION, WORKMANSHIP, PROTECTION, CUTTING AND PATCHING, DAMAGE TO OTHER WORK, PRELIMINARY OPERATIONS, STORAGE, ADJUSTMENTS, CLEANING, ETC. ALL WORK SHALL BE IN CONFORMANCE WITH ALL LOCALLY ENFORCED, FEDERAL, STATE AND LOCAL CODES AND ORDINANCES INCLUDING ANY SPECIAL THE TENANT REQUIREMENTS IN ADDITION TO THOSE SPECIFIED. GENERAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS. 8"∅ A. a NAME: Michael B. Walsh DATE: 07/07/2016 REG NO: 123816 Nextore project Number 73052 2 ISSUED FOR: EQUIPMENT, PIPING, DUCTWORK, ETC. SHALL NOT BE SUPPORTED FROM ANY CEILINGS, OTHER PIPING, CONDUIT OR DUCTWORK, ROOF DECK, OR JOIST BRIDGING. ITEMS SHALL BE SUPPORTED FROM ACCEPTABLE STRUCTURAL BUILDING COMPONENTS AS DETERMINED BY THE ARCHITECT AND Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction HVAC SPECIFICATIONS AND DEMOLITION PLAN Title PLAN NORTH 1 MECHANICAL DEMOLITION PLAN SCALE: 1/4" = 1'-0" Date 07-01-16 Sheet Drawn By GRD Checked By MTB H100 TAG SERVICE MOUNTING SUPPLY AIR SUPPLY AIR MATCH CEILING MATCH CEILING R1 RETURN AIR R2 RETURN AIR S1 S2 MFR MODEL No. MODULE SIZE FINISH DUCT SIZE CROSS REFERENCE TMS 24" X 24" TITUS TMS 12" X 12" MATCH CEILING TITUS 50F 24" X 24" STD. WHITE FINISH MATCH CEILING TITUS 50F 12" X 12" STD. WHITE FINISH GENERAL NOTES - APPLIES TO ALL SHEETS SUPPLY AIR DIFFUSER - ARROWS INDICATE PATTERN. NO PATTERN SHOWN EQUALS 4-WAY. OR AS NOTED NOTES STD. WHITE FINISH STD. WHITE FINISH TITUS HVAC SYMBOLS A. RETURN AIR GRILLE 1 1 12"Ø ROUND DUCTWORK. DIAMETER IN INCHES. 20x12 DIFFUSER/GRILLE LABEL: A - TYPE/DESIGNATION B - NECK SIZE (INCHES) C - AIRFLOW (CFM) B C A B. RECTANGULAR DUCTWORK. SIZE IN INCHES, FIRST NUMBER IS SIDE SHOWN. 1. PROVIDE NECK SIZE TO MATCH SUPPLY DUCTWORK ON DRAWINGS. POINT OF CONNECTION - NEW TO EXISTING G.C. SHALL NOTIFY TENANT, ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR INCREASE THE SCOPE OF WORK FROM WHAT IS DESCRIBED IN THE DOCUMENTS. D. G.C. SHALL BE RESPONSIBLE FOR ALL CUTTING/PATCHING RELATED TO THEIR WORK. E. IF SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM, CONSTRUCTION MATERIALS ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED TYPE PER NFPA 70. F. COORDINATE LOCATION AND ELEVATION OF MECHANICAL WORK WITH ALL DUCTWORK, LIGHT FIXTURES, AND OTHER CEILING BUILT-IN FIXTURES. CONTACT ENGINEER OR ARCHITECT IMMEDIATELY SHOULD ANY CONFLICT ARISE. SHEET KEYNOTE REFERENCE G. KEY NOTES # 1. RETAIL AREA OPEN TO MACY'S HVAC SYSTEM. NO WORK REQUIRED IN THIS AREA. 2. EXISTING SUPPLY AIR DUCTWORK TO REMAIN. 3. EXISTING RETURN AIR TRANSFER GRILLE TO REMAIN IF LOCATED ABOVE NEW FINISHED CEILING IN RETURN AIR PLENUM. IF NOT, CONTRACTOR SHALL RELOCATE TRANSFER GRILLE TO ABOVE NEW FINISHED CEILING. 4. EXISTING SUPPLY AIR GRILLE OR DIFFUSER TO REMAIN. 5. CONNECT NEW SUPPLY AIR DUCTWORK TO EXISTING STORE SUPPLY AIR DUCTWORK AS INDICATED. 6. PROVIDE DAMPERS PER DETAIL C/H200. 7. PROVIDE DUCT TAKE OFFS PER DETAIL. HIGH EFFICIENCY FITTINGS SHALL BE USED. SEE DETAIL A/H200 8. CONTRACTOR SHALL VERIFY THAT A MINIMUM OF ONE 24X24 RETURN AIR OPENING TO THE CEILINGS RETURN AIR PLENUM IS PROVIDED. IF ONE IS NOT PROVIDED, THE CONTRACTOR SHALL PROVIDE OPENING AS INDICATED. ECCENTRIC REDUCER RECTANGULAR DUCTWORK ROUND DUCTWORK BALANCING DAMPER BALANCING DAMPER 45° LATERAL FITTING RECTANGULAR TO ROUND "BUCKLEY FITTING" RECTANGULAR DUCTWORK NO PVC PIPING ALLOWED IN PLENUM AREAS. I. DUCT SIZES INDICATED REPRESENT CLEAR INTERIOR SHEET METAL DIMENSIONS. J. ALL DUCTWORK CONCEALED ABOVE CEILINGS, AND ALL OUTSIDE AIR DUCTS, SHALL BE EXTERNALLY INSULATED. IF DUCTWORK IS RUN IN A NON-CONDITIONED SPACE ALL DUCTWORK MUST BE INSULATED WITH 2" FIBERGLASS INSULATION AND VAPOR BARRIER. K. BRANCH DUCTS SERVING DIFFUSERS SHALL BE SIZED TO MATCH DIFFUSER NECK SIZE INDICATED. L. ALL ROUND DUCT ELBOWS SHALL BE LONG SWEEP, 1-1/2 TIMES THE CENTERLINE RADIUS. M. G.C. MUST REPLACE ALL AIR FILTERS IN HVAC UNITS WITH NEW CLEAN FILTERS BEFORE AIR BALANCING AND PRIOR TO FINAL TURNOVER TO TENANT. N. IT IS THE G.C.'S RESPONSIBILITY TO ENSURE THAT THE MECHANICAL COMPONENTS ARE INSTALLED AT LOCATIONS AND ELEVATIONS WHICH MAKE THEM READILY AND SAFELY ACCESSIBLE FOR ROUTINE MAINTENANCE WITHOUT REQUIRING ANY EXTRAORDINARY MEASURES. O. THE TENANT RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS AND SPECIFICATIONS. SHOULD THE TENANT FIND CORRECTIVE WORK NECESSARY, HE WILL NOTIFY G.C. OF SUCH WORK IN WRITING AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK IS DEEMED TO BE NECESSARY, THE COST OF REINSPECTIONS WILL BE BORNE BY THE G.C. IF WORK IS REQUIRED BY TENANT IN ORDER TO IMPROVE, CHANGE OR CORRECT AIR CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART MALFUNCTION, WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE STORE, G.C. SHALL BE DIRECTED BY TENANT TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES EVIDENT THAT THE G.C. CAN NOT ACCOMPLISH THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE, THE TENANT MAY AT HIS DISCRETION TAKE OVER SUCH WORK AND BACK CHARGE THE G.C. FOR ANY CORRECTIVE WORK THAT WAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND/OR ADHERENCE TO PLANS AND SPECIFICATIONS. DUCTWORK SHALL NOT BE ROUTED OVER ELECTRIC PANELS AND TRANSFORMER. Q. INSULATE ALL DUCTWORK PER APPLICABLE ENERGY / MECHANICAL CODE - MOST RESTRICTIVE TO GOVERN. EXTG VESTIBULE N.I.C. p +1 (513) 765-6000 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Macy's Store Number: (687) Revisions: Mark Date By 07/07/16 Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS 1 Architect of Record ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 2016-026A Seal NAME: BALANCING DAMPER S-1 150 CONICAL FITTING TG IRS DUCT BRANCH TAKE-OFF DETAIL I.C. S-1 125 R-2 150 INSULATED RIGID ROUND DUCTWORK. INSULATION TO HAVE FOIL FACING (TYP.) INSULATED FLEX. DUCT (5 FEET MAX.) 1'' DUCT LINER LINE WITH 1" INSUL. GALVANIZED SHEET METAL DUCTWORK SHALL BE 1.5 x R, INSULATED 90 DEGREE SHEET METAL ELBOW VOLUME DAMPER TO BE WITHIN 12" OF MAIN DUCT SEE DETAIL B/H200 4 CONTACT EXIST LENS 150 GS-CL02-R 7 N.I.C. CEILING DIFFUSER HVAC DETAIL NOTES: 1 Seal 5 6 6 7 RETAIL SEE HVAC DRAWINGS FOR DUCT SIZES 101 8 EXTG SALES AREA N.I.C. 2 OPTICAL STATION 2 2 10"∅ 2 10"∅ 2 8"∅ SCALE: NONE 1 8"∅ C SCALE: NONE DUCT CONNECTION DETAIL 8"∅ PLENUM RETURN BOX DETAIL 4 104 2 R SHALL EQUAL OR BE GREATER THAN 1/3W. NAME: Michael B. Walsh DATE: 07/07/2016 REG NO: 123816 Nextore project Number 24"X20" SUPPLY DUCT @ 17'-0" A.F.F. 73052 ISSUED FOR: 12"∅ W R SHALL EQUAL OR BE GREATER THAN W. 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Job# 2016128.00 S-1 125 5 6 4 106 R-2 125 5 4 WAITING 8" DIA 6 N.I.C. 4 SEE DETAIL B/H200 105 NEW STOCK 1 R-2 250 SK3 DRAW BAND (TYP.) ACOUSTICAL CEILING 1. 8" DIA SUPPORT TO STRUCTURE ABOVE (TYP.) Engineer EXTG ELEV LOBBY 3 107 8" DIA HIGH EFFICIENCY FITTING N.I.C. CASHWRAP SCALE: NONE REG NO: EXTG MECH S-1 125 8" DIA RECTANGULAR TO RECTANGULAR R 4000 Luxottica Place, Mason, OH 45040 DATE: SUPPLY AIR DUCT, INSULATE PER SPEC. B a a ROUND DUCTWORK 8" DIA A P. 4" BRANCH DUCT HEIGHT DIMENSION 2" LESS THAN MAIN DUCT HEIGHT DIMENSION BALANCING DAMPER MOUNTING OF ALL EQUIPMENT, DUCTWORK AND PIPING MUST BE DONE PER BUILDING GUIDELINES AND LOCAL CODES AND INDUSTRY STANDARDS. COORDINATE INSTALLATION OF EQUIPMENT SUPPORT WITH BUILDING MANAGER AND NEXTORE REPRESENTATIVE. H. VARIES 2" MINIMUM COLLAR EXISTING MECHANICAL INFORMATION IS BASED ON LIMITED EXISTING BUILDING DRAWINGS AND FIELD WORK. THE G.C. SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED FOR REVISIONS TO THE DESIGN TO CORRECT FOR EXISTING CONDITIONS NOT AS INDICATED ON THE PLANS. C. MANUAL VOLUME DAMPER # THE CONTRACT DOCUMENTS REFLECT A SYSTEM DESIGNED AROUND SPECIFIC REFERENCE PRODUCTS, THE SELECTION OF WHICH HAS IMPACTED THE DESIGNS OF OTHER TRADES. IF ALTERNATE MANUFACTURERS ARE SUBMITTED OR BID, IT IS THE RESPONSIBILITY OF THIS G.C. TO COORDINATE ALL DIFFERENCES AND IMPACTS WITH ALL TRADES PRIOR TO BID, INCLUDING COSTS ASSOCIATED WITH REQUIRED CHANGES TO OTHER TRADES. NO EXTRAS WILL BE ALLOWED FOR CHANGES REQUIRED TO OTHER TRADES IF ALTERNATE EQUIPMENT IS BID OR INSTALLED AT THE G.C.'S OPTION. FR I A R GRILLE, REGISTER AND DIFFUSER SCHEDULE R SHALL EQUAL OR BE GREATER THAN 1/6W. 2 Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title HVAC PLANS AND DETAILS STANDARD RADIUS ELBOW D RADIUS ELBOW DETAIL SCALE: NONE PLAN NORTH 1 HVAC DUCTWORK PLAN SCALE: 1/4" = 1'-0" Date 07-01-16 Sheet Drawn By GRD Checked By MTB H200 GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS. PLUMBING EQUIPMENT SCHEDULE DESCRIPTION SINK: CLF-ADA-10 FAUCET: JUST # J-981 SK-7 30" SINK FOR BOH-SU30 T / PC ELKAY IWH-1A IWH-1B TANKLESS WATER HEATER MOUNTED BELOW SINKS IN CABINET. PC / PC EEMAX MODEL #SP2412 SINGLE POINT, 120 VOLT, 1 PHASE, 60 HZ, 2.4 KW, 33° TEMPERATURE RISE. SEP-1 SEWAGE EJECTION PUMP AND RESERVOIR PC / PC SANIFLO SANIVITE SELF CONTAINED SEWAGE EJECTOR PUMP AND BASIN. CORD AND PLUG CONNECTION TO GFI OUTLET REQUIRED. 120V, 4.5 AMPS, 3/10 HP. UNIT IS APPROXIMATELY15" X 8" X 11" HIGH (WITHOUT PIPING). PROVIDE SANIALARM WITH UNIT AND INSTALL. PURCHASE PUMP FROM SELECTED VENDOR: SANIFLO, DISTRIBUTER TO CONTACT: THE DISTRIBUTION POINT (ALABAMA). CONTACT NAME: ROB FOSTER; CONTACT PHONE: 1-866-837-2550; CONTACT EMAIL: [email protected] OR [email protected] T / PC GENERAL CONDITIONS, CODES & STANDARDS 2. 3. 4. GENERAL CONDITIONS OF THE CONTRACT FOUND IN THE ARCHITECTURAL DRAWINGS, GENERAL AND SPECIAL CONDITIONS OF THE AMERICAN INSTITUTE OF ARCHITECTS (AIA) (NSPE)(NEC) AND ANY OF THE TENANT'S GENERAL REQUIREMENTS SHALL APPLY UNLESS NOTED OTHERWISE. REFER TO THE GENERAL CONDITIONS ON THE ARCHITECTURAL DOCUMENTS AND THE GENERAL AND SPECIAL CONDITIONS OF THE AIA FOR ADDITIONAL REQUIREMENTS REGARDING; SAFETY, COORDINATION & COOPERATION, WORKMANSHIP, PROTECTION, CUTTING AND PATCHING, DAMAGE TO OTHER WORK, PRELIMINARY OPERATIONS, STORAGE, ADJUSTMENTS, CLEANING, ETC. ALL WORK SHALL BE IN CONFORMANCE WITH ALL LOCALLY ENFORCED, FEDERAL, STATE AND LOCAL CODES AND ORDINANCES INCLUDING ANY SPECIAL TENANT REQUIREMENTS IN ADDITION TO THOSE SPECIFIED. GENERAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS. SCOPE OF WORK 1. ONLY MAJOR EQUIPMENT IS SHOWN ON THE DRAWINGS. THE PLUMBING CONTRACTOR SHALL BID AND CONSTRUCT A COMPLETE AND OPERATIONAL SYSTEM. MISCELLANEOUS EQUIPMENT REQUIRED TO COMPLETE THE WORK IS IN THE PLUMBING CONTRACTOR'S SCOPE - ASSUME NO WORK OR EQUIPMENT IS PROVIDED BY OTHERS UNLESS STATED AS SUCH. 2. DURING BIDDING: 2.1.VERIFY THE EXISTING CONDITIONS AND COMPENSATE FOR ANY VARIATIONS IN THE SCOPE AS A RESULT. 2.2. REVIEW THE DRAWINGS AND SPECIFICATIONS OF OTHER TRADES. WHERE THERE IS UNCERTAINTY ABOUT WHICH TRADE PROVIDES THE WORK, CONSULT WITH THE GENERAL CONTRACTOR FOR CLARIFICATION. 2.3. WHERE THERE IS A CONFLICT THAT CANNOT BE RESOLVED BY THE GENERAL CONTRACTOR, ADVISE ENGINEER PROMPTLY FOR A RESOLUTION. DO NOT PROVIDE WORK WHEN THERE IS UNCERTAINTY ON WHAT WORK IS TO BE PERFORMED. 3. THE DRAWINGS ARE GENERATED BY COMPETENT PROFESSIONALS, HOWEVER, THERE MAY STILL BE ERRORS OR AREAS OF CONFUSION. AS PART OF THE BIDDING PROCESS, REPORT TO THE TENANT ANY ERRORS OR UNCLEAR DIRECTIONS THAT YOU HAVE IDENTIFIED. 4. REVIEW LANDLORD CONSTRUCTION CRITERIA 5. ALL WORK INCLUDING, BUT NOT LIMITED TO PARTS, MATERIAL, EQUIPMENT AND LABOR SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE BY THE ENGINEER AND TENANT. WHERE AN EQUIPMENT MANUFACTURER HAS A WARRANTY THAT EXCEEDS ONE YEAR, THAT WARRANTY PERIOD SHALL APPLY TO THIS PROJECT. C. DOCUMENTS 1. THE DRAWINGS ARE CONSTRUCTION DOCUMENTS, NOT SHOP DRAWINGS. THEY ARE NOT CREATED TO SHOW ALL DETAILS REQUIRED FOR A COMPLETE INSTALLATION BUT INSTEAD TRUST THAT THE INSTALLING CONTRACTOR IS EXPERIENCED AND LICENSED AS A MASTER PLUMBER (OR SIMILAR DEFINITION DEPENDING ON THE JURISDICTION). 2. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF EQUIPMENT AND MATERIALS EXACTLY AS SPECIFIED HEREIN. WHERE MORE THAN ONE MANUFACTURER IS MENTIONED ANY ONE MAY BE UTILIZED. SUBSTITUTE MANUFACTURERS MAY BE OFFERED ONLY AS AN ALTERNATE TO THE SPECIFIED EQUIPMENT AND MATERIAL. 2.1.SUBSTITUTIONS 2.1.1. THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE CONTRACT DOCUMENTS ARE FOR THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A BASE LEVEL OF QUALITY. THE GENERAL CONTRACTOR'S BID WILL CONTEMPLATE THE USE OF THE EQUIPMENT AND MATERIALS EXACTLY AS INDICATED. 2.1.2. THE GENERAL CONTRACTOR SHALL SUBMIT FOR APPROVAL, WITH HIS BID QUOTATION, A LIST OF ANY PROPOSED SUBSTITUTIONS OF MATERIALS AND EQUIPMENT FOR THOSE ON WHICH THE ORIGINAL DESIGN WAS BASED. A FULL DESCRIPTION OF ALL PROPOSED SUBSTITUTED ITEMS, THE CHANGE TO THEIR BID PRICE OR OTHER REASONS FOR SUCH SUBSTITUTIONS SHALL ACCOMPANY THE BID. ALL ACCESSORIES, FEATURES, ETC., SUPPLIED WITH THE SUBSTITUTED MANUFACTURER'S PRODUCT SHALL ALSO BE INCLUDED IN THE BID. 2.1.3. IF THE GENERAL CONTRACTOR DOES NOT SUBMIT PROPOSED SUBSTITUTIONS WITH THEIR BID THE TENANT SHALL CONSIDER THE BIDDER TO BE PROPOSING THE MANUFACTURERS AND MODEL NUMBERS SPECIFIED HEREIN AND SHOWN ON THE CONTRACT DRAWINGS. 2.1.4. SUBSTITUTIONS AFTER CONTRACT AWARD SHALL NOT BE PERMITTED. 3. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS. REFER TO EACH SECTION FOR ANY SPECIFIC REQUIREMENTS. D. CONSTRUCTION COORDINATION 1. 2. 3. 4. 5. 6. 7. DURING BIDDING YOU VISITED THE SITE. WORK WITH THE GENERAL CONTRACTOR TO COORDINATE ANY CONFLICTS WITH EXISTING CONDITIONS. THIS WORK SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE TENANT. IN THE EVENT THE WORK OF TWO OR MORE TRADES INTERFERE WITH EACH OTHER AND THIS WAS NOT IDENTIFIED DURING BIDDING, AND A DEVIATION FROM DESIGN IS NECESSARY, NEITHER WORK SHALL PROCEED UNTIL THE TENANT HAS BEEN NOTIFIED OF THE CONFLICT AND THEY HAVE RENDERED A DECISION AS TO WHAT CHANGES SHOULD BE MADE AND NO ADDITIONAL COSTS WILL BE ACCEPTED. GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE GENERAL CONTRACTOR CAUSING THE DAMAGE. IT IS ESSENTIAL THAT ALL WORK AT THE PROJECT BE DONE AS SUCH TIME AND IN SUCH MANNER AS NOT TO INTERFERE WITH THE NORMAL OPERATIONS OF THE FACILITY. A WORK SCHEDULE SHALL BE ARRANGED WITH THE TENANT TO FACILITATE WORK WITH A MINIMUM OF INTERFERENCE WITH THE TENANT'S OPERATIONS. AREAS TO BE USED FOR STORAGE SHALL BE ONLY AS DIRECTED BY THE TENANT. ALL STORED MATERIAL SHALL BE RELOCATED OR REMOVED FROM THE SITE AS DIRECTED BY THE TENANT. DAILY, AND AT THE COMPLETION OF THE WORK, EACH GENERAL CONTRACTOR SHALL REMOVE ALL EXCESS MATERIALS AND DEBRIS CAUSED BY HIS WORK. UPON COMPLETION OF EACH GENERAL CONTRACTOR'S WORK, CONDITIONS OF THE SPACE(S) SHALL BE THE SAME AS FOUND PRIOR TO COMMENCEMENT OF THE WORK. FAILURE TO DO SO MAY RESULT IN THE TENANT'S EMPLOYMENT OF A SEPARATE SERVICE TO OBTAIN THIS CONDITION AND REDUCING THE FACTOR'S CONTRACT AMOUNT BY THE COST OF SUCH A SERVICE. EACH GENERAL CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO OTHER WORK CAUSED BY HIS WORK OR THROUGH THE NEGLECT OF HIS, OR HIS SUB-TRADE'S PERSONNEL. ALL PATCHING, REPAIRING, REPLACEMENT AND PAINTING, ETC. SHALL BE DONE AS DIRECTED BY THE TENANT BY THE CRAFTSMEN OF THE TRADES INVOLVED. THE COSTS OF SUCH WORK SHALL BE PAID BY THE CONTRACTOR CAUSING THE DAMAGE. JUST SINKS (847) 678-5150 SINK: LLVR2117, STRAINER: 1135, FAUCET: DELTA 101DST GC TO MAKE FINAL CONNECTIONS. INSTALL MIXING VALVE BELOW FIXTURE, CONNECT TO SUPPLY PIPING AT FIXTURE, SET WATER TEMP. @ 110° F. EQUIPMENT, PIPING, DUCTWORK, ETC. SHALL NOT BE SUPPORTED FROM ANY CEILINGS, OTHER PIPING, CONDUIT OR DUCTWORK, ROOF DECK, OR JOIST BRIDGING. ITEMS SHALL BE SUPPORTED FROM ACCEPTABLE STRUCTURAL BUILDING COMPONENTS AS DETERMINED BY THE ARCHITECT AND STRUCTURAL ENGINEER. +1 (513) 765-6000 p +1 (516) 393-2484 Macy's Store Number: (687) *SELECT 1-HOLE DRILLING CONFIGURATION. G.C. TO MAKE FINAL CONNECTIONS. INSTALL MIXING VALVE BELOW FIXTURE, CONNECT TO SUPPLY PIPING AT FIXTURE, SET WATER TEMP. @ 110° F IF REQUIRED. Revisions: Mark PART 2 - MATERIALS By Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS Architect of Record A. GENERAL PROVIDE STOP VALVES AT EVERY FIXTURE ON BOTH HOT AND COLD WATER SUPPLY LINES. VALVES, ESCUTCHEONS, FITTINGS, ETC. MUST BE CHROME PLATED. WHERE EXPOSED, CHROME PLATED PIPE IS TO BE USED. 2. ANYTHING NOT NOTED AS EXISTING IS TO BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT. 3. INSULATION SHALL BE BY OWENS-CORNING, KNAUF, OR MANVILLE. 3.1.ALL ABOVE GROUND PIPING SHALL BE INSULATED WITH FIBERGLASS PIPING INSULATION WITH AN ALL SERVICE JACKET AND SELF SEALING LAP (ASJ/SSL). 3.1.1. DOMESTIC HOT AND COLD WATER PIPING UP TO 3/4 INCH DIAMETER - 1/2 INCH THICK. 3.2. FITTINGS AND VALVES SHALL BE INSULATED WITH PRE-MOLDED FIBERGLASS FITTINGS AND COVERED WITH A PRE-FORMED PVC FITTING COVER. 4. ALL FIXTURES AND EQUIPMENT NOT SPECIFIED HERE-IN ARE BEING PROVIDED BY OTHERS. THIS GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ROUGHING IN ALL SERVICES FOR ALL EQUIPMENT WHETHER PROVIDED BY THIS GENERAL CONTRACTOR OR OTHERS. GENERAL CONTRACTOR SHALL COORDINATE HIS INSTALLATION WITH THE APPROPRIATE EQUIPMENT SUPPLIER FOR PROPER ROUGH IN INFORMATION AND SHALL REVISE THE DESIGN AS REQUIRED TO MATCH THE EQUIPMENT BEING SUPPLIED. THIS GENERAL CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO CONNECT ALL FIXTURES TO THE PLUMBING SYSTEMS INCLUDING BUT NOT LIMITED TO; ALL WATER CONNECTIONS FROM APPROPRIATE STOP OR VALVE, ALL DIRECT SANITARY CONNECTIONS, ALL WASTE CONNECTIONS TO SINKS, ETC. 5. FIRE STOPPING - REFER TO ARCHITECTURAL DRAWINGS FOR WALL TYPE AND UL CONSTRUCTION DESIGN NUMBER. FOR RATED MASONRY WALL AND FLOOR ASSEMBLIES, PROVIDE A UL APPROVED THROUGH-PENETRATION FIRE STOP SYSTEM NUMBER C-AJ-1175. FOR RATED GYPSUM BOARD ASSEMBLIES, PROVIDE A UL APPROVED THROUGH-PENETRATION FIRE STOP SYSTEM NUMBER W-L-1003. 6. ABOVE GROUND WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON NO-HUB PIPE WITH STAINLESS STEEL BANDED JOINTS AND BE HUNG PER C.I.S.P.I. REQUIREMENTS OR SCHEDULE 40 DWV PVC PIPING AND FITTINGS WITH SOLVENT WELDED JOINTS. 7. ABOVE GROUND WATER PIPING, 3" AND SMALLER, SHALL BE TYPE "L" HARD DRAWN COPPER PIPE WITH WROUGHT COPPER FITTINGS AND 95-5 SOLDERED JOINTS. AS AN ALTERNATE THE GENERAL CONTRACTOR MAY UTILIZE COPPER PRESS FITTINGS (PROPRESS SYSTEM) AS MANUFACTURED BY VIEGA. FITTINGS SHALL CONFORM TO THE MATERIAL AND SIZING REQUIREMENTS OF ASME B16.18 OR ASME B16.22. O-RINGS FOR FITTINGS SHALL BE EDPM. INSTALLATION OF FITTINGS SHALL CONFORM TO CODE AND THE MANUFACTURER'S SPECIFICATIONS/REQUIREMENTS. WATER PIPING JOINTS BETWEEN DIFFERENT MATERIALS SHALL BE PER THE LOCALLY ENFORCED PLUMBING CODE SECTION 605.22. Date 07/07/16 1 1. XX KEY NOTES - PLUMBING AND FIRE PROTECTION DEMOLITION PLAN ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 1. EXISTING HOT WATER PIPE TO REMAIN. 2. EXISTING COLD WATER PIPE TO REMAIN. 2016-026A 3. SPRINKLER HEAD TO BE REMOVED. Seal EXTG VESTIBULE N.I.C. 3 3 3 TG IRS 2 I.C. EXTG MECH NAME: N.I.C. DATE: EXTG ELEV LOBBY PART 3 - EXECUTION REG NO: N.I.C. A. GENERAL 1. THE ENTIRE PLUMBING INSTALLATION, MATERIALS, EQUIPMENT, ETC. SHALL CONFORM TO THE REQUIREMENTS OF THE LOCALLY ENFORCED CODES AND STANDARDS. 1.1.COORDINATE YOUR WORK WITH THE GENERAL CONTRACTOR TO VERIFY ALL PLUMBING ROUGH IN DIMENSIONS MEET THE THESE REQUIREMENTS. 1.2.VERIFY FINAL ROUGH IN WITH ARCHITECT PRIOR TO WALL INSTALLATION. 2. TEST ALL SEWER AND WATER PIPING IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES. 3. ALL OVERHEAD PIPING IS TO BE ROUTED TIGHT TO BUILDING STRUCTURE. 4. PIPING IS NOT PERMITTED IN DEMISING WALLS. 5. DO NOT ROUTE ANY WATER CONVEYING PIPING OVER ELECTRICAL EQUIPMENT. 6. ALL EXPOSED OR ACCESSIBLE P-TRAPS MUST BE PROVIDED WITH BOTTOM CLEANOUT PLUGS. 7. INSULATE EXPOSED P-TRAPS, HOT AND COLD VALVES AND PIPING SERVING HANDICAPPED LAVATORIES. 8. PRIOR TO ANY ISOLATION OF SYSTEMS, SHUTDOWNS OR DEMOLITION THE G.C. SHALL PROVIDE NECESSARY INVESTIGATION AND NOTIFY THE FACILITIES ENGINEERING/MAINTENANCE PERSONNEL OF WORK TO BE PERFORMED SO AS TO AVOID ANY DETRIMENTAL SHUTDOWN OF SYSTEMS TO ADJACENT SPACES. 9. IF SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM. CONSTRUCTION MATERIALS ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED TYPE PER NFPA 70. 10. NO PLUMBING OR FIRE PROTECTION PIPING OR EQUIPMENT MAY BE SUPPORTED FROM THE SUSPENDED CEILING SYSTEM, BUT MUST BE INDEPENDENTLY SUPPORTED FROM THE BUILDING STRUCTURE. 11. ALL FLOOR DRAINS/CLEANOUTS ARE TO BE INSTALLED FLUSH WITH THE FINISHED FLOOR. 12. IF TRENCHING OCCURS, G.C. TO X-RAY EXISTING FLOOR TO DETERMINE LOCATIONS OF THE EXISTING UNDER FLOOR BUILDING COMPONENTS, PRIOR ANY CORE DRILLING OR PLUMBING ROUGH-IN WORK IS STARTED. 13. FURNISH ACCESS DOORS FOR WALL CLEAN OUTS AND VALVES IN WALLS. Engineer 3 C 3 3 1 3 3 3 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Job# 2016128.00 3 3 3 3 3 Seal 3 B. PIPING 1. 2. 3. PIPING SHALL BE SUPPORTED PER CODE AND LANDLORD STANDARDS. PVC PIPING SHALL NOT BE INSTALLED IN A RETURN AIR PLENUM. ALL SANITARY AND VENT PIPING SHALL PITCH TO IT'S APPROPRIATE MAIN AT NO LESS THAN 1/8" PER FOOT SLOPE. EXTG SALES AREA N.I.C. NAME: Michael B. Walsh DATE: 07/07/2016 REG NO: 123816 D. DOMESTIC WATER 1. 2. PROVIDE ANY LANDLORD REQUIRED METERS AND READERS. TEST WATER PIPING TO HYDROSTATIC PRESSURE OF 100 PSIG. FOR TWO HOURS. STERILIZE ALL DOMESTIC WATER PIPING IN ACCORDANCE WITH A.W.W.A. STANDARDS. E. INSULATION 1. INSTALLATION SHALL CONFORM TO THE MANUFACTURER'S RECOMMENDATIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. 2. CLEAN AND DRY SURFACES PRIOR TO INSULATING. 3. EXTEND INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, HANGERS AND SIMILAR PENETRATIONS. 4. INSULATION JACKET AND FITTING COVER MUST BE PLENUM RATED. 5. IT IS ESSENTIAL THAT THE INTEGRITY OF THE VAPOR-BARRIER BE MAINTAINED. SEAL ALL PENETRATIONS OF THE VAPOR BARRIER BY STAPLES, HANGERS OR WHERE OTHERWISE DAMAGED. 6. MAINTAIN ACCESS TO VALVES. Nextore project Number 73052 ISSUED FOR: F. FIRE PROTECTION 1. ALL WORK IS TO BE COMPLETED BY THE LANDLORD'S SPRINKLER CONTRACTOR AT THE GC'S EXPENSE. SPRINKLER CONTRACTOR TO INCLUDE ALL WORK, INCLUDING BUT NOT LIMITED TO, LANDLORD COORDINATION, SUBMITTALS AND CALCULATIONS, DRAIN DOWNS, ECT., AS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM REVISIONS TO SUPPORT THE NEW LENS CRAFTERS. Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction PLUMBING SPECIFICATION, SCHEDULE AND DEMOLITION PLANS Title E. METHODS 1. p 6 Creamery Brook, East Granby, CT 06026 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 REMARKS ROUND SINK FOR CONTACT LENS 1. B. MODEL # / COLOR SK-3 PART 1 - GENERAL A. MFG./PHONE # 4000 Luxottica Place, Mason, OH 45040 FR I A R MARK SUPPLIED/ INSTALLED BY a a PLAN NORTH 1 PLUMBING AND FIRE PROTECTION DEMOLITION PLAN SCALE: 1/4" = 1'-0" Date 07-01-16 Sheet Drawn By GRD Checked By MTB P100 6 1 7 SINK (SK3 & SK7) 2 8 107 N.I.C. 5 4 SINK SEP-1 4 GS-CL02-R 105 SAN. SK3 106 NEW STOCK WATER ELBOW DOWN WALL CLEANOUT TEE OUTLET UP M TEE OUTLET DOWN 4.2 2" CAP ON END LINE SK5 SANITARY PIPING (W) 3/4" COLD WATER (CW) O/H OVERHEAD VENT DN DOWN 2" 1/2" 1/2" 1-1/2" U/G UNDERGROUND - 3/4" 3/4" - EX WCO EXISTING WALL CLEANOUT WH PLUMBING FIXTURES p +1 (513) 765-6000 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Macy's Store Number: (687) VALVE HOT WATER (HW) COLD 4000 Luxottica Place, Mason, OH 45040 POINT OF NEW CONNECTION TO EXISTING PIPING OR SYSTEM SANITARY VENT PIPING (V) HOT a a WATER METER NOTE: (SK1 THRU 7) CONTRACTOR WILL BE REQUIRED TO FURNISH ALL LABOR, PIPING MATERIALS AND APPURTENANCES NECESSARY TO COMPLETE INSTALLATION OF SINKS, FAUCETS AND DRAINS FURNISHED BY OWNER. WAITING SK3 4.0 (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) ELBOW UP DRAIN SK3 SK7 ELECTRIC WATER HEATER CONTACT LENS 2.0 4.0 FIXTURE 3 10 4.0 PLUMBING FIXTURE CONNECTION SCHEDULE EXTG ELEV LOBBY CASHWRAP 9 2.0 2 SERVICE CONNECTION SIZE N.I.C. SK7 SAN F.U. SAN F.U. C.W F.U. WTR. DMD. TOTAL EACH TOTAL EACH TOTALS EXTG MECH TG IRS I.C. QTY. PLUMBING FIXTURE PLUMBING SYMBOLS WC PLUMBING CALCULATIONS Revisions: Mark STANDARD P.D.I. WH 201 WATER HAMMER ARRESTER SCHEDULE N.I.C. Date By 07/07/16 Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS 1 P.D.I. UNITS FIXTURE UNITS 1-3 4-11 12-32 33-60 61-113 114-154 155-330 R EXTG SALES AREA OPTICAL STATION N.I.C. 104 XX XX KEY NOTES - SANITARY/VENT PLAN 1. CONNECT NEW 1" PUMP DISCHARGE PIPE TO EXISTING SANITARY LINE DOWN AT THIS POINT. 2. CONNECT NEW 1 1/2" VENT TO EXISTING 2" VENT UP AT THIS POINT. 3. CONTRACTOR SHALL RUN ALL PLUMBING PIPING IN CABINET OR IN WALLS. 4. THE CEILING IN THIS AREA IS A PLENUM. USE CODE MINIMUM PIPING TO CONNECT TO THE BUILDING SERVICES. 5. PLUMBING CONTRACTOR TO PROVIDE WALL MOUNTED, 18"X18" ACCESS PANEL FOR ACCESS TO THE SEWAGE EJECTOR PUMP. ACCESS PANEL TO BE SUITABLE FOR WALL TYPE IN WHICH IT WILL BE INSTALLED, HINGED, WITH A QUARTER TURN, SCREWDRIVER CAM LATCH. COORDINATE WITH GENERAL CONTRACTOR. GENERAL CONTRACTOR TO PAINT ACCESS PANEL. 6. EXISTING 3" SANITARY DOWN TO REMAIN. 7. EXISTING 2" VENT UP TO REMAIN. 8. 1" PUMP DISCHARGE. 9. 1 1/2" VENT LINE. KEY NOTES - SUPPLY PLAN 1. CONNECT TO EXISTING DOMESTIC WATER PIPE. G.C. TO COORDINATE WORK WITH LANDLORD FOR WATER TIE IN. SEE MPE-100 2. REFER TO DETAIL C/P201 FOR WATER HEATER PIPING DETAIL. 3. CONTRACTOR SHALL RUN ALL PLUMBING PIPING IN CABINET OR IN WALLS. 2016-026A 4. APPROXIMATE LOCATION OF NEW SPRINKLER HEAD. FINAL LOCATION TO BE DETERMINED BY THE LANDLORD REQUIRED SPRINKLER CONTRACTOR. SPRINKLER CONTRACTOR'S WORK TO BE AT GC'S EXPENSE. Seal 5. NO WORK IN THIS AREA. 6. EXISTING COLD WATER PIPE TO REMAIN. 7. NEW 1/2 " COLD WATER LINE DN TO SINK. SANITARY AND VENT 8. EXISTING HOT WATER PIPE TO REMAIN. 9. NEW 3/ 4" COLD WATER PIPE. SCALE: 1/4" = 1'-0" 10. PROVIDE NEW SPRINKLER HEAD IN SOFFIT. LOCATION TO BE COORDINATED WITH SOFFIT LIGHTING AND CASEWORK BELOW. LANDLORD'S SPRINKLER CONTRACTOR SHALL DETERMINE FINAL HEAD LOCATION TO MEET ALL CODE REQUIREMENTS. PLAN NORTH 1 FR I A R Architect of Record EXTG VESTIBULE SINK AND FAUCET (SEE SCHEDULE) 10. 1 1/2" SANITARY LINE. TG IRS COLD WATER SUPPLY TO SINK C IWH-1B 2 SHUT OFF VALVE 107 EXTG ELEV LOBBY 4 N.I.C. 5 3 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Job# 2016128.00 4 CONTACT LENS 1" PIPING TO ABOVE CEILING FOR DISCHARGE WASTE SEP-1 CASHWRAP N.I.C. 7 SCALE: NONE PROVIDE UNIONS OR SIMILAR CONNECT TO ALLOW PUMP TO BE REMOVED FOR SERVICING. INSTALL UNIONS ABOVE TOP OF PUMP AND IN A LOCATION THAT IS EASY TO ACCESS. 4 REG NO: DRAIN FROM SINK WATER HEATER PIPING SCHEMATIC 1 1/2" VENT PIPING TO ABOVE CEILING SK7 6 1 9 I.C. DATE: Engineer EXTG MECH 4 WATER SUPPLY HOT WATER SUPPLY TO SINK TANKLESS WATER HEATER (SEE SCHEDULE) SK3 281 Farmington Avenue Farmington, CT. 06032 NAME: N.I.C. SK7 ASSOCIATES INC. 4 GS-CL02-R 105 2 NEW STOCK PROVIDE BALL VALVE TO STOP BACK FLOW WHEN PUMP IS REMOVED FOR SERVICE. INSTALL VALVE ADJACENT TO UNION IWH-1A SK3 4 WAITING SK3 106 3 8 4 4 N.I.C. 10 5 CHECK VALVE Seal 10 2" PIPING TO SINKS FOR DRAIN 4 4 EJECTOR PUMP WITH RESERVOIR 10 4 RETAIL 101 D SANITARY & VENT ISOMETRIC A SEWAGE EJECTOR PUMP PIPING SCHEMATIC 5 SCALE: NONE HANGER ROD SCALE: NONE EXISTING WATER LINE 3 1 3/4" NEW ISOLATION VALVE DATE: 07/07/2016 REG NO: 123816 73052 ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction PIPE 3/4" 1/2" Title FIBERGLASS INSULATION 180° RIBBED 18 GUAGE SHIELD SIMILAR TO ANVIL #168 RIB (TYPICAL) PLUMBING PLANS AND DETAILS 1 2" 1/2" 3 SK3 B 104 ASJ/SSL BUTT STRIP (TYPICAL) HEAVY DUTY CLEVIS HANGER, MATERIAL TO MATCH PIPE SK7 2 N.I.C. LOCKING NUT IWH-1B IWH-1A OPTICAL STATION Michael B. Walsh Nextore project Number SUPPORT NUT 2 EXTG SALES AREA NAME: SUPPLY ISOMETRIC SCALE: NONE E Date PIPE SUPPORT DETAIL - INSULATED PIPING SCALE: NONE PLAN NORTH 2 WATER SUPPLY AND FIRE PROTECTION SCALE: 1/4" = 1'-0" 07-01-16 Sheet Drawn By GRD Checked By MTB P200 ELECTRICAL SYMBOLS GENERAL PROVISIONS A. GENERAL CONDITIONS, CODES & STANDARDS 1. 2. 3. 4. A. GENERAL CONDITIONS OF THE CONTRACT FOUND IN THE ARCHITECTURAL DRAWINGS, GENERAL AND SPECIAL CONDITIONS OF THE AMERICAN INSTITUTE OF ARCHITECTS (AIA) (NSPE)(NEC) AND ANY OF THE TENANT'S GENERAL REQUIREMENTS SHALL APPLY UNLESS NOTED OTHERWISE. REFER TO THE GENERAL CONDITIONS ON THE ARCHITECTURAL DOCUMENTS AND THE GENERAL AND SPECIAL CONDITIONS OF THE AIA FOR ADDITIONAL REQUIREMENTS REGARDING; SAFETY, COORDINATION & COOPERATION, WORKMANSHIP, PROTECTION, CUTTING AND PATCHING, DAMAGE TO OTHER WORK, PRELIMINARY OPERATIONS, STORAGE, ADJUSTMENTS, CLEANING, ETC. ALL WORK SHALL BE IN CONFORMANCE WITH ALL LOCALLY ENFORCED, FEDERAL, STATE AND LOCAL CODES AND ORDINANCES INCLUDING ANY SPECIAL THE TENANT REQUIREMENTS IN ADDITION TO THOSE SPECIFIED. GENERAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS. B. SCOPE OF WORK THIS CONTRACT SHALL INCLUDE THE FURNISHING, INSTALLING, CONNECTING, AND OPERATION OF ALL EQUIPMENT WHICH IS A PART OF THE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS AND AS REQUIRED BY SIMILAR INSTALLATIONS. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK AND WHICH IS USUALLY INCLUDED IN WORK OF A SIMILAR CHARACTER SHALL BE FURNISHED AND INSTALLED UNDER THIS CONTRACT AT NO ADDITIONAL COST TO THE TENANT. GENERAL CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO PROVIDE THE TENANT A COMPLETE, CODE APPROVED AND OPERATIONAL ELECTRICAL SYSTEMS. 2. CAREFULLY READ SPECIFICATION FOR ALL PARTS OF THE WORK SO AS TO BECOME FAMILIAR WITH ALL TRADES' WORK SCOPE. CONSULT WITH OTHER TRADES TO INSURE PROPER LOCATIONS AND AVOID INTERFERENCES. ANY CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE TENANT BEFORE WORK IS COMMENCED. 3. ALL CONTRACTORS SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO COMPARE THEM WITH THE DRAWINGS AND SPECIFICATIONS, NOTE THE EXISTING CONDITIONS AND OTHER WORK THAT WILL BE REQUIRED, AND THE NATURE OF THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. NO ALLOWANCE SHALL BE MADE TO ANY CONTRACTOR BY REASON OF THIS FAILURE TO HAVE MADE SUCH EXAMINATION OR OF ANY ERROR ON HIS PART. 4. ALL EXISTING UTILITY AND MECHANICAL SERVICES SHALL BE FIELD VERIFIED. CORRECTIONS TO THE DESIGN AND INSTALLATION SHALL BE MADE WITHOUT ADDITIONAL COST TO THE TENANT. 5. THIS GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE THE OPENINGS WITH THE GENERAL TRADES CONTRACTOR. THE FINAL LOCATIONS AND SIZES OF ALL DUCT AND LOUVER OPENINGS SHALL BE PROVIDED BY THIS CONTRACTOR. 6. THIS CONTRACT SHALL ALSO INCLUDE ALL LABOR, MATERIALS AND MISCELLANEOUS EXPENSES REQUIRED FOR ALL REQUIRED ELECTRICAL DEMOLITION OF THE EXISTING AREAS BEING RENOVATED. 6.1. THE DEMOLITION SHALL CONSIST OF THE COMPLETE REMOVAL (PROPERLY DISPOSED OFF SITE UNLESS OTHERWISE NOTED) OF ALL ELECTRICAL EQUIPMENT, CONDUIT, MATERIALS, ETC. NOT REQUIRED IN THE FINAL DESIGN AND INSTALLATION OF THE ELECTRICAL SYSTEMS FOR THE NEW RENOVATED AREAS. 6.2. ALL UNDERGROUND SERVICES NOT BEING REUSED SHALL BE CAPPED BELOW THE FLOOR. 6.3. ALL ABOVE GROUND SERVICES SHALL BE REMOVED BACK TO THEIR RESPECTIVE MAIN AND CAPPED OR IF THE MAIN IS NOT REQUIRED, THE MAIN SHALL BE REMOVED IN IT'S ENTIRETY. 6.4. COORDINATE ALL DEMOLITION WITH THE ARCHITECTURAL DOCUMENTS AND THE ARCHITECT AND THE TENANT'S GENERAL REQUIREMENTS. 7. ALL WORK INCLUDING, BUT NOT LIMITED TO PARTS, MATERIAL, EQUIPMENT AND LABOR SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE BY THE ENGINEER AND TENANT. WHERE AN EQUIPMENT MANUFACTURER HAS A WARRANTY THAT EXCEEDS ONE YEAR, THAT WARRANTY PERIOD SHALL APPLY TO THIS PROJECT. 1. B. C. D. 2. 3. 4. 5. 6. 7. 8. 2. EXCAVATIONS SHALL BE MADE IN OPEN TRENCHES. FLOORS SHALL BE SAW CUT. PIPING SHALL BE LAID ON AN APPROPRIATELY GRADED 6" BED OF CLEAN AND DRY SAND. ENGINEERED FILL SHALL BE USED TO BACKFILL TO 6" ABOVE THE PIPING. BACKFILL THE REMAINDER OF THE TRENCH UTILIZING THE EXCAVATED MATERIAL IF APPROVED BY THE ARCHITECT OR THE TENANT. IF THE EXCAVATED MATERIALS ARE NOT ACCEPTABLE, ENGINEERED FILL ACCEPTABLE TO THE ARCHITECT SHALL BE UTILIZED TO BACKFILL THE REMAINDER OF THE TRENCH. BACKFILL SHALL BE ACCOMPLISHED IN 9" LIFTS WITH ALL LIFTS COMPACTED TO 95% PROCTOR. PATCH FLOOR TO MATCH EXISTING. EQUIPMENT, PIPING, DUCTWORK, ETC. SHALL NOT BE SUPPORTED FROM ANY CEILINGS, OTHER PIPING, CONDUIT OR DUCTWORK, ROOF DECK, OR JOIST BRIDGING. ITEMS SHALL BE SUPPORTED FROM ACCEPTABLE STRUCTURAL BUILDING COMPONENTS AS DETERMINED BY THE ARCHITECT AND STRUCTURAL ENGINEER. TESTS 1. TEST FOR GROUNDS, SHORT CIRCUITS, AND PROPER FUNCTION OF ALL EQUIPMENT AFTER INSTALLATION IS COMPLETE. FAULTS IN THE INSTALLATION SHALL BE CORRECTED AT NO COST TO THE TENANT. GUARANTEES 1. GUARANTEE FOR ONE YEAR AFTER ACCEPTANCE BY TENANT, ALL WORKMANSHIP AND MATERIALS FURNISHED. PART 2 - PRODUCTS A. B. C. D. E. F. E. METHODS 1. GROUNDING 1. GROUND ALL CONDUITS, CABINETS, MOTORS, PANELS, AND OTHER EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE ARTICLE 250. 2. GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY MEANS OF AN INSULATED GROUNDING CONDUCTOR INSTALLED WITH ALL FEEDERS AND BRANCH CIRCUIT CONDUCTORS IN ALL CONDUITS. F. D. COORDINATION GENERAL CONTRACTOR SHALL INCLUDE A VISIT TO THE JOB SITE AND TAKE INTO CONSIDERATION MECHANICAL, ELECTRICAL AND GENERAL TRADE WORK CURRENTLY EXISTING AND WORK WHICH MAY BE INSTALLED PRIOR TO CONTRACT AWARD. RELOCATION OF DUCTWORK, PIPING AND EQUIPMENT, AS REQUIRED, TO AVOID THIS WORK SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE TENANT. GENERAL CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE BUILDING SITE BEFORE STARTING ANY FABRICATION OR DOING ANY WORK IN THE FIELD AND SHALL BE RESPONSIBLE FOR THE CORRECT AND PROPER MEASUREMENTS OF HIS WORK ALONG WITH RESOLUTIONS FOR ANY CONFLICT OF SPACE WITH OTHER TRADES. WHERE THE WORK OF TWO OR MORE TRADES INTERFERE WITH EACH OTHER AND A DEVIATION FROM DESIGN IS NECESSARY, NEITHER WORK SHALL PROCEED UNTIL THE TENANT HAS BEEN NOTIFIED OF THE CONFLICT AND THEY HAVE RENDERED A DECISION AS TO WHAT CHANGES SHOULD BE MADE. GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE GENERAL CONTRACTOR CAUSING THE DAMAGE. IT IS ESSENTIAL THAT ALL WORK AT THE PROJECT BE DONE AS SUCH TIME AND IN SUCH MANNER AS NOT TO INTERFERE WITH THE NORMAL OPERATIONS OF THE FACILITY. A WORK SCHEDULE SHALL BE ARRANGED WITH THE TENANT TO FACILITATE WORK WITH A MINIMUM OF INTERFERENCE WITH THE TENANT'S OPERATIONS. AREAS TO BE USED FOR STORAGE SHALL BE ONLY AS DIRECTED BY THE TENANT. ALL STORED MATERIAL SHALL BE RELOCATED OR REMOVED FROM THE SITE AS DIRECTED BY THE TENANT. DAILY, AND AT THE COMPLETION OF THE WORK, EACH GENERAL CONTRACTOR SHALL REMOVE ALL EXCESS MATERIALS AND DEBRIS CAUSED BY HIS WORK. UPON COMPLETION OF EACH GENERAL CONTRACTOR'S WORK, CONDITIONS OF THE SPACE(S) SHALL BE THE SAME AS FOUND PRIOR TO COMMENCEMENT OF THE WORK. FAILURE TO DO SO MAY RESULT IN THE TENANT'S EMPLOYMENT OF A SEPARATE SERVICE TO OBTAIN THIS CONDITION AND REDUCING THE FACTOR'S CONTRACT AMOUNT BY THE COST OF SUCH A SERVICE. EACH GENERAL CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO OTHER WORK CAUSED BY HIS WORK OR THROUGH THE NEGLECT OF HIS, OR HIS SUB-TRADE'S PERSONNEL. ALL PATCHING, REPAIRING, REPLACEMENT AND PAINTING, ETC. SHALL BE DONE AS DIRECTED BY THE TENANT BY THE CRAFTSMEN OF THE TRADES INVOLVED. THE COSTS OF SUCH WORK SHALL BE PAID BY THE CONTRACTOR CAUSING THE DAMAGE. PERMITS AND FEES 1. THE ELECTRICAL CONTRACTOR SHALL SECURE AND PAY FOR LOCAL AND/OR STATE PERMITS AND INSPECTION FEES REQUIRED FOR THE ELECTRICAL WORK. DEMOLITION 1. DEMOLITION OF EXISTING ELECTRICAL EQUIPMENT, IF APPLICABLE, SHALL BE PART OF THE ELECTRICAL WORK AS INDICATED ON THE DRAWINGS. 1. 1. DESCRIPTION OF WORK 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL, EQUIPMENT AND TOOLS NECESSARY TO COMPLETE THE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN. 2. THE ELECTRICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH ALL PROVISIONS OF THE NATIONAL ELECTRICAL CODE (NFPA 70), AS WELL AS ANY MODIFICATIONS OR REGULATIONS PUBLISHED BY LOCAL OR STATE AUTHORITIES. THE ELECTRICAL WORK SHALL ALSO BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THE LATEST EDITIONS OF THE STATE BUILDING CODE, NFPA 71, NFPA 101 AND THE AMERICANS WITH DISABILITIES ACT WHERE APPLICABLE. 3. ELECTRICAL, MECHANICAL, ARCHITECTURAL, STRUCTURAL, AND ALL OTHER DRAWINGS, AS WELL AS SPECIFICATIONS AND ADDENDUMS SHALL BE PART OF THE CONTRACT DOCUMENTS. 4. EQUIPMENT AND MATERIALS USED ON THIS PROJECT SHALL BE NEW, U.L. LABELED AND MEET OSHA REQUIREMENTS. EQUIPMENT AND MATERIAL SHALL BE PROTECTED AND SHALL BE THE RESPONSIBILITY OF THIS GENERAL CONTRACTOR UNTIL FORMALLY ACCEPTED BY THE TENANT. 5. TEMPORARY ELECTRICAL SERVICE, LIGHTING, AND RELATED WIRING SHALL BE PROVIDED TO OSHA REQUIREMENTS FOR THE USE OF ALL TRADES DURING CONSTRUCTION. 6. PROVIDE ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF ELECTRICAL WORK. ALL CORE DRILLING OR CUTTING OF FIRE RATED FLOORS, SHAFTS AND WALLS SHALL BE FIRE STOPPED PRIOR TO FINISH PATCHING. ALL PENETRATIONS SHALL BE FIRE SEALED TO MATCH THE FIRE RATING OF THE FLOORS, SHAFTS OR WALLS PENETRATED. 7. TEMPERATURE AND INTERLOCK CONTROL COMPONENTS AND ALL RELATED CONDUIT AND WIRING SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. E. C. DOCUMENTS THE DRAWINGS ARE DIAGRAMMATIC, ALL WORK SHALL BE PERFORMED AS INDICATED ON THE DRAWINGS UNLESS EXISTING CONDITIONS OR COORDINATION ISSUES REQUIRE CHANGES. THESE CHANGES SHALL BE MADE WITH NO ADDITIONAL COST TO THE TENANT. 2. ANY INCIDENTAL ITEMS OR LABOR, ETC. NOT INCLUDED IN THE SPECIFICATIONS OR THE DRAWINGS BUT REASONABLY IMPLIED AS NECESSARY FOR THE COMPLETE INSTALLATION OF ALL APPARATUS SHALL BE INCLUDING IN BID. 3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED EVEN THOUGH NOT MENTIONED IN BOTH. 4. IF ERRORS ARE FOUND IN THE DRAWINGS OR SPECIFICATIONS OR DISCREPANCIES OCCUR BETWEEN THE SAME, OR BETWEEN THE FIGURES ON THE DRAWINGS, AND THE SCALE OF SAME OR BETWEEN THE LARGER AND SMALLER DRAWINGS, OR IN THE DESCRIPTIVE MATTER ON THE DRAWINGS SHALL BE REFERRED TO THE TENANT FOR REVIEW AND FINAL DECISION PRIOR TO THE BID DUE DATE. 5. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF EQUIPMENT AND MATERIALS EXACTLY AS SPECIFIED HEREIN. WHERE MORE THAN ONE MANUFACTURER IS MENTIONED ANY ONE MAY BE UTILIZED. SUBSTITUTE MANUFACTURERS MAY BE OFFERED ONLY AS AN ALTERNATE TO THE SPECIFIED EQUIPMENT AND MATERIAL. 5.1. SUBSTITUTIONS 5.1.1. THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE CONTRACT DOCUMENTS ARE FOR THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A BASE LEVEL OF QUALITY. THE GENERAL CONTRACTOR'S BID WILL CONTEMPLATE THE USE OF THE EQUIPMENT AND MATERIALS EXACTLY AS INDICATED. 5.1.2. THE GENERAL CONTRACTOR SHALL SUBMIT FOR APPROVAL, WITH HIS BID QUOTATION, A LIST OF ANY PROPOSED SUBSTITUTIONS OF MATERIALS AND EQUIPMENT FOR THOSE ON WHICH THE ORIGINAL DESIGN WAS BASED. A FULL DESCRIPTION OF ALL PROPOSED SUBSTITUTED ITEMS, THE CHANGE TO THEIR BID PRICE OR OTHER REASONS FOR SUCH SUBSTITUTIONS SHALL ACCOMPANY THE BID. ALL ACCESSORIES, FEATURES, ETC., SUPPLIED WITH THE SUBSTITUTED MANUFACTURER'S PRODUCT SHALL ALSO BE INCLUDED IN THE BID. 5.1.3. IF THE GENERAL CONTRACTOR DOES NOT SUBMIT PROPOSED SUBSTITUTIONS WITH THEIR BID THE TENANT SHALL CONSIDER THE BIDDER TO BE PROPOSING THE MANUFACTURERS AND MODEL NUMBERS SPECIFIED HEREIN AND SHOWN ON THE CONTRACT DRAWINGS. 5.1.4. SUBSTITUTIONS AFTER CONTRACT AWARD SHALL NOT BE PERMITTED. 6. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS. REFER TO EACH SECTION FOR ANY SPECIFIC REQUIREMENTS. 1. PART I - GENERAL G. I. THE EXISTING FIRE ALARM SYSTEM DOES NOT HAVE DETECTION OR NOTIFICATION APPLIANCES IN THE SALES AND OFFICE AREAS. THIS IS A MINOR REMODEL, AND NO SYSTEM COMPONENTS ARE ANTICIPATED. XX-## PART 3 - EXECUTION A. GENERAL MISCELLANEOUS 1. ALL CONDUIT RUN IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT SMALLER THAN 3/4" SHALL NOT BE USED FOR ANY CIRCUIT HOMERUNS. 2. RACEWAYS EXPOSED TO DIFFERENT TEMPERATURES SHALL BE FILLED WITH AN APPROVED MATERIAL IN ACCORDANCE WITH ARTICLE 300.7 OF THE NATIONAL ELECTRICAL CODE. 3. HANGERS, SUPPORTS, OR FASTENINGS SHALL BE PROVIDED AT EACH ELBOW, AT THE ENDS OF STRAIGHT RUNS TERMINATING AT BOXES OR CABINETS, AND AT INTERMEDIATE POINTS AS REQUIRED BY CODE. CONDUITS OR BOXES SHALL NOT BE SUPPORTED BY CEILING SUPPORT WIRES OR OTHER CEILING SUPPORTING HARDWARE. 4. FIXTURE SUPPORTS SHALL BE IN ACCORDANCE WITH ARTICLE 410-15 OF THE NATIONAL ELECTRICAL CODE, OR ANY LOCAL CODES WHICH MY APPLY. 5. PROVIDE PERMANENT NAMEPLATES WITH DESIGNATIONS FOR PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS. 6. PROVIDE TYPEWRITTEN DIRECTORY CARDS WITH BRANCH CIRCUIT IDENTIFICATION FOR BRANCH CIRCUIT PANELBOARDS. PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS IN ACCORDANCE WITH NEC 110.16. 7. INSTALL HANDLE GUARDS ON ALL BREAKERS FOR NIGHT LIGHTING, EMERGENCY AND SIMILAR CIRCUITS. 8. ALL FLUSH MOUNTED PANELBOARDS SHALL HAVE (3) 3/4" EMPTY CONDUITS INSTALLED TO ABOVE ACCESSIBLE CEILING FOR FUTURE USE. 9. THE FINAL LOCATIONS OF ALL EQUIPMENT, OUTLETS, ETC. SHALL BE SUBJECT TO REASONABLE CHANGES IN LOCATION UP TO THE TIME OF ROUGHING-IN, AT NO ADDITIONAL COST TO THE TENANT. 10. ELECTRICAL CONTRACTOR TO CONTACT TELEPHONE COMPANY AND MAKE NECESSARY ARRANGEMENTS FOR TELEPHONE SERVICE. 11. AT ALL TIMES KEEP PREMISES AND BUILDING IN A NEAT AND ORDERLY CONDITION, FOLLOWING TENANT'S INSTRUCTION IN REGARD TO STORING OF MATERIALS, PROTECTIVE MEASURES AND DISPOSING OF DEBRIS. XX 1. 2. 3. 4. 5. 6. PANEL WIRE AND CABLE 1. CONDUCTORS FOR POWER AND LIGHTING SHALL BE NEW 600-VOLT, 90 C, TYPE XHHW, THHN, OR THWN INSULATION, MINIMUM SIZE #12-AWG, EXCEPT FOR CONTROL WIRING WHICH MAY BE #14-AWG. OTHER SIZES SHALL BE AS NOTED ON THE DRAWINGS. CONDUCTORS SHALL BE COPPER, UNLESS OTHERWISE APPROVED BY THE TENANT. 2. BRANCH CIRCUIT RUNS EXCEEDING 100 FEET IN TOTAL LENGTH FROM THE PANELBOARD TO THE LAST DEVICE, SHALL BE #10-AWG CONDUCTORS UNLESS OTHERWISE NOTED. 3. ALL LOW VOLTAGE COMMUNICATIONS, FIRE ALARM, DATA, SECURITY, TELEPHONE AND ALL OTHER MISCELLANEOUS LOW VOLTAGE WIRING INSTALLED IN CEILING SHALL BE PLENUM RATED. 4. TELEPHONE WIRING SHALL BE 4 PAIR 22/24 AWG (PLENUM RATED). MANUFACTURER SELECTED BY EC. 5. DATA (EYENET-POS) WIRING SHALL BE BERK-TEK LANMARK-1000, CATEGORY 6. RATED CMP, WHERE USED IN PLENUM CEILINGS AND RATED OSP WHERE USED BELOW SLAB. PROVIDE 6' OF EXCESS CABLE AT CASHWRAP AND 6' OF CABLE AT THE PHONEBOARD AND OTHER LOCATIONS. TENANT VENDOR TO PERFORM PUNCHDOWN AND SYSTEMS VERIFICATION. 6. BASE PROJECT FOR LOW VOLTAGE WIRING (VOICE AND DATA) IS INSTALLATION OF RACEWAY ONLY FOR THE ELECTRICAL CONTRACT. PRICING FOR INSTALLATION AND TERMINATION OF WIRING AT OUTLETS IN LENSCRAFTERS ONLY IS DESIRED. THE PUNCHDOWN AND CROSS CONNECTS IN THE MACY'S CLOSETS ARE BY TENANT OR MACY'S IN BOTH BASE BID AND ALTERNATE BID CASES. WIRING DEVICES 1. DUPLEX RECEPTACLES SHALL BE GROUNDING TYPE, NEMA 5-20R, RATED FOR 20 AMPS, 125 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. 1.1. SPECIFICATION GRADE DUPLEX RECEPTACLE SHALL BE HUBBELL #5362 SERIES OR APPROVED EQUAL, HEAVY DUTY, WHITE. 1.2. ISOLATED GROUND DEDICATED DUPLEX RECEPTACLE SHALL BE HUBBELL #IG-5362 SERIES OR APPROVED EQUAL, ORANGE. 1.3. GROUND FAULT CIRCUIT INTERRUPTER (GFI) DUPLEX RECEPTACLES SHALL BE PROVIDED WHERE INDICATED. 2. SWITCHES SHALL BE TOGGLE OPERATED, QUIET TYPE, RATED FOR 20 AMPS, 120/277 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. THREE WAY AND FOUR WAY SWITCHES SHALL BE PROVIDED WHERE INDICATED. 2.1. SINGLE POLE SWITCHES SHALL BE LEVITON #1221 SERIES OR APPROVED EQUAL, SILENT ACTUATING, 20-AMP, 120/277V, WHITE. 2.2. THREE POLE SWITCHES SHALL BE LEVITON #1223 SERIES OR APPROVED EQUAL, SILENT ACTUATING, 20-AMP, 120/277V, WHITE. 3. DIMMERS SHALL BE LEVITON SLIDING DIMMER SWITCH, OF A RATING, VOLTAGE AND WATTAGE SUITABLE FOR LOAD SERVED.COLORS OF DEVICES AND COVERPLATES SHALL WHITE. 4. WIRING DEVICES SHALL BE SPECIFICATION GRADE, AS MANUFACTURED BY HUBBELL, PASS & SEYMOUR, ARROW HART, LEVITON AND GENERAL ELECTRIC, UON. 5. COVERPLATES FOR POWER, DATA & TELEPHONE SHALL BE LEVITON OR APPROVED EQUAL, WHITE, PLASTIC. 6. LIGHTING CONTRACTORS SHALL BE IN NEMA 1 ENCLOSURE, NORMALLY OPEN ELECTRICALLY HELD, 120V, COIL, 20A. REFER TO PLANS FOR NUMBER OF POLES. ILLUMINATED "EXIT" SIGN LIGHTING FIXTURE. CEILING MOUNTED OR WALL MOUNTED. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON FLOOR PLANS. CIRCUIT COMBINATION VOICE/DATA OUTLET - MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. "W" INDICATES WALL MOUNTED AT 54" AFF, "C" INDICATES MOUNTED 8" ABOVE COUNTER. 4000 Luxottica Place, Mason, OH 45040 p +1 (513) 765-6000 a 6 Creamery Brook, East Granby, CT 06026 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Macy's Store Number: (687) TELEPHONE OUTLET - MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. "W" INDICATES WALL MOUNTED AT 54" AFF, "C" INDICATES MOUNTED 8" ABOVE COUNTER, "P" INDICATES PUBLIC TELEPHONE OUTLET - COORDINATE MOUNTING HEIGHT. DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN FLOOR BOX. "CLG" INDICATES MOUNTED IN CEILING DATA OUTLET: MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. "W" INDICATES WALL MOUNTED AT 54" AFF, "C" INDICATES MOUNTED 8" ABOVE COUNTER. CLG INDICATES CEILING MOUNTED. COMBINATION DUPLEX RECEPTACLE AND VOICE/DATA OUTLET MOUNTED IN FLOOR BOX. DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN FLOOR BOX. 2 2 PORT DATA OUTLET Revisions: Mark BRANCH CIRCUIT WIRING HOMERUN MOTOR Architect of Record LIGHT FIXTURE: "AD" INDICATES FIXTURE TYPE "a" INDICATES SWITCH CONTROL. REFER TO LUMINAIRE SCHEDULE FOR DESCRIPTION. TL CLIENT COMMENTS 6 PORT DATA OUTLET 6 CEILING MOUNTED OCCUPANT SENSOR TRACK AND TRACK MOUNTED LIGHT FIXTURE (DESIGNATIONS VARY SEE PLANS) #T-S 07/19/16 SWITCHED WIRING "3" INDICATES THREE WAY SWITCH "4" INDICATES FOUR WAY SWITCH "C" INDICATES SWITCH MOUNTED 8" ABOVE COUNTER "OS" INDICATES OCCUPANCY SENSOR SWITCH "D" INDICATES DIMMER SWITCH - WATTAGE AS INDICATED ON PANEL SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR AD By Description SUBMIT FOR PERMIT 4 PORT DATA OUTLET 4 3 3 PORT DATA OUTLET SWITCH - SINGLE POLE TOGGLE TYPE - 120/277 VOLT, 1-HP RATED, 20 AMPERE, MOUNTED AT 48" AFF UNLESS OTHERWISE NOTED: OS Date 07/07/16 1 COMMUNICATIONS FLOOR BOX SPEAKER TO REMAIN. DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE. RETURN THE BALANCE TO MACY'S OPERATIONS. RECONNECT CIRCUIT AS REQUIRED TO KEEP REMAINING LIGHT FIXTURES POWERED. EXISTING STRIP LIGHTS BEHIND VALANCE ARE TO REMAIN. EXISTING LIGHT FIXTURES ARE TO REMAIN. EXISTING RECESSED, ADJUSTABLE ACCENT LIGHTS ARE TO REMAIN. EXISTING 2X4 TO BE RELOCATED. SEE LIGHTING PLAN FOR NEW LOCATION. EXTEND CONDUIT AND CONDUCTOR AS REQUIRED TO HAVE A COMPLETE AND OPERATIONAL SYSTEM. a LIGHTING TIME CLOCK TC DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED: "2" INDICATES CIRCUIT NUMBER "E" EXISTING TO REMAIN "WP" INDICATES WEATHERPROOF COVER "D" DEDICATED CIRCUIT "GFI" INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE "R" INDICATES RECESSED F FIRE ALARM MANUAL PULL STATION MOUNTED AT 48" AFF. F FIRE ALARM AUDIO/VISUAL ALARM SIGNAL WALL MOUNTED AT 80" AFF. V FIRE ALARM VISUAL ONLY ALARM SIGNAL WALL MOUNTED AT 80" AFF. SD FIRE ALARM SMOKE DETECTOR SD FIRE ALARM SMOKE DETECTOR - DUCT MOUNTED ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 2016-026A Seal 1 EXTG VESTIBULE N.I.C. (D) TG IRS DATE: N.I.C. 2 I.C. NAME: EXTG MECH 6 EXTG ELEV LOBBY (R) REG NO: N.I.C. 1 Engineer C 2 2 (D) (E) (D) 1 (E) 4 4 (E) (R) (E) 2 (E) 3 3 3 (E) 3 (E) 3 (E) 3 (E) 3 (E) (E) 3 EXTG SALES AREA 5 (E) 5 (E) 5 5 4 (E) 4 (E) (E) (E) S 4 4 (E) (E) (E) (E) NAME: Michael B. Walsh DATE: 07/07/2016 REG NO: 123816 4 Nextore project Number 4 (E) (E) (E) Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title 1 S (E) PLAN NORTH 1 73052 ISSUED FOR: 4 (E) 4 (E) (E) (E) 4 4 4 (E) 4 Seal (E) 1 (E) 4 4 (E) (E) (E) (E) (E) (E) (E) (E) 5 (E) (E) (E) EX/D1 4 (E) (E) (E) (E) 4 4 (E) (E) 4 5 5 4 5 5 5 4 4 5 N.I.C. 5 (E) 5 (E) (E) 5 5 3 5 (E) (E) (R) (E) 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Job# 2016128.00 (E) (E) (E) 3 (E) (E) (E) 3 (D) 6 (E) 3 (R) 3 3 (R) (E) (E) FIXTURES AND LAMPS 1. ALL FIXTURES AND LAMPS ARE FURNISHED BY TENANT, INSTALLED BY ELECTRICAL CONTRACTOR.. FIRE ALARM SYSTEM D JUNCTION BOX J KEY NOTES - ELECTRICAL DEMOLITION PLAN LIGHTING AND RECEPTACLE PANELBOARDS 1. BRANCH CIRCUIT PANELBOARDS SHALL BE DEAD FRONT TYPE, WITH MAIN LUGS OR MAIN OVERCURRENT DEVICE AS INDICATED, BRANCH OVERCURRENT DEVICES AS NOTED AND AN EQUIPMENT GROUND BAR, ALL IN A FLUSH MOUNTED SHEET STEEL ENCLOSURE. MINIMUM SHORT CIRCUIT CAPACITY SHALL BE 10,000 AMPS SYMMETRICAL FOR 120/208V, AND 14,000 AMPS SYMMETRICAL FOR 277/480V APPLICATION UNLESS NOTED OTHERWISE. 2. ALL BREAKERS FEEDING HVAC EQUIPMENT SHALL BE HACR RATED, UNLESS OTHERWISE NOTED. 3. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE D, GENERAL ELECTRIC, ITE/SIEMENS AND WESTINGHOUSE/CUTLER HAMMER. SAFETY SWITCHES AND MOTOR STARTERS 1. SAFETY SWITCHES SHALL BE FUSIBLE OR NON-FUSIBLE AS INDICATED ON THE DRAWINGS. SWITCHES SHALL BE QUICK-MAKE, QUICK-BREAK, HEAVY DUTY VISIBLE BLADE TYPE. ENCLOSURES SHALL BE NEMA 1 TYPE UNLESS OTHERWISE INDICATED ON THE DRAWINGS. FUSED SHALL BE DUAL ELEMENT TIME DELAY TYPE. 2. MAGNETIC MOTOR STARTERS SHALL BE COMBINATION TYPE WITH THERMAL OVERLOAD, INTEGRAL FUSED SAFETY SWITCH, H-O-A SELECTOR SWITCH, CONTROL TRANSFORMER, RUNNING PILOT LIGHT, NEMA TYPE 1 ENCLOSURE, AND (2) NORMALLY OPEN AND (2) NORMALLY CLOSED AUXILIARY CONTACTS. 3. ALL MOTORS OVER 1/8 HP SHALL BE PROVIDED WITH THERMAL OVERLOAD PROTECTION. OVERLOAD PROTECTION SHALL BE PROVIDED INTEGRAL WITH THE MOTOR WINDINGS AND/OR MOTOR CONTROLLER (PROVIDED BY OTHERS) UNLESS OTHERWISE INDICATED ON DRAWINGS. RECESSED DOWNLIGHT. DESIGNATIONS VARY - SEE PLANS. INFLOOR/UNDERFLOOR CONDUIT/WIRE CONDUIT 1. CONDUIT SHALL BE HEAVY WALL RIGID GALVANIZED STEEL WHERE EXPOSED AND SUBJECT TO DAMAGE, 8'-0" AFF AND BELOW, AND IN WET LOCATIONS WHERE INDICATED ON THE DRAWINGS. UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC AND SHALL BE CONCRETE ENCASED (3' MINIMUM) WHERE INDICATED ON THE DRAWINGS. A TRANSITION SHALL BE MADE TO HEAVY WALL RIGID GALVANIZED STEEL BEFORE PVC CONDUITS PENETRATE THE FLOOR SLAB. INTERIOR CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT). METAL CLAD (MC) CABLE MAY BE USED IF APPROVED BY THE TENANT, AND INSTALLED IN LOCATIONS PERMITTED BY CODE. 2. FLEXIBLE METAL CONDUIT SHALL BE USED FROM OUTLET BOX TO INDIVIDUAL RECESSED LIGHT FIXTURES, AND FOR FINAL CONNECTIONS TO MOTORS AND OTHER DEVICES SUBJECT TO VIBRATION CONDUIT FITTINGS AND BOXES 1. INTERIOR OUTLET BOXES SHALL BE STANDARD GALVANIZED SHEET STEEL TYPE, NOT LESS THAN 14 GAUGE IN THICKNESS, WITH KNOCKOUT OPENINGS, EXTENSIONS, PLASTER RINGS AND COVER PLATES TO ACCOMMODATE THE DEVICES INSTALLED. COVER PLATES SHALL BE SMOOTH PLASTIC TO MATCH DEVICE COLOR. USE STEEL PLATES WITH ROUNDED CORNERS FOR SURFACE BOXES. OUTDOOR (WET LOCATION) OUTLET BOXES SHALL BE CAST ALUMINUM TYPE WITH DEVICE COVERS TO SUIT. 2. OUTLET BOXES SHALL NOT BE LESS THAN 4 INCHES SQUARE, 1-1/2 INCHES DEEP. 3. COUPLINGS AND CONNECTORS FOR EMT SHALL BE DIE CAST ZINC OR STEEL. BUSHING SHALL BE GROUNDING TYPE WITH INSULATING PLASTIC INSERT. 4. FLOOR JUNCTION BOX WITH COVER SHALL BE HUBBELL #S1PFB DEEP BOX WITH #S1TFCAL ALUMINUM FINISH COVER (FOR TILE APPLICATION) OR #S1CFCAL ALUMINUM FINISH COVER (FOR CARPET APPLICATION), SUBPLATE S1SP. PROVIDE DEVICES AS INDICATED ON THE DRAWINGS. 5. POKE THROUGH TO BE HUBBELL S1PTFIT WITH #S1TFCAL ALUMINUM FINISH COVER (FOR TILE APPLICATION) OR #S1CFCAL ALUMINUM FINISH COVER (FOR CARPET APPLICATION), SUBPLATE S1SP. PROVIDE DEVICES AS INDICATED ON THE DRAWINGS. 6. ALL COVER PLATE FOR WALL SWITCHES AND RECEPTACLES SHALL BE WHITE. HOMERUN TO PANEL AND CIRCUIT INDICATED FR I A R I. (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) Date ELECTRICAL SPECIFICATIONS, SYMBOLS AND DEMOLITION PLAN 07-01-16 ELECTRICAL DEMOLITION PLAN Drawn By SCALE: 1/4" = 1'-0" Checked By GRD MTB Sheet E100 C. REFER TO THE MECHANICAL PLANS FOR EXACT LOCATION OF MECHANICAL EQUIPMENT AND REQUIRED ELECTRICAL CONNECTIONS. IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS, THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING "AS BUILT" DRAWINGS FROM THE SUBCONTRACTORS AND SUBMITTING SAME TO NEXTORE PROJECT MANAGER. F. IT IS THE E.C.'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM (WITH-IN 10%). SEE ARCHITECTURAL ELEVATIONS FOR ADDITIONAL INFORMATION ON PLACEMENT OF OUTLETS & SWITCHES. H. ANY PENETRATIONS THROUGH FIRE-RESISTANT/RATED WALLS, PARTITIONS, FLOORS, AND CEILINGS SHALL BE FIRESTOPPED USING APPROVED METHODS TO MAINTAIN THE FIRE RESISTANCE RATING. I. RECEPTACLE CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS ABOVE 250'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. DUCTWORK AND PIPING SHALL NOT BE ROUTED OVER ELECTRIC PANELS OR TRANSFORMERS. K. IT IS THE RESPONSIBILITY OF THE E.C. TO REVIEW ALL ARCHITECTURAL DRAWINGS, ELECTRICAL DRAWINGS AND NOTES TO INSURE THAT ALL ELECTRICAL REQUIREMENTS ARE MET. L. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES AND ORDINANCES. M. ALL OUTLETS IN THE LENS PROCESSING ROOM ARE TO BE LABELED WITH PANEL AND CIRCUIT NUMBER. N. THE E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. O. ALL TELEPHONE CABLING/DATA CABLING TO BE RUN IN CONDUIT TO 6" ABOVE CEILING. PROVIDE 6' OF EXTRA CABLING AT ALL TELEPHONE/DATA HEAD END LOCATIONS. P. ALL CABLING SHALL BE PLENUM RATED. RUN PHONE/DATA CABLING COMPLETELY IN CONDUIT IF LOCAL CODES/MUNICIPALITIES REQUIRE IT (FIELD VERIFY). ALL CABLING SHALL BE ROUTED AWAY FROM ALL ELECTRIC EQUIPMENT (WITH-IN 18") AND SECURED TO STRUCTURE ABOVE. 4 3 2 OR AND AND SYSTEMONE SUB-PLATE HUBBELL S1SP4X4 SYSTEMONE SUB-PLATE HUBBELL S1SP S1CFCAL (CARPET) / S1TFCAL (TILE) S1CFCAL (CARPET) / S1TFCAL (TILE) B ALL CABLING TO BE PLENUM RATED. ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 FLOOR BOX AND POKE THRU DETAIL 2016-026A SCALE: NONE Seal DATA INTERCONNECTION RISER SCALE: NONE 1 8 ALL DATA/PHONE CABLING MUST BE SEPARATELY COLOR CODED AND PROPERLY IDENTIFIED W/ NUMBER AND/OR COLOR SYSTEM AT BOTH ENDS. SYSTEMONE FLOOR BOX HUBBELL S1PFB SYSTEMONE FLOOR BOX HUBBELL S1PFB NOTE: ONLY DATA CONDUIT IS SHOWN ON THIS RISER. SEE PLAN FOR POWER CONDUITS. A-13 EXTG VESTIBULE N.I.C. LCI-GH30 LCI-GH16 GS-FN02B GS-FN09 A-13 6 (TYP) 1 A-20 EQ112 SE-OD01-L A-6 3 A-6 EQ6A EQ1 GFI A-6 SE-OD02 SE-OD03 OPTOS 1 EQ100A GS-FN08B SE-TOWEL-C BOH-UP24 GS-CL02-R EQ102 NAME: 9 EXTG MECH J DATE: N.I.C. A-15 EXTG ELEV LOBBY CASHWRAP 107 Engineer J BOH-UP24 GS-PW95 A-19 1 1 SK3 A-19, 21, 23 WAITING GS-FN02B 106 GS-PW94 LCI-GH30 GS-FN04 BOH-UP24 EQ6 EQ22A A-7 RECESSED ELECTRIC PANEL GS-PW10 GS-PW01A_L GS-PW01A_R A 01 -PW 11 GS W -P 31 _C GS 1A P W W0 GSP GS _L A 01 W P S G G 1 W0 S-P OPTICAL STATION N.I.C. 104 THE EXISTING SYSTEM DOES NOT HAVE DETECTION OR A/V DEVICES IN THE SALES FLOOR. THEREFORE, NO NEW DEVICES ARE BEING ADDED INTO THIS MINOR REMODEL. CONTRACTOR SHALL COORDINATE WORK AND COST REQUIRED WITH LANDLORDS FIRE ALARM VENDOR FOR ADDED DEVICE IN OFFICE SPACE. A-3 1 GS_L 01A W P S PW0 1 PW1 R 1A_ PW0 GS- 01A_L GS-PW 01A_CW01A_R GS-PW A_C W31 GS-P 1 0 W GS-P GS-P A-8 7 Seal 11 15 20W CW 4 5 RETAIL 2 3 101 A-5 A-18 A-19 07 -FN GS 1 A-21, 23 7 -LF GS 0W 07 -FN GS GS- A-5 A-18 2 16 GS 2 LF5 GS-LF50 GS- LF21 GS-LF50 2 3 A-16 1 GS-LF11 GS-LF52 GS-LF53 ELECTRICAL POWER PLAN SCALE: 1/4" = 1'-0" 07/07/2016 REG NO: 123816 Nextore project Number 73052 ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title ELECTRICAL POWER AND LOW VOLTAGE PLAN AND DETAILS PLAN NORTH 1 DATE: 1 2 16 GS-LF13 Michael B. Walsh LF10 07 -FN GS NAME: GS-LF53 GS-LF50 1 2 16 3 1 A-5 A-18 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Job# 2016128.00 1 R 1A_ GS- 2 07 -FN GS R G A_ PW1 _C 7 EXTG SALES AREA 1 _L 01A _75 S-PW 1 G 6 PW A-18 GSGS- 10 -PW GS GS- 5 J A-17 (TYP) 6 14 10 A-5 7 10 GS-PW W91 EQ8C PROVIDE POWER, TELEPHONE AND DATA CONDUIT WITHIN FLOOR, BETWEEN FIXTURE AND NEAREST WALL AS INDICATED ON PLANS. METHOD OF CORE DRILLING SHALL BE PER BUILDING REQUIREMENTS. ALL CORE DRILL REQUIREMENTS SHALL BE VERIFIED WITH LANDLORD. CONTRACTOR SHALL SIZE CONDUIT PER NEC. PROVIDE FOR X-RAY OF FLOOR WHERE REQUIRED BY THE LANDLORD. BOH-UP24 BOH-UP24 EQ21 GS-FN08B NEW PANEL "A" A-16,18 11 GS-PW A-9 7 GS-P GS-FN04 1 CORE DRILLING AND TRENCHING NOTE F A-22 2 B. REG NO: N.I.C. GS-FN08B 105 N.I.C. 00C J GFI BREAKER A-24 NEW STOCK EQ101 EQ105C 13 DATA PRICING NOTES A. CLIENT COMMENTS S1PTFIT POKE THRU OR (1) CAT6 (BY OTHERS) FROM FLOOR BOX AT FIXTURE TO FLOOR BOX AT CASH DESK IN 3/4" CONDUIT. N.I.C. GENERAL NOTES - FIRE ALARM 07/19/16 Architect of Record (2) CAT6 (BY OTHERS) FROM FLOOR BOX AT FIXTURE TO FLOOR BOX AT CASH DESK IN 3/4" CONDUIT. G.C. SHALL PURCHASE AT LUXOTTICA NATIONAL ACCOUNT AGREED PRICING ALL DISCONNECT ELECTRIC DISTRIBUTION PANELS, AND FLOOR BOXES. CONTACT LUXOTTICA NATIONAL ACCOUNT REPRESENTATIVE FOR PRICING INFORMATION AND INCLUDE IN BID E.C. SHALL INCREASE CONDUIT SIZE BY ONE TRADE SIZE, IF CONDUIT BENDS EXCEED 180 DEGREES. ELECTRICAL CONTRACTOR, FOR BASE PRICING, IS RESPONSIBLE FOR THE HOMERUNS TO THE MACY'S EQUIPMENT ROOMS AND IN THE LENSCRAFTERS AREA, THE RACEWAY SYSTEM ONLY. Description SUBMIT FOR PERMIT BOX CALL OUT: STANDARD S1PT4X4FIT POKE THRU (3) CAT6 (BY OTHERS) FROM FLOOR BOX AT FIXTURE TO FLOOR BOX AT CASH DESK IN 1" CONDUIT. NOTE: SEE POWER PLAN FOR ADDITIONAL RECEPTACLES AND POWER CONNECTIONS. A BOX CALL OUT: 4X4 FITTING (1) CAT6 (BY OTHERS) FROM FLOOR BOX AT FIXTURE TO FLOOR BOX AT CASH DESK IN 3/4" CONDUIT. CONTACT A-4 LENS 1. 2. By 1 EXTG STAIRS SEE DATA RISER ON THIS SHEET FOR ADDITIONAL INFORMATION. Date 07/07/16 1 THREE STANDARD FLOOR BOXES AT CASH DESK. TWO FOR DATA, ONE FOR POWER (ONE DOUBLE DUPLEX) IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS, THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING "AS BUILT" DRAWINGS FROM THE SUBCONTRACTORS AND SUBMITTING SAME TO NEXTORE PROJECT MANAGER. V. Mark LCI-GH30 CONDUIT AND OUTLETS FOR SECURITY, DATA, TELEPHONE, AND ELECTRIC MAY REQUIRE REMOVAL OF CONCRETE SLAB OR ROUTING OF CONDUIT UNDER FLOOR IN SPACE BELOW. ANY PENETRATIONS THROUGH FIRE-RESISTANT/RATED WALLS, PARTITIONS, FLOORS, AND CEILINGS SHALL BE FIRESTOPPED USING APPROVED METHODS TO MAINTAIN THE FIRE RESISTANCE RATING. Revisions: INSTALL IN (ONE) 1" C AND (ONE) 1 1/2" C, FROM WALL TO FLOOR BOX/POKE THRU 1 J. U. Macy's Store Number: (687) INSTALL IN (ONE) 1" C AND (ONE) 1 1/2" C, FROM WALL TO FLOOR BOX/POKE THRU 1 (1) CAT6 (BY OTHERS) FROM WALL BOX AT BACKWRAP TO FLOOR BOX AT CASH DESK IN 1" CONDUIT. 1 G. T. 1 1 E. S. +1 (516) 393-2484 INSTALL IN 1" C 1 ALL TEMPORARY WIRING SHALL BE REMOVED WHEN PERMANENT POWER IS AVAILABLE. R. 1 (2) CAT6 (BY OTHERS) FROM WORK COUNTER TO FLOOR BOX AT CASH DESK INSTALL IN 1" C +1 (513) 765-6000 p 1 D. Q. 2 p 6 Creamery Brook, East Granby, CT 06026 FR I A R FLEXIBLE CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO MILLWORK, INTERIOR LIGHTING FIXTURES, AND EQUIPMENT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE 12'-0". CONTRACTOR TO RUN (1) CAT6 TO MACY'S TELEPHONE ROOM AND (1) CAT6 TO MACY'S P.O.S. / DATA CLOSET FOR MACY'S USE. LEAVE 12FT COILED IN ROOM. 1 (4) CAT6 (BY OTHERS) FROM FLOOR BOX AT FIXTURE TO FLOOR BOX AT CASH DESK IN 1" CONDUIT. ALL MOUNTING HEIGHTS FROM THE CENTERLINE OF THE BOX TO THE FINISHED FLOOR ARE AS FOLLOWS, UNLESS NOTED OTHERWISE ON PLAN: SWITCHES-48", ELECTRICAL/TELEPHONE/DATA OUTLETS-18", TOP OF PANELBOARDS-6'-6", TIMECLOCKS-5'-0". FOR ALL LENS PROCESSING ROOM OUTLET MOUNTING HEIGHTS SEE EQUIPMENT WIRING SCHEDULE. B. AT CASH DESK IN EXAM AREA 5 GENERAL NOTES A. DOCTOR'S SWITCH 4000 Luxottica Place, Mason, OH 45040 a GS-LF92 15. 16. AT WORK COUNTER, (2) DATA INSTALLED AT 18" AFF AND (2) DOUBLE DUPLEX OUTLETS AT 18" GS-LF52 10. 11. 12. 13. 14. OPTOS 1 GS-CW20 8. 9. 3 a A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 LCM-GR32 4. 5. 6. 7. 1 CONTRACTOR TO RUN (2) CAT6 TO MACY'S TELEPHONE ROOM AND (1) CAT6 TO MACY'S P.O.S. / DATA CLOSET FOR LENSCRAFTER'S USE. LEAVE 12FT COILED IN ROOM. SE-GH-CHART 3. INSTALL AT 18" AFF IN DOCTOR'S OFFICE. EQ109B 2. PROVIDE DIRECT CONNECTION IN WALL TO SERVE TANKLESS WATER HEATER. CONNECTION TO BE 25A, 120V, SINGLE PHASE. CIRCUIT AS INDICATED. COORDINATE LOCATION WITH PLUMBING CONTRACTOR. PROVIDE TRENCHING FOR POWER AND TELE/DATA TO SELECT TABLE. E.C. SHALL VERIFY ALL TRENCHING REQUIREMENTS WITH THE LANDLORD PRIOR TO THE START OF WORK. PROVIDE DEVICES AND DEVICE QUANTITIES AS SPECIFIED ON PLANS. E.C. SHALL COORDINATE INSTALLATION AND CONNECTION REQUIREMENTS WITH FURNITURE MANUFACTURER REPRESENTATIVE. PROVIDE "STANDARD" FLOOR BOX/POKE THRU AT THIS LOCATION - SEE DETAIL B/E200 AND THE DATA INTERCONNECTION RISER. PROVIDE JUNCTION BOX AND CIRCUIT FOR EYE EXAM SIGN. PROVIDE JUNCTION BOX ABOVE CEILING FOR LENSCRAFTERS SIGN. VERIFY MOUNTING HEIGHTS OF OUTLETS WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN. CONNECT CIRCUIT TO MACY'S LIGHTING CONTROL SYSTEM. SEE DETAIL A/E201. VERIFY SPECIFIC REQUIREMENTS WITH MACY'S. 1 INSTALL RECESSED RECEPTACLE AS SHOWN ON ARCHITECTURAL ELEVATION FOR THE DIGITAL EYE CHART. ROUTE ONE 3/4" CONDUIT TO ABOVE CEILING FROM EMPTY 4X4 JUNCTION BOX WITH MUDRING INSTALLED AT HEIGHT EQUIVALENT TO ADJACENT POWER OUTLET. BUSH CONDUIT END AND PROVIDE PULL STRING. ROUTE CONDUIT 6" ABOVE CEILING AND BUSH END. TYPICAL. SEE DATA INTERCONNECTION RISER FOR DATA CONDUIT SIZES. PROVIDE PULL STRING. TYPICAL. NOT USED. COORDINATE LOCATION OF RECEPTACLE INSTALLATION WITH ACCESS PANEL AND PUMP. 1 RECEPTACLE AND JUNCTION BOX SERVES DIGITAL SIGNAGE. SEE ELEVATION ON ARCHITECTURAL SHEETS. VERIFY EXACT LOCATION OF ROUGH IN WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN. ROUTE 1" CONDUIT FOR POWER. PROVIDE "4X4 FITTING" FLOOR BOX/POKE THRU AT THIS LOCATION. SEE DETAIL B/E200 AND THE DATA INTERCONNECTION RISER. EQ108 1. (2) CAT6 TO MACY'S PHONE BOARD. (1) CAT6 (BY OTHERS) 1 BETWEEN JACKS KEY NOTES - ELECTRICAL PLAN EQ119 XX NOTE: INSTALL CONDUITS IN SAME TRENCH (WHEN TRENCHING). FEED DATA WIRING THROUGH DATA JUNCTION BOXES AND SHARE CONDUITS WITH OTHER DATA WIRE - DO NOT SPLICE AND DO NOT ROUTE DATA/COMM IN THE SAME RACEWAY AS POWER. SEE SHEET E400 FOR ADDITIONAL INFORMATION ON CASEWORK. Date 07-01-16 Sheet Drawn By GRD Checked By MTB E200 TYPE AD PART-NUMBER MANUFACTURER METALUX INPUT WATTS 34.5 22ALNG-LD4-35-UNV-L835-CD1-U LAMP QTY N/A LAMP TYPE INTEGRAL LED, 3482 LUMENS DESCRIPTION MOUNTING RECESSED 2X2 LED TROFFER A. CEILING TYPE RECESSED ACT AD AD- EM 22ALNG-LD4-35-UNV-L835-CD1-U -EL14W METALUX AD-EM X2 2T-S TL 4T-S TL 6T-S TL 8T-S TL 12T-S TL 34.5 N/A INTEGRAL LED, 3482 LUMENS 14W EMERGENCY - 1400 LUMENS RECESSED 2X2 LED TROFFER WITH EMERGENCY BATTERY BACKUP. RECESSED LIGHT ALARMS SPLEDWRCD 3 N/A LED INCLUDED RECESSED EXTRUDED ALUMINUM EDGE LIT EXIT SIGN WITH RED LETTERS FOR CEILING OR WALL MOUNTING RED LED INCLUDED. TO BE RECESSED MOUNTED U.N.O. (FOR NYC OR CHICAGO CONFIRM WITH MANUF). PROVIDE CURRENT LIMITER WHERE REQUIRED. 2T-S JUNO T2WH - - TRACK ONLY - SEE TRACK HEAD 2 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL JUNO T690WH 18 1 GE LED18D38W3930/25; 18W; 92 CRI; 3000K; PAR38, MED BASE GIMBAL STYLE LAMP-HOLDER, WHITE 4T-S JUNO T4WH - - TRACK ONLY - SEE TRACK HEAD 4 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL JUNO T690WH 18 1 GE LED18D38W3930/25; 18W; 92 CRI; 3000K; PAR38, MED BASE GIMBAL STYLE LAMP-HOLDER, WHITE 6T-S JUNO T6WH - - TRACK ONLY - SEE TRACK HEAD 6 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL JUNO T690WH 18 1 GE LED18D38W3930/25; 18W; 92 CRI; 3000K; PAR38, MED BASE GIMBAL STYLE LAMP-HOLDER, WHITE 8T-S JUNO T8WH - - TRACK ONLY - SEE TRACK HEAD 8 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL JUNO T690WH 18 1 GE LED18D38W3930/25; 18W; 92 CRI; 3000K; PAR38, MED BASE GIMBAL STYLE LAMP-HOLDER, WHITE 12T-S JUNO T12WH - - TRACK ONLY - SEE TRACK HEAD 12 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL JUNO T690WH 18 1 GE LED18D38W3930/25; 18W; 92 CRI; 3000K; PAR38, MED BASE GIMBAL STYLE LAMP-HOLDER, WHITE X2 ACT TRACK SEE FOOTNOTE 1 TRACK C. IT SHALL BE THE E.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE E.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. D. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON-SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION. E. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, E.C. SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION. F. E.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD. G. LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. SEE FOOTNOTE 1 I. SEE FOOTNOTE 1 SEE FOOTNOTE 1 TRACK J. FOOTNOTES: 1. SEE PLANS FOR TRACK LOCATIONS. PROVIDE CURRENT LIMITERS AND PENDANTS WHERE CALLED FOR ON THE PLANS. XX CONNECT TO NEAREST MACY'S 120V MERCHANDISE LIGHTING CIRCUIT SWITCHED WITH MACY'S LIGHTING CONTROL SYSTEM. 120V COIL LOAD DESCRIPTION CASEWORK AND SIGNS WALL SHELF LIGHTING 1. ALL NIGHT (NL) LUMINAIRES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING H. TRACK EMERGENCY (EM) LUMINAIRES SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT" TO PROVIDE CONTINUOUS POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF. B. SEE FOOTNOTE 1 TRACK ENERGY CODE - COMMISSIONING COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE OFFICE AREA: 1.1. 1.2. 1.3. 2. OCCUPANCY SENSORS DETECT MOTION AND ENERGIZE THE LOCAL SWITCHING. LOCAL SWITCHING IS DIMMABLE, ALLOWING A RANGE OF DIMMING FROM 5% TO 100%. OCCUPANCY SENSORS DE-ENERGIZE AFTER NO MOTION IS DETECTED AFTER A 30 MINUTE DELAY. 2.2. 2.3. SIGNS, PERIMETER SHELVING AND SALES FLOOR DISPLAY CABINETS ARE ENERGIZED AND DE-ENERGIZED WITH THE MACY'S DISPLAY LIGHTING CONTROL. SUPPLEMENTAL TRACK LIGHTING IS LIMITED TO 125% OF THE CONNECTED WATTAGE OF TRACK HEADS. SUPPLEMENTAL TRACK LIGHTING IS CONTROLLED WITH THE MACY'S ACCENT LIGHTING CONTROL. E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. M. FOR ALL REMODELS, RETROFIT ALL EXISTING FLUORESCENT LIGHTS WITH T12 FIXTURES TO T8, INCLUDING BALLASTS AND LAMPS XX 1. CIRCUIT A-5, 9 PROVIDE OCCUPANCY SENSOR TO CONTROL LIGHTS IN AREA. CONNECT LOAD SIDE OF SENSOR POWER PACK TO LINE SIDE OF AREA SWITCHING. AREA SWITCHING DOES NOT RECEIVE POWER UNLESS THE SENSOR POWER PACK DETECTS MOTION. SET SENSOR TO 30 MINUTE TIME OUT AND MAXIMUM SENSITIVITY. SEE B/E201. CLIENT COMMENTS 2. EMERGENCY FIXTURES SHALL HAVE EMERGENCY BATTERY BACK UP OR EMERGENCY BALLAST AND BE SERVED BY UNSWITCHED LEG OF LOCAL CIRCUIT TO PROVIDE CONTINUOUS ILLUMINATION PER LIFE SAFETY CODE.. 3. LIGHTING IN THIS AREA IS FROM MACY'S STORE. 4. SPEAKERS ARE EXISTING TO REMAIN. 5. RELOCATED 2X4 FIXTURE. 6. MATCH EXISTING RECESSED, ADJUSTABLE ACCENT LIGHT. TIE TO EXISTING NEARBY LIGHTING BRANCH CIRCUIT FOR POWER/CONTROL. VERIFY LOAD DOES NOT EXCEED 1.92KVA ON A 1P-20A, 120V CIRCUIT. 1 ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 Seal 3/D EXTG VESTIBULE N.I.C. (N) AD I.C. (N) (N) AD-EM 3/D TG IRS OS (N) (N) AD EXTG MECH OS (N) AD 1 NAME: N.I.C. 1 DATE: EXTG ELEV LOBBY CASHWRAP SE-OD02 OPTION 1: CONNECT CONTACTOR COIL TO ADJACENT LIGHTING CIRCUIT CONTROLLED BY MACY'S LIGHTING CONTROL SYSTEM. WALL SHELF LIGHTING 07/19/16 2016-026A 2 107 X2 (N) REG NO: N.I.C. 3/D (R) BOH-UP24 CONTACT LENS BOH-UP24 GS-CL02-R SK3 WAITING 105 A-5, 9 N.I.C. A-3 CONTACTOR TO BE SQUARE D OR EQUAL, 20A CONTACTS, ELECTRICALLY HELD IN NEMA1 ENCLOSURE. INSTALL ABOVE CEILING WHERE PERMITTED BY CODE. X2 (N) 2 106 NEW STOCK CIRCUIT A-1 2 (N) AD AD-EM (N) 5 Engineer 1 OS (N) AD CONNECT TO MACY'S 24V LIGHTING CONTROL SYSTEM. ROUTE PLENUM RATED WIRING WHERE REQUIRED. WIRING IS NOT REQUIRED IN CONDUIT UNLESS THE JURISDICTION REQUIRES IT. 24V COIL Description SUBMIT FOR PERMIT Architect of Record A-3 GENERALLY, THE LIGHTING CONTROL SYSTEM IS PRESENT IN ANY MACY'S ELECTRIC ROOMS. VERIFY IN FIELD. VERIFY EXACT REQUIREMENTS WITH MACY'S OPERATIONS. MICHIGAN AND TOLEDO MACY'S STORES USE ANDOVER CONTROLS (GENERALLY) AND INET (RARELY). By KEY NOTES 1 CASEWORK AND SIGNS Date 07/07/16 1 CONTACTOR TO BE SQUARE D OR EQUAL, 20A CONTACTS, ELECTRICALLY HELD IN NEMA1 ENCLOSURE. INSTALL ABOVE CEILING WHERE PERMITTED BY CODE. LOAD DESCRIPTION +1 (516) 393-2484 Mark EMERGENCY AND EXIT LUMINAIRES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST NATIONAL ELECTRICAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL-VOLTAGE WITH BATTERY BACKUP (120/277 VOLT INPUT). INSTALL A CENTRAL BATTERY SYSTEM WHERE THE USE OF INDIVIDUAL BATTERY UNITS ARE PROHIBITED BY LOCAL CODES. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION. L. +1 (513) 765-6000 p Revisions: E.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY NEXTORE. E.C. IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, E.C. SHALL CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH LUXOTTICA. E.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. p 6 Creamery Brook, East Granby, CT 06026 Macy's Store Number: (687) LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE THRU-WIRING WHEREVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. LIGHTING FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE THRU-WIRING, ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. K. 4000 Luxottica Place, Mason, OH 45040 a A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE SALES AREA: 2.1. a (N) OS 1 (N) AD 3/D SYMBOL GENERAL NOTES FR I A R LIGHTING SCHEDULE (N) AD-EM 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Job# 2016128.00 2 D 5 (E) (R) (E) (E) (E) (E) (E) RETAIL 101 GENERALLY, THE LIGHTING CONTROL SYSTEM IS PRESENT IN ANY MACY'S ELECTRIC ROOMS. VERIFY IN FIELD. VERIFY EXACT REQUIREMENTS WITH MACY'S OPERATIONS. MICHIGAN AND TOLEDO MACY'S STORES USE ANDOVER CONTROLS (GENERALLY) AND INET (RARELY). (E) EXTG SALES AREA OPTICAL STATION N.I.C. 104 (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (N) (E) (E) S (E) 6 (E) 4 (E) (E) Seal (E) (E) (E) (E) (E) (E) (E) (E) (E) (N) AD (E) (E) (E) 6 (E) (E) 1 (E) (E) (N) (E) (E) OPTION 2: CONNECT CONTACTOR COIL TO MACY'S LIGHTING CONTROL SYSTEM. EX/D1 NAME: Michael B. Walsh DATE: 07/07/2016 REG NO: 123816 (E) 3 A MACY'S LIGHTING CONTROL INTERFACE ISSUED FOR: (E) LIGHT (E) (E) (E) S B LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction ELECTRICAL LIGHTING PLAN AND DETAILS (E) SENSOR POWER PACK UNSWITCHED CIRCUIT Date OCCUPANCY SENSOR CONTROL SCALE: NONE Client Review Title 4 AREA LIGHT SWITCH SENSOR 73052 (E) (E) SCALE: NONE OS Nextore project Number PLAN NORTH 1 LIGHTING PLAN SCALE: 1/4" = 1'-0" 07-01-16 Sheet Drawn By GRD Checked By MTB E201 ONE-LINE DIAGRAM NOTES FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT GENERAL CONTRACTORS COST. BIDDING GENERAL CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. ELECTRICAL LOAD SUMMARY PANEL "A" LIGHTING SHOW WINDOW RECEPTACLE CONNECTED LOAD (KW) DEMAND FACTOR 2.15 1.25 2.7 0.000 1.0 0.000 .5 SIGN DEMAND LOAD (KW) 1.25 100% 10K 50%>10K 1.0 EQUIPMENT 5.2 WATER HEATER 4.8 HVAC ---- ----- 15.15 15.7 42 43 TOTAL (AMPS) 3. PROVIDE NAMEPLATES PER NAMEPLATE DETAIL. 4. COORDINATE SPACE WITH ALL OTHER TRADES TO MAINTAIN ALL CODE- REQUIRED CLEARANCES. 5. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 6. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH NEC ARTICLE 110.16 FOR LABELING OF PANELS FOR ARC FLASH HAZARD WARNING AS WELL AS FOLLOWING REQUIRED SAFETY PRECAUTIONS WHEN SERVICING OR MAINTAINING ELECTRICAL EQUIPMENT. 1. MACY'S ELECTRIC ROOM LENSCRAFTERS +1 (513) 765-6000 p +1 (516) 393-2484 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 EXISTING MACY'S ELECTRICAL PANEL IN MACY'S ELECTRICAL ROOM (SEE MPE-100). FURNISH AND INSTALL NEW 60 AMP 3 POLE BREAKER FOR FEED TO LENSCRAFTERS. Macy's Store Number: (687) (4)#6, (1)#8 GND IN 1 1/4" C. WHERE PERMITTED BY THE JURISDICTION AND LANDLORD, MC CABLE CAN BE USED FOR THIS INSTALLATION. ENGRAVED LAMACOID, 5/32" LETTERS, SECURE TO PANEL BOARD COVER WITH ADHESIVE TYPE FASTENER. A EXISTING PANEL 120/208 225A NEW PANEL "A" 120/208V 3Ø 60A MCB Revisions: Mark 07/19/16 CLIENT COMMENTS 5.2 4.8 Architect of Record VOLTAGE DROP CALCULATION VD = 2 x L x R x I 1000 ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 MACY'S PANEL TO PANEL IN SPACE: DISTANCE TO SPACE: WIRE SIZE TO SPACE: AMPS: VD = 2 x 74 x 0.4 x 45 1000 74 FT. 4#6 (R=0.4) 45 By Description SUBMIT FOR PERMIT 1 FLOOR VOLTAGE DROP TO BE LESS THAN 3% Date 07/07/16 2.5 2.5 TOTAL (KW) THE ELECTRICAL CONTRACTOR SHALL VERIFY THE AVAILABLE FAULT CURRENT WITH THE LANDLORD PRIOR TO BIDDING AND PROVIDE EQUIPMENT RATED ACCORDINGLY. SUBMIT FAULT CURRENT CALCULATIONS WITH SHOP DRAWING SUBMITTAL. : p 6 Creamery Brook, East Granby, CT 06026 .5 RECEPTACLES 1.25 2. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL LANDLORD REQUIREMENTS PRIOR TO BIDDING & INCLUDE THE COST OF ALL ASSOCIATED LABOR, MATERIALS, & CHARGES IN HIS BID. 4000 Luxottica Place, Mason, OH 45040 a FR I A R LOAD DESCRIPTION 1. ELECTRIC ONE LINE DIAGRAM a 2016-026A Seal 1 = 2.7 V 2.7 V x 100 = 0.74 % 208 3 V 1 1 NAME: DATE: REG NO: Engineer 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Job# 2016128.00 Seal NAME: Michael B. Walsh DATE: 07/07/2016 REG NO: 123816 Nextore project Number 73052 ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction Title ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULE Date 07-01-16 Sheet Drawn By GRD Checked By MTB E300 CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER) LF-50 (1) 92" LED STRIP 21W X TOTAL 21W LF-51 (4) 76" LED STRIP 68W (3) 60W DRIVERS (1) 48" LED STRIP 11W TOTAL 79W LF-52 (6) 76" LED STRIP 102W (4) 60W DRIVERS (1) 72" LED STRIP 19W TOTAL 121W TOTAL 21W INFORMATION IS PER 4FT SECTION. TOTAL XW EQ109B REFRACTION STAND 120 EQ108 ORIENT OUTLETS AS SHOWN. POWER FOR THE END CABINETS "LF-50" IS SUPPLIED FROM MAIN CABINET "LF-52". THE LED STRIP LIGHTS ARE PRE-INSTALLED BY THE CASEWORK SUPPLIER WITH A WHIP LEFT FOR LOW VOLTAGE CONNECTION TO A 60W DRIVER IN "LF-52". ELECTRICAL CONTRACTOR SCOPE IS TO CONNECT THE LED LIGHTING TO THE DRIVER PRE-INSTALLED CASEWORK "LF52". ELECTRICAL OUTLET INSTALLED BY EC AT 15" AFF. TO LEDs IN CASEWORK. WIRING, DRIVER AND LEDs ARE INSTALLED BY CASEWORK SUPPLIER. LF52: (1) 100W DRIVER AND (2) 60W DRIVERS PRE-INSTALLED. 1" 1'-12 2'-0" 60W DRIVER GS-PW01_R 1'-181" LF50: (1) 60W DRIVER PRE-INSTALLED IN "LF-52". EC TO PLUG DRIVER INTO RECEPTACLE CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER) LF-71 (1) DATA 0W REQUIRES (1) DATA FEED AND TWO 20A (1) DOUBLE DUPLEX 360W (1) DUPLEX 1300W CIRCUITS BY EC TOTAL 1660W LF52 540W GS-LF71 1'-2" TOTAL 120 2.1 X X EQ103 LENSOMETER 120 1 X EQUIPMENT IS NOT IN USE IN THIS PLAN. 1 GFI EQ119 EQ100A OPTOS 42" 3 EQ6A Mark Date EQ108 Description SUBMIT FOR PERMIT 07/19/16 CLIENT COMMENTS 1 EQUIPMENT ELECTRICAL/MECHANICAL REQUIREMENTS NOTES ID DESCRIPTION VOLT AMP BTU NEMA #5 - 20R EQ6 LENSOMETER (MANUAL) 120 1 X Architect of Record EQ101 TONOMETER 120 1 X THIS EQUIPMENT PLUGS INTO EQ100C EQ22 FRAME WARMER 120 13 X NEMA #5 - 20R, DEDICATED OUTLET EQ102 REFRACTOMETER 120 1 X THIS EQUIPMENT PLUGS INTO EQ100C EQ21 EYE NET STATION 120 2 X NEMA #5 - 20R DC EQ105C OCULUS 120 1.1 X THIS EQUIPMENT PLUGS INTO EQ100C EQ8C FRAME TRACER 120 2.1 X NEMA #5 - 20R DC EQ104 120 0.5 X THIS EQUIPMENT PLUGS INTO EQ100C EQUIPMENT IS NOT IN USE IN THIS PLAN. X EMPLOYEE TIME CLOCK 120 1.1 X NEMA #5 - 20R 120 2 X NEMA #5 - 20R; EQUIPMENT IS NOT IN USE IN THIS PLAN. EQ24 ULTRASONIC CLEANER 120 1 X NEMA #5 - 20R; EQUIPMENT IS NOT IN USE IN THIS PLAN. EQ43 SPECTROMETER 1 X NEMA #5 - 20R; EQUIPMENT IS NOT IN USE IN THIS PLAN. VISION TESTER 05C EQ1 EQ 120 EQ By 07/07/16 EQ109B EQ11B DIAMOND EDGER LEAVING THE CASH DESK: PROVIDE CONDUITS AS SHOWN ON THE DATA INTERCONNECTION RISER, SHEET E200. ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 2016-026A Seal D GS-FN07 EQ21 GS-LF70 EQ +1 (516) 393-2484 Revisions: EQ SUPPLY FOR THE CASH DESK: PROVIDE CONDUITS AS SHOWN ON THE DATA INTERCONNECTION RISER, SHEET E200. EQ KERATOMETER EQUIPMENT ELECTRICAL/MECHANICAL REQUIREMENTS ID DESCRIPTION VOLT AMP BTU NOTES EQ100C TRIPLE POWER TABLE 120 1 X THIS TABLE PLUGS INTO THE WALL CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER) LF-70 (1) DATA 0W REQUIRES (1) DATA (1) DOUBLE DUPLEX 360W FEED AND TWO 20A (1) DUPLEX 180W CIRCUITS BY EC EQ GS-FN07 EQ119 EC TO PROVIDE A SINGLE FLOOR BOX (WITH DIVIDER) CENTERED IN AREA SHOWN. FLOOR BOX TO HAVE DUPLEX RECEPTACLE AND DATA OUTLET. PROVIDE CONDUITS AS SHOWN ON THE DATA INTERCONNECTION RISER, SHEET E200. ROUTE CORD UP CABINET LEG. CORD IS SUPPLIED BY CASEWORK SUPPLIER AND INSTALLED BY THE EC. CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER) CW-20 (3) DATA 0W REQUIRES (3) DATA (2) DOUBLE DUPLEX 720W FEED AND TWO 20A (1) DUPLEX 180W CIRCUITS BY EC TOTAL 900W THREE FLOOR BOXES BY EC. ONE FOR POWER, TWO FOR LOW VOLTAGE. SEE POWER PLAN AND DATA INTERCONNECTION RISER FOR ADDITIONAL INFORMATION. X LF13 LF50 GS-PW10 GS-PW01_C LF50 GS-PW11 GS-PW01_C +1 (513) 765-6000 p INSTALL OUTLET 8" BELOW CEILING FLOOR BOX BY EC 60W DRIVER p 6 Creamery Brook, East Granby, CT 06026 Macy's Store Number: (687) LF50: (1) 60W DRIVER PRE-INSTALLED IN "LF-52". 60W DRIVER 60W DRIVER 4000 Luxottica Place, Mason, OH 45040 a A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 3 1'-2" 100W DRIVER a N/A EQ118C ELECTRICAL OUTLET INSTALLED BY EC AT 18" AFF. REQUIRES DATA 120 ACCESS HOLE IN FURNITURE CROSS MEMBER BETWEEN FURNITURE LEGS DOUBLE DUPLEX RECEPTACLE PRE-INSTALLED IN CABINET BY CASEWORK SUPPLIER. WIRING FROM RECEPTACLE TO LED DRIVER AND ASSOCIATED LED STRIP LIGHTS IS PRE-INSTALLED. ELECTRICAL CONTRACTOR SCOPE IS TO PROVIDE A FLOOR BOX AND PLUG IN THE CASEWORK TO THE FLOOR BOX. X EQ100A OPTOS EQ101 TO LEDs IN CASEWORK. WIRING, DRIVER AND LEDs ARE INSTALLED BY CASEWORK SUPPLIER. OUTLET DOORS PATIENT CARE 2.1 FR I A R (1) 60W DRIVER EQUIPMENT ELECTRICAL/MECHANICAL REQUIREMENTS ID DESCRIPTION VOLT AMP BTU NOTES EQ6A LENSOMETER (AUTO) 120 1 X NEMA #5 - 20R EQ100C TOTAL 42W PW-11 (1) 92" LED STRIP 21W CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER) LF-13 (1) X" LED STRIP XW (1) 100W DRIVER EQ1 02 CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER) PW-10 (2) 92" LED STRIP 42W (1) 60W DRIVER EQ22A EQ8C EQ6 GS-CW20 GS-FN07 EC TO PROVIDE TWO FLOOR BOXES CENTERED IN AREA SHOWN. FLOOR BOXES TO HAVE DUPLEX RECEPTACLE AND DATA OUTLET. PROVIDE CONDUITS AS SHOWN ON THE DATA INTERCONNECTION RISER, SHEET E200. EQ EQ THREE FLOOR BOXES BY EC. ONE FOR POWER, TWO FOR LOW VOLTAGE. GS-FN07 NAME: DATE: REG NO: Engineer CASEWORK ELECTRICAL LF-71 (1) DATA (1) DOUBLE DUPLEX (1) DUPLEX TOTAL 2'-0" CASEWORK ELECTRICAL CW-20 (3) DATA (2) DOUBLE DUPLEX (1) DUPLEX TOTAL REQUIRES (1) DATA FEED AND TWO 20A CIRCUITS BY EC EQ EQ EQ LEAVING THE CASH DESK: PROVIDE CONDUITS AS SHOWN ON THE DATA INTERCONNECTION RISER, SHEET E200. TOTAL EQ GS-CW20 GS-FN07 GS-FN07 LENSCRAFTERS THREE FLOOR BOXES BY EC. ONE FOR POWER, TWO FOR LOW VOLTAGE. 1 1 6 8 9 9 1 6 8 1 100W LED DRIVER INSTALLED BY CASEWORK MANUFACTURER RECEPTACLE IN WALL BEHIND UNIT INSTALLED AT 54" AFF TO CENTERLINE. Michael B. Walsh DATE: 07/07/2016 REG NO: 123816 Nextore project Number 73052 ISSUED FOR: Client Review LL Approval DOB Permit Bid DOB Permit - Re-Submit Construction 6 8 6 8 9 CASEWORK DETAILS 1 1 6 8 2 2 3 3 Title 5 7 2 4 BACKLIT LENSCRAFTERS SIGN (30W ESTIMATED LED LOAD) NAME: 9 5 7 3 20W LED POWER CONNECTOR INSTALLED BY CASEWORK MANUFACTURER EC TO PROVIDE TWO FLOOR BOXES CENTERED IN AREA SHOWN. FLOOR BOXES TO HAVE DUPLEX RECEPTACLE AND DATA OUTLET. PROVIDE CONDUITS AS SHOWN ON THE DATA INTERCONNECTION RISER, SHEET E200. EQ 6 8 5 8 CASEWORK ELECTRICAL (INSTALLED CASEWORK SUPPLIER) LF-90 (2) 20" LED STRIP 20W (1) 100W DRIVER GS-LF70 EQ 1 EQ SUPPLY FOR THE CASH DESK: PROVIDE CONDUITS AS SHOWN ON THE DATA INTERCONNECTION RISER, SHEET E200. GS-FN07 GS-FN07 ALL POWER WIRING IS TO BE IN METAL RACEWAY. SECURE RACEWAY TO INSIDE OF FURNITURE. COORDINATE WORK WITH THE GC. 811 Middle Street Middletown, CT 06457 Tel. (860) 632−1682 Fax. (860) 632−1768 Job# 2016128.00 0W REQUIRES (1) DATA 360W FEED AND TWO 20A 180W CIRCUITS BY EC 540W 1'-2" EQ THREE FLOOR BOXES BY EC. ONE FOR POWER, TWO FOR LOW VOLTAGE. SEE POWER PLAN AND DATA INTERCONNECTION RISER FOR ADDITIONAL INFORMATION. ELECTRICAL CONTRACTOR IS TO PROVIDE AND INSTALL ALL ELECTRICAL EQUIPMENT SHOWN IN THE DETAILS. NO WORK IS PROVIDED BY THE CASEWORK MANUFACTURER. THE DATA CABLING IS THE ONLY WIRING NOT IN THE ELECTRICAL CONTRACTOR'S SCOPE. CASEWORK ELECTRICAL LF-70 (1) DATA (1) DOUBLE DUPLEX (1) DUPLEX TOTAL 0W REQUIRES (3) DATA 720W FEED AND TWO 20A 180W CIRCUITS BY EC 900W Seal GS-LF71 ELECTRICAL LEGEND DESCRIPTION # 1 MC CABLE, 12/2 w/GROUND, 12 AWG 2 MC CABLE, 12/3 w/GROUND, 12 AWG 3 4X4 JUNCTION BOX 4 CORD & PLUG. ONE PER CIRCUIT. 20A RATING, CONTINUOUS DUTY. 5 DUPLEX 20A RECEPTACLE 6 DOUBLE DUPLEX, 20A RECEPTACLE 7 FED BY CIRCUIT #1 8 FED BY CIRCUIT #2 9 SINGLE GANG BOX WITHOUT A COVER FOR DATA (DATA WIRING BY OTHERS). 0W 360W 1300W 1660W 4 3 4 4 3 3 4 4 Date 07-01-16 Sheet Drawn By GRD Checked By MTB E400