Bulk water meter ZF-series
Transcription
Bulk water meter ZF-series
Bulk water meter ZF-series ZENNER GmbH & Co. KGaA, Römerstadt 4, 66121 Saarbrücken, Germany Tel.: 00 49 681-99 67 60 Fax: 00 49 681-643 94 E-mail: [email protected] http: //www.zenner.de Bulk Water Meter ZF-series WPH-ZF Sizes DN 40 - DN 500 WPH-K-ZF-I-N DN 50 A modular approach was used in the development of the W-ZF meter series. This can be seen by the broad range of applications in which the meter can be used. In its simplest form, the meter can be used as a purely mechanical meter that utilizes a Woltman style measuring technique. However, this basic meter also has a removable insert which can be easily serviced. Furthermore the meter can be readily upgraded to generate a range of different pulse outputs which in turn can link the meter to a complex communications network. WPH-K-ZF-N DN 200 Body and insert 2 Special features are: EEC approval class B from DN 50 to DN 200 Turbine bearing: The standard version turbine bearing consists of hard metal and corundum which wear to a minimum and thus guarantee high durability. Pinion bearing: The pinion connecting turbine and counter runs on bearings with sapphire (corundum) on both ends. The W-ZF development is based on a ”total solutions” concept. Meter sizes DN 80 to DN 150 employ a well proven measuring insert that delivers the high accuracy and lifetime usually associated with Woltman technology. However, the sizes DN 40/65 and DN 200 represent a further development in terms of accuracy. The meter is designed for water temperatures of up to 50° C and as a hot water meter or volume measuring unit for energy meters of up to 130°C . The insert is removable and thus well accessible for maintenance. The body is completely coated with plastic powder providing tough, durable protection against corrosion and impacts. Standard bodies are rated to PN 16 (1600kPa). ISO 7005-2 flange dimension conform to ISO 7005-2 PN 10; ISO 7005-2 flange dimension conform to ISO 7005-2 PN 16 is also on our list. On request a high pressure version PN 25 for all meter sizes is available. The insert ensures long term, high level of accuracy and is within class B measurement accuracy. The WPH-ZF is constructed according to the standards of ISO 4064 class B and meets the relevant EEC standards for cold water. All screws and nuts in the insert are made from stainless steel. Magnet protection: The meter is protected against interference from external magnetic fields. For horizontal and vertical installation. WPH-ZF The multifunctional counter with six big number rollers and two pointers is easily read and presents itself in a modern, appealing design. The counter can be equipped with plastic or mineral glass. The anti-condensation coating (nano-coating) guarantees optimal readability of the counter. The counter can also be adjusted to the desired position and thus makes simple and correct reading of the display possible. The encapsulated, evacuated counter sealed with an O-ring is protected against flooding and can be equipped with an additional dry cartridge on request. Steel sealing cap: protects the window against dirt and damage. A plastic sealing cap which can be rotated by 360° is also available on request. The plastic sealing cap can be adjusted according to the mounting position and mounting conditions of the meter. ”The sky is the limit” in regard to the pulse output options: Reed*, Opto and Namur type pulsers can be fit directly in WPH counters up to DN 500. A key feature of this meter is that these pulsers can be installed without disturbing the calibration seal. A field installer can fit the pulser without the need to reseal the meter. The pulser can also be secured with an additional lead seal. This range of products can be tied into the CHEKKER® system with the CHEKKER® pulse counter module visio. Counter The counter is a completely new development and meets all requirements for a modern counter of today. An electronic counter is currently under development. This module will fit directly into the meter replacing the mechanical gear box and rollers. It will provide unprecedented levels of accuracy and extensive communication and data logging facilities. A host of technical solutions that handle the output pulses from the meter and process them are available. * Double-reed version in development. Head loss curve Error curve WPH-K-ZF Approvals DN 40 l A p p ro v a n h a s b e e r. fo a p p li e d DN 50 B99 325.13 DN 65 B00 325.16 DN 80 B99 325.09 D N 1100 00 B99 325.10 D N 1125 25 B00 325.15 D N 1155 0 B99 325.12 DN 200 B00 325.14 3 Bulk Water Meter ZF-series WPH-ZF Technical data Nominal diameter DN mm 40 50 65 80 100 125 Nominal flow rate Qn m³/h 15 15 25 40 60 100 Qmax m³/h 60 90 120 150 250 300 Maximum flow rate (short-term) m³/h 30 45 60 90 125 170 Qt m³/h 0,9 0,9 1,2 6 6 8 Qmin m³/h 0,35 0,35 0,45 0,8 1,5 3 Flow rate at 0.1 bar head loss m³/h 20 30 50 70 100 150 Pressure loss at Qmax bar 0,2 0,1 0,1 0,2 0,2 0,2 Maximum water temperature °C 50 Maximum working pressure bar 16 Maximum flow rate (durable) Transitional flow rate Minimum flow rate Maximum dial indication m Minimum dial indication l 3 9.999.999 0,2 Metrological class B Nominal diameter DN mm 150 200 250 300 400 500 Nominal flow rate Qn m³/h 150 250 400 600 1000 1500 Qmax m³/h 350 650 1200 1500 2500 4000 m³/h 250 325 600 700 1250 2000 Qt m³/h 12 12 20 50 100 200 Qmin m³/h 3,5 6,5 12 18 30 45 Flow rate at 0.1 bar head loss m³/h 200 650 1000 1500 2500 4000 Pressure loss at Qmax bar 0,2 0,05 0,05 0,05 0,05 0,05 Maximum water temperature °C 50 Maximum working pressure bar 16 Maximum flow rate (short-term) Maximum flow rate (durable) Transitional flow rate Minimum flow rate Maximum dial indication m Minimum dial indication l 3 Metrological class horizontal Pipeline vertical diagonal Head of meter 4 999.999.999 20 200 B * Approval has been applied for. Installation 99.999.999 upwards aside WPH-ZF Display for DN 40 and DN 125 Displays reed 2 position 1000 l/p Namur opto sensor position reed 1 position 100 l/p Display for DN 150 to DN 300 reed 2 position 10 m3/p Nominal diameter DN Lowest scale value 40 / 125 mm 0,2 l 150 / 300 mm 20 l 400 / 500 mm 200 l Namur opto sensor position reed 1 position 1000 l/p Display for DN 400 and DN 500 reed 2 position 100 m3/p Namur opto sensor position reed 1 position 10 m3/p Nominal diameter DN mm 40 50 65 80 100 125 Nominal flow Qn m³/h 15 15 25 40 60 100 Length L mm 200 200 200 225 250 250 Height H mm 206 200 208 255 275 290 Flange Ø D mm 150 165 185 200 220 250 kg 9,8 10,6 11,6 15,4 17,8 21,6 Weight Nominal diameter DN mm 150 200 250 300 400 500 Nominal flow Qn m³/h 150 250 400 600 1000 1500 Length L mm 300 350 450 500 600 800 Height H mm 305 375 470 495 635 740 Flange Ø D mm 285 340 395 445 565 670 kg 31,5 46 94 114 199 340 Weight Dimensions 5 Bulk Water Meter ZF-series System CHEKKER® ZF-V series Electronic Woltman Meter visio Meter electronics for 12 years Check number for 100% correct consumption values Programmable downtime-detection Programmable leak-detection S.R.D. (Specified Reading Date) can be reprogrammed on-site Compact- and split-models for ideal meter reading WPH-K-ZF-V-N DN 50 System CHEKKER® 100% tested values for billing by reading with check number ® The system CHEKKER consists of the following components: meter technology with check number for all media checking software and improves the quality of your reading data. ZF-V series All pulse-applicable Woltman meters from the ZF series can be quickly and easily upgraded with the CHEKKER® pulse counter module visio to electronic billing meters of the System CHEKKER® with check number. The electronic module visio works with the newest generation of microprocessor-controlled pulse counter with a running time of 1122 years years. The internal memory saves all important data at regular intervals. In the reading mode the consumption value as well as the check number is displayed by simply pushing a button. CHEKKER® pulse counter module visio Compact version Total consumption value After pushing the button: Segment test Automatic switch after 4 seconds: Check number and billing value Automatic reset of the display after 30 seconds 6 The reading value can be checked for accuracy by the check number. Digits which are mixed up and incorrectly collected reading values are recognized for sure. Only 100% tested reading values are used for billing. For further detailed information on the CHEKKER® System and the CHEKKER® Meter Technology please System CHEKKER®“. request our brochure „System The following data can be accessed in the servicemode: S.R.D. (Specified Reading Date) monthly values calibration validity manipulation error status In addition, the devices can be programmed in the factory to recognize special operating situations: Downtime-detection: meter failures are identified by the programmable downtime detector and are encoded in the check number. Leak-detection: with the programmable leak detector leaks in the plumbing are identified and encoded in the check number. The visio module is available as compact- and splitversion. The compact device is clipped directly onto the counter; the split version is fastened with a cable and for an ideal reading, should be installed with a wall mounting device. WS-ZF Robust for extreme applications Very low pressure loss in spite of the integrated filter Also available as a volumetric measuring unit for energy meters WS-K-ZF-I-N DN 100 Easy maintenance due to removable measuring insert. Regulation in measuring insert (not in body). Anti-condensation coating for optimal readability of counter. Suitable for fluctuating flow rates due to wide measuring range; typical uses are e.g. in schools, holiday complexes and industrial plants Low start-up and high sensitivity. Integrated stainless steel filter. Long-life bearings due to special wearresistance materials. Dry dial six-roller counter with big roller numbers. Pinion bearing: The pinion connecting turbine and counter runs on bearings with sapphire (corundum) on both ends. Magnet protection against interference from external magnetic fields. Low pressure loss. Metrological properties according to ISO 4064 class B, but better than class B. Maximum corrosion protection by epoxy powder coating. Prepared for Reed switch*, Opto and Namur devices. Optional equipment with electronic pulse counter module. WS for cold water up to 30°C (safe up to 50°C), for warm water up to 90°C (safe up to 120°C), for hot water up to 130°C and as volume measuring unit for energy meters. Operating pressure up to PN 16. High pressure version up to PN 25. For horizontal installation. Available as CHEKKER® version or subsequent upgrade possible with the CHEKKER® pulse counter module visio. EEC approval for ISO and DIN length class B for cold water. Other national approvals. * Double-Reed version in development. Error curve 7 Bulk Water Meter ZF-series WS-ZF Head loss curve Display reed 2 position 1000 l/p Namur opto sensor position reed 1 position 100 l/p Technical data Nominal diameter DN mm 50 65 80 100 150 Nominal flow rate Qn m³/h 15 25 40 60 150 Maximum flow rate (short-term) Qmax m³/h 30 70 110 180 350 Maximum flow rate (durable) m³/h 20 40 55 90 200 Qt m³/h 1 3 3 5 10 Qmin m³/h 0,15 0,2 0,2 0,3 0,8 Transitional flow rate Minimum flow rate Maximum working pressure bar Flow rate at 0.1 bar head loss m³/h 20 35 40 70 150 Pressure loss at Qmax bar 0,2 0,2 0,2 0,3 0,6 Maximum dial indication Minimum dial indication 16 m 3 99.999.999,99 m 3 0,2 Metrological class Dimensions 8 Nominal diameter Better than ISO 4064 class B DN mm 50 65 80 100 Length L mm 270/300 300 Height H mm 228 238 290 306 435 Outer dia D mm 165 185 200 220 285 Bolt circle D1 mm 125 145 160 180 240 8(4) Ø18 8 Ø18 8 Ø22 29 31 78 Connecting bolt number Hole diameter pc. mm Weight kg 4 Ø18 14 23 300/350/370 350/360/370 150 500 Filter * The filter consists of a cast body, a lid plate fixed with screws and a removable strainer made of stainless steel. No soiling of the pipe network by foreign matter. Additional protection of the water meter‘s mechanism by premounting. Simple maintenance by easy cleaning of the strainer after removal of the lid plate. Attention should be paid to the flow direction of the water during the installation. Operating pressure 16 bar. Applicable for cold water up to 50 °C (PN 10/ 16-4 or PN 10/16-5)* and hot water bis 130° C (PN 10/16-4 or PN 10/16-5)*. Version with bar magnet to filter magnetites away from water also available. Also available for high pressure version on request. PN 10/16-4: dimension of the hexagonal hole= 4 mm. PN 10/16-5: dimension of the hexagonal hole= 5 mm. FWZ DN 50 - 250 Magnet filter for volume measuring unit of energy meters WMF DN 50 - 250 Headloss curves PN 10-4 and PN 16-4 PN 10-5 and PN 16-5 Nominal diameter DN mm 50 65 80 100 125 150 200 250 Length L mm 200 200 225 250 250 300 350 450 Height H mm 176 193 224 234 245 277,5 363 395 Flange connected D mm 165 185 200 220 250 285 340 395 Bolt circle D1 mm 125 145 160 180 210 240 295 350 Screws Hole diameter pc. mm 4 Ø19 4 Ø19 8 Ø19 8 Ø19 8 Ø19 8 Ø23 8 Ø23 12 Ø23 Weight kg 12,4 13,8 15,1 17,7 26,9 35,8 58,5 95 Technical data 9 Bulk Water Meter ZF-series Combined honeycomb rectifier the measurement is not falsified. This problem occurs if a meter is installed immediately after a valve bend in the pipe or if several pumps feed one collecting pipe. Perfect measuring results in Woltman meters require that the water strikes the meter at a steady flow. In order to prevent excessive turbulence in flow, stabilizing sections in front of the meters are prescribed prescribed. This task is also carried out by the flow straighteners which are fitted in front of and behind the meter. A honeycomb rectifier solves this problem. 32 square axial-flow channels destroy the angular momentum of the water inside the pipeline. Located at the inlet of the honeycomb section is a perforated disc whose cross section is approximately half the size of the cross section of the pipe. The inflowing water is damped and the square channels which follow destroy any angular momentum. The head loss caused by the honeycomb rectifier at a flow rate of 3 m/sec is approximately 0.1 bar. The metal flange on the perforated disc is used to secure the rectifier between two flanges with the honeycomb section pointing in the direction of flow. A length of blank pipe at least 5 pipe diameters should be fitted in front of the meter. If the rectifier is positioned at a short distance in front of the meter then minus-range deviations in measurements can occur. The honeycomb rectifier is made of stainless steel. Should, however, an irregular rate of flow occur in the pipe cross section, other or additional measures must be taken so that the result of Scanning sensors Applicable with all WPH-ZF and WS-ZF Opto sensor IG-IR Pulse rates 10 DN 50 - 500 mm Reed sensor KG-R Namur sensor IG-IN Pulser Pulse valence DN 40 .. 125 Pulse valence DN 150 .. 300 Pulse valence DN 400 .. 500 Reed sensor KG-R 0,1 and 1 m³ 1 and 10 m³ 10 and 100 m³ Opto sensor IG-IR 0,001 m³ 0,01 m³ 0,1 m³ Namur sensor IG-IN 0,001 m³ 0,01 m³ 0,1 m³ PuIse counter module IZM 208 The IZM 208 pulse counter module can take the inputs of up to 3 pulse output meters and integrate them into a bus system. King-sized connectors, mural or DIN rail mounting as well as several optional or retrofittable function modules allow the user to solve every kind of metering demand. Key features include: Flow rate averaged over the last 30 minutes. Even if pulses are 30 minutes apart, the algorithm will continue to deliver an accurate averaged flow rate. Data logging with user configurable storage of samples to maximise capacity. Using plug-in modularity, memory can be easily upgraded. The pulse streams are increased with the builtin 230 V power supply module. Due to this, interferences are minimized and impulse pipes can be longer. All devices are supplied with an optical interface for mobile data logging along with programming of the specific parameters. The option of RS232, ZR-Bus, M-BUS, radio module 433 MHz or 868 MHz - all from the one unit. A non-volatile memory captures and saves at regular intervals all essential data. Operating failures and errors are detected automatically and can be shown on the local display with date, duration and type of error. Furthermore, the integrated data logger allows access to further stored data which is not accessible on the display. Due to the integrated clock and calendar, specified reading date (S.R.D.) data are also no problem for our IZM 208 pulse counter module. The volumes of the meters are written into the memory on the date specified by the user year after year and can be read or transmitted remotely. As well as displaying consumption data on the local register, the IZM 208 also makes this data available on the bus when requested. Low-cost pulse output meters can be used to establish an M-Bus network without the high cost normally associated with M-Bus compatible meters. Dimensions The robust plastic body of the pulse counter module, the circumferential o-ring nut and the PG-fitting with plastic segment insets provide ideal protection for the electronic system against water. If fittings are not used, standard mounted hole plugs or hard plastic plugs prevent dirt and moisture from entering. Datamanagement with ZENNER softwares. The pulse counter module can work together with all meters. sizes of meters 11 Bulk Water Meter ZF-series Pulse counter module Communication module Retrofittable for 230 volt power supply Standard optical interface Menus can be configured More flexible user-specific menu structure Invisible service mode for end-user The pulse counter module IZM 208 can be ordered with additional modules. Subsequent retrofitting of the modules is also possible. In this connection, the combinations shown here are possible. The sequence of the retrofittable modules is though the predetermined raster of the mounting drill holes uncritical, however only one interface may be mounted in each case. interface module (M-Bus, RRS-232, S-232, Z R-Bus) supply module 230 V The following modules can be ordered or are retrofittable: platinum base memory module 3 point direct D I N rail mounting 230V Supply module: Interface module: M-Bus RS 232 ZR-Bus Radio wave module 433 MHz Radio wave module 868 MHz 3 x PG9 Memory module LP: Mounting solutions 8K 32K 96K 3 x PG7 The pulse counter module allows 3 starting points for a reliable wall installation installation. The upper wall hook resp. the lateral long holes are designed for screws with a shaft diameter of up to 5 mm. The dimensions of the body 130 x 175 x 55 mm and the alignment of the connection points also allows a Display sequences Main menu IP68 convenient connection also onto e-counter mounting fields. DINdisplay rail(only installation AError if present) is also possible in switch cabinets with our snap-spring mounting set SFHM4 which is also available as an accessory (order no. 65L 094). Main volume meter Additional volume 1 Level 1 Additional volume 2 Error display (only if present) Segment test (flashing) Main volume meter Flow rate Additional volume 1 Operating hours Additional volume 2 Technical data Microprocessor energy indicator Segment test (flashing) Ambient temperature Display Measuring units Power supply 12 m³ / l built-in 6 year battery (3V or 3.6 V) or transformer Current on contact impulse IP rating 5°C ... 50°C 8-digit, floating decimal point Flow rate Operating hours IP65 ~1 µA / 1 mA by 230 V power supply IP 65, corresponding to DIN 40050 Data transmission PC, Windows CE® powered Pocket PCs or PSION workabout®, modem, radio Meters are being increasingly read electronically over a communications network. In the future, all meters will be read automatically. ZENNER has the technology today to achieve this goal in the future. For the W-ZF meter series, 4 systems of meter reading are available. 1. “On-Site” reading where the reading is taken at or near the location of the meter. This can be performed using our hand-held terminal (Psion, Ipaq) or using a PC. 2. Automated meter reading where the meter is read fully automatic using modems. 3. Radio reading where radio waves are used to transmit the read-out from the meter, using for example the unidirectional compact radio wave module RDM 802 for reading Woltman meters installed in shafts. 4. Remote reading by a battery-operated GSM module for meters when access to the meter location is difficult. Data transmission via GSM modem in predetermined, programmable intervals. ZENNER recognizes that hardware is only a small part of a meter reading system. In some regards, good software is the most significant component of a meter reading system. Therefore ZENNER has developed software with the aim of making the transition from meter reading to the billing system as smooth as possible. Our software development concept is an open and modular software concept called Global Meter Management (GMM). ZENNER’s approach to data processing can be summarised as follows: Suitable instrument selection Windows CE® powered Pocket PC with software package GMM (Global Meter Management) Seamless data utilisation from meter to application Portable software Open interface Simple operation Inexpensive and efficient RDM 802-PK-LP 13 Bulk Water Meter ZF-series Ordering data for WPH meters Model Nominal diameter DN m³/h Length l / pulse Type Order-No. WPH-K-ZF-N... WPH-K-ZF-N 15 40 200 mm can be chosen ...030200040FL 12B 169 15 50 200 mm can be chosen ...030200050FL 12B 055 25 65 200 mm can be chosen ...050200065FL 12B 056 40 80 225 mm can be chosen ...080225080FL 12B 057 60 100 250 mm can be chosen ...120250100FL 12B 058 100 125 250 mm can be chosen ...200250125FL 12B 103 150 150 300 mm can be chosen ...300300150FL 12B 059 250 200 350 mm can be chosen ...500350200FL 12B 060 400 250 450 mm 10000 ...800450250FL 12B 061 600 300 500 mm 10000 ...1200500300FL 12B 135 1000 400 600 mm 10000 ...2000600400FL 12B 136 1500 500 800 mm 10000 ...3000800500FL 12B 137 WPH-W-ZF-N 15 50 200 mm can be chosen ...030200050FL 12B 071 standard version pulser can be retrofitted available up to DN 200 25 65 200 mm can be chosen ...050200065FL 12B 158 40 80 225 mm can be chosen ...080225080FL 12B 159 60 100 250 mm can be chosen ...120250100FL 12B 160 100 125 250 mm can be chosen ...200250125FL 12B 161 150 150 300 mm can be chosen ...300300150FL 12B 162 250 200 350 mm can be chosen ...500350200FL 12B 163 WPH-K-ZF-I-N 15 40 200 mm 1000 ...030200040FL 12B 181 pulse version complete with pulser KG-ZR, available up to DN 500 15 50 200 mm 1000 ...030200050FL 12B 062 25 65 200 mm 1000 ...050200065FL 12B 138 40 80 225 mm 1000 ...080225080FL 12B 139 60 100 250 mm 1000 ...120250100FL 12B 140 standard version pulser can be retrofitted available up to DN 500 WPH-K-ZF-N PN 10/16 30°C WPH-W-ZF-N... WPH-W-ZF-N PN 10/16 90°C WPH-K-ZF-I-N... WPH-K-ZF-I-N PN 10/16 30°C 100 125 250 mm 1000 ...200250125FL 12B 141 150 150 300 mm 10000 ...300300150FL 12B 142 250 200 350 mm 10000 ...500350200FL 12B 143 400 250 450 mm 10000 ...800450250FL 12B 144 600 300 500 mm 10000 ...1200500300FL 12B 145 1000 400 600 mm 10000 ...2000600400FL 12B 146 1500 500 800 mm 10000 ...3000800500FL 12B 147 WPH-W-ZF-I-N 15 50 200 mm 1000 ...030200050FL 12B 182 pulse version complete with pulser KG-ZR, available up to DN 200 25 65 200 mm 1000 ...050200065FL 12B 183 40 80 225 mm 1000 ...080225080FL 12B 184 60 100 250 mm 1000 ...120250100FL 12B 185 100 125 250 mm 1000 ...200250125FL 12B 186 150 150 300 mm 10000 ...300300150FL 12B 187 250 200 350 mm 10000 ...500350200FL 12B 188 WPH-W-ZF-I-N... 14 WPH-W-ZF-I-N PN10/16 90°C Ordering data for WS meters Model Nominal diameter DN m³/h Length l / pulse Type Order-No. WS-K-ZF-N... WS-K-ZF-N PN 10/16 30°C 15 50 270 mm can be chosen ...030270050FL 11B 025 WS-K-ZF-N 25 65 300 mm can be chosen ...050300065FL 11B 026 40 80 300 mm can be chosen ...080300080FL 11B 027 standard version pulser can be retrofitted 60 100 360 mm can be chosen ...120360100FL 11B 028 150 150 500 mm can be chosen ...300500150FL 11B 029 15 50 270 mm can be chosen ...030270050FL 11B 036 WS-W-ZF-N 25 65 300 mm can be chosen ...050300065FL 11B 098 40 80 300 mm can be chosen ...080300080FL 11B 078 standard version pulser can be retrofitted WS-W-ZF-N... WS-W-ZF-N PN 10/16 90°C 60 100 360 mm can be chosen ...120360100FL 11B 079 150 150 500 mm can be chosen ...300500150FL 11B 080 15 50 270 mm 1000 ...030270050FL 11B 030 WS-K-ZF-I-N 25 65 300 mm 1000 ...050300065FL 11B 064 40 80 300 mm 1000 ...080300080FL 11B 065 pulse version complete with pulser KG-ZR, available up to DN 150 WS-K-ZF-I-N... WS-K-ZF-I-N PN 10/16 30°C 60 100 360 mm 1000 ...120360100FL 11B 066 150 150 500 mm 10000 ...300500150FL 11B 067 15 50 270 mm 1000 ...030270050FL 11B 099 WS-W-ZF-I-N 25 65 300 mm 1000 ...050300065FL 11B 100 40 80 300 mm 1000 ...080300080FL 11B 101 pulse version complete with pulser KG-ZR, available up to DN 150 60 100 360 mm 1000 ...120360100FL 11B 102 150 150 500 mm 10000 ...300500150FL 11B 103 WS-W-ZF-I-N... WS-W-ZF-I-N PN 10/16 90°C All WS meters are available in length according to ISO standard 15 Bulk Water Meter ZF-series Ordering data for accessories Model Description Type Order No. Standard IZM208-ST 50W276 Pulse counter module IZM 208 for M-Bus IZM208-BM 50W274 (All pulse counter moduls are also available with mains connection) for ZR-Bus IZM208-BZ 50W177 for RS232 IZM208-BR 50W275 RDM 802-PK-LP 65L150 Type Order No. Radio wave module RDM 802 (version with cable) Model for Woltman meters Packing unit Pcs. DN Length Reed sensor for type ZF-N 1 KG-R 65B 006 Opto sensor for type ZF-N 1 IG-IR 65B 008 Namur sensor for type ZF-N 1 IG-IN 65B 009 50 WGR-050 65B 010 65 WGR-065 65B 011 Combined honeycomb rectifier Filter for Woltman meter for cold water 30° C Magnetfilter for Woltman meter for hot water up to 150° C 1 1 80 WGR-080 65B 012 100 WGR-100 65B 013 125 WGR-125 65B 014 150 WGR-150 65B 015 200 WGR-200 65B 018 50 PN 10-4 200 FWZ-050 65B 019 65 PN 10-4 200 FWZ-065 65B 034 80 PN 10-4 225 FWZ-080 65B 020 100 PN 10-4 250 FWZ-100 65B 021 125 PN 10-4 250 FWZ-125 65B 035 150 PN 10-4 300 FWZ-150 65B 031 200 PN 10-4 350 FWZ-200 65B 032 250 PN 10-4 450 FWZ-250 65B 037 50 PN 10-4 200 WMF-050 65B 041 65 PN 10-4 200 WMF-065 65B 042 80 PN 10-4 225 WMF-080 65B 044 100 PN 10-4 250 WMF-100 65B 045 125 PN 10-4 250 WMF-125 65B 046 1 150 PN 10-4 300 WMF-150 65B 047 200 PN 10-4 350 WMF-200 65B 048 250 PN 10-4 450 WMF-250 65B 049 N°97A006_060303GB For further detailed information on the CHEKKER® system request our brochure „ System CHEKKER® “ . 16 All rights to technical modifications reserved. We accept no liability for any mistakes or printing errors. ZENNER® is a registrated trademark of ZENNER GmbH & Co. KGaA..