OUTLINE - Pinnacle Architectural Lighting
Transcription
OUTLINE - Pinnacle Architectural Lighting
EDGE OUTLINE E V O L U T I O N LED Recessed Linear Perimeter Slot System Project Name Date Catalog Number Type CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Extruded alumi- num module with reflector and lens for perfect perimeter illumination. ELECTRICAL Electronic, 120 to 277 volt input and 36V output. 0-10 volt dimming standard. LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80. R9≥20, 27K is CRI≥91, 30K, 35K, and 40K is CRI≥83. Minimum lifetime greater than 60,000 hours. MOUNTING Edge Evolution is designed to install into acoustical grid and inaccessible ceilings. Specify GX, FL, SF, NF for individual and continuous runs (runs designed to fall on-grid). Consult factory for detailed installation instructions. FINISH Standard powder-coat textured white, metallic silver, textured black, graphite or bronze painted finish on exposed trim. Driver cover to be painted standard white when custom color specified. Consult factory for custom colors. WARRANTY Edge Evolutuion LED offered with a 5-year limited warranty. Covers LED, driver and fixture. LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted. Standard (EVL) YEAR LED WARRANTY LFL 4-1/2” (114.3mm) 4-1/2” (114.3mm) LED Convertible Convertible LED YEAR LED WARRANTY LFL LFL LED Convertible LED LFL EVL L U M I N A I R E S P E C I F I C AT I O N EVL_- ____- ___’- ___- HOUSING COLOR/LUMENS LENGTH MOUNTING ___- VOLTAGE Convertible 120- 120 V LED 277- 277 V 347- 347 V UNV- UNV (120-277) Sample Catalog #: EVL-30-24’-FL-120-1C-W EVLS __- YEAR LED WARRANTY 1 LFL 27K Color Temperature Lumen Options 2727K, 164 lumens/ft (4.0 watts/ft) 27HO- 27K, 313 lumens/ft (6.0 watts/ft) 27VHO- 27K, 404 lumens/ft (8.0 watts/ft) 30K Color Temperature Lumen Options YEAR LED 3030K, 200 lumens/ft (4.0 watts/ft) WARRANTY 30HO- 30K, 381 lumens/ft (6.0 watts/ft) 30VHO- 30K, 492 lumens/ft (8.0 watts/ft) 35K Color Temperature Lumen Options LFL 3535K, 209 lumens/ft (4.0Convertible watts/ft) 35HO- 35K, 398 lumens/ft (6.0 watts/ft)LED 35VHO- 35K, 514 lumens/ft (8.0 watts/ft) 40K Color Temperature Lumen Options 4040K, 214 lumens/ft (4.0 watts/ft) 40HO- 40K, 409 lumens/ft (6.0 watts/ft) 40VHO- 40K, 527 lumens/ft (8.0 watts/ft) 4-1/4” (107.9mm) 5-1/4” (133.4mm) Convertible EVL- Edge Evolution Outline EVLS- Edge Evolution Outline Shallow Shallow (EVLS) CIRCUITING __- ____ FINISH OPTIONS LED Convertible Circuit 1C- Single LFL 1D- Single Circuit Dimming5 1B- Single Circuit with Battery Pack5, 6,11 1E- Single Circuit with Emergency Circuit11 Acoustical Grid Ceiling G1- 1” (25.4mm) Ceiling Grid G9- 9/16” (14.3mm) Ceiling Grid Convertible GS-LFL Screw Slot Ceiling Grid GB- 9/16” (14.3mm) Ceiling Grid with Bevel Trim Inaccessible Ceiling FL- Standard 1/2” (12.7mm Flange SF- Spackle Flange NF- Flangeless4 LED RGB LED10 RGBX- RGB LED with DMX Controller Custom Output CL_____- Specify color temp. and lumens/ft. (i.e. CL35300) CW____- Specify color temp. and wattage/ft. (i.e. CW407) (Specify lumens/watts between standard offering listed above. Lumens are specified per color temp.) Individual Units2 2- 2’, 23” (584.2mm) fixture2 3- 3’, 35” (889mm) fixture2 4- 4’, 47” (1,193.8mm) fixture2 6- 6’, 71” (1,893.4mm) fixture2 8- 8’, 95” (2,413mm) fixture2 QS- Quick Ship13 CP- Chicago Plenum GLR- Internal Fast blow fuse LGR- Low Glare Reflector12 C90I- 90˚ Inside Corner7,11 C90O- 90˚ Outside Corner7,11 C45I- 45˚ Inside Corner7,11 C45O- 45˚ Outside Corner7,11 EF- End Filler8 SW- Step Switching W- Matte White S- Metallic Silver (rails only)9 BL- Textured Black (rails only)9 GR- Graphite (rails only)9 BR- Bronze (rails only)9 CC- Custom Color (rails only)9 Continuous Runs3 xx’-Specify row length to 1’ (304.8mm) increments See back page for mounting detail. 2Individual units shipped with end plates uninstalled. 3Continuous runs made up of both even and odd length fixtures. Designed to fall on-grid. 4NF to be utilized for metal pan / millwork ceiling. 5Some Edge configurations will not accommodate all electrical options. Consult factory. 6Integral battery packs with remote test switch are provided with 1B option. Available in 4’ or longer lengths. 7See back page for corner details. 8End Filler option used for fitting fixture into odd lengths. Filler is non-illuminated. Left and right end filler provided whe EF specified. 9Custom Color will be on fixture rails only. 10Osram/Sylvania Color Changing RGB LED and components are for accent or decorative lighting and does not provide room illumination. See back page for more information. 11Submittal drawings required. 12Low Glare Reflector (LGR) required on any layout with inside corner. LGR softens glare and changes polar cuvre and does effect lumen out put and efficacy, see back page for photometry. 13 Includes EVL, EVLS, all sizes, continuous runs, G1G and FLF mounts, UNV, 120 or 277 voltage, std white finish, 1C, 1D, and 1B circuiting, Chicago plenum, and GLR. 1 Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® March 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previous printed or electronic versions. PHOTOMETRICS EV_L 873 720 655 540 437 360 218 180 Test #: ITL84679 Part #: EVL-35HO-4 Lumens per watt: 66 Total Delivered Lumens: 1592 Test #: ITL84682 Part #: EVL-35HO-4-LGR Lumens per watt: 57 Total Delivered Lumens: 1376 EV3WG INDIVIDUAL AND CONTINUOUS RUN MODULES 1 1” Grid Mounting Options 23" (584.2mm) G1 G1 2' 9/16” Grid Mounting Options Screw Slot and 9/16” Mounting Flange Detail G9 FL G9 GS GS Non-Flange NF Spackle Flange SF (1) module per 2' unit 35" (889mm) 3' 71” (1893.4mm) or 72” (1828.8mm) Specify (1) module per 3' unit G1 in Mounting section of part #. 47” (1193.8mm) or 48” (1219.2mm) Specify G9 in Mounting section of part #. 6' Specify GS in Mounting section (2) modules per 6' unit of part #. Specify FL of part #. Specify NF of part #. 95” (2413mm) or 96” (2438.4mm) Specify SF of part #. 8' 4' (2) modules per 8' unit (1) module per 4' unit 1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings. MOUNTING 1” Grid Mounting Options G1 G1 Specify G1 in Mounting section of part #. 9/16” Grid Mounting Options G9 G9 Specify G9 in Mounting section of part #. APPLICATION GUIDELINES Screw Slot and 9/16” Mounting GB GS Flange Detail GS Specify GS in Mounting section of part #. Non-Flange FL NF Specify FL of part #. Specify NF of part #. Spackle Flange SF Specify SF of part #. INSTALLATION Reflector Low Glare Reflector Outline easily installs into acoustical grid and inaccessible ceiling. Install wall rail onto wall and hook fixture onto rail. Tie off fixture to structure. MUST BE INSTALLED PRIOR TO CEILING INSTALLATION. See installation instructions for detailed information. CORNERS 18”-20” Illumination 45° Inside 45° Inside 90° Inside End Filler 5° Outside 45° Outside 90° Outside 90° Outside Outline is designed to install flush against the wall. MUST BE INSTALLED PRIOR TO CEILING INSTALLATION. See installation instructions for detailed information. 90° Inside Pinnacle Lighting’s Outline is a complete perimeter lighting solution. The inside, outside corners, and end fillers allow designers to Outline a space. The 45 degree and 90 degree corners allow for +/- 5 degrees of adjustability to accommodate any wall imperfections. Specify runs to the nearest foot and non-illuminated corners are slid into place to finish the perimeter lighting. Minimum distance for corners is 5-1/2” from the wall, with a max of 12” away from the wall. The End Fillers have a maximum of 6” per end. See installation instructions for detailed information. End Filler Inside Corner Outside Corner Detail Detail Detail Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® March 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. Edge Evolution Outline Row layout with End Fillers Edge Evolution Outline end fillers allow for wall-to-wall fixture installation. The fillers are installed to the end of the row filling the gap between the fixture end and the wall. End fillers are designed to be installed at the beginning and end of the row for optimal light distribution along the wall. Below are typical rows built of standard fixture lengths with end fillers at each end. The end fillers can increase a row length between 1” to 12” on either side with 1” to 6” being the optimal length to either end. When ordering rows with end fillers, specify the illuminated row length in the LENGTH section of the part number and EF in the OPTIONS section of the part number for the End Fillers. Sample catalog #; EVL-30-24-G1-120-1D-W-EF Nominal Fixture Lengths Actual Fixture Lengths Illuminated Length 2’ 23” 3’ 35” 4’ 47” or 48” 5’ 59” Row Layout with End Fillers 2’ EF 3’ EF 4’ EF 5’ EF 6’ EF 7’ EF 8’ EF 9’ EF 72” 10’ EF 72” 11’ EF 96” 12’ EF 96” 13’ EF 14’ EF 96” 15’ EF 96” 16’ EF 96” 17’ EF 96” 72” 18’ EF 96” 72” 19’ EF 96” 96” 20’ EF 96” 96” 21’ EF 96” 22’ EF 96” 96” 23’ EF 96” 96” 24’ EF 96” 96” 25’ EF 96” 96” 23” EF EF 35” 47” EF 59” EF 71” EF 48” 35” EF 95” EF 35” EF 47” 72” EF 35” EF 47” 48” EF 35” EF 71” EF 48” 35” EF 95” EF 35” EF 47” 72” EF 35” EF 47” EF 48” PINNACLE ARCHITECTURAL LIGHTING™ 12655 East 42nd Avenue, Suite 50 Denver, Colorado 80239 35” EF 71” EF 48” 35” EF 95” 72” Ph 303.322.5570 EF 35” Fax 303.322.5568 EF 6’ 71” or 72” Min. Length Optimal Length Max. Length 2’-1” 2’-11” 3’-11” 3’-1” 3’-11” 4’-11” 4’-1” 4’-11” 5’-11” 5’-1” 5’-11” 6’-11” 6’-1” 6’-11” 7’-11” 7’-1” 7’-11” 8’-11” 8’-1” 8’-11” 9’-11” 9’-1” 9’-11” 10’-11” 10’-1” 10’-11” 11’-11” 11’-1” 11’-11” 12’-11” 12’-1” 12’-11” 13’-11” 13’-1” 13’-11” 14’-11” 14’-1” 14’-11” 15’-11” 15’-1” 15’-11” 16’-11” 16’-1” 16’-11” 17’-11” 17’-1” 17’-11” 18’-11” 18’-1” 18’-11” 19’-11” 19’-1” 19’-11” 20’-11” 20’-1” 20’-11” 21’-11” 21’-1” 21’-11” 22’-11” 22’-1” 22’-11” 23’-11” 23’-1” 23’-11” 24’-11” 24’-1” 24’-11” 25’-11” 25’-1” 25’-11” 28’-11” www.pinnacle-ltg.com Shown are typical configurations utilizing standard product, and may not produce optimal lighting effects using Max. Length layouts will result in dark spots at the ends of your runs. 8’ 95” or 96” March 2016 © 2016 Pinnacle Architectural Lighting™ Edge Evolution Outline Row layout with End Fillers PLAN VIEW 45° Inside End Filler 90° Inside 45° Outside 90° Outside 45° Inside 45° Outside 90° Inside Connector Part Number Min. Length Max. Length End Filler EF 1” 12” 45° Outside Corner C45O 3/8” 9-11/16” Begining of Row 90° Outside C45I 45° Inside Corner 4-1/4” 11-5/8” End Filler 90°Inside Corner C90I 7” 13” 90° Outside Corner C90O 0” 9-1/2” End Filler End Fillers - Designed to be adjustable to allow a standard fixture to fit into a wall-towall opening. ie. If you have an opening that is 51” order a 4’ (47”) fixture and End Fillers to fill in 2” inches on either side. Outside Corners - Designed to go around outside corners allowing you to light a straight wall turn a corner and light another wall. (Numbers shown Joining Fixture are wall dimension) Inside Corners - Designed to go into inside corners allowing you to light a straight wall turn a corner and light another wall. Rough in for outside corner is from begining of row length to far end of joining fixture. Begining of Row Joining Fixture PINNACLE ARCHITECTURAL LIGHTING™ 12655 East 42nd Avenue, Suite 50 Denver, Colorado 80239 Ph 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com Shown are typical configurations utilizing standard product, and may not produce optimal lighting effects using Max. Length layouts will result in dark spots at the ends of your runs. March 2016 © 2016 Pinnacle Architectural Lighting™