SUBMITTAL COVER SHEET UNIT SUMMARY PROJECT NAME LOCATION

Transcription

SUBMITTAL COVER SHEET UNIT SUMMARY PROJECT NAME LOCATION
SUBMITTAL COVER SHEET
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY
DATE
UNIT SUMMARY
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES:
NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
FORM NO. X33-1406
(-)ANL- SERIES – AIR CONDITIONERS
EFFICIENCIES UP TO 14.5 SEER/12.5 EER
NOMINAL SIZES 1.5-5 TONS [5.27-17.58 kW]
JOB NAME
UNIT MODEL NO.
CONTRACTOR
COIL MODEL NO.
ENGINEER
AIR HANDLER MODEL NO.
SUBMITTED FOR
APPROVAL
RECORD
DATE
LOCATION
ORDER NO.
UNIT DATA
FEATURES FOR (-)ANL- SERIES
COOLING PERFORMANCE
• This unit contains a special scroll compressor that is designed specifically to
operate with R-410A refrigerants and polyolester (POE) oils. The compressor
is hermetically sealed and incorporates internal high temperature motor
overload protection and durable insulation on the motor windings. It is
externally mounted on rubber grommets to reduce vibration and noise.
• Compressors have an internal pressure relief assembly to protect against
excessive pressure differential.
• All refrigerant connections are on the exterior of the unit, located close to the
ground for neat appearing installations.
• Cabinet is constructed of powder painted galvanized steel. The full wraparound louvered grille protects the coil from damage.
• Copper tube—aluminum fin coils are used on all models.
• The control box is located in the top corner of the cabinet providing for easy
access through a service panel.
• Service valves are standard on all models.
• Power and control wiring are kept separate.
• Every unit is factory charged and tested.
• Separate compressor compartment for easy service access.
• Drawn, painted base pan for extra corrosion resistance and sound reduction.
• Automatic reset high and low pressure controls are standard on all models.
• A liquid line filter drier is standard on all models (shipped – not installed).
Conditional Parts ............................................................................Ten (10) Years
Compressor ....................................................................................Ten (10) Years
EFFICIENCY .................................. _______ SEER
TOTAL CAPACITY .................... _______ MBH [kW]
SENSIBLE CAPACITY .............. _______ MBH [kW]
OUTDOOR DESIGN TEMP. ........ _______ °F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL .............. _______ °F [°C] DB
_______ °F [°C] WB
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY .................. _______ CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT........................................ _______ IWC
MOTOR RATING .......................... _______ HP [W]
ELECTRICAL DATA
POWER SUPPLY .......................... ___________ Hz
MINIMUM WIRE SIZE ...................... _______ AWG
FIELD INSTALLED ACCESSORIES
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ............ _______ AMPS
Low Ambient Control ........................................................................................
Compressor Time Delay Control ......................................................................
Hard Start Components ....................................................................................
Compressor Crankcase Heater (CCH) ..............................................................
CLEARANCES
ACCESS SIDE
24" [609.6 mm]
AIR INLETS
6"
ABOVE UNIT
60" [1524 mm]
[152 mm]
16.0
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with
appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”
DIMENSIONS
Model Number
(-)ANL018
024/031
037/043
Height “H”
(Inches) [mm]
19 [483]
19 [483]
23 [584]
Length “L”
(Inches) [mm]
351/2 [902]
401/2 [1029]
443/8 [1127]
Width “W”
(Inches) [mm]
233/4 [603]
275/8 [702]
311/2 [800]
049
060
29 [737]
33 [838]
443/8 [1127]
443/8 [1127]
311/2 [800]
311/2 [800]
[ ] Designates Metric Conversions
AIR DISCHARGE
ALLOW 60⬙ [1524 mm] CLEARANCE
W
L
ACCESS
PANEL
H
AIR INLETS
(LOUVERS)
ALLOW 6⬙ [152 mm]
MIN. CLEARANCE
3 SIDES
A-0
0001
ALLOW 24⬙ [610 mm]
ACCESS CLEARANCE
SPECIAL NOTES ON EQUIPMENT:
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
RHEEM
MANUFACTURING
COMPANY
5600 Old Greenwood Road, Fort Smith, Arkansas 72908
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A.
10-12 QG
FORM NO. X33-1406
Supersedes Form No. X33-1220 Rev. 2