KG 4304 KG 4305 KG 4308 KG 4309
Transcription
KG 4304 KG 4305 KG 4308 KG 4309
EN DE EN DE - KG 4304 KG 4305 KG 4308 KG 4309 KG 4310 KG 4315 Seifert Systems Ltd. HF 09/10 Hal Far Industrial Estate Birzebbuga, BBG 3000 Malta EN Guarantee DE Tel: +356 2220 7000 Fax: +356 2165 2009 [email protected] www.seifertsystems.com EN EN General - DE DE AlIgemein - - - 43050001 3 43080001 3 43083001 3 43090001 3 43093001 3 43100001 DE 43053001 3 EN 43043001 3 1~ 4 1 Mc Technische Daten / Technical data 43040001 3 3 3 43103001 3 43150001 3 43153001 3 EN EN C. T Maintenance DE DE C. EN Troubleshooting Mc BU BK GNYE WH BK BK BU External Blower BK BU GNYE BN GY RD PK Verify power supply Internal fan needs to be replaced Replace internal fan Enclosure air temperature below setting temperature (St) Verify value of parameter St Door switch contact is open Verify door switch Controller does not work Replace controller Internal fan works, external fan and compressor do not work. Display shows alternating “Off” and temperature The sequence of the phases inside the power supply connector is incorrect Change phases inside power supply connector External and internal fan work, compressor does not work Compressor motor electrical failure Verify external fan, verify ambient temperature, clean condenser Capacitor for compressor failed Replace capacitor Compressor works external fan does not work External fan needs to be replaced Replace external fan Compressor and fans (external and internal) work all the time Unit cooling undersized Enclosure needs a bigger cooling unit External fan and compressor work at intervals Thermal compressor protector triggered Verify ambient temperature, clean condenser Internal fan works, external fan and compressor do not work. BU Internal Blowers BU BK 1 460V 2 400V 400V L1 3 5 460V L1 4 N/0 N / L2 5 6 115V EARTH 7 4 2 115V L1 230V ALARM P2 ALARM P1 9 8 Circuit Diagram KG 4304/05/08/09 0XXX rev D PR596019703 ECN 14/03/15 Enclosure over heating AUTOTRANSFORMER 9 POLE CONNECTOR 9 POLE CONNECTOR 1 3 DOOR T1 1 DOOR T2 Internal Blowers BK BU BK LIVE BU 3 Solution There is no power on the unit BK BU External Blower GNYE BK NEUTRAL 4 2 EARTH 5 6 Cause Internal fan does not work 7 CORE CABLE BK BU BN PK RD GY GNYE BN BK BU 7 CORE CABLE BU GNYE 7 9 8 ALARM P2 DOOR T1 ALARM P1 DOOR T2 Condition Unit does not cool BN wire not present on KG4304 unit BK BU GNYE BN 2nd Sensor only on KG4305 units BN wire not present on KG4304 unit BU BK GNYE WH BK BK BU 2nd Sensor only on KG4305 units Failure Excessive condensate BU BK GNYE WH BK BK BU BU BK GNYE WH BK BK BU External Blower BK BU BK BU 4 5 460V 400V N/0 1 115V 2 2 400V L1 4 3 230V 460V L1 1 3 EARTH N / L2 115V L1 Speed Reducing Capacitor only for 4310XXX AUTOTRANSFORMER Ciruit Diagram KG 4310/15 3XXX rev E PR596019702 ECN 14/06/08 Speed Reducing Capacitor only for 4310XXX BK 9 POLE CONNECTOR GNYE BN BN Internal Blower 1 4 3 LIVE EARTH NEUTRAL BK BU 2 GNYE Circuit Diagram KG 4310/15 0XXX rev D PR596019700 ECN 14/03/15 GNYE BN 7 CORE CABLE 5 6 BK 7 BU ALARM P2 ALARM P1 9 8 BN DOOR T1 GY DOOR T2 GNYE PK GNYE RD BU External Blower GNYE BU BN 5 6 BK 7 7 CORE CABLE ALARM P2 ALARM P1 9 8 BK BN DOOR T1 BU GY DOOR T2 GNYE PK RD 9 POLE CONNECTOR Contact dealer/service center Ambient air get into the enclosure Ensure door is closed, add a door switch and connect it to controller Door enclosure closed Enclosure IP degree minimum IP54 Seal openings on enclosure Damaged misplaced sealing strip Repair strip accordingly DE Fehlerbehebung Mc 1 2 3 5 6 4 7 8 9 11 10 1~ CONTROLLER Mc 1 2 3 5 6 4 7 8 9 11 10 1~ CONTROLLER Refrigerant leakage Door enclosure closed Ciruit Diagram KG 4304/05/08/09 3XXX rev E PR596019704 ECN 14/06/08 Fehler Zustand Gerät kühlt nicht Interner Lüfter arbeitet nicht. Ursache Keine Netzspannung am Gerät. Interner Lüfter muss ersetzt werden Interner Lüfter arbeitet, Schranktemperatur liegt Aussenlüfter und Verdichter unter der Eichtemperatur des funktionieren nicht. Thermostats. Abhilfe Stromversorgung untersuchen Internen Lüfter ersetzen Keine Gerätestörung. Zur Überprüfung der Testfunktionen den Eichpunkt des Thermostats soweit herunterstellen, dass Verdichter und Aussenlüfter anspringen. Danach den Eichpunkt wieder zurückstellen. Türkontaktschalter ist offen. Überprüfen Sie denn Türkontakt. Steuerung funktioniert nicht. Steuerung ersetzen. Interner Lüfter arbeitet, Die Reihenfolge der Phasen Wechseln Sie die Aussenlüfter und Verdichter im Anschlusstecker ist falsch Reihenfolge der Phasen im arbeiten nicht. Anschlusstecker Display zeigt abwechselnd AUS und Temperatur an. Aussen- und Innenlüfter Verdichtermotor hat Aussenlüfter überprüfen, arbeiten, Verdichter arbeitet elektrischen Fehler. Umgebungstemperatur nicht. überprüfen, Verdichter reinigen. Kondensator des Verdichters Kondensator ersetzen. defekt Verdichter funktioniert, Aussenlüfter muss ersetzt Aussenlüfter muss ersetzt Aussenlüfter funktioniert werden. werden. nicht. Kühlung Verdichter und beide Lüfter Kühlgerät zu klein Das Kühlgerät durch ein unzureichend (aussen / innen) arbeiten (unterdimensioniert) für die Gerät mit höherer Leistung ständig. im Schaltschrank ersetzen abgestrahlte Wärme Aussenlüfter und Verdichter Wärmeschutzschalter im Umgebungstemperatur funktionieren in Intervallen. Inneren des Verdichters hat überprüfen, Verdichter angesprochen. reinigen Kühlmittel undicht. Bitte den Kundendienst kontaktieren Zuviel Kondens- Schaltschranktüre offen. Umgebungsluft gelangt ins Stellen Sie sicher das die wasserbildung Schaltschrankinnere. Türe geschlossen ist, fügen Sie einen Türkontaktschalter hinzu und verbinden Sie ihn mit der Steuerung. Schaltschranktüre Der Schutzgrad des Keine Gerätestörung. geschlossen. Schrankes ist kleiner als Öffnungen im Schaltschrank IP54. wie z.B. Kabeldurchgänge hermetisch verschliessen. Die Dichtung zwischen Hermetisch verschliessen. Schaltschrank und Kühlgerät ist nicht richtig angebracht. Doc. No. 597700000 Rev 1.7 09/2014 1 2 3 4 5 6 7 8 9 11 10 1~ CONTROLLER Mc 1 2 3 4 5 6 7 8 9 11 10 1~ CONTROLLER