1.
Technical System of Technodrain
2.
Advantages over Traditional Systems
•
•
The channel represents the technology of Technodrain from Asoplast, demonstrating decades of
experience by their designers in the field of drainage. All solutions techniques and construction
details were marked to provide an end –user product that is light, safe and easy to install.
Technodrain wins the challenge compared to traditional systems, thanks to its versatility and
affordability of installation, strength and durability of its structure. The HDPE (High Density
Polyethylene) makes it light weight and immune to chemical attack.
•
Light weight compared to size, cost of transport and installation.
Robust,unbreakabletobumpsandfalls.
Technodraincanbeusedinthefieldtemperaturefrom-60°Cto+100°Cwithout
damage.
Chemicallyresistsawiderangeofacids,saltsandhydrocarbons.Technodraincan
also be used in special environments such as chemical plants, workshops and
service stations and is particularly suitable for roads with use of intensive salt
anti-freeze,destructivetomosttraditionalsystems.
SurfaceresistancetomoldandmicroorganismsmeansTechnodraincanbeusedin
all structures that require high hygiene such as flooring in kitchens, food processing
industries, hospitals, etc.
Coefficientofpeakflows,thesurfaceareaoftheTechnodraindoesnotcreate
barriers to water flow and minimizes the storage of aggregates.
Thesystemisveryversatileasthesamechannelcanbeinstalledwithdifferent
grateoptionsfromClassAtoClassD.
Preformeddischargeoutletslocatedonthebottomandsidepanelsofthechannel,
allow quick and simple connection to storm water discharge pipes.
Thepossibilityofmountinggrooveswiththefixedgrate,makesitextremelyfastto
install. You can transport the pipeline system (channel and grate) already packaged
for quick use.
•
•
•
•
•
•
3.
ResistancetoChemicals
Listed below are some of the substances that do not affect the behaviour of HDPE
(High Density Polyethylene)
•Hydrochloricacid
•Mineraloils
•Sulfuricacid
•Sodiumchloride
•Aceticacid
•Sodiumphosphate
•Ethlyalcohol
•Causticsoda
•Ammoniasalts
•Petrol
•Diesel
•Soap solutions and industrial cleaning products.
National Customer Service Number:
13 1926
www.everhard.com.au
ADVICE FOR THE INSTALLATION OF TECHNODRAIN
DRAINAGE SYSTEM
Step1.LoadClassRequest
The first step in designing a drainage system is the choice of grate.These choices are
based on the characteristics of load resistance the channel grate must endure, the
architectural finish preferred, and the surface water capture characteristics in relation to
thesizeofthegrate.TheloadclassesforthegrateoptionsarespecifiedinAS:3996.
The Specifier should also pay attention to potential future changes of use of an area which
may be subject to heavy or construction loads (e.g.: Semi Trailers or earthmoving
equipment) which may necessitate selecting grates suitable for higher load class rating.
ClassLoadingsasperAS:3996arelistedbelow
Class
A 15kN
Peferred Usage of drainage system
Pedestrian areas and cycle paths
B80kN
Areas including footways, accessible to light vehicles.
C150kN
D210kN
E400kN
F600kN
Mallsandareasopentoslowandmovingcommercialvehicles.
Carriagewaysofroadsandareasopentocommercialvehicles.
General docks, carriageway roads, aircraft pavements.
Docks and aircraft pavements subject to high wheel loads.
G900kN
Docks and aircraft pavements subject to very high wheel loads.
Step 2. Design of drainage system
The collection and drainage system should be sized according to the rainfall and
meteorological characteristics of the site concerned, size, shape and slope of the
catchment area, type of surface used (asphalt, concrete, paving, lawn, etc.), and the
properties of the runoff liquid being captured.
Attention should also be paid to access roads or roofs that may concentrate water into the
catchment area being considered as the total flow to disposal will be the summation of all
these components.
National Customer Service Number:
13 1926
www.everhard.com.au
Step 3. Laying
The Technodrain channel and grate system requires a base of concrete thick enough to
spreadtheverticalandhorizontalthrustloadsinaccordancewiththeClassratingofthe
grate selected.
A. Preparing the ground for installation:
The excavation for the installation of the drainage system Technodrain must be
dimensioned taking into account the channel selected and thickness of concrete required
fortheabutmentandthesubstrateasgivenintable1.Inadditiontothesethicknesses(R
and S) the excavation should allow for the possible passage of pipes to the final drain
connection. The natural ground the drain is being laid in must have a bearing capacity
sufficienttosupporttheloadclassesselected.Itmaybenecessarytoincreasethe
bearing capacity by tamping down the foundation or providing some form of ground or soil
reinforcement. In particularly soft sub grades may be necessary to make the
concrete foundation wider to provide a greater support area.
Table1.Recommendedthicknessforsubgrade
and concrete abutments according to load
classes
ClassLoading
Thickness
A
B
D
R
100
100
150
S
100
100
150
Figure 1:
B.Concretebase
The bedding must be prepared to provide for a concrete base thickness of S. The
oncrete to be used for the base of Technodrain must have flow properties conducive to the filling of
all cavities formed by the ribs external reinforcement channel for the same reason the size of
aggregatesinconcretecontentshouldnotexceedthediameterof15-18mm.
Image 1:
The minimum strength class of concrete for the foundation and abutment must be between 25 to
30MPaforgrateloadclasses(A10,B80,D210)and38to40MPafortheheavierloadclasses(E400,
F600,G900).Thereareanumberofpremixedmortarsinthemarketthatmaybeusedsuchas
MapegroutSVSikagrout312EmacoUltraRapidorsimilar.Forinstallationsincoldtemperatures,
Emaco Fast or similar can be used. These mortars also provide a low volume shrinkage of concrete
and reduce the time for transitability line drainage for road works with instant you can use premixed
mortartypeSikaPatch-4orsimilar.
National Customer Service Number:
13 1926
www.everhard.com.au
C.Installationofchannel
For the proper installation of the Technodrain channel, begin the installation from the point of discharge (well),
connecting the outlet to the stormwater system. For a perfect seal of the
male-femalejointontheTechnodrainchannelyoucanuseathixotropicbituminoustypesealantorSikaflex221
Adhesive. The channel should be installed with Technodrain grates already in place, it is therefore
recommendedtoperformthisoperationbeforelocatingthedrainintheexcavation.Careshouldbetakenin
ensuring the correct placement and orientation of grates on the channel before
tightening the fixing screws.
To connect storm water pipes to the Technodrain channel,
drill out the required size hole in the bottom, side or end
cap located on the channel using the appropriate sized
hole saw to suit the size of the discharging storm water
pipe.Removeanyroughedgeslocatedaroundtheinside
ofthechannel.InserttherequiredsizePVCpipefitting
onto the connection outlet of the channel and seal with
Sikaflex 221 adhesive or similar around the fitting and
channel.ConnectthestormwaterpipetothePVCpipe
fittingusinganapprovedPVCsolventcement.
It is extremely important to avoid distortion at the edge of the channel and subsequent
difficultieslocatingorremovingthegrate,orissuesgettingthewatertodraincorrectlytothegrateabutment.It
isrecommendedtoinstallacompressionorexpansionstripapprox40mmx8mmalongbothoutsideedgesof
the channel between the concrete and the Technodrain to allow for any expansion movement in either the
concrete or channel. During installation, avoid any damage to the grates and or the edge of the channel.
Pro200HChannel&Grate:Ensure that the galvanized clamps are embedded into the ubstrate or foundation of
the concrete envelope around the channel.
MagnumCity300Channel&Grate:For better anchorage of the channel, the insertion of steel rods of 8 to 12mm
in diameter into the connections located on the outside of the channel and embedded into the substrate or
foundation of the concrete envelope around the channel.
D. Final concreting
TheTechnodrainchannelabutmentsshouldthenbefilledwithconcretetoathicknessofR(Table1)asrequired
providing for the selected class load. It is also necessary to allow for any floor finishes such as tiles paving etc as it
isimportantthatthefinishedfloorremains3-5mmabovethefloordrainagegrate.
ForallloadclassesandespeciallytheD210kNclassandabove,theconcretefinishshallprotectthefinished
surface side of the support edge of the channel. It is important that the concrete is completely cured before
subjecting the channel to loads.
Table 2
1
A10
Concrete
Final Coating
National Customer Service Number:
13 1926
www.everhard.com.au
Concrete
Final Coating
SPECIFICATIONS
TechnodrainPro200HHDPEChannel&DuctileIronGrate
SupplyandinstallationofdrainagechannelforlineartypeTechnodrainPro200H,madefrom
HDPE (High Density Polyethylene) resistant to salts and acids solution. Structure of external
stiffening rib means integral with the body channel and the bottom of curvilinear structure.
Frame for mounting racks galvanized steel with a height not less than 25mm, thickness 4mm
and equipped with side clamps, bay system chassis to channel such that the monolithic final
fixing between channel frame and grate. Seat for the housing of the fastening fingers tight,
slots for the passage of screws closed to open only when necessary. Preformed outlets on
thebottomandsideswithdiametersupto160mm.
Dimensions (mm): Length1000mm,Internalwidth200mm,InternalDepth150mm.
ProductCode:81380
Product Description: TechnodrainPro200HHDPEChannel&DuctileIronGrate
(ClassD)x1m.
Weight: 22kg
DIMENSIONS
L
250
H
210
LN
200
Hi
150
DIAMETER 3xØ110
OUTLET
1xØ160
All dimensions are in mm.
National Customer Service Number:
13 1926
www.everhard.com.au
SPECIFICATIONS
TechnodrainEvomax150HChannel&GalvanisedGrate
SupplyandinstallationofdrainagechannelforlineartypeTechnodrainEvoMax150H,madefromHDPE
(High Density Polyethylene) resistant to salts and acid solutions. Structure of external stiffness rib means
integral with the body channel and bottom of curvilinear structure. Frame for mounting racks galvanized
steel with a height of not less than 25mm, thickness 2mm to provide support for channel edge. Galvanised
grates are to be locked down using galvanized tie down bars within the channel structure. Preformed out
letsonthebottomandsideswithdiametersupto160mm.
Dimensions(mm):Length1000mm,Internalwidth150mm,InternalDepth150mm
ProductCode:81471
ProductDescription:TechnodrainEvoMax150HHDPEChannel&GalvanisedGrate(ClassB)x1m
Weight: 9.9kg
DIMENSIONS
L
H
LN
200
209
150
Hi
150
DIAMETER
OUTLET
Ø110
Ø160
All dimensions are in mm.
National Customer Service Number:
13 1926
www.everhard.com.au
Technobox200HHDPESumpDrain&DuctileIronGrate
SupplyandinstallationoftheTechnobox200HSumpDrainmadefromHDPE (High Density Polyethylene) resistant to salts and acids in solution. Structure by
external stiffening ribs to the body well. Frame for mounting racks made ofgalvanized steel
with the height not less than 25mm, thickness of 4mm and equipped with side clamps,
system housing of the chassis the channel that makes the monolithic attachment final
between the channel frame and grate. Internal surfaces of flow path without right angles to
preventaccumulationofmudandinert.Thebuilt-trapsmustbecompletelyremovedto
allow full access to sump for cleaning. Possibility of staying permanently made of basket
performed sheet steel or galvanized steel for the collection of leaves or aggregates with a
diametergreaterthan10mm.Slotsforthepassageofscrewsclosedbeopenonlyif necessary.Preformedoutletsonbothsideswithdiametersupto200mm.
Dimensions (mm): Length500mm,ClearOpeningWidth200mm,InternalDepth427mm.
ProductCode:81381
Product Description: Technobox200HHDPESumpDrain&DuctileIronGrate
(ClassD)x500mm.
Weight: 13.1kg
OutletDiameters:2x100,160,200.
National Customer Service Number:
13 1926
www.everhard.com.au
TechnodrainMagnumCity300HDPEChannel&DuctileIronGrate
SupplyandinstallationofdrainagechannelforlineartypeTechnodrainMagnum
City,madefromHDPE(HighDensityPolyethylene)resistanttosaltandacids
solution. Structure by external stiffening rib to the body channel. Applicable flat
baseforeasyinstallation.Systemofmale-femalecouplingbetweenchannelsthat
allowtheassemblygratesandcoversthepreviouslyestablishedchannel.7mm
HDPEedgefortheinclusionofembeddedgratesisatleast40mm.Locations
outside the channel for the insertion of steel rods diameter 8 to 12mm for a
better anchorage to the concrete. Preformed outlet on the bottom with a diameter
upto250mm.
Dimensions (mm):Length500mm,ClearOpeningWidth302mm,InternalDepth
320mm.
ProductCode: 81391
Product Description: TechnodrainMagnumCity300HDPEChannel&DuctileIron
Grate(ClassD)WithoutOutletx500mm.
Weight: 23kg
ProductCode:81390
Product Description: TechnodrainMagnumCity300HDPEChannel&DuctileIron
Grate(ClassD)WithOutletx500mm
Weight: 23kg
DIMENSIONS
L
390
H
410
LN
302
Hi
320
DIAMETER Ø200
OUTLET
Ø250
All dimensions are in mm.
National Customer Service Number:
13 1926
www.everhard.com.au