Installation and Operation Manual TANDOOR OVENS Commerical European Models

Transcription

Installation and Operation Manual TANDOOR OVENS Commerical European Models
Installation and
Operation Manual
TANDOOR OVENS
Commerical European Models
Round, Square, Octagonal and Barrel Models
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
TANDOOR 31" AND 35"
WS-GFT-31
WS-GFT-35
WS-GFT-CUS
woodstone-corp.com
t.+1.360.650.1111
f.+1.360.650.1166
Revised January 2014
Doc no: M0054.00
TABLE OF CONTENTS
Tandoor Installation and Operation Manual
TABLE OF CONTENTS
TANDOOR���������������������������������������������������3
CAUTIONS AND WARNINGS �������������������������4
GFT-31 SPECIFICATIONS �����������������������������5
GFT-35 SPECIFICATIONS �����������������������������6
CLEARANCES & VENTING�����������������������������7
GAS SPECIFICATIONS�����������������������������������8
OPERATION�������������������������������������������������9
LIMITED WARRANTY ���������������������������������11
An ongoing program of product improvement may require us to change
specifications without notice. WS-GFT-CE, Revised January 2014
2
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
t.+1.360.650.1111
f.+1.360.650.1166
[email protected] or visit woodstone-corp.com
TANDOOR
TANDOOR
Tandoor Installation and Operation Manual
INSTALLATION AND OPERATION MANUAL FOR THE
WOOD STONE TANDOOR
GAS-FIRED TANDOOR OVEN
WS-GFT-31 (ROUND, SQUARE AND OCTAGONAL),
WS-GFT-35 (ROUND, SQUARE, OCTAGONAL)
CE MODELS
ADDITIONAL COPIES AVAILABLE UPON REQUEST
Square model (shown with
optional utensil rails, pan rail
w/ pans and shelf)
Octagonal model
An ongoing program of product improvement may require us to change
specifications without notice. WS-GFT-CE, Revised January 2014
Barrel model
Round model
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
t.+1.360.650.1111
f.+1.360.650.1166
[email protected] or visit woodstone-corp.com
3
CAUTIONS AND WARNINGS
Tandoor Installation and Operation Manual
INSTALLATION AND OPERATING INSTRUCTIONS FOR THE WOOD STONE
GFT-31-(RND, SQR, OCT)-(NG, LP), GFT-35-(RND, SQR, OCT)-(NG, LP)
TANDOOR OVENS
RETAIN THIS MANUAL FOR FUTURE REFERENCE
Additional copies of this manual at woodstone-corp.com.
For prompt responses to service/maintenance questions, call your local distributor.
READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS APPLIANCE
Please read this entire manual before you install the oven. Failure to follow instructions may result in
property damage, bodily injury or even death. Contact your local building or fire officials about restrictions
and installation inspection in your area.
It is recommended that this oven be installed, maintained and
serviced by authorized professionals.
IMPORTANT: Consult your local gas supplier for a statement outlining a procedure to be followed in the event you
smell gas. Post the statement in a prominent location.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this
or any other appliance. Also, always keep the area under and around this appliance free and clear of any
and all combustible materials.
WARNING: Improper installation, adjustment, alteration, service or maintenance can result in property
damage, injury or death. Read the installation, operation and maintenance instructions thoroughly before
installing or servicing this equipment.
DO NOT THROW THIS MANUAL AWAY
Wood Stone's gas-fired Tandoor was tested and approved by Intertek Testing Services,
to the requirements of BS-EN 203-1:2005
and BS EN 203-2-1:2005 for Safety of Catering Equipment.
An ongoing program of product improvement may require us to change
specifications without notice. WS-GFT-CE, Revised January 2014
4
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
t.+1.360.650.1111
f.+1.360.650.1166
[email protected] or visit woodstone-corp.com
G
G
G
GFT-31 SPECIFICATIONS
Tandoor Installation and Operation Manual
O 12"
300mm
O 12"
300mm
O 12"
300mm
Opening
Opening
Opening
WS-GFT-31 (ROUND, OCTAGONAL AND SQUARE MODELS)
Plan view (Round)
30 3/4"
Front view (Round)
30 3/4"
780mm
780mm
G
G
G
G
G
Air intake: Do not
facade or cover over
30 3/4"
780mm
30 3/4"
780mm
30 3/4"
780mm
21"
530mm
30 3/4"
780mm
Shipping weight:
431 Kg
(750 lbs.)
G
37 3/4"
960mm
21 1/2"
550mm
31"
790mm
O 12"
300mm
Opening 12"
O 300mm
Opening
Side view (Round)
21"
530mm
30 3/4"
780mm
30 3/4"
780mm
21"
530mm
G
G
Note: Side and front
G
PART #: WS-GFT-31-RND
view dimensions
DATE: 10/14/2013
are the same for
37 3/4"
960mm
21 1/2"
550mm
Bellingham, WA 360/650-1111 www.woodstone-corp.com
37 3/4"
960mm
DIMENSIONS ARE IN INCHES
TOLERANCES: LINEAR ±1/2 [±10mm], ANGULAR ±2°
UNLESS NOTED OTHERWISE
31"
790mm
31"
790mm
12 3/4"
AN ONGOING PROGRAM OF PRODUCT
320mm IMPROVEMENT
6MAY
1/4"12" REQUIRE US TO CHANGE SPECIFICATIONS
O
300mm
160mm
Opening
WITHOUT NOTICE.
6 1/4"
O 12"
300mm
Opening
21 1/2"
550mm
SHEET: 1 of 1
the DWN BY: bena
Round, Square and
31" Tandoor. All Shape
Octagonal models.
General Arrangement
LEGEND:
160mm
Plan view (Octagonal)
30 3/4"
780mm
/4"
mm
12 3/4"
320mm
Opening 12"
O 300mm
Opening
Plan view (Square)
0 3/4"
80mm
12 3/4"
320mm
6 1/4"
160mm
O 12"
300mm
O 12"
300mm
Opening 12"
O 300mm
Opening
THE INFORMATION CONTAINED IN THIS DRAWING IS THE
SOLE PROPERTY OF WOOD STONE CORPORATION
ANY REPRODUCTION OR USE IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS
UTILITY SPECIFICATIONS
PROHIBITED
GAS INLET: 1/2" NPT
G 40,000 BTU, NG
40,000 BTU, LP
Gas: 19mm (3/4") BPT gas inlet (female threaded)
See gas ratings in the GAS SPECIFICATIONS section of this manual. Gas
type must be specified when ordering.
Gas connection should SHEET:
be made
an approvedREV:
flexible connector
1 of using
1
PART #: WS-GFT-31-RND
and
the
unit
must
be
restrained
in
accordance
with
all
relevant
REV: local and
1 of 1
DATE:
PART
#: WS-GFT-31-RND
10/14/2013
DWNSHEET:
BY: bena
21 1/2"
national
550mm codes. Gas connection is made beneath unit at rear.
DATE: 10/14/2013
DWN BY: bena
Venting
31" Tandoor. All Shapes
This appliance
be installed
an exhaust hood, in accordance
31" must
Tandoor.
Allunder
Shapes
General
Arrangement
with all relevant local and national codes, and in a manner acceptable to
Arrangement
the authorityGeneral
having jurisdiction.
21"
530mm
\\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-31_General_Arrangement-1.dft
G
G
Bellingham, WA 360/650-1111 www.woodstone-corp.com
Bellingham,DIMENSIONS
WA 360/650-1111
www.woodstone-corp.com
ARE IN INCHES
1
TOLERANCES: LINEAR ±1/2 [±10mm], ANGULAR ±2°
DIMENSIONS
ARE IN INCHES 12 3/4"
UNLESS
NOTED OTHERWISE
320mm ±2°
TOLERANCES:
LINEAR ±1/2 [±10mm], ANGULAR
O 12"
300mm
AN ONGOING PROGRAM
OF
PRODUCT
IMPROVEMENT
UNLESS
6 1/4"NOTED OTHERWISE
Opening
MAY REQUIRE US TO
CHANGE SPECIFICATIONS
160mm
AN ONGOINGWITHOUT
PROGRAMNOTICE.
OF PRODUCT IMPROVEMENT
LEGEND:
MAY REQUIRE US TO CHANGE SPECIFICATIONS
LEGEND:
THE INFORMATION CONTAINED
IN NOTICE.
THIS DRAWING IS THE
WITHOUT
SOLE PROPERTY OF WOOD STONE CORPORATION
THE
INFORMATION
CONTAINED
IN
THIS
DRAWING
IS
THE
ANY REPRODUCTION OR USE IN PART OR AS A WHOLE
SOLE
OF WOOD STONE
CORPORATION
WITHOUT
THEPROPERTY
WRITTEN PERMISSION
OF WOOD
STONE IS
ANY REPRODUCTION
OR USE IN PART OR AS A WHOLE
21" PROHIBITED
530mm
WITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS
PROHIBITED
GAS INLET: 1/2" NPT
G 40,000 BTU, NG
GAS INLET:
1/2" NPT
40,000 BTU,
LP
G 40,000 BTU, NGwood stone corporation
An ongoing
of product improvement may require us to change
\\woodstone.net\dfs\CAD\0
Pn\WS program
Top Level\WS-GFT-31_General_Arrangement-1.dft
oodstone-corp.com
1801 w. bakerview rd.
bellingham, wa 98226 usa
40,000 BTU, LP
\\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-31_General_Arrangement-1.dft
t.+1.360.650.1111
f.+1.360.650.1166
[email protected] or visit woodstone-corp.com
specifications without notice. WS-GFT-CE, Revised January 2014
PART #: WS-GFT-31-RND
21 1/2"
550mm
DATE: 10/14/2013
1
SHEET: 1 of 1
DWN BY: bena
REV:
1
5
G
G
G
GFT-35 SPECIFICATIONS
Tandoor Installation and Operation Manual
O 13"
330mm
O 13"
330mm
Opening
Opening
O 13"
330mm
Opening
WS-GFT-35 (ROUND, OCTAGONAL AND SQUARE MODELS)
34 3/4"
Plan view (Round)
880mm
Front view (Round)
34 3/4"
880mm
34 3/4"
880mm
34 3/4"
880mm
24 3/4"
630mm
34 3/4"
880mm
Air intake: Do not
facade or cover over
34 3/4"
880mm
G
G
G
G
G
Shipping weight:
431 kg
(950 lbs.)
G
40 3/4"
1040mm
24 1
620m
33 3/4"
860mm
Opening
O 13"
330mm
Opening
Opening
O 13"
330mm
Opening
O 13"
330mm
Opening
O 13"
330mm
Opening
Plan view (Square)
34 3/4"
880mm
34 3/4"
880mm
24 3/4"
630mm
24 3/4"
630mm
G
40 3/4"
1040mm
40 3/4"
1040mm
33 3/4"
860mm
33 3/4"
860mm
Bellingham, WA 360/650-1111 www.woodstone-corp.com
24 1/2"
620mm
AN ONGOING PROGRAM OF PRODUCT IMPROVEMENT
MAY REQUIRE
US TO CHANGE SPECIFICATIONS
6 1/4"
160mm
WITHOUT NOTICE.
LEGEND:
THE
CONTAINED IN THIS DRAWING IS THE
SOLE PROPERTY OF WOOD STONE CORPORATION
ANY REPRODUCTION OR USE IN PART OR AS A WHOLE
24 3/4" THE WRITTEN PERMISSION OF WOOD STONE IS
WITHOUT
UTILITY SPECIFICATIONS
630mm
PROHIBITED
34 3/4"
880mm
GAS INLET: 1/2" NPT
G 40,000 BTU, NG
40,000 BTU, LP
Gas: 19mm (3/4") BPT gas inlet (female threaded)
See gas ratings in the GAS SPECIFICATIONS section of this manual. Gas
type must be specified when ordering.
REV:connector
Gas connection should be made
using
1 of 1an approved flexible
PART #: WS-GFT-35-RND
SHEET:
REV: local and
24 1/2"
1
of 1
PART
#: WS-GFT-35-RND
SHEET:
and
the
unit
must
be
restrained
in
accordance
with
all
relevant
DATE:
10/14/2013
620mm
DWN BY: bena
DATE: 10/14/2013
national codes. Gas connection
made
benabeneath unit at rear.
DWNisBY:
Venting 35" Tandoor. All Shapes
35" must
Tandoor.
Allunder
Shapes
This appliance
be installed
an exhaust hood, in accordance
General
Arrangement
with all relevant
local andArrangement
national codes, and in a manner acceptable to
General
the
authority
having
jurisdiction.
LEGEND:
\\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-35_General_Arrangement-1.dft
G
Bellingham, WA 360/650-1111 www.woodstone-corp.com
Bellingham, WA 360/650-1111 www.woodstone-corp.com
11
DIMENSIONS ARE IN INCHES
TOLERANCES:
LINEAR ARE
±1/2 IN
[±10mm],
±2°
DIMENSIONS
INCHESANGULAR
14 1/4"
UNLESS
NOTED
OTHERWISE
360mm ±2°
TOLERANCES:
LINEAR
±1/2 [±10mm],
ANGULAR
O 13"
330mm
UNLESS
NOTED
OTHERWISE
Opening
AN ONGOING
PROGRAM
PRODUCT IMPROVEMENT
6 1/4" OF
160mm
MAY REQUIRE
US
TOOF
CHANGE
SPECIFICATIONS
AN ONGOING
PROGRAM
PRODUCT
IMPROVEMENT
WITHOUT
NOTICE.
MAY REQUIRE US
TO CHANGE
SPECIFICATIONS
LEGEND:
NOTICE.
THE INFORMATIONWITHOUT
CONTAINED
IN THIS DRAWING IS THE
SOLE
PROPERTY
OF
WOOD
STONE
CORPORATION
THE INFORMATION CONTAINED IN THIS DRAWING IS THE
ANY
REPRODUCTION
OR USESTONE
IN PART
OR AS A WHOLE
SOLE
PROPERTY OF WOOD
CORPORATION
WITHOUT
THE WRITTEN
STONE IS
24 3/4" ORPERMISSION
ANY REPRODUCTION
USE IN PART OF
ORWOOD
AS A WHOLE
630mm PROHIBITED
WITHOUT THE WRITTEN
PERMISSION OF WOOD STONE IS
PROHIBITED
GAS INLET: 1/2" NPT
GGAS40,000
INLET:BTU,
1/2" NG
NPT
40,000
BTU,
G 40,000
BTU,
NG LP
wood stone corporation
40,000 BTU, LP
\\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-35_General_Arrangement-1.dft
\\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-35_General_Arrangement-1.dft
An ongoing program of product improvement may require us to change
specifications without WS-GFT-35-RND
notice. WS-GFT-CE, Revised January 2014
PART #:
DATE: 10/14/2013
SHEET: 1 of 1
DWN BY: bena
24 1/2"
620mm
35" Tandoor. All Shapes
1801 w. bakerview rd.
bellingham, wa 98226 usa
t.+1.360.650.1111
f.+1.360.650.1166
[email protected]
or visit woodstone-corp.com
REV:
1
DWN BY: bena
35" Tandoor. All Shape
6 1/4"
160mm
INFORMATION
Plan view (Octagonal)
SHEET: 1 of 1
General Arrangement
Opening
Opening
CHES
Note: Side and front
view dimensions
are the same for the
PART #: WS-GFT-35-RND
Round, Square and
DATE: 10/14/2013
24 1/2"
620mm Octagonal models.
DIMENSIONS ARE IN INCHES
TOLERANCES: LINEAR ±1/214[±10mm],
ANGULAR ±2°
1/4"
13"
O 330mm
UNLESS NOTED 360mm
OTHERWISE
O 13"
330mm
6
ne-corp.com
6 1/4"
160mm
14 1/4"
360mm
Side view (Round)
G
G
G
14 1/4"
360mm
O 13"
330mm
O 13"
330mm
INSTALLATION
CLEARANCES & VENTING
Tandoor Installation and Operation Manual
!
WARNING: Do not pack required air space (clearance) with insulation or other materials.
When non-combustible building materials contact the body of the oven, the clearances to
combustibles are transferred to those non-combustibles.
INSTALLATION CLEARANCES
The Wood Stone gas-fired Tandoor must be installed with at
least 25mm (1") side clearance to combustible construction.
Install the unit on a non-combustible floor, or one provided with
a non-combustible covering that extends at least 92mm (36") in
all directions. Any combustible construction above (overhanging)
the appliance should be protected in a manner acceptable to the
authority having jurisdiction.
Combustible construction overhanging
the appliance should be protected in
a manner acceptable to the authority
having jurisdiction.
ENCLOSURES
If the appliance is enclosed, provisions should be made so that it
can easily be removed from the enclosure.
25mm (1") side
clearance to
combustible
construction
Shaded area must be left unobstructed for
critical combustion air and easily accessible
for removal of the drip pan and operation
of the pilot safety valve. If this area must
be covered, the cover should be easily
removable and heavily perforated.
Install on a noncombustible floor, or one
protected in a manner acceptable to the
authority having jurisdiction, extending
92mm (36") in all directions.
VENTING
The Wood Stone gas-fired Tandoor must be installed under an appropriate grease rated exhaust hood. Refer to local and/
or national codes for hood specification requirements. The hood must be designed for the removal of the combustion
products of gas, as well as the cooking vapors related to the intended use of the oven. Make up air must be provided as
necessary for the proper operation of the ventilation system.
Some jurisdictions may require that the Tandoor be interlocked to the hood ventilation system to prevent operation of the
appliance when the ventilation system is not turned on. If an interlock is required, use an approved gas solenoid (supplied
and installed by others), wired so that the gas supply to the appliance is turned off whenever the ventilation system is
turned off.
An ongoing program of product improvement may require us to change
specifications without notice. WS-GFT-CE, Revised January 2014
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
t.+1.360.650.1111
f.+1.360.650.1166
[email protected] or visit woodstone-corp.com
7
GAS SPECIFICATIONS
Tandoor Installation and Operation Manual
GAS CONNECTION
The gas connection is made at the lower rear of the appliance. See next page for details.
This appliance is equipped with casters; it must be installed using the casters supplied with an approved gas connector/
quick disconnect device in accordance with all pertinent national and local regulations. It must also be installed with
restraining means to guard against transmission of strain to the connector.
IMPORTANT: The gas supply to this appliance should be equipped with an individual appliance shutoff valve that is
capable of completely isolating the appliance from the main gas supply. This valve should be installed in such a manner
as to be readily accessible to the operator of the appliance.
The Wood Stone gas-fired Tandoor is equipped with a 19mm (3/4") BPT female gas connection, located on the underside
of the rear of the unit. Anchor points for the restraining means are provided on the underside of the Tandoor; these are
holes punched in the rear portion of the drip/debris pan rails.
GAS RATINGS
Model
Input (kW)
Gas Group
Inlet Pressure (mbar)
Gas Pressure at Valve
Outlet (mbar)
WS-GFT-31 and WS-GFT-35
11.7
I2H
20
11.7
I2L
25
11.7
I2E
20
14.2
I3+
28-30/37
11.7
I3P
30/37/50
14.2
I3B/P
28-30/37
14.2
I3B/P
50
10
10
10
25
25
25
25
THIS APPLIANCE IS NOT FOR USE WITH SOLID FUEL
GAS CODE LIMITATIONS
The installation of this appliance must conform with local codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1, the Natural Gas installation Code CAN/CGA-B149.1 or the Propane Installation Code, CAN/
CGA-B149.2, as applicable.
The appliance and its individual shutoff valve (supplied by others) must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve (supplied
by others) during any pressure testing of the gas supply piping system at test pressure, equal to or less than 1/2 psi
(3.45 kPa).
An ongoing program of product improvement may require us to change
specifications without notice. WS-GFT-CE, Revised January 2014
8
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
t.+1.360.650.1111
f.+1.360.650.1166
[email protected] or visit woodstone-corp.com
OPERATION
OPERATION
Tandoor Installation and Operation Manual
PILOT LIGHTING PROCEDURE
Turn the Temperature Control Knob on the top of the unit to the OFF posiiton before attempting to light the pilot.
1. Turn the Gas Control Knob on the safety valve to the PILOT position.
2. Push down on the Gas Control Knob and light the pilot immediately by pressing the red button of the
spark igniter. Press the igniter every 2 seconds until a pilot flame is established. Hold the Gas Control Knob down
for one full minute after lighting the pilot.
3. Release the Gas Control Knob – the pilot flame should continue to burn. If the pilot flame does not remain lit,
turn the gas control valve to the OFF position, wait 5 minutes, and then repeat the steps above.
4. Once pilot is established, turn the Gas Control Knob on the safety valve (counterclockwise) from the PILOT
to the ON position. NOTE: failing to turn the gas control knob to the full ON position will reduce the flow of gas
and could result in poor ignition of the main burner.
5. Use the Temperature Control Knob on top of the Tandoor to control the height of the cooking flame. For
Barrel models, temperature control is located on the control box at the front end of the oven.
Lid
Plan view
Front view
Temperature
Control Knob
Drip/ debris pan
Gas Control Knob
FIRST FIRING
The first time the Tandoor is fired, the heat-up should be slow and steady. Hold the burner
at a very low flame (Temperature Control Knob set at “1” on models that are marked) for
at least 8 hours with the lid on. Following this procedure will safely saturate the chamber
with heat. You may notice some small "crazing" cracks in the ceramic chamber after a
few heat-ups and cool-downs. Don't be alarmed as this is normal and will not affect the
longevity or performance of the Tandoor.
Spark Igniter Button (Red)
Temperature Control Knob
First firing setting
An ongoing program of product improvement may require us to change
specifications without notice. WS-GFT-CE, Revised January 2014
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
t.+1.360.650.1111
f.+1.360.650.1166
[email protected] or visit woodstone-corp.com
9
OPERATION
Tandoor Installation and Operation Manual
DAILY OPERATION
At the start of the day, the Tandoor will need to be heated for approximately 60–90 minutes
at full flame height (5) with the lid on.
Temperature
Control Knob
Once the chamber is at the desired temperature, typically 620 °F–650 °F, remove the lid
completely for the cooking day. (The Tandoor will overheat if the lid is left on after heat-up.)
Temperature can be determined using the optional Fluke Hand Held IR Thermometer (see
the Tools and Accessories section of the Wood Stone website).
Set the Temperature Control Knob to “1.3–1.5”. This should maintain a good cooking
temperature for breads and proteins. The Temperature Control Knob will be used to adjust
the heat, depending on cooking style. Note that settings may vary slightly depending on
gas type (NG or LP).
The use of ceramic briquettes, or seasoning the chamber, is unnecessary and
will void the warranty.
To avoid damage to the top of the Tandoor, do not operate the unit with the
lid on except during heat-up. Heat damage caused by operating the Tandoor
with the lid on will not be covered by the warranty.
Heat-up setting
Typical cooking
flame setting
CLEANING
Debris that falls in the Tandoor will accumulate in the bottom of the chamber. Push the debris towards the center and
under the circular flame deflector, using the supplied Tandoor Naan Hook, where it will fall into the drip pan under the
unit. This pan should be checked daily and emptied as necessary.
To remove debris from the chamber walls, first brush the walls with the optional In-Line Floor Brush (see the Tools and
Accessories section of the Wood Stone website). Use a moist towel (water only) to swirl around the chamber. Any debris
which falls to the bottom of the chamber can be removed as described above.
The stainless cabinet and granite top of the unit should be cleaned as necessary, using a mild detergent and a nonabrasive
scouring pad.
TIP: Watch Wood Stone’s Tandoor-related videos for additional helpful information. Visit the Resource Center/Videos
section of the Wood Stone website.
NOTE: TO PREVENT DAMAGE TO THE TOP OF THE TANDOOR, DO NOT OPERATE THE TANDOOR WITH THE LID ON
EXCEPT DURING HEAT-UP. SOME DISCOLORATION OF THE STONE MAY OCCUR IF THE LID IS OFF WHILE THE UNIT
IS RUNNING. THIS NORMAL DISCOLORATION IS ONLY COSMETIC AND DOES NOT HARM THE UNIT.
An ongoing program of product improvement may require us to change
specifications without notice. WS-GFT-CE, Revised January 2014
10
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
t.+1.360.650.1111
f.+1.360.650.1166
[email protected] or visit woodstone-corp.com
LIMITED WARRANTY
LIMITED WARRANTY
Tandoor Installation and Operation Manual
CONTACT YOUR LOCAL DISTRIBUTOR FOR WARRANTY SERVICE
Wood Stone warrants its equipment to the original purchaser against defects in material or manufacture for a period of
one year from the original date of purchase, subject to the following exclusions and limitations.
EXCLUSIONS
The warranties provided by Wood Stone do not apply in the following instances:
1. In the event that the equipment is improperly installed. Proper installation is the responsibility of the installer; proper installation
procedures are prescribed by the Wood Stone Installation and Operation Manual.
2. In the event the equipment is improperly or inadequately maintained. Proper maintenance is the responsibility of the user;
proper maintenance procedures are prescribed in the Wood Stone Installation and Operation Manual. Burner problems resulting
from debris or ash in the burner well will not be covered by the warranty. Call with questions regarding maintenance frequency.
3. In the event that the failure or malfunction of the appliance or any part thereof is caused by abnormal or improper use or is otherwise
not attributable to defect in material or manufacture.
4. In the event that the appliance, by whatever cause, has been materially altered from the condition in which it left the factory.
5. In the event that the rating plate has been removed, altered or obliterated.
6. On parts that would be normally worn or replaced under normal conditions.
7. Normal cracking due to expansion and contraction stress relief in the ceramic firebox.
8. In wood-fired equipment configurations, in the event that pressed log products of any type have been burned in the equipment.
9. In coal-fired oven configurations, in the event any type of coal other than anthracite coal fuel has been used.
10.Damage resulting from the use of chemical cleaning products in the oven, as well as any damage from liquids or chemicals, including
water, being poured or sprayed into the oven.
If any oral statements have been made regarding this appliance, such statements do not constitute warranties and are not part of the
contract of sale. This Limited Warranty constitutes the complete, final and exclusive statement with regard to warranties.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN, ORAL OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE OR WARRANTY AGAINST LATENT DEFECTS.
LIMITATIONS OF LIABILITY
In the event of warranty claim or otherwise, the sole obligation of Wood Stone shall be the repair and/or replacement, at the option of
Wood Stone, of the appliance or component or part thereof. Such repair or replacement shall be at the expense of Wood Stone with the
exception of travel over 100 miles or two hours, overtime, and holiday charges which shall be at the expense of the purchaser. Any repair
or replacement under this warranty does not constitute an extension of the original warranty for any period of the appliance or for any
component or part thereof. Parts to be replaced under this warranty will be repaired or replaced at the option of Wood Stone with new
or functionally operative parts. The liability of Wood Stone on any claim of any kind, including claims based on warranty, expressed or
implied, contract, negligence, strict liability or any other theories shall be solely and exclusively the repair or replacement of the product
as stated herein, and such liability shall not include, and purchaser specifically renounces any rights to recover, special, incidental,
consequential or other damages of any kind whatsoever, including, but not limited to, injuries to persons or damage to property, loss of
profits or anticipated profits, or loss of use of the product.
TO SECURE WARRANTY SERVICE
If you claim a defect covered by this Limited Warranty, contact your local distributor:
An ongoing program of product improvement may require us to change
specifications without notice. WS-GFT-CE, Revised January 2014
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
t.+1.360.650.1111
f.+1.360.650.1166
[email protected] or visit woodstone-corp.com
11