GENERATOR & POWER STATION PROTECTION
Transcription
GENERATOR & POWER STATION PROTECTION
A 2-Day Professional Development Seminar on GENERATOR & POWER STATION PROTECTION SYDNEY 17-18 November 2014 Mercure Sydney Who Should Attend Technical personnel who are involved in planning, design, installation, operation and maintenance of protection system for generators and power stations, such as PERTH 27-28 November 2014 Mercure Perth Protection Design Engineers ◊ Planning Engineers ◊ Operation & Maintenance Engineers ◊ Circuitry Design Engineers Commissioning & Project Management Engineers ◊ Technicians ◊ ◊ 9.00 am - 5.00pm Organised By : CPD INTERNATIONAL PTY LTD Your True Partner in Attaining Professional Excellence Introduction The requirements of safety, minimisation of damage to faulted plant, minimisation of consequential damage to healthy plant and maintenance of a stable and secure supply of electricity are paramount to all protection designs. A generator may be exposed to three types of occurrence which require protection schemes to operate effectively and efficiently but in vastly different time frames. ◊ Generator Fault : This requires instantaneous tripping of the generator to minimise the damage caused. Generator multiphase fault levels may exceed 100kA, whereas, via high resistance earthing techniques, the same generator may have an earth fault level of only a few amperes. ◊ Generator Event : This is an event local to the generator which will not immediately cause damage but will eventually do so unless rectified. Protection initiates an alarm rapidly to alert the operator and to allow intervention and, if this is unsuccessful, finally tripping before actual generator damage occurs. Course Content 1. High Impedance Differential Protection - Application to Generators, Transformers and Busbars ● ● Determination of setting voltage ● Determination of scheme primary operating current ● In this seminar we will consider the application of protection to generators, considering the three occurrences mentioned above. This will facilitate an appreciation of generator protection, the coordination aspects of these protection schemes, and the information required to determine protection settings. Application of series ● ● shunt MOVs) CT supervision requirements Application of high impedance differential protection principles to plant other than busbars ● Introduction to Buchholz and Pressure Relief Devices (PRDs) ● Introduction to Positive, Negative and Zero Sequence Component Analysis, in particular: ● Transformer Earth faults, sequence components and transformer phase shifts ● Transformer Phase-Phase faults, sequence components and transformer phase shifts ● Biased differential protection ● Inrush and magnetising currents ● Over-excitation (excessive V/Hz) currents ● CT connections for phase correction ● CT connections for zero compensation ● CT ratio selection ● Phase angle, zero sequence and CT ratio compensation via microprocessor based relay Thus the task, not only for the protection engineer, but for all engineers and technicians associated with the power station, is to ensure that planning, design, coordination, implementation, commissioning, operation and maintenance of protection systems optimises both the dependability and security of these schemes. applications ● Restricted Earth What You Will Learn? ● Delegates will learn the principles of power station protection schemes, the art of scheme selection, and the generic processes associated with determination of optimal settings and configurations for the protection relays and schemes associated with power station generators, motors, busbars and transformers. and 2. Transformer Protection But, beyond the generator itself, the power station engineers and technicians need an intimate understanding of the protection schemes associated with the remaining plant, including busbars, transformers and the many large induction motors. This 2-day seminar focuses on the principles of generator and power station protection schemes, including their application to generator faults, generator events, external power system events, and power station motor, busbar and transformer faults. (stabilising) (de-sensitising) resistors ● Application of non-linear resistors (Metrosils and ◊ External Event : This is a transmission system event which will not immediately cause damage to the generator and can be rectified by operator intervention. An alarm is generated rapidly to alert the operator of the condition, followed by tripping as necessary if appropriate action is not taken or is not successful. In particular, note that such events affect every generator within a particular power station, and even may affect generators over a wide area. Hence tripping must be delayed as long as possible to avoid widespread system shut-downs, but must nevertheless still provide protection for the affected generating plant. High impedance differential protection principles Fault sequence (REF) current protection of transformers Transformer delta connected windings and the application of earthing transformers ● Earthing Transformer OC & EF protection ● Effect on the overall transformer differential protection scheme ● Zero sequence current consequences and compensation techniques About the Course Leader Barrie Moor B.E (Elec),RPEQ 3. Motor Protection ● Starting Current, Stalling Current, High Inertia Loads and Thermal Capability ● Number of Starts Limitation ● Effects of Unbalanced (Negative Phase Sequence) Events ● Earth Fault Protection – High impedance and core balance schemes ● ● RTD Protection Undervoltage Protection ● Loss of Load Protection ● Over Current Protection – via CBs, fuses and fuse contactors ● Differential Protection 4. Generator Protection ● Biased Differential and High Impedance Differential ● Protection Schemes Voltage Displacement Protection ● Stator Earth Fault Protection (100%, 95%, REF and 3rd harmonic schemes) ● Stator Interturn Protection ● Rotor Earth Fault Protection ● GCB Fail Protection ● Stator Overload Protection ● Negative Phase Sequence (NPS) Protection ● Over Voltage and Over Excitation Protection ● Under Excitation Protection ● Reverse Power Protection ● ● Under and Over Frequency Protection Out of Step Protection ● Embedded Generator Islanding Protection CPD Recognition This training program is designed to meet the Continuing Professional Development (CPD) needs of participants. A Certificate of Attendance will be awarded at the end of the program. This serves as evidence of your personal and professional commitment to building your career. Barrie Moor is the Principal Engineer at Power System Protection Training, a provider of professional development training seminars on the topics of power system principles and power system protection. With over 39 years experience in the Queensland electricity transmission industry, Barrie Moor has been involved in the design, coordination and implementation of protection schemes associated with Queensland’s HV and EHV transmission systems since 1981. Barrie also has extensive experience with the protection of large generating plants. From 2000 to 2007, Barrie filled the role of Senior Engineer Protection Design, with statewide responsibility, leading Powerlink’s Protection Design Team. From 2007 to 2012, in the role of Principal Consultant Substation Protection, and then Principal Engineer-Investigations., Barrie provided specialist Protection Design and Fault Analysis services to support the Asset Management and Operational Groups within Powerlink. Barrie has 20 years experience within Australia and Internationally in the provision of university post graduate training on the design and implementation of HV and EHV Transmission Protection Systems. He has presented a number of papers on specialized aspects of protection design at conferences both within Australia and internationally. Barrie has also represented Powerlink on CIGRE committee APB5, Power System Protection and Automation and has served as a corresponding member of Cigre and IEE working groups on Protection Systems. Who Should Attend? This seminar will assist both those whose day to day work involves them in the application of protection design, coordination and relay setting, and also to those in less directly associated areas of generator and power station protection system design. This seminar has been prepared specifically to meet the requirements of: Protection Design Engineers, to identify protection implications and to ensure design, coordination and relay setting principles provide the necessary levels of speed, security, dependability and safety Planning Engineers, to identify the difficulties in providing protection for various power system configurations under review Maintenance Engineers, to ensure that system protection is not compromised as primary and/or secondary system plant is removed from service during maintenance Circuitry Design Engineers, to ensure that protective schemes are implemented in a manner to provide optimum performance Commissioning and Project Management Customised In-House Course Available This program can be customised to suit the specific needs of your organisation at significant savings details. Please contact us on (02) 8448 2078 or email: [email protected] for more details. Engineers, to ensure the actual field installation of the protection scheme and associated relay settings meets the design requirements Technicians, to understand the importance of their role in installing, testing and maintaining effective, reliable, dependable and secure protection systems HOW TO REGISTER? Step 1 - COMPLETE THIS FORM AND FAX TO : (02) 8068 0130 A Confirmation of Booking and a Tax Invoice will be sent to you (via email or fax) upon receipt of registration form. Step 2 - MAKE APPROPRIATE PAYMENT, AFTER RECEIPT OF INVOICE, BY : OR CREDIT CARD : □VISA □MASTER Name on Card : __________________________________________________ Card No. : __________________________________________________ Expiry Date : __________________________________________________ Signature : __________________________________________________ (please tick √ the relevant box to indicate your method of payment) □ CHEQUE attached - payable to CPD International Pty Ltd. Mail it together with the completed registration form to us. OR □ EFT (Electronic Funds Transfer) to Account Name BSB No Account No Bank Reference : : : : : CPD International Pty Ltd 182-222 1210 77176 Macquarie Bank Please quote our invoice no. Purchase Order No. : _________________________________ (if applicable) ENQUIRIES : VISIT : CALL (02) 8448 2078 or EMAIL [email protected] www.cpdint.com.au for more courses REGISTRATION FORM Please register the following delegates for the event - “Generator and Power Station Protection” Seminar (Please tick √ the relevant box to indicate your choice of dates and venue, and print clearly in black pen for proper fax transmission) □SYDNEY, 17-18 November 2014, Mercure Sydney □PERTH, 27-28 November 2014, Mercure Perth DELEGATES : 1) MR/MS : …………………….……………….…………………..…………….…...………………...... JOB TITLE : ……..……………..…………...…………………..…….……….. EMAIL : ……………………………….…………………………..……...…….....……. ……………….…. TEL : ………………….……………………………….…………..................... 2) MR/MS : ……………………………..…………….……………………………..............................… JOB TITLE : …………………..……………...….……………………….…….. EMAIL : ……………………………………………..…………………….…………………….....………… TEL : ……………….…………….....………………...……….…………..…... 3) MR/MS : …………………………………………………….…………………...……………………..… JOB TITLE : ………………..….……………………..……….……………….. EMAIL : ……………………………………………………………………….….............….…………….....TEL : ……………………...…………….…………………………….…...…... ORGANISATION NAME : ……………………...……………………………………………….………………………………………...……………..………………………...……….....… ADDRESS : …………………………………………..………….……………………...….. ……………… STATE : …………………..…….… POSTAL CODE... .……………..….…. CONTACT PERSON : MR/MS ……………………………….………………………………………........JOB TITLE : ……..…………………….....…….…..……………….…………. SECTION/DEPARTMENT : ………………………………………………………………….……………...TEL : …………………………………...………..……..……...…….…..…….. EMAIL : ………………………………………………………………………………………………….…..…FAX : ………………………………….….…………………………….……… COURSE FEES & DETAILS Course Registration Fee : Register before 10 October 2014 : AUD1,280.00 + AUD128.00(GST) = AUD1,408.00 per delegate. Register after 10 October 2014 : AUD1,380.00 + AUD138.00(GST) = AUD1,518.00 per delegate. Register 3 or more delegates at the same time for this course: AUD1,242.00 + AUD124.20 (GST) = AUD1,366.20 per delegate Payment Terms : Payment is required before the event. Delegates may be refused admission if payment is not received prior to the event. Registration Fee includes lunch, refreshments and training documentation/notes. Cancellation : A substitute or replacement is welcome at no additional charge. However, any cancellation of registration must be made in writing. If you cancel at 14 or more calendar days before the commencement of the event, you will receive a full refund, minus a nonrefundable $250 administration fee. If you have not paid for the event, you will still be invoiced for the $250 administration fee. If you cancel within 14 calendar days of the commencement of the event, you will be charged the full fee, even if you have not paid yet. Accommodation : Arrangements for accommodation are the responsibility of participants and costs are not included in the course fee. Accommodation is available at the venue/close by and information can be made available to interested participants. Note : The organizer reserves the right to make changes to the event schedule, contents and venue. The views expressed in the event are not necessarily those of CPD International Pty Ltd. ———————————————–—-——-—————–——————————-— ABN 49 108 072 162 ACN 108 072 162 Address : Level 20, Tower A, Zenith Centre 821 Pacific Highway Chatswood NSW 2067, Australia Tel : (02) 8448 2078 Fax: (02 ) 8068 0130 Your True Partner in Attaining Professional Excellence