Last updated: 20 Oct 2014
Transcription
Last updated: 20 Oct 2014
Last updated: 20 Oct 2014 VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES Foreword by the United Arab Emirates (UAE) Acting Commander in Chief, Major General Rashid Thani Al Matrooshi As the dynamic environment in our Region progresses, we the UAE Civil Defence Authority, has set forth a number of strategic goals for the delivery of public safety. Our strategic goals observe both the national and Ministry of Interior’s strategic plan by; “Providing an effective firefighting and emergency response system delivered by qualified and well trained people using the latest technologies to ensure lives and properties are safeguarded” As a result, the UAE can be ‘benchmarked’ with other Countries that are witnessing a decline in fires and incidents when compared to the density of population. As an example, the number of fire incidents has been reduced by 39% in 2011 compared to 2010, with a marked reduction in small and medium fire incidents, together with a high percentage achievement of a 9 minute response time for first attendance at incidents. “Providing excellent performance and support during disasters and crises” Confirmation of performance and support are achieved during disasters and crisis situations. Civil Defence Departments conduct a range of joint fire safety and evacuation drills in association with other safety agencies for both the public and private sectors. Evacuation drills carried out in Dubai during 2011 was estimated at 356 drills, which targeted 178,530 persons. Customer satisfaction percentage achieved was 97.2%. The number of drills carried out has increased by 142.4% compared to the target number set out in our annual plan. “Spreading a fire safety and awareness culture across the community “ In this regard, a National Safety campaign was launched targeting ‘domestic safety’ with an achieved target of 50% of homes in UAE being visited during a six month period. This was aimed at preventive awareness and removing violations which threaten public safety. During the campaign, 206,490 houses (61.4% of the total dwellings) were visited, again with a marked customer satisfaction percentage of 92%. Similarly a National Safety campaign was also executed at industrial areas, with teams visiting industrial facilities at different industrial areas across the country. 31,647 facilities were inspected. The teams also managed to correct violation situations in 13,400 facilities and 53,426 people were trained in the basic skills of firefighting and awareness. “Equipping operations with the best and appropriate equipment and technologies” The latest state of the art technologies have been introduced for various services such as, ‘e-engineering’ for online drawing approval and the ’24 x 7 smart system’ for building electronic monitoring and protection. Currently 61.7% of buildings are connected to the system and 95.7% surveyed for connection. In addition, the ‘UAE Fire and Life Safety Code of Practice’ with our Standard Operating Procedures (SOPs) is considered a first in the region. This will contribute to reduced costs and effort. Ultimately this will result in a decrease in accidents and improve command and control mechanisms. “Achieving Strategic Partnership with Public/Private and Voluntary Organizations” By ensuring, through careful selection, that products, systems and installers are approved with a listing by Civil Defence, following rigorous third party certification. This ensures that locally we receive the best performance of fire safety products, systems and technologies. ii 20 Oct 2014 VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES LPCB is widely recognised as an independent reference for all fire and security safety experts. Their testing laboratories and approvals services together with their leading team of highly qualified expert scientists and engineers, guides us all impeccably towards a qualified framework. Major General Rashid Thani Al Matrooshi Introduction Welcome to the 2014 Edition of the “LPCB Red Book”, the list of approved products and services from LPCB. LPCB is the fire and security approval brand of BRE Global Ltd. which is part of the BRE Group operating under the BRE Trust. It is an independent third party approvals body offering certification of fire and security products and services to an international market. The LPCB mark and listings signify that products and services have been approved by LPCB. The Red Book is an essential reference for specifiers, regulators, designers and end users of these products and services - if it is listed here, you know it has been checked out by people you can trust BRE Global also offers independent approval of construction products, management systems and in the area of sustainability though its BRE Global Certification and BREEAM brands. Where these have relevance to fire safety and security these are also listed in the Red Book (The details of these schemes are given in the relevant introductory sections.) BRE Global Ltd is also a Notified Body for the purpose of CE marking and European Technical Assessment in connection with the European Construction Product Regulation (CPR) and other European Directives; the Pressure Equipment Directive (PED), Marine Equipment Directive (MED) and Transportable Pressure Equipment Directive (TPED). BRE Global - protecting people, property and the planet. The Red Book is divided into sections which list related groups of products and services such as suppression, security and so on. Each section also summarises the technical basis for the approval of each product or service. The Red Book should always be used in conjunction with rules, regulations and design specifications required by the relevant Authority having jurisdiction. The 2014 edition of the Red Book comprises: 20 Oct 2014 iii VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES Volume 1: (This Volume) Fire detection and alarm products, systems, and cables Manual fire extinguishing equipment Automatic sprinkler, water spray and deluge systems Fixed fire fighting products and systems Related installers Volume 2: Passive fire protection products Security protection products Fire doors and shutters Smoke and fire ventilation systems Related installers Management Systems Construction products Listings are given in the name of the manufacturer or service provider, in alphabetical order. They can be downloaded free of charge from our website at www.redbooklive.com and also via an App that is available free from Apple iStore (for iPhone and iPad), from Google Play, (for Android phones and tablets) and Windows Store (for Windows 8 phones). Red Book updates Product and services approval details are amended regularly. To ensure that you are using the most up to date information please refer to www.redbooklive.com or download the App. What is Third Party Approval? A frequent concern of stakeholders is in knowing whether a product will perform in accordance with the stated specifications. These concerns can involve such product attributes as safety, health or environmental impacts, durability, compatibility, suitability for intended purposes or for stated conditions, and other similar considerations. These issues can all be addressed through product approvals. Third party approval (or certification) is a conformity assessment process, carried out by a body that is independent of both supplier and customer organisations. It provides confirmation that products and services have met and will continue to meet the requirements of specified standards and other normative documents. LPCB third party product approval schemes are quality assurance schemes and comprise initial type testing and technical evaluation, assessment and surveillance of the manufacturer’s quality system and production procedures, regular audit testing, labelling and listing. Similarly, LPCB schemes for suppliers of services (installers) are also quality assurance schemes comprising a technical assessment of an installer’s capability, assessment and surveillance of the installer’s quality system and production procedures, regular inspection of completed installations and listing. Benefits of Third Party Approval For specifiers, regulators, insurers, manufacturers and installers, the benefits of an LPCB approval are: For specifiers and regulators: iv 20 Oct 2014 VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES Risk reduction - specifying LPCB approved products and services demonstrates due-diligence and best endeavour and mitigates against possible accusations of negligence. Avoidance of costly mistakes - you can trust LPCB approved products and services to conform each and every time. Time - using Red Book Live to search for and assess products and services can save you time. For manufacturers and installers: Increased global sales - LPCB approval is recognised and specified widely throughout the world. In some territories LPCB approval is a mandatory requirement. Added value of the product or service - LPCB approved products and services are recognised as providing added value given their ability to conform each and every time. Reduced liability - LPCB approved products and services demonstrate due-diligence which can reduce liability for both you and your customers. What does LPCB Approval offer? LPCB offers approvals to existing British, European, International and LPCB’s own Loss Prevention Standards (LPSs). LPCB’s LPS approval schemes for both products and services are essentially level 5 schemes, as described in ISO/IEC Guide 67, with the added requirement to have a quality system certificated to ISO 9001. The technical requirements of LPCB schemes are given in Loss Prevention Standards (LPSs). These documents are drafted by LPCB technical experts in conjunction with appropriate external experts. They are then peer reviewed by representatives from trade bodies, regulators, insurers, specifiers, manufacturers and other suppliers. Finally these documents are approved for use by the BRE Global Governing Body; the Body that oversees all of the certification activities of BRE Global, including LPCB. Product schemes comprise: Initial type testing and evaluation of product, sampled by LPCB. Approval and surveillance of the manufacturer’s (or supplier’s) quality management system to ISO 9001 (if you have products in for testing at LPCB, it generally costs little or no more to achieve ISO 9001 certification). Assessment and surveillance of the manufacturer’s (or supplier’s) factory production control system (FPC). Periodic audit testing of the product from either the factory or marketplace. Labelling or marking as appropriate. Listing of the approved product (service) in the Red Book Installer schemes comprise: Technical assessment of the installation contractor’s capability. Approval and surveillance of the contractor’s quality management system to ISO 9001 or assessment against the requirements of the relevant Loss Prevention Standard where ISO 9001 is not appropriate. (If you have applied for LPCB assessment of your services, it generally costs little or no more to achieve ISO 9001 certification). Regular surveillance inspections of on-going installations. The issue of Certificates of Conformity to demonstrate compliance for each installation. Listing of the approved installer in the Red Book. The LPCB Mark - the Mark you can trust After approval of a product or service the manufacturer or service provider is allowed to place the LPCB certification mark, as shown below , on the product, packaging and literature etc. In September 2011 this image was updated. 20 Oct 2014 v VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES To this from (Discontinued for new approvals from 1 October 2011) A transition period of up to three years has been allowed for the change, so although we expect many of our clients’ product(s) will already be carrying the new version of the mark, the ‘old’ mark remains valid and you can still rely on the products carrying the old mark where their certificate was issued before 1 October 2011. Together with the mark you should always determine the product/service certificate number and check if a listing still valid by going to www.redbooklive.com. Where LPCB holds accreditation through the United Kingdom Accreditation Service (UKAS), the approved company is allowed to include the UKAS symbol (the Crown and Tick) alongside the LPCB mark for certain applications e.g. promotional literature or material and stationery, as shown below. (Full details of LPCB accreditation can be found on the UKAS website at www.ukas.com) Where for reasons of space or cost the use of the above full mark is not practical, then the following simplified mark may be applied directly to the product (for some schemes only). The LPCB scheme rules define how and where the marks can be used. The LPCB horseshoe is the mark you can trust and it is recognised in over 60 countries around the world by regulators, specifiers, designers and end users. For Fire and Security Products and Services Trust the LPCB Mark Other Listings from BRE Global vi 20 Oct 2014 VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES 20 Oct 2014 vii CONTENTS 1 Fire detection and alarm products, systems & cables 1 SECTION 2 Fire detection and alarm systems 3 SECTION 3 Control and indicating equipment 7 SECTION 3 LPS 1014 certified fire detection and alarm system firms 208 SECTION 4.1 Commercial detectors 219 SECTION 4.2 Domestic alarms - smoke, heat and carbon monoxide 381 SECTION 5 Manual call points 393 SECTION 6 Line units 424 SECTION 7 Alarm warning devices 447 SECTION 8 Fire resistant cables 538 SECTION 9 Alarm receiving centres 616 SECTION 10 Alarm transmission and fault monitoring equipment and signalling systems 618 SECTION 10.1 Alarm transmission and fault warning routing equipment 620 SECTION 10.2 Supervised premises transceivers (fire) - LPS 1277 Issue 2.2 621 SECTION 10.3 Supervised premises transceivers (fire) - LPS 1277 Issue 3 622 viii 20 Oct 2014 INDEX 2 2M KABLO SAN. ve TIC. A.S. 540 3 3E - Electrical Energy Efficiency FZE 541 A Aarhus Fire Protection Limited 208 ADI (ADEMCO) 8 ADI International 220 ADT Fire and Security 208, 209 Advanced Electronics Limited 9, 221, 393, 424, 448 Advantronic Systems S.L. 223, 394, 425, 449 AEI Cables Limited 541 AGNI Devices PVT Ltd 225 Agni Suraksha Electronics Services 382 Aguilera Electronica S.L 226 Ajax Chubb Varel B.V. 11 Alarm Supply Pte Ltd 227 Alberta Fire & Security Equipment Limited 209 Alpha Fire Services W.L.L. 547 AMPAC Europe Limited 12 AMPAC Technologies PTY Ltd 17, 227, 394, 425, 450 Apollo Fire Detectors Limited 229, 395, 426, 451 Application Solutions (Safety and Security) Ltd, East Sussex, United Kingdom 20 Argus Fire Protection Company Limited 209 Argus Security S.r.l. 239, 396, 427, 455 Argus-Spectrum 242, 396, 427, 457 ATEIS Middle East FZCO 245, 397, 427, 459 ATOM KABLO SANAYI VE TICARET A.S. 547 Autronica Fire & Security AS 248, 428, 460 B Bahra Cables Company 549 Bailey Maintenance 210 Banham Alarms (Prop Banham Patent Locks Limited) 616 Bardic by Honeywell (Novar Systems Ltd) 21, 248, 461 BBC Fire Protection Limited 210 Beijing Leader Huaxin Electronics Co. Ltd 22, 249 Beijing VSAIL Fire Protection Equipment Co Ltd 249, 461 Bentel Security s.r.l. 397 BERICA CAVI S.p.A. 550 Biamp Systems Corporation 22 Bosch Security Systems BV 24 Bristol Fire Ltd 250, 397, 462 Building Protection Systems (NI) Limited 25 C CAMS Fire & Security PLC 210 Carillion (Novar Systems Ltd) 28 Cavicel SpA 550 Ceasefire Industries Ltd 251, 398, 462 Channel Safety Systems Ltd 29 Chiron Security Communications Limited 622 Chubb Fire & Security Limited 210 Chubb Fire & Security Ltd 428 Chubb Fire and Security Limited 623 20 Oct 2014 Chubb Fire Ltd 251 Clymac Limited 210 Computionics Limited (Trading as C-Tec) 30 Consilium Marine and Safety AB 252 Context Plus Ltd 35, 252, 398, 428, 553 Control Equipment Limited 4, 37, 253, 398, 429, 463 Cooper Fulleon Limited 399, 465 Cooper Industries Inc 45, 399 Cooper Lighting and Safety Ltd 46, 400, 466 Cooper MEDC Ltd 468 Cooper Safety 254 Cooper Sécurité SAS 257 Cranford Controls Limited 468 CSL DualCom Limited 621 CTM Fire and Security Limited 210 D Daemon Fire and Security Limited 211 Dätwyler Cabling Solutions AG 554 Defensor Group Limited 211 Detector Electronics Corporation 49, 259, 429 Digital Security Controls, a Division of Tyco Safety Products Canada Ltd 382 Direction Fire Limited 211 Doncaster Cables 555 Draka (Malaysia) Sdn. Bhd. 556 Draka UK Limited 557 Dubai Cable Company (Private) Limited, Trading as Ducab 562, 563, 566 E EA-RS Group Limited 211 EDS Elektronik Destek San. ve Tic. Ltd. Şti. 259 Eland Cables 566 Elmdene International Ltd 469 EMCOR Facilities Services Limited, EMCOR Specialist Services 211 EMCS - East Midlands Central Station Limited 616 Emergi-Lite Safety Systems (Thomas & Betts Ltd) 259, 400 Emico Limited 211 Emirates Fire Fighting Equipment Factory L.L.C. (FIREX) 261, 400, 470, 567 Emirates Fire Protections Equip. Factory. TR. Section 51, 261, 401, 430, 470 ESYLUX GmbH 382 Eurofyre Limited 262 Eurotech Fire Systems Limited 53, 263, 401, 430, 471 Everday Technology Co. Limited 265, 383, 401 Eyston Company Ltd 384 F Fike Safety Technology Ltd 55, 267, 402, 431, 472 Finder Elektronik A.S. 270, 402, 431, 473 Fire Fighting Enterprises Ltd 272 Fireblitz Extinguisher Ltd 384 Fireguard Safety Equipment Co Ltd 272, 403, 474, 568 Firelite by Honeywell (Pittway Systems Technology Group (Europe) Ltd) 58, 273 ix INDEX Fireonica Co. Ltd 274, 403 Firesafe 59, 384, 568 Firetecnics Systems Limited 212 Fsc Export Ltd 274, 403, 474 G GBE Fire & Security (a division of GB Electronics Limited) 212 Gent By Honeywell (Novar Systems Ltd) 60, 275, 404, 431, 475 GEZE GmbH 282, 432 Gira Giersiepen Gmbh & Co. KG 385 Global Fire Equipment S.A. 404, 478 Global Fire Systems Limited trading as Global Fire & Security Systems 212 Grainger Fire Systems 212 Grupo General Cable Sistemas, S.A. 569 Grupo General Cable Sistemas, S.L. 570 Gulf Security Technology Co., Ltd. 65, 282, 405, 432, 478 Gutkes GmbH 385 H Haes Systems Limited 69, 284, 405, 432, 479 Hall & Kay Fire Engineering (Ashford) 212 HDR 285, 405, 433, 480 Hochiki America Corporation 286 Hochiki Corporation 287 Hochiki Europe (UK) Limited 288, 406, 433, 483 Honeywell Automation (I) Pvt. Ltd 294 Honeywell Control Systems Limited 296, 435 Honeywell Control Systems Ltd 74, 298, 406, 435 Honeywell International Inc 79 Honeywell Life Safety Systems (Novar Systems Ltd) 299 Horing LIH Industrial Co Ltd 300, 407, 493 Hosiden Besson Limited 494 Huzhou Jiusheng Electric Co Ltd 571 I I.C. Service & Maintenance Limited 213 Iceberg Building Services Limited 213 INIM Electronics s.r.l. 302, 407, 435 Intelligent Safety & Security Technology Ltd. 303, 407, 494 J Jalo Helsinki Oy / Jalo Ltd 386 Jaylow Supplies Ltd 572 John Lewis Partnership 386 K KAC Alarm Company Limited 408, 495 Kentec Electronics Limited 82 Keystone Electric Wire & Cable Company Ltd 573 Kidde Finland Oy 386 Kidde Products Ltd 304, 412, 436 Kidde Products Ltd, trading as AirSense Technology 305 Kidde Safety Europe Ltd 387 Kingfell Engineering Limited 213 Kingfisher Security (UK) Limited trading as Kingfisher Fire & Security 213 KME Italy SpA 574 x L Labor Strauss Sicherungsanlagenbau GmbH 306, 412, 507 LEONI Studer AG 576 Lichfield Fire & Safety Equipment Co. Ltd (LIFECO) 307 Lloret Fire and Security Limited 213 M M. J. Quinn Integrated Services Limited 213, 214 Mavili Elektronik Ticaret Ve Sanayi A.S. 83, 308 MECE Fire & Security Limited 214 Mercury Engineering 214 MGC Systems Corp. 413 MICC (Shanghai) Electric Co Ltd 581 Mineral Insulated Cable Co Ltd 582 MITIE Technical Facilities Management Limited 214 MITIE Technical Facilities Management Limited (MITIE Fire and Security Systems) 214 Morley-IAS Fire Systems By Honeywell 87, 308 Morley-IAS Fire Systems by Honeywell (Pittway Systems Technology Group (Europe) Ltd) 88, 310, 413, 436, 508 Multron Systems Pte Ltd 91, 313, 414, 436, 513 N NAJD ELECTRICALS & SAFETY EQUIPMENT TRADING 583 National Monitoring (Prop. AVR Group Limited)617 Nexans Schweiz AG 584 Nexans Sweden AB 584 Nexans Turkiye Endustri ve Ticaret A.S. 585 NG Bailey Limited - Rail Division 214 NINGBO LONGMAX ELECTRONIC CO., LTD 387 Ningbo Siterwell Electronics Co., Ltd. 389 Nitin Ventures FZE 93, 314, 414, 437, 514, 586 Nittan Europe Limited 315 Norden Communication UK Ltd 586 Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd)6, 94, 316, 414, 437, 514 Notifier Fire Systems India 319 O Olympia Electronics S.A. 99, 320 OLYMPIC CABLE COMPANY SDN. BHD. 588 Oman Cables Industry (SAOG) 588 Orient Corporation Pte. Ltd. 100, 321, 516 P Panasonic Corporation 321, 437 PEL Services Limited 215 Pelco Finland Oy 101, 322, 415, 438, 516 Pentair Thermal Management Canada Limited 589 Pentair Thermal Management UK Limited 591 Philton Fire & Security Limited 324 Photain Controls 103 Pittway Tecnologica Srl. 324, 438 Plana Fabrega 329 Protec Fire Detection plc 104, 215, 330, 415, 439, 517 Prysmian Cables & Systems Limited 592, 599 20 Oct 2014 INDEX PX Manufacturing & Distribution Company Limited 601 R RAMCRO S.p.A. (including RAMCRO S.p.A. Trading as B3 Cables Solution) 601 Ravel Electronics Ltd 334, 416, 518 S Sabre Fire & Security Ltd 389 Safety Hi-Tech Srl 335, 439 Safety Technology International (Europe) Limited 416 Safex Fire Services Limited 335 Sareme UAB 336, 416 SAXA, Inc 518 Schlumberger Oilfield UK PLC, Sensor Highway Limited (Schlumberger, Southampton) 337 Schneider Electric Buildings Sweden AB 108 Schneider Electronic Buildings AS 108 Schrack Seconet AG 417 Scotshield Limited 215 secudo GmbH 390 Securiton AG 417 Sensetech Systems Limited 215 Shakun Polymers Limited 603 Shenzhen Fanhai Sanjiang Electronics CO., Ltd 390 Shenzhen Heiman Technology Co Ltd 337 SHIELD FIRE, SAFETY AND SECURITY LIMITED 439, 604 SHIELD FIRE, SAFETY AND SECURITY LTD109, 338, 417, 440, 519, 604 Siemens plc, Building Technologies, Fire Safety Division 216 Siemens Switzerland Limited, Building Technologies Division 111, 339, 417, 440, 519 SMS (Novar Systems Ltd) 121, 346, 419, 442, 521 Southern Monitoring Services Limited 617 Sprue Safety Products Ltd 390 Static Systems Group Plc 216 Sterling Safety Systems 349, 419, 442, 521 Synaps Technology Srl 420 System Sensor 352 System Sensor Europe 352, 523 System Sensor Europe, Life Safety Distribution AG 523 System Sensor, Honeywell International (I) PVT. Limited 352 T T Clarke Public Limited Company 216 20 Oct 2014 T V F (UK) Limited 216 Tai Sin Electric Limited 605 Tanda Technologies (Singapore) Pte Ltd 356 Teledata S.r.l. 356, 420, 528 TELE-FONIKA Kable Sp. z o.o., S.K.A. 606 Teletek Electronics JSC 358 Texecom Ltd 529 Thameside Fire Protection Co. Limited 216 Thorn Security Limited, Trading as Tyco Safety Product 123 Thorn Security Limited, trading as Tyco Safety Products 358, 420, 442, 533 Tratos Cavi SpA 609 Trinity Fire and Security Systems Ltd (Abingdon) 216 Trinity Fire and Security Systems Ltd (Exeter) 217 Trinity Fire and Security Systems Ltd (Honiley) 217 Turk Prysmian Kablo ve Sistemleri A.S. 610 Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited) 217 U Union Cable Company Ltd 611 UniPOS Ltd 364 UTC CCS Manufacturing Polska, Sp. Zo.o 137 UTC Fire & Security (Africa) trading as Ziton 171 UTC Fire & Security (Pty) LTD Trading as Ziton 171 UTC Fire & Security BV 172, 365, 421, 443 UTC Fire & Security BV. 623 UTC Fire & Security Inc. Trading as Edwards Systems Technology 200, 367, 422, 444, 535 V Ventcroft Limited 612 Vimpex Limited 445, 536 Vipond Fire Protection Limited 218 Visonic 392 VRC Terofire Products 369 W Wagner Group GmbH 369 WebWayOne Ltd 624 Wrexham Mineral Cables 614 X Xtralis Pty Limited 204, 372 Z Zarja Elektronika d.o.o 204 Zeta Alarm Systems by GLT Exports Limited 205, 378, 392, 423, 446, 537 xi Part 1 FIRE DETECTION AND ALARM PRODUCTS, SYSTEMS & CABLES PART 1: FIRE DETECTION AND ALARM PRODUCTS, SYSTEMS & CABLES INTRODUCTION A working fire detection and alarm system will increase the level of safety in a building by automatically warning occupants of fire before they would otherwise detect it. To ensure the system works, the system must be designed correctly, products must be correctly selected and the systems must be correctly installed and maintained. It is recommended that all systems are designed, installed, commissioned and maintained by contractors who are approved by LPCB to LPS 1014 and that they are connected to Alarm Receiving Centres approved to LPS 1020. Listings in this section include: Products Control and indicating equipment including voice alarm and power supplies Wireless, flame, beam, aspirating, smoke, heat and multi-sensor detectors Manual call points Line units including input and output devices Alarm warning devices including visual alarms, loudspeakers and sounders Cables Alarm transmission equipment Signalling systems Products are approved in accordance with a range of standards. The details of these standards are given at the front of each section relevant to the product. Some of the above products may be hard wired or wireless (Radio link). Wireless products should also be approved to EN 54-25. Systems Fire detection and alarm systems are approved for system compatibility in accordance with: LPS 1054: Requirements and testing procedures for the approval and listing of component compatibility for fire detection and alarm systems. EN 54 - Part 13: Compatibility assessment for system components. Design, installation, commissioning and maintenance contractors Contractors are approved in accordance with: LPS 1014: Requirements for certificated fire detection and alarm system firms. LPS 1020: Alarm Receiving Centres 2 20 Oct 2014 PART 1: SECTION 2 FIRE DETECTION AND ALARM SYSTEMS A fire detection and fire alarm system is typically made up of a number of inter-linked components including detectors, manual call points, and alarm sounders connected to control and indicating equipment by means of one or more transmission paths. All system components, including the control and indicating equipment are also connected to a power supply directly or indirectly. A fire detection and alarm system may be linked to other systems such as fire protection, or building management systems. These other systems are not considered as part of the fire detection and alarm systems. The fire detection and alarm systems may be networked together. Each of the components that constitute the fire detection and alarm system may be individually tested and approved against their appropriate standard to demonstrate their own performance and reliability but in order to ensure their compatibility and performance together within the system, certain system tests and requirements must be fulfilled. The system standard specifies the requirements for compatibility and connectability assessment of system components that either comply with the requirements of EN 54 and/or with a manufacturer’s specification. The standard also includes requirements for the integrity of the fire detection and fire alarm system when connected to other systems. This section lists approved fire detection and alarm systems suitable for use in buildings for the protection of people and property. The system requirements ensure the compatibility of the different components of the system work reliably together. Each component of the fire detection and alarm systems listed in this section are approved to the applicable product standard and are listed in Sections 3, 4.1, 5, 6, and 7. The approval process for the system is outlined in scheme document SD040. Systems listed in this section have been approved to LPS 1054: 2001 Requirements for the evaluation of component compatibility for fire alarm systems This standard was designed for the UK market and applies to systems incorporating control and indicating equipment and power supply equipment complying with EN 54-2 Fire detection and fire alarm systems Control and indicating equipment and EN 54-4 Fire detection and fire alarm systems - Power supply equipment respectively. Networked systems are evaluated by ensuring that each control panel connected to the network can operate as a stand alone unit, in the event of failure of the network connections, and that failure of a control panel will not affect other control panels on the network. LPCB is now accepting products for approval to EN 54-13: 2005 Compatibility assessment for system components which is applicable to the EU market and to LPS 1653: 2011 Requirement for Network fire detection and alarm systems. Note: Since LPCB uses national and international standards for the listing of products, in some instances, the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly. 20 Oct 2014 3 PART 1: SECTION 2 FIRE DETECTION AND ALARM SYSTEMS Control Equipment Limited Hillcrest Business Park, Dudley, West Midlands DY2 9AP, United Kingdom Tel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972 E-mail: [email protected] • Website: www.controlequipment.com Certificate No: 018b to LPS 1054-1 Certificate No: 018d to LPS 1054-1 Certificate No: 018u to EN 54-13: 2005 Fire Detection and Alarm Systems Certificated Products Precept fire alarm system Comprising the following products: LPCB Ref. No. 018b/S1 Control Equipment Limited Precept 2, 4, 8, 16 and 32 zone control and indicating equipment. Apollo Fire Detectors Limited 55000-100 grade 1 rate of rise heat detector (45681-200 base) 55000-200 ionization smoke detector (45681-200 base) 55000-300 photoelectic smoke detector (45681-200 base) 53531-221 grade 1 rate of rise heat detector (45681-007 base) continued 53541-151 ionization smoke detector (45681-007 base) 53541-200 photoelectric smoke detector (45681-007 base) 55000-101 grade 2 rate of rise heat detector (45681-200 base) 55000-102 grade 3 rate of rise heat detector (45681-200 base) 55000-103 range 1 rate of rise heat detector (45681-200 base) 55000-104 range 2 rate of rise heat detector (45681-200 base) 55000-210 integrating ionization smoke detector (45681-200 base) Hochiki Corporation DFE-60 grade 2 fixed temperature heat detector (YBF-RL/4H5 base) DFE-90 range 1 fixed temperature heat detector (YBF-RL/4H5 base) DCC-1EL grade 1 rate of rise heat detector (YBF-RL/4H5 base) DCC-2EL grade 2 rate of rise heat detector (YBF-RL/4H5 base) DCC-R1EL range 1 rate of rise heat detector (YBF-RL/4H5 base) Hochiki Europe SLK-E photoelectric smoke detector (YBF-RL/4H5 base) SIH-E ionization smoke detector (YBF-RL/4H5 base) KAC Alarm Company Limited KR72 manual call point. Photain Controls Limited ISD-P91 ionization smoke detector PRR-P91 grade 1 rate of rise heat detector PHD-P90 range 1 fixed temperature heat detector Signature Industries - Clifford and Snell Alarms. MCP/R/F manual call point MCP/R/S manual call point System Sensor, St. Charles, Illinois, USA. 1151E ionization smoke detector (B401 base) 2151E photoelectric smoke detector (B401 base) Discovery fire alarm system Comprising the following products: 018d/01 Control Equipment Limited Discovery analogue addressable control and indicating equipment Apollo Fire Detectors Limited 55000-400 grade 2 analogue temperature monitor 55000-420 grade 2 analogue temperature monitor 58000-400 Discovery temperature monitor 55000-600 analogue photoelectric smoke monitor 55000-620 analogue photoelectric smoke monitor 58000-600 Discovery optical smoke monitor 55000-500 analogue ionisation smoke monitor 55000-520 analogue ionisation smoke monitor 58000-500 Discovery ionisation smoke monitor 58000-700 Discovery multisensor monitor 55000-900 surface and flush mounted manual call point 55000-910 flush mounted manual call point 55000-950 waterproof addressable manual call point 58000-900 flush and surface mounted manual call point 4 20 Oct 2014 PART 1: SECTION 2 FIRE DETECTION AND ALARM SYSTEMS Certificated Products LPCB Ref. No. 58000-910 flush mounted manual call point 58000-920 surface mounted manual call point 55000-700 XP95 short circuit isolator 45681-321 XP95 negative isolating base 45681-210 XP95 addressable mounting base FireClass Fire Detection System Comprising the following products: 018u/01 Commercial Detectors FC460P Digital addressable photoelectric smoke detector (4B, 4B-I and 5B bases) FC460PH Digital addressable photoelectric smoke and Class P heat detector (4B, 4B-I and 5B bases) FC460PC Digital addressable photoelectric smoke, Class P heat and carbon monoxide detector (4B, 4B-I and 5B bases) FC460H Digital addressable Class P heat detector (4B, 4B-I and 5B bases) Manual Call Points FC420CP Addressable Type A indoor manual call point FC421CP Addressable Type A outdoor manual call point Line Units 4B-I Short circuit isolator base FC410QIO Quad input/output module with short circuit isolator FC410QRM Quad relay module with short circuit isolator FC410QMO Quad monitored output module with short circuit isolator Alarm Warning Devices FC410LPSYR Addressable loop powered Type A sounder (red) with short circuit isolator FC410LPSYW Addressable loop powered Type A sounder (white) with short circuit isolator FC410LPSY Addressable loop powered Type B sounder (red) with short circuit isolator FC410LPAVR Addressable loop powered Type A sounder beacon (red) with short circuit isolator FC410LPAVW Addressable loop powered Type A sounder beacon (white) with short circuit isolator FC410LPAV Addressable loop powered Type B sounder beacon (red) with short circuit isolator FC430LPASB Loop powered sounder beacon base with short circuit isolator FC430LPSB Loop powered sounder base with short circuit isolator FC430SB Analogue addressable type A sounder base Control and Indicating Equipment FC32-1 FireClass (557.200.701) Analogue Addressable Control and Indicating Equipment, 1 loop, 32 Zone FC64-2 FireClass (557.200.702) Analogue Addressable Control and Indicating Equipment, 2 loop, 64 Zone FC64-4 FireClass (557.200.703) Analogue Addressable Control and Indicating Equipment, 4 loop, 64 Zone FC240-2 FireClass (557.200.704) Analogue Addressable Control and Indicating Equipment, 2 loop, 240 Zone FC-240-4 FireClass (557.200.705) Analogue Addressable Control and Indicating Equipment, 4 loop, 240 Zone Bases: 4B Universal mounting base 4B-I Isolator base 5B Standard mounting base General note: For further information on each individual product including approved sensitivities, heat classification, sounder tones etc, refer to model reference number(s) in the appropriate section of the Red Book or on www.redbooklive.com 20 Oct 2014 5 PART 1: SECTION 2 FIRE DETECTION AND ALARM SYSTEMS Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd) Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888 E-mail: [email protected] • Website: www.notifierfiresystems.co.uk Certificate No: 154e to lps 1054: Issue 2.1 Certificated Products Notifier NFS2-8 Fire Alarm System LPCB Ref. No. 154e/S1 Comprising the following products: Notifier Fire Systems Ltd 124-345-002 NFS2-8, 2 Zone Conventional Control and Indicating Equipment 124-345-004 NFS2-8, 4 Zone Conventional Control and Indicating Equipment 124-345-008 NFS2-8, 8 Zone Conventional Control and Indicating Equipment Morley-IAS Fire Systems ECO 1002 Photoelectric smoke and heat detector ECO 1003 Photoelectric smoke detector ECO 1004T High Temperature 78C heat detector class BS ECO 1005 Heat detector class A1R ECO 1005T Fixed temperature heat detector class A2S KAC Alarm Company Ltd MCP1A-Rxxxxx Indoor/outdoor surface/flush mounting conventional manual call point NS4/R Sounder 4 tone wall mounting conventional (red) NS4/W Sounder 4 tone wall mounting conventional (white) NS14/R Sounder 14 tones wall mounting conventional (red) NS14/W Sounder 14 tones wall mounting conventional (white) 6 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Control and Indicating Equipment (CIE) is a component of a fire detection and alarm system through which other components may be connected to it such as detectors, manual call points, sounders, routing equipment, voice alarm equipment and fire protection equipment. It is supplied with power from power supply equipment which may be housed within the CIE enclosure or a separate enclosure. CIE is used to receive and send out signals that are related to fire. CIE also monitors the system for faults (short and open circuit or power supply faults) and indicates the status of the fire detection and alarm system. CIE designed to meet a European standard such as EN 54-2 or international standard such as ISO 7240-2 has certain options with requirements. For example, it may be designed to provide a signal to fire protection equipment or have dependencies on more than one alarm signal. Some CIEs have other functions which are not specified in the standard. These additional features are normally assessed such that they do not jeopardise compliance. The choice of CIE is dependent on the specific applications as recommended in the application guidelines for a specific job or building. Some CIEs have associated repeaters or mimic panels. These are normally used to repeat the indications given on the main CIE and sometimes they have control functions such as silencing sounders. There are no published standards that these repeaters or mimics can be tested against. Voice Alarm Control and Indicating Equipment (VACIE) is a component of the fire alarm system which receives signals from the CIE or via manual control in order to activate messages via loudspeakers. VACIE may also include emergency microphone to broadcast live messages. The approval processes for this type of equipment is outlined in scheme document SD040. This section lists Control and Indicating Equipment, Voice Alarm Control and Indicating Equipment and power supply equipment approved for use in fire detection and fire alarm systems in buildings. Repeaters or mimics that are listed in this section are only approved with their associated CIE and are subjected to the same environmental tests as the CIE. The approval processes for this type of equipment is outlined in scheme document SD040. Products listed in this section have been approved to: EN 54-2: 1997 Control and Indicating Equipment; EN 54-2: 1997 + A1: 2006 Control and Indicating Equipment; EN 54-4: 1997 Power supply equipment; EN 54-4: 1997 + A1: 2002 and A2: 2006 Power supply equipment; ISO 7240-2: 2003 Control and Indicating Equipment; ISO 7240-4: 2003 Power supply equipment; EN 54-16:2008 Voice Alarm Control and Indicating Equipment. Audit: Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: 1. EN 54-2: 1997 is a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market from 1 August 2009. It is therefore recommended that control and Indicating Equipment are certificated to EN 54-2: 1997 + A1: 2002 2. EN 54-4: 1997 is a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market from 1 August 2009. It is therefore recommended that power supply equipment are certificated to EN 54-4: 1997 + A1: 2002 and A2: 2006. 3. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly. 20 Oct 2014 7 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT 4. Where the Control and Indicating Equipment is of modular construction, and the use of certain modules (or printed circuit boards PCBs) is optional, these are listed with the applicable equipment. ADI (ADEMCO) Via della Resistenza, 53/59 20090 Buccinasco, Milano, Italy Tel: +3902457179229 • Fax: +390245701034 E-mail: [email protected] • Website: www.adiglobal.com Certificate No: 429c-(cl-1) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Control and indicating equipment Certificated Products CXN-1-S CXN-2-M Single loop control and indicating equipment 714-001-111 PANEL DXc1-S SINGLE LOOP REGION 1 (UK & Iceland) 714-001-112 PANEL DXc1-S SINGLE LOOP REGION 2 (Iberia, India & ME) 714-001-113 PANEL DXc1-S SINGLE LOOP REGION 3 (Dutch, French, Italian, Slovenian) Incorporating as modular units: 124-410-001 Base PCB 1 Loop 124-411 Display PCB 010-115 PSU RS-50-24 Two loop control and indicating equipment 714-001-221 PANEL DXc2-M TWO LOOP REGION 1 (UK & Iceland) 714-001-222 PANEL DXc2-M TWO LOOP REGION 2 (Iberia, India & ME) 714-001-223 PANEL DXc2-M TWO LOOP REGION 3 (Dutch, French, Italian, Slovenian) LPCB Ref. No. 429c/13 429c/14 Incorporating as modular units: CXN-4-M 124-410-001 Base PCB 1 Loop 124-411 Display PCB 010-115 PSU RS-50-24 Four loop control and indicating equipment 714-001-241 PANEL DXc4-M FOUR LOOP REGION 1 (UK & Iceland) 714-001-242 PANEL DXc4-M FOUR LOOP REGION 2 (Iberia, India & ME) 714-001-243 PANEL DXc4-M FOUR LOOP REGION 3 (Dutch, French, Italian, Slovenian) 429c/15 Incorporating as modular units: 124-410 Base PCB 2 Loop 124-411 Display PCB 124-417 2 Loop PCB 010-116 PSU RS-100-24 Incorporating as optional modular units: 795-099 KIT DXc NETWORK CARD 795-102 KIT DXc 40 ZONE LED CARD 795-103 KIT DXc 80 ZONE LED CARD WITH COVER 795-111 KIT DXc 2 LOOP EXPANSION CARD (Applicable to the two loop CIE only) 795-117 KIT DXc PERFORMANCE CARD 795-118 KIT DXc KEYSWITCH 795-122 KIT DXc RS232 795-123 KIT DXc RS485 795-124 KIT DXc 80 ZONE LED CARD Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal-Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each addressable point 10 Test condition 8 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. CXN-1-M Single loop control and indicating equipment 714-001-111 PANEL DXc1-S SINGLE LOOP REGION 1 Iceland) 714-001-112 PANEL DXc1-S SINGLE LOOP REGION 2 (Iberia, India & ME) 714-001-113 PANEL DXc1-S SINGLE LOOP REGION 3 (Dutch, French, Italian, Slovenian) 714-001-114 PANEL DXc1-S SINGLE LOOP REGION 4 (German) 429c/16 (UK & Incorporating as modular units: 124-410-001 Base PCB 1 Loop 124-411 Display PCB 010-115 PSU RS-50-24 Advanced Electronics Limited 34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United Kingdom Tel: +44 (0)1670 707 111 • Fax: +44 (0)1670 707 222 E-mail: [email protected] • Website: www.Advel.co.uk Certificate No: 018c to EN 54:Part 2 and 4: 1997 Certificate No: 544b to EN54-2: 1997+A1:2006 EN54-4: 1997+A1-2002+A2:2006 Control and indicating equipment Certificated Products Mx-1002 Mx-1004 Mx-1008 20 Oct 2014 2 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 4 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment LPCB Ref. No. 018c/02 018c/03 018c/04 9 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products Mx-1016 Mx-1032 Mx-1108 LPCB Ref. No. 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 16 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1629 Display board C1632 16 Zone Expansion board C1652 5A Power supply board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board 018c/05 018c/06 018c/R01 Mx-1116 16 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board 018c/R02 Mx-1132 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1629 Display board C1631 Repeater interface board 018c/R03 QuickZone 2 and 4 Zone conventional control and indicating equipment QuickZone 2 (QZ-2) Incorporating as modular units: TPC A01- QuickZone 2 (QZ-2) main PCB applicable on 2 zone CIE only TPC A02 QuickZone LED display PCB PSM1.5 - 24 Power supply 1.5A rated Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.1 Dependency on more than one alarm signal type A 10 Test condition QuickZone 4 (QZ-4) Incorporating as modular units: TPC A01- Quick Zone 4 (QZ-4) main PCB applicable on 4 zone CIE only TPC A02 QuickZone LED display PCB PSM1.5 - 24 Power supply 1.5A rated Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.1 Dependency on more than one alarm signal type A 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 4, 8 and 12 Zone conventional control and indicating equipment QuickZoneXL 4 Conventional Control Panel (QZXL-4) Incorporating as modular units: 544b/01 QuickZone XL 10 544b/02 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. TPCA01-X4 QuickZoneXL 4 Zone Main PCB TPCA03 QuickZoneXL Display Board PSM3.0-24 Power Supply QuickZoneXL 8 Conventional Control Panel (QZXL-8) Incorporating as modular units: TPCA01-X4 QuickZoneXL 4 Zone Main PCB TPCA03 QuickZoneXL Display Board QZXL-ZEC QuickZoneXL Standard 4 Zone Extension Board PSM3.0-24 Power Supply QuickZoneXL 8 Conventional Control Panel (QZXL-8HS) Incorporating as modular units: TPCA01-X4 QuickZoneXL 4 Zone Main PCB TPCA03 QuickZoneXL Display Board QZXL-HSZEC QuickZoneXL High Spec 4 Zone Extension Board PSM3.0-24 Power Supply QuickZoneXL 12 Conventional Control Panel (QZXL-12) TPCA01-X4 QuickZoneXL 4 Zone Main PCB TPCA03 QuickZoneXLDisplay Board QZXL-ZEO QuickZoneXL Standard 4 Zone Extension Board QZXL-ZEC QuickZoneXL High Spec 4 Zone Extension Board PSM3.0-24 Power Supply QuickZoneXL 12 Zone Conventional Control Panel (QZXL-12HS) TPCA01-X4 QuickZoneXL 4 Zone Main PCB TPCA03 QuickZoneXL Display Board QZXL-HSZEC Two QuickZoneXL Standard 4 Zone Extension Board PSM3.0-24 Power Supply Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.1 Dependency on more than one alarm signal type A 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Ajax Chubb Varel B.V. Cruquiusweg 118, 1019 AK, Amsterdam, The Netherlands Tel: +31205909500 • Fax: +31205909599 E-mail: [email protected] • Website: www.ajaxchubbvarel.nl Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products 809-250450 Two zone conventional control and indicating equipment LPCB Ref. No. 176b/10 Incorporating the units: RPF0702005 Power supply PCB SPF0724851 2 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 809-250451 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Four zone conventional control and indicating equipment 176b/11 Incorporating the units: RPF0702005 Power supply PCB SPF0724853 4 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 20 Oct 2014 11 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products 809-250452 LPCB Ref. No. 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment 176b/12 Incorporating the units: RPF0702005 Power supply PCB SPF0724855 8 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition AMPAC Europe Limited Unit 2, Waterbrook Estate, Waterbrook Road, Alton, Hampshire GU34 2UD, United Kingdom Tel: +44 (0)1420 592070 • Fax: +44 (0)1420 592071 E-mail: [email protected] • Website: www.ampac.net Certificate No: 952a to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 952b to EN 54-2: 1997 + A1: 2006, EN 54-4: 1998 + A1: 2002 + A2: 2006 Certificate No: 810a-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Control and Indicating Equipment Certificated Products Zonefinder 2 and 4 Zone conventional control and indicating equipment 2183-0201, 2 Zone conventional control and indicating equipment LPCB Ref. No. 810a/03 Incorporating as modular units: TPC A01- E2 ZoneFinder two zone main PCB applicable on 2 zone CIE only TPC A02 ZoneFinder LED display PCB PSM1.5 - 24 Power supply 1.5A rated Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.1 Dependency on more than one alarm signal type A 10 Test condition 2183-0401, 4 Zone conventional control and indicating equipment Incorporating as modular units: TPC A01- E4 ZoneFinder four zone main PCB applicable on 4 zone CIE only TPC A02 ZoneFinder LED display PCB PSM1.5 - 24 Power supply 1.5A rated Certified with the following options with requirements from EN 54 Part 2: Zonefinder Plus 7.8 Output to fire alarm devices 7.12.1 Dependency on more than one alarm signal type A 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2, 4, 6, 8 and 12 Zone conventional control and indicating equipment 810a/04 2183-0202, 2 Zone Conventional Control Panel Incorporating as modular units: TPCA01-X 2 ZoneFinder Plus 2 Zone Main PCB 12 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. TPCA03 ZoneFinder Plus Display Board PSM3.0-24 Power Supply 2183-0402, 4 Zone Conventional Control Panel Incorporating as modular units: TPCA01-X4 ZoneFinder Plus 4 Zone Main PCB TPCA03 ZoneFinder Plus Display Board PSM3.0-24 Power Supply 2183-0604, 6 Zone Conventional Control Panel Incorporating as modular units: TPCA01-X2 ZoneFinder Plus 2 Zone Main PCB TPCA03 ZoneFinder Plus Display Board TPCA04-H ZoneFinder Plus High Spec 4 Zone Extension Board PSM3.0-24 Power Supply 2183-0602, 6 Zone Conventional Control Panel Incorporating as modular units: TPCA01-X2 ZoneFinder Plus 2 Zone Main PCB TPCA03 ZoneFinder Plus Display Board TPCA04-S ZoneFinder Plus Standard 4 Zone Extension Board PSM3.0-24 Power Supply 2183-0804, 8 Zone Conventional Control Panel Incorporating as modular units: TPCA01-X4 ZoneFinder Plus 4 Zone Main PCB TPCA03 ZoneFinder Plus Display Board TPCA04-H ZoneFinder Plus High Spec 4 Zone Extension Board PSM3.0-24 Power Supply 2183-0802, 8 Zone Conventional Control Panel Incorporating as modular units: TPCA01-X4 ZoneFinder Plus 4 Zone Main PCB TPCA03 ZoneFinder Plus Display Board TPCA04-S ZoneFinder Plus Standard 4 Zone Extension Board PSM3.0-24 Power Supply 2183-1204, 12 Zone Conventional Control Panel Incorporating as modular units: TPCA01-X4 ZoneFinder Plus 4 Zone Main PCB TPCA03 ZoneFinder Plus Display Board TPCA04-S Qty 2x ZoneFinder Plus High Spec 4 Zone Extension Board TPCA04-H ZoneFinder Plus High Spec 4 Zone Extension Board PSM3.0-24 Power Supply 2183-1202, 12 Zone Conventional Control Panel Incorporating as modular units: TPCA01-X4 ZoneFinder Plus 4 Zone Main PCB TPCA03 ZoneFinder Plus Display Board TPCA04-S ZoneFinder Plus Standard 4 Zone Extension Board PSM3.0-24 Power Supply 2183-1206 12 Zone Conventional Control Panel Incorporating as modular units: TPCA01-X4 ZoneFinder Plus 4 Zone Main PCB TPCA03 ZoneFinder Plus Display Board TPCA04-H Qty 2x ZoneFinder Plus High Spec 4 Zone Extension Board PSM3.0-24 Power Supply Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.1 Dependency on more than one alarm signal type A 20 Oct 2014 13 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LoopSense 8281-0105 LPCB Ref. No. 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. One loop, 32 Zone analogue addressable control and indicating equipment. 952a/01 Incorporating the following units: BRD82MBA BRD82ZICC PSU2397 ASS82ZICC Main Termination Board Zone Interface & Control Card Power Supply Unit Zone Indicator & LCD Assembly (8210) Certificated with the following options with requirements from EN54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. LoopSense 8281-0205 Two loop, 32 Zone analogue addressable control and indicating equipment. 952a/02 Incorporating the following units: BRD82MBA BRD82ZICC PSU2397 8210-0001 BRD82LSD ASS82ZICC Main Termination Board Zone Interface & Control Card Power Supply Unit 2nd loop activation Key Loop Activation Board Zone Indicator & LCD Assembly (8210) Certificated with the following options with requirements from EN54-2: 8681-0108 FireFinder Plus 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. One loop, 32 Zone analogue addressable control and indicating equipment 952b/01 Incorporating as modular units: BRD68BPSC4-A FFP BRD86DLTB4-A FFP BRD86FPB5-B FFP BRD86MBA4-A FFP BRD86MCPU4-B FFP BRD43ZAMC2-A PSU1888 Brigade & Power supply control board (8610) Dual loop termination board (8610) Front panel board EN54 (8610) Main board LCD (8610) Main 64MB CPU card (8610) 32 Zone alarm MIMIC internal card (4310) Power supply 5A (8610) Optional Modules: 14 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 8681-0208 FireFinder Plus 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Two loop, 32 Zone analogue addressable control and indicating equipment 952b/02 Incorporating as modular units: BRD68BPSC4-A FFP BRD86DLTB4-A FFP BRD86FPB5-B FFP BRD86MBA4-A FFP BRD86MCPU4-B FFP BRD86SCB3-A FFP BRD43ZAMC2-A PSU1888 Brigade & Power supply control board (8610) Dual loop termination board (8610) Front panel board EN54 (8610) Main board LCD (8610) Main 64MB CPU card (8610) Slave CPU card (8610) 32 Zone alarm MIMIC internal card (4310) Power supply 5A (8610) Optional Modules: BRD43EZC2-A BRD43ZAMC2-A 8 Zone conventional module (4310) 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 8681-0308 FireFinder Plus 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Three loop, 32 Zone analogue addressable control and indicating equipment 952b/03 Incorporating as modular units: BRD68BPSC4-A FFP BRD86DLTB4-A FFP BRD86FPB5-B FFP BRD86MBA4-A FFP BRD86MCPU4-B FFP BRD86SCB3-A FFP BRD43ZAMC2-A PSU1888 Brigade & Power supply control board (8610) Two Dual loop termination boards (8610) Front panel board EN54 (8610) Main board LCD (8610) Main 64MB CPU card (8610) Two Slave CPU cards (8610) 32 Zone alarm MIMIC internal card (4310) Power supply 5A (8610) Optional Modules: BRD86DLTB4-A FFP BRD86SCB3-A FFP BRD43EZC2-A BRD43ZAMC2-A Dual loop termination board (8610) Slave CPU cards (8610) 8 Zone conventional module (4310) 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.11 7.12.1 20 Oct 2014 Output to fire alarm devices Output to fire alarm routing equipment Alarm confirmation input from fire alarm routine equipment Delay to outputs Dependencies on more than one alarm signal - Type A 15 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.12.2 7.12.3 8.3 8.9 9.5 10 Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Fault signal from points Output to fault warning routing equipment Disablement of each addressable point Test condition Incorporating as modular units: BRD68BPSC4-A FFP Brigade & Power supply control board (8610) BRD86DLTB4-A FFP Two Dual loop termination boards (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86SCB3-A FFP Two Slave CPU cards (8610) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610) Optional Modules: BRD86DLTB4-A FFP Dual loop termination board (8610) BRD86SCB3-A FFP Slave CPU cards (8610) BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 8681-0408 FireFinder Plus 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Four loop, 32 Zone analogue addressable control and indicating equipment 952b/04 Incorporating as modular units: BRD68BPSC4-A FFP BRD86DLTB4-A FFP BRD86FPB5-B FFP BRD86MBA4-A FFP BRD86MCPU4-B FFP BRD86SCB3-A FFP BRD43ZAMC2-A PSU1888 Brigade & Power supply control board (8610) Two Dual loop termination boards (8610) Front panel board EN54 (8610) Main board LCD (8610) Main 64MB CPU card (8610) Three Slave CPU cards (8610) 32 Zone alarm MIMIC internal card (4310) Power supply 5A (8610) Optional Modules: BRD86DLTB4-A FFP BRD86SCB3-A FFP BRD43EZC2-A BRD43ZAMC2-A Dual loop termination board (8610) Slave CPU cards (8610) 8 Zone conventional module (4310) 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.11 7.12.1 7.12.2 7.12.3 8.3 8.9 9.5 10 16 Output to fire alarm devices Output to fire alarm routing equipment Alarm confirmation input from fire alarm routine equipment Delay to outputs Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Fault signal from points Output to fault warning routing equipment Disablement of each addressable point Test condition 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT AMPAC Technologies PTY Ltd 7 Ledgar Road, Balcatta 6021, Australia Tel: +618 (9242) 3333 • Fax: +618 (9242) 3334 E-mail: [email protected] • Website: www.ampac.net Certificate No: 966a to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 966b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1998 + A1: 2002 + A2: 2006 Certificated Products LoopSense 8281-0105 One loop, 32 Zone analogue addressable control and indicating equipment. LPCB Ref. No. 966a/01 Incorporating the following units: BRD82MBA BRD82ZICC PSU2397 ASS82ZICC LoopSense 8281-0205 Main Termination Board Zone Interface & Control Card Power Supply Unit Zone Indicator & LCD Assembly (8210) Certificated with the following options with requirements from EN54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Two loop, 32 Zone analogue addressable control and indicating equipment. 966a/02 Incorporating the following units: BRD82MBA BRD82ZICC PSU2397 8210-0001 BRD82LSD ASS82ZICC Main Termination Board Zone Interface & Control Card Power Supply Unit 2nd loop activation Key Loop Activation Board Zone Indicator & LCD Assembly (8210) Certificated with the following options with requirements from EN54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 8681-0108 FireFinder Plus One loop, 32 Zone analogue addressable control and indicating equipment 966b/01 Incorporating as modular units: BRD68BPSC4-A FFP Brigade & Power supply control board (8610) BRD86DLTB4-A FFP Dual loop termination board (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) 20 Oct 2014 17 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610) Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 8681-0208 FireFinder Plus 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Two loop, 32 Zone analogue addressable control and indicating equipment 966b/02 Incorporating as modular units: BRD68BPSC4-A FFP Brigade & Power supply control board (8610) BRD86DLTB4-A FFP Dual loop termination board (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86SCB3-A FFP Slave CPU card (8610) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610) Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 8681-0308 FireFinder Plus 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Incorporating as modular units: 966b/03 BRD68BPSC4-A FFP Brigade & Power supply control board (8610) BRD86DLTB4-A FFP Two Dual loop termination boards (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86SCB3-A FFP Two Slave CPU cards (8610) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610) Optional Modules: BRD86DLTB4-A FFP Dual loop termination board (8610) BRD86SCB3-A FFP Slave CPU cards (8610) BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 18 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Incorporating as modular units: BRD68BPSC4-A FFP Brigade & Power supply control board (8610) BRD86DLTB4-A FFP Two Dual loop termination boards (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86SCB3-A FFP Two Slave CPU cards (8610) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610) Optional Modules: BRD86DLTB4-A FFP Dual loop termination board (8610) BRD86SCB3-A FFP Slave CPU cards (8610) BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 8681-0408 FireFinder Plus 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Four loop, 32 Zone analogue addressable control and indicating equipment 966b/04 Incorporating as modular units: BRD68BPSC4-A FFP Brigade & Power supply control board (8610) BRD86DLTB4-A FFP Two Dual loop termination boards (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86SCB3-A FFP Three Slave CPU cards (8610) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610) Optional Modules: BRD86DLTB4-A FFP Dual loop termination board (8610) BRD86SCB3-A FFP Slave CPU cards (8610) BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition 20 Oct 2014 19 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Application Solutions (Safety and Security) Ltd, East Sussex, United Kingdom Unit 17, Cliffe Industrial Estate, Lewes, East Sussex BN8 6JL, United Kingdom Tel: +44 (0) 1273 405411 • Fax: +44(0) 1273 405415 E-mail: [email protected] • Website: www.asl-control.co.uk Certificate No: 1043a to EN 54-16: 2008 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products ASL Rack mount voice alarm system Incorporating the following modules: VAR8-ACU(EN54) Network master 8x8 router VAR8(EN54) Standalone 8x8 router VAR8-E(EN54) Standalone 8x8 router with expansion board VAR4(EN54) Standalone 4x4 router VAR12(EN54) Standalone 12x12 router VAR20(EN54) Standalone 20x20 router VAR-NIA Network Interface Adaptor VIPEDIA-12 Professional Sound Life-Safety Digital Audio System BOA01 DIN Rail Mount BOA02 RJ45 Break Out Adaptor - Four Port - Straight Through VAR8 Optional Modules LPCB Ref. No. 1043a/01 VAR8 Optional modules: EFI01 Analogue input and digital output board GENT Interface Interface for VAR8-E to GENT Fire Loop VAR-ANIC Network interface for VAR8(EN54), VAR8-E(EN54) and VAR8-ACU(EN54) VAR8-EXP8 Converts VAR8(EN54) to VAR8-E(EN54) V400 V400 Amplifier frame: Amplifier frame for housing M series amplifiers and amplifier interfaces M series amplifiers: M100 100W Amplifier M200 200W Amplifier M400 400W Amplifier Amplifier interfaces for V400 mainframe: LSDDC Dual DC line surveillance interface with loop return option SSINT Standby amplifier interface X400 Amplifier frame: X400 Amplifier frame for housing MX series amplifiers MX series amplifiers: MX100 100W Amplifier MX200 200W Amplifier MX400 400W Amplifier Power supply: BPC65 65AH output power supply BPC130 130AH Output power supply BDIST Battery distribution terminals MDIST Main distribution panel Optional modules: BMB01 FMS1 FMS5 FMS10 FMS20 EMS01 EMS01-EC EMS01-MT EAP01 MT01 20 Remote I/O expander unit Firemans microphone - All call Zoneable Firemans remote microphone - 5 buttons Zoneable Firemans remote microphone - 10 buttons Zoneable Firemans remote microphone - 20 buttons Emergency microphone and accessible Mimic display for routers Emergency microphone and accessible Mimic display for routers with euro-cylinder lock EMS01 with an all-call button used to trigger an evacuation message Emergency access point - All call emergency microphone Voice alarm manual trigger 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. EMS01(MK2) EMS01-EC(MK2) EMS10 EMS10-EC EMS20 EMS20-EC EMS30 EMS40 EMS50 EMX30 MPS01-F MPS01-G MPS10-F MPS10-G MPS20-F MPS20-G MPS30-F MPS30-G MPS40-F MPS40-G MPS50-F MPS50-G MPX10 MPS01-MB Emergency microphone station - All call Emergency microphone station - All call with euro-cylinder lock Emergency microphone station - 10 Button Emergency microphone station - 10 Button with euro-cylinder lock Emergency microphone station - 20 Button Emergency microphone station - 20 Button with euro-cylinder lock Emergency microphone station - 30 Button Emergency microphone station - 40 Button Emergency microphone station - 50 Button Expansion module for EMS20 - 30 Button Desk paging and emergency microphone - 1 Button - Fist mic Desk paging and emergency microphone - 1 Button Gooseneck mic Desk paging and emergency microphone - 10 Button - Fist mic Desk paging and emergency microphone - 10 Button Gooseneck mic Desk paging and emergency microphone - 20 Button - Fist mic Desk paging and emergency microphone - 20 Button Gooseneck mic Desk paging and emergency microphone - 30 Button - Fist mic Desk paging and emergency microphone - 30 Button Gooseneck mic Desk paging and emergency microphone - 40 Button - Fist mic Desk paging and emergency microphone - 40 Button Gooseneck mic Desk paging and emergency microphone - 50 Button - Fist mic Desk paging and emergency microphone - 50 Button Gooseneck mic Microphone expansion module for MPS01 - 10 Button Wall mount bracket kit for MPS01 Certified with the following options with requirements from EN 54 Part 16: 7.6.2 Manual silencing of voice alarm condition 7.7.2 Manual reset of the voice alarm condition 7.9 Voice alarm condition output 8.3 Indication of faults related to the transmission path to the CIE (Not applicable on the GENT Interface) 8.4 Indication of faults related to voice alarm zones 10.0 Voice Alarm Manual control 12.0 Emergency microphone(s) 13.14 Redundant power amplifiers Bardic by Honeywell (Novar Systems Ltd) 140 Waterside Road, Hamilton Industrial Estate, Leicester LE5 1TN, United Kingdom Tel: +44 (0) 116 246 2212 • Fax: +44 (0) 116 246 2210 Website: www.bardic.co.uk Certificate No: 154g-(cl-3) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products Zircon 2 Zone 002-509-229 Bardic Zircon, 2 zone, region 2, black grey Incorporating the following units: 020-747 8-way relay kit 020-772 4-way monitored sounder kit LPCB Ref. No. 154g/06 Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 20 Oct 2014 21 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products Zircon 4 Zone Zircon 8 Zone LPCB Ref. No. 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition 002-509-249 Bardic Zircon, 4 zone, region 2, black grey Incorporating the following units: 020-747 8-way relay kit 020-772 4-way monitored sounder kit 154g/07 Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition 002-509-289 Bardic Zircon, 8 zone, region 2, black grey Incorporating the following units: 020-747 8-way relay kit 020-772 4-way monitored sounder kit 154g/08 Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition Beijing Leader Huaxin Electronics Co. Ltd No. 17 Rongjing Eastern Road, Economy & Technology Developed Area, Beijing 100176, China Tel: +86 10 67876681 • Fax: +86 10 67863972 E-mail: [email protected] • Website: www.beijingleader.com.cn Certificate No: 987b to EN 54-2: 1997+A1:2006EN 54-4:1997+A1:2006 Control and indicating equipment Biamp Systems Corporation 9300 S.W. Gemini Drive, Beaverton, Oregon 97008, USA Tel: +1 503 718 9212 • Fax: +1 503 626 0281 Website: www.biamp.com Certificate No: 977a to EN 54-16: 2008 Certificated Products Vocia VACIE Voice Alarm Control and Indicating Equipment LPCB Ref. No. 977a/01 Incorporating: LSI-16 / LSI-16e Life Safety Interface: 22 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 700-P630-9 LSI-16 / LSI-16e Main Board 700-P632-9 LSI-16 / LSI-16e Display Board 700-P675-9 IM-16 Input Module 700-P644-9 LSI-16 / LSI-16e Power Supply Board VA-8600c Amplifier: 700-0646-9 VA-8600 AM-600c Amplifier Module 700-0601-9 VA-8600 NM-1 Network Module 700-0598-9 VA-8600 Back Plane Board 700-0599-9 VA-8600 Power Supply Board 700-0633-9 VA-8600 Capacitor Board 700-0629-9 VA-8600 AC Inlet Board 700-0602-9 VA-8600 Display Board 700-P622-9 VA-8600 Device ID Board 700-P800-9 VFOM-1 Voice Fail Over Module VA-4030e Amplifier: 700-0675-9 VPA-1 Amplifier Module 700-0677-9 VSW-1 Transformer Switch Board 700-P680-9 VNM-1 Network Module 700-0687-9 VAS-1 Aux DC Power Supply 700-0672-9 EIC-4 Input Module 700-P681-9 VAD-1 Display Board VA-4030 Amplifier: 700-0675-9 VPA-1 Amplifier Module 700-0677-9 VSW-1 Transformer Switch Board 700-P680-9 VNM-1 Network Module 700-P684-9 VAD-2 Display Board VA-2060e Amplifier: 700-0676-9 VPA-2 Amplifier Module 700-0686-9 VSW-1 Transformer Switch Board 700-P680-9 VNM-1 Network Module 700-0687-9 VAS-1 Aux DC Power Supply 700-0689-9 EIC-2 Input Module 700-P685-9 VAD-3 Display Board VA-2060 Amplifier: 700-0676-9 VPA-2 Amplifier Module 700-0686-9 VSW-1 Transformer Switch Board 700-P680-9 VNM-1 Network Module 700-P686-9 VAD-4 Display Board WS-4 (EWS-4) Paging Micro phone: 700-P625-9 WS Main Board 700-P676-9 WS-4 (EWS-4) Switch Board WS-10 (EWS-10) Paging Microphone: 700-P625-9 WS Main Board 700-P776-9 WS-10 (EWS-10) Switch Board CI-1 Control Interface: 700-P669-9 CI-1 Main Board Certified with the following options with requirements from EN 54-16: 7.3 Audible warning 7.5 Phased evacuation 7.9 Voice alarm condition output 8.3 Indication of faults related to the transmission path to the CIE 12 Emergency microphone 13.14 Redundant power amplifiers Note: The certification is conditional upon the Vocia VACIE being supplied with power from power supplies that meet the specifications detailed in the VOCIA Reference Guide, and comply with the requirements of EN 54-4. 20 Oct 2014 23 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Bosch Security Systems BV Torenalle 49, Eindhoven 5617BA, The Netherlands Tel: +31 76 5721 240 • Fax: +31 76 5716 626 E-mail: [email protected] • Website: www.boschsecurity.com Certificate No: 1054a-(cl-1) to EN 54-16: 2008 Certificated Products PROMATRIX 8000 LPCB Ref. No. 1054a/01 Voice Alarm System Incorporating the following modules: DPM 8016 Promatrix controller PXM-MM2 Dual-channel playback module DPM AO-1 Analog audio output module DPM UI-1 Universal audio input module DPA 8150 1 x 500W Power amplifier DPA 8225 2 x 250W Power amplifier DPA 8412 4 x 125W Power amplifier DPC 8015 Call station DCS 400 DCS 19" Mounting Frame DCS 801R Conrtroller Module DCS 406R Shield Module DCS 407R AF Relay Module Ext DCS 408R Loudspeaker relay Module DCS 409R AF Relay Module DCS 412R Logic Input Module DCS 416R Analog I/O Module NRS90231 Key lock switch EB DPC Emergency button DPC 8000 series DPC 8120 Call station extension LBB1965 Plena message manager PLN-1EOL End Of Line Board EOL 8001 End Of Line Board P 64 Digital Audio Matrix N8000 Netmax System Controller AI-1 Analog Audio Input Module AO-1 Analog Audio Output Module MI-1 Microphone Input Module CM-1 Cobranet Network Module DM-1 Dante Network Module DSP-1 DSP Extension Module 300 Mips DSP-2V2 DSP Extension Module 1500 Mips DSA 8405 4 X 500 W Power Amplifier DSA 8410 4 X 1000 W Power Amplifier DSA 8805 8 X 500 W Power Amplifier CPS4.5 4 X 500 W Power Amplifier CPS4.10 4 X 1000 W Power Amplifier CPS8.5 8 X 500 W Power Amplifier RCM-810 Remote Control Module LML-1 Line Measuring Load LML-1v2 Line Measuring Load Certified with the following options with requirements from EN 54 Part 16: 7.5 Phase evacuation 7.6.2 Manual silencing of the voice alarm condition 7.7.2 Manual reset of the voice alarm condition 7.9 Voice alarm condition output 8.3 Indication of faults related to the transmission path to the CIE 8.4 Indication of faults related to voice alarm zones 10 Voice alarm manual control 12 Emergency microphone(s) 13.14 Redundant power amplifier Note: The certificate is conditional upon the PROMATRIX 8000 VOICE ALARM SYSTEM being supplied with power from power supplies that meet the power specifications detailed in the owner manuals of the certified modules, and which complies with the requirements of 24 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. EN54-4. Building Protection Systems (NI) Limited 1 Pilot's View, Sydenham Business Park, Heron Road, Belfast Harbour Estate, Belfast BT3 9LE, Ireland Tel: 00442890455111 • Fax: 00442890466111 E-mail: [email protected] • Website: www.bpsni.co.uk Certificate No: 154g-(cl-4) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products Mach 2.8 Basic Equipment Kit, (BEK): Modular analogue addressable control and indicating equipment 020-538-501 Basic Equipment Kit, Group 0 LPCB Ref. No. 154g/01 Incorporating the following as modular units: Enclosures: 020-472-009 020-473-009 020-474-009 020-475-009 020-476-009 020-480-501 020-481-009 020-508-009 020-509-009 020-576 020-577 020-621 020-621-009 020-541-501 Backbox Kit Standard Backbox Kit Extended, Black / Grey Backbox Kit Extended Deep, Black / Grey Backbox Kit Double Extended, Black / Grey Backbox Kit Double Extended Deep, Black / Grey Cover Kit Main Moulded, Black / Grey Cover Kit Extended Moulded, Black / Grey Backbox Extension Standard Assembly Black / Grey Backbox Extension Deep Assembly Black / Grey Main Cover, Stainless Steel Extension Cover Stainless Steel Zone Extension Cover, Stainless / Steel 256 Zone Extension Cover, Black / Grey PSU7A / 78Ah Battery Enclosure Modules: 020-559-001 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-002 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588 Notifier Dual Loop Interface Board, (LIB) 020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 020-648 PSU3A 020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-548 PSU7A Status Indication 020-543 Dual Transmission Path / Booster, PSU Interface 020-773 Routing Termination Unit (DEOL) 020-877 Extinguishing Interface Module M221-SI 020-643 ID²net Fibre Optic Interface Kit 020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel Notes: 1. Products are available in language variant as follows: Group 0: English with English manuals Mach 2.8 2. Fixed build products incorporate a corresponding Basic Equipment Kit. Fixed build 2 loop analogue addressable control and indicating equipment 002-530 2 Loop, PSU3A, Group 0 154g/01 Incorporating the following as modular units: Enclosures: 20 Oct 2014 25 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 020-472-009 020-473-009 020-474-009 020-475-009 020-476-009 020-480-501 020-481-009 020-508-009 020-509-009 020-576 020-577 020-621 020-621-009 020-541-501 Backbox Kit Standard Backbox Kit Extended, Black / Grey Backbox Kit Extended Deep, Black / Grey Backbox Kit Double Extended, Black / Grey Backbox Kit Double Extended Deep, Black / Grey Cover Kit Main Moulded, Black / Grey Cover Kit Extended Moulded, Black / Grey Backbox Extension Standard Assembly Black / Grey Backbox Extension Deep Assembly Black / Grey Main Cover, Stainless Steel Extension Cover Stainless Steel Zone Extension Cover, Stainless / Steel 256 Zone Extension Cover, Black / Grey PSU7A / 78Ah Battery Enclosure Modules: 020-559-001 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-002 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588 Notifier Dual Loop Interface Board, (LIB) 020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 020-648 PSU3A 020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-548 PSU7A Status Indication 020-543 Dual Transmission Path / Booster, PSU Interface 020-773 Routing Termination Unit (DEOL) 020-877 Extinguishing Interface Module M221-SI 020-643 ID²net Fibre Optic Interface Kit 020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel Notes: 1. Products are available in language variant as follows: Group 0: English with English manuals Mach 2.8 2. Fixed build products incorporate a corresponding Basic Equipment Kit. Fixed build 4 loop analogue addressable control and indicating equipment 020-905 4 Loop, PSU7A, Group 0 154g/01 Incorporating the following as modular units: Enclosures: 020-472-009 020-473-009 020-474-009 020-475-009 020-476-009 020-480-501 020-481-009 020-508-009 020-509-009 020-576 020-577 020-621 020-621-009 020-541-501 Backbox Kit Standard Backbox Kit Extended, Black / Grey Backbox Kit Extended Deep, Black / Grey Backbox Kit Double Extended, Black / Grey Backbox Kit Double Extended Deep, Black / Grey Cover Kit Main Moulded, Black / Grey Cover Kit Extended Moulded, Black / Grey Backbox Extension Standard Assembly Black / Grey Backbox Extension Deep Assembly Black / Grey Main Cover, Stainless Steel Extension Cover Stainless Steel Zone Extension Cover, Stainless / Steel 256 Zone Extension Cover, Black / Grey PSU7A / 78Ah Battery Enclosure Modules: 020-559-001 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-002 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588 Notifier Dual Loop Interface Board, (LIB) 020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 26 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 020-648 020-579 020-548 020-543 020-773 020-877 020-643 020-647 PSU3A PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) PSU7A Status Indication Dual Transmission Path / Booster, PSU Interface Routing Termination Unit (DEOL) Extinguishing Interface Module M221-SI ID²net Fibre Optic Interface Kit ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel Notes: 1. Products are available in language variant as follows: Group 0: English with English manuals Mach 2.8 2. Fixed build products incorporate a corresponding Basic Equipment Kit. Fixed build 6 loop analogue addressable control and indicating equipment 020-906 6 Loop, PSU7A, Group 0 154g/01 Incorporating the following as modular units: Enclosures: 020-472-009 020-473-009 020-474-009 020-475-009 020-476-009 020-480-501 020-481-009 020-508-009 020-509-009 020-576 020-577 020-621 020-621-009 020-541-501 Backbox Kit Standard Backbox Kit Extended, Black / Grey Backbox Kit Extended Deep, Black / Grey Backbox Kit Double Extended, Black / Grey Backbox Kit Double Extended Deep, Black / Grey Cover Kit Main Moulded, Black / Grey Cover Kit Extended Moulded, Black / Grey Backbox Extension Standard Assembly Black / Grey Backbox Extension Deep Assembly Black / Grey Main Cover, Stainless Steel Extension Cover Stainless Steel Zone Extension Cover, Stainless / Steel 256 Zone Extension Cover, Black / Grey PSU7A / 78Ah Battery Enclosure Modules: 020-559-001 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-002 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588 Notifier Dual Loop Interface Board, (LIB) 020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 020-648 PSU3A 020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-548 PSU7A Status Indication 020-543 Dual Transmission Path / Booster, PSU Interface 020-773 Routing Termination Unit (DEOL) 020-877 Extinguishing Interface Module M221-SI 020-643 ID²net Fibre Optic Interface Kit 020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel Notes: 1. Products are available in language variant as follows: Group 0: English with English manuals Mach 2.8 2. Fixed build products incorporate a corresponding Basic Equipment Kit. Fixed build 8 loop analogue addressable control and indicating equipment 020-907 8 Loop, PSU7A, Group, 78Ah Battery Enclosure 154g/01 Incorporating the following as modular units: Enclosures: 020-472-009 020-473-009 020-474-009 020-475-009 20 Oct 2014 Backbox Kit Standard Backbox Kit Extended, Black / Grey Backbox Kit Extended Deep, Black / Grey Backbox Kit Double Extended, Black / Grey 27 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 020-476-009 020-480-501 020-481-009 020-508-009 020-509-009 020-576 020-577 020-621 020-621-009 020-541-501 Backbox Kit Double Extended Deep, Black / Grey Cover Kit Main Moulded, Black / Grey Cover Kit Extended Moulded, Black / Grey Backbox Extension Standard Assembly Black / Grey Backbox Extension Deep Assembly Black / Grey Main Cover, Stainless Steel Extension Cover Stainless Steel Zone Extension Cover, Stainless / Steel 256 Zone Extension Cover, Black / Grey PSU7A / 78Ah Battery Enclosure Modules: 020-559-001 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-002 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588 Notifier Dual Loop Interface Board, (LIB) 020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 020-648 PSU3A 020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-548 PSU7A Status Indication 020-543 Dual Transmission Path / Booster, PSU Interface 020-773 Routing Termination Unit (DEOL) 020-877 Extinguishing Interface Module M221-SI 020-643 ID²net Fibre Optic Interface Kit 020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel Notes: 1. Products are available in language variant as follows: Group 0: English with English manuals 2. Fixed build products incorporate a corresponding Basic Equipment Kit. Carillion (Novar Systems Ltd) Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United Kingdom Tel: 0116 246 2000 • Fax: 0116 246 2300 Website: www.gent.co.uk Certificate No: 042bc to EN 54-2: 1997+A1:2006 and EN 54-4: 1997 + A1:2002 + A2:2006 Certificated Products CP2-AMC Two loop analogue addressable control and indicating equipment (English language) LPCB Ref. No. 042bc/04 Incorporating as modular units: 2434-859 Master Controller Board (MCB) 2434-862 Power Supply Unit 2434-762 Display and Key card (DKC) 2434-669 Loop processor card 4374-161 Text Membrane (English) 2434-861 Copper network card Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition 28 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products CP4-AMC One to Four loop analogue addressable control and indicating equipment (English language) LPCB Ref. No. 042bc/07 Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer Module 4374-157 Text Membrane (English) 2434-674 Copper network card Note: Scope of approval does not include the operation of the network card) 7.8 7.11 8.3 9.5 10 CP4-72-AMC Certified with the following options with requirements from EN 54-2: Output to fire alarm devices Delays to outputs Fault signals from points Disablement of each address point Test condition One to Six loop analogue addressable control and indicating equipment (English Language) 042bc/11 Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-992 Thermistor board 2434-860 Battery terminal board 2434-832 Power supply PCB 2434-854 Backplane PCB 2434-761 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer module 4374-157 Text Membrane (English) 2434-674 Copper network card ( Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Channel Safety Systems Ltd 9 Petersfield Business Park, Petersfield GU32 3QA, United Kingdom Tel: 08458847000 • Fax: 08458846000 E-mail: [email protected] • Website: www.chanelsafety.co.uk Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products CFP702-4/CHAN Two zone conventional control and indicating equipment LPCB Ref. No. 176b/07 Incorporating the units: RPF0702005 Power supply PCB SPF0724851 2 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 20 Oct 2014 29 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products CFP704-4/CHAN LPCB Ref. No. 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Four zone conventional control and indicating equipment 176b/08 Incorporating the units: RPF0702005 Power supply PCB SPF0724853 4 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 CFP708-4/CHAN 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment 176b/09 Incorporating the units: RPF0702005 Power supply PCB SPF0724855 8 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Computionics Limited (Trading as C-Tec) Challenge Way, Martland Park, Wigan, Lancashire WN5 OLD, United Kingdom Tel: +44 (0)1942 322744/42444 • Fax: +44 (0)1942 829867 E-mail: [email protected] • Website: www.c-tec.co.uk Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products XFP502/H XFP502/X 2 loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housing Incorporating the following units: SPF0501000 Switch mode power supply board SPF0501202 XFP Hochiki 2 loop, main motherboard SPF0501200 Display board "keypad display" Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality . 2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing Incorporating the following units: SPF0501000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501200 Display board "Keypad display" LPCB Ref. No. 176b/01 176b/02 Certified with the following options with requirements from EN54-2: 1997 30 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.8 7.11 XFP501/H XFP501/X XFP501E/H XFP501E/X 20 Oct 2014 Output to fire alarm device(s) Delays to the actioning of outputs fire alarm devices and fire routing equipment Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Alarm counter Fault signals from points Disablement of each address point Test condition 7.12.1 7.12.2 7.12.3 7.13 8.3 9.5 10 Notes: 1. Scope of approval does not include the operation of the network functionality. 1 Loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housing Incorporating the following units: SPF0501000 Switch mode power supply board SPF0501212 XFP Hochiki 1 loop, main motherboard SPF0501200 Display board "Keypad display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. 1 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing Incorporating the following units: SPF0501000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501200 Display board "keypad display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. 1 Loop, 16 zone analogue addressable control and indicating equipment using Hochiki protocol, plastic housing Incorporating the following units: SPF0702480 Switch mode power supply board SPF0501102 XFP Hochiki 1 loop, main motherboard Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality 1 Loop, 16 zone analogue addressable control and indicating equipment using Apollo 176b/03 176b/04 176b/05 176b/06 31 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Protocol, plastic housing Incorporating the following units: SPF0702480 Switch mode power supply board SPF0501101 XFP Apollo 1 loop, main motherboard CFP702-4 Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality Two zone conventional control and indicating equipment 176b/07 Incorporating the units: SPF0702480 SPF0724851 CFP704-4 Switch mode power supply unit board 2 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Four zone conventional control and indicating equipment 176b/08 Incorporating the units: SPF0702480 SPF0724853 CFP708-4 Switch mode power supply unit board 4 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment 176b/09 Incorporating the units: SPF0702480 SPF0724855 CFP702-4/ACNL Switch mode power supply unit board 8 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Two zone conventional control and indicating equipment 176b/10 Incorporating the following units: SPF0702480 SPF0724837 CFP704-4/ACNL Switch mode power supply unit board 2 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 7.13 Alarm counter 10 Test condition Four zone conventional control and indicating equipment 176b/11 Incorporating the following units: SPF0702480 SPF0724839 Switch mode power supply unit board 4 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 32 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products CFP708-4/ACNL LPCB Ref. No. 7.11 Delays to outputs 7.13 Alarm counter 10 Test condition Eight zone conventional control and indicating equipment 176b/12 Incorporating the following units: SPF0702480 SPF0724841 Switch mode power supply unit board 8 Zone main control board CFP702-2 Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 7.13 Alarm counter 10 Test condition Alarmsense two zone conventional control and indication equipment 176b/14 CFP704-2 Incorporating the following units: SPF0702480 Switch mode power supply unit board SPF0724851 2 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Alarmsense four zone conventional control and indicating equipment 176b/15 CFP708-2 Incorporating the following units: SPF0702480 Switch mode power supply unit board SPF0724853 4 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Alarmsense eight zone conventional control and indicating equipment 176b/16 CFP702E-4 CFP704E-4 CFP708E-4 Incorporating the following units: SPF0702480 Switch mode power supply unit board SPF0724855 8 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Two zone conventional control and indicating equipment Incorporating the units: SPF0702480 Switch mode power supply unit board SPF0724851 2 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs Four zone conventional control and indicating equipment Incorporating the units: SPF0702480 Switch mode power supply unit board SPF0724853 4 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs Eight zone conventional control and indicating equipment Incorporating the units: SPF0702480 Switch mode power supply unit board SPF0724855 8 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 176b/17 176b/18 176b/19 Certificate No: 176c to EN 12094-1: 2003 and EN 54-2: 1997 + A1: 2006 + A2: 2007, EN 54-4: 1997 + A1: 2002 + A2: 2006 20 Oct 2014 33 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products EP203 Conventional three zone class A extinguisher control panel LPCB Ref. No. 176c/01 Incorporating the following units: SPF0000203 SPF0000212 SPF0003613 SPF0000214 Main extinguisher control External relay interface Power supply unit EP214 terminator Incorporating as modular units: EP210S EP211 Remote Status Unit Surface Mount optional (See Note 1) Economy Status Unit optional (See Note 1) Certified with the following options with requirements from EN 12094-1:2003 4.17 Delay of extinguishing signal 4.18 Signal representing the flow of extinguishing agent 4.19 Monitoring of the status of components 4.20 Emergency hold device 4.21 Control of flooding time 4.23 Manual only mode 4.26 Triggering of equipment outside the system 4.27 Emergency abort device 4.30 Activation of alarm devices with different signals Certified with the following options with requirements from EN-54-2:1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.13 Alarm counter 10 Test condition Notes: 1. Optional Remote Status Unit part No. EP210S & Economy Status Unit part No. EP211 are not certified as meeting the requirements of the standards specified. 2. EP203/CON Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature range of -5°C to +40°C. Conventional three zone class A extinguisher control panel under Context Plus Brand 176c/01 Incorporating the following units: SPF0000203 SPF0000212 SPF0003613 SPF0000214 Main extinguisher control External relay interface Power supply unit EP214 terminator Incorporating as modular units: EP210S EP211 Remote Status Unit Surface Mount optional (See Note 1) Economy Status Unit optional (See Note 1) Certified with the following options with requirements from EN 12094-1:2003 4.17 Delay of extinguishing signal 4.18 Signal representing the flow of extinguishing agent 4.19 Monitoring of the status of components 4.20 Emergency hold device 4.21 Control of flooding time 4.23 Manual only mode 4.26 Triggering of equipment outside the system 4.27 Emergency abort device 4.30 Activation of alarm devices with different signals Certified with the following options with requirements from EN-54-2:1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.13 Alarm counter 10 Test condition Notes: 1. Optional Remote Status Unit part No. EP210S & Economy Status Unit part No. EP211 are not certified as meeting the requirements of the standards specified. 2. Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature 34 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products EP203/DE LPCB Ref. No. range of -5°C to +40°C. Conventional three zone class A extinguisher control panel German Language Variant 176c/01 Incorporating the following units: SPF0000203 SPF0000212 SPF0003613 SPF0000214 Main extinguisher control External relay interface Power supply unit EP214 terminator Incorporating as modular units: EP210S EP211 Remote Status Unit Surface Mount optional (See Note 1) Economy Status Unit optional (See Note 1) Certified with the following options with requirements from EN 12094-1:2003 4.17 Delay of extinguishing signal 4.18 Signal representing the flow of extinguishing agent 4.19 Monitoring of the status of components 4.20 Emergency hold device 4.21 Control of flooding time 4.23 Manual only mode 4.26 Triggering of equipment outside the system 4.27 Emergency abort device 4.30 Activation of alarm devices with different signals Certified with the following options with requirements from EN-54-2:1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.13 Alarm counter 10 Test condition Notes: 1. Optional Remote Status Unit part No. EP210S & Economy Status Unit part No. EP211 are not certified as meeting the requirements of the standards specified. 2. Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature range of -5°C to +40°C. Context Plus Ltd Export House, 175 Mauldeth Road, Fallowfield, Manchester M14 6SG, United Kingdom Tel: +44 (0)161 257 2541 • Fax: +44 (0)161 225 8817 E-mail: [email protected] • Website: www.xportsales.com Certificate No: 176b-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1 :2002 + A2:2006 Certificate No: 176c-(cl-2) to EN 54-2: 1997 + A1: 2006 Control and indicating equipment Certificated Products XFP502/X/CON Two Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo Protocol, Metal housing LPCB Ref. No. 176b/02 Incorporating the following units: SPF0501000 SPF0501201 SPF0501200 Switch mode power supply board XFP Apollo 2 Loop, Main motherboard Display board Keypad Display Certified with the following options with requirements from EN 54-2:1997 7.8 7.11 7.12.1 20 Oct 2014 Output to fire alarm device(s) Delays to the actioning of outputs fire alarm devices and fire routing equipment Dependencies on more than one alarm signal - Type A 35 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products XFP501/X/CON LPCB Ref. No. 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Note : 1. Scope of approval does not include the operation of the network functionality. One Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo Protocol, Metal housing 176b/04 Incorporating the following units: SPF0501000 SPF0501211 SPF0501200 Switch mode power supply board XFP Apollo 1 Loop, Main motherboard Display board Keypad Display Certified with the following options with requirements from EN 54-2:1997 7.8 7.11 XFP501E/X/CON Output to fire alarm device(s) Delays to the actioning of outputs fire alarm devices and fire routing equipment Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Alarm counter Fault signals from points Disablement of each address point Test condition 7.12.1 7.12.2 7.12.3 7.13 8.3 9.5 10 Note: 1. Scope of approval does not include the operation of the network functionality. One Loop, 16 Zone Analogue addressable control and indicating equipment using Apollo protocol, Plastic housing 176b/06 Incorporating the following units: SPF0702480 SPF0501101 Switch mode power supply board XFP Apollo 1 Loop, Main motherboard Certified with the following options with requirements from EN 54-2:1997 7.8 7.11 CFP702-4/CON Output to fire alarm device(s) Delays to the actioning of outputs fire alarm devices and fire routing equipment Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Alarm counter Fault signals from points Disablement of each address point Test condition 7.12.1 7.12.2 7.12.3 7.13 8.3 9.5 10 Note: 1. Scope of approval does not include the operation of the network functionality. Two zone conventional control and indicating equipment 176b/07 Incorporating the units: SPF0702480 Switch mode power supply unit board SPF0724851 2 Zone main control board CFP704-4/CON Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Four zone conventional control and indicating equipment 176b/08 Incorporating the units: SPF0702480 Switch mode power supply unit board SPF0724853 4 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 36 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products CFP708-4/CON LPCB Ref. No. 10 Test condition Eight zone conventional control and indicating equipment 176b/09 Incorporating the units: SPF0702480 SPF0724855 Switch mode power supply unit board 8 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 EP203/CON 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Conventional three zone class A extinguisher control panel under Context Plus Brand 176c/01 Incorporating the following units: SPF0000203 SPF0000212 SPF0003613 SPF0000214 Main extinguisher control External relay interface Power supply unit EP214 terminator Incorporating as modular units: EP210S EP211 Remote Status Unit Surface Mount optional (See Note 1) Economy Status Unit optional (See Note 1) Certified with the following options with requirements from EN 12094-1:2003 4.17 4.18 4.19 4.20 4.21 4.23 4.26 4.27 4.30 Delay of extinguishing signal Signal representing the flow of extinguishing agent Monitoring of the status of components Emergency hold device Control of flooding time Manual only mode Triggering of equipment outside the system Emergency abort device Activation of alarm devices with different signals Certified with the following options with requirements from EN 54-2:1997 7.8 7.11 Output to fire alarm device(s) Delays to the auctioning of outputs fire alarm devices and fire routing equipment Alarm counter Test condition 7.13 10 Note: 1. Optional Remote Status Unit part No. EP210S & Economy Status Unit part No. EP211 are not certified meeting the requirements of the standards specified 2. Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature range of -5°C to +40°C. Control Equipment Limited Hillcrest Business Park, Dudley, West Midlands DY2 9AP, United Kingdom Tel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972 E-mail: [email protected] • Website: www.controlequipment.com Certificate No: 018c to EN 54: Part 2 and 4: 1997 Certificate No: 681af-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 681ag-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 20 Oct 2014 37 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Control and indicating equipment Certificated Products Discovery Precept En2 (2605-100) Precept En4 (2605-101) Precept En8 (2605-102) Precept En16 (2605-103) Precept En32 (2605-104) 38 4 loop analogue addressable control and indicating equipment Incorporating: A1579 Motherboard A1580 Display board A1585 Loop cards A1584 230 Vac power supply control card A1599 Printer board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 2 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 4 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 16 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board C1629 Display board C1631 Repeater interface board (option) C1632 16 Zone Expansion board C1652 5A Power supply board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment LPCB Ref. No. 018c/01 018c/02 018c/03 018c/04 018c/05 018c/06 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products Precept En8 (2605-110) Precept En16 Repeater (2605-111) Precept En32 Repeater (2605-112) 508.031.701 LPCB Ref. No. 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 16 zone conventional repeater unit Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 32 zone conventional repeater unit Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition FIRE CLASS Duo-CEL, 1 zone conventional control and indicating equipment 018c/R01 018c/R02 018c/R03 681af/01 Incorporating as modular units: C1694 - 2605501, 1 Zone Motherboard BAQ-35T24 Power Supply 508.031.702 Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition FIRE CLASS Duo-CEL, 2 zone conventional control and indicating equipment 681af/02 Incorporating as modular units: C1694 - 2605502, 2 Zone Motherboard BAQ-35T24 Power Supply 508.031.703 Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition FIRE CLASS Duo-CEL, 4 zone conventional control and indicating equipment 681af/03 Incorporating as modular units: C1694 - 2605503 4 Zone Motherboard BAQ-35T24 Power Supply Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 20 Oct 2014 39 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products 508.031.704 LPCB Ref. No. 7.13 Alarm counter 10 Test condition FIRE CLASS Duo-CEL, 8 zone conventional control and indicating equipment 681af/04 Incorporating as modular units: C1694 - 2605504, 8 Zone Motherboard BAQ-35T24 Power Supply 508.031.705 Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition FIRE CLASS Duo-CEL, Fire alarm repeater (mains). 681af/R01 508.031.706 Incorporating as modular units: C1694 2605505, Repeater Motherboard BAQ-35T24 Power Supply Note: Compatible with 2605543 & 2605544 panels only. FIRE CLASS Duo-CEL, Fire alarm repeater (24 VDC). 681af/R02 Incorporating as a modular unit: C1694 2605506, Repeater Motherboard Note: Compatible with 2605543 & 2605544 panels only. FC32-1 FIRECLASS 557.200.701 analogue addressable control and indicating equipment 1 loop, 32 Zone Incorporating as modular units: DCM832R Operator Control / Display Module CPU800 Main CPU module FIM801 Field Interface Module PMM800 Power Supply Monitor BAQ60T24 Power Supply 681ag/01 Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Note: 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. FC64-2 FIRECLASS (557.200.702) analogue addressable control and indicating equipment 2 loop, 64 Zone Incorporating as modular units: DCM864R Operator Control / Display Module CPU800 Main CPU module FIM802 Field Interface Module PMM800 Power Supply Monitor BAQ140T24 Power Supply 681ag/02 and as optional modular units: IOB800 Input/Output Expansion Board Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 40 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products FC64-4 FC240-2 20 Oct 2014 LPCB Ref. No. 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. FIRECLASS (557.200.703) analogue addressable control and indicating equipment 4 loop, 64 Zone Incorporating as modular units: DCM864R Operator Control / Display Module CPU800 Main CPU module FIM802 Field Interface Module PMM800 Power Supply Monitor BAQ140T24 Power Supply PMM840 Power Supply Monitor XLM800 Loop Expander Board and as optional modular units: IOB800 Input/Output Expansion Board Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Note: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. FIRECLASS (557.200.704) analogue addressable control and indicating equipment 2 loop, 240 Zone Incorporating as modular units: DCM832 Operator Control / Display Module CPU800 Main CPU module FIM802 Field Interface Module PMM800 Power Supply Monitor BAQ140T24 Power Supply and as optional modular units: IOB800 Input/Output Expansion Board Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 681ag/03 681ag/04 41 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.12.1 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 11 Note: Dependencies on more than one alarm signal (Type A dependency) Dependencies on more than one alarm signal (Type B dependency) Dependencies on more than one alarm signal (Type C dependency) Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition Standardized input/output interface 1) FC240-4 557.200.706 This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. FIRECLASS (557.200.705) analogue addressable control and indicating equipment 4 loop, 240 Zone Incorporating as modular units: DCM832 Operator Control / Display Module CPU800 Main CPU module FIM802 Field Interface Module PMM800 Power Supply Monitor BAQ140T24 Power Supply PMM840 Power Supply Monitor XLM800 Loop Expander Board and as optional modular units: IOB800 Input/Output Expansion Board Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Note: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. FIRE CLASS 32 RA, 32 Zone Repeater Panel, is approved for use with the 557.200.701 Fire Class 32-1 control and indicating equipment. Incorporating as modular units: 681ag/05 681ag/R01 557.200.707 DCM832R Operator Control / Display Module PMM800 Power Supply Monitor BAQ60T24 Power Supply FIRE CLASS 64 RA, 64 Zone Repeater Panel, is approved for use with the 557.200.702 Fire Class 64-2 and 557.200.703 Fire Class 64-4 control and indicating equipment. Incorporating as modular units: 681ag/R02 557.200.708 DCM864R Operator Control / Display Module PMM800 Power Supply Monitor BAQ60T24 Power Supply FIRE CLASS 240 RA, 240 Zone Repeater Panel, is approved for use with the 557.200.704 Fire Class 240-2 and 557.200.705 Fire Class 240-4 control and indicating equipment. Incorporating as modular units: 681ag/R03 DCM832 PMM800 BAQ60T24 42 Operator Control / Display Module Power Supply Monitor Power Supply 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificate No: 681ad-(cl-1) to EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 681ac-(cl-1) to EN 54-4: 1997 + A1: 2002 + A2: 2006 Power Supply Unit Certificated Products PSU A17 PSU A38 557.200.732 557.200.733 557.200.731 Addressable 17Ah Power Supply Unit Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels 2. The maximum lead length for the fault output connection is 3m Addressable 38Ah Power Supply Unit Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels 2. The maximum lead length for the fault output connection is 3m PSU A17 Addressable 17Ah Power Supply Unit Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels 2. The maximum lead length for the fault output connection is 3m PSU A38 Addressable 38Ah Power Supply Unit Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels 2. The maximum lead length for the fault output connection is 3m FIRE CLASS 1.9A Power Supply Unit Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels LPCB Ref. No. 681ac/01 681ac/02 681ad/01 681ad/02 681ad/03 Certificate No: 018a to BS 5839: Part 4. This certificate is to a withdrawn standard. Control and indicating equipment conforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because control and indicating equipment meeting the withdrawn standard is still requested by some regulators outside of the EU. Control and indicating equipment Certificated Products Precept Precept Precept Precept 20 Oct 2014 2 zone control and indicating equipment Incorporating as modular units C1423 Motherboard C1440 Display Board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 4 zone control and indicating equipment Incorporating as modular units C1423 Motherboard C1441 Display Board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 8 zone control and indicating equipment Incorporating as modular units C1427 Motherboard C1462 Display Board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 16 zone control and indicating equipment Incorporating as modular units C1425 Motherboard C1426 Display Board LPCB Ref. No. 018a/01 018a/02 018a/03 018a/04 43 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products Precept Series 600 Series 600 Series 600 Series 600 Series 600 44 LPCB Ref. No. Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 32 zone control and indicating equipment Incorporating as modular units C1425 Motherboard C1426 Display Board C1464 Display Board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 2 zone control and indicating equipment Incorporating as modular units C1423 Motherboard C1440 Display Board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 4 zone control and indicating equipment Incorporating as modular units C1423 Motherboard C1441 Display Board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 8 zone control and indicating equipment Incorporating as modular units C1427 Motherboard C1462 Display Board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 16 zone control and indicating equipment Incorporating as modular units C1425 Motherboard C1426 Display Board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 32 zone control and indicating equipment Incorporating as modular units C1425 Motherboard C1426 Display Board C1464 Display Board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 018a/05 018a/06 018a/07 018a/08 018a/09 018a/10 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Cooper Industries Inc Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom Tel: +44 (0)1302 303303 • Fax: +44 (0)1302 367155 E-mail: [email protected] • Website: www.cooper-ls.com UK Sales: Menvier & JSB Tel: +44 (0)1302 303202 • Fax: +44 (0)1302 367155 E-mail: [email protected] • Website: www.cooper-ls.com UK Sales: Tel: +44 (0)1594 541900 • Fax: +44 (0)1594 541910 E-mail: [email protected] • Website: www.cooperfire.co.uk Certificate No: 714a to EN 54 Part 2 and 4 :1997 Certificated Products CF3000 DF6000 20 Oct 2014 Analogue addressable 2 and 4 loop Control and indicating equipment Incorporating the following units: ADF6 Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop card (2 off) ADF6 Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Analogue addressable 2 and 4 loop control and indicating equipment Incorporating the following units: ADF6 Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop card (2 off) ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment LPCB Ref. No. 714a/01 714a/01 45 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.10 7.11 FX6000 CF2000 Output to automatic fire protection equipment Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Analogue addressable 2 and 4 Loop control and indicating equipment Incorporating the following units: ADF6 Back Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop Card (2 off) ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6 DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Analogue addressable 2 Loop control and indicating equipment Incorporating the following units: PR202-50-2209 Power supply board PR202-50-2206 Main motherboard PR202-50-2205 Display board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition 714a/01 714a/02 Cooper Lighting and Safety Ltd Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom Tel: +44 (0)1302 303397 • Fax: +44 (0)1302 303251 Website: www.cooper-Is.com Certificate No: 714h to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 714p to EN 54-2:1197+ A1:2006 and EN 54-4:1997+A1:2002+A2:2006 Certificate No: 714n to EN 54-16:2008 Certificated Products CF3000 Intelligent analogue addressable 2 and 4 loop control and indicating equipment LPCB Ref. No. 714h/01 Incorporating the following units: 46 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. ADF6 Back YPCB2153 YPCB2147 YPCB2148 ADF6Screen YPCB2185 ADF6 DISPCOVER ADF6FACIA ADF6PRINTDOOR BAT-NP12-12 ADF6HINGE ADF6OPFACIA ADF6PRINTER YPCB2187 Assembled back box Motherboard PCB PSU PCB 2 Loop Card (2 off) Touch Screen Complete Display + Micro PCB Display PCB Cover Front Moulding Printer Door Moulding Batteries (2 off) Door Hinges Optional Anti Tamper Cover Printer Fire Brigade Interface Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment (Type A) 7.10.2 Output to automatic fire protection equipment (Type B) 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal (Type C) 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Notes: 1. 2. DF6000 The scope of approval does not include the network functionality. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Intelligent analogue addressable 2 and 4 loop control and indicating equipment 714h/01 Incorporating the following units: ADF6 Back YPCB2153 YPCB2147 YPCB2148 ADF6Screen YPCB2185 ADF6 DISPCOVER ADF6FACIA ADF6PRINTDOOR BAT-NP12-12 ADF6HINGE ADF6OPFACIA ADF6PRINTER YPCB2187 Assembled back box Motherboard PCB PSU PCB 2 Loop Card (2 off) Touch Screen Complete Display + Micro PCB Display PCB Cover Front Moulding Printer Door Moulding Batteries (2 off) Door Hinges Optional Anti Tamper Cover Printer Fire Brigade Interface Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment (Type A) 7.10.2 Output to automatic fire protection equipment (Type B) 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal (Type C) 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Notes: 1. 2. CF2000 20 Oct 2014 The scope of approval does not include the network functionality. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Analogue addressable 2 loop control and indicating equipment 714h/02 47 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating the following units: PR202-50-2209 Power supply board PR202-50-2206 Main motherboard PR202-50-2205 Display board Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment (Type A) 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal (Type C) 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Notes: 1. 2. VoCall The scope of approval does not include the network functionality. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. CFVADAU100 100W Single channel addressable DAU with EMA Emergency microphone 714n/01 VoCALL DAU Unit consisting of: VoCALL Voice DAU Controller rev 2 (YPCB2387) VoCALL Voice DAU Base Board rev 4 (YPCB2386) Audio Safe Module rev 3 (YPCB2353) DF6000 PSU (YPCB2147CPD) Cooper PAVA Loop to Voice rev 1(YPCB2345) VoCALL Voice DAU 100V line connector rev0 (YPCB2389) VoCALL Voice LSA 50/100 Amplifier (YPCB2388) VoCALL EMA Emergency microphone unit consisting of: VoCALL Voice FMA rev 1 VoCALL Voice FMA Display rev 0 (YPCB2390) Certified with the following options with requirements from EN 54-16 7.6.2 Manual silencing of the voice alarm condition 7.7.2 Manual rest of the voice alarm condition 8.3 Indication of faults related to the transmission path to the CIE 12.0 Emergency microphone(s) (applicable on EMA unit only CF5002 Two zone conventional control and indicating equipment 714p/01 Incorporating the units: PA-04-0244 Main control board with integrated power supply PA-04-0248 2 Zone display board CF5004 Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 10 Test condition Four zone conventional control and indicating equipment 714p/02 Incorporating the units: PA-04-0245 Main control board with integrated power supply PA-04-0249 4 Zone display board CF5008 Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 10 Test condition Eight zone conventional control and indicating equipment 714p/03 Incorporating the units: PA-04-0246 Main control board with integrated power supply PA-04-0250 8 Zone display board Certified with the following options with requirements from EN 54-2: 1997 48 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products CF50016 LPCB Ref. No. 7.8 Output to fire alarm devices(s) 10 Test condition Sixteen zone conventional control and indicating equipment 714p/04 Incorporating the units: PA-04-0247 Main control board with integrated power supply PA-04-0251 16 Zone display board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 10 Test condition Detector Electronics Corporation 6901 West 110th Street, Minneapolis, Minesota 55438, USA Tel: +001 952 946 6488 E-mail: [email protected] • Website: www.det-tronics.com Certificate No: 973c to EN 54-2: 1997 + A1: 2006 Certificate No: 973d to EN 54-2: 1997 + A1: 2006 + EN12094-1: 2003 Certificated Products EQ5400D Single loop eight zone addressable control and indicating equipment IQ3150 Controller Detection panel EQ2220 (GFM) LTM EQ3730 (EDIO) LPCB Ref. No. 973c/01 Main controller Detection panel Ground Fault Monitor Lon termination module Enhanced Discrete Input/Output (SIL only) and as optional modular units: EQ3710 (AIM) EQ3720 (RM) Model EQ22EM (IDCSC) Model EQ25EM (SAM) Model EQ24EM (NE) Model EQ24EM (PLR) EQ3810 (PDM) 750XCXH-24D EQ5400R Analogue Input Module Relay Module Initiating Device Circuit - Short Circuit Signal Audible Module Network Extender Physical Layer Repeater Power Distribution Module Magnecraft relay module Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.13 Alarm counter 8.3 Fault signals from points 10 Test condition Single loop eight zone addressable control and indicating equipment 973c/02 Incorporating as modular units: EQ3150 Controller Detection panel Routing panel EQ2220 (GFM) LTM EQ3730 (EDIO) Main controller Detection panel Routing panel Ground Fault Monitor Lon termination module Enhanced Discrete Input/Output (SIL only) and as optional modular units: EQ3710 (AIM) EQ3720 (RM) Model EQ22EM (IDCSC) Model EQ25EM (SAM) 20 Oct 2014 Analogue Input Module Relay Module Initiating Device Circuit - Short Circuit Signal Audible Module 49 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Model EQ24EM (NE) Model EQ24EM (PLR) EQ3810 (PDM) 750XCXH-24D EQ5400E Network Extender Physical Layer Repeater Power Distribution Module Magnecraft relay module Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 10 Test condition Single loop eight zone addressable control and indicating equipment and two extinguishing zone class B electrical automatic control and delay devices 973d/01 Incorporating as modular units: EQ3150 Controller Detection panel Routing panel Extinguishing panel EQ2220 (GFM) EQ3LTM EQ3730 (EDIO) Main controller (Redundant) Detection panel Routing panel Extinguishing panel Ground Fault Monitor Lon termination module Enhanced Discrete Input/Output (SIL only) and as optional modular units: EQ3710 (AIM) EQ3720 (RM) Model EQ22EM (IDCSC) Model EQ25EM (SAM) Model EQ24EM (NE) Model EQ24EM (PLR) EQ3810 (PDM) 750XCXH-24D Analogue Input Module Relay Module Initiating Device Circuit - Short Circuit Signal Audible Module Network Extender Physical Layer Repeater Power Distribution Module Magnecraft relay module Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition EQ5400G Certified with the following options with requirements from EN 12094-1: 4.17 Delay of extinguishing signal 4.18 Signal representing the flow of extinguishing agent 4.19 Monitoring of the status of components 4.20 Emergency hold device 4.21 Control of flooding time 4.23 Manual only mode 4.24 Triggering signals to equipment within the system 4.26 Triggering of equipment outside the system Single loop eight zones Addressable control and indicating equipment and two extinguishing zone class B electrical automatic control and delay devices. 973d/02 Incorporating as modular units: EQ3150 Controller Detection panel Extinguishing panel EQ2220 (GFM) 50 Main controller (Redundant) Detection panel Extinguishing panel Ground Fault Monitor 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. EQ3LTM EQ3730 (EDIO) Lon termination module Enhanced Discrete Input/Output (SIL only) and as optional modular units: EQ3710 (AIM) EQ3720 (RM) Model EQ22EM (IDCSC) Model EQ25EM (SAM) Model EQ24EM (NE) Model EQ24EM (PLR) EQ3810 (PDM) 750XCXH-24D Analogue Input Module Relay Module Initiating Device Circuit - Short Circuit Signal Audible Module Network Extender Physical Layer Repeater Power Distribution Module Magnecraft relay module Certified with the following options with requirements from EN 54 Part 2: 7.8 7.10.1 7.10.2 7.10.3 7.10.4 7.12.2 7.13 8.3 8.4 10 Output to fire alarm devices Outputs to fire protection equipment (Type A) Outputs to fire protection equipment (Type B) Outputs to fire protection equipment (Type C) Fault monitoring of fire protection equipment Dependencies on more than one alarm signal (Type B dependency) Alarm counter Fault signals from points Total loss of the power supply Test condition Certified with the following options with requirements from EN 12094-1: 4.17 4.18 4.19 4.20 4.21 4.23 4.24 4.26 Delay of extinguishing signal Signal representing the flow of extinguishing agent Monitoring of the status of components Emergency hold device Control of flooding time Manual only mode Triggering signals to equipment within the system Triggering of equipment outside the system Emirates Fire Protections Equip. Factory. TR. Section Behind the Fourth Industrial Estate, Industrial Area 3, UAE PO 22436, Sharjah, United Arab Emirates Tel: 00971 653 40300 • Fax: 00971 653 40090 E-mail: [email protected] • Website: www.firexuae.com Certificate No: 548p-(cl-5) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Control and indicating equipment Certificated Products FX200-2 Intelligent 2 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment Incorporating the following units: MB-220/ F7.820.826 SB-220/ F7.820.827 TB-220/ F7.820.828 PS-220/ F7.820.829b ZP-220/ F7.820.312d LC200/ F7.820.1125 LPCB Ref. No. 548p/01 Main board Switch board Loop interface board Power supply unit Zone indication and intervention board Loop board Incorporating as optional modular units: FX9930/ F7.820.913a RS-232 board for configuration FX9901A Printer module kit Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 20 Oct 2014 51 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products FX-IFP8 LPCB Ref. No. 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment 548p/02 Incorporating the following units: SB-800/ F7.820.1238 Indication board LCIFP8/ F7.820.1239 Loop board PB-800/ F7.820.1311 Power board ZP-800/ F7.820.1312 ZCP board KB-800/ F7.820.1326 Keypad board MB-800/ F7.820.1237 Main board MO-800/ F7.820.1310 Mother board Incorporating as optional modular units: P-9935/ F7.820.1313 USB communication board Optional language variants: 10104673 Portuguese language variant 10104675 Hungarian language variant Certified with the following options with requirements from EN 54 Part 2: FX102A 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.9.2 Alarm confirmation input from fire routing equipment 7.10.1 Output type A 7.10.2 Output type B 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition 2 Zone conventional control and indicating equipment 548p/03 Incorporating the following modules: FC-102A/ F7.843.399 Membrane CB-102A/ F2.908.1719 Control board with integrated PSE DB-102A/ F2.908.1722 Display board FX104A Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 4 Zone conventional control and indicating equipment 548p/04 Incorporating the following modules: FC-104A/ F7.843.400 Membrane CB-104A/ F2.908.1718 Control board with integrated PSE DB-104A/ F2.908.1721 Display board Optional modules: 10104649 Traditional Chinese text variant CF-104A/ F7.843.422 Membrane FX108A Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 8 Zone conventional control and indicating equipment 548p/05 Incorporating the following modules: FC-108A/ F7.843.401 Membrane CB-108A/ F2.908.1675 Control board with integrated PSE DB-108A/ F2.908.1720 Display board Optional modules: 10104650 Traditional Chinese text variant 52 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. CF-108A/ F7.843.423 FX116A Membrane Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 16 Zone conventional control and indicating equipment 548p/06 Incorporating the following modules: FC-116A/ F7.843.402 Membrane XB-116A/ F2.908.1724 Control board with integrated PSE DB-116A/ F2.908.1676 Display board CB-116A/ F7.820.1677 Expansion board Optional modules: 10104651 Traditional Chinese text variant CF-116A/ F7.843.424 Membrane FX200-2/1 Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment Incorporating the following units: MB-220/ F7.820.826 SB-220/ F7.820.827 TB-220/ F7.820.828 PS-220/ F7.820.829b ZP-220/ F7.820.312d 548P/08 Main board Switch board Loop interface board Power supply unit Zone indication and intervention board Incorporating as optional modular units: FX9930/ F7.820.913a RS-232 board for configuration FX9901A Printer module kit LC200/ F7.820.1125 Loop board (for loop expansion) Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Eurotech Fire Systems Limited 19/20 Stratfield Park, Elettra Avenue, Waterlooville, Hampshire PO7 7XN, United Kingdom Tel: +44 (0)203 141 0999 • Fax: +44 (0)239 225 2554 E-mail: [email protected] • Website: www.eurotechfire.com Certificate No: 1213b to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 and EN 54-4: 1998 + A1: 2002 + A2: Certificate No: 1213a to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 and EN 54-4: 1998 + A1: 2002 + A2: 2006 Control and indicating equipment Certificated Products 510-0108A Odyssey Plus One loop, 32 Zone analogue addressable control and indicating equipment. LPCB Ref. No. 1213b/01 Incorporating as modular units: BRD68BPSC4-A FFP Brigade & Power supply control board (8610) BRD86DLTB4-A FFP Dual loop termination board (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) 20 Oct 2014 53 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 510-0208A Odyssey Plus BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610) Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Two loop, 32 Zone analogue addressable control and indicating equipment. 1213b/02 510-0308A Odyssey Plus Incorporating as modular units: BRD68BPSC4-A FFP Brigade & Power supply control board (8610) BRD86DLTB4-A FFP Dual loop termination board (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86SCB3-A FFP Slave CPU card (8610) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610) Optional Modules: BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Three loop, 32 Zone analogue addressable control and indicating equipment 1213b/03 Incorporating as modular units: BRD68BPSC4-A FFP Brigade & Power supply control board (8610) BRD86DLTB4-A FFP Two Dual loop termination boards (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86SCB3-A FFP Two Slave CPU cards (8610) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610) Optional Modules: BRD86DLTB4-A FFP Dual loop termination board (8610) BRD86SCB3-A FFP Slave CPU cards (8610) BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Incorporating as modular units: 54 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products 510-0408A Odyssey Plus LPCB Ref. No. BRD68BPSC4-A FFP Brigade & Power supply control board (8610) BRD86DLTB4-A FFP Two Dual loop termination boards (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86SCB3-A FFP Two Slave CPU cards (8610) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610) Optional Modules: BRD86DLTB4-A FFP Dual loop termination board (8610) BRD86SCB3-A FFP Slave CPU cards (8610) BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Four loop, 32 Zone analogue addressable control and indicating equipment 1213b/04 Incorporating as modular units: BRD68BPSC4-A FFP Brigade & Power supply control board (8610) BRD86DLTB4-A FFP Two Dual loop termination boards (8610) BRD86FPB5-B FFP Front panel board EN54 (8610) BRD86MBA4-A FFP Main board LCD (8610) BRD86MCPU4-B FFP Main 64MB CPU card (8610) BRD86SCB3-A FFP Three Slave CPU cards (8610) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) PSU1888 Power supply 5A (8610) Optional Modules: BRD86DLTB4-A FFP Dual loop termination board (8610) BRD86SCB3-A FFP Slave CPU cards (8610) BRD43EZC2-A 8 Zone conventional module (4310) BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routine equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Fike Safety Technology Ltd Unit 31, Springvale Industrial Estate, Cwmbran, Gwent NP44 5BD, United Kingdom Tel: +44 (0)1633 865558 • Fax: +44 (0)1633 866656 E-mail: [email protected] • Website: www.fikesafetytechnology.co.uk Certificate No: 331q to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products 507-0001 Quadnet, 4 loop analogue addressable control and indicating equipment LPCB Ref. No. 331q/01 Incorporating the following units: 20 Oct 2014 55 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 10-0049 10-0050 SP14Q006-T 10-0051 10-0058 10-0053 Main CIE Board LED Board LCD Module Backplane Loop Card PSU Interface Certified with the following options with requirements from EN54-2: 7.8 7.10.1 7.11 7.12.2 8.3 8.9 9.5 10 Note: 1. 507-0009 Output to fire alarm devices Output to fire protection equipment - Type A Delays to outputs Dependencies on more than one alarm signal - Type B Fault signals from points Fault warning routing equipment Disablement of each addressable point Test condition This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13 Quadnet, 4 loop analogue addressable control and indicating equipment with printer 331q/02 Incorporating the following units: 10-0049 Main CIE Board 10-0050 LED Board SP14Q006-T LCD Module 10-0051 Backplane 10-0058 Loop Card 10-0053 PSU Interface 21-0005 Printer Certified with the following options with requirements from EN54-2: 7.8 7.10.1 7.11 7.12.2 8.3 8.9 9.5 10 Note: 1. 510-0001 Output to fire alarm devices Output to fire protection equipment - Type A Delays to outputs Dependencies on more than one alarm signal - Type B Fault signals from points Fault warning routing equipment Disablement of each addressable point Test condition This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13 Duonet, 2 loop analogue addressable control and indicating equipment 331q/04 Incorporating the following units: 10-0049 Main CIE Board 10-0050 LED Board SP14Q006-T LCD Module 10-0069 Backplane 10-0058 Loop Card 10-0053 PSU Interface Certified with the following options with requirements from EN54-2: 7.8 7.10.1 7.11 7.12.2 8.3 8.9 9.5 10 Note: 1. 510-0003 56 Output to fire alarm devices Output to fire protection equipment - Type A Delays to outputs Dependencies on more than one alarm signal - Type B Fault signals from points Fault warning routing equipment Disablement of each addressable point Test condition This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13 Duonet, 2 loop analogue addressable control and indicating equipment with printer 331q/05 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating the following units: 10-0049 Main CIE Board 10-0050 LED Board SP14Q006-T LCD Module 10-0069 Backplane 10-0058 Loop Card 10-0053 PSU Interface 21-0005 Printer Certified with the following options with requirements from EN54-2: 7.8 7.10.1 7.11 7.12.2 8.3 8.9 9.5 10 Note: 1. 505-0002 Output to fire alarm devices Output to fire protection equipment - Type A Delays to outputs Dependencies on more than one alarm signal - Type B Fault signals from points Fault warning routing equipment Disablement of each addressable point Test condition This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13 TWINFLEXpro, 2 Zone conventional control and indicating equipment 331q/06 Incorporating: 10-0067 Main Processor Card. Certified with the following options from EN 54 Part 2: 505-0004 7.8 Output to fire alarm devices 7.10.1 Output type A to fire protection equipment 7.11 Delays to outputs 7.12.1 Type A dependency on more than one alarm signal 8.3 Fault signals from points 10 Test condition. TWINFLEXpro, 4 Zone conventional control and indicating equipment 331q/07 Incorporating: 10-0067 Main Processor Card. Certified with the following options from EN 54 Part 2: 505-0008 7.8 Output to fire alarm devices 7.10.1 Output type A to fire protection equipment 7.11 Delays to outputs 7.12.1 Type A dependency on more than one alarm signal 8.3 Fault signals from points 10 Test condition. TWINFLEXpro, 8 Zone conventional control and indicating equipment 331q/08 Incorporating: 10-0067 Main Processor Card 10-0087 4 Zone expansion card. Certified with the following options from EN 54 Part 2: 7.8 7.10.1 7.11 7.12.1 8.3 10 20 Oct 2014 Output to fire alarm devices Output type A to fire protection equipment Delays to outputs Type A dependency on more than one alarm signal Fault signals from points Test condition. 57 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Firelite by Honeywell (Pittway Systems Technology Group (Europe) Ltd) Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 1444 230 300 • Fax: +44 1444 230 888 E-mail: [email protected] Certificate No: 154g to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products FLS2-8 2 Zone FLS2-8 4 Zone FLS2-8 8 Zone 002-475-122 Language region 1, light grey 002-489-122 Language region 1, light grey, English manual 002-475-222 Language region 2, light grey 002-489-222 Language region 2, light grey, English manual Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition 002-475-142 Language region 1, light grey 002-489-142 Language region 1, light grey, English manual 002-475-242 Language region 2, light grey 002-489-242 Language region 2, light grey, English manual Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition 002-475-182 Language region 1, light grey 002-489-182 Language region 1, light grey, English manual 002-475-282 Language region 2, light grey 002-489-282 Language region 2, light grey, English manual LPCB Ref. No. 154g/06 154g/07 154g/08 Incorporating the following units: 020-747 8-way relay kit 020-772 4-way monitored sounder kit Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition 58 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Firesafe 10 Sanderson Way, Marton, Blackpool FY4 4NB, United Kingdom Tel: 01253 699500 • Fax: 01253 699550 E-mail: [email protected] • Website: www.firesafe.co.uk Certificate No: 176b-(cl-1) to EN 54-2: 1997+A1: 2006 and EN 54-4: 1997+A1: 2002+A2: 2006 Certificated Products FXP502/X Two Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo Protocol, Metal housing LPCB Ref. No. 176b/02 Incorporating the following units: SPF0706000 SPF0501201 SPF0501200 Switch Mode Power supply board XFP Apollo 2 Loop, Main motherboard Display board Keypad Display Certified with the following options with requirements from EN 54-2:1997 FXP501/X 7.8 Output to fire alarm device(s) 7.11 Delays to the auctioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. One Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo Protocol, Metal housing 176b/04 Incorporating the following units: SPF0706000 SPF0501211 SPF0501200 Switch Mode Power supply board XFP Apollo 1 Loop, Main motherboard Display board Keypad Display Certified with the following options with requirements from EN 54-2:1997 FXP501E/X 7.8 Output to fire alarm device(s) 7.11 Delays to the auctioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. One Loop, 16 Zone Analogue addressable control and indicating equipment using Apollo protocol, Plastic housing 176b/06 Incorporating the following units: SPF0702480 SPF0501101 Switch Mode Power supply board XFP Apollo 1 Loop, Main motherboard Certified with the following options with requirements from EN 54-2:1997 7.8 Output to fire alarm device(s) 7.11 Delays to the auctioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal Type A 20 Oct 2014 59 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products FCFP2N LPCB Ref. No. 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. Two zone conventional control and indicating equipment 176b/07 Incorporating the units: SPF0702480 SPF0724851 Switch mode power supply unit board 2 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 FCFP4N 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Four zone conventional control and indicating equipment 176b/08 Incorporating the units: SPF0702480 SPF0724853 Switch mode power supply unit board 4 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 FCFP8N 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment 176b/09 Incorporating the units: SPF0702480 SPF0724855 Switch mode power supply unit board 8 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 7.11 10 Output to fire alarm devices(s) Delays to outputs Test condition Gent By Honeywell (Novar Systems Ltd) 140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300 E-mail: [email protected] • Website: www.gent.co.uk Middle East Sales Enquiries E-mail: [email protected] Certificate No: 042x to EN 54: Parts 2 & 4: 1997 Certificate No: 042bb to EN 54-2: 1997 and EN 54-4: 1997 Certificate No: 042bm to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 and EN 54-16: 2008 Certificate No: 042bc to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products AS-2000 60 Two loop analogue addressable control and indicating equipment Incorporating as modular units: 2434-824 Power supply 2434-710 Loop Processor Card LPCB Ref. No. 042bb/01 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products Nano-24 LPCB Ref. No. 2434-833 Master Control Card 2434-825 Optical Network Card* 2434-821 Message Store Card* 2434-822 Mother board 2434-835 H.M.I 2434-840 Cold fire card 2434-796 Addressable speaker card (Optional Card)* 2434-826 Addressable daughter speaker card (Optional Card)* 2434-780 Audio Input Card (Optional Card)* 2434-781 Audio Output Card (Optional Card)* Scope of approval does not include the functionality of the network card and optional voice alarm system cards. Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Single loop analogue addressable control and indicating equipment Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface) 042bc/01 Nano-24-SP Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition Single loop analogue addressable control and indicating equipment (Spanish Language Variant) Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface) 042bc/02 Nano-24-PO Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition Single loop analogue addressable control and indicating equipment (Portuguese Language Variant) Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface) 042bc/03 Vigilon Compact-24-N Vigilon Compact-24-PO 20 Oct 2014 Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition Two loop analogue addressable control and indicating equipment (English language) Incorporating as modular units: 2434-859 Master Controller Board (MCB) 2434-862 Power Supply Unit 2434-762 Display and Key card (DKC) 2434-669 Loop processor card 4374-161 Text Membrane (English) 2434-861 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Two loop analogue addressable control and indicating equipment (Portuguese language variant) 042bc/04 042bc/05 61 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating as modular units: 2434-859 Master Controller Board (MCB) 2434-862 Power Supply Unit 2434-762 Display and Key card (DKC) 2434-669 Loop processor card 4374-163 Text Membrane (Portuguese) 2434-861 Copper network card (Note: Scope of approval does not include the operation of the network card) Vigilon Compact-24-SP Vigilon VIG1-24 Vigilon VIG1-24-NP Vigilon VIG1-24-PO 62 Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs Two loop analogue addressable control and indicating equipment (Spanish language variant) Incorporating as modular units: 2434-859 Master Controller Board (MCB) 2434-862 Power Supply Unit 2434-762 Display and Key card (DKC) 2434-669 Loop processor card 4374-162 Text Membrane (Spanish) 2434-861 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Four loop analogue addressable control and indicating equipment (English language) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer Module 4374-157 Text Membrane (English) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Four loop analogue addressable control and indicating equipment (English language variant without printer module) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 4374-157 Text Membrane (English) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Four loop analogue addressable control and indicating equipment (Portuguese language variant without printer module) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 042bc/06 042bc/07 042bc/08 042bc/09 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 4374-159 Text Membrane (Portuguese) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) Vigilon VIG1-24-SP Vigilon VIG1-72 Vigilon VIG1-72-PO 20 Oct 2014 Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Four loop analogue addressable control and indicating equipment (Spanish language variant without printer module) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer Module 4374-158 Text Membrane (Spanish) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Six loop analogue addressable control and indicating equipment (English Language) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-992 Thermistor board 2434-860 Battery terminal board 2434-832 Power supply PCB 2434-854 Backplane PCB 2434-761 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer module 4374-157 Text Membrane (English) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Six loop analogue addressable control and indicating equipment (Portuguese Language Variant without printer module) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-992 Thermistor board 2434-860 Battery terminal board 2434-832 Power supply PCB 2434-854 Backplane PCB 2434-761 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer module 4374-159 Text Membrane (Portuguese) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) 042bc/10 042bc/11 042bc/12 63 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products Vigilon VIG1-72-SP Compact VA LPCB Ref. No. Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Six loop analogue addressable control and indicating equipment (Spanish Language Variant without printer module) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-992 Thermistor board 2434-860 Battery terminal board 2434-832 Power supply PCB 2434-854 Backplane PCB 2434-761 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer module 4374-158 Text Membrane (Spanish) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Two loop voice alarm CIE with distributed mains powered amplifier 042bc/13 042bm/01 Incorporating as modular units within the Compact-VA: 2434-669LUGI Compact Loop Card 2434-859LUGI Compact Network Control Card 2434-862LUGI Compact Network PSU Card 2434-870LUGI Multiformat DKC Compact VA 2434-792 Audio Control Card 2434-023 MPEG Speech Card 2434-722 ACU DKC Card Incorporating as modular units within the Distributed Amplifier Unit: 2434-897LUGI Mains powered DAU PSU Card 2434-875 Mains Powered DAU Control Card 2434-876 Mains Powered DAU Amplifier 2434-880 MPEG Speech Card Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Certified with the following options with requirements from EN 54-16: 7.3 Audible warning 7.6.2 Manual silencing of the voice alarm condition 7.7.2 Manual reset of the voice alarm condition 7.8 Output to fire alarm devices 8.3 Indication of faults related to the transmission path to the CIE 8.4 Indication of faults related to voice alarm zones 12.0 Emergency microphones 13.14 Redundant power amplifiers Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 13270-01 64 1 zone conventional control and indicating equipment Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 042x/01 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products Xenex 1 13270-01LB 13270-02 Xenex 2 13270-02LB 13270-04 Xenex 4 13270-04LB 13270-08 Xenex 8 13270-08LB 1 zone conventional control and indicating equipment (Xenex brand) Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 2 zone conventional control and indicating equipment Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 2 zone conventional control and indicating equipment (Xenex brand) Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 4 zone conventional control and indicating equipment Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 4 zone conventional control and indicating equipment brand) Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 8 zone conventional control and indicating equipment Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 8 zone conventional control and indicating equipment (Xenex brand) Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition LPCB Ref. No. 042x/01 042x/02 042x/02 042x/03 042x/03 042x/04 042x/04 Gulf Security Technology Co., Ltd. No 80 Changjiang East Road, QETDZ, Qinhuangdao, Hebei Province 066004, China Tel: +86 0335 8502434 • Fax: +86 0335 8502532 E-mail: [email protected] • Website: www.gst.com.cn Sales Beijing: Tel: +86 (10) 6439 1866 • Fax: +86 (10) 6439 1787 Sales Hong Kong: Tel: +852 2877 8566 • Fax: +852 2511 8699 Certificate No: 548j to EN 54-2:1997, EN 54-4:1997 + A1: 2002 Control and indicating equipment Certificated Products GST-200 Intelligent 1 loop, 30 zone, analogue addressable control and indicating equipment Incorporating the following units: F7.820.826 F7.908.312 F7.820.827 20 Oct 2014 LPCB Ref. No. 548j/01 Main board Zone indication board Switch board 65 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. F7.820.828 F7.820.829 F2.910.093 R150 CGM12864 F2.828.630a GST 101 GST 102 GST 104 GST 108 GST 116 Loop interface board Power Supply unit Mains filter Transformer Alphanumeric Display Printer board (option) Incorporating as optional modular units: P-9901 Printer module kit F7.820.170 RS232 board for configuration Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10 Output to automatic Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points Single zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Two zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Four zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Sixteen zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition 548j/02 548j/03 548j/04 548j/08 548j/09 Certificate No: 548p to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products GST200-2 Intelligent 2 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment Incorporating the following units: MB-220/ F7.820.826 SB-220/ F7.820.827 TB-220/ F7.820.828 PS-220/ F7.820.829b ZP-220/ F7.820.312d LC200/ F7.820.1125 LPCB Ref. No. 548p/01 Main board Switch board Loop interface board Power supply unit Zone indication and intervention board Loop board Incorporating as optional modular units: P-9930/ F7.820.913a RS-232 board for configuration P-9901A Printer module kit GST-IFP8 Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment 548p/02 Incorporating the following units: 66 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. SB-800/ F7.820.1238 LCIFP8/ F7.820.1239 PB-800/ F7.820.1311 ZP-800/ F7.820.1312 KB-800/ F7.820.1326 MB-800/ F7.820.1237 MO-800/ F7.820.1310 Indication board Loop board Power board ZCP board Keypad board Main board Mother board Incorporating as optional modular units: P-9935/ F7.820.1313 USB communication board Optional language variants: 10104673 10104675 GST102A Portuguese language variant Hungarian language variant Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.9.2 Alarm confirmation input from fire routing equipment 7.10.1 Output type A 7.10.2 Output type B 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition 2 Zone conventional control and indicating equipment 548p/03 Incorporating the following modules: FC-102A/ F7.843.399 Membrane CB-102A/ F2.908.1719 Control board with integrated PSE DB-102A/ F2.908.1722 Display board Optional modules: 10104648 Traditional Chinese text variant CF-102A/ F7.843.421 Membrane GST104A Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 4 Zone conventional control and indicating equipment 548p/04 Incorporating the following modules: FC-104A/ F7.843.400 Membrane CB-104A/ F2.908.1718 Control board with integrated PSE DB-104A/ F2.908.1721 Display board Optional modules: 10104649 Traditional Chinese text variant CF-104A/ F7.843.422 Membrane GST108A Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 8 Zone conventional control and indicating equipment 548p/05 Incorporating the following modules: FC-108A/ F7.843.401 Membrane CB-108A/ F2.908.1675 Control board with integrated PSE DB-108A/ F2.908.1720 Display board 20 Oct 2014 67 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Optional modules: 10104650 Traditional Chinese text variant CF-108A/ F7.843.423 Membrane GST116A Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 16 Zone Conventional Control and Indicating Equipment Incorporating the following modules: FC-116A/ F7.843.402 CB-116A/ F2.908.1724 DB-116A/ F2.908.1676 XB-116A/ F7.820.1677 Optional modules: 10104651 CF-116A/ F7.843.424 GST200N 548p/06 Membrane Control board with integrated PSE Display board Expansion board Traditional Chinese text variant Membrane Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition Intelligent 2 loop, 30 zone analogue addressable control and indicating equipment 548p/07 Incorporating the following units: MB-220/ F7.820.826a Main board P-9960A/ F7.820.1943 CAN network card loop type board PS-220/ F7.820.1939 Power management board OX-220/ F7.820.1857 Terminal board ZP-220/ F7.820.312d Zone indication and intervention board SB-220/ F7.820.827 Switch board TB-220/ F7.820.828a Loop interface board LC200/ F7.820.1125 Loop board PDF-150-27.5. Powerld SMPS 100-240V power supply Incorporating as optional modular units: P-9930/ F7.820.913a RS-232 board for configuration P-9901A Printer module kit Optional language variants: 10104672 Portuguese language variant 10104674 Hungarian language variant Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points GST200-2/1 Note : Scope of approval does not include network functionality. Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment 548p/08 Incorporating the following units: MB-220/ F7.820.826 Main board SB-220/ F7.820.827 Switch board TB-220/ F7.820.828 Loop interface board PS-220/ F7.820.829b Power supply unit ZP-220/ F7.820.913a Zone indication and intervention board Incorporating as optional modular units: P-9930/ F7.820.913a RS-232 board for configuration P-9901A Printer module kit LC200/ F7.820.1125 Loop board (for loop expansion) Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 68 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.10.1 Type A 7.11 8.3 9.5 GST200-2/1PT Output to automatic Fire Protection Equipment Delays to outputs Fault signals from points Disablement of addressable points Note: can be extended to 2 loop panel by adding LC200 Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment Incorporating the following units: MB-220/ F7.820.826 SB-220/ F7.820.827 TB-220/ F7.820.828 PS-220/ F7.820.829b ZP-220/ F7.820.312d 548p/09 Main board Switch board Loop interface board Power supply unit Zone indication and intervention board Incorporating as optional modular units: P-9930/ F7.820.913a RS-232 board for configuration P-9901A Printer module kit LC200/ F7.820.1125 Loop board (for loop expansion) GST200-2/1HU Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment (Hungarian Varient) Incorporating the following units: MB-220/ F7.820.826 SB-220/ F7.820.827 TB-220/ F7.820.828 PS-220/ F7.820.829b ZP-220/ F7.820.312d board 548p/10 Main board Switch board Loop interface board Power supply unit Zone indication and intervention Incorporating as optional modular units: P-9930/ F7.820.913a RS-232 board for configuration P-9901A Printer module kit LC200/ F7.820.1125 Loop board (for loop expansion) Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Note: Can be extended to 2-loop panel by adding LC200 Haes Systems Limited Columbia House, Packet Boat Lane, Cowley Peachey, Uxbridge, Middlesex UB8 2JP, United Kingdom Tel: +44 (0)1895 422066 • Fax: +44 (0)1895 420603 E-mail: [email protected] • Website: www.haes-systems.co.uk Certificate No: 810a to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products FBUS X-Y-Z 20 Oct 2014 1 to 4 Loop analogue addressable and/or 4-20 Zone conventional control and indicating equipment LPCB Ref. No. 810a/01 69 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating as modular units: FSB17 Main Display PCB FSB10 Expander PCB PSUFUSION-3A 3A Power Supply Control PCB PSULS100-36 36V 100W Lambda Power supply Module Cabinet size 340H x 460W x 120D mm and as optional modules: FSB18 FSB11 FSB10-E FSB12-32 FSB12-64 4 Way Conventional zone PCB 1 Loop Card Apollo protocol Bank Extender PCB 16 Way expansion LED PCB 48 Way expansion LED PCB Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.11 Delays to outputs 9.5 Disablement of each addressable point 10 Test condition Notes: 1. FBUL X-Y-Z Model name suffix X denote the LED display module type, Y denote the number of conventional zones and Z denote the number of loops. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 1 to 8 Loop analogue addressable and/or 4-64 zone conventional control and indicating equipment 810a/02 Incorporating as modular units: FSB17 Main Display PCB FSB10 Expander PCB PSUFUSION-5A 5A Power Supply Control PCB PSULS150-36 36V 150W Lambda Power supply Module Cabinet size 750H x 470W x 140D mm and as optional modules: FSB18 FSB11 FSB10-E FSB12-32 FSB12-64 4 Way Conventional zone PCB 1 Loop Card Apollo protocol Bank Extender PCB 16 Way expansion LED PCB 48 Way expansion LED PCB Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.11 Delays to outputs 9.5 Disablement of each addressable point 10 Test condition Notes: 1. ECLiPSE Model name suffix X denote the LED display module type, Y denote the number of conventional zones and Z denote the number of loops. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 4 and 2 Zone conventional control and indicating equipment 810a/03 ECL-2 Incorporating as modular units: TPC A01- E2 Eclipse two zone main PCB applicable on 2 zone CIE only TPC A02 ZoneFinder LED display PCB PSM1.5 - 24 Power supply 1.5A rated Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.1 Dependency on more than one alarm signal type A 10 Test condition EC-4 70 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating as modular units: TPC A01- E4 Eclipse four zone main PCB applicable on 4 zone CIE only TPC A02 Eclipse LED display PCB PSM1.5 - 24 Power supply 1.5A rated Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.1 Dependency on more than one alarm signal type A 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Excel-EN 2,4, 6, 8 and 12 Zone conventional control and indicating equipment 810a/04 Excel-EN 2 Zone Conventional Control Panel (Manufacturers internal code XLEN-2) Incorporating as modular units: TPCA01-X 2 XLEN 2 Zone Main PCB TPCA03 XLEN Display Board PSM3.0-24 Power Supply Excel-EN 4 Zone Conventional Control Panel (Manufacturers internal code XLEN-4) Incorporating as modular units: TPCA01-X4 XLEN 4 Zone Main PCB TPCA03 XLEN Display Board PSM3.0-24 Power Supply Excel-EN 6 Zone Conventional Control Panel (Manufacturers internal code XLEN-6H) Incorporating as modular units: TPCA01-X2 XLEN 2 Zone Main PCB TPCA03 XLEN Display Board TPCA04-H XLEN High Spec 4 Zone Extension Board PSM3.0-24 Power Supply Excel-EN 6 Zone Conventional Control Panel (Manufacturers internal code XLEN-6) Incorporating as modular units: TPCA01-X2 XLEN 2 Zone Main PCB TPCA03 XLEN Display Board TPCA04-S XLEN Standard 4 Zone Extension Board PSM3.0-24 Power Supply Excel-EN 8 Zone Conventional Control Panel (Manufacturers internal code XLEN-8) Incorporating as modular units: TPCA01-X4 XLEN 4 Zone Main PCB TPCA03 XLEN Display Board TPCA04-H XLEN High Spec 4 Zone Extension Board PSM3.0-24 Power Supply Excel-EN 8 Zone Conventional Control Panel (Manufacturers internal code XLEN-8L) Incorporating as modular units: TPCA01-X4 XLEN 4 Zone Main PCB TPCA03 XLEN Display Board TPCA04-S XLEN Standard 4 Zone Extension Board PSM3.0-24 Power Supply Excel-EN 12 Zone Conventional Control Panel (Manufacturers internal code XLEN-12) Incorporating as modular units: TPCA01-X4 XLEN 4 Zone Main PCB TPCA03 XLEN Display Board TPCA04-S XLEN Standard 4 Zone Extension Board TPCA04-H XLEN High Spec 4 Zone Extension Board PSM3.0-24 Power Supply Excel-EN 12 Zone Conventional Control Panel (Manufacturers internal code XLEN-12L) Incorporating as modular units: TPCA01-X4 XLEN 4 Zone Main PCB TPCA03 XLEN Display Board TPCA04-S Two XLEN Standard 4 Zone Extension Board PSM3.0-24 Power Supply 20 Oct 2014 71 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Excel-EN 12 Zone Conventional Control Panel (Manufacturers internal code XLEN-12H) Incorporating as modular units: TPCA01-X4 XLEN 4 Zone Main PCB TPCA03 XLEN Display Board TPCA04-H Two XLEN High Spec 4 Zone Extension Board PSM3.0-24 Power Supply Certified with the following options with requirements from EN 54 Part 2: AlarmSense 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.1 Dependency on more than one alarm signal type A 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. ALS-2 2 Zone AlarmSense conventional control and indicating equipment ALS-4 4 Zone AlarmSense conventional control and indicating equipment 810a/05 Incorporating as modular units: TPCA02 Eclipse LED Display & Controls Board TPCA06-A2 AlarmSense, 2 Zone main PCB TPCA06-A4 AlarmSense, 4 Zone main PCB (applicable on 4 zone CIE only) PSM1.5 - 24 Power supply 1.5A rated Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.1 Dependency on more than one alarm type A 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. AlarmSense Plus 2,4, 6, 8 and 12 Zone AlarmSense conventional control and indicating equipment 810a/06 ASP-2 2 Zone AlarmSense Conventional Control Panel Incorporating as modular units: TPCA03 XLEN LED Display & Controls Board TPCA06-P2 AlarmSense Plus, 2 Zone main PCB PSM3.0-24 Power Supply Incorporating as optional module: TPCA05 XLEN Communications Board ASP-4 4 Zone AlarmSense Conventional Control Panel Incorporating as modular units: TPCA03 XLEN LED Display & Controls Board TPCA06-P4 AlarmSense Plus, 4 Zone main PCB PSM3.0-24 Power Supply Incorporating as optional module: TPCA05 XLEN Communications Board ASP-6 6 Zone AlarmSense Conventional Control Panel Incorporating as modular units: TPCA03 XLEN LED Display & Controls Board TPCA06-P2 AlarmSense Plus, 2 Zone main PCB TPCA07 AlarmSense Plus, 4 zone extension card PSM3.0-24 Power Supply 72 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating as optional module: TPCA05 XLEN Communications Board ASP-8 8 Zone AlarmSense Conventional Control Panel Incorporating as modular units: TPCA03 XLEN LED Display & Controls Board TPCA06-P4 AlarmSense Plus, 4 Zone main PCB TPCA07 AlarmSense Plus, 4 zone extension card PSM3.0-24 Power Supply Incorporating as optional module: TPCA05 XLEN Communications Board ASP-12 12 Zone AlarmSense Conventional Control Panel Incorporating as modular units: TPCA03 XLEN LED Display & Controls Board TPCA06-P4 AlarmSense Plus, 4 Zone main PCB TPCA07 AlarmSense Plus, 4 zone extension card x 2 PSM3.0-24 Power Supply Incorporating as optional module: TPCA05 XLEN Communications Board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.1 Dependency on more than one alarm signal type A 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 10 Test condition HSC Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 4 and 2 Zone conventional control and indicating equipment 810a/07 HSC-2 Incorporating as modular units: TPCHSC-2 HSC two zone main PCB applicable on 2 zone CIE only TPC A02 HSC LED display PCB PSM1.5 - 24 Power supply 1.5A rated Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.1 Dependency on more than one alarm signal type A 10 Test condition HSC-4 Incorporating as modular units: TPCHSC-4 HSC four zone main PCB applicable on 4 zone CIE only TPC A02 HSC LED display PCB PSM1.5 - 24 Power supply 1.5A rated Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.1 Dependency on more than one alarm signal type A 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13 20 Oct 2014 73 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Honeywell Control Systems Ltd Honeywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United Kingdom Tel: 01344 655609 • Fax: 01344 655474 Website: www.honeywell.com Certificate No: 154g-(cl-1) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products XLS80e Basic Equipment Kit, (BEK): Modular analogue addressable control and indicating equipment. 020-538-101 XLS80e Basic Equipment Kit, Group 1 020-538-103 XLS80e Basic Equipment Kit, Group 3 020-538-104 XLS80e Basic Equipment Kit, Group 4 020-538-105 XLS80e Basic Equipment Kit, Group 5 LPCB Ref. No. 154g/01 Incorporating the following as modular units: Enclosures: 020-040-002 Cover Kit Extended Moulded, Light / Grey 020-472-002 Backbox Kit Standard, Light Grey 020-473-002 Backbox Kit Extended, Light Grey 020-474-002 Backbox Kit Extended Deep, Light Grey 020-475-002 Backbox Kit Double Extended, Light Grey 020-476-002 Backbox Kit Double Extended Deep, Light Grey 020-480-102 Main Cover Kit, Light / Grey 020-481-002 Extension Cover Kit, Light / Grey 020-509-002 Backbox Extension Deep Assembly Light / Grey 020-621-002 256 Zone Extension Cover, Light / Grey 020-541-102 PSU7A / 78Ah Battery Enclosure Modules: 020-708-100 Extension Chassis with Printer Kit 020-644-009 Printer Assembly 020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612-100 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588-100 Honeywell Dual Loop Interface Board, (LIB) 020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 020-648 PSU3A 020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-548 PSU7A Status Indication 020-543 Dual Transmission Path / Booster, PSU Interface 020-773 Routing Termination Unit (DEOL) 020-877 Extinguishing Interface Module M221-SI 020-643 XLS80e-NI Fibre Optic Interface Kit 020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablements of addressable points 10 Test condition Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian 74 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic XLS80e-2L Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. Fixed build 2 loop analogue addressable control and indicating equipment. 020-692 XLS80e-2L-1, 2 Loop, PSU3A, Group 1 020-692-103 XLS80e-2L-3, 2 Loop, PSU3A, Group 3 020-692-104 XLS80e-2L-4, 2 Loop, PSU3A, Group 4 020-692-105 XLS80e-2L-5, 2 Loop, PSU3A, Group 5 154g/01 Incorporating the following as modular units: Enclosures: 020-040-002 Cover Kit Extended Moulded, Light / Grey 020-472-002 Backbox Kit Standard, Light Grey 020-473-002 Backbox Kit Extended, Light Grey 020-474-002 Backbox Kit Extended Deep, Light Grey 020-475-002 Backbox Kit Double Extended, Light Grey 020-476-002 Backbox Kit Double Extended Deep, Light Grey 020-480-102 Main Cover Kit, Light / Grey 020-481-002 Extension Cover Kit, Light / Grey 020-509-002 Backbox Extension Deep Assembly Light / Grey 020-621-002 256 Zone Extension Cover, Light / Grey 020-541-102 PSU7A / 78Ah Battery Enclosure Modules: 020-708-100 Extension Chassis with Printer Kit 020-644-009 Printer Assembly 020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612-100 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588-100 Honeywell Dual Loop Interface Board, (LIB) 020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 020-648 PSU3A 020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-548 PSU7A Status Indication 020-543 Dual Transmission Path / Booster, PSU Interface 020-773 Routing Termination Unit (DEOL) 020-877 Extinguishing Interface Module M221-SI 020-643 XLS80e-NI Fibre Optic Interface Kit 020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablements of addressable points 10 Test condition Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic XLS80e-4L 20 Oct 2014 Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. Fixed build 4 loop analogue addressable control and indicating equipment. 020-693 XLS80e-4L-1, 4 Loop, PSU3A, Group 1 020-693-103 XLS80e-4L-3, 4 Loop, PSU3A, Group 3 154g/01 75 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 020-693-104 020-693-105 XLS80e-4L-4, 4 Loop, PSU3A, Group 4 XLS80e-4L-5, 4 Loop, PSU3A, Group 5 Incorporating the following as modular units: Enclosures: 020-040-002 Cover Kit Extended Moulded, Light / Grey 020-472-002 Backbox Kit Standard, Light Grey 020-473-002 Backbox Kit Extended, Light Grey 020-474-002 Backbox Kit Extended Deep, Light Grey 020-475-002 Backbox Kit Double Extended, Light Grey 020-476-002 Backbox Kit Double Extended Deep, Light Grey 020-480-102 Main Cover Kit, Light / Grey 020-481-002 Extension Cover Kit, Light / Grey 020-509-002 Backbox Extension Deep Assembly Light / Grey 020-621-002 256 Zone Extension Cover, Light / Grey 020-541-102 PSU7A / 78Ah Battery Enclosure Modules: 020-708-100 Extension Chassis with Printer Kit 020-644-009 Printer Assembly 020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612-100 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588-100 Honeywell Dual Loop Interface Board, (LIB) 020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 020-648 PSU3A 020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-548 PSU7A Status Indication 020-543 Dual Transmission Path / Booster, PSU Interface 020-773 Routing Termination Unit (DEOL) 020-877 Extinguishing Interface Module M221-SI 020-643 XLS80e-NI Fibre Optic Interface Kit 020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablements of addressable points 10 Test condition Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic XLS80e-6L Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. Fixed build 6 loop analogue addressable control and indicating equipment. 020-694 XLS80e-6L-1, 6 Loop, PSU7A, Group 1 020-694-103 XLS80e-6L-3, 6 Loop, PSU7A, Group 3 020-694-104 XLS80e-6L-4, 6 Loop, PSU7A, Group 4 020-694-105 XLS80e-6L-5, 6 Loop, PSU7A, Group 5 154g/01 Incorporating the following as modular units: Enclosures: 020-040-002 Cover Kit Extended Moulded, Light / Grey 020-472-002 Backbox Kit Standard, Light Grey 020-473-002 Backbox Kit Extended, Light Grey 76 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 020-474-002 020-475-002 020-476-002 020-480-102 020-481-002 020-509-002 020-621-002 020-541-102 Modules: 020-708-100 020-644-009 020-559-101 020-559-102 020-612-100 020-708-009 020-644-009 020-588-100 020-549-100 020-478 020-479 020-648 020-579 Interface) 020-548 020-543 020-773 020-877 020-643 020-647-100 Panel Backbox Kit Extended Deep, Light Grey Backbox Kit Double Extended, Light Grey Backbox Kit Double Extended Deep, Light Grey Main Cover Kit, Light / Grey Extension Cover Kit, Light / Grey Backbox Extension Deep Assembly Light / Grey 256 Zone Extension Cover, Light / Grey PSU7A / 78Ah Battery Enclosure Extension Chassis with Printer Kit Printer Assembly Zone Extension Chassis Kit 1-64 Zone C/W Display Module Zone Extension Chassis Kit 65-128 Zone C/W Display Module Double Extended Chassis Kit 256 Zone Extension Chassis with Printer Printer Assembly Honeywell Dual Loop Interface Board, (LIB) Honeywell Dual Enhanced Loop Interface Board, (ELIB) RS232 Interface RS485 Interface PSU3A PSU7A, (Requires Dual Transmission Path / Booster, PSU PSU7A Status Indication Dual Transmission Path / Booster, PSU Interface Routing Termination Unit (DEOL) Extinguishing Interface Module M221-SI XLS80e-NI Fibre Optic Interface Kit XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablements of addressable points 10 Test condition Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic XLS80e-8L Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. Fixed build 8 loop analogue addressable control and indicating equipment. 020-695 XLS80e-8L-1, 8 Loop, PSU7A, Group 1 020-695-103 XLS80e-8L-3, 8 Loop, PSU7A, Group 3 020-695-104 XLS80e-8L-4, 8 Loop, PSU7A, Group 4 020-695-105 XLS80e-8L-5, 8 Loop, PSU7A, Group 5 154g/01 Incorporating the following as modular units: Enclosures: 020-040-002 Cover Kit Extended Moulded, Light / Grey 020-472-002 Backbox Kit Standard, Light Grey 020-473-002 Backbox Kit Extended, Light Grey 020-474-002 Backbox Kit Extended Deep, Light Grey 020-475-002 Backbox Kit Double Extended, Light Grey 020-476-002 Backbox Kit Double Extended Deep, Light Grey 020-480-102 Main Cover Kit, Light / Grey 020-481-002 Extension Cover Kit, Light / Grey 020-509-002 Backbox Extension Deep Assembly Light / Grey 020-621-002 256 Zone Extension Cover, Light / Grey 020-541-102 PSU7A / 78Ah Battery Enclosure 20 Oct 2014 77 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Modules: 020-708-100 020-644-009 020-559-101 020-559-102 020-612-100 020-708-009 020-644-009 020-588-100 020-549-100 020-478 020-479 020-648 020-579 Interface) 020-548 020-543 020-773 020-877 020-643 020-647-100 Panel Extension Chassis with Printer Kit Printer Assembly Zone Extension Chassis Kit 1-64 Zone C/W Display Module Zone Extension Chassis Kit 65-128 Zone C/W Display Module Double Extended Chassis Kit 256 Zone Extension Chassis with Printer Printer Assembly Honeywell Dual Loop Interface Board, (LIB) Honeywell Dual Enhanced Loop Interface Board, (ELIB) RS232 Interface RS485 Interface PSU3A PSU7A, (Requires Dual Transmission Path / Booster, PSU PSU7A Status Indication Dual Transmission Path / Booster, PSU Interface Routing Termination Unit (DEOL) Extinguishing Interface Module M221-SI XLS80e-NI Fibre Optic Interface Kit XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablements of addressable points 10 Test condition Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic XLS80e-NI Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. 002-467-002 Network Gateway Unit, (NGU) Honeywell Protocol 154g/NO1 Incorporating the following as modular units: 020-643 XLS80e- NI Fibre Optic Interface Kit 020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel 020-648 PSU3A Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. 78 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Honeywell International Inc 1500 West Dundee Road, Arlington Heights IL 60004, USA Tel: +1 847 797 4403 • Fax: +1 847 797 3664 Website: www.honeywell.com Certificate No: 262z-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 262ab-(cl-1) to EN54-2: 1997+A1:2006, EN54-4:1997+A1:2002+A2:2006, EN54-16:2008 Control and indicating equipment Certificated Products XLS1000 Incorporating as modular units: Annunciators LPCB Ref. No. 262ab/01 EST3 24 LED Annunciators 3-24Y Annunciator Bill of Materials 3-24Y-E Annunciator Bill of Materials 3-24R Annunciator Bill of Materials 3-24R-E Annunciator Bill of Materials 3-24G Annunciator Bill of Materials 3-24G-E Annunciator Bill of Materials 3-12RY Annunciator Bill of Materials 3-12RY-E Annunciator Bill of Materials EST3 18 LED Annunciators 3-6/3S1G2Y 3-6/3S1G2Y Annunciator Bill of Materials 3-6/3S1G2Y-E 3-6/3S1G2Y Annunciator Bill of Materials 3-6/3S1GYR 3-6/3S1GYR Annunciator Bill of Materials 3-6/3S1GYR-E 3-6/3S1GYR Annunciator Bill of Materials 3-6/3S2RY 3-6/3S2RY Annunciator Bill of Materials EST3 Control-Display Switch/LEDs 3-12SY 3-12SY 12 Switch-Yellow Bill of Materials 3-12SY-E 3-12SY 12 Switch-Yellow Bill of Materials 3-12SR 3-12SR 12 Switch-Red Bill of Materials 3-12SR-E 3-12SR 12 Switch-Red Bill of Materials 3-12SG 3-12SG 12 Switch-Green Bill of Materials 3-12SG-E 3-12SG 12 Switch-Green Bill of Materials 3-12/S1GY 3-12/S1GY 12 Switch-Green/Yellow 3-12/S1GY-E 3-12/S1GY 12 Switch-Green/Yellow 3-12/S1RY 3-12/S1RY 12 Switch-Red/Yellow Bill of Materials 3-12/S1RY-E 3-12/S1RY 12 Switch-Red/Yellow Bill of Materials 3-12/S2Y 3-12/S2Y - 12 Switches - 24 Yellow Bill of Materials 3-12/S2R 3-12/S2R - 12 Switches - 24 Red Bill of Materials Loop Controller Modules 3-SSDC1-E Signature (Single), driver controller module 3-DSDC1-E Signature (Dual), driver controller module 3-AADC1-E System Sensor driver control module 3-SDC1-E Signature, driver controller module 3-EAC-E Edwards Analog Driver Card 3-EASC-E Edwards (Single) Analogue driver controller module 3-EADC-E Edwards (Dual) Analogue driver controller module Power Supplies 3-PPS/M-230-E Primary Power Supply 230V 3-BPS/M-230-E Booster Power Supply 230V 3-BBC/M-230-E Booster, Battery Charger Power Supply 230V 3-PSMON-E Primary Power Supply Monitor 3-BPMON-E Booster Power Supply Monitor 3-BBCMON-E Booster, Battery Charger Monitor 3-CPU3 Central Processor Unit 3-CPU3-E Central Processor Unit 3-LDSM Annunciator strip support module 3-LDSM-E Annunciator strip support module 3-IDC 8/4 Initiating Device Circuits/NACS 3-IDC 8/4-E Initiating Device Circuits/NACS 3-LCD EST3 Main Display LCD, user interface 3-LCD-E EST3 Main Display LCD, user interface 20 Oct 2014 79 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 3-LRMF Local Rail Module Filler 3-RS485A Data Communication, Class A 3-RS485A-E Data Communication, Class A 3-RS485B Data Communication, Class B 3-RS485B-E Data Communication, Class B 3-RS232 Serial Communications Card (Printer, etc) 3-RS232-E Serial Communications Card (Printer, etc) EFM-2 Data Communications Filter - 2 Circuits EFM-10 Data Communications Filter - 10 Circuits Cabinets & Door Assemblies 3-CAB7B-E Cabinet Back Box 3-CAB7B-E 3-CAB14B-E Cabinet Back Box 3-CAB14B-E 3-CAB21B-E Cabinet Back Box 3-CAB21B-E Lobby Cabinet Assemblies XLS-CAB7D(R)-E XLS-CAB7D-E Door Assembly - (R) indicates red XLS-CAB14D(R)-E XLS-CAB14D-E Door Assembly - (R) indicates red XLS-CAB21D(R)-E XLS-CAB21D-E Door Assembly - (R) indicates red Battery Cabinets XLS-RCC7R-E XLS - CAB 7 Module Chassis - Remote Closet Cabinet XLS-RCC14R-E XLS - CAB 14 Module Chassis - Remote Closet Cabinet XLS-RCC21R-E XLS - CAB 21 Module Chassis - Remote Closet Cabinet 3-BTSEN-E Remote battery cabinet interlace, temperature sensing XLS BC-1 Battery Cabinet 3-TAMP Cabinet Tamper Switch for 3-CAB7/14/21 3-TAMPRCC Tamper Switch for 3-RCC Cabinet Audio & Telephone Common Controls - Chassis Assemblies 3-CHAS7 EST3 - CHASSIS 7 Module - Chassis Assy for 7 LRMs 3-CHAS7-E EST3 - CHASSIS 7 Module - Chassis Assy for 7 LRMs 3-CHASS4 EST3 -CHASSIS 4 Mod - Chassis Assy for REMIC & 4 LRMs 3-CHASS4-E EST3 -CHASSIS 4 Mod - Chassis Assy for REMIC & 4 LRMs 3-ASU-E Audio Source Unit with a 3-Chassis - European 3-ASU/4-E Audio Source Unit with 4 LRM slots - European 3-ASUMX/100 100 minute extended audio memory card 3-ASU/FT-EN Audio Source Unit with Fire Fighter Tele - European 3-FTCU-E Firefighter Telephone Control Unit 3-ZA20A 20 watt Zone Amplifier, Class A 3-ZA20A-E 20 watt Zone Amplifier, Class A 3-ZA20B 20 watt Zone Amplifier, Class B 3-ZA20B-E 20 watt Zone Amplifier, Class B 3-ZA40A 40 watt Zone Amplifier, Class A 3-ZA40A-E 40 watt Zone Amplifier, Class A 3-ZA40B 40 watt Zone Amplifier, Class B 3-ZA40B-E 40 watt Zone Amplifier, Class B 3-BATS Battery Shelf for Single 65AH Cell 3-CBLKIT1 EST3 Extended Rail Cable Kit 3-CPUDR EST3 CPU Door Kit Certified with the following options with requirements from EN 54-2 7.8 7.13 8.3 10 Output to fire alarm devices Alarm counter Fault Signals from points Test condition Certified with the following options with requirements from EN 54-16 XLS1000 80 7.3 Audible warning 7.4 Delay(s) to entering the voice alarm condition 7.5 Phased evacuation 7.6.2 Manual silencing of the voice alarm condition 7.7.2 Manual reset of the voice alarm condition 7.9 Voice alarm condition output 8.4 Indication of faults related to voice alarm zones 9 Disablement condition 10 Voice alarm manual control 12 Emergency microphone(s) 13.14 Redundant power amplifier Control and indicating equipment 262z/01 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating as modular units: XLS1000 3-SSDC1-E Signature (Single), driver controller module 3-SDDC1-E Signature (Dual), driver controller module 3-AADC1-E System Sensor driver control module 3-EASC-E Edwards (Single) Analogue driver controller module 3-EADC-E Edwards (Dual) Analogue driver controller module 3-PPS/M-230-E Primary Power Supply 3-BPS/M-230-E Booster Power Supply 3-BBC/M-230-E Booster Battery Charger Power Supply 3-ASU Audio Source Unit 3-ASU/FT-E Audio Source Unit with Fire Fighter Telephone 3-ASUMX/100 100 minute extended audio memory card 3ASU/4 Audio Source Unit with 4 Local Rail Modules (LRM) slots 3-ZA20A 20 watt Zone Amplifier, Class A 3-ZA20B 20 watt Zone Amplifier, Class B 3-ZA40A 40 watt Zone Amplifier, Class A 3-ZA40B 40 watts Zone Amplifier, Class B 3-CPU3 Central Processor Unit EFM-2 Data Communications Filter 3-ZA95 95 watt Zone Amplifier, Class A 3-CAB7-E 7 Slot Cabinet 3-CAB14-E 14 Slot Cabinet 3-CAB21-E 21 Slot Cabinet 3-CAB7D(R)-E Door for 7 Slot Cabinet, (R) indicates red 3-CAB14D(R)-E Door for 14 Slot Cabinet, (R) indicates red 3-CAB21D(R)-E Door for 21 Slot Cabinet, (R) indicates red 3-RCC7R-E Small Remote Battery Cabinet 3-RCC14R-E Medium Remote Battery Cabinet 3-RCC21R-E Large Remote Battery Cabinet 3-LCD Liquid Crystal Display, user interface 3-BATSEN-E Remote battery cabinet interface, temperature sensing 3-BATSEN Remote battery cabinet interface 3-BATS Battery Shelf 3-RS485A Data Communication, Class A 3-RS485B Data Communication, Class B 3-RS232 Serial Communications Card (Printer, etc) 3-PSMON Primary Power Supply Monitor 3-IDC8/4 Initiating Device Circuits/NACS 3-24R 24, Red 3-24Y 24, Yellow 3-24G 24, Green 3-12RY Red-over-yellow pairs 3-12SR 12 Switches. Red 3-12SY 12 Switches. Yellow 3-12SG 12 Switches. Green 3-12/S1GY 12 Switches. Green over-yellow pairs 3-12/S1RY 12 Switches. Red over-yellow pairs 3-12/S2Y 24, Yellow, 12 Switches 3-12/S2R 24, Red, 12 Switches 3-6/3S1G2Y Green-over-yellow-over-yellow triads, 6 triads 3-6/3S1GYR Green-over-yellow-over-red triads, 6 triads 3-6/3S2RY Red-over-yellow-over-red triads, 6 triads 3-BBCMON Booster, Battery Charger Monitor 3-BPSMON Booster Power supply Monitor 3-LDSM Annunciator strip support module 3-LRMF Local Rail Module Filler 3-FTCU MB Fire fighter Telephone Control Unit MB 3-FTCU-E Fire fighter Telephone Control Unit Display 3-REMICP Remote Microphone, Panel 3-RCIC ASU Interconnect power and rail communication unit Repeater 262z/01R Incorporating as modular units: 3-RS485BA Remote Annunciator RS485 Communications. 3-ANNCPU3 Remote Annunciator CPU 3-LCDANN-E LCD Display and User Interface for Remote Annunciator 3-ANNSM Remote (repeater) Annunciator Support Module 3-REMICA Remote paging Microphone 3-24Y 24, Yellow 20 Oct 2014 81 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 3-12/S1GY 12 Switches. Green over-yellow pairs 3-6ANN-E(R) Remote Annunciator Back Box, 6 slots, with Door (R) indicates red 3-10ANN-E(R) Remote Annunciator Back Box, 10 slots, with Door (R) indicates red Certified with the following options with requirements from EN 54 Part 2: 7.8 7.13 8.3 10 Output to fire alarm devices Alarm counter Fault Signals from points Test condition Notes: 1. Scope of approval does not include system compatibility. Kentec Electronics Limited Units 25-27, Fawkes Avenue, Questor, Dartford, Kent DA1 1JQ, United Kingdom Tel: +44 (0)1322 222121 • Fax: +44 (0)1322 291794 E-mail: [email protected] • Website: www.kentec.co.uk Certificate No: 360a to EN 54-4:1997+A1:2002+A2:2006 Power Supply Equipment Certificated Products K25800 03 10.25 A Power supply with maximum 8Ah Batteries LPCB Ref. No. 360a/01 KD25800 03 Incorporating the following units: S408 Power supply module S584 Power supply LED indication PCB Dual O/P 10.25 A Power supply with maximum 8Ah Batteries 360a/02 Incorporating the following units: K25800 15 S408 Power supply module S584 Power supply LED indication PCB S789 Dual output PCB 10.25 A Power supply with maximum 45Ah Batteries 360a/03 KD25800 15 Incorporating the following units: S408 Power supply module S584 Power supply LED indication PCB Dual O/P 10.25 A Power supply with maximum 45Ah Batteries 360a/04 K25800 M3 Incorporating the following units: S408 Power supply module S584 Power supply LED indication PCB S789 Dual output PCB 10.25 A Power supply with maximum 18Ah Batteries in M3 housing 360a/05 KD25800 M3 Incorporating the following units: S408 Power supply module S584 Power supply LED indication PCB Dual O/P 10.25 A Power supply with maximum 18Ah Batteries 360a/06 K25800 D3 Incorporating the following units: S408 Power supply module S584 Power supply LED indication PCB S789 Dual output PCB 10.25 A Power supply with maximum 45Ah Batteries in D3 housing 360a/07 Incorporating the following units: S408 Power supply module S584 Power supply LED indication PCB 82 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products KD25800 D3 Dual O/P 10.25 A Power supply with maximum 18Ah Batteries in D3 housing LPCB Ref. No. 360a/08 Incorporating the following units: S408 Power supply module S584 Power supply LED indication PCB S789 Dual output PCB Mavili Elektronik Ticaret Ve Sanayi A.S. Bostanci Dudullu Yolu, Kutup Sok, No. 29 Y Dudullu - Umraniye, Istanbul TR 34775, Turkey Tel: +90 216 4664 505 • Fax: +90 216 4664 510 E-mail: [email protected] • Website: www.mavigard.com Certificate No: 926d to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products ML-1231.EN Maxlogic intelligent analogue addressable 1 Loop, 127 addressable devices, 64 Zone control and indicating equipment. LPCB Ref. No. 926d/01 Incorporating the following units: MLY-1202.EN Main MCU module MLY-1203 Zone LED module MLY-1200 SLCU module MLY-0500-EN PSU unit ML-1201 Optional Network module 542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane Certified with the following options with requirements from EN 54-2:1997 ML-1241.P.EN 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.11 Delays to the auctioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13. Maxlogic intelligent analogue addressable 1 Loop, 127addressable devices, 64 Zone control and indicating equipment with printer 926d/01 Incorporating the following units: MLY-1202.EN Main MCU module MLY-1203 Zone LED module MLY-1200 SLCU module MLY-0500-EN PSU unit ML-1203 Printer module ML-1201 Optional Network module 542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane Certified with the following options with requirements from EN 54-2:1997 7.8 20 Oct 2014 Output to fire alarm device(s) 83 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.9.1 7.11 ML-1232.EN Output to fire alarm routing equipment Delays to the auctioning of outputs fire alarm devices and fire routing equipment Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Alarm counter Fault signals from points Disablement of each address point Test condition 7.12.1 7.12.2 7.12.3 7.13 8.3 9.5 10 Notes: 1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13. Maxlogic intelligent analogue addressable 2 Loop, 254 addressable devices, 64 Zone control and indicating equipment 926d/02 Incorporating the following units: MLY-1202.EN Main MCU module MLY-1203 Zone LED module MLY-1200 SLCU module MLY- 0500-EN PSU unit ML-1201 Optional Network module 542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane Certified with the following options with requirements from EN 54-2:1997 7.8 7.9.1 7.11 ML-1242.P.EN Output to fire alarm device(s) Output to fire alarm routing equipment Delays to the auctioning of outputs fire alarm devices and fire routing equipment Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Alarm counter Fault signals from points Disablement of each address point Test condition 7.12.1 7.12.2 7.12.3 7.13 8.3 9.5 10 Notes: 1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13. Maxlogic intelligent analogue addressable 2 Loop, 254 addressable devices, 64 Zone control and indicating equipment with printer. 926d/02 Incorporating the following units: MLY-1202.EN Main MCU module MLY-1203 Zone LED module MLY-1200 SLCU module MLY- 0500-EN PSU unit ML-1203 Printer module ML-1201 Optional Network module 542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane Certified with the following options with requirements from EN 54-2:1997 7.8 7.9.1 7.11 7.12.1 7.12.2 7.12.3 7.13 84 Output to fire alarm device(s) Output to fire alarm routing equipment Delays to the auctioning of outputs fire alarm devices and fire routing equipment Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Alarm counter 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products ML-1233.EN LPCB Ref. No. 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13. Maxlogic intelligent analogue addressable 3 Loop, 381 addressable devices, 64 Zone control and indicating equipment. 926d/03 Incorporating the following units: MLY-1202.EN Main MCU module MLY-1203 Zone LED module MLY-1200 SLCU module MLY- 0500-EN PSU unit ML-1201 Optional Network module 542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane Certified with the following options with requirements from EN 54-2:1997 7.8 7.9.1 7.11 ML-1234.EN Output to fire alarm device(s) Output to fire alarm routing equipment Delays to the auctioning of outputs fire alarm devices and fire routing equipment Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Alarm counter Fault signals from points Disablement of each address point Test condition 7.12.1 7.12.2 7.12.3 7.13 8.3 9.5 10 Notes: 1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13. Maxlogic intelligent analogue addressable 4 Loop, 508 addressable devices, 64 Zone CIE 926d/03 Incorporating the following units: MLY-1202.EN Main MCU module MLY-1203 Zone LED module MLY-1200 SLCU module MLY- 0500-EN PSU unit ML-1201 Optional Network module 542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane Certified with the following options with requirements from EN 54-2:1997 7.8 7.9.1 7.11 ML-1243.P.EN 20 Oct 2014 Output to fire alarm device(s) Output to fire alarm routing equipment Delays to the auctioning of outputs fire alarm devices and fire routing equipment Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Alarm counter Fault signals from points Disablement of each address point Test condition 7.12.1 7.12.2 7.12.3 7.13 8.3 9.5 10 Notes: 1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13. Maxlogic intelligent analogue addressable 3 Loop, 381 addressable devices, 64 Zone 926d/03 85 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. control and indicating equipment with printer. Incorporating the following units: MLY-1202.EN Main MCU module MLY-1203 Zone LED module MLY-1200 SLCU module MLY- 0500-EN PSU unit ML-1203 Printer module ML-1201 Optional Network module 542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane Certified with the following options with requirements from EN 54-2:1997 7.8 7.9.1 7.11 ML-1244.P.EN Output to fire alarm device(s) Output to fire alarm routing equipment Delays to the auctioning of outputs fire alarm devices and fire routing equipment Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Alarm counter Fault signals from points Disablement of each address point Test condition 7.12.1 7.12.2 7.12.3 7.13 8.3 9.5 10 Notes: 1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13. Maxlogic intelligent analogue addressable 4 Loop, 508 addressable devices, 64 Zone control and indicating equipment with printer. 926d/04 Incorporating the following units: MLY-1202.EN Main MCU module MLY-1203 Zone LED module MLY-1200 SLCU module MLY- 0500-EN PSU unit ML-1203 Printer module ML-1201 Optional Network module 542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane Certified with the following options with requirements from EN 54-2:1997 7.8 7.9.1 7.11 Ml-22102 Output to fire alarm device(s) Output to fire alarm routing equipment Delays to the auctioning of outputs fire alarm devices and fire routing equipment Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Alarm counter Fault signals from points Disablement of each address point Test condition 7.12.1 7.12.2 7.12.3 7.13 8.3 9.5 10 Notes: 1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13. Maxlogic Two Zone Conventional Control and Indicating Equipment Incorporating the units: ML-221XX_V1.1 / ML-22102 Main Board Module MLY-0511_V1 / MLY-0511 Power Supply Board and as optional modules: 542.212 / ML-22102 542.211 / ML-22102 86 926d/05 English text membrane Turkish text membrane 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products Ml-22104 LPCB Ref. No. 542.213 / ML-22102 Russian text membrane Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices Maxlogic Four Zone Conventional Control and Indicating Equipment Incorporating the units: ML-221XX_V1.1 / ML-22104 Main Board Module MLY-0511_V1 / MLY-0511 Power Supply Board and as optional modules: 542.215 / ML-22104 542.214 / ML-22104 542.216 / ML-22104 Ml-22108 Ml-22116 926d/06 English text membrane Turkish text membrane Russian text membrane Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices Maxlogic Eight Zone Conventional Control and Indicating Equipment Incorporating the units: ML-221XX_V1.1 / ML-22108 Main Board Module MLY-0511_V1 / MLY-0511 Power Supply Board and as optional modules: 542.218 / ML-22108 English text membrane 542.217 / ML-22108 Turkish text membrane 542.219 / ML-22108 Russian text membrane Maxlogic Sixteen Zone Conventional Control and Indicating Equipment Incorporating the units: ML-221XX_V1.1 / ML-22116 ML_Zone_Extand_V1 / ML-22116 MLY-0511_V1 / MLY-0511 Main Board Module Expansion Board Module Power Supply Board and as optional modules: 542.221 / ML-22116 542.220 / ML-22116 542.222 / ML-22116 English text membrane Turkish text membrane Russian text membrane 926d/07 926d/08 Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices Morley-IAS Fire Systems By Honeywell Honeywell Fire Systems, BSEL Tech Park, Floor 6,Sector 30A, Opposite Vshi Station, Vashi, New Mumbai, India Tel: +91 022 67122427 • Fax: +91 022 67122422 E-mail: [email protected] • Website: www.myhoneywell.com Certificate No: 550g-(cl-1) to EN54-2:1997+A1:2006 and EN54-4:1997+A1:2002+A2:2006 Control and indicating equipment Certificated Products DXc1-S DXc1-M 20 Oct 2014 Single loop control and indicating equipment 714-001-111 PANEL DXc1-S SINGLE LOOP REGION 1 (UK & Iceland) 714-001-112 PANEL DXc1-S SINGLE LOOP REGION 2 (Iberia, India & ME) 714-001-113 PANEL DXc1-S SINGLE LOOP REGION 3 (Dutch, French, Italian, Slovenian) Incorporating as modular units: 124-410-001 Base PCB 1 Loop 124-411 Display PCB 010-115 PSU RS-50-24 Single loop control and indicating equipment 714-001-111 PANEL DXc1-M SINGLE LOOP REGION 1 (UK & Iceland) 714-001-112 PANEL DXc1-M SINGLE LOOP REGION 2 (Iberia, India & ME) 714-001-113 PANEL DXc1-M SINGLE LOOP REGION 3 (Dutch, French, Italian, Slovenian) 714-001-114 PANEL DXc1-M SINGLE LOOP REGION 4 (German) Incorporating as modular units: LPCB Ref. No. 550g/01 550g/02 87 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products DXc2-M DXc4-M LPCB Ref. No. 124-410-001 Base PCB 1 Loop 124-411 Display PCB 010-115 PSU RS-50-24 Two loop control and indicating equipment 714-001-221 PANEL DXc2-M TWO LOOP REGION 1 (UK & Iceland) 714-001-222 PANEL DXc2-M TWO LOOP REGION 2 (Iberia, India & ME) 714-001-223 PANEL DXc2-M TWO LOOP REGION 3 (Dutch, French, Italian, Slovenian) Incorporating as modular units: 124-410 Base PCB 2 Loop 124-411 Display PCB 010-116 PSU RS-100-24 Four loop control and indicating equipment 714-001-241 PANEL DXc4-M FOUR LOOP REGION 1 (UK & Iceland) 714-001-242 PANEL DXc4-M FOUR LOOP REGION 2 (Iberia, India & ME) 714-001-243 PANEL DXc4-M FOUR LOOP REGION 3 (Dutch, French, Italian, Slovenian) Incorporating as modular units: 124-410 Base PCB 2 Loop 124-411 Display PCB 124-417 2 Loop PCB 010-116 PSU RS-100-24 Incorporating as optional modular units: 795-099 KIT DXc NETWORK CARD 795-102 KIT DXc 40 ZONE LED CARD 795-103 KIT DXc 80 ZONE LED CARD WITH COVER 795-111 KIT DXc 2 LOOP EXPANSION CARD (Applicable to the two loop CIE only) 795-117 KIT DXc PERFORMANCE CARD 795-118 KIT DXc KEYSWITCH 795-122 KIT DXc RS232 795-123 KIT DXc RS485 795-124 KIT DXc 80 ZONE LED CARD Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal-Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each addressable point 10 Test condition 550g/03 550g/04 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Morley-IAS Fire Systems by Honeywell (Pittway Systems Technology Group (Europe) Ltd) Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888 E-mail: [email protected] • Website: www.morley-ias.co.uk Certificate No: 429c to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products ZX1Se 1 loop analogue addressable control and indicating equipment LPCB Ref. No. 429c/04 722-001-301 1 loop multi-protocol control panel, language group M100 722-001-302 1 loop multi-protocol control panel, language group M200 722-002-301 1 loop multi-protocol control panel, language group M100, Stainless Steel 722-101-301 1 loop multi-protocol control panel, language group H100 722-101-302 1 loop multi-protocol control panel, language group H200 Incorporating the following units: 88 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 795-072-100 795-068-100 795-058-105 795-066-100 795-044-001 795-004-001 795-005 124-206 124-209-005 124-370 PS82-2-NFR ZX2Se Morley-IAS Loop Driver Card System Sensor Loop Driver Card Hochiki Loop Driver Card Apollo XP95 / Discovery Loop Driver Card Nittan Loop Driver Card RS 485 Communication Module RS232 Communication Module Processor Card 1 Loop Base Card 4 Line Display Card 2A PSU Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal: Type C 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 1-2 loop analogue addressable control and indicating equipment 429c/05 720-001-301 720-001-302 720-002-301 1-2 loop multi-protocol control panel, language group M100 1-2 loop multi-protocol control panel, language group M200 1-2 loop multi-protocol control panel, language group M100, Stainless Steel 720-101-301 1-2 loop multi-protocol control panel, language group H100 720-101-302 1-2 loop multi-protocol control panel, language group H200 Incorporating the following units: 795-072-100 795-068-100 795-058-105 795-066-100 795-044-001 795-004-001 795-005 124-206 124-209-004 124-370 4 PS82-2-NFR ZX5Se Morley-IAS Loop Driver Card System Sensor Loop Driver Card Hochiki Loop Driver Card Apollo XP95 / Discovery Loop Driver Card Nittan Loop Driver Card RS 485 Communication Module RS232 Communication Module Processor Card 2 Loop Base Card Line Display Card 2A PSU Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal: Type C 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 1-5 loop analogue addressable control and indicating equipment 429c/06 721-001-301 721-001-302 721-002-301 1-5 loop multi-protocol control panel, language group M100 1-5 loop multi-protocol control panel, language group M200 1-5 loop multi-protocol control panel, language group M100, Stainless Steel 721-101-301 1-5 loop multi-protocol control panel, language group H100 721-101-302 1-5 loop multi-protocol control panel, language group H200 Incorporating the following units: 795-072-100 795-068-100 795-058-105 795-066-100 795-044-001 795-004-001 795-005 795-077-020 795-077-060 795-051-001 124-206 124-403 124-370 4 PS196-4-NFR 20 Oct 2014 Morley-IAS Loop Driver Card System Sensor Loop Driver Card Hochiki Loop Driver Card Apollo XP95 / Discovery Loop Driver Card Nittan Loop Driver Card RS 485 Communication Module RS232 Communication Module 20 Zone LED Display Indicator Card 60 Zone LED Display Indicator Card Internal Printer Module Processor Card 5 Loop Base Card Line Display Card PSU 89 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products HRZ2-8e 2 Zone HRZ2-8e 4 Zone HRZ2-8e 8 Zone DXc1-S DXc2-M DXc4-M LPCB Ref. No. Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal: Type C 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 002-479-122 Language region 1, English manual 002-479-222 Language region 2 002-479-322 Language region 3, dual relay 002-492-222 Language region 2, English manual, dual relay 002-506-222 Language region 2, English manual 002-479-142 Language region 1, English manual 002-479-242 Language region 2 002-479-342 Language region 3, dual relay 002-492-242 Language region 2, English manual, dual relay 002-506-242 Language region 2, English manual 002-479-182 Language region 1, English manual 002-479-282 Language region 2 002-479-382 Language region 3, dual relay 002-492-282 Language region 2, English user manual, dual relay 002-506-282 Language region 2, English user manual Incorporating the following units: 020-747 8-way relay kit 020-772 4-way monitored sounder kit Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition Single loop control and indicating equipment 714-001-111 PANEL DXc1-S SINGLE LOOP REGION 1 (UK & Iceland) 714-001-112 PANEL DXc1-S SINGLE LOOP REGION 2 (Iberia, India & ME) 714-001-113 PANEL DXc1-S SINGLE LOOP REGION 3 (Dutch, French, Italian, Slovenian) Incorporating as modular units: 124-410-001 Base PCB 1 Loop 124-411 Display PCB 010-115 PSU RS-50-24 Two loop control and indicating equipment 714-001-221 PANEL DXc2-M TWO LOOP REGION 1 (UK & Iceland) 714-001-222 PANEL DXc2-M TWO LOOP REGION 2 (Iberia, India & ME) 714-001-223 PANEL DXc2-M TWO LOOP REGION 3 (Dutch, French, Italian, Slovenian) Incorporating as modular units: 124-410 Base PCB 2 Loop 124-411 Display PCB 010-116 PSU RS-100-24 Four loop control and indicating equipment 714-001-241 PANEL DXc4-M FOUR LOOP REGION 1 (UK & Iceland) 714-001-242 PANEL DXc4-M FOUR LOOP REGION 2 (Iberia, India & ME) 714-001-243 PANEL DXc4-M FOUR LOOP REGION 3 (Dutch, French, Italian, Slovenian) Incorporating as modular units: 124-410 Base PCB 2 Loop 124-411 Display PCB 124-417 2 Loop PCB 010-116 PSU RS-100-24 429c/10 429c/11 429c/12 429c/13 429c/14 429c/15 Incorporating as optional modular units: 795-099 KIT DXc NETWORK CARD 795-102 KIT DXc 40 ZONE LED CARD 795-103 KIT DXc 80 ZONE LED CARD WITH COVER 90 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 795-111 CIE only) 795-117 795-118 795-122 795-123 795-124 KIT DXc 2 LOOP EXPANSION CARD (Applicable to the two loop KIT DXc PERFORMANCE CARD KIT DXc KEYSWITCH KIT DXc RS232 KIT DXc RS485 KIT DXc 80 ZONE LED CARD Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal-Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each addressable point 10 Test condition Notes: 1. 2. DXc1-M This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Single loop and indicating equipment 714-001-111 PANEL DXc1-S SINGLE LOOP REGION 1 Iceland) 714-001-112 PANEL DXc1-S SINGLE LOOP REGION 2 (Iberia, India & ME) 714-001-113 PANEL DXc1-S SINGLE LOOP REGION 3 (Dutch, French, Italian, Slovenian) 714-001-114 PANEL DXc1-S SINGLE LOOP REGION 4 (German) 429c/16 (UK & Incorporating as modular units: 124-410-001 Base PCB 1 Loop 124-411 Display PCB 010-115 PSU RS-50-24 Multron Systems Pte Ltd 217 Kallang Bahru, Multron Building, Singapore 339 347, Singapore Tel: +65 6743 2555 / 6395 6868 • Fax: +65 6743 2777 / 6395 6869 E-mail: [email protected] • Website: www.multron.com Certificate No: 548j-(cl-6) to EN 54-2: 1997 & EN 54-4: 1997 Certificate No: 548p-(cl-3) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products MPC-101 Single zone conventional control and indicating equipment LPCB Ref. No. 548j/02 MPC-102 Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Two zone conventional control and indicating equipment 548j/03 MPC-104 Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Four zone conventional control and indicating equipment 548j/04 Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 20 Oct 2014 91 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. MPC-108 10 Test condition Eight zone conventional control and indicating equipment 548j/05 MPC-116 Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Sixteen zone conventional control and indicating equipment 548j/06 IFP2 Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment 548p/01 Incorporating the following units: MB-220/ F7.820.826 SB-220/ F7.820.827 TB-220/ F7.820.828 PS-220/ F7.820.829b ZP-220/ F7.820.312d Zone Main board Switch board Loop interface board Power supply unit indication and intervention board Incorporating as optional modular units: P-9930/ F7.820.913a RS-232 board for configuration P-9901A Printer module kit LC200/ F7.820.1125 Loop board (for loop expansion) IFP8 Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment 548p/02 Incorporating the following units: SB-800/ F7.820.1238 Indication board LCIFP8/ F7.820.1239 Loop board PB-800/ F7.820.1311 Power board ZP-800/ F7.820.1312 ZCP board KB-800/ F7.820.1326 Keypad board MB-800/ F7.820.1237 Main board MO-800/ F7.820.1310 Mother board Incorporating as optional modular units: P-9935/ F7.820.1313 USB communication board Certified with the following options with requirements from EN 54 Part 2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.11 7.12.1 7.12.2 7.13 8.3 9.5 10 IFP2/1 Output to fire alarm devices Output to fire routing equipment Alarm confirmation input from fire routing equipment Output type A Output type B Delays to outputs Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Alarm counter Fault signals from points Disablement of each address point Test condition Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment Incorporating the following units: MB-220/ F7.820.826 Main board SB-220/ F7.820.827 Switch board TB-220/ F7.820.828 Loop interface board PS-220/ F7.820.829b Power supply unit ZP-220/ F7.820.312d Zone indication and intervention board 548P/08 Incorporating as optional modular units: 92 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. P-9930/ F7.820.913a RS-232 P-9901A LC200/ F7.820.1125 board for configuration Printer module kit Loop board (for loop expansion) Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Nitin Ventures FZE P.O. Box 262294, Jebel Ali Free Zone, Dubai, United Arab Emirates Tel: +97 148865858/859 • Fax: +97 148865800 E-mail: [email protected] • Website: www.nitinfire.com Certificate No: 018c to EN 54-2: 1997 and EN 54-4: 1997 Certificated Products Discovery NV 2 NV 4 NV 8 20 Oct 2014 4 loop analogue addressable control and indicating equipment Incorporating as modular units: A1579 Motherboard A1580 Display board A1585 Loop cards A1584 230Vac power supply control card A1599 Printer board Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 2 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 4 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment LPCB Ref. No. 018c/01 018c/02 018c/03 018c/04 93 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products NV 16 NV 32 NV 8R NV 16R NV 32R LPCB Ref. No. 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 16 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1629 Display board C1632 16 Zone expansion board C1652 5A Power supply board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 16 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 018c/05 018c/06 018c/R01 018c/R02 018c/R03 Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd) Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888 E-mail: [email protected] • Website: www.notifierfiresystems.co.uk Certificate No: 154g to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products ID3000 ID3002 94 Basic Equipment Kit, (BEK): Modular analogue addressable control and indicating equipment. 020-538 Basic Equipment Kit ID3000, Group 0 020-538-001 ID3000 Basic Equipment Kit, Group 1 020-538-003 ID3000 Basic Equipment Kit, Group 3 020-538-004 ID3000 Basic Equipment Kit, Group 4 020-538-005 ID3000 Basic Equipment Kit, Group 5 Fixed build 2 loop analogue addressable control and indicating equipment. LPCB Ref. No. 154g/01 154g/01 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products ID3004 ID3006 ID3008 LPCB Ref. No. 002-473 ID3002, 2 Loop, PSU3A, Group 0, Red 002-474 ID3002, 2 Loop, PSU3A, Group 0 002-474-001 ID3002, 2 Loop, PSU3A, Group 1 002-474-003 ID3002, 2 Loop, PSU3A, Group 3 002-474-004 ID3002, 2 Loop, PSU3A, Group 4 002-474-005 ID3002, 2 Loop, PSU3A, Group 5 Fixed build 4 loop analogue addressable control and indicating equipment. 020-727 ID3004, 4 Loop, PSU7A, Group 0, LIB 020-728 ID3004, 4 Loop, PSU7A, Group 0, ELIB 020-729 ID3004, 4 Loop, PSU7A, Group 0, LIB, printer 020-730 ID3004, 4 Loop, PSU7A, Group 0, LIB, 64 zone LED Fixed build 6 loop analogue addressable control and indicating equipment. 020-731 ID3006, 6 Loop, PSU7A, Group 0, 2xLIB 020-732 ID3006, 6 Loop, PSU7A, Group 0, 2xELIB 020-733 ID3006, 6 Loop, PSU7A, Group 0, 2xLIB, printer 020-734 ID3006, 6 Loop, PSU7A, Group 0, 2xLIB, 64 zone LED Fixed build 8 loop analogue addressable control and indicating equipment. 020-735 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery Enclosure 020-736 ID3008, 8 Loop, PSU7A, Group 0, 3xELIB, 78Ah Battery Enclosure 020-737 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery Enclosure, Printer 020-738 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery enclosure, printer, 64 Zone LED ID3000 series 154g/01 154g/01 154g/01 Incorporating the following as modular units: Enclosures: 020-472-009 Backbox Kit Standard, Black / Grey 020-473-009 Backbox Kit Extended, Black / Grey 020-474-009 Backbox Kit Extended Deep, Black / Grey 020-475-009 Backbox Kit Double Extended, Black / Grey 020-476-009 Backbox Kit Double Extended Deep, Black / Grey 020-480-009 Cover Kit Main Moulded, Black / Grey 020-481-009 Cover Kit Extended Moulded, Black / Grey 020-508-009 Backbox Extension Standard Assembly Black / Grey 020-509-009 Backbox Extension Deep Assembly Black / Grey 020-513-009 High Security Cover Kit Main, Black / Grey 020-514-009 High Security Cover Kit Extension 020-576 Main Cover, Stainless Steel 020-577 Extension Cover Stainless Steel 020-621-256 Zone Extension Cover, Stainless / Steel 020-621-009 256 Zone Extension Cover, Black / Grey 020-541-009 PSU7A / 78Ah Battery Enclosure Modules: 020-559-001 Zone Extension Chassis Kit 1-64 Zone C/W Display Module020-559002 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588 Notifier Dual Loop Interface Board, (LIB) 020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 020-648 PSU3A 020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-548 PSU7A Status Indication 020-543 Dual Transmission Path / Booster, PSU Interface 020-773 Routing Termination Unit (DEOL) 020-877 Extinguishing Interface Module M221-SI 020-643 ID²net Fibre Optic Interface Kit 020-647 ID²net Network Gateway Module, (NGM) for use in ID3000 Panel ID50 20 Oct 2014 Note 1: Products are available in language variants as follows: Group 0: English and Icelandic, with English manuals Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English and Polish Group 5: English and Cyrillic Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. Single loop analogue addressable control and indicating equipment 154g/02 95 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. ID60 002-455 ID50 Panel Group 0 002-455-001 ID50 Panel Group 1 002-455-003 ID50 Panel Group 3 002-455-004 ID50 Panel Group 4 May also incorporate the following optional modular unit: 002-553 RS485 Communication Kit Single loop analogue addressable control and indicating equipment 154g/03 ID61 002-456 ID60 Panel Group 0 002-456-001 ID60 Panel Group 1 002-456-003 ID60 Panel Group 3 002-456-004 ID60 Panel Group 4 May also incorporate the following optional modular unit: 002-553 RS485 Communication Kit Single loop analogue addressable control and indicating equipment 154g/04 ID62 NFS2-8 2 Zone NFS2-8 4 Zone 96 002-463 ID61 Panel Group 0 002-463-001 ID61 Panel Group 1 002-463-004 ID61 Panel Group 4 002-485-001 ID61 Panel Group 1 (Red) Incorporating the following modular unit: 020-648 PSU3A Kit May also incorporate the following optional modular units: 020-479 RS485 Communication Kit 020-644-009 Printer Kit Single loop analogue addressable control and indicating equipment 002-461 ID62 Panel Group 0 002-461-001 ID62 Panel Group 1 002-461-004 ID62 Panel Group 4 Incorporating the following modular unit: 020-648 PSU3A Kit May also incorporate the following optional modular units: 020-479 RS485 Communication Kit 020-644-009 Printer Kit Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment: Type A 7.10.3 Outputs to fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to Outputs 7.12.2 Dependencies on more than one alarm signal: Type B 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Note: Products are available in various language groups as follows: Group 0: English, Icelandic, French, Italian, Portuguese and Spanish, (shipped with English manuals) Group 1: English, Icelandic, French, Italian, Portuguese and Spanish Group 2: English, Dutch, German, French and Italian Group 3: English, Swedish, Danish, Norwegian and Finnish Group 4: English and Polish 002-477-122 Language region 1, light grey 002-477-129 Language region 1, black & grey 002-477-222 Language region 2, light grey 002-477-229 Language region 2, black & grey 002-477-322 Language region 3, light grey, dual relay 002-477-329 Language region 3, black & grey, dual relay, English manual 002-490-129 Language region 1, black & grey, dual relay, English manual 002-490-229 Language region 2, black & grey, dual relay, English manual 002-490-222 Language region 2, light grey, English manua 002-477-142 Language region 1, light grey 002-477-149 Language region 1, black & grey 002-477-242 Language region 2, light grey 002-477-249 Language region 2, black & grey 002-477-342 Language region 3, light grey, dual relay 002-477-349 Language region 3, black & grey, dual relay 154g/05 154g/06 154g/07 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products NFS2-8 8 Zone LPCB Ref. No. 002-490-149 002-490-249 002-490-242 002-477-182 002-477-189 002-477-282 002-477-289 002-477-382 002-477-389 002-490-189 002-490-289 002-490-282 Language region 1, black & grey, dual relay, English manual Language region 2, black & grey, dual relay, English manual Language region 2, light grey, English manual Language region 1, light grey Language region 1, black & grey Language region 2, light grey Language region 2, black & grey Language region 3, light grey, dual relay Language region 3, black & grey, dual relay Language region 1, black & grey, dual relay, English manual Language region 2, black & grey, dual relay, English manual Language region 2, light grey, English manual 154g/08 Incorporating the following units: 020-747 8-Way relay kit 020-772 4-way monitored sounder kit Certified with the following options from EN 54 Part 2: 7.8 7.9.1 ID2000 ID2002 Output to fire alarm devices Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition Basic Equipment Kit, (BEK): Modular analogue addressable control and indicating equipment. 020-628 Basic equipment kit ID2000 Group 0, 020-628-001Basic equipment kit ID2000 Group 1, UK ES PT IT 020-628-002Basic equipment kit ID2000 Group 2, UK NL FR Fixed build 2 loop analogue addressable control and indicating equipment. 002-459 ID2002, 2 loop control and indicating equipment, Group 1 154g/09 154g/09 Incorporating the following as optional modular units: Enclosures: 020-472-009 020-473-009 020-474-009 020-475-009 020-476-009 020-480-009 020-481-009 020-508-009 020-509-009 020-576 020-577 020-541-009 Modules: 020-649-009 020-708-009 020-644-009 020-588 020-478 020-479 020-648 Backbox Kit Standard, Black / Grey Backbox Kit Extended, Black / Grey Backbox Kit Extended Deep, Black / Grey Backbox Kit Double Extended, Black / Grey Backbox Kit Double Extended Deep, Black / Grey Cover Kit Main Moulded, Black / Grey Cover Kit Extended Moulded, Black / Grey Backbox Extension Standard Assembly Black / Grey Backbox Extension Deep Assembly Black / Grey Main Cover, Stainless Steel Extension Cover Stainless Steel PSU7A / 78Ah Battery Enclosure 64 Zone Extension Chassis Kit 64 Zone C/W Display Module Extension Chassis with Printer Printer Assembly Notifier Dual Loop Interface Board, (LIB) RS232 Interface RS485 Interface PSU3A PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-543 Dual Transmission Path / Booster, PSU Interface 020-548 PSU7A Status Indication Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 20 Oct 2014 97 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 8.3 9.5 10 Fault signals from points Disablements of addressable points Test condition Note: Products are available in language variants as follows: Group 0: English, Spanish, Portuguese and Italian (shipped with English manuals) Pearl Group 1: English, Spanish, Portuguese and Italian Group 2: English, Dutch, and French Two loop analogue addressable control and indicating equipment 154g/10 Incorporating the following units: 124-408 3A PSU board 124-412 Network gateway module 124-421 Base board incorporating two loops 124-422 Display board 124-423 VdS I/O Module 124-426 Communications module PRL Box Extended Back box Incorporating the following optional regional language text inserts: PRL-EN ( English) PRL-D (German) PRL-IB (Iberia) PRL-BNL (Benelux) PRL-NRD (Swedish) PRL-MEA (Middle East and Africa) PRL-IT (Italian) Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.3 7.10.4 7.11 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Notes: 1. 002-467 Output to fire alarm devices Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment type A Output to fire protection equipment type C Fault monitoring of fire protection equipment Delays to outputs Dependency on more than one alarm signal type B Dependency on more than one alarm signal type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablements of addressable points Test condition 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. ID 2 net Network Gateway Unit, (NGU) Notifier Protocol 154g/NO1 Incorporating the following as modular units: 020-643 ID 2 net Fibre Optic Interface Kit 020-647 ID 2 net Network Gateway Module, (NGM) for use in ID3000 Panels 020-648 PSU3A Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 98 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 8.3 8.9 9.5 10 Fault signals from points Output to fault warning routing equipment Disablements of addressable points Test condition Olympia Electronics S.A. Kolindros Pierias, 60061, Greece Tel: (+30) 2353051200 • Fax: (+30 )2353051486 E-mail: [email protected] • Website: www.olympia-electronics.gr Certificate No: 1010a to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2 006 Certificated Products BSR-2104 Two loop analogue addressable control and indicating equipment. LPCB Ref. No. 1010a/01 Incorporating the following units: 1702091 Main board 0905073 Main processor board 0506073 Input / Output Unit 1603073 LED PCB board 2307103 Loop 1 incorporating power control board DPP100-24 Lambda PSU block BSR-2114 Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.10.1 Output to fire protection equipment (Type A) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.13 Alarm counter 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Four loop analogue addressable control and indicating equipment. 1010a/02 Incorporating the following units: 1702091 Main board 0905073 Main processor board 0506073 Input / Output Unit 1603073 LED PCB board 2307103 Loop 1 incorporating power control board 2607103 Loop 2 board DPP100-24 Lambda PSU block Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.10.1 Output to fire protection equipment (Type A) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.13 Alarm counter 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition 20 Oct 2014 99 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Orient Corporation Pte. Ltd. Block 3018, Bedok North Street 5, #05-51, Eastlink Light Industrial Building 486132, Singapore Tel: (+65) 6242 5489 • Fax: (+65) 6241 2291 E-mail: [email protected] Certificate No: 176c-(cl-1) to EN 12094-1: 2003, EN54-2: 1997 + A1: 2006 + A2: 2007 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Control and indicating equipment Certificated Products EP203/ORIENT Conventional three zone class A extinguisher control panel LPCB Ref. No. 176c/01 Incorporating the following units: SPF0000203 SPF0000212 SPF0003613 SPF0000214 Main extinguisher control External relay interface Power supply unit EP214 terminator Incorporating as modular units: EP210S Remote Status Unit Surface Mount optional (See Note 1) EP211 Economy Status Unit optional (See Note 1) Certified with the following options with requirements from EN 12094-1:2003 4.17 4.18 4.19 4.20 4.21 4.23 4.26 4.27 4.30 Delay of extinguishing signal Signal representing the flow of extinguishing agent Monitoring of the status of components Emergency hold device Control of flooding time Manual only mode Triggering of equipment outside the system Emergency abort device Activation of alarm devices with different signals Certified with the following options with requirements from EN 54-2:1997 7.8 7.11 7.13 10 Output to fire alarm device(s) Delays to the auctioning of outputs fire alarm devices and fire routing equipment Alarm counter Test condition Note: 1. Optional Remote Status Unit part No. EP210S & Economy Status Unit part No. EP211 are not certified as meeting the requirements of the standards specified. 2. Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature range of -5°C to +40°C. 100 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Pelco Finland Oy Sokerilinnantie 11C, 02600, Espoo, Finland Tel: +358 10 446 511 • Fax: +358 10 446 5103 E-mail: [email protected] • Website: www.pelco.com/nordic Manufactured at: Pelco Finland Oy, Manttaalitie 5-7, 01530 Vantaa, Finland Certificate No: 883b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products FX 8 Loop Analogue addressable CIE LPCB Ref. No. 883b/01 Basic unit incorporates the following modules: FX-MC2 FX-UI2 FX-PSB or FX-PSA Master controller User interface 4.5 A Power Supply 2.2 A Power Supply Optional Modules -The following modules are optional additions to the basic unit: FX-ALCB Two loop addressable controller - Apollo protocol card FX-ALCA One loop addressable controller - Apollo protocol card FX-LC Two loop addressable controller - System Sensor protocol card FX-SLC Two loop addressable controller - System Sensor advanced protocol card FX-CLC Sixteen loop conventional Controller FX-IOC I/O controller board FX-OCA 16 clean output module FX-LB80 80 Zone LED indication card FX2-LB32 32 Panel LED indication card FX-BAT Separate battery box (4x17Ah, 12V) FXM-BAT Separate battery box (4x12Ah, 12V) Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.10.3 7.11 7.12.2 7.13 8.3 8.4 8.9 9.5 10 FXL Outputs to fire alarm devices Output to fire alarm routing equipment Output to Fire Protection Equipment (Output Type C) Delays to outputs Dependencies on more than one alarm signal (Type B) Alarm counter Fault signals from points Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 8 Loop Analogue addressable CIE 883b/02 Basic unit incorporates the following modules: FX-MC2 FX-UI2 FX-PSB or FX-PSA Master controller User interface 4.5 A Power Supply 2.2 A Power Supply Optional Modules -The following modules are optional additions to the basic unit: FX-ALCB Two loop addressable controller - Apollo protocol card 20 Oct 2014 101 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. FX-ALCA One loop addressable controller - Apollo protocol card FX-LC Two loop addressable controller - System Sensor protocol card FX-SLC Two loop addressable controller - System Sensor advanced protocol card FX-CLC Sixteen loop conventional Controller FX-IOC I/O controller board FX-OCA 16 clean output module FX-LB80 80 Zone LED indication card FX2-LB32 32 Panel LED indication card FX-BAT Separate battery box (4x17Ah, 12V) FXM-BAT Separate battery box (4x12Ah, 12V) Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.10.3 7.11 7.12.2 7.13 8.3 8.4 8.9 9.5 10 FXM Outputs to fire alarm devices Output to fire alarm routing equipment Output to Fire Protection Equipment (Output Type C) Delays to outputs Dependencies on more than one alarm signal (Type B) Alarm counter Fault signals from points Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 4 Loop Analogue addressable CIE 883b/03 Basic unit incorporates the following modules: FX-MC2 FX-UI2 FX-PSB or FX-PSA Master Controller User Interface 4.5 A Power Supply 2.2 A Power Supply Optional Modules -The following modules are optional additions to the basic unit: FX-ALCB Two loop addressable controller - Apollo protocol card FX-ALCA One loop addressable controller - Apollo protocol card FX-LC Two loop addressable controller - System sensor protocol card FX-SLC Two loop addressable controller - System Sensor advanced protocol card FX-CLC Sixteen loop conventional Controller FX-IOC I/O controller board FX-OCA 16 clean output module FX-LB80 80 Zone LED indication card FX2-LB32 32 Panel LED indication card FX-BAT Separate battery box (4x17Ah, 12V) FXM-BAT Separate battery box (4x12Ah, 12V) Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.10.3 7.11 7.12.2 7.13 8.3 8.4 8.9 9.5 10 FXS 102 Outputs to fire alarm devices Output to fire alarm routing equipment Output to Fire Protection Equipment (Output Type C) Delays to outputs Dependencies on more than one alarm signal (Type B) Alarm counter Fault signals from points Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Analogue addressable Repeater Panel 883b/R01 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating the following modules: FX-MC2 FX-UI2 Master Controller User Interface Optional Modules -The following modules are optional additions to the basic unit: FX-IOC I/O Controller Photain Controls 8 New Market Court, Chippenham Drive, Kingston, Milton Keynes MK10 0AQ, United Kingdom Tel: 01908 281981 • Fax: 01908 282554 E-mail: [email protected] Certificate No: 092h to BS EN 54 - 2: 1998 and BS EN 54- 4: 1998 N.B. This certificate is to a withdrawn standard. Control and indicating equipment conforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because controland indicating equipment meeting the withdrawn standard is still requested by some regulators outside of the EU Certificate No: 1199c to EN-2:1997 + A1:2006 EN-4:1997 + A1:2002 Certificated Products System 2000 PAI LPCB Ref. No. 092h/01 System 2000 PAI Incorporating as modular units: ZP3-MB2-4L ZP3-MB2-2L ZP3-MB2-1L ZP3-CPU1 ZP3-DB1 ZP3-ZB50 ZP3-CB1 ZP3-PR1 ZP3AB-SCB-D ZP3AB-RL8 ZP3-AB-MA8 ZP3AB-OP24 ZP3AB-MIP8 ZP3-Xl 4 Loop Main board 2 Loop Main board 1 Loop Main board CPU board Display board 50 Zone LED board Commissioning key switch board Printer Kit Control bus driver Programmable relay output board, 8 way Programmable monitored output board, 8 way Programmable transistor output board, 24 way Programmable input board, 8 way 230Vac Power supply unit Approved with the following options from BS EN54 Part 2: 7.8 7.9 7.10 7.11 7.12 7.13 8.3 8.4 8.9 9.5 10 11 Output to fire alarm devices Output to fire alarm routing equipment Output to fire protection equipment Delays to outputs Co-incidence detection Alarm counter Fault signals from points Total loss of power Output to fault routing equipment Disablement of addressable points Test condition Standardised input/output interface System 2000 PAI 1, 2 and 4 loop analogue addressable control and indicating equipment Incorporating as modular units: ZP3-MB2-4L ZP3-MB2-2L ZP3-MB2-1L ZP3-CPU1 ZP3-DB1 ZP3-ZB50 20 Oct 2014 4 Loop Main board 2 Loop Main board 1 Loop Main board CPU board Display board 50 Zone LED board 103 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT ZP3-CB1 ZP3-PR1 ZP3AB-SCB-D ZP3AB-RL8 ZP3-AB-MA8 ZP3AB-OP24 ZP3AB-MIP8 ZP3-Xl Commissioning key switch board Printer Kit Control bus driver Programmable relay output board, 8 way Programmable monitored output board, 8 way Programmable transistor output board, 24 way Programmable input board, 8 way 230Vac Power supply unit Approved with the following options from BS EN54 Part 2: 7.8 7.9 7.10 7.11 7.12 7.13 8.3 8.4 8.9 9.5 10 11 Output to fire alarm devices Output to fire alarm routing equipment Output to fire protection equipment Delays to outputs Co-incidence detection Alarm counter Fault signals from points Total loss of power Output to fault routing equipment Disablement of addressable points Test condition Standardised input/output interface Protec Fire Detection plc Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom Tel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273 E-mail: [email protected] • Website: www.protec.co.uk Certificate No: 201ad to EN 54-2: 1997+A1: 2006 and EN 54-4: 1997+A1: 2002+A2: 2006 Certificated Products 6304 LPCB Ref. No. 4 Loop Analogue addressable control and indicating equipment 201ad/09 Incorporating the following units: SF41-860-52F SF41-850-50C SF40-877-65 31-100-22 31-243-36 62-407-57 04-701-38 SF40-465-43F SF41-913-56B 31-275-44 SF40-879-67G Main Board Terminal Board CP250 Printer Board Backbox Inner Plate Door Printer Mechanism Series 9000 Power Supply Unit SMT Dual 6000 Loop Card Optional external 24 AH battery box Network Card Certified with the following options with requirements from EN 54: Part 2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Note: 1. Scope of approval does not include the operation of the network functionality. 6400/DCN Display and Control node 201ad/01 Incorporating the following units: 104 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. SF40-855-65E SF40-811-47E SF40-821-49E Display control unit Local display unit PF Terminal unit Certified with the following options with requirements from EN 54: Part 2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Notes: 1. 2. 6400/2LPN This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/2LPN 2 Loop processing node and/or 6400/4LPN 4 Loop processing node 6400/PSU 8A Power supply with charger Scope of approval does not include the operation of the network functionality. 2 Loop processing node 201ad/02 Incorporating the following units: SF40-812-48E SSU SF40-814-50E Local IO SF40-817-53C Terminal board SF40-819-55D 6400 Loop terminal board SF40-818-54 LPN display board SF40-826-54C 6400 OPTO isolated 485 board SF40-913-56B 6400 Loop Transmission board Notes: 1. This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 542 & 4 the unit must be used in conjunction with the following units: 6400/DCN Display and Control node 6400/PSU 8A Power supply with charger 2. Scope of approval does not include the operation of the network functionality. 6400/4LPN 4 Loop processing node 201ad/03 Incorporating the following units: SF40-812-48E SSU SF40-814-50E Local IO SF40-817-53C 5400 Terminal board SF40-819-55D 6400 Loop terminal board SF40-818-54 LPN display board SF40-826-54C 6400 OPTO 485 board SF40-913-56B 6400 Loop Transmission board Notes: 1. This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/DCN Display and Control node 6400/PSU 8A Power supply with charger 2. Scope of approval does not include the operation of the network functionality. 6400/DCN/2LPN 20 Oct 2014 Display and control node plus 2 Loop processing node 201ad/04 105 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating the following units: SF40-855-65E SF40-811-47E SF40-812-48E SF40-814-50E SF40-817-53C SF40-819-55D SF40-826-54C SF40-913-56B Display control unit 5400 LED display unit SSU Local IO 5400 Terminal board 6400 Loop terminal board 6400 OPTO isolated 485 board 6400 Loop Transmission board Certified with the following options with requirements from EN 54: Part 2: 7.8 7.9.1 7.11 7.12.3 7.13 8.3 8.9 9.5 10 Notes: 1. 2. 6400/DCN/4LPN Output to fire alarm device(s) Output to fire alarm routing equipment Delays to outputs Dependencies on more than one alarm signal - Type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of each address point Test condition This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/PSU 8A Power supply with charger Scope of approval does not include the operation of the network functionality. Display and control node plus 4 Loop processing node 201ad/05 Incorporating the following units: SF40-855-65E SF40-811-47E SF40-812-48E SF40-814-50E SF40-817-53C SF40-819-55D SF40-826-54C SF40-913-56B Display control unit 5400 Local display unit SSU Local IO 5400 Terminal board 6400 Loop terminal board 6400 OPTO isolated 485 board 6400 Loop Transmission board Certified with the following options with requirements from EN 54: Part 2: 7.8 7.9.1 7.11 7.12.3 7.13 8.3 8.9 9.5 10 Notes: 1. 2. 6400/PSU Output to fire alarm device(s) Output to fire alarm routing equipment Delays to outputs Dependencies on more than one alarm signal - Type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of each address point Test condition This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/PSU 8A Power supply with charger Scope of approval does not include the operation of the network functionality. 8A Power supply with charger 201ad/06 Incorporating the following units: SF40-472-48H-3 106 8A Power supply with charger 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Notes: 1. 2. 3. 6301 This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/DCN Display and Control node 6400/2LPN 2 Loop processing node and/or 6400/4LPN 4 Loop processing node Scope of approval does not include the operation of the network functionality. Certified to EN 54-4 only. 1 Loop Analogue addressable control and indicating equipment 201ad/07 Incorporating the following units: SF41-860-52F SF41-850-50C SF40-877-65 31-100-22 31-243-36 62-407-57 04-701-38 SF40-465-43F 31-275-44 SF40-879-67G Main Board Terminal Board CP250 Printer Board Backbox Inner Plate Door Printer Mechanism Series 9000 Power Supply Unit Optional external 24 AH battery box Network Card Certified with the following options with requirements from EN 54: Part 2: 6302 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Note: 1. Scope of approval does not include the operation of the network functionality. 2 Loop Analogue addressable control and indicating equipment 201ad/08 Incorporating the following units: SF41-860-52F SF41-850-50C SF40-877-65 31-100-22 31-243-36 62-407-57 04-701-38 SF40-465-43F 31-275-44 SF40-879-67G Main Board Terminal Board CP250 Printer Board Backbox Inner Plate Door Printer Mechanism Series 9000 Power Supply Unit Optional external 24 AH battery box Network Card Certified with the following options with requirements from EN 54: Part 2 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Note: 1. Scope of approval does not include the operation of the network functionality. 20 Oct 2014 107 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificate No: 201af to EN54-4:2002+A2: Control and indicating equipment Certificated Products 9300EN 9800EN 9300EN-7Ah Dual 3 Amp 75W Power Supply with 7Ah batteries 9300EN-12Ah Dual 3 Amp 75W Power Supply with 12Ah batteries 9300EN-18Ah Dual 3 Amp 75W Power Supply with 18Ah batteries 9300EN-24Ah Dual 3 Amp 75W Power Supply with 24Ah batteries 9800EN-24Ah Dual output 8 Amp 200W Power Supply with 24Ah batteries 9800EN-40Ah Dual output 8 Amp 200W Power Supply with 40Ah batteries 9800EN-60Ah Dual output 8 Amp 200W Power Supply with 60Ah batteries LPCB Ref. No. 201af/01 201af/02 Schneider Electric Buildings Sweden AB Dialoggatan 16, 126 37, Hägersten, Norway Tel: +4687752700 • Fax: +4687449802 E-mail: [email protected] • Website: www.schneider-electric.com Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products CFP704-4/SCAN/S Four zone conventional control and indicating equipment LPCB Ref. No. 176b/13 Incorporating the units: RPF0702005 Power supply PCB SPF0724853 4 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition Schneider Electronic Buildings AS Luhrtoppen 2, N-1470, Lørenskog, Norway E-mail: [email protected] • Website: www.schneider-electric.no Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products EPC4 Four zone conventional control and indicating equipment LPCB Ref. No. 176b/13 Incorporating the units: RPF0702005 Power supply PCB SPF0724853 4 Zone main control board Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices(s) 7.11 Delays to outputs 10 Test condition 108 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT SHIELD FIRE, SAFETY AND SECURITY LTD Redburn House, 2a Tonbridge Road, Romford, Essex RM3 8QE, United Kingdom Tel: +44 207 712 1610 • Fax: +44 207 712 1578 E-mail: [email protected] • Website: www.shieldglobal.com Certificate No: 548p-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products P-A2M Intelligent 2 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment LPCB Ref. No. 548p/01 Incorporating the following units: MB-220/ F7.820.826 Main board SB-220/ F7.820.827 Switch board TB-220/ F7.820.828 Loop interface board PS-220/ F7.820.829b Power supply unit ZP-220/ F7.820.312d Zone indication and intervention board LC-A2M/ F7.820.1125 Loop board Incorporating as optional modular units: DB-A300/ F7.820.913a RS-232 board for configuration P-A300P Printer module kit P-A8M Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment 548p/02 Incorporating the following units: SB-800/ F7.820.1238 Indication board LCIFP8/ F7.820.1239 Loop board PB-800/ F7.820.1311 Power board ZP-800/ F7.820.1312 ZCP board KB-800/ F7.820.1326 Keypad board MB-800/ F7.820.1237 Main board MO-800/ F7.820.1310 Mother board Incorporating as optional modular units: P-9935/ F7.820.1313 USB communication board Optional language variants: 10104673 Portuguese language variant 10104675 Hungarian language variant Certified with the following options with requirements from EN 54 Part 2: P-C202A 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.9.2 Alarm confirmation input from fire routing equipment 7.10.1 Output type A 7.10.2 Output type B 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition 2 Zone Conventional Control and Indicating Equipment 548p/03 Incorporating the following modules: FC-102A/ F7.843.399 Membrane CB-102A/ F2.908.1719 Control board with integrated PSE DB-102A/ F2.908.1722 Display board 20 Oct 2014 109 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Optional modules: 10104648 Traditional Chinese text variant CF-102A/ F7.843.421 Membrane P-C204A Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 4 Zone Conventional Control and Indicating Equipment 548p/04 Incorporating the following modules: FC-104A/ F7.843.400 Membrane CB-104A/ F2.908.1718 Control board with integrated PSE DB-104A/ F2.908.1721 Display board Optional modules: 10104649 Traditional Chinese text variant CF-104A/ F7.843.422 Membrane P-C208A Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 8 Zone Conventional Control and Indicating Equipment 548p/05 Incorporating the following modules: FC-108A/ F7.843.401 Membrane CB-108A/ F2.908.1675 Control board with integrated PSE DB-108A/ F2.908.1720 Display board Optional modules: 10104650 Traditional Chinese text variant CF-108A/ F7.843.423 Membrane P-C216A Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 16 Zone Conventional Control and Indicating Equipment 548p/06 Incorporating the following modules: FC-116A/ F7.843.402 Membrane XB-116A/ F2.908.1724 Control board with integrated PSE DB-116A/ F2.908.1676 Display board CB-116A/ F7.820.1677 Expansion board P-A2M/1 Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment 548p/08 Incorporating the following units:MB-220/ F7.820.826 Main board SB-220/ F7.820.827 Switch board TB-220/ F7.820.828 Loop interface board PS-220/ F7.820.829b Power supply unit ZP-220/ F7.820.312d Zone indication and intervention board Incorporating as optional modular units:DB-A300/ F7.820.913a RS-232 board for configuration P-A300P Printer module kit LC-A2M/ F7.820.1125 Loop board (for loop expansion) Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 110 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Note: Can be extended to 2-loop panel by adding LC-A2M Incorporating as optional modular units: Incorporating as optional modular units: DB-A300/ F7.820.913a RS-232 board for configuration P-A300P Printer module kit LC-A2M/ F7.820.1125 Loop board (for loop expansion) Siemens Switzerland Limited, Building Technologies Division International Headquarters, Gubelstrasse 22, CH-6301 Zug, Switzerland Tel: +41 (0) 41 724 24 24 • Fax: +41 (0) 41 724 35 22 Manufacturing at: Volketswil Factory, Industriestrasse 22, CH-8604 Volketswil, Switzerland Tel: +41 1 922 6111 • Fax: +41 1 922 6450 UK Sales: Fire Safety and Security Limited Tel: +44 (0)1734 783703 • Fax: +44 (0)1734 775750 Certificate No: 126h-(cl1) to EN 54-2: 1997 and EN 54-4: 1997 Certificate No: 126aw-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 126aw-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 531q-(cl-1) to EN 54-2:1997 + A1:2006 and EN 54-4:1997 + A1:2002 + A2:2006 Certificate No: 126bs/01 to EN 54-13:2005 Control and indicating equipment Certificated Products FC2020 Control and indicating equipment LPCB Ref. No. 126aw/01 Incorporating as modular units: FCM2028 FP2001-A1 FCI2002-A1 FHA2002-A1 Operating unit 70W Power supply Periphery board (2-Loop) Rear housing and as optional modular units: FCM2029-A2 Operating unit FCM2027 PMI- & mainboard FCM2005-A2 Operating add-on module FCM2006-A2 Operating add-on module (2 LED indicator) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FHA2003-A1 Rear housing (standard) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module FCM2003-C2 Operating unit (incl. FBA-Term.CH) FCM2003-N2 Operating unit (incl. EVAC-Term.NL) FTO2004-C1 PCB compl. FBA-Terminal (CH) FTO2007-N1 PCB compl. EVAC- module (NL) SV 24V-150W 150W Power supply REDUX Redundancy module 20 Oct 2014 111 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition Note: 1) 2) FC2030 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Control and indicating equipment 126aw/02 Incorporating as modular units: FCM2028 SV24V-150W FCI2002-A1 FHA2003-A1 FCA2007-A1 Operating unit 150W Power supply Periphery board (2-Loop) Rear housing Card cage (2 slot) and as optional modular units: FCM2029-A2 Operating unit FCM2027 PMI- & mainboard FCM2007-A2 Operating add-on module (4 LED ind.) FCM2015-D1 Operating add-on (DA ind.) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FCI2007-A1 I/O card (monitored) FCI2009-A1 I/O Card FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module FTO2003-D1 Emergency alarm indicator FCA2006-A1 Connection mod. (Card Cage) FCI2008-A1 I/O card (programmable) FCL2001-A1 Line card (FDnet) FCL2002-A1 Line card (collective) FCL2003-A1 Line card (MS9i) REDUX Redundancy module Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.1 112 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type A (only for MS9i & collective line technology) 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition Note: 1) 2) FC2040 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Control and indicating equipment 126aw/03 Incorporating as modular units; FCM2028 FCM2007-A2 SV24V-150W FCI2004-A1 FHA2003-A1 Operating unit Operating add-on (4 LED ind.) 150W Power supply Periphery board (4-Loop) Rear housing and as optional modular units: FCM2029-A2 Operating unit FCM2027 PMI- & mainboard FCM2005-A2 Operating add-on module FCM2006-A2 Operating add-on module (2 LED indicator) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module FCM2003-C2 Operating unit (incl. FBA-Term.CH) FCM2003-N2 Operating unit (incl. EVAC-Term.NL) FTO2004-C1 PCB compl. FBA-Terminal (CH) FTO2007-N1 PCB compl. EVAC- module (NL) REDUX Redundancy module Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition Note: 1) 2) FC2060 20 Oct 2014 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Control and indicating equipment 126aw/04 113 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating as modular units: FCM2028 SV24V-150W FCI2004-A1 FHA2005-A1 FCA2008-A1 Operating unit 150W Power supply Periphery board (4-Loop) Rear housing Card cage (5 slot) and as optional modular units: FCM2029-A2 Operating unit FCM2027 PMI- & mainboard FCM2007-A2 Operating add-on module (4 LED ind.) FCM2015-D1 Operating add-on (DA ind.) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FCI2009-A1 I/O Card, monitor FCI2007-A1 I/O Card, RT FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module FTO2003-D1 Emergency alarm indicator FCA2006-A1 Connection mod. (Card Cage) FCI2008-A1 I/O card (programmable) FCL2001-A1 Line card (FDnet) FCL2002-A1 Line card (collective) FCL2003-A1 Line card (MS9i) REDUX Redundancy module Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.1 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type A (only for MS9i & collective line technology) Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition Note: 1) 2) FC721 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Control and indicating equipment 126aw/05 Incorporating as modular units: FCM7204-Z3 FP2001-A1 FCI2010-A1 FHA2002-A1 Operating unit 70W Power supply Periphery board (1-Loop) Rear housing and as optional modular units: FCM7205-Y3 FCM7203-H3 114 Operating unit (+ LED Ind.) Operating unit (+ EVAC-Term.) 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. FCM2027 FTO2001-A1 FTO2002-A1 FN2001-A1 FCA2001-A1 FCA2002-A1 PMI- & mainboard Event printer 24 LED indicator (internal) Networking module (See Note 1) Isolated RS232 module Isolated RS485 module Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition Note: 1) 2) FC722 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Control and indicating equipment 126aw/06 Incorporating as modular units: FCM7204-Z3 SV24V/150W FCI2002-A1 FHA2003-A1 Operating unit 150W Power supply Periphery board (2-Loop) Rear housing and as optional modular units: FP2001-A1 70W Power supply FHA2001-A1 Rear housing FCM7205-Y3 Operating unit (+ LED Ind.) FCM7203-H3 Operating unit (+ EVAC-Term.) FCM2027 PMI- & mainboard FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module REDUX Redundancy module Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.2 7.12.3 20 Oct 2014 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C 115 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.13 8.3 8.9 9.5 10 Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition 1) Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Note: 2) FC724 Control and indicating equipment 126aw/07 Incorporating as modular units: FCM7204-Z3 SV24V/150W FCI2004-A1 FHA2003-A1 Operating unit 150W Power supply Periphery board (4-Loop) Rear housing and as optional modular units: FCM7205-Y3 Operating unit (+ LED Ind.) FCM7203-H3 Operating unit (+ EVAC-Term.) FCM2027 PMI- & mainboard FCM2007-A2 Operating add-on module (4 LED ind.) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module REDUX Redundancy module Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition Note: 1) 2) FC726 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Control and indicating equipment 126aw/08 Incorporating as modular units: FCM7204-Z3 SV24V/150W FCI2004-A1 FHA2005-A1 FCA2008-A1 Operating unit 150W Power supply Periphery board (4-Loop) Rear housing Card cage (5 slot) and as optional modular units: 116 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. FCM7205-Y3 FCM2027 FCM2007-A2 FCM2015-DA FTO2001-A1 FCI2003-A1 FTO2002-A1 FN2001-A1 FN2008-A1 FCA2001-A1 FCA2002-A1 FCI2001-D1 FTO2003-D1 FCA2006-A1 FCI2008-A1 FCL2001-A1 FCL2002-A1 FCL2003-A1 REDUX Operating unit (+ LED Ind.) PMI- & mainboard Operating add-on module (4 LED ind.) Operating add-on module (DA ind.) Event printer Loop extension (FDnet) 24 LED indicator (internal) Networking module (See Note 1) Ethernet Switch (See Note 1) Isolated RS232 module Isolated RS485 module Fire brigade periphery module Emergency alarm indicator Connection mod. (Card Cage) I/O card (programmable) Line card (FDnet) Line card (collective) Line card (MS9i) Redundancy module Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing 7.10.1 Output to automatic fire protection equipment Type 7.10.2 Output to automatic fire protection equipment Type 7.10.3 Output to automatic fire protection equipment Type 7.10.4 Fault monitoring of automatic fire protection equipment A B C equipment 7.11 7.12.1 collective line technology) 7.12.2 MS9i line technology) 7.12.3 7.13 8.3 8.9 9.5 10 Delays to outputs Coincidence detection type A (only for MS9i & Coincidence detection type B (only for FDnet & Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition Note: Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. FT2040 Fire detection terminal for use with FC2020, FC2030, FC2040 & FC2060 control and indicating equipment 126aw/R0 1 Incorporating as modular units: FCM2029-A2 FTI2001-A1 FHA2001-A1 Operating unit Fire terminal board Rear housing and as optional modular units: FCM2028 FCM2027 FTO2001-A1 FTO2002-A1 FN2001-A1 FN2008-A1 FCA2001-A1 20 Oct 2014 Operating unit PMI- & mainboard Event printer 24 LED indicator (internal) Networking module (See Note 1) Ethernet Switch (See Note 1) Isolated RS232 module 117 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. FCA2002-A1 Isolated RS485 module FCM2003-C2 Operating unit (incl. FBA-Term.CH) FCM2003-N2 Operating unit (incl. EVAC-Term.NL) FTO2004-C1 PCB compl. FBA-Terminal (CH) FTO2007-N1 PCB compl. EVAC- module (NL) FP2001-A1 70W Power supply H28G200 Housing base REDUX Redundancy module Note: 1) 2) FT724 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Fire detection terminal for use with FC721, FC722 & FC724 control and indicating equipment 126aw/R0 2 Incorporating as modular units: FCM7204-Z3 FTI2001-A1 FHA2001-A1 Operating unit Fire terminal board Rear housing and as optional modular units: FCM7205-Y3 Operating unit (+ LED Ind.) FCM7203-H3 Operating unit (+ EVAC-Term.) FCM2027 PMI- & mainboard FTO2001-A1 Event printer FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FP2001-A1 70W Power supply H28G200 Housing base REDUX Redundancy module Note: 1) 2) CS1140 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Control and indicating equipment Comprising the following products: CC1140 Control and indicating equipment CT11 Operators console CI1140 Integrated central unit Incorporating as modular units: E3X100 Master module 126h/01 E3X102 Master Module E3X103 Master Module E3X120 Master card Cl1145 E3C010 Battery charging module E3C011 Battery charging module B2F020 Converter B2F040 Converter E3M140 Line module FD20 E3M070 Line module "Interactive" E3M071 Line module Interactive K3M140 Line card FD20 K3M071 Line card Interactive to E3X120 K3M080 Line card Collective B3Q460 Control console Algopilot "CT11" B3Q321 Fire department control panel (Swiss) E3G050 Contacts control unit E3G070 Universal control unit E3I020 RS232 unit K3I060 RS232 module E3L020 I/O control unit E3M080 Group line unit 118 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. K3R071 Synoptic - Algo pilot K3R070 Synoptic - Algo pilot K3I050 LON/Synoptic converter E3M060 MS9i module E3G091 Remote TX i/face E3M110 AnalogPLUS module E3M111 Line module AnaloguPLUS K3M111 Line card AnalogPLUS B3R051 Parallel indicator panel (24 x 2 LED) E3G080 Control module Extinguishing B3Q440 Control console Extinguishing module E3G060 Control monitored module E3H020 C-Bus Gateway module E3I040 I-Bus/LON module B3Q560/B3Q600 Terminals China B3Q580 Text display terminal B3Q590 Text control terminal Nordic B3Q660 Operator console Standard Algopilot "CT11" B3Q661 Operator console Standard Algopilot "CT11" B3Q680 Control console Nordic Algopilot "CT11" B3Q565 Operator control Asia Pacific Algopilot "CT11" K3N010 RAM - Extension K3I110 LON Input/Output Box E3M171 Line Module Ex Interactive K5L020 Multi-Sect. Extinguishing P.C.B K3G060 Relay Card to Synptic BUS E3G100 Emergency Operation Link E3G110 Emergency Link to E3G080 K3R072 Synoptical Driver M3C080 Horn Monitoring Module Certified with the following Options with requirements from EN 54-2:1997 7.8 Outputs to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.4 Complete failure of power supply 9.5 Disablement of addressable points 10 Test condition 11 Standardised input/output interface FC121-ZA , FC122-ZA Notes: 1) Compliance with clause 12.6.2 of EN 54-2:1997 requires LCD screen saving feature to be disabled for the alarm condition. Two zone conventional control and indicating equipment Four zone conventional control and indicating equipment 531q/01 Incorporating the units: PCBA FC121-ZA Two zone main control board with integrated power supply PCBA FC122-ZA Four zone main control board with integrated power supply Optional modules: FCA1203-Z1 Output card 2M2R FTO1201-H1 EVAC module (applicable on NL model only) FCA1206-Z1 Key switch set ( applicable on Nordic SE model only) FC123-ZA , FC124-ZA 20 Oct 2014 Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.13 Alarm counter 8.9 Output to fault warning routing equipment 10 Test condition Eight zone conventional control and indicating equipment Twelve zone conventional control and indicating equipment 531q/02 119 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating the units: PCBA FC123-ZA Eight zone main control board PCBA FC124-ZA Twelve zone main control board FP2015-A1 Power supply (70W) Optional modules: FCA1203-Z1 Output card 2M2R FTO1202-Z1 Zone indication field 12x2 LED FTO1203-H1 EVAC module (applicable on NL model only) FCA1206-Z1 Key switch set (applicable on Nordic SE model only) Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.13 Alarm counter 8.9 Output to fault warning routing equipment 10 Test condition Note: This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 1 0 / s b 6 2 1 t n e m p i u q e g n i t a c i d n i d n a l o r t n o c l a n o i t n e v n o c e n o z o w T A Z 1 2 1 C F t n e m p i u q e g n i t a c i d n i d n a l o r t n o c l a n o i t n e v n o c e n o z r u o F A Z 2 2 1 C F t n e m p i u q e g n i t a c i d n i d n a l o r t n o c l a n o i t n e v n o c e n o z t h g i E A Z 3 2 1 C F t n e m p i u q e g n i t a c i d n i d n a l o r t n o c l a n o i t n e v n o c e n o z e v l e w T A Z 4 2 1 C F y l p p u S r e w o P y l p p u s r e w o p l a n r e t n i E I C 1 A 5 1 0 2 P F e c i v e D t u p t u O e l u d o M t u p t u O 1 Z 9 0 2 1 A C F e c i v e D t u p t u O / t u p n I r o t a l o s i t i u c r i c t r o h s h t i w e l u d o m t u p t u o / t u p n I 2 9 1 1 C D s r o t c e t e D l a i c r e m m o C r o t a l o s i t i u c r i c t r o h s h t i w r o t c e t e d r o s n e s i t l u m e l b a s s e r d d a e u g o l a n A 9 1 4 2 T O O D F r o t a l o s i t i u c r i c t r o h s h t i w r o t c e t e d r o s n e s i t l u M 9 A 1 4 2 T O O D F r o t a l o s i t i u c r i c t r o h s h t i w r o t c e t e d m a e b e l b a s s e r d d a e u g o l a n A 9 1 4 2 L D F t n e m e c n a h n e l a m r e h t h t i w r o t c e t e d e k o m s c i r t c e l e o t o h p l a n o i t n e v n o C C 0 2 3 H O r o t a l o s i t i u c r i c t r o h s h t i w r o t c e t e d r o s n e s i t l u m e l b a s s e r d d a e u g o l a n A 0 4 7 H O O r o t c e t e d e k o m s c i r t c e l e o t o h p l a n o i t n e v n o c e f a s y l l a c i s n i r t n I x E A 1 0 1 1 O D r o t c e t e d t a e h R 1 A s s a l c l a n o i t n e v n o C A 1 0 1 1 T D r o t c e t e d t a e h R 1 A s s a l c e f a s y l l a c i s n i r t n i l a n o i t n e v n o C x E A 1 0 1 1 T D r o t c e t e d t a e h B s s a l c l a n o i t n e v n o C A 2 0 1 1 T D 120 20 Oct 2014 CONTROL AND INDICATING EQUIPMENT PART 1: SECTION 3 r o t c e t e d t a e h B s s a l c e f a s y l l a c i s n i r t n i l a n o i t n e v n o C x E A 2 0 1 1 T D r o t c e t e d e k o m s c i r t c e l e o t o h p l a n o i t n e v n o C A 1 0 1 1 O D r o t c e t e d t a e h R 1 A s s a l c l a n o i t n e v n o C C 0 2 3 I H r o t c e t e d t a e h 2 A s s a l c l a n o i t n e v n o C C 2 2 3 I H r o t c e t e d e k o m s c i r t c e l e o t o h p l a n o i t n e v n o C C 0 2 3 P O s r o t c e t e D e m a l F r o t a l o s i t i u c r i c t r o h s h t i w r o t c e t e d e m a l f d e r a r f n i e l b a s s e r d d a e u g o l a n A 9 1 2 2 F D F r o t a l o s i t i u c r i c t r o h s h t i w r o t c e t e d e m a l f d e r a r f n i e l b a s s e r d d a e u g o l a n A 9 1 4 2 F D F r o t a l o s i t i u c r i c t r o h s h t i w r o t c e t e d e m a l f d e r a r f n i e l b a s s e r d d a e u g o l a n A 1 9 1 1 F D r o t c e t e D e m a l F d e R a r f n I e l b a s s e r d d A e u g o l a n A 2 9 1 1 F D s t n i o P l l a C l a u n a M d e t n u o m h s u l f , t n i o p l l a c l a u n a m r o o d n I 1 0 1 1 M D t n i o p l l a c l a u n a m r o o d t u o d n a r o o d n i l a n o i t n e v n o C 4 0 1 1 M D t n i o p l l a c l a u n a m r o o d t u o d n a r o o d n i l a n o i t n e v n o C C 0 2 3 T M t n e m e l E s s a l G e l b a t t e s e R n o N h t i w t n i o P l l a C l a u n a M r o o d t u O / r o o d n I A e p y T e v i t c e l l o C G R 1 0 1 1 M D F t n e m e l E c i t s a l P e l b a t t e s e R h t i w t n i o P l l a C l a u n a M r o o d t u O / r o o d n I A e p y T e v i t c e l l o C P R 1 0 1 1 M D F t n e m e l E s s a l G e l b a t t e s e R n o N h t i w t n i o P l l a C l a u n a M r o o d t u O / r o o d n I A e p y T l a n o i t n e v n o C G R A 1 0 1 1 M D F t n e m e l E c i t s a l P e l b a t t e s e R h t i w t n i o P l l a C l a u n a M r o o d t u O / r o o d n I A e p y T l a n o i t n e v n o C P R A 1 0 1 1 M D F t n e m e l E s s a l G e l b a t t e s e R n o N h t i w t n i o P l l a C l a u n a M r o o d t u O / r o o d n I A e p y T e v i t c e l l o C ) F ( G R 1 0 1 1 M D F e l b a t t e s e R h t i w t n i o P l l a C l a u n a M r o o d t u O / r o o d n I A e p y T e v i t c e l l o C ) F ( P R 1 0 1 1 M D F . t n e m e l E c i t s a l P e l b a t t e s e R n o g n i l l e b a l h c n e r F ; t n e m e l E c i t s a l P s e c i v e D g n i n r a W m r a l A e s a b r e d n u o s ) e v i t c e l l o c ( l a n o i t n e v n o c e u g o l a n A 2 9 2 B S D F r e d n u o S P L B / A e p y T l a n o i t n e v n o C i n h s o R P L O R : e t o n l a r e n e G l e d o m o t r e f e r , c t e s e n o t r e d n u o s , n o i t a c i f i s s a l c t a e h , s e i t i v i t i s n e s d e v o r p p a g n i d u l c n i t c u d o r p l a u d i v i d n i h c a e n o n o i t a m r o f n i r e h t r u f r o F m o c . e v i l k o o b d e r . w w w n o r o k o o B d e R e h t f o n o i t c e s e t a i r p o r p p a e h t n i ) s ( r e b m u n e c n e r e f e r SMS (Novar Systems Ltd) Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2100 • Fax: +44 (0)116 246 2016 Website: www.smsfire.co.uk Certificate No: 042bc to EN 54-2: 1997+ A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 121 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products Sentri1 LPCB Ref. No. 042bc/01 Single loop analogue addressable control and indicating equipment Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface) Certified with the following options with requirements from EN 54 Part 2: Sentri1-SP 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition Single loop analogue addressable control and indicating equipment (Spanish language variant) Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface) 042bc/02 Certified with the following options with requirements from EN 54 Part 2: Sentri1-PO 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition Single loop analogue addressable control and indicating equipment (Portuguese language variant) Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface) 042bc/03 Certified with the following options with requirements from EN 54 Part 2: Sentri2 Sentri2-PO Sentri2-SP 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition Two loop analogue addressable control and indicating equipment (English language) Two loop analogue addressable control and indicating equipment (Portuguese language variant) Two loop analogue addressable con(Spanish language variant) control and indicating equipment Incorporating as modular units: 042bc/04 042bc/05 042bc/06 2434-859 Master Controller Board (MCB) 2434-862 Power Supply Unit 2434-762 Display and Key card (DKC) 2434-669 Loop processor card 4374-164 Text Membrane (English) 4374-169 Text Membrane (Spanish) 4374-170 Text Membrane (Portuguese) 2434-861 Copper network card Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54 Part 2: Sentri4 Sentri4-PO Sentri4-SP 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Four loop analogue addressable control and indicating equipment (English language) One to Four loop analogue addressable control and indicating equipment (Portuguese language variant without printer module) One to Four loop analogue addressable control and indicating equipment (Spanish language variant without printer module) Incorporating as modular units 2434-863 2434-710 122 042bc/07 042bc/09 042bc/10 Master controller card (M.C.C) Loop card 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer Module 4374-167 Text Membrane (English) 4374-171 Text Membrane (Spanish) 4374-172 Text Membrane (Portuguese) 2434-674 Copper network card Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54 Part 2: 7.8 7.11 8.3 9.5 10 Output to fire alarm devices Delays to outputs Fault signals from points Disablement of each address point Test condition Thorn Security Limited, Trading as Tyco Safety Product Hanworth Road, Sunbury on Thames, London TW16 5DB, United Kingdom Tel: 01932 743268 • Fax: 01932 743292 E-mail: [email protected] • Website: www.Tycoemea.com Certificate No: 018c-(cl-3) to EN54-2: 1997, EN54-4: 1997 Certificate No: 681an-(cl-1) to EN 54-2: 1997 + A1: 006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 681am-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 681ak-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 681aj-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 681ah-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 681ap-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 681af-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 681ea-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 681ac-(cl-2) to EN 54-4: 1997 + A1: 2002 + A2: 2006 Control & Indicating Equipment Certificated Products 2 zone conventional control and indicating equipment LPCB Ref. No. 018c/02 Incorporating as modular units: MZXC+ C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 4 zone conventional control and indicating equipment 018c/03 Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 20 Oct 2014 123 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products MZXC+ 8 zone conventional control and indicating equipment LPCB Ref. No. 018c/04 Incorporating as modular units: MZXC+ C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 16 zone conventional control and indicating equipment 018c/05 Incorporating as modular units: MZXC+ C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 32 zone conventional control and indicating equipment 018c/06 Incorporating as modular units: MZXC+ C1627 Mother board C1629 Display board C1632 16 Zone expansion board C1652 5A Power Supply board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit 018c/R01 Incorporating as modular units: MZXC+ C1627 Mother board C1628 Display board C1631 Repeater interface 16 zone conventional repeater unit 018c/R02 Incorporating as modular units: MZXC+ C1627 Mother board C1628 Display board C1631 Repeater interface 32 zone conventional repeater unit 018c/R03 Incorporating as modular units: 508.031.005.xx C1627 Mother board C1629 Display board C1631 Repeater interface MZXC 4 zone conventional control and indicating equipment. 018q/03 Incorporating as modular units: C1694 - 2605503, 4 Zone Motherboard BAQ-35T24 Power Supply Certified with the following options with requirements from EN 54-2: 124 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.8 7.9.1 7.12.1 7.13 10 Output to fire alarm devices Output to fire alarm routing equipment Dependencies on more than one alarm signal - Type A Alarm counter Test condition Note: 508.031.006.xx xx indicates the language option Blank = Blank facia overlay MZXC 8 zone conventional control and indicating equipment. 018q/04 Incorporating as modular units: C1694 - 2605504, 8 Zone Motherboard BAQ-35T24 Power Supply Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition Note: 508.031.016.xx PSU A17 PSU A38 508.031.004.xx xx indicates the language option Blank = Blank facia overlay Fire alarm repeater (mains). Incorporating as modular units: C1694 2605505, Repeater Motherboard BAQ-35T24 Power Supply Notes: 1. Compatible with 508.031.005.xx & 508.031.006.xx panels. 2. Also compatible with 508.031.005.xx & 508.031.006.xx twin wire conventional panels on certificate 018r. 3. xx indicates the language option Blank = Blank facia overlay EG = English facia overlay Addressable 17Ah Power Supply Unit Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels 2. The maximum lead length for the fault output connection is 3m Addressable 38Ah Power Supply Unit Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels 2. The maximum lead length for the fault output connection is 3m MZXC 2 zone, twin wire conventional control and indicating equipment. 018q/R01 681ac/01 681ac/02 681ae/01 Incorporating as modular units: C1694 - 2605508, 2 Zone Twin Wire Motherboard BAQ-35T24, Power Supply Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition Note: 508.031.005.xx xx indicates the language option EG = English facia overlay MZXC 4 zone, twin wire conventional control and indicating equipment. 681ae/02 Incorporating as modular units: C1694 - 2605509, 4 Zone Twin Wire Motherboard BAQ-35T24, Power Supply Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition Note: 20 Oct 2014 xx indicates the language option 125 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products 508.031.006.xx LPCB Ref. No. EG = English facia overlay MZXC 8 zone twin wire conventional control and indicating equipment. 681ae/03 Incorporating as modular units: C1694 - 2605510, 8 Zone Twin Wire Motherboard BAQ-35T24 Power Supply Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition Note: T2000CV xx indicates the language option EG = English facia overlay 3 loop Analogue Addressable Control and Indicating Equipment Notes: 1. The following product variants are approved Finished goods No. 557.200.620, T2000CV 3 loop CIE Finished goods No. 557.200.605, T2000-BB battery box 681ah/01 Incorporating as modular units: OCM800 ODM800 CPU800 XLM800 FIM802 PSU830 Operator Control Module Operator Display Module Main CPU module Expansion Loop Module “drives 1 or 2 additional loops” Field Interface Module “drives 1 or 2 loops” Power Supply Module and as optional modular units: ANN840 ANN880 COM820 MPM800 IOB800 FB800 40 + 40 LED Annunciator module 80 LED Annunciator module 20 way Status Command Module Multi Purpose Interface Module Input/Output Expansion Board Fuse Board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface T2000R Repeater panel is approved for use with the T2000CV Control and Indicating Equipment (LPCB Reference 018j/R01): Notes: The following product variants are approved Finished goods No. 557.200.601, T2000R (AC) repeater stainless housing Finished goods No. 557.200.604, T2000R (DC) repeater stainless housing Finished goods No. 557.200.611, T2000R (AC) repeater mild steel housing Finished goods No. 557.200.612, T2000R (DC) repeater mild steel housing Incorporating as modular units: OCM800 126 (Operator Control Module) 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. ODM800 PSU830 (Operator Display Module) (Power Supply Module) and as optional modular units: T2000R ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) Repeater panel is approved for use with the T2000CV Control and Indicating Equipment Notes: 1. The following product variants are approved Finished goods No. 557.200.601, T2000R (AC) repeater stainless housing Finished goods No. 557.200.604, T2000R (DC) repeater stainless housing Finished goods No. 557.200.611, T2000R (AC) repeater mild steel housing Finished goods No. 557.200.612, T2000R (DC) repeater mild steel housing 681ah/R01 Incorporating as modular units: OCM800 (Operator Control Module) ODM800 (Operator Display Module) PSU830 (Power Supply Module) and as optional modular units: T2000 ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) 2-8 loop Analogue Addressable Control and Indicating Equipment Notes: 1. The following product variants are approved Finished goods No. 557.200.600, T2000 2-8 loop CIE, stainless housing Finished goods No. 557.200.602, T2000-BB battery box, stainless housing Finished goods No. 557.200.610, T2000 2-8 loop CIE, mild steel housing Finished goods No. 557.200.605, T2000-BB battery box, mild steel housing 681aj/01 Incorporating as modular units: OCM800 ODM800 CPU800 FIM802 PSU830 Operator Control Module Operator Display Module Main CPU module Field Interface Module drives 1 or 2 loops Power Supply Module and as optional modular units: XLM800 ANN840 ANN880 COM820 MPM800 IOB800 FB800 Expansion Loop Module drives 1 or 2 additional loops 40 + 40 LED Annunciator module 80 LED Annunciator module 20 way Status Command Module Multi Purpose Interface Module Input/Output Expansion Board Fuse Board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 20 Oct 2014 127 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 9.5 10 11 Disablement of addressable points Test condition Standardized input/output interface T2000R Repeater panel is approved for use with the T2000CV Control and Indicating Equipment (LPCB Reference 018j/R01): Notes 1. The following product variants are approved Finished goods No. 557.200.601, T2000R (AC) repeater stainless housing Finished goods No. 557.200.604, T2000R (DC) repeater stainless housing Finished goods No. 557.200.611, T2000R (AC) repeater mild steel housing Finished goods No. 557.200.612, T2000R (DC) repeater mild steel housing Incorporating as modular units: OCM800 (Operator Control Module) ODM800 (Operator Display Module) PSU830 (Power Supply Module) and as optional modular units: T2000R ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) Repeater panel is approved for use with the T2000 Control and Indicating Equipment: Notes: 1. The following product variants are approved Finished goods No. 557.200.601, T2000R (AC) repeater stainless housing Finished goods No. 557.200.604, T2000R (DC) repeater stainless housing Finished goods No. 557.200.611, T2000R (AC) repeater mild steel housing Finished goods No. 557.200.612, T2000R (DC) repeater mild steel housing 681aj/R01 Incorporating as modular units: OCM800 (Operator Control Module) ODM800 (Operator Display Module) PSU830 (Power Supply Module) and as optional modular units: MX2 ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) 1-8 loop Analogue Addressable Control and Indicating Equipment Notes: 1. The following product variants are approved Finished goods No. 557.200.203, MX2-210 1-4 loop CIE, shallow housing Finished goods No. 557.200.205, MX2-211, 1-8 loop CIE, deep housing 681ak/01 Incorporating as modular units: DCM800 CPU800 FIM802 PSU830 Operator Control / Display Module Main CPU module Field Interface Module drives 1 or 2 loops Power Supply Module and as optional modular units: XLM800 ANN881 MPM800 FB800 Expansion Loop Module drives 1 or 2 additional loops 80 LED Annunciator module Multi Purpose Interface Module Fuse Board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 128 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products MXR LPCB Ref. No. 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Repeater panel is approved for use with the MX2 Control and Indicating Equipment Notes: 1. The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing Finished goods No. 557.200.012, MXR repeater Finished goods No. 557.200.017, MXR-F repeater flush housing 681ak/R01 Incorporating as modular units: OCM800 (Operator Control Module) ODM800 (Operator Display Module) PSU830 (Power Supply Module) and as optional modular units: ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) 1 loop Analogue Addressable Control and Indicating Equipment Note: 1. The following product variants are approved Finished goods No. 557.200.001, MX1000 1 loop CIE, shallow housing Finished goods No. 557.200.005, MX-BBX battery box, shallow housing Finished goods No. 557.200.002, MX1000 1 loop CIE, deep housing Finished goods No. 557.200.019, MX-BBX-F battery box, flush housing 681am/01 Incorporating as modular units: OCM800 ODM800 CPU800 FIM801 PSU830 Operator Control Module Operator Display Module Main CPU module Field Interface Module Power Supply Module and as optional modular units: ANN840 ANN880 COM820 MPM800 IOB800 FB800 40 + 40 LED Annunciator module 80 LED Annunciator module 20 way Status Command Module Multi Purpose Interface Module Input/Output Expansion Board Fuse Board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 20 Oct 2014 129 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.13 8.3 8.9 9.5 10 11 Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition Standardized input/output interface MXR Repeater panel is approved for use with the MX1000 Control and Indicating Equipment (LPCB Reference 018f/R01): Note: 1. The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing Finished goods No. 557.200.012, MXR repeater Finished goods No. 557.200.017, MXR-F repeater flush housing Incorporating as modular units: OCM800 (Operator Control Module) ODM800 (Operator Display Module) PSU830 (Power Supply Module) and as optional modular units: MXR ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) Repeater panel is approved for use with the MX1000 Control and Indicating Equipment 681am/R0 1 Notes: 1) The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing Finished goods No. 557.200.012, MXR repeater Finished goods No. 557.200.017, MXR-F repeater flush housing Incorporating as modular units: OCM800 ODM800 PSU830 (Operator Control Module) (Operator Display Module) (Power Supply Module) and as optional modular units: MX4000 2-8 ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) 2-8 loop Analogue Addressable Control and Indicating Equipment Note: 1. The following product variants are approved Finished goods No. 557.200.003, MX4000 1-4 loop CIE, shallow housing Finished goods No. 557.200.005, MX-BBX battery box, shallow housing Finished goods No. 557.200.004, MX4000 1-8 loop CIE, deep housing Finished goods No. 557.200.006, MX-DPBX battery box, deep housing (door access) Finished goods No. 557.200.016, MX-DPBX battery box, deep housing (plain cover access) Finished goods No. 557.200.009, MX4000 1-4 loop, flush housing Finished goods No. 557.200.019, MX-BBX-F battery box, flush housing 681an/01 Incorporating as modular units: OCM800 ODM800 CPU800 FIM802 PSU830 130 Operator Control Module Operator Display Module Main CPU module Field Interface Module drives 1 or 2 loops Power Supply Module 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. and as optional modular units: XLM800 ANN840 ANN880 COM820 MPM800 IOB800 FB800 MXR Expansion Loop Module drives 1 or 2 additional loops 40 + 40 LED Annunciator module 80 LED Annunciator module 20 way Status Command Module Multi Purpose Interface Module Input/Output Expansion Board Fuse Board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Repeater panel is approved for use with the MX4000 Control and Indicating Equipment: Note: 1. The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing Finished goods No. 557.200.012, MXR repeater Finished goods No. 557.200.017, MXR-F repeater flush housing 681an/R01 Incorporating as modular units: OCM800 (Operator Control Module) ODM800 (Operator Display Module) PSU830 (Power Supply Module) and as optional modular units: MXR ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) Repeater panel is approved for use with the MX2 Control and Indicating Equipment (LPCB Reference 018f/R01): Notes: 1) The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing Finished goods No. 557.200.012, MXR repeater Finished goods No. 557.200.017, MXR-F repeater flush housing 681an/R01 Incorporating as modular units: OCM800 ODM800 PSU830 (Operator Control Module) (Operator Display Module) (Power Supply Module) and as optional modular units: MZX-125 20 Oct 2014 ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) Analogue Addressable Control and Indicating Equipment 681ap/01 131 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 1 loop, 16 Zone Incorporating as modular units: DCM816 CPU800 FIM801 PMM800 BAQ60T24 MZX-250 Operator Control / Display Module Main CPU module Field Interface Module Power Supply Monitor Power Supply Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 1 loop, 32 Zone 681ap/02 Incorporating as modular units: DCM832 CPU800 FIM802 PMM800 BAQ140T24 Operator Control / Display Module Main CPU module Field Interface Module (1 loop version Part No. 2605053) Power Supply Monitor Power Supply and as an optional modular unit: IOB800 MZX-251 Input/Output Expansion Board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 1 loop, 32 Zone 681ap/03 Incorporating as modular units: DCM832 CPU800 FIM802 PMM800 BAQ140T24 132 Operator Control / Display Module Main CPU module Field Interface Module (1 loop version Part No. 2605053) Power Supply Monitor Power Supply 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. and as an optional modular unit: IOB800 MZX-250-CH Input/Output Expansion Board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 1 loop, 32 Zone 681ap/04 Incorporating as modular units: DCM832 CPU800 FIM802 PMM800 FBF-CH BAQ140T24 Operator Control / Display Module Main CPU module Field Interface Module (1 loop version Part No. 2605053) Power Supply Monitor Swiss Fire Brigade Interface Power Supply and as an optional modular unit: IOB800 MZX-251-S Input/Output Expansion Board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 1 loop, 32 Zone 681ap/05 Incorporating as modular units: DCM832 -S Operator Control / Display Module (Scandinavian Fire Brigade Interface/key) CPU800 Main CPU module FIM802 Field Interface Module (1 loop version Part No. 2605053) PMM800 Power Supply Monitor BAQ140T24 Power Supply and as an optional modular unit: IOB800 20 Oct 2014 Input/Output Expansion Board 133 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products MZX-252 LPCB Ref. No. Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 2 loop, 32 Zone 681ap/06 Incorporating as modular units: DCM832 CPU800 FIM802 PMM800 BAQ140T24 Operator Control / Display Module Main CPU module Field Interface Module Power Supply Monitor Power Supply and as an optional modular unit: IOB800 MZX-252-CH Input/Output Expansion Board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 2 loop, 32 Zone 681ap/07 Incorporating as modular units: DCM832 CPU800 FIM802 PMM800 FBF-CH BAQ140T24 Operator Control / Display Module Main CPU module Field Interface Module Power Supply Monitor Swiss Fire Brigade Interface Power Supply and as an optional modular unit: IOB800 Input/Output Expansion Board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 134 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products MZX-253 LPCB Ref. No. 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 2-4 loop, 64 Zone Incorporating as modular units: 681ap/08 DCM864R Operator Control / Display Module CPU800 Main CPU module FIM802 Field Interface Module PMM800 Power Supply Monitor BAQ140T24 Power Supply and as optional modular units: IOB800 Input/Output Expansion Board PMM840 Power Supply Monitor XLM800 Loop Expander Board MZX-254 Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 2-4 loop, 240 Zone Incorporating as modular units: 681ap/09 DCM832 Operator Control / Display Module CPU800 Main CPU module FIM802 Field Interface Module PMM800 Power Supply Monitor BAQ140T24 Power Supply and as optional modular units: IOB800 Input/Output Expansion Board PMM840 Power Supply Monitor XLM800 Loop Expander Board Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 20 Oct 2014 135 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products MZX-254-S LPCB Ref. No. 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 2-4 loop, 240 Zone Incorporating as modular units: DCM832-S Interface/key) CPU800 FIM802 PMM800 BAQ140T24 681ap/10 Operator Control / Display Module (Scandinavian Fire Brigade Main CPU module Field Interface Module Power Supply Monitor Power Supply and as optional modular units: IOB800 Input/Output Expansion Board PMM840 Power Supply Monitor XLM800 Loop Expander Board MZX-254-CH Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 2-4 loop, 240 Zone Incorporating as modular units: DCM832 CPU800 FIM802 PMM800 FBF-CH BAQ140T24 681ap/11 Operator Control / Display Module Main CPU module Field Interface Module Power Supply Monitor Swiss Fire Brigade Interface Power Supply and as optional modular units: IOB800 Input/Output Expansion Board PMM840 Power Supply Monitor XLM800 Loop Expander Board Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 136 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products MZX-16-R LPCB Ref. No. 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface 16 Zone Repeater Panel, is approved for use with the MZX-125 Control and Indicating Equipment 681ap/R01 Incorporating as modular units: MZX-32-R DCM816 Operator Control / Display Module PMM800 Power Supply Monitor BAQ60T24 Power Supply 32 Zone Repeater Panel, is approved for use with the MZX-250, MZX-250-CH, MZX-251, MZX-252 & MZX-252-CH Control and Indicating Equipment 681ap/R02 Incorporating as modular units: MZX-32-SR DCM832 Operator Control / Display Module PMM800 Power Supply Monitor BAQ60T24 Power Supply 32 Zone Repeater Panel, is approved for use with the MZX-251-S Control and Indicating Equipment 681ap/R03 Incorporating as modular units: MZX-64-DR MZX-DR MZX-SDR MZX-CHDR DCM832-S Operator Control / Display Module PMM800 Power Supply Monitor BAQ60T24 Power Supply 64 Zone Repeater Panel, is approved for use with the MZX-253 Control and Indicating Equipment Incorporating as modular units: DCM832R Operator Control / Display Module PMM805 Power Supply Monitor (24 VDC) 240 Zone Repeater Panel, is approved for use with the MZX-254 Control and Indicating Equipment Incorporating as modular units: DCM832 Operator Control / Display Module PMM805 Power Supply Monitor (24 VDC) 240 Zone Repeater Panel, is approved for use with the MZX254-S Control and Indicating Equipment Incorporating as modular units: DCM832 -S Operator Control / Display Module (Scandinavian Fire Brigade Interface/key) PMM805 Power Supply Monitor (24 VDC) 240 Zone Repeater Panel, is approved for use with the MZX-254-CH Control and Indicating Equipment 681ap/R04 681ap/R05 681ap/R06 681ap/R07 Incorporating as modular units: DCM832 Operator Control / Display Module FBF-CH Swiss Fire Brigade Interface PMM805 Power Supply Monitor (24 VDC) UTC CCS Manufacturing Polska, Sp. Zo.o ul. Kolejowa 24, Ropczyce 39100, Poland E-mail: [email protected] Certificate No: 1199a-(cl-1) to EN 54-2:1997 + A1:2006 , EN54-4:1997+ A1:2002 +A2:2006 and EN54-21:2006 Certificate No: 1199b-(cl-1) to EN54-2:1997+A1:2006 EN54-2:1997+A1:2006 + A2:2006 Certificate No: 1199c/01 to EN 54-4:1998 EN-54-2:1998 Control and indicating equipment Certificated Products KFP-AF1, KFP-AF1-S 20 Oct 2014 Intelligent Analogue Addressable Fire Panel with user interface - 1 loop LPCB Ref. No. 1199a/05 137 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Intelligent Analogue Addressable Fire Panel with user interface - 1 loop small cabinet Incorporating the following units: 2010-2F1-MB KFP-A-UI 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: ZP2-F1-S, ZP2-F1 KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface - 1 loop Intelligent Analogue Addressable Fire Panel with user interface - 1 loop small cabinet 1199a/05 Incorporating the following units: 2010-2F1-MB ZP2-UI 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: 2X-F1-SC, 2X-F1-SC-S ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-TP Translucent door option for large cabinet* ZP2-D-TP-S Translucent door option for small cabinet* Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop small cabinet (Scandinavia) 1199a/06 Incorporating the following units: 2010-2F1-MB Main control board 2X-UI-SC User interface control board 2010-2-PS-40 4A Power Supply And as optional modules: 2X-ZI-20 2X-ZI-40 2010-2-NB 2X-LB 2010-2-232-KIT 2010-SK 2010-2-PS-C2 2010-2-PS-C2-S 138 (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) Network card Loop Board (Large cabinet variant only) Interface board for external printer Scandinavian key and lock assembly UK mains cable for large cabinet UK mains cable for small cabinet 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products KFP-AF1-SC, KFP-AF1SC-S LPCB Ref. No. 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop small cabinet (Scandinavia) 1199a/06 Incorporating the following units: 2010-2F1-MB KFP-A-UI-SC 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: KFP-A-ZI-20 KFP-A-ZI-40 2010-2-NB KFP-A-LB 2010-2-232-KIT 2010-SK 2010-2-PS-C2 2010-2-PS-C2-S 2010-2-PIB-8O 2010-2-PIB-8I only) 2010-2-PIB-8I8O ZP2-F1-SC, ZP2-F1-SC-S (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) Network card Loop Board (Large cabinet variant only) Interface board for external printer Scandinavian key and lock assembly UK mains cable for large cabinet UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant only) Peripheral Interface Board 8 inputs (Large cabinet variant Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop small cabinet (Scandinavia) 1199a/06 Incorporating the following units: 2010-2F1-MB ZP2-UI-SC 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: 2X-F1-FB2-S, 2X-F1-FB2 ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop small cabinet 1199a/07 Incorporating the following units: 2010-2F1-MB 2X-UI-FB2 20 Oct 2014 Main control board User interface control board 139 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2010-2-PS-40 4A Power Supply And as optional modules: ZP2-F1-FB2, ZP2-F1-FB2S 2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB Peripheral Interface Board (Germany) (Large cabinet variant only) 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) ADP-N3E-U IFAM interface card (master) (Large cabinet variant only) ADP-N3S interface card (slave) (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-FB2-TP Translucent door option for large cabinet* 2X-D-FB2-TP-S Translucent door option for small cabinet* 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 1 loop small cabinet 1199a/07 Incorporating the following units: 2010-2F1-MB ZP2-UI-FB2 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: 2X-E1, 2X-E1-S ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board (Germany) (Large cabinet variant 2010-2-PIB only) Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) Peripheral Interface Board 8 inputs (Large cabinet variant 2010-2-PIB-8I only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) ADP-N3E-U IFAM interface card (master) (Large cabinet variant only) ADP-N3S interface card (slave) (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-FB2-TP Translucent door option for large cabinet* ZP2-D-FB2-TP-S Translucent door option for small cabinet* Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 1 loop Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 1 loop small Cabinet 1199a/08 Incorporating the following units: 2010-2F1-MB 2X-UI-E 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: 140 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2X-ZI-20 2X-ZI-40 2X-ZI-24-S 2010-2-NB 2X-LB Loop Board 2010-2-232-KIT 2010-2-PS-C2 2010-2-PS-C2-S 2010-2-PIB-8O only) 2010-2-PIB-8I only) 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT 2X-D-E-TP 2X-D-E-TP-S 2010-FS-EOL KFP-AE1, KFP-AE1-S (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) (24 Zone) (Small cabinet variant only) Network card (Large cabinet variant only) Interface board for external printer UK mains cable for large cabinet UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant Peripheral Interface Board 8 inputs (Large cabinet variant Peripheral Interface Board 8 outputs and 8 inputs (Large with ATS7310 (GSM module) Translucent door option for large cabinet* Translucent door option for small cabinet* Fault Supervision End of Line unit Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 1 loop Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 1 loop small cabinet 1199a/08 Incorporating the following units: 2010-2F1-MB KFP-A-UI-E 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: KFP-A-ZI-20 KFP-A-ZI-40 KFP-A-ZI-24-S 2010-2-NB KFP-A-LB 2010-2-232-KIT 2010-2-PS-C2 2010-2-PS-C2-S 2010-2-PIB-8O only) 2010-2-PIB-8I only) 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT 2010-FS-EOL (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) (24 Zone) (Small cabinet variant only) Network card Loop Board (Large cabinet variant only) Interface board for external printer UK mains cable for large cabinet UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant Peripheral Interface Board 8 inputs (Large cabinet variant Peripheral Interface Board 8 outputs and 8 inputs (Large with ATS7310 (GSM module) Fault Supervision End of Line unit The above fire panels are certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment (not available on KFP-A-F1 and KFP-A-F1-S) 7.9.2 Alarm confirmation input from fire alarm routing equipment (not available on KFP-A-F1 and KFP-A-F1-S) 7.10 Output to fire protection equipment - Type A,B and C (not available on KFP-A-F1 and KFP-A-F1-S) 7.11 Delays to outputs 7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 1. Available with the following language kit options: -01 Dutch (NL) The Netherlands-02 20 Oct 2014 141 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products ZP2-E1, ZP2-E1-S LPCB Ref. No. French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English 2. Scope of the approval does not indicate the operation of the networkfunctionality Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 1 loop Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 1 loop small cabinet 1199a/08 Incorporating the following units: 2010-2F1-MB ZP2-UI-E 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-E-TP Translucent door option for large cabinet* ZP2-D-E-TP-S Translucent door option for small cabinet* The above fire panels are certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment (not available on ZP2F1 and ZP2-F1-S) 7.9.2 Alarm confirmation input from fire alarm routing equipment (not available on ZP2-F1 and ZP2-F1-S) 7.10 Output to fire protection equipment - Type A,B and C (not available on ZP2-F1 and ZP2-F1-S) 7.11 Delays to outputs 7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 142 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products 2X-F1-SCFB-S, 2X-F1SCFB LPCB Ref. No. 1. Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland-13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English 2. Scope of the approval does not indicate the operation of the network functionality *The translucent door does not meet EN54-2 access level 1 requirements. To meet EN54-2 requirements with the door fitted the following is also required: 3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2 part 7.3) 4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to meet requirements of EN54-2 part 7.11) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 1 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 1 loop small cabinet (Scandinavia) 1199a/09 Incorporating the following units: 2010-2F1-MB Main control board 2X-UI-SCFB User interface control board 2010-2-PS-40 4A Power Supply And as optional modules: 2X-ZI-20 2X-ZI-40 2010-2-NB 2X-LB 2010-2-232-KIT 2010-SK 2010-2-PS-C2 2010-2-PS-C2-S 2010-2-PIB-8O 2010-2-PIB-8I 2010-2-PIB-8I8O variant only) 2010-2-DACT 2010-FS-EOL (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) Network card Loop Board (Large cabinet variant only) Interface board for external printer Scandinavian key and lock assembly UK mains cable for large cabinet UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant only) Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet with ATS7310 (GSM module) Fault Supervision End of Line unit The above fire panels are certified with the following options with requirements from EN 54-2: 7.8 7.9.1 Output to fire alarm device(s) Output to fire alarm routing equipment (not available on 2X- F1 and 2X-F1-S) 7.9.2 Alarm confirmation input from fire alarm routing equipment (not available on 2X-F1 and 2X-F1-S) 7.10 Output to fire protection equipment - Type A,B and C (notavailable on 2X-F1 and 2X-F1-S) 7.11 Delays to outputs 7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 20 Oct 2014 143 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 10 KFP-AF1-SCFB, KFP-AF1SCFB-S Test condition Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Available with the following language kit options: -01 Dutch (NL) The Netherlands, -02 French (FR), -03 English (UK) United Kingdom and Ireland, -04 German (DE) -05 Norwegian, -06 Swedish, -07 Danish (DK), 08 English (AU) Australia, -09 Spanish, -10 Italian, -11 Dutch (BE) Belgium, -12 Irish, -13 German (AU) (Austria), -14 Greek, -15 Arabic, -17 English (US) United States of America, -18 Polish, -19 Turkish, -20 Czech Republic, -21 Portuguese, 22 Hungarian, -23 Danish (IC) Iceland, -24 Slovakian, -25 Russian, -27 Lithuanian, -28 Finnish, -29 German (SW) Switzerland, -30 Estonian,-31 Latvian, 32 French (BE) Belgium, -33 French (SW) Switzerland, -34 Italian (SW) Switzerland, -36 French (Int) International, -40 Bulgarian, -41 Belarusian, -43 Ukrainian, -44 Serbian, -45 Romanian (RO), -46 German (Int) International, -48 Croatian, -49 Macedonian, -50 Slovenian, -51 Hebrew, -71 Catalan, -80 Chinese, -99 English (Int) International English 2. Scope of the approval does not indicate the operation of the network functionality *The translucent door does not meet EN54-2 access level 1 requirements. To meet EN54-2 requirements with the door fitted the following is also required: 3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2 part 7.3) 4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to meet requirements of EN54-2 part 7.11) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 1 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop with printer 1199a/09 Incorporating the following units: 2010-2F1-MB KFP-A-UI-SCFB 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: ZP2-F1-SCFB, ZP2-F1SCFB-S KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 1 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 1 loop small cabinet (Scandinavia) 1199a/09 Incorporating the following units: 2010-2F1-MB ZP2-UI-SCFB 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: ZP2-ZI-20 144 (20 Zone) (Large cabinet variant only) 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products 2X-F2, 2X-F2-PRT, 2X-F2S LPCB Ref. No. ZP2-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface - 2 loop Intelligent Analogue Addressable Fire Panel with user interface - 2 loop with printer Intelligent Analogue Addressable Fire Panel with user interface - 2 loop small cabinet 1199a/10 Incorporating the following units: 2010-2F2-MB 2X-UI User 2010-2-PS-40 4A Main control board interface control board Power Supply And as optional modules: KFP-AF2,KFP-AF2-PRT, KFP-AF2-S 2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PRT Door mounted printer module (2X-F2-PRT variant only) Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-TP Translucent door option for large cabinet* (2X-F2 variant only) 2X-D-TP-S Translucent door option for small cabinet* (2X-F2-S variant only) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface - 2 loop Intelligent Analogue Addressable Fire Panel with user interface - 2 loop with printer Intelligent Analogue Addressable Fire Panel with user interface - 2 loop small cabinet 1199a/10 Incorporating the following units: 2010-2F2-MB KFP-A-UI 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: KFP-A-ZI-20 KFP-A-ZI-40 KFP-A-ZI-24-S 2010-2-NB KFP-A-LB 2010-2-232-KIT 2010-2-PS-C2 2010-2-PS-C2-S 2010-2-PRT 2010-2-PIB-8O only) 2010-2-PIB-8I only) 20 Oct 2014 (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) (24 Zone) (Small cabinet variant only) Network card Loop Board (Large cabinet variant only) Interface board for external printer UK mains cable for large cabinet UK mains cable for small cabinet Door mounted printer module (KFP-A-F2-PRT variant only) Peripheral Interface Board 8 outputs (Large cabinet variant Peripheral Interface Board 8 inputs (Large cabinet variant 145 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products ZP2-F2, ZP2-F2-PRT, ZP2-F2-S LPCB Ref. No. 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface - 2 loop Intelligent Analogue Addressable Fire Panel with user interface - 2 loop with printer Intelligent Analogue Addressable Fire Panel with user interface - 2 loop small cabinet 1199a/10 Incorporating the following units: 2010-2F2-MB ZP2-UI 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: 2X-F2-SC, 2X-F2-SC-S ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PRT Door mounted printer module (ZP2-F2-PRT variant only) Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-TP Translucent door option for large cabinet* (ZP2-F2 variant only) ZP2-D-TP-S Translucent door option for small cabinet* (ZP2-F2-S variant only) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls 2 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls 2 loop small cabinet (Scandinavia) 1199a/11 Incorporating the following units: 2010-2F2-MB Main control board 2X-UI-SC User interface control board 2010-2-PS-40 4A Power Supply And as optional modules: KFP-AF2-SC, KFP-AF2SC-S 2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) Peripheral Interface Board 8 inputs (Large cabinet variant 2010-2-PIB-8I only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls 2 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls 2 loop small cabinet (Scandinavia) 1199a/11 Incorporating the following units: 2010-2F2-MB KFP-A-UI-SC 146 Main control board User interface control board 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2010-2-PS-40 4A Power Supply And as optional modules: ZP2-F2-SC, ZP2-F2-SC-S KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) Peripheral Interface Board 8 inputs (Large cabinet variant 2010-2-PIB-8I only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls 2 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls 2 loop small cabinet (Scandinavia) 1199a/11 Incorporating the following units: 2010-2F2-MB ZP2-UI-SC 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: 2X-F2-FB2-PRT, 2X-F2FB2, 2X-F2-FB2-S ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) Peripheral Interface Board 8 inputs (Large cabinet variant 2010-2-PIB-8I only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop with printer Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop small cabinet 1199a/12 Incorporating the following units: 2010-2F2-MB 2X-UI-FB2 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: 2X-ZI-20 2X-ZI-40 2X-ZI-24-S 2010-2-NB 2X-LB 2010-2-232-KIT 2010-2-PS-C2 2010-2-PS-C2-S 20 Oct 2014 (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) (24 Zone) (Small cabinet variant only) Network card Loop Board (Large cabinet variant only) Interface board for external printer UK mains cable for large cabinet UK mains cable for small cabinet 147 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products KFP-A-F2FB2-PRT KFPAF2-FB2-S KFP-AF2-FB2 LPCB Ref. No. 2010-2-PRT Door mounted printer module (2X-F2-FB2-PRT variant only) Peripheral Interface Board (Germany) (Large cabinet variant 2010-2-PIB only) Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) ADP-N3E-U (Large cabinet variant only) ADP-N3S (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-FB2-TP Translucent door option for large cabinet* (2X-F2-FB2 variant only) 2X-D-FB2-TP-S Translucent door option for large cabinet* (2X-F2-FB2-S variant only) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop with printer Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop small cabinet 1199a/12 Incorporating the following units: 2010-2F2-MB KFP-A-UI-FB2 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: ZP2-F2-FB2, ZP2-F2-FB2 PRT, ZP2F2-FB2-S KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PRT Door mounted printer module (KFP-A-F2-FB2-PRT variant only) Peripheral Interface Board (Germany) (Large cabinet variant 2010-2-PIB only) Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) Peripheral Interface Board 8 inputs (Large cabinet variant 2010-2-PIB-8I only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) ADP-N3E-U (Large cabinet variant only) ADP-N3S (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop with printer Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls - 2 loop small cabinet 1199a/12 Incorporating the following units: 2010-2F2-MB ZP2-UI-FB2 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: ZP2-ZI-20 ZP2-ZI-40 ZP2-ZI-24-S 2010-2-NB 148 (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) (24 Zone) (Small cabinet variant only) Network card 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products 2X-F2-SCFB, 2X-F2SCFB-S LPCB Ref. No. ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PRT Door mounted printer module (ZP2-F2-FB2-PRT variant only) Peripheral Interface Board (Germany) (Large cabinet variant 2010-2-PIB only) Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) ADP-N3E-U (Large cabinet variant only) ADP-N3S (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-FB2-TP Translucent door option for large cabinet* (ZP2-F2-FB2 variant only) ZP2-D-FB2-TP-S Translucent door option for large cabinet* (ZP2-F2-FB2-S variant only) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls 2 loop small cabinet (Scandinavia) 1199a/13 Incorporating the following units: 2010-2F2-MB 2X-UI-SCFB 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: KFP-AF2-SCFB-S, KFPAF2-SCFB 2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop small cabinet (Scandinavia) 1199a/13 Incorporating the following units: 2010-2F2-MB KFP-A-UI-SCFB 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: KFP-A-ZI-20 KFP-A-ZI-40 2010-2-NB KFP-A-LB 2010-2-232-KIT 2010-SK 2010-2-PS-C2 2010-2-PS-C2-S 2010-2-PRT only) 2010-2-PIB-8O 20 Oct 2014 (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) Network card Loop Board (Large cabinet variant only) Interface board for external printer Scandinavian key and lock assembly UK mains cable for large cabinet UK mains cable for small cabinet Door mounted printer module (KFP-A-F2-SCFB-PRT variant Peripheral Interface Board 8 outputs (Large cabinet variant 149 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products ZP2-F2-SCFB-S,ZP2-F2SCFB-PRT,ZP2-F2-SCFB LPCB Ref. No. only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop with printer (Scandinavia) Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade controls - 2 loop small cabinet (Scandinavia) 1199a/13 Incorporating the following units: 2010-2F2-MB ZP2-UI-SCFB 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: 2X-E2, 2X-E2-S ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PRT Door mounted printer module (ZP2-F2-SCFB-PRT variant only) 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) Peripheral Interface Board 8 inputs (Large cabinet variant 2010-2-PIB-8I only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 2 loop Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls 2 loop small cabinet 1199a/14 Incorporating the following units: 2010-2F2-MB 2X-UI-E 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: 2X-ZI-20 2X-ZI-40 2X-ZI-24-S 2010-2-NB 2X-LB 2010-2-232-KIT 2010-2-PS-C2 2010-2-PS-C2-S 2010-2-PIB-8O only) 2010-2-PIB-8I only) 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT 2X-D-E-TP 2X-D-E-TP-S 2010-FS-EOL (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) (24 Zone) (Small cabinet variant only) Network card Loop Board (Large cabinet variant only) Interface board for external printer UK mains cable for large cabinet UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant Peripheral Interface Board 8 inputs (Large cabinet variant Peripheral Interface Board 8 outputs and 8 inputs (Large with ATS7310 (GSM module) Translucent door option for large cabinet* Translucent door option for large cabinet* Fault Supervision End of Line unit The above fire panels are certified with the following options with requirements from EN 150 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment (not available on 2XF2, 2X-F2-PRT and 2X-F2-S) 7.9.2 Alarm confirmation input from fire alarm routing equipment (not available on 2X-F2, 2X-F2-PRT and 2X-F2-S) 7.10 Output to fire protection equipment - Type A,B and C (not available on 2X-F2, 2X-F2-PRT and 2X-F2-S) 7.11 Delays to outputs 7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13 . 1.Available with the following language kit options: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 5413. 1. Available with the following language kits:-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland-13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary-23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English2.Scope of the approval does not indicate the operation of the network functionality KFP-AE2, KFP-AE2-S *The translucent door does not meet EN54-2 access level 1 requirements. To meet EN54-2 requirements with the door fitted the following is also required: 3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2 part 7.3) 4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to meet requirements of EN54-2 part 7.11) Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 2 loop Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 2 loop small cabinet 1199a/14 Incorporating the following units: 2010-2F2-MB KFP-A-UI-E 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: KFP-A-ZI-20 KFP-A-ZI-40 KFP-A-ZI-24-S 2010-2-NB 20 Oct 2014 (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) (24 Zone) (Small cabinet variant only) Network card 151 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) Peripheral Interface Board 8 inputs (Large cabinet variant 2010-2-PIB-8I only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit The above fire panels are certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment (not available on KFPAF2, KFP-AF2-PRT and KFP-AF2-S) 7.9.2 Alarm confirmation input from fire alarm routing equipment (not available on KFP-A-F2, KFP-AF2-PRT and KFP-AF2-S) 7.10 Output to fire protection equipment - Type A,B and C (not available on KFP-A-F2, KFP-A-F2-PRT and KFP-A-F2-S) 7.11 Delays to outputs 7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition ZP2-E2, ZP2-E2-S Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 1. Available with the following language kit options: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland-13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French (SW) Switzerland34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English 2. Scope of the approval does not indicate the operation of the network functionality Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 2 loop Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire brigade controls - 2 loop small cabinet 1199a/14 Incorporating the following units: 2010-2F2-MB Main control board ZP2-UI-E User interface control board 2010-2-PS-40 4A Power Supply And as optional modules: ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 152 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-E-TP Translucent door option for large cabinet* ZP2-D-E-TP-S Translucent door option for large cabinet* The above fire panels are certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment (not available on ZP2F2, ZP2-F2-PRT and ZP2-F2-S) 7.9.2 Alarm confirmation input from fire alarm routing equipment (not available on ZP2-F2, ZP2-F2-PRT and ZP2-F2-S) 7.10 Output to fire protection equipment - Type A,B and C (not available on ZP2-F2, ZP2-F2-PRT and ZP2-F2-S) 7.11 Delays to outputs 7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 2X-FR, 2X-FR-S Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 1. Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland-13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French (SW) Switzerland34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English 2. Scope of the approval does not indicate the operation of the network functionality *The translucent door does not meet EN54-2 access level 1 requirements. To meet EN54-2 requirements with the door fitted the following is also required: 3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2 part 7.3) 4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to meet requirements of EN54-2 part 7.11) Intelligent Analogue Addressable Fire Panel Repeater Intelligent Analogue Addressable Fire Panel Repeater small cabinet 1199a/R01 Incorporating the following units: 2010-2FR-MB 2X-UI 20 Oct 2014 Main control board User interface control board 153 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2010-2-PS-40 4A Power Supply And as optional modules: KFP-A-FR, KFP-A-FR-S 2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-TP Translucent door option for large cabinet* 2X-D-TP-S Translucent door option for small cabinet* 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel Repeater Intelligent Analogue Addressable Fire Panel Repeater small cabinet 1199a/R01 Incorporating the following units: 2010-2FR-MB KFP-A-UI 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: ZP2-FR, ZP2-FR-S KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) Peripheral Interface Board 8 inputs (Large cabinet variant 2010-2-PIB-8I only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel Repeater Intelligent Analogue Addressable Fire Panel Repeater small cabinet 1199a/R01 Incorporating the following units: 2010-2FR-MB ZP2-UI 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 154 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products 2X-FR-FB2, 2X-FR-FB2-S LPCB Ref. No. 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-TP Translucent door option for large cabinet* ZP2-D-TP-S Translucent door option for small cabinet* Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small cabinet 1199a/R02 Incorporating the following units: 2010-2FR-MB Main control board 2X-UI-FB2 User interface control board 2010-2-PS-40 4A Power Supply And as optional modules: KFP-A-FR-FB2-S, KFP-AFR-FB2 2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB Peripheral Interface Board (Germany) (Large cabinet variant only) 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) ADP-N3E-U IFAM interface card (master) (Large cabinet variant only) ADP-N3S interface card (slave) (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-FB2-TP Translucent door option for large cabinet* 2X-D-FB2-TP-S Translucent door option for small cabinet* 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small cabinet 1199a/R02 Incorporating the following units: 2010-2FR-MB KFP-A-UI-FB2 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: ZP2-FR-FB2 ZP2-FR-FB2S KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board (Germany) (Large cabinet variant 2010-2-PIB only) Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) ADP-N3E-U IFAM interface card (master) (Large cabinet variant only) ADP-N3S interface card (slave) (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small cabinet 1199a/R02 Incorporating the following units: 2010-2FR-MB ZP2-UI-FB2 20 Oct 2014 Main control board User interface control board 155 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2010-2-PS-40 4A Power Supply And as optional modules: 2X-FR-SC ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) ZP2-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board (Germany) (Large cabinet variant 2010-2-PIB only) Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) Peripheral Interface Board 8 inputs (Large cabinet variant 2010-2-PIB-8I only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) ADP-N3E-U IFAM interface card (master) (Large cabinet variant only) ADP-N3S interface card (slave) (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit ZP2-D-FB2-TP Translucent door option for large cabinet* ZP2-D-FB2-TP-S Translucent door option for small cabinet* Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls (Scandinavia) Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small cabinet (Scandinavia) 1199a/R03 Incorporating the following units: 2010-2FR-MB Main control board 2X-UI-SC User interface control board 2010-2-PS-40 4A Power Supply And as optional modules: KFP-A-FR-SC, KFP-A-FRSC-S 2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2X-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB Peripheral Interface Board (Germany) 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls (Scandinavia) Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small cabinet (Scandinavia) 1199a/R03 Incorporating the following units: 2010-2FR-MB KFP-A-UI-SC 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: KFP-A-ZI-20 KFP-A-ZI-40 2010-2-NB KFP-A-LB 2010-2-232-KIT 156 (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) Network card Loop Board (Large cabinet variant only) Interface board for external printer 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products ZP2-FR-SC, ZP2-FR-SC-S LPCB Ref. No. 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls (Scandinavia) Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small cabinet (Scandinavia) 1199a/R03 Incorporating the following units: 2010-2FR-MB ZP2-UI-SC 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: 2X-ER, 2X-ER-S ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Inte rface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade controls Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade controls small cabinet 1199a/R04 Incorporating the following units: 2010-2FR-MB 2X-UI-E 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: 2X-ZI-20 2X-ZI-40 2X-ZI-24-S 2010-2-NB 2X-LB 2010-2-232-KIT 2010-2-PS-C2 2010-2-PS-C2-S 2010-2-PIB-8O 2010-2-PIB-8I 2010-2-PIB-8I8O variant only) 2010-2-DACT 2X-D-E-TP 2X-D-E-TP-S 2010-FS-EOL (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) (24 Zone) (Small cabinet variant only) Network card Loop Board (Large cabinet variant only) Interface board for external printer UK mains cable for large cabinet UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant only) Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet with ATS7310 (GSM module) Translucent door option for large cabinet* Translucent door option for small cabinet* Fault Supervision End of Line unit The above ancillary repeater units are certified with the following options with requirements from EN 54-2: 7.13 20 Oct 2014 Alarm counter 157 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 8.4 8.9 9.5 S variants only) 10 Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points (available on 2X-ER and 2X-ERTest condition (available on 2X-ER and 2X-ER-S variants only) *Important: the translucent door does not meet EN54-2 access level 1 requirements. To meet EN54-2 requirements with the door fitted the following is also required: 1) A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2 part 7.3) KFP-A-ER KFP-A-ER-S 2) An MCP fitted beside the panel to allow overriding of delays (to meet requirements of EN54-2 part 7.11) Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade controls Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade controls small cabinet 1199a/R04 Incorporating the following units: 2010-2FR-MB KFP-A-UI-E 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: KFP-A-ZI-20 (20 Zone) (Large cabinet variant only) KFP-A-ZI-40 (40 Zone) (Large cabinet variant only) KFP-A-ZI-24-S (24 Zone) (Small cabinet variant only) 2010-2-NB Network card KFP-A-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) Peripheral Interface Board 8 inputs (Large cabinet variant 2010-2-PIB-8I only) Peripheral Interface Board 8 outputs and 8 inputs (Large 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Above ancillary repeater units are certified with the following options with requirements from EN 54-2: ZP2-ER, ZP2-ER-S 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points (available on 2X-ER and 2X-ER-S variants only) 10 Test condition (available on 2X-ER and 2X-ER-S variants only Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade controls Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade controls small cabinet 1199a/R04 Incorporating the following units: 2010-2FR-MB ZP2-UI-E 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: ZP2-ZI-20 ZP2-ZI-40 ZP2-ZI-24-S 2010-2-NB ZP2-LB 158 (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) (24 Zone) (Small cabinet variant only) Network card Loop Board (Large cabinet variant only) 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2010-2-232-KIT 2010-2-PS-C2 2010-2-PS-C2-S 2010-2-PIB-8O only) 2010-2-PIB-8I 2010-2-PIB-8I8O cabinet variant only) 2010-2-DACT 2010-FS-EOL ZP2-D-E-TP ZP2-D-E-TP-S Interface board for external printer UK mains cable for large cabinet UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large with ATS7310 (GSM module) Fault Supervision End of Line unit Translucent door option for large cabinet* Translucent door option for small cabinet Certified with the following options with requirements from EN 54-2: 2X-FR-SCFB, 2X-FRSCFB-S 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points (available on 2X-ER and 2XER-S variants only) 10 Test condition (available on 2X-ER and 2X-ER-S variants only) Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls (Scandinavia) Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls small cabinet (Scandinavia) 1199a/R05 Incorporating the following units: 2010-2FR-MB 2X-UI-SCFB 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: KFP-A-FR-SCFB, KFP-AFR-SCFB-S 2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls (Scandinavia) Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls small cabinet (Scandinavia) 1199a/R05 Incorporating the following units: 2010-2FR-MB KFP-A-UI-SCFB 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: KFP-A-ZI-20 KFP-A-ZI-40 2010-2-NB KFP-A-LB 2010-2-232-KIT 2010-SK 2010-2-PS-C2 2010-2-PS-C2-S 2010-2-PIB-8O only) 2010-2-PIB-8I 2010-2-PIB-8I8O 20 Oct 2014 (20 Zone) (Large cabinet variant only) (40 Zone) (Large cabinet variant only) Network card Loop Board (Large cabinet variant only) Interface board for external printer Scandinavian key and lock assembly UK mains cable for large cabinet UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant Peripheral Interface Board 8 inputs (Large cabinet variant only) Peripheral Interface Board 8 outputs and 8 inputs (Large 159 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products ZP2-FR-SCFB, ZP2-FRSCFB-S LPCB Ref. No. cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls (Scandinavia) Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls small cabinet (Scandinavia) 1199a/R05 Incorporating the following units: 2010-2FR-MB ZP2-UI-SCFB 2010-2-PS-40 4A Main control board User interface control board Power Supply And as optional modules: 1X-F2 1X-F2 1X-F2-SC 160 ZP2-ZI-20 (20 Zone) (Large cabinet variant only) ZP2-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card ZP2-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-SK Scandinavian key and lock assembly 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet Peripheral Interface Board 8 outputs (Large cabinet variant 2010-2-PIB-8O only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2010-FS-EOL Fault Supervision End of Line unit Conventional two zone control and indicating equipment Conventional two zone control and indicating equipment with Scandinavian key switch I ncorporating the following units: 2010-2F1- MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply And as optional modules: 2X-ZI-20 (20 Zone) (Large cabinet variant only) 2X-ZI-40 (40 Zone) (Large cabinet variant only) 2010-2-NB Network card 2X-LB Loop Board (Large cabinet variant only) 2010-2-232-KIT Interface board for external printer 2010-2-PS-C2 UK mains cable for large cabinet 2010-2-PS-C2-S UK mains cable for small cabinet 2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet variant only) 2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant only) 2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet variant only) 2010-2-DACT with ATS7310 (GSM module) 2X-D-TP Translucent door option for large cabinet* 2X-D-TP-S Translucent door option for small cabinet* 2010-FS-EOL Fault Supervision End of Line unit 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. International English 3) Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland- 1199b/01 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products KFP-CF2 KFP-CF2-SC SG-2000 SG-2000SC 1X-F4 SC 1X-F4-NL 1X-F4- 20 Oct 2014 LPCB Ref. No. 13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int Conventional two zone control and indicating equipment Conventional two zone control and indicating equipment with Scandinavian key switch Conventional two zone control and indicating equipment Conventional two zone control and indicating equipment with Scandinavian key switch Conventional two zone control and indicating equipment Conventional two zone control and indicating equipment with Scandinavian key switch Incorporating the following units: 1X-F2-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-20 2A Power Supply 2010-SK Scandinavian Key Lock and Key (Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.11 Delays to outputs 8.4 Total loss of the power supply 10 Test condition 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania -46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia50 Slovenian 1X-F4 1X-F4-NL 1X-F4-SC Incorporating the following units: 1X-F4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 1199b/01 1199b/01 1199b/02 161 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2010-1-NB Optional Network board 2010-PS-20 2A Power Supply 2010-1-AC Alarm Counter (Applicable to NL variant) 2010-SK Scandinavian Key Lock and Key (Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 10 Test condition Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: KFP-CF4 KFP-CF4-NL KFP-CF4-SC 162 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English KFP-CF4 KFP-CF4-NL KFP-CF4-SC Conventional four zone control and indicating equipment Incorporating the following units: KFP-CF4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-20 2A Power Supply 2010-1-AC Alarm Counter (Applicable to NL variant) 2010-SK Scandinavian Key Lock and Key (Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 10 Test condition 1199b/02 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products SG-4000 SG-4000SC 20 Oct 2014 LPCB Ref. No. Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English SG-4000 SG-4000SC Conventional eight zone control and indicating equipment Conventional eight zone control and indicating equipment Conventional eight zone control and indicating equipment Incorporating the following units: 1X-F4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-20 2A Power Supply 2010-SK Scandinavian Key Lock and Key (Applicable to SC variant Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 8.4 Total loss of the power supply 10 Test condition 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian 1199b/02 163 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products ZP1-F4 ZP1-F4-NL ZP1F4-SC LPCB Ref. No. Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English ZP1-F4 ZP1-F4-NL ZP1-F4-SC Conventional four zone control and indicating equipment 1199b/02 Incorporating the following units: 1X-F4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-20 2A Power Supply 2010-1-AC Alarm Counter (Applicable to NL variant) 2010-SK Scandinavian Key Lock and Key (Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 10 Test condition Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English 164 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products ZP1-F4 ZP1-F4-NL ZP1F4-SC 1X-F8 1X-F8-NL 1X-F8-SC ZP1-F4 ZP1-F4-NL ZP1-F4-SC Conventional four zone control and indicating equipment Incorporating the following units: 1X-F4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-20 2A Power Supply 2010-1-AC Alarm Counter (Applicable to NL variant) 2010-SK Scandinavian Key Lock and Key (Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 10 Test condition Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 1X-F8 1X-F8-NL 1X-F8-SC Conventional eight zone control and indicating equipment Incorporating the following units: LPCB Ref. No. 1199b/02 1199b/03 1X-F8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-40 4A Power Supply 2010-1-AC Alarm Counter ( Applicable to NL variant) 2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter ( Applicable to NL variant only) 8.4 Total loss of the power supply 10 Test condition Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment 1X-F8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-40 4A Power Supply 2010-1-AC Alarm Counter ( Applicable to NL variant) 2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter ( Applicable to NL variant only) 8.4 Total loss of the power supply 10 Test condition Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 20 Oct 2014 165 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products KFP-CF8 KFP-CF8-NL KFP-CF8-SC SG-8000 SG-8000SC 166 LPCB Ref. No. 7.11 Delays to outputs - Applicable to fire alarm routing equipment KFP-CF8 KFP-CF8-NL KFP-CF8-SC Conventional eight zone control and indicating equipment Incorporating the following units: KFP-CF8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-40 4A Power Supply 2010-1-AC Alarm Counter ( Applicable to NL variant) 2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter ( Applicable to NL variant only) 8.4 Total loss of the power supply 10 Test condition Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania -46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English SG-8000 SG-8000SC Conventional eight zone control and indicating equipment Conventional eight zone control and indicating equipment Conventional eight zone control and indicating equipment Incorporating the following units: 1X-F8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-40 4A Power Supply 2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 1199b/03 1199b/03 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 8.4 Total loss of the power supply 10 Test condition 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) ZP1-F8 ZP1-F8-NL ZP1F8-SC German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary-23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English ZP1-F8 ZP1-F8-NL ZP1-F8-SC Conventional four zone control and indicating equipment 1199b/03 Incorporating the following units: 1X-F8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-40 4A Power Supply 2010-1-AC Alarm Counter ( Applicable to NL variant) 2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant) Incorporating the following units: 1X-F8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-40 4A Power Supply 2010-1-AC Alarm Counter ( Applicable to NL variant) 2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment -Type A 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 20 Oct 2014 167 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products 1X-E4 1X-E4-NL KFP-CE4 KFP-CE4-N 168 LPCB Ref. No. German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania -46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) 1X-E4 1X-E4-NL Conventional four zone control and indicating equipment Incorporating the following units: 1X-E4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-40 4A Power Supply 2010-1-AC Alarm Counter (Applicable to NL variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 10 Test condition Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania -46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English KFP-CE4 KFP-CE4-NL Conventional four zone control and indicating equipment Incorporating the following units: 1199b/04 1199b/04 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products ZP1-E4 ZP1-E4-NL 20 Oct 2014 LPCB Ref. No. KFP-CE4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-PS-40 4A Power Supply 2010-1-AC Alarm Counter (Applicable to NL variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 10 Test condition Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs - Applicable to fire alarm routing equipment only 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania -46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew ZP1-E4 ZP1-E4-NL Conventional four zone control and indicating equipment Incorporating the following units: 1X-E4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-40 4A Power Supply 2010-1-AC Alarm Counter (Applicable to NL variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 10 Test condition Also certified with the following options with requirements from EN 54-2 when configured in the NEN operating mode: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs - Applicable to fire alarm routing equipment 1199b/04 169 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. only 7.13 Alarm counter (Applicable to NL variant only) 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: -01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE) Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania -46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99 English (Int) International English ZP3 1, 2 and 4 loop analogue addressable control and indicating equipment 1, 2 and 4 loop analogue addressable control and indicating equipment Incorporating as modular units: ZP3-MB2-4L 4 Loop Main board ZP3-MB2-2L 2 Loop Main board ZP3-MB2-1L 1 Loop Main board ZP3-CPU1 CPU board ZP3-DB1 Display board ZP3-ZB50 50 Zone LED board ZP3-CB1 Commissioning key switch board ZP3-PR1 Printer Kit ZP3AB-SCB-D Control bus driver ZP3AB-RL8 Programmable relay output board, 8 way ZP3-AB-MA8 Programmable monitored output board, 8 way ZP3AB-OP24 Programmable transistor output board, 24 way ZP3AB-MIP8 Programmable input board, 8 way ZP3-Xl 230Vac Power supply unit Approved with the following options from BS EN54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 7.12 Co-incidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.4 Total loss of power 8.9 Output to fault routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardised input/output interface 170 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT UTC Fire & Security (Africa) trading as Ziton Ziton House, 555 Voortrekker Road, Maitland 7405, Cape Town, South Africa Tel: +27 21 5066000 • Fax: +27 21 5066100 Website: www.utcfireandsecurity.com UK Sales Enquiries: Tel: +44 (0)1908 281981 • Fax: +44 (0)1908 282554 Certificate No: 092h to BS EN 54-2: 1998 and BS EN 54-4: 1998 N.B. This certificate is to a withdrawn standard. Control and indicating equipment conforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because control and indicating equipment meeting the withdrawn standard is still requested by some regulators outside of the EU. Certificated Products ZP3 1, 2 and 4 loop analogue addressable control and indicating equipment Incorporating as modular units: LPCB Ref. No. 092h/01 ZP3-MB2-4L 4 Loop Main board ZP3-MB2-2L 2 Loop Main board ZP3-MB2-1L 1 Loop Main board ZP3-CPU1 CPU board ZP3-DB1 Display board ZP3-ZB50 50 Zone LED board ZP3-CB1 Commissioning key switch board ZP3-PR1 Printer Kit ZP3AB-SCB-D Control bus drive ZP3AB-RL8 Programmable relay output board, 8 way ZP3-AB-MA8 Programmable monitored output board, 8 way ZP3AB-OP24 Programmable transistor output board, 24 way ZP3AB-MIP8 Programmable input board, 8 way ZP3-xL 230V ac Power supply unit Approved with the following options from EN54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 7.12 Co-incidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault routing equipment 9.5 Disablement of addressable points 10.0 Test condition 11.0 Standardised input/output interface UTC Fire & Security (Pty) LTD Trading as Ziton Ziton House, 555 Voortrekker Road, Maitland 7405, South Africa Tel: +27 21 5066000 • Fax: +27 21 5066100 Website: www.ziton.com Certificate No: 092h to BS EN 54 - 2: 1998 and BS EN 54- 4: 1998 N.B. This certificate is to a withdrawn standard. Control and indicating equipment conforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because controland indicating equipment meeting the withdrawn standard is still requested by some regulators outside of the EU. Certificated Products ZP3 (Traditional Chinese Language Variant) 1, 2 and 4 loop analogue addressable control and indicating equipment LPCB Ref. No. 092h/01 Incorporating as modular units: 20 Oct 2014 171 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. ZP3-MB2-4L 4 Loop Main board ZP3-MB2-2L 2 Loop Main board ZP3-MB2-1L 1 Loop Main board ZP3-CPU1 CPU board ZP3-DB1 Display board ZP3-ZB50 50 Zone LED board ZP3-CB1 Commissioning key switch board ZP3-PR1 Printer Kit ZP3AB-SCB-D Control bus driver ZP3AB-RL8 Programmable relay output board, 8 way ZP3-AB-MA8 Programmable monitored output board, 8 way ZP3AB-OP24 Programmable transistor output board, 24 way ZP3AB-MIP8 Programmable input board, 8 way ZP3-Xl 230Vac Power supply unit Approved with the following options from BS EN54 Part 2: 7.8 7.9 7.10 7.11 7.12 7.13 8.3 8.4 8.9 9.5 10 11 Output to fire alarm devices Output to fire alarm routing equipment Output to fire protection equipment Delays to outputs Co-incidence detection Alarm counter Fault signals from points Total loss of power Output to fault routing equipment Disablement of addressable points Test condition Standardised input/output interface UTC Fire & Security BV Kelvinstraat 7, NL-6003DH, Weert, The Netherlands Tel: + 31 495 58 30 00 • Fax: + 31 495 55 00 42 E-mail: Daragh.O'[email protected] • Website: www.utcfireandsecurity.com Certificate No: 1199c to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 1199c to EN 54-2: 1997 + A1:2006 EN54-4:1997 + A1:2002+ A2:2002 Certificated Products SG2000 LPCB Ref. No. 092v/01 Conventional two zone control and indicating equipment Incorporating the following units: 1X-F2-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-20 2A Power Supply 2010-SK Scandinavian Key Lock and Key (Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.11 Delays to outputs 8.4 Total loss of the power supply 10 Test condition 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 Romanian, 71 Catalan, 99 - English (International) 172 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products SG2000SC LPCB Ref. No. Conventional two zone control and indicating equipment with Scandinavian key switch 092v/01 Incorporating the following units: 1X-F2-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-20 2A Power Supply 2010-SK Scandinavian Key Lock and Key (Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.11 Delays to outputs 8.4 Total loss of the power supply 10 Test condition SG4000 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 - Dutch, 02 -French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 - Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 - Arabic, 18 - Polish, 19 Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27Lithuanian, 28 - Finish, 30 - Estonian, 31 - Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 - Catalan, 99 - English (International) Conventional four zone control and indicating equipment 092v/02 Incorporating the following units: 1X-F4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-20 2A Power Supply 2010-SK Scandinavian Key Lock and Key (Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 8.4 Total loss of the power supply 10 Test condition SG4000SC 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 Romanian, 71 Catalan, 99 - English (International) Conventional four zone control and indicating equipment with Scandinavian key switch 092v/02 Incorporating the following units: 1X-F4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-20 2A Power Supply 2010-SK Scandinavian Key Lock and Key (Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 20 Oct 2014 173 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 8.4 Total loss of the power supply 10 Test condition SG8000 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 Romanian, 71 Catalan, 99 - English (International) Conventional eight zone control and indicating equipment 092v/03 Incorporating the following units: 1X-F8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-40 4A Power Supply 2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 8.4 Total loss of the power supply 10 Test condition SG8000SC 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 Romanian, 71 Catalan, 99 - English (International) Conventional eight zone control and indicating equipment with Scandinavian key switch 092v/03 Incorporating the following units: 1X-F8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-1-NB Optional Network board 2010-PS-40 4A Power Supply 2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 8.4 Total loss of the power supply 10 Test condition 2X-F1 174 1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits: 01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 Romanian, 71 Catalan, 99 - English (International) 1 Loop intelligent analogue addressable control and indicating equipment 092v/05 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board 2-Loop Node Card Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. 2X-F1-FB This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 1 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output 092v/05 Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-232-IB 2010-2-LB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Interface Board for External Printer Loop expansion board 20 zone LED indication board 40 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. 20 Oct 2014 This product approval does not constitute compliance with the fire detection 175 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2X-F1-SC 092v/05 1 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2X-F2 2 Loop intelligent analogue addressable control and indicating equipment 092v/06 Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 176 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. 2. 3. 2X-F2-FB This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available in the following language variants: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2 Loop intelligent analogue addressable control and indicating equipment 092v/06 Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. 2. 3. 2X-F2-SC This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available in the following language variants: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch 092v/06 Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 20 Oct 2014 Network board Loop expansion board 177 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2X-F1-S 092v/07 1 Loop intelligent analogue addressable fire control panel in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. 2. 3. 2X-F1-FB-S 178 This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 1 Loop intelligent analogue addressable fire control panel with fire alarm routing 092v/08 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. equipment output in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. 2. 3. 2X-F1-SC-S This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key in small cabinet 092v/09 Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Scandinavian key and lock assembly Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 20 Oct 2014 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points 179 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 10 Test condition Notes: 1. 2. 3. 2X-F2-S This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/10 2 Loop intelligent analogue addressable fire control panel in small cabinet Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. 2. 3. 2X-F2-FB-S This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet 092v/11 Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 180 Output to fire alarm device(s) Output to fire alarm routing equipment 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2X-F2-SC-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key 092v/12 Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply 2010-SK Scandinavian key and lock assembly and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2X-FR Addressable Fire Panel Repeater 092v/R01 Incorporating the following options with requirements from EN 54-2: 7.13 20 Oct 2014 Alarm counter 181 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products 2X-FR-FB LPCB Ref. No. 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Output to Fire Routing Equipment 092v/R02 Incorporating the following options with requirements from EN 54-2: 2X-FR-SC 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Scandinavian Key 092v/R03 Incorporating the following options with requirements from EN 54-2: 2X-FR-S 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater in small cabinet 092v/R04 Incorporating the following options with requirements from EN 54-2: 2X-FR-SC-S 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian key in small cabinet 092v/R05 Incorporating the following options with requirements from EN 54-2: 2X-FR-FB-S 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire alarm routing equipment output in small cabinet 092v/R06 Incorporating the following options with requirements from EN 54-2: 7.13 8.4 8.9 9.5 10 Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition ZPU (Traditional Chinese Language Variant) 1, 2 and 4 loop analogue equipment Incorporating as modular units: ZP3-MB2-4L ZP3-MB2-2L ZP3-MB2-1L ZP3-CPU1 ZP3-DB1 ZP3-ZB50 ZP3-CB1 ZP3-PR1 ZP3AB-SCB-D ZP3AB-RL8 ZP3-AB-MA8 ZP3AB-OP24 ZP3AB-MIP8 ZP3-Xl 182 addressable control and indicating 4 Loop Main board 2 Loop Main board 1 Loop Main board CPU board Display board 50 Zone LED board Commissioning key switch board Printer Kit Control bus driver Programmable relay output board, 8 way Programmable monitored output board, 8 way Programmable transistor output board, 24 way Programmable input board, 8 way 230Vac Power supply unit 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Approved with the following options from BS EN54 Part 2: 7.8 7.9 7.10 7.11 7.12 7.13 8.3 8.4 8.9 9.5 10 11 Output to fire alarm devices Output to fire alarm routing equipment Output to fire protection equipment Delays to outputs Co-incidence detection Alarm counter Fault signals from points Total loss of power Output to fault routing equipment Disablement of addressable points Test condition Standardised input/output interface Certificate No: 1199c(cl-1) to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products KFP-AF1 1 Loop intelligent analogue addressable control and indicating equipment LPCB Ref. No. 092v/05 Incorporating the following units: 2010-2-F1-MB Main control board KFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board 2-Loop Node Card Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. 2. 3. KFP-AF1-FB This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 1 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output 092v/05 Incorporating the following units: 2010-2-F1-MB Main control board KFP-A-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-232-IB 20 Oct 2014 Network board Interface Board for External Printer 183 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2010-2-LB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Loop expansion board 20 zone LED indication board 40 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) KFP-AF1-SC 1 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch 092v/05 Incorporating the following units: 2010-2-F1-MB Main control board KFP-A-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 184 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) KFP-AF2 2 Loop intelligent analogue addressable control and indicating equipment 092v/06 Incorporating the following units: 2010-2-F2-MB Main control board KFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. 2. 3. KFP-AF2-FB This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available in the following language variants: 01 – Dutch, 02 – French, 03 – English (UK), 04 – German, 05 – Norwegian, 06 – Swedish, 07 – Danish, 09 – Spanish, 10 – Italian,11 – Belgian, Dutch, 15 – Arabic, 18 – Polish, 19 – Turkish, 20 – Czech, 21 – Portuguese, 22 – Hungarian, 24 – Slovakian, 25 – Russian, 27- Lithuanian, 28 – Finish, 30 – Estonian, 31 – Latvian, 32 - Belgian French, 36 – French International, 45 – Romanian, 71 – Catalan, 99 - English (International) 2 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output 092v/06 Incorporating the following units: 2010-2-F2-MB Main control board KFP-A-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 20 Oct 2014 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment 185 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 9.5 10 Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 – Dutch, 02 – French, 03 – English (UK), 04 – German, 05 – Norwegian, 06 – Swedish, 07 – Danish, 09 – Spanish, 10 – Italian,11 – Belgian, Dutch, 15 – Arabic, 18 – Polish, 19 – Turkish, 20 – Czech, 21 – Portuguese, 22 – Hungarian, 24 – Slovakian, 25 – Russian, 27- Lithuanian, 28 – Finish, 30 – Estonian, 31 – Latvian, 32 - Belgian French, 36 – French International, 45 – Romanian, 71 – Catalan, 99 - English (International) KFP-AF2-SC 092v/06 2 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch Incorporating the following units: 2010-2-F2-MB Main control board KFP-A-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) KFP-AF1-S 1 Loop intelligent analogue addressable fire control panel in small cabinet 092v/07 Incorporating the following units: 2010-2-F1-MB Main control board KFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 186 Network board Loop expansion board Interface board for external printer 24 zone LED indication board 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2010-2-PS-C2 UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. 2. 3. KFP-AF1-FB-S This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet 092v/08 Incorporating the following units: 2010-2-F1-MB Main control board KFP-A-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. 2. 3. KFP-AF1-SC-S 20 Oct 2014 This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key in small cabinet 092v/09 187 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating the following units: 2010-2-F1-MB Main control board KFP-A-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Scandinavian key and lock assembly Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) KFP-AF2-S 2 Loop intelligent analogue addressable fire control panel in small cabinet 092v/10 Incorporating the following units: 2010-2-F2-MB Main control board KFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. 2. 188 This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 3. KFP-AF2-FB-S Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet 092v/11 Incorporating the following units: 2010-2-F2-MB Main control board KFP-A-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) KFP-AF2-SC-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key 092v/12 Incorporating the following units: 2010-2-F2-MB Main control board KFP-A-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply 2010-SK Scandinavian key and lock assembly and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 20 Oct 2014 Output to fire alarm device(s) Output to fire alarm routing equipment 189 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) KFP-AFR Addressable Fire Panel Repeater 092v/R01 Incorporating the following options with requirements from EN 54-2: KFP-AFR-FB 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Output to Fire Routing Equipment 092v/R02 Incorporating the following options with requirements from EN 54-2: KFP-AFR-SC 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Scandinavian Key 092v/R03 Incorporating the following options with requirements from EN 54-2: KFP-AFR-S 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater in small cabinet 092v/R04 Incorporating the following options with requirements from EN 54-2: KFP-AFR-SC-S 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian key in small cabinet 092v/R05 Incorporating the following options with requirements from EN 54-2: KFP-AFR-FB-S 190 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire alarm routing equipment output in small cabinet 092v/R06 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. Incorporating the following options with requirements from EN 54-2: 7.13 8.4 8.9 9.5 10 Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition ZP3 1, 2 and 4 loop analogue addressable control and indicating equipment Incorporating as modular units: ZP3-MB2-4L ZP3-MB2-2L ZP3-MB2-1L ZP3-CPU1 ZP3-DB1 ZP3-ZB50 ZP3-CB1 ZP3-PR1 ZP3AB-SCB-D ZP3AB-RL8 ZP3-AB-MA8 ZP3AB-OP24 ZP3AB-MIP8 ZP3-Xl 4 Loop Main board 2 Loop Main board 1 Loop Main board CPU board Display board 50 Zone LED board Commissioning key switch board Printer Kit Control bus driver Programmable relay output board, 8 way Programmable monitored output board, 8 way Programmable transistor output board, 24 way Programmable input board, 8 way 230Vac Power supply unit Approved with the following options from BS EN54 Part 2: 7.8 7.9 7.10 7.11 7.12 7.13 8.3 8.4 8.9 9.5 10 11 Output to fire alarm devices Output to fire alarm routing equipment Output to fire protection equipment Delays to outputs Co-incidence detection Alarm counter Fault signals from points Total loss of power Output to fault routing equipment Disablement of addressable points Test condition Standardised input/output interface Incorporating as modular units: ZP3-MB2-4L ZP3-MB2-2L ZP3-MB2-1L ZP3-CPU1 ZP3-DB1 ZP3-ZB50 ZP3-CB1 ZP3-PR1 ZP3AB-SCB-D ZP3AB-RL8 ZP3-AB-MA8 ZP3AB-OP24 ZP3AB-MIP8 ZP3-Xl 4 Loop Main board 2 Loop Main board 1 Loop Main board CPU board Display board 50 Zone LED board Commissioning key switch board Printer Kit Control bus driver Programmable relay output board, 8 way Programmable monitored output board, 8 way Programmable transistor output board, 24 way Programmable input board, 8 way 230Vac Power supply unit Approved with the following options from BS EN54 Part 2: 7.8 7.9 7.10 7.11 7.12 7.13 8.3 8.4 8.9 Output to fire alarm devices Output to fire alarm routing equipment Output to fire protection equipment Delays to outputs Co-incidence detection Alarm counter Fault signals from points Total loss of power Output to fault routing equipment 20 Oct 2014 191 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT 9.5 Disablement of addressable points 10 Test condition 11 Standardised input/output interface Incorporating as modular units: ZP3-MB2-4L ZP3-MB2-2L ZP3-MB2-1L ZP3-CPU1 ZP3-DB1 ZP3-ZB50 ZP3-CB1 ZP3-PR1 ZP3AB-SCB-D ZP3AB-RL8 ZP3-AB-MA8 ZP3AB-OP24 ZP3AB-MIP8 ZP3-Xl 4 Loop Main board 2 Loop Main board 1 Loop Main board CPU board Display board 50 Zone LED board Commissioning key switch board Printer Kit Control bus driver Programmable relay output board, 8 way Programmable monitored output board, 8 way Programmable transistor output board, 24 way Programmable input board, 8 way 230Vac Power supply unit Approved with the following options from BS EN54 Part 2: 7.8 7.9 7.10 7.11 7.12 7.13 8.3 8.4 8.9 9.5 10 11 Output to fire alarm devices Output to fire alarm routing equipment Output to fire protection equipment Delays to outputs Co-incidence detection Alarm counter Fault signals from points Total loss of power Output to fault routing equipment Disablement of addressable points Test condition Standardised input/output interface Certificate No: 092v-(cl-2) to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006 Ziton - ZP2 Certificated Products ZP2-F1 1 Loop intelligent analogue addressable control and indicating equipment LPCB Ref. No. 092v/05 Incorporating the following units: 2010-2-F1-MB Main control board ZP-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board 2-Loop Node Card Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 192 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F1-FB 1 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output 092v/05 Incorporating the following units: 2010-2-F1-MB Main control board ZP2-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-232-IB 2010-2-LB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Interface Board for External Printer Loop expansion board 20 zone LED indication board 40 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F1-SC 1 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch 092v/05 Incorporating the following units: 2010-2-F1-MB Main control board ZP2-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 20 Oct 2014 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable 193 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2010-SK Scandinavian key and lock assembly Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F2 092v/06 2 Loop intelligent analogue addressable control and indicating equipment Incorporating the following units: 2010-2-F2-MB Main control board ZP-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available in the following language variants: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F2-FB 2 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output 092v/06 Incorporating the following units: 194 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2010-2-F2-MB ZP2-UI-FB 2010-2-PS-40 Main control board User interface control board with fire routing controls 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F2-SC 2 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch 092v/06 Incorporating the following units: 2010-2-F2-MB Main control board ZP2-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 20 Oct 2014 195 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F1-S 092v/07 1 Loop intelligent analogue addressable fire control panel in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board ZP-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB Network board 2010-2-LB Loop expansion board 2010-2-232-IB Interface board for external printer 2X-ZI-24 24 zone LED indication board 2010-2-PS-C2 UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F1-FB-S 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet 092v/08 Incorporating the following units: 2010-2-F1-MB Main control board ZP2-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 196 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 7.11 7.12 7.13 8.4 8.9 9.5 10 Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F1-SC-S 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key in small cabinet 092v/09 Incorporating the following units: 2010-2-F1-MB Main control board ZP2-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Scandinavian key and lock assembly Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F2-S 2 Loop intelligent analogue addressable fire control panel in small cabinet 092v/10 Incorporating the following units: 2010-2-F2-MB Main control board ZP-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 20 Oct 2014 197 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F2-FB-S 092v/11 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet Incorporating the following units: 2010-2-F2-MB Main control board ZP2-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 198 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products ZP2-F2-SC-S LPCB Ref. No. 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key 092v/12 Incorporating the following units: 2010-2-F2-MB Main control board ZP2-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply 2010-SK Scandinavian key and lock assembly and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-FR Addressable Fire Panel Repeater 092v/R01 Incorporating the following options with requirements from EN 54-2: ZP2-FR-FB 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Output to Fire Routing Equipment 092v/R02 Incorporating the following options with requirements from EN 54-2: ZP2-FR-SC 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Scandinavian Key 092v/R03 Incorporating the following options with requirements from EN 54-2: 7.13 8.4 8.9 9.5 10 20 Oct 2014 Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition 199 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products ZP2-FR-S Addressable Fire Panel Repeater in small cabinet LPCB Ref. No. 092v/R04 Incorporating the following options with requirements from EN 54-2: ZP2-FR-SC-S 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian key in small cabinet 092v/R05 Incorporating the following options with requirements from EN 54-2: ZP2-FR-FB-S 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire alarm routing equipment output in small cabinet 092v/R06 Incorporating the following options with requirements from EN 54-2: 7.13 8.4 8.9 9.5 10 Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition UTC Fire & Security Inc. Trading as Edwards Systems Technology 129 North Main Street, Pittsfield, Maine 04967, USA Tel: 941 739-42228 Website: www.fs.utc.com Certificate No: 262z-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006. Certificate No: 262ab to EN 54-2:1997+A1:2006 , EN 54-4::1997+A1:2002+A2:2006 and EN 54-16:2008 Certificated Products EST3 Incorporating as modular units: LPCB Ref. No. 262ab/01 Annunciators EST3 24 LED Annunciators 3-24Y 3-24Y Annunciator Bill of Materials 3-24Y-E 3-24Y Annunciator Bill of Materials 3-24R 3-24R Annunciator Bill of Materials 3-24R-E 3-24R Annunciator Bill of Materials 3-24G 3-24G Annunciator Bill of Materials 3-24G-E 3-24G Annunciator Bill of Materials 3-12RY 3-12RY Annunciator Bill of Materials 3-12RY-E 3-12RY Annunciator Bill of Materials EST3 18 LED Annunciators 3-6/3S1G2Y 3-6/3S1G2Y Annunciator Bill of Materials 3-6/3S1G2Y-E 3-6/3S1G2Y Annunciator Bill of Materials 3-6/3S1GYR 3-6/3S1GYR Annunciator Bill of Materials 3-6/3S1GYR-E 3-6/3S1GYR Annunciator Bill of Materials 3-6/3S2RY 3-6/3S2RY Annunciator Bill of Materials 3-6/3S2RY-E 3-6/3S2RY Annunciator Bill of Materials 130322-03 3-6/3S2RY - Red-yellow-red, 6 triads - PCB TH level BOM EST3 Control-Display Switch/LEDs 3-12SY 3-12SY 12 Switch-Yellow Bill of Materials 3-12SY-E 3-12SY 12 Switch-Yellow Bill of Materials 200 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 3-12SR 3-12SR-E 3-12SG 3-12SG-E 3-12/S1GY 3-12/S1GY-E 3-12/S1RY 3-12/S1RY-E 3-12/S2Y 3-12/S2Y-E 3-12/S2R 3-12/S2R-E 3-12SR 12 Switch-Red Bill of Materials 3-12SR 12 Switch-Red Bill of Materials 3-12SG 12 Switch-Green Bill of Materials 3-12SG 12 Switch-Green Bill of Materials 3-12/S1GY 12 Switch-Green/Yellow 3-12/S1GY 12 Switch-Green/Yellow 3-12/S1RY 12 Switch-Red/Yellow Bill of Materials 3-12/S1RY 12 Switch-Red/Yellow Bill of Materials 3-12/S2Y - 12 Switches - 24 Yellow Bill of Materials 3-12/S2Y - 12 Switches - 24 Yellow Bill of Materials 3-12/S2R - 12 Switches - 24 Red Bill of Materials 3-12/S2R - 12 Switches - 24 Red Bill of Materials Loop Controller Modules 3-SSDC1-E Signature (Single), driver controller module 3-SDDC1-E Signature (Dual), driver controller module 3-AADC1-E System Sensor driver control module 3-SDC1-E Signature, driver controller module 3-EAC-E Edwards Analog Driver Card 3-EASC-E Edwards (Single) Analogue driver controller module 3-EADC-E Edwards (Dual) Analogue driver controller module Power Supplies 3-PPS/M-230-E 3-BPS/M-230-E 3-BBC/M-230-E 3-PSMON-E 3-BPMON-E 3-BBCMON-E 3-CPU3 3-CPU3-E 3-LDSM 3-LDSM-E 3-IDC 8/4 3-IDC 8/4-E 3-LCD 3-LCD-E 3-LRMF 3-RS485A 3-RS485A-E 3-RS485B 3-RS485B-E 3-RS232 3-RS232-E EFM-2 EFM-10 Primary Power Supply 230V Booster Power Supply 230V Booster, Battery Charger Power Supply 230V Primary Power Supply Monitor Booster Power Supply Monitor Booster, Battery Charger Monitor Central Processor Unit Central Processor Unit Annunciator strip support module Annunciator strip support module Initiating Device Circuits/NACS Initiating Device Circuits/NACS EST3 Main Display LCD, user interface EST3 Main Display LCD, user interface Local Rail Module Filler Data Communication, Class A Data Communication, Class A Data Communication, Class B Data Communication, Class B Serial Communications Card (Printer, etc) Serial Communications Card (Printer, etc) Data Communications Filter - 2 Circuits Data Communications Filter - 10 Circuits Cabinets & Door Assemblies 3-CAB7B-E Cabinet Back Box 3-CAB7B-E 3-CAB14B-E Cabinet Back Box 3-CAB14B-E 3-CAB21B-E Cabinet Back Box 3-CAB21B-E Lobby Cabinet Assemblies 3-CAB7D(R)-E 3-CAB7D-E Door Assembly - (R) indicates red 3-CAB14D(R)-E 3-CAB14D-E Door Assembly - (R) indicates red 3-CAB21D(R)-E 3-CAB21D-E Door Assembly - (R) indicates red Battery Cabinets 3-RCC7R-E 3-RCC14R-E 3-RCC21R-E 3-BTSEN-E BC-1 3-TAMP 3-TAMPRCC EST3 - CAB 7 Module Chassis - Remote Closet Cabinet EST3 - CAB 14 Module Chassis - Remote Closet Cabinet EST3 - CAB 21 Module Chassis - Remote Closet Cabinet Remote battery cabinet interlace, temperature sensing Battery Cabinet Cabinet Tamper Switch for 3-CAB7/14/21 Tamper Switch for 3-RCC Cabinet Audio & Telephone Common Controls - Chassis Assemblies 3-CHAS7 EST3 - CHASSIS 7 Module - Chassis Assy for 7 LRMs 3-CHAS7-E EST3 - CHASSIS 7 Module - Chassis Assy for 7 LRMs 3-CHASS4 EST3 -CHASSIS 4 Mod - Chassis Assy for REMIC & 4 LRMs 3-CHASS4-E EST3 -CHASSIS 4 Mod - Chassis Assy for REMIC & 4 LRMs 3-ASU-E Audio Source Unit with a 3-Chassis - European 20 Oct 2014 201 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 3-ASU/4-E 3-ASUMX/100 3-ASU/FT-EN 3-FTCU-E 3-ZA20A 3-ZA20B 3-ZA20B-E 3-ZA40A 3-ZA40A-E 3-ZA40B 3-ZA40B-E 3-BATS 3-CBLKIT1 3-CPUDR Audio Source Unit with 4 LRM slots - European 100 minute extended audio memory card Audio Source Unit with Fire Fighter Tele - European Firefighter Telephone Control Unit 20 watt Zone Amplifier, Class A 20 watt Zone Amplifier, Class B 20 watt Zone Amplifier, Class B 40 watt Zone Amplifier, Class A 40 watt Zone Amplifier, Class A 40 watt Zone Amplifier, Class B 40 watt Zone Amplifier, Class B Battery Shelf for Single 65AH Cell EST3 Extended Rail Cable Kit EST3 CPU Door Kit Certified with the following options with requirements from EN 54-2 7.8 7.13 8.3 10 Output to fire alarm devices Alarm counter Fault Signals from points Test condition Certified with the following options with requirements from EN 54-16 EST3 Repeater EST3 7.3 Audible warning 7.4 Delay(s) to entering the voice alarm condition 7.5 Phased evacuation 7.6.2 Manual silencing of the voice alarm condition 7.7.2 Manual reset of the voice alarm condition 7.9 Voice alarm condition output 8.4 Indication of faults related to voice alarm zones 9 Disablement condition 10 Voice alarm manual control 12 Emergency microphone(s) 13.14 Redundant power amplifiers Incorporating as modular units: 3-ANNCPU3 Remote Annunciator CPU with a 3-LCD 3-ANNSM Remote (repeater) Annunciator Support Module 3-LCDANN-E LCD Display and User Interface for Remote Annunciator Annunciator Back Boxes and Doors Assemblies 3-10ANN-E Remote Annunciator Back Box, 10 slots, with Door 3-10ANN/D-E Inner/Outer Door Assembly for 3-10ANN-E 10ANN/B Flush BackBox for 3-10ANN-E 10ANN/B-S Surface BackBox for 3-10ANN-E 3-6ANN-E Remote Annunciator Back Box, 6 slots, with Door 3-6ANN/D-E Inner/Outer Door Assembly for 3-6ANN-E 6ANN/B Flush BackBox for 3-6ANN-E 6ANN/B-S Surface BackBox for 3-6ANN-E 3-4ANN-E Remote Annunciator Back Box, 4 slots, with Door 3-4ANN/D-E Inner/Outer Door Assembly for 3-4ANN-E 4ANN/B Flush BackBox for 3-4ANN-E 4ANN/B-S Surface BackBox for 3-4ANN-E 3-RLCM/D-E EST3 Inner/Outer Door Assembly - Euro RLCM/B RLCM Flush BackBox RLCM/B-S RLCM Surface BackBox 3-REMICA-E Remote paging Microphone - European 3-ANNCPU3 Remote Annunciator CPU with a 3-LCD 3-ANNSM Remote (repeater) Annunciator Support Module 3-LCDANN-E LCD Display and User Interface for Remote Annunciator Incorporating as modular units: 3-SSDC1-E 3-SDDC1-E 3-AADC1-E 3-EASC-E 3-EADC-E 3-PPS/M-230-E 3-BPS/M-230-E 3-BBC/M-230-E 3-CPU3 EFM-2 202 262ab/R01 262z/01 Signature (Single), driver controller module Signature (Dual), driver controller module System Sensor driver control module Edwards (Single) Analogue driver controller module Edwards (Dual) Analogue driver controller module Primary Power Supply Booster Power Supply Booster Battery Charger Power Supply Central Processor Unit Data Communications Filter 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. 3-CAB7-E 3-CAB14-E 3-CAB21-E 7 Slot Cabinet 14 Slot Cabinet 21 Slot Cabinet 3-CAB7D(R)-E 3-CAB14D(R)-E 3-CAB21D(R)-E 3-RCC7R-E 3-RCC14R-E 3-RCC21R-E 3-LCD 3-BATSEN-E 3-BATSEN 3-BATS 3-RS485A 3-RS485B 3-RS232 3-PSMON 3-IDC8/4 3-24R 3-24Y 3-24G 3-12RY 3-12SR 3-12SY 3-12SG 3-12/S1GY 3-12/S1RY 3-12/S2Y 3-12/S2R 3-6/3S1G2Y 3-6/3S1GYR 3-6/3S2RY 3-BBCMON 3-BPSMON 3-LDSM 3-LRMF 3-RCIC Door for 7 Slot Cabinet, (R) indicates red Door for 14 Slot Cabinet, (R) indicates red Door for 21 Slot Cabinet, (R) indicates red Small Remote Battery Cabinet Medium Remote Battery Cabinet Large Remote Battery Cabinet Liquid Crystal Display, user interface Remote battery cabinet interface, temperature sensing Remote battery cabinet interface Battery Shelf Data Communication, Class A Data Communication, Class B Serial Communications Card (Printer, etc) Primary Power Supply Monitor Initiating Device Circuits/NACS 24, Red 24, Yellow 24, Green Red-over-yellow pairs 12 Switches. Red 12 Switches. Yellow 12 Switches. Green 12 Switches. Green over-yellow pairs 12 Switches. Red over-yellow pairs 24, Yellow, 12 Switches 24, Red, 12 Switches Green-over-yellow-over-yellow triads, 6 triads Green-over-yellow-over-red triads, 6 triads Red-over-yellow-over-red triads, 6 triads Booster, Battery Charger Monitor Booster Power supply Monitor Annunciator strip support module Local Rail Module Filler ASU Interconnect power and rail communication unit Certified with the following options with requirements from EN 54 Part 2: EST3 Repeater 7.8 Output to fire alarm devices 7.13 Alarm counter 8.3 Fault Signals from points 10 Test condition Incorporating as modular units: 3-RS485BA 3-ANNCPU3 3-LCDANN-E 3-ANNSM 3-REMICA 3-24Y 3-12/S1GY 3-4ANN-E(R) 3-6ANN-E(R) 3-10ANN-E(R) 20 Oct 2014 262z/01R Remote Annunciator RS485 Communications. Remote Annunciator CPU LCD Display and User Interface for Remote Annunciator Remote (repeater) Annunciator Support Module Remote paging Microphone. 24, Yellow. 12 Switches. Green over-yellow pairs. Remote Annunciator Back Box, 4 slots, with Door (R) indicates red Remote Annunciator Back Box, 6 slots, with Door (R) indicates red Remote Annunciator Back Box, 10 slots, with Door (R) indicates red 203 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Xtralis Pty Limited 4 North Drive, Virginia Park, 236-262 East Boundary Road, East Bentleigh, Victoria 3165, Australia Tel: +61 3 9936 7001, +44 (0)1442 242330 • Fax: +61 3 9936 7201 E-mail: [email protected] • Website: www.xtralis.com Certificate No: 681aq to EN 54-4: 1997 + A1: 2002 + A2: 2006 Power Supply Unit Certificated Products LPCB Ref. No. 681aq/01 VPS-215-U Power Supply Unit Note: The unit is not intended to supply power to Fire Alarm Control Panels VPS-220-U Power Supply Unit Note: The unit is not intended to supply power to Fire Alarm Control Panels 681aq/02 516-018-407 Power Supply Unit Note: The unit is not intended to supply power to Fire Alarm Control Panels 681aq/03 Zarja Elektronika d.o.o Polceva, Pot 1, 1240 Kamnik, Slovenia Tel: +386 1831 7488 • Fax: +386 1831 7551 E-mail: [email protected] • Website: www.zarja.com Certificate No: 1124a to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006 Control and indicating equipment Certificated Products NJP-400A LPCB Ref. No. 1124a/01 Analogue addressable and Conventional control and indicating equipment. Incorporating the following units: UPMO 400 NAMO 400 CPMO 400 Control and display module Power supply module Central processor module Optional modules: LIMO-Ap 400 Line module Apollo LIMO-Ko 400 Line module conventional VIMO 400 Input output module IZMO 400 Output module MRMO 400 Network module Eng_pack English language kit Slo_pack Slovenian language kit Certified with the following options with requirements from EN 54-2:1997 204 7.8 7.9.1 7.10.1 7.10.2 7.11 8.3 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Output to fire protection equipment type A Output to fire protection equipment type B Delays to the auctioning of outputs Fault signals from points Disablement of each address point Test condition Notes: 1) 2) Scope of approval does not include the operation of the network functionality. This product approval does not constitute compliance with the fire detection 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products LPCB Ref. No. and alarm NJP-401A systems requirements of EN54-13. Analogue addressable and Conventional control and indicating equipment. 1124a/02 Incorporating the following units: UPMO 400 NAMO 401 CPMO 400 Control and display module Power supply module Central processor module Optional modules: LIMO-Ap 400 LIMO-Ko 400 VIMO 400 IZMO 400 MRMO 400 Eng_pack Slo_pack Line module Apollo Line module conventional Input output module Output module Network module English language kit Slovenian language kit Certified with the following options with requirements from EN 54-2:1997 7.8 7.9.1 7.10.1 7.10.2 7.11 8.3 9.5 10 Output to fire alarm device(s) Output to fire alarm routing equipment Output to fire protection equipment type A Output to fire protection equipment type B Delays to the auctioning of outputs Fault signals from points Disablement of each address point Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. 2) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13. Zeta Alarm Systems by GLT Exports Limited Detection House, 72-78 Morfa Road, Swansea SA1 2EN, United Kingdom Tel: +44 (0)1792 455175 • Fax: +44 (0)1792 455176 E-mail: [email protected] • Website: www.gltexports.com Certificate No: 330d to EN 54: Part 2 and 4: 1997 Certificated Products Premier SX Premier SX Premier SX Premier MX 2 20 Oct 2014 2 zone conventional control and indicating equipment 4 zone conventional control and indicating equipment 8 zone conventional control and indicating equipment Certified with the following options with requirements from EN 54: Part 2: 7.8 Output to fire alarm devices 7.11 Delays to the actioning of outputs 10 Test condition 2 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition LPCB Ref. No. 330d/02 330d/03 330d/05 330d/06 205 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products Premier MX 4 Premier MX 8 Premier MX 16 Premier MX 32 Premier MX Repeater 8 Premier MX Repeater 16 Premier MX Repeater 32 4 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 16 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1629 Display board C1632 16 Zone expansion board C1652 5A Power Supply board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 16 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1629 Display board C1631 Repeater interface LPCB Ref. No. 330d/07 330d/08 330d/09 330d/10 330d/R01 330d/R02 330d/R03 Certificate No: 018c to EN 54-2 and 4:1997 206 20 Oct 2014 PART 1: SECTION 3 CONTROL AND INDICATING EQUIPMENT Certificated Products Prem1er AL 20 Oct 2014 4 loop analogue addressable control and indicating equipment Incorporating: A1579 Motherboard A1580 Display board A1585 Loop cards A1584 230V AC power supply control card A1599 Printer board Certified with the following options from EN 54-2: 1997 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition LPCB Ref. No. 018c/01 207 PART 1: SECTION 3 LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS WHY USE AN LPS 1014 APPROVED COMPANY? Even with the best equipment, fire detection and alarm systems are only effective if correctly designed, installed, commissioned and serviced. It is therefore important that specifiers select only competent firms with a proven track record to undertake the work. LPS 1014 Requirements for Certificated Fire Detection and Alarm System Firms meets these requirements in full. LPS 1014 requires one encompassing Certificate of Conformity for the project, i.e. single point responsibility, which benefits all parties concerned, i.e. the insurer, the fire brigade, the building owner, etc. It is based on BS 5839-1 and also requires the use of third party approved products. For each system specifiers should request the issue of an LPCB Certificate of Conformity as part of the contract which: certifies that the fire detection and alarm system was designed, installed and commissioned in accordance with the installation rules applied, and ensures that the system is recorded by LPCB as a certificated fire detection and alarm installation. The availability of more varied and sophisticated fire detection and alarm equipment means that it is even more important that firms listed to LPS 1014 are regularly assessed by LPCB for their competence to design, install, commission and service fire detection and alarm systems in accordance with acceptable installation rules or codes of practice. Additional offices Where a firm has additional offices, each office must meet the requirements of LPS 1014 to be eligible for certification, and is separately listed. Provisional Approval Firms with limited experience and track record can gain Provisional Approval in the LPS 1014 scheme. Their work is closely monitored by LPCB and when they have completed the requisite number of fire detection and alarm systems contracts over a period of not less than 2 years, and subject to satisfactory performance, they will be given full approval and listed in this section of the Red Book. Aarhus Fire Protection Limited Aarhus House, 4 Moss Lane, Whitefield, Manchester M45 6HG, United Kingdom Tel: +44 (0)161 767 8715 • Fax: +44 (0)161 767 8716 E-mail: [email protected] • Website: www.aarhusfire.co.uk Certificate No. CFA-187 to LPS 1014 ADT Fire and Security ADT House, Tannochside Park, Uddingston, Glasgow G71 5PH, United Kingdom Tel: +44 (0)1698 486000 • Fax: +44 (0)1698 486100 Certificate No. CFA-113 to LPS 1014 208 20 Oct 2014 PART 1: SECTION 3 LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS ADT Fire and Security Tyco Park, Grimshaw Lane, Newton Heath, Manchester M40 2WL, United Kingdom Tel: +44 (0)161 252 5500 • Fax: +44 (0)161 252 5688 Certificate No. CFA-109 to LPS 1014 ADT Fire and Security ADT House, Mucklow Hill, Halesowen, Birmingham, West Midlands B62 8DA, United Kingdom Tel: +44 (0)1212 556000 • Fax: +44 (0)1212 556100 Certificate No. CFA-108 to LPS 1014 ADT Fire and Security 180 Aztec West, Almondsbury, Bristol BS32 4TU, United Kingdom Tel: +44 (0)1454 843434 • Fax: +44 (0)1454 843484 Certificate No. CFA-107 to LPS 1014 ADT Fire and Security c/o Hindle Cockburns Ltd, Victoria Road, Leeds LS11 9SX, United Kingdom Tel: +44 (0)1132 911000 • Fax: +44 (0)1132 425933 Certificate No. CFA-110 to LPS 1014 Alberta Fire & Security Equipment Limited San Gwakkin Road, Mriehel, BKR 3000, Malta Tel: +356 21 443538 • Fax: +356 21 484077 E-mail: [email protected] • Website: www.alberta.com.mt Certificate No. CFA-177 to LPS 1014 Argus Fire Protection Company Limited Hendglade House, 46 New Road, Stourbridge, West Midlands DY8 1PA, United Kingdom Tel: +44 (0)1384 376256 • Fax: +44 (0)1384 393955 E-mail: [email protected] • Website: www.argusfire.co.uk Certificate No. CFA-148 to LPS 1014 20 Oct 2014 209 PART 1: SECTION 3 LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS Bailey Maintenance 7 Brown Lane West, Leeds LS12 6EH, United Kingdom Tel: +44 (0)113 234 3443 • Fax: +44 (0)113 222 3925 E-mail: [email protected] • Website: www.baileymaintenance.co.uk Certificate No. CFA-165 to LPS 1014 BBC Fire Protection Limited St Florian House, Ayton Road, Wymondham, Norfolk NR18 0QH, United Kingdom Tel: +44 (0)1953 857700 • Fax: +44 (0)1953 857750 E-mail: [email protected] • Website: www.bbcfire.co.uk Certificate No. CFA-126 to LPS 1014 CAMS Fire & Security PLC 6 Wedgwood Court, Wedgwood Way, Pin Green Industrial Area, Stevenage, Hertfordshire SG1 4QR, United Kingdom Tel: +44 (0)1438 740840 • Fax: +44 (0)1438 737969 E-mail: [email protected] / [email protected] • Website: www.Camsfire.co.uk Certificate No. CFA-190 to LPS1014 Chubb Fire & Security Limited 5 Canal Place, Armley Road, Leeds LS12 2DU, United Kingdom Tel: +44 (0)113 235 5131 • Fax: +44 (0)113 235 5132 E-mail: [email protected] • Website: www.chubb.co.uk Certificate No. CFA-120 to LPS 1014 Clymac Limited Cloudway Court, Belton Road, Loughborough LE11 1LW, United Kingdom Tel: +44 (0)1509 232651 • Fax: +44 (0)1509 232665 E-mail: [email protected] • Website: www.clymac.co.uk Certificate No. CFA-154 to LPS 1014 CTM Fire and Security Limited Unit 2, Osprey Place, Moss Side Industrial Estate, Leyland PR26 7EW, United Kingdom Tel: +44 (0)800 5872753 • Fax: +44 (0)1772 641227 E-mail: [email protected] • Website: www.firealarmuk.com Certificate No. CFA-156 to LPS 1014 210 20 Oct 2014 PART 1: SECTION 3 LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS Daemon Fire and Security Limited Daemon House, 41-42 Albert Road, Tamworth, Staffs B79 7JS, United Kingdom Tel: +44 (0)1827 69266 • Fax: +44 (0)1827 53584 E-mail: [email protected] Certificate No. CFA-145 to LPS 1014 Defensor Group Limited Defensor House, 15 Kingsley Street, Leicester LE2 6DY, United Kingdom Tel: +44 (0)116 244 8689 • Fax: +44 (0)116 244 8884 E-mail: [email protected] Certificate No. CFA-161 to LPS 1014 Direction Fire Limited Units 4 & 5 Fire Quarter, Blenheim Road, Epsom, Surrey KT19 9QN, United Kingdom Tel: +44 (0)1372 744499 • Fax: +44 (0)1372 741188 E-mail: [email protected] • Website: www.directionfire.co.uk Certificate No. CFA-178 to LPS 1014 EA-RS Group Limited 4 Swanbridge Industrial Park, Black Croft Road, Witham, Essex CM8 3YN, United Kingdom Tel: +44 (0)1376 503680 • Fax: +44 (0)1376 511349 E-mail: [email protected] • Website: www.rs-fire.com Certificate No. CFA-182 to LPS 1014 EMCOR Facilities Services Limited, EMCOR Specialist Services Premier House, Tollgate, Eastleigh, Hampshire SO53 3YE, United Kingdom Tel: +44 (0)2380 648028 • Fax: +44 (0)2380 648191 E-mail: [email protected] • Website: www.emcoruk.com Certificate No. CFA-151 to LPS 1014 Emico Limited Able House, 1 Figtree Hill, Hemel Hempstead, Hertfordshire HP2 5XL, United Kingdom Tel: +44 (0)1442 213111 • Fax: +44 (0)1442 236945 E-mail: [email protected] • Website: www.emico.co Certificate No. CFA-185 to LPS 1014 20 Oct 2014 211 PART 1: SECTION 3 LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS Firetecnics Systems Limited Firetecnics House, 328 St James's Road, London SE1 5JX, United Kingdom Tel: +44 (0) 20 7587 0927 • Fax: +44 (0) 20 7740 3567 E-mail: [email protected] • Website: www.firetecnics.com Certificate No. CFA-146 to LPS 1014 GBE Fire & Security (a division of GB Electronics Limited) Unit C2, Elmbridge Court, Cheltenham Road East, Gloucester GL3 1JZ, United Kingdom Tel: +44 (0)845 1220884 • Fax: +44 (0)845 1220885 E-mail: [email protected] • Website: www.gbe-uk.com Certificate No. CFA-180 to LPS 1014 Global Fire Systems Limited trading as Global Fire & Security Systems 15 The Triangle, NG2 Business Park, Queens Drive, Nottingham NG2 1AE, United Kingdom Tel: +44 (0)870 220 8211 • Fax: +44 (0)115 943 8999 E-mail: [email protected] • Website: www.globalfireandsecurity.co.uk Certificate No. CFA-189 to LPS 1014 Grainger Fire Systems Thornley House, Carrington Business Park, Carrington, Manchester M31 4XL, United Kingdom Tel: +44 (0)161 777 6700 • Fax: +44 (0)161 777 6638 E-mail: [email protected] The following location is included within the scope of certification for servicing: Unit 1A, Newton Court, Wavertree Technology Park, Wavertree, Liverpool L13 1EJ Tel: +44 (0)151 220 4068 • Fax: +44 (0)151 259 4365 Certificate No. CFA-125 to LPS 1014 Hall & Kay Fire Engineering (Ashford) Littleton Road, Ashford, Middlesex TW15 1TZ, United Kingdom Tel: +44 (0)1784 425949 • Fax: +44 (0)1784 424177 E-mail: [email protected] • Website: www.hkfire.co.uk Certificate No. CFA-147 to LPS 1014 212 20 Oct 2014 PART 1: SECTION 3 LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS I.C. Service & Maintenance Limited Unit K3 Temple Court, Knights Park, Knight Road, Strood, Kent ME2 2LT, United Kingdom Tel: +44 (0)1634 290300 • Fax: +44 (0)1634 290700 E-mail: [email protected] • Website: www.icservice.uk.com Certificate No. CFA-158 to LPS 1014 Iceberg Building Services Limited Unit 9, Honywood Business Park, Honywood Road, Basildon, Essex SS14 3HW, United Kingdom Tel: +44 (0)1268 663900 • Fax: +44 (0)1268 663909 E-mail: [email protected] • Website: www.icebergbuildingservices.co.uk Certificate No. CFA-175 to LPS 1014 Kingfell Engineering Limited PO Box 64222, Barnby Street, London NW1 2RS, United Kingdom Tel: +44 (0)203 2145252 • Fax: +44 (0)2032145253/5 E-mail: [email protected] • Website: www.kingfellengineering.com Certificate No. CFA-138 to LPS 1014 Kingfisher Security (UK) Limited trading as Kingfisher Fire & Security 1 Riverside Industrial Estate, Dogflud Way, Farnham GU9 7UG, United Kingdom Tel: +44 (0)1252 710809 • Fax: +44 (0)1252 710816 E-mail: [email protected] • Website: www.kingfishersecurity.co.uk Certificate No. CFA-176 to LPS 1014 Lloret Fire and Security Limited 24 Ullswater Crescent, Ullswater Business Park, Coulsdon, Surrey CR5 2HR, United Kingdom Tel: +44 (0) 208 410 4600 • Fax: +44 (0) 208 668 9141 E-mail: [email protected] • Website: www.lloret.co.uk Certificate No. CFA-181 to LPS 1014 M. J. Quinn Integrated Services Limited Oak House, Overbrook Lane, Knowsley Business Park, Knowsley, Merseyside L34 9FB, United Kingdom Tel: +44 (0)151 547 8800 • Fax: +44 (0)151 547 8801 E-mail: [email protected] • Website: www.mjquinn.co.uk Certificate No. CFA-137 to LPS 1014 20 Oct 2014 213 PART 1: SECTION 3 LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS M. J. Quinn Integrated Services Limited Finwell House, 26 Finsbury Square, London EC2A 1DS, United Kingdom Tel: +44 (0)207 993 0731 • Fax: +44 (0)203 757 0580 E-mail: [email protected] • Website: www.mjquinn.co.uk Certificate No. CFA-143 to LPS 1014 MECE Fire & Security Limited Courtlodge, Kemsley Street Road, Bredhurst, Gillingham, Kent ME7 3LS, United Kingdom Tel: +44 (0)1634 260607 • Fax: +44 (0)1634 260278 E-mail: [email protected] • Website: www.mecefireandsecurity.co.uk Certificate No. CFA-159 to LPS 1014 Mercury Engineering Mercury House, Sandyford Industrial Estate, Foxrock, Dublin 18, Ireland Tel: +353 1 216 3000 • Fax: +353 1 216 3006 E-mail: [email protected] • Website: www.mercury.ie Certificate No. CFA-174 to LPS 1014 MITIE Technical Facilities Management Limited 1st Floor Counting House, 53 Tooley Street, London SE1 2QN, United Kingdom Tel: +44 (0)207 022 8300 • Fax: +44 (0)207 022 8301 E-mail: [email protected] • Website: www.mitie.com Certificate No. CFA-129 to LPS 1014 MITIE Technical Facilities Management Limited (MITIE Fire and Security Systems) MITIE House, 61-63 Kepler, Lichfield Road Industrial Estate, Tamworth B79 7XE, United Kingdom Tel: +44 (0)1827 309791 • Fax: +44 (0)1827 313480 E-mail: [email protected] • Website: www.mitie.com Certificate No. CFA-163 to LPS 1014 NG Bailey Limited - Rail Division 3rd Floor Angel Building, 407 St John's Street, London EC1V 4AB, United Kingdom Tel: +44 (0)20 7843 0200 • Fax: +44 (0)20 7843 0201 E-mail: [email protected] • Website: www.ngbailey.co.uk Certificate No. CFA-186 to LPS 1014 214 20 Oct 2014 PART 1: SECTION 3 LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS PEL Services Limited Belvue Business Centre, Belvue Road, Northolt, Middlesex UB5 5QQ, United Kingdom Tel: +44 (0)20 8839 2100 • Fax: +44 (0)20 8841 1948 E-mail: [email protected] • Website: www.pel.co.uk Certificate No. CFA-179 to LPS 1014 Protec Fire Detection plc Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom Tel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273 E-mail: [email protected] • Website: www.protec.co.uk Including the following satellite offices: Unit 4, White Oak Square, London Road, Swanley, Kent BB8 1AG, United Kingdom Tel: +44 (0)845 456 5394 • Fax: +44 (0)845 456 5395 Unit 10, Fulcram 4, Solent Way, Whiteley, Fareham, Hampshire PO15 7FT, United Kingdom Tel: +44 (0)845 456 5392 • Fax: +44 (0)845 456 5393 5 Morston Court, Blakeney Way, Kingswood Lakeside, Cannock, Staffordshire WS11 8JB, United Kingdom Tel: +44 (0845 456 5398 • Fax: +44 (0845 456 5399 Unit 1, Ashfield Court, Whitehall Road, Leeds LS12 5JB, United Kingdom Tel: +44 (0)845 456 53388 • Fax: +44 (0)845 456 53389 Certificate No. CFA-132 to LPS 1014 Scotshield Limited Century House, Chapelhall Industrial Estate, Airdrie, Scotland ML6 8QH, United Kingdom Tel: +44 (0)1236 767788 • Fax: +44 (0)1236 762233 E-mail: [email protected] Including the following satellite office for service work only Unit 2, 9 Lotland Street, Inverness ML1 8QH Tel: +44 (0)1463 709637 • Fax: +44 (0)1463 709638 Certificate No. CFA-150 to LPS 1014 Sensetech Systems Limited Langdale House, 11 Marshalsea Road, London SE1 1EN, United Kingdom Tel: +44 (0)845 689 9099 • Fax: +44 (0)207 8633238 E-mail: [email protected] • Website: www.sensetechsystems.co.uk Certificate No. CFA-184 to LPS 1014 20 Oct 2014 215 PART 1: SECTION 3 LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS Siemens plc, Building Technologies, Fire Safety Division Brunel House, Sir William Siemens Square, Frimley, Camberley, Surrey GU16 8QD, United Kingdom Tel: +44 (0)1276 696000 • Fax: +44 (0)1276 696133 E-mail: [email protected] • Website: www.siemens.co.uk/buildingtechnologies Certificate No. CFA-100 to LPS 1014 Static Systems Group Plc Heath Mill Road, Wombourne, Staffordshire WV5 8AN, United Kingdom Tel: +44 (0)1902 895551 • Fax: +44 (0)1902 324969 E-mail: [email protected] • Website: www.staticsystems.co.uk Certificate No. CFA-135 to LPS 1014 T Clarke Public Limited Company 45, Moorfields, London EC2Y 9AE, United Kingdom Tel: +44 (0)207 997 7400 • Fax: +44 (0)207 997 7405 E-mail: [email protected] • Website: www.tclarke.co.uk Certificate No. CFA-188 to LPS 1014 T V F (UK) Limited 59-69 Queens Road, High Wycombe, Buckinghamshire HP13 6AH, United Kingdom Tel: +44 (0)1494 450641 • Fax: +44 (0)1494 465378 E-mail: [email protected] • Website: www.tvfltd.co.uk Certificate No. CFA-128 to LPS 1014 Thameside Fire Protection Co. Limited Unit 4, Sovereign Business Park, Cranes Farm Road, Basildon, Essex SS14 3JD, United Kingdom Tel: +44 (0)1268 597999 • Fax: +44 (0)1268 597998 E-mail: [email protected] • Website: www.thamesidefire.co.uk Certificate No. CFA-171 to LPS 1014 Trinity Fire and Security Systems Ltd (Abingdon) 180D Park Drive Milton, Milton Park, Abingdon, Oxfordshire OX14 4SE, United Kingdom Tel: +44 (0)1235 862456 • Fax: +44 (0)1235 834450 E-mail: [email protected] • Website: www.trinityprotection.co.uk Certificate No. CFA-168 to LPS 1014 216 20 Oct 2014 PART 1: SECTION 3 LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS Trinity Fire and Security Systems Ltd (Exeter) Little Bridge Business Park, Oil Mill Lane, Clyst St.Mary, Exeter, Devon EX5 1AG, United Kingdom Tel: +44 (0)1392 874455 • Fax: +44 (0)1392 875546 E-mail: [email protected] • Website: www.trinityprotection.co.uk Certificate No. CFA-160 to LPS 1014 Trinity Fire and Security Systems Ltd (Honiley) Unit C15b, Holly Farm Business Park, Honiley, Warwickshire CV8 INP, United Kingdom Tel: +44 (0)1926 485080 • Fax: +44 (0)1926 485090 E-mail: [email protected] • Website: www.trinityprotection.co.uk Certificate No. CFA-167 to LPS 1014 Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited) Mucklow Office Park, Mucklow Hill, Halesowen, West Midlands B62 8DA, United Kingdom Tel: +44 (0)121 255 6000 • Fax: +44 (0)121 255 6100 Website: www.tycofis.com Certificate No. CFA-103 to LPS 1014 Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited) 1610 Park Avenue, Aztec West, Almondsbury, Bristol BS32 4UA, United Kingdom Tel: +44 (0)1454 240071 • Fax: +44 (0)1454 626443 Website: www.tycofis.com Certificate No. CFA-170 to LPS 1014 Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited) Tyco House, 57-63 Farnham Road, Slough, Berkshire SL1 3TN, United Kingdom Tel: +44 (0)1753 574111 • Fax: +44 (0)1753 824226 Website: www.tycofis.com Certificate No. CFA-157 to LPS 1014 20 Oct 2014 217 PART 1: SECTION 3 LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS Vipond Fire Protection Limited 10-12 Glenfield Road, Kelvin Industrial Estate, East Kilbride, Lanarkshire G75 0RA, United Kingdom Tel: +44 (0)1355 2375 25/80/88 • Fax: +44 (0)1355 263399 E-mail: [email protected] • Website: www.vipondfire.co.uk Certificate No. CFA-173 to LPS 1014 218 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS There are many types of detectors on the market designed to work on different principles and fire parameters (e.g. smoke, flame radiation, convective heat etc). The selection of a detector for a particular area or application should be based on a number of factors including the following: The nature of the fire hazard The speed of response required The need to minimize false alarms There are other factors to be taken into account such as architecture of the building, ease of maintenance and cost, etc. Guidance on the selection of appropriate types of detectors should be sought from the applicable installation rule or code of practice (e.g. BS 5839-1). Where a particular type of detector is not covered by the installation rule or code of practice then guidance should be sought from the manufacturer’s literature. In any case, account should be given to the notes or limitations given with the listed detector in this section. This section lists fire detectors approved for use in fire detection and fire alarm systems in buildings. The initial approval and continued approval processes for detectors are outlined in scheme document SD021. The list includes detectors certified to recognised standards or to special test schedules which are developed by LPCB for detector types where suitable standards are not available or were not available at the time of the evaluation. Products listed in this section have been approved to: EN 54-5: 2000 Heat detectors - point detectors EN 54-5: 2000 + A1: 2002 Heat detectors - point detectors EN 54-7: 2000 Smoke detectors - point detectors using scattered light, transmitted light or ionisation EN 54-7 :2000 +A1: 2002 and A2: 2006 Smoke detectors - point detectors using scattered light, transmitted light or ionisation EN 54-10: 2002 Flame detectors - point detectors EN 54-10: 2002 + A1: 2005 Flame detectors - point detectors EN 54-12: 2002 Smoke detectors - line detectors using an optical light beam EN 54-20: 2006 Aspirating smoke detectors EN 54-25: 2008 Components using radio links ISO7240-5: 2003 Point -type heat detectors ISO7240-6: 2004 Carbon monoxide fire detectors using electro-chemical cells ISO7240-7: 2003 Point-type smoke detectors using scattered light, transmitted light or ionization ISO7240-12: 2005 Line type smoke detectors using transmitting light beam ISO7240-15: 2004 Multisensor fire detectors ISO 7240-6: 2008 Carbon monoxide fire detectors using electro-chemical cells and heat sensors. CEA 4021: 1999 Requirements and test methods for multisensor detectors, which respond to smoke and heat, and smoke detectors with more than one smoke sensor CEA 4021: 2003 Requirements and test methods for multisensor detectors, which respond to smoke and heat, and smoke detectors with more than one smoke sensor LPS 1265-1.1: 2005 Requirements and Testing Procedures for the LPCB Approval and Listing of Carbon Monoxide Fire Detectors Using Electrochemical Cells LPS 1274-1.0: 2005 Testing Procedures for the LPCB Approval and Listing of Carbon Monoxide /Heat Multisensor Fire Detectors Using Electrochemical Cells LPS 1279-1.0: 2006 Testing Procedures for the LPCB Approval and Listing of Point Multisensor Fire Detectors using Optical or Ionization Smoke Sensors and Electrochemical Cell CO Sensors and, optionally, Heat Sensors LPS 1280-1.0: 2007 Testing Procedures for the LPCB Approval and Listing of Duct Smoke Detectors using Point Smoke Detectors 20 Oct 2014 219 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Approval can also be obtained for other detection principles not detailed above. In such circumstances, LPCB can develop test criteria to evaluate products, which in time may be used for the development of standards. Audit: Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: 1. EN 54-5: 2000 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 30 June 2005. It is therefore recommended that heat detectors are certificated to EN 54-5: 2000 + A1: 2002 2. EN 54-7: 2000 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 30 June 2005. It is therefore recommended that smoke detectors are certificated to EN 54-7: 2000 + A1: 2002 and A2: 2006 3. EN 54-10: 2002 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 September 2008. It is therefore recommended that flame detectors are certificated to EN 54- 10: 2002 + A1: 2005 4. EN 54-12: 2002 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 31 December 2005. It is therefore recommended that beam detectors are certificated to EN 54- 12: 2002 5. EN 54-25: 2008 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 March 2011. It is therefore recommended that radio link components are certificated to EN 54- 25: 2008 6. CEA 4021: 2003 supersedes CEA 4021: 1999 which was withdrawn in June 2003 (i.e. at the same time as the national versions of EN 54-5: 1976 and EN 54-7: 1982 were officially withdrawn and replaced with EN 54- 5: 2000 and EN 54-7: 2000). 7. EN 54-20: 2006 supersedes CEA 4022: 1999 which should have been withdrawn in 2009. EN 54-20: 2006 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 July 2009. It is therefore recommended that aspirating detectors are certificated to EN 54-20: 2006. 8. The bases with which a detector has been evaluated and shown to meet the relevant standards are listed with each detector. Bases are not approved/certificated in their own right unless they are combined with another device (e.g. short circuit isolator or sounder). 9. Since LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly. ADI International ADI International Espana, C/Vivero 5, 28040 Madrid, Spain Tel: +34 91 102 590 • Fax: +34 91 535 0081 E-mail: [email protected] • Website: www.ademco.es Certificate No: 199u to EN 54-12: 2002 Beam Detectors Certificated Products 8200R 220 Conventional optical beam detector Note: LPCB Ref. No. 199u/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 8200RS LPCB Ref. No. 1. Meets the requirements for EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 & Acclimate levels 1 & 2 Conventional optical beam detector with self test facility Note: 1. Meets the requirements for EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 & Acclimate levels 1 & 2 199u/02 Advanced Electronics Limited 34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United Kingdom Tel: +44 (0)1670 707 111 • Fax: +44 (0)1670 707 222 E-mail: [email protected] • Website: www.Advel.co.uk Certificate No: 928a-(cl-5) to EN54-5: 2000 + A1: 2002 and EN 54 -17: 2005 Certificate No: 928d-(cl-5) to EN 54-5: 2000 + A1: 2002 Certificate No: 928j-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008 Point Heat Detectors Certificated Products 20-V350-ADV 20-LV350-ADV 20-AS3500-ADV 20-SG350-ADV Bases 20-AB100-ADV 20-VB100-ADV 20-ABR100-ADV 20-ABDR100-ADV 20-ABS100-ADV 20-ABSR100-ADV 20-ABSRD100-ADV WAB100 Analogue addressable Class P heat detector with short circuit isolator (20-AB100-ADV base) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B. Analogue addressable Class P, temperature detector (20-VB100-ADV and 20-AB100ADV bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B. Conventional Class P, heat detector (20-AB100-ADV, 20-ABR100-ADV, 20-ABDR100-ADV, 20-ABS100-ADV, 20-ABSR100-ADV and 20-ABSRD100-ADV) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B. Wireless heat detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1R 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928a/01 928d/01 928d/02 928j/01 Mounting base Mounting base (with link resistor) Universal adaptor base with resistor Universal adaptor base with resistor and Schottky diode Deep adaptor base Deep adaptor base with resistor Deep adaptor base with resistor and Schottky diode Wireless adaptor base Certificate No: 928b-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005 Certificate No: 928e-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products 20-V100-ADV Analogue addressable photoelectric smoke detector with short circuit isolator (20-AB100ADV base) LPCB Ref. No. 928b/01 Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: 20 Oct 2014 221 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable optical smoke detector (20-VB100-ADV and 20-AB100-ADV bases) 20-LV100-ADV Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Conventional photo smoke detector (20-AB100-ADV, 20-ABR100-ADV, 20-ABDR100ADV, 20-ABS100-ADV, 20-ABSR100-ADV and 20-ABSRD100-ADV) 20-AS1000-ADV Bases 20-AB100-ADV 20-VB100-ADV 20-ABR100-ADV 20-ABDR100-ADV 20-ABS100-ADV 20-ABSR100-ADV 20-ABSRD100-ADV 928e/01 928e/02 Mounting base Mounting base (with link resistor) Universal adaptor base with resistor Universal adaptor base with resistor and Schottky diode Deep adaptor base Deep adaptor base with resistor Deep adaptor base with resistor and Schottky diode Certificate No: 928c-(cl-5) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA4021: 2003 Certificate No: 928f-(cl-5) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Multi-sensor detectors Certificated Products 20-V200-ADV Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (20-AB100-ADV base) Notes: 1. 2. 3. 20-LV200-ADV 222 LPCB Ref. No. 928c/01 Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable photo thermal multisensor (20-VB100-ADV and 20-AB100-ADV bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: 928f/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Bases 20-AB100-ADV 20-VB100-ADV Mounting base Mounting base (with link resistor) Certificate No: 928k-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008 Smoke Detectors Certificated Products 20-SG100-ADV Wireless optical smoke detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-7 in the normal sensitivity setting 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928k/01 Bases: WAB100 Wireless Adaptor Base Certificate No: 928m-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003 Multi-Criteria Detectors Certificated Products 20-SG200-ADV Wireless multi-criteria detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1 2. Meets the requirements of EN 54-7 in the normal sensitivity setting 3. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928m/01 Bases: WAB100 Wireless Adaptor Base Advantronic Systems S.L. C/Yunque 9 Nave B1, Tres Cantos, Madrid 28760, Spain Tel: +34 91 806 2343 • Fax: +34 91 803 1171 E-mail: [email protected] • Website: www.advantronic.es Certificate No: 928a-(cl-3) to 54-5: 2000 + A1: 2002 and EN 54 -17: 2005 Certificate No: 928d-(cl-3) to EN 54-5: 2000 + A1: 2002 Certificate No: 928j-(cl-2) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008 Point Heat Detectors Certificated Products AT120A AT120AS AT120CM ATW120A 20 Oct 2014 Analogue addressable Class P heat detector with short circuit isolator (BA100 base) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B. Analogue addressable Class P, temperature detector (BA100 base) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B. Conventional Class P, heat detector (BA100 and BA101 bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B. Wireless heat detector (WAB100 base) LPCB Ref. No. 928a/01 928d/01 928d/02 928j/01 223 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. Notes: 1. Meets the requirements of EN 54-5 for Class A1R 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery Bases BA100 BA101 WAB100 Mounting base Deep adaptor base Wireless Adaptor Base Certificate No: 928b-(cl-3) to 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005 Certificate No: 928e-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products AT110A Analogue addressable photoelectric smoke detector with short circuit isolator (BA100 base) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable optical smoke detector (BA100 base) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Conventional photo smoke detector (BA100 and BA101 bases) AT110AS AT110CM Bases BA100 BA101 LPCB Ref. No. 928b/01 928e/01 928e/02 Mounting base Deep adaptor base Certificate No: 928c-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA4021: 2003 Certificate No: 928f-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Multi-sensor Detectors Certificated Products AT130A Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (BA100 base) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low AT130AS Analogue addressable photo thermal multisensor (BA100 base) Notes: 224 LPCB Ref. No. 928c/01 928f/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. 1. 2. 3. Bases BA100 Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Mounting base Certificate No: 928k-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008 Smoke Detectors Certificated Products ATW110A Wireless optical smoke detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-7 in the normal sensitivity setting 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928k/01 Bases: WAB100 Wireless Adaptor Base Certificate No: 928m-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003 Multi-Criteria Detectors Certificated Products ATW130A Wireless multi-criteria detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1 2. Meets the requirements of EN 54-7 in the normal sensitivity setting 3. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928m/01 Bases: WAB100 Wireless Adaptor Base AGNI Devices PVT Ltd C-55 DSIDC Ind Complex, Tilak Vihar, Tilak Nagar, New Delhi 110018, India Tel: +91 11 28335624 E-mail: [email protected] Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006 20 Oct 2014 225 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Smoke Detectors Certificated Products AD338-2L Conventional photoelectric smoke detector (AD300 base) LPCB Ref. No. 550a/05 AD300 Standard Base Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products AD338-2HL Conventional photo-thermal class A1R detector (AD300 base) Note: Meets the requirements of EN54-5: 2000 class A1R at pre-set sensitivity LPCB Ref. No. 550b/06 Base: AD300 standard base Certificate No: 550c to EN54-5: 2000 + A1: 2002 Heat Detectors Certificated Products AD318-2L Conventional A1R rate of rise heat detector (AD300 base) LPCB Ref. No. 550c/08 Base: AD300 standard base Aguilera Electronica S.L C / Julian Camarillo 26, Madrid 28037, Spain Tel: +34 917545511 • Fax: +34 917545098 E-mail: [email protected] Certificate No: 512d-(cl-2) to EN 54-5: 2000 + A1: 2002 Point Heat Detectors Certificated Products AE/C5-TV Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base) LPCB Ref. No. 512d/04 Bases: P/N854001 4-Wire detector base Certificate No: 512a-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products AE/C5-OP Conventional 2 wire photoelectric smoke detector with remote LED output (P/N854001 base) LPCB Ref. No. 512a/02 Bases: P/N854001 4-Wire detector base Certificate No: 512b-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A1: 2002 & CEA 4021: 2003 Multi-criteria Detectors Certificated Products AE/C5-OPT 226 Conventional 2 wire photoelectric smoke and heat detector with remote LED output (P/N854001 base) LPCB Ref. No. 512b/02 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Bases: P/N854001 4 Wire detector base Alarm Supply Pte Ltd 63 Jalan Pemimpin, 03-07 Pemimpin Industrial Building, Singapore 577219, Singapore Tel: +65 625 83445 • Fax: +65 625 86428 Certificate No: 512a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products EA318-2 EA318-2L Conventional 2 wire photoelectric smoke detector (P/N852001 base) Conventional 2 wire photoelectric smoke detector with remote LED output (E300-Base) LPCB Ref. No. 512a/01 512a/02 Bases: E300-Base 4-wire detector base P/N852001 2-wire detector base Certificate No: 512d-(cl-1) to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products EA323-2 EA323-2L/A2R Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector (P/N852001 base) Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (E300-Base) LPCB Ref. No. 512d/02 512d/04 Bases: E300-Base 4-wire detector base P/N852001 2-wire detector base AMPAC Technologies PTY Ltd 7 Ledgar Road, Balcatta 6021, Australia Tel: +618 (9242) 3333 • Fax: +618 (9242) 3334 E-mail: [email protected] • Website: www.ampac.net Certificate No: 010ar to EN 54-5 : 2000 + A1: 2002 Certificate No: 010p-(cl-2) to EN54-5: 2000 + A1: 2002 Heat Detectors Certificated Products 55000-465AMP 55000-475AMP 55000-122AMP 55000-127AMP 55000-132AMP 55000-137AMP 20 Oct 2014 Analogue addressable Class A2S heat detector (45681-505AMP mounting bases) Analogue addressable Classheat detector (45681-505AMP mounting bases) Series 65 Conventional Class A1R heat detector - Standard (45681-200AMP mounting base) 1 Meets the requirements of EN54: Part 5 - Class A1R Series 65 Conventional Class BR heat detector - Standard (45681-200AMP mounting base) 1 Meets the requirements of EN54: Part 5 - Class BR Series 65 Conventional Class CR heat detector - Standard (45681-200AMP mounting base) 1 Meets the requirements of EN54: Part 5 - Class CR Series 65 Conventional Class CS heat detector - Standard (45681-200AMP mounting base) 1 Meets the requirements of EN54: Part 5 - Class CS LPCB Ref. No. 010ar/01 010ar/02 010p/06 010p/09 010p/12 010p/15 227 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Bases: 45681-505AMP Negative switching isolating base 45681-200AMP Series 60/65 mounting base 45681-201AMP Series 60/65 diode mounting base 45681-245AMP Series 65 relay mounting base 45681-246AMP Series 65 auxiliary relay mounting base 45681-247AMP Series 65 EOL 12 Volt mounting base 45681-248AMP Series 65 EOL 24 Volt mounting base Notes: 1 Also certificated for use with 45681-245AMP, 45681-246AMP, 45681-247AMP, 45681-248AMP and 45681-201AMP mounting bases. Certificate No: 010as to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 010q-(cl-2) to EN54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products 55000-665AMP 55000-217AMP 55000-220AMP 55000-317AMP Analogue addressable optical smoke detector (45681-505AMP mounting bases) Series 65 Conventional ionisation smoke detector - Standard (45681-200AMP mounting base) 1 Series 65 Conventional integrating ionisation smoke detector - Standard (45681-200AMP mounting base) 1 Series 65 Conventional optical smoke detector - Standard (45681-200AMP mounting base) 1 LPCB Ref. No. 010as/01 010q/06 010q/09 010q/12 Bases: 45681-505AMP Negative switching isolating base 45681-200AMP Series 60/65 mounting base 45681-201AMP Series 60/65 diode mounting base 45681-245AMP Series 65 relay mounting base 45681-246AMP Series 65 auxiliary relay mounting base 45681-247AMP Series 65 EOL 12 Volt mounting base 45681-248AMP Series 65 EOL 24 Volt mounting base Notes: 1 Also certificated for use with 45681-245AMP, 45681-246AMP, 45681-247AMP, 45681-248AMP and 45681-201AMP mounting bases. Certificate No: 010at to EN 54-17: 2005 Negative Switching Isolating Base Certificated Products 45681-505AMP Negative switching isolating base LPCB Ref. No. 010at/01 Certificate No: 010m-(cl-1) to EN54-7: 2001 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Certificate No: 010aq-(cl-1) to EN 54-5: 2000 + A1: 2002 + LPS 1274: 2005 + LPS 1265: 2004 Multi-Sensor/Multi-Criteria Detectors Certificated Products 58000-305AMP Analogue addressable CO/heat multisensor detector (45681-210AMP, standard intelligent mounting base) Notes: 1. Mode 1 Mode 2 Mode 3 Mode 4 Mode 5 2. 2002 228 LPCB Ref. No. 010aq/01 Approved with the following mode configurations:30 ppm with high thermal enhancement (most sensitive) 33 ppm with CO only 40 ppm with low thermal enhancement (nominal sensitivity) 45 ppm with high thermal enhancement (least sensitive) heat onlyA1R Mode 1 , 3, and 4 are approved to LPS1274:2005 and EN 54-5:2000 + A1: 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. 3. 4. Mode 2 is approved to LPS 1265:2004 Mode 5 is approved to EN 54-5:2000 + A1:2002 Conditions of approval include; 55000-885AMP a) The 58000-305AMP should only be installed in accordance with the manufacturers recommendations. b) The 58000-305AMP should not be set only as a carbon monoxide fire detector where there is a specific risk of rapid burning/flaming fires. c) Refer to technical publication MAN3038-1 for limitations on the use of carbon monoxide fire detection. Analogue addressable multisensor detector (45681-209AMP and 45681-210AMP mounting base)Approved with Apollo XP95 and S90 digital communication protocols that have been configured for the XP95 multisensor detector in accordance with manufacturers instructions. 010m/01 Bases: 45681-209AMP XP95/Discovery standard deep mounting base 45681-210AMP XP95 mounting base Apollo Fire Detectors Limited 36 Brookside Road, Havant, Hampshire PO9 1JR, United Kingdom Tel: +44 (0)2392 492412 • Fax: +44 (0)2392 492754 E-mail: [email protected] Sales Enquiries Germany Apollo Deutschland GmbH Tel: +49 5241 330 60 • Fax: +49 5241 330 629 E-mail: [email protected] Sales Enquiries Spain Apollo Espana Tel: +34 627 988 061 • Fax: +34 949 335 289 E-mail: [email protected] Sales Enquiries China Apollo Fire Detectors Limited, Shanghai representative office Tel: +86 21 5237 0922 • Fax: +86 21 5237 0920 E-mail: [email protected] Certificate No: 010r to EN 54: Part 5: 2000 Certificate No: 010ab to EN 54-5: 2000 + A1: 2002 Certificate No: 010p to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products XPA-HT-11170-APO XPA-HT-11171-APO 20 Oct 2014 Xpander addressable radio linked Class A1R heat detector (XPA-WB-10022-APO mounting base) Notes: 1) Meets the requirements of EN 54-5 for Class A1R. 2) The complete radio base/detector combination is available as Apollo Part No.: XPACB-11170-APO. 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells. 4) The radio link functionality of this device is not included within the scope of approval. Xpander addressable radio linked Class CS heat detector (XPA-WB-10022-APO LPCB Ref. No. 010ab/01 010ab/02 229 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 58000-400 55000-120 55000-121 55000-122 55000-125 55000-126 55000-127 55000-130 55000-131 55000-132 55000-135 55000-136 55000-137 230 LPCB Ref. No. mounting base) Notes: 1) Meets the requirements of EN 54-5 for Class CS. 2) The complete radio base/detector combination is available as Apollo Part No.: XPACB-11171-APO. 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells. 4) The radio link functionality of this device is not included within the scope of approval. Discovery Analogue addressable heat detector (45681-209 and 45681-210 mounting base) Note: Meets the requirements of EN 54: Part 5 for the following settings Class A1R in mode 1 and in conventional mode. Class A2 in mode 2 and in conventional mode. Class A2S in mode 3 and in conventional mode. Class CR in mode 4 and in conventional mode. Class CS in mode 5 and in conventional mode. Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols when the Discovery heat detector has been configured in accordance with manufacturer's instructions. Series 65 Conventional Class A1R heat detector - Flashing LED/Reed switch (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class A1R Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Series 65 Conventional Class A1R heat detector - Flashing LED (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class A1R Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Series 65 Conventional Class A1R heat detector - Standard (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class A1R Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Series 65 Conventional Class BR heat detector - Flashing LED/Reed switch (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class BR Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Series 65 Conventional Class BR heat detector - Flashing LED (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class BR Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Series 65 Conventional Class BR heat detector - Standard (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class BR Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Series 65 Conventional Class CR heat detector- Flashing LED/Reed switch (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class CR Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Series 65 Conventional Class CR heat detector - Flashing LED (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class CR Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Series 65 Conventional Class CR heat detector - Standard (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class CR Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Series 65 Conventional Class CS heat detector - Flashing LED/Reed switch (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class CS Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Series 65 Conventional Class CS heat detector - Flashing LED (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class CS Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Series 65 Conventional Class CS heat detector - Standard (45681-200 mounting base) 010p/03 010p/04 010p/05 010p/06 010p/07 010p/08 010p/09 010p/10 010p/11 010p/12 010p/13 010p/14 010p/15 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 55000-400 55000-401 55000-420 55000-440 Orbis Class A1R Orbis Class A2S Orbis Class BR LPCB Ref. No. Note: Meets the requirements of EN 54: Part 5 - Class CS Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases XP95 Analogue addressable Class A2S heat detector 45681-209 and 45681-210 mounting base) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions. XP95 Analogue addressable Class CS heat detector 45681-209 and 45681-210 mounting base) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions. XP95 Analogue addressable Class A2S heat detector 45681-209 and 45681-210 mounting base) Certificated with Apollo Discovery, XP95, and S90 digital communications protocol configured for the Discovery heat detector in accordance with manufacturers instructions. XP95 IS Analogue addressable intrinsically safe Class A2S heat detector (45681-215 mounting base) Certified with Apollo Series 90 and XP95 digital communications protocol Heat detectors with Apollo Approval Reference* 00001 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base) ORB-HT-11001-APO Orbis class A1R heat detector with SensAlert and FasTest ORB-HT-11013-APO Orbis class A1R heat detector with Flashing LED, SensAlert and FasTest OAX-HT-11019-APO Orbis class A1R heat detector with SensAlert OPX-HT-11025-APO Orbis class A1R heat detector with SensAlert OEX-HT-11037-APO Orbis class A1R heat detector with Flashing LED and SensAlert OIX-HT-11043-APO Orbis class A1R heat detector with Flashing LED and SensAlert OMX-HT-11049-APO Orbis class A1R heat detector with SensAlert OSX-HT-11061-APO Orbis class A1R heat detector with Flashing LED and SensAlert OMX-HT-11071-APO Orbis class A1R heat detector with Flashing LED and SensAlert OAX-HT-11077-APO Orbis class A1R heat detector with Flashing LED and SensAlert OEX-HT-11089-APO Orbis class A1R heat detector with SensAlert OSX-HT-11095-APO Orbis class A1R heat detector with SensAlert OPX-HT-11125-APO Orbis class A1R heat detector with Flashing LED and SensAlert OLX-HT-11137-APO Orbis class A1R heat detector with SensAlert and FasTest Heat detectors with Apollo Approval Reference* 00002 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base) ORB-HT-11002-APO Orbis class A2S heat detector with SensAlert and FasTest ORB-HT-11014-APO Orbis class A2S heat detector with Flashing LED, SensAlert and FasTest OAX-HT-11020-APO Orbis class A2S heat detector with SensAlert OPX-HT-11026-APO Orbis class A2S heat detector with SensAlert OEX-HT-11038-APO Orbis class A2S heat detector with Flashing LED and SensAlert OIX-HT-11044-APO Orbis class A2S heat detector with Flashing LED and SensAlert OMX-HT-11050-APO Orbis class A2S heat detector with SensAlert OSX-HT-11062-APO Orbis class A2S heat detector with Flashing LED and SensAlert OMX-HT-11072-APO Orbis class A2S heat detector with Flashing LED and SensAlert OAX-HT-11078-APO Orbis class A2S heat detector with Flashing LED and SensAlert OEX-HT-11090-APO Orbis class A2S heat detector with SensAlert OSX-HT-11096-APO Orbis class A2S heat detector with SensAlert OPX-HT-11126-APO Orbis class A2S heat detector with Flashing LED and SensAlert OLX-HT-11138-APO Orbis class A2S heat detector with SensAlert and FasTest Heat detectors with Apollo Approval Reference* 00003 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base) 010p/20 010p/21 010p/22 010p/23 010r/01 010r/02 010r/03 ORB-HT-11003-APO Orbis class BR heat detector with SensAlert and FasTest ORB-HT-11015-APO Orbis class BR heat detector with Flashing LED, SensAlert and FasTest OAX-HT-11021-APO Orbis class BR heat detector with SensAlert OPX-HT-11027-APO Orbis class BR heat detector with SensAlert OEX-HT-11039-APO Orbis class BR heat detector with Flashing LED and SensAlert OIX-HT-11045-APO Orbis class BR heat detector with Flashing LED and SensAlert OMX-HT-11051-APO Orbis class BR heat detector with SensAlert OSX-HT-11063-APO Orbis class BR heat detector with Flashing LED and SensAlert OMX-HT-11073-APO Orbis class BR heat detector with Flashing LED and SensAlert OAX-HT-11079-APO Orbis class BR heat detector with Flashing LED and SensAlert OEX-HT-11091-APO Orbis class BR heat detector with SensAlert OSX-HT-11097-APO Orbis class BR heat detector with SensAlert OPX-HT-11127-APO Orbis class BR heat detector with Flashing LED and SensAlert OLX-HT-11139-APO Orbis class BR heat detector with SensAlert and FasTest 20 Oct 2014 231 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products Orbis Class BS Orbis Class CR Orbis Class CS Orbis Class A1S Orbis IS Class A1R Orbis IS Class A2S Heat detectors with Apollo Approval Reference* 00004 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base ORB-HT-11004-APO Orbis class BS heat detector with SensAlert and FasTest ORB-HT-11016-APO Orbis class BS heat detector with Flashing LED, SensAlert and FasTest OAX-HT-11022-APO Orbis class BS heat detector with SensAlert OPX-HT-11028-APO Orbis class BS heat detector with SensAlert OEX-HT-11040-APO Orbis class BS heat detector with Flashing LED and SensAlert OIX-HT-11046-APO Orbis class BS heat detector with Flashing LED and SensAlert OMX-HT-11052-APO Orbis class BS heat detector with SensAlert OSX-HT-11064-APO Orbis class BS heat detector with Flashing LED and SensAlert OMX-HT-11074-APO Orbis class BS heat detector with Flashing LED and SensAlert OAX-HT-11080-APO Orbis class BS heat detector with Flashing LED and SensAlert OEX-HT-11092-APO Orbis class BS heat detector with SensAlert OSX-HT-11098-APO Orbis class BS heat detector with SensAlert OPX-HT-11128-APO Orbis class BS heat detector with Flashing LED and SensAlert OLX-HT-11140-APO Orbis class BS heat detector with SensAlert and FasTest Heat detectors with Apollo Approval Reference* 00005 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base ORB-HT-11005-APO Orbis class CR heat detector with SensAlert and FasTest ORB-HT-11017-APO Orbis class CR heat detector with Flashing LED, SensAlert and FasTest OAX-HT-11023-APO Orbis class CR heat detector with SensAlert OPX-HT-11029-APO Orbis class CR heat detector with SensAlert OEX-HT-11041-APO Orbis class CR heat detector with Flashing LED and SensAlert OIX-HT-11047-APO Orbis class CR heat detector with Flashing LED and SensAlert OMX-HT-11053-APO Orbis class CR heat detector with SensAlert OSX-HT-11065-APO Orbis class CR heat detector with Flashing LED and SensAlert OMX-HT-11075-APO Orbis class CR heat detector with Flashing LED and SensAlert OAX-HT-11081-APO Orbis class CR heat detector with Flashing LED and SensAlert OEX-HT-11093-APO Orbis class CR heat detector with SensAlert OSX-HT-11099-APO Orbis class CR heat detector with SensAlert OPX-HT-11129-APO Orbis class CR heat detector with Flashing LED and SensAlert OLX-HT-11141-APO Orbis class CR heat detector with SensAlert and FasTest Heat detectors with Apollo Approval Reference* 00006 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base ORB-HT-11006-APO Orbis class CS heat detector with SensAlert and FasTest ORB-HT-11018-APO Orbis class CS heat detector with Flashing LED, SensAlert and FasTest OAX-HT-11024-APO Orbis class CS heat detector with SensAlert OPX-HT-11030-APO Orbis class CS heat detector with SensAlert OEX-HT-11042-APO Orbis class CS heat detector with Flashing LED and SensAlert OIX-HT-11048-APO Orbis class CS heat detector with Flashing LED and SensAlert OMX-HT-11054-APO Orbis class CS heat detector with SensAlert OSX-HT-11066-APO Orbis class CS heat detector with Flashing LED and SensAlert OMX-HT-11076-APO Orbis class CS heat detector with Flashing LED and SensAlert OAX-HT-11082-APO Orbis class CS heat detector with Flashing LED and SensAlert OEX-HT-11094-APO Orbis class CS heat detector with SensAlert OSX-HT-11100-APO Orbis class CS heat detector with SensAlert OPX-HT-11130-APO Orbis class CS heat detector with Flashing LED and SensAlert OLX-HT-11142-APO Orbis class CS heat detector with SensAlert and FasTest Heat detectors with Apollo Approval Reference* 00009 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base ORB-HT-11166-APO Orbis class A1S heat detector with SensAlert and FasTest ORB-HT-11167-APO Orbis class A1S heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50001 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base ORB-HT-51145-APO Orbis intrinsically safe class A1R heat detector with SensAlert and FasTest ORB-HT-51146-APO Orbis intrinsically safe class A1R heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50002 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base LPCB Ref. No. 010r/04 010r/05 010r/06 010r/07 010r/08 010r/09 ORB-HT-51147-APO Orbis intrinsically safe class A2S heat detector with SensAlert and FasTest 232 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products Orbis IS Class BR Orbis IS Class BS Orbis IS Class CR Orbis IS Class CS Orbis IS Class A1S LPCB Ref. No. ORB-HT-51148-APO Orbis intrinsically safe class A2S heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50003 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base ORB-HT-51149-APO Orbis intrinsically safe class BR heat detector with SensAlert and FasTest ORB-HT-51150-APO Orbis intrinsically safe class BR heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50004 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base ORB-HT-51151-APO Orbis intrinsically safe class BS heat detector with SensAlert and FasTest ORB-HT-51152-APO Orbis intrinsically safe class BS heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50005 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base ORB-HT-51153-APO Orbis intrinsically safe class CR heat detector with SensAlert and FasTest ORB-HT-51154-APO Orbis intrinsically safe class CR heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50006 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base) ORB-HT-51155-APO Orbis intrinsically safe class CS heat detector with SensAlert and FasTest ORB-HT-51156-APO Orbis intrinsically safe class CS heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50009 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base 010r/10 010r/11 010r/12 010r/13 010r/14 ORB-HT-51157-APO Orbis intrinsically safe class A1S heat detector with SensAlert and FasTest ORB-HT-51158-APO Orbis intrinsically safe class A1S heat detector with Flashing LED, SensAlert and FasTest Bases: 45681-200 Series 60 mounting base 45681-200 Series 60/65 Mounting Base 45681-201 Series 60 diode mounting base 45681-201 Series 60/65 Diode Mounting Base 45681-207 Series 60 intrinsically safe mounting base 45681-209 XP95/Discovery standard deep mounting base 45681-210 XP95 mounting base 45681-215 XP95 intrinsically safe mounting base 45681-245 Series 65 Relay mounting base 45681-246 Series 65 Auxiliary relay mounting base 45681-247 Series 65 EOL 12 Volt mounting base 45681-248 Series 65 EOL 24 Volt mounting base TimeSaver bases with Apollo Approval Reference* OB TimeSaver LX bases with Apollo Approval Reference* OL TimeSaver diode bases with Apollo Approval Reference* OD TimeSaver relay bases with Apollo Approval Reference* OR TimeSaver LX diode bases with Apollo Approval Reference* DX TimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking) TimeSaver deep bases with Apollo Approval Reference* EB: ORB-MB-00019-APO TimeSaver deep base ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207) ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201) XPA-WB-10022-APO Radio link mounting base** * The Apollo ‘Approval Reference Number’ identifies a group of detectors that all have the same physical construction, but have features enabled or disabled via their software, and/or regional marking variations. **Base manufactured by EMS 20 Oct 2014 233 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 010q to EN 54: Part 7: 2000 Certificate No: 010s to EN 54: Part 7: 2000 Certificate No: 010ac to EN 54-7: 2000 + A1: 2002 Smoke Detectors Certificated Products XPA-OP-12034-APO 58000-500 Discovery 58000-600 Discovery 55000-215 Series 65 55000-216 Series 65 55000-217 Series 65 55000-218 Series 65 55000-219 Series 65 55000-220 Series 65 55000-315 Series 65 55000-316 Series 65 55000-317 Series 65 55000-500 XP95 55000-520 XP95 55000-600 XP95 234 Xpander addressable radio linked photoelectric smoke detector (XPA-WB-10022-APO mounting base) Notes: 1) The complete radio base/detector combination is available as Apollo Part No.: XPACB-12034-APO. 2) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells. 3) The radio link functionality is not included within the scope of approval. Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting base)2 Note: Meets the requirements of EN 54:Part 7 in modes 1, 2, 3, 4, 5 and in conventional mode. Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols that have been configured for the Discovery ionisation smoke detectors has been configured in accordance with manufacturer's instructions. Analogue addressable photoelectric smoke detector (45681-209 and 45681-210 mounting base)2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery optical smoke detectors in accordance with manufacturers instructions. Conventional ionisation smoke detector - Flashing LED/Reed switch (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional ionisation smoke detector - Flashing LED (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional ionisation smoke detector - Standard (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional integrating ionisation smoke detector - Flashing LED/Reed switch (45681200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional integrating ionisation smoke detector - Flashing LED (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional integrating ionisation smoke detector - Standard (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional optical smoke detector - Flashing LED/Reed switch (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional optical detector - Flashing LED (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional optical smoke detector - Standard (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting base) 2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery ionisation smoke detectors in accordance with manufacturers instructions . Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting base) 2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery ionisation smoke detectors in accordance with manufacturers instructions . Analogue addressable optical smoke detector (45681-209 and 45681-210 mounting base) 2 LPCB Ref. No. 010ac/01 010q/02 010q/03 010q/04 010q/05 010q/06 010q/07 010q/08 010q/09 010q/10 010q/11 010q/12 010q/16 010q/17 010q/18 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 55000-620 XP95 55000-560 XP95 55000-660 XP95 55000-640 XP95 IS 55000-540 XP95 IS Orbis Orbis IS LPCB Ref. No. Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery optical smoke detectors in accordance with manufacturers instructions. Analogue addressable optical smoke detector (45681-209 and 45681-210 mounting base) 2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery optical smoke detectors in accordance with manufacturers instructions. Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting base) 2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery ionisation smoke detectors in accordance with manufacturers instructions . Analogue addressable optical smoke detector (45681-209 and 45681-210 mounting base)2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery optical smoke detectors in accordance with manufacturers instructions. Analogue addressable intrinsically safe optical smoke detector (45681-215 mounting base) Certified with Apollo Series 90 and XP95 digital communications protocol Analogue addressable intrinsically safe ionisation smoke detector (45681-215 mounting base) Certified with Apollo Series 90 and XP95 digital communications protocol Optical smoke detectors with Apollo Approval Reference* 00007 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base) ORB-OP-12001-APO Orbis optical smoke detector with SensAlert, FasTest and DirtAlert ORB-OP-12003-APO Orbis optical smoke detector with Flashing LED, SensAlert, FasTest and DirtAlert OAX-OP-12004-APO Orbis optical smoke detector with SensAlert OPX-OP-12005-APO Orbis optical smoke detector with SensAlert and DirtAlert OEX-OP-12007-APO Orbis optical smoke detector with Flashing LED and SensAlert OIX-OP-12008-APO Orbis optical smoke detector with Flashing LED, SensAlert and DirtAlert OMX-OP-12009-APO Orbis optical smoke detector with SensAlert and DirtAlert OSX-OP-12011-APO Orbis optical smoke detector with Flashing LED and SensAlert OMX-OP-12013-APO Orbis optical smoke detector with Flashing LED, SensAlert and DirtAlert OAX-OP-12014-APO Orbis optical smoke detector with Flashing LED and SensAlert OEX-OP-12016-APO Orbis optical smoke detector with SensAlert OSX-OP-12017-APO Orbis optical smoke detector with SensAlert OPX-OP-12023-APO Orbis optical smoke detector with Flashing LED, SensAlert and DirtAlert OLX-OP-12025-APO Orbis optical smoke detector with SensAlert and FasTest Intrinsically safe optical smoke detectors with Apollo Approval Reference* 50007 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008-APO adapter base 010q/19 010q/20 010q/21 010q/22 010q/23 010s/01 010s/02 ORB-OP-52027-APO Orbis intrinsically safe optical smoke detector with SensAlert, FasTest and DirtAlert ORB-OP-52028-APO Orbis intrinsically safe optical smoke detector with Flashing LED, SensAlert, FasTest and DirtAlert Bases: 45681-200 Series 60 mounting base 45681-200 Series 60/65 Mounting Base 45681-201 Series 60 diode mounting base 45681-201 Series 60/65 Diode Mounting Base 45681-207 Series 60 intrinsically safe mounting base 45681-209 XP95/Discovery standard deep mounting base 45681-210 XP95 mounting base 45681-215 XP95 intrinsically safe mounting base 45681-245 Series 65 Relay mounting base 45681-246 Series 65 Auxiliary mounting base 45681-247 Series 65 EOL 12 Volt mounting base 45681-248 Series 65 EOL 24 Volt mounting base 45681-500 XPlorer standard mounting base 45681-501 XPlorer remote LED mounting base TimeSaver bases with Apollo Approval Reference* OB TimeSaver LX bases with Apollo Approval Reference* OL TimeSaver diode bases with Apollo Approval Reference* OD 20 Oct 2014 235 PART 1: SECTION 4.1 COMMERCIAL DETECTORS TimeSaver relay bases with Apollo Approval Reference* OR TimeSaver LX diode bases with Apollo Approval Reference* DX TimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking) ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207) ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201) XPA-WB-10022-APO Radio link mounting base** * The Apollo ‘Approval Reference Number’ identifies a group of detectors that all have the same physical construction, but have features enabled or disabled via their software, and/or regional marking variations. **Base manufactured by EMS Certificate No: 010h to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 & CEA 4021:2003 Certificate No: 010m to EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003 Certificate No: 010t to EN 54-7: 2000 & CEA 4021: 1999-06 Certificate No: 010ad to EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products XPA-OH-13032-APO 58000-700 Discovery 55000-885 Orbis Orbis IS Xpander addressable radio linked photoelectric multisensor smoke detector (XPA-WB10022-APO mounting base) Notes: 1) The complete radio base/detector combination is available as Apollo Part No.: XPACB-13032-APO. 2) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells. 3) The radio link functionality is not included within the scope of approval. Analogue addressable multisensor detector (45681-209 and 45681-210 mounting base) Note: Certificated at the following settings. Mode 1 - High sensitivity smoke detector with standard heat enhancement. Mode 2 - Smoke detection only. Mode 3 - Medium sensitivity smoke detector with standard heat enhancement. Mode 4 - Low sensitivity smoke detector with high heat enhancement. Mode 5 - Class A1 heat detector. Also Certificated in conventional alarm modes 1, 2, 3, 4 and 5. Certificated with Discovery XP95 and S90 digital communication protocols that have been configured for the Discovery multisensor detector in accordance with manufacturer's instructions. XP95 Analogue addressable multisensor detector (45681-209 and 45681-210 mounting base) Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols that have been configured for the Discovery multisensor detector in accordance with manufacturer's instructions. Multisensor smoke detectors with Apollo Approval Reference* 00008 for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base) ORB-OH-13001-APO Orbis multisensor smoke detector with SensAlert, FasTest and DirtAlert ORB-OH-13003-APO Orbis multisensor smoke detector with Flashing LED, SensAlert, FasTest and DirtAlert OAX-OH-13004-APO Orbis multisensor smoke detector with SensAlert OPX-OH-13005-APO Orbis multisensor smoke detector with SensAlert and DirtAlert OEX-OH-13007-APO Orbis multisensor smoke detector with Flashing LED and SensAlert OIX - OH-13008-APO Orbis multisensor smoke detector with Flashing LED, SensAlert and DirtAlert OMX-OH-13009-APO Orbis multisensor smoke detector with SensAlert and DirtAlert OSX-OH-13011-APO Orbis multisensor smoke detector with Flashing LED and SensAlert OMX-OH-13013-APO Orbis multisensor smoke detector with Flashing LED, SensAlert and DirtAlert OAX-OH-13014-APO Orbis multisensor smoke detector with Flashing LED and SensAlert OEX-OH-13016-APO Orbis multisensor smoke detector with SensAlert OSX-OH-13017-APO Orbis multisensor smoke detector with SensAlert OPX-OH-13023-APO Orbis multisensor smoke detector with Flashing LED, SensAlert and DirtAlert OLX-OH-13025-APO Orbis multisensor smoke detector with SensAlert and FasTest Intrinsically safe multisensor detectors with Apollo Approval Reference* 50008 (Approved for use with base styles OB (+ATEX marking) and ORB-MB-50008-APO adapter base) LPCB Ref. No. 010ad/01 010h/01 010m/01 010t/01 010t/02 ORB-OH-53027-APO Orbis intrinsically safe multisensor detector with SensAlert, 236 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. FasTest and DirtAlert ORB-OH-53028-APO Orbis intrinsically safe multisensor detector with Flashing LED, SensAlert, FasTest and DirtAlert Bases: 45681-209 XP95/Discovery standard deep mounting base 45681-210 XP95 mounting base TimeSaver bases with Apollo Approval Reference* OB TimeSaver LX bases with Apollo Approval Reference* OL TimeSaver diode bases with Apollo Approval Reference* OD TimeSaver relay bases with Apollo Approval Reference* OR TimeSaver LX diode bases with Apollo Approval Reference* DX TimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking) ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207) ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201) XPA-WB-10022-APO Radio link mounting base** * The Apollo ‘Approval Reference Number’ identifies a group of detectors that all have the same physical construction, but have features enabled or disabled via their software, and/or regional marking variations. **Base manufactured by EMS Certificate No: 010an to EN 54-10: 2002 + A1:2005 Flame Detectors Certificated Products 55000-022 55000-023 55000-024 55000-025 55000-019 55000-060 55000-061 55000-062 55000-063 55000-064 55000-065 55000-282 55000-020 55000-021 55000-280 55000-295 20 Oct 2014 XP95 intelligentflame detector (45681-209 and 45681-210) Note: Meets EN 54-10: 2002 at Class 1 and Class 3 XP95 intelligent 2 flame detectorand 45681-210) Note: Meets EN 54-10: 2002 at Class 1 and Class 3 XP95 intelligent 3 flame detectorand 45681-210) Note: Meets EN 54-10: 2002 at Class 1 and Class 3 S65 conventional UV flame detector (45681-200 and 45681-201) Note: Meets EN 54-10: 2002 at Class 1 and Class 3 Conventional IR 3 Flame Detector (29600-203) Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR² Flame Detector (29600-203) Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR² (Exd) Flameproof Flame Detector (29600-203) Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR 3 (Exd) Flameproof Flame Detector (29600-203) Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR 3 Intrinsically Safe Flame Detector (29600-203) Note: Meets EN 54-10: 2002 at Class 1 only Conventional UV/IR 2 Flame Detector (29600-203) Note: Meets EN 54-10: 2002 at Class 1 only Conventional UV/IR 2 (Exd) Flameproof Flame Detector (29600-203) Note: Meets EN 54-10: 2002 at Class 1 only Analogue Addressable IR 3 Intrinsically Safe Flame Detector (29600-203) Note: Meets EN 54-10: 2002 at Class 1 only Analogue Addressable IR 3 Flame Detector (29600-203) Note: Meets EN 54-10:2002 at Class 1 only Analogue Addressable IR 3 (Exd) Flameproof Flame Detector (29600-203) Note: Meets EN 54-10:2002 at Class 1 only Analogue Addressable IR 2 Flame Detector (29600-203) Note: Meets EN 54-10:2002 at Class 1 only Analogue Addressable IR 2 (Exd) Flameproof Flame Detector (29600-203) LPCB Ref. No. 010an/01 010an/02 010an/03 010an/04 010an/05 010an/06 010an/07 010an/08 010an/09 010an/10 010an/11 010an/12 010an/13 010an/14 010an/15 010an/16 237 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. Note: Meets EN 54-10:2002 at Class 1 only Bases 45681-200 45681-201 45681-209 45681-210 29600-203 Mounting Base Mounting Base with Diode Deep Base Mounting Base Adjustable Mounting Base Ancillaries 29600-203 Mounting Bracket Certificate No: 010aq to LPS 1274: 2005, EN 54-5: 2000 + A1: 2002 and LPS 1265: 2004 Multi-Sensor/Multi-Criteria Detectors Certificated Products 58000-305 LPCB Ref. No. 010aq/01 Analogue addressable CO/heat multisensor detector (45681-210, standard intelligent mounting base) Notes: 1. Approved with the following mode configurations:Mode 1 30 ppm with high thermal enhancement (most sensitive) Mode 2 33 ppm with CO only Mode 3 40 ppm with low thermal enhancement (nominal sensitivity) 45 ppm with high thermal enhancement (least sensitive) Mode 4 Mode 5 heat onlyA1R 2. Mode 1 , 3, and 4 are approved to LPS1274:2005 and EN 54-5:2000 + A1: 2002 3. Mode 2 is approved to LPS 1265:2004 4. Mode 5 is approved to EN 54-5:2000 + A1:2002 Conditions of approval include; a) b) c) Base: 45681-210 The 58000-305 should only be installed in accordance with the manufacturer’s recommendations. The 58000-305 should not be set only as a carbon monoxide fire detector where there is a specific risk of rapid burning/flaming fires. Refer to technical publication PP2382 for limitations on the use of carbon monoxide fire detection. Standard intelligent mounting base Certificate No: 010at to EN 54-17: 2005 Isolating base Certificated Products 45681-505 Negative switching isolating base LPCB Ref. No. 010at/01 Certificate No: 010ar to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products 55000-465 55000-475 Analogue addressable Classheat detector (45681-200 , 45681-213 and 45681-505 mounting bases) Analogue addressable Classheat detector (45681-200 , 45681-213 and 45681-505 mounting bases) LPCB Ref. No. 010ar/01 010ar/02 Bases: 238 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS 45681-200 Mounting base 45681-213 Common mounting base 45681-505 Negative switching isolating base Certificate No: 010as to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products 55000-665 Analogue addressable optical smoke (45681-200 , 45681-213 and 45681-505 mounting bases) LPCB Ref. No. 010as/01 Bases: 45681-200 Mounting base 45681-213 Common mounting base 45681-505 Negative switching isolating base Argus Security S.r.l. Via del Canneto 14, Valle delle Noghere, 34015 Muggia, Trieste, Italy Tel: +39 (0) 402821110 • Fax: +39 (0) 402823483 E-mail: [email protected] • Website: www.argussecurity.it Certificate No: 928a to EN 54-5: 2000 + A1: 2002 and EN 54 -17: 2005 Certificate No: 928d to EN 54-5: 2000 + A1: 2002 Point Heat Detectors Certificated Products V350 A3500 LV350 S3500 Bases VB100 UB100 VB100S UB100S VDBS100 DBS100 VDBS100S DBS100S UBR100 DBSR100 UBDR100 DBSRD100 LAB100 Analogue addressable Class P heat detector with short circuit isolator (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B Addressable Class P heat detector with short-circuit isolator (LAB100 base) Note: 1. Meets the requirements of EN 54-5 for Class A1R, Class B and Class BS Vega-Lite analogue addressable Class P, heat detector (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B. Conventional Class P heat detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 928a/01 928a/02 928d/01 928d/02 Vega adaptor mounting base (with link resistor) Universal adaptor mounting base Vega adaptor base with shorting clip Universal adaptor base with shorting clip Vega deep adaptor base Deep adaptor base Vega deep adaptor base with shorting clip Deep adaptor base with shorting clip Universal adaptor base with resistor Deep adaptor base with resistor Universal adaptor base with resistor and Schottky diode Deep adaptor base with resistor and Schottky diode Standard mounting base Certificate No: 928b to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 928e to EN 54-7: 2000 + A1: 2002 + A2: 2006 20 Oct 2014 239 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Point Smoke Detectors Certificated Products LPCB Ref. No. 928b/01 V100 Analogue addressable photoelectric smoke detector with short circuit isolator (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low A1000 Addressable photoelectric smoke detector with short-circuit isolator (LAB100 base) Notes: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low 928b/02 LV100 Vega-Lite analogue addressable optical smoke detector (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low 928e/01 S1000 Conventional photo smoke detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100) 928e/02 Bases VB100 UB100 VB100S UB100S VDBS100 DBS100 VDBS100S DBS100S UBR100 DBSR100 UBDR100 DBSRD100 LAB100 Vega adaptor mounting base (with link resistor) Universal adaptor mounting base Vega adaptor base with shorting clip Universal adaptor base with shorting clip Vega deep adaptor base Deep adaptor base Vega deep adaptor base with shorting clip Deep adaptor base with shorting clip Universal adaptor base with resistor Deep adaptor base with resistor Universal adaptor base with resistor and Schottky diode Deep adaptor base with resistor and Schottky diode Standard mounting base Certificate No: 928c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA 4021: 2003 Certificate No: 928f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Multisensor Detectors Certificated Products V200 240 Analogue addressable Class P heat and photoelectric smoke multi sensor detector with short circuit isolator (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Notes 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: LPCB Ref. No. 928c/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Addressable multi-criteria detector with short-circuit isolator (LAB100 base) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Vega-Lite analogue addressable photo thermal multisensor (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Notes 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low A2000 LV200 Bases VB100 UB100 VB100S UB100S VDBS100 DBS100 VDBS100S DBS100S LAB100 LPCB Ref. No. 928c/02 928f/01 Vega adaptor mounting base (with link resistor) Vega universal mounting base Vega adaptor base with shorting clip Universal adaptor base with shorting clip Vega deep adaptor base Deep adaptor base Vega deep adaptor base with shorting clip Deep adaptor base with shorting clip Standard mounting base Certificate No: 928j to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008 Heat Detectors Certificated Products SG350 20 Oct 2014 Wireless heat detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1R 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928j/01 241 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Bases WAB100 Wireless Adaptor Base Certificate No: 928k to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008 Smoke Detectors Certificated Products SG100 Bases WAB100 Wireless optical smoke detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-7 in the normal sensitivity setting 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928k/01 Wireless Adaptor Base Certificate No: 928m to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003 Multi-Criteria Detectors Certificated Products SG200 Bases WAB100 Wireless multi-criteria detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1 2. Meets the requirements of EN 54-7 in the normal sensitivity settings 3. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928m/01 Wireless Adaptor Base Argus-Spectrum 65 Serdobolskaya St, St. Petersburg 197342, Russian Federation Tel: +7 812 7037500 • Fax: +7 812 7037501 E-mail: [email protected] • Website: www.argus-spectr.ru Certificate No: 928k-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008 Smoke Detectors Certificated Products SG100 Wireless optical smoke detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-7 in the normal sensitivity setting 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928k/01 Bases: WAB100 - Wireless Adaptor Base Certificate No: 928a-(cl-2) to 54-5: 2000 + A1: 2002 and EN 54 -17: 2005 Certificate No: 928d-(cl-2) to EN 54-5: 2000 + A1: 2002 Certificate No: 603d to EN 54-5: 2000 + A1: 2002 Certificate No: 928j-(cl-3) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008 242 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Point Heat Detectors Certificated Products S3500 Conventional Class P heat detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable Class P heat detector with short circuit isolator (VB100 and UB100 bases) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B. V350 LPCB Ref. No. 603d/01 928a/01 LV350 Vega-Lite analogue addressable Class P, temperature detector (VB100 and UB100 bases) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B. 928d/01 SG350 Wireless heat detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1R 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery 928j/01 Bases: BS100 BSD100 VB100 UB100 DBS100 UBR100 DBSR100 UBDR100 DBSRD100 WAB100 Standard base Schottky Diode base Vega adaptor mounting base (with link resistor) Universal adaptor base Deep adaptor base Universal adaptor base with resistor Deep adaptor base with resistor Universal adaptor base with resistor and Schottky diode Deep adaptor base with resistor and Schottky diode Wireless Adaptor Base Certificate No: 928b-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005 Certificate No: 928e-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 603c to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detector Certificated Products S1000 Conventional photo smoke detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100) Analogue addressable photoelectric smoke detector with short circuit isolator (VB100 and UB100 bases) V100 Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 Low Vega-Lite analogue addressable optical smoke detector (VB100 and UB100 bases) LV100 LPCB Ref. No. 603c/01 928b/01 928e/01 Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 Low Bases VB100 UB100 UB100 DBS100 UBR100 DBSR100 UBDR100 DBSRD100 Vega adaptor mounting base (with link resistor) Vega universal mounting base Universal adaptor base Deep adaptor base Universal adaptor base with resistor Deep adaptor base with resistor Universal adaptor base with resistor and Schottky diode Deep adaptor base with resistor and Schottky diode 20 Oct 2014 243 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 928c-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA4021: 2003 Certificate No: 928f-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Multi-sensor Detectors Certificated Products V200 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (VB100 and UB100 bases) Notes 1. 2. 3. LV200 LPCB Ref. No. 928c/01 Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Vega-Lite analogue addressable photo thermal multisensor (VB100 and UB100 bases) Notes 1. 2. 3. 928f/01 Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Bases VB100 Vega adaptor mounting base (with link resistor) UB100 Vega universal mounting base Certificate No: 928m-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003 Multi-Criteria Detectors Certificated Products SG200 Wireless multi-criteria detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1 2. Meets the requirements of EN 54-7 in the normal sensitivity setting 3. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928m/01 Bases: WAB100 Wireless Adaptor Base 244 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS ATEIS Middle East FZCO LIU 11 Dubai Silicon Oasis, Post Box 293640, Dubai, United Arab Emirates Tel: +971 4 3262730 • Fax: +971 4 3262731 E-mail: [email protected] • Website: www.ateis.ae Certificate No: 928a-(cl-7) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 1154a to EN 54-5: 2000 + A1: 2002 & EN 54-17:2005 Certificate No: 1154d to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products VELOX 40930 VELOX LV350 X350 VELOX V350 Bases VELOX VB100 UB100 VELOX VB100S UB100S VELOX VDBS100 DBS100 VELOX VDBS100S DBS100S UBR100 DBSR100 UBDR100 DBSRD100 40900 40900-S 40900-DP 40900-DPS 3900 3900-DP 3900-R 3900-DPR 3900-RD 3900-DPRD Analogue Addressable Class P Heat Detector with Short Circuit Isolator (40900, 40900S, 40900-DP and 40900-DPS Bases)Note:Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable Class P heat detector lite (40900, 40900-S, 40900-DP, 40900DPS bases) Note: Meets the requirements of EN 54-5 for Class A1R and Class B Conventional Class P heat detector (3900, 3900-DP, 3900-R, 3900-DPR, 3900-RD and 3900-DPRD bases) Note: Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable Class P heat detector with short circuit isolator (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 1154a/01 1154d/01 1154d/02 928a/01 Velox adaptor base Universal adaptor base Velox adaptor base with shorting clip Universal adaptor base with shorting clip Velox deep adaptor base Deep adaptor base Velox deep adaptor base with shorting clip Deep adaptor base with shorting clip Universal adaptor base with resistor Deep adaptor base with resistor Universal adaptor base with resistor and Schottky diode Deep adaptor base with resistor and Schottky diode Velox adaptor base Velox adaptor base with short clip Velox deep adaptor base Velox deep adaptor base with short clip Conventional detector adaptor base Conventional detector deep adaptor base Conventional detector adaptor base with resister Conventional detector deep adaptor base with resistor Conventional detector adaptor base with resistor and Schottky diode Conventional detector deep adaptor base with resister and Schottky diode Certificate No: 928b-(cl-7) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 928k-(cl-4) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008 Certificate No: 1154e to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 1154b to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005 Smoke Detectors Certificated Products VELOX 40910 20 Oct 2014 Analogue Addressable Photoelectric Smoke Detector with Short Circuit Isolator (40900, 40900-S, 40900-DP and 40900-DPS Bases) Note: Meets the requirements of EN 54-7 at the following sensitivity settings: LPCB Ref. No. 1154b/01 245 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable photoelectric smoke detector lite (40900, 40900-S, 40900-DP and 40900-DPS bases) Note: Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Conventional photoelectric smoke detector (3900, 3900-DP, 3900-R, 3900-DPR, 3900RD and 3900-DPRD bases) Analogue addressable photoelectric smoke detector with short circuit isolator (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Wireless optical smoke detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1R 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery VELOX LV100 X100 VELOX V100 VELOX WL100 Bases VELOX VB100 UB100 VELOX VB100S UB100S VELOX VDBS100 DBS100 VELOX VDBS100S DBS100S WAB100 40900 40900-S 40900-DP 40900-DPS 3900 3900-DP 3900-R 3900-DPR 3900-RD 3900-DPRD LPCB Ref. No. 1154e/01 1154e/02 928b/01 928k/01 Velox adaptor base Universal adaptor base Velox adaptor base with shorting clip Universal adaptor base with shorting clip Velox deep adaptor base Deep adaptor base Velox deep adaptor base with shorting clip Deep adaptor base with shorting clip Wireless Adaptor Base Velox adaptor base Velox adaptor base with short clip Velox deep adaptor base Velox deep adaptor base with short clip Conventional detector adaptor base Conventional detector deep adaptor base Conventional detector adaptor base with resister Conventional detector deep adaptor base with resistor Conventional detector adaptor base with resistor and Schottky diode Conventional detector deep adaptor base with resister and Schottky diode Certificate No: 928c-(cl-7) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003 Certificate No: 928m-(cl-4) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003 Certificate No: 1154f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003 Certificate No: 1154c to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005 & CEA 4021: 2003 Multi-Criteria Detectors Certificated Products VELOX 40920 Analogue Addressable Class P Heat and Photoelectric Smoke Multi-sensor Detector with Short Circuit Isolator (40900, 40900-S, 40900-DP and 40900-DPS Bases) LPCB Ref. No. 1154c/01 Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat 246 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products VELOX LV200 VELOX V200 VELOX WL200 LPCB Ref. No. response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable Class P heat and photoelectric smoke multi-sensor detector lite (40900, 40900-S, 40900-DP and 40900-DPS bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Wireless multi-criteria detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1 2. Meets the requirements of EN 54-7 in the normal sensitivity setting 3. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery Bases VELOX VB100 UB100 VELOX VB100S UB100S VELOX VDBS100 DBS100 VELOX VDBS100S DBS100S WAB100 Velox adaptor base Universal adaptor base Velox adaptor base with shorting clip Universal adaptor base with shorting clip Velox deep adaptor base Deep adaptor base Velox deep adaptor base with shorting clip Deep adaptor base with shorting clip Wireless Adaptor Base 40900 40900-S 40900-DP 40900-DPS Velox adaptor base Velox adaptor base with short clip Velox deep adaptor base Velox deep adaptor base with short clip 20 Oct 2014 1154f/01 928c/01 928m/01 247 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 928j-(cl-4) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008 Point Heat Detectors Certificated Products VELOX WL350 Bases: WAB100 Wireless heat detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1R 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928j/01 Wireless Adaptor Base Autronica Fire & Security AS Postboks 5620 NO-7483, Trondheim, Norway Tel: +47 73582500 • Fax: +47 73582501 E-mail: [email protected] • Website: www.autronicafire.no Certificate No: 1130a to EN54-10: 2002 + A1: 2005 & EN54-17: 2005 Certificate No: 1130b to EN54-10: 2002 + A1: 2005 Flame Detectors Certificated Products BG-201 BG-21 Anaologue addressable IR flame detector (interactive) Note: Meets EN54-10: 2002 at Class 1, Class 2 & Class 3 Conventional IR flame detector Note: Meets EN54-10: 2002 at Class 1 & Class 3 LPCB Ref. No. 1130a/01 1130b/01 Bardic by Honeywell (Novar Systems Ltd) 140 Waterside Road, Hamilton Industrial Estate, Leicester LE5 1TN, United Kingdom Tel: +44 (0) 116 246 2212 • Fax: +44 (0) 116 246 2210 Website: www.bardic.co.uk Certificate No: 199n to EN 54-5: 2000 Heat Detectors Certificated Products ZF03 class A2S ZF04 class BS ZF05 class A1R Conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Conventional rate of rise heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) LPCB Ref. No. 199n/10 199n/11 199n/12 Bases: 2020B Standard base 2020DB Deep base 2020BSD Standard base with schottky diode 2020DBSD Deep base with schottky diode Certificate No: 199m to EN 54-7: 2000 248 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Photoelectric Detectors Certificated Products ZF01 Conventional photoelectric detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) LPCB Ref. No. 199m/05 Bases: 2020B Standard base 2020DB Deep base 2020BSD Standard base with schottky diode 2020DBSD Deep base with schottky diode Certificate No: 199p to EN 54-5: 2000, EN 54-7: 2000 & CEA 4021 1999 Multi-criteria Detectors Certificated Products ZF02 Conventional photo thermal detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) LPCB Ref. No. 199p/04 Bases: 2020B Standard base 2020DB Deep base 2020BSD Standard base with schottky diode 2020DBSD Deep base with schottky diode Beijing Leader Huaxin Electronics Co. Ltd No. 17 Rongjing Eastern Road, Economy & Technology Developed Area, Beijing 100176, China Tel: +86 10 67876681 • Fax: +86 10 67863972 E-mail: [email protected] • Website: www.beijingleader.com.cn Certificate No: 987a to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificated Products JTY-GM-LD3000EN/A Analogue addressable photoelectric smoke detector (LD10EN base) LPCB Ref. No. 987a/01 Bases: LD10EN mounting base Beijing VSAIL Fire Protection Equipment Co Ltd No. 401, Unit A, Building 32,, No. 99 14th Kechuang Street, BDA, Beijing 100176, China Tel: +86 (0) 10-56691196 • Fax: +86 (0) 10-56691100 Website: http://www.vsail.com.cn Certificate No: 1174b to EN 54-5:2000 + A1: 2002 Heat detector Certificated Products VC-6633 Conventional heat detector Note: Meets the requirements of EN 54-5 2000 at class A2R LPCB Ref. No. 1174b/01 Base VB-6611 Certificate No: 1174a to EN54:7:2000 + A1: 2002 + A2: 2006 20 Oct 2014 249 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Smoke Detectors Certificated Products VC-6623 LPCB Ref. No. 1174a/01 Conventional Optical Smoke Detector (VB-6611 base) Note: Meets the requirements of EN 54-7: 2000 at default sensitivity setting only. Base VB-6611 Bristol Fire Ltd The Colin Saunders Innovation Centre, Mewburn Road, Banbury, Oxfordshire OX16 9PA, United Kingdom Tel: +44 1295 817623 E-mail: [email protected] • Website: www.bristol-fire.com Certificate No: 506b-(cl-2) to EN 54-7 : 2000 + A1: 2002 + A2: 2006, EN 54-5 : 2000 + A1 : 2002 and CEA 4021: 2003 Point Smoke Detectors Certificated Products BF-SH-0115-2 BF-SH-0115-3 BF-SH-0115-4 (2 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) (3 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) (4 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) LPCB Ref. No. 506b/01 506b/02 506b/03 Bases AHMB-031 mounting base Certificate No: 506c-(cl-2) to EN 54-5: 2000 + A1 : 2002 Heat Detectors Certificated Products BF-H-0116-2 BF-H-0116-3 BF-H-0116-4 (2 Wire) Conventional Class A2 rate of rise and fixed temperature Heat detector (AHMB-031 Base) (3 Wire) Conventional Class A2 rate of rise and fixed temperature Heat detector (AHMB-031 Base) (4 Wire) Conventional Class A2 rate of rise and fixed temperature Heat detector (AHMB-031 Base) LPCB Ref. No. 506c/01 506c/02 506c/03 Bases AHMB-031 mounting base Certificate No: 506a-(cl-3) to EN 54-7 : 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products BF-S-0111-2 BF-S-0111-3 BF-S-0111-4 (2 wire) Conventional Photoelectric smoke detector (AHMB-031-L Base) (3 wire) Conventional Photoelectric smoke detector (AHMB-031-L Base) (4 wire) Conventional Photoelectric smoke detector (AHMB-031-L Base) LPCB Ref. No. 506a/02 506a/03 506a/04 Bases AHMB-L Mounting base AHMB-031 Mounting base 250 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Ceasefire Industries Ltd "Doli Chambers", Flat 602 6th Floor behind strand cinema, Colaba, Mumbai-400 005, India Tel: + 91-(0) 22-22854677 • Fax: +91-(0) 22-66349069 E-mail: [email protected] • Website: www.ceasefire.in Certificate No: 117g-(cl-1) to EN54-5:2000 Point Heat Detectors Certificated Products DFJ-AE3 Class A1S conventional fixed temperature heat detector (YBN-R/6 base) Class CR conventional rate of rise high temperature heat detector (YBN-R/6 base) Analogue addressable Class P heat detector (YBN-R/3 and YBO-R/SCI bases) Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol. DCD-CE3 ACB-E LPCB Ref. No. 117g/02 117g/06 117g/09 Bases YBN-R/3 base YBN-R/6 standard base YBO-R/SCI isolator base Certificate No: 358c-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products ALK-E (WHT) Analogue addressable optical smoke detector (White) (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Conventional optical smoke detector (White) (YBN-R/6) SLV-E3 (WHT) Bases YBN-R/3 YBN-R/6 YBO-R/SCI YBO-BS YBO-BSB LPCB Ref. No. 358c/03 358c/05 base standard base isolator base base sounder base sounder and beacon Chubb Fire Ltd Chubb House, Staines Road West, Sunbury on Thames TW16 7AR, United Kingdom Tel: +44 (0)1932 785588 • Fax: +44 (0)1932 777222 E-mail: [email protected] • Website: www.chubb.co.uk Certificate No: 118h to EN 54-7: 2000 Point Smoke Detectors Certificated Products Resonance High Sensitivity Laser Analogue addressable photoelectric laser smoke detector (B501, B501DG and B5241EFT & B524IEFT-1 bases) Note: meets the requirements of EN 54-7: 2000 at sensitivities 7 to 9 inclusive LPCB Ref. No. 118h/01 Bases: B501 Analogue sensor base B501DG Analogue sensor deep base B524IEFT Analogue sensor isolator base 20 Oct 2014 251 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Consilium Marine and Safety AB Salsmästaregatan 21 Box 8763, Gothenburg SE402 76, Sweden Tel: +46 31 710 77 64 • Fax: +46 31 710 78 00 E-mail: [email protected] • Website: www.consilium.se Certificate No: 041k-(cl-1) to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003 Photoelectric smoke and heat detectors Certificated Products EV-PP Analogue addressable combined photoelectric smoke and class A1 heat sensor LPCB Ref. No. 041k/01 Bases UB-2 Universal base UB-6 Universal base Context Plus Ltd Export House, 175 Mauldeth Road, Fallowfield, Manchester M14 6SG, United Kingdom Tel: +44 (0)161 257 2541 • Fax: +44 (0)161 225 8817 E-mail: [email protected] • Website: www.xportsales.com Certificate No: 010u-(cl-2) to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products 55000-465IMC Analogue addressable Class A2S heat detector 45681-213IMC and 45681-505IMC bases) Analogue addressable Class CS heat detector 45681-213IMC and 45681-505IMC bases) 55000-475IMC Bases 45681-200IMC 45681-213IMC 45681-505IMC LPCB Ref. No. 010u/04 010u/05 Mounting base Common mounting base Negative switching isolating base Certificate No: 010v-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products 55000-665IMC Bases 45681-200IMC 45681-213IMC 45681-505IMC 252 Analogue addressable optical smoke 45681-213IMC and 45681-505IMC bases) LPCB Ref. No. 010v/02 Mounting base Common mounting base Negative switching isolating base 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Control Equipment Limited Hillcrest Business Park, Dudley, West Midlands DY2 9AP, United Kingdom Tel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972 E-mail: [email protected] • Website: www.controlequipment.com Certificate No: 681b-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA4021: 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products FC460PC FC460PH FIRE CLASS digital addressable photoelectric smoke, Class P heat and Carbon Monoxide detector (4B, 4B-I, and 5B bases) Notes: 1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector -RESIL Resilient optical smoke and A2S heat multi-criteria detector - Heat detector at Class A1R - HPO Heat enhanced optical smoke detector at Normal sensitivity 2. The Carbon Monoxide toxic gas/CCO modes are not approved FIRE CLASS digital addressable photoelectric smoke and Class P heat detector (4B, 4BI, and 5B bases) Note: Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic - HPO Heat enhanced optical smoke at High, Normal and Low sensitivity - FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using FastLogic. LPCB Ref. No. 681b/03 681b/05 Bases 4B, 4” universal mounting base 4B-I, 4” isolator base 5B, 5” universal mounting base Certificate No: 681c-(cl-2) to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products FC460H FIRE CLASS digital addressable Class P heat detector (4B, 4B-I and 5B bases) Note: Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - Heat detector at Class CR LPCB Ref. No. 681c/10 Bases 4B, 4” universal mounting base 4B-I, 4” isolator base 5B, 5” universal mounting base Certificate No: 681d-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products FC460P 20 Oct 2014 FIRE CLASS digital addressable photoelectric smoke detector (4B, 4B-I and 5B bases) Note: 1. Approved with the following mode configurations:- LPCB Ref. No. 681d/07 253 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. - OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic Bases 4B, 4” universal mounting base 4B-I, 4” isolator base 5B, 5” universal mounting base Cooper Safety Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom Tel: +44 (0)1302 321541 • Fax: +44 (0)1302 303220 Certificate No: 685j-(cl-1) to EN 54-7:2000 + A1:2002 + A2:2006 & EN 54-17:2005 Certificate No: 685j-(cl-2) to EN 54-7:2000 + A1:2002 + A2:2006 & EN 54-17:2005 Certificate No: 685h-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 685h-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products CPD321 CPDB321 FXN533 MPD821 CAP320 CAPB320 COPP420 FXN723 MAP820 Bases MDB800 MCBD FXCBD NDFXN520 FXN520 CDB300 CDBB300 CCBD MAB800 CABB300 FXN720 MABD CABD FXABD CAB300 COPA800 254 Conventional photoelectric smoke detector CDBB300, MCBD, CCBD and NDFXN520 bases) Conventional photoelectric smoke detector FXCBD, CCBD and NDFXN520 bases) Conventional photoelectric smoke detector FXCBD and NDFXN520 bases) Conventional photoelectric smoke detector MCBD and NDFXN520 bases) Intelligent analogue addressable photoelectric smoke detector MABD, FXABD and CABD bases) Intelligent analogue addressable photoelectric smoke detector MABD, FXABD and CABD bases) Intelligent analogue addressable photoelectric smoke detector MABD, FXABD and CABD bases) Intelligent analogue addressable photoelectric smoke detector MABD, FXABD and CABD bases) Intelligent analogue addressable photoelectric smoke detector MABD, FXABD and CABD bases) LPCB Ref. No. 685h/01 685h/01 685h/01 685h/01 685j/01 685j/01 685j/01 685j/01 685j/01 Single contact standard conventional mounting base (Zener diode) Double contact standard conventional mounting base (Zener diode) Double contact conventional mounting base (Schottky diode) Single contact conventional mounting base (without diode) Single contact conventional mounting base (Schottky diode) Single contact standard conventional mounting base (Zener diode) Single contact conventional mounting base (Schottky diode) Double contact conventional mounting base (Schottky diode) Single contact standard analogue addressable mounting base Single contact standard analogue addressable mounting base Single contact standard analogue addressable mounting base Double contact standard analogue addressable mounting base Double contact standard analogue addressable mounting base Double contact standard analogue addressable mounting base Single contact standard analogue addressable mounting base Single contact standard analogue addressable mounting base 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 685k-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA4021: July 2003(en) Certificate No: 685k-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA4021: July 2003(en) Certificate No: 685g-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Certificate No: 685g-(cl-2) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Multi-criteria Detectors Certificated Products CPT341 CPTB341 FXN632 MPT951 CXN633 FXN922 MPT922 CAPT340 CAPTB340 20 Oct 2014 Conventional photo/thermal multisensor and Class A2S heat detector CDBB300. MCBD, CCBD and NDFXN520 bases) Conventional photo/thermal multisensor and Class A2S heat detector CCBD and NDFXN520 bases) Conventional photo/thermal multisensor and Class A2S heat detector (FXN520, FXCBD and NDFXN520 bases) Conventional photo/thermal multisensor and Class A2S heat detector MCBD and NDFXN520 bases) Conventional photo/thermal multisensor and Class P heat detector CDBB300, FXCBD and CCBD bases) Notes: 1. Meets the requirements of EN 54-7:2000 in the following modes: Mode 1 - Thermally enhanced optical smoke detector Smoke sensitivity 0.15dB/m. Mode 2 - Optical smoke detector. Smoke sensitivity 0.1dB/m. 2. Meets the requirements of EN 54-5:2000 in the following modes: Mode 3 - Heat detector Class A1R Mode 4 - Heat detector Class BS Mode 5 - Heat detector Class CS Conventional photo/thermal multisensor and Class P heat detector CDBB300, FXCBD, CCBD) Notes: 1. Meets the requirements of EN 54-7:2000 in the following modes: Mode 1 - Thermally enhanced optical smoke detector Smoke sensitivity 0.15dB/m. Mode 2 - Optical smoke detector. Smoke sensitivity 0.1dB/m. 2. Meets the requirements of EN 54-5:2000 in the following modes: Mode 3 - Heat detector Class A1R Mode 4 - Heat detector Class BS Mode 5 - Heat detector Class CS LPCB Ref. No. 685g/01 685g/01 685g/01 685g/01 685g/02 685g/02 Conventional photo/thermal multisensor and Class P heat detector FXCBD, CCBD) Notes: 1. Meets the requirements of EN 54-7:2000 in the following modes: Mode 1 - Thermally enhanced optical smoke detector Smoke sensitivity 0.15dB/m. Mode 2 - Optical smoke detector. Smoke sensitivity 0.1dB/m. 2. Meets the requirements of EN 54-5:2000 in the following modes: Mode 3 - Heat detector Class A1R Mode 4 - Heat detector Class BS Mode 5 - Heat detector Class CS Intelligent analogue addressable Class A2S multisensor opto/heat detector MABD, FXABD and CABD bases) Notes: 1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S) 685g/02 Intelligent analogue addressable Class A2S multisensor opto/heat detector MABD, FXABD and CABD bases) 685k/01 685k/01 255 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. Notes: 1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S) COPOH450 Intelligent analogue addressable Class A2S multisensor opto/heat detector MABD, FXABD and CABD bases) Notes: 1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S) 685k/01 FXN722 Intelligent analogue addressable Class A2S multisensor opto/heat detector MABD, FXABD and CABD bases) Notes: 1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S) 685k/01 MAOH850 Intelligent analogue addressable Class A2S multisensor opto/heat detector MABD, FXABD and CABD bases) Notes: 1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S) 685k/01 Bases MDB800 MCBD NDFXN520 FXN520 FXCBD CDBB300 CCBD CDB300 MAB800 CABB300 FXN720 MABD CABD FXABD CAB300 COPA800 CABD Single contact standard conventional mounting base (Zener diode) Double contact standard conventional mounting base (Zener diode) Single contact conventional mounting base (without diode) Single contact conventional mounting base (Schottky diode) Double contact conventional mounting base (Schottky diode) Single contact conventional mounting base (Schottky diode) Double contact conventional mounting base (Schottky diode) Single contact standard conventional mounting base (Zener diode) Single contact standard analogue addressable mounting base Single contact standard analogue addressable mounting base Single contact standard analogue addressable mounting base Double contact standard analogue addressable mounting base Double contact standard analogue addressable mounting base Double contact standard analogue addressable mounting base Single contact standard analogue addressable mounting base Single contact standard analogue addressable mounting base Double contact standard analogue addressable mounting base Certificate No: 685m-(cl-1) to EN 54-5: 2000+A1:2002 & EN 54-17: 2005 Certificate No: 685m-(cl-2) to EN 54-5: 2000+A1:2002 & EN 54-17: 2005 Heat Detectors Certificated Products CAH330 CAHB330 256 Intelligent analogue addressable Class P heat detector MABD, FXABD and CABD bases) Notes: 1) Meets the requirements of EN 54-5 at classes A1R, BS and CS Intelligent analogue addressable Class P heat detector MABD, FXABD and CABD bases) LPCB Ref. No. 685m/01 685m/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products Notes: 1) Meets the requirements of EN 54-5 at classes A1R, BS and CS Intelligent analogue addressable Class P heat detector MABD, FXABD and CABD bases) Notes: 1) Meets the requirements of EN 54-5 at classes A1R, BS and CS Intelligent analogue addressable Class P heat detector MABD, FXABD and CABD bases) Notes: 1) Meets the requirements of EN 54-5 at classes A1R, BS and CS Intelligent analogue addressable Class P heat detector MABD, FXABD and CABD bases) Notes: 1) Meets the requirements of EN 54-5 at classes A1R, BS and CS COPH430 FXN725 MAH830 Bases MAB800 CABB300 FXN720 CAB300 COPA800 MABD FXABD CABD CABB300 LPCB Ref. No. 685m/01 685m/01 685m/01 Standard analogue addressable mounting base Standard analogue addressable mounting base Standard analogue addressable mounting base Standard analogue addressable mounting base Standard analogue addressable mounting base Double contact standard analogue addressable mounting base Double contact standard analogue addressable mounting base Double contact standard analogue addressable mounting base Single contact standard analogue addressable mounting base Certificate No: 685a-(cl-1) to EN 54-5: 2000 + A1: 2002 Certificate No: 685a-(cl-2) to EN 54-5: 2000 + A1: 2002 Point Heat Detectors Certificated Products CFR330 CFRB330 FXN525 MFR830 CMT360 CMTB360 FXN524 MMT860 CHT390 CHTB390 FXN526 MHT890 Bases MDB800 MCBD NDFXN520 FXN520 FXCBD CDB300 CDBB300 CCBD Conventional Class A2R heat detector CDBB300. MCBD, CCBD and NDFXN520 bases) Conventional Class A2R heat detector CCBD and NDFXN520 bases) Conventional Class A2R heat detector FXCBD and NDFXN520 bases) Conventional Class A2R heat detector MCBD and NDFXN520 bases) Conventional Class BS heat detector CDBB300, MCBD, CCBD, NDFXN520 bases) Conventional Class BS heat detector CCBD and NDFXN520 bases) Conventional Class BS heat detector FXCBD, NDFXN520 bases) Conventional Class BS heat detector MCBD and NDFXN520 bases) Conventional Class CS heat detector CDBB300, MCBD, CCBD and NDFXN520 bases) Conventional Class CS heat detector CCBD, NDFXN520 bases) Conventional Class CS heat detector FXCBD, NDFXN520 bases) Conventional Class CS heat detector MCBD and NDFXN520 bases) LPCB Ref. No. 685a/01 685a/01 685a/01 685a/01 685a/02 685a/02 685a/02 685a/02 685a/03 685a/03 685a/03 685a/03 Single contact standard conventional mounting base (Zener diode) Double contact standard conventional mounting base (Zener diode) Single contact conventional mounting base (without diode) Single contact conventional mounting base (Schottky diode) Double contact conventional mounting base (Schottky diode) Single contact standard conventional mounting base (Zener diode) Single contact conventional mounting base (Schottky diode) Double contact conventional mounting base (Schottky diode) Cooper Sécurité SAS Parc Européen d’Entreprises II, Rue Beethoven, BP 10184, 63204 Riom Cedex, France Tel: +44 (0)1302 3397 • Fax: +44 (0)1302 303220 E-mail: [email protected] Certificate No: 685j-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 685h-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006 20 Oct 2014 257 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Point Smoke Detectors Certificated Products DOFS3000 DOFA3000 Bases NUG30256 NUG30255 NUG30257 NUG30258 Conventional photoelectric smoke detector and NUG30257 bases) Intelligent analogue addressable photoelectric smoke detector and NUG30258 bases) LPCB Ref. No. 685h/01 685j/01 Standard analogue addressable mounting base Standard conventional mounting base Double contact standard conventional mounting base Double contact standard analogue addressable mounting base Certificate No: 685m-(cl-3) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Heat Detectors Certificated Products DTVA3000 Bases NUG30256 NUG30258 Intelligent analogue addressable Class P heat detector and NUG30258 bases) Notes: 1. Meets the requirements of EN 54-5 at classes A1R, BS and CS LPCB Ref. No. 685m/01 Single contact standard analogue addressable mounting base Double contact standard analogue addressable mounting base Certificate No: 685k-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 , EN 54-17: 2005 and CEA4021: July 2003(en) Certificate No: 685g-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Multi-Criteria Detectors Certificated Products DMCFS3000 Conventional photo/thermal multisensor and Class A2S heat detector and NUG30257 bases) Intelligent analogue addressable Class A2S multisensor opto/heat detector and NUG30258 bases) Notes: 1. Meets the requirements of EN 54-5 and EN 54-7in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S) DMCFA3000 Bases NUG30255 NUG30256 NUG30257 NUG30258 LPCB Ref. No. 685g/01 685k/01 Standard conventional mounting base Standard analogue addressable mounting base Double contact standard conventional mounting base Double contact standard analogue addressable mounting base Certificate No: 685a-(cl-3) to EN 54-5: 2000 + A1: 2002 Point Heat Detectors Certificated Products DTVS3000 DTS77°S3000 DTS90°S3000 Conventional Class A2R heat detector and NUG30257 bases) Conventional Class BS heat detector and NUG30257 bases) Conventional Class CS heat detector and NUG30257 bases) LPCB Ref. No. 685a/01 685a/02 685a/03 Bases NUG30255 Single contact standard conventional mounting base NUG30257 Double contact standard conventional mounting base 258 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Detector Electronics Corporation 6901 West 110th Street, Minneapolis, Minesota 55438, USA Tel: +001 952 946 6488 E-mail: [email protected] • Website: www.det-tronics.com Certificate No: 973a to EN 54-10: 2002 + A1: 2005 and EN 54-17: 2005 Certificate No: 973e to EN 54-10: 2002 + A1: 2005 Certificated Products X9800 Addressable Class 1 IR flame detector with short circuit isolator Note : The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Addressable Class 1 UV / IR flame detector with short circuit isolator Note : The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Addressable Class 1 multispectrum IR flame detector with short circuit isolator Note: The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Addressable Class 1 UV flame detector with short circuit isolator Note: The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Conventional Class 1 IR flame detector Conventional Class 1 UV / IR flame detector Conventional Class 1 multispectrum IR flame detector Conventional Class 1 UV flame detector X5200 X3301 X2200 X9800 X5200 X3301 X2200 LPCB Ref. No. 973a/01 973a/02 973a/03 973a/04 973e/01 973e/02 973e/03 973e/04 EDS Elektronik Destek San. ve Tic. Ltd. Şti. Meclis Mah. Teraziciller Cad., Kilic Sok., No. 4, Istanbul, 34785 Sangazi, Turkey Tel: +44 (216) 5284500 • Fax: +44 (216) 3141780 Certificate No: 1086a to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products EC-P2L EC-P2L-3 Base: EC-DB EC-DB3 Conventional optical smoke detector 5 pin (EC-DB base) Conventional optical smoke detector 3 pin (EC-DB3 base) LPCB Ref. No. 1086a/01 1086a/02 5 pin base 3 pin base Emergi-Lite Safety Systems (Thomas & Betts Ltd) Bruntcliffe Lane, Morley, Leeds LS27 9LL, United Kingdom Tel: +44 (0)113 2810600 • Fax: +44 (0)113 2810601 Website: www.emergi-lite.co.uk Certificate No: 010p to EN 54-5:2000 + A1:2002 20 Oct 2014 259 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Point Heat Detectors Certificated Products FADY-TEM FAP6-RR6 FAP6-RR75 FAP6-RR90 FAP6-FT8 Analogue addressable heat detector (FA95-ACB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 Class A1R in mode 1 and in conventional mode Class A2 in mode 2 and in conventional mode Class A2S in mode 3 and in conventional mode Class CR in mode 4 and in conventional mode Class CS in mode 5 and in conventional mode 2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions. Conventional Class A1R heat detector (FAP6-STB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 - Class A1R Conventional Class BR heat detector (FAP6-STB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 - Class BR Conventional Class CR heat detector (FAP6-STB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 - Class CR Conventional Class CS heat detector (FAP6-STB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 - Class CS LPCB Ref. No. 010p/03 010p/06 010p/09 010p/12 010p/15 Bases: FAP6-STB Mounting base Certificate No: 010q to EN 54 - 7:2000 + A1:2002 Point Smoke Detectors Certificated Products FADY-OPT FAP6-ION FAP6-OPT Analogue addressable optical smoke detector (FA95-ACB mounting base) Notes: 1) Meets the requirements of EN54: Part 7 in modes 1, 2, 3, 4 and 5 and in conventional mode. 2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions. Conventional ionisation smoke detector (FAP6-STB mounting base) Conventional optical smoke detector (FAP6-STB mounting base) LPCB Ref. No. 010q/03 010q/06 010q/12 Bases; FAP6-STB Mounting base Certificate No: 010h to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002, CEA 4021:2003 Multi-criteria Detectors Certificated Products FADY-MUS Analogue addressable multisensor detector (FA95-ACB mounting base) Notes: 1) Certificated at the following settings: Mode 1 - High sensitivity smoke detector with standard heat enhancement Mode 2 - Smoke detection only Mode 3 - Medium sensitivity smoke detector with standard heat enhancement Mode 4 - Low sensitivity smoke detector with high heat enhancement Mode 5 - Class A1 heat detector Also approved in conventional alarm modes 1, 2, 3, 4 and 5 2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions. LPCB Ref. No. 010h/01 Bases: FA95-ACB Mounting base FAP6-STB Diode mounting base 260 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Emirates Fire Fighting Equipment Factory L.L.C. (FIREX) P.O.Box 22436, Industrial Area 13, Sharjah, United Arab Emirates Tel: +971 6 5340300 • Fax: +971 6 5340090 E-mail: [email protected] • Website: www.firexuae.com Certificate No: 506a to EN 54-7: 2000 Point Smoke Detectors Certificated Products FX-0311-2 FX-0311-3 FX-0311-4 (2 - wire) Conventional photoelectric smoke detector (AHMB-031 Base) (3 - wire) Conventional photoelectric smoke detector (AHMB-031 Base) (4 - wire) Conventional photoelectric smoke detector (AHMB-031 Base) LPCB Ref. No. 506a/02 506a/03 506a/04 Bases: AHMB-031 mounting base Certificate No: 506b to EN 43-7: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002 and CEA 4021: 2003 Multi-criteria Detectors Certificated Products FX-0315-2 FX-0315-3 FX-0315-4 (2 - wire) Optical smoke and Class A2 heat detector (AHMB-31 Base) (3 - wire) Optical smoke and Class A2 detector (AHMB-31 Base) (4 - wire) Optical smoke and Class A2 heat detector (AHMB-31 Base) LPCB Ref. No. 506b/01 506b/02 506b/03 Bases: AHMB-031 mounting base Certificate No: 506c to EN54-5: 2000 Point Heat Detector Certificated Products FX-0316-2 FX-0316-3 FX-0316-4 (2 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB31 Base) (3 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB031 Base) (4 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB31 Base) LPCB Ref. No. 506c/01 506c/02 506c/03 Bases: AHMB-031 mounting base Emirates Fire Protections Equip. Factory. TR. Section Behind the Fourth Industrial Estate, Industrial Area 3, UAE PO 22436, Sharjah, United Arab Emirates Tel: 00971 653 40300 • Fax: 00971 653 40090 E-mail: [email protected] • Website: www.firexuae.com Certificate No: 548c-(cl-3) to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products FX9103 FX9103I Conventional heat detector Class A1R (DZ-03 base) Intelligent Rate of Rise Heat Detector Class A1R (DZ-03 base) LPCB Ref. No. 548c/01 548c/02 Bases: 20 Oct 2014 261 PART 1: SECTION 4.1 COMMERCIAL DETECTORS DZ-03 Standard detector base Certificate No: 548d-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products FX9102 FX9102I LPCB Ref. No. 548d/01 Conventional Photoelectric Smoke Detector (DZ-03 base) Intelligent Photoelectric Smoke Detector (DZ-03 base) 548d/02 Bases: DZ-03 Standard detector base Certificate No: 548k-(cl-2) to EN 54-12: 2002 Beam Detectors Certificated Products FX9105RI LPCB Ref. No. 548k/01 Intelligent optical beam detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31dB Certificate No: 548q-(cl-2) to EN 54:5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA 4021: 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products FX9101 FX9101I LPCB Ref. No. 548q/01 Conventional Optical Smoke and Heat Multisensor Detector (FX9907, DZ-03D & DZ-03 Bases) Notes:1. Meets the requirements of EN 54-7: 2000 at sensitivity setting Mode 12. Meets the requirements of EN 54-5: 2000 at Class A2R Intelligent Optical Smoke and Heat Multisensor Detector (DZ-03 Base) Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity setting Mode 12. Meets the requirements of EN 54-5: 2000 at Class A2R 548q/02 Bases: DZ-03 Standard Base DZ-03D Diode Base FX9907 Active EOL Base Eurofyre Limited Unit C1 Knowle Village Business Park, Mayles Lane, Wickham, Fareham PO17 5DY, United Kingdom Tel: 01329 830 462 E-mail: [email protected] Certificate No: 1163a-(cl-1) to EN54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products 12-020 16-050 Conventional Optical Smoke Detector (12-030 base and 12-031 base) Note:1. Meets the requirements of EN 54-7:2000 at Smoke Sensitivity setting range:0.08%dB~ 0.12%dB Addressable Optical Smoke Detector (12-030 base and 12-031 base) Note: 1. Meets the requirements of EN 54-7:2000 at Smoke Sensitivity setting range:0.09%dB~ 0.11%dB LPCB Ref. No. 1163a/01 1163a/02 Bases: 262 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS 12-030 12-031 Shallow Base Deep Base Certificate No: 1163b-(cl-1) to EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-5:2000 + A1: 2002 & CEA 4021 July 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products 12-023 Conventional Optical Heat Detector (12-030 base and 12-031 base) Note: 1. Meets the requirements of EN 54-7:2000 at Smoke Sensitivity setting range:0.08%dB~ 0.12%dB 2. Meets the requirements of EN 54-5:2000 at Class A2 Addressable Optical Heat Detector (12-030 base and 12-031 base) Note: 1. Meets the requirements of EN 54-7:2000 at Smoke Sensitivity setting range:0.09%dB~ 0.12%dB 2. Meets the requirements of EN 54-5:2000 at Class A1 16-053 Bases: 12-030 12-031 LPCB Ref. No. 1163b/01 1163b/02 Shallow Base Deep Base Certificate No: 1163c-(cl-1) to EN54-5: 2000 + A1: 2002 Heat Detectors Certificated Products 12-022 Conventional A2S Heat Detector (12-030 base and 12-031 base) Note: 1. Meets the requirements of EN 54-5:2000 at Class A2S Conventional A2R Heat Detector (12-030 base and 12-031 base) Note: 1. Meets the requirements of EN 54-5:2000 at Class A2R Addressable A2S Heat Detector (12-030 base and 12-031 base) Note: 1. Meets the requirements of EN 54-5:2000 at Class A2S Addressable A1R Heat Detector (12-030 base and 12-031 base) Note: 1. Meets the requirements of EN 54-5:2000 at Class A1R 12-021 16-052 16-051 Bases: 12-030 12-031 LPCB Ref. No. 1163c/01 1163c/02 1163c/03 1163c/04 Shallow Base Deep Base Eurotech Fire Systems Limited 19/20 Stratfield Park, Elettra Avenue, Waterlooville, Hampshire PO7 7XN, United Kingdom Tel: +44 (0)203 141 0999 • Fax: +44 (0)239 225 2554 E-mail: [email protected] • Website: www.eurotechfire.com Certificate No: 041f-(cl-1) to EN54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 842a-(cl-2) to EN54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 1213e to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 1213n to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005 Smoke Detectors Certificated Products EURV-P EURVC-P 20 Oct 2014 Analogue addressable optical smoke detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only. Conventional optical smoke detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) LPCB Ref. No. 041f/01 041f/03 263 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 200-404 200-503 100-2210V 100-2101V EURVC-P EURV-P Odyssey Conventional Optical Smoke Detector (200-300 and 200-301 mounting base) Odyssey Analogue Addressable Optical Smoke Detector (200-111 mounting base) EURVC-P Conventional Optical Smoke Detector (100-3500V, 100-3511v and 100-3510V bases) EURV-PI Intelligent Optical Smoke Detector with Short Circuit Isolator (100-3000V Base) Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:Optical only level 1 - HighOptical only level 2Optical only level 3 Optical only level 4 - Low Conventional optical smoke detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Analogue addressable optical smoke detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only. LPCB Ref. No. 1213e/01 1213e/02 1213e/04 1213n/01 842a/01 842a/04 Bases EURB-4 Universal mounting base EURB-4-EV Universal mounting base EURB-4SD Universal mounting base with schottky diode EURB-4SE-EV Standard deep base 200-300 Odyssey mounting base 200-111 Odyssey mounting base 200-301 Odyssey diode mounting base 100-3000V Low profile adaptor base Certificate No: 041g-(cl-1) to EN 54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 1999 Certificate No: 041h-(cl-1) to EN54-5: 2000 + A1: 2002 Certificate No: 1213r to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005 Certificate No: 1213d to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products EURV-PH EURV-H-A1R EURV-H-CS EURVC-H-A2S EURVC-H-CS 200-400 Analogue addressable optical smoke / class A1R heat detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings. Analogue addressable Class A1R heat detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Analogue addressable Class CS heat detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Conventional Class A2S heat detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Conventional Class CS heat detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Odyssey Conventional Class A1R Heat Detector (200-300 mounting base) Note: 1. Meets the requirements of EN 54: Part 5 - Class A1R LPCB Ref. No. 041g/01 041h/01 041h/02 041h/03 041h/04 1213d/01 200-401 Odyssey Conventional Class BR Heat Detector (200-300 mounting base) Note: 1. Meets the requirements of EN 54: Part 5 - Class BR 1213d/02 200-402 Odyssey Conventional Class CR Heat Detector (200-300 mounting base) Note: 1. Meets the requirements of EN 54: Part 5 - Class CR 1213d/03 200-403 Odyssey Conventional Class CS Heat Detector (200-300 mounting base) Note: 1. Meets the requirements of EN 54: Part 5 - Class CS 1213d/04 200-501 Odyssey Analogue Addressable Class A2S Heat Detector (200-111 mounting base) 1213d/05 264 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 200-502 100-2505V 100-2201V Odyssey Analogue Addressable Class CS Heat Detector (200-111 mounting base) EURV-H Conventional Class P Heat Detector 100-3511v and 100-3510V bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B EURV-H-A1RI Intelligent Class P Heat Detector with Short Circuit Isolator (100-3000V Base) Note: 1. Meets the requirements of EN 54-5 for Class A1R, Class B and Class BS LPCB Ref. No. 1213d/06 1213d/08 1213r/01 Bases EURB-4 Universal mounting base EURB-4-EV Universal mounting base EURB-4SD Universal mounting base with schottky diode EURB-4SE-EV Standard deep base 200-300 Odyssey mounting base 200-111 Odyssey mounting base 100-3000V Low profile adaptor base Certificate No: 1213c to EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003 Certificate No: 1213p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 & CEA 4021: 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products 200-505 100-2401V Odyssey Analogue Addressable Multisensor Detector (200-111 mounting base) EURV-PHI Intelligent Multi-Criteria Detector with Short Circuit Isolator (100-3000V Base) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No. 1213c/01 1213p/01 Bases: 200-111 Odyssey mounting base 100-3000V Low profile adaptor base Everday Technology Co. Limited No,.95., Sec. 2., Ligong 1 St. Road., Letzer Industrial Park, Yilan County 26841, Taiwan ROC Tel: +886 3 990 6099 • Fax: +862 3 990 6029 E-mail: [email protected] • Website: www.everday.com Certificate No: 512a to EN 54-7: 2000 + A1: 2002 + A2: 2006 20 Oct 2014 265 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Smoke Detectors Certificated Products EA318-2 EA318-2(LED) EA318-4-12 EA318-4-24 EA318-2V EA318-2-LED-V EA318-4V-12 EA318-4V-24 Conventional 2 wire photoelectric smoke detector (P/N852001 base) Conventional 2 wire photoelectric smoke detector with remote LED output (P/N854001 base) Conventional 4 wire photoelectric smoke detector (P/N854001 base) Conventional 4 wire photoelectric smoke detector (P/N854001 base) Conventional 2 wire photoelectric smoke detector (P/N852001 base) Conventional 2 wire photoelectric smoke detector with remote LED output (P/N852001 base) Conventional 4 wire photoelectric smoke detector (P/N854001 base) Conventional 4 wire photoelectric smoke detector LPCB Ref. No. 512a/01 512a/02 512a/03 512a/04 512a/05 512a/06 512a/07 512a/08 Bases: P/N854001 4-wire detector base P/N852001 2-wire detector base Certificate No: 512b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003 Multi-criteria Detectors Certificated Products EA318-2H EA318-2H-LED EA318-4H-12 EA318-4H-24 EA318-2HV EA318-2H-LED-V EA318-4HV-12 EA318-4HV-24 Conventional 2 wire photoelectric smoke and heat detector (P/N852001 base) Conventional 2 wire photoelectric smoke and heat detector with remote LED output (P/N854001 base) Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base) Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base) Conventional 2 wire photoelectric smoke and heat detector (P/N852001 base) Conventional 2 wire photoelectric smoke and heat detector with remote LED output (P/N8524001 base) Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base) Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base) LPCB Ref. No. 512b/01 512b/02 512b/03 512b/04 512b/05 512b/06 512b/07 512b/08 Bases: P/N854001 4-wire detector base P/N852001 2-wire detector base Certificate No: 512d to EN 54-5: 2000 + A1: 2002 Point Heat Detectors Certificated Products EA323-2 EA323-2 EA323-2L EA323-2L EA323-4 EA323-4 EA323-4 EA323-4 EA323-2V(A2S) 266 Conventional 2 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector (P/N852001 base) Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector (P/N852001 base) Conventional 2 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base) Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base) Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 4 wire 12VDC class A2R fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 4 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 4 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 2 wire 24 VDC class A2S fixed temperature and rate-of-rise heat detector LPCB Ref. No. 512d/01 512d/02 512d/03 512d/04 512d/05 512d/06 512d/07 512d/08 512d/09 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products EA323-2V(A2R) EA323-2LV(A2S) EA323-2LV(A2R) EA323-4V-12(A2S) EA323-4V-12(A2R) EA323-4V-24(A2S) EA323-4V-24(A2R) LPCB Ref. No. (P/N852001 base) Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector (P/N852001 base) Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (P/N852001 base) Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 4 wire 12VDC class A2R fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 4 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 4 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector (P/N854001 base) 512d/10 512d/11 512d/12 512d/13 512d/14 512d/15 512d/16 Bases: P/N852001 2-Wire detector base P/N854001 4-Wire detector base Fike Safety Technology Ltd Unit 31, Springvale Industrial Estate, Cwmbran, Gwent NP44 5BD, United Kingdom Tel: +44 (0)1633 865558 • Fax: +44 (0)1633 866656 E-mail: [email protected] • Website: www.fikesafetytechnology.co.uk Certificate No: 331f to EN 54-3: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005, EN 54-18: 2005 and CEA 4021:July 2003 (en) Certificate No: 331n to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17:2005, EN 54-18: 2005 and CEA 4021:July 2003 (en) Certificate No: 331g to EN 54-3: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: July 2003 (en) Certificate No: 331p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: July 2003 (en) Certificate No: 331u to EN 54-5:2000 + A1:2002 & EN 54-7:2000 + A1:2002 + A2:2006 & CEA 4021: 2003 Multi-Sensor Detectors Certificated Products 205-0001 Sita analogue addressable optical smoke and heat multisensor detector with short circuit isolator and sounder. Notes: 1. Meets the requirements of EN 54-5:2000 at the following settings: HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature. 2. LPCB Ref. No. 331f/01 Meets the requirements of EN 54-7:2000 at the following settings: SM1 Standard optical sensitivity with high thermal enhancement SM2 Standard optical sensitivity with normal thermal enhancement. 3. 205-0012 Approved at the following tones SP1 Continuous 970Hz SP2 Pulsed 970Hz 1s on 1s off SP3 Dual Tone 970Hz 0.25s , 800Hz 0.25s SP4* Sweep Up 800-970Hz over 1s SP5 Slow Whoop 500-1200Hz over 3s, 0.5s off SP6* Sweep Down 1200-500Hz over 1s SP7 Dual French 550Hz 0.1s, 440Hz 400ms * Not available if the I/O facility is used. Sita analogue addressable optical smoke and heat multisensor detector with short circuit isolator and sounder/strobe. Notes: 1. Meets the requirements of EN 54-5:2000 at the following settings: HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature. 2. 20 Oct 2014 331f/02 Meets the requirements of EN 54-7:2000 at the following settings: SM1 Standard optical sensitivity with high thermal enhancement SM2 Standard optical sensitivity with normal thermal enhancement. 267 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. 3. 202-0001 Approved at the following tones SP1 Continuous 970Hz SP2 Pulsed 970Hz 1s on 1s off SP3 Dual Tone 970Hz 0.25s , 800Hz 0.25s SP4* Sweep Up 800-970Hz over 1s SP5 Slow Whoop 500-1200Hz over 3s, 0.5s off SP6* Sweep Down 1200-500Hz over 1s SP7 Dual French 550Hz 0.1s, 440Hz 400ms * Not available if the I/O facility is used. 4. The strobe function is not approved. Twinflex conventional optical smoke and heat multisensor detector with sounder Notes: 1. Meets the requirements of EN 54-5:2000 at the following settings: HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature. 331g/01 2. Meets the requirements of EN 54-7:2000 at the following settings: SM1 Standard optical sensitivity with high thermal enhancement SM2 Standard optical sensitivity with normal thermal enhancement. 204-0001 204-0012 205-0003 3. Approved at the following tones SP1 Continuous 970Hz SP2 Alternating Tone 800 0.25s / 970Hz 0.25s SP3 Sweep Up 800-970Hz over 1s Twinflex Multipoint ASD Conventional Optical Smoke and Heat Multisensor Detector with Type A Sounder (45-0048-202-01 Base) Notes: 1. Meets the requirements of EN 54-5:2000 at the following settings: HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature HM3 Class C standard temperature, fixed temperature 2. Meets the requirements of EN 54-7:2000 at the following settings: SM1 Standard optical sensitivity with high thermal enhancement SM2 Standard optical sensitivity with normal thermal enhancement 3. Approved at the following tones SP1 Continuous 970Hz SP2 Pulsed 970Hz 1s on, 1s off SP3 Dual Tone 970Hz 0.25s / 800Hz 0.25s Twinflex Multipoint ASD Conventional Optical Smoke and Heat Multisensor Detector with Type A Sounder & Strobe Notes: 1. Meets the requirements of EN 54-5:2000 at the following settings: HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature HM3 Class C standard temperature, fixed temperature 2. Meets the requirements of EN 54-7:2000 at the following settings: SM1 Standard optical sensitivity with high thermal enhancement SM2 Standard optical sensitivity with normal thermal enhancement 3. Approved at the following tones SP1 Continuous 970Hz SP2 Pulsed 970Hz 1s on, 1s off SP3 Dual Tone 970Hz 0.25s / 800Hz 0.25s 4. The strobe function is not approved to EN 54-23:2010 Sita analogue addressable optical smoke and heat multisensor detector with short circuit isolator. Notes: 1. Meets the requirements of EN 54-5:2000 at the following settings: HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature. 331g/03 331n/01 2. 202-0003 Meets the requirements of EN 54-7:2000 at the following settings: SM1 Standard optical sensitivity with high thermal enhancement SM2 Standard optical sensitivity with normal thermal enhancement. Twinflex conventional optical smoke and heat multisensor detector Notes: 1. Meets the requirements of EN 54-5:2000 at the following settings: HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature. 331g/02 331p/01 2. Meets the requirements of EN 54-7:2000 at the following settings: 268 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 204-0003 200-0013 LPCB Ref. No. SM1 Standard optical sensitivity with high thermal enhancement SM2 Standard optical sensitivity with normal thermal enhancement. Twinflex Multipoint ASDConventional Optical Smoke and Heat Multisensor Detector (450048-202-01 Base) Notes: 1. Meets the requirements of EN 54-5:2000 at the following settings: HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature HM3 Class C standard temperature, fixed temperature 2. Meets the requirements of EN 54-7:2000 at the following settings: SM1 Standard optical sensitivity with high thermal enhancement SM2 Standard optical sensitivity with normal thermal enhancement Conventional Optical Heat Detector Note: 1. Meets the requirements of EN 54-7:2000 at Smoke Sensitivity setting Range:0.08%dB~ 0.12%dB 2. Meets the requirements of EN 54-5:2000 at Class A2 331p/02 331u/01 Bases 45-0048-202 ASD Base 45-0048-202-01 Standard Base 25-0065-202 Base extension 45-0306-202 Twinflex Multipoint Base 200-0014 Shallow Base Certificate No: 331t to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products 200-0010 Conventional Optical Smoke Detector Note: 1. Meets the requirements of EN 54-7:2000 at Smoke Sensitivity setting Range:0.08%dB~ 0.12%dB LPCB Ref. No. 331t/01 Base 200-0014 Shallow Base Certificate No: 331s to EN 54-5: 2000 + A1:2002 Heat Detectors Certificated Products 200-0012 200-0011 Conventional A2S Heat Detector Note: 1. Meets the requirements of EN 54-5: 2000 at Class A2S Conventional A2R Heat Detector Note: 1. Meets the requirements of EN 54-5: 2000 at Class A2R LPCB Ref. No. 331s/01 331s/02 Base 200-0014 Shallow Base 20 Oct 2014 269 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Finder Elektronik A.S. Liman Mah., 6. Sok., No: 10 07070, Konyaalti, Antalya, Turkey Tel: +9 0242 344 2500 • Fax: +9 0242 344 2120 E-mail: [email protected] • Website: www.finder.com.tr Certificate No: 928a-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54 -17: 2005 Certificate No: 928d-(cl-1) to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products FF T200 Analogue addressable Class P heat detector with short circuit isolator (FF BS200 base) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable Class P, temperature detector (FF BS200 base) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B Conventional Class P, heat detector (FF UBR200 and FF BRD200 bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B. FF T200L FF T1000 Bases FF BS200 FF UBR200 FF BRD200 LPCB Ref. No. 928a/01 928d/01 928d/02 Mounting base (with link resistor) Universal adaptor base with resistor Universal adaptor base with resistor and Schottky diode Certificate No: 928b-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005 Certificate No: 928e-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 928k-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008 Smoke Detectors Certificated Products FF O200 FF O200L FF O1000 FF SG100 Bases FF BS200 FF UBR200 FF BRD200 WAB100 270 Analogue addressable photoelectric smoke detector with short circuit isolator (FF BS200 base) Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable optical smoke detector (FF BS200 base) Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Conventional photo smoke detector (FF UBR200 and FF BRD200 bases) Wireless optical smoke detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-7 in the normal sensitivity setting 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928b/01 928e/01 928e/02 928k/01 Mounting base (with link resistor) Universal adaptor base with resistor Universal adaptor base with resistor and Schottky diode Wireless Adaptor Base 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 928c-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA 4021: 2003 Certificate No: 928f-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Multi-sensor Detectors Certificated Products FT OT200 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (FF BS200 base) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable optical smoke detector (FF BS200 base) Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low FF OT200L Bases FF BS200 LPCB Ref. No. 928c/01 928f/01 Mounting base (with link resistor) Certificate No: 928j-(cl-5) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008 Point Heat Detectors Certificated Products FF SG350 Bases: WAB100 Wireless heat detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1R 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928j/01 Wireless Adaptor Base Certificate No: 928m-(cl-5) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003 Multi-Criteria Detectors Certificated Products FF SG200 Bases: WAB100 20 Oct 2014 Wireless multi-criteria detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1 2. Meets the requirements of EN 54-7 in the normal sensitivity setting 3. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928m/01 Wireless Adaptor Base 271 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Fire Fighting Enterprises Ltd 9 Hunting Gate, Hitchin, Hertfordshire SG4 0TJ, United Kingdom Tel: +44 (0) 1462 444740 • Fax: +44 (0) 1462 444789 E-mail: [email protected] • Website: www.ffeuk.com Certificate No: 1204a to EN 54-10: 2002 + A1: 2005 Commercial detectors -1 - 1 - 4 Certificated Products 16511 16519 16521 16571 16579 16581 16589 16591 Talentum Conventional IR2 (Exd) Flameproof Flame Detector (07127 Bracket) Note: 1.) Meets the requirements of EN 54-10: 2002 at Class 1 only Talentum Conventional IR3 (Exd) Flameproof Flame Detector (07127 Bracket) Note: 1.) Meets the requirements of EN 54-10: 2002 at Class 1 only Talentum Conventional UV/IR2 (Exd) Flameproof Flame Detector (07127 Bracket) Note: 1.) Meets the requirements of EN 54-10: 2002 at Class 1 only Talentum Conventional IR2 (IS) Intrinsically Safe Flame Detector (07127 Bracket) Note: 1.) Meets the requirements of EN 54-10: 2002 at Class 1 only Talentum Conventional IR3 (IS) Intrinsically Safe Flame Detector (07127 Bracket) Note: 1.) Meets the requirements of EN 54-10: 2002 at Class 1 only Talentum Conventional IR2 Flame Detector (07127 Bracket) Note: 1.) Meets the requirements of EN 54-10: 2002 at Class 1 only Talentum Conventional IR3 Flame Detector (07127 Bracket) Note: 1.) Meets the requirements of EN 54-10: 2002 at Class 1 only Talentum Conventional UV/IR2 Flame Detector (07127 Bracket) Note: 1.) Meets the requirements of EN 54-10: 2002 at Class 1 only LPCB Ref. No. 1204a/05 1204a/06 1204a/07 1204a/08 1204a/09 1204a/10 1204a/11 1204a/12 07127 Adjustable Mounting Bracket Fireguard Safety Equipment Co Ltd 2nd Floor, 145-147 St John Street, London EC1V 4PY, United Kingdom Tel: +44 (0)8450 751042 • Fax: +44 (0)845 2991039 E-mail: [email protected] • Website: www.fireguard-uk.com Certificate No: 512a-(cl-4) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 928e-(cl-7) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 1138a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificated Products FG-413SD-4 FG-413SD-2 Fireguard FG318-2L FGSD100 272 Conventional 4-WIRE Photoelectric Smoke Detector with Relay Output (B-01 base) Conventional 2-WIRE Photoelectric Smoke Detector with Remote LED (B-01 base) Conventional 2 wire photoelectric smoke detector with remove LED output (Fireguard P/N FG854001 base) Analogue addressable photoelectric smoke detector lite (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No. 1138a/03 1138a/04 512a/02 928e/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Bases VB100 UB100 VB100S UB100S VDBS100 DBS100 VDBS100S DBS100S Fireguard P/N FG854001 B-01 Vega adaptor base (with link resistor) Universal adaptor base Vega adaptor base with shorting clip Universal adaptor base with shorting clip Vega deep adaptor base Deep adaptor base Vega deep adaptor base with shorting clip Deep adaptor base with shorting clip 4 wire detector base Standard Base Certificate No: 512d-(cl-4) to EN54-5: 2000 + A1: 2002 Certificate No: 928d-(cl-7) to EN 54-5: 2000 + A1: 2002 Certificated Products Fireguard FG323-2L FGHD350 Bases VB100 UB100 VB100S UB100S VDBS100 DBS100 VDBS100S DBS100S Fireguard P/N FG854001 Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (Fireguard P/N FG854001 base) Analogue addressable Class P heat detector lite (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 512d/04 928d/01 Vega adaptor base (with link resistor) Universal adaptor base Vega adaptor base with shorting clip Universal adaptor base with shorting clip Vega deep adaptor base Deep adaptor base Vega deep adaptor base with shorting clip Deep adaptor base with shorting clip 4 wire detector base Firelite by Honeywell (Pittway Systems Technology Group (Europe) Ltd) Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 1444 230 300 • Fax: +44 1444 230 888 E-mail: [email protected] Certificate No: 550a to EN 54-7: 2000 + A1: 2002 Certificate No: 550b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 and CEA 4021: 1999 Certificate No: 550c to EN 54-5: 2000 + A1: 2002 Multi-Sensor/Multi-Criteria Detectors Certificated Products FL/1003 FL/1002 FL/1005 Conventional photoelectric smoke detector (FL/1000B base) Conventional optical/thermal detector (FL/1000B base) Notes: 1. Meets the requirements of EN54-5 at class A1R at pre-set sensitivity. Conventional Class A1R rate of rise heat detector (FL/1000B base) LPCB Ref. No. 550a/02 550b/02 550c/03 Bases FL/1000B standard base 20 Oct 2014 273 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Fireonica Co. Ltd 2 The Dingle, Wolverhampton WV3 9ET, United Kingdom Tel: 01902 762 163 • Fax: 0845 299 1039 E-mail: [email protected] Certificate No: 928d-(cl-8) to EN 54-5: 2000 + A1: 2002 Certificate No: 928e-(cl-8) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificated Products FOHD350 Analogue addressable Class P heat detector lite (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable photoelectric smoke detector lite (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low FOSD100 Bases VB100 UB100 VB100S UB100S VDBS100 DBS100 VDBS100S DBS100S LPCB Ref. No. 928d/01 928e/01 Vega adaptor base (with link resistor) Universal adaptor base Vega adaptor base with shorting clip Universal adaptor base with shorting clip Vega deep adaptor base Deep adaptor base Vega deep adaptor base with shorting clip Deep adaptor base with shorting clip Fsc Export Ltd Northolt UB5 5BX, United Kingdom Tel: +44 7086465266 E-mail: [email protected] Certificate No: 506a-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificated Products FS-CSD-311-2 FS-CSD-311-3 FS-CSD-311-4 wire) Conventional Photoelectric Smoke Detector (AHMB-031 Base) wire) Conventional Photoelectric Smoke Detector (AHMB-031 Base) wire) Conventional Photoelectric Smoke Detector (AHMB-031 Base) LPCB Ref. No. 506a/02 506a/03 506a/04 Base: AHMB-031 Mounting Base Certificate No: 506b-(cl-4) to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002, CEA 4021: 2003 Certificated Products FS-CMD-300-2 FS-CMD-300-3 FS-CMD-300-4 wire) Optical Smoke and Class A2 Heat Detector (AHMB-031 Base) wire) Optical Smoke and Class A2 Heat Detector (AHMB-031 Base) wire) Optical Smoke and Class A2 Heat Detector (AHMB-031 Base) LPCB Ref. No. 506b/01 506b/02 506b-03 Base: AHMB-031 Mounting Base 274 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 506c-(cl-5) to EN 54-5: 2000 + A1: 2002 Certificated Products FS-CTD-805-2 FS-CTD-805-3 FS-CTD-805-4 Wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB-031 Base) Wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB-031 Base) Wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB-031 Base) LPCB Ref. No. 506c/01 506c/02 506c/03 Base: AHMB-031 Mounting Base Gent By Honeywell (Novar Systems Ltd) 140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300 E-mail: [email protected] • Website: www.gent.co.uk Middle East Sales Enquiries: E-mail: [email protected] Certificate No: 042bd to EN54-7: 2000+A1: 2002+A2: 2006, EN54-17: 2005, EN54-18: 2005 Certificate No: 042az to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products 17840-01 Conventional optical smoke detector (17800-01, 17800-02, 17801-01, 17801-02 mounting bases) S4-715 S-Quad analogue addressable optical smoke detector Standard base with or without S4FLUSH semi-flush fixing kit) Note: 1) Meets the requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical LPCB Ref. No. 042az/01 042bd/01 Bases: 78200-01NM standard base 17800-01 standard base 17801-01 standard base with diode 17800-02 low profile base 17801-02 low profile base with diode S4-700 Standard base S4-FLUSH Semi-flush fixing kit Certificate No: 567b to BS 5445: Part 5: 1977 This certificate is to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. Certificate No: 042ak to EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002 + A2: 2006, EN 54-17: 2005 and EN 54-18: 2005 Certificate No: 042be to EN54-5: 2000+A1: 2002, EN54-17: 2005, EN54-18: 2005 Certificate No: 042ay to EN 54-5: 2000 + A1: 2002 Point Heat Detectors Certificated Products S4-780 20 Oct 2014 S-Quad analogue addressable Class P heat detector with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirements of EN 54: Part 5 at the following settings: State 0 - Class A1 LPCB Ref. No. 042ak/01 275 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products S4-720-ST-VO S4-780-ST LPCB Ref. No. State 5 - Class B 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs S-Quad analogue addressable Class P heat detector with strobe and speech (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit Note: 1. Meets the requirements of EN 54: Part 5 at the following settings: State 0 - Class A1 State 5 - Class B 2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3. Strobe not included in scope of approval. 4. Speech function is not approved against Annex C requirements of EN 54-3 042ak/02 S-Quad analogue addressable Class P heat detector with sounder and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1. Meets the requirement of EN 54: Part 5 at the following settings: State 0 - Class A1 State 5 - Class B 2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3. Strobe not included in scope of approval. Conventional Class A1 fixed temperature heat detector (17800-01, 17800-02, 17801-01, 17801-02 mounting bases) 042ak/03 17860-01 Conventional Class A1 rate of rise heat detector (17800-01, 17800-02, 17801-01, 1780102 mounting bases) 042ay/02 S4-720 S-Quad analogue addressable Class P heat detector (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Note: Meets the requirement of EN 54: Part 5 at the following settings: State 0 - Class A1 State 5 - Class B Conventional grade 1 fixed temperature heat detector (17800-01, 17801-01, 17800-02 and 17801-02 bases) Note: This product is certificated to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. Conventional grade 1 rate-of-rise heat detector (17800-01, 17801-01, 17800-02 and 17801-02 bases) Note: This product is certificated to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. 042be/01 17850-01 17850-01 17860 -01 042ay/01 567b/01 567b/02 Bases: 17800-01 standard base 17801-01 standard base with diode 17800-02 low profile base 17801-02 low profile base with diode S4-700 standard base S4-FLUSH semi-flush fixing kit 276 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 042am to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and EN 54-18: 2005 and CEA 4021:2003 Certificate No: 042an to EN 54-5: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1:2002 + A2: 2006, EN 54-17: 2005, EN 54-18: 2005 and CEA 4021: 2003 Certificate No: 042bf to EN54-5: 2000+A1: 2002, EN54-7: 2000+A1: 2002+A2: 2006, EN54-17: 2005, EN54-18: 2005 Certificate No: 042bv to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN54-17: 2005, EN54-18: 2005, EN54-23: 2010 Certificate No: 042ca to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005, Certificate No: 042bu to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005, Certificate No: 042bz to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005, Certificate No: 042bw to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005, EN54-23: 2010 Certificate No: 042ak to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005, Multi-criteria Detectors Certificated Products S4-780-S S4-711-ST S4-911 S4-711-ST-VO S4-771 S4-911-ST-VO 20 Oct 2014 Analogue Addressable Class P Heat Sensor with Sounder (S4-701 Base) Notes:1. Meets the requirements of EN 54-3 at the following tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-3:2001 at the following settings: State 0 - Class A1 heat State 5 - Class B heat 3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat 2) The strobe function is not included within the scope of this approval S-Quad analogue addressable dual optical smoke, Class P heat and carbon monoxide multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 5 at the following settings: State 9 - Class A1 heat 3) Carbon monoxide detection is not included within the scope of this approval S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with speech and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3) Speech function is not approved against Annex C requirements of EN 54-3 S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs S-Quad analogue addressable optical smoke, heat and carbon monoxide multisensor detector LPCB Ref. No. 042ak/04 042am/02 042am/03 042an/01 042an/02 042an/03 277 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products S4-770 S4-711-VO S4-770-ST S4-710 S4-711 S4-911-V-VAD-HPR 278 LPCB Ref. No. with speech and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirements of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 5 at the following settings: State 9 - Class A1 heat 3) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 4) Carbon monoxide detection, speech and strobe not included within the scope of this approval 5) Speech function is not approved against Annex C requirements of EN 54-3 S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Note: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with speech (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Note: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3) Speech function is not approved against Annex C requirements of EN 54-3 S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector with sounder and strobe Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3) Strobe not included in scope of approval. S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Note: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush fixing kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat Analogue Addressable Dual Optical Smoke and Class P Heat and CO Multi-Sensor Detector with Speech, Sounder and Red Visual Alarm (S4-701 Base) Notes: 1. Meets the requirements of EN 54-3 at the following sounder tone settings: High- Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 - Medium Optical / Class A1 Heat State 9 - Class A1 Heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following: 042an/04 042an/05 042an/06 042bf/01 042bf/02 042bu/04 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products S4-911-V-VAD-HPW S4-711-V-VAD-HPR S4711-V-VAD-HPR S4-711-V-VAD-LPW S4-711-V-VAD-HPW 20 Oct 2014 LPCB Ref. No. - Category (light pattern details) @ High power setting - (Category C: C-3-14 and Category O: O-4.5-14) @ Medium power setting - (Category C: C-3-13 and Category O: O-4-13) @ Low power setting - (Category C: C-3-10 and Category O: None) - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Dual Optical Smoke and Class P Heat and CO Multi-Sensor Detector with Speech, Sounder and White Visual Alarm (S4-701 Base) Notes: 1. Meets the requirements of EN 54-3 at the following sounder tone settings: High- Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 - Medium Optical / Class A1 Heat State 9 - Class A1 Heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following: - Category (light pattern details) @ High power setting - (Category C: C-6-16 and Category O: None) @ Medium power setting - (Category C: C-3-14 and Category O: O-5-14) @ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8 - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Speech, Sounder and Red Visual Alarm (S4-701 Base) Notes: 1. Meets the requirements of EN 54-3 at the following sounder tone settings: High- Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 - Medium Optical / Class A1 Heat State 5 - Medium Optical / Class B Heat State 8 - Delayed Medium Optical / Class A1 Heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following: - Category (light pattern details) @ High power setting - (Category C: C-3-14 and Category O: O-4.5-14) @ Medium power setting - (Category C: C-3-13 and Category O: O-4-13) @ Low power setting - (Category C: C-3-10 and Category O: None) - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with Speech, Sounder and White Visual Alarm (S4-701 Base) Notes: 1. Meets the requirements of EN 54-3 at the following sounder tone settings: High- Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 - Medium Optical / Class A1 Heat State 5 - Medium Optical / Class B Heat State 8 - Delayed Medium Optical / Class A1 Heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following: - Category (light pattern details) @ Low power setting - (Category C: C-3-10 and Category O: None) - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Speech, Sounder and White Visual Alarm (S4-701 Base) Notes: 1. Meets the requirements of EN 54-3 at the following sounder tone settings: High- Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 - Medium Optical / Class A1 Heat State 5 - Medium Optical / Class B Heat State 8 - Delayed Medium Optical / Class A1 Heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 042bu/05 042bu/06 042bu/07 042bu/08 279 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products S4-720-V-VAD-HPR S4-720-V-VAD-HPW S4-711-VAD-HPR LPCB Ref. No. for the following: - Category (light pattern details) @ High power setting - (Category C: C-6-16 and Category O: None) @ Medium power setting - (Category C: C-3-14 and Category O: O-5-14) @ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8 - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Class P Heat Sensor with Voice, Sounder and Red Visual Alarm (S4-701 Base) Notes: 1. Meets the requirements of EN 54-3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 at the following settings: State 0 - Class A1 heat State 5 - Class B heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following: - Category (light pattern details) @ High power setting - (Category C: C-3-14 and Category O: O-4.5-14) @ Medium power setting - (Category C: C-3-13 and Category O: O-4-13) @ Low power setting - (Category C: C-3-10 and Category O: None) - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Class P Heat Sensor with Voice, Sounder and White Visual Alarm (S4-701 base) Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 at the following settings: State 0 - Class A1 heat State 5 - Class B heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following: - Category (light pattern details) @ High power setting - (Category C: C-6-16 and Category O: None) @ Medium power setting - (Category C: C-3-14 and Category O: O-5-14) @ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8 - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21CNotes: Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with Red Visual Alarm (S4-701 base) Notes:1. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 -Medium optical / Class A1 heat State 5 - Medium optical / Class B Heat State 8 - Delayed medium optical / Class A1 heat 042bv/01 042bv/02 042bw/01 2. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following: - Category (light pattern details) @ High power setting - (Category C: C-3-14 and Category O: O-4.5-14) @ Medium power setting - (Category C: C-3-13 and Category O: O-4-13) @ Low power setting - (Category C: C-3-10 and Category O: None) - Synchronization - Flash rate 2 seconds (0.5Hz) S4-711-VAD-LPW 3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with White Visual Alarm (S4-701 base) Notes: 1. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 -Medium optical / Class A1 heat State 5 - Medium optical / Class B Heat State 8 - Delayed medium optical / Class A1 heat 042bw/02 2. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following: - Category (light pattern details) @ Low power setting - (Category C: C-3-10 and Category O: None) 280 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. - Synchronization - Flash rate 2 seconds (0.5Hz) S4-711-VAD-HPW 3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with White Visual Alarm (S4-701 base) Note:1. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 -Medium optical / Class A1 heat State 5 - Medium optical / Class B Heat State 8 - Delayed medium optical / Class A1 heat 042bw/03 2. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following: - Category (light pattern details) @ High power setting - (Category C: C-6-16 and Category O: None) @ Medium power setting - (Category C: C-3-14 and Category O: O-5-14) @ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8) - Synchronization - Flash rate 2 seconds (0.5Hz) S4-901 S4-711-V S4-771-S S4-770-S 3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Dual Optical Smoke and Class P Heat and CO Multi-Sensor Detector Base) Notes: 1. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 - Medium optical / Class A1 heat State 9 - Class A1 heat 2. Carbon Monoxide Detection is not included in the scope of this approval. 3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with Speech (S4-701 base) Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 -Medium optical / Class A1 heat State 5 - Medium optical / Class B Heat State 8 - Delayed medium optical / Class A1 heat 3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder (S4-701 base) Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 -Medium optical / Class A1 heat State 5 - Medium optical / Class B Heat State 8 - Delayed medium optical / Class A1 heat 3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder (S4-701 base) Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 -Medium optical / Class A1 heat 3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C 042bz/01 042ca/01 042ca/02 042ca/03 Bases: S4-700 standard base S4-701 S Quad plate and base S4-FLUSH semi-flush fixing kit Certificate No: 042bh to EN 54-12: 2002 and EN 54-17: 2005 Beam Detectors Certificated Products S4-34740 20 Oct 2014 Analogue addressable optical beam smoke detector with short circuit isolator LPCB Ref. No. 042bh/01 281 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. ( S4-34741-01 and S4-34741-03) Notes: 1. The S4-34740 beam sensor pair comprises of an S4-34741 beam transmitter, plus an S4-34742 beam receiver. 2. Meets the requirements of EN 54-12 at the following sensitivity settings: States 0, 1: 3.01dB States 2, 3: 1.25dB Ancillaries: S4-34741-01 beam angle bracket S4-34741-03 beam parallel bracket GEZE GmbH Reinhold-Vöster-Str. 21-29, D-71229 Leonberg, Germany Tel: +49 (0)7152-203-0 • Fax: +49 (0)7152-203-310 E-mail: [email protected] • Website: www.geze.com Certificate No: 928d-(cl-10) to EN 54-5: 2000 + A1: 2002 Point Heat Detectors Certificated Products GC003 D Base GC160 B Conventional non-latching Class P heat detector (GC 150B relay base and GC160 B base) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 928d/02 Universal adaptor base Certificate No: 928e-(cl-10) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products GC002 D Conventional non-latching photo smoke detector (GC150 B relay base and GC160 B base) LPCB Ref. No. 928e/02 Bases GC150 B Non-latching relay base GC160 B Universal adaptor base Gulf Security Technology Co., Ltd. No 80 Changjiang East Road, QETDZ, Qinhuangdao, Hebei Province 066004, China Tel: +86 0335 8502434 • Fax: +86 0335 8502532 E-mail: [email protected] • Website: www.gst.com.cn Sales Enquiries: Tel: +852 28778566 • Fax: +852 25118699 Tel: +86 (10)64392919 • Fax: +86 (10)64391767 Certificate No: 548c to EN 54-5: 2000 + A1: 2002 282 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Point Heat Detectors Certificated Products C-9103 I-9103 DC-9103E Conventional Class A1R heat detector (DZ-03 base) Intelligent Class A1R Rate of Rise Heat Detector (DZ-03 base) Conventional Rate of Rise and Fixed Temperature Heat Detector (DB-01 & DB-01D Bases and DP-9907 Unit) Note: 1. Meets the requirements of EN 54-5:2000 for Class A1R, A2S & BS Intelligent Rate of Rise and Fixed Temperature Heat Detector (DB-01 Base) Note: 1. Meets the requirements of EN 54-5:2000 for Class A1R, A2S & BS DI-9103E Bases: DZ-03 DB-01 DB-01D DP-9907 LPCB Ref. No. 548c/01 548c/02 548c/03 548c/04 Standard detector base Standard Base Diode Base Active End of Line Unit Certificate No: 548d to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detector Certificated Products C-9102 I-9102 DC-9102E Conventional Photoelectric Smoke Detector (DZ-03 base) Intelligent Photoelectric Smoke Detector (DZ-03 base) Conventional Photoelectric Smoke Detector (DB-01 & DB-01D Bases and DP-9907 Unit) Note:1. Meets the requirements of EN 54-7:2000 at sensitivity level 1 (default) setting only Intelligent Photoelectric Smoke Detector (DB-01 Base) Note: 1. Meets the requirements of EN 54-7:2000 at sensitivity level 1 (default) setting only DI-9102E Bases: DZ-03 DB-01 DB-01D DP-9907 LPCB Ref. No. 548d/01 548d/02 548d/03 548d/04 Standard detector base Standard Base Diode Base Active End of Line Unit Certificate No: 548k to EN 54-12: 2002 Beam Detectors Certificated Products I-9105R Intelligent optical beam detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31 dB LPCB Ref. No. 548k/01 Certificate No: 548q to EN54-5: 2000 + A1:2002, EN54-7: 2000 + A1: 2006, CEA 4021: 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products C-9101 I-9101 DC-9101E 20 Oct 2014 Conventional Optical Smoke and Heat Multisensor Detector (P-9907 Base, DZ-03D Base & DZ-03 Base) Notes: 1. Meets the requirements of EN 54-7: 2000 at sensitivity setting Mode 1 2. Meets the requirement of EN 54-5: 2000 at Class A2R Intelligent Optical Smoke and Heat Multisensor Detector (DZ-03 Base) Notes: 1. Meets the requirements of EN 54-7: 2000 at sensitivity setting Mode 1 2. Meets the requirement of EN 54-5: 2000 at Class A2R Conventional Combination Heat/Photoelectric Smoke Detector (DB-01 & DB-01D bases and DP-9907 Unit) Notes:1. Meets the requirements of EN 54-7: 2000 at sensitivity level 1 (default) setting only LPCB Ref. No. 548q/01 548q/02 548q/03 283 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 2. Meets the requirements of EN 54-5: 2000 for Class A2R Conventional Combination Heat/Photoelectric Smoke Detector Intelligent Combination Heat/Photoelectric Smoke Detector (DB-01 base) Notes: 1. Meets the requirements of EN 54-7: 2000 at sensitivity level 1 (default) setting only 2. Meets the requirements of EN 54-5: 2000 for Class A2R DI-9101E Bases: DZ-03 P-9907 DZ-03D DB-01 DB-01D DP-9907 LPCB Ref. No. 548q/04 Standard base Active EOL base Diode Base Standard Base Diode Base Active End of Line Unit Haes Systems Limited Columbia House, Packet Boat Lane, Cowley Peachey, Uxbridge, Middlesex UB8 2JP, United Kingdom Tel: +44 (0)1895 422066 • Fax: +44 (0)1895 420603 E-mail: [email protected] • Website: www.haes-systems.co.uk Certificate No: 810b to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products 55000-122HSL 55000-127HSL 55000-132HSL 55000-137HSL 55000-400HSL 55000-401HSL Series 65 Conventional Class A1R Heat Detector (45681-200HSL mounting base) Note:Meets the requirements of EN 54: Part 5 - Class A1R Series 65 Conventional Class BR Heat Detector (45681-200HSL mounting base) Note:Meets the requirements of EN 54: Part 5 Class BR Series 65 Conventional Class CR Heat Detector (45681-200HSL mounting base) Note:Meets the requirements of EN 54: Part 5 Class CR Series 65 Conventional Class CS Heat Detector (45681-200HSL mounting base) Note:Meets the requirements of EN 54: Part 5 Class CS XP95 Analogue Addressable Class A2S Heat Detector (45681-210HSL mounting base) XP95 Analogue Addressable Class CS High Temperature Heat Detector (45681-210HSL mounting base) LPCB Ref. No. 810b/01 810b/02 810b/03 810b/04 810b/05 810b/06 Bases: 45681-200HSL Series S65 Mounting Base 45681-210HSL Series XP95 mounting base Certificate No: 810c to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products 55000-217HSL 55000-317HSL 55000-500HSL 55000-600HSL Series 65 Conventional Ionisation Smoke Detector (45681-200HSL mounting base) Series 65 Conventional Optical Smoke Detector (45681-200HSL mounting base) XP95 Analogue Addressable Ionisation Smoke Detector (45681-210HSL mounting base) XP95 Analogue Addressable Optical Smoke Detector (45681-210HSL mounting base) LPCB Ref. No. 810c/01 810c/02 810c/03 810c/04 Bases: 284 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS 45681-200HSL Series 60/65 Mounting Base 45681-210HSL Series XP95 Mounting Base Certificate No: 810d to EN 54-7: 2001 + A1: 2002 + A2: 2006 and CEA 4021: 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products 55000-885HSL XP95 Analogue Addressable Multisensor Detector (45681-210HSL mounting base) LPCB Ref. No. 810d/01 Bases: 45681-210HSL Series XP95 Mounting Base HDR Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132 E-mail: [email protected] • Website: www.hochikieurope.com Certificate No: 117f to EN54-7: 2000 + A1: 2002, EN54-5: 2000 + A1: 2002 and CEA 4021: 1999 Multi-Criteria Detectors Certificated Products 1410010 Intelligent analogue addressable multisensor (YBN-R/3 base) Note: Meets EN 54-5 class A1 and B and EN 54-7 at 3.0%/m sensitivity setting in normal and low power mode. LPCB Ref. No. 117f/01 Certificate No: 117g to EN 54 Part 5: 2000 Point Heat Detectors/Sensors Certificated Products 1215110 1215120 1217180 1217190 1410020 Class A1S conventional fixed temperature heat detector (YCA-RL/3H2M, YBN-R/6SK and 1226150) Class CS conventional fixed temperature heat detector (YCA-RL/3H2M, YBN-R/6SK and 1226150 bases) Class A1R conventional rate of rise temperature heat detector (YCA-RL/3H2M, YBNR/6SK and 1226150 bases) Conventional Class CR rate of rise high temperature heat detector (YBN-R/6SK and 1226150 bases) Intelligent analogue addressable Class P heat detector (1426010 and 1226110 bases) Note: Meets requirements of EN54-5: 2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol. LPCB Ref. No. 117g/02 117g/03 117g/04 117g/06 117g/09 Bases: 1226150 Standard base 1426010 Standard base YCA-RL/3H2M Addressable base YBN-R/6SK Schottky diode base Certificate No: 117j to EN 54-12: 2002 Beam Detectors Certificated Products 1213060 1213080 20 Oct 2014 Optical Beam Smoke Detector Note: Certified at a sensitivity setting of 30% obscuration Conventional 2 wire optical beam smoke detector Notes: LPCB Ref. No. 117j/01 117j/03 285 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. 1) Approved at sensitivity setting 25% and 50%. 2) Approved for use with 1213080 2WI interface kit. Certificate No: 358c to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors/Sensors Certificated Products 1412110 Intelligent analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Intelligent analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Conventional optical smoke detector (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) Conventional optical smoke detector (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) 1412120 1212270 1212280 Bases YBN-R/3 YBO-R/SCI YBO-BS YBO-BSB YBN-R/6 YBN-R/6SK YBO-R/6R YBO-R/6RS YBO-R/6RN YBO-R/6PA LPCB Ref. No. 358c/03 358c/04 358c/05 358c/06 Standard base Positive switching short circuit isolator base Sounder base Sounder base with Beacon Standard base Standard base with schottky diode Relay base Relay base latching with schottky diode Relay base non latching Protector alarms base Hochiki America Corporation 7051 Village Drive, Buena Park, California 90621, USA Tel: +1 714 522 2246 • Fax: +1 714 522 2268 E-mail: [email protected] • Website: www.hochiki.com Certificate No: 358d to EN 54-10: 2002 + A1: 2005 Flame Detectors Certificated Products IR3 IR3-IS IR3-EX IR2-UV IR2-UV-EX 3 Conventional IR Flame Detector (IR-AMB) Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR 3 Intrinsically Safe Flame Detector Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR 3 (Exd) Flameproof Flame Detector (IR-AMB) Note: Meets EN 54-10: 2002 at Class 1 only Conventional UV/IR² Flame Detector (IR-AMB) Note: Meets EN 54-10: 2002 at Class 1 only Conventional UV/IR 2 (Exd) Flameproof Flame Detector (IR-AMB) Note: Meets EN 54-10: 2002 at Class 1 only LPCB Ref. No. 358d/01 358d/02 358d/03 358d/04 358d/05 Ancillaries IR-AMB Adjustable Mounting Bracket 286 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 358c to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products ALK-E ALK-E (WHT) ALG-EN ALG-EN (BLK) ALG-EN (WHT) SLV-E3 SLV-E3 (WHT) SLR-E3N SLR-E3N (BLK) SLR-E3N (WHT) ALN-EN ALN-EN (WHT) Intelligent Analogue Addressable Optical Smoke DetectorYBO-R/SCI, YBO-BS & YBOBSB bases) Note:1. Meets the requirements of EN 54-7 in low and high sensitivity setting and in normal and low power modes. Intelligent Analogue Addressable Optical Smoke Detector (White)YBO-R/SCI, YBO-BS & YBO-BSB bases) Note:1. Meets the requirements of EN 54-7 in low and high sensitivity setting and in normal and low power modes. Intelligent Analogue Addressable Optical Smoke DetectorYBO-R/SCI, YBO-BS & YBOBSB bases) Note:1. Meets the requirements of EN 54-7 in low and high sensitivity setting and in normal and low power modes. Intelligent Analogue Addressable Optical Smoke Detector (Black)YBO-R/SCI, YBO-BS & YBO-BSB bases) Note:1. Meets the requirements of EN 54-7 in low and high sensitivity setting and in normal and low power modes. Intelligent Analogue Addressable Optical Smoke Detector (White)YBO-R/SCI, YBO-BS & YBO-BSB bases) Note:1. Meets the requirements of EN 54-7 in low and high sensitivity setting and in normal and low power modes. Conventional Optical Smoke DetectorYBN-R/6SK, YBO-R/6R, YBO-R/6RS, YBO-R/6RN & YBO-R/6PA bases) Conventional Optical Smoke Detector (White)YBN-R/6SK, YBO-R/6R, YBO-R/6RS, YBO-R/6RN & YBO-R/6PA bases) Conventional Optical Smoke Detector YBN-R/6SK, YBO-R/6R, YBO-R/6RS, YBO-R/6RN & YBO-R/6PA bases) Conventional Optical Smoke Detector (Black)YBN-R/6SK, YBO-R/6R, YBO-R/6RS, YBO-R/6RN & YBO-R/6PA bases) Conventional Optical Smoke Detector (White)YBN-R/6SK, YBO-R/6R, YBO-R/6RS, YBO-R/6RN & YBO-R/6PA bases) Intelligent Analogue Addressable Optical Smoke DetectorYBN-R/3, YBO-R/SCI, YBO-BS & YBO-BSB Bases) Note:1. Meets the requirements of EN 54-7 in low and high sensitivity settings. Intelligent Analogue Addressable Optical Smoke Detector (White)YBN-R/3, YBO-R/SCI, YBO-BS & YBO-BSB Bases) Note:1. Meets the requirements of EN 54-7 in low and high sensitivity settings. LPCB Ref. No. 358c/03 358c/03 358c/04 358c/04 358c/04 358c/05 358c/05 358c/06 358c/06 358c/06 358c/07 358c/07 Bases YBN-R/3 YBO-R/SCI YBO-BS YBO-BSB YBN-R/6 YBN-R/6SK YBO-R/6R YBO-R/6RS YBO-R/6RN YBO-R-6PA YBN-R/3(SCI) Standard Base Positive switching short circuit isolator base Sounder base Sounder base with Beacon Standard Base Standard base with schottky diode Relay Base Relay Base latching with schottky diode Relay base non latching Protector alarms base Short circuit isolator base Hochiki Corporation 246 Tsuruma, Machidia, Tokyo 194-8577, Japan Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167 E-mail: [email protected] • Website: www.hochiki.co.jp Certificate No: 117k to EN 54-10: 2002 + A1: 2005 20 Oct 2014 287 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products DRD-E Bases YBN-R/6SK YBN-R/6 YBO-R/6R YBO-R/6RN YBO-R/6PA YBO-R/6RS Conventional Class 1 IR Flame Detector (YBN-R/6SK, YBN-R/6, YBO-R/6R, YBO-R/6RN, YBO-R/6PA, YBO-R/6RS) LPCB Ref. No. 117k/01 Conventional Schottky diode base Conventional standard base Conventional latching relay base Conventional non-latching relay base Conventional 2 wire base Conventional latching relay base with integral Schottky diode Hochiki Europe (UK) Limited Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132 Website: www.hochikieurope.com Certificate No: 928k-(cl-7) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008 Smoke Detectors Certificated Products ROD-E Wireless optical smoke detector (RSM-WDB base) Notes: 1. Meets the requirements of EN 54-5 for Class A1R 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928k/01 Bases: RSM-WDB - Wireless Adaptor Base Certificate No: 928j-(cl-7) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008 Heat Detectors Certificated Products RHD-E Wireless heat detector (RSM-WDB base) Notes: 1. Meets the requirements of EN 54-5 for Class A1R 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928j/01 Base: RSM-WDB - Wireless Adaptor Base 288 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS All Enquiries to: Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0) 1634 260131 • Fax: +44 (0) 1634 260132 Manufacturing at (Certificate Nos 117, 117f, 117g, 117h, 117j) Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167 E-mail: [email protected] • Website: www.hochiki.co.jp Manufacturing at (Certificate Nos 164, 164g, 164m) Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0) 1634 260131 • Fax: +44 (0) 1634 260132 E-mail: sales @hochikieurope.com • Website: www.hochikieurope.com Manufacturing at (Certificate Nos 358, 358c) Hochiki America Corporation, 7051 Village Drive, Buena Park, California 90621, USA Tel: +1 714 522 2246 • Fax: +1 714 522 2268 E-mail: [email protected] • Website: www.hochiki.com Certificate No: 117h to EN 54-7: 2000 Certificate No: 164g to EN 54-7: 2000 + A1: 2002 Certificate No: 358c to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors/Sensors Certificated Products SLV-E(J) ALK-E(J) ALN-E(HFP) ALN-EN ALN-EN(WHT) SLR-E-IS SLK-EN ALK-E(HFP) ALK-EM ALG-ENM 20 Oct 2014 1 Conventional photoelectric smoke detector (YBN-R/4C base) Analogue addressable photoelectric smoke detector (YBN-R/2NA,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Intelligent Analogue Addressable Optical Smoke Detector (YBN-R/3(SCI), YBN-R/3, YBO-R/SCI, YBN-R/2NA, YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Intelligent Analogue Addressable Optical Smoke Detector (YBN-R/3(SCI), YBN-R/3, YBO-R/SCI, YBN-R/2NA, YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings Intelligent Analogue Addressable Optical Smoke Detector (YBN-R/3(SCI), YBN-R/3, YBO-R/SCI, YBN-R/2NA, YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings Conventional photoelectric smoke detector (YBN-R/4IS base) Conventional photoelectric smoke detector (YBF-RL/4H3, YBF-RL/4H5, YBF-RL/4H5H bases) Intelligent analogue addressable optical smoke detector (White) (YBN-R/3(HFP), YBO/R3SCI(HFP), YBO/BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and lower power modes Intelligent analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Intelligent analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes LPCB Ref. No. 117h/01 117h/02 117h/03 117h/04 117h/04 164g/02 164g/03 358c/03 358c/03 358c/04 289 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products SLV-E3 SLV-E3 (WHT) SLV-E3(HFP) SLR-E3N SLR-E3N(BLK) SLR-E3N(WHT) Bases YBO-R/SCI YBO-BS YBO-BSB YBO-R/6R YBO-R/6RS YBO-R/6RN YBO-R/6PA YBN-R/3 YBN-R/2NA YBN-R/6 YBN-R/6SK YBO-BS YBO-BSB YBN-R/3(SCI) YBN-R/3 Conventional optical smoke detector (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) Conventional optical smoke detector(White) (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) Conventional optical smoke detector (White) (YBN-R/6(HFP) bases) Conventional optical smoke detector (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) Conventional optical smoke detector(Black) (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) Conventional optical smoke detector(White) (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) LPCB Ref. No. 358c/05 358c/05 358c/05 358c/06 358c/06 358c/06 Positive switching short circuit isolator base Sounder base Sounder base with Beacon Relay base Relay base latching with schottky diode Relay base non latching Protector alarms base Standard base Standard base Standard base Standard base with schottlky diode Sounder base Sounder base with Beacon Short Circuit Isolator Base Addressable detector base All Enquiries to: Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260131 • Fax: +44 (0)1634 260132 Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j) Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167 E-mail: [email protected] • Website: www.hochiki.co.jp Manufacturing at (Certificate Nos. 164, 164g, 164m) Hochiki Europe (UK) Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (01634 260131 • Fax: +44 (0)1634 260132 E-mail: [email protected] • Website: www.hochikieurope.com Manufacturing at (Certificate Nos. 358, 358c) Hochiki America Corporation, 7051 Village Drive, Buena Park, California 90621, USA Tel: +1 714 522 2246 • Fax: +1 714 522 2268 E-mail: [email protected] • Website: www.hochiki.com Certificate No: 117g to EN 54 Part 5: 2000 290 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Point Heat Detectors/Sensors Certificated Products DCD-1E-IS DFJ-AE3 DFJ-AE3 (HFP) DFJ-CE3 DFJ-CE3 (HFP) DCD-AE3 DCD-AE3 (HFP) DCD-AE3M DFG-60BLKJ DCD-CE3 DCD-CE3(HFP) DCD-CE3M ACB-E ACB-E (HFP) ACB-EW ATJ-E ATJ-E(HFP) ATJ-E(WHT) ATJ-EN ATJ-EN(WHT) Bases: YBN-R/4IS YCA-RL/3H2M YBN-R/6SK YBN-R/6 YBN-R/3 YBO-R/SCI YBO-RSCI/NS YBF-RL/4H3H YBF-RL/4H5H YBN-R/6M YBO-BSB 20 Oct 2014 Class A1 conventional intrinsically safe fixed temperature and rate of rise heat detector (YBN-R/4IS1 base) Class A1S conventional fixed temperature heat detector (YCA-RL/3H2M 1 , YBN-R6 SK 1 , YBN-R/6 1 YBO-R/6R, YBO-R/6RS, YBO-R/6RN and YBO-R/6PA bases) Class A1S conventional fixed temperature heat detector (YBN-R/6(HFP) base) Class CS conventional fixed temperature heat detector (YCA-RL/3H2M 1 , YBN-R6 SK 1 , YBN-R/6 1 YBO-R/6R, YBO-R/6RS, YBO-R/6RN and YBO-R/6PA bases) Class CS conventional fixed temperature heat detector (YBN-R/6(HFP)base) Class A1R conventional rate of rise temperature heat detector (YCA-RL/3H2M 1 , YBN-R6 SK 1 , YBN-R/6 1 YBO-R/6R, YBO-R/6RS, YBO-R/6RN and YBO-R/6PA bases) Class A1R conventional rate of rise temperature heat detector (YBN-R/6 (HFP)base) Conventional Class A1R rate of rise temperature heat detector (YBN-R/6M base) Class A2 conventional fixed temperature water resistant heat detector CDX Class CR conventional rate of rise high temperature heat detector (YCA-RL/3H2M 1 , YBN-R6 SK 1 , YBN-R/6 1 YBO-R/6R, YBO-R/6RS, YBO-R/6RN and YBO-R/6PA bases) Class CR conventional rate of rise high temperature heat detector (YBN-R/6(HFP)base) Conventional Class CR rate of rise high temperature heat detector (YBN-R/6M base) Intelligent Analogue addressable Class P heat detector (YBN-R/3 1 and YBO-R/SCI 1 bases) Note: Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol. Intelligent analogue addressable Class P heat detector (YBN-R/3(HFP) and YBOR/SCI(HFP) bases). Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol. Weather proof Intelligent Analogue addressable Class P heat detector Note: Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol. Intelligent Analogue addressable Class P heat detector (YBN-R/3 1 , YBN-R/3(SCI) 1 ,YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases) Note: Meets requirements of EN 54-5:2000 for classes A1R, BR and CR. Intelligent Analogue addressable Class P heat detector (YBN-R/3 1 , YBN-R/3(SCI) 1 , YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases) Note: Meets requirements of EN 54-5:2000 for classes A1R, BR, CR, A1S, BS and CS. Intelligent Analogue addressable Class P heat detector (YBN-R/3 1 , YBN-R/3(SCI) 1 ,YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases) Note: Meets requirements of EN 54-5:2000 for classes A1R, BR, CR, A1S, BS and CS. Intelligent Analogue addressable Class P heat detector (YBN-R/3 1 , YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases) Note: Meets requirements of EN 54-5:2000 for classes A1R, BR CR, A1S, BS and CS. Intelligent Analogue addressable Class P heat detector (YBN-R/3 1 , YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases) Note: Meets requirements of EN 54-5:2000 for classes A1R, BR, CR, A1S, BS and CS. LPCB Ref. No. 117g/01 117g/02 117g/02 117g/03 117g/03 117g/04 117g/04 117g/04 117g/05 117g/06 117g/06 117g/06 117g/09 117g/09 117g/10 117g/13 117g/13 117g/13 117g/14 117g/14 Conventional Intrinsically Safe Mounting base Addressable base Schottky diode base Standard base Standard base Positive Switching Short circuit isolating base Negative Switching Short circuit isolating base 2 wire common mounting base 2 wire common mounting base Standard Base Base sounder beacon 291 PART 1: SECTION 4.1 COMMERCIAL DETECTORS YBO-BS YBO-R/6PA YBO-R/6R YBO-R/6RS YBO-R/6RN YBN-R/3(SCI) Base sounder Protector alarms base Relay base Relay latching base with Schottky diode Relay base non-latching Short circuit Isolating base All Enquiries to: Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260131 • Fax: +44 (0)1634 260132 Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j) Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167 Certificate No: 117f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 and CEA 4021: 1999 Certificate No: 928m-(cl-7) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003 Multi-criteria Detectors Certificated Products ACA-E ACA-E (HFP) ACC-E ACC-E(HFP) ACC-E(WHT) ACC-EN ACC-EN(WHT) RMD-E 292 Intelligent Analogue addressable multisensor (YBN-R/3 base) Note: Meets EN 54-5 class A1 and B and EN 54: Part 7 at 3.0%/m sensitivity setting in normal and low power mode. Intelligent analogue addressable multisensor (YBN-R/3(HFP) base) Note: Meets EN 54-5 class A1 and B and EN 54: Part 7 at 3.0%/m sensitivity setting in normal and low power mode. Intelligent Analogue addressable multi-criteria detector (YBN-R/31, YBO-R/SCI1, YBO-BS1, YBO-BSB1 and YBN-R/3(SCI) bases) Note: Certificated at the following modes: Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity Mode 2 - Fixed temperature heat detector at class A1 & C Intelligent Analogue addressable multi-criteria detector (YBN-R/3(HFP), YBO-R/SCI, YBO-BS and YBO-BSB bases) Note: Certificated at the following modes: Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity Mode 2 - Fixed temperature heat detector at class A1 & C Intelligent Analogue addressable multi-criteria detector (YBN-R/31, YBO-R/SCI1, YBO-BS1, YBO-BSB1 and YBN-R/3(SCI) bases) Note: Certificated at the following modes: Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity Mode 2 - Fixed temperature heat detector at class A1 & C Intelligent Analogue addressable multi-criteria detector (YBN-R/3, YBO-R/SCI, YBO-BS, YBO-BSB and YBN-R/3(SCI) bases) Note: Certificated at the following modes: Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity Mode 2 - Fixed temperature heat detector at class A1 & C Intelligent Analogue addressable multi-criteria detector (YBN-R/3, YBO-R/SCI, YBO-BS, YBO-BSB and YBN-R/3(SCI) bases) Note:Certificated at the following modes: Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity Mode 2 - Fixed temperature heat detector at class A1 & C Wireless multi-criteria detector (RSM-WDB base) Notes: 1. Meets the requirements of EN 54-5 for Class A1 2. Meets the requirements of EN 54-7 in the normal sensitivity setting LPCB Ref. No. 117f/01 117f/01 117f/02 117f/02 117f/02 117f/03 117f/03 928m/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. 3. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery Bases: YBN-R/3 base YBN-R/3 Standard base YBN-R/2NA base YBO-R/SCI Positive switching short circuit isolator base YBN-R/4IS intrinsically safe mounting base1 YCA-RL/3H2 addressable base YCA-RL/5H2 master addressable base AMU-B2 addressable base AMU-MB master addressable base YBC-RL/4H5 base YBF-RL/3J slave base YBF-RL/4H5 base1 YBK-RL/4H1A base1 YBK-RL/4H2 base1 YCA-RL/3H2M addressable base YBN-R/6SK Schottky diode base YBN-R/6 Standard base YBN-R/4 base1 YBN-R/6M Standard base YBO-BS Sounder base YBO-BSB Sounder base with Beacon YBO-R/5 base1 YBN-R/4M base1 YBO-R/5M base1 YBO-R/6R Relay base YBO-R/6RS Relay base latching with schottky diode YBO-R/6RN Relay base non latching YBO-R/6PA Protector alarms base YBO-RSCI/NS Negative Switching Short circuit isolating base YBF-RL/4H3H 2 wire mounting base YBF-RL/4H5H 2 wire mounting base RSM-WDB - Wireless Adaptor Base YBN-R/3(SCI) Short circuit isolator base 1 Bases manufactured by Hochiki Europe. All other bases manufactured by Hochiki Corporation. denotes detector/base combination is approved in low power mode also. LP All Enquiries to: Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260131 • Fax: +44 (0)1634 260132 Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j) Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167 Certificate No: 117j to EN 54-12: 2002 Beam Detectors Certificated Products SRA-ET SRA-ET (HFP) SPC-E 20 Oct 2014 Optical Beam Smoke Detector Note: 1) Certified at sensitivity settings 30% obscuration Optical Beam Smoke Detector Note: 1) Certified at sensitivity settings 30% obscuration Conventional 4 wire optical beam smoke detector Notes: LPCB Ref. No. 117j/01 117j/01 117j/02 293 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products SPC-ET SPC-ET(HFP) LPCB Ref. No. 1) Approved at sensitivity setting 25% and 50% Conventional 2 wire optical beam smoke detector Notes: 1) Approved at sensitivity setting 25% and 50% 2) Approved for use with SPC-ET2WI interface kit Conventional 2 wire optical bem smoke detector. Notes: 1) Approved at sensitivity setting 25% and 50% 2) Approved for use with SPC-ET2WI interface kit 117j/03 117j/03 All Enquiries to: Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0) 1634 260131 • Fax: +44 (0) 1634 260132 Manufacturing at (Certificate Nos 164, 164g, 164m) Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0) 1634 260131 • Fax: +44 (0) 1634 260132 E-mail: [email protected] • Website: www.hochikieurope.com Certificate No: 164m to EN54-10:2002 Flame Detectors Certificated Products IFD-E IFD-E(IS) IFD-E(EXD) LPCB Ref. No. 164m/01 Conventional IR 3 Flame detector (IFD-MB) Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR 3 Intrinsically Safe Flame Detector (IFD-MB) Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR 3 (Exd) Flameproof Flame Detector (IFD-MB) Note: Meets EN 54-10: 2002 at Class 1 only 164m/02 164m/03 Honeywell Automation (I) Pvt. Ltd 53, 54, 55 Hadapasar Indl. Estate, Hadapsar, Pune-411013, India Tel: +91 020 66780200 • Fax: +91 020 66780172 E-mail: [email protected] • Website: www.honeywell.com Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003 Certificate No: 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003 Multi-criteria Detectors Certificated Products TC840MES-yy TC840MEIS-yy 294 Analogue addressable photo-thermal multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: LPCB Ref. No. 550b/05 550e/02 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Bases: 1450614-007 Standard analogue detector base B501 standard analogue detector base B501AP intelligent detector base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base Certificate No: 550c to EN54-5: 2000 + A1: 2002 Certificate No: 550f to EN54-5: 2000 + A1: 2002 and EN 54-17: 2005 Point Heat Detectors Certificated Products TC808ES1028-yy TC808ES1002-yy TC808EIS1028-yy TC808EIS1002-yy Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Analogue addressable class A1S fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Analogue addressable class A1R rate of rise heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Analogue addressable class A1S fixed temperature heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White LPCB Ref. No. 550c/06 550c/07 550f/01 550f/02 Bases: 14506414-007 Standard analogue detector base B501 standard analogue detector base B501AP intelligent detector base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base Certificate No: 550a to EN54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 550d to EN54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Point Smoke Detectors Certificated Products TC806ES1012-yy TC806EIS1012-yy Analogue addressable optical smoke detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity Analogue addressable optical smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity LPCB Ref. No. 550a/04 550d/01 Bases: 14506414-007 standard analogue detector base B501 standard analogue detector base B501AP intelligent detector base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base 20 Oct 2014 295 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Honeywell Control Systems Limited Honeywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United Kingdom Tel: +44 (0)1344 655609 • Fax: +44 (0)1344 655474 Website: www.honeywell.com Certificate No: 199p-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002 and CEA 4021: 2003 Certificate No: 199aa-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005 Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005 Certificate No: 199t-(cl-1) to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Multi-criteria Detectors Certificated Products TC840MFEIS TC840MEIS TC840MFES TC840MES TC850E1009-yy Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal and IR sensors (B501, B501DG and B524IEFT-1 bases) Notes: 1.) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White LPCB Ref. No. 199aa/01 199aa/02 199p/06 199p/07 199t/01 2.) Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria): LPS1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): Nuisance Environment Applications: Application 0,Alarm Level 4 Application 1,Alarm Level 5 Application 2,Alarm Level 4 or 5 Application 3,Alarm Level 5 Application 4,Alarm Level 5 Application 5,Alarm Level 5 Application 6,Alarm Level 5 Application 7,Alarm Level 5 296 EN54-5 Class A1R, EN54-7, EN54-5 Class A1R LPS1279 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, LPS1279 & CEA 4021 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Bases: B501 B501AP B524IEFT-1 B524HTR B524RTE standard analogue detector base intelligent detector base analogue short circuit isolator base heater base latching relay base Certificate No: 199w to EN 54-12: 2002 & EN 54-17: 2005 Beam Detectors Certificated Products TC847A1004EURIS Ancillaries: RTS151-KEY 6500 - LRK/BEAMLRK 6500 - MMK/BEAMMMK 6500 - SMK/BEAMSMK Analogue optical beam detector with self test facility and short circuit isolator feature Note: 1. Meets the requirements of BS EN54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 LPCB Ref. No. 199w/02 Remote test Station Long Range Kit Multi-Mounting Kit Surface Mounting Kit Certificate No: 199n to EN 54-5: 2000 + A1: 2002 Certificate No: 199n-(cl-1) to EN 54-5: 2000 + A1: 2002 Certificate No: 199ac-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005 Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005 Point Heat Detectors Certificated Products TC808EIS1002 TC808EIS1051 TC808EIS1028 TC808ES1028 TC808ES1051 TC808ES1002 Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Analogue addressable class BS fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Analogue addressable class A1R rate of rise heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Analogue addressable class A1R rate of rise heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Analogue addressable class BS fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Analogue addressable class A1S fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) LPCB Ref. No. 199ac/01 199ac/02 199ac/03 199n/15 199n/16 199n/17 Bases: SIGI-IBS Isolator base SIGA-SB Standard base SIGA-SB4 Standard base with trim skirt SIGA-RB Relay base B501 analogue detector base B501AP intelligent sensor base B501DG analogue deep base B524IEFT analogue short circuit isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base Certificate No: 199m to EN 54-7: 2000 + A1: 2002 Certificate No: 118h to EN 54-7: 2000 Certificate No: 199m-(cl-1) to EN 54-7: 2000 + A1: 2002 Certificate No: 199ab-(cl-1) to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005 Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005 Point Smoke Detectors/Sensors Certificated Products TC846A1005 20 Oct 2014 Analogue addressable laser optical detector (B501, B501DG & B524IEFT bases) LPCB Ref. No. 118h/01 297 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products TC806EIS1012 TC842B1007 AE TC806ES1012 LPCB Ref. No. Note: meets requirements of EN 54 Part 7 at sensitivity settings of 7 to 9 inclusive Analogue addressable optical smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity Intrinsically safe analogue addressable photoelectric smoke detector (B501, B501AP bases) Note: Meets EN54-7: 2000 at High, Normal & Low sensitivity settings Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity 199ab/01 199m/07 199m/10 Bases: B501 Analogue detector base B501DG Analogue deep base B501AP Intelligent detector base B524IEFT Analogue short circuit isolator base B524IEFT-1 Analogue short circuit isolator base B524HTR Heater Base B524RTE Latching relay base SIGI-IBS Isolator base SIGA-SB Standard Base SIGA-SB4 Standard base with trim skirt SIGA-RB Relay base SIGA-RB4 Relay base with trim skirt Honeywell Control Systems Ltd Honeywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United Kingdom Tel: 01344 655609 • Fax: 01344 655474 Website: www.honeywell.com Certificate No: 262s-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA 4021: 2003 Certificate No: 262t-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products XLS-IPHSI XLS-PHSI XLS-ISI XLS-PSI 298 Intelligent analogue addressable thermally enhanced photoelectric and ionisation smoke detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4 & SIGA-AB4G bases) Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases. Intelligent analogue addressable thermally enhanced photoelectric smoke detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4 and SIGA-AB4G bases) Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases. Intelligent analogue addressable ionisation smoke detector SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4 and SIGA-AB4G bases) Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases Intelligent analogue addressable photoelectric smoke detector SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4 and SIGA-AB4G bases) Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2. The SIGA-LED indicator is approved for use with LPCB Ref. No. 262s/01 262s/02 262t/01 262t/02 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. the SIGA-SB and SIGA-SB4 bases Bases: SIGI-IBS SIGA-SB SIGA-SB4 SIGA-RB SIGA-RB4 SIGA-IB SIGA-IB4 SIGA-AB4G Isolator base Standard base Standard base with trim skirt Relay base Relay base with trim skirt Isolator Base Isolator base with 4 inch mounting adaptors Sounder base Accessories: SIGA-LED Indicator Certificate No: 262u-(cl-2) to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products XLS-HRSI Bases: SIGI-IBS SIGA-SB SIGA -SB4 SIGA -RB SIGA -RB4 SIGA-IB SIGA-IB4 SIGA-AB4G Intelligent analogue addressable Class A1 & A2R rate of rise heat detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB, SIGA-IB4 and SIGA-AB4G bases) Notes: 1. The SIGA-LED indicator is also approved for use with the SIGA-SB and SIGA-SB4 bases LPCB Ref. No. 262u/02 Isolator base Standard base Standard base with trim skirt Relay base Relay base with trim skirt Isolator Base Isolator base with 4 inch mounting adaptors Sounder base Accessories: SIGA-LED Indicator Honeywell Life Safety Systems (Novar Systems Ltd) 140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300 E-mail: [email protected] • Website: www.gent.co.uk Certificate No: 524c-(cl-1) to EN 54-20:2006 Aspirating Smoke Detectors Certificated Products LPCB Ref. No. 524c/01 ALL-SPEC ASD Notes: 1. Approval of the detector is conditional upon the following requirements: For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1 HW. The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131. 2. Approved detector configurations (Class A, Class B and Class C): ALL-SPECx (standard version, no bargraph display, 1 alarm, not available for networking) ALL-SPECx-FR (deep freeze version, no bargraph display, 1 alarm, not 20 Oct 2014 299 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. available for networking ) ALL-SPECx-SL (silent version, no bargraph display, 1 alarm, not available for networking) X=detector 1 or 2 The approved detector must incorporate one or two of the following detector modules: ASD-TP-001-L (standard version, sensitivity of 0.015%/m) ASD -TP-001-L-F (deep freeze version, sensitivity of 0.015%/m) ASD -TP-01-L (standard version, sensitivity of 0.10%/m) ASD -TP-01-L-F (deep freeze version, sensitivity of 0.10%/m) ASD -TP-05-L (standard version, sensitivity of 0.50%/m) ASD -TP-05-L-F (deep freeze version, sensitivity of 0.50%/m) X=detector 1 or 2 3. HI-SPEC ASD 524c/03 Notes: 1. Approval of the detector is conditional upon the following requirements: For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1 HW. The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131. 2. Approved detector configurations (Class A, Class B and Class C): HI-SPECx (standard version, bargraph display, 3 alarms, prepared for networking) HI-SPECx-FR (deep freeze version, bargraph display, 3 alarms, prepared for networking) HI-SPECx -SL (silent version, bargraph display, 3 alarms, prepared for networking) 3. The approved detector must incorporate one or two of the following detector modules: ASD-TT-001-L (standard version, sensitivity of 0.015%/m) ASD -TT-001-L-F (deep freeze version, sensitivity of 0.015%/m) ASD -TT-01-L (standard version, sensitivity of 0.10%/m) ASD -TT-01-L-F (deep freeze version, sensitivity of 0.10%/m) ASD -TT-05-L (standard version, sensitivity of 0.50%/m) ASD -TT-05-L-F (deep freeze version, sensitivity of 0.50%/m) COMPACT ASD 524c/04 Notes: 1. Approval of the detector is conditional upon the following requirements: For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1 HW. The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131. 2. Approved detector configurations, sensitivity of 0.50%/m (Class A, Class B and Class C): ASD-CM (version with 2 stages of alarm) ASD-CM2 (version with 2 stages of alarm, ROOM IDENT) Horing LIH Industrial Co Ltd No. 17-6, Ai-Chien Road, Hu-Hsi Village, Yuan-Shan Hsiang (264), Ilan Hsien, Taiwan ROC Tel: +886 2 22487599 • Fax: +886 2 22407752 Certificate No: 506a to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products AHS-871 300 Conventional photoelectric smoke detector (AHMB-L mounting base) LPCB Ref. No. 506a/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products AH-0311-2 AH-0311-3 AH-0311-4 Q01-2 Q01-3 Q01-4 (2 wire) Conventional photoelectric smoke detector (AHMB-031 Base) (3 wire) Conventional photoelectric smoke detector (AHMB-031 Base) (4 wire) Conventional photoelectric smoke detector (AHMB-031 Base) Conventional 2-wire optical smoke detector (AHMB-061-2 and AHMB-071-2 bases ) Conventional 3-wire optical smoke detector with remote (AHMB-061-3 and AHMB-071-3 bases ) Conventional 4-wire optical smoke detector with relay output (AHMB-061-4 and AHMB-071-4 bases) LPCB Ref. No. 506a/02 506a/03 506a/04 506a/05 506a/06 506a/07 Bases: AHMB-031 mounting base AHMB-L mounting base AHMB-061-2 Standard base AHMB-061-3 Standard base AHMB-061-4 Standard base AHMB-071-2 Base Unit AHMB-071-3 Base Unit AHMB-071-4 base Unit Certificate No: 506b to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002 and CEA 4021: 2003 Multi-criteria Detectors Certificated Products AH-0315-2 AH-0315-3 AH-0315-4 Q05-2 Q05-3 Q05-4 (2 wire) Optical smoke and class A2 heat detector (AHMB-031 Base) (3 wire) Optical smoke and class A2 heat detector (AHMB-031 Base) (4 wire) Optical smoke and class A2 heat detector (AHMB-031 Base) Conventional 2-wire optical smoke and class A2 heat detector (AHMB-061-2 and AHMB-071-2 bases) Conventional 3-wire optical smoke and class A2 heat detector with remote LED (AHMB061-3 and AHMB-071-3 bases) Conventional 4-wire optical smoke and class A2 heat detector with relay output (AHMB061-4 and AHMB-071-4 bases) LPCB Ref. No. 506b/01 506b/02 506b/03 506b/04 506b/05 506b/06 Bases: AHMB-031 mounting base AHMB-061-2 Standard base AHMB-061-3 Standard base AHMB-061-4 Standard base AHMB-071-2 Base Unit AHMB-071-3 Base Unit AHMB-071-4 base Unit Certificate No: 506c to EN 54-5: 2000 + A1: 2002 Point Heat Detector Certificated Products AH-0316-2 AH-0316-3 AH-0316-4 Q06-2 Q06-3 Q06-4 (2 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB031 Base) (3 wire) Conventional three wire rate of rise and fixed temperature heat detector (AHMB031 Base) (4 wire) Conventional four wire rate of rise and fixed temperature heat detector (AHMB031 Base) Conventional 2-wire Class A2 heat detector (AHMB-061-2 and AHMB-071-2 bases) Conventional 3-wire Class A2 heat detector with remote LED (AHMB-061-3 and AHMB-071-3 bases) Conventional 4-wire Class A2 heat detector with relay output (AHMB-061-4 and AHMB-071-4 bases) LPCB Ref. No. 506c/01 506c/02 506c/03 506c/04 506c/05 506c/06 Bases: AHMB-031 mounting base AHMB-061-2 Standard base AHMB-061-3 Standard base 20 Oct 2014 301 PART 1: SECTION 4.1 COMMERCIAL DETECTORS AHMB-061-4 Standard base AHMB-071-2 Base Unit AHMB-071-3 Base Unit AHMB-071-4 base Unit Certificate No: 506f to EN 14604: 2005 Smoke Detectors Certificated Products NQ9S LPCB Ref. No. 506f/01 Single Station Smoke Detector INIM Electronics s.r.l. Via Fosso Antico - Loc, Centobuchi, 63033 Monteprandone (AP), Italy Tel: +39 0735 705007 • Fax: +39 0735 704912 E-mail: [email protected] • Website: www.inim.biz Certificate No: 991d to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 991c to EN 54-7: 2000 + A1:2002 + A2:2006 Smoke Detectors Certificated Products ID100 ED100 LPCB Ref. No. 991c/01 Conventional optical smoke detector (EB0010 and EB0020 bases). Note: 1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities. Intelligent analogue addressable optical smoke detector with short circuit isolator (EB0010 and EB0020 bases). Note: 1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities. 991d/01 Bases: EB0010 Standard base EB0020 Relay base Certificate No: 991f to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 991e to EN 54-5: 2000 + A1:2002 Heat Detectors Certificated Products ID200 ED200 Conventional class P heat detector (EB0010 and EB0020 bases). Note: 1) Meets the requirements of EN54-5:2000 at class A1R & class B. Intelligent analogue addressable class P heat detector with short circuit isolator (EB0010 and EB0020 bases). Note: 1) Meets the requirements of EN54-5:2000 at class A1R & class B. LPCB Ref. No. 991e/01 991f/01 Bases: EB0010 Standard base EB0020 Relay base Certificate No: 991b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003 and EN 54-17: 2005 Certificate No: 991a to EN 54-5: 2000 + A1:2002, EN 54-7: 2000 + A1:2002 + A2:2006 and CEA4021: 2003 302 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Multi-Criteria Detectors Certificated Products ID300 ED300 Conventional multi-criteria detector (EB0010 and EB0020 bases). Note: 1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities. 2) Meets the requirements of EN 54-5:2000 at class A1R & class B. Intelligent analogue addressable multi-criteria detector with short circuit isolator (EB0010 and EB0020 bases). Note: 1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities. 2) Meets the requirements of EN 54-5:2000 at class A1R & class B. LPCB Ref. No. 991a/01 991b/01 Bases: EB0010 Standard base EB0020 Relay base Intelligent Safety & Security Technology Ltd. 6-7 Ludgate Square,, London EC4M 7AS, United Kingdom Tel: +44 845 116 2945 E-mail: [email protected] • Website: www.isst-uk.com Certificate No: 512a-(cl-6) to EN54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products CS-01 Conventional 2 wire photoelectric smoke detector with remote LED output (CB-D2 base) LPCB Ref. No. 512a/02 Base: CB-D2 4-wire detector base Certificate No: 512b-(cl-3) to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA4021: 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products CSH-01 Conventional 2 wire photoelectric smoke and heat detector with remote LED output (CBD2 base) LPCB Ref. No. 512b/02 Base: CB-D2 4-wire detector base Certificate No: 512d-(cl-6) to EN54-5: 2000 + A1: 2002 Heat Detectors Certificated Products CH-01 Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (CB-D2 base) LPCB Ref. No. 512d/04 Base: CB-D2 4-wire detector base 20 Oct 2014 303 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Kidde Products Ltd Thame Park Road, Thame, Oxfordshire OX9 3RT, United Kingdom Tel: +44 (0)1844 265003 • Fax: +44 (0)1844 265156 E-mail: [email protected] • Website: www.kfp.co.uk Certificate No: 404c to EN54-20: 2006 Aspirating Smoke Detectors Certificated Products Senator 25 Senator 100 Senator 200 Senator 200 Senator 200 High sensitivity aspirating smoke detector Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. - The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.31%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating smoke detector Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. - The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating smoke standard detector (Senator 200 Stand Alone Command Module Ancillary) Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. - The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating smoke command module detector Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. - The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating minimum display version smoke detector (Senator 200 Stand Alone Command Module Ancillary) Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. - The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. LPCB Ref. No. 404c/01 404c/02 404c/03 404c/04 404c/05 Ancillaries: Senator 200 Stand Alone Command Module 304 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Kidde Products Ltd, trading as AirSense Technology Unit 2, Dawdon Business Park, Blair Way, Seaham, Country Durham SR7 7PP, United Kingdom Tel: +44(0)191-513 6100 • Fax: +44(0)191-513 6102 E-mail: [email protected] • Website: www.kfp.co.uk Certificate No: 404c to EN 54-20: 2006 Certificated Products Senator Nano High sensitivity aspirating smoke detector Notes: 1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4. 2. The approval of the detector is conditional upon the following requirements: Design, installation and commissioning are performed in accordance with the system design manual and instructions. 3. The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.80%/m, 1.66%/m and 7.54%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. LPCB Ref. No. 404c/06 Certificate No: 404c to EN54-20: 2006 Certificated Products Stratos Micra 25 Stratos Micra 100 Stratos HSSD 2 Stratos HSSD 2 20 Oct 2014 High sensitivity aspirating smoke detector Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. 3) The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.31%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating smoke detector Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. 3) The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating smoke standard detector (Stratos HSSD 2 Stand Alone Command Module Ancillary) Notes: 1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4. 2. The approval of the detector is conditional upon the following requirements: Design, installation and commissioning are performed in accordance with the system design manual and instructions. The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively.. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating command module smoke detector Notes: 1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4. 2. The approval of the detector is conditional upon the following requirements: Design, installation and commissioning are performed in accordance with the system design manual and instructions. The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively.. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. LPCB Ref. No. 404c/01 404c/02 404c/03 404c/04 305 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products Stratos HSSD 2 High sensitivity aspirating minimum display version smoke detector (Stratos HSSD 2 Stand Alone Command Module Ancillary) Notes: 1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4. 2. The approval of the detector is conditional upon the following requirements: Design, installation and commissioning are performed in accordance with the system design manual and instructions. The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively.. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating standard smoke detector 1, 2, 3 Notes: 1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4. 2. The approval of the detector is conditional upon the following requirements: Design, installation and commissioning are performed in accordance with the system design manual and instructions. The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.80%/m, 1.66%/m and 7.54%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. Stratos Nano LPCB Ref. No. 404c/05 404c/06 Ancillaries: Stratos HSSD 2 Stand Alone Command Module Labor Strauss Sicherungsanlagenbau GmbH Wiegelestrasse 36, A-1231 Vienna, Austria Tel: +43 1 52114-44 • Fax: +43 1 52114-27 E-mail: [email protected] • Website: www.lst.at Certificate No: 928e-(cl-11) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 928b-(cl-8) to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 Smoke Detectors Certificated Products FI750/O Analogue addressable photoelectric smoke detector with short-circuit isolator (F1750/B base) Notes: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low FC650/O Conventional Photo Detector (FC600/B, FC600/BR and FC600/BRD bases) Bases FC600/B FC600/BR FC600/BRD F1750/B LPCB Ref. No. 928b/02 928e/02 Universal adaptor base Universal adaptor base with resistor Universal adaptor base with resistor and Schottky diode Low profile adaptor base Certificate No: 928a-(cl-8) to EN 54-5: 2000 + A1: 2002, EN 54-17: 2005 Point Heat Detector Certificated Products FI750/T Base FI750/B 306 Analogue addressable Class P heat detector with short-circuit isolator (F1750/B base) Note:1. Meets the requirements of EN 54-5 for Class A1R, Class B and Class BS LPCB Ref. No. 928a/02 Low profile adaptor base 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 928d-(cl-11) to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products FC650/TDIFF/57 Conventional Class A1R Thermal Detector (FC600/B, FC600/BR and FC600/BRD bases) Conventional Class B Thermal Detector (FC600/B, FC600/BR and FC600/BRD bases) FC650/TMAX/78 Bases FC600/B FC600/BR FC600/BRD LPCB Ref. No. 928d/02 928d/02 Universal adaptor base Universal adaptor base with resistor Universal adaptor base with resistor and Schottky diode Certificate No: 928c-(cl-8) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005, CEA 4021: 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products FI750/OT Base FI750/B Addressable multi-criteria detector with short-circuit isolator (F1750/B base) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No. 928c/02 Low profile adaptor base Lichfield Fire & Safety Equipment Co. Ltd (LIFECO) Unit 8, Calibre Industrial Park, Laches Close, Four Ashes, Wolverhampton WV10 7DZ, United Kingdom Tel: +44 (0) 1902 798 706 • Fax: +44 (0) 1902 798 679 E-mail: [email protected] • Website: www.lifeco-uk.com Certificate No: 506a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Photoelectric Smoke Detectors Certificated Products LF-PE-4100 LF-PE-4100 Conventional photoelectric smoke detector (AHMB-L base) LPCB Ref. No. 506a/01 Bases: AHMB-L mounting base Certificate No: 506c-(cl-1) to EN 54-5: 2000 + A1: 2002 20 Oct 2014 307 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Point Heat Detectors Certificated Products LFHD60 (2 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB031 base) LPCB Ref. No. 506c/01 Bases: AHMB-031 mounting base Mavili Elektronik Ticaret Ve Sanayi A.S. Bostanci Dudullu Yolu, Kutup Sok, No. 29 Y Dudullu - Umraniye, Istanbul TR 34775, Turkey Tel: +90 216 4664 505 • Fax: +90 216 4664 510 E-mail: [email protected] • Website: www.mavigard.com Certificate No: 926a to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products MG-9100 LPCB Ref. No. 926a/01 Intelligent analogue addressable system photoelectric smoke detector (MG-3510 base) Bases: MG-3510 standard mounting base Certificate No: 926b to EN 54-5: 2000 + A1: 2002 Point Heat Detectors Certificated Products MG-9300 LPCB Ref. No. 926b/01 Intelligent analogue addressable system class A1R rate of rise heat detector (MG-3510 base) Bases: MG-3510 standard mounting base Certificate No: 926c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Multi-criteria Detectors Certificated Products MG-9400 Intelligent analogue addressable system class A1R multisensor detector (MG-3510 base) LPCB Ref. No. 926c/01 Bases: MG-3510 standard mounting base Morley-IAS Fire Systems By Honeywell Honeywell Fire Systems, BSEL Tech Park, Floor 6,Sector 30A, Opposite Vshi Station, Vashi, New Mumbai, India Tel: +91 022 67122427 • Fax: +91 022 67122422 E-mail: [email protected] • Website: www.myhoneywell.com Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003 Certificate No: 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003 308 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Multi-criteria Detectors Certificated Products MI-PTSE MI-PTIR-S2-yy MI-PTSE-S2-yy MI-PTIR-S2I-yy MI-PTSE-S2I-yy Analogue optical/thermal smoke & heat detector (MI-B501 base) Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1 to 5 2) Meets the requirements of EN 54-5:2000 at Class A1R Analogue addressable photo-thermal-IR multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal-IR multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R LPCB Ref. No. 550b/03 550b/04 550b/05 550e/01 550e/02 Bases: MI-B501 Standard analogue detector base B501 standard analogue detector base B501AP intelligent detector base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base Certificate No: 550c to EN 54-5: 2000 + A1: 2002 Certificate No: 550f to EN54-5: 2000 + A1: 2002 and EN 54-17: 2005 Point Heat Detectors Certificated Products MI-FHSE MI-RHSE MI-RHSE-S2-yy MI-FHSE-S2-yy MI-RHSE-S2I-yy MI-FHSE-S2I-yy 20 Oct 2014 Analogue addressable Class A1S fixed temperature heat detector (MI-B501 base) Analogue addressable Class A1R high temperature rate of rise heat detector (MI-B501 base) Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Analogue addressable class A1S fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Analogue addressable class A1R rate of rise heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Analogue addressable class A1S fixed temperature heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: LPCB Ref. No. 550c/04 550c/05 550c/06 550c/07 550f/01 550f/02 309 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Bases: MI-B501 Standard analogue detector base B501 standard analogue detector base B501AP intelligent detector base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 550d to EN54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Point Smoke Detectors Certificated Products MI-PSE MI-PSE-S2-yy MI-PSE-S2I-yy LPCB Ref. No. 550a/03 Analogue addressable optical smoke detector (MI-B501 base) Note: Meets EN 54-7 with low, medium and high sensitivity settings Analogue addressable optical smoke detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity Analogue addressable optical smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity 550a/04 550d/01 Bases: MI-B501 standard analogue detector base B501 standard analogue detector base B501AP intelligent detector base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base Morley-IAS Fire Systems by Honeywell (Pittway Systems Technology Group (Europe) Ltd) Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888 E-mail: [email protected] • Website: www.morley-ias.co.uk Certificate No: 199n to EN 54-5: 2000 + A1: 2002 Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005 Point Heat Detectors Certificated Products MI-FHSE-S2I MI-HTSE-S2I MI-RHSE-S2I HRZ-1005T HRZ-1004T HRZ-1005 MI-RHSE-S2 310 Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Analogue addressable class BS fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Analogue addressable class A1R rate of rise heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Class A2S conventional fixed temperature heat detector (HRZ-1000BSD base) Class BS conventional fixed temperature heat detector (HRZ-1000BSD base) Class A1R conventional rate of rise heat detector (HRZ-1000BSD base) Analogue addressable class A1R rate of rise heat sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) LPCB Ref. No. 199ac/01 199ac/02 199ac/03 199n/10 199n/11 199n/12 199n/15 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products MI-HTSE-S2 MI-FHSE-S2 Analogue addressable class BS fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Analogue addressable class A1S fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) LPCB Ref. No. 199n/16 199n/17 Bases: B501 standard analogue detector base B501DG analogue deep base B524IEFT analogue short circuit isolator base B501AP intelligent sensor base B524IEFT-1 short circuit isolator B524HTR heater base B524RTE latching relay base HRZ-1000BSD standard base with Schottky diode Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005 Multi-criteria Detectors Certificated Products MI-PTIR-S2I MI-PTSE-S2I HRZ-1002 MI-PTIR-S2 MI-PTSE-S2 Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Conventional photo thermal detector (HRZ-1000BSD base) Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT1, B524HTR and B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R LPCB Ref. No. 199aa/01 199aa/02 199p/04 199p/06 199p/07 Bases: B501 standard analogue detector base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue short circuit isolator base B524IEFT-1 analogue sensor short circuit isolator base B524HTR heater base B524RTE latching relay base HRZ-1000BSD standard base with Schottky diode Certificate No: 199m to EN 54-7: 2000 + A1: 2002 Certificate No: 118h to EN 54-7: 2000 Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005 Point Smoke Detectors Certificated Products MI-LZR MI-PSE-S2I 20 Oct 2014 Analogue addressable photoelectric laser smoke detector (B501, B501DG and B524IEFT bases) Meets the requirements of EN 54-7 at sensitivity settings of 7 to 9 inclusive.Analogue addressable optical smoke sensor with short circuit isolator (B501AP, LPCB Ref. No. 118h/01 199ab/01 311 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products HRZ-1003 MI-PSE-S2 LPCB Ref. No. B524HTR and B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity Conventional photoelectric detector (HRZ-1000BSD base) Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity 199m/05 199m/10 Bases: B501 analogue detector base B501DG analogue deep base B524IEFT analogue short circuit isolator base B501AP intelligent sensor base B524IEFT-1 short circuit isolator base B524HTR heater base B524RTE latching relay base HRZ-1000BSD standard base with Schottky diode Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005 Beam Detectors Certificated Products MI-LPB2-S2I LPCB Ref. No. 199w/01 Analogue optical beam detector with short circuit isolator feature Note: 1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 Ancillaries: RTS151-KEY 6500 - LRK/BEAMLRK 6500 - MMK/BEAMMMK 6500 - SMK/BEAMSMK Remote test Station Long Range Kit Multi-Mounting Kit Surface Mounting Kit Certificate No: 199ae to EN54-17: 2005 & EN54-20: 2006 Aspirating Smoke Detectors Certificated Products MI-FL2011EI MI-FL2012EI MI-FL2022EI 312 Analogue addressable single channel loop-based aspirating detector (B501AP base) Notes: 1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by a power supply complying with EN54-4. 2. The approval of the detector is conditional upon the following requirements: System design, installation and commissioning shall be performed in accordance with the FAAST Advanced set-up and control guide (I56-3888-000). 3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeIQLT software (version 1.2.9). Analogue addressable single channel loop-based aspirating detector, dual sensors (B501AP base) Notes: 1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by a power supply complying with EN54-4. 2. The approval of the detector is conditional upon the following requirements: System design, installation and commissioning shall be performed in accordance with the FAAST Advanced set-up and control guide (I56-3888-000). 3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeIQLT software 1.2.9). Analogue addressable dual channel loop-based aspirating detector, dual sensors (B501AP base) Notes: 1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by a power supply complying with EN54-4. 2. The approval of the detector is conditional upon the following requirements: System design, installation and commissioning shall be performed in accordance with the FAAST Advanced set-up and control guide (I56-3888-000). LPCB Ref. No. 199ae/01 199ae/02 199ae/03 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. 3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeIQLT software 1.2.9). Base: B501AP intelligent sensor base Multron Systems Pte Ltd 217 Kallang Bahru, Multron Building, Singapore 339 347, Singapore Tel: +65 6743 2555 / 6395 6868 • Fax: +65 6743 2777 / 6395 6869 E-mail: [email protected] • Website: www.multron.com Certificate No: 548c-(cl-6) to EN 54-5: 2000 + A1: 2002 Certificate No: 1148a to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products DET-C632 DET-C103 DET-A103 Bases: DZ-03 DB-6 Conventional rate of rise & fixed temperature heat detectorstandard base) Note: Meets the requirements of EN 54-5 at Class A2R Conventional Class A1R heat detector (DZ-03 base) Intelligent Class A1R heat detector (DZ-03 base) LPCB Ref. No. 1148a/01 548c/01 548c/02 Standard detector base Standard detector base Certificate No: 548d-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 1148b to EN 54-7:2001 + A1: 2002 + A2: 2006 Photoelectric Smoke Detectors Certificated Products DET-C631 DET-C102 DET-A102 Bases: DZ-03 DB-6 Conventional optical smoke detector (DB-6 Standard base) Note: Meets the requirements of EN 54-7 in the normal sensitivity setting. Conventional Photoelectric Smoke Detector (DZ-03 base) Intelligent Photoelectric Smoke Detector (DZ-03 base) LPCB Ref. No. 1148b/01 548d/01 548d/02 Standard detector base Standard detector base Certificate No: 548k-(cl-6) to EN 54-12: 2002 Beam Detectors Certificated Products DET-105RB 20 Oct 2014 Intelligent Optical Beam Detector Notes: 1: Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 1.61 dBLevel 2 2.31dB LPCB Ref. No. 548k/01 313 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Nitin Ventures FZE P.O. Box 262294, Jebel Ali Free Zone, Dubai, United Arab Emirates Tel: +97 148865858/859 • Fax: +97 148865800 E-mail: [email protected] • Website: www.nitinfire.com Certificate No: 010h-(cl-1) to EN 54-7: 2000 + A1: 2002, EN 54-5: 2000 + A1: 2002, CEA 4021: 2003 Multi-Criteria Detectors Certificated Products NV-I-MS Analogue addressable multisensor detector (NV-IA-SB mounting base) Notes: 1) Certificated at the following settings: Mode 1 - High sensitivity smoke detector with standard heat enhancement Mode 2 - Smoke detection only Mode 3 - Medium sensitivity smoke detector with standard heat enhancement Mode 4 - Low sensitivity smoke detector with high heat enhancement Mode 5 - Class A1 heat detector Also approved in conventional alarm modes 1, 2, 3, 4 and 5. LPCB Ref. No. 010h/01 Bases: NV-IA-SB Mounting Base Certificate No: 010p-(cl-1) to EN 54-5: 2000 + A1: 2002 Point Heat Detectors Certificated Products NV-I-H NV-C-H-A1R NV-C-H-CS LPCB Ref. No. 010p/03 Analogue addressable heat detector (NV-IA-SB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 Class A1R in mode 1 and in conventional mode Class A2 in mode 2 and in conventional mode Class A2S in mode 3 and in conventional mode Class CR in mode 4 and in conventional mode Class CS in mode 5 and in conventional mode. Conventional class A1R heat detector - flashing LED (NV-C-SB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 - Class A1R Series 65 Conventional Class CS heat detector Flashing LED (NV-C-SB mounting base) Meets the requirements of EN54: Part 5 - Class CS 010p/05 010p/14 Bases: NV-IA-SB mounting base NV-C-SB mounting base Certificate No: 010q-(cl-1) to EN 54-7: 2000 + A1: 2002 Point Smoke Detectors Certificated Products NV-I-I NV-I-O NV-C-I NV-C-O Analogue addressable ionisation smoke detector (NV-IA-SB mounting base) Notes: 1) Meets the requirements of EN54-7: 2000 in modes 1,2,3,4 and 5 in conventional mode Analogue addressable optical smoke detector (NV-IA-SB mounting base) Notes: 1) Meets the requirements of EN54-7:2000 in modes 1,2,3 4 and 5 in conventional mode Conventional ionisation smoke detector - flashing LED (NV-C-SB mounting base) Conventional optical smoke detector- flashing LED (NV-C-SB mounting base) LPCB Ref. No. 010q/02 010q/03 010q/05 010q/11 Bases: NV-IA-SB mounting base NV-C-SB mounting base 314 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Nittan Europe Limited Hipley Street, Old Woking, Surrey GU22 9LQ, United Kingdom Tel: +44 (0)1483 769555/8 • Fax: +44 (0)1483 756686 E-mail: [email protected] • Website: www.nittan.co.uk Certificate No: 041f to EN54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 842a-(cl-1) to EN-54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 755a-(cl-1) to EN54-7: 2000 + A1: 2002 Point Smoke Detectors Certificated Products EV-P EVC-P EVC-DP EVC-P ST-P-OM ST-PY-AS EV-P Analogue addressable optical smoke detector (UB-4,UB-4-EV,UB-4-SD and STB-4SEEV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only. EVC-P Conventional optical smoke detector (STB-4-SE-24VR, STB-4SE, UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases) Conventional Dual Optical Smoke Detector (STB-4, STB-4SD, STB-4SE, STB-4SE-24VR, UB-4 and UB-5 bases) Conventional optical smoke detector (STB-4-SE24VR, STB-4-SE ,STB-4 , UB-4 and UB-4SD bases) Conventional optical smoke detector (STB-4-SE24VR, STB-4-SE ,STB-4, UB-4 , UB-4R470 and UB-4SDR470 bases) Analogue addressable photoelectric smoke detector (STB-4-SE ,STB-4 and UB-4 bases) Analogue addressable photoelectric smoke detector ,STB-4-SE-EV and UB4-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only. LPCB Ref. No. 041f/01 041f/03 755a/01 842a/01 842a/02 842a/03 842a/04 Bases STB-4 Standard mounting base STB-4SE-EV mounting base STB-4SE Standard deep mounting base STB-4SD Schottky diode mounting base STB-4-SE-24VR Relay mounting base UB-4 Universal mounting base 4 terminal UB-5 Universal mounting base 5 terminal UB-4-EV Universal base UB-4SD Universal base with Shottky diode Certificate No: 041h to EN 54-5: 2000 + A1: 2002 Point Heat Detectors Certificated Products EV-H-A1R EV-H-CS EVC-H-A2S EVC-H-CS Analogue addressable Class A1R heat detector (UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases) Analogue addressable Class CS heat detector and STB-4SE-EV bases) Conventional Class A2S heat detector (UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases) Conventional Class CS heat detector and STB-4SE-EV bases) LPCB Ref. No. 041h/01 041h/02 041h/03 041h/04 Bases UB-4 Universal base UB-4-EV Universal base UB-4SD Universal base with Shottky diode STB-4SE-EV mounting base Certificate No: 041g to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1:2002 + A2: 2006 and CEA4021: 1999 20 Oct 2014 315 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Multi-criteria Detectors Certificated Products EV-PH LPCB Ref. No. 041g/01 Analogue addressable optical smoke / class A1R heat detector (UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings. Bases UB-4 Universal base UB-4-EV Universal base UB-4SD Universal base with Shottky diode STB-4SE-EV mounting base Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd) Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888 E-mail: [email protected] • Website: www.notifierfiresystems.co.uk Certificate No: 199m to EN 54-7: 2000 + A1: 2002 Certificate No: 118h to EN 54-7: 2000 + A1: 2002 Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005 Point Smoke Detectors Certificated Products FSL-751E NFXI-OPT SD-851E IDX-751 AE NFX-OPT LPCB Ref. No. 118h/01 Analogue addressable photoelectric laser smoke detector (B501, B501DG & B5241EFT bases) Note: meets the requirements of EN 54:Part 7 at sensitivity settings of 7 to 9 inclusive. Analogue addressable optical smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity Conventional photoelectric smoke detector (B401 base) Intrinsically safe analogue addressable photoelectric smoke detector (B501, B501AP bases) Note: Meets EN54-7: 2000 at High, Normal & Low sensitivity settings Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity 199ab/01 199m/03 199m/07 199m/10 Bases: B501 base B401 base B501DG deep base B5241EFT short circuit isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base B501AP Intelligent detector base Certificate No: 199n to EN 54-5: 2000 + A1: 2002 Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005 Point Heat Detectors Certificated Products NFXI-TFIX58 NFXI-TFIX78 NFXI-TDIFF FD-851RE FD-851HTE NFX-TDIFF NFX-TFIX78 316 Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Analogue addressable class BS fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Analogue addressable class A1R rate of rise heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Conventional Class A1R rate of rise heat detector (B401 base) Conventional Class BS heat detector (B401 base) Analogue addressable class A1R rate of rise heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Analogue addressable class BS fixed temperature heat sensor (B501AP, B501, LPCB Ref. No. 199ac/01 199ac/02 199ac/03 199n/07 199n/08 199n/15 199n/16 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products NFX-TFIX58 LPCB Ref. No. B524IEFT-1, B524HTR & B524RTE bases) Analogue addressable class A1S fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) 199n/17 Bases: B501 base B401 base B401R standard base with resistor B401RSD standard base with resistor and schottky diode B401SD standard base with schottky diode B401DG deep base B501AP intelligent sensor base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005 Multi-criteria Detectors Certificated Products NFXI-SMT3 NFXI-SMT2 SD-851TE NFX-SMT3 NFX-SMT2 IRX-751CTEM Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Conventional photoelectric/thermal detector (B401 base) Note: Meets the requirements of EN54-7: 2000 at "High", 'Medium' and 'Low' sensitivity settings Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT1, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal and IR sensors (B501, B501DG and B524IEFT-1 bases) Note: Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria): EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R Nuisance Environment Applications: Application 0, Alarm Level 4 Application 1, Alarm Level 5 Application 2, Alarm Level 4 or 5 Application 3, Alarm Level 5 Application 4, Alarm Level 5 Application 5, Alarm Level 5 Application 6, Alarm Level 5 LPCB Ref. No. 199aa/01 199aa/02 199p/03 199p/06 199p/07 199t/01 EN54-7, LPS1279 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 Bases: B501 base B401 base B501DG deep base 20 Oct 2014 317 PART 1: SECTION 4.1 COMMERCIAL DETECTORS B524IEFT-1 analogue short circuit isolator base B501AP intelligent sensor base B524HTR heater base B524RTE latching relay base Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005 Beam Detectors Certificated Products NFXI-BEAM NFXI-BEAM-T Ancillaries: RTS151-KEY 6500 - LRK/BEAMLRK 6500 - MMK/BEAMMMK 6500 - SMK/BEAMSMK LPCB Ref. No. 199w/01 Analogue optical beam detector with short circuit isolator feature. Note: 1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 Analogue optical beam detector with self test facility and short circuit isolator feature. Note: 1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 199w/02 Remote test Station Long Range Kit Multi-Mounting Kit Surface Mounting Kit Certificate No: 199af-(cl-1) to EN54-17: 2005 & EN54-20: 2006 Aspirating Smoke Detectors Certificated Products NFXI-ASD11 NFXI-ASD12 NFXI-ASD22 Base: B501AP 318 Analogue addressable single channel loop-based aspirating detector Notes: 1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by a power supply complying with EN54-4. 2. The approval of the detector is conditional upon the following requirements: System design, installation and commissioning shall be performed in accordance with the FAAST Advanced set-up and control guide (I56-3888-000). 3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeIQLT software (version 1.2.9). Analogue addressable single channel loop-based aspirating detector dual sensors Notes: 1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by a power supply complying with EN54-4. 2. The approval of the detector is conditional upon the following requirements: System design, installation and commissioning shall be performed in accordance with the FAAST Advanced set-up and control guide (I56-3888-000). 3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeIQLT software (version 1.2.9). Analogue addressable dual channel loop-based aspirating detector dual sensors Notes: 1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by a power supply complying with EN54-4. 2. The approval of the detector is conditional upon the following requirements: System design, installation and commissioning shall be performed in accordance with the FAAST Advanced set-up and control guide (I56-3888-000). 3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeIQLT software (version 1.2.9). LPCB Ref. No. 199af/01 199af/02 199af/03 intelligent sensor base 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Notifier Fire Systems India Honeywell Fire Systems, BSEL Tech Park, Floor 6, 603, Sector 30A, opposite Vashi Station, Vashi, New Mumbia, India Tel: +91 022 67122427 • Fax: +91 02267122422 E-mail: [email protected] • Website: www.myhoneywell.com Certificate No: 550b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003 Certificate No: 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003 Multi-criteria Detectors Certificated Products SDX-751TEM NFX-SMT2-yy NFXI-SMT2-yy Analogue optical/thermal smoke & heat detector (B501, B501DG and B5241EFT-1 bases) Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1 to 5 2) Meets the requirements of EN 54-5:2000 at Class A1R Analogue addressable photo-thermal multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R LPCB Ref. No. 550b/03 550b/05 550e/02 Bases: B501 Standard base B501DG Deep analogue detector base B5242EFT-1 Short circuit islolator base B501AP intelligent detector base B524HTR heater base B524RTE latching relay base Certificate No: 550c to EN 54-5: 2000 + A1: 2002 Certificate No: 550f to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Point Heat Detectors Certificated Products FDX-551EM FDX-551REM NFX-TDIFF-yy NFX-TFIX58-yy NFXI-TDIFF-yy NFXI-TFIX58-yy 20 Oct 2014 Analogue addressable Class A1S fixed temperature heat detector (B501, B501DG and B5241EFT-1 bases) Analogue addressable Class A1R high temperature rate of rise heat detector (B501, B501DG and B5241EFT-1 bases) Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Analogue addressable class A1S fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Analogue addressable class A1R rate of rise heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Analogue addressable class A1S fixed temperature heat detector with short circuit LPCB Ref. No. 550c/04 550c/05 550c/06 550c/07 550f/01 550f/02 319 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. isolator (B501AP, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Bases: B501 Standard base B501DG Deep analogue detector base B542IEFT-1 Short circuit islolator base B501AP intelligent detector base B524HTR heater base B524RTE latching relay base Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 550d to EN54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Point Smoke Detectors Certificated Products SDX-751EM NFX-OPT-yy NFXI-OPT-yy Analogue addressable optical smoke detector (B501, B501DG and B5241EFT-1 bases) Notes: 1) Meets EN 54-7 with low, medium and high sensitivity settings Analogue addressable optical smoke detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity Analogue addressable optical smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity LPCB Ref. No. 550a/03 550a/04 550d/01 Bases: B501 standard analogue detector base B501DG deep analogue detector base B5241EFT-1 analogue short circuit isolator base B501AP intelligent detector base B524HTR heater base B524RTE latching relay base Olympia Electronics S.A. Kolindros Pierias, 60061, Greece Tel: (+30) 2353051200 • Fax: (+30 )2353051486 E-mail: [email protected] • Website: www.olympia-electronics.gr Certificate No: 1010b to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products BSR-6055/A BS-655 Analogue addressable optical smoke detector (BSR-6055/A base) Note: 1. Meets the requirements of EN 54-7: 2000 at sensitivity setting 0.120dB/m Conventional optical smoke detector (BS-655 base) LPCB Ref. No. 1010b/01 1010b/02 Bases BS-655 Base BSR-6055/A Base 320 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Orient Corporation Pte. Ltd. Block 3018, Bedok North Street 5, #05-51, Eastlink Light Industrial Building 486132, Singapore Tel: (+65) 6242 5489 • Fax: (+65) 6241 2291 E-mail: [email protected] Certificate No: 506a-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products OCI 60041 Base OCI 60041-MPB (2 wire) Conventional photoelectric smoke detector (OCI 60041-MPB base) LPCB Ref. No. 506a/02 Mounting Base Certificate No: 506b-(cl-3) to EN 54-7: 2000 + A1: 20002 + A2: 2006, EN 54-5: 2000 + A1: 2002 & CEA 4021: 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products OCI 60042 Base OCI 60041-MPB (2 Wire) Optical smoke and class A2 heat detector (OCI 60041-MPB base) Note:1. Meets the requirements of EN54-5 for class A2 LPCB Ref. No. 506b/01 Mounting Base Certificate No: 506c-(cl-4) to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products OCI 60043 Base OCI 60041-MPB (2 Wire) Conventional Class A2 rate of rise and fixed temperature heat detector (OCI 60041-MPB base) Note:1. Meets the requirements of EN54-5 for class A2 LPCB Ref. No. 506c/01 Mounting base Panasonic Corporation 1668, Fujikata, Tsu-shi, Mie-ken, Japan Tel: +46 40 697 70 00 • Fax: +46 40 697 70 99 E-mail: [email protected] • Website: http://pesn.panasonic.se Certificate No: 1012a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products Type 2840 Base: Type 2843 Intrinsically safe analogue addressable photoelectric smoke detector (Type 2843 base) LPCB Ref. No. 1012a/01 Intrinsically safe backbox Certificate No: 1012b-(cl-1) to EN 54-5: 2000 + A1: 2002 20 Oct 2014 321 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Heat Detectors Certificated Products Type 2841 Base: Type 2843 Intrinsically safe analogue addressable class P heat detector (Type 2843 base) Note: Meets EN54 Part 5 for classes A1, A2S & BS LPCB Ref. No. 1012b/01 Intrinsically safe backbox Pelco Finland Oy Sokerilinnantie 11C, 02600, Espoo, Finland Tel: +358 10 446 511 • Fax: +358 10 446 5103 E-mail: [email protected] • Website: www.pelco.com/nordic Certificate No: 199u to EN 54-12: 2002 Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005 Beam Detectors Certificated Products EB-6500R EB-6500RS EB-6500A EB-6500SA Ancillaries: RTS151-KEY 6500 - LRK/BEAMLRK 6500 - MMK/BEAMMMK 6500 - SMK/BEAMSMK Conventional optical beam detector Note: 1. Meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2 Conventional optical beam detector with self test facility Note: 1. Meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2 Analogue optical beam detector with short circuit isolator feature Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 Analogue optical beam detector with self test facility and short circuit isolator feature Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 LPCB Ref. No. 199u/01 199u/02 199w/01 199w/02 Remote test Station Long Range Kit Multi-Mounting Kit Surface Mounting Kit Certificate No: 199m to EN 54-7: 2000 + A1: 2002 Smoke Detectors Certificated Products ED2351E Conventional photoelectric detector (B401, B401DG, B401R, B401SD and B401RSD bases) Note: 1. Meets EN 54-7: 2000 with Low, Medium and High sensitivites LPCB Ref. No. 199m/03 Bases: B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B501 Analogue sensor base B501DG Analogue sensor deep base B524IEFT Analogue sensor isolator base B524HTR Heater base B524RTE Latching relay base 322 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 199n to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products ED5351E ED4351E ED5351TE Class A1R conventional rate of rise heat detector (B401, B401DG, B401R and B401RSD bases) Class BS conventional heat detector (B401, B401DG, B401R, B401SD and B401RSD bases) Class A2S conventional fixed temperature heat detector (B401, B401R, B401RSD, B401SD and B401DG bases) LPCB Ref. No. 199n/07 199n/08 199n/14 Bases: B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B501 analogue sensor base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue sensor isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base Certificate No: 199p to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 010aq-(cl-2) to LPS 1274: 2005 EN 54-5: 2000 + A1: 2002 LPS 1265: 2004 Multi Criteria Detectors Certificated Products EDI-55 Analogue addressable CO/heat multisensor detector (EBI-10 base) Notes: 1. Approved with the following mode configurations:Mode 1 30 ppm with high thermal enhancement (most sensitive) Mode 2 33 ppm with CO only Mode 3 40 ppm with low thermal enhancement (nominal sensitivity) Mode 4 45 ppm with high thermal enhancement (least sensitive) Mode 5 heat onlyA1R 2. Mode 1 , 3, and 4 are approved to LPS1274:2005 and EN 54-5:2000 + A1: 2002 3. Mode 2 is approved to LPS 1265:2004 4. Mode 5 is approved to EN 54-5:2000 + A1:2002 LPCB Ref. No. 010aq/01 Conditions of approval include; ED2351TEM ESMI2251CTLE The EDI-55 should only be installed in accordance with the manufacturers recommendations. The EDI-55 should not be set only as a carbon monoxide fire detector where there is a specific risk of rapid burning/flaming fires. Refer to technical publication D01692 for limitations on the use of carbon monoxide fire detection. Conventional optical/thermal smoke & heat detector (B401, B401DG, B401R, B401SD and B401RSD bases) Note: 1. Meets the requirements of EN 54-5: 2000 at class A1R and EN 54-7: 2000 at High, Medium and Low. Analogue addressable multi-criteria fire detector and incorporating CO, photoelectric, thermal and IR sensors (B501, B501AP, B501DG and B524IEFT-1 bases) Note: Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria) EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R 199p/03 199t/01 Nuisance Environment Applications: 20 Oct 2014 323 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. Application 0, Application 1, Application 2, Application 3, Application 4, Application 5, Application 6, Alarm Level 4 Alarm Level 5 Alarm Level 4 or 5 Alarm Level 5 Alarm Level 5 Alarm Level 5 Alarm Level 5 EN54-7, LPS1279 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 Bases: B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B501 standard analogue detector base B501AP intelligent detector base B501DG Deep detector base B524IEFT Short circuit isolator base B524HTR Heater base B524RTE Latching relay base EBI-10 Standard Intelligent Mounting Base Philton Fire & Security Limited 61 Lower Road, Harrow, Middlesex HA2 0DE, United Kingdom Tel: +44(0) 20-8864-7534 • Fax: +44(0) 20 8864 8631 E-mail: [email protected] • Website: www.philton.com Certificate No: 404c to EN54-20:2006 Aspirating Smoke Detecors Certificated Products Guardian LaserSTAMP high sensitivity aspirating smoke detector Notes: 1. 2. 3. LPCB Ref. No. 404c/01 For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply complying with EN 54-4. The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.31%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. Pittway Tecnologica Srl. Via Caboto 19/3, 34147 Trieste, Italy Tel: +39 040 94 90111 • Fax: +39 040 38 2137 E-mail: [email protected] • Website: www.systemsensoreurope.com European Sales: System Sensor Europe, Life Safety Distribution AG, Wilstrasse 11 (Building U31), CH-8610 Uster, Switzerland Tel: +41 44 943 4424 • Fax: +41 44 943 4399 E-mail: [email protected] • Website: www.systemsensoreurope.com Certificate No: 199m to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005 324 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Point Smoke Detectors Certificated Products 22051EI ECO1003 2351E Vision 2020P 22051EISE 22051E Analogue addressable optical smoke sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity Conventional photoelectric smoke detector (ECO1000DB, ECO1000DBR and ECO1000DBRSD) Conventional photoelectric smoke detector (B401, B40DG, B401R, B401SD and B401RSD bases) Note: Meets the requirements of EN54-7:2000 at low, medium and high sensitivity settings Conventional photoelectric detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Intrinsically safe analogue addressable photoelectric smoke detector (B501, B501AP, B524HTR and B524RTE bases) Note: Meets EN54-7: 2000 at High, Normal & Low sensitivity settings Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity LPCB Ref. No. 199ab/01 199m/01 199m/03 199m/05 199m/07 199m/10 Bases: 2020B standard base 2020DB deep base 2020BSD standard base with schottky diode 2020DBSD deep base with schottky diode B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B501 standard analogue detector base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue sensor isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base ECO1000B standard base. ECO1000BSD standard base with schottky diode. ECO1000BR standard base, 470 ohm resistor. ECO1000BRSD standard base, 470 ohm resistor and schottky diode. ECO1000BR680 standard base, 680 ohm resistor. ECO1000BR680SD standard base, 680 ohm resistor and schottky diode. ECO1000BR1000 standard base, 1000 ohm resistor. ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode. ECO1000DB deep base ECO1000DBR deep base with 470 ohm resistor ECO1000DBRSD deep base with 470 ohm resistor and schottky diode ECO2000B mounting base. Certificate No: 199n to EN 54-5: 2000 + A1: 2002 Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005 Point Heat Detectors Certificated Products 52051EI 52051HTEI 52051REI ECO1005 ECO1005T 5351E 4351E 20 Oct 2014 Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Analogue addressable class BS fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Analogue addressable class A1R rate of rise heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Class A1R conventional thermal detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases) Class A2S conventional fixed temperature heat detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases) Class A1R conventional rate of rise heat detector (B401, B401DG, B401R, B401SD, & B401RSD bases) Class BS conventional heat detector (B401, B401 LPCB Ref. No. 199ac/01 199ac/02 199ac/03 199n/01 199n/06 199n/07 199n/08 325 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products ECO1004T Vision 2020F Vision 2020HF Vision 2020R 5451EIS 5351TE 52051RE 52051HTE 52051E LPCB Ref. No. DG, B401R, B401SD, & B401RSD bases) Class BS conventional high temperature heat detector (ECO1000DB, ECO1000DBR, ECO1000DBRSD, ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases) Class A2S conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Class BS conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Class A1R conventional rate of rise heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Intrinsically safe conventional A1R heat detector (B401 base) Conventional class A2S fixed temperature heat detector (B401, B401R, B401RSD, B401SD, B401DG bases) Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Analogue addressable class BS fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Analogue addressable class A1S fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) 199n/09 199n/10 199n/11 199n/12 199n/13 199n/14 199n/15 199n/16 199n/17 Bases: 2020B standard base 2020DB deep base 2020BSD standard base with schottky diode 2020DBSD deep base with schottky diode B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode B501 standard analogue detector base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue sensor isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base ECO1000B standard base. ECO1000BSD standard base with schottky diode. ECO1000BR standard base, 470 ohm resistor. ECO1000BRSD standard base, 470 ohm resistor and schottky diode. ECO1000BR680 standard base, 680 ohm resistor. ECO1000BR680SD standard base, 680 ohm resistor and schottky diode. ECO1000BR1000 standard base, 1000 ohm resistor. ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode. ECO2000B mounting base. ECO1000DB deep base. ECO1000DBR deep base with 470 ohm resistor ECO1000DBRSD deep base with 470 ohm resistor and schottky diode. Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A1: 2006 & CEA 4021: 2003 Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005 Multi-criteria Detectors Certificated Products 22051TLEI 22051TEI 326 Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: - LPCB Ref. No. 199aa/01 199aa/02 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products ECO1002 2351TEM Vision 2020PT 22051TLE 22051TE 2251CTLE-xx-yy LPCB Ref. No. Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Conventional photo-thermal detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases) Note :Meets the requirements of EN54:5-2000 at class A1R and EN54:7:2000 at pre-set sensitivity Conventional optical/thermal detector (B401, B401DG, B401R, B401SD, & B401RSD bases) Note: Meets the requirements of EN54-5:2000 at class A1R and EN54-7:2000 at 'High' 'Medium' and 'Low' sensitivity settings. Conventional photo thermal detector (2020B, 2020DB, 2020BSD and 2020DBSD bases) Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT1, B524HTR and B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal and IR sensors (B501, B501AP, B501DG, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1.) xx = (Range 0-99) ~ indicates the communication software protocol 2.) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3.) Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria) EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R Nuisance Environment Applications: Application 0, Alarm Level 4 Application 1, Alarm Level 5 Application 2, Alarm Level 4 or 5 Application 3, Alarm Level 5 Application 4, Alarm Level 5 Application 5, Alarm Level 5 Application 6, Alarm Level 5 Application 7, Alarm Level 5 199p/01 199p/03 199p/04 199p/06 199p/07 199t/01 EN54-7, LPS1279 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, LPS1279 and CEA 4021 Bases: 2020B standard base 2020DB deep base 2020BSD standard base with schottky diode 2020DBSD deep base with schottky diode B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode B501 standard analogue detector base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue sensor isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode 20 Oct 2014 327 PART 1: SECTION 4.1 COMMERCIAL DETECTORS ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode ECO1000DB deep base ECO1000DBR deep base with 470 ohm resistor ECO1000DBRSD deep base with 470 ohm resistor and schottky diode ECO2000B mounting base Certificate No: 199u to EN 54-12: 2002 Certificate No: 199w to EN 54-12: 2002 & EN 54-17: 2005 Beam Detectors Certificated Products 6500R 6500RS 6500-yy 6500S-yy LPCB Ref. No. 199u/01 Conventional optical beam detector Note: meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2 Conventional optical beam detector with self test facility Note: meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2 Analogue optical beam detector with short circuit isolator feature Note: 1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1,2,3,4 and Acclimate levels 1 & 2 2. yy = (Range 00-99) and indicates the software protocol Analogue optical beam detector with self test facility and short circuit isolator feature Note: 1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1,2,3,4 and Acclimate levels 1 & 2 2. yy = (Range 00-99) and indicates the software protocol Ancillaries: RTS151-KEY 6500 - LRK/BEAMLRK 6500 - MMK/BEAMMMK 6500 - SMK/BEAMSMK 199u/02 199w/01 199w/02 Remote test Station Long Range Kit Multi-Mounting Kit Surface Mounting Kit Certificate No: 199ad to EN54-20: 2006 Certificate No: 199ae to EN54-17: 2005 and EN54-20: 2006 Aspirating Smoke Detectors Certificated Products FL0111E FL0112E FL0122E 328 Analogue addressable stand alone single channel aspirating detector Notes: 1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by a power supply complying with EN54-4. 2. The approval of the detector is conditional upon the following requirements: System design, installation and commissioning shall be performed in accordance with the FAAST Advanced set-up and control guide (I56-3888-000). 3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeIQLT software (version 1.2.9). Analogue addressable stand alone single channel aspirating detector dual sensors Notes: 1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by a power supply complying with EN54-4. 2. The approval of the detector is conditional upon the following requirements: System design, installation and commissioning shall be performed in accordance with the FAAST Advanced set-up and control guide (I56-3888-000). 3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeIQLT software (version 1.2.9). Analogue addressable stand alone dual channel aspirating detector dual sensors Notes: 1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by a power supply complying with EN54-4. 2. The approval of the detector is conditional upon the following requirements: System design, installation and commissioning shall be performed in accordance with the FAAST Advanced set-up and control guide (I56-3888-000). LPCB Ref. No. 199ad/01 199ad/02 199ad/03 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products FL2011EI FL2012EI FL2022EI Base: B501AP LPCB Ref. No. 3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeIQLT software (version 1.2.9). Analogue addressable single channel loop-based aspirating detector (B501AP base) Notes: 1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by a power supply complying with EN54-4. 2. The approval of the detector is conditional upon the following requirements: System design, installation and commissioning shall be performed in accordance with the FAAST Advanced set-up and control guide (I56-3888-000). 3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeIQLT software (version 1.2.9). Analogue addressable single channel loop-based aspirating detector dual sensors (B501AP base) Notes: 1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by a power supply complying with EN54-4. 2. The approval of the detector is conditional upon the following requirements: System design, installation and commissioning shall be performed in accordance with the FAAST Advanced set-up and control guide (I56-3888-000). 3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeIQLT software (version 1.2.9). Analogue addressable dual channel loop-based aspirating detector dual sensors (B501AP base) Notes: 1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by a power supply complying with EN54-4. 2. The approval of the detector is conditional upon the following requirements: System design, installation and commissioning shall be performed in accordance with the FAAST Advanced set-up and control guide (I56-3888-000). 3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeIQLT software (version 1.2.9). 199ae/01 199ae/02 199ae/03 intelligent sensor base Plana Fabrega C/Caracas, 08030, Barcelona, Spain Tel: 0034 93 243 1111 • Fax: 0034 93 243 0350 E-mail: [email protected]; [email protected] Certificate No: 199m to EN 54-7: 2000 + A1: 2002 Smoke Detectors Certificated Products OPT1 Conventional photoelectric smoke detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR, ECO1000DBRSD bases) LPCB Ref. No. 199m/01 Bases: ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode ECO1000DB deep base ECO1000DBR deep base with 470 ohm resistor ECO1000DBRSD deep base with 470 ohm resistor and schottky diode 20 Oct 2014 329 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 199n to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products TEVOL Conventional photoelectric smoke detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR, ECO1000DBRSD bases) LPCB Ref. No. 199n/01 Bases: ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode ECO1000DB deep base ECO1000DBR deep base with 470 ohm resistor ECO1000DBRSD deep base with 470 ohm resistor and schottky diode Protec Fire Detection plc Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom Tel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273 E-mail: [email protected] • Website: www.protec.co.uk Certificate No: 201f to EN 54-7: 2000 Certificate No: 201p to EN 54-7: 2000 Certificate No: 201ab to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 201v to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products 6000PLUS/OP/S 6000PLUS/OP/SX 6000/OP 6000PLUS/OP 3000PLUS/OP Analogue addressable smoke detector with indoor sounder and short circuit isolator (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting 2) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms Analogue addressable smoke detector with indoor sounder and short circuit isolator (export) (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting 2) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Dutch Whoop, 500-1500Hz over 3s MK II Analogue addressable optical smoke detector (6000/BASE and 6000/DIB bases) Note: Meets requirements of EN 54-7: 2000 at the following mode settings: i. Normal sensitivity mode Analogue addressable smoke detector (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting Conventional Optical Scatter Smoke Detector (3000PLUS/BASE & 3000PLUS/FFBASE Bases) Note: 1. Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting LPCB Ref. No. 201ab/01 201ab/02 201p/01 201v/01 201v/02 Bases: 6000/BASE Standard low profile base 6000/DIB Isolator base 330 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS 3000/BASE Standard Base 6000PLUS/BASE, Standard mounting base 6000PLUS/FFBASE, Recessed mounting base N28-075-01, Plug and Play Fast Fix base N28-075-02, Plug and Play Surface base 3000PLUS/BASE Standard Mounting Base 3000PLUS/FFBASE Fast Fix Mounting Base Certificate No: 201g to EN 54-5: 2000 + A1: 2002 Certificate No: 201r to EN 54-5: 2000 Certificate No: 201w to EN 54-5: 2000 + A1: 2002 Certificate No: 201aa to EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Point Heat Detectors Certificated Products 6000PLUS/HT/S 6000PLUS/HT/SL 6000PLUS/HT/TSL 6000/TEMP 6000PLUS/HT 3000PLUS/TEMP56 3000PLUS/TEMP64 Analogue addressable heat detector with indoor sounder and short circuit isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2 2) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms Analogue addressable heat detector with indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2 2) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms 3) The beacon functionality is not included within the scope of this approval Analogue addressable heat detector with talking indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2 2) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Bell, 800Hz iv) Voice message, F_EVAC2: Female voice “evacuation message” V2, “Attention, attention. This is an emergency. Please leave the building by the nearest available exit”. 3) The beacon functionality is not included within the scope of this approval Analogue addressable heat detector (6000/BASE & 6000/DIB bases) Note: Meets requirements of EN 54-5: 2000 at Class A1 (High sensitivity) and A2 (Normal sensitivity). Analogue addressable heat detector (6000PLUS/BASE, 6000PLUS/FFBASE, N28-07501 and N28-075-02 bases) Note: Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2 Conventional Class A1 Heat Detector (3000PLUS/BASE, 3000PLUS/FFBASE) Notes: 1. Meets the requirements of EN 54-5: 2000 at Class A1 Conventional Class A2 Heat Detector (3000PLUS/BASE, 3000PLUS/FFBASE) Notes: 1. Meets the requirements of EN 54-5: 2000 at Class A2 LPCB Ref. No. 201aa/01 201aa/02 201aa/03 201r/01 201w/01 201w/02 201w/03 Bases: 3000/BASE standard base 6000/BASE standard low profile base 6000/DIB isolator base 6000PLUS/BASE, standard mounting base 6000PLUS/FFBASE, recessed mounting base N28-075-01, Plug and Play Fast Fix base N28-075-02, Plug and Play Surface base 20 Oct 2014 331 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 201j to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 Certificate No: 201q to EN 54-5: 2000, EN 54-7: 2000 and CEA 4021 Certificate No: 201s to EN 54-5: 2000, EN 54-7: 2000 and CEA 4021 Certificate No: 201u to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003 Certificate No: 201x to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 201y to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005, CEA4021: 2003 Certificate No: 201z to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 201ac to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005, CEA4021: 2003 Multi-criteria Detectors Certificated Products 6000PLUS/OPHT/I 6000/OPHT Mk II 6000/OPHTCO 6000PLUS/OPHT 6000PLUS/OPHT/S 6000PLUS/OPHT/SX 6000PLUS/OPHT/SL 6000PLUS/OPHT/TS 332 Analogue addressable multisensor detector with short circuit isolator (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings Analogue addressable optical smoke and Class A2 heat multisensor detector (6000/BASE & 6000/DIB bases). Note: 1) Meets requirements of EN 54-7: 2000 and CEA 4021 at the following mode settings only: i) Normal sensitivity mode ii) Low sensitivity mode Analogue addressable optical smoke, CO and Class A2 heat multisensor detector (6000/BASE & 6000/DIB bases) Notes: 1) Meets requirements of EN 54-7: 2000 and CEA 4021 at the following mode settings only: i) Normal sensitivity mode II) Low sensitivity mode 2) The CO element is not LPCB approved Analogue addressable multisensor detector (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings Analogue addressable multisensor detector with indoor sounder and short circuit isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms Analogue addressable multisensor detector with indoor sounder and short circuit isolator (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Dutch Whoop, 500-1500Hz over 3s Analogue addressable multisensor detector with indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms 4) The beacon functionality is not included within the scope of this approval Analogue addressable multisensor detector with talking indoor sounder and short circuit isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz LPCB Ref. No. 201ac/01 201q/01 201s/01 201u/01 201x/01 201x/02 201x/03 201x/04 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 6000PLUS/OPHT/TSX 6000PLUS/OPHT/TSL 6000PLUS/OPHTCO 6000PLUS/OPHTCO/S 6000PLUS/OPHTCO/SX 6000PLUS/OPHTCO/SL 6000PLUS/OPHTCO/TSL 20 Oct 2014 LPCB Ref. No. ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Bell, 800Hz iv) Voice Message, F_EVAC2: Female voice evacuation message V2, Attention, attention. This is an emergency. Please leave the building by the nearest available exit. Analogue addressable multisensor detector with talking indoor sounder and short circuit isolator (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Dutch Whoop, 500-1500Hz over 3s iv) Bell, 800Hz Analogue addressable multisensor detector with talking indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-07502 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Bell, 800Hz iv) Voice message, F_EVAC2: Female voice evacuation message V2, Attention, attention. This is an emergency. Please leave the building by the nearest available exit. 4) The beacon functionality is not included within the scope of this approval Analogue addressable multisensor and CO detector with short circuit isolator (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) The CO functionality is not included within the scope of this approval Analogue addressable multisensor and CO detector with indoor sounder and short circuit isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms 4) The CO functionality is not included within the scope of this approval Analogue addressable multisensor and CO detector with indoor sounder and short circuit isolator (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets rhe requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Dutch Whoop, 500-1500Hz over 3s 4) The CO functionality is not included within the scope of this approval Analogue addressable multisensor and CO detector with indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-07502 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms 4) The CO and beacon functionality are not included within the scope of this approval Analogue addressable multisensor and CO detector with talking indoor sounder short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 201x/05 201x/06 201y/01 201z/01 201z/02 201z/03 201z/04 333 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 6000PLUS/OPHTCO/TSLX LPCB Ref. No. 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Bell, 800Hz iv) Voice message, F_EVAC2: Female voice evacuation message V2, Attention, attention. This is an emergency. Please leave the building by the nearest available exit. 4) The CO and beacon functionality are not included within the scope of this approval Analogue addressable multisensor and CO detector with talking indoor sounder, short circuit isolator and beacon (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Dutch Whoop, 500-1500Hz over 3s iv) Bell, 800Hz 4) The CO and beacon functionality are not included within the scope of this approval 201z/05 Bases: 3000/BASE standard base 6000/BASE standard low profile base 6000/DIB isolator base 6000PLUS/BASE, standard mounting base 6000PLUS/FFBASE, recessed mounting base N28-075-01, Plug and Play Fast Fix base N28-075-02, Plug and Play Surface base Ravel Electronics Ltd Unit 11, Chancel Industrial Estate, Newhall Street, Willenhall WV13 1NX, United Kingdom Tel: 0845 835 8855 E-mail: [email protected] Certificate No: 512a-(cl-7) to EN54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products RE-336S LPCB Ref. No. 512a/02 Conventional 2 wire photoelectric smoke detector with remote LED output (RE-334B base) Base RE-334B 4-wire detector base Certificate No: 512b-(cl-4) to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA4021: 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products RE-336SH Conventional 2 wire photoelectric smoke and heat detector with remote LED output (RE334B base) LPCB Ref. No. 512b/02 Base RE-334B 4-wire detector base Certificate No: 512d-(cl-7) to EN54-5: 2000 + A1: 2002 334 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Heat Detectors Certificated Products RE-336H Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (RE-332B base) LPCB Ref. No. 512d/04 Base RE-332B 2-wire detector base Safety Hi-Tech Srl Via Cavour, 96 - 67051 Avezzano (AQ), Italy Tel: +39 0863 1940720 • Fax: +39 0863 1940724 E-mail: [email protected] • Website: www.safetyhitech.com Certificate No: 010p-(cl-3) to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products SHD90003 SHD90004 Venator-DE Heat Detectorand SHB90002 mounting base) Note: 1. Meets the requirements of EN54: Part 5 - Class A1R Venator-DE Heat Detectorand SHB90002 mounting base) Note: 1. Meets the requirements of EN54: Part 5 - Class CS LPCB Ref. No. 010p/05 010p/14 Base: SHB90001 Venator-DE standard mounting base SHB90002 Venator-DE standard relay mounting base Certificate No: 010q-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products SHD90001 SHD90002 Venator-DE Ionisation Smoke Detectorand SHB90002 mounting base) Venator -DE Optical Smoke Detectorand SHB90002 mounting base) LPCB Ref. No. 010q/05 010q/11 Base: SHB90001 Venator-DE standard mounting base SHB90002 Venator-DE standard relay mounting base Safex Fire Services Limited 202 Dhanraj Industrial Estate, Sun Mill Road, Lower Parel West, Mumbai-400 013, India Tel: +91-22-24938108 • Fax: +91-22-24950224 E-mail: [email protected] • Website: www.safexfire.com Certificate No: 506a-(cl-2) to EN 54-7 : 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products SF-871 Conventional photoelectric smoke detector (AHMB-L Base) LPCB Ref. No. 506a/01 Bases AHMB-L mounting base Certificate No: 506b-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 ,EN 54-5: 2000 + A1: 2002 , CEA 4021: 2003 20 Oct 2014 335 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Multi-Criteria Detectors Certificated Products SF-0315-2 SF-0315-3 SF-0315-4 (2 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) (3 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) (4 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) LPCB Ref. No. 506b/01 506b/02 506b/03 Bases AHMB-031 mounting base Sareme UAB Naugarduko str. 32/2, Vilnius LT2006, Lithuania Tel: +3705 2135047 • Fax: +3705 2333567 E-mail: [email protected] Certificate No: 512d to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products EA323-2 EA323-4 Conventional 2 wire 24 VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) LPCB Ref. No. 512d/01 512d/05 Bases: P/N854001 4-Wire detector base Certificate No: 512a to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products EA-318-2 EA-318-4-12 Conventional 2 wire photoelectric smoke detector (P/N852001 base) Conventional 4 wire photoelectric smoke detector (P/N854001 base) LPCB Ref. No. 512a/01 512a/03 Bases: P/N852001 2-wire detector base P/N854001 4-wire detector base Certificate No: 512b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 +A1: 2002 + A2: 2006 and CEA 4021: 2003 Multi-Criteria Detectors Certificated Products EA-318-2H EA-318-2H-LED Conventional 2 wire photoelectric smoke and heat detector (P/N852001 base) Conventional 2 wire photoelectric smoke and heat detector with remote LED output (P/N854001 base) LPCB Ref. No. 512b/01 512b/02 Bases: P/N854001 4-wire detector base P/N852001 2-wire detector base 336 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Schlumberger Oilfield UK PLC, Sensor Highway Limited (Schlumberger, Southampton) Unit 7, The Quadrangle, Abbey Park Industrial Estate, Romsey, Southampton, Hampshire SO51 9DL, United Kingdom Tel: +44 (0)1794 529600 • Fax: +44 (0)1794 514931 E-mail: [email protected] • Website: www.slb.com Certificate No: 648c to LPCB Test Schedule E120656/1.0 Linear Heat Detection System Certificated Products Sensa DTS240SC Distributed Temperature Sensor SC: Single Channel Notes: 1. Approval is conditional on the following: LPCB Ref. No. 648c/01 - The use of SensorLine II or SensorTube II optical fibres (Stainless Steel). - The optical fibre lengths should not exceed 4km. - The system should be installed and configured in accordance with the manufacturers instructions. - The zone/alarm configuration parameters should be set in accordance with the manufacturers instructions for an alarm response equivalent to Class A1R as specified in EN 54-5: 2000 + A1: 2002. Sensa DTS240TC 2. The product is known as the LTS240SC when supplied in a wall-mount or rack-mount housing. Distributed Temperature Sensor TC: Twin Channel 648c/01 Notes: 1. Approval is conditional on the following: - The use of SensorLine II or SensorTube II optical fibres (Stainless Steel). - The optical fibre lengths should not exceed 4km. - The system should be installed and configured in accordance with the manufacturers instructions. - The zone/alarm configuration parameters should be set in accordance with the manufacturers instructions for an alarm response equivalent to Class A1R as specified in EN 54-5: 2000 + A1: 2002. 2. The product is known as the LTS240TC when supplied in a wall-mount or rack-mount housing. Annex Sensor Highway Ltd. is part of Schlumberger Oilfield UK PLC and known as Schlumberger, Southampton Shenzhen Heiman Technology Co Ltd No 84 Fuqian Road, Yuexingwei Community, Guanlan, Longhua New District, Shenzhen 518110, China Tel: +86 75584193930 x8018 E-mail: [email protected] Certificate No: 1138a to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products HM-612PC-4 HM-612PC-2 HM-613PC-4 HM-613PC-2 20 Oct 2014 Conventional 4-WIRE photoelectric smoke detector with relay output (B-01 base) Conventional 2-WIRE photoelectric smoke detector with remote LED (B-01 base) Conventional 4-WIRE photoelectric smoke detector with relay output (B-01 base) Conventional 2-WIRE photoelectric smoke detector with remote LED (B-01 base) LPCB Ref. No. 1138a/01 1138a/02 1138a/03 1138a/04 337 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Base B-01 Standard base SHIELD FIRE, SAFETY AND SECURITY LTD Redburn House, 2a Tonbridge Road, Romford, Essex RM3 8QE, United Kingdom Tel: +44 207 712 1610 • Fax: +44 207 712 1578 E-mail: [email protected] • Website: www.shieldglobal.com Certificate No: 548k-(cl-4) to EN 54-12: 2002 Beam Detectors Certificated Products D-A430/R Intelligent optical beam detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31dB LPCB Ref. No. 548k/01 Certificate No: 548d-(cl-4) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products D-C401 D-A411 Conventional photoelectric smoke detector (DZ-03 base) Intelligent photoelectric smoke detector (DZ-03 base) LPCB Ref. No. 548d/01 548d/02 Bases: DZ-03 Standard detector base Certificate No: 548c-(cl-4) to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products D-C402 D-A412 Conventional Class A1R heat detector (DZ-03 base) Intelligent Class A1R heat detector (DZ-03 base) LPCB Ref. No. 548c/01 548c/02 Bases: DZ-03 Standard detector base Certificate No: 548q-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA 4021: 2003 Certificated Products D-C400 D-A410 Conventional Optical Smoke and Heat Multisensor Detector (DB-CA Base, DZ-03D Base & DZ-03 Base) Notes: 1. Meets the requirements of EN 54-7: 2000 at sensitivity setting Mode 1 2. Meets the requirements of EN 54-5: 2000 at Class A2R Intelligent Optical Smoke and Heat Multisensor Detector (DZ-03 Base) Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity setting Mode 1 2. Meets the requirements of EN 54-5: 2000 at Class A2R LPCB Ref. No. 548q/01 548q/02 Bases DB-CA Active EOL Unit DZ-03D Diode Base DZ-03 Standard Base 338 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Siemens Switzerland Limited, Building Technologies Division International Headquarters, Gubelstrasse 22, CH-6301 Zug, Switzerland Tel: +41 (0) 41 724 24 24 • Fax: +41 (0) 41 724 35 22 Manufacturing at: Volketswil Factory, Industriestrasse 22, CH-8604 Volketswil, Switzerland Tel: +41 1 922 6111 • Fax: +41 1 922 6450 UK Sales: Siemens Building Technologies Limited, FSP Division Tel: +44 (0)1784 461616 • Fax: +44 (0)1784 464646 Certificate No: 126x-(cl-1) to EN 54:7: 2000 + A1:2002 + A2:2006 Certificate No: 126ab-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 126am-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005 Certificate No: 531c-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 531d-(cl-1) to EN 54-7:2000 + A1:2002 + A2: 2006, EN 54-17: 2005 and CEA4021: 2003-07 Certificate No: 531e-(cl-1) to EN 54-7: 2000 + A1: 2002 + A1: 2006 and EN 54-17: 2005 Certificate No: 1161a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 1161b-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005 Point Smoke Detectors Certificated Products DO1101A DO1101A-Ex DO1151A DOT1151A DOT1151A-Ex DO1131A DO1152A DOT1131A DOT1152A FDO241 FDO221 DO1131A DO1152A DOT1131A DOT1152A 20 Oct 2014 Conventional photoelectric smoke detector (DB1101A base) Intrinsically safe conventional photoelectric smoke detector (DB1101A base) Addressable photoelectric smoke detector (DB1151A base) Note: Meets EN54-7 at Personen/life sensitivity settings Addressable photoelectric smoke detector with thermal enhancement (DB1151A base) Note: Meets EN54-7 at Personen/life sensitivity and Immobilien/property sensitivity settings Intrinsically safe conventional photoelectric smoke detector with thermal enhancement (DB1151A base) Note: Meets EN54-7 at Personen/life sensitivity and Immobilien/property sensitivity settings Addressable photoelectric smoke detector with short circuit isolator (DB1131A base) Note: Meets EN54-7:2000 at standard and high sensitivity Settings Addressable photoelectric smoke detector with short circuit isolator (DB1151A base) Note: Meets EN54-7:2000 at Personen/life sensitivity and Immobilien/property sensitivity settings Addressable photoelectric smoke detector with thermal enhancement and short circuit isolator (DB1131A base) Note: Meets EN54-7:2000 at standard and high sensitivity Settings Addressable photoelectric smoke detector with thermal enhancement and short circuit isolator (DB1151A base) Note: Meets EN54-7:2000 at Personen/life sensitivity and Immobilien/property sensitivity settings Analogue addressable photoelectric smoke detector with short circuit isolator (FDB221, FDB201, FDB291 and FDB292 bases) Analogue addressable photoelectric smoke detector with short circuit isolator (FDB221, FDB201, FDB291 and FDB292 bases) Addressable photoelectric smoke detector with short circuit isolator (DB1131A base) Note: 1. Meets EN54-7: 2000 at Standard and High sensitivity settings Addressable photoelectric smoke detector with short circuit isolator (DB1151A base) Note: 1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings Addressable photoelectric smoke detector with thermal enhancement and short circuit isolator (DB1131A base) Note: 1. Meets EN54-7: 2000 at Standard and High sensitivity settings Addressable photoelectric smoke detector with thermal enhancement and short circuit isolator (DB1151A base) LPCB Ref. No. 1161a/01 1161a/02 1161a/03 1161a/04 1161a/05 1161b/01 1161b/02 1161b/03 1161b/04 126ab/01 126ab/02 126am/03 126am/05 126am/06 126am/09 339 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products R970 DO1101A DO1101A-Ex DO1151A DOT1151A DOT1151A-Ex OH320C OP320C OH620 OP620 OP820 OH720 OP720 OH320A OP320A LPCB Ref. No. Note: 1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings Scattered light smoke detector (Z94 base) Note: 1. Meets requirements of EN54-7 at standard (2.5%/m) and increased (1.7%/m) sensitivity setting Conventional photoelectric smoke detector (DB1101A base) Intrinsically safe conventional photoelectric smoke detector (DB1101A base) Addressable photoelectric smoke detector (DB1151A base) Note: 1. Meets EN54-7 at Personen/life sensitivity settings Addressable photoelectric smoke detector with thermal enhancement (DB1151A base) Note: 1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings Intrinsically safe addressable photoelectric smoke detector with thermal enhancement (DB1151A base) Note: 1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings Conventional photoelectric smoke detector with thermal enhancement (SO320 base) Conventional photoelectric smoke detector (SO320 base) Analogue addressable photoelectric smoke detector with thermal enhancement (SO620 base) Note: Meets the requirements of EN54-7: 2000 at Standard and High sensitivity settings Analogue addressable photoelectric smoke detector (SO620 base) Note: Meets the requirements of EN54-7: 2000 at Standard and High sensitivity settings Analogue addressable photoelectric smoke detector (SO820 base) Note: Meets the requirements of EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings Analogue addressable multi sensor smoke detector (DB720, DB721 bases) Note: 1. Meets the requirements of EN 54-7 in the following sensitivities: 1 - Robust 3.5%/m 2 - Sensitive 2.5%/m Analogue addressable smoke detector with short circuit isolator (DB720, DB721 bases) Note: 1. Meets the requirements of EN 54-7 in the following sensitivities: 1 - Standard 2.5%/m 2 - Sensitive 1.8%/m Analogue addressable photoelectric smoke detector with thermal enhancement and short circuit isolator (SO320 base) Note: 1. Meets EN54-7: 2000 at Standard and High sensitivity settings Analogue addressable photoelectric smoke detector with short circuit isolator (SO320 base) Note: 1. Meets EN54-7: 2000 at Standard and High sensitivity settings 126x/01 126x/02 126x/03 126x/04 126x/05 126x/06 531c/02 531c/04 531c/05 531c/06 531c/07 531d/01 531e/01 531e/02 531e/03 Bases: Z94 base FDB221 base FDB201 base "Collective" FDB291 base attachment surface FDB292 base attachment surface wet DB720 Detector base DB721 Detector base with loop contact DB1101A base DB1131A base DB1151A base DBZ1191 base attachment SO620 Analogue addressable (AnalogPLUS) detector base SO820 Analogue addressable (Interactive) detector base SO320 base for SynovaTM 300 series detectors DB1101A base Base for collective fire detectors DB1151A base Base for interactive fire detectors DB1131A base Base for analogPLUS fire detectors 340 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 126aa-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 126an-(cl-1) to EN 54-5: 2000 + A1: 2002 Certificate No: 531b-(cl-1) to EN 54-5: 2000 + A1: 2002 Certificate No: 531f-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 126av-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 1161c-(cl-1) to EN 54-5: 2000 + A1: 2002 Certificate No: 1161d-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005 Point Heat Detectors Certificated Products DT1101A DT1101A-Ex DT1102A DT1102A-Ex DT1151A-Ex DT1131A DT1152A FDT241 FDT221 DT1101A DT1101A-Ex DT1102A DT1102A-Ex DT1151A-Ex DT1131A DT1152A HI320C HI322C HI620 HI820 HI720 HI722 HI320A HI322A Conventional class A1R heat detector (DB1101A base) Conventional intrinsically safe class A1R heat detector (DB1101A base) Conventional class B heat detector (DB1101A base) Conventional intrinsically safe class B heat detector (DB1101A base) Analogue addressable intrinsically safe heat detector (DB1151A base) Note: Meets EN54-5: 2000 at class A1R and class B Analogue addressable class A1R heat detector with short circuit isolator (DB1131A base) Analogue addressable heat detector with short circuit isolator (DB1151A base) Note: Meets EN54-5: 2000 at class A1R and class BS Analogue addressable rate of rise heat detector with short circuit isolator. (FDB221, FDB201, FDB291 and FDB292 bases) Note: Meets EN 54-5: 2000 at Class A1R, A1S, BR and BS. Analogue addressable rate of rise heat detector with short circuit isolator (FDB221, FDB201, FDB291 and FDB292 bases) Note: Meets EN 54-5: 2000 at Class A1R and BR Conventional class A1R heat detector (DB1101A base) Conventional intrinsically safe class A1R heat detector (DB1101A base) Conventional class B heat detector (DB1101A base) Conventional intrinsically safe class B heat detector (DB1101A base) Analogue addressable intrinsically safe heat detector (DB1151A base) Note: Meets EN54-5: 2000 at class A1R and class B Analogue addressable class A1R heat detector with short circuit isolator (DB1131A base) Analogue addressable heat detector with short circuit isolator (DB1151A base) Note: 1. Meets EN 54-5:2000 at class A1R and class BS Conventional class A1R heat detector (SO320 base) Conventional class A2 heat detector (SO320 base) Analogue addressable (AnalogPLUS) Class A1R heat detector (SO620 base) Analogue addressable (Interactive) heat detector (SO820 base) Note: Meets the requirements of EN54-5: 2000 at class A1R and class BR Analogue addressable class A2S and A2R heat detector with short circuit isolator (DB720, DB721 bases) Notes: 1. Meets the requirements of EN 54-5 at classes A2S and A2R Analogue addressable class A2S heat detector with short circuit isolator (DB720, DB721 bases) Notes: 1. Meets the requirements of EN 54-5 at class A2S Analogue addressable class A1R heat detector with short circuit isolator (SO320 base) Analogue addressable class A2 heat detector with short circuit isolator (SO320 base) LPCB Ref. No. 1161c/01 1161c/02 1161c/03 1161c/04 1161c/05 1161d/01 1161d/02 126aa/01 126aa/02 126an/01 126an/02 126an/03 126an/04 126an/06 126av/01 126av/02 531b/03 531b/04 531b/05 531b/06 531f/01 531f/02 531f/03 531f/04 Bases: Z94 base DFB1190 base FDB221 base FDB201 base “Collective” FDB291 base attachment surface FDB292 base attachment surface wet DB720 Detector base DB721 Detector base with loop contact DB1101A base for conventional addressing DB1131A base for analogue addressing DB1151A base for interactive fire detectors SO320 base for SynovaTM 300 series detectors SO620 Analogue addressable (AnalogPLUS) detector base SO820 Analogue addressable (Interactive) detector base DB1101A Base for collective fire detectors DB1151A Base for interactive fire detectors 20 Oct 2014 341 PART 1: SECTION 4.1 COMMERCIAL DETECTORS DB1131A Base for analogPLUS fire detectors Certificate No: 126ag-(cl-1) to EN 54-12: 2002 and EN 54-17: 2005 Certificate No: 126ak-(cl-1) to EN 54-12: 2002 and EN 54-17: 2005 Beam Detectors Certificated Products FDL241-9 DLO1191 LPCB Ref. No. 126ag/01 Analogue addressable beam detector with short circuit isolator (FDLB291 base) Note: Certified at sensitivity settings 30%, 50% and 65% Optical beam smoke detector with short circuit isolator (DLB1191A base) Note: 1. Certified at sensitivity setting 30%, 50% and 65% 126ak/01 Bases: FDLB291 base DLB1191A base Certificate No: 126bb to EN 54-10: 2002 + A1: 2005 Certificate No: 126af-(cl-1) to EN 54-10: 2001 + A1: 2005 and EN 54-17: 2005 Certificate No: 126bc to EN 54-10: 2002 + A1: 2005 and EN 54-17: 2005 Flame Detectors Certificated Products DF1192 DF1151-Ex DF1191 DF1192 FDF221-9 FDF241-9 DF1101-Ex LPCB Ref. No. 126bb/01 Analogue Addressable Infra Red Flame Detector (DFB 1190 base) Note: Certified to EN 54-10:2002 + A1: 2005 at Class 1 and 2 Analogue Addressable IS Infra Red Flame Detector with Short Circuit Isolator (DFB1190 Base) Note: 1. Certified to EN 54-10: 2002 + A1: 2005 at Class 1 and 2 Analogue Addressable Infra Red Flame Detector with Short Circuit Isolator (DFB1190 Base) Note: 1. Certified to EN 54-10: 2002 + A1: 2005 at Class 1 and 2 Analogue Addressable Infra Red Flame Detector with Short Circuit Isolator (DFB1190 Base) Note: 1. Certified to EN 54-10: 2002 + A1: 2005 at Class 1 and 2 Analogue Addressable Infra Red Flame Detector with Short Circuit Isolator (FDFB291 base) Note: 1. Certified to EN 54-10: 2002 + A1: 2005 at Class 1 and 2 Analogue Addressable Infra Red Flame Detector with Short Circuit Isolator (FDFB291 base) Note: 1. Certified to EN 54-10: 2002 + A1: 2005 at Class 1 and 2 Conventional I.S. infra red flame detector (DFB 1190 base) Note: 1. Certificated in "increased" & "standard" sensitivity settings - Class 1 and 2 respectively. 126bc/01 126bc/02 126bc/03 126bc/04 126bc/05 126s/03 Bases: Z94 base DFB 1190 base FDFB291 base Certificate No: 126ah-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003 and EN 54-17: 2005 Certificate No: 126ba-(cl-1) to EN 54-5: 2001 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003 Multi-criteria Detectors Certificated Products FDOOT241-9 342 Analogue addressable multisensor detector with short circuit isolator (FDB201, FDB202, FDB221, FDB222, FDB291 and FDB293 bases) Note: Meets the requirements of EN 54-5: 2000 at LPCB Ref. No. 126ah/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products FDOOTC241 LPCB Ref. No. Class A2R & A2S and EN 54-7: 2000 at sensitivity settings: Parameter No. 1 Universal Parameter No. 2 Robust with thermal enhancement Parameter No. 3 Sensitive Parameter No. 4 Balanced with thermal enhancement Parameter No. 5 Suppression with thermal enhancement Parameter No. 6 Response with thermal enhancement Parameter No. 7 Robust / BGD with thermal enhancement Analogue addressable multisensor detector with short circuit isolator (FDB221, FDB222, FDSB291 & FDSB293 bases) Note - the following modes are approved Mode 0 - Neural Fire Detector: 0.0) High Compensation 0.2) Robust 0.4) Balanced 0.5) Suppression 0.6) Fast Response 0.7) High Compensation 0.9) High Sensitive Fast 0.10) Balanced CO 0.12) Suppression CO 126ah/03 Mode 1 - Heat Detector 1.1) A1R 1.2) BR 1.3) A1S 1.4) BS FDOOT241-A3 Mode 2 - Smoke Detector 2.0) Universal 2.1) Universal 2.2) Robust 2.3) Sensitive Multisensor detector with short circuit isolator (FDB221, FDB222, DB1131A, FDB291, FDB293 and FDB241 bases) Notes: - the following modes are approved 126ah/04 1 - Parameter sets for detection when connected to FDnet communication protocol Mode 0 - Neural Fire Detector-Multisensor Detector: No Parameter Robust 2 Balanced 4 Suppression 5 Fast Response 6 High Compensation 7 High Sensitive Fast 9 Mode 1 - Heat Detector: Parameter A1R BR A1S BS No 1 2 3 4 Mode 2 - Smoke Detector: Parameter Universal Robust Sensitive No 1 2 3 2 - Parameter sets for detection when connected to AnalogPLUS communication protocol Smoke only as DO1131A Parameter Sensitive Universal Fast No 3 4 Smoke with heat enhancement as DOT1131A Parameter No Fast Response 6 Universal Fast 12 20 Oct 2014 343 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. Rate of Rise heat detection as DT1131A No Parameter A1R 1 FDOOT241-A9 Fixed temperature heat detection as DT1132A Parameter No BS 4 Multisensor detector with short circuit isolator (FDB221, FDB222, FDB201, FDB202, FDB299, FDB291, FDB293, DB1101A and SPF600 bases) Notes - the following modes are approved 126ah/05 1 - Parameter sets for detection when connected to FDnet communication protocol and collective detector line Mode 0 - Neural Fire Detector-Mutisensor Detector: Parameter No Robust 2 Balanced 4 Suppression 5 Fast Response 6 High Compensation 7 High Sensitive Fast 9 Mode 1 - Heat Detector: Parameter A1R BR A1S BS OOH740 No 1 2 3 4 Mode 2 - Smoke Detector: No Parameter Universal 1 Robust 2 Sensitive 3 Analogue addressable multisensor detector with short circuit isolator (DB720, DB721, DB722, BA720 & DB721D bases) 126ba/01 Notes - the following modes are approved 1 - Parameter sets for detection when connected to C-Net detector line Mode 0 - Neural Fire Detector: Parameter Nr Robust 2 Balanced 4 Suppression 5 Fast Response 6 High Compensation 7 High Sensitive Fast 9 Mode 1 - Heat Detector: Parameter Nr A1R 1 BR 2 A1S 3 BS 4 Mode 2 - Smoke Detector: Parameter Nr Universal 1 Robust 2 Sensitive 3 2 - Parameter sets for detection when connected to collective detector line Parameter Standard Plus Suppression High Sensitive Fast 344 Resistor value in detector base 33 Kilo Ohms 68 Kilo Ohms 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products OOHC740 LPCB Ref. No. Analogue addressable multisensor detector with short circuit isolator (DB720, DB721, DB722 & BA720 bases) 126ba/02 Note - the following modes are approved Parameter sets for detection when connected to C-Net detector line Mode 0 - Neural Fire Detector: Nr Parameter Robust 2 Balanced 4 Suppression 5 Fast Response 6 High Compensation 7 High Sensitive Fast 9 Bases: FDB221 FDB201 FDB202 FDB222 FDB291 FDB292 FDB293 DB720 DB721 DB722 DB721D BA720 DB1131A FDB241 FDB299 DB1101A SPF600 Mode 1 - Heat Detector: Parameter A1R BR A1S BS Nr 1 2 3 4 Mode 2 - Smoke Detector: Parameter Universal Robust Sensitive Nr 1 2 3 base with stand offs base “Collective” with stand offs base “Collective” without stand offs base without stand offs base attachment surface base attachment surface wet base attachment surface wet Detector base Detector base with loop contract Detector Base with loop contract Detector Base with snap lock Base with surface mounted line Standard base Standard base for special location Base Base Base Certificate No: 126az-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005 and CEA 4021: 2003 Multi-Sensor Detectors Certificated Products FDOOT221 Analogue addressable multisensor detector with short circuit isolator (FDB221, FDB222, FDB291 and FDB293 bases) Note: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings: Parameter No. 2 Parameter No. 4 LPCB Ref. No. 126az/01 Robust with thermal enhancement balanced with thermal enhancement Bases FDB221 base with stand offs FDB222 base without stand offs FDB291 base attachment surface FDB293 base attachment surface wet 20 Oct 2014 345 PART 1: SECTION 4.1 COMMERCIAL DETECTORS SMS (Novar Systems Ltd) Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2100 • Fax: +44 (0)116 246 2016 Website: www.smsfire.co.uk Certificate No: 042ak to EN 54-5: 2000 + A1: 20002, EN 54-3: 2001 + A1: 2002, CEA GEI 1-084: Draft 08.08.00, CEA GEI 1-052: 11.06.97 Draft 2.0, Point Heat Detectors Certificated Products SEN-780 SEN-780-ST S-Quad analogue addressable Class P heat detector with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1. Meets the requirement of EN 54: Part 5 at the following settings: State 0 - Class A1 State 5 - Class B 2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Contiuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs S-Quad analogue addressable Class P heat detector with sounder and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1. Meets the requirement of EN 54: Part 5 at the following settings: State 0 - Class A1 State 5 - Class B 2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Contiuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3. Strobe note included in scope of approval LPCB Ref. No. 042ak/01 042ak/03 Bases: S4-700 standard base S4-FLUSH semi-flush fixing kit Certificate No: 042an to EN 54-7: 2000 + A1: 2002, EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002, EN 54-17: 2005, EN 54-18: 2005 and CEA 4021: 2003, Certificate No: 042bf to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005 Certificate No: 567ac-(cl-1) to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN54-17: 2005, EN54-18: 2005, EN54-23: 2010 Certificate No: 567j-(cl-1) to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1 :2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005, Certificate No: 567ab-(cl-1) to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005, EN 54-23: 2010, Certificate No: 567aa-(cl-1) to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005, Multi Criteria Detectors Certificated Products SEN-770 SEN-770-ST 346 S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1. Meets the requirement of EN 54-5 and EN 54-7 at the following settings: State 0 - Medium optical / Class A1 heat 2. Meets the requirements of EN 54-3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector with sounder and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1. Meets the requirement of EN 54- 5 and EN 54-7 at the following settings: State 0 - Medium optical / Class A1 heat 2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3. Strobe not included in scope of approval. LPCB Ref. No. 042an/04 042an/06 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products SEN-710 SEN-780-S SEN-770-VAD-HPR SEN-770-VAD-HPW SEN-770-VAD-LPW SEN-780-VAD-HPR 20 Oct 2014 LPCB Ref. No. S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector (S4-700 base with or without S4-FLUSH mounting kit) Note: 1. Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat Analogue Addressable Class P Heat Sensor with Sounder (S4-701 base) Notes:1. Meets the requirements of EN 54-3:2001 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5:2000 at the following settings: State 0 - Class A1 heat State 5 - Class B heat 3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder and Red Visual Alarm (S4-701 Base) Notes: 1. Meets the requirements of EN 54-3 at the following sounder tone settings High- Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 - Medium Optical / Class A1 Heat State 5 - Medium Optical / Class B Heat State 8 - Delayed Medium Optical / Class A1 Heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 5423 for the following - Category (light pattern details @ High power setting - (Category C: C-3-14 and Category O: O-4.5-14) @ Medium power setting - (Category C: C-3-13 and Category O: O-4-13) @ Low power setting - (Category C: C-3-10 and Category O: None) - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder and White Visual Alarm (S4-701 Base) Notes: 1. Meets the requirements of EN 54-3 at the following sounder tone settings: High- Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 - Medium Optical / Class A1 Heat State 5 - Medium Optical / Class B Heat State 8 - Delayed Medium Optical / Class A1 Heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following: - Category (light pattern details) @ High power setting - (Category C: C-6-16 and Category O: None) @ Medium power setting - (Category C: C-3-14 and Category O: O-5-14) @ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8 - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder and White Visual Alarm (S4-701 Base) Notes: 1. Meets the requirements of EN 54-3 at the following sounder tone settings: High- Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 - Medium Optical / Class A1 Heat State 5 - Medium Optical / Class B Heat State 8 - Delayed Medium Optical / Class A1 Heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 5423 for the following: - Category (light pattern details) @ Low power setting - (Category C: C-3-10 and Category O: None) - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C Analogue Addressable Class P Heat Sensor with Red Visual Alarm and Sounder (S4-701 042bf/01 567aa/01 567ab/01 567ab/02 567ab/03 567ac/03 347 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. Base) Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 at the following settings: State 0 - Class A1 heat State 5 - Class B heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following: - Category (light pattern details) @ High power setting - (Category C: C-3-14 and Category O: O-4.5-14) @ Medium power setting - (Category C: C-3-13 and Category O: O-4-13) @ Low power setting - (Category C: C-3-10 and Category O: None) - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C SEN-780-VAD-LPW Analogue Addressable Class P Heat Sensor with White Visual Alarm and Sounder (S4701 Base) Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 at the following settings: State 0 - Class A1 heat State 5 - Class B heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23 for the following: - Category (light pattern details) @ Low power setting - (Category C: C-3-10 and Category O: None) - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C 567ac/04 SEN-780-VAD-HPW Analogue Addressable Class P Heat Sensor with White Visual Alarm and Sounder (S4701 Base) Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 at the following settings: State 0 - Class A1 heat State 5 - Class B heat 3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 5423: - Category (light pattern details) @ High power setting - (Category C: C-6-16 and Category O: None) @ Medium power setting - (Category C: C-3-14 and Category O: O-5-14) @ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8 - Synchronization - Flash rate 2 seconds (0.5Hz) 4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C 567ac/05 SEN-770-S Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with Sounder (S4-701 base) Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings: State 0 -Medium optical / Class A1 heat 3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C 567j/08 Bases: S4-700 standard base S4-701 S4 Quad Plate and Base S4-FLUSH Semi-flush fixing kit Certificate No: 042be to EN54-5: 2000 + A1: 2002, EN54-17: 2005, EN54-18: 2005 Certificate No: 042bd to EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005 348 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Point Smoke Detectors Certificated Products SEN-715 S-Quad analogue addressable optical smoke detector (S4-700 base with or without S4-FLUSH mounting kit) Note: 1. Meets the requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical SEN-720 S-Quad analogue addressable Class P heat detector (S4-700 base with or without S4-FLUSH mounting kit) Note: 1. Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Class A1 heat LPCB Ref. No. 042bd/01 042be/01 Bases: S4-700 standard base S4-FLUSH semi-flush fixing kit Sterling Safety Systems Unit B12a, Holly Farm Business Park, Honiley, Warwickshire CV8 1NP, United Kingdom Tel: +44(0)1926485282 • Fax: +44(0)1926485090 E-mail: [email protected] • Website: www.sterlingsafety.co.uk Certificate No: 928a to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 928d to EN 54-5: 2000 + A1: 2002 Certificate No: 928j-(cl-6) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008 Point Heat Detectors Certificated Products HFI-TA-01 HFI-TAE-01 HFW-TA-01 Bases HFI-UB-01 HFI-DUB-01 HFI-DMB-01 HFI-DDB-01 HFI-UBS-01 HFI-DUBS-01 HFI-DMBS-01 HFI-DDBS-01 WAB100 Analogue addressable Class P heat detector with short circuit isolator (HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable Class P heat detector lite (HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B Wireless heat detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1R 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928a/01 928d/01 928j/01 Universal adaptor base Deep adaptor base Vega adaptor base Vega deep adaptor base Universal adaptor base with shorting clip Deep adaptor base with shorting clip Vega adaptor base with shorting clip Vega deep adaptor base with shorting clip Wireless Adaptor Base Certificate No: 928b to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 928e to EN 54-7: 2000 + A1: 2002 + A2: 2006 20 Oct 2014 349 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Point Smoke Detectors Certificated Products HFI-PA-01 Analogue addressable photoelectric smoke detector with short circuit isolator (HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable photoelectric smoke detector lite (HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low HFI-PAE-01 Bases HFI-UB-01 HFI-DUB-01 HFI-DMB-01 HFI-DDB-01 HFI-UBS-01 HFI-DUBS-01 HFI-DMBS-01 HFI-DDBS-01 LPCB Ref. No. 928b/01 928e/01 Universal adaptor base Deep adaptor base Vega adaptor base Vega deep adaptor base Universal adaptor base with shorting clip Deep adaptor base with shorting clip Vega adaptor base with shorting clip Vega deep adaptor base with shorting clip Certificate No: 928c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003 Certificate No: 928f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003 Multi-Sensor Detectors Certificated Products HFI-MA-01 HFI-MAE-01 350 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable Class P heat and photoelectric smoke multi-sensor detector lite HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFI-DMBS-01 and HFI-DDBS-01 bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke LPCB Ref. No. 928c/01 928f/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Bases HFI-UB-01 HFI-DUB-01 HFI-DMB-01 HFI-DDB-01 HFI-UBS-01 HFI-DUBS-01 HFI-DMBS-01 HFI-DDBS-01 Universal adaptor base Deep adaptor base Vega adaptor base Vega deep adaptor base Universal adaptor base with shorting clip Deep adaptor base with shorting clip Vega adaptor base with shorting clip Vega deep adaptor base with shorting clip Certificate No: 928k-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008 Smoke Detectors Certificated Products HFW-PA-01 Bases: WAB100 Wireless optical smoke detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-7 in the normal sensitivity setting 2. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928k/01 Wireless Adaptor Base Certificate No: 928m-(cl-6) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003 Multi-Criteria Detectors Certificated Products HFW-MA-01 Bases: WAB100 20 Oct 2014 Wireless multi-criteria detector (WAB100 base) Notes: 1. Meets the requirements of EN 54-5 for Class A1 2. Meets the requirements of EN 54-7 in the normal sensitivity setting 3. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery LPCB Ref. No. 928m/01 Wireless Adaptor Base 351 PART 1: SECTION 4.1 COMMERCIAL DETECTORS System Sensor 3825 Ohio Avenue, Saint Charles, Illinois 60174, USA Tel: +1 630 377 6580 • Fax: +1 630 377 7245 Website: www.systemsensor.com European Sales Enquiries: System Sensor Europe Tel: +44 (0)1403 891920 • Fax: +44 (0)1403 891921 Certificate No: 118h to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products 7251 Analogue addressable photoelectric laser smoke detector (B501, B501AP, B501DG, B524IEFT, B524IEFT-1 bases) Note: meets requirements of EN 54: Part 7 at sensitivities 7 to 9 inclusive LPCB Ref. No. 118h/01 Bases: B501 analogue sensor base B501AP intelligent detector base B501DG deep base B524IEFT short circuit isolator base B524IEFT-1 short circuit isolator base System Sensor Europe KAC House, Thornhill Road, North Moons Moat, Redditch, Worcestershire B98 9ND, United Kingdom Tel: +44 (0)1527 406700 • Fax: +44 (0)1527 406699 Website: www.systemsensoreurope.com Certificate No: 118h to EN54-7: 2000 Certificated Products LZR-1M Analogue addressable photoelectric laser smoke detector (B501, B501DG, B524IEFT, B524IEFT-1 bases) Note: meets requirements of EN 54: 7 at sensitivities 7 to 9 inclusive LPCB Ref. No. 118h/01 Bases B501DG deep base B524IEFT short circuit isolator base B524IEFT-1 short circuit isolator base System Sensor, Honeywell International (I) PVT. Limited Sector 36, Pace City - II, Gurgaon - 122 004, Haryana, India Tel: +91 124 4752700 • Fax: +91 124 4752750 E-mail: [email protected] Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 550d to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Smoke Detectors Certificated Products 2351E 352 Conventional photoelectric smoke detector LPCB Ref. No. 550a/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products EC01003 FL/1003 2251EM 22051E-xx-yy 2FA51 22051EI-xx-yy LPCB Ref. No. (B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases) Note: Meets the requirements of EN54-7:2000 at low, medium & high sensitivity settings. Conventional photoelectric smoke detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases) Conventional photoelectric smoke detector (FL/1000B base) Analogue addressable optical smoke detector (B501, B501DG and B5241EFT-1 bases) Notes : Meets EN 54-7 with low, medium and high sensitivity settings Analogue addressable optical smoke detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3) meets the requirements of EN 54-7: 2000 at high and low sensitivity Conventional photoelectric smoke detector (BFA1 base) Analogue addressable optical smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3) Meets the requirements of EN 54-7: 2000 at high and low sensitivity 550a/02 550a/02 550a/03 550a/04 550a/05 550d/01 Bases: B401 standard base B401DG deep base B401R standard base with schottky diode B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode B501 standard analogue detector base B501DG deep analogue detector base FL/B401 standard base FL/1000B standard base B501AP intelligent detector base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base BFA1 standard base Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Certificate No: 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 & CEA 4021: 2003 Multi Criteria Detectors Certificated Products 2351TEM ECO1002 FL/1002 20 Oct 2014 Conventional optical/thermal detector (B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases) Note: Meets the requirements of EN54-5:2000 at Class A1R and EN54-7:2000 at low, medium & high sensitivity settings. Conventional photo-thermal detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases) Note: Meets the requirements of EN 54-5:2000 at class A1R at pre-set sensitivity. Conventional optical/thermal detector base) Notes: Meets the requirements of EN54-5 at class A1R at pre-set sensitivity LPCB Ref. No. 550b/01 550b/02 550b/02 353 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 2251TEM 22051TLE-xx-yy 22051TE-xx-yy 2FA51T 22051TLEI-xx-yy 22051TEI-xx-yy LPCB Ref. No. Analogue optical/thermal smoke & heat detector (B501, B501DG and B5241EFT-1 bases) Notes : 1) Meets the requirements of EN 54-7: 2000 at sensitivity settings 1 to 5 2) Meets the requirements of EN 54-5: 2000 at Class A1R Analogue addressable photo-thermal-IR multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3)Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Conventional photo-thermal class A1R detector (BFA1 base) Note: Meets the requirements of EN54-5: 2000 class A1R at pre-set sensitivity Analogue addressable photo-thermal-IR multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R 550b/03 550b/04 550b/05 550b/06 550e/01 550e/02 Bases: B401 standard base B401DG deep base B401R standard base with schottky diode B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode B501 standard analogue detector base B501DG deep analogue detector base B5241EFT-1 analogue short circuit isolator base FL/B401 standard base FL/1000B standard base B501AP intelligent detector base B524HTR heater base B524RTE latching relay base BFA1 standard base 354 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 550c to EN 54-5: 2000 + A1: 2002 Certificate No: 550f to EN54-5: 2000 + A1: 2002 and EN 54-17: 2005 Heat Detectors Certificated Products 5351E 4351E ECO1005 FL/1005 5251EM 5251REM 52051RE-xx-yy 52051E-xx-yy 5FA51R 52051REI-xx-yy 52051EI-xx-yy Class A1R conventional rate of rise heat detector (B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases) Note: Meets the requirements of EN54-5:2000 at class A1R. Class BS conventional heat detector (B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases) Note: Meets the requirements of EN54-5:2000 at class BS. Conventional A1R rate-of-rise heat detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases) Conventional Class A1R rate of rise heat detector (FL/1000B base) Analogue addressable Class A1S fixed temperature heat detector (B501, B501DG and B5241EFT-1 bases) Analogue addressable Class A1R high temperature rate of rise heat detector (B501, B501DG and B5241EFT-1 bases) Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Analogue addressable class A1S fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Conventional A1R rate of rise heat detector (BFA1 base) Analogue addressable class A1R rate of rise heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White Analogue addressable class A1S fixed temperature heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol 2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White LPCB Ref. No. 550c/01 550c/02 550c/03 550c/03 550c/04 550c/05 550c/06 550c/07 550c/08 550f/01 550f/02 Bases: B401 standard base B401DG deep base B401R standard base with schottky diode B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode FL/B401 standard base FL/1000B standard base B501 standard analogue detector base B501AP intelligent detector base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base BFA1 Standard Base 20 Oct 2014 355 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Tanda Technologies (Singapore) Pte Ltd 217 Kallang Bahru, Multron Building, 339347, Singapore Tel: +63956866 E-mail: [email protected] Certificate No: 1148a-(cl-1) to EN 54-5: 2000 + A1: 2002 Heat Detectors Certificated Products DET-C632 Bases: DB-6 Conventional rate of rise & fixed temperature heat detector (DB-6 standard base) Note:Meets the requirements of EN 54-5 at Class A2R LPCB Ref. No. 1148a/01 Standard detector base Certificate No: 1148b-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products DET-C631 Bases: DB-6 Conventional optical smoke detector (DB-6 standard base) Note:Meets the requirements of EN 54-7 in the normal sensitivity setting. LPCB Ref. No. 1148b/01 Standard detector base Teledata S.r.l. Via Giulietti 8, Milan 20132, Italy Tel: +39 02-27201352 • Fax: +39 02-2593704 E-mail: [email protected] • Website: www.teledate-i.com Certificate No: 928a-(cl-6) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 928d-(cl-6) to EN 54-5: 2000 + A1: 2002 Point Heat Detectors Certificated Products SF3500 SF3500E Bases BS100 BS100E BS100/S BS100E/S Analogue addressable Class P heat detector with short circuit isolator (BS100, BS100E, BS100/S and BS100E/S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable Class P heat detector lite (BS100, BS100E, BS100/S and BS100E/S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 928a/01 928d/01 Universal adaptor base Vega adaptor base Universal adaptor base with shorting clip Vega adaptor base with shorting clip Certificate No: 928b-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 928e-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 928f-(cl-6) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003 356 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Point Smoke Detectors Certificated Products SF1000 Analogue addressable photoelectric smoke detector with short circuit isolator (BS100, BS100E, BS100/S and BS100E/S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable photoelectric smoke detector lite (BS100, BS100E, BS100/S and BS100E/S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable Class P heat and photoelectric smoke multi-sensor detector lite (BS100, BS100E, BS100/S and BS100E/S bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low SF1000E SF2000E Bases BS100 BS100E BS100/S BS100E/S LPCB Ref. No. 928b/01 928e/01 928f/01 Universal adaptor base Vega adaptor base Universal adaptor base with shorting clip Vega adaptor base with shorting clip Certificate No: 928c-(cl-6) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003 Multi-Criteria Detectors Certificated Products SF2000 20 Oct 2014 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (BS100, BS100E, BS100/S and BS100E/S bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 LPCB Ref. No. 928c/01 357 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. Optical only level 3 Optical only level 4 - Low Bases BS100 BS100E BS100/S BS100E/S Universal adaptor base Vega adaptor base Universal adaptor base with shorting clip Vega adaptor base with shorting clip Teletek Electronics JSC 14A Srebarna Street, Sofia 1407, Bulgaria Tel: +359 2 9694 700 • Fax: +359 2 9625 213 E-mail: [email protected] • Website: www.teletek-electronics.com Certificate No: 1139a to EN54-5: 2000 + A1: 2002 Heat Detectors Certificated Products T110 Analogue addressable class A1R heat detector (rate of rise and fixed temperature) (B124 base) LPCB Ref. No. 1139a/01 Base: B124 Standard analogue addressable detector base Certificate No: 1139b to EN54-7: 2000 + A1: 2002 + A2: 2006 Smoke Detectors Certificated Products S130 LPCB Ref. No. 1139b/01 Analogue addressable optical smoke detector (B124 base) Base: B124 Standard analogue addressable detector base Certificate No: 1139c to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Multi-Sensor/Multi-Criteria Detectors Certificated Products M140 Analogue addressable combined class A1R heat and optical smoke detector (B124 base) LPCB Ref. No. 1139c/01 Base: B124 Standard analogue addressable detector base Thorn Security Limited, trading as Tyco Safety Products Dunhams Lane, Letchworth SG6 1BD, United Kingdom Tel: +44 (0)1462 667700 • Fax: +44 (0)1462 667777 E-mail: [email protected] • Website: www.tycosafetyproducts-europe.com Certificate No: 681c-(cl-1) to EN 54-5: 2000 + A1: 2002 Certificate No: 681p-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Heat Detectors Certificated Products 801H 358 MX Digital addressable Class P heat detector (4B, 4B-I and 5B bases) Note: 1. Meets EN54 Part 5 for classes A1R, A2S and CR. LPCB Ref. No. 681c/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 601H-R 601H-F MD601Ex MD611Ex 816H 611H-F 631H-F 840H 830H 850H (516.850.053) 850H (516.850.053.E) Simplex (4098-6253) Conventional Class A1R heat detector (4B, 4B-D and 5B bases) Conventional Class A1S heat detector (4B, 4B-D and 5B bases) Conventional intrinsically safe Class A1R rate of rise heat detector (MUBEx base, 5BEx bases) Conventional intrinsically safe Class A1S fixed temperature heat detector (MUBEx base, 5BEx base) MX Digital addressable Class P heat detector (4B, 4B-I and 5B bases) Note: 1. Meets EN54 Part 5 for classes A1R, A2S and CR. Conventional Class A1S fixed temperature heat detector (4B, 4B-D and 5B base) Conventional Class CS fixed temperature heat detector (4B, 4B-D and 5B base) MX digital addressable Class P heat detector (4B, 4B-I, and 5B bases) Note: 1. Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - Heat detector at Class CR MX digital addressable Class P heat detector (4B, 4B-I, and 5B bases) Note: 1. Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - Heat detector at Class CR MX digital addressable Class P heat detector (4B, 4B-C, and 5B bases) Note: 1. Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - Heat detector at Class CR MX Digital Addressable Class P Heat Detector with Short Circuit Isolator (4B, 4B-C and 5B bases) Note: Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - Heat detector at Class CR MX Digital Addressable Class P Heat Detector with Short Circuit Isolator (4B, 4B-C and 5B bases) Note: Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - Heat detector at Class CR LPCB Ref. No. 681c/02 681c/03 681c/04 681c/05 681c/06 681c/07 681c/08 681c/09 681c/10 681p/01 681p/01 681p/01 Bases: 4B 4" universal mounting base 4B-C, 4” continuity base 4B-D 4" diode mounting base 4B-I, 4” isolator base 5B 5” Universal mounting base 5BEX Intrinsically safe detector base MUBEx Intrinsically safe detector base Certificate No: 681j-(cl-1) to EN 54-7: 2000 + AI: 2002 + A2: 2006 and CEA4021: 1999 Certificate No: 681b-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA4021: 2003 Certificate No: 681a-(cl-1) to EN 54-5: 2000 + A1: 2002 and Test Schedule 68297/29.0 Test schedule for Carbon Monoxide Fire Detectors Certificate No: 681e-(cl-1) to EN 54-5: 2000 + A1: 2002 and LPS1265 Iss.1.0 Certificate No: 681w-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA4021: 2003 Multi-criteria Detectors Certificated Products 801CH 20 Oct 2014 MX Digital addressable Carbon Monoxide and Class P heat detector (4B and 5B bases) Notes: Approved with the following mode configurations:- LPCB Ref. No. 681a/01 359 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. 1. Carbon monoxide detector at High and Normal sensitivity 2. Rate of rise heat detector at Class A1R 3. Fixed temperature heat detector at Class A2S 4. Heat enhanced carbon monoxide fire detector at High and Normal sensitivity 5. Heat enhanced carbon monoxide fire detector at High and Normal sensitivity and rate of rise heat detector at Class A1R 801PH Conditions of approval: 1. The 801CH should only be installed in accordance with the manufacturers recommendations. 2. The 801CH should not be set only as a carbon monoxide fire detector where there is a specific risk of rapid burning / flaming fires. 3. Refer to technical publication 17A-02-DET for limitations on the use of carbon monoxide fire detection. MX digital addressable photoelectric smoke and Class P heat detector (4B, 4B-I and 5B Bases) 681b/01 Note: Approved with the following mode configurations:1. Optical smoke detector at High and Normal sensitivity 2. Rate of rise heat detector at Class A1R 3. Fixed temperature heat detector at Class A2S 4. Heat enhanced optical smoke detector at High and Normal sensitivity 5. Optical smoke detector using FastLogic at High and Normal sensitivity 6. Heat enhanced optical smoke detector using FastLogic at High and Normal sensitivity 840PC 830PC 840PH 830PH 601CH 601PH MR601Tex 360 MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide detector (4B, 4B-I, and 5B bases) Notes: 1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector - RESIL Resilient optical smoke and A2S heat multi-criteria detector - Heat detector at Class A1R - HPO Heat enhanced optical smoke detector at Normal sensitivity 2. The Carbon Monoxide toxic gas/CCO modes are not approved MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide detector (4B, 4B-I, and 5B bases) Notes: 1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector - RESIL Resilient optical smoke and A2S heat multi-criteria detector - Heat detector at Class A1R - HPO Heat enhanced optical smoke detector at Normal sensitivity 2. The Carbon Monoxide toxic gas/CCO modes are not approved MX digital addressable photoelectric smoke and Class P heat detector (4B, 4B-I, and 5B bases) Note: Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic - HPO Heat enhanced optical smoke at High, Normal and Low sensitivity - FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using FastLogic. MX digital addressable photoelectric smoke and Class P heat detector (4B, 4B-I, and 5B bases) Note: Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic - HPO Heat enhanced optical smoke at High, Normal and Low sensitivity - FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using FastLogic. Conventional Class A1R thermally enhanced Carbon Monoxide detector (4B, 4B-D and 5B Bases) Conventional high performance photoelectric smoke detector (4B, 4B-D and 5B bases) Conventional intrinsically safe high performance photoelectric smoke detector with heat enhancement (MUBEx base, 5BEx bases) 681b/02 681b/03 681b/04 681b/05 681e/01 681j/01 681j/02 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 816PH 850PC (516.850.054) 850PC (516.850.054.E) Simplex (4098-6254) 851PCN 850PH (516.850.051) 850PH (516.850.051.E) Simplex (4098.6251) 20 Oct 2014 MX Digital addressable photoelectric detector with heat enhancement (4B and 5B bases) Note: 1. Meets EN54 Part 7 at Normal sensitivity MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide detector with short circuit isolator (4B, 4B-C and 5B bases) Notes: 1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector - RESIL Resilient optical smoke and A2S heat multi-criteria detector - Heat detector at Class A1R - HPO Heat enhanced optical smoke detector at Normal sensitivity 2. The Carbon Monoxide toxic gas/CCO modes are not approved MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide detector with short circuit isolator (4B, 4B-C and 5B bases) Notes: 1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector - RESIL Resilient optical smoke and A2S heat multi-criteria detector - Heat detector at Class A1R - HPO Heat enhanced optical smoke detector at normal sensitivity 2. The Carbon Monoxide toxic gas/CCO modes are not approved MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide detector with short circuit isolator (4B, 4B-C and 5B bases) Notes: 1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector - RESIL Resilient optical smoke and A2S heat multi-criteria detector - Heat detector at Class A1R - HPO Heat enhanced optical smoke detector at normal sensitivity 2. The Carbon Monoxide toxic gas/CCO modes are not approved MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide detector with short circuit isolator [Ex(N) version] (4B-EN base) Notes: 1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector - RESIL Resilient optical smoke and A2S heat multi-criteria detector - Heat detector at Class A1R - HPO Heat enhanced optical smoke detector at Normal sensitivity 2. The Carbon Monoxide toxic gas/CCO modes are not approved MX digital addressable photoelectric smoke and Class P heat detector with short circuit isolator (4B, 4B-C, and 5B bases) Note: Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic - HPO Heat enhanced optical smoke at High, Normal and Low sensitivity - FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using FastLogic. MX digital addressable photoelectric smoke and Class P heat detector with short circuit isolator (4B, 4B-C, and 5B bases) Note: 1. Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic - HPO Heat enhanced optical smoke at High, Normal and Low sensitivity - FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using FastLogic. MX digital addressable photoelectric smoke and Class P heat detector with short circuit isolator (4B, 4B-C, and 5B bases) Note: 1. Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic - HPO Heat enhanced optical smoke at High, Normal and Low sensitivity - FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using LPCB Ref. No. 681j/03 681w/01 681w/01 681w/01 681w/02 681w/03 681w/03 681w/03 361 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products 851PH 851PHN LPCB Ref. No. FastLogic. MX digital addressable photoelectric smoke and Class P heat detector with short circuit isolator [Marine version] (4B, 4B-C, and 5B bases) Note: 1. Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic - HPO Heat enhanced optical smoke at High, Normal and Low sensitivity - FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using FastLogic. MX digital addressable photoelectric smoke and Class P heat detector with short circuit isolator [Ex(N) version] (4B-EN base) Note: 1. Approved with the following mode configurations:- Heat detector at Class A1R - Heat detector at Class A2S - OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic - HPO Heat enhanced optical smoke at High, Normal and Low sensitivity - FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using FastLogic. 681w/04 681w/05 Bases: 4B 4” universal mounting base 4B-C 4” continuity base 4B-D Diode mounting base 4B-D 4" Diode mounting base 4B-EN 4” Ex{N} compliant mounting base 4B-I, 4” isolator base 5B 5” Universal mounting base 5BEx Intrinsically safe mounting base MUB Universal mounting base MUBEx intrinsically safe detector base DHM-5B - Deck head mounting adaptor for 5" base Certificate No: 763a to EN 54-10: 2002 Certificate No: 681r-(cl-1) to EN 54-10: 2002 + A1: 2005 Certificate No: 018e-(cl-1) to EN 54-10: 2001+ A1:2005 Flame Detectors Certificated Products S231i+ S231f+ S241i+ S241f+ S251i+ S251f+ S261f+ S271f+ S271i+ 601F 601FEx 801F 801FEx S231i+ S231f+ S241i+ S241f+ S251i+ S251f+ S261f+ S271f+ S271i+ S231i+ S231f+ S241i+ 362 Class 1, conventional 2-wire intrinsically safe IR flame detector Class 1, conventional 2-wire flame proof IR flame detector Class 1, 4-20mA intrinsically safe IR flame detector Class 1, 4-20mA flame proof IR flame detector Class 1, analogue addressable intrinsically safe IR flame detector Class 1, analogue addressable flame proof IR flame detector Class 1, relay flame proof IR flame detector Class 1, analogue addressable intrinsically safe triple IR flame detector with MX interface Class 1, analogue addressable flame proof triple IR flame detector with MX interface Conventional Class 2 flame detector (4B, 4B-D and 5B bases) Conventional Class 2 intrinsically safe flame detector (MUBEx and 5BEx bases) MX addressable Class 2 flame detector (4B and 5B bases) MX addressable Class 2 intrinsically safe flame detector (MUBEx and 5BEx bases) Class 1, Conventional 2-Wire Intrinsically Safe IR Flame Detector Class 1, Conventional 2-Wire Flame Proof IR Flame Detector Class 1, 4-20mA Intrinsically Safe IR Flame Detector Class 1, 4-20mA Flame Proof IR Flame Detector Class 1, Analogue Addressable Intrinsically Safe IR Flame Detector Class 1, Analogue Addressable Flame Proof IR Flame Detector Class 1, Relay Flame Proof IR Flame Detector Class 1, Analogue Addressable Intrinsically Safe Triple IR Flame Detector with MX Interface Class 1, Analogue Addressable Flame Proof Triple IR Flame Detector with MX Interface Conventional class 1 2-wire intrinsically safe IR flame detector Conventional class 1 2-wire flame proof IR flame detector 4-20mA current class 1 intrinsically safe IR flame detector LPCB Ref. No. 018e/01 018e/02 018e/03 018e/04 018e/05 018e/06 018e/07 018e/08 018e/09 681r/01 681r/02 681r/03 681r/04 681r/05 681r/06 681r/07 681r/08 681r/09 681r/10 681r/11 681r/12 681r/13 763a/01 763a/02 763a/03 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products S241f+ S251i+ S251f+ S261f+ S271i+ S271f+ 4-20mA current class 1 flame proof IR flame detector Analogue addressable class 1 intrinsically safe IR flame detector Analogue addressable class 1 flame proof IR flame detector Relay class 1 flame proof IR flame detector Analogue class 1 triple IR flame detector with MX interface Analogue class 1 flame proof triple IR flame detector with MX interface LPCB Ref. No. 763a/04 763a/05 763a/06 763a/07 763a/08 763a/09 Bases: 4B 4” standard mounting base 4B-D 4” diode mounting base 5B standard mounting base MUBEx Intrinsically safe mounting base 5BEx Intrinsically safe mounting base MUB standard mounting base 5B standard mounting base 5BI addressable isolator base Certificate No: 681d-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 681z-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Smoke Detectors Certificated Products 801I 601I 601P 816P 840P 830P 850P (516.850.052) 850P (516.850.052.E) Simplex (4098-6252) MX Digital addressable ionisation smoke detector (4B, 4B-I and 5B bases) Note: 1. Meets EN54 Part 7 at High and Normal Sensitivity Conventional ionisation smoke detector (4B, 4B-D and 5B bases) Conventional optical smoke detector (4B, 4B-D and 5B bases) MX Digital addressable photoelectric smoke detector (4B, 4B-I and 5B bases) Note: 1. Meets EN54 Part 7 at High and Normal Sensitivity MX digital addressable photoelectric smoke detector (4B, 4B-I, and 5B bases) Note: 1. Approved with the following mode configurations:- OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic MX digital addressable photoelectric smoke detector (4B, 4B-I, and 5B bases) Note: 1. Approved with the following mode configurations:- OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic MX digital addressable photoelectric smoke detector with short circuit isolator (4B, 4B-C and 5B bases) Note: 1. Approved with the following mode configurations:- OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic MX digital addressable photoelectric smoke detector with short circuit isolator (4B, 4B-C and 5B bases) Note: Approved with the following mode configurations:- OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic MX digital addressable photoelectric smoke detector with short circuit isolator (4B, 4B-C and 5B bases) Note: Approved with the following mode configurations:- OPT Optical smoke detector at High, Normal and Low sensitivity - FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic LPCB Ref. No. 681d/01 681d/02 681d/03 681d/05 681d/06 681d/07 681z/01 681z/01 681z/01 Bases: 4B 4" universal mounting base 4B-C, 4” continuity base 4B-D Diode mounting base 4B-I, 4” isolator base 5B 5” Universal mounting base 20 Oct 2014 363 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificate No: 681aa-(cl-1) to EN 54-17: 2005 Isolating base Certificated Products 4B-I LPCB Ref. No. 681aa/01 Short circuit isolator base UniPOS Ltd 47 San Stefano Street, Pleven, Bulgaria Tel: +359 64 891124 E-mail: [email protected] • Website: www.unipos-bg.com Certificate No: 1107a to EN 54-5: 2000 A1: 2002 Certificated Products FD7120 FD8020 LPCB Ref. No. 1107a/01 Analogue addressable rate of rise heat detector (7100 base) Note: Meets the requirements of EN 54-5 at Class A2R Conventional rate-of-rise heat detector (8000 base) Note: Meets the requirements of EN 54-5 at Class A2R 1107a/02 Bases 7100 standard analogue detector base 8000 standard conventional detector base Certificate No: 1107b to EN 54-7: 2001 + A1: 2002 + A2: 2006 Certificated Products FD7130 FD8030 LPCB Ref. No. 1107b/01 Analogue addressable optical smoke detector (7100 base) Note: Meets the requirements of EN 54-7 in the normal sensitivity setting. Conventional optical smoke detector (8000 base) Note: Meets the requirements of EN 54-7 in the normal sensitivity setting. 1107b/02 Bases 7100 standard analogue detector base 8000 standard conventional detector base Certificate No: 1107c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2001 + A1: 2002 + A2: 2006 & CEA 4021: July 2003 Certificated Products FD7160 FD8060 Analogue addressable combined heat & optical smoke detector (7100 base) Note: Meets the requirements of EN 54-5: 2000 (Class A2R) & EN54-7: 2000 at default normal sensitivity setting. Conventional combined heat & optical smoke detector (8000 base) Note: Meets the requirements of EN 54-5: 2000 (Class A2R) & EN54-7: 2000 at default normal sensitivity setting. LPCB Ref. No. 1107c/01 1107c/02 Bases 7100 standard analogue detector base 8000 standard conventional detector base 364 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS UTC Fire & Security BV Kelvinstraat 7, NL-6003DH, Weert, The Netherlands Tel: + 31 495 58 30 00 • Fax: + 31 495 55 00 42 E-mail: Daragh.O'[email protected] • Website: www.utcfireandsecurity.com Certificate No: 092p-(cl-1) to EN 54-5: 2000 + A1: 2002 Certificated Products EA20E-3 Analogue addressable Class P heat detector (ZP7-SB1 base) (Labelled EST) Note: 1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only. Analogue addressable Class P heat detector (ZP7-SB1 base) (Labelled Photain Controls) Note: 1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only. Analogue addressable Class P heat detector (ZP7-SB1 base) (Labelled Plana Fabrega) Note: 1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only. Analogue addressable Class P heat detector (ZP7-SB1 base) (Labelled Ziton) Note: 1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only. Conventional Class A1 heat detector (E6-BS1 base) (Labelled EST) Conventional Class A1 heat detector (Z6-BS1 & Z6-BS5 bases) (Labelled Ziton) Conventional fixed temperature heat detector, Polar white, (Class A1) & Z6-BS5-P bases) (Labelled Ziton) Conventional Class A1R heat detector (E6-BS1 base) (Labelled EST) Conventional Class A1R heat detector (FSBP2000 base) (Labelled Photain Controls) Conventional Class A1R heat detector (BD-21 & BD-22 bases) (Labelled Plana Fabrega) Conventional Class A1R heat detector (Z6-BS1 & Z6-BS5 bases) (Labelled Ziton) Conventional rate of rise heat detector, Polar white, (Class A1R) & Z6-BS5-P bases) (Labelled Ziton) Conventional Class B heat detector (E6-BS1 base) (Labelled EST) Conventional Class B heat detector (FSBP2000 base) (Labelled Photain Controls) Conventional Class B heat detector (Z6-BS1 & Z6-BS5 bases) (Labelled Ziton) Conventional high temperature heat detector, Polar white, (Class B) & Z6-BS5-P bases) (Labelled Ziton) PRRPHDI2004 T-17003 ZP720-3 E620-581-3 Z620-581-3 Z620-581-3P E620-582-3 PRRP2004 TV-7003 Z620-582-3 Z620-582-3P E620-771-3 PHDP2004HT Z620-771-3 Z620-771-3P Bases ZP7-SB1 Z6-BS1 E6-BS1 BD-21 FSBP2000 Z6-BS5 BD-22 Z6-BS1-P Z6-BS5-P LPCB Ref. No. 092p/01 092p/01 092p/01 092p/01 092p/02 092p/02 092p/02 092p/03 092p/03 092p/03 092p/03 092p/03 092p/04 092p/04 092p/04 092p/04 Standard base Conventional surface base Conventional surface base Conventional surface base Conventional surface base Conventional diode base Conventional diode base Polar white conventional surface base Polar white conventional diode base Certificate No: 092n-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificated Products EA10E-2 20 Oct 2014 Analogue addressable ionisation smoke detector (ZP7-SB1 base) (Labelled EST) LPCB Ref. No. 092n/01 365 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable ionisation smoke detector (ZP7-SB1 base) (Labelled Plana Fabrega) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable ionisation smoke detector (ZP7-SB1 base) (Labelled Photain Controls) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable ionisation smoke detector (ZP7-SB1 base) (Labelled Ziton) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable photoelectric smoke detector (ZP7-SB1 base) (Labelled EST) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable photoelectric smoke detector (ZP7-SB1 base) (Labelled Plana Fabrega) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable photoelectric smoke detector (ZP7-SB1 base) (Labelled Photain Controls) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable photoelectric smoke detector (ZP7-SB1 base) (Labelled Ziton) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable optical smoke sensor, (ZP7-SB1-P base) (Labelled Ziton with Chubb logo) Note: Approved for use at Standard sensitivity setting only. I-17001 ISDI2000 ZP710-2 EA30E-2 O-17002 PPDI2000 ZP730-2 ZP730-2S30 E610-3 Conventional ionisation smoke detector (E6-BS1 base) (Labelled EST) Conventional ionisation smoke detector (Z6-BS1 & Z6-BS5 bases) (Labelled Ziton) Conventional photoelectric smoke detector (E6-BS1 base) (Labelled EST) Conventional photoelectric smoke detector (BD-21 & BD-22 bases) (Labelled Plana Fabrega) Conventional photoelectric smoke detector (FSBP2000 base) (Labelled Photain Controls) Conventional photoelectric smoke detector (Z6-BS1 & Z6-BS5 bases) (Labelled Ziton) Conventional optical smoke detector, Polar white & Z6-BS5-P bases) (Labelled Ziton) Conventional optical smoke detector, Polar white, Chubb & Z6-BS5 basesZiton with Chubb logo) Z610-3 E630-3 O-7002 PPDP2004 Z630-3 Z630-3P Z630-3S30 Bases ZP7-SB1 Z6-BS1 E6-BS1 BD-21 FSBP2000 Z6-BS5 BD-22 Z6-BS1-P Z6-BS5-P LPCB Ref. No. 092n/01 092n/01 092n/01 092n/02 092n/02 092n/02 092n/02 092n/02 092n/03 092n/03 092n/04 092n/04 092n/04 092n/04 092n/04 092n/04 Standard base Conventional surface base Conventional surface base Conventional surface base Conventional surface base Conventional diode base Conventional diode base Polar white conventional surface base Polar white conventional diode base Certificate No: 092k-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Certificated Products EA32E-2 366 Analogue addressable combined photoelectric smoke and heat detector. (Labelled EST) (ASBE-2 base) Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7and sensitivity profiles LPCB Ref. No. 092k/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. 5 (A1) and 6(A2) for EN 54:5. Analogue addressable combined photoelectric smoke and heat detector. (Labelled EEC) (ZP7-SB1 base) Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7 and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5. Analogue addressable combined photoelectric smoke and heat detector. (Labelled Plana Fabrega) (ZP7-SB1 base) Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7 and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5. Analogue addressable combined photoelectric smoke and heat detector. (Labelled Photain Controls) (ZP7-SB1 base) Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5. Analogue addressable combined photoelectric smoke and heat detector. (Labelled Ziton) (ZP7-SB1 base) Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7and sensitivity profiles EAS707 OT-17004 PPDPHDI2000 ZP732-2 5 (A1) and 6(A2) for EN 54:5. Analogue addressable combination smoke and heat detector, (Labelled Ziton with Chubb logo) (ZP7-SB1-P base) Note : Certificated at sensitivity profiles 1-4 for EN 54:7 and sensitivity profiles ZP732-2S30 092k/01 092k/01 092k/01 092k/01 092k/01 5 (A1) and 6 (A2) for EN 54:5. Bases ZP7-SB1 Standard base ASBE-2 Standard base UTC Fire & Security Inc. Trading as Edwards Systems Technology 129 North Main Street, Pittsfield, Maine 04967, USA Tel: 941 739-42228 Website: www.fs.utc.com Certificate No: 262s-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Multi-Criteria Detectors Certificated Products SIGA-IPHSI SIGA-PHSI Bases: SIGI-IBS SIGA-SB SIGA-SB4 SIGA-RB 20 Oct 2014 Intelligent analogue addressable thermally enhanced photoelectric and ionisation smoke detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4 & SIGA-AB4G bases) Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases Intelligent analogue addressable thermally enhanced photoelectric smoke detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4 and SIGA-AB4G bases) Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases LPCB Ref. No. 262s/01 262s/02 Isolator base Standard base Standard base with trim skirt Relay base 367 PART 1: SECTION 4.1 COMMERCIAL DETECTORS SIGA-RB4 SIGA-IB SIGA-IB4 SIGA-AB4G Relay base with trim skirt Isolator Base Isolator base with 4 inch mounting adaptors Sounder base Accessories: SIGA-LED Indicator Certificate No: 262t-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products SIGA-PSI Intelligent analogue addressable photoelectric smoke detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4 and SIGA-AB4G bases) Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases Bases: SIGI-IBS SIGA-SB SIGA-SB4 SIGA-RB SIGA-RB4 SIGA-IB SIGA-IB4 SIGA-AB4G Isolator base Standard base Standard base with trim skirt Relay base Relay base with trim skirt Isolator Base Isolator base with 4 inch mounting adaptors Sounder base Accessories: SIGA-LED Indicator LPCB Ref. No. 262t/02 Certificate No: 262u-(cl-1) to EN 54-5: 2000 + A1: 2002. Point Heat Detectors Certificated Products SIGA-HRSI Intelligent analogue addressable Class A1 & A2R rate of rise heat detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB, SIGA-IB4 and SIGA-AB4G bases) Note: 1. The SIGA-LED indicator is also approved for use with the SIGA-SB and SIGA-SB4 bases Bases: SIGI-IBS SIGA-SB SIGA-SB4 SIGA-RB SIGA-RB4 SIGA-IB SIGA-IB4 SIGA-AB4G Isolator base Standard base Standard base with trim skirt Relay base Relay base with trim skirt Isolator Base Isolator base with 4 inch mounting adaptors Sounder base Accessories: SIGA-LED Indicator 368 LPCB Ref. No. 262u/02 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS VRC Terofire Products Lion House, Lion Street, Congleton, Cheshire CW12 4BH, United Kingdom Tel: +44 (0)1260 297578 • Fax: +44 (0)1260 290078 E-mail: [email protected] Certificate No: 512d to EN 54-5: 2000 + A1: 2002 Point Heat Detectors Certificated Products 10-0003 10-0003 Conventional 2 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base) Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base) LPCB Ref. No. 512d/03 512d/04 Bases: P/N854001 4-Wire detector base Certificate No: 512a to EN 54-7: 2000 + A1: 2002 + A2: 2006 Point Smoke Detectors Certificated Products 10-0001 Conventional 2 wire photoelectric smoke detector with remote LED output (P/N854001 base) LPCB Ref. No. 512a/02 Base P/N854001 4-Wire detector base Certificate No: 512b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Multi-Criteria Detectors Certificated Products 10-0002 Conventional 2 wire photoelectric smoke and heat detector with remote LED output (P/N854001 base) LPCB Ref. No. 512b/02 Base P/N854001 4-Wire detector base Wagner Group GmbH Schleswigstraße 5, D-30853 Langenhagen, Germany Tel: +49 511 97383 0 • Fax: +49 511 73338 6 E-mail: [email protected] • Website: www.wagner.de Certificate No: 524c to EN 54-20: 2006 Aspirating Smoke Detectors Certificated Products LPCB Ref. No. 524c/01 TITANUS PRO-SENS Notes: 1. Approval of the detector is conditional upon the following requirements: For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and 20 Oct 2014 369 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. design software TF-SC-1. The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131. 2. Approved detector configurations (Class A, Class B and Class C): TP-1/a (standard version, no bargraph display, 1 alarm, not available for networking) TP-1-F/a (deep freeze version, no bargraph display, 1 alarm, not available for networking ) TP-1-SL (silent version, no bargraph display, 1 alarm, not available for networking) 3. The approved detector must incorporate one or two of the following detector modules: DM-TP-01-L (standard version, sensitivity of 0.015%/m) DM-TP-01-L-F (deep freeze version, sensitivity of 0.015%/m) DM-TP-10-L (standard version, sensitivity of 0.10%/m) DM-TP-10-L-F (deep freeze version, sensitivity of 0.10%/m) DM-TP-50-L (standard version, sensitivity of 0.50%/m) DM-TP-50-L-F (deep freeze version, sensitivity of 0.50%/m) TITANUS PRO-SENS/net 524c/02 Notes: 1. Approval of the detector is conditional upon the following requirements: For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1. The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131. 2. Approved detector configurations (Class A, Class B and Class C): TP-3 (standard version, no bargraph display, 1 alarm, prepared for networking) TP-3-F (deep freeze version, no bargraph display, 1 alarm, prepared for networking) TP-3-SL (silent version, no bargraph display, 1 alarm, prepared for networking) TP-4 (standard version, no bargraph display, 2 alarms, prepared for networking) TP-4-F (deep freeze version, no bargraph display, 2 alarms, prepared for networking) TP-4-SL (silent version, no bargraph display, 2 alarms, prepared for networking) TP-5 (standard version, no bargraph display, 3 alarms, prepared for networking) TP-5-F (deep freeze version, no bargraph display, 3 alarms, prepared for networking) TP-5-SL (silent version, no bargraph display, 3 alarms, prepared for networking) 3 The approved detector must incorporate one or two of the following detector modules: DM-TT-01-L (standard version, sensitivity of 0.015%/m) DM-TT-01-L-F (deep freeze version, sensitivity of 0.015%/m) DM-TT-10-L (standard version, sensitivity of 0.10%/m) DM-TT-10-L-F (deep freeze version, sensitivity of 0.10%/m) DM-TT-50-L (standard version, sensitivity of 0.50%/m) DM-TT-50-L-F (deep freeze version, sensitivity of 0.50%/m) TITANUS TOP-SENS 524c/03 Notes: 1. Approval of the detector is conditional upon the following requirements: For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1. The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131. 370 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. 2. Approved detector configurations (Class A, Class B and Class C): TT-1/a (standard version, bargraph display, 3 alarms, prepared for networking) TT-1-F/a (deep freeze version, bargraph display, 3 alarms, prepared for networking) TT-1-SL (silent version, bargraph display, 3 alarms, prepared for networking) 3. The approved detector must incorporate one or two of the following detector modules: DM-TT-01-L (standard version, sensitivity of 0.015%/m) DM-TT-01-L-F (deep freeze version, sensitivity of 0.015%/m) DM-TT-10-L (standard version, sensitivity of 0.10%/m) DM-TT-10-L-F (deep freeze version, sensitivity of 0.10%/m) DM-TT-50-L (standard version, sensitivity of 0.50%/m) DM-TT-50-L-F (deep freeze version, sensitivity of 0.50%/m) TITANUS MICRO-SENS 524c/04 Notes: 1. Approval of the detector is conditional upon the following requirements: For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1. The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131. 20 Oct 2014 2. Approved detector configurations, sensitivity of 0.10%/m (Class A, Class B and Class C): DM-TM-10 (standard version) DM-TM-R-10 (version with ROOM IDENT) DM-TM-B-10 (version with bargraph display) DM-TM-RB-10 (version with ROOM IDENT, bargraph display) DM-TM-Z-10 (version with redundancy fan) DM-TM-ZB-10 (version with redundancy fan, bargraph display) DM-TM-10-F (deep freeze version) DM-TM-B-10-F (version with bargraph display, deep freeze) DM-TMV-10 (version with 2 stages of alarm) DM-TMV-R-10 (version with 2 stages of alarm, ROOM IDENT) DM-TMV-B-10 (version with 2 stages of alarm, bargraph display) DM-TMV-RB-10 (version with 2 stages of alarm, ROOM IDENT, bargraph display) DM-TMV-10-F (version with 2 stages of alarm, deep freeze) DM-TMV-B-10-F (version with 2 stages of alarm, bargraph display, deep freeze) DM-MB-TM-10 (version without fan to be used as detector box) DM-MB-TM-B-10 (version without fan to be used as detector box, bargraph display) 3. Approved detector configurations, sensitivity of 0.50%/m (Class A, Class B and Class C): DM-TM-50 (standard version) DM-TM-R-50 (version with ROOM IDENT) DM-TM-B-50 (version with bargraph display) DM-TM-RB-50 (version with ROOM IDENT, bargraph display) DM-TM-Z-50 (version with redundancy fan) DM-TM-ZB-50 (version with redundancy fan, bargraph display) DM-TM-50-F (deep freeze version) DM-TM-B-50-F (version with bargraph display, deep freeze) DM-TMV-50 (version with 2 stages of alarm) DM-TMV-R-50 (version with 2 stages of alarm, ROOM IDENT) DM-TMV-B-50 (version with 2 stages of alarm, bargraph display) DM-TMV-RB-50 (version with 2 stages of alarm, ROOM IDENT, bargraph display) DM-TMV-50-F (version with 2 stages of alarm, deep freeze) DM-TMV-B-50-F (version with 2 stages of alarm, bargraph display, deep freeze) DM-MB-TM-50 (version without fan to be used as detector box) DM-MB-TM-B-50 (version without fan to be used as detector box, bargraph display) 371 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. TITANUS RACK-SENS 524c/05 Notes: 1. Approval of the detector is conditional upon the following requirements: For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1. The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131. 2. Approved detector configurations (Class A, Class B and Class C): TR1-10 (placed in a ‘1U’ housing, sensitivity of 0.10%/m) TR1-50 (placed in a ‘1U’ housing, sensitivity of 0.50%/m) TR2-10 (placed in a ‘2U’ housing, sensitivity of 0.10%/m) TR2-50 (placed in a ‘2U’ housing, sensitivity of 0.50%/m) Xtralis Pty Limited 4 North Drive, Virginia Park, 236-262 East Boundary Road, East Bentleigh, Victoria 3165, Australia Tel: +61 3 9936 7001, +44 (0)1442 242330 • Fax: +61 3 9936 7201 E-mail: [email protected] • Website: www.xtralis.com European Operations at: Xtralis (UK) Limited, Vision House, Focus 31, Mark Road, Hemel Hempstead, Hertfordshire HP2 7BW, United Kingdom Tel: +44 (0)1442 242330 • Fax: +44 (0)1442 249327 Certificate No: 305e to EN 54-20: 2006 Certificate No: 305d to EN 54-20: 2006 Certificate No: 305g to EN 54-20: 2006 Aspirating Smoke Detectors Certificated Products VESDA VLF-250-xx (VLF250-01NF*) high sensitivity aspirating smoke detector 372 Incorporating the following ancillary equipment: VIC-010 VESDAnet network card VIC-020 Multifunction control card VIC-030 Multifunction control card VRT-V00 Remote VLF display (with 7 relays) VRT-W00 Remote VLF display (no relays) VRT-500 Remote relay unit (with 7 relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide (07208). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. xx denotes alternative language version where xx (range 00 to 99) designates the language of the product labels. 7. Alternative model number with suffix* as indicated, intended for French market. 8. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be LPCB Ref. No. 305d/01 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products VESDA VLF-500-xx (VLF500-01NF*) high sensitivity aspirating smoke detector VESDA VLC High sensitivity aspirating smoke detector VESDA VLP High sensitivity aspirating smoke detector 20 Oct 2014 LPCB Ref. No. sought and the recommendations followed. Incorporating the following ancillary equipment: VIC-010 VESDAnet network card VIC-020 Multifunction control card VIC-030 Multifunction control card VRT-V00 Remote VLF display (with 7 relays) VRT-W00 Remote VLF display (no relays) VRT-500 Remote relay unit (with 7 relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide (07209). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. xx denotes alternative language version where xx (range 00 to 99) designates the language of the product labels. 7. Alternative model number with suffix* as indicated, intended for French market. 8. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Approved configurations: - VLC-500 (VLF-50000-NF*) VLC Relays only (RO) version - VLC-505 (VLF-50500-NF*) VLC VESDAnet (VN) version - VLC-400 (VLF-400-NF*) VLC Apollo (AP) version - VLC-700 (801519.F0*) VLC Esser (EB) version - VLC-800 (VLF-800-NF*) VLC Tyco (MX) version Approved remote units with the VLC-505 VESDAnet (VN) version: - VRT-J00 Remote VLC display (with 7 relays) - VRT-K00 Remote VLC display (no relays) - VRT-500 Remote relay unit (with 7 relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLC product guides (10280 [VLC-500 & VLC-505], 03494 [VLC-400], 09411 [VLC-700], 09515 [VLC-800]). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. Alternative model numbers with suffix* as indicated, intended for French market. 7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Approved Configurations: VLP-012 (VLP-01200-NF*) VLP detector with Display & Programmer VLP-002 (VLP-00200-NF*) VLP detector with Display VLP-400 (VLP-00000-NF*) VLP detector with Fire/OK LEDs only VLP-401 (VLP-00100-NF*) VLP detector with Programmer & Fire/OK LEDs VLP-100 VLP detector with OEM cover Approved remote units: VRT-100 Remote Programmer VRT-200 Remote VLP Display unit (with 7 relays) VRT-300 VESDAnet socket VRT-500 Remote Relay unit (with 7 relays) VRT-600 Remote VLP Display unit (without relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied 305d/02 305d/03 305d/04 373 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. with power from a power supply conforming to the requirements of EN 54-4. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLP product guide (10278). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. Alternative model numbers with suffix* as indicated, intended for French market. 7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Approved Configurations: VLS-600 (VLS-20000-NF*) VLS with 7 relays and Fire/OK LEDs VLS-204 (VLS-20400-NF*) VLS with 7 Relays and Display Module VLS-214 (VLS-21400-NF*) VLS with 7 Relays, Display and Program Module VLS-700 (VLS-30000-NF*) VLS with 12 relays and Fire/OK LEDs VLS-304 (VLS-30400-NF*) VLS with 12 Relays and Display Module VLS-314 (VLS-31400-NF*) VLS with 12 Relays, Display and Program Module VLS-100 VLS with 7 Relays and OEM cover VLS-500 VLS with 12 Relays and OEM cover Approved Remote Units: VRT-400 Remote Scanner Display with 7 relays VRT-700 Remote Scanner Display with no relays VRT-800 Remote Scanner Display with 12 relays VRT-900 Remote Scanner Relays -12 relays VRT-E00 Remote Scanner Relays - 7 relays Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLS product guide (10279). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. Alternative model numbers with suffix* as indicated, intended for French market. 7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed Incorporating the following ancillary equipment: VIC-010 VESDAnet network card VIC-020 Multifunction control card VIC-030 Multifunction control card VRT-V00 Remote VLF display (with 7 relays) VRT-W00 Remote VLF display (no relays) VRT-500 Remote relay unit (with 7 relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide (07208). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. xx denotes alternative language version where xx (range 00 to 99) designates the language of the product labels. 7. Alternative model number with suffix* as indicated, intended for French 2. VESDA VLS High sensitivity aspirating smoke detector VESDA VLF-250-xx (VLF250-01NF*) high sensitivity aspirating smoke detector 374 305d/05 305d/06 20 Oct 2014 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products LPCB Ref. No. market. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Incorporating the following ancillary equipment: VIC-010 VESDAnet network card VIC-020 Multifunction control card VIC-030 Multifunction control card VRT-V00 Remote VLF display (with 7 relays) VRT-W00 Remote VLF display (no relays) VRT-500 Remote relay unit (with 7 relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide (07209). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. xx denotes alternative language version where xx (range 00 to 99) designates the language of the product labels. 7. Alternative model number with suffix* as indicated, intended for French market. 8. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Approved configurations: - VLC-500 (VLF-50000-NF*) VLC Relays only (RO) version - VLC-505 (VLF-50500-NF*) VLC VESDAnet (VN) version - VLC-400 (VLF-400-NF*) VLC Apollo (AP) version - VLC-700 (801519.F0*) VLC Esser (EB) version - VLC-800 (VLF-800-NF*) VLC Tyco (MX) version Approved remote units with the VLC-505 VESDAnet (VN) version: - VRT-J00 Remote VLC display (with 7 relays) - VRT-K00 Remote VLC display (no relays) - VRT-500 Remote relay unit (with 7 relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLC product guides (10280 [VLC-500 & VLC-505], 03494 [VLC-400], 09411 [VLC-700], 09515 [VLC-800]). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. Alternative model numbers with suffix* as indicated, intended for French market. 7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Approved Configurations: VLP-012 (VLP-01200-NF*) VLP detector with Display & Programmer VLP-002 (VLP-00200-NF*) VLP detector with Display VLP-400 (VLP-00000-NF*) VLP detector with Fire/OK LEDs only VLP-401 (VLP-00100-NF*) VLP detector with Programmer & Fire/OK LEDs VLP-100 VLP detector with OEM cover Approved remote units: VRT-100 Remote Programmer VRT-200 Remote VLP Display unit (with 7 relays) VRT-300 VESDAnet socket VRT-500 Remote Relay unit (with 7 relays) 8. VESDA VLF-500-xx (VLF500-01NF*) high sensitivity aspirating smoke detector VESDA VLC High sensitivity aspirating smoke detector VESDA VLP High sensitivity aspirating smoke detector 20 Oct 2014 305d/07 305d/08 305d/09 375 PART 1: SECTION 4.1 COMMERCIAL DETECTORS Certificated Products VESDA VLS High sensitivity aspirating smoke detector XCC-010 (XCC-01000-NF) XCC-010 (XCC-01000-NF) 376 LPCB Ref. No. VRT-600 Remote VLP Display unit (without relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLP product guide (10278). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. Alternative model numbers with suffix* as indicated, intended for French market. 7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Approved Configurations: VLS-600 (VLS-20000-NF*) VLS with 7 relays and Fire/OK LEDs VLS-204 (VLS-20400-NF*) VLS with 7 Relays and Display Module VLS-214 (VLS-21400-NF*) VLS with 7 Relays, Display and Program Module VLS-700 (VLS-30000-NF*) VLS with 12 relays and Fire/OK LEDs VLS-304 (VLS-30400-NF*) VLS with 12 Relays and Display Module VLS-314 (VLS-31400-NF*) VLS with 12 Relays, Display and Program Module VLS-100 VLS with 7 Relays and OEM cover VLS-500 VLS with 12 Relays and OEM cover Approved Remote Units: VRT-400 Remote Scanner Display with 7 relays VRT-700 Remote Scanner Display with no relays VRT-800 Remote Scanner Display with 12 relays VRT-900 Remote Scanner Relays -12 relays VRT-E00 Remote Scanner Relays - 7 relays Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLS product guide (10279). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. Alternative model numbers with suffix* as indicated, intended for French market. 7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed Xtralis Class C aspirating smoke detector Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming with the requirements of EN 54-4. 2. System design, installation and commissioning shall be performed in accordance with the Xtralis Class C XCC-010 product guide (Document 14159). 3. The device is approved for sensitivity Class C. 4. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 5. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. 6. XCC-01000-NF alternative model number intended for French market. Xtralis Class C aspirating smoke detector Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming with the requirements of EN 54-4. 2. System design, installation and commissioning shall be performed in accordance with the Xtralis Class C XCC-010 product guide (Doc