Last updated: 20 Oct 2014

Transcription

Last updated: 20 Oct 2014
Last updated: 20 Oct 2014
VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES
Foreword by the United Arab Emirates (UAE) Acting Commander in Chief, Major
General Rashid Thani Al Matrooshi
As the dynamic environment in our Region progresses, we the UAE Civil Defence Authority, has set forth a
number of strategic goals for the delivery of public safety. Our strategic goals observe both the national and
Ministry of Interior’s strategic plan by;
“Providing an effective firefighting and emergency response system delivered by qualified and well trained
people using the latest technologies to ensure lives and properties are safeguarded”
As a result, the UAE can be ‘benchmarked’ with other Countries that are witnessing a decline in fires and
incidents when compared to the density of population. As an example, the number of fire incidents has been
reduced by 39% in 2011 compared to 2010, with a marked reduction in small and medium fire incidents,
together with a high percentage achievement of a 9 minute response time for first attendance at incidents.
“Providing excellent performance and support during disasters and crises”
Confirmation of performance and support are achieved during disasters and crisis situations. Civil Defence
Departments conduct a range of joint fire safety and evacuation drills in association with other safety agencies
for both the public and private sectors. Evacuation drills carried out in Dubai during 2011 was estimated at
356 drills, which targeted 178,530 persons. Customer satisfaction percentage achieved was 97.2%. The
number of drills carried out has increased by 142.4% compared to the target number set out in our annual
plan.
“Spreading a fire safety and awareness culture across the community “
In this regard, a National Safety campaign was launched targeting ‘domestic safety’ with an achieved target of
50% of homes in UAE being visited during a six month period. This was aimed at preventive awareness and
removing violations which threaten public safety. During the campaign, 206,490 houses (61.4% of the total
dwellings) were visited, again with a marked customer satisfaction percentage of 92%.
Similarly a National Safety campaign was also executed at industrial areas, with teams visiting industrial
facilities at different industrial areas across the country. 31,647 facilities were inspected. The teams also
managed to correct violation situations in 13,400 facilities and 53,426 people were trained in the basic skills of
firefighting and awareness.
“Equipping operations with the best and appropriate equipment and technologies”
The latest state of the art technologies have been introduced for various services such as, ‘e-engineering’ for
online drawing approval and the ’24 x 7 smart system’ for building electronic monitoring and protection.
Currently 61.7% of buildings are connected to the system and 95.7% surveyed for connection.
In addition, the ‘UAE Fire and Life Safety Code of Practice’ with our Standard Operating Procedures (SOPs) is
considered a first in the region. This will contribute to reduced costs and effort. Ultimately this will result in a
decrease in accidents and improve command and control mechanisms.
“Achieving Strategic Partnership with Public/Private and Voluntary Organizations”
By ensuring, through careful selection, that products, systems and installers are approved with a listing by
Civil Defence, following rigorous third party certification. This ensures that locally we receive the best
performance of fire safety products, systems and technologies.
ii
20 Oct 2014
VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES
LPCB is widely recognised as an independent reference for all fire and security safety experts. Their testing
laboratories and approvals services together with their leading team of highly qualified expert scientists and
engineers, guides us all impeccably towards a qualified framework.
Major General Rashid Thani Al Matrooshi
Introduction
Welcome to the 2014 Edition of the “LPCB Red Book”, the list of approved products and services from LPCB.
LPCB is the fire and security approval brand of BRE Global Ltd. which is part of the BRE Group operating
under the BRE Trust. It is an independent third party approvals body offering certification of fire and security
products and services to an international market. The LPCB mark and listings signify that products and
services have been approved by LPCB. The Red Book is an essential reference for specifiers, regulators,
designers and end users of these products and services - if it is listed here, you know it has been checked out
by people you can trust
BRE Global also offers independent approval of construction products, management systems and in the area
of sustainability though its BRE Global Certification and BREEAM brands. Where these have relevance to fire
safety and security these are also listed in the Red Book (The details of these schemes are given in the
relevant introductory sections.)
BRE Global Ltd is also a Notified Body for the purpose of CE marking and European Technical Assessment in
connection with the European Construction Product Regulation (CPR) and other European Directives; the
Pressure Equipment Directive (PED), Marine Equipment Directive (MED) and Transportable Pressure
Equipment Directive (TPED).
BRE Global - protecting people, property and the planet.
The Red Book is divided into sections which list related groups of products and services such as suppression,
security and so on. Each section also summarises the technical basis for the approval of each product or
service. The Red Book should always be used in conjunction with rules, regulations and design specifications
required by the relevant Authority having jurisdiction.
The 2014 edition of the Red Book comprises:
20 Oct 2014
iii
VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES
Volume 1: (This Volume)
 Fire detection and alarm products, systems, and cables
 Manual fire extinguishing equipment
 Automatic sprinkler, water spray and deluge systems
 Fixed fire fighting products and systems
 Related installers
Volume 2:
 Passive fire protection products
 Security protection products
 Fire doors and shutters
 Smoke and fire ventilation systems
 Related installers
 Management Systems
 Construction products
Listings are given in the name of the manufacturer or service provider, in alphabetical order. They can be
downloaded free of charge from our website at www.redbooklive.com and also via an App that is available
free from Apple iStore (for iPhone and iPad), from Google Play, (for Android phones and tablets) and
Windows Store (for Windows 8 phones).
Red Book updates
Product and services approval details are amended regularly. To ensure that you are using the most up to
date information please refer to www.redbooklive.com or download the App.
What is Third Party Approval?
A frequent concern of stakeholders is in knowing whether a product will perform in accordance with the stated
specifications. These concerns can involve such product attributes as safety, health or environmental impacts,
durability, compatibility, suitability for intended purposes or for stated conditions, and other similar
considerations. These issues can all be addressed through product approvals.
Third party approval (or certification) is a conformity assessment process, carried out by a body that is
independent of both supplier and customer organisations. It provides confirmation that products and services
have met and will continue to meet the requirements of specified standards and other normative documents.
LPCB third party product approval schemes are quality assurance schemes and comprise initial type testing
and technical evaluation, assessment and surveillance of the manufacturer’s quality system and production
procedures, regular audit testing, labelling and listing.
Similarly, LPCB schemes for suppliers of services (installers) are also quality assurance schemes comprising
a technical assessment of an installer’s capability, assessment and surveillance of the installer’s quality
system and production procedures, regular inspection of completed installations and listing.
Benefits of Third Party Approval
For specifiers, regulators, insurers, manufacturers and installers, the benefits of an LPCB approval are:
For specifiers and regulators:
iv
20 Oct 2014
VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES



Risk reduction - specifying LPCB approved products and services demonstrates due-diligence and
best endeavour and mitigates against possible accusations of negligence.
Avoidance of costly mistakes - you can trust LPCB approved products and services to conform each
and every time.
Time - using Red Book Live to search for and assess products and services can save you time.
For manufacturers and installers:
 Increased global sales - LPCB approval is recognised and specified widely throughout the world. In
some territories LPCB approval is a mandatory requirement.
 Added value of the product or service - LPCB approved products and services are recognised as
providing added value given their ability to conform each and every time.
 Reduced liability - LPCB approved products and services demonstrate due-diligence which can
reduce liability for both you and your customers.
What does LPCB Approval offer?
LPCB offers approvals to existing British, European, International and LPCB’s own Loss Prevention
Standards (LPSs). LPCB’s LPS approval schemes for both products and services are essentially level 5
schemes, as described in ISO/IEC Guide 67, with the added requirement to have a quality system certificated
to ISO 9001.
The technical requirements of LPCB schemes are given in Loss Prevention Standards (LPSs). These
documents are drafted by LPCB technical experts in conjunction with appropriate external experts. They are
then peer reviewed by representatives from trade bodies, regulators, insurers, specifiers, manufacturers and
other suppliers. Finally these documents are approved for use by the BRE Global Governing Body; the Body
that oversees all of the certification activities of BRE Global, including LPCB.
Product schemes comprise:
 Initial type testing and evaluation of product, sampled by LPCB.
 Approval and surveillance of the manufacturer’s (or supplier’s) quality management system to ISO
9001 (if you have products in for testing at LPCB, it generally costs little or no more to achieve ISO
9001 certification).
 Assessment and surveillance of the manufacturer’s (or supplier’s) factory production control system
(FPC).
 Periodic audit testing of the product from either the factory or marketplace.
 Labelling or marking as appropriate.
 Listing of the approved product (service) in the Red Book
Installer schemes comprise:
 Technical assessment of the installation contractor’s capability.
 Approval and surveillance of the contractor’s quality management system to ISO 9001 or assessment
against the requirements of the relevant Loss Prevention Standard where ISO 9001 is not
appropriate. (If you have applied for LPCB assessment of your services, it generally costs little or no
more to achieve ISO 9001 certification).
 Regular surveillance inspections of on-going installations.
 The issue of Certificates of Conformity to demonstrate compliance for each installation.
 Listing of the approved installer in the Red Book.
The LPCB Mark - the Mark you can trust
After approval of a product or service the manufacturer or service provider is allowed to place the LPCB
certification mark, as shown below , on the product, packaging and literature etc. In September 2011 this
image was updated.
20 Oct 2014
v
VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES
To this
from
(Discontinued for new approvals
from 1 October 2011)
A transition period of up to three years has been allowed for the change, so although we expect many of our
clients’ product(s) will already be carrying the new version of the mark, the ‘old’ mark remains valid and you
can still rely on the products carrying the old mark where their certificate was issued before 1 October 2011.
Together with the mark you should always determine the product/service certificate number and check if a
listing still valid by going to www.redbooklive.com.
Where LPCB holds accreditation through the United Kingdom Accreditation Service (UKAS), the approved
company is allowed to include the UKAS symbol (the Crown and Tick) alongside the LPCB mark for certain
applications e.g. promotional literature or material and stationery, as shown below.
(Full details of LPCB accreditation can be found on the UKAS website at www.ukas.com)
Where for reasons of space or cost the use of the above full mark is not practical, then the following simplified
mark may be applied directly to the product (for some schemes only).
The LPCB scheme rules define how and where the marks can be used.
The LPCB horseshoe is the mark you can trust and it is recognised in over 60 countries around the world by
regulators, specifiers, designers and end users.
For Fire and Security Products and Services Trust the LPCB Mark
Other Listings from BRE Global
vi
20 Oct 2014
VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES
20 Oct 2014
vii
CONTENTS
1 Fire detection and alarm products, systems & cables
1
SECTION 2 Fire detection and alarm systems
3
SECTION 3 Control and indicating equipment
7
SECTION 3 LPS 1014 certified fire detection and alarm system firms
208
SECTION 4.1 Commercial detectors
219
SECTION 4.2 Domestic alarms - smoke, heat and carbon monoxide
381
SECTION 5 Manual call points
393
SECTION 6 Line units
424
SECTION 7 Alarm warning devices
447
SECTION 8 Fire resistant cables
538
SECTION 9 Alarm receiving centres
616
SECTION 10 Alarm transmission and fault monitoring equipment and signalling systems
618
SECTION 10.1 Alarm transmission and fault warning routing equipment
620
SECTION 10.2 Supervised premises transceivers (fire) - LPS 1277 Issue 2.2
621
SECTION 10.3 Supervised premises transceivers (fire) - LPS 1277 Issue 3
622
viii
20 Oct 2014
INDEX
2
2M KABLO SAN. ve TIC. A.S.
540
3
3E - Electrical Energy Efficiency FZE
541
A
Aarhus Fire Protection Limited
208
ADI (ADEMCO)
8
ADI International
220
ADT Fire and Security
208, 209
Advanced Electronics Limited
9, 221, 393, 424,
448
Advantronic Systems S.L.
223, 394, 425, 449
AEI Cables Limited
541
AGNI Devices PVT Ltd
225
Agni Suraksha Electronics Services
382
Aguilera Electronica S.L
226
Ajax Chubb Varel B.V.
11
Alarm Supply Pte Ltd
227
Alberta Fire & Security Equipment Limited
209
Alpha Fire Services W.L.L.
547
AMPAC Europe Limited
12
AMPAC Technologies PTY Ltd 17, 227, 394, 425,
450
Apollo Fire Detectors Limited 229, 395, 426, 451
Application Solutions (Safety and Security) Ltd,
East Sussex, United Kingdom
20
Argus Fire Protection Company Limited
209
Argus Security S.r.l.
239, 396, 427, 455
Argus-Spectrum
242, 396, 427, 457
ATEIS Middle East FZCO
245, 397, 427, 459
ATOM KABLO SANAYI VE TICARET A.S.
547
Autronica Fire & Security AS
248, 428, 460
B
Bahra Cables Company
549
Bailey Maintenance
210
Banham Alarms (Prop
Banham Patent Locks Limited)
616
Bardic by Honeywell (Novar Systems Ltd) 21, 248,
461
BBC Fire Protection Limited
210
Beijing Leader Huaxin Electronics Co. Ltd 22, 249
Beijing VSAIL Fire Protection Equipment Co Ltd
249, 461
Bentel Security s.r.l.
397
BERICA CAVI S.p.A.
550
Biamp Systems Corporation
22
Bosch Security Systems BV
24
Bristol Fire Ltd
250, 397, 462
Building Protection Systems (NI) Limited
25
C
CAMS Fire & Security PLC
210
Carillion (Novar Systems Ltd)
28
Cavicel SpA
550
Ceasefire Industries Ltd
251, 398, 462
Channel Safety Systems Ltd
29
Chiron Security Communications Limited
622
Chubb Fire & Security Limited
210
Chubb Fire & Security Ltd
428
Chubb Fire and Security Limited
623
20 Oct 2014
Chubb Fire Ltd
251
Clymac Limited
210
Computionics Limited (Trading as C-Tec)
30
Consilium Marine and Safety AB
252
Context Plus Ltd
35, 252, 398, 428, 553
Control Equipment Limited
4, 37, 253, 398, 429,
463
Cooper Fulleon Limited
399, 465
Cooper Industries Inc
45, 399
Cooper Lighting and Safety Ltd
46, 400, 466
Cooper MEDC Ltd
468
Cooper Safety
254
Cooper Sécurité SAS
257
Cranford Controls Limited
468
CSL DualCom Limited
621
CTM Fire and Security Limited
210
D
Daemon Fire and Security Limited
211
Dätwyler Cabling Solutions AG
554
Defensor Group Limited
211
Detector Electronics Corporation
49, 259, 429
Digital Security Controls, a Division of Tyco Safety
Products Canada Ltd
382
Direction Fire Limited
211
Doncaster Cables
555
Draka (Malaysia) Sdn. Bhd.
556
Draka UK Limited
557
Dubai Cable Company (Private) Limited, Trading
as Ducab
562, 563, 566
E
EA-RS Group Limited
211
EDS Elektronik Destek San. ve Tic. Ltd. Şti.
259
Eland Cables
566
Elmdene International Ltd
469
EMCOR Facilities Services Limited, EMCOR
Specialist Services
211
EMCS - East Midlands Central Station Limited 616
Emergi-Lite Safety Systems (Thomas & Betts Ltd)
259, 400
Emico Limited
211
Emirates Fire Fighting Equipment Factory L.L.C.
(FIREX)
261, 400, 470, 567
Emirates Fire Protections Equip. Factory. TR.
Section
51, 261, 401, 430, 470
ESYLUX GmbH
382
Eurofyre Limited
262
Eurotech Fire Systems Limited 53, 263, 401, 430,
471
Everday Technology Co. Limited
265, 383, 401
Eyston Company Ltd
384
F
Fike Safety Technology Ltd 55, 267, 402, 431, 472
Finder Elektronik A.S.
270, 402, 431, 473
Fire Fighting Enterprises Ltd
272
Fireblitz Extinguisher Ltd
384
Fireguard Safety Equipment Co Ltd 272, 403, 474,
568
Firelite by Honeywell (Pittway Systems
Technology Group (Europe) Ltd)
58, 273
ix
INDEX
Fireonica Co. Ltd
274, 403
Firesafe
59, 384, 568
Firetecnics Systems Limited
212
Fsc Export Ltd
274, 403, 474
G
GBE Fire & Security (a division of GB Electronics
Limited)
212
Gent By Honeywell (Novar Systems Ltd) 60, 275,
404, 431, 475
GEZE GmbH
282, 432
Gira Giersiepen Gmbh & Co. KG
385
Global Fire Equipment S.A.
404, 478
Global Fire Systems Limited trading as Global Fire
& Security Systems
212
Grainger Fire Systems
212
Grupo General Cable Sistemas, S.A.
569
Grupo General Cable Sistemas, S.L.
570
Gulf Security Technology Co., Ltd. 65, 282, 405,
432, 478
Gutkes GmbH
385
H
Haes Systems Limited
69, 284, 405, 432, 479
Hall & Kay Fire Engineering (Ashford)
212
HDR
285, 405, 433, 480
Hochiki America Corporation
286
Hochiki Corporation
287
Hochiki Europe (UK) Limited
288, 406, 433, 483
Honeywell Automation (I) Pvt. Ltd
294
Honeywell Control Systems Limited
296, 435
Honeywell Control Systems Ltd 74, 298, 406, 435
Honeywell International Inc
79
Honeywell Life Safety Systems (Novar Systems
Ltd)
299
Horing LIH Industrial Co Ltd
300, 407, 493
Hosiden Besson Limited
494
Huzhou Jiusheng Electric Co Ltd
571
I
I.C. Service & Maintenance Limited
213
Iceberg Building Services Limited
213
INIM Electronics s.r.l.
302, 407, 435
Intelligent Safety & Security Technology Ltd. 303,
407, 494
J
Jalo Helsinki Oy / Jalo Ltd
386
Jaylow Supplies Ltd
572
John Lewis Partnership
386
K
KAC Alarm Company Limited
408, 495
Kentec Electronics Limited
82
Keystone Electric Wire & Cable Company Ltd 573
Kidde Finland Oy
386
Kidde Products Ltd
304, 412, 436
Kidde Products Ltd, trading as AirSense
Technology
305
Kidde Safety Europe Ltd
387
Kingfell Engineering Limited
213
Kingfisher Security (UK) Limited trading as
Kingfisher Fire & Security
213
KME Italy SpA
574
x
L
Labor Strauss Sicherungsanlagenbau GmbH 306,
412, 507
LEONI Studer AG
576
Lichfield Fire & Safety Equipment Co. Ltd
(LIFECO)
307
Lloret Fire and Security Limited
213
M
M. J. Quinn Integrated Services Limited 213, 214
Mavili Elektronik Ticaret Ve Sanayi A.S. 83, 308
MECE Fire & Security Limited
214
Mercury Engineering
214
MGC Systems Corp.
413
MICC (Shanghai) Electric Co Ltd
581
Mineral Insulated Cable Co Ltd
582
MITIE Technical Facilities Management Limited
214
MITIE Technical Facilities Management Limited
(MITIE Fire and Security Systems)
214
Morley-IAS Fire Systems By Honeywell
87, 308
Morley-IAS Fire Systems by Honeywell (Pittway
Systems Technology Group (Europe) Ltd) 88,
310, 413, 436, 508
Multron Systems Pte Ltd
91, 313, 414, 436, 513
N
NAJD ELECTRICALS & SAFETY EQUIPMENT
TRADING
583
National Monitoring (Prop. AVR Group Limited)617
Nexans Schweiz AG
584
Nexans Sweden AB
584
Nexans Turkiye Endustri ve Ticaret A.S.
585
NG Bailey Limited - Rail Division
214
NINGBO LONGMAX ELECTRONIC CO., LTD 387
Ningbo Siterwell Electronics Co., Ltd.
389
Nitin Ventures FZE
93, 314, 414, 437, 514, 586
Nittan Europe Limited
315
Norden Communication UK Ltd
586
Notifier by Honeywell (Pittway Systems
Technology Group (Europe) Ltd)6, 94, 316, 414,
437, 514
Notifier Fire Systems India
319
O
Olympia Electronics S.A.
99, 320
OLYMPIC CABLE COMPANY SDN. BHD.
588
Oman Cables Industry (SAOG)
588
Orient Corporation Pte. Ltd.
100, 321, 516
P
Panasonic Corporation
321, 437
PEL Services Limited
215
Pelco Finland Oy
101, 322, 415, 438, 516
Pentair Thermal Management Canada Limited 589
Pentair Thermal Management UK Limited
591
Philton Fire & Security Limited
324
Photain Controls
103
Pittway Tecnologica Srl.
324, 438
Plana Fabrega
329
Protec Fire Detection plc 104, 215, 330, 415, 439,
517
Prysmian Cables & Systems Limited
592, 599
20 Oct 2014
INDEX
PX Manufacturing & Distribution Company Limited
601
R
RAMCRO S.p.A. (including RAMCRO S.p.A.
Trading as B3 Cables Solution)
601
Ravel Electronics Ltd
334, 416, 518
S
Sabre Fire & Security Ltd
389
Safety Hi-Tech Srl
335, 439
Safety Technology International (Europe) Limited
416
Safex Fire Services Limited
335
Sareme UAB
336, 416
SAXA, Inc
518
Schlumberger Oilfield UK PLC, Sensor Highway
Limited (Schlumberger, Southampton)
337
Schneider Electric Buildings Sweden AB
108
Schneider Electronic Buildings AS
108
Schrack Seconet AG
417
Scotshield Limited
215
secudo GmbH
390
Securiton AG
417
Sensetech Systems Limited
215
Shakun Polymers Limited
603
Shenzhen Fanhai Sanjiang Electronics CO., Ltd
390
Shenzhen Heiman Technology Co Ltd
337
SHIELD FIRE, SAFETY AND SECURITY LIMITED
439, 604
SHIELD FIRE, SAFETY AND SECURITY LTD109,
338, 417, 440, 519, 604
Siemens plc, Building Technologies, Fire Safety
Division
216
Siemens Switzerland Limited, Building
Technologies Division 111, 339, 417, 440, 519
SMS (Novar Systems Ltd) 121, 346, 419, 442, 521
Southern Monitoring Services Limited
617
Sprue Safety Products Ltd
390
Static Systems Group Plc
216
Sterling Safety Systems
349, 419, 442, 521
Synaps Technology Srl
420
System Sensor
352
System Sensor Europe
352, 523
System Sensor Europe, Life Safety Distribution
AG
523
System Sensor, Honeywell International (I) PVT.
Limited
352
T
T Clarke Public Limited Company
216
20 Oct 2014
T V F (UK) Limited
216
Tai Sin Electric Limited
605
Tanda Technologies (Singapore) Pte Ltd
356
Teledata S.r.l.
356, 420, 528
TELE-FONIKA Kable Sp. z o.o., S.K.A.
606
Teletek Electronics JSC
358
Texecom Ltd
529
Thameside Fire Protection Co. Limited
216
Thorn Security Limited, Trading as Tyco Safety
Product
123
Thorn Security Limited, trading as Tyco Safety
Products
358, 420, 442, 533
Tratos Cavi SpA
609
Trinity Fire and Security Systems Ltd (Abingdon)
216
Trinity Fire and Security Systems Ltd (Exeter) 217
Trinity Fire and Security Systems Ltd (Honiley) 217
Turk Prysmian Kablo ve Sistemleri A.S.
610
Tyco Fire and Integrated Solutions (the trading
company for Tyco Fire and Integrated Solutions
(UK) Limited and Tyco Fire and Integrated
Solutions (Ireland) Limited)
217
U
Union Cable Company Ltd
611
UniPOS Ltd
364
UTC CCS Manufacturing Polska, Sp. Zo.o
137
UTC Fire & Security (Africa) trading as Ziton 171
UTC Fire & Security (Pty) LTD Trading as Ziton
171
UTC Fire & Security BV
172, 365, 421, 443
UTC Fire & Security BV.
623
UTC Fire & Security Inc. Trading as Edwards
Systems Technology 200, 367, 422, 444, 535
V
Ventcroft Limited
612
Vimpex Limited
445, 536
Vipond Fire Protection Limited
218
Visonic
392
VRC Terofire Products
369
W
Wagner Group GmbH
369
WebWayOne Ltd
624
Wrexham Mineral Cables
614
X
Xtralis Pty Limited
204, 372
Z
Zarja Elektronika d.o.o
204
Zeta Alarm Systems by GLT Exports Limited 205,
378, 392, 423, 446, 537
xi
Part
1
FIRE DETECTION AND
ALARM PRODUCTS,
SYSTEMS & CABLES
PART 1: FIRE DETECTION AND ALARM PRODUCTS, SYSTEMS &
CABLES
INTRODUCTION
A working fire detection and alarm system will increase the level of safety in a building by automatically
warning occupants of fire before they would otherwise detect it.
To ensure the system works, the system must be designed correctly, products must be correctly selected and
the systems must be correctly installed and maintained. It is recommended that all systems are designed,
installed, commissioned and maintained by contractors who are approved by LPCB to LPS 1014 and that they
are connected to Alarm Receiving Centres approved to LPS 1020.
Listings in this section include:
Products








Control and indicating equipment including voice alarm and power supplies
Wireless, flame, beam, aspirating, smoke, heat and multi-sensor detectors
Manual call points
Line units including input and output devices
Alarm warning devices including visual alarms, loudspeakers and sounders
Cables
Alarm transmission equipment
Signalling systems
Products are approved in accordance with a range of standards. The details of these standards are given at
the front of each section relevant to the product. Some of the above products may be hard wired or wireless
(Radio link). Wireless products should also be approved to EN 54-25.
Systems
Fire detection and alarm systems are approved for system compatibility in accordance with:
 LPS 1054: Requirements and testing procedures for the approval and listing of component
compatibility for fire detection and alarm systems.
 EN 54 - Part 13: Compatibility assessment for system components.
Design, installation, commissioning and maintenance contractors
Contractors are approved in accordance with:
 LPS 1014: Requirements for certificated fire detection and alarm system firms.
 LPS 1020: Alarm Receiving Centres
2
20 Oct 2014
PART 1: SECTION 2
FIRE DETECTION AND ALARM SYSTEMS
A fire detection and fire alarm system is typically made up of a number of inter-linked components including
detectors, manual call points, and alarm sounders connected to control and indicating equipment by means of
one or more transmission paths. All system components, including the control and indicating equipment are
also connected to a power supply directly or indirectly.
A fire detection and alarm system may be linked to other systems such as fire protection, or building
management systems. These other systems are not considered as part of the fire detection and alarm
systems.
The fire detection and alarm systems may be networked together.
Each of the components that constitute the fire detection and alarm system may be individually tested and
approved against their appropriate standard to demonstrate their own performance and reliability but in order
to ensure their compatibility and performance together within the system, certain system tests and
requirements must be fulfilled.
The system standard specifies the requirements for compatibility and connectability assessment of system
components that either comply with the requirements of EN 54 and/or with a manufacturer’s specification. The
standard also includes requirements for the integrity of the fire detection and fire alarm system when
connected to other systems.
This section lists approved fire detection and alarm systems suitable for use in buildings for the protection of
people and property. The system requirements ensure the compatibility of the different components of the
system work reliably together. Each component of the fire detection and alarm systems listed in this section
are approved to the applicable product standard and are listed in Sections 3, 4.1, 5, 6, and 7. The approval
process for the system is outlined in scheme document SD040.
Systems listed in this section have been approved to LPS 1054: 2001 Requirements for the evaluation of
component compatibility for fire alarm systems
This standard was designed for the UK market and applies to systems incorporating control and indicating
equipment and power supply equipment complying with EN 54-2 Fire detection and fire alarm systems Control and indicating equipment and EN 54-4 Fire detection and fire alarm systems - Power supply
equipment respectively.
Networked systems are evaluated by ensuring that each control panel connected to the network can operate
as a stand alone unit, in the event of failure of the network connections, and that failure of a control panel will
not affect other control panels on the network.
LPCB is now accepting products for approval to EN 54-13: 2005 Compatibility assessment for system
components which is applicable to the EU market and to LPS 1653: 2011 Requirement for Network fire
detection and alarm systems.
Note: Since LPCB uses national and international standards for the listing of products, in some instances, the
requirements of these standards may conflict with the recommendations of local codes of practice. We
recommend that specifiers seek advice from the relevant local authorities and amend their specifications
accordingly.
20 Oct 2014
3
PART 1: SECTION 2
FIRE DETECTION AND ALARM SYSTEMS
Control Equipment Limited
Hillcrest Business Park, Dudley, West Midlands DY2 9AP, United Kingdom
Tel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972
E-mail: [email protected] • Website: www.controlequipment.com
Certificate No: 018b to LPS 1054-1
Certificate No: 018d to LPS 1054-1
Certificate No: 018u to EN 54-13: 2005
Fire Detection and Alarm Systems
Certificated Products
Precept fire alarm system
Comprising the following products:
LPCB Ref.
No.
018b/S1
Control Equipment Limited
Precept 2, 4, 8, 16 and 32 zone control and indicating equipment.
Apollo Fire Detectors Limited
55000-100 grade 1 rate of rise heat detector (45681-200 base)
55000-200 ionization smoke detector (45681-200 base)
55000-300 photoelectic smoke detector (45681-200 base)
53531-221 grade 1 rate of rise heat detector (45681-007 base) continued
53541-151 ionization smoke detector (45681-007 base)
53541-200 photoelectric smoke detector (45681-007 base)
55000-101 grade 2 rate of rise heat detector (45681-200 base)
55000-102 grade 3 rate of rise heat detector (45681-200 base)
55000-103 range 1 rate of rise heat detector (45681-200 base)
55000-104 range 2 rate of rise heat detector (45681-200 base)
55000-210 integrating ionization smoke detector (45681-200 base)
Hochiki Corporation
DFE-60 grade 2 fixed temperature heat detector (YBF-RL/4H5 base)
DFE-90 range 1 fixed temperature heat detector (YBF-RL/4H5 base)
DCC-1EL grade 1 rate of rise heat detector (YBF-RL/4H5 base)
DCC-2EL grade 2 rate of rise heat detector (YBF-RL/4H5 base)
DCC-R1EL range 1 rate of rise heat detector (YBF-RL/4H5 base)
Hochiki Europe
SLK-E photoelectric smoke detector (YBF-RL/4H5 base)
SIH-E ionization smoke detector (YBF-RL/4H5 base)
KAC Alarm Company Limited
KR72 manual call point.
Photain Controls Limited
ISD-P91 ionization smoke detector
PRR-P91 grade 1 rate of rise heat detector
PHD-P90 range 1 fixed temperature heat detector
Signature Industries - Clifford and Snell Alarms.
MCP/R/F manual call point
MCP/R/S manual call point
System Sensor, St. Charles, Illinois, USA.
1151E ionization smoke detector (B401 base)
2151E photoelectric smoke detector (B401 base)
Discovery fire alarm
system
Comprising the following products:
018d/01
Control Equipment Limited
Discovery analogue addressable control and indicating equipment
Apollo Fire Detectors Limited
55000-400 grade 2 analogue temperature monitor
55000-420 grade 2 analogue temperature monitor
58000-400 Discovery temperature monitor
55000-600 analogue photoelectric smoke monitor
55000-620 analogue photoelectric smoke monitor
58000-600 Discovery optical smoke monitor
55000-500 analogue ionisation smoke monitor
55000-520 analogue ionisation smoke monitor
58000-500 Discovery ionisation smoke monitor
58000-700 Discovery multisensor monitor
55000-900 surface and flush mounted manual call point
55000-910 flush mounted manual call point
55000-950 waterproof addressable manual call point
58000-900 flush and surface mounted manual call point
4
20 Oct 2014
PART 1: SECTION 2
FIRE DETECTION AND ALARM SYSTEMS
Certificated Products
LPCB Ref.
No.
58000-910 flush mounted manual call point
58000-920 surface mounted manual call point
55000-700 XP95 short circuit isolator
45681-321 XP95 negative isolating base
45681-210 XP95 addressable mounting base
FireClass Fire Detection
System
Comprising the following products:
018u/01
Commercial Detectors
FC460P Digital addressable photoelectric smoke detector (4B, 4B-I and 5B bases)
FC460PH Digital addressable photoelectric smoke and Class P heat detector (4B, 4B-I
and 5B bases)
FC460PC Digital addressable photoelectric smoke, Class P heat and carbon monoxide
detector (4B, 4B-I and 5B bases)
FC460H Digital addressable Class P heat detector (4B, 4B-I and 5B bases)
Manual Call Points
FC420CP
Addressable Type A indoor manual call point
FC421CP Addressable Type A outdoor manual call point
Line Units
4B-I
Short circuit isolator base
FC410QIO
Quad input/output module with short circuit isolator
FC410QRM
Quad relay module with short circuit isolator
FC410QMO
Quad monitored output module with short circuit isolator
Alarm Warning Devices
FC410LPSYR
Addressable loop powered Type A sounder (red) with short circuit
isolator
FC410LPSYW
Addressable loop powered Type A sounder (white) with short circuit
isolator
FC410LPSY
Addressable loop powered Type B sounder (red) with short circuit
isolator
FC410LPAVR
Addressable loop powered Type A sounder beacon (red) with short
circuit isolator
FC410LPAVW
Addressable loop powered Type A sounder beacon (white) with
short circuit isolator
FC410LPAV
Addressable loop powered Type B sounder beacon (red) with short
circuit isolator
FC430LPASB
Loop powered sounder beacon base with short circuit isolator
FC430LPSB
Loop powered sounder base with short circuit isolator
FC430SB Analogue addressable type A sounder base
Control and Indicating Equipment
FC32-1 FireClass (557.200.701) Analogue Addressable Control and Indicating
Equipment, 1 loop, 32 Zone
FC64-2 FireClass (557.200.702) Analogue Addressable Control and Indicating
Equipment, 2 loop, 64 Zone
FC64-4 FireClass (557.200.703) Analogue Addressable Control and Indicating
Equipment, 4 loop, 64 Zone
FC240-2 FireClass (557.200.704) Analogue Addressable Control and Indicating
Equipment, 2 loop, 240 Zone
FC-240-4 FireClass (557.200.705) Analogue Addressable Control and Indicating
Equipment, 4 loop, 240 Zone
Bases:
4B Universal mounting base
4B-I Isolator base
5B Standard mounting base
General note:
For further information on each individual product including approved sensitivities, heat classification, sounder tones etc, refer to model
reference number(s) in the appropriate section of the Red Book or on www.redbooklive.com
20 Oct 2014
5
PART 1: SECTION 2
FIRE DETECTION AND ALARM SYSTEMS
Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd)
Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom
Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888
E-mail: [email protected] • Website: www.notifierfiresystems.co.uk
Certificate No: 154e to lps 1054: Issue 2.1
Certificated Products
Notifier NFS2-8 Fire Alarm
System
LPCB Ref.
No.
154e/S1
Comprising the following products:
Notifier Fire Systems Ltd
124-345-002 NFS2-8, 2 Zone Conventional Control and Indicating Equipment
124-345-004 NFS2-8, 4 Zone Conventional Control and Indicating Equipment
124-345-008 NFS2-8, 8 Zone Conventional Control and Indicating Equipment
Morley-IAS Fire Systems
ECO 1002 Photoelectric smoke and heat detector
ECO 1003 Photoelectric smoke detector
ECO 1004T High Temperature 78C heat detector class BS
ECO 1005 Heat detector class A1R
ECO 1005T Fixed temperature heat detector class A2S
KAC Alarm Company Ltd
MCP1A-Rxxxxx Indoor/outdoor surface/flush mounting
conventional manual call point
NS4/R Sounder 4 tone wall mounting conventional (red)
NS4/W Sounder 4 tone wall mounting conventional (white)
NS14/R Sounder 14 tones wall mounting conventional (red)
NS14/W Sounder 14 tones wall mounting conventional (white)
6
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Control and Indicating Equipment (CIE) is a component of a fire detection and alarm system through which
other components may be connected to it such as detectors, manual call points, sounders, routing equipment,
voice alarm equipment and fire protection equipment. It is supplied with power from power supply equipment
which may be housed within the CIE enclosure or a separate enclosure.
CIE is used to receive and send out signals that are related to fire. CIE also monitors the system for faults
(short and open circuit or power supply faults) and indicates the status of the fire detection and alarm system.
CIE designed to meet a European standard such as EN 54-2 or international standard such as ISO 7240-2
has certain options with requirements. For example, it may be designed to provide a signal to fire protection
equipment or have dependencies on more than one alarm signal. Some CIEs have other functions which are
not specified in the standard. These additional features are normally assessed such that they do not
jeopardise compliance.
The choice of CIE is dependent on the specific applications as recommended in the application guidelines for
a specific job or building.
Some CIEs have associated repeaters or mimic panels. These are normally used to repeat the indications
given on the main CIE and sometimes they have control functions such as silencing sounders. There are no
published standards that these repeaters or mimics can be tested against.
Voice Alarm Control and Indicating Equipment (VACIE) is a component of the fire alarm system which
receives signals from the CIE or via manual control in order to activate messages via loudspeakers. VACIE
may also include emergency microphone to broadcast live messages. The approval processes for this type of
equipment is outlined in scheme document SD040.
This section lists Control and Indicating Equipment, Voice Alarm Control and Indicating Equipment and power
supply equipment approved for use in fire detection and fire alarm systems in buildings. Repeaters or mimics
that are listed in this section are only approved with their associated CIE and are subjected to the same
environmental tests as the CIE. The approval processes for this type of equipment is outlined in scheme
document SD040.
Products listed in this section have been approved to:
EN 54-2: 1997 Control and Indicating Equipment;
EN 54-2: 1997 + A1: 2006 Control and Indicating Equipment;
EN 54-4: 1997 Power supply equipment;
EN 54-4: 1997 + A1: 2002 and A2: 2006 Power supply equipment;
ISO 7240-2: 2003 Control and Indicating Equipment;
ISO 7240-4: 2003 Power supply equipment;
EN 54-16:2008 Voice Alarm Control and Indicating Equipment.
Audit:
Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing
standards and continued compliance with the applicable product standard.
Notes:
1. EN 54-2: 1997 is a harmonised standard for the Construction Products Directive and CE marking is
required for most of the European market from 1 August 2009. It is therefore recommended that control and
Indicating Equipment are certificated to EN 54-2: 1997 + A1: 2002
2. EN 54-4: 1997 is a harmonised standard for the Construction Products Directive and CE marking is
required for most of the European market from 1 August 2009. It is therefore recommended that power supply
equipment are certificated to EN 54-4: 1997 + A1: 2002 and A2: 2006.
3. Since the LPCB uses national and international standards for the listing of products, in some instances the
requirements of these standards may conflict with the recommendations of local codes of practice. We
recommend that specifiers seek advice from the relevant local authorities and amend their specifications
accordingly.
20 Oct 2014
7
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
4. Where the Control and Indicating Equipment is of modular construction, and the use of certain modules (or
printed circuit boards PCBs) is optional, these are listed with the applicable equipment.
ADI (ADEMCO)
Via della Resistenza, 53/59 20090 Buccinasco, Milano, Italy
Tel: +3902457179229 • Fax: +390245701034
E-mail: [email protected] • Website: www.adiglobal.com
Certificate No: 429c-(cl-1) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Control and indicating equipment
Certificated Products
CXN-1-S
CXN-2-M
Single loop control and indicating equipment
714-001-111
PANEL DXc1-S SINGLE LOOP REGION 1
(UK & Iceland)
714-001-112
PANEL DXc1-S SINGLE LOOP REGION 2
(Iberia, India & ME)
714-001-113
PANEL DXc1-S SINGLE LOOP REGION 3
(Dutch, French, Italian, Slovenian)
Incorporating as modular units:
124-410-001 Base PCB 1 Loop
124-411 Display PCB
010-115 PSU RS-50-24
Two loop control and indicating equipment
714-001-221
PANEL DXc2-M TWO LOOP REGION 1
(UK & Iceland)
714-001-222
PANEL DXc2-M TWO LOOP REGION 2
(Iberia, India & ME)
714-001-223
PANEL DXc2-M TWO LOOP REGION 3
(Dutch, French, Italian, Slovenian)
LPCB Ref.
No.
429c/13
429c/14
Incorporating as modular units:
CXN-4-M
124-410-001
Base PCB 1 Loop
124-411
Display PCB
010-115
PSU RS-50-24
Four loop control and indicating equipment
714-001-241
PANEL DXc4-M FOUR LOOP REGION 1 (UK & Iceland)
714-001-242
PANEL DXc4-M FOUR LOOP REGION 2 (Iberia, India & ME)
714-001-243
PANEL DXc4-M FOUR LOOP REGION 3
(Dutch, French, Italian, Slovenian)
429c/15
Incorporating as modular units:
124-410 Base PCB 2 Loop
124-411 Display PCB
124-417 2 Loop PCB
010-116 PSU RS-100-24
Incorporating as optional modular units:
795-099 KIT DXc NETWORK CARD
795-102 KIT DXc 40 ZONE LED CARD
795-103 KIT DXc 80 ZONE LED CARD WITH COVER
795-111 KIT DXc 2 LOOP EXPANSION CARD (Applicable to the two loop CIE only)
795-117 KIT DXc PERFORMANCE CARD
795-118 KIT DXc KEYSWITCH
795-122 KIT DXc RS232
795-123 KIT DXc RS485
795-124 KIT DXc 80 ZONE LED CARD
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
7.12.3
Dependencies on more than one alarm signal-Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each addressable point
10
Test condition
8
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Notes:
1.
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2.
Scope of approval does not include the operation of the network functionality.
CXN-1-M
Single loop control and indicating equipment
714-001-111
PANEL DXc1-S SINGLE LOOP REGION 1
Iceland)
714-001-112
PANEL DXc1-S SINGLE LOOP REGION 2
(Iberia, India & ME)
714-001-113
PANEL DXc1-S SINGLE LOOP REGION 3
(Dutch, French, Italian, Slovenian)
714-001-114
PANEL DXc1-S SINGLE LOOP REGION 4
(German)
429c/16
(UK &
Incorporating as modular units:
124-410-001
Base PCB 1 Loop
124-411 Display PCB
010-115 PSU RS-50-24
Advanced Electronics Limited
34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United Kingdom
Tel: +44 (0)1670 707 111 • Fax: +44 (0)1670 707 222
E-mail: [email protected] • Website: www.Advel.co.uk
Certificate No: 018c to EN 54:Part 2 and 4: 1997
Certificate No: 544b to EN54-2: 1997+A1:2006 EN54-4: 1997+A1-2002+A2:2006
Control and indicating equipment
Certificated Products
Mx-1002
Mx-1004
Mx-1008
20 Oct 2014
2 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface board (option)
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
4 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface board (option)
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
8 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface board (option)
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
LPCB Ref.
No.
018c/02
018c/03
018c/04
9
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
Mx-1016
Mx-1032
Mx-1108
LPCB Ref.
No.
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
16 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface board (option)
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
32 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1629 Display board
C1632 16 Zone Expansion board
C1652 5A Power supply board
C1631 Repeater interface board (option)
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
8 zone conventional repeater unit
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface board
018c/05
018c/06
018c/R01
Mx-1116
16 zone conventional repeater unit
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface board
018c/R02
Mx-1132
32 zone conventional repeater unit
Incorporating as modular units:
C1627 Mother board
C1629 Display board
C1631 Repeater interface board
018c/R03
QuickZone
2 and 4 Zone conventional control and indicating equipment
QuickZone 2 (QZ-2)
Incorporating as modular units:
TPC A01- QuickZone 2 (QZ-2) main PCB applicable on 2 zone CIE only
TPC A02 QuickZone LED display PCB
PSM1.5 - 24 Power supply 1.5A rated
Certified with the following options with requirements from EN 54 Part 2:
7.8 Output to fire alarm devices
7.12.1 Dependency on more than one alarm signal type A
10 Test condition
QuickZone 4 (QZ-4)
Incorporating as modular units:
TPC A01- Quick Zone 4 (QZ-4) main PCB applicable on 4 zone CIE only
TPC A02 QuickZone LED display PCB
PSM1.5 - 24 Power supply 1.5A rated
Certified with the following options with requirements from EN 54 Part 2:
7.8 Output to fire alarm devices
7.12.1 Dependency on more than one alarm signal type A
10 Test condition
Note:
1. This product approval does not constitute compliance with the fire
detection and alarm systems requirements of EN 54-13.
4, 8 and 12 Zone conventional control and indicating equipment
QuickZoneXL 4 Conventional Control Panel (QZXL-4)
Incorporating as modular units:
544b/01
QuickZone XL
10
544b/02
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
TPCA01-X4 QuickZoneXL 4 Zone Main PCB
TPCA03 QuickZoneXL Display Board
PSM3.0-24 Power Supply
QuickZoneXL 8 Conventional Control Panel (QZXL-8)
Incorporating as modular units:
TPCA01-X4 QuickZoneXL 4 Zone Main PCB
TPCA03 QuickZoneXL Display Board
QZXL-ZEC QuickZoneXL Standard 4 Zone Extension Board
PSM3.0-24 Power Supply
QuickZoneXL 8 Conventional Control Panel (QZXL-8HS)
Incorporating as modular units:
TPCA01-X4 QuickZoneXL 4 Zone Main PCB
TPCA03 QuickZoneXL Display Board
QZXL-HSZEC QuickZoneXL High Spec 4 Zone Extension Board
PSM3.0-24 Power Supply
QuickZoneXL 12 Conventional Control Panel (QZXL-12)
TPCA01-X4 QuickZoneXL 4 Zone Main PCB
TPCA03 QuickZoneXLDisplay Board
QZXL-ZEO QuickZoneXL Standard 4 Zone Extension Board
QZXL-ZEC QuickZoneXL High Spec 4 Zone Extension Board
PSM3.0-24 Power Supply
QuickZoneXL 12 Zone Conventional Control Panel (QZXL-12HS)
TPCA01-X4 QuickZoneXL 4 Zone Main PCB
TPCA03 QuickZoneXL Display Board
QZXL-HSZEC Two QuickZoneXL Standard 4 Zone Extension Board
PSM3.0-24 Power Supply
Certified with the following options with requirements from EN 54 Part 2:
7.8 Output to fire alarm devices
7.11 Delays to outputs
7.12.1 Dependency on more than one alarm signal type A
7.12.2 Dependency on more than one alarm signal type B
7.12.3 Dependency on more than one alarm signal type C
10 Test condition
Note:
1. This product approval does not constitute compliance with the fire
detection and alarm systems requirements of EN 54-13.
Ajax Chubb Varel B.V.
Cruquiusweg 118, 1019 AK, Amsterdam, The Netherlands
Tel: +31205909500 • Fax: +31205909599
E-mail: [email protected] • Website: www.ajaxchubbvarel.nl
Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
809-250450
Two zone conventional control and indicating equipment
LPCB Ref.
No.
176b/10
Incorporating the units:
RPF0702005 Power supply PCB
SPF0724851 2 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
809-250451
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
10 Test condition
Four zone conventional control and indicating equipment
176b/11
Incorporating the units:
RPF0702005 Power supply PCB
SPF0724853 4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
20 Oct 2014
11
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
809-250452
LPCB Ref.
No.
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
10 Test condition
Eight zone conventional control and indicating equipment
176b/12
Incorporating the units:
RPF0702005 Power supply PCB
SPF0724855 8 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
10 Test condition
AMPAC Europe Limited
Unit 2, Waterbrook Estate, Waterbrook Road, Alton, Hampshire GU34 2UD, United Kingdom
Tel: +44 (0)1420 592070 • Fax: +44 (0)1420 592071
E-mail: [email protected] • Website: www.ampac.net
Certificate No: 952a to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 952b to EN 54-2: 1997 + A1: 2006, EN 54-4: 1998 + A1: 2002 + A2: 2006
Certificate No: 810a-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Control and Indicating Equipment
Certificated Products
Zonefinder
2 and 4 Zone conventional control and indicating equipment
2183-0201, 2 Zone conventional control and indicating equipment
LPCB Ref.
No.
810a/03
Incorporating as modular units:
TPC A01- E2 ZoneFinder two zone main PCB applicable on 2 zone CIE only
TPC A02 ZoneFinder LED display PCB
PSM1.5 - 24 Power supply 1.5A rated
Certified with the following options with requirements from EN 54 Part 2:
7.8 Output to fire alarm devices
7.12.1 Dependency on more than one alarm signal type A
10 Test condition
2183-0401, 4 Zone conventional control and indicating equipment
Incorporating as modular units:
TPC A01- E4 ZoneFinder four zone main PCB applicable on 4 zone CIE only
TPC A02 ZoneFinder LED display PCB
PSM1.5 - 24 Power supply 1.5A rated
Certified with the following options with requirements from EN 54 Part 2:
Zonefinder Plus
7.8 Output to fire alarm devices
7.12.1 Dependency on more than one alarm signal type A
10 Test condition
Note:
1. This product approval does not constitute compliance with the fire
detection and alarm systems requirements of EN 54-13.
2, 4, 6, 8 and 12 Zone conventional control and indicating equipment
810a/04
2183-0202, 2 Zone Conventional Control Panel
Incorporating as modular units:
TPCA01-X 2 ZoneFinder Plus 2 Zone Main PCB
12
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
TPCA03 ZoneFinder Plus Display Board
PSM3.0-24 Power Supply
2183-0402, 4 Zone Conventional Control Panel
Incorporating as modular units:
TPCA01-X4 ZoneFinder Plus 4 Zone Main PCB
TPCA03 ZoneFinder Plus Display Board
PSM3.0-24 Power Supply
2183-0604, 6 Zone Conventional Control Panel
Incorporating as modular units:
TPCA01-X2 ZoneFinder Plus 2 Zone Main PCB
TPCA03 ZoneFinder Plus Display Board
TPCA04-H ZoneFinder Plus High Spec 4 Zone Extension Board
PSM3.0-24 Power Supply
2183-0602, 6 Zone Conventional Control Panel
Incorporating as modular units:
TPCA01-X2 ZoneFinder Plus 2 Zone Main PCB
TPCA03 ZoneFinder Plus Display Board
TPCA04-S ZoneFinder Plus Standard 4 Zone Extension Board
PSM3.0-24 Power Supply
2183-0804, 8 Zone Conventional Control Panel
Incorporating as modular units:
TPCA01-X4 ZoneFinder Plus 4 Zone Main PCB
TPCA03 ZoneFinder Plus Display Board
TPCA04-H ZoneFinder Plus High Spec 4 Zone Extension Board
PSM3.0-24 Power Supply
2183-0802, 8 Zone Conventional Control Panel
Incorporating as modular units:
TPCA01-X4 ZoneFinder Plus 4 Zone Main PCB
TPCA03 ZoneFinder Plus Display Board
TPCA04-S ZoneFinder Plus Standard 4 Zone Extension Board
PSM3.0-24 Power Supply
2183-1204, 12 Zone Conventional Control Panel
Incorporating as modular units:
TPCA01-X4 ZoneFinder Plus 4 Zone Main PCB
TPCA03 ZoneFinder Plus Display Board
TPCA04-S Qty 2x ZoneFinder Plus High Spec 4 Zone Extension Board
TPCA04-H ZoneFinder Plus High Spec 4 Zone Extension Board
PSM3.0-24 Power Supply
2183-1202, 12 Zone Conventional Control Panel
Incorporating as modular units:
TPCA01-X4 ZoneFinder Plus 4 Zone Main PCB
TPCA03 ZoneFinder Plus Display Board
TPCA04-S ZoneFinder Plus Standard 4 Zone Extension Board
PSM3.0-24 Power Supply
2183-1206 12 Zone Conventional Control Panel
Incorporating as modular units:
TPCA01-X4 ZoneFinder Plus 4 Zone Main PCB
TPCA03 ZoneFinder Plus Display Board
TPCA04-H Qty 2x ZoneFinder Plus High Spec 4 Zone Extension Board
PSM3.0-24 Power Supply
Certified with the following options with requirements from EN 54 Part 2:
7.8 Output to fire alarm devices
7.11 Delays to outputs
7.12.1 Dependency on more than one alarm signal type A
20 Oct 2014
13
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LoopSense 8281-0105
LPCB Ref.
No.
7.12.2 Dependency on more than one alarm signal type B
7.12.3 Dependency on more than one alarm signal type C
10 Test condition
Note:
1. This product approval does not constitute compliance with the fire
detection and alarm systems requirements of EN 54-13.
One loop, 32 Zone analogue addressable control and indicating equipment.
952a/01
Incorporating the following units:
BRD82MBA
BRD82ZICC
PSU2397
ASS82ZICC
Main Termination Board
Zone Interface & Control Card
Power Supply Unit
Zone Indicator & LCD Assembly (8210)
Certificated with the following options with requirements from EN54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.11
Delay to outputs
7.12.1
Dependencies on more than one alarm signal Type A
7.12.2
Dependencies on more than one alarm signal Type B
7.12.3
Dependencies on more than one alarm signal Type C
8.3
Fault signal from points
8.9
Output to fault warning routing equipment
9.5
Disablement of each addressable point
10
Test condition
Note:
1. This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13.
LoopSense 8281-0205
Two loop, 32 Zone analogue addressable control and indicating equipment.
952a/02
Incorporating the following units:
BRD82MBA
BRD82ZICC
PSU2397
8210-0001
BRD82LSD
ASS82ZICC
Main Termination Board
Zone Interface & Control Card
Power Supply Unit
2nd loop activation Key
Loop Activation Board
Zone Indicator & LCD Assembly (8210)
Certificated with the following options with requirements from EN54-2:
8681-0108 FireFinder Plus
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.11
Delay to outputs
7.12.1
Dependencies on more than one alarm signal Type A
7.12.2
Dependencies on more than one alarm signal Type B
7.12.3
Dependencies on more than one alarm signal Type C
8.3
Fault signal from points
8.9
Output to fault warning routing equipment
9.5
Disablement of each addressable point
10
Test condition
Note:
1. This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13.
One loop, 32 Zone analogue addressable control and indicating equipment
952b/01
Incorporating as modular units:
BRD68BPSC4-A FFP
BRD86DLTB4-A FFP
BRD86FPB5-B FFP
BRD86MBA4-A FFP
BRD86MCPU4-B FFP
BRD43ZAMC2-A
PSU1888
Brigade & Power supply control board (8610)
Dual loop termination board (8610)
Front panel board EN54 (8610)
Main board LCD (8610)
Main 64MB CPU card (8610)
32 Zone alarm MIMIC internal card (4310)
Power supply 5A (8610)
Optional Modules:
14
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
BRD43EZC2-A 8 Zone conventional module (4310)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
8681-0208 FireFinder Plus
7.8
Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routine equipment
7.11
Delay to outputs
7.12.1 Dependencies on more than one alarm signal - Type A
7.12.2 Dependencies on more than one alarm signal - Type B
7.12.3 Dependencies on more than one alarm signal - Type C
8.3
Fault signal from points
8.9
Output to fault warning routing equipment
9.5
Disablement of each addressable point
10
Test condition
Two loop, 32 Zone analogue addressable control and indicating equipment
952b/02
Incorporating as modular units:
BRD68BPSC4-A FFP
BRD86DLTB4-A FFP
BRD86FPB5-B FFP
BRD86MBA4-A FFP
BRD86MCPU4-B FFP
BRD86SCB3-A FFP
BRD43ZAMC2-A
PSU1888
Brigade & Power supply control board (8610)
Dual loop termination board (8610)
Front panel board EN54 (8610)
Main board LCD (8610)
Main 64MB CPU card (8610)
Slave CPU card (8610)
32 Zone alarm MIMIC internal card (4310)
Power supply 5A (8610)
Optional Modules:
BRD43EZC2-A
BRD43ZAMC2-A
8 Zone conventional module (4310)
32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
8681-0308 FireFinder Plus
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routine equipment
7.11
Delay to outputs
7.12.1 Dependencies on more than one alarm signal - Type A
7.12.2 Dependencies on more than one alarm signal - Type B
7.12.3 Dependencies on more than one alarm signal - Type C
8.3
Fault signal from points
8.9
Output to fault warning routing equipment
9.5
Disablement of each addressable point
10
Test condition
Three loop, 32 Zone analogue addressable control and indicating equipment
952b/03
Incorporating as modular units:
BRD68BPSC4-A FFP
BRD86DLTB4-A FFP
BRD86FPB5-B FFP
BRD86MBA4-A FFP
BRD86MCPU4-B FFP
BRD86SCB3-A FFP
BRD43ZAMC2-A
PSU1888
Brigade & Power supply control board (8610)
Two Dual loop termination boards (8610)
Front panel board EN54 (8610)
Main board LCD (8610)
Main 64MB CPU card (8610)
Two Slave CPU cards (8610)
32 Zone alarm MIMIC internal card (4310)
Power supply 5A (8610)
Optional Modules:
BRD86DLTB4-A FFP
BRD86SCB3-A FFP
BRD43EZC2-A
BRD43ZAMC2-A
Dual loop termination board (8610)
Slave CPU cards (8610)
8 Zone conventional module (4310)
32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.11
7.12.1
20 Oct 2014
Output to fire alarm devices
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routine equipment
Delay to outputs
Dependencies on more than one alarm signal - Type A
15
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.12.2
7.12.3
8.3
8.9
9.5
10
Dependencies on more than one alarm signal - Type B
Dependencies on more than one alarm signal - Type C
Fault signal from points
Output to fault warning routing equipment
Disablement of each addressable point
Test condition
Incorporating as modular units:
BRD68BPSC4-A FFP Brigade & Power supply control board (8610)
BRD86DLTB4-A FFP Two Dual loop termination boards (8610)
BRD86FPB5-B FFP Front panel board EN54 (8610)
BRD86MBA4-A FFP Main board LCD (8610)
BRD86MCPU4-B FFP Main 64MB CPU card (8610)
BRD86SCB3-A FFP Two Slave CPU cards (8610)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
PSU1888 Power supply 5A (8610)
Optional Modules:
BRD86DLTB4-A FFP Dual loop termination board (8610)
BRD86SCB3-A FFP Slave CPU cards (8610)
BRD43EZC2-A 8 Zone conventional module (4310)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
8681-0408 FireFinder Plus
7.8 Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routine equipment
7.11 Delay to outputs
7.12.1 Dependencies on more than one alarm signal - Type A
7.12.2 Dependencies on more than one alarm signal - Type B
7.12.3 Dependencies on more than one alarm signal - Type C
8.3 Fault signal from points
8.9 Output to fault warning routing equipment
9.5 Disablement of each addressable point
10 Test condition
Four loop, 32 Zone analogue addressable control and indicating equipment
952b/04
Incorporating as modular units:
BRD68BPSC4-A FFP
BRD86DLTB4-A FFP
BRD86FPB5-B FFP
BRD86MBA4-A FFP
BRD86MCPU4-B FFP
BRD86SCB3-A FFP
BRD43ZAMC2-A
PSU1888
Brigade & Power supply control board (8610)
Two Dual loop termination boards (8610)
Front panel board EN54 (8610)
Main board LCD (8610)
Main 64MB CPU card (8610)
Three Slave CPU cards (8610)
32 Zone alarm MIMIC internal card (4310)
Power supply 5A (8610)
Optional Modules:
BRD86DLTB4-A FFP
BRD86SCB3-A FFP
BRD43EZC2-A
BRD43ZAMC2-A
Dual loop termination board (8610)
Slave CPU cards (8610)
8 Zone conventional module (4310)
32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.11
7.12.1
7.12.2
7.12.3
8.3
8.9
9.5
10
16
Output to fire alarm devices
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routine equipment
Delay to outputs
Dependencies on more than one alarm signal - Type A
Dependencies on more than one alarm signal - Type B
Dependencies on more than one alarm signal - Type C
Fault signal from points
Output to fault warning routing equipment
Disablement of each addressable point
Test condition
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
AMPAC Technologies PTY Ltd
7 Ledgar Road, Balcatta 6021, Australia
Tel: +618 (9242) 3333 • Fax: +618 (9242) 3334
E-mail: [email protected] • Website: www.ampac.net
Certificate No: 966a to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 966b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1998 + A1: 2002 + A2: 2006
Certificated Products
LoopSense 8281-0105
One loop, 32 Zone analogue addressable control and indicating equipment.
LPCB Ref.
No.
966a/01
Incorporating the following units:
BRD82MBA
BRD82ZICC
PSU2397
ASS82ZICC
LoopSense 8281-0205
Main Termination Board
Zone Interface & Control Card
Power Supply Unit
Zone Indicator & LCD Assembly (8210)
Certificated with the following options with requirements from EN54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.11
Delay to outputs
7.12.1
Dependencies on more than one alarm signal - Type A
7.12.2
Dependencies on more than one alarm signal - Type B
7.12.3
Dependencies on more than one alarm signal - Type C
8.3
Fault signal from points
8.9
Output to fault warning routing equipment
9.5
Disablement of each addressable point
10
Test condition
Note:
1. This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13.
Two loop, 32 Zone analogue addressable control and indicating equipment.
966a/02
Incorporating the following units:
BRD82MBA
BRD82ZICC
PSU2397
8210-0001
BRD82LSD
ASS82ZICC
Main Termination Board
Zone Interface & Control Card
Power Supply Unit
2nd loop activation Key
Loop Activation Board
Zone Indicator & LCD Assembly (8210)
Certificated with the following options with requirements from EN54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.11
Delay to outputs
7.12.1
Dependencies on more than one alarm signal Type A
7.12.2
Dependencies on more than one alarm signal Type B
7.12.3
Dependencies on more than one alarm signal Type C
8.3
Fault signal from points
8.9
Output to fault warning routing equipment
9.5
Disablement of each addressable point
10
Test condition
Note:
1. This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13.
8681-0108 FireFinder Plus
One loop, 32 Zone analogue addressable control and indicating equipment
966b/01
Incorporating as modular units:
BRD68BPSC4-A FFP Brigade & Power supply control board (8610)
BRD86DLTB4-A FFP Dual loop termination board (8610)
BRD86FPB5-B FFP Front panel board EN54 (8610)
BRD86MBA4-A FFP Main board LCD (8610)
20 Oct 2014
17
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
BRD86MCPU4-B FFP Main 64MB CPU card (8610)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
PSU1888 Power supply 5A (8610)
Optional Modules:
BRD43EZC2-A 8 Zone conventional module (4310)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
8681-0208 FireFinder Plus
7.8 Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routine equipment
7.11 Delay to outputs
7.12.1 Dependencies on more than one alarm signal - Type A
7.12.2 Dependencies on more than one alarm signal - Type B
7.12.3 Dependencies on more than one alarm signal - Type C
8.3 Fault signal from points
8.9 Output to fault warning routing equipment
9.5 Disablement of each addressable point
10 Test condition
Two loop, 32 Zone analogue addressable control and indicating equipment
966b/02
Incorporating as modular units:
BRD68BPSC4-A FFP Brigade & Power supply control board (8610)
BRD86DLTB4-A FFP Dual loop termination board (8610)
BRD86FPB5-B FFP Front panel board EN54 (8610)
BRD86MBA4-A FFP Main board LCD (8610)
BRD86MCPU4-B FFP Main 64MB CPU card (8610)
BRD86SCB3-A FFP Slave CPU card (8610)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
PSU1888 Power supply 5A (8610)
Optional Modules:
BRD43EZC2-A 8 Zone conventional module (4310)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
8681-0308 FireFinder Plus
7.8 Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routine equipment
7.11 Delay to outputs
7.12.1 Dependencies on more than one alarm signal - Type A
7.12.2 Dependencies on more than one alarm signal - Type B
7.12.3 Dependencies on more than one alarm signal - Type C
8.3 Fault signal from points
8.9 Output to fault warning routing equipment
9.5 Disablement of each addressable point
10 Test condition
Incorporating as modular units:
966b/03
BRD68BPSC4-A FFP Brigade & Power supply control board (8610)
BRD86DLTB4-A FFP Two Dual loop termination boards (8610)
BRD86FPB5-B FFP Front panel board EN54 (8610)
BRD86MBA4-A FFP Main board LCD (8610)
BRD86MCPU4-B FFP Main 64MB CPU card (8610)
BRD86SCB3-A FFP Two Slave CPU cards (8610)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
PSU1888 Power supply 5A (8610)
Optional Modules:
BRD86DLTB4-A FFP Dual loop termination board (8610)
BRD86SCB3-A FFP Slave CPU cards (8610)
BRD43EZC2-A 8 Zone conventional module (4310)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
18
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.9.2 Alarm confirmation input from fire alarm routine equipment
7.11 Delay to outputs
7.12.1 Dependencies on more than one alarm signal - Type A
7.12.2 Dependencies on more than one alarm signal - Type B
7.12.3 Dependencies on more than one alarm signal - Type C
8.3 Fault signal from points
8.9 Output to fault warning routing equipment
9.5 Disablement of each addressable point
10 Test condition
Incorporating as modular units:
BRD68BPSC4-A FFP Brigade & Power supply control board (8610)
BRD86DLTB4-A FFP Two Dual loop termination boards (8610)
BRD86FPB5-B FFP Front panel board EN54 (8610)
BRD86MBA4-A FFP Main board LCD (8610)
BRD86MCPU4-B FFP Main 64MB CPU card (8610)
BRD86SCB3-A FFP Two Slave CPU cards (8610)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
PSU1888 Power supply 5A (8610)
Optional Modules:
BRD86DLTB4-A FFP Dual loop termination board (8610)
BRD86SCB3-A FFP Slave CPU cards (8610)
BRD43EZC2-A 8 Zone conventional module (4310)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
8681-0408 FireFinder Plus
7.8 Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routine equipment
7.11 Delay to outputs
7.12.1 Dependencies on more than one alarm signal - Type A
7.12.2 Dependencies on more than one alarm signal - Type B
7.12.3 Dependencies on more than one alarm signal - Type C
8.3 Fault signal from points
8.9 Output to fault warning routing equipment
9.5 Disablement of each addressable point
10 Test condition
Four loop, 32 Zone analogue addressable control and indicating equipment
966b/04
Incorporating as modular units:
BRD68BPSC4-A FFP Brigade & Power supply control board (8610)
BRD86DLTB4-A FFP Two Dual loop termination boards (8610)
BRD86FPB5-B FFP Front panel board EN54 (8610)
BRD86MBA4-A FFP Main board LCD (8610)
BRD86MCPU4-B FFP Main 64MB CPU card (8610)
BRD86SCB3-A FFP Three Slave CPU cards (8610)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
PSU1888 Power supply 5A (8610)
Optional Modules:
BRD86DLTB4-A FFP Dual loop termination board (8610)
BRD86SCB3-A FFP Slave CPU cards (8610)
BRD43EZC2-A 8 Zone conventional module (4310)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routine equipment
7.11 Delay to outputs
7.12.1 Dependencies on more than one alarm signal - Type A
7.12.2 Dependencies on more than one alarm signal - Type B
7.12.3 Dependencies on more than one alarm signal - Type C
8.3 Fault signal from points
8.9 Output to fault warning routing equipment
9.5 Disablement of each addressable point
10 Test condition
20 Oct 2014
19
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Application Solutions (Safety and Security) Ltd, East Sussex, United Kingdom
Unit 17, Cliffe Industrial Estate, Lewes, East Sussex BN8 6JL, United Kingdom
Tel: +44 (0) 1273 405411 • Fax: +44(0) 1273 405415
E-mail: [email protected] • Website: www.asl-control.co.uk
Certificate No: 1043a to EN 54-16: 2008 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
ASL Rack mount voice
alarm system
Incorporating the following modules:
VAR8-ACU(EN54) Network master 8x8 router
VAR8(EN54)
Standalone 8x8 router
VAR8-E(EN54)
Standalone 8x8 router with expansion board
VAR4(EN54)
Standalone 4x4 router
VAR12(EN54)
Standalone 12x12 router
VAR20(EN54)
Standalone 20x20 router
VAR-NIA
Network Interface Adaptor
VIPEDIA-12
Professional Sound Life-Safety Digital Audio System
BOA01
DIN Rail Mount
BOA02
RJ45 Break Out Adaptor - Four Port - Straight
Through VAR8 Optional Modules
LPCB Ref.
No.
1043a/01
VAR8 Optional modules:
EFI01
Analogue input and digital output board
GENT Interface
Interface for VAR8-E to GENT Fire Loop
VAR-ANIC
Network interface for VAR8(EN54), VAR8-E(EN54) and
VAR8-ACU(EN54)
VAR8-EXP8
Converts VAR8(EN54) to VAR8-E(EN54)
V400
V400
Amplifier frame:
Amplifier frame for housing M series amplifiers and amplifier interfaces
M series amplifiers:
M100
100W Amplifier
M200
200W Amplifier
M400
400W Amplifier
Amplifier interfaces for V400 mainframe:
LSDDC Dual DC line surveillance interface with loop return option
SSINT
Standby amplifier interface
X400 Amplifier frame:
X400
Amplifier frame for housing MX series amplifiers
MX series amplifiers:
MX100
100W Amplifier
MX200
200W Amplifier
MX400
400W Amplifier
Power supply:
BPC65
65AH output power supply
BPC130 130AH Output power supply
BDIST
Battery distribution terminals
MDIST
Main distribution panel
Optional modules:
BMB01
FMS1
FMS5
FMS10
FMS20
EMS01
EMS01-EC
EMS01-MT
EAP01
MT01
20
Remote I/O expander unit
Firemans microphone - All call
Zoneable Firemans remote microphone - 5 buttons
Zoneable Firemans remote microphone - 10 buttons
Zoneable Firemans remote microphone - 20 buttons
Emergency microphone and accessible Mimic display for routers
Emergency microphone and accessible Mimic display for routers
with euro-cylinder lock
EMS01 with an all-call button used to trigger an evacuation
message
Emergency access point - All call emergency microphone
Voice alarm manual trigger
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
EMS01(MK2)
EMS01-EC(MK2)
EMS10
EMS10-EC
EMS20
EMS20-EC
EMS30
EMS40
EMS50
EMX30
MPS01-F
MPS01-G
MPS10-F
MPS10-G
MPS20-F
MPS20-G
MPS30-F
MPS30-G
MPS40-F
MPS40-G
MPS50-F
MPS50-G
MPX10
MPS01-MB
Emergency microphone station - All call
Emergency microphone station - All call with euro-cylinder lock
Emergency microphone station - 10 Button
Emergency microphone station - 10 Button with euro-cylinder lock
Emergency microphone station - 20 Button
Emergency microphone station - 20 Button with euro-cylinder lock
Emergency microphone station - 30 Button
Emergency microphone station - 40 Button
Emergency microphone station - 50 Button
Expansion module for EMS20 - 30 Button
Desk paging and emergency microphone - 1 Button - Fist mic
Desk paging and emergency microphone - 1 Button Gooseneck mic
Desk paging and emergency microphone - 10 Button - Fist mic
Desk paging and emergency microphone - 10 Button Gooseneck mic
Desk paging and emergency microphone - 20 Button - Fist mic
Desk paging and emergency microphone - 20 Button Gooseneck mic
Desk paging and emergency microphone - 30 Button - Fist mic
Desk paging and emergency microphone - 30 Button Gooseneck mic
Desk paging and emergency microphone - 40 Button - Fist mic
Desk paging and emergency microphone - 40 Button Gooseneck mic
Desk paging and emergency microphone - 50 Button - Fist mic
Desk paging and emergency microphone - 50 Button Gooseneck mic
Microphone expansion module for MPS01 - 10 Button
Wall mount bracket kit for MPS01
Certified with the following options with requirements from EN 54 Part 16:
7.6.2
Manual silencing of voice alarm condition
7.7.2
Manual reset of the voice alarm condition
7.9
Voice alarm condition output
8.3
Indication of faults related to the transmission path to the CIE (Not applicable
on the GENT Interface)
8.4
Indication of faults related to voice alarm zones
10.0
Voice Alarm Manual control
12.0
Emergency microphone(s)
13.14
Redundant power amplifiers
Bardic by Honeywell (Novar Systems Ltd)
140 Waterside Road, Hamilton Industrial Estate, Leicester LE5 1TN, United Kingdom
Tel: +44 (0) 116 246 2212 • Fax: +44 (0) 116 246 2210
Website: www.bardic.co.uk
Certificate No: 154g-(cl-3) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
Zircon 2 Zone
002-509-229 Bardic Zircon, 2 zone, region 2, black grey
Incorporating the following units:
020-747 8-way relay kit
020-772 4-way monitored sounder kit
LPCB Ref.
No.
154g/06
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Output to automatic fire protection equipment: Type A
7.10.3
Output to automatic fire protection equipment: Type C
7.10.4
Fault monitoring of fire protection equipment
7.11.1
Delays to outputs
7.11.2
Manual or automatic switching of delays to outputs
20 Oct 2014
21
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
Zircon 4 Zone
Zircon 8 Zone
LPCB Ref.
No.
7.12.2
Dependency on more than one alarm signal: Type B
8.9
Output to fault warning routing equipment
10
Test condition
002-509-249 Bardic Zircon, 4 zone, region 2, black grey
Incorporating the following units:
020-747 8-way relay kit
020-772 4-way monitored sounder kit
154g/07
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Output to automatic fire protection equipment: Type A
7.10.3
Output to automatic fire protection equipment: Type C
7.10.4
Fault monitoring of fire protection equipment
7.11.1
Delays to outputs
7.11.2
Manual or automatic switching of delays to outputs
7.12.2
Dependency on more than one alarm signal: Type B
8.9
Output to fault warning routing equipment
10
Test condition
002-509-289 Bardic Zircon, 8 zone, region 2, black grey
Incorporating the following units:
020-747 8-way relay kit
020-772 4-way monitored sounder kit
154g/08
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Output to automatic fire protection equipment: Type A
7.10.3
Output to automatic fire protection equipment: Type C
7.10.4
Fault monitoring of fire protection equipment
7.11.1
Delays to outputs
7.11.2
Manual or automatic switching of delays to outputs
7.12.2
Dependency on more than one alarm signal: Type B
8.9
Output to fault warning routing equipment
10
Test condition
Beijing Leader Huaxin Electronics Co. Ltd
No. 17 Rongjing Eastern Road, Economy & Technology Developed Area, Beijing 100176, China
Tel: +86 10 67876681 • Fax: +86 10 67863972
E-mail: [email protected] • Website: www.beijingleader.com.cn
Certificate No: 987b to EN 54-2: 1997+A1:2006EN 54-4:1997+A1:2006
Control and indicating equipment
Biamp Systems Corporation
9300 S.W. Gemini Drive, Beaverton, Oregon 97008, USA
Tel: +1 503 718 9212 • Fax: +1 503 626 0281
Website: www.biamp.com
Certificate No: 977a to EN 54-16: 2008
Certificated Products
Vocia VACIE
Voice Alarm Control and Indicating Equipment
LPCB Ref.
No.
977a/01
Incorporating:
LSI-16 / LSI-16e Life Safety Interface:
22
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
700-P630-9 LSI-16 / LSI-16e Main Board
700-P632-9 LSI-16 / LSI-16e Display Board
700-P675-9 IM-16 Input Module
700-P644-9 LSI-16 / LSI-16e Power Supply Board
VA-8600c Amplifier:
700-0646-9 VA-8600 AM-600c Amplifier Module
700-0601-9 VA-8600 NM-1 Network Module
700-0598-9 VA-8600 Back Plane Board
700-0599-9 VA-8600 Power Supply Board
700-0633-9 VA-8600 Capacitor Board
700-0629-9 VA-8600 AC Inlet Board
700-0602-9 VA-8600 Display Board
700-P622-9 VA-8600 Device ID Board
700-P800-9 VFOM-1 Voice Fail Over Module
VA-4030e Amplifier:
700-0675-9 VPA-1 Amplifier Module
700-0677-9 VSW-1 Transformer Switch Board
700-P680-9 VNM-1 Network Module
700-0687-9 VAS-1 Aux DC Power Supply
700-0672-9 EIC-4 Input Module
700-P681-9 VAD-1 Display Board
VA-4030 Amplifier:
700-0675-9 VPA-1 Amplifier Module
700-0677-9 VSW-1 Transformer Switch Board
700-P680-9 VNM-1 Network Module
700-P684-9 VAD-2 Display Board
VA-2060e Amplifier:
700-0676-9 VPA-2 Amplifier Module
700-0686-9 VSW-1 Transformer Switch Board
700-P680-9 VNM-1 Network Module
700-0687-9 VAS-1 Aux DC Power Supply
700-0689-9 EIC-2 Input Module
700-P685-9 VAD-3 Display Board
VA-2060 Amplifier:
700-0676-9 VPA-2 Amplifier Module
700-0686-9 VSW-1 Transformer Switch Board
700-P680-9 VNM-1 Network Module
700-P686-9 VAD-4 Display Board
WS-4 (EWS-4) Paging Micro phone:
700-P625-9 WS Main Board
700-P676-9 WS-4 (EWS-4) Switch Board
WS-10 (EWS-10) Paging Microphone:
700-P625-9 WS Main Board
700-P776-9 WS-10 (EWS-10) Switch Board
CI-1 Control Interface:
700-P669-9 CI-1 Main Board
Certified with the following options with requirements from EN 54-16:
7.3 Audible warning
7.5 Phased evacuation
7.9 Voice alarm condition output
8.3 Indication of faults related to the transmission path to the CIE
12 Emergency microphone
13.14 Redundant power amplifiers
Note: The certification is conditional upon the Vocia VACIE being supplied with power
from power supplies that meet the specifications detailed in the VOCIA Reference Guide,
and comply with the requirements of EN 54-4.
20 Oct 2014
23
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Bosch Security Systems BV
Torenalle 49, Eindhoven 5617BA, The Netherlands
Tel: +31 76 5721 240 • Fax: +31 76 5716 626
E-mail: [email protected] • Website: www.boschsecurity.com
Certificate No: 1054a-(cl-1) to EN 54-16: 2008
Certificated Products
PROMATRIX 8000
LPCB Ref.
No.
1054a/01
Voice Alarm System
Incorporating the following modules:
DPM 8016 Promatrix controller
PXM-MM2 Dual-channel playback module
DPM AO-1 Analog audio output module
DPM UI-1 Universal audio input module
DPA 8150 1 x 500W Power amplifier
DPA 8225 2 x 250W Power amplifier
DPA 8412 4 x 125W Power amplifier
DPC 8015 Call station
DCS 400 DCS 19" Mounting Frame
DCS 801R Conrtroller Module
DCS 406R Shield Module
DCS 407R AF Relay Module Ext
DCS 408R Loudspeaker relay Module
DCS 409R AF Relay Module
DCS 412R Logic Input Module
DCS 416R Analog I/O Module
NRS90231 Key lock switch
EB DPC Emergency button DPC 8000 series
DPC 8120 Call station extension
LBB1965 Plena message manager
PLN-1EOL End Of Line Board
EOL 8001 End Of Line Board
P 64 Digital Audio Matrix
N8000 Netmax System Controller
AI-1 Analog Audio Input Module
AO-1 Analog Audio Output Module
MI-1 Microphone Input Module
CM-1 Cobranet Network Module
DM-1 Dante Network Module
DSP-1 DSP Extension Module 300 Mips
DSP-2V2 DSP Extension Module 1500 Mips
DSA 8405 4 X 500 W Power Amplifier
DSA 8410 4 X 1000 W Power Amplifier
DSA 8805 8 X 500 W Power Amplifier
CPS4.5 4 X 500 W Power Amplifier
CPS4.10 4 X 1000 W Power Amplifier
CPS8.5 8 X 500 W Power Amplifier
RCM-810 Remote Control Module
LML-1 Line Measuring Load
LML-1v2 Line Measuring Load
Certified with the following options with requirements from EN 54 Part 16:
7.5 Phase evacuation
7.6.2 Manual silencing of the voice alarm condition
7.7.2 Manual reset of the voice alarm condition
7.9 Voice alarm condition output
8.3 Indication of faults related to the transmission path to the CIE
8.4 Indication of faults related to voice alarm zones
10 Voice alarm manual control
12 Emergency microphone(s)
13.14 Redundant power amplifier
Note:
The certificate is conditional upon the PROMATRIX 8000 VOICE ALARM SYSTEM being
supplied with power from power supplies that meet the power specifications detailed in
the owner manuals of the certified modules, and which complies with the requirements of
24
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
EN54-4.
Building Protection Systems (NI) Limited
1 Pilot's View, Sydenham Business Park, Heron Road, Belfast Harbour Estate, Belfast BT3 9LE, Ireland
Tel: 00442890455111 • Fax: 00442890466111
E-mail: [email protected] • Website: www.bpsni.co.uk
Certificate No: 154g-(cl-4) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
Mach 2.8
Basic Equipment Kit, (BEK): Modular analogue addressable
control and indicating equipment
020-538-501
Basic Equipment Kit, Group 0
LPCB Ref.
No.
154g/01
Incorporating the following as modular units:
Enclosures:
020-472-009
020-473-009
020-474-009
020-475-009
020-476-009
020-480-501
020-481-009
020-508-009
020-509-009
020-576
020-577
020-621
020-621-009
020-541-501
Backbox Kit Standard
Backbox Kit Extended, Black / Grey
Backbox Kit Extended Deep, Black / Grey
Backbox Kit Double Extended, Black / Grey
Backbox Kit Double Extended Deep, Black / Grey
Cover Kit Main Moulded, Black / Grey
Cover Kit Extended Moulded, Black / Grey
Backbox Extension Standard Assembly Black / Grey
Backbox Extension Deep Assembly Black / Grey
Main Cover, Stainless Steel
Extension Cover Stainless Steel
Zone Extension Cover, Stainless / Steel
256 Zone Extension Cover, Black / Grey
PSU7A / 78Ah Battery Enclosure
Modules:
020-559-001
Zone Extension Chassis Kit 1-64 Zone C/W Display Module
020-559-002
Zone Extension Chassis Kit 65-128 Zone C/W Display Module
020-612 Double Extended Chassis Kit 256 Zone
020-708-009
Extension Chassis with Printer
020-644-009
Printer Assembly
020-588 Notifier Dual Loop Interface Board, (LIB)
020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB)
020-478 RS232 Interface
020-479 RS485 Interface
020-648 PSU3A
020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)
020-548 PSU7A Status Indication
020-543 Dual Transmission Path / Booster, PSU Interface
020-773 Routing Termination Unit (DEOL)
020-877 Extinguishing Interface Module M221-SI
020-643 ID²net Fibre Optic Interface Kit
020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel
Notes:
1. Products are available in language variant as follows:
Group 0: English with English manuals
Mach 2.8
2. Fixed build products incorporate a corresponding Basic Equipment Kit.
Fixed build 2 loop analogue addressable
control and indicating equipment
002-530
2 Loop, PSU3A, Group 0
154g/01
Incorporating the following as modular units:
Enclosures:
20 Oct 2014
25
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
020-472-009
020-473-009
020-474-009
020-475-009
020-476-009
020-480-501
020-481-009
020-508-009
020-509-009
020-576
020-577
020-621
020-621-009
020-541-501
Backbox Kit Standard
Backbox Kit Extended, Black / Grey
Backbox Kit Extended Deep, Black / Grey
Backbox Kit Double Extended, Black / Grey
Backbox Kit Double Extended Deep, Black / Grey
Cover Kit Main Moulded, Black / Grey
Cover Kit Extended Moulded, Black / Grey
Backbox Extension Standard Assembly Black / Grey
Backbox Extension Deep Assembly Black / Grey
Main Cover, Stainless Steel
Extension Cover Stainless Steel
Zone Extension Cover, Stainless / Steel
256 Zone Extension Cover, Black / Grey
PSU7A / 78Ah Battery Enclosure
Modules:
020-559-001
Zone Extension Chassis Kit 1-64 Zone C/W Display Module
020-559-002
Zone Extension Chassis Kit 65-128 Zone C/W Display Module
020-612 Double Extended Chassis Kit 256 Zone
020-708-009
Extension Chassis with Printer
020-644-009
Printer Assembly
020-588 Notifier Dual Loop Interface Board, (LIB)
020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB)
020-478 RS232 Interface
020-479 RS485 Interface
020-648 PSU3A
020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)
020-548 PSU7A Status Indication
020-543 Dual Transmission Path / Booster, PSU Interface
020-773 Routing Termination Unit (DEOL)
020-877 Extinguishing Interface Module M221-SI
020-643 ID²net Fibre Optic Interface Kit
020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel
Notes:
1. Products are available in language variant as follows:
Group 0: English with English manuals
Mach 2.8
2. Fixed build products incorporate a corresponding Basic Equipment Kit.
Fixed build 4 loop analogue addressable
control and indicating equipment
020-905
4 Loop, PSU7A, Group 0
154g/01
Incorporating the following as modular units:
Enclosures:
020-472-009
020-473-009
020-474-009
020-475-009
020-476-009
020-480-501
020-481-009
020-508-009
020-509-009
020-576
020-577
020-621
020-621-009
020-541-501
Backbox Kit Standard
Backbox Kit Extended, Black / Grey
Backbox Kit Extended Deep, Black / Grey
Backbox Kit Double Extended, Black / Grey
Backbox Kit Double Extended Deep, Black / Grey
Cover Kit Main Moulded, Black / Grey
Cover Kit Extended Moulded, Black / Grey
Backbox Extension Standard Assembly Black / Grey
Backbox Extension Deep Assembly Black / Grey
Main Cover, Stainless Steel
Extension Cover Stainless Steel
Zone Extension Cover, Stainless / Steel
256 Zone Extension Cover, Black / Grey
PSU7A / 78Ah Battery Enclosure
Modules:
020-559-001
Zone Extension Chassis Kit 1-64 Zone C/W Display Module
020-559-002
Zone Extension Chassis Kit 65-128 Zone C/W Display Module
020-612 Double Extended Chassis Kit 256 Zone
020-708-009
Extension Chassis with Printer
020-644-009
Printer Assembly
020-588 Notifier Dual Loop Interface Board, (LIB)
020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB)
020-478 RS232 Interface
020-479 RS485 Interface
26
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
020-648
020-579
020-548
020-543
020-773
020-877
020-643
020-647
PSU3A
PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)
PSU7A Status Indication
Dual Transmission Path / Booster, PSU Interface
Routing Termination Unit (DEOL)
Extinguishing Interface Module M221-SI
ID²net Fibre Optic Interface Kit
ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel
Notes:
1. Products are available in language variant as follows:
Group 0: English with English manuals
Mach 2.8
2. Fixed build products incorporate a corresponding Basic Equipment Kit.
Fixed build 6 loop analogue addressable
control and indicating equipment
020-906
6 Loop, PSU7A, Group 0
154g/01
Incorporating the following as modular units:
Enclosures:
020-472-009
020-473-009
020-474-009
020-475-009
020-476-009
020-480-501
020-481-009
020-508-009
020-509-009
020-576
020-577
020-621
020-621-009
020-541-501
Backbox Kit Standard
Backbox Kit Extended, Black / Grey
Backbox Kit Extended Deep, Black / Grey
Backbox Kit Double Extended, Black / Grey
Backbox Kit Double Extended Deep, Black / Grey
Cover Kit Main Moulded, Black / Grey
Cover Kit Extended Moulded, Black / Grey
Backbox Extension Standard Assembly Black / Grey
Backbox Extension Deep Assembly Black / Grey
Main Cover, Stainless Steel
Extension Cover Stainless Steel
Zone Extension Cover, Stainless / Steel
256 Zone Extension Cover, Black / Grey
PSU7A / 78Ah Battery Enclosure
Modules:
020-559-001
Zone Extension Chassis Kit 1-64 Zone C/W Display Module
020-559-002
Zone Extension Chassis Kit 65-128 Zone C/W Display Module
020-612 Double Extended Chassis Kit 256 Zone
020-708-009
Extension Chassis with Printer
020-644-009
Printer Assembly
020-588 Notifier Dual Loop Interface Board, (LIB)
020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB)
020-478 RS232 Interface
020-479 RS485 Interface
020-648 PSU3A
020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)
020-548 PSU7A Status Indication
020-543 Dual Transmission Path / Booster, PSU Interface
020-773 Routing Termination Unit (DEOL)
020-877 Extinguishing Interface Module M221-SI
020-643 ID²net Fibre Optic Interface Kit
020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel
Notes:
1. Products are available in language variant as follows:
Group 0: English with English manuals
Mach 2.8
2. Fixed build products incorporate a corresponding Basic Equipment Kit.
Fixed build 8 loop analogue addressable
control and indicating equipment
020-907 8 Loop, PSU7A, Group, 78Ah Battery Enclosure
154g/01
Incorporating the following as modular units:
Enclosures:
020-472-009
020-473-009
020-474-009
020-475-009
20 Oct 2014
Backbox Kit Standard
Backbox Kit Extended, Black / Grey
Backbox Kit Extended Deep, Black / Grey
Backbox Kit Double Extended, Black / Grey
27
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
020-476-009
020-480-501
020-481-009
020-508-009
020-509-009
020-576
020-577
020-621
020-621-009
020-541-501
Backbox Kit Double Extended Deep, Black / Grey
Cover Kit Main Moulded, Black / Grey
Cover Kit Extended Moulded, Black / Grey
Backbox Extension Standard Assembly Black / Grey
Backbox Extension Deep Assembly Black / Grey
Main Cover, Stainless Steel
Extension Cover Stainless Steel
Zone Extension Cover, Stainless / Steel
256 Zone Extension Cover, Black / Grey
PSU7A / 78Ah Battery Enclosure
Modules:
020-559-001
Zone Extension Chassis Kit 1-64 Zone C/W Display Module
020-559-002
Zone Extension Chassis Kit 65-128 Zone C/W Display Module
020-612 Double Extended Chassis Kit 256 Zone
020-708-009
Extension Chassis with Printer
020-644-009
Printer Assembly
020-588 Notifier Dual Loop Interface Board, (LIB)
020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB)
020-478 RS232 Interface
020-479 RS485 Interface
020-648 PSU3A
020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)
020-548 PSU7A Status Indication
020-543 Dual Transmission Path / Booster, PSU Interface
020-773 Routing Termination Unit (DEOL)
020-877 Extinguishing Interface Module M221-SI
020-643 ID²net Fibre Optic Interface Kit
020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel
Notes:
1. Products are available in language variant as follows:
Group 0: English with English manuals
2. Fixed build products incorporate a corresponding Basic Equipment Kit.
Carillion (Novar Systems Ltd)
Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United Kingdom
Tel: 0116 246 2000 • Fax: 0116 246 2300
Website: www.gent.co.uk
Certificate No: 042bc to EN 54-2: 1997+A1:2006 and EN 54-4: 1997 + A1:2002 + A2:2006
Certificated Products
CP2-AMC
Two loop analogue addressable control and indicating equipment
(English language)
LPCB Ref.
No.
042bc/04
Incorporating as modular units:
2434-859
Master Controller Board (MCB)
2434-862
Power Supply Unit
2434-762
Display and Key card (DKC)
2434-669
Loop processor card
4374-161
Text Membrane (English)
2434-861
Copper network card
Scope of approval does not include the operation of the network card)
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
28
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
CP4-AMC
One to Four loop analogue addressable control and indicating equipment (English
language)
LPCB Ref.
No.
042bc/07
Incorporating as modular units:
2434-863
Master controller card (M.C.C)
2434-710
Loop card
2434-831
Power supply PCB
2434-854
Backplane PCB
2434-861
Display and Key card (D.K.C)
2434-864
Terminal card
2434-565
Printer Module
4374-157
Text Membrane (English)
2434-674
Copper network card
Note: Scope of approval does not include the operation of the network card)
7.8
7.11
8.3
9.5
10
CP4-72-AMC
Certified with the following options with requirements from EN 54-2:
Output to fire alarm devices
Delays to outputs
Fault signals from points
Disablement of each address point
Test condition
One to Six loop analogue addressable control and indicating equipment (English
Language)
042bc/11
Incorporating as modular units:
2434-863
Master controller card (M.C.C)
2434-710
Loop card
2434-992
Thermistor board
2434-860
Battery terminal board
2434-832
Power supply PCB
2434-854
Backplane PCB
2434-761
Display and Key card (D.K.C)
2434-864
Terminal card
2434-565
Printer module
4374-157
Text Membrane (English)
2434-674
Copper network card
( Note: Scope of approval does not include the operation of the network card)
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Channel Safety Systems Ltd
9 Petersfield Business Park, Petersfield GU32 3QA, United Kingdom
Tel: 08458847000 • Fax: 08458846000
E-mail: [email protected] • Website: www.chanelsafety.co.uk
Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
CFP702-4/CHAN
Two zone conventional control and indicating equipment
LPCB Ref.
No.
176b/07
Incorporating the units:
RPF0702005 Power supply PCB
SPF0724851 2 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
20 Oct 2014
29
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
CFP704-4/CHAN
LPCB Ref.
No.
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
10 Test condition
Four zone conventional control and indicating equipment
176b/08
Incorporating the units:
RPF0702005 Power supply PCB
SPF0724853 4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
CFP708-4/CHAN
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
10 Test condition
Eight zone conventional control and indicating equipment
176b/09
Incorporating the units:
RPF0702005 Power supply PCB
SPF0724855 8 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
10 Test condition
Computionics Limited (Trading as C-Tec)
Challenge Way, Martland Park, Wigan, Lancashire WN5 OLD, United Kingdom
Tel: +44 (0)1942 322744/42444 • Fax: +44 (0)1942 829867
E-mail: [email protected] • Website: www.c-tec.co.uk
Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
XFP502/H
XFP502/X
2 loop, 32 zone analogue addressable control and indicating equipment using Hochiki
Protocol, metal housing
Incorporating the following units:
SPF0501000 Switch mode power supply board
SPF0501202 XFP Hochiki 2 loop, main motherboard
SPF0501200 Display board "keypad display"
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm device(s)
7.11
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.12.2
Dependencies on more than one alarm signal - Type B
7.12.3
Dependencies on more than one alarm signal - Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality .
2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo
Protocol, metal housing
Incorporating the following units:
SPF0501000 Switch mode power supply board
SPF0501201 XFP Apollo 2 loop, main motherboard
SPF0501200 Display board "Keypad display"
LPCB Ref.
No.
176b/01
176b/02
Certified with the following options with requirements from EN54-2: 1997
30
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.8
7.11
XFP501/H
XFP501/X
XFP501E/H
XFP501E/X
20 Oct 2014
Output to fire alarm device(s)
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
Dependencies on more than one alarm signal - Type A
Dependencies on more than one alarm signal - Type B
Dependencies on more than one alarm signal - Type C
Alarm counter
Fault signals from points
Disablement of each address point
Test condition
7.12.1
7.12.2
7.12.3
7.13
8.3
9.5
10
Notes:
1. Scope of approval does not include the operation of the network functionality.
1 Loop, 32 zone analogue addressable control and indicating equipment using Hochiki
Protocol, metal housing
Incorporating the following units:
SPF0501000 Switch mode power supply board
SPF0501212 XFP Hochiki 1 loop, main motherboard
SPF0501200 Display board "Keypad display"
Certified with the following options with requirements from EN54-2: 1997
7.8
Output to fire alarm device(s)
7.11
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.12.2
Dependencies on more than one alarm signal - Type B
7.12.3
Dependencies on more than one alarm signal - Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality.
1 Loop, 32 zone analogue addressable control and indicating equipment using Apollo
Protocol, metal housing
Incorporating the following units:
SPF0501000 Switch mode power supply board
SPF0501211 XFP Apollo 1 loop, main motherboard
SPF0501200 Display board "keypad display"
Certified with the following options with requirements from EN54-2: 1997
7.8
Output to fire alarm device(s)
7.11
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.12.2
Dependencies on more than one alarm signal - Type B
7.12.3
Dependencies on more than one alarm signal - Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality.
1 Loop, 16 zone analogue addressable control and indicating equipment using Hochiki
protocol, plastic housing
Incorporating the following units:
SPF0702480 Switch mode power supply board
SPF0501102 XFP Hochiki 1 loop, main motherboard
Certified with the following options with requirements from EN54-2: 1997
7.8
Output to fire alarm device(s)
7.11
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.12.2
Dependencies on more than one alarm signal - Type B
7.12.3
Dependencies on more than one alarm signal - Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality
1 Loop, 16 zone analogue addressable control and indicating equipment using Apollo
176b/03
176b/04
176b/05
176b/06
31
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Protocol, plastic housing
Incorporating the following units:
SPF0702480 Switch mode power supply board
SPF0501101 XFP Apollo 1 loop, main motherboard
CFP702-4
Certified with the following options with requirements from EN54-2: 1997
7.8
Output to fire alarm device(s)
7.11
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.12.2
Dependencies on more than one alarm signal - Type B
7.12.3
Dependencies on more than one alarm signal - Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality
Two zone conventional control and indicating equipment
176b/07
Incorporating the units:
SPF0702480
SPF0724851
CFP704-4
Switch mode power supply unit board
2 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices(s)
7.11
Delays to outputs
10
Test condition
Four zone conventional control and indicating equipment
176b/08
Incorporating the units:
SPF0702480
SPF0724853
CFP708-4
Switch mode power supply unit board
4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices(s)
7.11
Delays to outputs
10
Test condition
Eight zone conventional control and indicating equipment
176b/09
Incorporating the units:
SPF0702480
SPF0724855
CFP702-4/ACNL
Switch mode power supply unit board
8 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices(s)
7.11
Delays to outputs
10
Test condition
Two zone conventional control and indicating equipment
176b/10
Incorporating the following units:
SPF0702480
SPF0724837
CFP704-4/ACNL
Switch mode power supply unit board
2 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices(s)
7.11
Delays to outputs
7.13
Alarm counter
10
Test condition
Four zone conventional control and indicating equipment
176b/11
Incorporating the following units:
SPF0702480
SPF0724839
Switch mode power supply unit board
4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices(s)
32
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
CFP708-4/ACNL
LPCB Ref.
No.
7.11
Delays to outputs
7.13
Alarm counter
10
Test condition
Eight zone conventional control and indicating equipment
176b/12
Incorporating the following units:
SPF0702480
SPF0724841
Switch mode power supply unit board
8 Zone main control board
CFP702-2
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices(s)
7.11
Delays to outputs
7.13
Alarm counter
10
Test condition
Alarmsense two zone conventional control and indication equipment
176b/14
CFP704-2
Incorporating the following units:
SPF0702480 Switch mode power supply unit board
SPF0724851 2 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
10 Test condition
Alarmsense four zone conventional control and indicating equipment
176b/15
CFP708-2
Incorporating the following units:
SPF0702480 Switch mode power supply unit board
SPF0724853 4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
10 Test condition
Alarmsense eight zone conventional control and indicating equipment
176b/16
CFP702E-4
CFP704E-4
CFP708E-4
Incorporating the following units:
SPF0702480 Switch mode power supply unit board
SPF0724855 8 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
10 Test condition
Two zone conventional control and indicating equipment
Incorporating the units:
SPF0702480 Switch mode power supply unit board
SPF0724851 2 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
Four zone conventional control and indicating equipment
Incorporating the units:
SPF0702480 Switch mode power supply unit board
SPF0724853 4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
Eight zone conventional control and indicating equipment
Incorporating the units:
SPF0702480 Switch mode power supply unit board
SPF0724855 8 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
176b/17
176b/18
176b/19
Certificate No: 176c to EN 12094-1: 2003 and EN 54-2: 1997 + A1: 2006 + A2: 2007, EN 54-4: 1997 + A1: 2002 + A2: 2006
20 Oct 2014
33
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
EP203
Conventional three zone class A extinguisher control panel
LPCB Ref.
No.
176c/01
Incorporating the following units:
SPF0000203
SPF0000212
SPF0003613
SPF0000214
Main extinguisher control
External relay interface
Power supply unit
EP214 terminator
Incorporating as modular units:
EP210S
EP211
Remote Status Unit Surface Mount optional (See Note 1)
Economy Status Unit optional (See Note 1)
Certified with the following options with requirements from EN 12094-1:2003
4.17
Delay of extinguishing signal
4.18
Signal representing the flow of extinguishing agent
4.19
Monitoring of the status of components
4.20
Emergency hold device
4.21
Control of flooding time
4.23
Manual only mode
4.26
Triggering of equipment outside the system
4.27
Emergency abort device
4.30
Activation of alarm devices with different signals
Certified with the following options with requirements from EN-54-2:1997
7.8
Output to fire alarm device(s)
7.11
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
7.13
Alarm counter
10
Test condition
Notes:
1. Optional Remote Status Unit part No. EP210S & Economy Status Unit part No.
EP211 are not certified as meeting the requirements of the standards specified.
2.
EP203/CON
Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature
range of -5°C to +40°C.
Conventional three zone class A extinguisher control panel under Context Plus Brand
176c/01
Incorporating the following units:
SPF0000203
SPF0000212
SPF0003613
SPF0000214
Main extinguisher control
External relay interface
Power supply unit
EP214 terminator
Incorporating as modular units:
EP210S
EP211
Remote Status Unit Surface Mount optional (See Note 1)
Economy Status Unit optional (See Note 1)
Certified with the following options with requirements from EN 12094-1:2003
4.17
Delay of extinguishing signal
4.18
Signal representing the flow of extinguishing agent
4.19
Monitoring of the status of components
4.20
Emergency hold device
4.21
Control of flooding time
4.23
Manual only mode
4.26
Triggering of equipment outside the system
4.27
Emergency abort device
4.30
Activation of alarm devices with different signals
Certified with the following options with requirements from EN-54-2:1997
7.8
Output to fire alarm device(s)
7.11
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
7.13
Alarm counter
10
Test condition
Notes:
1. Optional Remote Status Unit part No. EP210S & Economy Status Unit part No.
EP211 are not certified as meeting the requirements of the standards specified.
2. Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature
34
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
EP203/DE
LPCB Ref.
No.
range of -5°C to +40°C.
Conventional three zone class A extinguisher control panel German Language Variant
176c/01
Incorporating the following units:
SPF0000203
SPF0000212
SPF0003613
SPF0000214
Main extinguisher control
External relay interface
Power supply unit
EP214 terminator
Incorporating as modular units:
EP210S
EP211
Remote Status Unit Surface Mount optional (See Note 1)
Economy Status Unit optional (See Note 1)
Certified with the following options with requirements from EN 12094-1:2003
4.17
Delay of extinguishing signal
4.18
Signal representing the flow of extinguishing agent
4.19
Monitoring of the status of components
4.20
Emergency hold device
4.21
Control of flooding time
4.23
Manual only mode
4.26
Triggering of equipment outside the system
4.27
Emergency abort device
4.30
Activation of alarm devices with different signals
Certified with the following options with requirements from EN-54-2:1997
7.8
Output to fire alarm device(s)
7.11
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
7.13
Alarm counter
10
Test condition
Notes:
1.
Optional Remote Status Unit part No. EP210S & Economy Status Unit part No.
EP211 are not certified as meeting the requirements of the standards specified.
2.
Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature
range of -5°C to +40°C.
Context Plus Ltd
Export House, 175 Mauldeth Road, Fallowfield, Manchester M14 6SG, United Kingdom
Tel: +44 (0)161 257 2541 • Fax: +44 (0)161 225 8817
E-mail: [email protected] • Website: www.xportsales.com
Certificate No: 176b-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1 :2002 + A2:2006
Certificate No: 176c-(cl-2) to EN 54-2: 1997 + A1: 2006
Control and indicating equipment
Certificated Products
XFP502/X/CON
Two Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo
Protocol, Metal housing
LPCB Ref.
No.
176b/02
Incorporating the following units:
SPF0501000
SPF0501201
SPF0501200
Switch mode power supply board
XFP Apollo 2 Loop, Main motherboard
Display board Keypad Display
Certified with the following options with requirements from EN 54-2:1997
7.8
7.11
7.12.1
20 Oct 2014
Output to fire alarm device(s)
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
Dependencies on more than one alarm signal - Type A
35
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
XFP501/X/CON
LPCB Ref.
No.
7.12.2
Dependencies on more than one alarm signal - Type B
7.12.3
Dependencies on more than one alarm signal - Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Note :
1. Scope of approval does not include the operation of the network functionality.
One Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo
Protocol, Metal housing
176b/04
Incorporating the following units:
SPF0501000
SPF0501211
SPF0501200
Switch mode power supply board
XFP Apollo 1 Loop, Main motherboard
Display board Keypad Display
Certified with the following options with requirements from EN 54-2:1997
7.8
7.11
XFP501E/X/CON
Output to fire alarm device(s)
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
Dependencies on more than one alarm signal - Type A
Dependencies on more than one alarm signal - Type B
Dependencies on more than one alarm signal - Type C
Alarm counter
Fault signals from points
Disablement of each address point
Test condition
7.12.1
7.12.2
7.12.3
7.13
8.3
9.5
10
Note:
1. Scope of approval does not include the operation of the network functionality.
One Loop, 16 Zone Analogue addressable control and indicating
equipment using Apollo protocol, Plastic housing
176b/06
Incorporating the following units:
SPF0702480
SPF0501101
Switch mode power supply board
XFP Apollo 1 Loop, Main motherboard
Certified with the following options with requirements from EN 54-2:1997
7.8
7.11
CFP702-4/CON
Output to fire alarm device(s)
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
Dependencies on more than one alarm signal - Type A
Dependencies on more than one alarm signal - Type B
Dependencies on more than one alarm signal - Type C
Alarm counter
Fault signals from points
Disablement of each address point
Test condition
7.12.1
7.12.2
7.12.3
7.13
8.3
9.5
10
Note:
1. Scope of approval does not include the operation of the network functionality.
Two zone conventional control and indicating equipment
176b/07
Incorporating the units:
SPF0702480
Switch mode power supply unit board
SPF0724851
2 Zone main control board
CFP704-4/CON
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices(s)
7.11
Delays to outputs
10
Test condition
Four zone conventional control and indicating equipment
176b/08
Incorporating the units:
SPF0702480
Switch mode power supply unit board
SPF0724853
4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices(s)
7.11
Delays to outputs
36
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
CFP708-4/CON
LPCB Ref.
No.
10
Test condition
Eight zone conventional control and indicating equipment
176b/09
Incorporating the units:
SPF0702480
SPF0724855
Switch mode power supply unit board
8 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
EP203/CON
7.8
Output to fire alarm devices(s)
7.11
Delays to outputs
10
Test condition
Conventional three zone class A extinguisher control panel under
Context Plus Brand
176c/01
Incorporating the following units:
SPF0000203
SPF0000212
SPF0003613
SPF0000214
Main extinguisher control
External relay interface
Power supply unit
EP214 terminator
Incorporating as modular units:
EP210S
EP211
Remote Status Unit Surface Mount optional (See Note 1)
Economy Status Unit optional (See Note 1)
Certified with the following options with requirements from EN 12094-1:2003
4.17
4.18
4.19
4.20
4.21
4.23
4.26
4.27
4.30
Delay of extinguishing signal
Signal representing the flow of extinguishing agent
Monitoring of the status of components
Emergency hold device
Control of flooding time
Manual only mode
Triggering of equipment outside the system
Emergency abort device
Activation of alarm devices with different signals
Certified with the following options with requirements from EN 54-2:1997
7.8
7.11
Output to fire alarm device(s)
Delays to the auctioning of outputs fire alarm devices
and fire routing equipment
Alarm counter
Test condition
7.13
10
Note:
1. Optional Remote Status Unit part No. EP210S & Economy Status Unit part No. EP211
are not certified meeting the requirements of the standards specified
2. Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature
range of -5°C to +40°C.
Control Equipment Limited
Hillcrest Business Park, Dudley, West Midlands DY2 9AP, United Kingdom
Tel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972
E-mail: [email protected] • Website: www.controlequipment.com
Certificate No: 018c to EN 54: Part 2 and 4: 1997
Certificate No: 681af-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 681ag-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
20 Oct 2014
37
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Control and indicating equipment
Certificated Products
Discovery
Precept En2 (2605-100)
Precept En4 (2605-101)
Precept En8 (2605-102)
Precept En16 (2605-103)
Precept En32 (2605-104)
38
4 loop analogue addressable control and indicating equipment
Incorporating:
A1579 Motherboard
A1580 Display board
A1585 Loop cards
A1584 230 Vac power supply control card
A1599 Printer board
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
2 zone conventional control and indicating equipment
Incorporating as modular units:C1627 Mother board
C1628 Display board
C1631 Repeater interface board (option)
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
4 zone conventional control and indicating equipment
Incorporating as modular units:C1627 Mother board
C1628 Display board
C1631 Repeater interface board (option)
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
8 zone conventional control and indicating equipment
Incorporating as modular units:C1627 Mother board
C1628 Display board
C1631 Repeater interface board (option)
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
16 zone conventional control and indicating equipment
Incorporating as modular units:C1627 Mother board
C1628 Display board
C1631 Repeater interface board (option)
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
32 zone conventional control and indicating equipment
Incorporating as modular units:C1627 Mother board
C1629 Display board
C1631 Repeater interface board (option)
C1632 16 Zone Expansion board
C1652 5A Power supply board
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
LPCB Ref.
No.
018c/01
018c/02
018c/03
018c/04
018c/05
018c/06
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
Precept En8 (2605-110)
Precept En16 Repeater
(2605-111)
Precept En32 Repeater
(2605-112)
508.031.701
LPCB Ref.
No.
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
8 zone conventional repeater unit
Incorporating as modular units:C1627 Mother board
C1628 Display board
C1631 Repeater interface board (option)
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
16 zone conventional repeater unit
Incorporating as modular units:C1627 Mother board
C1628 Display board
C1631 Repeater interface board (option)
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
32 zone conventional repeater unit
Incorporating as modular units:C1627 Mother board
C1628 Display board
C1631 Repeater interface board (option)
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
FIRE CLASS Duo-CEL, 1 zone conventional control and indicating equipment
018c/R01
018c/R02
018c/R03
681af/01
Incorporating as modular units:
C1694 - 2605501, 1 Zone Motherboard
BAQ-35T24 Power Supply
508.031.702
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.13
Alarm counter
10
Test condition
FIRE CLASS Duo-CEL, 2 zone conventional control and indicating equipment
681af/02
Incorporating as modular units:
C1694 - 2605502, 2 Zone Motherboard
BAQ-35T24 Power Supply
508.031.703
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.13
Alarm counter
10
Test condition
FIRE CLASS Duo-CEL, 4 zone conventional control and indicating equipment
681af/03
Incorporating as modular units:
C1694 - 2605503 4 Zone Motherboard
BAQ-35T24 Power Supply
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.12.1
Dependencies on more than one alarm signal - Type A
20 Oct 2014
39
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
508.031.704
LPCB Ref.
No.
7.13
Alarm counter
10
Test condition
FIRE CLASS Duo-CEL, 8 zone conventional control and indicating equipment
681af/04
Incorporating as modular units:
C1694 - 2605504, 8 Zone Motherboard
BAQ-35T24 Power Supply
508.031.705
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.13
Alarm counter
10
Test condition
FIRE CLASS Duo-CEL, Fire alarm repeater (mains).
681af/R01
508.031.706
Incorporating as modular units:
C1694 2605505, Repeater Motherboard
BAQ-35T24 Power Supply
Note: Compatible with 2605543 & 2605544 panels only.
FIRE CLASS Duo-CEL, Fire alarm repeater (24 VDC).
681af/R02
Incorporating as a modular unit:
C1694 2605506, Repeater Motherboard
Note: Compatible with 2605543 & 2605544 panels only.
FC32-1
FIRECLASS 557.200.701 analogue addressable control and indicating equipment
1 loop, 32 Zone
Incorporating as modular units:
DCM832R
Operator Control / Display Module
CPU800
Main CPU module
FIM801
Field Interface Module
PMM800
Power Supply Monitor
BAQ60T24
Power Supply
681ag/01
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Note:
1) This product approval does not constitute compliance with
the fire detection and alarm systems requirements of EN 54-13.
FC64-2
FIRECLASS (557.200.702) analogue addressable control and indicating equipment 2
loop, 64 Zone
Incorporating as modular units:
DCM864R
Operator Control / Display Module
CPU800 Main CPU module
FIM802
Field Interface Module
PMM800
Power Supply Monitor
BAQ140T24
Power Supply
681ag/02
and as optional modular units:
IOB800
Input/Output Expansion Board
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
40
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
FC64-4
FC240-2
20 Oct 2014
LPCB Ref.
No.
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Note:
1. This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
FIRECLASS (557.200.703) analogue addressable control and indicating equipment
4 loop, 64 Zone
Incorporating as modular units:
DCM864R
Operator Control / Display Module
CPU800 Main CPU module
FIM802
Field Interface Module
PMM800
Power Supply Monitor
BAQ140T24
Power Supply
PMM840
Power Supply Monitor
XLM800
Loop Expander Board
and as optional modular units:
IOB800
Input/Output Expansion Board
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Note:
This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
FIRECLASS (557.200.704) analogue addressable control and indicating equipment
2 loop, 240 Zone
Incorporating as modular units:
DCM832
Operator Control / Display Module
CPU800 Main CPU module
FIM802
Field Interface Module
PMM800
Power Supply Monitor
BAQ140T24
Power Supply
and as optional modular units:
IOB800
Input/Output Expansion Board
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
681ag/03
681ag/04
41
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.12.1
7.12.2
7.12.3
7.13
8.3
8.9
9.5
10
11
Note:
Dependencies on more than one alarm signal (Type A dependency)
Dependencies on more than one alarm signal (Type B dependency)
Dependencies on more than one alarm signal (Type C dependency)
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Standardized input/output interface
1)
FC240-4
557.200.706
This product approval does not constitute
compliance with
the fire detection and alarm systems requirements
of EN 54-13.
FIRECLASS (557.200.705) analogue addressable control and indicating equipment
4 loop, 240 Zone
Incorporating as modular units:
DCM832 Operator Control / Display Module
CPU800 Main CPU module
FIM802
Field Interface Module
PMM800
Power Supply Monitor
BAQ140T24
Power Supply
PMM840
Power Supply Monitor
XLM800
Loop Expander Board
and as optional modular units:
IOB800
Input/Output Expansion Board
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Note:
This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
FIRE CLASS 32 RA, 32 Zone Repeater Panel, is approved for use with the 557.200.701
Fire Class 32-1 control and indicating equipment.
Incorporating as modular units:
681ag/05
681ag/R01
557.200.707
DCM832R
Operator Control / Display Module
PMM800
Power Supply Monitor
BAQ60T24
Power Supply
FIRE CLASS 64 RA, 64 Zone Repeater Panel, is approved for use with the 557.200.702
Fire Class 64-2 and 557.200.703 Fire Class 64-4
control and indicating equipment.
Incorporating as modular units:
681ag/R02
557.200.708
DCM864R
Operator Control / Display Module
PMM800
Power Supply Monitor
BAQ60T24
Power Supply
FIRE CLASS 240 RA, 240 Zone Repeater Panel, is approved
for use with the 557.200.704 Fire Class 240-2
and 557.200.705 Fire Class 240-4 control and indicating equipment.
Incorporating as modular units:
681ag/R03
DCM832
PMM800
BAQ60T24
42
Operator Control / Display Module
Power Supply Monitor
Power Supply
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificate No: 681ad-(cl-1) to EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 681ac-(cl-1) to EN 54-4: 1997 + A1: 2002 + A2: 2006
Power Supply Unit
Certificated Products
PSU A17
PSU A38
557.200.732
557.200.733
557.200.731
Addressable 17Ah Power Supply Unit
Notes:
1. The unit is not intended to supply power to Fire Alarm Control Panels
2. The maximum lead length for the fault output connection is 3m
Addressable 38Ah Power Supply Unit
Notes:
1. The unit is not intended to supply power to Fire Alarm Control Panels
2. The maximum lead length for the fault output connection is 3m
PSU A17 Addressable 17Ah Power Supply Unit
Notes:
1. The unit is not intended to supply power to Fire Alarm Control Panels
2. The maximum lead length for the fault output connection is 3m
PSU A38 Addressable 38Ah Power Supply Unit
Notes:
1. The unit is not intended to supply power to Fire Alarm Control Panels
2. The maximum lead length for the fault output connection is 3m
FIRE CLASS 1.9A Power Supply Unit
Notes:
1. The unit is not intended to supply power to Fire Alarm Control Panels
LPCB Ref.
No.
681ac/01
681ac/02
681ad/01
681ad/02
681ad/03
Certificate No: 018a to BS 5839: Part 4. This certificate is to a withdrawn standard. Control and indicating equipment conforming
to this standard is not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn
standard, is maintained because control and indicating equipment meeting the withdrawn standard is still requested by some
regulators outside of the EU.
Control and indicating equipment
Certificated Products
Precept
Precept
Precept
Precept
20 Oct 2014
2 zone control and indicating equipment
Incorporating as modular units
C1423 Motherboard
C1440 Display Board
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
4 zone control and indicating equipment
Incorporating as modular units
C1423 Motherboard
C1441 Display Board
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
8 zone control and indicating equipment
Incorporating as modular units
C1427 Motherboard
C1462 Display Board
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
16 zone control and indicating equipment
Incorporating as modular units
C1425 Motherboard
C1426 Display Board
LPCB Ref.
No.
018a/01
018a/02
018a/03
018a/04
43
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
Precept
Series 600
Series 600
Series 600
Series 600
Series 600
44
LPCB Ref.
No.
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
32 zone control and indicating equipment
Incorporating as modular units
C1425 Motherboard
C1426 Display Board
C1464 Display Board
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
2 zone control and indicating equipment
Incorporating as modular units
C1423 Motherboard
C1440 Display Board
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
4 zone control and indicating equipment
Incorporating as modular units
C1423 Motherboard
C1441 Display Board
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
8 zone control and indicating equipment
Incorporating as modular units
C1427 Motherboard
C1462 Display Board
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
16 zone control and indicating equipment
Incorporating as modular units
C1425 Motherboard
C1426 Display Board
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
32 zone control and indicating equipment
Incorporating as modular units
C1425 Motherboard
C1426 Display Board
C1464 Display Board
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
018a/05
018a/06
018a/07
018a/08
018a/09
018a/10
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Cooper Industries Inc
Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom
Tel: +44 (0)1302 303303 • Fax: +44 (0)1302 367155
E-mail: [email protected] • Website: www.cooper-ls.com
UK Sales:
Menvier & JSB
Tel: +44 (0)1302 303202 • Fax: +44 (0)1302 367155
E-mail: [email protected] • Website: www.cooper-ls.com
UK Sales:
Tel: +44 (0)1594 541900 • Fax: +44 (0)1594 541910
E-mail: [email protected] • Website: www.cooperfire.co.uk
Certificate No: 714a to EN 54 Part 2 and 4 :1997
Certificated Products
CF3000
DF6000
20 Oct 2014
Analogue addressable 2 and 4 loop Control and indicating equipment
Incorporating the following units:
ADF6 Assembled back box
YPCB2153 Motherboard PCB
YPCB2147 PSU PCB
YPCB2148 2 Loop card (2 off)
ADF6 Screen Touch Screen
YPCB2185 Complete Display + Micro PCB
ADF6DISPCOVER Display PCB Cover
ADF6FACIA Front Moulding
ADF6PRINTDOOR Printer Door Moulding
BAT-NP12-12 Batteries (2 off)
ADF6HINGE Door Hinges
ADF6OPFACIA Optional Anti Tamper Cover
ADF6PRINTER Printer
YPCB2187 Fire Brigade Interface
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm device(s)
7.9
Output to fire alarm routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
7.12
Coincidence detection
7.13
Alarm counter
8.9
Output to fault warning routing equipment
9.5
Disablement of each address point
10
Test condition
Analogue addressable 2 and 4 loop control and indicating equipment
Incorporating the following units:
ADF6 Assembled back box
YPCB2153 Motherboard PCB
YPCB2147 PSU PCB
YPCB2148 2 Loop card (2 off)
ADF6Screen Touch Screen
YPCB2185 Complete Display + Micro PCB
ADF6DISPCOVER Display PCB Cover
ADF6FACIA Front Moulding
ADF6PRINTDOOR Printer Door Moulding
BAT-NP12-12 Batteries (2 off)
ADF6HINGE Door Hinges
ADF6OPFACIA Optional Anti Tamper Cover
ADF6PRINTER Printer
YPCB2187 Fire Brigade Interface
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm device(s)
7.9
Output to fire alarm routing equipment
LPCB Ref.
No.
714a/01
714a/01
45
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.10
7.11
FX6000
CF2000
Output to automatic fire protection equipment
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
7.12
Coincidence detection
7.13
Alarm counter
8.9
Output to fault warning routing equipment
9.5
Disablement of each address point
10
Test condition
Analogue addressable 2 and 4 Loop control and indicating equipment
Incorporating the following units:
ADF6 Back Assembled back box
YPCB2153 Motherboard PCB
YPCB2147 PSU PCB
YPCB2148 2 Loop Card (2 off)
ADF6Screen Touch Screen
YPCB2185 Complete Display + Micro PCB
ADF6 DISPCOVER Display PCB Cover
ADF6FACIA Front Moulding
ADF6PRINTDOOR Printer Door Moulding
BAT-NP12-12 Batteries (2 off)
ADF6HINGE Door Hinges
ADF6OPFACIA Optional Anti Tamper Cover
ADF6PRINTER Printer
YPCB2187 Fire Brigade Interface
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm device(s)
7.9
Output to fire alarm routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
7.12
Coincidence detection
7.13
Alarm counter
8.9
Output to fault warning routing equipment
9.5
Disablement of each address point
10
Test condition
Analogue addressable 2 Loop control and indicating equipment
Incorporating the following units:
PR202-50-2209 Power supply board
PR202-50-2206 Main motherboard
PR202-50-2205 Display board
Certified with the following options from EN 54 Part 2:
7.8
Output to fire alarm device(s)
7.9
Output to fire alarm routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to the actioning of outputs fire alarm devices and fire routing
equipment
7.12
Coincidence detection
7.13
Alarm counter
8.9
Output to fault warning routing equipment
9.5
Disablement of each address point
10
Test condition
714a/01
714a/02
Cooper Lighting and Safety Ltd
Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom
Tel: +44 (0)1302 303397 • Fax: +44 (0)1302 303251
Website: www.cooper-Is.com
Certificate No: 714h to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 714p to EN 54-2:1197+ A1:2006 and EN 54-4:1997+A1:2002+A2:2006
Certificate No: 714n to EN 54-16:2008
Certificated Products
CF3000
Intelligent analogue addressable 2 and 4 loop control and indicating equipment
LPCB Ref.
No.
714h/01
Incorporating the following units:
46
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
ADF6 Back
YPCB2153
YPCB2147
YPCB2148
ADF6Screen
YPCB2185
ADF6 DISPCOVER
ADF6FACIA
ADF6PRINTDOOR
BAT-NP12-12
ADF6HINGE
ADF6OPFACIA
ADF6PRINTER
YPCB2187
Assembled back box
Motherboard PCB
PSU PCB
2 Loop Card (2 off)
Touch Screen
Complete Display + Micro PCB
Display PCB Cover
Front Moulding
Printer Door Moulding
Batteries (2 off)
Door Hinges
Optional Anti Tamper Cover
Printer
Fire Brigade Interface
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment
7.10.1
Output to automatic fire protection equipment (Type A)
7.10.2
Output to automatic fire protection equipment (Type B)
7.11
Delays to outputs
7.12.3
Dependencies on more than one alarm signal (Type C)
7.13
Alarm counter
8.9
Output to fault warning routing equipment
9.5
Disablement of each address point
10
Test condition
Notes:
1.
2.
DF6000
The scope of approval does not include the network functionality.
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Intelligent analogue addressable 2 and 4 loop control and indicating equipment
714h/01
Incorporating the following units:
ADF6 Back
YPCB2153
YPCB2147
YPCB2148
ADF6Screen
YPCB2185
ADF6 DISPCOVER
ADF6FACIA
ADF6PRINTDOOR
BAT-NP12-12
ADF6HINGE
ADF6OPFACIA
ADF6PRINTER
YPCB2187
Assembled back box
Motherboard PCB
PSU PCB
2 Loop Card (2 off)
Touch Screen
Complete Display + Micro PCB
Display PCB Cover
Front Moulding
Printer Door Moulding
Batteries (2 off)
Door Hinges
Optional Anti Tamper Cover
Printer
Fire Brigade Interface
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment
7.10.1
Output to automatic fire protection equipment (Type A)
7.10.2
Output to automatic fire protection equipment (Type B)
7.11
Delays to outputs
7.12.3
Dependencies on more than one alarm signal (Type C)
7.13
Alarm counter
8.9
Output to fault warning routing equipment
9.5
Disablement of each address point
10
Test condition
Notes:
1.
2.
CF2000
20 Oct 2014
The scope of approval does not include the network functionality.
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Analogue addressable 2 loop control and indicating equipment
714h/02
47
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating the following units:
PR202-50-2209 Power supply board
PR202-50-2206 Main motherboard
PR202-50-2205 Display board
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment
7.10.1
Output to automatic fire protection equipment (Type A)
7.11
Delays to outputs
7.12.3
Dependencies on more than one alarm signal (Type C)
7.13
Alarm counter
8.9
Output to fault warning routing equipment
9.5
Disablement of each address point
10
Test condition
Notes:
1.
2.
VoCall
The scope of approval does not include the network functionality.
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
CFVADAU100 100W Single channel addressable DAU with EMA Emergency
microphone
714n/01
VoCALL DAU Unit consisting of:
VoCALL Voice DAU Controller rev 2 (YPCB2387)
VoCALL Voice DAU Base Board rev 4 (YPCB2386)
Audio Safe Module rev 3 (YPCB2353)
DF6000 PSU (YPCB2147CPD)
Cooper PAVA Loop to Voice rev 1(YPCB2345)
VoCALL Voice DAU 100V line connector rev0 (YPCB2389)
VoCALL Voice LSA 50/100 Amplifier (YPCB2388)
VoCALL EMA Emergency microphone unit consisting of:
VoCALL Voice FMA rev 1
VoCALL Voice FMA Display rev 0 (YPCB2390)
Certified with the following options with requirements from EN 54-16
7.6.2
Manual silencing of the voice alarm condition
7.7.2
Manual rest of the voice alarm condition
8.3
Indication of faults related to the transmission path to the CIE
12.0
Emergency microphone(s) (applicable on EMA unit only
CF5002
Two zone conventional control and indicating equipment
714p/01
Incorporating the units:
PA-04-0244 Main control board with integrated power supply
PA-04-0248 2 Zone display board
CF5004
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
10 Test condition
Four zone conventional control and indicating equipment
714p/02
Incorporating the units:
PA-04-0245 Main control board with integrated power supply
PA-04-0249 4 Zone display board
CF5008
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
10 Test condition
Eight zone conventional control and indicating equipment
714p/03
Incorporating the units:
PA-04-0246
Main control board with integrated power supply
PA-04-0250
8 Zone display board
Certified with the following options with requirements from EN 54-2: 1997
48
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
CF50016
LPCB Ref.
No.
7.8 Output to fire alarm devices(s)
10 Test condition
Sixteen zone conventional control and indicating equipment
714p/04
Incorporating the units:
PA-04-0247
Main control board with integrated power supply
PA-04-0251
16 Zone display board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
10 Test condition
Detector Electronics Corporation
6901 West 110th Street, Minneapolis, Minesota 55438, USA
Tel: +001 952 946 6488
E-mail: [email protected] • Website: www.det-tronics.com
Certificate No: 973c to EN 54-2: 1997 + A1: 2006
Certificate No: 973d to EN 54-2: 1997 + A1: 2006 + EN12094-1: 2003
Certificated Products
EQ5400D
Single loop eight zone addressable control and indicating equipment
IQ3150 Controller
Detection panel
EQ2220 (GFM)
LTM
EQ3730 (EDIO)
LPCB Ref.
No.
973c/01
Main controller
Detection panel
Ground Fault Monitor
Lon termination module
Enhanced Discrete Input/Output (SIL only)
and as optional modular units:
EQ3710 (AIM)
EQ3720 (RM)
Model EQ22EM (IDCSC)
Model EQ25EM (SAM)
Model EQ24EM (NE)
Model EQ24EM (PLR)
EQ3810 (PDM)
750XCXH-24D
EQ5400R
Analogue Input Module
Relay Module
Initiating Device Circuit - Short Circuit
Signal Audible Module
Network Extender
Physical Layer Repeater
Power Distribution Module
Magnecraft relay module
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.13
Alarm counter
8.3
Fault signals from points
10
Test condition
Single loop eight zone addressable control and indicating equipment
973c/02
Incorporating as modular units:
EQ3150 Controller
Detection panel
Routing panel
EQ2220 (GFM)
LTM
EQ3730 (EDIO)
Main controller
Detection panel
Routing panel
Ground Fault Monitor
Lon termination module
Enhanced Discrete Input/Output (SIL only)
and as optional modular units:
EQ3710 (AIM)
EQ3720 (RM)
Model EQ22EM (IDCSC)
Model EQ25EM (SAM)
20 Oct 2014
Analogue Input Module
Relay Module
Initiating Device Circuit - Short Circuit
Signal Audible Module
49
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Model EQ24EM (NE)
Model EQ24EM (PLR)
EQ3810 (PDM)
750XCXH-24D
EQ5400E
Network Extender
Physical Layer Repeater
Power Distribution Module
Magnecraft relay module
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
10
Test condition
Single loop eight zone addressable control and indicating equipment and two
extinguishing zone class B electrical automatic control and delay devices
973d/01
Incorporating as modular units:
EQ3150 Controller
Detection panel
Routing panel
Extinguishing panel
EQ2220 (GFM)
EQ3LTM
EQ3730 (EDIO)
Main controller (Redundant)
Detection panel
Routing panel
Extinguishing panel
Ground Fault Monitor
Lon termination module
Enhanced Discrete Input/Output (SIL only)
and as optional modular units:
EQ3710 (AIM)
EQ3720 (RM)
Model EQ22EM (IDCSC)
Model EQ25EM (SAM)
Model EQ24EM (NE)
Model EQ24EM (PLR)
EQ3810 (PDM)
750XCXH-24D
Analogue Input Module
Relay Module
Initiating Device Circuit - Short Circuit
Signal Audible Module
Network Extender
Physical Layer Repeater
Power Distribution Module
Magnecraft relay module
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
10
Test condition
EQ5400G
Certified with the following options with requirements from EN 12094-1:
4.17
Delay of extinguishing signal
4.18
Signal representing the flow of extinguishing agent
4.19
Monitoring of the status of components
4.20
Emergency hold device
4.21
Control of flooding time
4.23
Manual only mode
4.24
Triggering signals to equipment within the system
4.26
Triggering of equipment outside the system
Single loop eight zones Addressable control and indicating equipment and two
extinguishing zone class B electrical automatic control and delay devices.
973d/02
Incorporating as modular units:
EQ3150 Controller
Detection panel
Extinguishing panel
EQ2220 (GFM)
50
Main controller (Redundant)
Detection panel
Extinguishing panel
Ground Fault Monitor
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
EQ3LTM
EQ3730 (EDIO)
Lon termination module
Enhanced Discrete Input/Output (SIL only)
and as optional modular units:
EQ3710 (AIM)
EQ3720 (RM)
Model EQ22EM (IDCSC)
Model EQ25EM (SAM)
Model EQ24EM (NE)
Model EQ24EM (PLR)
EQ3810 (PDM)
750XCXH-24D
Analogue Input Module
Relay Module
Initiating Device Circuit - Short Circuit
Signal Audible Module
Network Extender
Physical Layer Repeater
Power Distribution Module
Magnecraft relay module
Certified with the following options with requirements from EN 54 Part 2:
7.8
7.10.1
7.10.2
7.10.3
7.10.4
7.12.2
7.13
8.3
8.4
10
Output to fire alarm devices
Outputs to fire protection equipment (Type A)
Outputs to fire protection equipment (Type B)
Outputs to fire protection equipment (Type C)
Fault monitoring of fire protection equipment
Dependencies on more than one alarm signal (Type B dependency)
Alarm counter
Fault signals from points
Total loss of the power supply
Test condition
Certified with the following options with requirements from EN 12094-1:
4.17
4.18
4.19
4.20
4.21
4.23
4.24
4.26
Delay of extinguishing signal
Signal representing the flow of extinguishing agent
Monitoring of the status of components
Emergency hold device
Control of flooding time
Manual only mode
Triggering signals to equipment within the system
Triggering of equipment outside the system
Emirates Fire Protections Equip. Factory. TR. Section
Behind the Fourth Industrial Estate, Industrial Area 3, UAE PO 22436, Sharjah, United Arab Emirates
Tel: 00971 653 40300 • Fax: 00971 653 40090
E-mail: [email protected] • Website: www.firexuae.com
Certificate No: 548p-(cl-5) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Control and indicating equipment
Certificated Products
FX200-2
Intelligent 2 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment
Incorporating the following units:
MB-220/ F7.820.826
SB-220/ F7.820.827
TB-220/ F7.820.828
PS-220/ F7.820.829b
ZP-220/ F7.820.312d
LC200/ F7.820.1125
LPCB Ref.
No.
548p/01
Main board
Switch board
Loop interface board
Power supply unit
Zone indication and intervention board
Loop board
Incorporating as optional modular units:
FX9930/ F7.820.913a
RS-232 board for configuration
FX9901A
Printer module kit
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
7.10.1
Output to automatic Fire Protection
Equipment Type A
20 Oct 2014
51
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
FX-IFP8
LPCB Ref.
No.
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment
548p/02
Incorporating the following units:
SB-800/ F7.820.1238
Indication board
LCIFP8/ F7.820.1239
Loop board
PB-800/ F7.820.1311
Power board
ZP-800/ F7.820.1312
ZCP board
KB-800/ F7.820.1326
Keypad board
MB-800/ F7.820.1237
Main board
MO-800/ F7.820.1310
Mother board
Incorporating as optional modular units:
P-9935/ F7.820.1313
USB communication board
Optional language variants:
10104673 Portuguese language variant
10104675 Hungarian language variant
Certified with the following options with requirements from EN 54 Part 2:
FX102A
7.8
Output to fire alarm devices
7.9.1
Output to fire routing equipment
7.9.2
Alarm confirmation input from fire routing equipment
7.10.1
Output type A
7.10.2
Output type B
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal - Type A
7.12.2
Dependencies on more than one alarm signal - Type B
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
2 Zone conventional control and indicating equipment
548p/03
Incorporating the following modules:
FC-102A/ F7.843.399
Membrane
CB-102A/ F2.908.1719
Control board with integrated PSE
DB-102A/ F2.908.1722
Display board
FX104A
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire routing equipment
7.11
Delays to outputs
10
Test condition
4 Zone conventional control and indicating equipment
548p/04
Incorporating the following modules:
FC-104A/ F7.843.400
Membrane
CB-104A/ F2.908.1718
Control board with integrated PSE
DB-104A/ F2.908.1721
Display board
Optional modules:
10104649 Traditional Chinese text variant
CF-104A/ F7.843.422
Membrane
FX108A
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire routing equipment
7.11
Delays to outputs
10
Test condition
8 Zone conventional control and indicating equipment
548p/05
Incorporating the following modules:
FC-108A/ F7.843.401
Membrane
CB-108A/ F2.908.1675
Control board with integrated PSE
DB-108A/ F2.908.1720
Display board
Optional modules:
10104650 Traditional Chinese text variant
52
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
CF-108A/ F7.843.423
FX116A
Membrane
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire routing equipment
7.11
Delays to outputs
10
Test condition
16 Zone conventional control and indicating equipment
548p/06
Incorporating the following modules:
FC-116A/ F7.843.402
Membrane
XB-116A/ F2.908.1724
Control board with integrated PSE
DB-116A/ F2.908.1676
Display board
CB-116A/ F7.820.1677
Expansion board
Optional modules:
10104651 Traditional Chinese text variant
CF-116A/ F7.843.424
Membrane
FX200-2/1
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire routing equipment
7.11
Delays to outputs
10
Test condition
Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment
Incorporating the following units:
MB-220/ F7.820.826
SB-220/ F7.820.827
TB-220/ F7.820.828
PS-220/ F7.820.829b
ZP-220/ F7.820.312d
548P/08
Main board
Switch board
Loop interface board
Power supply unit
Zone indication and intervention board
Incorporating as optional modular units:
FX9930/ F7.820.913a
RS-232 board for configuration
FX9901A
Printer module kit
LC200/ F7.820.1125
Loop board (for loop expansion)
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
7.10.1
Output to automatic Fire Protection
Equipment Type A
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
Eurotech Fire Systems Limited
19/20 Stratfield Park, Elettra Avenue, Waterlooville, Hampshire PO7 7XN, United Kingdom
Tel: +44 (0)203 141 0999 • Fax: +44 (0)239 225 2554
E-mail: [email protected] • Website: www.eurotechfire.com
Certificate No: 1213b to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 and EN 54-4: 1998 + A1: 2002 + A2:
Certificate No: 1213a to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 and EN 54-4: 1998 + A1: 2002 + A2: 2006
Control and indicating equipment
Certificated Products
510-0108A Odyssey Plus
One loop, 32 Zone analogue addressable control and indicating equipment.
LPCB Ref.
No.
1213b/01
Incorporating as modular units:
BRD68BPSC4-A FFP Brigade & Power supply control board (8610)
BRD86DLTB4-A FFP Dual loop termination board (8610)
BRD86FPB5-B FFP Front panel board EN54 (8610)
BRD86MBA4-A FFP Main board LCD (8610)
BRD86MCPU4-B FFP Main 64MB CPU card (8610)
20 Oct 2014
53
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
510-0208A Odyssey Plus
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
PSU1888 Power supply 5A (8610)
Optional Modules:
BRD43EZC2-A 8 Zone conventional module (4310)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routine equipment
7.11 Delay to outputs
7.12.1 Dependencies on more than one alarm signal Type A
7.12.2 Dependencies on more than one alarm signal Type B
7.12.3 Dependencies on more than one alarm signal Type C
8.3 Fault signal from points
8.9 Output to fault warning routing equipment
9.5 Disablement of each addressable point
10 Test condition
Two loop, 32 Zone analogue addressable control and indicating equipment.
1213b/02
510-0308A Odyssey Plus
Incorporating as modular units:
BRD68BPSC4-A FFP Brigade & Power supply control board (8610)
BRD86DLTB4-A FFP Dual loop termination board (8610)
BRD86FPB5-B FFP Front panel board EN54 (8610)
BRD86MBA4-A FFP Main board LCD (8610)
BRD86MCPU4-B FFP Main 64MB CPU card (8610)
BRD86SCB3-A FFP Slave CPU card (8610)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
PSU1888 Power supply 5A (8610)
Optional Modules:
BRD43EZC2-A 8 Zone conventional module (4310)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routine equipment
7.11 Delay to outputs
7.12.1 Dependencies on more than one alarm signal - Type A
7.12.2 Dependencies on more than one alarm signal - Type B
7.12.3 Dependencies on more than one alarm signal - Type C
8.3 Fault signal from points
8.9 Output to fault warning routing equipment
9.5 Disablement of each addressable point
10 Test condition
Three loop, 32 Zone analogue addressable control and indicating equipment
1213b/03
Incorporating as modular units:
BRD68BPSC4-A FFP Brigade & Power supply control board (8610)
BRD86DLTB4-A FFP Two Dual loop termination boards (8610)
BRD86FPB5-B FFP Front panel board EN54 (8610)
BRD86MBA4-A FFP Main board LCD (8610)
BRD86MCPU4-B FFP Main 64MB CPU card (8610)
BRD86SCB3-A FFP Two Slave CPU cards (8610)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
PSU1888 Power supply 5A (8610)
Optional Modules:
BRD86DLTB4-A FFP Dual loop termination board (8610)
BRD86SCB3-A FFP Slave CPU cards (8610)
BRD43EZC2-A 8 Zone conventional module (4310)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routine equipment
7.11 Delay to outputs
7.12.1 Dependencies on more than one alarm signal Type A
7.12.2 Dependencies on more than one alarm signal Type B
7.12.3 Dependencies on more than one alarm signal Type C
8.3 Fault signal from points
8.9 Output to fault warning routing equipment
9.5 Disablement of each addressable point
10 Test condition
Incorporating as modular units:
54
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
510-0408A Odyssey Plus
LPCB Ref.
No.
BRD68BPSC4-A FFP Brigade & Power supply control board (8610)
BRD86DLTB4-A FFP Two Dual loop termination boards (8610)
BRD86FPB5-B FFP Front panel board EN54 (8610)
BRD86MBA4-A FFP Main board LCD (8610)
BRD86MCPU4-B FFP Main 64MB CPU card (8610)
BRD86SCB3-A FFP Two Slave CPU cards (8610)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
PSU1888 Power supply 5A (8610)
Optional Modules:
BRD86DLTB4-A FFP Dual loop termination board (8610)
BRD86SCB3-A FFP Slave CPU cards (8610)
BRD43EZC2-A 8 Zone conventional module (4310)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routine equipment
7.11 Delay to outputs
7.12.1 Dependencies on more than one alarm signal Type A
7.12.2 Dependencies on more than one alarm signal Type B
7.12.3 Dependencies on more than one alarm signal Type C
8.3 Fault signal from points
8.9 Output to fault warning routing equipment
9.5 Disablement of each addressable point
10 Test condition
Four loop, 32 Zone analogue addressable control and indicating equipment
1213b/04
Incorporating as modular units:
BRD68BPSC4-A FFP Brigade & Power supply control board (8610)
BRD86DLTB4-A FFP Two Dual loop termination boards (8610)
BRD86FPB5-B FFP Front panel board EN54 (8610)
BRD86MBA4-A FFP Main board LCD (8610)
BRD86MCPU4-B FFP Main 64MB CPU card (8610)
BRD86SCB3-A FFP Three Slave CPU cards (8610)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
PSU1888 Power supply 5A (8610)
Optional Modules:
BRD86DLTB4-A FFP Dual loop termination board (8610)
BRD86SCB3-A FFP Slave CPU cards (8610)
BRD43EZC2-A 8 Zone conventional module (4310)
BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routine equipment
7.11 Delay to outputs
7.12.1 Dependencies on more than one alarm signal Type A
7.12.2 Dependencies on more than one alarm signal Type B
7.12.3 Dependencies on more than one alarm signal Type C
8.3 Fault signal from points
8.9 Output to fault warning routing equipment
9.5 Disablement of each addressable point
10 Test condition
Fike Safety Technology Ltd
Unit 31, Springvale Industrial Estate, Cwmbran, Gwent NP44 5BD, United Kingdom
Tel: +44 (0)1633 865558 • Fax: +44 (0)1633 866656
E-mail: [email protected] • Website: www.fikesafetytechnology.co.uk
Certificate No: 331q to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
507-0001
Quadnet, 4 loop analogue addressable control and indicating equipment
LPCB Ref.
No.
331q/01
Incorporating the following units:
20 Oct 2014
55
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
10-0049
10-0050
SP14Q006-T
10-0051
10-0058
10-0053
Main CIE Board
LED Board
LCD Module
Backplane
Loop Card
PSU Interface
Certified with the following options with requirements from EN54-2:
7.8
7.10.1
7.11
7.12.2
8.3
8.9
9.5
10
Note:
1.
507-0009
Output to fire alarm devices
Output to fire protection equipment - Type A
Delays to outputs
Dependencies on more than one alarm signal - Type B
Fault signals from points
Fault warning routing equipment
Disablement of each addressable point
Test condition
This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13
Quadnet, 4 loop analogue addressable control and indicating equipment with printer
331q/02
Incorporating the following units:
10-0049
Main CIE Board
10-0050
LED Board
SP14Q006-T
LCD Module
10-0051
Backplane
10-0058
Loop Card
10-0053
PSU Interface
21-0005
Printer
Certified with the following options with requirements from EN54-2:
7.8
7.10.1
7.11
7.12.2
8.3
8.9
9.5
10
Note:
1.
510-0001
Output to fire alarm devices
Output to fire protection equipment - Type A
Delays to outputs
Dependencies on more than one alarm signal - Type B
Fault signals from points
Fault warning routing equipment
Disablement of each addressable point
Test condition
This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13
Duonet, 2 loop analogue addressable control and indicating equipment
331q/04
Incorporating the following units:
10-0049
Main CIE Board
10-0050
LED Board
SP14Q006-T
LCD Module
10-0069
Backplane
10-0058
Loop Card
10-0053
PSU Interface
Certified with the following options with requirements from EN54-2:
7.8
7.10.1
7.11
7.12.2
8.3
8.9
9.5
10
Note:
1.
510-0003
56
Output to fire alarm devices
Output to fire protection equipment - Type A
Delays to outputs
Dependencies on more than one alarm signal - Type B
Fault signals from points
Fault warning routing equipment
Disablement of each addressable point
Test condition
This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13
Duonet, 2 loop analogue addressable control and indicating equipment with printer
331q/05
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating the following units:
10-0049 Main CIE Board
10-0050 LED Board
SP14Q006-T
LCD Module
10-0069
Backplane
10-0058
Loop Card
10-0053
PSU Interface
21-0005
Printer
Certified with the following options with requirements from EN54-2:
7.8
7.10.1
7.11
7.12.2
8.3
8.9
9.5
10
Note:
1.
505-0002
Output to fire alarm devices
Output to fire protection equipment - Type A
Delays to outputs
Dependencies on more than one alarm signal - Type B
Fault signals from points
Fault warning routing equipment
Disablement of each addressable point
Test condition
This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13
TWINFLEXpro, 2 Zone conventional control and indicating equipment
331q/06
Incorporating:
10-0067 Main Processor Card.
Certified with the following options from EN 54 Part 2:
505-0004
7.8
Output to fire alarm devices
7.10.1
Output type A to fire protection equipment
7.11
Delays to outputs
7.12.1
Type A dependency on more than one alarm signal
8.3
Fault signals from points
10
Test condition.
TWINFLEXpro, 4 Zone conventional control and indicating equipment
331q/07
Incorporating:
10-0067 Main Processor Card.
Certified with the following options from EN 54 Part 2:
505-0008
7.8
Output to fire alarm devices
7.10.1
Output type A to fire protection equipment
7.11
Delays to outputs
7.12.1
Type A dependency on more than one alarm signal
8.3
Fault signals from points
10
Test condition.
TWINFLEXpro, 8 Zone conventional control and indicating equipment
331q/08
Incorporating:
10-0067 Main Processor Card
10-0087 4 Zone expansion card.
Certified with the following options from EN 54 Part 2:
7.8
7.10.1
7.11
7.12.1
8.3
10
20 Oct 2014
Output to fire alarm devices
Output type A to fire protection equipment
Delays to outputs
Type A dependency on more than one alarm signal
Fault signals from points
Test condition.
57
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Firelite by Honeywell (Pittway Systems Technology Group (Europe) Ltd)
Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom
Tel: +44 1444 230 300 • Fax: +44 1444 230 888
E-mail: [email protected]
Certificate No: 154g to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
FLS2-8 2 Zone
FLS2-8 4 Zone
FLS2-8 8 Zone
002-475-122 Language region 1, light grey
002-489-122 Language region 1, light grey, English manual
002-475-222 Language region 2, light grey
002-489-222 Language region 2, light grey, English manual
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Output to automatic fire protection equipment: Type A
7.10.3
Output to automatic fire protection equipment: Type C
7.10.4
Fault monitoring of fire protection equipment
7.11.1
Delays to outputs
7.11.2
Manual or automatic switching of delays to outputs
7.12.2
Dependency on more than one alarm signal: Type B
8.9
Output to fault warning routing equipment
10
Test condition
002-475-142 Language region 1, light grey
002-489-142 Language region 1, light grey, English manual
002-475-242 Language region 2, light grey
002-489-242 Language region 2, light grey, English manual
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Output to automatic fire protection equipment: Type A
7.10.3
Output to automatic fire protection equipment: Type C
7.10.4
Fault monitoring of fire protection equipment
7.11.1
Delays to outputs
7.11.2
Manual or automatic switching of delays to outputs
7.12.2
Dependency on more than one alarm signal: Type B
8.9
Output to fault warning routing equipment
10
Test condition
002-475-182 Language region 1, light grey
002-489-182 Language region 1, light grey, English manual
002-475-282 Language region 2, light grey
002-489-282 Language region 2, light grey, English manual
LPCB Ref.
No.
154g/06
154g/07
154g/08
Incorporating the following units:
020-747 8-way relay kit
020-772 4-way monitored sounder kit
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Output to automatic fire protection equipment: Type A
7.10.3
Output to automatic fire protection equipment: Type C
7.10.4
Fault monitoring of fire protection equipment
7.11.1
Delays to outputs
7.11.2
Manual or automatic switching of delays to outputs
7.12.2
Dependency on more than one alarm signal: Type B
8.9
Output to fault warning routing equipment
10
Test condition
58
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Firesafe
10 Sanderson Way, Marton, Blackpool FY4 4NB, United Kingdom
Tel: 01253 699500 • Fax: 01253 699550
E-mail: [email protected] • Website: www.firesafe.co.uk
Certificate No: 176b-(cl-1) to EN 54-2: 1997+A1: 2006 and EN 54-4: 1997+A1: 2002+A2: 2006
Certificated Products
FXP502/X
Two Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo
Protocol, Metal housing
LPCB Ref.
No.
176b/02
Incorporating the following units:
SPF0706000
SPF0501201
SPF0501200
Switch Mode Power supply board
XFP Apollo 2 Loop, Main motherboard
Display board Keypad Display
Certified with the following options with requirements from EN 54-2:1997
FXP501/X
7.8
Output to fire alarm device(s)
7.11
Delays to the auctioning of outputs fire alarm devices and fire routing
equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.12.2
Dependencies on more than one alarm signal - Type B
7.12.3
Dependencies on more than one alarm signal - Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality.
One Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo
Protocol, Metal housing
176b/04
Incorporating the following units:
SPF0706000
SPF0501211
SPF0501200
Switch Mode Power supply board
XFP Apollo 1 Loop, Main motherboard
Display board Keypad Display
Certified with the following options with requirements from EN 54-2:1997
FXP501E/X
7.8
Output to fire alarm device(s)
7.11
Delays to the auctioning of outputs fire alarm devices and fire routing
equipment
7.12.1
Dependencies on more than one alarm signal Type A
7.12.2
Dependencies on more than one alarm signal Type B
7.12.3
Dependencies on more than one alarm signal Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality.
One Loop, 16 Zone Analogue addressable control and indicating equipment using Apollo
protocol, Plastic housing
176b/06
Incorporating the following units:
SPF0702480
SPF0501101
Switch Mode Power supply board
XFP Apollo 1 Loop, Main motherboard
Certified with the following options with requirements from EN 54-2:1997
7.8
Output to fire alarm device(s)
7.11
Delays to the auctioning of outputs fire alarm devices and fire routing
equipment
7.12.1
Dependencies on more than one alarm signal Type A
20 Oct 2014
59
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
FCFP2N
LPCB Ref.
No.
7.12.2
Dependencies on more than one alarm signal Type B
7.12.3
Dependencies on more than one alarm signal Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality.
Two zone conventional control and indicating equipment
176b/07
Incorporating the units:
SPF0702480
SPF0724851
Switch mode power supply unit board
2 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
FCFP4N
7.8
Output to fire alarm devices(s)
7.11
Delays to outputs
10
Test condition
Four zone conventional control and indicating equipment
176b/08
Incorporating the units:
SPF0702480
SPF0724853
Switch mode power supply unit board
4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
FCFP8N
7.8
Output to fire alarm devices(s)
7.11
Delays to outputs
10
Test condition
Eight zone conventional control and indicating equipment
176b/09
Incorporating the units:
SPF0702480
SPF0724855
Switch mode power supply unit board
8 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8
7.11
10
Output to fire alarm devices(s)
Delays to outputs
Test condition
Gent By Honeywell (Novar Systems Ltd)
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom
Tel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300
E-mail: [email protected] • Website: www.gent.co.uk
Middle East Sales Enquiries
E-mail: [email protected]
Certificate No: 042x to EN 54: Parts 2 & 4: 1997
Certificate No: 042bb to EN 54-2: 1997 and EN 54-4: 1997
Certificate No: 042bm to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 and EN 54-16: 2008
Certificate No: 042bc to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
AS-2000
60
Two loop analogue addressable control and indicating equipment
Incorporating as modular units:
2434-824 Power supply
2434-710 Loop Processor Card
LPCB Ref.
No.
042bb/01
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
Nano-24
LPCB Ref.
No.
2434-833 Master Control Card
2434-825 Optical Network Card*
2434-821 Message Store Card*
2434-822 Mother board
2434-835 H.M.I
2434-840 Cold fire card
2434-796 Addressable speaker card (Optional Card)*
2434-826 Addressable daughter speaker card (Optional Card)*
2434-780 Audio Input Card (Optional Card)*
2434-781 Audio Output Card (Optional Card)*
Scope of approval does not include the functionality of the network card and optional
voice alarm system cards.
Certified with the following options from EN 54 Part 2: 1997
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Single loop analogue addressable control and indicating equipment
Incorporating as modular units:
2434-881 Mother board
2434-862 Power supply
2434-887 H.M.I (Human Machine Interface)
042bc/01
Nano-24-SP
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
10
Test condition
Single loop analogue addressable control and indicating equipment (Spanish Language
Variant)
Incorporating as modular units:
2434-881 Mother board
2434-862 Power supply
2434-887 H.M.I (Human Machine Interface)
042bc/02
Nano-24-PO
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
10
Test condition
Single loop analogue addressable control and indicating equipment
(Portuguese Language Variant)
Incorporating as modular units:
2434-881 Mother board
2434-862 Power supply
2434-887 H.M.I (Human Machine Interface)
042bc/03
Vigilon Compact-24-N
Vigilon Compact-24-PO
20 Oct 2014
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
10
Test condition
Two loop analogue addressable control and indicating equipment
(English language)
Incorporating as modular units:
2434-859 Master Controller Board (MCB)
2434-862 Power Supply Unit
2434-762 Display and Key card (DKC)
2434-669 Loop processor card
4374-161 Text Membrane (English)
2434-861 Copper network card
(Note: Scope of approval does not include the operation of the network card)
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Two loop analogue addressable control and indicating equipment
(Portuguese language variant)
042bc/04
042bc/05
61
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating as modular units:
2434-859 Master Controller Board (MCB)
2434-862 Power Supply Unit
2434-762 Display and Key card (DKC)
2434-669 Loop processor card
4374-163 Text Membrane (Portuguese)
2434-861 Copper network card
(Note: Scope of approval does not include the operation of the network card)
Vigilon Compact-24-SP
Vigilon VIG1-24
Vigilon VIG1-24-NP
Vigilon VIG1-24-PO
62
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
Two loop analogue addressable control and indicating equipment
(Spanish language variant)
Incorporating as modular units:
2434-859 Master Controller Board (MCB)
2434-862 Power Supply Unit
2434-762 Display and Key card (DKC)
2434-669 Loop processor card
4374-162 Text Membrane (Spanish)
2434-861 Copper network card
(Note: Scope of approval does not include the operation of the network card)
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
One to Four loop analogue addressable control and indicating equipment
(English language)
Incorporating as modular units:
2434-863 Master controller card (M.C.C)
2434-710 Loop card
2434-831 Power supply PCB
2434-854 Backplane PCB
2434-861 Display and Key card (D.K.C)
2434-864 Terminal card
2434-565 Printer Module
4374-157 Text Membrane (English)
2434-674 Copper network card
(Note: Scope of approval does not include the operation of the network card)
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
One to Four loop analogue addressable control and indicating equipment
(English language variant without printer module)
Incorporating as modular units:
2434-863 Master controller card (M.C.C)
2434-710 Loop card
2434-831 Power supply PCB
2434-854 Backplane PCB
2434-861 Display and Key card (D.K.C)
2434-864 Terminal card
4374-157 Text Membrane (English)
2434-674 Copper network card
(Note: Scope of approval does not include the operation of the network card)
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
One to Four loop analogue addressable control and indicating equipment
(Portuguese language variant without printer module)
Incorporating as modular units:
2434-863 Master controller card (M.C.C)
042bc/06
042bc/07
042bc/08
042bc/09
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2434-710 Loop card
2434-831 Power supply PCB
2434-854 Backplane PCB
2434-861 Display and Key card (D.K.C)
2434-864 Terminal card
4374-159 Text Membrane (Portuguese)
2434-674 Copper network card
(Note: Scope of approval does not include the operation of the network card)
Vigilon VIG1-24-SP
Vigilon VIG1-72
Vigilon VIG1-72-PO
20 Oct 2014
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
One to Four loop analogue addressable control and indicating equipment
(Spanish language variant without printer module)
Incorporating as modular units:
2434-863 Master controller card (M.C.C)
2434-710 Loop card
2434-831 Power supply PCB
2434-854 Backplane PCB
2434-861 Display and Key card (D.K.C)
2434-864 Terminal card
2434-565 Printer Module
4374-158 Text Membrane (Spanish)
2434-674 Copper network card
(Note: Scope of approval does not include the operation of the network card)
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
One to Six loop analogue addressable control and indicating equipment
(English Language)
Incorporating as modular units:
2434-863 Master controller card (M.C.C)
2434-710 Loop card
2434-992 Thermistor board
2434-860 Battery terminal board
2434-832 Power supply PCB
2434-854 Backplane PCB
2434-761 Display and Key card (D.K.C)
2434-864 Terminal card
2434-565 Printer module
4374-157 Text Membrane (English)
2434-674 Copper network card
(Note: Scope of approval does not include the operation of the network card)
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
One to Six loop analogue addressable control and indicating equipment
(Portuguese Language Variant without printer module)
Incorporating as modular units:
2434-863 Master controller card (M.C.C)
2434-710 Loop card
2434-992 Thermistor board
2434-860 Battery terminal board
2434-832 Power supply PCB
2434-854 Backplane PCB
2434-761 Display and Key card (D.K.C)
2434-864 Terminal card
2434-565 Printer module
4374-159 Text Membrane (Portuguese)
2434-674 Copper network card
(Note: Scope of approval does not include the operation of the network card)
042bc/10
042bc/11
042bc/12
63
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
Vigilon VIG1-72-SP
Compact VA
LPCB Ref.
No.
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
One to Six loop analogue addressable control and indicating equipment
(Spanish Language Variant without printer module)
Incorporating as modular units:
2434-863 Master controller card (M.C.C)
2434-710 Loop card
2434-992 Thermistor board
2434-860 Battery terminal board
2434-832 Power supply PCB
2434-854 Backplane PCB
2434-761 Display and Key card (D.K.C)
2434-864 Terminal card
2434-565 Printer module
4374-158 Text Membrane (Spanish)
2434-674 Copper network card
(Note: Scope of approval does not include the operation of the network card)
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Two loop voice alarm CIE with distributed mains powered amplifier
042bc/13
042bm/01
Incorporating as modular units within the Compact-VA:
2434-669LUGI
Compact Loop Card
2434-859LUGI
Compact Network Control Card
2434-862LUGI
Compact Network PSU Card
2434-870LUGI
Multiformat DKC Compact VA
2434-792 Audio Control Card
2434-023 MPEG Speech Card
2434-722 ACU DKC Card
Incorporating as modular units within the Distributed Amplifier Unit:
2434-897LUGI
Mains powered DAU PSU Card
2434-875 Mains Powered DAU Control Card
2434-876 Mains Powered DAU Amplifier
2434-880 MPEG Speech Card
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Certified with the following options with requirements from EN 54-16:
7.3
Audible warning
7.6.2
Manual silencing of the voice alarm condition
7.7.2
Manual reset of the voice alarm condition
7.8
Output to fire alarm devices
8.3
Indication of faults related to the transmission path to the CIE
8.4
Indication of faults related to voice alarm zones
12.0
Emergency microphones
13.14
Redundant power amplifiers
Notes:
1. This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
13270-01
64
1 zone conventional control and indicating equipment
Certified with the following options from EN 54 Part 2: 1997
7.8
Output to fire alarm devices
7.11
Delays of actioning to outputs to fire alarm routing equipment
10
Test condition
042x/01
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
Xenex 1 13270-01LB
13270-02
Xenex 2 13270-02LB
13270-04
Xenex 4 13270-04LB
13270-08
Xenex 8 13270-08LB
1 zone conventional control and indicating equipment
(Xenex brand)
Certified with the following options from EN 54 Part 2: 1997
7.8
Output to fire alarm devices
7.11
Delays of actioning to outputs to fire alarm routing equipment
10
Test condition
2 zone conventional control and indicating equipment
Certified with the following options from EN 54 Part 2: 1997
7.8
Output to fire alarm devices
7.11
Delays of actioning to outputs to fire alarm routing equipment
10
Test condition
2 zone conventional control and indicating equipment
(Xenex brand)
Certified with the following options from EN 54 Part 2: 1997
7.8
Output to fire alarm devices
7.11
Delays of actioning to outputs to fire alarm routing equipment
10
Test condition
4 zone conventional control and indicating equipment
Certified with the following options from EN 54 Part 2: 1997
7.8
Output to fire alarm devices
7.11
Delays of actioning to outputs to fire alarm routing equipment
10
Test condition
4 zone conventional control and indicating equipment
brand)
Certified with the following options from EN 54 Part 2: 1997
7.8
Output to fire alarm devices
7.11
Delays of actioning to outputs to fire alarm routing equipment
10
Test condition
8 zone conventional control and indicating equipment
Certified with the following options from EN 54 Part 2: 1997
7.8
Output to fire alarm devices
7.11
Delays of actioning to outputs to fire alarm routing equipment
10
Test condition
8 zone conventional control and indicating equipment
(Xenex brand)
Certified with the following options from EN 54 Part 2: 1997
7.8
Output to fire alarm devices
7.11
Delays of actioning to outputs to fire alarm routing equipment
10
Test condition
LPCB Ref.
No.
042x/01
042x/02
042x/02
042x/03
042x/03
042x/04
042x/04
Gulf Security Technology Co., Ltd.
No 80 Changjiang East Road, QETDZ, Qinhuangdao, Hebei Province 066004, China
Tel: +86 0335 8502434 • Fax: +86 0335 8502532
E-mail: [email protected] • Website: www.gst.com.cn
Sales Beijing:
Tel: +86 (10) 6439 1866 • Fax: +86 (10) 6439 1787
Sales Hong Kong:
Tel: +852 2877 8566 • Fax: +852 2511 8699
Certificate No: 548j to EN 54-2:1997, EN 54-4:1997 + A1: 2002
Control and indicating equipment
Certificated Products
GST-200
Intelligent 1 loop, 30 zone, analogue addressable control and indicating equipment
Incorporating the following units:
F7.820.826
F7.908.312
F7.820.827
20 Oct 2014
LPCB Ref.
No.
548j/01
Main board
Zone indication board
Switch board
65
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
F7.820.828
F7.820.829
F2.910.093
R150
CGM12864
F2.828.630a
GST 101
GST 102
GST 104
GST 108
GST 116
Loop interface board
Power Supply unit
Mains filter
Transformer
Alphanumeric Display
Printer board (option)
Incorporating as optional modular units:
P-9901
Printer module kit
F7.820.170
RS232 board for configuration
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
7.10
Output to automatic Fire Protection Equipment
7.11
Delays to outputs
7.12
Coincidence detection
8.3
Fault signals from points
9.5
Disablement of addressable points
Single zone conventional control and indicating equipment
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
10
Test condition
Two zone conventional control and indicating equipment
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
10
Test condition
Four zone conventional control and indicating equipment
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
7.11
Delays to outputs
10
Test condition
Eight zone conventional control and indicating equipment
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
7.11
Delays to outputs
10
Test condition
Sixteen zone conventional control and indicating equipment
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
7.11
Delays to outputs
10
Test condition
548j/02
548j/03
548j/04
548j/08
548j/09
Certificate No: 548p to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
GST200-2
Intelligent 2 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment
Incorporating the following units:
MB-220/ F7.820.826
SB-220/ F7.820.827
TB-220/ F7.820.828
PS-220/ F7.820.829b
ZP-220/ F7.820.312d
LC200/ F7.820.1125
LPCB Ref.
No.
548p/01
Main board
Switch board
Loop interface board
Power supply unit
Zone indication and intervention board
Loop board
Incorporating as optional modular units:
P-9930/ F7.820.913a
RS-232 board for configuration
P-9901A
Printer module kit
GST-IFP8
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
7.10.1
Output to automatic Fire Protection Equipment
Type A
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
Intelligent 8 loop, 140 zone analogue addressable
control and indicating equipment
548p/02
Incorporating the following units:
66
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
SB-800/ F7.820.1238
LCIFP8/ F7.820.1239
PB-800/ F7.820.1311
ZP-800/ F7.820.1312
KB-800/ F7.820.1326
MB-800/ F7.820.1237
MO-800/ F7.820.1310
Indication board
Loop board
Power board
ZCP board
Keypad board
Main board
Mother board
Incorporating as optional modular units:
P-9935/ F7.820.1313
USB communication board
Optional language variants:
10104673
10104675
GST102A
Portuguese language variant
Hungarian language variant
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire routing
equipment
7.9.2
Alarm confirmation input
from fire routing equipment
7.10.1
Output type A
7.10.2
Output type B
7.11
Delays to outputs
7.12.1
Dependencies on more
than one alarm signal - Type A
7.12.2
Dependencies on more
than one alarm signal - Type B
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each
address point
10
Test condition
2 Zone conventional control and indicating equipment
548p/03
Incorporating the following modules:
FC-102A/ F7.843.399
Membrane
CB-102A/ F2.908.1719
Control board with integrated PSE
DB-102A/ F2.908.1722
Display board
Optional modules:
10104648 Traditional Chinese text variant
CF-102A/ F7.843.421
Membrane
GST104A
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire routing equipment
7.11
Delays to outputs
10
Test condition
4 Zone conventional control and indicating equipment
548p/04
Incorporating the following modules:
FC-104A/ F7.843.400
Membrane
CB-104A/ F2.908.1718
Control board with integrated PSE
DB-104A/ F2.908.1721
Display board
Optional modules:
10104649 Traditional Chinese text variant
CF-104A/ F7.843.422
Membrane
GST108A
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire routing equipment
7.11
Delays to outputs
10
Test condition
8 Zone conventional control and indicating equipment
548p/05
Incorporating the following modules:
FC-108A/ F7.843.401
Membrane
CB-108A/ F2.908.1675
Control board with integrated PSE
DB-108A/ F2.908.1720
Display board
20 Oct 2014
67
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Optional modules:
10104650
Traditional Chinese text variant
CF-108A/ F7.843.423
Membrane
GST116A
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire routing equipment
7.11
Delays to outputs
10
Test condition
16 Zone Conventional Control and Indicating Equipment
Incorporating the following modules:
FC-116A/ F7.843.402
CB-116A/ F2.908.1724
DB-116A/ F2.908.1676
XB-116A/ F7.820.1677
Optional modules:
10104651
CF-116A/ F7.843.424
GST200N
548p/06
Membrane
Control board with integrated PSE
Display board
Expansion board
Traditional Chinese text variant
Membrane
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire routing equipment
7.11
Delays to outputs
10
Test condition
Intelligent 2 loop, 30 zone analogue addressable control and indicating equipment
548p/07
Incorporating the following units:
MB-220/ F7.820.826a
Main board
P-9960A/ F7.820.1943
CAN network card loop type board
PS-220/ F7.820.1939
Power management board
OX-220/ F7.820.1857
Terminal board
ZP-220/ F7.820.312d
Zone indication and intervention board
SB-220/ F7.820.827
Switch board
TB-220/ F7.820.828a
Loop interface board
LC200/ F7.820.1125
Loop board
PDF-150-27.5.
Powerld SMPS 100-240V power supply
Incorporating as optional modular units:
P-9930/ F7.820.913a
RS-232 board for configuration
P-9901A Printer module kit
Optional language variants:
10104672 Portuguese language variant
10104674 Hungarian language variant
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
7.10.1
Output to automatic Fire Protection Equipment Type A
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
GST200-2/1
Note : Scope of approval does not include network functionality.
Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment
548p/08
Incorporating the following units:
MB-220/ F7.820.826
Main board
SB-220/ F7.820.827
Switch board
TB-220/ F7.820.828
Loop interface board
PS-220/ F7.820.829b
Power supply unit
ZP-220/ F7.820.913a
Zone indication and intervention board
Incorporating as optional modular units:
P-9930/ F7.820.913a
RS-232 board for configuration
P-9901A
Printer module kit
LC200/ F7.820.1125
Loop board (for loop expansion)
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
68
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.10.1
Type A
7.11
8.3
9.5
GST200-2/1PT
Output to automatic Fire Protection Equipment
Delays to outputs
Fault signals from points
Disablement of addressable points
Note: can be extended to 2 loop panel by adding LC200
Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment
Incorporating the following units:
MB-220/ F7.820.826
SB-220/ F7.820.827
TB-220/ F7.820.828
PS-220/ F7.820.829b
ZP-220/ F7.820.312d
548p/09
Main board
Switch board
Loop interface board
Power supply unit
Zone indication and intervention board
Incorporating as optional modular units:
P-9930/ F7.820.913a
RS-232 board for configuration
P-9901A
Printer module kit
LC200/ F7.820.1125
Loop board (for loop expansion)
GST200-2/1HU
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
7.10.1
Output to automatic Fire Protection Equipment
Type A
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating
Equipment (Hungarian Varient)
Incorporating the following units:
MB-220/ F7.820.826
SB-220/ F7.820.827
TB-220/ F7.820.828
PS-220/ F7.820.829b
ZP-220/ F7.820.312d
board
548p/10
Main board
Switch board
Loop interface board
Power supply unit
Zone indication and intervention
Incorporating as optional modular units:
P-9930/ F7.820.913a
RS-232 board for configuration
P-9901A
Printer module kit
LC200/ F7.820.1125
Loop board (for loop expansion)
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
7.10.1
Output to automatic Fire Protection
Equipment Type A
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
Note: Can be extended to 2-loop panel by adding LC200
Haes Systems Limited
Columbia House, Packet Boat Lane, Cowley Peachey, Uxbridge, Middlesex UB8 2JP, United Kingdom
Tel: +44 (0)1895 422066 • Fax: +44 (0)1895 420603
E-mail: [email protected] • Website: www.haes-systems.co.uk
Certificate No: 810a to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
FBUS X-Y-Z
20 Oct 2014
1 to 4 Loop analogue addressable and/or 4-20 Zone conventional
control and indicating equipment
LPCB Ref.
No.
810a/01
69
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating as modular units:
FSB17 Main Display PCB
FSB10 Expander PCB
PSUFUSION-3A 3A Power Supply Control PCB
PSULS100-36 36V 100W Lambda Power supply Module
Cabinet size 340H x 460W x 120D mm
and as optional modules:
FSB18
FSB11
FSB10-E
FSB12-32
FSB12-64
4 Way Conventional zone PCB
1 Loop Card Apollo protocol
Bank Extender PCB
16 Way expansion LED PCB
48 Way expansion LED PCB
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.11
Delays to outputs
9.5
Disablement of each addressable point
10
Test condition
Notes:
1.
FBUL X-Y-Z
Model name suffix X denote the LED display module type, Y denote the
number of conventional zones and Z denote the number of loops.
2. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
1 to 8 Loop analogue addressable and/or 4-64 zone conventional
control and indicating equipment
810a/02
Incorporating as modular units:
FSB17 Main Display PCB
FSB10 Expander PCB
PSUFUSION-5A 5A Power Supply Control PCB
PSULS150-36 36V 150W Lambda Power supply Module
Cabinet size 750H x 470W x 140D mm
and as optional modules:
FSB18
FSB11
FSB10-E
FSB12-32
FSB12-64
4 Way Conventional zone PCB
1 Loop Card Apollo protocol
Bank Extender PCB
16 Way expansion LED PCB
48 Way expansion LED PCB
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.11
Delays to outputs
9.5
Disablement of each addressable point
10
Test condition
Notes:
1.
ECLiPSE
Model name suffix X denote the LED display module type, Y denote the
number of conventional zones and Z denote the number of loops.
2. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
4 and 2 Zone conventional control and indicating equipment
810a/03
ECL-2
Incorporating as modular units:
TPC A01- E2 Eclipse two zone main PCB applicable on 2 zone CIE only
TPC A02 ZoneFinder LED display PCB
PSM1.5 - 24 Power supply 1.5A rated
Certified with the following options with requirements from EN 54 Part 2:
7.8 Output to fire alarm devices
7.12.1 Dependency on more than one alarm signal type A
10 Test condition
EC-4
70
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating as modular units:
TPC A01- E4 Eclipse four zone main PCB applicable on 4 zone CIE only
TPC A02 Eclipse LED display PCB
PSM1.5 - 24 Power supply 1.5A rated
Certified with the following options with requirements from EN 54 Part 2:
7.8 Output to fire alarm devices
7.12.1 Dependency on more than one alarm signal type A
10 Test condition
Note:
1. This product approval does not constitute compliance with the fire
detection and alarm systems requirements of EN 54-13.
Excel-EN
2,4, 6, 8 and 12 Zone conventional control and indicating equipment
810a/04
Excel-EN 2 Zone Conventional Control Panel (Manufacturers internal code XLEN-2)
Incorporating as modular units:
TPCA01-X 2 XLEN 2 Zone Main PCB
TPCA03 XLEN Display Board
PSM3.0-24 Power Supply
Excel-EN 4 Zone Conventional Control Panel (Manufacturers internal code XLEN-4)
Incorporating as modular units:
TPCA01-X4 XLEN 4 Zone Main PCB
TPCA03 XLEN Display Board
PSM3.0-24 Power Supply
Excel-EN 6 Zone Conventional Control Panel (Manufacturers internal code XLEN-6H)
Incorporating as modular units:
TPCA01-X2 XLEN 2 Zone Main PCB
TPCA03 XLEN Display Board
TPCA04-H XLEN High Spec 4 Zone Extension Board
PSM3.0-24 Power Supply
Excel-EN 6 Zone Conventional Control Panel (Manufacturers internal code XLEN-6)
Incorporating as modular units:
TPCA01-X2 XLEN 2 Zone Main PCB
TPCA03 XLEN Display Board
TPCA04-S XLEN Standard 4 Zone Extension Board
PSM3.0-24 Power Supply
Excel-EN 8 Zone Conventional Control Panel (Manufacturers internal code XLEN-8)
Incorporating as modular units:
TPCA01-X4 XLEN 4 Zone Main PCB
TPCA03 XLEN Display Board
TPCA04-H XLEN High Spec 4 Zone Extension Board
PSM3.0-24 Power Supply
Excel-EN 8 Zone Conventional Control Panel (Manufacturers internal code XLEN-8L)
Incorporating as modular units:
TPCA01-X4 XLEN 4 Zone Main PCB
TPCA03 XLEN Display Board
TPCA04-S XLEN Standard 4 Zone Extension Board
PSM3.0-24 Power Supply
Excel-EN 12 Zone Conventional Control Panel (Manufacturers internal code XLEN-12)
Incorporating as modular units:
TPCA01-X4 XLEN 4 Zone Main PCB
TPCA03 XLEN Display Board
TPCA04-S XLEN Standard 4 Zone Extension Board
TPCA04-H XLEN High Spec 4 Zone Extension Board
PSM3.0-24 Power Supply
Excel-EN 12 Zone Conventional Control Panel (Manufacturers internal code XLEN-12L)
Incorporating as modular units:
TPCA01-X4 XLEN 4 Zone Main PCB
TPCA03 XLEN Display Board
TPCA04-S Two XLEN Standard 4 Zone Extension Board
PSM3.0-24 Power Supply
20 Oct 2014
71
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Excel-EN 12 Zone Conventional Control Panel (Manufacturers internal code XLEN-12H)
Incorporating as modular units:
TPCA01-X4 XLEN 4 Zone Main PCB
TPCA03 XLEN Display Board
TPCA04-H Two XLEN High Spec 4 Zone Extension Board
PSM3.0-24 Power Supply
Certified with the following options with requirements from EN 54 Part 2:
AlarmSense
7.8 Output to fire alarm devices
7.11 Delays to outputs
7.12.1 Dependency on more than one alarm signal type A
7.12.2 Dependency on more than one alarm signal type B
7.12.3 Dependency on more than one alarm signal type C
10 Test condition
Note:
1. This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
ALS-2 2 Zone AlarmSense conventional control and indicating equipment ALS-4 4 Zone
AlarmSense conventional control
and indicating equipment
810a/05
Incorporating as modular units:
TPCA02 Eclipse LED Display & Controls Board
TPCA06-A2 AlarmSense, 2 Zone main PCB
TPCA06-A4 AlarmSense, 4 Zone main PCB (applicable on 4 zone CIE only)
PSM1.5 - 24 Power supply 1.5A rated
Certified with the following options with requirements from EN 54 Part 2:
7.8 Output to fire alarm devices
7.12.1 Dependency on more than one alarm type A
10 Test condition
Note:
1. This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
AlarmSense Plus
2,4, 6, 8 and 12 Zone AlarmSense conventional
control and indicating equipment
810a/06
ASP-2 2 Zone AlarmSense Conventional Control Panel
Incorporating as modular units:
TPCA03 XLEN LED Display & Controls Board
TPCA06-P2 AlarmSense Plus, 2 Zone main PCB
PSM3.0-24 Power Supply
Incorporating as optional module:
TPCA05 XLEN Communications Board
ASP-4 4 Zone AlarmSense Conventional Control Panel
Incorporating as modular units:
TPCA03 XLEN LED Display & Controls Board
TPCA06-P4 AlarmSense Plus, 4 Zone main PCB
PSM3.0-24 Power Supply
Incorporating as optional module:
TPCA05 XLEN Communications Board
ASP-6 6 Zone AlarmSense Conventional Control Panel
Incorporating as modular units:
TPCA03 XLEN LED Display & Controls Board
TPCA06-P2 AlarmSense Plus, 2 Zone main PCB
TPCA07 AlarmSense Plus, 4 zone extension card
PSM3.0-24 Power Supply
72
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating as optional module:
TPCA05 XLEN Communications Board
ASP-8 8 Zone AlarmSense Conventional Control Panel
Incorporating as modular units:
TPCA03 XLEN LED Display & Controls Board
TPCA06-P4 AlarmSense Plus, 4 Zone main PCB
TPCA07 AlarmSense Plus, 4 zone extension card
PSM3.0-24 Power Supply
Incorporating as optional module:
TPCA05 XLEN Communications Board
ASP-12 12 Zone AlarmSense Conventional Control Panel
Incorporating as modular units:
TPCA03 XLEN LED Display & Controls Board
TPCA06-P4 AlarmSense Plus, 4 Zone main PCB
TPCA07 AlarmSense Plus, 4 zone extension card x 2
PSM3.0-24 Power Supply
Incorporating as optional module:
TPCA05 XLEN Communications Board
Certified with the following options with requirements from EN 54 Part 2:
7.8 Output to fire alarm devices
7.11 Delays to outputs
7.12.1 Dependency on more than one alarm signal type A
7.12.2 Dependency on more than one alarm signal type B
7.12.3 Dependency on more than one alarm signal type C
10 Test condition
HSC
Note:
1. This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
4 and 2 Zone conventional control and indicating equipment
810a/07
HSC-2
Incorporating as modular units:
TPCHSC-2 HSC two zone main PCB applicable on 2 zone CIE only
TPC A02 HSC LED display PCB
PSM1.5 - 24 Power supply 1.5A rated
Certified with the following options with requirements from EN 54 Part 2:
7.8 Output to fire alarm devices
7.12.1 Dependency on more than one alarm signal type A
10 Test condition
HSC-4
Incorporating as modular units:
TPCHSC-4 HSC four zone main PCB applicable on 4 zone CIE only
TPC A02 HSC LED display PCB
PSM1.5 - 24 Power supply 1.5A rated
Certified with the following options with requirements from EN 54 Part 2:
7.8 Output to fire alarm devices
7.12.1 Dependency on more than one alarm signal type A
10 Test condition
Note:
1. This product approval does not constitute compliance with the fire
detection and alarm systems requirements of EN 54-13
20 Oct 2014
73
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Honeywell Control Systems Ltd
Honeywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United Kingdom
Tel: 01344 655609 • Fax: 01344 655474
Website: www.honeywell.com
Certificate No: 154g-(cl-1) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
XLS80e
Basic Equipment Kit, (BEK): Modular analogue addressable control and indicating
equipment.
020-538-101
XLS80e Basic Equipment Kit, Group 1
020-538-103
XLS80e Basic Equipment Kit, Group 3
020-538-104
XLS80e Basic Equipment Kit, Group 4
020-538-105
XLS80e Basic Equipment Kit, Group 5
LPCB Ref.
No.
154g/01
Incorporating the following as modular units:
Enclosures:
020-040-002
Cover Kit Extended Moulded, Light / Grey
020-472-002
Backbox Kit Standard, Light Grey
020-473-002
Backbox Kit Extended, Light Grey
020-474-002
Backbox Kit Extended Deep, Light Grey
020-475-002
Backbox Kit Double Extended, Light Grey
020-476-002
Backbox Kit Double Extended Deep, Light Grey
020-480-102
Main Cover Kit, Light / Grey
020-481-002
Extension Cover Kit, Light / Grey
020-509-002
Backbox Extension Deep Assembly Light / Grey
020-621-002
256 Zone Extension Cover, Light / Grey
020-541-102
PSU7A / 78Ah Battery Enclosure
Modules:
020-708-100
Extension Chassis with Printer Kit
020-644-009
Printer Assembly
020-559-101
Zone Extension Chassis Kit 1-64 Zone C/W Display Module
020-559-102
Zone Extension Chassis Kit 65-128 Zone C/W Display Module
020-612-100
Double Extended Chassis Kit 256 Zone
020-708-009
Extension Chassis with Printer
020-644-009
Printer Assembly
020-588-100
Honeywell Dual Loop Interface Board, (LIB)
020-549-100
Honeywell Dual Enhanced Loop Interface Board, (ELIB)
020-478
RS232 Interface
020-479
RS485 Interface
020-648
PSU3A
020-579
PSU7A, (Requires Dual Transmission Path / Booster, PSU
Interface)
020-548
PSU7A Status Indication
020-543
Dual Transmission Path / Booster, PSU Interface
020-773
Routing Termination Unit (DEOL)
020-877
Extinguishing Interface Module M221-SI
020-643
XLS80e-NI Fibre Optic Interface Kit
020-647-100
XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e
Panel
Certified with the following options with requirements:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Output to fire protection equipment type A
7.10.3
Output to fire protection equipment type C
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.2
Dependency on more than one alarm signal type B
7.12.3
Dependency on more than one alarm signal type C
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablements of addressable points
10
Test condition
Note 1: Products are available in language variants as follows:
Group 1: English, Spanish, Portuguese, Icelandic and Italian
74
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Group 3: English, Swedish, Danish, Norwegian and Finish
Group 4: English, Czech and Polish
Group 5: English and Cyrillic
XLS80e-2L
Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.
Fixed build 2 loop analogue addressable control and indicating equipment.
020-692
XLS80e-2L-1, 2 Loop, PSU3A, Group 1
020-692-103
XLS80e-2L-3, 2 Loop, PSU3A, Group 3
020-692-104
XLS80e-2L-4, 2 Loop, PSU3A, Group 4
020-692-105
XLS80e-2L-5, 2 Loop, PSU3A, Group 5
154g/01
Incorporating the following as modular units:
Enclosures:
020-040-002
Cover Kit Extended Moulded, Light / Grey
020-472-002
Backbox Kit Standard, Light Grey
020-473-002
Backbox Kit Extended, Light Grey
020-474-002
Backbox Kit Extended Deep, Light Grey
020-475-002
Backbox Kit Double Extended, Light Grey
020-476-002
Backbox Kit Double Extended Deep, Light Grey
020-480-102
Main Cover Kit, Light / Grey
020-481-002
Extension Cover Kit, Light / Grey
020-509-002
Backbox Extension Deep Assembly Light / Grey
020-621-002
256 Zone Extension Cover, Light / Grey
020-541-102
PSU7A / 78Ah Battery Enclosure
Modules:
020-708-100
Extension Chassis with Printer Kit
020-644-009
Printer Assembly
020-559-101
Zone Extension Chassis Kit 1-64 Zone C/W Display Module
020-559-102
Zone Extension Chassis Kit 65-128 Zone C/W Display Module
020-612-100
Double Extended Chassis Kit 256 Zone
020-708-009
Extension Chassis with Printer
020-644-009
Printer Assembly
020-588-100
Honeywell Dual Loop Interface Board, (LIB)
020-549-100
Honeywell Dual Enhanced Loop Interface Board, (ELIB)
020-478
RS232 Interface
020-479
RS485 Interface
020-648
PSU3A
020-579
PSU7A, (Requires Dual Transmission Path / Booster, PSU
Interface)
020-548
PSU7A Status Indication
020-543
Dual Transmission Path / Booster, PSU Interface
020-773
Routing Termination Unit (DEOL)
020-877
Extinguishing Interface Module M221-SI
020-643
XLS80e-NI Fibre Optic Interface Kit
020-647-100
XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e
Panel
Certified with the following options with requirements:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Output to fire protection equipment type A
7.10.3
Output to fire protection equipment type C
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.2
Dependency on more than one alarm signal type B
7.12.3
Dependency on more than one alarm signal type C
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablements of addressable points
10
Test condition
Note 1: Products are available in language variants as follows:
Group 1: English, Spanish, Portuguese, Icelandic and Italian
Group 3: English, Swedish, Danish, Norwegian and Finish
Group 4: English, Czech and Polish
Group 5: English and Cyrillic
XLS80e-4L
20 Oct 2014
Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.
Fixed build 4 loop analogue addressable control and indicating equipment.
020-693 XLS80e-4L-1, 4 Loop, PSU3A, Group 1
020-693-103
XLS80e-4L-3, 4 Loop, PSU3A, Group 3
154g/01
75
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
020-693-104
020-693-105
XLS80e-4L-4, 4 Loop, PSU3A, Group 4
XLS80e-4L-5, 4 Loop, PSU3A, Group 5
Incorporating the following as modular units:
Enclosures:
020-040-002
Cover Kit Extended Moulded, Light / Grey
020-472-002
Backbox Kit Standard, Light Grey
020-473-002
Backbox Kit Extended, Light Grey
020-474-002
Backbox Kit Extended Deep, Light Grey
020-475-002
Backbox Kit Double Extended, Light Grey
020-476-002
Backbox Kit Double Extended Deep, Light Grey
020-480-102
Main Cover Kit, Light / Grey
020-481-002
Extension Cover Kit, Light / Grey
020-509-002
Backbox Extension Deep Assembly Light / Grey
020-621-002
256 Zone Extension Cover, Light / Grey
020-541-102
PSU7A / 78Ah Battery Enclosure
Modules:
020-708-100
Extension Chassis with Printer Kit
020-644-009
Printer Assembly
020-559-101
Zone Extension Chassis Kit 1-64 Zone C/W Display Module
020-559-102
Zone Extension Chassis Kit 65-128 Zone C/W Display Module
020-612-100
Double Extended Chassis Kit 256 Zone
020-708-009
Extension Chassis with Printer
020-644-009
Printer Assembly
020-588-100
Honeywell Dual Loop Interface Board, (LIB)
020-549-100
Honeywell Dual Enhanced Loop Interface Board, (ELIB)
020-478
RS232 Interface
020-479
RS485 Interface
020-648
PSU3A
020-579
PSU7A, (Requires Dual Transmission Path / Booster, PSU
Interface)
020-548
PSU7A Status Indication
020-543
Dual Transmission Path / Booster, PSU Interface
020-773
Routing Termination Unit (DEOL)
020-877
Extinguishing Interface Module M221-SI
020-643
XLS80e-NI Fibre Optic Interface Kit
020-647-100
XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e
Panel
Certified with the following options with requirements:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Output to fire protection equipment type A
7.10.3
Output to fire protection equipment type C
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.2
Dependency on more than one alarm signal type B
7.12.3
Dependency on more than one alarm signal type C
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablements of addressable points
10
Test condition
Note 1: Products are available in language variants as follows:
Group 1: English, Spanish, Portuguese, Icelandic and Italian
Group 3: English, Swedish, Danish, Norwegian and Finish
Group 4: English, Czech and Polish
Group 5: English and Cyrillic
XLS80e-6L
Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.
Fixed build 6 loop analogue addressable control and indicating equipment.
020-694
XLS80e-6L-1, 6 Loop, PSU7A, Group 1
020-694-103
XLS80e-6L-3, 6 Loop, PSU7A, Group 3
020-694-104
XLS80e-6L-4, 6 Loop, PSU7A, Group 4
020-694-105
XLS80e-6L-5, 6 Loop, PSU7A, Group 5
154g/01
Incorporating the following as modular units:
Enclosures:
020-040-002
Cover Kit Extended Moulded, Light / Grey
020-472-002
Backbox Kit Standard, Light Grey
020-473-002
Backbox Kit Extended, Light Grey
76
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
020-474-002
020-475-002
020-476-002
020-480-102
020-481-002
020-509-002
020-621-002
020-541-102
Modules:
020-708-100
020-644-009
020-559-101
020-559-102
020-612-100
020-708-009
020-644-009
020-588-100
020-549-100
020-478
020-479
020-648
020-579
Interface)
020-548
020-543
020-773
020-877
020-643
020-647-100
Panel
Backbox Kit Extended Deep, Light Grey
Backbox Kit Double Extended, Light Grey
Backbox Kit Double Extended Deep, Light Grey
Main Cover Kit, Light / Grey
Extension Cover Kit, Light / Grey
Backbox Extension Deep Assembly Light / Grey
256 Zone Extension Cover, Light / Grey
PSU7A / 78Ah Battery Enclosure
Extension Chassis with Printer Kit
Printer Assembly
Zone Extension Chassis Kit 1-64 Zone C/W Display Module
Zone Extension Chassis Kit 65-128 Zone C/W Display Module
Double Extended Chassis Kit 256 Zone
Extension Chassis with Printer
Printer Assembly
Honeywell Dual Loop Interface Board, (LIB)
Honeywell Dual Enhanced Loop Interface Board, (ELIB)
RS232 Interface
RS485 Interface
PSU3A
PSU7A, (Requires Dual Transmission Path / Booster, PSU
PSU7A Status Indication
Dual Transmission Path / Booster, PSU Interface
Routing Termination Unit (DEOL)
Extinguishing Interface Module M221-SI
XLS80e-NI Fibre Optic Interface Kit
XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e
Certified with the following options with requirements:
7.8
Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10.1 Output to fire protection equipment type A
7.10.3 Output to fire protection equipment type C
7.10.4 Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.2 Dependency on more than one alarm signal type B
7.12.3 Dependency on more than one alarm signal type C
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablements of addressable points
10
Test condition
Note 1: Products are available in language variants as follows:
Group 1: English, Spanish, Portuguese, Icelandic and Italian
Group 3: English, Swedish, Danish, Norwegian and Finish
Group 4: English, Czech and Polish
Group 5: English and Cyrillic
XLS80e-8L
Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.
Fixed build 8 loop analogue addressable control and indicating equipment.
020-695
XLS80e-8L-1, 8 Loop, PSU7A, Group 1
020-695-103
XLS80e-8L-3, 8 Loop, PSU7A, Group 3
020-695-104
XLS80e-8L-4, 8 Loop, PSU7A, Group 4
020-695-105
XLS80e-8L-5, 8 Loop, PSU7A, Group 5
154g/01
Incorporating the following as modular units:
Enclosures:
020-040-002
Cover Kit Extended Moulded, Light / Grey
020-472-002
Backbox Kit Standard, Light Grey
020-473-002
Backbox Kit Extended, Light Grey
020-474-002
Backbox Kit Extended Deep, Light Grey
020-475-002
Backbox Kit Double Extended, Light Grey
020-476-002
Backbox Kit Double Extended Deep, Light Grey
020-480-102
Main Cover Kit, Light / Grey
020-481-002
Extension Cover Kit, Light / Grey
020-509-002
Backbox Extension Deep Assembly Light / Grey
020-621-002
256 Zone Extension Cover, Light / Grey
020-541-102
PSU7A / 78Ah Battery Enclosure
20 Oct 2014
77
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Modules:
020-708-100
020-644-009
020-559-101
020-559-102
020-612-100
020-708-009
020-644-009
020-588-100
020-549-100
020-478
020-479
020-648
020-579
Interface)
020-548
020-543
020-773
020-877
020-643
020-647-100
Panel
Extension Chassis with Printer Kit
Printer Assembly
Zone Extension Chassis Kit 1-64 Zone C/W Display Module
Zone Extension Chassis Kit 65-128 Zone C/W Display Module
Double Extended Chassis Kit 256 Zone
Extension Chassis with Printer
Printer Assembly
Honeywell Dual Loop Interface Board, (LIB)
Honeywell Dual Enhanced Loop Interface Board, (ELIB)
RS232 Interface
RS485 Interface
PSU3A
PSU7A, (Requires Dual Transmission Path / Booster, PSU
PSU7A Status Indication
Dual Transmission Path / Booster, PSU Interface
Routing Termination Unit (DEOL)
Extinguishing Interface Module M221-SI
XLS80e-NI Fibre Optic Interface Kit
XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e
Certified with the following options with requirements:
7.8
Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10.1 Output to fire protection equipment type A
7.10.3 Output to fire protection equipment type C
7.10.4 Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.2 Dependency on more than one alarm signal type B
7.12.3 Dependency on more than one alarm signal type C
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablements of addressable points
10
Test condition
Note 1: Products are available in language variants as follows:
Group 1: English, Spanish, Portuguese, Icelandic and Italian
Group 3: English, Swedish, Danish, Norwegian and Finish
Group 4: English, Czech and Polish
Group 5: English and Cyrillic
XLS80e-NI
Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.
002-467-002 Network Gateway Unit, (NGU) Honeywell Protocol
154g/NO1
Incorporating the following as modular units:
020-643 XLS80e- NI Fibre Optic Interface Kit
020-647-100
XLS80e-NI Network Gateway Module, (NGM) for use in
XLS80e Panel
020-648
PSU3A
Note 1: Products are available in language variants as follows:
Group 1: English, Spanish, Portuguese, Icelandic and Italian
Group 3: English, Swedish, Danish, Norwegian and Finish
Group 4: English, Czech and Polish
Group 5: English and Cyrillic
Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.
78
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Honeywell International Inc
1500 West Dundee Road, Arlington Heights IL 60004, USA
Tel: +1 847 797 4403 • Fax: +1 847 797 3664
Website: www.honeywell.com
Certificate No: 262z-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 262ab-(cl-1) to EN54-2: 1997+A1:2006, EN54-4:1997+A1:2002+A2:2006, EN54-16:2008
Control and indicating equipment
Certificated Products
XLS1000
Incorporating as modular units:
Annunciators
LPCB Ref.
No.
262ab/01
EST3 24 LED Annunciators
3-24Y
Annunciator Bill of Materials
3-24Y-E Annunciator Bill of Materials
3-24R
Annunciator Bill of Materials
3-24R-E Annunciator Bill of Materials
3-24G
Annunciator Bill of Materials
3-24G-E Annunciator Bill of Materials
3-12RY Annunciator Bill of Materials
3-12RY-E Annunciator Bill of Materials
EST3 18 LED Annunciators
3-6/3S1G2Y
3-6/3S1G2Y Annunciator Bill of Materials
3-6/3S1G2Y-E
3-6/3S1G2Y Annunciator Bill of Materials
3-6/3S1GYR
3-6/3S1GYR Annunciator Bill of Materials
3-6/3S1GYR-E
3-6/3S1GYR Annunciator Bill of Materials
3-6/3S2RY
3-6/3S2RY Annunciator Bill of Materials
EST3 Control-Display Switch/LEDs
3-12SY 3-12SY 12 Switch-Yellow Bill of Materials
3-12SY-E
3-12SY 12 Switch-Yellow Bill of Materials
3-12SR 3-12SR 12 Switch-Red Bill of Materials
3-12SR-E 3-12SR 12 Switch-Red Bill of Materials
3-12SG 3-12SG 12 Switch-Green Bill of Materials
3-12SG-E 3-12SG 12 Switch-Green Bill of Materials
3-12/S1GY
3-12/S1GY 12 Switch-Green/Yellow
3-12/S1GY-E
3-12/S1GY 12 Switch-Green/Yellow
3-12/S1RY
3-12/S1RY 12 Switch-Red/Yellow Bill of Materials
3-12/S1RY-E
3-12/S1RY 12 Switch-Red/Yellow Bill of Materials
3-12/S2Y 3-12/S2Y - 12 Switches - 24 Yellow Bill of Materials
3-12/S2R 3-12/S2R - 12 Switches - 24 Red Bill of Materials
Loop Controller Modules
3-SSDC1-E
Signature (Single), driver controller module
3-DSDC1-E
Signature (Dual), driver controller module
3-AADC1-E
System Sensor driver control module
3-SDC1-E
Signature, driver controller module
3-EAC-E Edwards Analog Driver Card
3-EASC-E
Edwards (Single) Analogue driver controller module
3-EADC-E
Edwards (Dual) Analogue driver controller module
Power Supplies
3-PPS/M-230-E
Primary Power Supply 230V
3-BPS/M-230-E
Booster Power Supply 230V
3-BBC/M-230-E
Booster, Battery Charger Power Supply 230V
3-PSMON-E
Primary Power Supply Monitor
3-BPMON-E
Booster Power Supply Monitor
3-BBCMON-E
Booster, Battery Charger Monitor
3-CPU3 Central Processor Unit
3-CPU3-E
Central Processor Unit
3-LDSM Annunciator strip support module
3-LDSM-E
Annunciator strip support module
3-IDC 8/4 Initiating Device Circuits/NACS
3-IDC 8/4-E
Initiating Device Circuits/NACS
3-LCD
EST3 Main Display LCD, user interface
3-LCD-E EST3 Main Display LCD, user interface
20 Oct 2014
79
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
3-LRMF Local Rail Module Filler
3-RS485A
Data Communication, Class A
3-RS485A-E
Data Communication, Class A
3-RS485B
Data Communication, Class B
3-RS485B-E
Data Communication, Class B
3-RS232 Serial Communications Card (Printer, etc)
3-RS232-E
Serial Communications Card (Printer, etc)
EFM-2
Data Communications Filter - 2 Circuits
EFM-10 Data Communications Filter - 10 Circuits
Cabinets & Door Assemblies
3-CAB7B-E
Cabinet Back Box 3-CAB7B-E
3-CAB14B-E
Cabinet Back Box 3-CAB14B-E
3-CAB21B-E
Cabinet Back Box 3-CAB21B-E
Lobby Cabinet Assemblies
XLS-CAB7D(R)-E XLS-CAB7D-E Door Assembly - (R) indicates red
XLS-CAB14D(R)-E XLS-CAB14D-E Door Assembly - (R) indicates red
XLS-CAB21D(R)-E XLS-CAB21D-E Door Assembly - (R) indicates red
Battery Cabinets
XLS-RCC7R-E
XLS - CAB 7 Module Chassis - Remote Closet Cabinet
XLS-RCC14R-E
XLS - CAB 14 Module Chassis - Remote Closet Cabinet
XLS-RCC21R-E
XLS - CAB 21 Module Chassis - Remote Closet Cabinet
3-BTSEN-E
Remote battery cabinet interlace, temperature sensing
XLS BC-1 Battery Cabinet
3-TAMP Cabinet Tamper Switch for 3-CAB7/14/21
3-TAMPRCC
Tamper Switch for 3-RCC Cabinet
Audio & Telephone Common Controls - Chassis Assemblies
3-CHAS7 EST3 - CHASSIS 7 Module - Chassis Assy for 7 LRMs
3-CHAS7-E
EST3 - CHASSIS 7 Module - Chassis Assy for 7 LRMs
3-CHASS4
EST3 -CHASSIS 4 Mod - Chassis Assy for REMIC & 4 LRMs
3-CHASS4-E
EST3 -CHASSIS 4 Mod - Chassis Assy for REMIC & 4 LRMs
3-ASU-E Audio Source Unit with a 3-Chassis - European
3-ASU/4-E
Audio Source Unit with 4 LRM slots - European
3-ASUMX/100
100 minute extended audio memory card
3-ASU/FT-EN
Audio Source Unit with Fire Fighter Tele - European
3-FTCU-E
Firefighter Telephone Control Unit
3-ZA20A 20 watt Zone Amplifier, Class A
3-ZA20A-E
20 watt Zone Amplifier, Class A
3-ZA20B 20 watt Zone Amplifier, Class B
3-ZA20B-E
20 watt Zone Amplifier, Class B
3-ZA40A 40 watt Zone Amplifier, Class A
3-ZA40A-E
40 watt Zone Amplifier, Class A
3-ZA40B 40 watt Zone Amplifier, Class B
3-ZA40B-E
40 watt Zone Amplifier, Class B
3-BATS Battery Shelf for Single 65AH Cell
3-CBLKIT1
EST3 Extended Rail Cable Kit
3-CPUDR EST3 CPU Door Kit
Certified with the following options with requirements from EN 54-2
7.8
7.13
8.3
10
Output to fire alarm devices
Alarm counter
Fault Signals from points
Test condition
Certified with the following options with requirements from EN 54-16
XLS1000
80
7.3
Audible warning
7.4
Delay(s) to entering the voice alarm condition
7.5
Phased evacuation
7.6.2
Manual silencing of the voice alarm condition
7.7.2
Manual reset of the voice alarm condition
7.9
Voice alarm condition output
8.4
Indication of faults related to voice alarm zones
9
Disablement condition
10
Voice alarm manual control
12
Emergency microphone(s)
13.14
Redundant power amplifier
Control and indicating equipment
262z/01
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating as modular units:
XLS1000
3-SSDC1-E
Signature (Single), driver controller module
3-SDDC1-E
Signature (Dual), driver controller module
3-AADC1-E
System Sensor driver control module
3-EASC-E
Edwards (Single) Analogue driver controller module
3-EADC-E
Edwards (Dual) Analogue driver controller module
3-PPS/M-230-E
Primary Power Supply
3-BPS/M-230-E
Booster Power Supply
3-BBC/M-230-E
Booster Battery Charger Power Supply
3-ASU
Audio Source Unit
3-ASU/FT-E
Audio Source Unit with Fire Fighter Telephone
3-ASUMX/100
100 minute extended audio memory card
3ASU/4 Audio Source Unit with 4 Local Rail Modules (LRM) slots
3-ZA20A 20 watt Zone Amplifier, Class A
3-ZA20B 20 watt Zone Amplifier, Class B
3-ZA40A 40 watt Zone Amplifier, Class A
3-ZA40B 40 watts Zone Amplifier, Class B
3-CPU3 Central Processor Unit
EFM-2
Data Communications Filter
3-ZA95 95 watt Zone Amplifier, Class A
3-CAB7-E
7 Slot Cabinet
3-CAB14-E
14 Slot Cabinet
3-CAB21-E
21 Slot Cabinet
3-CAB7D(R)-E
Door for 7 Slot Cabinet, (R) indicates red
3-CAB14D(R)-E
Door for 14 Slot Cabinet, (R) indicates red
3-CAB21D(R)-E
Door for 21 Slot Cabinet, (R) indicates red
3-RCC7R-E
Small Remote Battery Cabinet
3-RCC14R-E
Medium Remote Battery Cabinet
3-RCC21R-E
Large Remote Battery Cabinet
3-LCD
Liquid Crystal Display, user interface
3-BATSEN-E
Remote battery cabinet interface, temperature sensing
3-BATSEN
Remote battery cabinet interface
3-BATS Battery Shelf
3-RS485A
Data Communication, Class A
3-RS485B
Data Communication, Class B
3-RS232 Serial Communications Card (Printer, etc)
3-PSMON
Primary Power Supply Monitor
3-IDC8/4 Initiating Device Circuits/NACS
3-24R
24, Red
3-24Y
24, Yellow
3-24G
24, Green
3-12RY Red-over-yellow pairs
3-12SR 12 Switches. Red
3-12SY 12 Switches. Yellow
3-12SG 12 Switches. Green
3-12/S1GY
12 Switches. Green over-yellow pairs
3-12/S1RY
12 Switches. Red over-yellow pairs
3-12/S2Y 24, Yellow, 12 Switches
3-12/S2R 24, Red, 12 Switches
3-6/3S1G2Y
Green-over-yellow-over-yellow triads, 6 triads
3-6/3S1GYR
Green-over-yellow-over-red triads, 6 triads
3-6/3S2RY
Red-over-yellow-over-red triads, 6 triads
3-BBCMON
Booster, Battery Charger Monitor
3-BPSMON
Booster Power supply Monitor
3-LDSM Annunciator strip support module
3-LRMF Local Rail Module Filler
3-FTCU MB
Fire fighter Telephone Control Unit MB
3-FTCU-E
Fire fighter Telephone Control Unit Display
3-REMICP
Remote Microphone, Panel
3-RCIC ASU Interconnect power and rail communication unit
Repeater
262z/01R
Incorporating as modular units:
3-RS485BA
Remote Annunciator RS485 Communications.
3-ANNCPU3
Remote Annunciator CPU
3-LCDANN-E
LCD Display and User Interface for Remote Annunciator
3-ANNSM
Remote (repeater) Annunciator Support Module
3-REMICA
Remote paging Microphone
3-24Y
24, Yellow
20 Oct 2014
81
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
3-12/S1GY
12 Switches. Green over-yellow pairs
3-6ANN-E(R)
Remote Annunciator Back Box, 6 slots, with Door (R) indicates red
3-10ANN-E(R)
Remote Annunciator Back Box, 10 slots, with Door (R) indicates red
Certified with the following options with requirements from EN 54 Part 2:
7.8
7.13
8.3
10
Output to fire alarm devices
Alarm counter
Fault Signals from points
Test condition
Notes:
1. Scope of approval does not include system compatibility.
Kentec Electronics Limited
Units 25-27, Fawkes Avenue, Questor, Dartford, Kent DA1 1JQ, United Kingdom
Tel: +44 (0)1322 222121 • Fax: +44 (0)1322 291794
E-mail: [email protected] • Website: www.kentec.co.uk
Certificate No: 360a to EN 54-4:1997+A1:2002+A2:2006
Power Supply Equipment
Certificated Products
K25800 03
10.25 A Power supply with maximum 8Ah Batteries
LPCB Ref.
No.
360a/01
KD25800 03
Incorporating the following units:
S408 Power supply module
S584 Power supply LED indication PCB
Dual O/P 10.25 A Power supply with maximum 8Ah Batteries
360a/02
Incorporating the following units:
K25800 15
S408 Power supply module
S584 Power supply LED indication PCB
S789 Dual output PCB
10.25 A Power supply with maximum 45Ah Batteries
360a/03
KD25800 15
Incorporating the following units:
S408 Power supply module
S584 Power supply LED indication PCB
Dual O/P 10.25 A Power supply with maximum 45Ah Batteries
360a/04
K25800 M3
Incorporating the following units:
S408 Power supply module
S584 Power supply LED indication PCB
S789 Dual output PCB
10.25 A Power supply with maximum 18Ah Batteries in M3
housing
360a/05
KD25800 M3
Incorporating the following units:
S408 Power supply module
S584 Power supply LED indication PCB
Dual O/P 10.25 A Power supply with maximum 18Ah Batteries
360a/06
K25800 D3
Incorporating the following units:
S408 Power supply module
S584 Power supply LED indication PCB
S789 Dual output PCB
10.25 A Power supply with maximum 45Ah Batteries in D3 housing
360a/07
Incorporating the following units:
S408 Power supply module
S584 Power supply LED indication PCB
82
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
KD25800 D3
Dual O/P 10.25 A Power supply with maximum 18Ah Batteries in D3 housing
LPCB Ref.
No.
360a/08
Incorporating the following units:
S408 Power supply module
S584 Power supply LED indication PCB
S789 Dual output PCB
Mavili Elektronik Ticaret Ve Sanayi A.S.
Bostanci Dudullu Yolu, Kutup Sok, No. 29 Y Dudullu - Umraniye, Istanbul TR 34775, Turkey
Tel: +90 216 4664 505 • Fax: +90 216 4664 510
E-mail: [email protected] • Website: www.mavigard.com
Certificate No: 926d to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
ML-1231.EN
Maxlogic intelligent analogue addressable 1 Loop, 127 addressable devices, 64 Zone
control and indicating equipment.
LPCB Ref.
No.
926d/01
Incorporating the following units:
MLY-1202.EN
Main MCU module
MLY-1203
Zone LED module
MLY-1200
SLCU module
MLY-0500-EN
PSU unit
ML-1201 Optional Network module
542.188 Optional Turkish text membrane
542.189 Optional English text membrane
542.190 Optional Russian text membrane
Certified with the following options with requirements from EN 54-2:1997
ML-1241.P.EN
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment
7.11
Delays to the auctioning of outputs fire alarm devices and fire routing
equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.12.2
Dependencies on more than one alarm signal - Type B
7.12.3
Dependencies on more than one alarm signal - Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality.
2. This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN54-13.
Maxlogic intelligent analogue addressable 1 Loop, 127addressable devices, 64 Zone
control and indicating equipment with printer
926d/01
Incorporating the following units:
MLY-1202.EN
Main MCU module
MLY-1203
Zone LED module
MLY-1200
SLCU module
MLY-0500-EN
PSU unit
ML-1203 Printer module
ML-1201 Optional Network module
542.188 Optional Turkish text membrane
542.189 Optional English text membrane
542.190 Optional Russian text membrane
Certified with the following options with requirements from EN 54-2:1997
7.8
20 Oct 2014
Output to fire alarm device(s)
83
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.9.1
7.11
ML-1232.EN
Output to fire alarm routing equipment
Delays to the auctioning of outputs fire alarm devices and
fire routing equipment
Dependencies on more than one alarm signal - Type A
Dependencies on more than one alarm signal - Type B
Dependencies on more than one alarm signal - Type C
Alarm counter
Fault signals from points
Disablement of each address point
Test condition
7.12.1
7.12.2
7.12.3
7.13
8.3
9.5
10
Notes:
1. Scope of approval does not include the operation of the network functionality.
2. This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN54-13.
Maxlogic intelligent analogue addressable 2 Loop, 254 addressable devices, 64 Zone
control and indicating equipment
926d/02
Incorporating the following units:
MLY-1202.EN
Main MCU module
MLY-1203
Zone LED module
MLY-1200
SLCU module
MLY- 0500-EN
PSU unit
ML-1201 Optional Network module
542.188 Optional Turkish text membrane
542.189 Optional English text membrane
542.190 Optional Russian text membrane
Certified with the following options with requirements from EN 54-2:1997
7.8
7.9.1
7.11
ML-1242.P.EN
Output to fire alarm device(s)
Output to fire alarm routing equipment
Delays to the auctioning of outputs fire alarm devices and
fire routing equipment
Dependencies on more than one alarm signal - Type A
Dependencies on more than one alarm signal - Type B
Dependencies on more than one alarm signal - Type C
Alarm counter
Fault signals from points
Disablement of each address point
Test condition
7.12.1
7.12.2
7.12.3
7.13
8.3
9.5
10
Notes:
1. Scope of approval does not include the operation of the network functionality.
2. This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN54-13.
Maxlogic intelligent analogue addressable 2 Loop, 254 addressable devices, 64 Zone
control and indicating equipment with printer.
926d/02
Incorporating the following units:
MLY-1202.EN
Main MCU module
MLY-1203
Zone LED module
MLY-1200
SLCU module
MLY- 0500-EN
PSU unit
ML-1203 Printer module
ML-1201 Optional Network module
542.188 Optional Turkish text membrane
542.189 Optional English text membrane
542.190 Optional Russian text membrane
Certified with the following options with requirements from EN 54-2:1997
7.8
7.9.1
7.11
7.12.1
7.12.2
7.12.3
7.13
84
Output to fire alarm device(s)
Output to fire alarm routing equipment
Delays to the auctioning of outputs fire alarm devices and
fire routing equipment
Dependencies on more than one alarm signal - Type A
Dependencies on more than one alarm signal - Type B
Dependencies on more than one alarm signal - Type C
Alarm counter
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
ML-1233.EN
LPCB Ref.
No.
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality.
2. This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN54-13.
Maxlogic intelligent analogue addressable 3 Loop, 381 addressable devices, 64 Zone
control and indicating equipment.
926d/03
Incorporating the following units:
MLY-1202.EN
Main MCU module
MLY-1203
Zone LED module
MLY-1200
SLCU module
MLY- 0500-EN
PSU unit
ML-1201 Optional Network module
542.188 Optional Turkish text membrane
542.189 Optional English text membrane
542.190 Optional Russian text membrane
Certified with the following options with requirements from EN 54-2:1997
7.8
7.9.1
7.11
ML-1234.EN
Output to fire alarm device(s)
Output to fire alarm routing equipment
Delays to the auctioning of outputs fire alarm devices and
fire routing equipment
Dependencies on more than one alarm signal - Type A
Dependencies on more than one alarm signal - Type B
Dependencies on more than one alarm signal - Type C
Alarm counter
Fault signals from points
Disablement of each address point
Test condition
7.12.1
7.12.2
7.12.3
7.13
8.3
9.5
10
Notes:
1. Scope of approval does not include the operation of the network functionality.
2. This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN54-13.
Maxlogic intelligent analogue addressable 4 Loop, 508 addressable devices, 64 Zone
CIE
926d/03
Incorporating the following units:
MLY-1202.EN
Main MCU module
MLY-1203
Zone LED module
MLY-1200
SLCU module
MLY- 0500-EN
PSU unit
ML-1201 Optional Network module
542.188 Optional Turkish text membrane
542.189 Optional English text membrane
542.190 Optional Russian text membrane
Certified with the following options with requirements from EN 54-2:1997
7.8
7.9.1
7.11
ML-1243.P.EN
20 Oct 2014
Output to fire alarm device(s)
Output to fire alarm routing equipment
Delays to the auctioning of outputs fire alarm devices and
fire routing equipment
Dependencies on more than one alarm signal - Type A
Dependencies on more than one alarm signal - Type B
Dependencies on more than one alarm signal - Type C
Alarm counter
Fault signals from points
Disablement of each address point
Test condition
7.12.1
7.12.2
7.12.3
7.13
8.3
9.5
10
Notes:
1. Scope of approval does not include the operation of the network functionality.
2. This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN54-13.
Maxlogic intelligent analogue addressable 3 Loop, 381 addressable devices, 64 Zone
926d/03
85
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
control and indicating equipment with printer.
Incorporating the following units:
MLY-1202.EN
Main MCU module
MLY-1203
Zone LED module
MLY-1200
SLCU module
MLY- 0500-EN
PSU unit
ML-1203 Printer module
ML-1201 Optional Network module
542.188 Optional Turkish text membrane
542.189 Optional English text membrane
542.190 Optional Russian text membrane
Certified with the following options with requirements from EN 54-2:1997
7.8
7.9.1
7.11
ML-1244.P.EN
Output to fire alarm device(s)
Output to fire alarm routing equipment
Delays to the auctioning of outputs fire alarm devices and
fire routing equipment
Dependencies on more than one alarm signal - Type A
Dependencies on more than one alarm signal - Type B
Dependencies on more than one alarm signal - Type C
Alarm counter
Fault signals from points
Disablement of each address point
Test condition
7.12.1
7.12.2
7.12.3
7.13
8.3
9.5
10
Notes:
1. Scope of approval does not include the operation of the network functionality.
2. This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN54-13.
Maxlogic intelligent analogue addressable 4 Loop, 508 addressable devices, 64 Zone
control and indicating equipment with printer.
926d/04
Incorporating the following units:
MLY-1202.EN
Main MCU module
MLY-1203
Zone LED module
MLY-1200
SLCU module
MLY- 0500-EN
PSU unit
ML-1203 Printer module
ML-1201 Optional Network module
542.188 Optional Turkish text membrane
542.189 Optional English text membrane
542.190 Optional Russian text membrane
Certified with the following options with requirements from EN 54-2:1997
7.8
7.9.1
7.11
Ml-22102
Output to fire alarm device(s)
Output to fire alarm routing equipment
Delays to the auctioning of outputs fire alarm devices and
fire routing equipment
Dependencies on more than one alarm signal - Type A
Dependencies on more than one alarm signal - Type B
Dependencies on more than one alarm signal - Type C
Alarm counter
Fault signals from points
Disablement of each address point
Test condition
7.12.1
7.12.2
7.12.3
7.13
8.3
9.5
10
Notes:
1. Scope of approval does not include the operation of the network functionality.
2. This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN54-13.
Maxlogic Two Zone Conventional Control and Indicating Equipment
Incorporating the units:
ML-221XX_V1.1 / ML-22102 Main Board Module
MLY-0511_V1 / MLY-0511
Power Supply Board
and as optional modules:
542.212 / ML-22102
542.211 / ML-22102
86
926d/05
English text membrane
Turkish text membrane
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
Ml-22104
LPCB Ref.
No.
542.213 / ML-22102
Russian text membrane
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices
Maxlogic Four Zone Conventional Control and Indicating Equipment
Incorporating the units:
ML-221XX_V1.1 / ML-22104 Main Board Module
MLY-0511_V1 / MLY-0511
Power Supply Board
and as optional modules:
542.215 / ML-22104
542.214 / ML-22104
542.216 / ML-22104
Ml-22108
Ml-22116
926d/06
English text membrane
Turkish text membrane
Russian text membrane
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices
Maxlogic Eight Zone Conventional Control and Indicating Equipment
Incorporating the units:
ML-221XX_V1.1 / ML-22108 Main Board Module
MLY-0511_V1 / MLY-0511
Power Supply Board
and as optional modules:
542.218 / ML-22108
English text membrane
542.217 / ML-22108
Turkish text membrane
542.219 / ML-22108
Russian text membrane
Maxlogic Sixteen Zone Conventional Control and Indicating Equipment
Incorporating the units:
ML-221XX_V1.1 / ML-22116
ML_Zone_Extand_V1 / ML-22116
MLY-0511_V1 / MLY-0511
Main Board Module
Expansion Board Module
Power Supply Board
and as optional modules:
542.221 / ML-22116
542.220 / ML-22116
542.222 / ML-22116
English text membrane
Turkish text membrane
Russian text membrane
926d/07
926d/08
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices
Morley-IAS Fire Systems By Honeywell
Honeywell Fire Systems, BSEL Tech Park, Floor 6,Sector 30A, Opposite Vshi Station, Vashi, New Mumbai,
India
Tel: +91 022 67122427 • Fax: +91 022 67122422
E-mail: [email protected] • Website: www.myhoneywell.com
Certificate No: 550g-(cl-1) to EN54-2:1997+A1:2006 and EN54-4:1997+A1:2002+A2:2006
Control and indicating equipment
Certificated Products
DXc1-S
DXc1-M
20 Oct 2014
Single loop control and indicating equipment
714-001-111 PANEL DXc1-S SINGLE LOOP REGION 1 (UK & Iceland)
714-001-112 PANEL DXc1-S SINGLE LOOP REGION 2 (Iberia, India & ME)
714-001-113 PANEL DXc1-S SINGLE LOOP REGION 3 (Dutch, French, Italian,
Slovenian)
Incorporating as modular units:
124-410-001 Base PCB 1 Loop
124-411 Display PCB
010-115 PSU RS-50-24
Single loop control and indicating equipment
714-001-111 PANEL DXc1-M SINGLE LOOP REGION 1 (UK & Iceland)
714-001-112 PANEL DXc1-M SINGLE LOOP REGION 2 (Iberia, India & ME)
714-001-113 PANEL DXc1-M SINGLE LOOP REGION 3 (Dutch, French,
Italian, Slovenian)
714-001-114 PANEL DXc1-M SINGLE LOOP REGION 4 (German)
Incorporating as modular units:
LPCB Ref.
No.
550g/01
550g/02
87
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
DXc2-M
DXc4-M
LPCB Ref.
No.
124-410-001 Base PCB 1 Loop
124-411 Display PCB
010-115 PSU RS-50-24
Two loop control and indicating equipment
714-001-221 PANEL DXc2-M TWO LOOP REGION 1 (UK & Iceland)
714-001-222 PANEL DXc2-M TWO LOOP REGION 2 (Iberia, India & ME)
714-001-223 PANEL DXc2-M TWO LOOP REGION 3 (Dutch, French, Italian, Slovenian)
Incorporating as modular units:
124-410 Base PCB 2 Loop
124-411 Display PCB
010-116 PSU RS-100-24
Four loop control and indicating equipment
714-001-241 PANEL DXc4-M FOUR LOOP REGION 1 (UK & Iceland)
714-001-242 PANEL DXc4-M FOUR LOOP REGION 2 (Iberia, India & ME)
714-001-243 PANEL DXc4-M FOUR LOOP REGION 3 (Dutch, French, Italian,
Slovenian)
Incorporating as modular units:
124-410 Base PCB 2 Loop
124-411 Display PCB
124-417 2 Loop PCB
010-116 PSU RS-100-24
Incorporating as optional modular units:
795-099 KIT DXc NETWORK CARD
795-102 KIT DXc 40 ZONE LED CARD
795-103 KIT DXc 80 ZONE LED CARD WITH COVER
795-111 KIT DXc 2 LOOP EXPANSION CARD (Applicable to the two loop CIE only)
795-117 KIT DXc PERFORMANCE CARD
795-118 KIT DXc KEYSWITCH
795-122 KIT DXc RS232
795-123 KIT DXc RS485
795-124 KIT DXc 80 ZONE LED CARD
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm devices
7.11 Delays to outputs
7.12.3 Dependencies on more than one alarm signal-Type C
7.13 Alarm counter
8.3 Fault signals from points
9.5 Disablement of each addressable point
10 Test condition
550g/03
550g/04
Notes:
1. This product approval does not constitute compliance with the fire
detection and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network
functionality.
Morley-IAS Fire Systems by Honeywell (Pittway Systems Technology Group (Europe)
Ltd)
Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom
Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888
E-mail: [email protected] • Website: www.morley-ias.co.uk
Certificate No: 429c to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
ZX1Se
1 loop analogue addressable control and indicating equipment
LPCB Ref.
No.
429c/04
722-001-301
1 loop multi-protocol control panel, language group M100
722-001-302
1 loop multi-protocol control panel, language group M200
722-002-301
1 loop multi-protocol control panel, language group M100,
Stainless Steel
722-101-301
1 loop multi-protocol control panel, language group H100
722-101-302
1 loop multi-protocol control panel, language group H200
Incorporating the following units:
88
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
795-072-100
795-068-100
795-058-105
795-066-100
795-044-001
795-004-001
795-005
124-206
124-209-005
124-370
PS82-2-NFR
ZX2Se
Morley-IAS Loop Driver Card
System Sensor Loop Driver Card
Hochiki Loop Driver Card
Apollo XP95 / Discovery Loop Driver Card
Nittan Loop Driver Card
RS 485 Communication Module
RS232 Communication Module
Processor Card
1 Loop Base Card
4 Line Display Card
2A PSU
Certified with the following options with requirements from EN 54-2:7.8
Output to fire alarm devices
7.11
Delays to outputs
7.12.3
Dependency on more than one alarm signal: Type C
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
1-2 loop analogue addressable control and indicating equipment
429c/05
720-001-301
720-001-302
720-002-301
1-2 loop multi-protocol control panel, language group M100
1-2 loop multi-protocol control panel, language group M200
1-2 loop multi-protocol control panel, language group M100,
Stainless Steel
720-101-301
1-2 loop multi-protocol control panel, language group H100
720-101-302
1-2 loop multi-protocol control panel, language group H200
Incorporating the following units:
795-072-100
795-068-100
795-058-105
795-066-100
795-044-001
795-004-001
795-005
124-206
124-209-004
124-370 4
PS82-2-NFR
ZX5Se
Morley-IAS Loop Driver Card
System Sensor Loop Driver Card
Hochiki Loop Driver Card
Apollo XP95 / Discovery Loop Driver Card
Nittan Loop Driver Card
RS 485 Communication Module
RS232 Communication Module
Processor Card
2 Loop Base Card
Line Display Card
2A PSU
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
7.12.3
Dependency on more than one alarm signal: Type C
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
1-5 loop analogue addressable control and indicating equipment
429c/06
721-001-301
721-001-302
721-002-301
1-5 loop multi-protocol control panel, language group M100
1-5 loop multi-protocol control panel, language group M200
1-5 loop multi-protocol control panel, language group M100,
Stainless Steel
721-101-301
1-5 loop multi-protocol control panel, language group H100
721-101-302
1-5 loop multi-protocol control panel, language group H200
Incorporating the following units:
795-072-100
795-068-100
795-058-105
795-066-100
795-044-001
795-004-001
795-005
795-077-020
795-077-060
795-051-001
124-206
124-403
124-370 4
PS196-4-NFR
20 Oct 2014
Morley-IAS Loop Driver Card
System Sensor Loop Driver Card
Hochiki Loop Driver Card
Apollo XP95 / Discovery Loop Driver Card
Nittan Loop Driver Card
RS 485 Communication Module
RS232 Communication Module
20 Zone LED Display Indicator Card
60 Zone LED Display Indicator Card
Internal Printer Module
Processor Card
5 Loop Base Card
Line Display Card
PSU
89
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
HRZ2-8e 2 Zone
HRZ2-8e 4 Zone
HRZ2-8e 8 Zone
DXc1-S
DXc2-M
DXc4-M
LPCB Ref.
No.
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
7.12.3
Dependency on more than one alarm signal: Type C
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
002-479-122 Language region 1, English manual
002-479-222 Language region 2
002-479-322 Language region 3, dual relay
002-492-222 Language region 2, English manual, dual relay
002-506-222 Language region 2, English manual
002-479-142 Language region 1, English manual
002-479-242 Language region 2
002-479-342 Language region 3, dual relay
002-492-242 Language region 2, English manual, dual relay
002-506-242 Language region 2, English manual
002-479-182 Language region 1, English manual
002-479-282 Language region 2
002-479-382 Language region 3, dual relay
002-492-282 Language region 2, English user manual, dual relay
002-506-282 Language region 2, English user manual
Incorporating the following units:
020-747 8-way relay kit
020-772 4-way monitored sounder kit
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Output to automatic fire protection equipment: Type A
7.10.3
Output to automatic fire protection equipment: Type C
7.10.4
Fault monitoring of fire protection equipment
7.11.1
Delays to outputs
7.11.2
Manual or automatic switching of delays to outputs
7.12.2
Dependency on more than one alarm signal: Type B
8.9
Output to fault warning routing equipment
10
Test condition
Single loop control and indicating equipment
714-001-111
PANEL DXc1-S SINGLE LOOP REGION 1 (UK & Iceland)
714-001-112
PANEL DXc1-S SINGLE LOOP REGION 2 (Iberia, India & ME)
714-001-113
PANEL DXc1-S SINGLE LOOP REGION 3
(Dutch, French, Italian, Slovenian)
Incorporating as modular units:
124-410-001
Base PCB 1 Loop
124-411 Display PCB
010-115 PSU RS-50-24
Two loop control and indicating equipment
714-001-221
PANEL DXc2-M TWO LOOP REGION 1 (UK & Iceland)
714-001-222
PANEL DXc2-M TWO LOOP REGION 2 (Iberia, India & ME)
714-001-223
PANEL DXc2-M TWO LOOP REGION 3
(Dutch, French, Italian, Slovenian)
Incorporating as modular units:
124-410 Base PCB 2 Loop
124-411 Display PCB
010-116 PSU RS-100-24
Four loop control and indicating equipment
714-001-241
PANEL DXc4-M FOUR LOOP REGION 1 (UK & Iceland)
714-001-242
PANEL DXc4-M FOUR LOOP REGION 2 (Iberia, India & ME)
714-001-243
PANEL DXc4-M FOUR LOOP REGION 3
(Dutch, French, Italian, Slovenian)
Incorporating as modular units:
124-410 Base PCB 2 Loop
124-411 Display PCB
124-417 2 Loop PCB
010-116 PSU RS-100-24
429c/10
429c/11
429c/12
429c/13
429c/14
429c/15
Incorporating as optional modular units:
795-099 KIT DXc NETWORK CARD
795-102 KIT DXc 40 ZONE LED CARD
795-103 KIT DXc 80 ZONE LED CARD WITH COVER
90
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
795-111
CIE only)
795-117
795-118
795-122
795-123
795-124
KIT DXc 2 LOOP EXPANSION CARD (Applicable to the two loop
KIT DXc PERFORMANCE CARD
KIT DXc KEYSWITCH
KIT DXc RS232
KIT DXc RS485
KIT DXc 80 ZONE LED CARD
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.11
Delays to outputs
7.12.3
Dependencies on more than one alarm signal-Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each addressable point
10
Test condition
Notes:
1.
2.
DXc1-M
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Scope of approval does not include the operation of the network functionality.
Single loop and indicating equipment
714-001-111
PANEL DXc1-S SINGLE LOOP REGION 1
Iceland)
714-001-112
PANEL DXc1-S SINGLE LOOP REGION 2
(Iberia, India & ME)
714-001-113
PANEL DXc1-S SINGLE LOOP REGION 3
(Dutch, French, Italian, Slovenian)
714-001-114
PANEL DXc1-S SINGLE LOOP REGION 4
(German)
429c/16
(UK &
Incorporating as modular units:
124-410-001
Base PCB 1 Loop
124-411 Display PCB
010-115 PSU RS-50-24
Multron Systems Pte Ltd
217 Kallang Bahru, Multron Building, Singapore 339 347, Singapore
Tel: +65 6743 2555 / 6395 6868 • Fax: +65 6743 2777 / 6395 6869
E-mail: [email protected] • Website: www.multron.com
Certificate No: 548j-(cl-6) to EN 54-2: 1997 & EN 54-4: 1997
Certificate No: 548p-(cl-3) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
MPC-101
Single zone conventional control and indicating equipment
LPCB Ref.
No.
548j/02
MPC-102
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
10
Test condition
Two zone conventional control and indicating equipment
548j/03
MPC-104
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
10
Test condition
Four zone conventional control and indicating equipment
548j/04
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
20 Oct 2014
91
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
MPC-108
10
Test condition
Eight zone conventional control and indicating equipment
548j/05
MPC-116
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
10
Test condition
Sixteen zone conventional control and indicating equipment
548j/06
IFP2
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
10
Test condition
Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment
548p/01
Incorporating the following units:
MB-220/ F7.820.826
SB-220/ F7.820.827
TB-220/ F7.820.828
PS-220/ F7.820.829b
ZP-220/ F7.820.312d Zone
Main board
Switch board
Loop interface board
Power supply unit
indication and intervention board
Incorporating as optional modular units:
P-9930/ F7.820.913a
RS-232 board for configuration
P-9901A
Printer module kit
LC200/ F7.820.1125
Loop board (for loop expansion)
IFP8
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
7.10.1
Output to automatic Fire Protection
Equipment Type A
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
Intelligent 8 loop, 140 zone analogue addressable
control and indicating equipment
548p/02
Incorporating the following units:
SB-800/ F7.820.1238
Indication board
LCIFP8/ F7.820.1239
Loop board
PB-800/ F7.820.1311
Power board
ZP-800/ F7.820.1312
ZCP board
KB-800/ F7.820.1326
Keypad board
MB-800/ F7.820.1237
Main board
MO-800/ F7.820.1310
Mother board
Incorporating as optional modular units:
P-9935/ F7.820.1313
USB communication board
Certified with the following options with requirements from EN 54 Part 2:
7.8
7.9.1
7.9.2
7.10.1
7.10.2
7.11
7.12.1
7.12.2
7.13
8.3
9.5
10
IFP2/1
Output to fire alarm devices
Output to fire routing equipment
Alarm confirmation input from fire routing equipment
Output type A
Output type B
Delays to outputs
Dependencies on more than one alarm signal - Type A
Dependencies on more than one alarm signal - Type B
Alarm counter
Fault signals from points
Disablement of each address point
Test condition
Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment
Incorporating the following units:
MB-220/ F7.820.826
Main board
SB-220/ F7.820.827
Switch board
TB-220/ F7.820.828
Loop interface board
PS-220/ F7.820.829b
Power supply unit
ZP-220/ F7.820.312d
Zone indication and intervention
board
548P/08
Incorporating as optional modular units:
92
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
P-9930/ F7.820.913a RS-232
P-9901A
LC200/ F7.820.1125
board for configuration
Printer module kit
Loop board (for loop expansion)
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to Fire Alarm Devices
7.10.1
Output to automatic Fire Protection
Equipment Type A
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
Nitin Ventures FZE
P.O. Box 262294, Jebel Ali Free Zone, Dubai, United Arab Emirates
Tel: +97 148865858/859 • Fax: +97 148865800
E-mail: [email protected] • Website: www.nitinfire.com
Certificate No: 018c to EN 54-2: 1997 and EN 54-4: 1997
Certificated Products
Discovery
NV 2
NV 4
NV 8
20 Oct 2014
4 loop analogue addressable control and indicating equipment
Incorporating as modular units:
A1579 Motherboard
A1580 Display board
A1585 Loop cards
A1584 230Vac power supply control card
A1599 Printer board
Certified with the following options with requirements from EN54-2: 1997
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
2 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface (option)
Certified with the following options with requirements from EN54-2: 1997
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
4 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface (option)
Certified with the following options with requirements from EN54-2: 1997:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
8 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface (option)
Certified with the following options with requirements from EN54-2: 1997:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
LPCB Ref.
No.
018c/01
018c/02
018c/03
018c/04
93
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
NV 16
NV 32
NV 8R
NV 16R
NV 32R
LPCB Ref.
No.
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
16 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface (option)
Certified with the following options with requirements from EN54-2: 1997:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
32 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1629 Display board
C1632 16 Zone expansion board
C1652 5A Power supply board
C1631 Repeater interface (option)
Certified with the following options with requirements from EN54-2: 1997:
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
8 zone conventional repeater unit
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface
16 zone conventional repeater unit
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface
32 zone conventional repeater unit
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface
018c/05
018c/06
018c/R01
018c/R02
018c/R03
Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd)
Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom
Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888
E-mail: [email protected] • Website: www.notifierfiresystems.co.uk
Certificate No: 154g to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
ID3000
ID3002
94
Basic Equipment Kit, (BEK): Modular analogue addressable control and indicating
equipment.
020-538
Basic Equipment Kit ID3000, Group 0
020-538-001
ID3000 Basic Equipment Kit, Group 1
020-538-003
ID3000 Basic Equipment Kit, Group 3
020-538-004
ID3000 Basic Equipment Kit, Group 4
020-538-005
ID3000 Basic Equipment Kit, Group 5
Fixed build 2 loop analogue addressable control and indicating equipment.
LPCB Ref.
No.
154g/01
154g/01
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
ID3004
ID3006
ID3008
LPCB Ref.
No.
002-473
ID3002, 2 Loop, PSU3A, Group 0, Red
002-474
ID3002, 2 Loop, PSU3A, Group 0
002-474-001
ID3002, 2 Loop, PSU3A, Group 1
002-474-003
ID3002, 2 Loop, PSU3A, Group 3
002-474-004
ID3002, 2 Loop, PSU3A, Group 4
002-474-005
ID3002, 2 Loop, PSU3A, Group 5
Fixed build 4 loop analogue addressable control and indicating equipment.
020-727
ID3004, 4 Loop, PSU7A, Group 0, LIB
020-728
ID3004, 4 Loop, PSU7A, Group 0, ELIB
020-729
ID3004, 4 Loop, PSU7A, Group 0, LIB, printer
020-730
ID3004, 4 Loop, PSU7A, Group 0, LIB, 64 zone LED
Fixed build 6 loop analogue addressable control and indicating equipment.
020-731
ID3006, 6 Loop, PSU7A, Group 0, 2xLIB
020-732
ID3006, 6 Loop, PSU7A, Group 0, 2xELIB
020-733
ID3006, 6 Loop, PSU7A, Group 0, 2xLIB, printer
020-734
ID3006, 6 Loop, PSU7A, Group 0, 2xLIB, 64 zone LED
Fixed build 8 loop analogue addressable control and indicating equipment.
020-735 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery Enclosure
020-736 ID3008, 8 Loop, PSU7A, Group 0, 3xELIB, 78Ah Battery Enclosure
020-737 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery Enclosure, Printer
020-738 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery enclosure, printer, 64
Zone LED
ID3000 series
154g/01
154g/01
154g/01
Incorporating the following as modular units:
Enclosures:
020-472-009
Backbox Kit Standard, Black / Grey
020-473-009
Backbox Kit Extended, Black / Grey
020-474-009
Backbox Kit Extended Deep, Black / Grey
020-475-009
Backbox Kit Double Extended, Black / Grey
020-476-009
Backbox Kit Double Extended Deep, Black / Grey
020-480-009
Cover Kit Main Moulded, Black / Grey
020-481-009
Cover Kit Extended Moulded, Black / Grey
020-508-009
Backbox Extension Standard Assembly Black / Grey
020-509-009
Backbox Extension Deep Assembly Black / Grey
020-513-009
High Security Cover Kit Main, Black / Grey
020-514-009
High Security Cover Kit Extension
020-576
Main Cover, Stainless Steel
020-577
Extension Cover Stainless Steel
020-621-256
Zone Extension Cover, Stainless / Steel
020-621-009
256 Zone Extension Cover, Black / Grey
020-541-009
PSU7A / 78Ah Battery Enclosure
Modules:
020-559-001
Zone Extension Chassis Kit 1-64 Zone C/W Display Module020-559002
Zone Extension Chassis Kit 65-128 Zone
C/W Display Module
020-612
Double Extended Chassis Kit 256 Zone
020-708-009
Extension Chassis with Printer
020-644-009
Printer Assembly
020-588
Notifier Dual Loop Interface Board, (LIB)
020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB)
020-478 RS232 Interface
020-479 RS485 Interface
020-648 PSU3A
020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)
020-548 PSU7A Status Indication
020-543 Dual Transmission Path / Booster, PSU Interface
020-773 Routing Termination Unit (DEOL)
020-877 Extinguishing Interface Module M221-SI
020-643 ID²net Fibre Optic Interface Kit
020-647 ID²net Network Gateway Module, (NGM) for use in ID3000 Panel
ID50
20 Oct 2014
Note 1:
Products are available in language variants as follows:
Group 0: English and Icelandic, with English manuals
Group 1: English, Spanish, Portuguese, Icelandic and Italian
Group 3: English, Swedish, Danish, Norwegian and Finish
Group 4: English and Polish
Group 5: English and Cyrillic
Note 2:
Fixed build products incorporate a corresponding Basic Equipment Kit.
Single loop analogue addressable control and indicating equipment
154g/02
95
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
ID60
002-455 ID50 Panel Group 0
002-455-001
ID50 Panel Group 1
002-455-003
ID50 Panel Group 3
002-455-004
ID50 Panel Group 4
May also incorporate the following optional modular unit:
002-553 RS485 Communication Kit
Single loop analogue addressable control and indicating equipment
154g/03
ID61
002-456
ID60 Panel Group 0
002-456-001
ID60 Panel Group 1
002-456-003
ID60 Panel Group 3
002-456-004
ID60 Panel Group 4
May also incorporate the following optional modular unit:
002-553 RS485 Communication Kit
Single loop analogue addressable control and indicating equipment
154g/04
ID62
NFS2-8 2 Zone
NFS2-8 4 Zone
96
002-463
ID61 Panel Group 0
002-463-001
ID61 Panel Group 1
002-463-004
ID61 Panel Group 4
002-485-001
ID61 Panel Group 1 (Red)
Incorporating the following modular unit:
020-648 PSU3A Kit
May also incorporate the following optional modular units:
020-479 RS485 Communication Kit
020-644-009
Printer Kit
Single loop analogue addressable control and indicating equipment
002-461
ID62 Panel Group 0
002-461-001
ID62 Panel Group 1
002-461-004
ID62 Panel Group 4
Incorporating the following modular unit:
020-648 PSU3A Kit
May also incorporate the following optional modular units:
020-479 RS485 Communication Kit
020-644-009
Printer Kit
Certified with the following options with requirements:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment: Type A
7.10.3
Outputs to fire protection equipment: Type C
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to Outputs
7.12.2
Dependencies on more than one alarm signal: Type B
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Note: Products are available in various language groups as follows:
Group 0: English, Icelandic, French, Italian, Portuguese and Spanish, (shipped with
English manuals)
Group 1: English, Icelandic, French, Italian, Portuguese and Spanish
Group 2: English, Dutch, German, French and Italian
Group 3: English, Swedish, Danish, Norwegian and Finnish
Group 4: English and Polish
002-477-122
Language region 1, light grey
002-477-129
Language region 1, black & grey
002-477-222
Language region 2, light grey
002-477-229
Language region 2, black & grey
002-477-322
Language region 3, light grey, dual relay
002-477-329
Language region 3, black & grey, dual relay, English manual
002-490-129
Language region 1, black & grey, dual relay, English manual
002-490-229
Language region 2, black & grey, dual relay, English manual
002-490-222
Language region 2, light grey, English manua
002-477-142
Language region 1, light grey
002-477-149
Language region 1, black & grey
002-477-242
Language region 2, light grey
002-477-249
Language region 2, black & grey
002-477-342
Language region 3, light grey, dual relay
002-477-349
Language region 3, black & grey, dual relay
154g/05
154g/06
154g/07
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
NFS2-8 8 Zone
LPCB Ref.
No.
002-490-149
002-490-249
002-490-242
002-477-182
002-477-189
002-477-282
002-477-289
002-477-382
002-477-389
002-490-189
002-490-289
002-490-282
Language region 1, black & grey, dual relay, English manual
Language region 2, black & grey, dual relay, English manual
Language region 2, light grey, English manual
Language region 1, light grey
Language region 1, black & grey
Language region 2, light grey
Language region 2, black & grey
Language region 3, light grey, dual relay
Language region 3, black & grey, dual relay
Language region 1, black & grey, dual relay, English manual
Language region 2, black & grey, dual relay, English manual
Language region 2, light grey, English manual
154g/08
Incorporating the following units:
020-747 8-Way relay kit
020-772 4-way monitored sounder kit
Certified with the following options from EN 54 Part 2:
7.8
7.9.1
ID2000
ID2002
Output to fire alarm devices
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Output to automatic fire protection equipment: Type A
7.10.3
Output to automatic fire protection equipment: Type C
7.10.4
Fault monitoring of fire protection equipment
7.11.1
Delays to outputs
7.11.2
Manual or automatic switching of delays to outputs
7.12.2
Dependency on more than one alarm signal: Type B
8.9
Output to fault warning routing equipment
10
Test condition
Basic Equipment Kit, (BEK): Modular analogue addressable control
and indicating equipment.
020-628 Basic equipment kit ID2000 Group 0,
020-628-001Basic equipment kit ID2000 Group 1, UK ES PT IT
020-628-002Basic equipment kit ID2000 Group 2, UK NL FR
Fixed build 2 loop analogue addressable control and indicating
equipment.
002-459 ID2002, 2 loop control and indicating equipment, Group 1
154g/09
154g/09
Incorporating the following as optional modular units:
Enclosures:
020-472-009
020-473-009
020-474-009
020-475-009
020-476-009
020-480-009
020-481-009
020-508-009
020-509-009
020-576
020-577
020-541-009
Modules:
020-649-009
020-708-009
020-644-009
020-588
020-478
020-479
020-648
Backbox Kit Standard, Black / Grey
Backbox Kit Extended, Black / Grey
Backbox Kit Extended Deep, Black / Grey
Backbox Kit Double Extended, Black / Grey
Backbox Kit Double Extended Deep, Black / Grey
Cover Kit Main Moulded, Black / Grey
Cover Kit Extended Moulded, Black / Grey
Backbox Extension Standard Assembly Black / Grey
Backbox Extension Deep Assembly Black / Grey
Main Cover, Stainless Steel
Extension Cover Stainless Steel
PSU7A / 78Ah Battery Enclosure
64 Zone Extension Chassis Kit 64 Zone C/W Display Module
Extension Chassis with Printer
Printer Assembly
Notifier Dual Loop Interface Board, (LIB)
RS232 Interface
RS485 Interface
PSU3A
PSU7A, (Requires Dual Transmission Path / Booster, PSU
Interface)
020-543
Dual Transmission Path / Booster, PSU Interface
020-548
PSU7A Status Indication
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.11
Delays to outputs
7.12.3
Dependency on more than one alarm signal type C
7.13
Alarm counter
20 Oct 2014
97
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
8.3
9.5
10
Fault signals from points
Disablements of addressable points
Test condition
Note:
Products are available in language variants as follows:
Group 0: English, Spanish, Portuguese and Italian (shipped with
English manuals)
Pearl
Group 1: English, Spanish, Portuguese and Italian
Group 2: English, Dutch, and French
Two loop analogue addressable control and indicating equipment
154g/10
Incorporating the following units:
124-408 3A PSU board
124-412 Network gateway module
124-421 Base board incorporating two loops
124-422 Display board
124-423 VdS I/O Module
124-426 Communications module
PRL
Box Extended Back box
Incorporating the following optional regional language text inserts:
PRL-EN ( English)
PRL-D (German)
PRL-IB
(Iberia)
PRL-BNL (Benelux)
PRL-NRD (Swedish)
PRL-MEA (Middle East and Africa)
PRL-IT (Italian)
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10.1
7.10.3
7.10.4
7.11
7.12.2
7.12.3
7.13
8.3
8.9
9.5
10
Notes:
1.
002-467
Output to fire alarm devices
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment type A
Output to fire protection equipment type C
Fault monitoring of fire protection equipment
Delays to outputs
Dependency on more than one alarm signal type B
Dependency on more than one alarm signal type C
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablements of addressable points
Test condition
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements
of EN 54-13.
2. Scope of approval does not include the operation of the network
functionality.
ID 2 net Network Gateway Unit, (NGU) Notifier Protocol
154g/NO1
Incorporating the following as modular units:
020-643 ID 2 net Fibre Optic Interface Kit
020-647 ID 2 net Network Gateway Module, (NGM) for use in ID3000 Panels
020-648 PSU3A
Certified with the following options with requirements:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Output to fire protection equipment type A
7.10.3
Output to fire protection equipment type C
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.2
Dependency on more than one alarm signal type B
7.12.3
Dependency on more than one alarm signal type C
7.13
Alarm counter
98
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
8.3
8.9
9.5
10
Fault signals from points
Output to fault warning routing equipment
Disablements of addressable points
Test condition
Olympia Electronics S.A.
Kolindros Pierias, 60061, Greece
Tel: (+30) 2353051200 • Fax: (+30 )2353051486
E-mail: [email protected] • Website: www.olympia-electronics.gr
Certificate No: 1010a to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2 006
Certificated Products
BSR-2104
Two loop analogue addressable control and indicating equipment.
LPCB Ref.
No.
1010a/01
Incorporating the following units:
1702091
Main board
0905073
Main processor board
0506073
Input / Output Unit
1603073
LED PCB board
2307103
Loop 1 incorporating power control board
DPP100-24
Lambda PSU block
BSR-2114
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.10.1
Output to fire protection equipment (Type A)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.13
Alarm counter
8.3
Fault signal from points
8.9
Output to fault warning routing equipment
9.5
Disablement of each address point
10
Test condition
Four loop analogue addressable control and indicating equipment.
1010a/02
Incorporating the following units:
1702091
Main board
0905073
Main processor board
0506073
Input / Output Unit
1603073
LED PCB board
2307103
Loop 1 incorporating power control board
2607103
Loop 2 board
DPP100-24
Lambda PSU block
Certified with the following options with requirements from EN 54 part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.10.1
Output to fire protection equipment (Type A)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.13
Alarm counter
8.3
Fault signal from points
8.9
Output to fault warning routing equipment
9.5
Disablement of each address point
10
Test condition
20 Oct 2014
99
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Orient Corporation Pte. Ltd.
Block 3018, Bedok North Street 5, #05-51, Eastlink Light Industrial Building 486132, Singapore
Tel: (+65) 6242 5489 • Fax: (+65) 6241 2291
E-mail: [email protected]
Certificate No: 176c-(cl-1) to EN 12094-1: 2003, EN54-2: 1997 + A1: 2006 + A2: 2007 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Control and indicating equipment
Certificated Products
EP203/ORIENT
Conventional three zone class A extinguisher control panel
LPCB Ref.
No.
176c/01
Incorporating the following units:
SPF0000203
SPF0000212
SPF0003613
SPF0000214
Main extinguisher control
External relay interface
Power supply unit
EP214 terminator
Incorporating as modular units:
EP210S Remote Status Unit Surface Mount optional (See Note 1)
EP211 Economy Status Unit optional (See Note 1)
Certified with the following options with requirements from EN 12094-1:2003
4.17
4.18
4.19
4.20
4.21
4.23
4.26
4.27
4.30
Delay of extinguishing signal
Signal representing the flow of extinguishing agent
Monitoring of the status of components
Emergency hold device
Control of flooding time
Manual only mode
Triggering of equipment outside the system
Emergency abort device
Activation of alarm devices with different signals
Certified with the following options with requirements from EN 54-2:1997
7.8
7.11
7.13
10
Output to fire alarm device(s)
Delays to the auctioning of outputs fire alarm devices and fire
routing equipment
Alarm counter
Test condition
Note:
1. Optional Remote Status Unit part No. EP210S & Economy Status Unit part No.
EP211
are not certified as meeting the requirements of the standards specified.
2. Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature
range of -5°C to +40°C.
100
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Pelco Finland Oy
Sokerilinnantie 11C, 02600, Espoo, Finland
Tel: +358 10 446 511 • Fax: +358 10 446 5103
E-mail: [email protected] • Website: www.pelco.com/nordic
Manufactured at:
Pelco Finland Oy, Manttaalitie 5-7, 01530 Vantaa, Finland
Certificate No: 883b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
FX
8 Loop Analogue addressable CIE
LPCB Ref.
No.
883b/01
Basic unit incorporates the following modules:
FX-MC2
FX-UI2
FX-PSB
or
FX-PSA
Master controller
User interface
4.5 A Power Supply
2.2 A Power Supply
Optional Modules -The following modules are optional additions to the basic unit:
FX-ALCB Two loop addressable controller - Apollo protocol card
FX-ALCA One loop addressable controller - Apollo protocol card
FX-LC
Two loop addressable controller - System Sensor protocol card
FX-SLC Two loop addressable controller - System Sensor advanced protocol card
FX-CLC Sixteen loop conventional Controller
FX-IOC I/O controller board
FX-OCA 16 clean output module
FX-LB80 80 Zone LED indication card
FX2-LB32
32 Panel LED indication card
FX-BAT Separate battery box (4x17Ah, 12V)
FXM-BAT Separate battery box (4x12Ah, 12V)
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.10.3
7.11
7.12.2
7.13
8.3
8.4
8.9
9.5
10
FXL
Outputs to fire alarm devices
Output to fire alarm routing equipment
Output to Fire Protection Equipment (Output Type C)
Delays to outputs
Dependencies on more than one alarm signal (Type B)
Alarm counter
Fault signals from points
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality.
2. This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13.
8 Loop Analogue addressable CIE
883b/02
Basic unit incorporates the following modules:
FX-MC2
FX-UI2
FX-PSB
or
FX-PSA
Master controller
User interface
4.5 A Power Supply
2.2 A Power Supply
Optional Modules -The following modules are optional additions to the basic unit:
FX-ALCB Two loop addressable controller - Apollo protocol card
20 Oct 2014
101
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
FX-ALCA One loop addressable controller - Apollo protocol card
FX-LC
Two loop addressable controller - System Sensor protocol card
FX-SLC Two loop addressable controller - System Sensor advanced protocol card
FX-CLC Sixteen loop conventional Controller
FX-IOC I/O controller board
FX-OCA 16 clean output module
FX-LB80 80 Zone LED indication card
FX2-LB32
32 Panel LED indication card
FX-BAT Separate battery box (4x17Ah, 12V)
FXM-BAT Separate battery box (4x12Ah, 12V)
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.10.3
7.11
7.12.2
7.13
8.3
8.4
8.9
9.5
10
FXM
Outputs to fire alarm devices
Output to fire alarm routing equipment
Output to Fire Protection Equipment (Output Type C)
Delays to outputs
Dependencies on more than one alarm signal (Type B)
Alarm counter
Fault signals from points
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality.
2. This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13.
4 Loop Analogue addressable CIE
883b/03
Basic unit incorporates the following modules:
FX-MC2
FX-UI2
FX-PSB
or
FX-PSA
Master Controller
User Interface
4.5 A Power Supply
2.2 A Power Supply
Optional Modules -The following modules are optional additions to the basic unit:
FX-ALCB Two loop addressable controller - Apollo protocol card
FX-ALCA One loop addressable controller - Apollo protocol card
FX-LC
Two loop addressable controller - System sensor protocol card
FX-SLC Two loop addressable controller - System Sensor advanced protocol card
FX-CLC Sixteen loop conventional Controller
FX-IOC I/O controller board
FX-OCA 16 clean output module
FX-LB80 80 Zone LED indication card
FX2-LB32
32 Panel LED indication card
FX-BAT Separate battery box (4x17Ah, 12V)
FXM-BAT Separate battery box (4x12Ah, 12V)
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.10.3
7.11
7.12.2
7.13
8.3
8.4
8.9
9.5
10
FXS
102
Outputs to fire alarm devices
Output to fire alarm routing equipment
Output to Fire Protection Equipment (Output Type C)
Delays to outputs
Dependencies on more than one alarm signal (Type B)
Alarm counter
Fault signals from points
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. Scope of approval does not include the operation of the network functionality.
2. This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13.
Analogue addressable Repeater Panel
883b/R01
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating the following modules:
FX-MC2
FX-UI2
Master Controller
User Interface
Optional Modules -The following modules are optional additions to the basic unit:
FX-IOC
I/O Controller
Photain Controls
8 New Market Court, Chippenham Drive, Kingston, Milton Keynes MK10 0AQ, United Kingdom
Tel: 01908 281981 • Fax: 01908 282554
E-mail: [email protected]
Certificate No: 092h to BS EN 54 - 2: 1998 and BS EN 54- 4: 1998 N.B. This certificate is to a withdrawn standard. Control and
indicating equipment conforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). This
certificate, to the withdrawn standard, is maintained because controland indicating equipment meeting the withdrawn standard
is still requested by some regulators outside of the EU
Certificate No: 1199c to EN-2:1997 + A1:2006 EN-4:1997 + A1:2002
Certificated Products
System 2000 PAI
LPCB Ref.
No.
092h/01
System 2000 PAI
Incorporating as modular units:
ZP3-MB2-4L
ZP3-MB2-2L
ZP3-MB2-1L
ZP3-CPU1
ZP3-DB1
ZP3-ZB50
ZP3-CB1
ZP3-PR1
ZP3AB-SCB-D
ZP3AB-RL8
ZP3-AB-MA8
ZP3AB-OP24
ZP3AB-MIP8
ZP3-Xl
4 Loop Main board
2 Loop Main board
1 Loop Main board
CPU board
Display board
50 Zone LED board
Commissioning key switch board
Printer Kit
Control bus driver
Programmable relay output board, 8 way
Programmable monitored output board, 8 way
Programmable transistor output board, 24 way
Programmable input board, 8 way
230Vac Power supply unit
Approved with the following options from BS EN54 Part 2:
7.8
7.9
7.10
7.11
7.12
7.13
8.3
8.4
8.9
9.5
10
11
Output to fire alarm devices
Output to fire alarm routing equipment
Output to fire protection equipment
Delays to outputs
Co-incidence detection
Alarm counter
Fault signals from points
Total loss of power
Output to fault routing equipment
Disablement of addressable points
Test condition
Standardised input/output interface
System 2000 PAI 1, 2 and 4 loop analogue addressable control and indicating equipment
Incorporating as modular units:
ZP3-MB2-4L
ZP3-MB2-2L
ZP3-MB2-1L
ZP3-CPU1
ZP3-DB1
ZP3-ZB50
20 Oct 2014
4 Loop Main board
2 Loop Main board
1 Loop Main board
CPU board
Display board
50 Zone LED board
103
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
ZP3-CB1
ZP3-PR1
ZP3AB-SCB-D
ZP3AB-RL8
ZP3-AB-MA8
ZP3AB-OP24
ZP3AB-MIP8
ZP3-Xl
Commissioning key switch board
Printer Kit
Control bus driver
Programmable relay output board, 8 way
Programmable monitored output board, 8 way
Programmable transistor output board, 24 way
Programmable input board, 8 way
230Vac Power supply unit
Approved with the following options from BS EN54 Part 2:
7.8
7.9
7.10
7.11
7.12
7.13
8.3
8.4
8.9
9.5
10
11
Output to fire alarm devices
Output to fire alarm routing equipment
Output to fire protection equipment
Delays to outputs
Co-incidence detection
Alarm counter
Fault signals from points
Total loss of power
Output to fault routing equipment
Disablement of addressable points
Test condition
Standardised input/output interface
Protec Fire Detection plc
Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom
Tel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273
E-mail: [email protected] • Website: www.protec.co.uk
Certificate No: 201ad to EN 54-2: 1997+A1: 2006 and EN 54-4: 1997+A1: 2002+A2: 2006
Certificated Products
6304
LPCB Ref.
No.
4 Loop Analogue addressable control and indicating equipment
201ad/09
Incorporating the following units:
SF41-860-52F
SF41-850-50C
SF40-877-65
31-100-22
31-243-36
62-407-57
04-701-38
SF40-465-43F
SF41-913-56B
31-275-44
SF40-879-67G
Main Board
Terminal Board
CP250 Printer Board
Backbox
Inner Plate
Door
Printer Mechanism
Series 9000 Power Supply Unit
SMT Dual 6000 Loop Card
Optional external 24 AH battery box
Network Card
Certified with the following options with requirements from EN 54: Part 2:
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment
7.11
Delays to outputs
7.12.3
Dependencies on more than one alarm signal Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Note:
1. Scope of approval does not include the operation of the network functionality.
6400/DCN
Display and Control node
201ad/01
Incorporating the following units:
104
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
SF40-855-65E
SF40-811-47E
SF40-821-49E
Display control unit
Local display unit
PF Terminal unit
Certified with the following options with requirements from EN 54: Part 2:
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment
7.11
Delays to outputs
7.12.3
Dependencies on more than one alarm signal - Type C
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of each address point
10
Test condition
Notes:
1.
2.
6400/2LPN
This unit does not meet the requirements of EN 54-2 & 4
as a stand alone unit. It is intended for use as part of the 6400
distributed network fire alarm system. In order to meet the
requirements of
EN 54-2 & 4 the unit must be used in conjunction with the
following units:

6400/2LPN 2 Loop processing node and/or 6400/4LPN 4 Loop
processing node

6400/PSU 8A Power supply with charger
Scope of approval does not include the operation of the network functionality.
2 Loop processing node
201ad/02
Incorporating the following units:
SF40-812-48E
SSU
SF40-814-50E
Local IO
SF40-817-53C
Terminal board
SF40-819-55D
6400 Loop terminal board
SF40-818-54
LPN display board
SF40-826-54C
6400 OPTO isolated 485 board
SF40-913-56B
6400 Loop Transmission board
Notes:
1. This unit does not meet the requirements of EN 54-2
& 4 as a stand alone unit. It is intended for use as
part of the 6400 distributed network fire alarm
system. In order to meet the requirements of EN 542 & 4 the unit must be used in conjunction with the
following units:
 6400/DCN Display and Control node
 6400/PSU 8A Power supply with charger
2. Scope of approval does not include the operation of the network functionality.
6400/4LPN
4 Loop processing node
201ad/03
Incorporating the following units:
SF40-812-48E
SSU
SF40-814-50E
Local IO
SF40-817-53C
5400 Terminal board
SF40-819-55D
6400 Loop terminal board
SF40-818-54
LPN display board
SF40-826-54C
6400 OPTO 485 board
SF40-913-56B
6400 Loop Transmission board
Notes:
1. This unit does not meet the requirements of EN
54-2 & 4 as a stand alone unit. It is intended for
use as part of the 6400 distributed network fire
alarm system. In order to meet the requirements
of EN 54-2 & 4 the unit must be used in
conjunction with the following units:

6400/DCN Display and Control node

6400/PSU 8A Power supply with charger
2. Scope of approval does not include the operation of the network functionality.
6400/DCN/2LPN
20 Oct 2014
Display and control node plus 2 Loop processing node
201ad/04
105
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating the following units:
SF40-855-65E
SF40-811-47E
SF40-812-48E
SF40-814-50E
SF40-817-53C
SF40-819-55D
SF40-826-54C
SF40-913-56B
Display control unit
5400 LED display unit
SSU
Local IO
5400 Terminal board
6400 Loop terminal board
6400 OPTO isolated 485 board
6400 Loop Transmission board
Certified with the following options with requirements from EN 54: Part 2:
7.8
7.9.1
7.11
7.12.3
7.13
8.3
8.9
9.5
10
Notes:
1.
2.
6400/DCN/4LPN
Output to fire alarm device(s)
Output to fire alarm routing equipment
Delays to outputs
Dependencies on more than one alarm signal - Type C
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablement of each address point
Test condition
This unit does not meet the requirements of EN
54-2 & 4 as a stand alone unit. It is intended for
use as part of the 6400 distributed network fire
alarm system. In order to meet the requirements
of EN 54-2 & 4 the unit must be used in
conjunction with the following units:

6400/PSU 8A Power supply with charger
Scope of approval does not include the operation of the network functionality.
Display and control node plus 4 Loop processing node
201ad/05
Incorporating the following units:
SF40-855-65E
SF40-811-47E
SF40-812-48E
SF40-814-50E
SF40-817-53C
SF40-819-55D
SF40-826-54C
SF40-913-56B
Display control unit
5400 Local display unit
SSU
Local IO
5400 Terminal board
6400 Loop terminal board
6400 OPTO isolated 485 board
6400 Loop Transmission board
Certified with the following options with requirements from EN 54: Part 2:
7.8
7.9.1
7.11
7.12.3
7.13
8.3
8.9
9.5
10
Notes:
1.
2.
6400/PSU
Output to fire alarm device(s)
Output to fire alarm routing equipment
Delays to outputs
Dependencies on more than one alarm signal - Type C
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablement of each address point
Test condition
This unit does not meet the requirements of EN
54-2 & 4 as a stand alone unit. It is intended for
use as part of the 6400 distributed network fire
alarm system. In order to meet the requirements
of EN 54-2 & 4 the unit must be used in
conjunction with the following units:

6400/PSU 8A Power supply with charger
Scope of approval does not include the operation of the network functionality.
8A Power supply with charger
201ad/06
Incorporating the following units:
SF40-472-48H-3
106
8A Power supply with charger
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Notes:
1.
2.
3.
6301
This unit does not meet the requirements of EN
54-2 & 4 as a stand alone unit. It is intended for
use as part of the 6400 distributed network fire
alarm system.
In order to meet the
requirements of EN 54-2 & 4 the unit must be
used in conjunction with the following units:
 6400/DCN Display and Control node
 6400/2LPN 2 Loop processing node and/or 6400/4LPN 4 Loop
processing node
Scope of approval does not include the operation of the network functionality.
Certified to EN 54-4 only.
1 Loop Analogue addressable control and indicating equipment
201ad/07
Incorporating the following units:
SF41-860-52F
SF41-850-50C
SF40-877-65
31-100-22
31-243-36
62-407-57
04-701-38
SF40-465-43F
31-275-44
SF40-879-67G
Main Board
Terminal Board
CP250 Printer Board
Backbox
Inner Plate
Door
Printer Mechanism
Series 9000 Power Supply Unit
Optional external 24 AH battery box
Network Card
Certified with the following options with requirements from EN 54: Part 2:
6302
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment
7.11
Delays to outputs
7.12.3
Dependencies on more than one alarm signal Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Note:
1. Scope of approval does not include the operation of the network functionality.
2 Loop Analogue addressable control and indicating equipment
201ad/08
Incorporating the following units:
SF41-860-52F
SF41-850-50C
SF40-877-65
31-100-22
31-243-36
62-407-57
04-701-38
SF40-465-43F
31-275-44
SF40-879-67G
Main Board
Terminal Board
CP250 Printer Board
Backbox
Inner Plate
Door
Printer Mechanism
Series 9000 Power Supply Unit
Optional external 24 AH battery box
Network Card
Certified with the following options with requirements from EN 54: Part 2
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment
7.11
Delays to outputs
7.12.3
Dependencies on more than one alarm signal Type C
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
Note:
1. Scope of approval does not include the operation of the network functionality.
20 Oct 2014
107
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificate No: 201af to EN54-4:2002+A2:
Control and indicating equipment
Certificated Products
9300EN
9800EN
9300EN-7Ah Dual 3 Amp 75W Power Supply with 7Ah batteries
9300EN-12Ah Dual 3 Amp 75W Power Supply with 12Ah batteries
9300EN-18Ah Dual 3 Amp 75W Power Supply with 18Ah batteries
9300EN-24Ah Dual 3 Amp 75W Power Supply with 24Ah batteries
9800EN-24Ah Dual output 8 Amp 200W Power Supply with 24Ah batteries
9800EN-40Ah Dual output 8 Amp 200W Power Supply with 40Ah batteries
9800EN-60Ah Dual output 8 Amp 200W Power Supply with 60Ah batteries
LPCB Ref.
No.
201af/01
201af/02
Schneider Electric Buildings Sweden AB
Dialoggatan 16, 126 37, Hägersten, Norway
Tel: +4687752700 • Fax: +4687449802
E-mail: [email protected] • Website: www.schneider-electric.com
Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
CFP704-4/SCAN/S
Four zone conventional control and indicating equipment
LPCB Ref.
No.
176b/13
Incorporating the units:
RPF0702005 Power supply PCB
SPF0724853 4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
10 Test condition
Schneider Electronic Buildings AS
Luhrtoppen 2, N-1470, Lørenskog, Norway
E-mail: [email protected] • Website: www.schneider-electric.no
Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
EPC4
Four zone conventional control and indicating equipment
LPCB Ref.
No.
176b/13
Incorporating the units:
RPF0702005 Power supply PCB
SPF0724853 4 Zone main control board
Certified with the following options with requirements from EN 54-2: 1997
7.8 Output to fire alarm devices(s)
7.11 Delays to outputs
10 Test condition
108
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
SHIELD FIRE, SAFETY AND SECURITY LTD
Redburn House, 2a Tonbridge Road, Romford, Essex RM3 8QE, United Kingdom
Tel: +44 207 712 1610 • Fax: +44 207 712 1578
E-mail: [email protected] • Website: www.shieldglobal.com
Certificate No: 548p-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
P-A2M
Intelligent 2 Loop, 30 Zone Analogue Addressable Control and Indicating
Equipment
LPCB Ref.
No.
548p/01
Incorporating the following units:
MB-220/ F7.820.826 Main board
SB-220/ F7.820.827 Switch board
TB-220/ F7.820.828 Loop interface board
PS-220/ F7.820.829b Power supply unit
ZP-220/ F7.820.312d Zone indication and intervention board
LC-A2M/ F7.820.1125 Loop board
Incorporating as optional modular units:
DB-A300/ F7.820.913a RS-232 board for configuration
P-A300P Printer module kit
P-A8M
Certified with the following options with requirements from EN 54 part 2:
7.8 Output to Fire Alarm Devices
7.10.1 Output to automatic Fire Protection Equipment Type A
7.11 Delays to outputs
8.3 Fault signals from points
9.5 Disablement of addressable points
Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment
548p/02
Incorporating the following units:
SB-800/ F7.820.1238
Indication board
LCIFP8/ F7.820.1239
Loop board
PB-800/ F7.820.1311
Power board
ZP-800/ F7.820.1312
ZCP board
KB-800/ F7.820.1326
Keypad board
MB-800/ F7.820.1237
Main board
MO-800/ F7.820.1310
Mother board
Incorporating as optional modular units:
P-9935/ F7.820.1313
USB communication board
Optional language variants:
10104673 Portuguese language variant
10104675 Hungarian language variant
Certified with the following options with requirements from EN 54 Part 2:
P-C202A
7.8
Output to fire alarm devices
7.9.1
Output to fire routing equipment
7.9.2
Alarm confirmation input from fire routing equipment
7.10.1
Output type A
7.10.2
Output type B
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal - Type A
7.12.2
Dependencies on more than one alarm signal - Type B
7.13
Alarm counter
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
2 Zone Conventional Control and Indicating Equipment
548p/03
Incorporating the following modules:
FC-102A/ F7.843.399
Membrane
CB-102A/ F2.908.1719 Control board with integrated PSE
DB-102A/ F2.908.1722 Display board
20 Oct 2014
109
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Optional modules:
10104648
Traditional Chinese text variant
CF-102A/ F7.843.421 Membrane
P-C204A
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1 Output to fire routing equipment
7.11 Delays to outputs
10
Test condition
4 Zone Conventional Control and Indicating Equipment
548p/04
Incorporating the following modules:
FC-104A/ F7.843.400
Membrane
CB-104A/ F2.908.1718 Control board with integrated PSE
DB-104A/ F2.908.1721 Display board
Optional modules:
10104649
Traditional Chinese text variant
CF-104A/ F7.843.422 Membrane
P-C208A
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1 Output to fire routing equipment
7.11 Delays to outputs
10
Test condition
8 Zone Conventional Control and Indicating Equipment
548p/05
Incorporating the following modules:
FC-108A/ F7.843.401
Membrane
CB-108A/ F2.908.1675 Control board with integrated PSE
DB-108A/ F2.908.1720 Display board
Optional modules:
10104650 Traditional Chinese text variant
CF-108A/ F7.843.423 Membrane
P-C216A
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1 Output to fire routing equipment
7.11 Delays to outputs
10
Test condition
16 Zone Conventional Control and Indicating Equipment
548p/06
Incorporating the following modules:
FC-116A/ F7.843.402
Membrane
XB-116A/ F2.908.1724 Control board with integrated PSE
DB-116A/ F2.908.1676 Display board
CB-116A/ F7.820.1677 Expansion board
P-A2M/1
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1 Output to fire routing equipment
7.11 Delays to outputs
10
Test condition
Intelligent 1 Loop, 30 Zone Analogue Addressable Control and Indicating Equipment
548p/08
Incorporating the following units:MB-220/ F7.820.826
Main board
SB-220/ F7.820.827
Switch board
TB-220/ F7.820.828
Loop interface board
PS-220/ F7.820.829b
Power supply unit
ZP-220/ F7.820.312d
Zone indication and intervention board
Incorporating as optional modular units:DB-A300/ F7.820.913a
RS-232 board for
configuration
P-A300P Printer module kit
LC-A2M/ F7.820.1125 Loop board (for loop expansion)
Certified with the following options with requirements from EN 54 part 2:7.8
Output to Fire Alarm Devices
7.10.1
Output to automatic Fire Protection Equipment Type A
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
110
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Note: Can be extended to 2-loop panel by adding LC-A2M
Incorporating as optional modular units:
Incorporating as optional modular units:
DB-A300/ F7.820.913a RS-232 board for configuration
P-A300P Printer module kit
LC-A2M/ F7.820.1125 Loop board (for loop expansion)
Siemens Switzerland Limited, Building Technologies Division
International Headquarters, Gubelstrasse 22, CH-6301 Zug, Switzerland
Tel: +41 (0) 41 724 24 24 • Fax: +41 (0) 41 724 35 22
Manufacturing at:
Volketswil Factory, Industriestrasse 22, CH-8604 Volketswil, Switzerland
Tel: +41 1 922 6111 • Fax: +41 1 922 6450
UK Sales:
Fire Safety and Security Limited
Tel: +44 (0)1734 783703 • Fax: +44 (0)1734 775750
Certificate No: 126h-(cl1) to EN 54-2: 1997 and EN 54-4: 1997
Certificate No: 126aw-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 126aw-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 531q-(cl-1) to EN 54-2:1997 + A1:2006 and EN 54-4:1997 + A1:2002 + A2:2006
Certificate No: 126bs/01 to EN 54-13:2005
Control and indicating equipment
Certificated Products
FC2020
Control and indicating equipment
LPCB Ref.
No.
126aw/01
Incorporating as modular units:
FCM2028
FP2001-A1
FCI2002-A1
FHA2002-A1
Operating unit
70W Power supply
Periphery board (2-Loop)
Rear housing
and as optional modular units:
FCM2029-A2
Operating unit
FCM2027
PMI- & mainboard
FCM2005-A2
Operating add-on module
FCM2006-A2
Operating add-on module (2 LED indicator)
FTO2001-A1
Event printer
FCI2003-A1
Loop extension (FDnet)
FTO2002-A1
24 LED indicator (internal)
FN2001-A1
Networking module (See Note 1)
FHA2003-A1
Rear housing (standard)
FN2008-A1
Ethernet Switch (See Note 1)
FCA2001-A1
Isolated RS232 module
FCA2002-A1
Isolated RS485 module
FCI2001-D1
Fire brigade periphery module
FCM2003-C2
Operating unit (incl. FBA-Term.CH)
FCM2003-N2
Operating unit (incl. EVAC-Term.NL)
FTO2004-C1
PCB compl. FBA-Terminal (CH)
FTO2007-N1
PCB compl. EVAC- module (NL)
SV 24V-150W
150W Power supply
REDUX Redundancy module
20 Oct 2014
111
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Certified with the following Options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10.1
7.10.2
7.10.3
7.10.4
7.11
7.12.2
7.12.3
7.13
8.3
8.9
9.5
10
Output to fire alarm devices
Output to fire alarm routing equipment
Alarm Confirmation from fire alarm routing equipment
Output to automatic fire protection equipment Type A
Output to automatic fire protection equipment Type B
Output to automatic fire protection equipment Type C
Fault monitoring of automatic fire protection equipment
Delays to outputs
Coincidence detection type B (only for FDnet & MS9i line
technology)
Coincidence detection type C
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Note:
1)
2)
FC2030
Scope of approval does not include the operation of the network
functionality.
This approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Control and indicating equipment
126aw/02
Incorporating as modular units:
FCM2028
SV24V-150W
FCI2002-A1
FHA2003-A1
FCA2007-A1
Operating unit
150W Power supply
Periphery board (2-Loop)
Rear housing
Card cage (2 slot)
and as optional modular units:
FCM2029-A2
Operating unit
FCM2027
PMI- & mainboard
FCM2007-A2
Operating add-on module (4 LED ind.)
FCM2015-D1
Operating add-on (DA ind.)
FTO2001-A1
Event printer
FCI2003-A1
Loop extension (FDnet)
FCI2007-A1
I/O card (monitored)
FCI2009-A1
I/O Card
FTO2002-A1
24 LED indicator (internal)
FN2001-A1
Networking module (See Note 1)
FN2008-A1
Ethernet Switch (See Note 1)
FCA2001-A1
Isolated RS232 module
FCA2002-A1
Isolated RS485 module
FCI2001-D1
Fire brigade periphery module
FTO2003-D1
Emergency alarm indicator
FCA2006-A1
Connection mod. (Card Cage)
FCI2008-A1
I/O card (programmable)
FCL2001-A1
Line card (FDnet)
FCL2002-A1
Line card (collective)
FCL2003-A1
Line card (MS9i)
REDUX Redundancy module
Certified with the following Options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10.1
7.10.2
7.10.3
7.10.4
7.11
7.12.1
112
Output to fire alarm devices
Output to fire alarm routing equipment
Alarm Confirmation from fire alarm routing equipment
Output to automatic fire protection equipment Type A
Output to automatic fire protection equipment Type B
Output to automatic fire protection equipment Type C
Fault monitoring of automatic fire protection equipment
Delays to outputs
Coincidence detection type A (only for MS9i & collective line
technology)
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.12.2
7.12.3
7.13
8.3
8.9
9.5
10
Coincidence detection type B (only for FDnet & MS9i line
technology)
Coincidence detection type C
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Note:
1)
2)
FC2040
Scope of approval does not include the operation of the network
functionality.
This approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Control and indicating equipment
126aw/03
Incorporating as modular units;
FCM2028
FCM2007-A2
SV24V-150W
FCI2004-A1
FHA2003-A1
Operating unit
Operating add-on (4 LED ind.)
150W Power supply
Periphery board (4-Loop)
Rear housing
and as optional modular units:
FCM2029-A2
Operating unit
FCM2027
PMI- & mainboard
FCM2005-A2
Operating add-on module
FCM2006-A2
Operating add-on module (2 LED indicator)
FTO2001-A1
Event printer
FCI2003-A1
Loop extension (FDnet)
FTO2002-A1
24 LED indicator (internal)
FN2001-A1
Networking module (See Note 1)
FN2008-A1
Ethernet Switch (See Note 1)
FCA2001-A1
Isolated RS232 module
FCA2002-A1
Isolated RS485 module
FCI2001-D1
Fire brigade periphery module
FCM2003-C2
Operating unit (incl. FBA-Term.CH)
FCM2003-N2
Operating unit (incl. EVAC-Term.NL)
FTO2004-C1
PCB compl. FBA-Terminal (CH)
FTO2007-N1
PCB compl. EVAC- module (NL)
REDUX Redundancy module
Certified with the following Options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10.1
7.10.2
7.10.3
7.10.4
7.11
7.12.2
7.12.3
7.13
8.3
8.9
9.5
10
Output to fire alarm devices
Output to fire alarm routing equipment
Alarm Confirmation from fire alarm routing equipment
Output to automatic fire protection equipment Type A
Output to automatic fire protection equipment Type B
Output to automatic fire protection equipment Type C
Fault monitoring of automatic fire protection equipment
Delays to outputs
Coincidence detection type B (only for FDnet & MS9i line
technology)
Coincidence detection type C
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Note:
1)
2)
FC2060
20 Oct 2014
Scope of approval does not include the operation of the network
functionality.
This approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Control and indicating equipment
126aw/04
113
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating as modular units:
FCM2028
SV24V-150W
FCI2004-A1
FHA2005-A1
FCA2008-A1
Operating unit
150W Power supply
Periphery board (4-Loop)
Rear housing
Card cage (5 slot)
and as optional modular units:
FCM2029-A2
Operating unit
FCM2027
PMI- & mainboard
FCM2007-A2
Operating add-on module (4 LED ind.)
FCM2015-D1
Operating add-on (DA ind.)
FTO2001-A1
Event printer
FCI2003-A1
Loop extension (FDnet)
FTO2002-A1
24 LED indicator (internal)
FCI2009-A1
I/O Card, monitor
FCI2007-A1
I/O Card, RT
FN2001-A1
Networking module (See Note 1)
FN2008-A1
Ethernet Switch (See Note 1)
FCA2001-A1
Isolated RS232 module
FCA2002-A1
Isolated RS485 module
FCI2001-D1
Fire brigade periphery module
FTO2003-D1
Emergency alarm indicator
FCA2006-A1
Connection mod. (Card Cage)
FCI2008-A1
I/O card (programmable)
FCL2001-A1
Line card (FDnet)
FCL2002-A1
Line card (collective)
FCL2003-A1
Line card (MS9i)
REDUX Redundancy module
Certified with the following Options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10.1
7.10.2
7.10.3
7.10.4
7.11
7.12.1
7.12.2
7.12.3
7.13
8.3
8.9
9.5
10
Output to fire alarm devices
Output to fire alarm routing equipment
Alarm Confirmation from fire alarm routing equipment
Output to automatic fire protection equipment Type A
Output to automatic fire protection equipment Type B
Output to automatic fire protection equipment Type C
Fault monitoring of automatic fire protection equipment
Delays to outputs
Coincidence detection type A (only for MS9i & collective line
technology)
Coincidence detection type B (only for FDnet & MS9i line
technology)
Coincidence detection type C
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Note:
1)
2)
FC721
Scope of approval does not include the operation of the network
functionality.
This approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Control and indicating equipment
126aw/05
Incorporating as modular units:
FCM7204-Z3
FP2001-A1
FCI2010-A1
FHA2002-A1
Operating unit
70W Power supply
Periphery board (1-Loop)
Rear housing
and as optional modular units:
FCM7205-Y3
FCM7203-H3
114
Operating unit (+ LED Ind.)
Operating unit (+ EVAC-Term.)
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
FCM2027
FTO2001-A1
FTO2002-A1
FN2001-A1
FCA2001-A1
FCA2002-A1
PMI- & mainboard
Event printer
24 LED indicator (internal)
Networking module (See Note 1)
Isolated RS232 module
Isolated RS485 module
Certified with the following Options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10.1
7.10.2
7.10.3
7.10.4
7.11
7.12.2
7.12.3
7.13
8.3
8.9
9.5
10
Output to fire alarm devices
Output to fire alarm routing equipment
Alarm Confirmation from fire alarm routing equipment
Output to automatic fire protection equipment Type A
Output to automatic fire protection equipment Type B
Output to automatic fire protection equipment Type C
Fault monitoring of automatic fire protection equipment
Delays to outputs
Coincidence detection type B (only for FDnet & MS9i line
technology)
Coincidence detection type C
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Note:
1)
2)
FC722
Scope of approval does not include the operation of the network
functionality.
This approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Control and indicating equipment
126aw/06
Incorporating as modular units:
FCM7204-Z3
SV24V/150W
FCI2002-A1
FHA2003-A1
Operating unit
150W Power supply
Periphery board (2-Loop)
Rear housing
and as optional modular units:
FP2001-A1
70W Power supply
FHA2001-A1
Rear housing
FCM7205-Y3
Operating unit (+ LED Ind.)
FCM7203-H3
Operating unit (+ EVAC-Term.)
FCM2027
PMI- & mainboard
FTO2001-A1
Event printer
FCI2003-A1
Loop extension (FDnet)
FTO2002-A1
24 LED indicator (internal)
FN2001-A1
Networking module (See Note 1)
FN2008-A1
Ethernet Switch (See Note 1)
FCA2001-A1
Isolated RS232 module
FCA2002-A1
Isolated RS485 module
FCI2001-D1
Fire brigade periphery module
REDUX Redundancy module
Certified with the following Options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10.1
7.10.2
7.10.3
7.10.4
7.11
7.12.2
7.12.3
20 Oct 2014
Output to fire alarm devices
Output to fire alarm routing equipment
Alarm Confirmation from fire alarm routing equipment
Output to automatic fire protection equipment Type A
Output to automatic fire protection equipment Type B
Output to automatic fire protection equipment Type C
Fault monitoring of automatic fire protection equipment
Delays to outputs
Coincidence detection type B (only for FDnet & MS9i line
technology)
Coincidence detection type C
115
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.13
8.3
8.9
9.5
10
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablement of addressable points
Test condition
1)
Scope of approval does not include the operation of the network
functionality.
This approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Note:
2)
FC724
Control and indicating equipment
126aw/07
Incorporating as modular units:
FCM7204-Z3
SV24V/150W
FCI2004-A1
FHA2003-A1
Operating unit
150W Power supply
Periphery board (4-Loop)
Rear housing
and as optional modular units:
FCM7205-Y3
Operating unit (+ LED Ind.)
FCM7203-H3
Operating unit (+ EVAC-Term.)
FCM2027
PMI- & mainboard
FCM2007-A2
Operating add-on module (4 LED ind.)
FTO2001-A1
Event printer
FCI2003-A1
Loop extension (FDnet)
FTO2002-A1
24 LED indicator (internal)
FN2001-A1
Networking module (See Note 1)
FN2008-A1
Ethernet Switch (See Note 1)
FCA2001-A1
Isolated RS232 module
FCA2002-A1
Isolated RS485 module
FCI2001-D1
Fire brigade periphery module
REDUX Redundancy module
Certified with the following Options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10.1
7.10.2
7.10.3
7.10.4
7.11
7.12.2
7.12.3
7.13
8.3
8.9
9.5
10
Output to fire alarm devices
Output to fire alarm routing equipment
Alarm Confirmation from fire alarm routing equipment
Output to automatic fire protection equipment Type A
Output to automatic fire protection equipment Type B
Output to automatic fire protection equipment Type C
Fault monitoring of automatic fire protection equipment
Delays to outputs
Coincidence detection type B (only for FDnet & MS9i line
technology)
Coincidence detection type C
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Note:
1)
2)
FC726
Scope of approval does not include the operation of the network
functionality.
This approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Control and indicating equipment
126aw/08
Incorporating as modular units:
FCM7204-Z3
SV24V/150W
FCI2004-A1
FHA2005-A1
FCA2008-A1
Operating unit
150W Power supply
Periphery board (4-Loop)
Rear housing
Card cage (5 slot)
and as optional modular units:
116
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
FCM7205-Y3
FCM2027
FCM2007-A2
FCM2015-DA
FTO2001-A1
FCI2003-A1
FTO2002-A1
FN2001-A1
FN2008-A1
FCA2001-A1
FCA2002-A1
FCI2001-D1
FTO2003-D1
FCA2006-A1
FCI2008-A1
FCL2001-A1
FCL2002-A1
FCL2003-A1
REDUX
Operating unit (+ LED Ind.)
PMI- & mainboard
Operating add-on module (4 LED ind.)
Operating add-on module (DA ind.)
Event printer
Loop extension (FDnet)
24 LED indicator (internal)
Networking module (See Note 1)
Ethernet Switch (See Note 1)
Isolated RS232 module
Isolated RS485 module
Fire brigade periphery module
Emergency alarm indicator
Connection mod. (Card Cage)
I/O card (programmable)
Line card (FDnet)
Line card (collective)
Line card (MS9i)
Redundancy module
Certified with the following Options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
Output to fire alarm devices
Output to fire alarm routing equipment
Alarm Confirmation from fire alarm routing
7.10.1
Output to automatic fire protection equipment Type
7.10.2
Output to automatic fire protection equipment Type
7.10.3
Output to automatic fire protection equipment Type
7.10.4
Fault monitoring of automatic fire protection
equipment
A
B
C
equipment
7.11
7.12.1
collective line technology)
7.12.2
MS9i line technology)
7.12.3
7.13
8.3
8.9
9.5
10
Delays to outputs
Coincidence detection type A (only for MS9i &
Coincidence detection type B (only for FDnet &
Coincidence detection type C
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Note:
Scope of approval does not include the operation of the network
functionality.
This approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13.
FT2040
Fire detection terminal for use with FC2020, FC2030, FC2040 & FC2060 control and
indicating equipment
126aw/R0
1
Incorporating as modular units:
FCM2029-A2
FTI2001-A1
FHA2001-A1
Operating unit
Fire terminal board
Rear housing
and as optional modular units:
FCM2028
FCM2027
FTO2001-A1
FTO2002-A1
FN2001-A1
FN2008-A1
FCA2001-A1
20 Oct 2014
Operating unit
PMI- & mainboard
Event printer
24 LED indicator (internal)
Networking module (See Note 1)
Ethernet Switch (See Note 1)
Isolated RS232 module
117
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
FCA2002-A1
Isolated RS485 module
FCM2003-C2
Operating unit (incl. FBA-Term.CH)
FCM2003-N2
Operating unit (incl. EVAC-Term.NL)
FTO2004-C1
PCB compl. FBA-Terminal (CH)
FTO2007-N1
PCB compl. EVAC- module (NL)
FP2001-A1
70W Power supply
H28G200
Housing base
REDUX Redundancy module
Note:
1)
2)
FT724
Scope of approval does not include the operation of the network
functionality.
This approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Fire detection terminal for use with FC721, FC722 & FC724 control and indicating
equipment
126aw/R0
2
Incorporating as modular units:
FCM7204-Z3
FTI2001-A1
FHA2001-A1
Operating unit
Fire terminal board
Rear housing
and as optional modular units:
FCM7205-Y3
Operating unit (+ LED Ind.)
FCM7203-H3
Operating unit (+ EVAC-Term.)
FCM2027
PMI- & mainboard
FTO2001-A1
Event printer
FTO2002-A1
24 LED indicator (internal)
FN2001-A1
Networking module (See Note 1)
FN2008-A1
Ethernet Switch (See Note 1)
FCA2001-A1
Isolated RS232 module
FCA2002-A1
Isolated RS485 module
FP2001-A1
70W Power supply
H28G200
Housing base
REDUX Redundancy module
Note:
1)
2)
CS1140
Scope of approval does not include the operation of the network
functionality.
This approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Control and indicating equipment
Comprising the following products:
CC1140 Control and indicating equipment
CT11 Operators console
CI1140 Integrated central unit
Incorporating as modular units:
E3X100 Master module
126h/01
E3X102 Master Module
E3X103 Master Module
E3X120 Master card Cl1145
E3C010 Battery charging module
E3C011 Battery charging module
B2F020 Converter
B2F040 Converter
E3M140 Line module FD20
E3M070 Line module "Interactive"
E3M071 Line module Interactive
K3M140 Line card FD20
K3M071 Line card Interactive to E3X120
K3M080 Line card Collective
B3Q460 Control console Algopilot "CT11"
B3Q321 Fire department control panel (Swiss)
E3G050 Contacts control unit
E3G070 Universal control unit
E3I020 RS232 unit
K3I060 RS232 module
E3L020 I/O control unit
E3M080 Group line unit
118
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
K3R071 Synoptic - Algo pilot
K3R070 Synoptic - Algo pilot
K3I050 LON/Synoptic converter
E3M060 MS9i module
E3G091 Remote TX i/face
E3M110 AnalogPLUS module
E3M111 Line module AnaloguPLUS
K3M111 Line card AnalogPLUS
B3R051 Parallel indicator panel (24 x 2 LED)
E3G080 Control module Extinguishing
B3Q440 Control console Extinguishing module
E3G060 Control monitored module
E3H020 C-Bus Gateway module
E3I040 I-Bus/LON module
B3Q560/B3Q600 Terminals China
B3Q580 Text display terminal
B3Q590 Text control terminal Nordic
B3Q660 Operator console Standard Algopilot "CT11"
B3Q661 Operator console Standard Algopilot "CT11"
B3Q680 Control console Nordic Algopilot "CT11"
B3Q565 Operator control Asia Pacific Algopilot "CT11"
K3N010 RAM - Extension
K3I110 LON Input/Output Box
E3M171 Line Module Ex Interactive
K5L020 Multi-Sect. Extinguishing P.C.B
K3G060 Relay Card to Synptic BUS
E3G100 Emergency Operation Link
E3G110 Emergency Link to E3G080
K3R072 Synoptical Driver
M3C080 Horn Monitoring Module
Certified with the following Options with requirements from EN 54-2:1997
7.8
Outputs to fire alarm devices
7.9
Output to fire alarm routing equipment
7.10
Output to Fire Protection Equipment
7.11
Delays to outputs
7.12
Coincidence detection
7.13
Alarm counter
8.3
Fault signals from points
8.4
Complete failure of power supply
9.5
Disablement of addressable points
10
Test condition
11
Standardised input/output interface
FC121-ZA , FC122-ZA
Notes:
1) Compliance with clause 12.6.2 of EN 54-2:1997 requires LCD screen saving feature to
be disabled for the alarm condition.
Two zone conventional control and indicating equipment
Four zone conventional control and indicating equipment
531q/01
Incorporating the units:
PCBA FC121-ZA Two zone main control board with integrated power supply
PCBA FC122-ZA Four zone main control board with integrated power supply
Optional modules:
FCA1203-Z1 Output card 2M2R
FTO1201-H1 EVAC module (applicable on NL model only)
FCA1206-Z1 Key switch set ( applicable on Nordic SE model only)
FC123-ZA , FC124-ZA
20 Oct 2014
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10.1 Outputs to fire protection equipment (Type A)
7.11
Delays to outputs
7.12.1 Dependencies on more than one alarm signal (Type A dependency)
7.12.2 Dependencies on more than one alarm signal (Type B dependency)
7.13 Alarm counter
8.9
Output to fault warning routing equipment
10
Test condition
Eight zone conventional control and indicating equipment
Twelve zone conventional control and indicating equipment
531q/02
119
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating the units:
PCBA FC123-ZA Eight zone main control board
PCBA FC124-ZA Twelve zone main control board
FP2015-A1 Power supply (70W)
Optional modules:
FCA1203-Z1 Output card 2M2R
FTO1202-Z1 Zone indication field 12x2 LED
FTO1203-H1 EVAC module (applicable on NL model only)
FCA1206-Z1 Key switch set (applicable on Nordic SE model only)
Certified with the following options with requirements from EN 54-2: 1997
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.13
Alarm counter 8.9 Output to fault warning routing equipment
10
Test condition
Note:
This approval does not constitute compliance with the fire detection and alarm systems
requirements of EN 54-13.
1
0
/
s
b
6
2
1
t
n
e
m
p
i
u
q
e
g
n
i
t
a
c
i
d
n
i
d
n
a
l
o
r
t
n
o
c
l
a
n
o
i
t
n
e
v
n
o
c
e
n
o
z
o
w
T
A
Z
1
2
1
C
F
t
n
e
m
p
i
u
q
e
g
n
i
t
a
c
i
d
n
i
d
n
a
l
o
r
t
n
o
c
l
a
n
o
i
t
n
e
v
n
o
c
e
n
o
z
r
u
o
F
A
Z
2
2
1
C
F
t
n
e
m
p
i
u
q
e
g
n
i
t
a
c
i
d
n
i
d
n
a
l
o
r
t
n
o
c
l
a
n
o
i
t
n
e
v
n
o
c
e
n
o
z
t
h
g
i
E
A
Z
3
2
1
C
F
t
n
e
m
p
i
u
q
e
g
n
i
t
a
c
i
d
n
i
d
n
a
l
o
r
t
n
o
c
l
a
n
o
i
t
n
e
v
n
o
c
e
n
o
z
e
v
l
e
w
T
A
Z
4
2
1
C
F
y
l
p
p
u
S
r
e
w
o
P
y
l
p
p
u
s
r
e
w
o
p
l
a
n
r
e
t
n
i
E
I
C
1
A
5
1
0
2
P
F
e
c
i
v
e
D
t
u
p
t
u
O
e
l
u
d
o
M
t
u
p
t
u
O
1
Z
9
0
2
1
A
C
F
e
c
i
v
e
D
t
u
p
t
u
O
/
t
u
p
n
I
r
o
t
a
l
o
s
i
t
i
u
c
r
i
c
t
r
o
h
s
h
t
i
w
e
l
u
d
o
m
t
u
p
t
u
o
/
t
u
p
n
I
2
9
1
1
C
D
s
r
o
t
c
e
t
e
D
l
a
i
c
r
e
m
m
o
C
r
o
t
a
l
o
s
i
t
i
u
c
r
i
c
t
r
o
h
s
h
t
i
w
r
o
t
c
e
t
e
d
r
o
s
n
e
s
i
t
l
u
m
e
l
b
a
s
s
e
r
d
d
a
e
u
g
o
l
a
n
A
9
1
4
2
T
O
O
D
F
r
o
t
a
l
o
s
i
t
i
u
c
r
i
c
t
r
o
h
s
h
t
i
w
r
o
t
c
e
t
e
d
r
o
s
n
e
s
i
t
l
u
M
9
A
1
4
2
T
O
O
D
F
r
o
t
a
l
o
s
i
t
i
u
c
r
i
c
t
r
o
h
s
h
t
i
w
r
o
t
c
e
t
e
d
m
a
e
b
e
l
b
a
s
s
e
r
d
d
a
e
u
g
o
l
a
n
A
9
1
4
2
L
D
F
t
n
e
m
e
c
n
a
h
n
e
l
a
m
r
e
h
t
h
t
i
w
r
o
t
c
e
t
e
d
e
k
o
m
s
c
i
r
t
c
e
l
e
o
t
o
h
p
l
a
n
o
i
t
n
e
v
n
o
C
C
0
2
3
H
O
r
o
t
a
l
o
s
i
t
i
u
c
r
i
c
t
r
o
h
s
h
t
i
w
r
o
t
c
e
t
e
d
r
o
s
n
e
s
i
t
l
u
m
e
l
b
a
s
s
e
r
d
d
a
e
u
g
o
l
a
n
A
0
4
7
H
O
O
r
o
t
c
e
t
e
d
e
k
o
m
s
c
i
r
t
c
e
l
e
o
t
o
h
p
l
a
n
o
i
t
n
e
v
n
o
c
e
f
a
s
y
l
l
a
c
i
s
n
i
r
t
n
I
x
E
A
1
0
1
1
O
D
r
o
t
c
e
t
e
d
t
a
e
h
R
1
A
s
s
a
l
c
l
a
n
o
i
t
n
e
v
n
o
C
A
1
0
1
1
T
D
r
o
t
c
e
t
e
d
t
a
e
h
R
1
A
s
s
a
l
c
e
f
a
s
y
l
l
a
c
i
s
n
i
r
t
n
i
l
a
n
o
i
t
n
e
v
n
o
C
x
E
A
1
0
1
1
T
D
r
o
t
c
e
t
e
d
t
a
e
h
B
s
s
a
l
c
l
a
n
o
i
t
n
e
v
n
o
C
A
2
0
1
1
T
D
120
20 Oct 2014
CONTROL AND INDICATING EQUIPMENT
PART 1: SECTION 3
r
o
t
c
e
t
e
d
t
a
e
h
B
s
s
a
l
c
e
f
a
s
y
l
l
a
c
i
s
n
i
r
t
n
i
l
a
n
o
i
t
n
e
v
n
o
C
x
E
A
2
0
1
1
T
D
r
o
t
c
e
t
e
d
e
k
o
m
s
c
i
r
t
c
e
l
e
o
t
o
h
p
l
a
n
o
i
t
n
e
v
n
o
C
A
1
0
1
1
O
D
r
o
t
c
e
t
e
d
t
a
e
h
R
1
A
s
s
a
l
c
l
a
n
o
i
t
n
e
v
n
o
C
C
0
2
3
I
H
r
o
t
c
e
t
e
d
t
a
e
h
2
A
s
s
a
l
c
l
a
n
o
i
t
n
e
v
n
o
C
C
2
2
3
I
H
r
o
t
c
e
t
e
d
e
k
o
m
s
c
i
r
t
c
e
l
e
o
t
o
h
p
l
a
n
o
i
t
n
e
v
n
o
C
C
0
2
3
P
O
s
r
o
t
c
e
t
e
D
e
m
a
l
F
r
o
t
a
l
o
s
i
t
i
u
c
r
i
c
t
r
o
h
s
h
t
i
w
r
o
t
c
e
t
e
d
e
m
a
l
f
d
e
r
a
r
f
n
i
e
l
b
a
s
s
e
r
d
d
a
e
u
g
o
l
a
n
A
9
1
2
2
F
D
F
r
o
t
a
l
o
s
i
t
i
u
c
r
i
c
t
r
o
h
s
h
t
i
w
r
o
t
c
e
t
e
d
e
m
a
l
f
d
e
r
a
r
f
n
i
e
l
b
a
s
s
e
r
d
d
a
e
u
g
o
l
a
n
A
9
1
4
2
F
D
F
r
o
t
a
l
o
s
i
t
i
u
c
r
i
c
t
r
o
h
s
h
t
i
w
r
o
t
c
e
t
e
d
e
m
a
l
f
d
e
r
a
r
f
n
i
e
l
b
a
s
s
e
r
d
d
a
e
u
g
o
l
a
n
A
1
9
1
1
F
D
r
o
t
c
e
t
e
D
e
m
a
l
F
d
e
R
a
r
f
n
I
e
l
b
a
s
s
e
r
d
d
A
e
u
g
o
l
a
n
A
2
9
1
1
F
D
s
t
n
i
o
P
l
l
a
C
l
a
u
n
a
M
d
e
t
n
u
o
m
h
s
u
l
f
,
t
n
i
o
p
l
l
a
c
l
a
u
n
a
m
r
o
o
d
n
I
1
0
1
1
M
D
t
n
i
o
p
l
l
a
c
l
a
u
n
a
m
r
o
o
d
t
u
o
d
n
a
r
o
o
d
n
i
l
a
n
o
i
t
n
e
v
n
o
C
4
0
1
1
M
D
t
n
i
o
p
l
l
a
c
l
a
u
n
a
m
r
o
o
d
t
u
o
d
n
a
r
o
o
d
n
i
l
a
n
o
i
t
n
e
v
n
o
C
C
0
2
3
T
M
t
n
e
m
e
l
E
s
s
a
l
G
e
l
b
a
t
t
e
s
e
R
n
o
N
h
t
i
w
t
n
i
o
P
l
l
a
C
l
a
u
n
a
M
r
o
o
d
t
u
O
/
r
o
o
d
n
I
A
e
p
y
T
e
v
i
t
c
e
l
l
o
C
G
R
1
0
1
1
M
D
F
t
n
e
m
e
l
E
c
i
t
s
a
l
P
e
l
b
a
t
t
e
s
e
R
h
t
i
w
t
n
i
o
P
l
l
a
C
l
a
u
n
a
M
r
o
o
d
t
u
O
/
r
o
o
d
n
I
A
e
p
y
T
e
v
i
t
c
e
l
l
o
C
P
R
1
0
1
1
M
D
F
t
n
e
m
e
l
E
s
s
a
l
G
e
l
b
a
t
t
e
s
e
R
n
o
N
h
t
i
w
t
n
i
o
P
l
l
a
C
l
a
u
n
a
M
r
o
o
d
t
u
O
/
r
o
o
d
n
I
A
e
p
y
T
l
a
n
o
i
t
n
e
v
n
o
C
G
R
A
1
0
1
1
M
D
F
t
n
e
m
e
l
E
c
i
t
s
a
l
P
e
l
b
a
t
t
e
s
e
R
h
t
i
w
t
n
i
o
P
l
l
a
C
l
a
u
n
a
M
r
o
o
d
t
u
O
/
r
o
o
d
n
I
A
e
p
y
T
l
a
n
o
i
t
n
e
v
n
o
C
P
R
A
1
0
1
1
M
D
F
t
n
e
m
e
l
E
s
s
a
l
G
e
l
b
a
t
t
e
s
e
R
n
o
N
h
t
i
w
t
n
i
o
P
l
l
a
C
l
a
u
n
a
M
r
o
o
d
t
u
O
/
r
o
o
d
n
I
A
e
p
y
T
e
v
i
t
c
e
l
l
o
C
)
F
(
G
R
1
0
1
1
M
D
F
e
l
b
a
t
t
e
s
e
R
h
t
i
w
t
n
i
o
P
l
l
a
C
l
a
u
n
a
M
r
o
o
d
t
u
O
/
r
o
o
d
n
I
A
e
p
y
T
e
v
i
t
c
e
l
l
o
C
)
F
(
P
R
1
0
1
1
M
D
F
.
t
n
e
m
e
l
E
c
i
t
s
a
l
P
e
l
b
a
t
t
e
s
e
R
n
o
g
n
i
l
l
e
b
a
l
h
c
n
e
r
F
;
t
n
e
m
e
l
E
c
i
t
s
a
l
P
s
e
c
i
v
e
D
g
n
i
n
r
a
W
m
r
a
l
A
e
s
a
b
r
e
d
n
u
o
s
)
e
v
i
t
c
e
l
l
o
c
(
l
a
n
o
i
t
n
e
v
n
o
c
e
u
g
o
l
a
n
A
2
9
2
B
S
D
F
r
e
d
n
u
o
S
P
L
B
/
A
e
p
y
T
l
a
n
o
i
t
n
e
v
n
o
C
i
n
h
s
o
R
P
L
O
R
:
e
t
o
n
l
a
r
e
n
e
G
l
e
d
o
m
o
t
r
e
f
e
r
,
c
t
e
s
e
n
o
t
r
e
d
n
u
o
s
,
n
o
i
t
a
c
i
f
i
s
s
a
l
c
t
a
e
h
,
s
e
i
t
i
v
i
t
i
s
n
e
s
d
e
v
o
r
p
p
a
g
n
i
d
u
l
c
n
i
t
c
u
d
o
r
p
l
a
u
d
i
v
i
d
n
i
h
c
a
e
n
o
n
o
i
t
a
m
r
o
f
n
i
r
e
h
t
r
u
f
r
o
F
m
o
c
.
e
v
i
l
k
o
o
b
d
e
r
.
w
w
w
n
o
r
o
k
o
o
B
d
e
R
e
h
t
f
o
n
o
i
t
c
e
s
e
t
a
i
r
p
o
r
p
p
a
e
h
t
n
i
)
s
(
r
e
b
m
u
n
e
c
n
e
r
e
f
e
r
SMS (Novar Systems Ltd)
Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United Kingdom
Tel: +44 (0)116 246 2100 • Fax: +44 (0)116 246 2016
Website: www.smsfire.co.uk
Certificate No: 042bc to EN 54-2: 1997+ A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
121
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
Sentri1
LPCB Ref.
No.
042bc/01
Single loop analogue addressable control and indicating equipment
Incorporating as modular units:
2434-881 Mother board
2434-862 Power supply
2434-887 H.M.I (Human Machine Interface)
Certified with the following options with requirements from EN 54 Part 2:
Sentri1-SP
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
10
Test condition
Single loop analogue addressable control and indicating equipment
(Spanish language variant)
Incorporating as modular units:
2434-881 Mother board
2434-862 Power supply
2434-887 H.M.I (Human Machine Interface)
042bc/02
Certified with the following options with requirements from EN 54 Part 2:
Sentri1-PO
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
10
Test condition
Single loop analogue addressable control and indicating equipment
(Portuguese language variant)
Incorporating as modular units:
2434-881 Mother board
2434-862 Power supply
2434-887 H.M.I (Human Machine Interface)
042bc/03
Certified with the following options with requirements from EN 54 Part 2:
Sentri2
Sentri2-PO
Sentri2-SP
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
10
Test condition
Two loop analogue addressable control and indicating equipment (English language)
Two loop analogue addressable control and indicating equipment (Portuguese language
variant)
Two loop analogue addressable con(Spanish language variant) control and indicating
equipment
Incorporating as modular units:
042bc/04
042bc/05
042bc/06
2434-859 Master Controller Board (MCB)
2434-862 Power Supply Unit
2434-762 Display and Key card (DKC)
2434-669 Loop processor card
4374-164 Text Membrane (English)
4374-169 Text Membrane (Spanish)
4374-170 Text Membrane (Portuguese)
2434-861 Copper network card
Scope of approval does not include the operation of the network card)
Certified with the following options with requirements from EN 54 Part 2:
Sentri4
Sentri4-PO
Sentri4-SP
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of each address point
10
Test condition
One to Four loop analogue addressable control and indicating equipment (English
language)
One to Four loop analogue addressable control and indicating equipment (Portuguese
language variant without printer module)
One to Four loop analogue addressable control and indicating equipment (Spanish
language variant without printer module)
Incorporating as modular units
2434-863
2434-710
122
042bc/07
042bc/09
042bc/10
Master controller card (M.C.C)
Loop card
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2434-831 Power supply PCB
2434-854 Backplane PCB
2434-861 Display and Key card (D.K.C)
2434-864 Terminal card
2434-565 Printer Module
4374-167 Text Membrane (English)
4374-171 Text Membrane (Spanish)
4374-172 Text Membrane (Portuguese)
2434-674 Copper network card
Scope of approval does not include the operation of the network card)
Certified with the following options with requirements from EN 54 Part 2:
7.8
7.11
8.3
9.5
10
Output to fire alarm devices
Delays to outputs
Fault signals from points
Disablement of each address point
Test condition
Thorn Security Limited, Trading as Tyco Safety Product
Hanworth Road, Sunbury on Thames, London TW16 5DB, United Kingdom
Tel: 01932 743268 • Fax: 01932 743292
E-mail: [email protected] • Website: www.Tycoemea.com
Certificate No: 018c-(cl-3) to EN54-2: 1997, EN54-4: 1997
Certificate No: 681an-(cl-1) to EN 54-2: 1997 + A1: 006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 681am-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 681ak-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 681aj-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 681ah-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 681ap-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 681af-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 681ea-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 681ac-(cl-2) to EN 54-4: 1997 + A1: 2002 + A2: 2006
Control & Indicating Equipment
Certificated Products
2 zone conventional control and indicating equipment
LPCB Ref.
No.
018c/02
Incorporating as modular units:
MZXC+
C1627
Mother board
C1628
Display board
C1631
Repeater interface (option)
Certified with the following options from EN 54: Part 2
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
4 zone conventional control and indicating equipment
018c/03
Incorporating as modular units:
C1627
Mother board
C1628
Display board
C1631
Repeater interface (option)
Certified with the following options from EN 54: Part 2
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
20 Oct 2014
123
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
MZXC+
8 zone conventional control and indicating equipment
LPCB Ref.
No.
018c/04
Incorporating as modular units:
MZXC+
C1627
Mother board
C1628
Display board
C1631
Repeater interface (option)
Certified with the following options from EN 54: Part 2
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
16 zone conventional control and indicating equipment
018c/05
Incorporating as modular units:
MZXC+
C1627
Mother board
C1628
Display board
C1631
Repeater interface (option)
Certified with the following options from EN 54: Part 2
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
32 zone conventional control and indicating equipment
018c/06
Incorporating as modular units:
MZXC+
C1627
Mother board
C1629
Display board
C1632
16 Zone expansion board
C1652
5A Power Supply board
C1631
Repeater interface (option)
Certified with the following options from EN 54: Part 2
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
8 zone conventional repeater unit
018c/R01
Incorporating as modular units:
MZXC+
C1627
Mother board
C1628
Display board
C1631
Repeater interface
16 zone conventional repeater unit
018c/R02
Incorporating as modular units:
MZXC+
C1627
Mother board
C1628
Display board
C1631
Repeater interface
32 zone conventional repeater unit
018c/R03
Incorporating as modular units:
508.031.005.xx
C1627
Mother board
C1629
Display board
C1631
Repeater interface
MZXC 4 zone conventional control and indicating equipment.
018q/03
Incorporating as modular units:
C1694 - 2605503, 4 Zone Motherboard
BAQ-35T24 Power Supply
Certified with the following options with requirements from EN 54-2:
124
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.8
7.9.1
7.12.1
7.13
10
Output to fire alarm devices
Output to fire alarm routing equipment
Dependencies on more than one alarm signal - Type A
Alarm counter
Test condition
Note:
508.031.006.xx
xx indicates the language option
Blank = Blank facia overlay
MZXC 8 zone conventional control and indicating equipment.
018q/04
Incorporating as modular units:
C1694 - 2605504, 8 Zone Motherboard
BAQ-35T24 Power Supply
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.13
Alarm counter
10
Test condition
Note:
508.031.016.xx
PSU A17
PSU A38
508.031.004.xx
xx indicates the language option
Blank = Blank facia overlay
Fire alarm repeater (mains).
Incorporating as modular units:
C1694 2605505, Repeater Motherboard
BAQ-35T24 Power Supply
Notes:
1. Compatible with 508.031.005.xx & 508.031.006.xx panels.
2. Also compatible with 508.031.005.xx & 508.031.006.xx
twin wire conventional panels on certificate 018r.
3. xx indicates the language option
Blank = Blank facia overlay
EG = English facia overlay
Addressable 17Ah Power Supply Unit
Notes:
1. The unit is not intended to supply power to Fire Alarm Control Panels
2. The maximum lead length for the fault output connection is 3m
Addressable 38Ah Power Supply Unit
Notes:
1. The unit is not intended to supply power to Fire Alarm Control Panels
2. The maximum lead length for the fault output connection is 3m
MZXC 2 zone, twin wire conventional control and indicating equipment.
018q/R01
681ac/01
681ac/02
681ae/01
Incorporating as modular units:
C1694 - 2605508, 2 Zone Twin Wire Motherboard
BAQ-35T24, Power Supply
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.13
Alarm counter
10
Test condition
Note:
508.031.005.xx
xx indicates the language option
EG = English facia overlay
MZXC 4 zone, twin wire conventional control and indicating equipment.
681ae/02
Incorporating as modular units:
C1694 - 2605509, 4 Zone Twin Wire Motherboard
BAQ-35T24, Power Supply
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.13
Alarm counter
10
Test condition
Note:
20 Oct 2014
xx indicates the language option
125
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
508.031.006.xx
LPCB Ref.
No.
EG = English facia overlay
MZXC 8 zone twin wire conventional control and indicating equipment.
681ae/03
Incorporating as modular units:
C1694 - 2605510, 8 Zone Twin Wire Motherboard
BAQ-35T24 Power Supply
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.12.1
Dependencies on more than one alarm signal - Type A
7.13
Alarm counter
10
Test condition
Note:
T2000CV
xx indicates the language option
EG = English facia overlay
3 loop Analogue Addressable Control and Indicating Equipment
Notes:
1. The following product variants are approved Finished goods No. 557.200.620, T2000CV 3 loop CIE
Finished goods No. 557.200.605, T2000-BB battery box
681ah/01
Incorporating as modular units:
OCM800
ODM800
CPU800
XLM800
FIM802
PSU830
Operator Control Module
Operator Display Module
Main CPU module
Expansion Loop Module “drives 1 or 2 additional loops”
Field Interface Module “drives 1 or 2 loops”
Power Supply Module
and as optional modular units:
ANN840
ANN880
COM820
MPM800
IOB800
FB800
40 + 40 LED Annunciator module
80 LED Annunciator module
20 way Status Command Module
Multi Purpose Interface Module
Input/Output Expansion Board
Fuse Board
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
T2000R Repeater panel is approved for use with the T2000CV Control and Indicating
Equipment (LPCB Reference 018j/R01):
Notes:
The following product variants are approved Finished goods No. 557.200.601, T2000R (AC) repeater stainless housing
Finished goods No. 557.200.604, T2000R (DC) repeater stainless housing
Finished goods No. 557.200.611, T2000R (AC) repeater mild steel housing
Finished goods No. 557.200.612, T2000R (DC) repeater mild steel housing
Incorporating as modular units:
OCM800
126
(Operator Control Module)
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
ODM800
PSU830
(Operator Display Module)
(Power Supply Module)
and as optional modular units:
T2000R
ANN840
(40 + 40 LED Annunciator)
ANN880
(80 LED Annunciator)
MPM800
(Multi Purpose Interface Module)
IOB800
(Input/Output Expansion Board)
FB800
(Fuse Board)
Repeater panel is approved for use with the T2000CV Control and Indicating Equipment
Notes:
1. The following product variants are approved Finished goods No. 557.200.601, T2000R (AC) repeater stainless housing
Finished goods No. 557.200.604, T2000R (DC) repeater stainless housing
Finished goods No. 557.200.611, T2000R (AC) repeater mild steel housing
Finished goods No. 557.200.612, T2000R (DC) repeater mild steel housing
681ah/R01
Incorporating as modular units:
OCM800 (Operator Control Module)
ODM800 (Operator Display Module)
PSU830 (Power Supply Module)
and as optional modular units:
T2000
ANN840 (40 + 40 LED Annunciator)
ANN880 (80 LED Annunciator)
MPM800 (Multi Purpose Interface Module)
IOB800 (Input/Output Expansion Board)
FB800
(Fuse Board)
2-8 loop Analogue Addressable Control and Indicating Equipment
Notes:
1. The following product variants are approved Finished goods No. 557.200.600, T2000 2-8 loop CIE, stainless housing
Finished goods No. 557.200.602, T2000-BB battery box, stainless housing
Finished goods No. 557.200.610, T2000 2-8 loop CIE, mild steel housing
Finished goods No. 557.200.605, T2000-BB battery box, mild steel housing
681aj/01
Incorporating as modular units:
OCM800
ODM800
CPU800
FIM802
PSU830
Operator Control Module
Operator Display Module
Main CPU module
Field Interface Module drives 1 or 2 loops
Power Supply Module
and as optional modular units:
XLM800
ANN840
ANN880
COM820
MPM800
IOB800
FB800
Expansion Loop Module drives 1 or 2 additional loops
40 + 40 LED Annunciator module
80 LED Annunciator module
20 way Status Command Module
Multi Purpose Interface Module
Input/Output Expansion Board
Fuse Board
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
20 Oct 2014
127
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
9.5
10
11
Disablement of addressable points
Test condition
Standardized input/output interface
T2000R Repeater panel is approved for use with the T2000CV Control and Indicating
Equipment (LPCB Reference 018j/R01):
Notes
1. The following product variants are approved Finished goods No. 557.200.601, T2000R (AC) repeater stainless housing
Finished goods No. 557.200.604, T2000R (DC) repeater stainless housing
Finished goods No. 557.200.611, T2000R (AC) repeater mild steel housing
Finished goods No. 557.200.612, T2000R (DC) repeater mild steel housing
Incorporating as modular units:
OCM800 (Operator Control Module)
ODM800 (Operator Display Module)
PSU830 (Power Supply Module)
and as optional modular units:
T2000R
ANN840 (40 + 40 LED Annunciator)
ANN880 (80 LED Annunciator)
MPM800 (Multi Purpose Interface Module)
IOB800 (Input/Output Expansion Board)
FB800
(Fuse Board)
Repeater panel is approved for use with the T2000 Control and Indicating Equipment:
Notes:
1. The following product variants are approved Finished goods No. 557.200.601, T2000R (AC) repeater stainless housing
Finished goods No. 557.200.604, T2000R (DC) repeater stainless housing
Finished goods No. 557.200.611, T2000R (AC) repeater mild steel housing
Finished goods No. 557.200.612, T2000R (DC) repeater mild steel housing
681aj/R01
Incorporating as modular units:
OCM800 (Operator Control Module)
ODM800 (Operator Display Module)
PSU830 (Power Supply Module)
and as optional modular units:
MX2
ANN840 (40 + 40 LED Annunciator)
ANN880 (80 LED Annunciator)
MPM800 (Multi Purpose Interface Module)
IOB800 (Input/Output Expansion Board)
FB800
(Fuse Board)
1-8 loop Analogue Addressable Control and Indicating Equipment
Notes:
1. The following product variants are approved Finished goods No. 557.200.203, MX2-210 1-4 loop CIE, shallow housing
Finished goods No. 557.200.205, MX2-211, 1-8 loop CIE, deep housing
681ak/01
Incorporating as modular units:
DCM800
CPU800
FIM802
PSU830
Operator Control / Display Module
Main CPU module
Field Interface Module drives 1 or 2 loops
Power Supply Module
and as optional modular units:
XLM800
ANN881
MPM800
FB800
Expansion Loop Module drives 1 or 2 additional loops
80 LED Annunciator module
Multi Purpose Interface Module
Fuse Board
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
128
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
MXR
LPCB Ref.
No.
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Repeater panel is approved for use with the MX2 Control and Indicating Equipment
Notes:
1. The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater
Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing
Finished goods No. 557.200.012, MXR repeater
Finished goods No. 557.200.017, MXR-F repeater flush housing
681ak/R01
Incorporating as modular units:
OCM800 (Operator Control Module)
ODM800 (Operator Display Module)
PSU830 (Power Supply Module)
and as optional modular units:
ANN840 (40 + 40 LED Annunciator)
ANN880 (80 LED Annunciator)
MPM800 (Multi Purpose Interface Module)
IOB800 (Input/Output Expansion Board)
FB800
(Fuse Board)
1 loop Analogue Addressable Control and Indicating Equipment
Note:
1. The following product variants are approved Finished goods No. 557.200.001, MX1000 1 loop CIE, shallow housing
Finished goods No. 557.200.005, MX-BBX battery box, shallow housing
Finished goods No. 557.200.002, MX1000 1 loop CIE, deep housing
Finished goods No. 557.200.019, MX-BBX-F battery box, flush housing
681am/01
Incorporating as modular units:
OCM800
ODM800
CPU800
FIM801
PSU830
Operator Control Module
Operator Display Module
Main CPU module
Field Interface Module
Power Supply Module
and as optional modular units:
ANN840
ANN880
COM820
MPM800
IOB800
FB800
40 + 40 LED Annunciator module
80 LED Annunciator module
20 way Status Command Module
Multi Purpose Interface Module
Input/Output Expansion Board
Fuse Board
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
20 Oct 2014
129
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.13
8.3
8.9
9.5
10
11
Alarm counter
Fault signals from points
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Standardized input/output interface
MXR Repeater panel is approved for use with the MX1000 Control and Indicating
Equipment (LPCB Reference 018f/R01):
Note:
1. The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater
Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing
Finished goods No. 557.200.012, MXR repeater
Finished goods No. 557.200.017, MXR-F repeater flush housing
Incorporating as modular units:
OCM800 (Operator Control Module)
ODM800 (Operator Display Module)
PSU830 (Power Supply Module)
and as optional modular units:
MXR
ANN840 (40 + 40 LED Annunciator)
ANN880 (80 LED Annunciator)
MPM800 (Multi Purpose Interface Module)
IOB800 (Input/Output Expansion Board)
FB800
(Fuse Board)
Repeater panel is approved for use with the MX1000 Control and Indicating Equipment
681am/R0
1
Notes:
1) The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater
Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing
Finished goods No. 557.200.012, MXR repeater
Finished goods No. 557.200.017, MXR-F repeater flush housing
Incorporating as modular units:
OCM800
ODM800
PSU830
(Operator Control Module)
(Operator Display Module)
(Power Supply Module)
and as optional modular units:
MX4000 2-8
ANN840
(40 + 40 LED Annunciator)
ANN880
(80 LED Annunciator)
MPM800
(Multi Purpose Interface Module)
IOB800
(Input/Output Expansion Board)
FB800
(Fuse Board)
2-8 loop Analogue Addressable Control and Indicating Equipment
Note:
1. The following product variants are approved Finished goods No. 557.200.003, MX4000 1-4 loop CIE, shallow housing
Finished goods No. 557.200.005, MX-BBX battery box, shallow housing
Finished goods No. 557.200.004, MX4000 1-8 loop CIE, deep housing
Finished goods No. 557.200.006, MX-DPBX battery box, deep housing (door access)
Finished goods No. 557.200.016, MX-DPBX battery box, deep housing (plain cover
access)
Finished goods No. 557.200.009, MX4000 1-4 loop, flush housing
Finished goods No. 557.200.019, MX-BBX-F battery box, flush housing
681an/01
Incorporating as modular units:
OCM800
ODM800
CPU800
FIM802
PSU830
130
Operator Control Module
Operator Display Module
Main CPU module
Field Interface Module drives 1 or 2 loops
Power Supply Module
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
and as optional modular units:
XLM800
ANN840
ANN880
COM820
MPM800
IOB800
FB800
MXR
Expansion Loop Module drives 1 or 2 additional loops
40 + 40 LED Annunciator module
80 LED Annunciator module
20 way Status Command Module
Multi Purpose Interface Module
Input/Output Expansion Board
Fuse Board
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Repeater panel is approved for use with the MX4000 Control and Indicating Equipment:
Note:
1. The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater
Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing
Finished goods No. 557.200.012, MXR repeater
Finished goods No. 557.200.017, MXR-F repeater flush housing
681an/R01
Incorporating as modular units:
OCM800 (Operator Control Module)
ODM800 (Operator Display Module)
PSU830 (Power Supply Module)
and as optional modular units:
MXR
ANN840 (40 + 40 LED Annunciator)
ANN880 (80 LED Annunciator)
MPM800 (Multi Purpose Interface Module)
IOB800 (Input/Output Expansion Board)
FB800
(Fuse Board)
Repeater panel is approved for use with the MX2 Control and Indicating Equipment
(LPCB Reference 018f/R01):
Notes:
1) The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater
Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing
Finished goods No. 557.200.012, MXR repeater
Finished goods No. 557.200.017, MXR-F repeater flush housing
681an/R01
Incorporating as modular units:
OCM800
ODM800
PSU830
(Operator Control Module)
(Operator Display Module)
(Power Supply Module)
and as optional modular units:
MZX-125
20 Oct 2014
ANN840
(40 + 40 LED Annunciator)
ANN880
(80 LED Annunciator)
MPM800
(Multi Purpose Interface Module)
IOB800
(Input/Output Expansion Board)
FB800
(Fuse Board)
Analogue Addressable Control and Indicating Equipment
681ap/01
131
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
1 loop, 16 Zone
Incorporating as modular units:
DCM816
CPU800
FIM801
PMM800
BAQ60T24
MZX-250
Operator Control / Display Module
Main CPU module
Field Interface Module
Power Supply Monitor
Power Supply
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Analogue Addressable Control and Indicating Equipment
1 loop, 32 Zone
681ap/02
Incorporating as modular units:
DCM832
CPU800
FIM802
PMM800
BAQ140T24
Operator Control / Display Module
Main CPU module
Field Interface Module (1 loop version Part No. 2605053)
Power Supply Monitor
Power Supply
and as an optional modular unit:
IOB800
MZX-251
Input/Output Expansion Board
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Analogue Addressable Control and Indicating Equipment
1 loop, 32 Zone
681ap/03
Incorporating as modular units:
DCM832
CPU800
FIM802
PMM800
BAQ140T24
132
Operator Control / Display Module
Main CPU module
Field Interface Module (1 loop version Part No. 2605053)
Power Supply Monitor
Power Supply
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
and as an optional modular unit:
IOB800
MZX-250-CH
Input/Output Expansion Board
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Analogue Addressable Control and Indicating Equipment
1 loop, 32 Zone
681ap/04
Incorporating as modular units:
DCM832
CPU800
FIM802
PMM800
FBF-CH
BAQ140T24
Operator Control / Display Module
Main CPU module
Field Interface Module (1 loop version Part No. 2605053)
Power Supply Monitor
Swiss Fire Brigade Interface
Power Supply
and as an optional modular unit:
IOB800
MZX-251-S
Input/Output Expansion Board
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Analogue Addressable Control and Indicating Equipment
1 loop, 32 Zone
681ap/05
Incorporating as modular units:
DCM832 -S
Operator Control / Display Module (Scandinavian
Fire Brigade Interface/key)
CPU800
Main CPU module
FIM802
Field Interface Module (1 loop version Part No. 2605053)
PMM800
Power Supply Monitor
BAQ140T24
Power Supply
and as an optional modular unit:
IOB800
20 Oct 2014
Input/Output Expansion Board
133
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
MZX-252
LPCB Ref.
No.
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Analogue Addressable Control and Indicating Equipment
2 loop, 32 Zone
681ap/06
Incorporating as modular units:
DCM832
CPU800
FIM802
PMM800
BAQ140T24
Operator Control / Display Module
Main CPU module
Field Interface Module
Power Supply Monitor
Power Supply
and as an optional modular unit:
IOB800
MZX-252-CH
Input/Output Expansion Board
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Analogue Addressable Control and Indicating Equipment
2 loop, 32 Zone
681ap/07
Incorporating as modular units:
DCM832
CPU800
FIM802
PMM800
FBF-CH
BAQ140T24
Operator Control / Display Module
Main CPU module
Field Interface Module
Power Supply Monitor
Swiss Fire Brigade Interface
Power Supply
and as an optional modular unit:
IOB800
Input/Output Expansion Board
Certified with the following options with requirements from EN 54 Part 2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
134
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
MZX-253
LPCB Ref.
No.
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Analogue Addressable Control and Indicating Equipment
2-4 loop, 64 Zone
Incorporating as modular units:
681ap/08
DCM864R
Operator Control / Display Module
CPU800 Main CPU module
FIM802
Field Interface Module
PMM800
Power Supply Monitor
BAQ140T24
Power Supply
and as optional modular units:
IOB800
Input/Output Expansion Board
PMM840
Power Supply Monitor
XLM800
Loop Expander Board
MZX-254
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Analogue Addressable Control and Indicating Equipment
2-4 loop, 240 Zone
Incorporating as modular units:
681ap/09
DCM832 Operator Control / Display Module
CPU800
Main CPU module
FIM802
Field Interface Module
PMM800
Power Supply Monitor
BAQ140T24
Power Supply
and as optional modular units:
IOB800
Input/Output Expansion Board
PMM840
Power Supply Monitor
XLM800
Loop Expander Board
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
20 Oct 2014
135
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
MZX-254-S
LPCB Ref.
No.
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Analogue Addressable Control and Indicating Equipment
2-4 loop, 240 Zone
Incorporating as modular units:
DCM832-S
Interface/key)
CPU800
FIM802
PMM800
BAQ140T24
681ap/10
Operator Control / Display Module (Scandinavian Fire Brigade
Main CPU module
Field Interface Module
Power Supply Monitor
Power Supply
and as optional modular units:
IOB800
Input/Output Expansion Board
PMM840
Power Supply Monitor
XLM800
Loop Expander Board
MZX-254-CH
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
Analogue Addressable Control and Indicating Equipment
2-4 loop, 240 Zone
Incorporating as modular units:
DCM832
CPU800
FIM802
PMM800
FBF-CH
BAQ140T24
681ap/11
Operator Control / Display Module
Main CPU module
Field Interface Module
Power Supply Monitor
Swiss Fire Brigade Interface
Power Supply
and as optional modular units:
IOB800
Input/Output Expansion Board
PMM840
Power Supply Monitor
XLM800
Loop Expander Board
Certified with the following options with requirements from EN 54-2:
7.8
Output to fire alarm devices
7.9.1
Output to fire alarm routing equipment
7.9.2
Alarm confirmation input from fire alarm routing equipment
7.10.1
Outputs to fire protection equipment (Type A)
7.10.2
Outputs to fire protection equipment (Type B)
7.10.3
Outputs to fire protection equipment (Type C)
7.10.4
Fault monitoring of fire protection equipment
7.11
Delays to outputs
7.12.1
Dependencies on more than one alarm signal (Type A dependency)
7.12.2
Dependencies on more than one alarm signal (Type B dependency)
7.12.3
Dependencies on more than one alarm signal (Type C dependency)
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault warning routing equipment
136
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
MZX-16-R
LPCB Ref.
No.
9.5
Disablement of addressable points
10
Test condition
11
Standardized input/output interface
16 Zone Repeater Panel, is approved for use with the MZX-125 Control and Indicating
Equipment
681ap/R01
Incorporating as modular units:
MZX-32-R
DCM816 Operator Control / Display Module
PMM800 Power Supply Monitor
BAQ60T24
Power Supply
32 Zone Repeater Panel, is approved for use with the MZX-250, MZX-250-CH, MZX-251,
MZX-252 & MZX-252-CH Control and Indicating Equipment
681ap/R02
Incorporating as modular units:
MZX-32-SR
DCM832 Operator Control / Display Module
PMM800 Power Supply Monitor
BAQ60T24
Power Supply
32 Zone Repeater Panel, is approved for use with the MZX-251-S Control and Indicating
Equipment
681ap/R03
Incorporating as modular units:
MZX-64-DR
MZX-DR
MZX-SDR
MZX-CHDR
DCM832-S
Operator Control / Display Module
PMM800 Power Supply Monitor
BAQ60T24
Power Supply
64 Zone Repeater Panel, is approved for use with the MZX-253 Control and Indicating
Equipment
Incorporating as modular units:
DCM832R
Operator Control / Display Module
PMM805
Power Supply Monitor (24 VDC)
240 Zone Repeater Panel, is approved for use with the MZX-254 Control and Indicating
Equipment
Incorporating as modular units:
DCM832 Operator Control / Display Module
PMM805
Power Supply Monitor (24 VDC)
240 Zone Repeater Panel, is approved for use with the MZX254-S Control and Indicating
Equipment
Incorporating as modular units:
DCM832 -S
Operator Control / Display Module (Scandinavian Fire Brigade
Interface/key)
PMM805
Power Supply Monitor (24 VDC)
240 Zone Repeater Panel, is approved for use with the MZX-254-CH Control and
Indicating Equipment
681ap/R04
681ap/R05
681ap/R06
681ap/R07
Incorporating as modular units:
DCM832 Operator Control / Display Module
FBF-CH
Swiss Fire Brigade Interface
PMM805
Power Supply Monitor (24 VDC)
UTC CCS Manufacturing Polska, Sp. Zo.o
ul. Kolejowa 24, Ropczyce 39100, Poland
E-mail: [email protected]
Certificate No: 1199a-(cl-1) to EN 54-2:1997 + A1:2006 , EN54-4:1997+ A1:2002 +A2:2006 and EN54-21:2006
Certificate No: 1199b-(cl-1) to EN54-2:1997+A1:2006 EN54-2:1997+A1:2006 + A2:2006
Certificate No: 1199c/01 to EN 54-4:1998 EN-54-2:1998
Control and indicating equipment
Certificated Products
KFP-AF1, KFP-AF1-S
20 Oct 2014
Intelligent Analogue Addressable Fire Panel with user interface - 1 loop
LPCB Ref.
No.
1199a/05
137
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Intelligent Analogue Addressable Fire Panel with user interface - 1 loop small cabinet
Incorporating the following units:
2010-2F1-MB
KFP-A-UI
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
ZP2-F1-S, ZP2-F1
KFP-A-ZI-20
(20 Zone) (Large cabinet variant only)
KFP-A-ZI-40
(40 Zone) (Large cabinet variant only)
KFP-A-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
KFP-A-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2 UK
mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PIB-8O
Peripheral Interface Board 8 outputs (Large cabinet variant only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet
variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface - 1 loop
Intelligent Analogue Addressable Fire Panel with user interface - 1 loop small cabinet
1199a/05
Incorporating the following units:
2010-2F1-MB
ZP2-UI
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
2X-F1-SC, 2X-F1-SC-S
ZP2-ZI-20
(20 Zone) (Large cabinet variant only)
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
ZP2-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PIB-8O
Peripheral Interface Board 8 outputs (Large cabinet variant
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
ZP2-D-TP
Translucent door option for large cabinet*
ZP2-D-TP-S
Translucent door option for small cabinet*
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 1 loop (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 1 loop small cabinet (Scandinavia)
1199a/06
Incorporating the following units:
2010-2F1-MB
Main control board
2X-UI-SC
User interface control board
2010-2-PS-40 4A
Power Supply
And as optional modules:
2X-ZI-20
2X-ZI-40
2010-2-NB
2X-LB
2010-2-232-KIT
2010-SK
2010-2-PS-C2
2010-2-PS-C2-S
138
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
Network card
Loop Board (Large cabinet variant only)
Interface board for external printer
Scandinavian key and lock assembly
UK mains cable for large cabinet
UK mains cable for small cabinet
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
KFP-AF1-SC, KFP-AF1SC-S
LPCB Ref.
No.
2010-2-PIB-8O
Peripheral Interface Board 8 outputs (Large cabinet variant
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet
variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 1 loop (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 1 loop small cabinet (Scandinavia)
1199a/06
Incorporating the following units:
2010-2F1-MB
KFP-A-UI-SC
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
KFP-A-ZI-20
KFP-A-ZI-40
2010-2-NB
KFP-A-LB
2010-2-232-KIT
2010-SK
2010-2-PS-C2
2010-2-PS-C2-S
2010-2-PIB-8O
2010-2-PIB-8I
only)
2010-2-PIB-8I8O
ZP2-F1-SC, ZP2-F1-SC-S
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
Network card
Loop Board (Large cabinet variant only)
Interface board for external printer
Scandinavian key and lock assembly
UK mains cable for large cabinet
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant only)
Peripheral Interface Board 8 inputs (Large cabinet variant
Peripheral Interface Board 8 outputs and 8 inputs (Large
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 1 loop (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 1 loop small cabinet (Scandinavia)
1199a/06
Incorporating the following units:
2010-2F1-MB
ZP2-UI-SC
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
2X-F1-FB2-S, 2X-F1-FB2
ZP2-ZI-20
(20 Zone) (Large cabinet variant only)
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
2010-2-NB
Network card
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 1 loop
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 1 loop small cabinet
1199a/07
Incorporating the following units:
2010-2F1-MB
2X-UI-FB2
20 Oct 2014
Main control board
User interface control board
139
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2010-2-PS-40 4A
Power Supply
And as optional modules:
ZP2-F1-FB2, ZP2-F1-FB2S
2X-ZI-20
(20 Zone) (Large cabinet variant only)
2X-ZI-40
(40 Zone) (Large cabinet variant only)
2X-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
2X-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PIB
Peripheral Interface Board (Germany) (Large cabinet variant only)
2010-2-PIB-8O
Peripheral Interface Board 8 outputs (Large cabinet variant only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet
variant only)
ADP-N3E-U
IFAM interface card (master) (Large cabinet variant only)
ADP-N3S
interface card (slave) (Large cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2X-D-FB2-TP
Translucent door option for large cabinet*
2X-D-FB2-TP-S
Translucent door option for small cabinet*
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 1 loop
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 1 loop small cabinet
1199a/07
Incorporating the following units:
2010-2F1-MB
ZP2-UI-FB2
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
2X-E1, 2X-E1-S
ZP2-ZI-20
(20 Zone) (Large cabinet variant only)
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
ZP2-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB
only)
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I
only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
ADP-N3E-U IFAM
interface card (master) (Large cabinet variant only)
ADP-N3S
interface card (slave) (Large cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
ZP2-D-FB2-TP
Translucent door option for large cabinet*
ZP2-D-FB2-TP-S
Translucent door option for small cabinet*
Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire
brigade controls - 1 loop
Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire
brigade controls - 1 loop small
Cabinet
1199a/08
Incorporating the following units:
2010-2F1-MB
2X-UI-E
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
140
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2X-ZI-20
2X-ZI-40
2X-ZI-24-S
2010-2-NB
2X-LB Loop Board
2010-2-232-KIT
2010-2-PS-C2
2010-2-PS-C2-S
2010-2-PIB-8O
only)
2010-2-PIB-8I
only)
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
2X-D-E-TP
2X-D-E-TP-S
2010-FS-EOL
KFP-AE1, KFP-AE1-S
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
(24 Zone) (Small cabinet variant only)
Network card
(Large cabinet variant only)
Interface board for external printer
UK mains cable for large cabinet
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
Peripheral Interface Board 8 inputs (Large cabinet variant
Peripheral Interface Board 8 outputs and 8 inputs (Large
with ATS7310 (GSM module)
Translucent door option for large cabinet*
Translucent door option for small cabinet*
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire
brigade controls - 1 loop
Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire
brigade controls - 1 loop small cabinet
1199a/08
Incorporating the following units:
2010-2F1-MB
KFP-A-UI-E
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
KFP-A-ZI-20
KFP-A-ZI-40
KFP-A-ZI-24-S
2010-2-NB
KFP-A-LB
2010-2-232-KIT
2010-2-PS-C2
2010-2-PS-C2-S
2010-2-PIB-8O
only)
2010-2-PIB-8I
only)
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
2010-FS-EOL
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
(24 Zone) (Small cabinet variant only)
Network card
Loop Board (Large cabinet variant only)
Interface board for external printer
UK mains cable for large cabinet
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
Peripheral Interface Board 8 inputs (Large cabinet variant
Peripheral Interface Board 8 outputs and 8 inputs (Large
with ATS7310 (GSM module)
Fault Supervision End of Line unit
The above fire panels are certified with the following options with requirements from EN
54-2:
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment (not available on
KFP-A-F1 and KFP-A-F1-S)
7.9.2
Alarm confirmation input from fire alarm routing equipment
(not available on KFP-A-F1 and KFP-A-F1-S)
7.10
Output to fire protection equipment - Type A,B and C (not
available on KFP-A-F1 and KFP-A-F1-S)
7.11
Delays to outputs
7.12
Dependencies on more than one alarm signal (Type A, B and
C)
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Notes:
This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
1. Available with the following language kit options: -01 Dutch (NL) The Netherlands-02
20 Oct 2014
141
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
ZP2-E1, ZP2-E1-S
LPCB Ref.
No.
French (FR) France -03 English (UK) United
Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06 Swedish
Sweden-07 Danish (DK) Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU) German (Austria)-14 Greek
Greece-15 Arabic Middle East-17 English (US) United States of America-18 Polish
Poland-19 Turkish Turkey-20 Czech Czech
Republic-21 Portuguese Portugal-22 Hungarian Hungary -23 Danish (IC) Iceland-24
Slovakian Slovak Republic-25 Russian Russia27 Lithuanian Lithuania-28 Finnish Finland-29 German (SW) Switzerland-30 Estonian
Estonia-31 Latvian Latvia-32 French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40 Bulgarian Bulgaria-41
Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO)
Romania-46 German (Int) International German-48
Croatian Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71
Catalan Catalunia (Spain)-80 Chinese
China-99 English (Int) International English
2. Scope of the approval does not indicate the operation of the networkfunctionality
Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire
brigade controls - 1 loop
Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire
brigade controls - 1 loop small cabinet
1199a/08
Incorporating the following units:
2010-2F1-MB
ZP2-UI-E
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
ZP2-ZI-20
(20 Zone) (Large cabinet variant only)
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
ZP2-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PIB-8O
Peripheral Interface Board 8 outputs (Large cabinet variant
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
ZP2-D-E-TP
Translucent door option for large cabinet*
ZP2-D-E-TP-S
Translucent door option for small cabinet*
The above fire panels are certified with the following options with requirements from EN
54-2:
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment (not available on ZP2F1 and ZP2-F1-S)
7.9.2
Alarm confirmation input from fire alarm routing equipment
(not available on ZP2-F1 and ZP2-F1-S)
7.10
Output to fire protection equipment - Type A,B and C (not
available on ZP2-F1 and ZP2-F1-S)
7.11
Delays to outputs
7.12
Dependencies on more than one alarm signal (Type A, B and
C)
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Notes:
This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
142
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
2X-F1-SCFB-S, 2X-F1SCFB
LPCB Ref.
No.
1. Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04 German (DE) Germany-05
Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08 English (AU)
Australia-09 Spanish Spain-10 Italian Italy-11
Dutch (BE) Belgium-12 Irish Ireland-13 German (AU) German (Austria)-14 Greek
Greece-15 Arabic Middle East-17 English (US)
United States of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic21 Portuguese Portugal-22 Hungarian
Hungary
-23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian
Lithuania-28 Finnish Finland-29 German
(SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33
French (SW) Switzerland-34 Italian (SW)
Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian
Belarus-43 Ukrainian Ukraine-44 Serbian
Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48 Croatian
Croatia-49 Macedonian Macedonia-50
Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99
English (Int) International English
2. Scope of the approval does not indicate the operation of the network functionality
*The translucent door does not meet EN54-2 access level 1 requirements. To meet
EN54-2 requirements with the door fitted the
following is also required:
3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2
part 7.3)
4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to
meet requirements of EN54-2 part 7.11)
Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade
controls - 1 loop (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade
controls - 1 loop small cabinet (Scandinavia)
1199a/09
Incorporating the following units:
2010-2F1-MB
Main control board
2X-UI-SCFB
User interface control board
2010-2-PS-40 4A
Power Supply
And as optional modules:
2X-ZI-20
2X-ZI-40
2010-2-NB
2X-LB
2010-2-232-KIT
2010-SK
2010-2-PS-C2
2010-2-PS-C2-S
2010-2-PIB-8O
2010-2-PIB-8I
2010-2-PIB-8I8O
variant only)
2010-2-DACT
2010-FS-EOL
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
Network card
Loop Board (Large cabinet variant only)
Interface board for external printer
Scandinavian key and lock assembly
UK mains cable for large cabinet
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant only)
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet
with ATS7310 (GSM module)
Fault Supervision End of Line unit
The above fire panels are certified with the following options with requirements from EN
54-2:
7.8
7.9.1
Output to fire alarm device(s)
Output to fire alarm routing equipment (not available on 2X-
F1 and 2X-F1-S)
7.9.2
Alarm confirmation input from fire alarm routing equipment
(not available on 2X-F1 and 2X-F1-S)
7.10
Output to fire protection equipment - Type A,B
and C (notavailable on 2X-F1 and 2X-F1-S)
7.11
Delays to outputs
7.12
Dependencies on more than one alarm signal (Type A, B and C)
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
20 Oct 2014
143
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
10
KFP-AF1-SCFB, KFP-AF1SCFB-S
Test condition
Notes:
This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
2. Available with the following language kit options: -01 Dutch (NL) The Netherlands, -02
French (FR), -03 English (UK) United
Kingdom and Ireland, -04 German (DE) -05 Norwegian, -06 Swedish, -07 Danish (DK), 08 English (AU) Australia, -09
Spanish, -10 Italian, -11 Dutch (BE) Belgium, -12 Irish, -13 German (AU) (Austria), -14
Greek, -15 Arabic, -17 English (US)
United States of America, -18 Polish, -19 Turkish, -20 Czech Republic, -21 Portuguese, 22 Hungarian, -23 Danish (IC)
Iceland, -24 Slovakian, -25 Russian, -27 Lithuanian, -28 Finnish, -29 German (SW)
Switzerland, -30 Estonian,-31 Latvian, 32 French (BE) Belgium, -33 French (SW) Switzerland, -34 Italian (SW) Switzerland, -36
French (Int) International, -40
Bulgarian, -41 Belarusian, -43 Ukrainian, -44 Serbian, -45 Romanian (RO), -46 German
(Int) International, -48 Croatian, -49
Macedonian, -50 Slovenian, -51 Hebrew, -71 Catalan, -80 Chinese, -99 English (Int)
International English
2. Scope of the approval does not indicate the operation of the network functionality
*The translucent door does not meet EN54-2 access level 1 requirements. To meet
EN54-2 requirements with the door fitted the
following is also required:
3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2
part 7.3)
4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to
meet requirements of EN54-2 part
7.11)
Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade
controls - 1 loop (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 2 loop with printer
1199a/09
Incorporating the following units:
2010-2F1-MB
KFP-A-UI-SCFB
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
ZP2-F1-SCFB, ZP2-F1SCFB-S
KFP-A-ZI-20
(20 Zone) (Large cabinet variant only)
KFP-A-ZI-40
(40 Zone) (Large cabinet variant only)
2010-2-NB
Network card
KFP-A-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade
controls - 1 loop (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade
controls - 1 loop small cabinet (Scandinavia)
1199a/09
Incorporating the following units:
2010-2F1-MB
ZP2-UI-SCFB
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
ZP2-ZI-20
144
(20 Zone) (Large cabinet variant only)
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
2X-F2, 2X-F2-PRT, 2X-F2S
LPCB Ref.
No.
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
2010-2-NB
Network card
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface - 2 loop
Intelligent Analogue Addressable Fire Panel with user interface - 2 loop with printer
Intelligent Analogue Addressable Fire Panel with user interface - 2 loop small cabinet
1199a/10
Incorporating the following units:
2010-2F2-MB
2X-UI User
2010-2-PS-40 4A
Main control board
interface control board
Power Supply
And as optional modules:
KFP-AF2,KFP-AF2-PRT,
KFP-AF2-S
2X-ZI-20
(20 Zone) (Large cabinet variant only)
2X-ZI-40
(40 Zone) (Large cabinet variant only)
2X-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
2X-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PRT
Door mounted printer module (2X-F2-PRT variant only)
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant
only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2X-D-TP
Translucent door option for large cabinet* (2X-F2 variant
only)
2X-D-TP-S
Translucent door option for small cabinet* (2X-F2-S variant
only)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface - 2 loop
Intelligent Analogue Addressable Fire Panel with user interface - 2 loop with printer
Intelligent Analogue Addressable Fire Panel with user interface - 2 loop small cabinet
1199a/10
Incorporating the following units:
2010-2F2-MB
KFP-A-UI
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
KFP-A-ZI-20
KFP-A-ZI-40
KFP-A-ZI-24-S
2010-2-NB
KFP-A-LB
2010-2-232-KIT
2010-2-PS-C2
2010-2-PS-C2-S
2010-2-PRT
2010-2-PIB-8O
only)
2010-2-PIB-8I
only)
20 Oct 2014
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
(24 Zone) (Small cabinet variant only)
Network card
Loop Board (Large cabinet variant only)
Interface board for external printer
UK mains cable for large cabinet
UK mains cable for small cabinet
Door mounted printer module (KFP-A-F2-PRT variant only)
Peripheral Interface Board 8 outputs (Large cabinet variant
Peripheral Interface Board 8 inputs (Large cabinet variant
145
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
ZP2-F2, ZP2-F2-PRT,
ZP2-F2-S
LPCB Ref.
No.
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface - 2 loop
Intelligent Analogue Addressable Fire Panel with user interface - 2 loop with printer
Intelligent Analogue Addressable Fire Panel with user interface - 2 loop small cabinet
1199a/10
Incorporating the following units:
2010-2F2-MB
ZP2-UI
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
2X-F2-SC, 2X-F2-SC-S
ZP2-ZI-20
(20 Zone) (Large cabinet variant only)
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
ZP2-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PRT
Door mounted printer module (ZP2-F2-PRT variant only)
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
ZP2-D-TP
Translucent door option for large cabinet* (ZP2-F2 variant only)
ZP2-D-TP-S
Translucent door option for small cabinet* (ZP2-F2-S variant
only)
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
2 loop (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
2 loop small cabinet (Scandinavia)
1199a/11
Incorporating the following units:
2010-2F2-MB
Main control board
2X-UI-SC
User interface control board
2010-2-PS-40 4A
Power Supply
And as optional modules:
KFP-AF2-SC, KFP-AF2SC-S
2X-ZI-20
(20 Zone) (Large cabinet variant only)
2X-ZI-40
(40 Zone) (Large cabinet variant only)
2010-2-NB
Network card
2X-LB Loop Board
(Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I
only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
2 loop (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
2 loop small cabinet (Scandinavia)
1199a/11
Incorporating the following units:
2010-2F2-MB
KFP-A-UI-SC
146
Main control board
User interface control board
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2010-2-PS-40 4A
Power Supply
And as optional modules:
ZP2-F2-SC, ZP2-F2-SC-S
KFP-A-ZI-20
(20 Zone) (Large cabinet variant only)
KFP-A-ZI-40
(40 Zone) (Large cabinet variant only)
2010-2-NB
Network card
KFP-A-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I
only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
2 loop (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
2 loop small cabinet (Scandinavia)
1199a/11
Incorporating the following units:
2010-2F2-MB
ZP2-UI-SC
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
2X-F2-FB2-PRT, 2X-F2FB2, 2X-F2-FB2-S
ZP2-ZI-20
(20 Zone) (Large cabinet variant only)
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
2010-2-NB
Network card
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I
only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet
variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 2 loop
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 2 loop with printer
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 2 loop small cabinet
1199a/12
Incorporating the following units:
2010-2F2-MB
2X-UI-FB2
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
2X-ZI-20
2X-ZI-40
2X-ZI-24-S
2010-2-NB
2X-LB
2010-2-232-KIT
2010-2-PS-C2
2010-2-PS-C2-S
20 Oct 2014
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
(24 Zone) (Small cabinet variant only)
Network card
Loop Board (Large cabinet variant only)
Interface board for external printer
UK mains cable for large cabinet
UK mains cable for small cabinet
147
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
KFP-A-F2FB2-PRT KFPAF2-FB2-S KFP-AF2-FB2
LPCB Ref.
No.
2010-2-PRT
Door mounted printer module (2X-F2-FB2-PRT variant only)
Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB
only)
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
ADP-N3E-U
(Large cabinet variant only)
ADP-N3S
(Large cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2X-D-FB2-TP
Translucent door option for large cabinet* (2X-F2-FB2 variant
only)
2X-D-FB2-TP-S
Translucent door option for large cabinet* (2X-F2-FB2-S
variant only)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 2 loop
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 2 loop with printer
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 2 loop small cabinet
1199a/12
Incorporating the following units:
2010-2F2-MB
KFP-A-UI-FB2
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
ZP2-F2-FB2, ZP2-F2-FB2
PRT, ZP2F2-FB2-S
KFP-A-ZI-20
(20 Zone) (Large cabinet variant only)
KFP-A-ZI-40
(40 Zone) (Large cabinet variant only)
KFP-A-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
KFP-A-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PRT
Door mounted printer module (KFP-A-F2-FB2-PRT variant
only)
Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB
only)
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I
only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
ADP-N3E-U
(Large cabinet variant only)
ADP-N3S
(Large cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 2 loop
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 2 loop with printer
Intelligent Analogue Addressable Fire Panel with user interface with fire brigade controls
- 2 loop small cabinet
1199a/12
Incorporating the following units:
2010-2F2-MB
ZP2-UI-FB2
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
ZP2-ZI-20
ZP2-ZI-40
ZP2-ZI-24-S
2010-2-NB
148
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
(24 Zone) (Small cabinet variant only)
Network card
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
2X-F2-SCFB, 2X-F2SCFB-S
LPCB Ref.
No.
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PRT
Door mounted printer module (ZP2-F2-FB2-PRT variant only)
Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB
only)
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large
cabinet variant only)
ADP-N3E-U
(Large cabinet variant only)
ADP-N3S
(Large cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
ZP2-D-FB2-TP
Translucent door option for large cabinet* (ZP2-F2-FB2 variant
only)
ZP2-D-FB2-TP-S
Translucent door option for large cabinet* (ZP2-F2-FB2-S variant
only)
Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade
controls - 2 loop (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade
controls 2 loop small cabinet (Scandinavia)
1199a/13
Incorporating the following units:
2010-2F2-MB
2X-UI-SCFB
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
KFP-AF2-SCFB-S, KFPAF2-SCFB
2X-ZI-20
(20 Zone) (Large cabinet variant only)
2X-ZI-40
(40 Zone) (Large cabinet variant only)
2010-2-NB
Network card
2X-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PIB-8O
Peripheral Interface Board 8 outputs (Large cabinet variant
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade
controls - 2 loop (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade
controls - 2 loop small cabinet (Scandinavia)
1199a/13
Incorporating the following units:
2010-2F2-MB
KFP-A-UI-SCFB
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
KFP-A-ZI-20
KFP-A-ZI-40
2010-2-NB
KFP-A-LB
2010-2-232-KIT
2010-SK
2010-2-PS-C2
2010-2-PS-C2-S
2010-2-PRT
only)
2010-2-PIB-8O
20 Oct 2014
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
Network card
Loop Board (Large cabinet variant only)
Interface board for external printer
Scandinavian key and lock assembly
UK mains cable for large cabinet
UK mains cable for small cabinet
Door mounted printer module (KFP-A-F2-SCFB-PRT variant
Peripheral Interface Board 8 outputs (Large cabinet variant
149
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
ZP2-F2-SCFB-S,ZP2-F2SCFB-PRT,ZP2-F2-SCFB
LPCB Ref.
No.
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade
controls - 2 loop (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade
controls - 2 loop with printer (Scandinavia)
Intelligent Analogue Addressable Fire Panel with user interface with SS3654 fire brigade
controls - 2 loop small cabinet (Scandinavia)
1199a/13
Incorporating the following units:
2010-2F2-MB
ZP2-UI-SCFB
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
2X-E2, 2X-E2-S
ZP2-ZI-20
(20 Zone) (Large cabinet variant only)
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
2010-2-NB
Network card
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PRT
Door mounted printer module (ZP2-F2-SCFB-PRT variant
only)
2010-2-PIB-8O
Peripheral Interface Board 8 outputs (Large cabinet variant
only)
Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I
only)
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire
brigade controls - 2 loop
Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire
brigade controls 2 loop small cabinet
1199a/14
Incorporating the following units:
2010-2F2-MB
2X-UI-E
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
2X-ZI-20
2X-ZI-40
2X-ZI-24-S
2010-2-NB
2X-LB
2010-2-232-KIT
2010-2-PS-C2
2010-2-PS-C2-S
2010-2-PIB-8O
only)
2010-2-PIB-8I
only)
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
2X-D-E-TP
2X-D-E-TP-S
2010-FS-EOL
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
(24 Zone) (Small cabinet variant only)
Network card
Loop Board (Large cabinet variant only)
Interface board for external printer
UK mains cable for large cabinet
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
Peripheral Interface Board 8 inputs (Large cabinet variant
Peripheral Interface Board 8 outputs and 8 inputs (Large
with ATS7310 (GSM module)
Translucent door option for large cabinet*
Translucent door option for large cabinet*
Fault Supervision End of Line unit
The above fire panels are certified with the following options with requirements from EN
150
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
54-2:
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment (not available on 2XF2, 2X-F2-PRT and 2X-F2-S)
7.9.2
Alarm confirmation input from fire alarm routing equipment
(not available on 2X-F2, 2X-F2-PRT and 2X-F2-S)
7.10
Output to fire protection equipment - Type A,B and C (not
available on 2X-F2, 2X-F2-PRT and 2X-F2-S)
7.11
Delays to outputs
7.12
Dependencies on more than one alarm signal (Type A, B and
C)
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Notes:
This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13
.
1.Available with the following language kit options: This product approval does not
constitute compliance with the fire detection and alarm systems requirements of EN 5413.
1. Available with the following language kits:-01 Dutch (NL) The Netherlands-02 French
(FR) France -03 English (UK)
United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06
Swedish Sweden-07 Danish (DK)
Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE)
Belgium-12 Irish Ireland-13 German
(AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United
States of America-18 Polish
Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian Hungary-23 Danish (IC)
Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian Lithuania-28
Finnish Finland-29 German (SW)
Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE) Belgium-33 French
(SW) Switzerland-34 Italian (SW)
Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41 Belarusian
Belarus-43 Ukrainian Ukraine-44
Serbian Serbia-45 Romanian (RO) Romania-46 German (Int) International German-48
Croatian Croatia-49 Macedonian
Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80
Chinese China-99 English (Int)
International English2.Scope of the approval does not indicate the operation of the
network functionality
KFP-AE2, KFP-AE2-S
*The translucent door does not meet EN54-2 access level 1 requirements. To meet
EN54-2 requirements with the door fitted the following is also required:
3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2
part 7.3)
4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to
meet
requirements of EN54-2 part 7.11)
Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire
brigade controls - 2 loop
Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire
brigade controls - 2 loop small cabinet
1199a/14
Incorporating the following units:
2010-2F2-MB
KFP-A-UI-E
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
KFP-A-ZI-20
KFP-A-ZI-40
KFP-A-ZI-24-S
2010-2-NB
20 Oct 2014
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
(24 Zone) (Small cabinet variant only)
Network card
151
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
KFP-A-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PIB-8O
Peripheral Interface Board 8 outputs (Large cabinet variant
only)
Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I
only)
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
The above fire panels are certified with the following options with requirements from EN
54-2:
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment (not available on KFPAF2, KFP-AF2-PRT and KFP-AF2-S)
7.9.2
Alarm confirmation input from fire alarm routing equipment
(not available on KFP-A-F2, KFP-AF2-PRT and KFP-AF2-S)
7.10
Output to fire protection equipment - Type A,B and C (not
available on KFP-A-F2, KFP-A-F2-PRT and KFP-A-F2-S)
7.11
Delays to outputs
7.12
Dependencies on more than one alarm signal (Type A, B and
C)
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
ZP2-E2, ZP2-E2-S
Notes:
This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
1. Available with the following language kit options: -01 Dutch (NL) The Netherlands-02
French (FR) France -03 English (UK)
United Kingdom and Ireland -04 German (DE) Germany-05 Norwegian Norway-06
Swedish Sweden-07 Danish (DK)
Denmark-08 English (AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE)
Belgium-12 Irish Ireland-13 German
(AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United
States of America-18 Polish
Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian Hungary
-23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian
Lithuania-28 Finnish Finland-29
German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE)
Belgium-33 French (SW) Switzerland34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41
Belarusian Belarus-43
Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int)
International German-48 Croatian
Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan
Catalunia (Spain)-80 Chinese
China-99 English (Int) International English
2. Scope of the approval does not indicate the operation of the network functionality
Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire
brigade controls - 2 loop
Intelligent Analogue Addressable Fire and Evacuation Panel with user interface with fire
brigade controls - 2 loop small cabinet
1199a/14
Incorporating the following units:
2010-2F2-MB
Main control board
ZP2-UI-E
User interface control board
2010-2-PS-40 4A
Power Supply
And as optional modules:
ZP2-ZI-20
(20 Zone) (Large cabinet variant only)
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
ZP2-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
152
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
ZP2-D-E-TP
Translucent door option for large cabinet*
ZP2-D-E-TP-S
Translucent door option for large cabinet*
The above fire panels are certified with the following options with requirements from EN
54-2:
7.8
Output to fire alarm device(s)
7.9.1
Output to fire alarm routing equipment (not available on ZP2F2, ZP2-F2-PRT and ZP2-F2-S)
7.9.2
Alarm confirmation input from fire alarm routing equipment
(not available on ZP2-F2, ZP2-F2-PRT and ZP2-F2-S)
7.10
Output to fire protection equipment - Type A,B and C (not
available on ZP2-F2, ZP2-F2-PRT and ZP2-F2-S)
7.11
Delays to outputs
7.12
Dependencies on more than one alarm signal (Type A, B and
C)
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
2X-FR, 2X-FR-S
Notes:
This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
1. Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04 German (DE)
Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK) Denmark-08
English (AU) Australia-09 Spanish
Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland-13 German (AU) German
(Austria)-14 Greek Greece-15
Arabic Middle East-17 English (US) United States of America-18 Polish Poland-19
Turkish Turkey-20 Czech Czech
Republic-21 Portuguese Portugal-22 Hungarian Hungary
-23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian
Lithuania-28 Finnish Finland-29
German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32 French (BE)
Belgium-33 French (SW) Switzerland34 Italian (SW) Switzerland-36 French (Int) International French-40 Bulgarian Bulgaria-41
Belarusian Belarus-43
Ukrainian Ukraine-44 Serbian Serbia-45 Romanian (RO) Romania-46 German (Int)
International German-48 Croatian
Croatia-49 Macedonian Macedonia-50 Slovenian Slovenia-51 Hebrew Israel-71 Catalan
Catalunia (Spain)-80 Chinese
China-99 English (Int) International English
2. Scope of the approval does not indicate the operation of the network functionality
*The translucent door does not meet EN54-2 access level 1 requirements. To meet
EN54-2 requirements with the door fitted the
following is also required:
3. A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2
part 7.3)
4. A MCP (without program delay) fitted beside the panel to allow overriding of delays (to
meet requirements of EN54-2 part 7.11)
Intelligent Analogue Addressable Fire Panel Repeater
Intelligent Analogue Addressable Fire Panel Repeater small cabinet
1199a/R01
Incorporating the following units:
2010-2FR-MB
2X-UI
20 Oct 2014
Main control board
User interface control board
153
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2010-2-PS-40 4A
Power Supply
And as optional modules:
KFP-A-FR, KFP-A-FR-S
2X-ZI-20
(20 Zone) (Large cabinet variant only)
2X-ZI-40
(40 Zone) (Large cabinet variant only)
2X-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
2X-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PIB-8O
Peripheral Interface Board 8 outputs (Large cabinet variant only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet
variant only)
2010-2-DACT
with ATS7310 (GSM module)
2X-D-TP
Translucent door option for large cabinet*
2X-D-TP-S
Translucent door option for small cabinet*
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel Repeater
Intelligent Analogue Addressable Fire Panel Repeater small cabinet
1199a/R01
Incorporating the following units:
2010-2FR-MB
KFP-A-UI
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
ZP2-FR, ZP2-FR-S
KFP-A-ZI-20
(20 Zone) (Large cabinet variant only)
KFP-A-ZI-40
(40 Zone) (Large cabinet variant only)
KFP-A-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
KFP-A-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I
only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel Repeater
Intelligent Analogue Addressable Fire Panel Repeater small cabinet
1199a/R01
Incorporating the following units:
2010-2FR-MB
ZP2-UI
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
ZP2-ZI-20
(20 Zone) (Large cabinet variant only)
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
ZP2-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
154
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
2X-FR-FB2, 2X-FR-FB2-S
LPCB Ref.
No.
2010-FS-EOL
Fault Supervision End of Line unit
ZP2-D-TP
Translucent door option for large cabinet*
ZP2-D-TP-S
Translucent door option for small cabinet*
Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls
Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small
cabinet
1199a/R02
Incorporating the following units:
2010-2FR-MB
Main control board
2X-UI-FB2
User interface control board
2010-2-PS-40 4A
Power Supply
And as optional modules:
KFP-A-FR-FB2-S, KFP-AFR-FB2
2X-ZI-20
(20 Zone) (Large cabinet variant only)
2X-ZI-40
(40 Zone) (Large cabinet variant only)
2X-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
2X-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PIB
Peripheral Interface Board (Germany) (Large cabinet variant only)
2010-2-PIB-8O
Peripheral Interface Board 8 outputs (Large cabinet variant only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet
variant only)
ADP-N3E-U IFAM
interface card (master) (Large cabinet variant only)
ADP-N3S
interface card (slave) (Large cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2X-D-FB2-TP
Translucent door option for large cabinet*
2X-D-FB2-TP-S
Translucent door option for small cabinet*
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls
Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small
cabinet
1199a/R02
Incorporating the following units:
2010-2FR-MB
KFP-A-UI-FB2
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
ZP2-FR-FB2 ZP2-FR-FB2S
KFP-A-ZI-20
(20 Zone) (Large cabinet variant only)
KFP-A-ZI-40
(40 Zone) (Large cabinet variant only)
KFP-A-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
KFP-A-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB
only)
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
ADP-N3E-U IFAM
interface card (master) (Large cabinet variant only)
ADP-N3S
interface card (slave) (Large cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls
Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small
cabinet
1199a/R02
Incorporating the following units:
2010-2FR-MB
ZP2-UI-FB2
20 Oct 2014
Main control board
User interface control board
155
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2010-2-PS-40 4A
Power Supply
And as optional modules:
2X-FR-SC
ZP2-ZI-20
(20 Zone) (Large cabinet variant only)
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
ZP2-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board (Germany) (Large cabinet variant
2010-2-PIB
only)
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I
only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
ADP-N3E-U IFAM
interface card (master) (Large cabinet variant only)
ADP-N3S
interface card (slave) (Large cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
ZP2-D-FB2-TP
Translucent door option for large cabinet*
ZP2-D-FB2-TP-S
Translucent door option for small cabinet*
Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls
(Scandinavia)
Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small
cabinet (Scandinavia)
1199a/R03
Incorporating the following units:
2010-2FR-MB
Main control board
2X-UI-SC
User interface control board
2010-2-PS-40 4A
Power Supply
And as optional modules:
KFP-A-FR-SC, KFP-A-FRSC-S
2X-ZI-20
(20 Zone) (Large cabinet variant only)
2X-ZI-40
(40 Zone) (Large cabinet variant only)
2X-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
2X-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PIB
Peripheral Interface Board (Germany)
2010-2-PIB-8O
Peripheral Interface Board 8 outputs (Large cabinet variant only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet
variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls
(Scandinavia)
Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small
cabinet (Scandinavia)
1199a/R03
Incorporating the following units:
2010-2FR-MB
KFP-A-UI-SC
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
KFP-A-ZI-20
KFP-A-ZI-40
2010-2-NB
KFP-A-LB
2010-2-232-KIT
156
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
Network card
Loop Board (Large cabinet variant only)
Interface board for external printer
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
ZP2-FR-SC, ZP2-FR-SC-S
LPCB Ref.
No.
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls
(Scandinavia)
Intelligent Analogue Addressable Fire Panel Repeater with fire brigade controls small
cabinet (Scandinavia)
1199a/R03
Incorporating the following units:
2010-2FR-MB
ZP2-UI-SC
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
2X-ER, 2X-ER-S
ZP2-ZI-20
(20 Zone) (Large cabinet variant only)
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
2010-2-NB
Network card
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Inte rface board for external printer
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade
controls
Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade
controls small cabinet
1199a/R04
Incorporating the following units:
2010-2FR-MB
2X-UI-E
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
2X-ZI-20
2X-ZI-40
2X-ZI-24-S
2010-2-NB
2X-LB
2010-2-232-KIT
2010-2-PS-C2
2010-2-PS-C2-S
2010-2-PIB-8O
2010-2-PIB-8I
2010-2-PIB-8I8O
variant only)
2010-2-DACT
2X-D-E-TP
2X-D-E-TP-S
2010-FS-EOL
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
(24 Zone) (Small cabinet variant only)
Network card
Loop Board (Large cabinet variant only)
Interface board for external printer
UK mains cable for large cabinet
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant only)
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet
with ATS7310 (GSM module)
Translucent door option for large cabinet*
Translucent door option for small cabinet*
Fault Supervision End of Line unit
The above ancillary repeater units are certified with the following options with
requirements from EN 54-2:
7.13
20 Oct 2014
Alarm counter
157
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
8.4
8.9
9.5
S variants only)
10
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points (available on 2X-ER and 2X-ERTest condition (available on 2X-ER and 2X-ER-S variants only)
*Important: the translucent door does not meet EN54-2 access level 1 requirements. To
meet EN54-2 requirements with
the door fitted the following is also required:
1) A Zone indicator board to display the zones in alarm (to meet requirements of EN54-2
part 7.3)
KFP-A-ER KFP-A-ER-S
2) An MCP fitted beside the panel to allow overriding of delays (to meet requirements of
EN54-2 part 7.11)
Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade
controls
Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade
controls small cabinet
1199a/R04
Incorporating the following units:
2010-2FR-MB
KFP-A-UI-E
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
KFP-A-ZI-20
(20 Zone) (Large cabinet variant only)
KFP-A-ZI-40
(40 Zone) (Large cabinet variant only)
KFP-A-ZI-24-S
(24 Zone) (Small cabinet variant only)
2010-2-NB
Network card
KFP-A-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
Peripheral Interface Board 8 inputs (Large cabinet variant
2010-2-PIB-8I
only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Above ancillary repeater units are certified with the following options with requirements
from EN 54-2:
ZP2-ER, ZP2-ER-S
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points (available on 2X-ER and
2X-ER-S variants only)
10
Test condition (available on 2X-ER and 2X-ER-S variants only
Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade
controls
Intelligent Analogue Addressable Fire and Evacuation Panel Repeater with fire brigade
controls small cabinet
1199a/R04
Incorporating the following units:
2010-2FR-MB
ZP2-UI-E
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
ZP2-ZI-20
ZP2-ZI-40
ZP2-ZI-24-S
2010-2-NB
ZP2-LB
158
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
(24 Zone) (Small cabinet variant only)
Network card
Loop Board (Large cabinet variant only)
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2010-2-232-KIT
2010-2-PS-C2
2010-2-PS-C2-S
2010-2-PIB-8O
only)
2010-2-PIB-8I
2010-2-PIB-8I8O
cabinet variant only)
2010-2-DACT
2010-FS-EOL
ZP2-D-E-TP
ZP2-D-E-TP-S
Interface board for external printer
UK mains cable for large cabinet
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
with ATS7310 (GSM module)
Fault Supervision End of Line unit
Translucent door option for large cabinet*
Translucent door option for small cabinet
Certified with the following options with requirements from EN 54-2:
2X-FR-SCFB, 2X-FRSCFB-S
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points (available on 2X-ER and 2XER-S variants only)
10
Test condition (available on 2X-ER and 2X-ER-S variants only)
Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls
(Scandinavia)
Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls
small cabinet (Scandinavia)
1199a/R05
Incorporating the following units:
2010-2FR-MB
2X-UI-SCFB
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
KFP-A-FR-SCFB, KFP-AFR-SCFB-S
2X-ZI-20
(20 Zone) (Large cabinet variant only)
2X-ZI-40
(40 Zone) (Large cabinet variant only)
2010-2-NB
Network card
2X-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
2010-2-PIB-8O
Peripheral Interface Board 8 outputs (Large cabinet variant only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large cabinet
variant only)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls
(Scandinavia)
Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls
small cabinet (Scandinavia)
1199a/R05
Incorporating the following units:
2010-2FR-MB
KFP-A-UI-SCFB
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
KFP-A-ZI-20
KFP-A-ZI-40
2010-2-NB
KFP-A-LB
2010-2-232-KIT
2010-SK
2010-2-PS-C2
2010-2-PS-C2-S
2010-2-PIB-8O
only)
2010-2-PIB-8I
2010-2-PIB-8I8O
20 Oct 2014
(20 Zone) (Large cabinet variant only)
(40 Zone) (Large cabinet variant only)
Network card
Loop Board (Large cabinet variant only)
Interface board for external printer
Scandinavian key and lock assembly
UK mains cable for large cabinet
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
Peripheral Interface Board 8 inputs (Large cabinet variant only)
Peripheral Interface Board 8 outputs and 8 inputs (Large
159
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
ZP2-FR-SCFB, ZP2-FRSCFB-S
LPCB Ref.
No.
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls
(Scandinavia)
Intelligent Analogue Addressable Fire Panel Repeater with SS3654 fire brigade controls
small cabinet (Scandinavia)
1199a/R05
Incorporating the following units:
2010-2FR-MB
ZP2-UI-SCFB
2010-2-PS-40 4A
Main control board
User interface control board
Power Supply
And as optional modules:
1X-F2 1X-F2 1X-F2-SC
160
ZP2-ZI-20
(20 Zone) (Large cabinet variant only)
ZP2-ZI-40
(40 Zone) (Large cabinet variant only)
2010-2-NB
Network card
ZP2-LB
Loop Board (Large cabinet variant only)
2010-2-232-KIT
Interface board for external printer
2010-SK
Scandinavian key and lock assembly
2010-2-PS-C2
UK mains cable for large cabinet
2010-2-PS-C2-S
UK mains cable for small cabinet
Peripheral Interface Board 8 outputs (Large cabinet variant
2010-2-PIB-8O
only)
2010-2-PIB-8I
Peripheral Interface Board 8 inputs (Large cabinet variant only)
2010-2-PIB-8I8O
Peripheral Interface Board 8 outputs and 8 inputs (Large
cabinet variant only)
2010-2-DACT
with ATS7310 (GSM module)
2010-FS-EOL
Fault Supervision End of Line unit
Conventional two zone control and indicating equipment
Conventional two zone control and indicating equipment with Scandinavian key switch
I
ncorporating the following units:
2010-2F1- MB Main control board
2X-UI User interface control board
2010-2-PS-40 4A Power Supply
And as optional modules:
2X-ZI-20 (20 Zone) (Large cabinet variant only)
2X-ZI-40 (40 Zone) (Large cabinet variant only)
2010-2-NB Network card
2X-LB Loop Board (Large cabinet variant only)
2010-2-232-KIT Interface board for external printer
2010-2-PS-C2 UK mains cable for large cabinet
2010-2-PS-C2-S UK mains cable for small cabinet
2010-2-PIB-8O Peripheral Interface Board 8 outputs (Large cabinet
variant only)
2010-2-PIB-8I Peripheral Interface Board 8 inputs (Large cabinet variant
only)
2010-2-PIB-8I8O Peripheral Interface Board 8 outputs and 8 inputs (Large
cabinet variant only)
2010-2-DACT with ATS7310 (GSM module)
2X-D-TP Translucent door option for large cabinet*
2X-D-TP-S Translucent door option for small cabinet*
2010-FS-EOL Fault Supervision End of Line unit
1) This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
International English
3) Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04
German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK)
Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU)
German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States
of America-18
Polish Poland-19 Turkish Turkey-20 Spanish Spain-10 Italian Italy-11 Dutch (BE)
Belgium-12 Irish Ireland-
1199b/01
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
KFP-CF2 KFP-CF2-SC
SG-2000 SG-2000SC
1X-F4
SC
1X-F4-NL 1X-F4-
20 Oct 2014
LPCB Ref.
No.
13 German (AU) German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English
(US) United States
of America-18 Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21
Portuguese Portugal-22
Hungarian Hungary
-23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian
Lithuania-28
Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32
French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40
Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45
Romanian (RO)
Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian
Macedonia-50
Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99
English (Int
Conventional two zone control and indicating equipment
Conventional two zone control and indicating equipment with Scandinavian key switch
Conventional two zone control and indicating equipment
Conventional two zone control and indicating equipment with Scandinavian key switch
Conventional two zone control and indicating equipment
Conventional two zone control and indicating equipment with Scandinavian key
switch
Incorporating the following units:
1X-F2-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-20 2A Power Supply
2010-SK Scandinavian Key Lock and Key (Applicable to SC
variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.11 Delays to outputs
8.4 Total loss of the power supply
10 Test condition
1) This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04
German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK)
Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU)
German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States
of America-18
Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian
Hungary
-23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27 Lithuanian
Lithuania-28
Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia-32
French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40
Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45
Romanian (RO)
Romania
-46 German (Int) International German-48 Croatian Croatia-49 Macedonian Macedonia50 Slovenian
1X-F4
1X-F4-NL
1X-F4-SC
Incorporating the following units:
1X-F4-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
1199b/01
1199b/01
1199b/02
161
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2010-1-NB Optional Network board
2010-PS-20 2A Power Supply
2010-1-AC Alarm Counter (Applicable to NL variant)
2010-SK Scandinavian Key Lock and Key (Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
10 Test condition
Also certified with the following options with requirements from EN 54-2 when
configured in the NEN operating mode:
KFP-CF4 KFP-CF4-NL
KFP-CF4-SC
162
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing
equipment
7.10.1 Output to fire protection equipment -Type A
7.11 Delays to outputs - Applicable to fire alarm routing
equipment only
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
8.9 Output to fault warning routing equipment
10 Test condition
1) This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04
German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK)
Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU)
German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States
of America-18
Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian
Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27
Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40
Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45
Romanian (RO)
Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian
Macedonia-50
Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99
English (Int)
International English
KFP-CF4 KFP-CF4-NL KFP-CF4-SC Conventional four zone control and indicating
equipment
Incorporating the following units:
KFP-CF4-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-20 2A Power Supply
2010-1-AC Alarm Counter (Applicable to NL variant)
2010-SK Scandinavian Key Lock and Key (Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
10 Test condition
1199b/02
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
SG-4000 SG-4000SC
20 Oct 2014
LPCB Ref.
No.
Also certified with the following options with requirements from EN 54-2 when
configured in the NEN operating mode:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10.1 Output to fire protection equipment -Type A
7.11 Delays to outputs - Applicable to fire alarm routing equipment
only
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
8.9 Output to fault warning routing equipment
10 Test condition
1) This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04
German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK)
Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU)
German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States
of America-18
Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian
Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27
Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40
Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45
Romanian (RO)
Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian
Macedonia-50
Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99
English (Int)
International English
SG-4000 SG-4000SC Conventional eight zone control and indicating equipment
Conventional eight zone control and indicating equipment
Conventional eight zone control and indicating equipment
Incorporating the following units:
1X-F4-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-20 2A Power Supply
2010-SK Scandinavian Key Lock and Key (Applicable to SC variant
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
8.4 Total loss of the power supply
10 Test condition
1) This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04
German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK)
Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU)
German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States
of America-18
Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian
1199b/02
163
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
ZP1-F4 ZP1-F4-NL ZP1F4-SC
LPCB Ref.
No.
Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27
Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40
Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45
Romanian (RO)
Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian
Macedonia-50
Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99
English (Int)
International English
ZP1-F4 ZP1-F4-NL ZP1-F4-SC Conventional four zone control and indicating equipment
1199b/02
Incorporating the following units:
1X-F4-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-20 2A Power Supply
2010-1-AC Alarm Counter (Applicable to NL variant)
2010-SK Scandinavian Key Lock and Key (Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
10 Test condition
Also certified with the following options with requirements from EN 54-2 when
configured in the NEN operating mode:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10.1 Output to fire protection equipment -Type A
7.11 Delays to outputs - Applicable to fire alarm routing equipment
only
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
8.9 Output to fault warning routing equipment
10 Test condition
1) This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04
German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK)
Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU)
German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States
of America-18
Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian
Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27
Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40
Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45
Romanian (RO)
Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian
Macedonia-50
Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99
English (Int)
International English
164
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
ZP1-F4 ZP1-F4-NL ZP1F4-SC
1X-F8 1X-F8-NL 1X-F8-SC
ZP1-F4 ZP1-F4-NL ZP1-F4-SC Conventional four zone control and indicating equipment
Incorporating the following units:
1X-F4-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-20 2A Power Supply
2010-1-AC Alarm Counter (Applicable to NL variant)
2010-SK Scandinavian Key Lock and Key (Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
10 Test condition
Also certified with the following options with requirements from EN 54-2 when
configured in the NEN operating mode:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10.1 Output to fire protection equipment -Type A
7.11 Delays to outputs - Applicable to fire alarm routing equipment
only
1X-F8 1X-F8-NL 1X-F8-SC Conventional eight zone control and indicating equipment
Incorporating the following units:
LPCB Ref.
No.
1199b/02
1199b/03
1X-F8-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-40 4A Power Supply
2010-1-AC Alarm Counter ( Applicable to NL variant)
2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
7.13 Alarm counter ( Applicable to NL variant only)
8.4 Total loss of the power supply
10 Test condition
Also certified with the following options with requirements from EN 54-2 when
configured in the NEN operating mode:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10.1 Output to fire protection equipment -Type A
7.11 Delays to outputs - Applicable to fire alarm routing equipment
1X-F8-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-40 4A Power Supply
2010-1-AC Alarm Counter ( Applicable to NL variant)
2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
7.13 Alarm counter ( Applicable to NL variant only)
8.4 Total loss of the power supply
10 Test condition
Also certified with the following options with requirements from EN 54-2 when
configured in the NEN operating mode:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10.1 Output to fire protection equipment -Type A
20 Oct 2014
165
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
KFP-CF8 KFP-CF8-NL
KFP-CF8-SC
SG-8000 SG-8000SC
166
LPCB Ref.
No.
7.11 Delays to outputs - Applicable to fire alarm routing equipment
KFP-CF8 KFP-CF8-NL KFP-CF8-SC Conventional eight zone control and indicating
equipment
Incorporating the following units:
KFP-CF8-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-40 4A Power Supply
2010-1-AC Alarm Counter ( Applicable to NL variant)
2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
7.13 Alarm counter ( Applicable to NL variant only)
8.4 Total loss of the power supply
10 Test condition
Also certified with the following options with requirements from EN 54-2 when
configured in the NEN operating mode:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10.1 Output to fire protection equipment -Type A
7.11 Delays to outputs - Applicable to fire alarm routing equipment
only
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
8.9 Output to fault warning routing equipment
10 Test condition
1) This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04
German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK)
Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU)
German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States
of America-18
Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian
Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27
Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40
Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45
Romanian (RO)
Romania -46 German (Int) International German-48 Croatian Croatia-49 Macedonian
Macedonia-50
Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99
English (Int)
International English
SG-8000 SG-8000SC Conventional eight zone control and indicating equipment
Conventional eight zone control and indicating equipment
Conventional eight zone control and indicating equipment
Incorporating the following units:
1X-F8-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-40 4A Power Supply
2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
1199b/03
1199b/03
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
8.4 Total loss of the power supply
10 Test condition
1) This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04
German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK)
Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU)
ZP1-F8 ZP1-F8-NL ZP1F8-SC
German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United
States of America-18
Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian
Hungary-23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27
Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40
Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45
Romanian (RO)
Romania-46 German (Int) International German-48 Croatian Croatia-49 Macedonian
Macedonia-50
Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99
English (Int)
International English
ZP1-F8 ZP1-F8-NL ZP1-F8-SC Conventional four zone control and indicating equipment
1199b/03
Incorporating the following units:
1X-F8-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-40 4A Power Supply
2010-1-AC Alarm Counter ( Applicable to NL variant)
2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant)
Incorporating the following units:
1X-F8-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-40 4A Power Supply
2010-1-AC Alarm Counter ( Applicable to NL variant)
2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.10.1 Output to fire protection equipment -Type A
7.11 Delays to outputs - Applicable to fire alarm routing
equipment only
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
8.9 Output to fault warning routing equipment
10 Test condition
Also certified with the following options with requirements from EN 54-2 when
configured in the NEN operating mode:
1) This product approval does not constitute compliance with the fire detection and
alarm systems requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04
20 Oct 2014
167
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
1X-E4 1X-E4-NL
KFP-CE4 KFP-CE4-N
168
LPCB Ref.
No.
German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK)
Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU)
German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States
of America-18
Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian
Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27
Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40
Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45
Romanian (RO)
Romania -46 German (Int) International German-48 Croatian Croatia-49 Macedonian
Macedonia-50
Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99
English (Int)
1X-E4 1X-E4-NL Conventional four zone control and indicating equipment
Incorporating the following units:
1X-E4-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-40 4A Power Supply
2010-1-AC Alarm Counter (Applicable to NL variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
10 Test condition
Also certified with the following options with requirements from EN 54-2 when
configured in the NEN operating mode:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs - Applicable to fire alarm routing equipment
only
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
8.9 Output to fault warning routing equipment
10 Test condition
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04
German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK)
Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU)
German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States
of America-18
Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian
Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27
Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40
Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45
Romanian (RO)
Romania -46 German (Int) International German-48 Croatian Croatia-49 Macedonian
Macedonia-50
Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99
English (Int)
International English
KFP-CE4 KFP-CE4-NL Conventional four zone control and indicating equipment
Incorporating the following units:
1199b/04
1199b/04
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
ZP1-E4 ZP1-E4-NL
20 Oct 2014
LPCB Ref.
No.
KFP-CE4-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-PS-40 4A Power Supply
2010-1-AC Alarm Counter (Applicable to NL variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
10 Test condition
Also certified with the following options with requirements from EN 54-2 when
configured in the NEN operating mode:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs - Applicable to fire alarm routing
equipment only
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
8.9 Output to fault warning routing equipment
10 Test condition
1) This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04
German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK)
Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU)
German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United States
of America-18
Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian
Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27
Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40
Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45
Romanian (RO)
Romania -46 German (Int) International German-48 Croatian Croatia-49 Macedonian
Macedonia-50
Slovenian Slovenia-51 Hebrew
ZP1-E4 ZP1-E4-NL Conventional four zone control and indicating equipment
Incorporating the following units:
1X-E4-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-40 4A Power Supply
2010-1-AC Alarm Counter (Applicable to NL variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
10 Test condition
Also certified with the following options with requirements from EN 54-2 when
configured in the NEN operating mode:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs - Applicable to fire alarm routing equipment
1199b/04
169
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
only
7.13 Alarm counter (Applicable to NL variant only)
8.4 Total loss of the power supply
8.9 Output to fault warning routing equipment
10 Test condition
1) This product approval does not constitute compliance with the fire detection and alarm
systems
requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
-01 Dutch (NL) The Netherlands-02 French (FR) France -03 English (UK) United
Kingdom and Ireland -04
German (DE) Germany-05 Norwegian Norway-06 Swedish Sweden-07 Danish (DK)
Denmark-08 English
(AU) Australia-09 Spanish Spain-10 Italian Italy-11 Dutch (BE) Belgium-12 Irish Ireland13 German (AU)
German (Austria)-14 Greek Greece-15 Arabic Middle East-17 English (US) United
States of America-18
Polish Poland-19 Turkish Turkey-20 Czech Czech Republic-21 Portuguese Portugal-22
Hungarian
Hungary -23 Danish (IC) Iceland-24 Slovakian Slovak Republic-25 Russian Russia-27
Lithuanian Lithuania28 Finnish Finland-29 German (SW) Switzerland-30 Estonian Estonia-31 Latvian Latvia32 French (BE)
Belgium-33 French (SW) Switzerland-34 Italian (SW) Switzerland-36 French (Int)
International French-40
Bulgarian Bulgaria-41 Belarusian Belarus-43 Ukrainian Ukraine-44 Serbian Serbia-45
Romanian (RO)
Romania -46 German (Int) International German-48 Croatian Croatia-49 Macedonian
Macedonia-50
Slovenian Slovenia-51 Hebrew Israel-71 Catalan Catalunia (Spain)-80 Chinese China-99
English (Int)
International English
ZP3 1, 2 and 4 loop analogue addressable control and indicating equipment
1, 2 and 4 loop analogue addressable control and indicating equipment
Incorporating as modular units:
ZP3-MB2-4L 4 Loop Main board
ZP3-MB2-2L 2 Loop Main board
ZP3-MB2-1L 1 Loop Main board
ZP3-CPU1 CPU board
ZP3-DB1 Display board
ZP3-ZB50 50 Zone LED board
ZP3-CB1 Commissioning key switch board
ZP3-PR1 Printer Kit
ZP3AB-SCB-D Control bus driver
ZP3AB-RL8 Programmable relay output board, 8 way
ZP3-AB-MA8 Programmable monitored output board, 8 way
ZP3AB-OP24 Programmable transistor output board, 24 way
ZP3AB-MIP8 Programmable input board, 8 way
ZP3-Xl 230Vac Power supply unit
Approved with the following options from BS EN54 Part 2:
7.8 Output to fire alarm devices
7.9 Output to fire alarm routing equipment
7.10 Output to fire protection equipment
7.11 Delays to outputs
7.12 Co-incidence detection
7.13 Alarm counter
8.3 Fault signals from points
8.4 Total loss of power
8.9 Output to fault routing equipment
9.5 Disablement of addressable points
10 Test condition
11 Standardised input/output interface
170
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
UTC Fire & Security (Africa) trading as Ziton
Ziton House, 555 Voortrekker Road, Maitland 7405, Cape Town, South Africa
Tel: +27 21 5066000 • Fax: +27 21 5066100
Website: www.utcfireandsecurity.com
UK Sales Enquiries:
Tel: +44 (0)1908 281981 • Fax: +44 (0)1908 282554
Certificate No: 092h to BS EN 54-2: 1998 and BS EN 54-4: 1998
N.B. This certificate is to a withdrawn standard. Control and indicating equipment conforming to this standard is not suitable for
use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because
control and indicating equipment meeting the withdrawn standard is still requested by some regulators outside of the EU.
Certificated Products
ZP3
1, 2 and 4 loop analogue addressable control and indicating equipment
Incorporating as modular units:
LPCB Ref.
No.
092h/01
ZP3-MB2-4L
4 Loop Main board
ZP3-MB2-2L
2 Loop Main board
ZP3-MB2-1L
1 Loop Main board
ZP3-CPU1
CPU board
ZP3-DB1
Display board
ZP3-ZB50
50 Zone LED board
ZP3-CB1
Commissioning key switch board
ZP3-PR1
Printer Kit
ZP3AB-SCB-D
Control bus drive
ZP3AB-RL8
Programmable relay output board, 8 way
ZP3-AB-MA8
Programmable monitored output board, 8 way
ZP3AB-OP24
Programmable transistor output board, 24 way
ZP3AB-MIP8
Programmable input board, 8 way
ZP3-xL
230V ac Power supply unit
Approved with the following options from EN54-2:
7.8
Output to fire alarm devices
7.9
Output to fire alarm routing equipment
7.10
Output to fire protection equipment
7.11
Delays to outputs
7.12
Co-incidence detection
7.13
Alarm counter
8.3
Fault signals from points
8.9
Output to fault routing equipment
9.5
Disablement of addressable points
10.0
Test condition
11.0
Standardised input/output interface
UTC Fire & Security (Pty) LTD Trading as Ziton
Ziton House, 555 Voortrekker Road, Maitland 7405, South Africa
Tel: +27 21 5066000 • Fax: +27 21 5066100
Website: www.ziton.com
Certificate No: 092h to BS EN 54 - 2: 1998 and BS EN 54- 4: 1998 N.B. This certificate is to a withdrawn standard. Control and
indicating equipment conforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). This
certificate, to the withdrawn standard, is maintained because controland indicating equipment meeting the withdrawn standard
is still requested by some regulators outside of the EU.
Certificated Products
ZP3 (Traditional Chinese
Language Variant)
1, 2 and 4 loop analogue addressable control and indicating equipment
LPCB Ref.
No.
092h/01
Incorporating as modular units:
20 Oct 2014
171
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
ZP3-MB2-4L
4 Loop Main board
ZP3-MB2-2L
2 Loop Main board
ZP3-MB2-1L
1 Loop Main board
ZP3-CPU1
CPU board
ZP3-DB1
Display board
ZP3-ZB50
50 Zone LED board
ZP3-CB1
Commissioning key switch board
ZP3-PR1
Printer Kit
ZP3AB-SCB-D Control bus driver
ZP3AB-RL8
Programmable relay output board, 8 way
ZP3-AB-MA8
Programmable monitored output board, 8 way
ZP3AB-OP24
Programmable transistor output board, 24 way
ZP3AB-MIP8
Programmable input board, 8 way
ZP3-Xl 230Vac Power supply unit
Approved with the following options from BS EN54 Part 2:
7.8
7.9
7.10
7.11
7.12
7.13
8.3
8.4
8.9
9.5
10
11
Output to fire alarm devices
Output to fire alarm routing equipment
Output to fire protection equipment
Delays to outputs
Co-incidence detection
Alarm counter
Fault signals from points
Total loss of power
Output to fault routing equipment
Disablement of addressable points
Test condition
Standardised input/output interface
UTC Fire & Security BV
Kelvinstraat 7, NL-6003DH, Weert, The Netherlands
Tel: + 31 495 58 30 00 • Fax: + 31 495 55 00 42
E-mail: Daragh.O'[email protected] • Website: www.utcfireandsecurity.com
Certificate No: 1199c to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006
Certificate No: 1199c to EN 54-2: 1997 + A1:2006 EN54-4:1997 + A1:2002+ A2:2002
Certificated Products
SG2000
LPCB Ref.
No.
092v/01
Conventional two zone control and indicating equipment
Incorporating the following units:
1X-F2-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-20 2A Power Supply
2010-SK Scandinavian Key Lock and Key (Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.11 Delays to outputs
8.4 Total loss of the power supply
10 Test condition
1) This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07
Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20
Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28
Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45
Romanian, 71 Catalan, 99 - English (International)
172
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
SG2000SC
LPCB Ref.
No.
Conventional two zone control and indicating equipment with Scandinavian key switch
092v/01
Incorporating the following units:
1X-F2-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-20 2A Power Supply
2010-SK Scandinavian Key Lock and Key (Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.11 Delays to outputs
8.4 Total loss of the power supply
10 Test condition
SG4000
1) This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
01 - Dutch, 02 -French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 - Swedish,
07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 - Arabic, 18 - Polish, 19 Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27Lithuanian, 28 - Finish, 30 - Estonian, 31 - Latvian, 32 - Belgian French, 36 - French
International, 45 - Romanian, 71 - Catalan, 99 - English (International)
Conventional four zone control and indicating equipment
092v/02
Incorporating the following units:
1X-F4-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-20 2A Power Supply
2010-SK Scandinavian Key Lock and Key (Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
8.4 Total loss of the power supply
10 Test condition
SG4000SC
1) This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07
Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20
Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28
Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45
Romanian, 71 Catalan, 99 - English (International)
Conventional four zone control and indicating equipment with Scandinavian key switch
092v/02
Incorporating the following units:
1X-F4-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-20 2A Power Supply
2010-SK Scandinavian Key Lock and Key (Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
20 Oct 2014
173
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
8.4 Total loss of the power supply
10 Test condition
SG8000
1) This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07
Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20
Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28
Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45
Romanian, 71 Catalan, 99 - English (International)
Conventional eight zone control and indicating equipment
092v/03
Incorporating the following units:
1X-F8-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-40 4A Power Supply
2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
8.4 Total loss of the power supply
10 Test condition
SG8000SC
1) This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07
Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20
Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28
Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45
Romanian, 71 Catalan, 99 - English (International)
Conventional eight zone control and indicating equipment with Scandinavian key switch
092v/03
Incorporating the following units:
1X-F8-MB Main control board
2010-1-RB Optional relay board
2010-1-SB Optional expander I/O board
2010-1-NB Optional Network board
2010-PS-40 4A Power Supply
2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant)
Certified with the following options with requirements from EN 54-2:
7.8 Output to fire alarm device(s)
7.9.1 Output to fire alarm routing equipment
7.9.2 Alarm confirmation input from fire alarm routing equipment
7.11 Delays to outputs
8.4 Total loss of the power supply
10 Test condition
2X-F1
174
1) This product approval does not constitute compliance with the fire detection and alarm
systems requirements of EN 54-13.
2) Scope of approval does not include the operation of the network functionality.
3) Available with the following language kits:
01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07
Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20
Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28
Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45
Romanian, 71 Catalan, 99 - English (International)
1 Loop intelligent analogue addressable control and indicating equipment
092v/05
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating the following units:
2010-2-F1-MB
Main control board
2X-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
Network board
2-Loop Node Card
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
2X-F1-FB
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
3. Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
1 Loop intelligent analogue addressable control and indicating equipment with fire alarm
routing output
092v/05
Incorporating the following units:
2010-2-F1-MB
Main control board
2X-UI-FB
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-232-IB
2010-2-LB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
Network board
Interface Board for External Printer
Loop expansion board
20 zone LED indication board
40 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Type A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
20 Oct 2014
This product approval does not constitute compliance with the fire detection
175
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
2X-F1-SC
092v/05
1 Loop intelligent analogue addressable control and indicating equipment with
Scandinavian key switch
Incorporating the following units:
2010-2-F1-MB
Main control board
2X-UI-SC
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
2010-SK
Network board
Loop expansion board
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Scandinavian key and lock assembly
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Type A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
2X-F2
2 Loop intelligent analogue addressable control and indicating equipment
092v/06
Incorporating the following units:
2010-2-F2-MB
Main control board
2X-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
Network board
Loop expansion board
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
176
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
2.
3.
2X-F2-FB
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Scope of approval does not include the operation of the network functionality.
Available in the following language variants:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
2 Loop intelligent analogue addressable control and indicating equipment
092v/06
Incorporating the following units:
2010-2-F2-MB
Main control board
2X-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
Network board
Loop expansion board
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
2.
3.
2X-F2-SC
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Scope of approval does not include the operation of the network functionality.
Available in the following language variants:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
2 Loop intelligent analogue addressable control and indicating equipment with
Scandinavian key switch
092v/06
Incorporating the following units:
2010-2-F2-MB
Main control board
2X-UI-SC
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
20 Oct 2014
Network board
Loop expansion board
177
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
2010-SK
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Scandinavian key and lock assembly
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
2X-F1-S
092v/07
1 Loop intelligent analogue addressable fire control panel in small cabinet
Incorporating the following units:
2010-2-F1-MB
Main control board
2X-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
2.
3.
2X-F1-FB-S
178
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
1 Loop intelligent analogue addressable fire control panel with fire alarm routing
092v/08
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
equipment output in small cabinet
Incorporating the following units:
2010-2-F1-MB
Main control board
2X-UI-FB
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
2.
3.
2X-F1-SC-S
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
1 Loop intelligent analogue addressable fire control panel with fire alarm routing
equipment output and Scandinavian key in small cabinet
092v/09
Incorporating the following units:
2010-2-F1-MB
Main control board
2X-UI-SC
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
2010-SK
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Scandinavian key and lock assembly
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
20 Oct 2014
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
179
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
10
Test condition
Notes:
1.
2.
3.
2X-F2-S
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
092v/10
2 Loop intelligent analogue addressable fire control panel in small cabinet
Incorporating the following units:
2010-2-F2-MB
Main control board
2X-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
2.
3.
2X-F2-FB-S
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
2 Loop intelligent analogue addressable fire control panel with fire alarm routing
equipment output in small cabinet
092v/11
Incorporating the following units:
2010-2-F2-MB
Main control board
2X-UI-FB
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
180
Output to fire alarm device(s)
Output to fire alarm routing equipment
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
3. Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
2X-F2-SC-S
2 Loop intelligent analogue addressable fire control panel with fire alarm routing
equipment output and Scandinavian key
092v/12
Incorporating the following units:
2010-2-F2-MB
Main control board
2X-UI-SC
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
2010-SK
Scandinavian key and lock assembly
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
2X-FR
Addressable Fire Panel Repeater
092v/R01
Incorporating the following options with requirements from EN 54-2:
7.13
20 Oct 2014
Alarm counter
181
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
2X-FR-FB
LPCB Ref.
No.
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater with Output to Fire Routing Equipment
092v/R02
Incorporating the following options with requirements from EN 54-2:
2X-FR-SC
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater with Scandinavian Key
092v/R03
Incorporating the following options with requirements from EN 54-2:
2X-FR-S
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater in small cabinet
092v/R04
Incorporating the following options with requirements from EN 54-2:
2X-FR-SC-S
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian
key in small cabinet
092v/R05
Incorporating the following options with requirements from EN 54-2:
2X-FR-FB-S
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater with fire alarm routing equipment output in small
cabinet
092v/R06
Incorporating the following options with requirements from EN 54-2:
7.13
8.4
8.9
9.5
10
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
ZPU (Traditional Chinese Language Variant) 1, 2 and 4 loop analogue
equipment
Incorporating as modular units:
ZP3-MB2-4L
ZP3-MB2-2L
ZP3-MB2-1L
ZP3-CPU1
ZP3-DB1
ZP3-ZB50
ZP3-CB1
ZP3-PR1
ZP3AB-SCB-D
ZP3AB-RL8
ZP3-AB-MA8
ZP3AB-OP24
ZP3AB-MIP8
ZP3-Xl
182
addressable control and indicating
4 Loop Main board
2 Loop Main board
1 Loop Main board
CPU board
Display board
50 Zone LED board
Commissioning key switch board
Printer Kit
Control bus driver
Programmable relay output board, 8 way
Programmable monitored output board, 8 way
Programmable transistor output board, 24 way
Programmable input board, 8 way
230Vac Power supply unit
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Approved with the following options from BS EN54 Part 2:
7.8
7.9
7.10
7.11
7.12
7.13
8.3
8.4
8.9
9.5
10
11
Output to fire alarm devices
Output to fire alarm routing equipment
Output to fire protection equipment
Delays to outputs
Co-incidence detection
Alarm counter
Fault signals from points
Total loss of power
Output to fault routing equipment
Disablement of addressable points
Test condition
Standardised input/output interface
Certificate No: 1199c(cl-1) to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006
Certificated Products
KFP-AF1
1 Loop intelligent analogue addressable control and indicating equipment
LPCB Ref.
No.
092v/05
Incorporating the following units:
2010-2-F1-MB
Main control board
KFP-A-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
Network board
2-Loop Node Card
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
2.
3.
KFP-AF1-FB
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
1 Loop intelligent analogue addressable control and indicating equipment with fire alarm
routing output
092v/05
Incorporating the following units:
2010-2-F1-MB
Main control board
KFP-A-UI-FB
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-232-IB
20 Oct 2014
Network board
Interface Board for External Printer
183
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2010-2-LB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
Loop expansion board
20 zone LED indication board
40 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Type A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
KFP-AF1-SC
1 Loop intelligent analogue addressable control and indicating equipment with
Scandinavian key switch
092v/05
Incorporating the following units:
2010-2-F1-MB
Main control board
KFP-A-UI-SC
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
2010-SK
Network board
Loop expansion board
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Scandinavian key and lock assembly
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Type A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
184
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
KFP-AF2
2 Loop intelligent analogue addressable control and indicating equipment
092v/06
Incorporating the following units:
2010-2-F2-MB
Main control board
KFP-A-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
Network board
Loop expansion board
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
2.
3.
KFP-AF2-FB
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Scope of approval does not include the operation of the network functionality.
Available in the following language variants:
01 – Dutch, 02 – French, 03 – English (UK), 04 – German, 05 – Norwegian, 06
– Swedish, 07 – Danish, 09 – Spanish, 10 – Italian,11 – Belgian, Dutch, 15 –
Arabic, 18 – Polish, 19 – Turkish, 20 – Czech, 21 – Portuguese, 22 –
Hungarian, 24 – Slovakian, 25 – Russian, 27- Lithuanian, 28 – Finish, 30 –
Estonian, 31 – Latvian, 32 - Belgian French, 36 – French International, 45 –
Romanian, 71 – Catalan, 99 - English (International)
2 Loop intelligent analogue addressable control and indicating equipment with fire alarm
routing output
092v/06
Incorporating the following units:
2010-2-F2-MB
Main control board
KFP-A-UI-FB
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
Network board
Loop expansion board
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
20 Oct 2014
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
185
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
9.5
10
Disablement of addressable points
Test condition
Notes:
1.
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 – Dutch, 02 – French, 03 – English (UK), 04 – German, 05 – Norwegian, 06
– Swedish, 07 – Danish, 09 – Spanish, 10 – Italian,11 – Belgian, Dutch, 15 –
Arabic, 18 – Polish, 19 – Turkish, 20 – Czech, 21 – Portuguese, 22 –
Hungarian, 24 – Slovakian, 25 – Russian, 27- Lithuanian, 28 – Finish, 30 –
Estonian, 31 – Latvian, 32 - Belgian French, 36 – French International, 45 –
Romanian, 71 – Catalan, 99 - English (International)
KFP-AF2-SC
092v/06
2 Loop intelligent analogue addressable control and indicating equipment with
Scandinavian key switch
Incorporating the following units:
2010-2-F2-MB
Main control board
KFP-A-UI-SC
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
2010-SK
Network board
Loop expansion board
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Scandinavian key and lock assembly
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
KFP-AF1-S
1 Loop intelligent analogue addressable fire control panel in small cabinet
092v/07
Incorporating the following units:
2010-2-F1-MB
Main control board
KFP-A-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
186
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2010-2-PS-C2
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
2.
3.
KFP-AF1-FB-S
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
1 Loop intelligent analogue addressable fire control panel with fire alarm routing
equipment output in small cabinet
092v/08
Incorporating the following units:
2010-2-F1-MB
Main control board
KFP-A-UI-FB
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
2.
3.
KFP-AF1-SC-S
20 Oct 2014
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
1 Loop intelligent analogue addressable fire control panel with fire alarm routing
equipment output and Scandinavian key in small cabinet
092v/09
187
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating the following units:
2010-2-F1-MB
Main control board
KFP-A-UI-SC
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
2010-SK
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Scandinavian key and lock assembly
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
KFP-AF2-S
2 Loop intelligent analogue addressable fire control panel in small cabinet
092v/10
Incorporating the following units:
2010-2-F2-MB
Main control board
KFP-A-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1.
2.
188
This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
Scope of approval does not include the operation of the network functionality.
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
3.
KFP-AF2-FB-S
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
2 Loop intelligent analogue addressable fire control panel with fire alarm routing
equipment output in small cabinet
092v/11
Incorporating the following units:
2010-2-F2-MB
Main control board
KFP-A-UI-FB
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
3. Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
KFP-AF2-SC-S
2 Loop intelligent analogue addressable fire control panel with fire alarm routing
equipment output and Scandinavian key
092v/12
Incorporating the following units:
2010-2-F2-MB
Main control board
KFP-A-UI-SC
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
2010-SK
Scandinavian key and lock assembly
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
20 Oct 2014
Output to fire alarm device(s)
Output to fire alarm routing equipment
189
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
KFP-AFR
Addressable Fire Panel Repeater
092v/R01
Incorporating the following options with requirements from EN 54-2:
KFP-AFR-FB
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater with Output to Fire Routing Equipment
092v/R02
Incorporating the following options with requirements from EN 54-2:
KFP-AFR-SC
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater with Scandinavian Key
092v/R03
Incorporating the following options with requirements from EN 54-2:
KFP-AFR-S
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater in small cabinet
092v/R04
Incorporating the following options with requirements from EN 54-2:
KFP-AFR-SC-S
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian
key in small cabinet
092v/R05
Incorporating the following options with requirements from EN 54-2:
KFP-AFR-FB-S
190
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater with fire alarm routing equipment output in small
cabinet
092v/R06
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
Incorporating the following options with requirements from EN 54-2:
7.13
8.4
8.9
9.5
10
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
ZP3 1, 2 and 4 loop analogue addressable control and indicating equipment
Incorporating as modular units:
ZP3-MB2-4L
ZP3-MB2-2L
ZP3-MB2-1L
ZP3-CPU1
ZP3-DB1
ZP3-ZB50
ZP3-CB1
ZP3-PR1
ZP3AB-SCB-D
ZP3AB-RL8
ZP3-AB-MA8
ZP3AB-OP24
ZP3AB-MIP8
ZP3-Xl
4 Loop Main board
2 Loop Main board
1 Loop Main board
CPU board
Display board
50 Zone LED board
Commissioning key switch board
Printer Kit
Control bus driver
Programmable relay output board, 8 way
Programmable monitored output board, 8 way
Programmable transistor output board, 24 way
Programmable input board, 8 way
230Vac Power supply unit
Approved with the following options from BS EN54 Part 2:
7.8
7.9
7.10
7.11
7.12
7.13
8.3
8.4
8.9
9.5
10
11
Output to fire alarm devices
Output to fire alarm routing equipment
Output to fire protection equipment
Delays to outputs
Co-incidence detection
Alarm counter
Fault signals from points
Total loss of power
Output to fault routing equipment
Disablement of addressable points
Test condition
Standardised input/output interface
Incorporating as modular units:
ZP3-MB2-4L
ZP3-MB2-2L
ZP3-MB2-1L
ZP3-CPU1
ZP3-DB1
ZP3-ZB50
ZP3-CB1
ZP3-PR1
ZP3AB-SCB-D
ZP3AB-RL8
ZP3-AB-MA8
ZP3AB-OP24
ZP3AB-MIP8
ZP3-Xl
4 Loop Main board
2 Loop Main board
1 Loop Main board
CPU board
Display board
50 Zone LED board
Commissioning key switch board
Printer Kit
Control bus driver
Programmable relay output board, 8 way
Programmable monitored output board, 8 way
Programmable transistor output board, 24 way
Programmable input board, 8 way
230Vac Power supply unit
Approved with the following options from BS EN54 Part 2:
7.8
7.9
7.10
7.11
7.12
7.13
8.3
8.4
8.9
Output to fire alarm devices
Output to fire alarm routing equipment
Output to fire protection equipment
Delays to outputs
Co-incidence detection
Alarm counter
Fault signals from points
Total loss of power
Output to fault routing equipment
20 Oct 2014
191
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
9.5
Disablement of addressable points
10
Test condition
11
Standardised input/output interface
Incorporating as modular units:
ZP3-MB2-4L
ZP3-MB2-2L
ZP3-MB2-1L
ZP3-CPU1
ZP3-DB1
ZP3-ZB50
ZP3-CB1
ZP3-PR1
ZP3AB-SCB-D
ZP3AB-RL8
ZP3-AB-MA8
ZP3AB-OP24
ZP3AB-MIP8
ZP3-Xl
4 Loop Main board
2 Loop Main board
1 Loop Main board
CPU board
Display board
50 Zone LED board
Commissioning key switch board
Printer Kit
Control bus driver
Programmable relay output board, 8 way
Programmable monitored output board, 8 way
Programmable transistor output board, 24 way
Programmable input board, 8 way
230Vac Power supply unit
Approved with the following options from BS EN54 Part 2:
7.8
7.9
7.10
7.11
7.12
7.13
8.3
8.4
8.9
9.5
10
11
Output to fire alarm devices
Output to fire alarm routing equipment
Output to fire protection equipment
Delays to outputs
Co-incidence detection
Alarm counter
Fault signals from points
Total loss of power
Output to fault routing equipment
Disablement of addressable points
Test condition
Standardised input/output interface
Certificate No: 092v-(cl-2) to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006
Ziton - ZP2
Certificated Products
ZP2-F1
1 Loop intelligent analogue addressable control and indicating equipment
LPCB Ref.
No.
092v/05
Incorporating the following units:
2010-2-F1-MB
Main control board
ZP-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
Network board
2-Loop Node Card
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
192
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
3. Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
ZP2-F1-FB
1 Loop intelligent analogue addressable control and indicating equipment with fire alarm
routing output
092v/05
Incorporating the following units:
2010-2-F1-MB
Main control board
ZP2-UI-FB
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-232-IB
2010-2-LB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
Network board
Interface Board for External Printer
Loop expansion board
20 zone LED indication board
40 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Type A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
ZP2-F1-SC
1 Loop intelligent analogue addressable control and indicating equipment with
Scandinavian key switch
092v/05
Incorporating the following units:
2010-2-F1-MB
Main control board
ZP2-UI-SC
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
20 Oct 2014
Network board
Loop expansion board
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
193
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2010-SK
Scandinavian key and lock assembly
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Type A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
ZP2-F2
092v/06
2 Loop intelligent analogue addressable control and indicating equipment
Incorporating the following units:
2010-2-F2-MB
Main control board
ZP-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
Network board
Loop expansion board
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Type A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
3. Available in the following language variants:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
ZP2-F2-FB
2 Loop intelligent analogue addressable control and indicating equipment with fire alarm
routing output
092v/06
Incorporating the following units:
194
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2010-2-F2-MB
ZP2-UI-FB
2010-2-PS-40
Main control board
User interface control board with fire routing controls
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
Network board
Loop expansion board
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
3. Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
ZP2-F2-SC
2 Loop intelligent analogue addressable control and indicating equipment with
Scandinavian key switch
092v/06
Incorporating the following units:
2010-2-F2-MB
Main control board
ZP2-UI-SC
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-20
2X-ZI-40
2010-2-PS-C2
2010-SK
Network board
Loop expansion board
Interface Board for External Printer
20 zone LED indication board
40 zone LED indication board
UK mains cable
Scandinavian key and lock assembly
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
20 Oct 2014
195
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
ZP2-F1-S
092v/07
1 Loop intelligent analogue addressable fire control panel in small cabinet
Incorporating the following units:
2010-2-F1-MB
Main control board
ZP-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
Network board
2010-2-LB
Loop expansion board
2010-2-232-IB
Interface board for external printer
2X-ZI-24
24 zone LED indication board
2010-2-PS-C2
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
3. Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
ZP2-F1-FB-S
1 Loop intelligent analogue addressable fire control panel with fire alarm routing
equipment output in small cabinet
092v/08
Incorporating the following units:
2010-2-F1-MB
Main control board
ZP2-UI-FB
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
196
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
7.11
7.12
7.13
8.4
8.9
9.5
10
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
3. Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
ZP2-F1-SC-S
1 Loop intelligent analogue addressable fire control panel with fire alarm routing
equipment output and Scandinavian key in small cabinet
092v/09
Incorporating the following units:
2010-2-F1-MB
Main control board
ZP2-UI-SC
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
2010-SK
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Scandinavian key and lock assembly
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
3. Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
ZP2-F2-S
2 Loop intelligent analogue addressable fire control panel in small cabinet
092v/10
Incorporating the following units:
2010-2-F2-MB
Main control board
ZP-UI
User interface control board
2010-2-PS-40
4A Power Supply
and as optional modules:
20 Oct 2014
197
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
3. Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
ZP2-F2-FB-S
092v/11
2 Loop intelligent analogue addressable fire control panel with fire alarm routing
equipment output in small cabinet
Incorporating the following units:
2010-2-F2-MB
Main control board
ZP2-UI-FB
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
3. Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
198
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
ZP2-F2-SC-S
LPCB Ref.
No.
2 Loop intelligent analogue addressable fire control panel with fire alarm routing
equipment output and Scandinavian key
092v/12
Incorporating the following units:
2010-2-F2-MB
Main control board
ZP2-UI-SC
User interface control board with fire routing controls
2010-2-PS-40
4A Power Supply
2010-SK
Scandinavian key and lock assembly
and as optional modules:
2010-2-NB
2010-2-LB
2010-2-232-IB
2X-ZI-24
2010-2-PS-C2
Network board
Loop expansion board
Interface board for external printer
24 zone LED indication board
UK mains cable
Certified with the following options with requirements from EN 54-2:
7.8
7.9.1
7.9.2
7.10
7.11
7.12
7.13
8.4
8.9
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Alarm confirmation input from fire alarm routing equipment
Output to fire protection equipment (Types A, B and C)
Delays to outputs
Dependencies on more than one alarm signal (Types A, B and C)
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
Notes:
1. This product approval does not constitute compliance with the fire detection
and alarm systems requirements of EN 54-13.
2. Scope of approval does not include the operation of the network functionality.
Available with the following language kits:
01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,
24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International)
ZP2-FR
Addressable Fire Panel Repeater
092v/R01
Incorporating the following options with requirements from EN 54-2:
ZP2-FR-FB
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater with Output to Fire Routing Equipment
092v/R02
Incorporating the following options with requirements from EN 54-2:
ZP2-FR-SC
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater with Scandinavian Key
092v/R03
Incorporating the following options with requirements from EN 54-2:
7.13
8.4
8.9
9.5
10
20 Oct 2014
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
199
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
ZP2-FR-S
Addressable Fire Panel Repeater in small cabinet
LPCB Ref.
No.
092v/R04
Incorporating the following options with requirements from EN 54-2:
ZP2-FR-SC-S
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian
key in small cabinet
092v/R05
Incorporating the following options with requirements from EN 54-2:
ZP2-FR-FB-S
7.13
Alarm counter
8.4
Total loss of the power supply
8.9
Output to fault warning routing equipment
9.5
Disablement of addressable points
10
Test condition
Addressable Fire Panel Repeater with fire alarm routing equipment output in small
cabinet
092v/R06
Incorporating the following options with requirements from EN 54-2:
7.13
8.4
8.9
9.5
10
Alarm counter
Total loss of the power supply
Output to fault warning routing equipment
Disablement of addressable points
Test condition
UTC Fire & Security Inc. Trading as Edwards Systems Technology
129 North Main Street, Pittsfield, Maine 04967, USA
Tel: 941 739-42228
Website: www.fs.utc.com
Certificate No: 262z-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006.
Certificate No: 262ab to EN 54-2:1997+A1:2006 , EN 54-4::1997+A1:2002+A2:2006 and EN 54-16:2008
Certificated Products
EST3
Incorporating as modular units:
LPCB Ref.
No.
262ab/01
Annunciators
EST3 24 LED Annunciators
3-24Y
3-24Y Annunciator Bill of Materials
3-24Y-E
3-24Y Annunciator Bill of Materials
3-24R
3-24R Annunciator Bill of Materials
3-24R-E
3-24R Annunciator Bill of Materials
3-24G
3-24G Annunciator Bill of Materials
3-24G-E
3-24G Annunciator Bill of Materials
3-12RY
3-12RY Annunciator Bill of Materials
3-12RY-E
3-12RY Annunciator Bill of Materials
EST3 18 LED Annunciators
3-6/3S1G2Y
3-6/3S1G2Y Annunciator Bill of Materials
3-6/3S1G2Y-E
3-6/3S1G2Y Annunciator Bill of Materials
3-6/3S1GYR
3-6/3S1GYR Annunciator Bill of Materials
3-6/3S1GYR-E
3-6/3S1GYR Annunciator Bill of Materials
3-6/3S2RY
3-6/3S2RY Annunciator Bill of Materials
3-6/3S2RY-E
3-6/3S2RY Annunciator Bill of Materials
130322-03
3-6/3S2RY - Red-yellow-red, 6 triads - PCB
TH level BOM
EST3 Control-Display Switch/LEDs
3-12SY
3-12SY 12 Switch-Yellow Bill of Materials
3-12SY-E
3-12SY 12 Switch-Yellow Bill of Materials
200
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
3-12SR
3-12SR-E
3-12SG
3-12SG-E
3-12/S1GY
3-12/S1GY-E
3-12/S1RY
3-12/S1RY-E
3-12/S2Y
3-12/S2Y-E
3-12/S2R
3-12/S2R-E
3-12SR 12 Switch-Red Bill of Materials
3-12SR 12 Switch-Red Bill of Materials
3-12SG 12 Switch-Green Bill of Materials
3-12SG 12 Switch-Green Bill of Materials
3-12/S1GY 12 Switch-Green/Yellow
3-12/S1GY 12 Switch-Green/Yellow
3-12/S1RY 12 Switch-Red/Yellow Bill of Materials
3-12/S1RY 12 Switch-Red/Yellow Bill of Materials
3-12/S2Y - 12 Switches - 24 Yellow Bill of Materials
3-12/S2Y - 12 Switches - 24 Yellow Bill of Materials
3-12/S2R - 12 Switches - 24 Red Bill of Materials
3-12/S2R - 12 Switches - 24 Red Bill of Materials
Loop Controller Modules
3-SSDC1-E
Signature (Single), driver controller module
3-SDDC1-E
Signature (Dual), driver controller module
3-AADC1-E
System Sensor driver control module
3-SDC1-E
Signature, driver controller module
3-EAC-E
Edwards Analog Driver Card
3-EASC-E
Edwards (Single) Analogue driver controller module
3-EADC-E
Edwards (Dual) Analogue driver controller module
Power Supplies
3-PPS/M-230-E
3-BPS/M-230-E
3-BBC/M-230-E
3-PSMON-E
3-BPMON-E
3-BBCMON-E
3-CPU3
3-CPU3-E
3-LDSM
3-LDSM-E
3-IDC 8/4
3-IDC 8/4-E
3-LCD
3-LCD-E
3-LRMF
3-RS485A
3-RS485A-E
3-RS485B
3-RS485B-E
3-RS232
3-RS232-E
EFM-2
EFM-10
Primary Power Supply 230V
Booster Power Supply 230V
Booster, Battery Charger Power Supply 230V
Primary Power Supply Monitor
Booster Power Supply Monitor
Booster, Battery Charger Monitor
Central Processor Unit
Central Processor Unit
Annunciator strip support module
Annunciator strip support module
Initiating Device Circuits/NACS
Initiating Device Circuits/NACS
EST3 Main Display LCD, user interface
EST3 Main Display LCD, user interface
Local Rail Module Filler
Data Communication, Class A
Data Communication, Class A
Data Communication, Class B
Data Communication, Class B
Serial Communications Card (Printer, etc)
Serial Communications Card (Printer, etc)
Data Communications Filter - 2 Circuits
Data Communications Filter - 10 Circuits
Cabinets & Door Assemblies
3-CAB7B-E
Cabinet Back Box 3-CAB7B-E
3-CAB14B-E
Cabinet Back Box 3-CAB14B-E
3-CAB21B-E
Cabinet Back Box 3-CAB21B-E
Lobby Cabinet Assemblies
3-CAB7D(R)-E
3-CAB7D-E Door Assembly - (R) indicates red
3-CAB14D(R)-E
3-CAB14D-E Door Assembly - (R) indicates red
3-CAB21D(R)-E
3-CAB21D-E Door Assembly - (R) indicates red
Battery Cabinets
3-RCC7R-E
3-RCC14R-E
3-RCC21R-E
3-BTSEN-E
BC-1
3-TAMP
3-TAMPRCC
EST3 - CAB 7 Module Chassis - Remote Closet Cabinet
EST3 - CAB 14 Module Chassis - Remote Closet Cabinet
EST3 - CAB 21 Module Chassis - Remote Closet Cabinet
Remote battery cabinet interlace, temperature sensing
Battery Cabinet
Cabinet Tamper Switch for 3-CAB7/14/21
Tamper Switch for 3-RCC Cabinet
Audio & Telephone Common Controls - Chassis Assemblies
3-CHAS7
EST3 - CHASSIS 7 Module - Chassis Assy for 7 LRMs
3-CHAS7-E
EST3 - CHASSIS 7 Module - Chassis Assy for 7 LRMs
3-CHASS4
EST3 -CHASSIS 4 Mod - Chassis Assy for REMIC & 4 LRMs
3-CHASS4-E
EST3 -CHASSIS 4 Mod - Chassis Assy for REMIC & 4 LRMs
3-ASU-E
Audio Source Unit with a 3-Chassis - European
20 Oct 2014
201
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
3-ASU/4-E
3-ASUMX/100
3-ASU/FT-EN
3-FTCU-E
3-ZA20A
3-ZA20B
3-ZA20B-E
3-ZA40A
3-ZA40A-E
3-ZA40B
3-ZA40B-E
3-BATS
3-CBLKIT1
3-CPUDR
Audio Source Unit with 4 LRM slots - European
100 minute extended audio memory card
Audio Source Unit with Fire Fighter Tele - European
Firefighter Telephone Control Unit
20 watt Zone Amplifier, Class A
20 watt Zone Amplifier, Class B
20 watt Zone Amplifier, Class B
40 watt Zone Amplifier, Class A
40 watt Zone Amplifier, Class A
40 watt Zone Amplifier, Class B
40 watt Zone Amplifier, Class B
Battery Shelf for Single 65AH Cell
EST3 Extended Rail Cable Kit
EST3 CPU Door Kit
Certified with the following options with requirements from EN 54-2
7.8
7.13
8.3
10
Output to fire alarm devices
Alarm counter
Fault Signals from points
Test condition
Certified with the following options with requirements from EN 54-16
EST3 Repeater
EST3
7.3
Audible warning
7.4
Delay(s) to entering the voice alarm condition
7.5
Phased evacuation
7.6.2
Manual silencing of the voice alarm condition
7.7.2
Manual reset of the voice alarm condition
7.9
Voice alarm condition output
8.4
Indication of faults related to voice alarm zones
9
Disablement condition
10
Voice alarm manual control
12
Emergency microphone(s)
13.14
Redundant power amplifiers
Incorporating as modular units:
3-ANNCPU3
Remote Annunciator CPU with a 3-LCD
3-ANNSM
Remote (repeater) Annunciator Support Module
3-LCDANN-E
LCD Display and User Interface for Remote Annunciator
Annunciator Back Boxes and Doors Assemblies
3-10ANN-E
Remote Annunciator Back Box, 10 slots, with Door
3-10ANN/D-E
Inner/Outer Door Assembly for 3-10ANN-E
10ANN/B
Flush BackBox for 3-10ANN-E
10ANN/B-S
Surface BackBox for 3-10ANN-E
3-6ANN-E
Remote Annunciator Back Box, 6 slots, with Door
3-6ANN/D-E
Inner/Outer Door Assembly for 3-6ANN-E
6ANN/B
Flush BackBox for 3-6ANN-E
6ANN/B-S
Surface BackBox for 3-6ANN-E
3-4ANN-E
Remote Annunciator Back Box, 4 slots, with Door
3-4ANN/D-E
Inner/Outer Door Assembly for 3-4ANN-E
4ANN/B
Flush BackBox for 3-4ANN-E
4ANN/B-S
Surface BackBox for 3-4ANN-E
3-RLCM/D-E
EST3 Inner/Outer Door Assembly - Euro
RLCM/B
RLCM Flush BackBox
RLCM/B-S
RLCM Surface BackBox
3-REMICA-E
Remote paging Microphone - European
3-ANNCPU3
Remote Annunciator CPU with a 3-LCD
3-ANNSM
Remote (repeater) Annunciator Support Module
3-LCDANN-E
LCD Display and User Interface for Remote Annunciator
Incorporating as modular units:
3-SSDC1-E
3-SDDC1-E
3-AADC1-E
3-EASC-E
3-EADC-E
3-PPS/M-230-E
3-BPS/M-230-E
3-BBC/M-230-E
3-CPU3
EFM-2
202
262ab/R01
262z/01
Signature (Single), driver controller module
Signature (Dual), driver controller module
System Sensor driver control module
Edwards (Single) Analogue driver controller module
Edwards (Dual) Analogue driver controller module
Primary Power Supply
Booster Power Supply
Booster Battery Charger Power Supply
Central Processor Unit
Data Communications Filter
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
3-CAB7-E
3-CAB14-E
3-CAB21-E
7 Slot Cabinet
14 Slot Cabinet
21 Slot Cabinet
3-CAB7D(R)-E
3-CAB14D(R)-E
3-CAB21D(R)-E
3-RCC7R-E
3-RCC14R-E
3-RCC21R-E
3-LCD
3-BATSEN-E
3-BATSEN
3-BATS
3-RS485A
3-RS485B
3-RS232
3-PSMON
3-IDC8/4
3-24R
3-24Y
3-24G
3-12RY
3-12SR
3-12SY
3-12SG
3-12/S1GY
3-12/S1RY
3-12/S2Y
3-12/S2R
3-6/3S1G2Y
3-6/3S1GYR
3-6/3S2RY
3-BBCMON
3-BPSMON
3-LDSM
3-LRMF
3-RCIC
Door for 7 Slot Cabinet, (R) indicates red
Door for 14 Slot Cabinet, (R) indicates red
Door for 21 Slot Cabinet, (R) indicates red
Small Remote Battery Cabinet
Medium Remote Battery Cabinet
Large Remote Battery Cabinet
Liquid Crystal Display, user interface
Remote battery cabinet interface, temperature sensing
Remote battery cabinet interface
Battery Shelf
Data Communication, Class A
Data Communication, Class B
Serial Communications Card (Printer, etc)
Primary Power Supply Monitor
Initiating Device Circuits/NACS
24, Red
24, Yellow
24, Green
Red-over-yellow pairs
12 Switches. Red
12 Switches. Yellow
12 Switches. Green
12 Switches. Green over-yellow pairs
12 Switches. Red over-yellow pairs
24, Yellow, 12 Switches
24, Red, 12 Switches
Green-over-yellow-over-yellow triads, 6 triads
Green-over-yellow-over-red triads, 6 triads
Red-over-yellow-over-red triads, 6 triads
Booster, Battery Charger Monitor
Booster Power supply Monitor
Annunciator strip support module
Local Rail Module Filler
ASU Interconnect power and rail communication unit
Certified with the following options with requirements from EN 54 Part 2:
EST3 Repeater
7.8
Output to fire alarm devices
7.13
Alarm counter
8.3
Fault Signals from points
10
Test condition
Incorporating as modular units:
3-RS485BA
3-ANNCPU3
3-LCDANN-E
3-ANNSM
3-REMICA
3-24Y
3-12/S1GY
3-4ANN-E(R)
3-6ANN-E(R)
3-10ANN-E(R)
20 Oct 2014
262z/01R
Remote Annunciator RS485 Communications.
Remote Annunciator CPU
LCD Display and User Interface for Remote Annunciator
Remote (repeater) Annunciator Support Module
Remote paging Microphone.
24, Yellow.
12 Switches. Green over-yellow pairs.
Remote Annunciator Back Box, 4 slots, with Door (R)
indicates red
Remote Annunciator Back Box, 6 slots, with Door (R)
indicates red
Remote Annunciator Back Box, 10 slots, with Door (R)
indicates red
203
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Xtralis Pty Limited
4 North Drive, Virginia Park, 236-262 East Boundary Road, East Bentleigh, Victoria 3165, Australia
Tel: +61 3 9936 7001, +44 (0)1442 242330 • Fax: +61 3 9936 7201
E-mail: [email protected] • Website: www.xtralis.com
Certificate No: 681aq to EN 54-4: 1997 + A1: 2002 + A2: 2006
Power Supply Unit
Certificated Products
LPCB Ref.
No.
681aq/01
VPS-215-U
Power Supply Unit
Note: The unit is not intended to supply power to Fire Alarm Control Panels
VPS-220-U
Power Supply Unit
Note: The unit is not intended to supply power to Fire Alarm Control Panels
681aq/02
516-018-407
Power Supply Unit
Note: The unit is not intended to supply power to Fire Alarm Control Panels
681aq/03
Zarja Elektronika d.o.o
Polceva, Pot 1, 1240 Kamnik, Slovenia
Tel: +386 1831 7488 • Fax: +386 1831 7551
E-mail: [email protected] • Website: www.zarja.com
Certificate No: 1124a to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006
Control and indicating equipment
Certificated Products
NJP-400A
LPCB Ref.
No.
1124a/01
Analogue addressable and Conventional control and indicating equipment.
Incorporating the following units:
UPMO 400
NAMO 400
CPMO 400
Control and display module
Power supply module
Central processor module
Optional modules:
LIMO-Ap 400
Line module Apollo
LIMO-Ko 400
Line module conventional
VIMO 400
Input output module
IZMO 400 Output module
MRMO 400
Network module
Eng_pack English language kit
Slo_pack Slovenian language kit
Certified with the following options with requirements from EN 54-2:1997
204
7.8
7.9.1
7.10.1
7.10.2
7.11
8.3
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Output to fire protection equipment type A
Output to fire protection equipment type B
Delays to the auctioning of outputs
Fault signals from points
Disablement of each address point
Test condition
Notes:
1)
2)
Scope of approval does not include the operation of the network functionality.
This product approval does not constitute compliance with the fire detection
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
LPCB Ref.
No.
and alarm
NJP-401A
systems requirements of EN54-13.
Analogue addressable and Conventional control and indicating equipment.
1124a/02
Incorporating the following units:
UPMO 400
NAMO 401
CPMO 400
Control and display module
Power supply module
Central processor module
Optional modules:
LIMO-Ap 400
LIMO-Ko 400
VIMO 400
IZMO 400
MRMO 400
Eng_pack
Slo_pack
Line module Apollo
Line module conventional
Input output module
Output module
Network module
English language kit
Slovenian language kit
Certified with the following options with requirements from EN 54-2:1997
7.8
7.9.1
7.10.1
7.10.2
7.11
8.3
9.5
10
Output to fire alarm device(s)
Output to fire alarm routing equipment
Output to fire protection equipment type A
Output to fire protection equipment type B
Delays to the auctioning of outputs
Fault signals from points
Disablement of each address point
Test condition
Notes:
1)
Scope of approval does not include the operation of the network functionality.
2)
This product approval does not constitute compliance with the fire detection
and alarm
systems requirements of EN54-13.
Zeta Alarm Systems by GLT Exports Limited
Detection House, 72-78 Morfa Road, Swansea SA1 2EN, United Kingdom
Tel: +44 (0)1792 455175 • Fax: +44 (0)1792 455176
E-mail: [email protected] • Website: www.gltexports.com
Certificate No: 330d to EN 54: Part 2 and 4: 1997
Certificated Products
Premier SX
Premier SX
Premier SX
Premier MX 2
20 Oct 2014
2 zone conventional control and indicating equipment
4 zone conventional control and indicating equipment
8 zone conventional control and indicating equipment
Certified with the following options with requirements from EN 54: Part 2:
7.8
Output to fire alarm devices
7.11
Delays to the actioning of outputs
10
Test condition
2 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface (option)
Certified with the following options from EN 54: Part 2
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
LPCB Ref.
No.
330d/02
330d/03
330d/05
330d/06
205
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
Premier MX 4
Premier MX 8
Premier MX 16
Premier MX 32
Premier MX Repeater 8
Premier MX Repeater 16
Premier MX Repeater 32
4 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface (option)
Certified with the following options from EN 54: Part 2
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
8 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface (option)
Certified with the following options from EN 54: Part 2
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
16 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface (option)
Certified with the following options from EN 54: Part 2
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
32 zone conventional control and indicating equipment
Incorporating as modular units:
C1627 Mother board
C1629 Display board
C1632 16 Zone expansion board
C1652 5A Power Supply board
C1631 Repeater interface (option)
Certified with the following options from EN 54: Part 2
7.8
Output to fire alarm devices
7.9
Output to fire routing equipment
7.10
Output to automatic fire protection equipment
7.11
Delays to outputs
8.9
Output to fault warning equipment
10
Test condition
8 zone conventional repeater unit
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface
16 zone conventional repeater unit
Incorporating as modular units:
C1627 Mother board
C1628 Display board
C1631 Repeater interface
32 zone conventional repeater unit
Incorporating as modular units:
C1627 Mother board
C1629 Display board
C1631 Repeater interface
LPCB Ref.
No.
330d/07
330d/08
330d/09
330d/10
330d/R01
330d/R02
330d/R03
Certificate No: 018c to EN 54-2 and 4:1997
206
20 Oct 2014
PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products
Prem1er AL
20 Oct 2014
4 loop analogue addressable control and indicating equipment
Incorporating:
A1579 Motherboard
A1580 Display board
A1585 Loop cards
A1584 230V AC power supply control card
A1599 Printer board
Certified with the following options from EN 54-2: 1997
7.8
Output to fire alarm devices
7.11
Delays to outputs
8.3
Fault signals from points
9.5
Disablement of addressable points
10
Test condition
LPCB Ref.
No.
018c/01
207
PART 1: SECTION 3
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
WHY USE AN LPS 1014 APPROVED COMPANY?
Even with the best equipment, fire detection and alarm systems are only effective if correctly designed,
installed, commissioned and serviced. It is therefore important that specifiers select only competent firms with
a proven track record to undertake the work.
LPS 1014 Requirements for Certificated Fire Detection and Alarm System Firms meets these requirements in
full.
LPS 1014 requires one encompassing Certificate of Conformity for the project, i.e. single point responsibility,
which benefits all parties concerned, i.e. the insurer, the fire brigade, the building owner, etc. It is based on BS
5839-1 and also requires the use of third party approved products. For each system specifiers should request
the issue of an LPCB Certificate of Conformity as part of the contract which:

certifies that the fire detection and alarm system was designed, installed and commissioned in
accordance with the installation rules applied, and

ensures that the system is recorded by LPCB as a certificated fire detection and alarm installation.
The availability of more varied and sophisticated fire detection and alarm equipment means that it is even
more important that firms listed to LPS 1014 are regularly assessed by LPCB for their competence to design,
install, commission and service fire detection and alarm systems in accordance with acceptable installation
rules or codes of practice.
Additional offices
Where a firm has additional offices, each office must meet the requirements of LPS 1014 to be eligible for
certification, and is separately listed.
Provisional Approval
Firms with limited experience and track record can gain Provisional Approval in the LPS 1014 scheme. Their
work is closely monitored by LPCB and when they have completed the requisite number of fire detection and
alarm systems contracts over a period of not less than 2 years, and subject to satisfactory performance, they
will be given full approval and listed in this section of the Red Book.
Aarhus Fire Protection Limited
Aarhus House, 4 Moss Lane, Whitefield, Manchester M45 6HG, United Kingdom
Tel: +44 (0)161 767 8715 • Fax: +44 (0)161 767 8716
E-mail: [email protected] • Website: www.aarhusfire.co.uk
Certificate No. CFA-187 to LPS 1014
ADT Fire and Security
ADT House, Tannochside Park, Uddingston, Glasgow G71 5PH, United Kingdom
Tel: +44 (0)1698 486000 • Fax: +44 (0)1698 486100
Certificate No. CFA-113 to LPS 1014
208
20 Oct 2014
PART 1: SECTION 3
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
ADT Fire and Security
Tyco Park, Grimshaw Lane, Newton Heath, Manchester M40 2WL, United Kingdom
Tel: +44 (0)161 252 5500 • Fax: +44 (0)161 252 5688
Certificate No. CFA-109 to LPS 1014
ADT Fire and Security
ADT House, Mucklow Hill, Halesowen, Birmingham, West Midlands B62 8DA, United Kingdom
Tel: +44 (0)1212 556000 • Fax: +44 (0)1212 556100
Certificate No. CFA-108 to LPS 1014
ADT Fire and Security
180 Aztec West, Almondsbury, Bristol BS32 4TU, United Kingdom
Tel: +44 (0)1454 843434 • Fax: +44 (0)1454 843484
Certificate No. CFA-107 to LPS 1014
ADT Fire and Security
c/o Hindle Cockburns Ltd, Victoria Road, Leeds LS11 9SX, United Kingdom
Tel: +44 (0)1132 911000 • Fax: +44 (0)1132 425933
Certificate No. CFA-110 to LPS 1014
Alberta Fire & Security Equipment Limited
San Gwakkin Road, Mriehel, BKR 3000, Malta
Tel: +356 21 443538 • Fax: +356 21 484077
E-mail: [email protected] • Website: www.alberta.com.mt
Certificate No. CFA-177 to LPS 1014
Argus Fire Protection Company Limited
Hendglade House, 46 New Road, Stourbridge, West Midlands DY8 1PA, United Kingdom
Tel: +44 (0)1384 376256 • Fax: +44 (0)1384 393955
E-mail: [email protected] • Website: www.argusfire.co.uk
Certificate No. CFA-148 to LPS 1014
20 Oct 2014
209
PART 1: SECTION 3
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
Bailey Maintenance
7 Brown Lane West, Leeds LS12 6EH, United Kingdom
Tel: +44 (0)113 234 3443 • Fax: +44 (0)113 222 3925
E-mail: [email protected] • Website: www.baileymaintenance.co.uk
Certificate No. CFA-165 to LPS 1014
BBC Fire Protection Limited
St Florian House, Ayton Road, Wymondham, Norfolk NR18 0QH, United Kingdom
Tel: +44 (0)1953 857700 • Fax: +44 (0)1953 857750
E-mail: [email protected] • Website: www.bbcfire.co.uk
Certificate No. CFA-126 to LPS 1014
CAMS Fire & Security PLC
6 Wedgwood Court, Wedgwood Way, Pin Green Industrial Area, Stevenage, Hertfordshire SG1 4QR, United
Kingdom
Tel: +44 (0)1438 740840 • Fax: +44 (0)1438 737969
E-mail: [email protected] / [email protected] • Website: www.Camsfire.co.uk
Certificate No. CFA-190 to LPS1014
Chubb Fire & Security Limited
5 Canal Place, Armley Road, Leeds LS12 2DU, United Kingdom
Tel: +44 (0)113 235 5131 • Fax: +44 (0)113 235 5132
E-mail: [email protected] • Website: www.chubb.co.uk
Certificate No. CFA-120 to LPS 1014
Clymac Limited
Cloudway Court, Belton Road, Loughborough LE11 1LW, United Kingdom
Tel: +44 (0)1509 232651 • Fax: +44 (0)1509 232665
E-mail: [email protected] • Website: www.clymac.co.uk
Certificate No. CFA-154 to LPS 1014
CTM Fire and Security Limited
Unit 2, Osprey Place, Moss Side Industrial Estate, Leyland PR26 7EW, United Kingdom
Tel: +44 (0)800 5872753 • Fax: +44 (0)1772 641227
E-mail: [email protected] • Website: www.firealarmuk.com
Certificate No. CFA-156 to LPS 1014
210
20 Oct 2014
PART 1: SECTION 3
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
Daemon Fire and Security Limited
Daemon House, 41-42 Albert Road, Tamworth, Staffs B79 7JS, United Kingdom
Tel: +44 (0)1827 69266 • Fax: +44 (0)1827 53584
E-mail: [email protected]
Certificate No. CFA-145 to LPS 1014
Defensor Group Limited
Defensor House, 15 Kingsley Street, Leicester LE2 6DY, United Kingdom
Tel: +44 (0)116 244 8689 • Fax: +44 (0)116 244 8884
E-mail: [email protected]
Certificate No. CFA-161 to LPS 1014
Direction Fire Limited
Units 4 & 5 Fire Quarter, Blenheim Road, Epsom, Surrey KT19 9QN, United Kingdom
Tel: +44 (0)1372 744499 • Fax: +44 (0)1372 741188
E-mail: [email protected] • Website: www.directionfire.co.uk
Certificate No. CFA-178 to LPS 1014
EA-RS Group Limited
4 Swanbridge Industrial Park, Black Croft Road, Witham, Essex CM8 3YN, United Kingdom
Tel: +44 (0)1376 503680 • Fax: +44 (0)1376 511349
E-mail: [email protected] • Website: www.rs-fire.com
Certificate No. CFA-182 to LPS 1014
EMCOR Facilities Services Limited, EMCOR Specialist Services
Premier House, Tollgate, Eastleigh, Hampshire SO53 3YE, United Kingdom
Tel: +44 (0)2380 648028 • Fax: +44 (0)2380 648191
E-mail: [email protected] • Website: www.emcoruk.com
Certificate No. CFA-151 to LPS 1014
Emico Limited
Able House, 1 Figtree Hill, Hemel Hempstead, Hertfordshire HP2 5XL, United Kingdom
Tel: +44 (0)1442 213111 • Fax: +44 (0)1442 236945
E-mail: [email protected] • Website: www.emico.co
Certificate No. CFA-185 to LPS 1014
20 Oct 2014
211
PART 1: SECTION 3
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
Firetecnics Systems Limited
Firetecnics House, 328 St James's Road, London SE1 5JX, United Kingdom
Tel: +44 (0) 20 7587 0927 • Fax: +44 (0) 20 7740 3567
E-mail: [email protected] • Website: www.firetecnics.com
Certificate No. CFA-146 to LPS 1014
GBE Fire & Security (a division of GB Electronics Limited)
Unit C2, Elmbridge Court, Cheltenham Road East, Gloucester GL3 1JZ, United Kingdom
Tel: +44 (0)845 1220884 • Fax: +44 (0)845 1220885
E-mail: [email protected] • Website: www.gbe-uk.com
Certificate No. CFA-180 to LPS 1014
Global Fire Systems Limited trading as Global Fire & Security Systems
15 The Triangle, NG2 Business Park, Queens Drive, Nottingham NG2 1AE, United Kingdom
Tel: +44 (0)870 220 8211 • Fax: +44 (0)115 943 8999
E-mail: [email protected] • Website: www.globalfireandsecurity.co.uk
Certificate No. CFA-189 to LPS 1014
Grainger Fire Systems
Thornley House, Carrington Business Park, Carrington, Manchester M31 4XL, United Kingdom
Tel: +44 (0)161 777 6700 • Fax: +44 (0)161 777 6638
E-mail: [email protected]
The following location is included within the scope of certification for servicing:
Unit 1A, Newton Court, Wavertree Technology Park, Wavertree, Liverpool L13 1EJ
Tel: +44 (0)151 220 4068 • Fax: +44 (0)151 259 4365
Certificate No. CFA-125 to LPS 1014
Hall & Kay Fire Engineering (Ashford)
Littleton Road, Ashford, Middlesex TW15 1TZ, United Kingdom
Tel: +44 (0)1784 425949 • Fax: +44 (0)1784 424177
E-mail: [email protected] • Website: www.hkfire.co.uk
Certificate No. CFA-147 to LPS 1014
212
20 Oct 2014
PART 1: SECTION 3
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
I.C. Service & Maintenance Limited
Unit K3 Temple Court, Knights Park, Knight Road, Strood, Kent ME2 2LT, United Kingdom
Tel: +44 (0)1634 290300 • Fax: +44 (0)1634 290700
E-mail: [email protected] • Website: www.icservice.uk.com
Certificate No. CFA-158 to LPS 1014
Iceberg Building Services Limited
Unit 9, Honywood Business Park, Honywood Road, Basildon, Essex SS14 3HW, United Kingdom
Tel: +44 (0)1268 663900 • Fax: +44 (0)1268 663909
E-mail: [email protected] • Website: www.icebergbuildingservices.co.uk
Certificate No. CFA-175 to LPS 1014
Kingfell Engineering Limited
PO Box 64222, Barnby Street, London NW1 2RS, United Kingdom
Tel: +44 (0)203 2145252 • Fax: +44 (0)2032145253/5
E-mail: [email protected] • Website: www.kingfellengineering.com
Certificate No. CFA-138 to LPS 1014
Kingfisher Security (UK) Limited trading as Kingfisher Fire & Security
1 Riverside Industrial Estate, Dogflud Way, Farnham GU9 7UG, United Kingdom
Tel: +44 (0)1252 710809 • Fax: +44 (0)1252 710816
E-mail: [email protected] • Website: www.kingfishersecurity.co.uk
Certificate No. CFA-176 to LPS 1014
Lloret Fire and Security Limited
24 Ullswater Crescent, Ullswater Business Park, Coulsdon, Surrey CR5 2HR, United Kingdom
Tel: +44 (0) 208 410 4600 • Fax: +44 (0) 208 668 9141
E-mail: [email protected] • Website: www.lloret.co.uk
Certificate No. CFA-181 to LPS 1014
M. J. Quinn Integrated Services Limited
Oak House, Overbrook Lane, Knowsley Business Park, Knowsley, Merseyside L34 9FB, United Kingdom
Tel: +44 (0)151 547 8800 • Fax: +44 (0)151 547 8801
E-mail: [email protected] • Website: www.mjquinn.co.uk
Certificate No. CFA-137 to LPS 1014
20 Oct 2014
213
PART 1: SECTION 3
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
M. J. Quinn Integrated Services Limited
Finwell House, 26 Finsbury Square, London EC2A 1DS, United Kingdom
Tel: +44 (0)207 993 0731 • Fax: +44 (0)203 757 0580
E-mail: [email protected] • Website: www.mjquinn.co.uk
Certificate No. CFA-143 to LPS 1014
MECE Fire & Security Limited
Courtlodge, Kemsley Street Road, Bredhurst, Gillingham, Kent ME7 3LS, United Kingdom
Tel: +44 (0)1634 260607 • Fax: +44 (0)1634 260278
E-mail: [email protected] • Website: www.mecefireandsecurity.co.uk
Certificate No. CFA-159 to LPS 1014
Mercury Engineering
Mercury House, Sandyford Industrial Estate, Foxrock, Dublin 18, Ireland
Tel: +353 1 216 3000 • Fax: +353 1 216 3006
E-mail: [email protected] • Website: www.mercury.ie
Certificate No. CFA-174 to LPS 1014
MITIE Technical Facilities Management Limited
1st Floor Counting House, 53 Tooley Street, London SE1 2QN, United Kingdom
Tel: +44 (0)207 022 8300 • Fax: +44 (0)207 022 8301
E-mail: [email protected] • Website: www.mitie.com
Certificate No. CFA-129 to LPS 1014
MITIE Technical Facilities Management Limited (MITIE Fire and Security Systems)
MITIE House, 61-63 Kepler, Lichfield Road Industrial Estate, Tamworth B79 7XE, United Kingdom
Tel: +44 (0)1827 309791 • Fax: +44 (0)1827 313480
E-mail: [email protected] • Website: www.mitie.com
Certificate No. CFA-163 to LPS 1014
NG Bailey Limited - Rail Division
3rd Floor Angel Building, 407 St John's Street, London EC1V 4AB, United Kingdom
Tel: +44 (0)20 7843 0200 • Fax: +44 (0)20 7843 0201
E-mail: [email protected] • Website: www.ngbailey.co.uk
Certificate No. CFA-186 to LPS 1014
214
20 Oct 2014
PART 1: SECTION 3
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
PEL Services Limited
Belvue Business Centre, Belvue Road, Northolt, Middlesex UB5 5QQ, United Kingdom
Tel: +44 (0)20 8839 2100 • Fax: +44 (0)20 8841 1948
E-mail: [email protected] • Website: www.pel.co.uk
Certificate No. CFA-179 to LPS 1014
Protec Fire Detection plc
Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom
Tel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273
E-mail: [email protected] • Website: www.protec.co.uk
Including the following satellite offices:
Unit 4, White Oak Square, London Road, Swanley, Kent BB8 1AG, United Kingdom
Tel: +44 (0)845 456 5394 • Fax: +44 (0)845 456 5395
Unit 10, Fulcram 4, Solent Way, Whiteley, Fareham, Hampshire PO15 7FT, United Kingdom
Tel: +44 (0)845 456 5392 • Fax: +44 (0)845 456 5393
5 Morston Court, Blakeney Way, Kingswood Lakeside, Cannock, Staffordshire WS11 8JB, United Kingdom
Tel: +44 (0845 456 5398 • Fax: +44 (0845 456 5399
Unit 1, Ashfield Court, Whitehall Road, Leeds LS12 5JB, United Kingdom
Tel: +44 (0)845 456 53388 • Fax: +44 (0)845 456 53389
Certificate No. CFA-132 to LPS 1014
Scotshield Limited
Century House, Chapelhall Industrial Estate, Airdrie, Scotland ML6 8QH, United Kingdom
Tel: +44 (0)1236 767788 • Fax: +44 (0)1236 762233
E-mail: [email protected]
Including the following satellite office for service work only
Unit 2, 9 Lotland Street, Inverness ML1 8QH
Tel: +44 (0)1463 709637 • Fax: +44 (0)1463 709638
Certificate No. CFA-150 to LPS 1014
Sensetech Systems Limited
Langdale House, 11 Marshalsea Road, London SE1 1EN, United Kingdom
Tel: +44 (0)845 689 9099 • Fax: +44 (0)207 8633238
E-mail: [email protected] • Website: www.sensetechsystems.co.uk
Certificate No. CFA-184 to LPS 1014
20 Oct 2014
215
PART 1: SECTION 3
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
Siemens plc, Building Technologies, Fire Safety Division
Brunel House, Sir William Siemens Square, Frimley, Camberley, Surrey GU16 8QD, United Kingdom
Tel: +44 (0)1276 696000 • Fax: +44 (0)1276 696133
E-mail: [email protected] • Website: www.siemens.co.uk/buildingtechnologies
Certificate No. CFA-100 to LPS 1014
Static Systems Group Plc
Heath Mill Road, Wombourne, Staffordshire WV5 8AN, United Kingdom
Tel: +44 (0)1902 895551 • Fax: +44 (0)1902 324969
E-mail: [email protected] • Website: www.staticsystems.co.uk
Certificate No. CFA-135 to LPS 1014
T Clarke Public Limited Company
45, Moorfields, London EC2Y 9AE, United Kingdom
Tel: +44 (0)207 997 7400 • Fax: +44 (0)207 997 7405
E-mail: [email protected] • Website: www.tclarke.co.uk
Certificate No. CFA-188 to LPS 1014
T V F (UK) Limited
59-69 Queens Road, High Wycombe, Buckinghamshire HP13 6AH, United Kingdom
Tel: +44 (0)1494 450641 • Fax: +44 (0)1494 465378
E-mail: [email protected] • Website: www.tvfltd.co.uk
Certificate No. CFA-128 to LPS 1014
Thameside Fire Protection Co. Limited
Unit 4, Sovereign Business Park, Cranes Farm Road, Basildon, Essex SS14 3JD, United Kingdom
Tel: +44 (0)1268 597999 • Fax: +44 (0)1268 597998
E-mail: [email protected] • Website: www.thamesidefire.co.uk
Certificate No. CFA-171 to LPS 1014
Trinity Fire and Security Systems Ltd (Abingdon)
180D Park Drive Milton, Milton Park, Abingdon, Oxfordshire OX14 4SE, United Kingdom
Tel: +44 (0)1235 862456 • Fax: +44 (0)1235 834450
E-mail: [email protected] • Website: www.trinityprotection.co.uk
Certificate No. CFA-168 to LPS 1014
216
20 Oct 2014
PART 1: SECTION 3
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
Trinity Fire and Security Systems Ltd (Exeter)
Little Bridge Business Park, Oil Mill Lane, Clyst St.Mary, Exeter, Devon EX5 1AG, United Kingdom
Tel: +44 (0)1392 874455 • Fax: +44 (0)1392 875546
E-mail: [email protected] • Website: www.trinityprotection.co.uk
Certificate No. CFA-160 to LPS 1014
Trinity Fire and Security Systems Ltd (Honiley)
Unit C15b, Holly Farm Business Park, Honiley, Warwickshire CV8 INP, United Kingdom
Tel: +44 (0)1926 485080 • Fax: +44 (0)1926 485090
E-mail: [email protected] • Website: www.trinityprotection.co.uk
Certificate No. CFA-167 to LPS 1014
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated
Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)
Mucklow Office Park, Mucklow Hill, Halesowen, West Midlands B62 8DA, United Kingdom
Tel: +44 (0)121 255 6000 • Fax: +44 (0)121 255 6100
Website: www.tycofis.com
Certificate No. CFA-103 to LPS 1014
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated
Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)
1610 Park Avenue, Aztec West, Almondsbury, Bristol BS32 4UA, United Kingdom
Tel: +44 (0)1454 240071 • Fax: +44 (0)1454 626443
Website: www.tycofis.com
Certificate No. CFA-170 to LPS 1014
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated
Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)
Tyco House, 57-63 Farnham Road, Slough, Berkshire SL1 3TN, United Kingdom
Tel: +44 (0)1753 574111 • Fax: +44 (0)1753 824226
Website: www.tycofis.com
Certificate No. CFA-157 to LPS 1014
20 Oct 2014
217
PART 1: SECTION 3
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS
Vipond Fire Protection Limited
10-12 Glenfield Road, Kelvin Industrial Estate, East Kilbride, Lanarkshire G75 0RA, United Kingdom
Tel: +44 (0)1355 2375 25/80/88 • Fax: +44 (0)1355 263399
E-mail: [email protected] • Website: www.vipondfire.co.uk
Certificate No. CFA-173 to LPS 1014
218
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
There are many types of detectors on the market designed to work on different principles and fire parameters
(e.g. smoke, flame radiation, convective heat etc). The selection of a detector for a particular area or
application should be based on a number of factors including the following:



The nature of the fire hazard
The speed of response required
The need to minimize false alarms
There are other factors to be taken into account such as architecture of the building, ease of maintenance and
cost, etc.
Guidance on the selection of appropriate types of detectors should be sought from the applicable installation
rule or code of practice (e.g. BS 5839-1). Where a particular type of detector is not covered by the installation
rule or code of practice then guidance should be sought from the manufacturer’s literature. In any case,
account should be given to the notes or limitations given with the listed detector in this section.
This section lists fire detectors approved for use in fire detection and fire alarm systems in buildings.
The initial approval and continued approval processes for detectors are outlined in scheme document SD021.
The list includes detectors certified to recognised standards or to special test schedules which are developed
by LPCB for detector types where suitable standards are not available or were not available at the time of the
evaluation.
Products listed in this section have been approved to:
 EN 54-5: 2000 Heat detectors - point detectors
 EN 54-5: 2000 + A1: 2002 Heat detectors - point detectors
 EN 54-7: 2000 Smoke detectors - point detectors using scattered light, transmitted light or ionisation
 EN 54-7 :2000 +A1: 2002 and A2: 2006 Smoke detectors - point detectors using scattered light,
 transmitted light or ionisation
 EN 54-10: 2002 Flame detectors - point detectors
 EN 54-10: 2002 + A1: 2005 Flame detectors - point detectors
 EN 54-12: 2002 Smoke detectors - line detectors using an optical light beam
 EN 54-20: 2006 Aspirating smoke detectors
 EN 54-25: 2008 Components using radio links
 ISO7240-5: 2003 Point -type heat detectors
 ISO7240-6: 2004 Carbon monoxide fire detectors using electro-chemical cells
 ISO7240-7: 2003 Point-type smoke detectors using scattered light, transmitted light or ionization
 ISO7240-12: 2005 Line type smoke detectors using transmitting light beam
 ISO7240-15: 2004 Multisensor fire detectors
 ISO 7240-6: 2008 Carbon monoxide fire detectors using electro-chemical cells and heat sensors.
 CEA 4021: 1999 Requirements and test methods for multisensor detectors, which respond to smoke
and heat, and smoke detectors with more than one smoke sensor
 CEA 4021: 2003 Requirements and test methods for multisensor detectors, which respond to smoke
and heat, and smoke detectors with more than one smoke sensor
 LPS 1265-1.1: 2005 Requirements and Testing Procedures for the LPCB Approval and Listing of
Carbon Monoxide Fire Detectors Using Electrochemical Cells
 LPS 1274-1.0: 2005 Testing Procedures for the LPCB Approval and Listing of Carbon Monoxide
/Heat Multisensor Fire Detectors Using Electrochemical Cells
 LPS 1279-1.0: 2006 Testing Procedures for the LPCB Approval and Listing of Point Multisensor Fire
Detectors using Optical or Ionization Smoke Sensors and Electrochemical Cell CO Sensors and,
optionally, Heat Sensors
 LPS 1280-1.0: 2007 Testing Procedures for the LPCB Approval and Listing of Duct Smoke Detectors
using Point Smoke Detectors
20 Oct 2014
219
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Approval can also be obtained for other detection principles not detailed above. In such circumstances, LPCB
can develop test criteria to evaluate products, which in time may be used for the development of standards.
Audit:
Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing
standards and continued compliance with the applicable product standard.
Notes:
1. EN 54-5: 2000 is now a harmonised standard for the Construction Products Directive and CE marking is
required for most of the European market since 30 June 2005. It is therefore recommended that heat
detectors are certificated to EN 54-5: 2000 + A1: 2002
2.
EN 54-7: 2000 is now a harmonised standard for the Construction Products Directive and CE marking is
required for most of the European market since 30 June 2005. It is therefore recommended that smoke
detectors are certificated to EN 54-7: 2000 + A1: 2002 and A2: 2006
3. EN 54-10: 2002 is now a harmonised standard for the Construction Products Directive and CE marking is
required for most of the European market since 1 September 2008. It is therefore recommended that
flame detectors are certificated to EN 54- 10: 2002 + A1: 2005
4. EN 54-12: 2002 is now a harmonised standard for the Construction Products Directive and CE marking is
required for most of the European market since 31 December 2005. It is therefore recommended that
beam detectors are certificated to EN 54- 12: 2002
5. EN 54-25: 2008 is now a harmonised standard for the Construction Products Directive and CE marking is
required for most of the European market since 1 March 2011. It is therefore recommended that radio link
components are certificated to EN 54- 25: 2008
6. CEA 4021: 2003 supersedes CEA 4021: 1999 which was withdrawn in June 2003 (i.e. at the same time
as the national versions of EN 54-5: 1976 and EN 54-7: 1982 were officially withdrawn and replaced with
EN 54- 5: 2000 and EN 54-7: 2000).
7. EN 54-20: 2006 supersedes CEA 4022: 1999 which should have been withdrawn in 2009.
EN 54-20: 2006 is now a harmonised standard for the Construction Products Directive and CE marking is
required for most of the European market since 1 July 2009. It is therefore recommended that aspirating
detectors are certificated to EN 54-20: 2006.
8. The bases with which a detector has been evaluated and shown to meet the relevant standards are listed
with each detector. Bases are not approved/certificated in their own right unless they are combined with
another device (e.g. short circuit isolator or sounder).
9. Since LPCB uses national and international standards for the listing of products, in some instances the
requirements of these standards may conflict with the recommendations of local codes of practice. We
recommend that specifiers seek advice from the relevant local authorities and amend their specifications
accordingly.
ADI International
ADI International Espana, C/Vivero 5, 28040 Madrid, Spain
Tel: +34 91 102 590 • Fax: +34 91 535 0081
E-mail: [email protected] • Website: www.ademco.es
Certificate No: 199u to EN 54-12: 2002
Beam Detectors
Certificated Products
8200R
220
Conventional optical beam detector
Note:
LPCB Ref.
No.
199u/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
8200RS
LPCB Ref.
No.
1. Meets the requirements for EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 & Acclimate
levels 1 & 2
Conventional optical beam detector with self test facility
Note:
1. Meets the requirements for EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 & Acclimate
levels 1 & 2
199u/02
Advanced Electronics Limited
34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United Kingdom
Tel: +44 (0)1670 707 111 • Fax: +44 (0)1670 707 222
E-mail: [email protected] • Website: www.Advel.co.uk
Certificate No: 928a-(cl-5) to EN54-5: 2000 + A1: 2002 and EN 54 -17: 2005
Certificate No: 928d-(cl-5) to EN 54-5: 2000 + A1: 2002
Certificate No: 928j-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008
Point Heat Detectors
Certificated Products
20-V350-ADV
20-LV350-ADV
20-AS3500-ADV
20-SG350-ADV
Bases
20-AB100-ADV
20-VB100-ADV
20-ABR100-ADV
20-ABDR100-ADV
20-ABS100-ADV
20-ABSR100-ADV
20-ABSRD100-ADV
WAB100
Analogue addressable Class P heat detector with short circuit isolator (20-AB100-ADV
base)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B.
Analogue addressable Class P, temperature detector (20-VB100-ADV and 20-AB100ADV bases)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B.
Conventional Class P, heat detector (20-AB100-ADV, 20-ABR100-ADV,
20-ABDR100-ADV, 20-ABS100-ADV, 20-ABSR100-ADV and 20-ABSRD100-ADV)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B.
Wireless heat detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1R
2. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928a/01
928d/01
928d/02
928j/01
Mounting base
Mounting base (with link resistor)
Universal adaptor base with resistor
Universal adaptor base with resistor and Schottky diode
Deep adaptor base
Deep adaptor base with resistor
Deep adaptor base with resistor and Schottky diode
Wireless adaptor base
Certificate No: 928b-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005
Certificate No: 928e-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
20-V100-ADV
Analogue addressable photoelectric smoke detector with short circuit isolator (20-AB100ADV base)
LPCB Ref.
No.
928b/01
Note:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
20 Oct 2014
221
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Analogue addressable optical smoke detector (20-VB100-ADV and 20-AB100-ADV
bases)
20-LV100-ADV
Note:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Conventional photo smoke detector (20-AB100-ADV, 20-ABR100-ADV, 20-ABDR100ADV, 20-ABS100-ADV, 20-ABSR100-ADV and 20-ABSRD100-ADV)
20-AS1000-ADV
Bases
20-AB100-ADV
20-VB100-ADV
20-ABR100-ADV
20-ABDR100-ADV
20-ABS100-ADV
20-ABSR100-ADV
20-ABSRD100-ADV
928e/01
928e/02
Mounting base
Mounting base (with link resistor)
Universal adaptor base with resistor
Universal adaptor base with resistor and Schottky diode
Deep adaptor base
Deep adaptor base with resistor
Deep adaptor base with resistor and Schottky diode
Certificate No: 928c-(cl-5) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA4021: 2003
Certificate No: 928f-(cl-5) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Multi-sensor detectors
Certificated Products
20-V200-ADV
Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with
short circuit isolator (20-AB100-ADV base)
Notes:
1.
2.
3.
20-LV200-ADV
222
LPCB Ref.
No.
928c/01
Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following
settings:
Multi criteria level 1 (most sensitive) - thermally enhanced
smoke detection with Class A1 heat response
Multi criteria level 2 - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 3 - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 4 (least sensitive) - thermally enhanced
smoke detection with Class A1 heat response
Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Analogue addressable photo thermal multisensor (20-VB100-ADV and 20-AB100-ADV
bases)
Notes:
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following
settings:
Multi criteria level 1 (most sensitive) - thermally enhanced
smoke detection with Class A1 heat response
Multi criteria level 2 - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 3 - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 4 (least sensitive) - thermally enhanced
smoke detection with Class A1 heat response
2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
3. Meets the requirements of EN 54-7 at the following settings:
928f/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Bases
20-AB100-ADV
20-VB100-ADV
Mounting base
Mounting base (with link resistor)
Certificate No: 928k-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008
Smoke Detectors
Certificated Products
20-SG100-ADV
Wireless optical smoke detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-7 in the normal sensitivity setting
2. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928k/01
Bases:
WAB100 Wireless Adaptor Base
Certificate No: 928m-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
20-SG200-ADV
Wireless multi-criteria detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1
2. Meets the requirements of EN 54-7 in the normal sensitivity setting
3. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928m/01
Bases:
WAB100 Wireless Adaptor Base
Advantronic Systems S.L.
C/Yunque 9 Nave B1, Tres Cantos, Madrid 28760, Spain
Tel: +34 91 806 2343 • Fax: +34 91 803 1171
E-mail: [email protected] • Website: www.advantronic.es
Certificate No: 928a-(cl-3) to 54-5: 2000 + A1: 2002 and EN 54 -17: 2005
Certificate No: 928d-(cl-3) to EN 54-5: 2000 + A1: 2002
Certificate No: 928j-(cl-2) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008
Point Heat Detectors
Certificated Products
AT120A
AT120AS
AT120CM
ATW120A
20 Oct 2014
Analogue addressable Class P heat detector with short circuit isolator (BA100 base)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B.
Analogue addressable Class P, temperature detector (BA100 base)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B.
Conventional Class P, heat detector (BA100 and BA101 bases)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B.
Wireless heat detector (WAB100 base)
LPCB Ref.
No.
928a/01
928d/01
928d/02
928j/01
223
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
Notes:
1. Meets the requirements of EN 54-5 for Class A1R
2. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
Bases
BA100
BA101
WAB100
Mounting base
Deep adaptor base
Wireless Adaptor Base
Certificate No: 928b-(cl-3) to 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005
Certificate No: 928e-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
AT110A
Analogue addressable photoelectric smoke detector with short circuit isolator (BA100
base)
Note:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Analogue addressable optical smoke detector (BA100 base)
Note:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Conventional photo smoke detector (BA100 and BA101 bases)
AT110AS
AT110CM
Bases
BA100
BA101
LPCB Ref.
No.
928b/01
928e/01
928e/02
Mounting base
Deep adaptor base
Certificate No: 928c-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA4021: 2003
Certificate No: 928f-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Multi-sensor Detectors
Certificated Products
AT130A
Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with
short circuit isolator (BA100 base)
Notes:
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following
settings:
Multi criteria level 1 (most sensitive) - thermally enhanced
smoke detection with Class A1 heat response
Multi criteria level 2 - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 3 - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 4 (least sensitive) - thermally enhanced
smoke detection with Class A1 heat response
2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
3. Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
AT130AS
Analogue addressable photo thermal multisensor (BA100 base)
Notes:
224
LPCB Ref.
No.
928c/01
928f/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
1.
2.
3.
Bases
BA100
Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following
settings:
Multi criteria level 1 (most sensitive) - thermally enhanced
smoke detection with Class A1 heat response
Multi criteria level 2 - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 3 - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 4 (least sensitive) - thermally enhanced
smoke detection with Class A1 heat response
Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Mounting base
Certificate No: 928k-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008
Smoke Detectors
Certificated Products
ATW110A
Wireless optical smoke detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-7 in the normal sensitivity setting
2. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928k/01
Bases:
WAB100 Wireless Adaptor Base
Certificate No: 928m-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
ATW130A
Wireless multi-criteria detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1
2. Meets the requirements of EN 54-7 in the normal sensitivity setting
3. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928m/01
Bases:
WAB100 Wireless Adaptor Base
AGNI Devices PVT Ltd
C-55 DSIDC Ind Complex, Tilak Vihar, Tilak Nagar, New Delhi 110018, India
Tel: +91 11 28335624
E-mail: [email protected]
Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006
20 Oct 2014
225
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Smoke Detectors
Certificated Products
AD338-2L
Conventional photoelectric smoke detector (AD300 base)
LPCB Ref.
No.
550a/05
AD300 Standard Base
Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
AD338-2HL
Conventional photo-thermal class A1R detector (AD300 base)
Note: Meets the requirements of EN54-5: 2000 class A1R at pre-set sensitivity
LPCB Ref.
No.
550b/06
Base:
AD300 standard base
Certificate No: 550c to EN54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
AD318-2L
Conventional A1R rate of rise heat detector (AD300 base)
LPCB Ref.
No.
550c/08
Base:
AD300 standard base
Aguilera Electronica S.L
C / Julian Camarillo 26, Madrid 28037, Spain
Tel: +34 917545511 • Fax: +34 917545098
E-mail: [email protected]
Certificate No: 512d-(cl-2) to EN 54-5: 2000 + A1: 2002
Point Heat Detectors
Certificated Products
AE/C5-TV
Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
with LED output (P/N854001 base)
LPCB Ref.
No.
512d/04
Bases:
P/N854001 4-Wire detector base
Certificate No: 512a-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
AE/C5-OP
Conventional 2 wire photoelectric smoke detector with remote LED output (P/N854001
base)
LPCB Ref.
No.
512a/02
Bases:
P/N854001 4-Wire detector base
Certificate No: 512b-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A1: 2002 & CEA 4021: 2003
Multi-criteria Detectors
Certificated Products
AE/C5-OPT
226
Conventional 2 wire photoelectric smoke and heat detector with remote LED output
(P/N854001 base)
LPCB Ref.
No.
512b/02
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Bases:
P/N854001 4 Wire detector base
Alarm Supply Pte Ltd
63 Jalan Pemimpin, 03-07 Pemimpin Industrial Building, Singapore 577219, Singapore
Tel: +65 625 83445 • Fax: +65 625 86428
Certificate No: 512a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
EA318-2
EA318-2L
Conventional 2 wire photoelectric smoke detector (P/N852001 base)
Conventional 2 wire photoelectric smoke detector with remote LED output (E300-Base)
LPCB Ref.
No.
512a/01
512a/02
Bases:
E300-Base 4-wire detector base
P/N852001 2-wire detector base
Certificate No: 512d-(cl-1) to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
EA323-2
EA323-2L/A2R
Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
(P/N852001 base)
Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
with LED output (E300-Base)
LPCB Ref.
No.
512d/02
512d/04
Bases:
E300-Base 4-wire detector base
P/N852001 2-wire detector base
AMPAC Technologies PTY Ltd
7 Ledgar Road, Balcatta 6021, Australia
Tel: +618 (9242) 3333 • Fax: +618 (9242) 3334
E-mail: [email protected] • Website: www.ampac.net
Certificate No: 010ar to EN 54-5 : 2000 + A1: 2002
Certificate No: 010p-(cl-2) to EN54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
55000-465AMP
55000-475AMP
55000-122AMP
55000-127AMP
55000-132AMP
55000-137AMP
20 Oct 2014
Analogue addressable Class A2S heat detector
(45681-505AMP mounting bases)
Analogue addressable Classheat detector
(45681-505AMP mounting bases)
Series 65 Conventional Class A1R heat detector - Standard (45681-200AMP mounting
base) 1
Meets the requirements of EN54: Part 5 - Class A1R
Series 65 Conventional Class BR heat detector - Standard (45681-200AMP mounting
base) 1
Meets the requirements of EN54: Part 5 - Class BR
Series 65 Conventional Class CR heat detector - Standard (45681-200AMP mounting
base) 1
Meets the requirements of EN54: Part 5 - Class CR
Series 65 Conventional Class CS heat detector - Standard (45681-200AMP mounting
base) 1
Meets the requirements of EN54: Part 5 - Class CS
LPCB Ref.
No.
010ar/01
010ar/02
010p/06
010p/09
010p/12
010p/15
227
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Bases:
45681-505AMP Negative switching isolating base
45681-200AMP Series 60/65 mounting base
45681-201AMP Series 60/65 diode mounting base
45681-245AMP Series 65 relay mounting base
45681-246AMP Series 65 auxiliary relay mounting base
45681-247AMP Series 65 EOL 12 Volt mounting base
45681-248AMP Series 65 EOL 24 Volt mounting base
Notes:
1
Also certificated for use with 45681-245AMP, 45681-246AMP, 45681-247AMP, 45681-248AMP and 45681-201AMP mounting bases.
Certificate No: 010as to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 010q-(cl-2) to EN54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
55000-665AMP
55000-217AMP
55000-220AMP
55000-317AMP
Analogue addressable optical smoke detector
(45681-505AMP mounting bases)
Series 65 Conventional ionisation smoke detector - Standard (45681-200AMP mounting
base) 1
Series 65 Conventional integrating ionisation smoke detector - Standard (45681-200AMP
mounting base) 1
Series 65 Conventional optical smoke detector - Standard (45681-200AMP mounting
base) 1
LPCB Ref.
No.
010as/01
010q/06
010q/09
010q/12
Bases:
45681-505AMP Negative switching isolating base
45681-200AMP Series 60/65 mounting base
45681-201AMP Series 60/65 diode mounting base
45681-245AMP Series 65 relay mounting base
45681-246AMP Series 65 auxiliary relay mounting base
45681-247AMP Series 65 EOL 12 Volt mounting base
45681-248AMP Series 65 EOL 24 Volt mounting base
Notes:
1
Also certificated for use with 45681-245AMP, 45681-246AMP, 45681-247AMP, 45681-248AMP and 45681-201AMP mounting bases.
Certificate No: 010at to EN 54-17: 2005
Negative Switching Isolating Base
Certificated Products
45681-505AMP
Negative switching isolating base
LPCB Ref.
No.
010at/01
Certificate No: 010m-(cl-1) to EN54-7: 2001 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Certificate No: 010aq-(cl-1) to EN 54-5: 2000 + A1: 2002 + LPS 1274: 2005 + LPS 1265: 2004
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
58000-305AMP
Analogue addressable CO/heat multisensor detector
(45681-210AMP, standard intelligent mounting base)
Notes:
1.
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
2.
2002
228
LPCB Ref.
No.
010aq/01
Approved with the following mode configurations:30 ppm with high thermal enhancement (most sensitive)
33 ppm with CO only
40 ppm with low thermal enhancement (nominal sensitivity)
45 ppm with high thermal enhancement (least sensitive)
heat onlyA1R
Mode 1 , 3, and 4 are approved to LPS1274:2005 and EN 54-5:2000 + A1:
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
3.
4.
Mode 2 is approved to LPS 1265:2004
Mode 5 is approved to EN 54-5:2000 + A1:2002
Conditions of approval include;
55000-885AMP
a)
The 58000-305AMP should only be installed in accordance with the
manufacturers recommendations.
b)
The 58000-305AMP should not be set only as a carbon monoxide fire detector
where there is a specific risk of rapid burning/flaming fires.
c)
Refer to technical publication MAN3038-1 for limitations on the use of carbon
monoxide fire detection.
Analogue addressable multisensor detector (45681-209AMP and 45681-210AMP
mounting base)Approved with Apollo XP95 and S90 digital communication protocols that
have been configured for the XP95 multisensor detector in accordance with
manufacturers instructions.
010m/01
Bases:
45681-209AMP XP95/Discovery standard deep mounting base
45681-210AMP XP95 mounting base
Apollo Fire Detectors Limited
36 Brookside Road, Havant, Hampshire PO9 1JR, United Kingdom
Tel: +44 (0)2392 492412 • Fax: +44 (0)2392 492754
E-mail: [email protected]
Sales Enquiries Germany
Apollo Deutschland GmbH
Tel: +49 5241 330 60 • Fax: +49 5241 330 629
E-mail: [email protected]
Sales Enquiries Spain
Apollo Espana
Tel: +34 627 988 061 • Fax: +34 949 335 289
E-mail: [email protected]
Sales Enquiries China
Apollo Fire Detectors Limited, Shanghai representative office
Tel: +86 21 5237 0922 • Fax: +86 21 5237 0920
E-mail: [email protected]
Certificate No: 010r to EN 54: Part 5: 2000
Certificate No: 010ab to EN 54-5: 2000 + A1: 2002
Certificate No: 010p to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
XPA-HT-11170-APO
XPA-HT-11171-APO
20 Oct 2014
Xpander addressable radio linked Class A1R heat detector (XPA-WB-10022-APO
mounting base)
Notes:
1) Meets the requirements of EN 54-5 for Class A1R.
2) The complete radio base/detector combination is available as Apollo Part No.: XPACB-11170-APO.
3) The device must be used with the following batteries only:
  MN1500 LR6 - 1.5 volt alkaline AA cells.
4) The radio link functionality of this device is not included within the scope of approval.
Xpander addressable radio linked Class CS heat detector (XPA-WB-10022-APO
LPCB Ref.
No.
010ab/01
010ab/02
229
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
58000-400
55000-120
55000-121
55000-122
55000-125
55000-126
55000-127
55000-130
55000-131
55000-132
55000-135
55000-136
55000-137
230
LPCB Ref.
No.
mounting base)
Notes:
1) Meets the requirements of EN 54-5 for Class CS.
2) The complete radio base/detector combination is available as Apollo Part No.: XPACB-11171-APO.
3) The device must be used with the following batteries only:
 
MN1500 LR6 - 1.5 volt alkaline AA cells.
4) The radio link functionality of this device is not included within the scope of approval.
Discovery Analogue addressable heat detector (45681-209 and 45681-210 mounting
base)
Note: Meets the requirements of EN 54: Part 5 for the following settings
Class A1R in mode 1 and in conventional mode.
Class A2 in mode 2 and in conventional mode.
Class A2S in mode 3 and in conventional mode.
Class CR in mode 4 and in conventional mode.
Class CS in mode 5 and in conventional mode.
Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols when
the Discovery heat detector has been configured in accordance with manufacturer's
instructions.
Series 65 Conventional Class A1R heat detector - Flashing LED/Reed switch (45681-200
mounting base)
Note: Meets the requirements of EN 54: Part 5 - Class A1R
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Series 65 Conventional Class A1R heat detector - Flashing LED (45681-200 mounting
base)
Note: Meets the requirements of EN 54: Part 5 - Class A1R
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Series 65 Conventional Class A1R heat detector - Standard (45681-200 mounting base)
Note: Meets the requirements of EN 54: Part 5 - Class A1R
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Series 65 Conventional Class BR heat detector - Flashing LED/Reed switch (45681-200
mounting base)
Note: Meets the requirements of EN 54: Part 5 - Class BR
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Series 65 Conventional Class BR heat detector - Flashing LED (45681-200 mounting
base)
Note: Meets the requirements of EN 54: Part 5 - Class BR
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Series 65 Conventional Class BR heat detector - Standard (45681-200 mounting base)
Note: Meets the requirements of EN 54: Part 5 - Class BR
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Series 65 Conventional Class CR heat detector- Flashing LED/Reed switch (45681-200
mounting base)
Note: Meets the requirements of EN 54: Part 5 - Class CR
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Series 65 Conventional Class CR heat detector - Flashing LED (45681-200 mounting
base)
Note: Meets the requirements of EN 54: Part 5 - Class CR
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Series 65 Conventional Class CR heat detector - Standard (45681-200 mounting base)
Note: Meets the requirements of EN 54: Part 5 - Class CR
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Series 65 Conventional Class CS heat detector - Flashing LED/Reed switch (45681-200
mounting base)
Note: Meets the requirements of EN 54: Part 5 - Class CS
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Series 65 Conventional Class CS heat detector - Flashing LED (45681-200 mounting
base)
Note: Meets the requirements of EN 54: Part 5 - Class CS
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Series 65 Conventional Class CS heat detector - Standard (45681-200 mounting base)
010p/03
010p/04
010p/05
010p/06
010p/07
010p/08
010p/09
010p/10
010p/11
010p/12
010p/13
010p/14
010p/15
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
55000-400
55000-401
55000-420
55000-440
Orbis Class A1R
Orbis Class A2S
Orbis Class BR
LPCB Ref.
No.
Note: Meets the requirements of EN 54: Part 5 - Class CS
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
XP95 Analogue addressable Class A2S heat detector 45681-209 and 45681-210
mounting base)
Certificated with Apollo Discovery, XP95, and S90 digital communications protocols
configured for the Discovery heat detector in accordance with manufacturers instructions.
XP95 Analogue addressable Class CS heat detector 45681-209 and 45681-210
mounting base)
Certificated with Apollo Discovery, XP95, and S90 digital communications protocols
configured for the Discovery heat detector in accordance with manufacturers instructions.
XP95 Analogue addressable Class A2S heat detector 45681-209 and 45681-210
mounting base)
Certificated with Apollo Discovery, XP95, and S90 digital communications protocol
configured for the Discovery heat detector in accordance with manufacturers instructions.
XP95 IS Analogue addressable intrinsically safe Class A2S heat detector (45681-215
mounting base)
Certified with Apollo Series 90 and XP95 digital communications protocol
Heat detectors with Apollo Approval Reference* 00001 (Approved for use with base
styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base)
ORB-HT-11001-APO Orbis class A1R heat detector with SensAlert and FasTest
ORB-HT-11013-APO Orbis class A1R heat detector with Flashing LED, SensAlert and
FasTest
OAX-HT-11019-APO Orbis class A1R heat detector with SensAlert
OPX-HT-11025-APO Orbis class A1R heat detector with SensAlert
OEX-HT-11037-APO Orbis class A1R heat detector with Flashing LED and SensAlert
OIX-HT-11043-APO Orbis class A1R heat detector with Flashing LED and SensAlert
OMX-HT-11049-APO Orbis class A1R heat detector with SensAlert
OSX-HT-11061-APO Orbis class A1R heat detector with Flashing LED and SensAlert
OMX-HT-11071-APO Orbis class A1R heat detector with Flashing LED and SensAlert
OAX-HT-11077-APO Orbis class A1R heat detector with Flashing LED and SensAlert
OEX-HT-11089-APO Orbis class A1R heat detector with SensAlert
OSX-HT-11095-APO Orbis class A1R heat detector with SensAlert
OPX-HT-11125-APO Orbis class A1R heat detector with Flashing LED and SensAlert
OLX-HT-11137-APO Orbis class A1R heat detector with SensAlert and FasTest
Heat detectors with Apollo Approval Reference* 00002 (Approved for use with base
styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base)
ORB-HT-11002-APO Orbis class A2S heat detector with SensAlert and FasTest
ORB-HT-11014-APO Orbis class A2S heat detector with Flashing LED, SensAlert and
FasTest
OAX-HT-11020-APO Orbis class A2S heat detector with SensAlert
OPX-HT-11026-APO Orbis class A2S heat detector with SensAlert
OEX-HT-11038-APO Orbis class A2S heat detector with Flashing LED and SensAlert
OIX-HT-11044-APO Orbis class A2S heat detector with Flashing LED and SensAlert
OMX-HT-11050-APO Orbis class A2S heat detector with SensAlert
OSX-HT-11062-APO Orbis class A2S heat detector with Flashing LED and SensAlert
OMX-HT-11072-APO Orbis class A2S heat detector with Flashing LED and SensAlert
OAX-HT-11078-APO Orbis class A2S heat detector with Flashing LED and SensAlert
OEX-HT-11090-APO Orbis class A2S heat detector with SensAlert
OSX-HT-11096-APO Orbis class A2S heat detector with SensAlert
OPX-HT-11126-APO Orbis class A2S heat detector with Flashing LED and SensAlert
OLX-HT-11138-APO Orbis class A2S heat detector with SensAlert and FasTest
Heat detectors with Apollo Approval Reference* 00003 (Approved for use with base
styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base)
010p/20
010p/21
010p/22
010p/23
010r/01
010r/02
010r/03
ORB-HT-11003-APO Orbis class BR heat detector with SensAlert and FasTest
ORB-HT-11015-APO Orbis class BR heat detector with Flashing LED, SensAlert and
FasTest
OAX-HT-11021-APO Orbis class BR heat detector with SensAlert
OPX-HT-11027-APO Orbis class BR heat detector with SensAlert
OEX-HT-11039-APO Orbis class BR heat detector with Flashing LED and SensAlert
OIX-HT-11045-APO Orbis class BR heat detector with Flashing LED and SensAlert
OMX-HT-11051-APO Orbis class BR heat detector with SensAlert
OSX-HT-11063-APO Orbis class BR heat detector with Flashing LED and SensAlert
OMX-HT-11073-APO Orbis class BR heat detector with Flashing LED and SensAlert
OAX-HT-11079-APO Orbis class BR heat detector with Flashing LED and SensAlert
OEX-HT-11091-APO Orbis class BR heat detector with SensAlert
OSX-HT-11097-APO Orbis class BR heat detector with SensAlert
OPX-HT-11127-APO Orbis class BR heat detector with Flashing LED and SensAlert
OLX-HT-11139-APO Orbis class BR heat detector with SensAlert and FasTest
20 Oct 2014
231
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
Orbis Class BS
Orbis Class CR
Orbis Class CS
Orbis Class A1S
Orbis IS Class A1R
Orbis IS Class A2S
Heat detectors with Apollo Approval Reference* 00004 (Approved for use with base
styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base
ORB-HT-11004-APO Orbis class BS heat detector with SensAlert and FasTest
ORB-HT-11016-APO Orbis class BS heat detector with Flashing LED, SensAlert and
FasTest
OAX-HT-11022-APO Orbis class BS heat detector with SensAlert
OPX-HT-11028-APO Orbis class BS heat detector with SensAlert
OEX-HT-11040-APO Orbis class BS heat detector with Flashing LED and SensAlert
OIX-HT-11046-APO Orbis class BS heat detector with Flashing LED and SensAlert
OMX-HT-11052-APO Orbis class BS heat detector with SensAlert
OSX-HT-11064-APO Orbis class BS heat detector with Flashing LED and SensAlert
OMX-HT-11074-APO Orbis class BS heat detector with Flashing LED and SensAlert
OAX-HT-11080-APO Orbis class BS heat detector with Flashing LED and SensAlert
OEX-HT-11092-APO Orbis class BS heat detector with SensAlert
OSX-HT-11098-APO Orbis class BS heat detector with SensAlert
OPX-HT-11128-APO Orbis class BS heat detector with Flashing LED and SensAlert
OLX-HT-11140-APO Orbis class BS heat detector with SensAlert and FasTest
Heat detectors with Apollo Approval Reference* 00005 (Approved for use with base
styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base
ORB-HT-11005-APO Orbis class CR heat detector with SensAlert and FasTest
ORB-HT-11017-APO Orbis class CR heat detector with Flashing LED, SensAlert and
FasTest
OAX-HT-11023-APO Orbis class CR heat detector with SensAlert
OPX-HT-11029-APO Orbis class CR heat detector with SensAlert
OEX-HT-11041-APO Orbis class CR heat detector with Flashing LED and SensAlert
OIX-HT-11047-APO Orbis class CR heat detector with Flashing LED and SensAlert
OMX-HT-11053-APO Orbis class CR heat detector with SensAlert
OSX-HT-11065-APO Orbis class CR heat detector with Flashing LED and SensAlert
OMX-HT-11075-APO Orbis class CR heat detector with Flashing LED and SensAlert
OAX-HT-11081-APO Orbis class CR heat detector with Flashing LED and SensAlert
OEX-HT-11093-APO Orbis class CR heat detector with SensAlert
OSX-HT-11099-APO Orbis class CR heat detector with SensAlert
OPX-HT-11129-APO Orbis class CR heat detector with Flashing LED and SensAlert
OLX-HT-11141-APO Orbis class CR heat detector with SensAlert and FasTest
Heat detectors with Apollo Approval Reference* 00006 (Approved for use with base
styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base
ORB-HT-11006-APO Orbis class CS heat detector with SensAlert and FasTest
ORB-HT-11018-APO Orbis class CS heat detector with Flashing LED, SensAlert and
FasTest
OAX-HT-11024-APO Orbis class CS heat detector with SensAlert
OPX-HT-11030-APO Orbis class CS heat detector with SensAlert
OEX-HT-11042-APO Orbis class CS heat detector with Flashing LED and SensAlert
OIX-HT-11048-APO Orbis class CS heat detector with Flashing LED and SensAlert
OMX-HT-11054-APO Orbis class CS heat detector with SensAlert
OSX-HT-11066-APO Orbis class CS heat detector with Flashing LED and SensAlert
OMX-HT-11076-APO Orbis class CS heat detector with Flashing LED and SensAlert
OAX-HT-11082-APO Orbis class CS heat detector with Flashing LED and SensAlert
OEX-HT-11094-APO Orbis class CS heat detector with SensAlert
OSX-HT-11100-APO Orbis class CS heat detector with SensAlert
OPX-HT-11130-APO Orbis class CS heat detector with Flashing LED and SensAlert
OLX-HT-11142-APO Orbis class CS heat detector with SensAlert and FasTest
Heat detectors with Apollo Approval Reference* 00009 (Approved for use with base
styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base
ORB-HT-11166-APO Orbis class A1S heat detector with SensAlert and FasTest
ORB-HT-11167-APO Orbis class A1S heat detector with Flashing LED, SensAlert and
FasTest
Intrinsically safe heat detectors with Apollo Approval Reference* 50001 (Approved for
use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base
ORB-HT-51145-APO Orbis intrinsically safe class A1R heat detector with SensAlert and
FasTest
ORB-HT-51146-APO Orbis intrinsically safe class A1R heat detector with Flashing LED,
SensAlert and FasTest
Intrinsically safe heat detectors with Apollo Approval Reference* 50002 (Approved for
use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base
LPCB Ref.
No.
010r/04
010r/05
010r/06
010r/07
010r/08
010r/09
ORB-HT-51147-APO Orbis intrinsically safe class A2S heat detector with SensAlert and
FasTest
232
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
Orbis IS Class BR
Orbis IS Class BS
Orbis IS Class CR
Orbis IS Class CS
Orbis IS Class A1S
LPCB Ref.
No.
ORB-HT-51148-APO Orbis intrinsically safe class A2S heat detector with Flashing LED,
SensAlert and FasTest
Intrinsically safe heat detectors with Apollo Approval Reference* 50003 (Approved for
use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base
ORB-HT-51149-APO Orbis intrinsically safe class BR heat detector with SensAlert and
FasTest
ORB-HT-51150-APO Orbis intrinsically safe class BR heat detector with Flashing LED,
SensAlert and FasTest
Intrinsically safe heat detectors with Apollo Approval Reference* 50004 (Approved for
use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base
ORB-HT-51151-APO Orbis intrinsically safe class BS heat detector with SensAlert and
FasTest
ORB-HT-51152-APO Orbis intrinsically safe class BS heat detector with Flashing LED,
SensAlert and FasTest
Intrinsically safe heat detectors with Apollo Approval Reference* 50005 (Approved for
use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base
ORB-HT-51153-APO Orbis intrinsically safe class CR heat detector with SensAlert and
FasTest
ORB-HT-51154-APO Orbis intrinsically safe class CR heat detector with Flashing LED,
SensAlert and FasTest
Intrinsically safe heat detectors with Apollo Approval Reference* 50006 (Approved for
use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base)
ORB-HT-51155-APO Orbis intrinsically safe class CS heat detector with SensAlert and
FasTest
ORB-HT-51156-APO Orbis intrinsically safe class CS heat detector with Flashing LED,
SensAlert and FasTest
Intrinsically safe heat detectors with Apollo Approval Reference* 50009 (Approved for
use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base
010r/10
010r/11
010r/12
010r/13
010r/14
ORB-HT-51157-APO Orbis intrinsically safe class A1S heat detector with SensAlert and
FasTest
ORB-HT-51158-APO Orbis intrinsically safe class A1S heat detector with Flashing LED,
SensAlert and FasTest
Bases:
45681-200 Series 60 mounting base
45681-200 Series 60/65 Mounting Base
45681-201 Series 60 diode mounting base
45681-201 Series 60/65 Diode Mounting Base
45681-207 Series 60 intrinsically safe mounting base
45681-209 XP95/Discovery standard deep mounting base
45681-210 XP95 mounting base
45681-215 XP95 intrinsically safe mounting base
45681-245 Series 65 Relay mounting base
45681-246 Series 65 Auxiliary relay mounting base
45681-247 Series 65 EOL 12 Volt mounting base
45681-248 Series 65 EOL 24 Volt mounting base
TimeSaver bases with Apollo Approval Reference* OB
TimeSaver LX bases with Apollo Approval Reference* OL
TimeSaver diode bases with Apollo Approval Reference* OD
TimeSaver relay bases with Apollo Approval Reference* OR
TimeSaver LX diode bases with Apollo Approval Reference* DX
TimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking)
TimeSaver deep bases with Apollo Approval Reference*
EB: ORB-MB-00019-APO TimeSaver deep base
ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207)
ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201)
XPA-WB-10022-APO Radio link mounting base**
* The Apollo ‘Approval Reference Number’ identifies a group of detectors that all have the same physical construction, but have features
enabled or disabled via their software, and/or regional marking variations.
**Base manufactured by EMS
20 Oct 2014
233
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 010q to EN 54: Part 7: 2000
Certificate No: 010s to EN 54: Part 7: 2000
Certificate No: 010ac to EN 54-7: 2000 + A1: 2002
Smoke Detectors
Certificated Products
XPA-OP-12034-APO
58000-500 Discovery
58000-600 Discovery
55000-215 Series 65
55000-216 Series 65
55000-217 Series 65
55000-218 Series 65
55000-219 Series 65
55000-220 Series 65
55000-315 Series 65
55000-316 Series 65
55000-317 Series 65
55000-500 XP95
55000-520 XP95
55000-600 XP95
234
Xpander addressable radio linked photoelectric smoke detector (XPA-WB-10022-APO
mounting base)
Notes:
1) The complete radio base/detector combination is available as Apollo Part No.: XPACB-12034-APO.
2) The device must be used with the following batteries only:

MN1500 LR6 - 1.5 volt alkaline AA cells.
3) The radio link functionality is not included within the scope of approval.
Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting
base)2
Note: Meets the requirements of EN 54:Part 7 in modes 1, 2, 3, 4, 5 and in conventional
mode. Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols
that have been configured for the Discovery ionisation smoke detectors has been
configured in accordance with manufacturer's instructions.
Analogue addressable photoelectric smoke detector (45681-209 and 45681-210
mounting base)2
Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that
have been configured for the Discovery optical smoke detectors in accordance with
manufacturers instructions.
Conventional ionisation smoke detector - Flashing LED/Reed switch (45681-200
mounting base)
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Conventional ionisation smoke detector - Flashing LED (45681-200 mounting base)
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Conventional ionisation smoke detector - Standard (45681-200 mounting base)
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Conventional integrating ionisation smoke detector - Flashing LED/Reed switch (45681200 mounting base)
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Conventional integrating ionisation smoke detector - Flashing LED (45681-200 mounting
base)
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Conventional integrating ionisation smoke detector - Standard (45681-200 mounting
base)
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Conventional optical smoke detector - Flashing LED/Reed switch (45681-200 mounting
base)
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Conventional optical detector - Flashing LED (45681-200 mounting base)
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Conventional optical smoke detector - Standard (45681-200 mounting base)
Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases
Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting
base) 2
Certificated with Apollo Discovery, XP95, and S90 digital communication protocols
that have been configured for the Discovery ionisation smoke detectors in accordance
with manufacturers instructions .
Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting
base) 2
Certificated with Apollo Discovery, XP95, and S90 digital communication protocols
that have been configured for the Discovery ionisation smoke detectors in accordance
with manufacturers instructions .
Analogue addressable optical smoke detector (45681-209 and 45681-210 mounting
base) 2
LPCB Ref.
No.
010ac/01
010q/02
010q/03
010q/04
010q/05
010q/06
010q/07
010q/08
010q/09
010q/10
010q/11
010q/12
010q/16
010q/17
010q/18
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
55000-620 XP95
55000-560 XP95
55000-660 XP95
55000-640 XP95 IS
55000-540 XP95 IS
Orbis
Orbis IS
LPCB Ref.
No.
Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that
have been configured for the Discovery optical smoke detectors in accordance with
manufacturers instructions.
Analogue addressable optical smoke detector (45681-209 and 45681-210 mounting
base) 2
Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that
have been configured for the Discovery optical smoke detectors in accordance with
manufacturers instructions.
Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting
base) 2
Certificated with Apollo Discovery, XP95, and S90 digital communication protocols
that have been configured for the Discovery ionisation smoke detectors in accordance
with manufacturers instructions .
Analogue addressable optical smoke detector (45681-209 and 45681-210 mounting
base)2
Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that
have been configured for the Discovery optical smoke detectors in accordance with
manufacturers instructions.
Analogue addressable intrinsically safe optical smoke detector (45681-215 mounting
base)
Certified with Apollo Series 90 and XP95 digital communications protocol
Analogue addressable intrinsically safe ionisation smoke detector (45681-215 mounting
base)
Certified with Apollo Series 90 and XP95 digital communications protocol
Optical smoke detectors with Apollo Approval Reference* 00007 (Approved for use with
base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base)
ORB-OP-12001-APO Orbis optical smoke detector with SensAlert, FasTest and DirtAlert
ORB-OP-12003-APO Orbis optical smoke detector with Flashing LED, SensAlert,
FasTest and DirtAlert
OAX-OP-12004-APO Orbis optical smoke detector with SensAlert
OPX-OP-12005-APO Orbis optical smoke detector with SensAlert and DirtAlert
OEX-OP-12007-APO Orbis optical smoke detector with Flashing LED and SensAlert
OIX-OP-12008-APO Orbis optical smoke detector with Flashing LED, SensAlert and
DirtAlert
OMX-OP-12009-APO Orbis optical smoke detector with SensAlert and DirtAlert
OSX-OP-12011-APO Orbis optical smoke detector with Flashing LED and SensAlert
OMX-OP-12013-APO Orbis optical smoke detector with Flashing LED, SensAlert and
DirtAlert
OAX-OP-12014-APO Orbis optical smoke detector with Flashing LED and SensAlert
OEX-OP-12016-APO Orbis optical smoke detector with SensAlert
OSX-OP-12017-APO Orbis optical smoke detector with SensAlert
OPX-OP-12023-APO Orbis optical smoke detector with Flashing LED, SensAlert and
DirtAlert
OLX-OP-12025-APO Orbis optical smoke detector with SensAlert and FasTest
Intrinsically safe optical smoke detectors with Apollo Approval Reference* 50007
(Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008-APO
adapter base
010q/19
010q/20
010q/21
010q/22
010q/23
010s/01
010s/02
ORB-OP-52027-APO Orbis intrinsically safe optical smoke detector with SensAlert,
FasTest and DirtAlert
ORB-OP-52028-APO Orbis intrinsically safe optical smoke detector with Flashing LED,
SensAlert, FasTest and DirtAlert
Bases:
45681-200 Series 60 mounting base
45681-200 Series 60/65 Mounting Base
45681-201 Series 60 diode mounting base
45681-201 Series 60/65 Diode Mounting Base
45681-207 Series 60 intrinsically safe mounting base
45681-209 XP95/Discovery standard deep mounting base
45681-210 XP95 mounting base
45681-215 XP95 intrinsically safe mounting base
45681-245 Series 65 Relay mounting base
45681-246 Series 65 Auxiliary mounting base
45681-247 Series 65 EOL 12 Volt mounting base
45681-248 Series 65 EOL 24 Volt mounting base
45681-500 XPlorer standard mounting base
45681-501 XPlorer remote LED mounting base
TimeSaver bases with Apollo Approval Reference* OB
TimeSaver LX bases with Apollo Approval Reference* OL
TimeSaver diode bases with Apollo Approval Reference* OD
20 Oct 2014
235
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
TimeSaver relay bases with Apollo Approval Reference* OR
TimeSaver LX diode bases with Apollo Approval Reference* DX
TimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking)
ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207)
ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201)
XPA-WB-10022-APO Radio link mounting base**
* The Apollo ‘Approval Reference Number’ identifies a group of detectors that all have the same physical construction, but have features
enabled or disabled via their software, and/or regional marking variations.
**Base manufactured by EMS
Certificate No: 010h to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 & CEA 4021:2003
Certificate No: 010m to EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003
Certificate No: 010t to EN 54-7: 2000 & CEA 4021: 1999-06
Certificate No: 010ad to EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
XPA-OH-13032-APO
58000-700 Discovery
55000-885
Orbis
Orbis IS
Xpander addressable radio linked photoelectric multisensor smoke detector (XPA-WB10022-APO mounting base)
Notes:
1) The complete radio base/detector combination is available as Apollo Part No.: XPACB-13032-APO.
2) The device must be used with the following batteries only:
 
MN1500 LR6 - 1.5 volt alkaline AA cells.
3) The radio link functionality is not included within the scope of approval.
Analogue addressable multisensor detector (45681-209 and 45681-210 mounting base)
Note: Certificated at the following settings.
Mode 1 - High sensitivity smoke detector with standard heat enhancement.
Mode 2 - Smoke detection only.
Mode 3 - Medium sensitivity smoke detector with standard heat enhancement.
Mode 4 - Low sensitivity smoke detector with high heat enhancement.
Mode 5 - Class A1 heat detector.
Also Certificated in conventional alarm modes 1, 2, 3, 4 and 5.
Certificated with Discovery XP95 and S90 digital communication protocols that have
been configured for the Discovery multisensor detector in accordance with
manufacturer's instructions.
XP95 Analogue addressable multisensor detector (45681-209 and 45681-210 mounting
base)
Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols that
have been configured for the Discovery multisensor detector
in accordance with manufacturer's instructions.
Multisensor smoke detectors with Apollo Approval Reference* 00008 for use with base
styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base)
ORB-OH-13001-APO Orbis multisensor smoke detector with SensAlert, FasTest and
DirtAlert
ORB-OH-13003-APO Orbis multisensor smoke detector with Flashing LED, SensAlert,
FasTest and DirtAlert
OAX-OH-13004-APO Orbis multisensor smoke detector with SensAlert
OPX-OH-13005-APO Orbis multisensor smoke detector with SensAlert and DirtAlert
OEX-OH-13007-APO Orbis multisensor smoke detector with Flashing LED and
SensAlert
OIX - OH-13008-APO Orbis multisensor smoke detector with Flashing LED, SensAlert
and DirtAlert
OMX-OH-13009-APO Orbis multisensor smoke detector with SensAlert and DirtAlert
OSX-OH-13011-APO Orbis multisensor smoke detector with Flashing LED and
SensAlert
OMX-OH-13013-APO Orbis multisensor smoke detector with Flashing LED, SensAlert
and DirtAlert
OAX-OH-13014-APO Orbis multisensor smoke detector with Flashing LED and
SensAlert
OEX-OH-13016-APO Orbis multisensor smoke detector with SensAlert
OSX-OH-13017-APO Orbis multisensor smoke detector with SensAlert
OPX-OH-13023-APO Orbis multisensor smoke detector with Flashing LED, SensAlert
and DirtAlert
OLX-OH-13025-APO Orbis multisensor smoke detector with SensAlert and FasTest
Intrinsically safe multisensor detectors with Apollo Approval Reference* 50008
(Approved for use with base styles OB (+ATEX marking) and ORB-MB-50008-APO
adapter base)
LPCB Ref.
No.
010ad/01
010h/01
010m/01
010t/01
010t/02
ORB-OH-53027-APO Orbis intrinsically safe multisensor detector with SensAlert,
236
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
FasTest and DirtAlert
ORB-OH-53028-APO Orbis intrinsically safe multisensor detector with Flashing LED,
SensAlert, FasTest and DirtAlert
Bases:
45681-209 XP95/Discovery standard deep mounting base
45681-210 XP95 mounting base
TimeSaver bases with Apollo Approval Reference* OB
TimeSaver LX bases with Apollo Approval Reference* OL
TimeSaver diode bases with Apollo Approval Reference* OD
TimeSaver relay bases with Apollo Approval Reference* OR
TimeSaver LX diode bases with Apollo Approval Reference* DX
TimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking)
ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207)
ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201)
XPA-WB-10022-APO Radio link mounting base**
* The Apollo ‘Approval Reference Number’ identifies a group of detectors that all have the same physical construction, but have features
enabled or disabled via their software, and/or regional marking variations.
**Base manufactured by EMS
Certificate No: 010an to EN 54-10: 2002 + A1:2005
Flame Detectors
Certificated Products
55000-022
55000-023
55000-024
55000-025
55000-019
55000-060
55000-061
55000-062
55000-063
55000-064
55000-065
55000-282
55000-020
55000-021
55000-280
55000-295
20 Oct 2014
XP95 intelligentflame detector (45681-209 and 45681-210)
Note: Meets EN 54-10: 2002 at Class 1 and Class 3
XP95 intelligent 2 flame detectorand 45681-210)
Note: Meets EN 54-10: 2002 at Class 1 and Class 3
XP95 intelligent 3 flame detectorand 45681-210)
Note: Meets EN 54-10: 2002 at Class 1 and Class 3
S65 conventional UV flame detector (45681-200 and 45681-201)
Note: Meets EN 54-10: 2002 at Class 1 and Class 3
Conventional IR 3 Flame Detector (29600-203)
Note:
Meets EN 54-10: 2002 at Class 1 only
Conventional IR² Flame Detector (29600-203)
Note:
Meets EN 54-10: 2002 at Class 1 only
Conventional IR² (Exd) Flameproof Flame Detector (29600-203)
Note:
Meets EN 54-10: 2002 at Class 1 only
Conventional IR 3 (Exd) Flameproof Flame Detector (29600-203)
Note:
Meets EN 54-10: 2002 at Class 1 only
Conventional IR 3 Intrinsically Safe Flame Detector (29600-203)
Note:
Meets EN 54-10: 2002 at Class 1 only
Conventional UV/IR 2 Flame Detector (29600-203)
Note:
Meets EN 54-10: 2002 at Class 1 only
Conventional UV/IR 2 (Exd) Flameproof Flame Detector (29600-203)
Note:
Meets EN 54-10: 2002 at Class 1 only
Analogue Addressable IR 3 Intrinsically Safe Flame Detector (29600-203)
Note:
Meets EN 54-10: 2002 at Class 1 only
Analogue Addressable IR 3 Flame Detector (29600-203)
Note:
Meets EN 54-10:2002 at Class 1 only
Analogue Addressable IR 3 (Exd) Flameproof Flame Detector (29600-203)
Note:
Meets EN 54-10:2002 at Class 1 only
Analogue Addressable IR 2 Flame Detector (29600-203)
Note:
Meets EN 54-10:2002 at Class 1 only
Analogue Addressable IR 2 (Exd) Flameproof Flame Detector (29600-203)
LPCB Ref.
No.
010an/01
010an/02
010an/03
010an/04
010an/05
010an/06
010an/07
010an/08
010an/09
010an/10
010an/11
010an/12
010an/13
010an/14
010an/15
010an/16
237
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
Note:
Meets EN 54-10:2002 at Class 1 only
Bases
45681-200
45681-201
45681-209
45681-210
29600-203
Mounting Base
Mounting Base with Diode
Deep Base
Mounting Base
Adjustable Mounting Base
Ancillaries
29600-203 Mounting Bracket
Certificate No: 010aq to LPS 1274: 2005, EN 54-5: 2000 + A1: 2002 and LPS 1265: 2004
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
58000-305
LPCB Ref.
No.
010aq/01
Analogue addressable CO/heat multisensor detector
(45681-210, standard intelligent mounting base)
Notes:
1. Approved with the following mode configurations:Mode 1
30 ppm with high thermal enhancement (most sensitive)
Mode 2
33 ppm with CO only
Mode 3
40 ppm with low thermal enhancement (nominal sensitivity)
45 ppm with high thermal enhancement (least sensitive)
Mode 4
Mode 5
heat onlyA1R
2. Mode 1 , 3, and 4 are approved to LPS1274:2005 and EN 54-5:2000 + A1: 2002
3. Mode 2 is approved to LPS 1265:2004
4. Mode 5 is approved to EN 54-5:2000 + A1:2002
Conditions of approval include;
a)
b)
c)
Base:
45681-210
The 58000-305 should only be installed in accordance with the manufacturer’s
recommendations.
The 58000-305 should not be set only as a carbon monoxide fire detector
where there is a specific risk of rapid burning/flaming fires.
Refer to technical publication PP2382 for limitations on the use of carbon
monoxide fire detection.
Standard intelligent mounting base
Certificate No: 010at to EN 54-17: 2005
Isolating base
Certificated Products
45681-505
Negative switching isolating base
LPCB Ref.
No.
010at/01
Certificate No: 010ar to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
55000-465
55000-475
Analogue addressable Classheat detector
(45681-200 , 45681-213 and 45681-505 mounting bases)
Analogue addressable Classheat detector
(45681-200 , 45681-213 and 45681-505 mounting bases)
LPCB Ref.
No.
010ar/01
010ar/02
Bases:
238
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
45681-200 Mounting base
45681-213 Common mounting base
45681-505 Negative switching isolating base
Certificate No: 010as to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
55000-665
Analogue addressable optical smoke
(45681-200 , 45681-213 and 45681-505 mounting bases)
LPCB Ref.
No.
010as/01
Bases:
45681-200 Mounting base
45681-213 Common mounting base
45681-505 Negative switching isolating base
Argus Security S.r.l.
Via del Canneto 14, Valle delle Noghere, 34015 Muggia, Trieste, Italy
Tel: +39 (0) 402821110 • Fax: +39 (0) 402823483
E-mail: [email protected] • Website: www.argussecurity.it
Certificate No: 928a to EN 54-5: 2000 + A1: 2002 and EN 54 -17: 2005
Certificate No: 928d to EN 54-5: 2000 + A1: 2002
Point Heat Detectors
Certificated Products
V350
A3500
LV350
S3500
Bases
VB100
UB100
VB100S
UB100S
VDBS100
DBS100
VDBS100S
DBS100S
UBR100
DBSR100
UBDR100
DBSRD100
LAB100
Analogue addressable Class P heat detector with short circuit isolator (VB100, UB100,
VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B
Addressable Class P heat detector with short-circuit isolator (LAB100 base)
Note:
1. Meets the requirements of EN 54-5 for Class A1R, Class B and Class BS
Vega-Lite analogue addressable Class P, heat detector (VB100, UB100, VB100S,
UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B.
Conventional Class P heat detector (UB100, DBS100, UBR100, DBSR100, UBDR100
and DBSRD100)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B
LPCB Ref.
No.
928a/01
928a/02
928d/01
928d/02
Vega adaptor mounting base (with link resistor)
Universal adaptor mounting base
Vega adaptor base with shorting clip
Universal adaptor base with shorting clip
Vega deep adaptor base
Deep adaptor base
Vega deep adaptor base with shorting clip
Deep adaptor base with shorting clip
Universal adaptor base with resistor
Deep adaptor base with resistor
Universal adaptor base with resistor and Schottky diode
Deep adaptor base with resistor and Schottky diode
Standard mounting base
Certificate No: 928b to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Certificate No: 928e to EN 54-7: 2000 + A1: 2002 + A2: 2006
20 Oct 2014
239
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Point Smoke Detectors
Certificated Products
LPCB Ref.
No.
928b/01
V100
Analogue addressable photoelectric smoke detector with short circuit
isolator (VB100, UB100, VB100S, UB100S, VDBS100, DBS100,
VDBS100S and DBS100S bases)
Note:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
A1000
Addressable photoelectric smoke detector with short-circuit isolator (LAB100 base)
Notes:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
928b/02
LV100
Vega-Lite analogue addressable optical smoke detector (VB100,
UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and
DBS100S bases)
Note:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
928e/01
S1000
Conventional photo smoke detector (UB100, DBS100, UBR100, DBSR100, UBDR100
and DBSRD100)
928e/02
Bases
VB100
UB100
VB100S
UB100S
VDBS100
DBS100
VDBS100S
DBS100S
UBR100
DBSR100
UBDR100
DBSRD100
LAB100
Vega adaptor mounting base (with link resistor)
Universal adaptor mounting base
Vega adaptor base with shorting clip
Universal adaptor base with shorting clip
Vega deep adaptor base
Deep adaptor base
Vega deep adaptor base with shorting clip
Deep adaptor base with shorting clip
Universal adaptor base with resistor
Deep adaptor base with resistor
Universal adaptor base with resistor and Schottky diode
Deep adaptor base with resistor and Schottky diode
Standard mounting base
Certificate No: 928c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA 4021: 2003
Certificate No: 928f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Multisensor Detectors
Certificated Products
V200
240
Analogue addressable Class P heat and photoelectric smoke multi
sensor detector with short circuit isolator (VB100, UB100, VB100S,
UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases)
Notes
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:
Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with
Class A1 heat response
Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat
response
Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat
response
Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with
Class A1 heat response
2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
3. Meets the requirements of EN 54-7 at the following settings:
LPCB Ref.
No.
928c/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Addressable multi-criteria detector with short-circuit isolator (LAB100 base)
Notes:
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:
Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
Multi Criteria Level 2 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 3 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
3. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Vega-Lite analogue addressable photo thermal multisensor (VB100,
UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and
DBS100S bases)
Notes
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:
Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat
response
Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat
response
Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with
Class A1 heat response
2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
3. Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
A2000
LV200
Bases
VB100
UB100
VB100S
UB100S
VDBS100
DBS100
VDBS100S
DBS100S
LAB100
LPCB Ref.
No.
928c/02
928f/01
Vega adaptor mounting base (with link resistor)
Vega universal mounting base
Vega adaptor base with shorting clip
Universal adaptor base with shorting clip
Vega deep adaptor base
Deep adaptor base
Vega deep adaptor base with shorting clip
Deep adaptor base with shorting clip
Standard mounting base
Certificate No: 928j to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008
Heat Detectors
Certificated Products
SG350
20 Oct 2014
Wireless heat detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1R
2. The device must be used with the following batteries only:
CR123A (3 Vdc) - main battery
CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928j/01
241
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Bases
WAB100
Wireless Adaptor Base
Certificate No: 928k to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008
Smoke Detectors
Certificated Products
SG100
Bases
WAB100
Wireless optical smoke detector (WAB100 base)
Notes:
1.
Meets the requirements of EN 54-7 in the normal sensitivity setting
2.
The device must be used with the following batteries only:
CR123A (3 Vdc) - main battery
CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928k/01
Wireless Adaptor Base
Certificate No: 928m to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
SG200
Bases
WAB100
Wireless multi-criteria detector (WAB100 base)
Notes:
1.
Meets the requirements of EN 54-5 for Class A1
2.
Meets the requirements of EN 54-7 in the normal sensitivity settings
3.
The device must be used with the following batteries only:
CR123A (3 Vdc) - main battery
CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928m/01
Wireless Adaptor Base
Argus-Spectrum
65 Serdobolskaya St, St. Petersburg 197342, Russian Federation
Tel: +7 812 7037500 • Fax: +7 812 7037501
E-mail: [email protected] • Website: www.argus-spectr.ru
Certificate No: 928k-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008
Smoke Detectors
Certificated Products
SG100
Wireless optical smoke detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-7 in the normal sensitivity setting
2. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928k/01
Bases:
WAB100 - Wireless Adaptor Base
Certificate No: 928a-(cl-2) to 54-5: 2000 + A1: 2002 and EN 54 -17: 2005
Certificate No: 928d-(cl-2) to EN 54-5: 2000 + A1: 2002
Certificate No: 603d to EN 54-5: 2000 + A1: 2002
Certificate No: 928j-(cl-3) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008
242
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Point Heat Detectors
Certificated Products
S3500
Conventional Class P heat detector (UB100, DBS100, UBR100, DBSR100, UBDR100
and DBSRD100)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B
Analogue addressable Class P heat detector with short circuit isolator (VB100 and
UB100 bases)
Notes
1. Meets the requirements of EN 54-5 for Class A1R and Class B.
V350
LPCB Ref.
No.
603d/01
928a/01
LV350
Vega-Lite analogue addressable Class P, temperature detector (VB100 and UB100
bases)
Notes
1. Meets the requirements of EN 54-5 for Class A1R and Class B.
928d/01
SG350
Wireless heat detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1R
2. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery
 CR2032A (3 Vdc) - secondary battery
928j/01
Bases:
BS100
BSD100
VB100
UB100
DBS100
UBR100
DBSR100
UBDR100
DBSRD100
WAB100
Standard base
Schottky Diode base
Vega adaptor mounting base (with link resistor)
Universal adaptor base
Deep adaptor base
Universal adaptor base with resistor
Deep adaptor base with resistor
Universal adaptor base with resistor and Schottky diode
Deep adaptor base with resistor and Schottky diode
Wireless Adaptor Base
Certificate No: 928b-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005
Certificate No: 928e-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 603c to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detector
Certificated Products
S1000
Conventional photo smoke detector (UB100, DBS100, UBR100, DBSR100, UBDR100
and DBSRD100)
Analogue addressable photoelectric smoke detector with short circuit isolator (VB100 and
UB100 bases)
V100
Notes
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 Low
Vega-Lite analogue addressable optical smoke detector (VB100 and UB100 bases)
LV100
LPCB Ref.
No.
603c/01
928b/01
928e/01
Notes
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 Low
Bases
VB100
UB100
UB100
DBS100
UBR100
DBSR100
UBDR100
DBSRD100
Vega adaptor mounting base (with link resistor)
Vega universal mounting base
Universal adaptor base
Deep adaptor base
Universal adaptor base with resistor
Deep adaptor base with resistor
Universal adaptor base with resistor and Schottky diode
Deep adaptor base with resistor and Schottky diode
20 Oct 2014
243
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 928c-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA4021: 2003
Certificate No: 928f-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Multi-sensor Detectors
Certificated Products
V200
Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with
short circuit isolator (VB100 and UB100 bases)
Notes
1.
2.
3.
LV200
LPCB Ref.
No.
928c/01
Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following
settings:
Multi criteria level 1 (most sensitive) - thermally enhanced
smoke detection with Class A1 heat response
Multi criteria level 2 - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 3 - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 4 (least sensitive) - thermally enhanced
smoke detection with Class A1 heat response
Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Vega-Lite analogue addressable photo thermal multisensor (VB100 and UB100 bases)
Notes
1.
2.
3.
928f/01
Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following
settings:
Multi criteria level 1 (most sensitive) - thermally enhanced
smoke detection with Class A1 heat response
Multi criteria level 2 - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 3 - thermally enhanced smoke detection with
Class A1 heat response
Multi criteria level 4 (least sensitive) - thermally enhanced
smoke detection with Class A1 heat response
Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Bases
VB100 Vega adaptor mounting base (with link resistor)
UB100 Vega universal mounting base
Certificate No: 928m-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
SG200
Wireless multi-criteria detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1
2. Meets the requirements of EN 54-7 in the normal sensitivity setting
3. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928m/01
Bases:
WAB100 Wireless Adaptor Base
244
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
ATEIS Middle East FZCO
LIU 11 Dubai Silicon Oasis, Post Box 293640, Dubai, United Arab Emirates
Tel: +971 4 3262730 • Fax: +971 4 3262731
E-mail: [email protected] • Website: www.ateis.ae
Certificate No: 928a-(cl-7) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005
Certificate No: 1154a to EN 54-5: 2000 + A1: 2002 & EN 54-17:2005
Certificate No: 1154d to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
VELOX 40930
VELOX LV350
X350
VELOX V350
Bases
VELOX VB100
UB100
VELOX VB100S
UB100S
VELOX VDBS100
DBS100
VELOX VDBS100S
DBS100S
UBR100
DBSR100
UBDR100
DBSRD100
40900
40900-S
40900-DP
40900-DPS
3900
3900-DP
3900-R
3900-DPR
3900-RD
3900-DPRD
Analogue Addressable Class P Heat Detector with Short Circuit Isolator (40900, 40900S, 40900-DP and 40900-DPS Bases)Note:Meets the requirements of EN 54-5 for Class
A1R and Class B
Analogue addressable Class P heat detector lite (40900, 40900-S, 40900-DP, 40900DPS bases)
Note:
Meets the requirements of EN 54-5 for Class A1R and Class B
Conventional Class P heat detector (3900, 3900-DP, 3900-R, 3900-DPR, 3900-RD and
3900-DPRD bases)
Note:
Meets the requirements of EN 54-5 for Class A1R and Class B
Analogue addressable Class P heat detector with short circuit isolator (VELOX VB100,
UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and
DBS100S bases)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B
LPCB Ref.
No.
1154a/01
1154d/01
1154d/02
928a/01
Velox adaptor base
Universal adaptor base
Velox adaptor base with shorting clip
Universal adaptor base with shorting clip
Velox deep adaptor base
Deep adaptor base
Velox deep adaptor base with shorting clip
Deep adaptor base with shorting clip
Universal adaptor base with resistor
Deep adaptor base with resistor
Universal adaptor base with resistor and Schottky diode
Deep adaptor base with resistor and Schottky diode
Velox adaptor base
Velox adaptor base with short clip
Velox deep adaptor base
Velox deep adaptor base with short clip
Conventional detector adaptor base
Conventional detector deep adaptor base
Conventional detector adaptor base with resister
Conventional detector deep adaptor base with resistor
Conventional detector adaptor base with resistor and Schottky diode
Conventional detector deep adaptor base with resister and Schottky diode
Certificate No: 928b-(cl-7) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Certificate No: 928k-(cl-4) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008
Certificate No: 1154e to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 1154b to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005
Smoke Detectors
Certificated Products
VELOX 40910
20 Oct 2014
Analogue Addressable Photoelectric Smoke Detector with Short Circuit Isolator (40900,
40900-S, 40900-DP and 40900-DPS Bases)
Note:
Meets the requirements of EN 54-7 at the following sensitivity settings:
LPCB Ref.
No.
1154b/01
245
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Analogue addressable photoelectric smoke detector lite (40900, 40900-S, 40900-DP and
40900-DPS bases)
Note:
Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Conventional photoelectric smoke detector (3900, 3900-DP, 3900-R, 3900-DPR, 3900RD and 3900-DPRD bases)
Analogue addressable photoelectric smoke detector with short circuit isolator (VELOX
VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX
VDBS100S and DBS100S bases)
Note:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Wireless optical smoke detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1R
2. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
VELOX LV100
X100
VELOX V100
VELOX WL100
Bases
VELOX VB100
UB100
VELOX VB100S
UB100S
VELOX VDBS100
DBS100
VELOX VDBS100S
DBS100S
WAB100
40900
40900-S
40900-DP
40900-DPS
3900
3900-DP
3900-R
3900-DPR
3900-RD
3900-DPRD
LPCB Ref.
No.
1154e/01
1154e/02
928b/01
928k/01
Velox adaptor base
Universal adaptor base
Velox adaptor base with shorting clip
Universal adaptor base with shorting clip
Velox deep adaptor base
Deep adaptor base
Velox deep adaptor base with shorting clip
Deep adaptor base with shorting clip
Wireless Adaptor Base
Velox adaptor base
Velox adaptor base with short clip
Velox deep adaptor base
Velox deep adaptor base with short clip
Conventional detector adaptor base
Conventional detector deep adaptor base
Conventional detector adaptor base with resister
Conventional detector deep adaptor base with resistor
Conventional detector adaptor base with resistor and Schottky diode
Conventional detector deep adaptor base with resister and Schottky diode
Certificate No: 928c-(cl-7) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003
Certificate No: 928m-(cl-4) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003
Certificate No: 1154f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003
Certificate No: 1154c to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005 & CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
VELOX 40920
Analogue Addressable Class P Heat and Photoelectric Smoke Multi-sensor Detector with
Short Circuit Isolator (40900, 40900-S, 40900-DP and 40900-DPS Bases)
LPCB Ref.
No.
1154c/01
Notes:
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:
Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with
Class A1 heat response
Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat
response
Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat
246
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
VELOX LV200
VELOX V200
VELOX WL200
LPCB Ref.
No.
response
Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with
Class A1 heat response
2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R
heat only response
3. Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Analogue addressable Class P heat and photoelectric smoke multi-sensor detector lite
(40900, 40900-S, 40900-DP and 40900-DPS bases)
Notes:
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:
Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with
Class A1 heat response
Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1
heat response
Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1
heat response
Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection
with Class A1 heat response
2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R
heat only response
3. Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with
short circuit isolator (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX
VDBS100, DBS100, VELOX VDBS100S and DBS100S bases)
Notes:
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:
Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
Multi Criteria Level 2 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 3 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
3. Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Wireless multi-criteria detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1
2. Meets the requirements of EN 54-7 in the normal sensitivity setting
3. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
Bases
VELOX VB100
UB100
VELOX VB100S
UB100S
VELOX VDBS100
DBS100
VELOX VDBS100S
DBS100S
WAB100
Velox adaptor base
Universal adaptor base
Velox adaptor base with shorting clip
Universal adaptor base with shorting clip
Velox deep adaptor base
Deep adaptor base
Velox deep adaptor base with shorting clip
Deep adaptor base with shorting clip
Wireless Adaptor Base
40900
40900-S
40900-DP
40900-DPS
Velox adaptor base
Velox adaptor base with short clip
Velox deep adaptor base
Velox deep adaptor base with short clip
20 Oct 2014
1154f/01
928c/01
928m/01
247
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 928j-(cl-4) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008
Point Heat Detectors
Certificated Products
VELOX WL350
Bases:
WAB100
Wireless heat detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1R
2. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928j/01
Wireless Adaptor Base
Autronica Fire & Security AS
Postboks 5620 NO-7483, Trondheim, Norway
Tel: +47 73582500 • Fax: +47 73582501
E-mail: [email protected] • Website: www.autronicafire.no
Certificate No: 1130a to EN54-10: 2002 + A1: 2005 & EN54-17: 2005
Certificate No: 1130b to EN54-10: 2002 + A1: 2005
Flame Detectors
Certificated Products
BG-201
BG-21
Anaologue addressable IR flame detector (interactive)
Note: Meets EN54-10: 2002 at Class 1, Class 2 & Class 3
Conventional IR flame detector
Note: Meets EN54-10: 2002 at Class 1 & Class 3
LPCB Ref.
No.
1130a/01
1130b/01
Bardic by Honeywell (Novar Systems Ltd)
140 Waterside Road, Hamilton Industrial Estate, Leicester LE5 1TN, United Kingdom
Tel: +44 (0) 116 246 2212 • Fax: +44 (0) 116 246 2210
Website: www.bardic.co.uk
Certificate No: 199n to EN 54-5: 2000
Heat Detectors
Certificated Products
ZF03 class A2S
ZF04 class BS
ZF05 class A1R
Conventional fixed temperature heat detector
(2020B, 2020DB, 2020BSD, 2020DBSD bases)
Conventional fixed temperature heat detector
(2020B, 2020DB, 2020BSD, 2020DBSD bases)
Conventional rate of rise heat detector
(2020B, 2020DB, 2020BSD, 2020DBSD bases)
LPCB Ref.
No.
199n/10
199n/11
199n/12
Bases:
2020B Standard base
2020DB Deep base
2020BSD Standard base with schottky diode
2020DBSD Deep base with schottky diode
Certificate No: 199m to EN 54-7: 2000
248
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Photoelectric Detectors
Certificated Products
ZF01
Conventional photoelectric detector
(2020B, 2020DB, 2020BSD, 2020DBSD bases)
LPCB Ref.
No.
199m/05
Bases:
2020B Standard base
2020DB Deep base
2020BSD Standard base with schottky diode
2020DBSD Deep base with schottky diode
Certificate No: 199p to EN 54-5: 2000, EN 54-7: 2000 & CEA 4021 1999
Multi-criteria Detectors
Certificated Products
ZF02
Conventional photo thermal detector
(2020B, 2020DB, 2020BSD, 2020DBSD bases)
LPCB Ref.
No.
199p/04
Bases:
2020B Standard base
2020DB Deep base
2020BSD Standard base with schottky diode
2020DBSD Deep base with schottky diode
Beijing Leader Huaxin Electronics Co. Ltd
No. 17 Rongjing Eastern Road, Economy & Technology Developed Area, Beijing 100176, China
Tel: +86 10 67876681 • Fax: +86 10 67863972
E-mail: [email protected] • Website: www.beijingleader.com.cn
Certificate No: 987a to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificated Products
JTY-GM-LD3000EN/A
Analogue addressable photoelectric smoke detector
(LD10EN base)
LPCB Ref.
No.
987a/01
Bases:
LD10EN mounting base
Beijing VSAIL Fire Protection Equipment Co Ltd
No. 401, Unit A, Building 32,, No. 99 14th Kechuang Street, BDA, Beijing 100176, China
Tel: +86 (0) 10-56691196 • Fax: +86 (0) 10-56691100
Website: http://www.vsail.com.cn
Certificate No: 1174b to EN 54-5:2000 + A1: 2002
Heat detector
Certificated Products
VC-6633
Conventional heat detector
Note: Meets the requirements of EN 54-5 2000 at class A2R
LPCB Ref.
No.
1174b/01
Base
VB-6611
Certificate No: 1174a to EN54:7:2000 + A1: 2002 + A2: 2006
20 Oct 2014
249
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Smoke Detectors
Certificated Products
VC-6623
LPCB Ref.
No.
1174a/01
Conventional Optical Smoke Detector (VB-6611 base)
Note:
Meets the requirements of EN 54-7: 2000 at default sensitivity setting only.
Base
VB-6611
Bristol Fire Ltd
The Colin Saunders Innovation Centre, Mewburn Road, Banbury, Oxfordshire OX16 9PA, United Kingdom
Tel: +44 1295 817623
E-mail: [email protected] • Website: www.bristol-fire.com
Certificate No: 506b-(cl-2) to EN 54-7 : 2000 + A1: 2002 + A2: 2006, EN 54-5 : 2000 + A1 : 2002 and CEA 4021: 2003
Point Smoke Detectors
Certificated Products
BF-SH-0115-2
BF-SH-0115-3
BF-SH-0115-4
(2 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base)
(3 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base)
(4 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base)
LPCB Ref.
No.
506b/01
506b/02
506b/03
Bases
AHMB-031 mounting base
Certificate No: 506c-(cl-2) to EN 54-5: 2000 + A1 : 2002
Heat Detectors
Certificated Products
BF-H-0116-2
BF-H-0116-3
BF-H-0116-4
(2 Wire) Conventional Class A2 rate of rise and fixed temperature Heat detector
(AHMB-031 Base)
(3 Wire) Conventional Class A2 rate of rise and fixed temperature Heat detector
(AHMB-031 Base)
(4 Wire) Conventional Class A2 rate of rise and fixed temperature Heat detector
(AHMB-031 Base)
LPCB Ref.
No.
506c/01
506c/02
506c/03
Bases
AHMB-031 mounting base
Certificate No: 506a-(cl-3) to EN 54-7 : 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
BF-S-0111-2
BF-S-0111-3
BF-S-0111-4
(2 wire) Conventional Photoelectric smoke detector (AHMB-031-L Base)
(3 wire) Conventional Photoelectric smoke detector (AHMB-031-L Base)
(4 wire) Conventional Photoelectric smoke detector (AHMB-031-L Base)
LPCB Ref.
No.
506a/02
506a/03
506a/04
Bases
AHMB-L Mounting base
AHMB-031 Mounting base
250
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Ceasefire Industries Ltd
"Doli Chambers", Flat 602 6th Floor behind strand cinema, Colaba, Mumbai-400 005, India
Tel: + 91-(0) 22-22854677 • Fax: +91-(0) 22-66349069
E-mail: [email protected] • Website: www.ceasefire.in
Certificate No: 117g-(cl-1) to EN54-5:2000
Point Heat Detectors
Certificated Products
DFJ-AE3
Class A1S conventional fixed temperature heat detector
(YBN-R/6 base)
Class CR conventional rate of rise high temperature heat detector
(YBN-R/6 base)
Analogue addressable Class P heat detector
(YBN-R/3 and YBO-R/SCI bases)
Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when
used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol.
DCD-CE3
ACB-E
LPCB Ref.
No.
117g/02
117g/06
117g/09
Bases
YBN-R/3 base
YBN-R/6 standard base
YBO-R/SCI isolator base
Certificate No: 358c-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
ALK-E (WHT)
Analogue addressable optical smoke detector (White)
(YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)
Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in
normal and low power modes
Conventional optical smoke detector (White)
(YBN-R/6)
SLV-E3 (WHT)
Bases
YBN-R/3
YBN-R/6
YBO-R/SCI
YBO-BS
YBO-BSB
LPCB Ref.
No.
358c/03
358c/05
base
standard base
isolator base
base sounder
base sounder and beacon
Chubb Fire Ltd
Chubb House, Staines Road West, Sunbury on Thames TW16 7AR, United Kingdom
Tel: +44 (0)1932 785588 • Fax: +44 (0)1932 777222
E-mail: [email protected] • Website: www.chubb.co.uk
Certificate No: 118h to EN 54-7: 2000
Point Smoke Detectors
Certificated Products
Resonance High Sensitivity
Laser
Analogue addressable photoelectric laser smoke detector (B501, B501DG and
B5241EFT & B524IEFT-1 bases)
Note: meets the requirements of EN 54-7: 2000 at sensitivities 7 to 9 inclusive
LPCB Ref.
No.
118h/01
Bases:
B501 Analogue sensor base
B501DG Analogue sensor deep base
B524IEFT Analogue sensor isolator base
20 Oct 2014
251
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Consilium Marine and Safety AB
Salsmästaregatan 21 Box 8763, Gothenburg SE402 76, Sweden
Tel: +46 31 710 77 64 • Fax: +46 31 710 78 00
E-mail: [email protected] • Website: www.consilium.se
Certificate No: 041k-(cl-1) to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003
Photoelectric smoke and heat detectors
Certificated Products
EV-PP
Analogue addressable combined photoelectric smoke and class A1 heat sensor
LPCB Ref.
No.
041k/01
Bases
UB-2 Universal base
UB-6 Universal base
Context Plus Ltd
Export House, 175 Mauldeth Road, Fallowfield, Manchester M14 6SG, United Kingdom
Tel: +44 (0)161 257 2541 • Fax: +44 (0)161 225 8817
E-mail: [email protected] • Website: www.xportsales.com
Certificate No: 010u-(cl-2) to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
55000-465IMC
Analogue addressable Class A2S heat detector
45681-213IMC and 45681-505IMC bases)
Analogue addressable Class CS heat detector
45681-213IMC and 45681-505IMC bases)
55000-475IMC
Bases
45681-200IMC
45681-213IMC
45681-505IMC
LPCB Ref.
No.
010u/04
010u/05
Mounting base
Common mounting base
Negative switching isolating base
Certificate No: 010v-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
55000-665IMC
Bases
45681-200IMC
45681-213IMC
45681-505IMC
252
Analogue addressable optical smoke
45681-213IMC and 45681-505IMC bases)
LPCB Ref.
No.
010v/02
Mounting base
Common mounting base
Negative switching isolating base
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Control Equipment Limited
Hillcrest Business Park, Dudley, West Midlands DY2 9AP, United Kingdom
Tel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972
E-mail: [email protected] • Website: www.controlequipment.com
Certificate No: 681b-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA4021: 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
FC460PC
FC460PH
FIRE CLASS digital addressable photoelectric smoke, Class P heat and Carbon
Monoxide detector (4B, 4B-I, and 5B bases)
Notes:
1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector
-RESIL Resilient optical smoke and A2S heat multi-criteria detector
- Heat detector at Class A1R
- HPO Heat enhanced optical smoke detector at Normal sensitivity
2. The Carbon Monoxide toxic gas/CCO modes are not approved
FIRE CLASS digital addressable photoelectric smoke and Class P heat detector (4B, 4BI, and 5B bases)
Note:
Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity
- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using
FastLogic.
LPCB Ref.
No.
681b/03
681b/05
Bases
4B, 4” universal mounting base
4B-I, 4” isolator base
5B, 5” universal mounting base
Certificate No: 681c-(cl-2) to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
FC460H
FIRE CLASS digital addressable Class P heat detector (4B, 4B-I and 5B bases)
Note:
Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- Heat detector at Class CR
LPCB Ref.
No.
681c/10
Bases
4B, 4” universal mounting base
4B-I, 4” isolator base
5B, 5” universal mounting base
Certificate No: 681d-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
FC460P
20 Oct 2014
FIRE CLASS digital addressable photoelectric smoke detector
(4B, 4B-I and 5B bases)
Note:
1. Approved with the following mode configurations:-
LPCB Ref.
No.
681d/07
253
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
Bases
4B, 4” universal mounting base
4B-I, 4” isolator base
5B, 5” universal mounting base
Cooper Safety
Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom
Tel: +44 (0)1302 321541 • Fax: +44 (0)1302 303220
Certificate No: 685j-(cl-1) to EN 54-7:2000 + A1:2002 + A2:2006 & EN 54-17:2005
Certificate No: 685j-(cl-2) to EN 54-7:2000 + A1:2002 + A2:2006 & EN 54-17:2005
Certificate No: 685h-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 685h-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
CPD321
CPDB321
FXN533
MPD821
CAP320
CAPB320
COPP420
FXN723
MAP820
Bases
MDB800
MCBD
FXCBD
NDFXN520
FXN520
CDB300
CDBB300
CCBD
MAB800
CABB300
FXN720
MABD
CABD
FXABD
CAB300
COPA800
254
Conventional photoelectric smoke detector CDBB300, MCBD, CCBD and NDFXN520
bases)
Conventional photoelectric smoke detector FXCBD, CCBD and NDFXN520 bases)
Conventional photoelectric smoke detector FXCBD and NDFXN520 bases)
Conventional photoelectric smoke detector MCBD and NDFXN520 bases)
Intelligent analogue addressable photoelectric smoke detector
MABD, FXABD and CABD bases)
Intelligent analogue addressable photoelectric smoke detector
MABD, FXABD and CABD bases)
Intelligent analogue addressable photoelectric smoke detector
MABD, FXABD and CABD bases)
Intelligent analogue addressable photoelectric smoke detector
MABD, FXABD and CABD bases)
Intelligent analogue addressable photoelectric smoke detector
MABD, FXABD and CABD bases)
LPCB Ref.
No.
685h/01
685h/01
685h/01
685h/01
685j/01
685j/01
685j/01
685j/01
685j/01
Single contact standard conventional mounting base (Zener diode)
Double contact standard conventional mounting base (Zener diode)
Double contact conventional mounting base (Schottky diode)
Single contact conventional mounting base (without diode)
Single contact conventional mounting base (Schottky diode)
Single contact standard conventional mounting base (Zener diode)
Single contact conventional mounting base (Schottky diode)
Double contact conventional mounting base (Schottky diode)
Single contact standard analogue addressable mounting base
Single contact standard analogue addressable mounting base
Single contact standard analogue addressable mounting base
Double contact standard analogue addressable mounting base
Double contact standard analogue addressable mounting base
Double contact standard analogue addressable mounting base
Single contact standard analogue addressable mounting base
Single contact standard analogue addressable mounting base
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 685k-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA4021: July
2003(en)
Certificate No: 685k-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA4021: July
2003(en)
Certificate No: 685g-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Certificate No: 685g-(cl-2) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Multi-criteria Detectors
Certificated Products
CPT341
CPTB341
FXN632
MPT951
CXN633
FXN922
MPT922
CAPT340
CAPTB340
20 Oct 2014
Conventional photo/thermal multisensor and Class A2S heat detector CDBB300. MCBD,
CCBD and NDFXN520 bases)
Conventional photo/thermal multisensor and Class A2S heat detector CCBD and
NDFXN520 bases)
Conventional photo/thermal multisensor and Class A2S heat detector (FXN520, FXCBD
and NDFXN520 bases)
Conventional photo/thermal multisensor and Class A2S heat detector MCBD and
NDFXN520 bases)
Conventional photo/thermal multisensor and Class P heat detector CDBB300, FXCBD
and CCBD bases)
Notes:
1. Meets the requirements of EN 54-7:2000
in the following modes:
Mode 1 - Thermally enhanced optical smoke detector
Smoke sensitivity 0.15dB/m.
Mode 2 - Optical smoke detector.
Smoke sensitivity 0.1dB/m.
2. Meets the requirements of EN 54-5:2000
in the following modes:
Mode 3 - Heat detector Class A1R
Mode 4 - Heat detector Class BS
Mode 5 - Heat detector Class CS
Conventional photo/thermal multisensor and Class P heat detector CDBB300, FXCBD,
CCBD)
Notes:
1. Meets the requirements of EN 54-7:2000
in the following modes:
Mode 1 - Thermally enhanced optical smoke detector
Smoke sensitivity 0.15dB/m.
Mode 2 - Optical smoke detector.
Smoke sensitivity 0.1dB/m.
2. Meets the requirements of EN 54-5:2000
in the following modes:
Mode 3 - Heat detector Class A1R
Mode 4 - Heat detector Class BS
Mode 5 - Heat detector Class CS
LPCB Ref.
No.
685g/01
685g/01
685g/01
685g/01
685g/02
685g/02
Conventional photo/thermal multisensor and Class P heat detector FXCBD, CCBD)
Notes:
1. Meets the requirements of EN 54-7:2000
in the following modes:
Mode 1 - Thermally enhanced optical smoke detector
Smoke sensitivity 0.15dB/m.
Mode 2 - Optical smoke detector.
Smoke sensitivity 0.1dB/m.
2. Meets the requirements of EN 54-5:2000
in the following modes:
Mode 3 - Heat detector Class A1R
Mode 4 - Heat detector Class BS
Mode 5 - Heat detector Class CS
Intelligent analogue addressable Class A2S multisensor
opto/heat detector MABD, FXABD and CABD bases)
Notes:
1) Meets the requirements of EN 54-5 and EN 54-7
in the following modes:
Mode 1 - Photoelectric/heat combined only
Mode 2 - Photoelectric/heat combined together with
an alarm output from temperature alone (Class A2S)
Mode 3 - Heat detector alone (Class A2S)
685g/02
Intelligent analogue addressable Class A2S multisensor
opto/heat detector MABD, FXABD and CABD bases)
685k/01
685k/01
255
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
Notes:
1) Meets the requirements of EN 54-5 and EN 54-7
in the following modes:
Mode 1 - Photoelectric/heat combined only
Mode 2 - Photoelectric/heat combined together with
an alarm output from temperature alone (Class A2S)
Mode 3 - Heat detector alone (Class A2S)
COPOH450
Intelligent analogue addressable Class A2S multisensor
opto/heat detector MABD, FXABD and CABD bases)
Notes:
1) Meets the requirements of EN 54-5 and EN 54-7
in the following modes:
Mode 1 - Photoelectric/heat combined only
Mode 2 - Photoelectric/heat combined together with
an alarm output from temperature alone (Class A2S)
Mode 3 - Heat detector alone (Class A2S)
685k/01
FXN722
Intelligent analogue addressable Class A2S multisensor
opto/heat detector MABD, FXABD and CABD bases)
Notes:
1) Meets the requirements of EN 54-5 and EN 54-7
in the following modes:
Mode 1 - Photoelectric/heat combined only
Mode 2 - Photoelectric/heat combined together with
an alarm output from temperature alone (Class A2S)
Mode 3 - Heat detector alone (Class A2S)
685k/01
MAOH850
Intelligent analogue addressable Class A2S multisensor
opto/heat detector MABD, FXABD and CABD bases)
Notes:
1) Meets the requirements of EN 54-5 and EN 54-7
in the following modes:
Mode 1 - Photoelectric/heat combined only
Mode 2 - Photoelectric/heat combined together with
an alarm output from temperature alone (Class A2S)
Mode 3 - Heat detector alone (Class A2S)
685k/01
Bases
MDB800
MCBD
NDFXN520
FXN520
FXCBD
CDBB300
CCBD
CDB300
MAB800
CABB300
FXN720
MABD
CABD
FXABD
CAB300
COPA800
CABD
Single contact standard conventional mounting base (Zener diode)
Double contact standard conventional mounting base (Zener diode)
Single contact conventional mounting base (without diode)
Single contact conventional mounting base (Schottky diode)
Double contact conventional mounting base (Schottky diode)
Single contact conventional mounting base (Schottky diode)
Double contact conventional mounting base (Schottky diode)
Single contact standard conventional mounting base (Zener diode)
Single contact standard analogue addressable mounting base
Single contact standard analogue addressable mounting base
Single contact standard analogue addressable mounting base
Double contact standard analogue addressable mounting base
Double contact standard analogue addressable mounting base
Double contact standard analogue addressable mounting base
Single contact standard analogue addressable mounting base
Single contact standard analogue addressable mounting base
Double contact standard analogue addressable mounting base
Certificate No: 685m-(cl-1) to EN 54-5: 2000+A1:2002 & EN 54-17: 2005
Certificate No: 685m-(cl-2) to EN 54-5: 2000+A1:2002 & EN 54-17: 2005
Heat Detectors
Certificated Products
CAH330
CAHB330
256
Intelligent analogue addressable Class P heat detector
MABD, FXABD and CABD bases)
Notes:
1)
Meets the requirements of EN 54-5 at classes A1R, BS and CS
Intelligent analogue addressable Class P heat detector
MABD, FXABD and CABD bases)
LPCB Ref.
No.
685m/01
685m/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
Notes:
1)
Meets the requirements of EN 54-5 at classes A1R, BS and CS
Intelligent analogue addressable Class P heat detector
MABD, FXABD and CABD bases)
Notes:
1)
Meets the requirements of EN 54-5 at classes A1R, BS and CS
Intelligent analogue addressable Class P heat detector
MABD, FXABD and CABD bases)
Notes:
1)
Meets the requirements of EN 54-5 at classes A1R, BS and CS
Intelligent analogue addressable Class P heat detector
MABD, FXABD and CABD bases)
Notes:
1)
Meets the requirements of EN 54-5 at classes A1R, BS and CS
COPH430
FXN725
MAH830
Bases
MAB800
CABB300
FXN720
CAB300
COPA800
MABD
FXABD
CABD
CABB300
LPCB Ref.
No.
685m/01
685m/01
685m/01
Standard analogue addressable mounting base
Standard analogue addressable mounting base
Standard analogue addressable mounting base
Standard analogue addressable mounting base
Standard analogue addressable mounting base
Double contact standard analogue addressable mounting base
Double contact standard analogue addressable mounting base
Double contact standard analogue addressable mounting base
Single contact standard analogue addressable mounting base
Certificate No: 685a-(cl-1) to EN 54-5: 2000 + A1: 2002
Certificate No: 685a-(cl-2) to EN 54-5: 2000 + A1: 2002
Point Heat Detectors
Certificated Products
CFR330
CFRB330
FXN525
MFR830
CMT360
CMTB360
FXN524
MMT860
CHT390
CHTB390
FXN526
MHT890
Bases
MDB800
MCBD
NDFXN520
FXN520
FXCBD
CDB300
CDBB300
CCBD
Conventional Class A2R heat detector CDBB300. MCBD, CCBD and NDFXN520 bases)
Conventional Class A2R heat detector CCBD and NDFXN520 bases)
Conventional Class A2R heat detector FXCBD and NDFXN520 bases)
Conventional Class A2R heat detector MCBD and NDFXN520 bases)
Conventional Class BS heat detector CDBB300, MCBD, CCBD, NDFXN520 bases)
Conventional Class BS heat detector CCBD and NDFXN520 bases)
Conventional Class BS heat detector FXCBD, NDFXN520 bases)
Conventional Class BS heat detector MCBD and NDFXN520 bases)
Conventional Class CS heat detector CDBB300, MCBD, CCBD and NDFXN520 bases)
Conventional Class CS heat detector CCBD, NDFXN520 bases)
Conventional Class CS heat detector FXCBD, NDFXN520 bases)
Conventional Class CS heat detector MCBD and NDFXN520 bases)
LPCB Ref.
No.
685a/01
685a/01
685a/01
685a/01
685a/02
685a/02
685a/02
685a/02
685a/03
685a/03
685a/03
685a/03
Single contact standard conventional mounting base (Zener diode)
Double contact standard conventional mounting base (Zener diode)
Single contact conventional mounting base (without diode)
Single contact conventional mounting base (Schottky diode)
Double contact conventional mounting base (Schottky diode)
Single contact standard conventional mounting base (Zener diode)
Single contact conventional mounting base (Schottky diode)
Double contact conventional mounting base (Schottky diode)
Cooper Sécurité SAS
Parc Européen d’Entreprises II, Rue Beethoven, BP 10184, 63204 Riom Cedex, France
Tel: +44 (0)1302 3397 • Fax: +44 (0)1302 303220
E-mail: [email protected]
Certificate No: 685j-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Certificate No: 685h-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006
20 Oct 2014
257
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Point Smoke Detectors
Certificated Products
DOFS3000
DOFA3000
Bases
NUG30256
NUG30255
NUG30257
NUG30258
Conventional photoelectric smoke detector and NUG30257 bases)
Intelligent analogue addressable photoelectric smoke detector
and NUG30258 bases)
LPCB Ref.
No.
685h/01
685j/01
Standard analogue addressable mounting base
Standard conventional mounting base
Double contact standard conventional mounting base
Double contact standard analogue addressable mounting base
Certificate No: 685m-(cl-3) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005
Heat Detectors
Certificated Products
DTVA3000
Bases
NUG30256
NUG30258
Intelligent analogue addressable Class P heat detector and NUG30258 bases)
Notes:
1. Meets the requirements of EN 54-5 at classes A1R, BS and CS
LPCB Ref.
No.
685m/01
Single contact standard analogue addressable mounting base
Double contact standard analogue addressable mounting base
Certificate No: 685k-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 , EN 54-17: 2005 and CEA4021: July
2003(en)
Certificate No: 685g-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
DMCFS3000
Conventional photo/thermal multisensor and Class A2S heat detector and NUG30257
bases)
Intelligent analogue addressable Class A2S multisensor opto/heat detector and
NUG30258 bases)
Notes:
1. Meets the requirements of EN 54-5 and EN 54-7in the following modes:
Mode 1 - Photoelectric/heat combined only
Mode 2 - Photoelectric/heat combined together with
an alarm output from temperature alone (Class A2S)
Mode 3 - Heat detector alone (Class A2S)
DMCFA3000
Bases
NUG30255
NUG30256
NUG30257
NUG30258
LPCB Ref.
No.
685g/01
685k/01
Standard conventional mounting base
Standard analogue addressable mounting base
Double contact standard conventional mounting base
Double contact standard analogue addressable mounting base
Certificate No: 685a-(cl-3) to EN 54-5: 2000 + A1: 2002
Point Heat Detectors
Certificated Products
DTVS3000
DTS77°S3000
DTS90°S3000
Conventional Class A2R heat detector and NUG30257 bases)
Conventional Class BS heat detector and NUG30257 bases)
Conventional Class CS heat detector and NUG30257 bases)
LPCB Ref.
No.
685a/01
685a/02
685a/03
Bases
NUG30255
Single contact standard conventional mounting base
NUG30257 Double contact standard conventional mounting base
258
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Detector Electronics Corporation
6901 West 110th Street, Minneapolis, Minesota 55438, USA
Tel: +001 952 946 6488
E-mail: [email protected] • Website: www.det-tronics.com
Certificate No: 973a to EN 54-10: 2002 + A1: 2005 and EN 54-17: 2005
Certificate No: 973e to EN 54-10: 2002 + A1: 2005
Certificated Products
X9800
Addressable Class 1 IR flame detector with short circuit isolator
Note : The isolation is applied on the LON communication transmission path and not the
power transmission path. Refer to the manufacturers installation document 95-8642 with
respect to the number of devices to be connected in a group or zone.
Addressable Class 1 UV / IR flame detector with short circuit isolator
Note : The isolation is applied on the LON communication transmission path and not the
power transmission path. Refer to the manufacturers installation document 95-8642 with
respect to the number of devices to be connected in a group or zone.
Addressable Class 1 multispectrum IR flame detector with short circuit isolator
Note: The isolation is applied on the LON communication transmission path and not the
power transmission path. Refer to the manufacturers installation document 95-8642 with
respect to the number of devices to be connected in a group or zone.
Addressable Class 1 UV flame detector with short circuit isolator
Note: The isolation is applied on the LON communication transmission path and not the
power transmission path. Refer to the manufacturers installation document 95-8642 with
respect to the number of devices to be connected in a group or zone.
Conventional Class 1 IR flame detector
Conventional Class 1 UV / IR flame detector
Conventional Class 1 multispectrum IR flame detector
Conventional Class 1 UV flame detector
X5200
X3301
X2200
X9800
X5200
X3301
X2200
LPCB Ref.
No.
973a/01
973a/02
973a/03
973a/04
973e/01
973e/02
973e/03
973e/04
EDS Elektronik Destek San. ve Tic. Ltd. Şti.
Meclis Mah. Teraziciller Cad., Kilic Sok., No. 4, Istanbul, 34785 Sangazi, Turkey
Tel: +44 (216) 5284500 • Fax: +44 (216) 3141780
Certificate No: 1086a to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
EC-P2L
EC-P2L-3
Base:
EC-DB
EC-DB3
Conventional optical smoke detector 5 pin
(EC-DB base)
Conventional optical smoke detector 3 pin
(EC-DB3 base)
LPCB Ref.
No.
1086a/01
1086a/02
5 pin base
3 pin base
Emergi-Lite Safety Systems (Thomas & Betts Ltd)
Bruntcliffe Lane, Morley, Leeds LS27 9LL, United Kingdom
Tel: +44 (0)113 2810600 • Fax: +44 (0)113 2810601
Website: www.emergi-lite.co.uk
Certificate No: 010p to EN 54-5:2000 + A1:2002
20 Oct 2014
259
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Point Heat Detectors
Certificated Products
FADY-TEM
FAP6-RR6
FAP6-RR75
FAP6-RR90
FAP6-FT8
Analogue addressable heat detector (FA95-ACB mounting base)
Notes:
1) Meets the requirements of EN54: Part 5 Class A1R in mode 1 and in conventional mode
Class A2 in mode 2 and in conventional mode
Class A2S in mode 3 and in conventional mode
Class CR in mode 4 and in conventional mode
Class CS in mode 5 and in conventional mode
2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols
configured for the Discovery heat detector in accordance with manufacturers instructions.
Conventional Class A1R heat detector (FAP6-STB mounting base)
Notes:
1) Meets the requirements of EN54: Part 5 - Class A1R
Conventional Class BR heat detector (FAP6-STB mounting base)
Notes:
1) Meets the requirements of EN54: Part 5 - Class BR
Conventional Class CR heat detector (FAP6-STB mounting base)
Notes:
1) Meets the requirements of EN54: Part 5 - Class CR
Conventional Class CS heat detector (FAP6-STB mounting base)
Notes:
1) Meets the requirements of EN54: Part 5 - Class CS
LPCB Ref.
No.
010p/03
010p/06
010p/09
010p/12
010p/15
Bases:
FAP6-STB Mounting base
Certificate No: 010q to EN 54 - 7:2000 + A1:2002
Point Smoke Detectors
Certificated Products
FADY-OPT
FAP6-ION
FAP6-OPT
Analogue addressable optical smoke detector (FA95-ACB mounting base)
Notes:
1) Meets the requirements of EN54: Part 7 in modes 1, 2, 3, 4 and 5 and in conventional
mode.
2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols
configured for the Discovery heat detector in accordance with manufacturers instructions.
Conventional ionisation smoke detector (FAP6-STB mounting base)
Conventional optical smoke detector (FAP6-STB mounting base)
LPCB Ref.
No.
010q/03
010q/06
010q/12
Bases;
FAP6-STB Mounting base
Certificate No: 010h to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002, CEA 4021:2003
Multi-criteria Detectors
Certificated Products
FADY-MUS
Analogue addressable multisensor detector (FA95-ACB mounting base)
Notes:
1) Certificated at the following settings:
Mode 1 - High sensitivity smoke detector with standard heat enhancement
Mode 2 - Smoke detection only
Mode 3 - Medium sensitivity smoke detector with standard heat enhancement
Mode 4 - Low sensitivity smoke detector with high heat enhancement
Mode 5 - Class A1 heat detector
Also approved in conventional alarm modes 1, 2, 3, 4 and 5
2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols
configured for the Discovery heat detector in accordance with manufacturers instructions.
LPCB Ref.
No.
010h/01
Bases:
FA95-ACB Mounting base
FAP6-STB Diode mounting base
260
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Emirates Fire Fighting Equipment Factory L.L.C. (FIREX)
P.O.Box 22436, Industrial Area 13, Sharjah, United Arab Emirates
Tel: +971 6 5340300 • Fax: +971 6 5340090
E-mail: [email protected] • Website: www.firexuae.com
Certificate No: 506a to EN 54-7: 2000
Point Smoke Detectors
Certificated Products
FX-0311-2
FX-0311-3
FX-0311-4
(2 - wire) Conventional photoelectric smoke detector (AHMB-031 Base)
(3 - wire) Conventional photoelectric smoke detector (AHMB-031 Base)
(4 - wire) Conventional photoelectric smoke detector (AHMB-031 Base)
LPCB Ref.
No.
506a/02
506a/03
506a/04
Bases:
AHMB-031 mounting base
Certificate No: 506b to EN 43-7: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002 and CEA 4021: 2003
Multi-criteria Detectors
Certificated Products
FX-0315-2
FX-0315-3
FX-0315-4
(2 - wire) Optical smoke and Class A2 heat detector (AHMB-31 Base)
(3 - wire) Optical smoke and Class A2 detector (AHMB-31 Base)
(4 - wire) Optical smoke and Class A2 heat detector (AHMB-31 Base)
LPCB Ref.
No.
506b/01
506b/02
506b/03
Bases:
AHMB-031 mounting base
Certificate No: 506c to EN54-5: 2000
Point Heat Detector
Certificated Products
FX-0316-2
FX-0316-3
FX-0316-4
(2 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB31 Base)
(3 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB031 Base)
(4 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB31 Base)
LPCB Ref.
No.
506c/01
506c/02
506c/03
Bases:
AHMB-031 mounting base
Emirates Fire Protections Equip. Factory. TR. Section
Behind the Fourth Industrial Estate, Industrial Area 3, UAE PO 22436, Sharjah, United Arab Emirates
Tel: 00971 653 40300 • Fax: 00971 653 40090
E-mail: [email protected] • Website: www.firexuae.com
Certificate No: 548c-(cl-3) to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
FX9103
FX9103I
Conventional heat detector
Class A1R (DZ-03 base)
Intelligent Rate of Rise Heat Detector
Class A1R (DZ-03 base)
LPCB Ref.
No.
548c/01
548c/02
Bases:
20 Oct 2014
261
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
DZ-03 Standard detector base
Certificate No: 548d-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
FX9102
FX9102I
LPCB Ref.
No.
548d/01
Conventional Photoelectric Smoke Detector
(DZ-03 base)
Intelligent Photoelectric Smoke Detector
(DZ-03 base)
548d/02
Bases:
DZ-03 Standard detector base
Certificate No: 548k-(cl-2) to EN 54-12: 2002
Beam Detectors
Certificated Products
FX9105RI
LPCB Ref.
No.
548k/01
Intelligent optical beam detector
Notes:
1) Meets the requirements of EN 54-12 at the following sensitivity settings:
Level 1 - 1.61 dB
Level 2 - 2.31dB
Certificate No: 548q-(cl-2) to EN 54:5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA 4021: 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
FX9101
FX9101I
LPCB Ref.
No.
548q/01
Conventional Optical Smoke and Heat Multisensor Detector (FX9907, DZ-03D & DZ-03
Bases)
Notes:1. Meets the requirements of EN 54-7: 2000 at sensitivity setting Mode 12.
Meets the requirements of EN 54-5: 2000 at Class A2R
Intelligent Optical Smoke and Heat Multisensor Detector (DZ-03 Base)
Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity setting Mode 12.
Meets the requirements of EN 54-5: 2000 at Class A2R
548q/02
Bases:
DZ-03
Standard Base
DZ-03D Diode Base
FX9907 Active EOL Base
Eurofyre Limited
Unit C1 Knowle Village Business Park, Mayles Lane, Wickham, Fareham PO17 5DY, United Kingdom
Tel: 01329 830 462
E-mail: [email protected]
Certificate No: 1163a-(cl-1) to EN54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
12-020
16-050
Conventional Optical Smoke Detector (12-030 base and 12-031 base)
Note:1. Meets the requirements of EN 54-7:2000 at Smoke Sensitivity setting
range:0.08%dB~ 0.12%dB
Addressable Optical Smoke Detector (12-030 base and 12-031 base)
Note:
1. Meets the requirements of EN 54-7:2000 at Smoke Sensitivity setting range:0.09%dB~
0.11%dB
LPCB Ref.
No.
1163a/01
1163a/02
Bases:
262
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
12-030
12-031
Shallow Base
Deep Base
Certificate No: 1163b-(cl-1) to EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-5:2000 + A1: 2002 & CEA 4021 July 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
12-023
Conventional Optical Heat Detector (12-030 base and 12-031 base)
Note:
1. Meets the requirements of EN 54-7:2000 at Smoke Sensitivity setting range:0.08%dB~
0.12%dB
2. Meets the requirements of EN 54-5:2000 at Class A2
Addressable Optical Heat Detector (12-030 base and 12-031 base)
Note:
1. Meets the requirements of EN 54-7:2000 at Smoke Sensitivity setting range:0.09%dB~
0.12%dB
2. Meets the requirements of EN 54-5:2000 at Class A1
16-053
Bases:
12-030
12-031
LPCB Ref.
No.
1163b/01
1163b/02
Shallow Base
Deep Base
Certificate No: 1163c-(cl-1) to EN54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
12-022
Conventional A2S Heat Detector (12-030 base and 12-031 base)
Note:
1. Meets the requirements of EN 54-5:2000 at Class A2S
Conventional A2R Heat Detector (12-030 base and 12-031 base)
Note:
1. Meets the requirements of EN 54-5:2000 at Class A2R
Addressable A2S Heat Detector (12-030 base and 12-031 base)
Note:
1. Meets the requirements of EN 54-5:2000 at Class A2S
Addressable A1R Heat Detector (12-030 base and 12-031 base)
Note:
1. Meets the requirements of EN 54-5:2000 at Class A1R
12-021
16-052
16-051
Bases:
12-030
12-031
LPCB Ref.
No.
1163c/01
1163c/02
1163c/03
1163c/04
Shallow Base
Deep Base
Eurotech Fire Systems Limited
19/20 Stratfield Park, Elettra Avenue, Waterlooville, Hampshire PO7 7XN, United Kingdom
Tel: +44 (0)203 141 0999 • Fax: +44 (0)239 225 2554
E-mail: [email protected] • Website: www.eurotechfire.com
Certificate No: 041f-(cl-1) to EN54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 842a-(cl-2) to EN54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 1213e to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 1213n to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005
Smoke Detectors
Certificated Products
EURV-P
EURVC-P
20 Oct 2014
Analogue addressable optical smoke detector (EURB-4, EURB-4-EV, EURB-4SD and
EURB-4SE-EV bases)
Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only.
Conventional optical smoke detector
(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)
LPCB Ref.
No.
041f/01
041f/03
263
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
200-404
200-503
100-2210V
100-2101V
EURVC-P
EURV-P
Odyssey Conventional Optical Smoke Detector
(200-300 and 200-301 mounting base)
Odyssey Analogue Addressable Optical Smoke Detector
(200-111 mounting base)
EURVC-P Conventional Optical Smoke Detector
(100-3500V, 100-3511v and 100-3510V bases)
EURV-PI Intelligent Optical Smoke Detector with Short Circuit Isolator
(100-3000V Base)
Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:Optical
only level 1 - HighOptical only level 2Optical only level 3 Optical only level 4 - Low
Conventional optical smoke detector
(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)
Analogue addressable optical smoke detector
(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)
Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only.
LPCB Ref.
No.
1213e/01
1213e/02
1213e/04
1213n/01
842a/01
842a/04
Bases
EURB-4 Universal mounting base
EURB-4-EV Universal mounting base
EURB-4SD Universal mounting base with schottky diode
EURB-4SE-EV Standard deep base
200-300 Odyssey mounting base
200-111 Odyssey mounting base
200-301 Odyssey diode mounting base
100-3000V Low profile adaptor base
Certificate No: 041g-(cl-1) to EN 54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 1999
Certificate No: 041h-(cl-1) to EN54-5: 2000 + A1: 2002
Certificate No: 1213r to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005
Certificate No: 1213d to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
EURV-PH
EURV-H-A1R
EURV-H-CS
EURVC-H-A2S
EURVC-H-CS
200-400
Analogue addressable optical smoke / class A1R heat detector (EURB-4, EURB-4-EV,
EURB-4SD and EURB-4SE-EV bases)
Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings.
Analogue addressable Class A1R heat detector
(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)
Analogue addressable Class CS heat detector
(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)
Conventional Class A2S heat detector
(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)
Conventional Class CS heat detector
(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)
Odyssey Conventional Class A1R Heat Detector
(200-300 mounting base)
Note:
1. Meets the requirements of EN 54: Part 5 - Class A1R
LPCB Ref.
No.
041g/01
041h/01
041h/02
041h/03
041h/04
1213d/01
200-401
Odyssey Conventional Class BR Heat Detector
(200-300 mounting base)
Note:
1. Meets the requirements of EN 54: Part 5 - Class BR
1213d/02
200-402
Odyssey Conventional Class CR Heat Detector
(200-300 mounting base)
Note:
1. Meets the requirements of EN 54: Part 5 - Class CR
1213d/03
200-403
Odyssey Conventional Class CS Heat Detector
(200-300 mounting base)
Note:
1. Meets the requirements of EN 54: Part 5 - Class CS
1213d/04
200-501
Odyssey Analogue Addressable Class A2S Heat Detector
(200-111 mounting base)
1213d/05
264
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
200-502
100-2505V
100-2201V
Odyssey Analogue Addressable Class CS Heat Detector
(200-111 mounting base)
EURV-H Conventional Class P Heat Detector 100-3511v and 100-3510V bases)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B
EURV-H-A1RI Intelligent Class P Heat Detector with Short Circuit Isolator
(100-3000V Base)
Note:
1. Meets the requirements of EN 54-5 for Class A1R, Class B and Class BS
LPCB Ref.
No.
1213d/06
1213d/08
1213r/01
Bases
EURB-4
Universal mounting base
EURB-4-EV
Universal mounting base
EURB-4SD
Universal mounting base with schottky diode
EURB-4SE-EV
Standard deep base
200-300
Odyssey mounting base
200-111
Odyssey mounting base
100-3000V Low profile adaptor base
Certificate No: 1213c to EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003
Certificate No: 1213p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 & CEA 4021: 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
200-505
100-2401V
Odyssey Analogue Addressable Multisensor Detector
(200-111 mounting base)
EURV-PHI Intelligent Multi-Criteria Detector with Short Circuit Isolator
(100-3000V Base)
Notes:
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following
settings:
Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat
response
Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat
response
Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class
A1 heat response
2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
3. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
LPCB Ref.
No.
1213c/01
1213p/01
Bases:
200-111 Odyssey mounting base
100-3000V Low profile adaptor base
Everday Technology Co. Limited
No,.95., Sec. 2., Ligong 1 St. Road., Letzer Industrial Park, Yilan County 26841, Taiwan ROC
Tel: +886 3 990 6099 • Fax: +862 3 990 6029
E-mail: [email protected] • Website: www.everday.com
Certificate No: 512a to EN 54-7: 2000 + A1: 2002 + A2: 2006
20 Oct 2014
265
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Smoke Detectors
Certificated Products
EA318-2
EA318-2(LED)
EA318-4-12
EA318-4-24
EA318-2V
EA318-2-LED-V
EA318-4V-12
EA318-4V-24
Conventional 2 wire photoelectric smoke detector
(P/N852001 base)
Conventional 2 wire photoelectric smoke detector with remote LED output
(P/N854001 base)
Conventional 4 wire photoelectric smoke detector
(P/N854001 base)
Conventional 4 wire photoelectric smoke detector
(P/N854001 base)
Conventional 2 wire photoelectric smoke detector
(P/N852001 base)
Conventional 2 wire photoelectric smoke detector with remote LED output (P/N852001
base)
Conventional 4 wire photoelectric smoke detector
(P/N854001 base)
Conventional 4 wire photoelectric smoke detector
LPCB Ref.
No.
512a/01
512a/02
512a/03
512a/04
512a/05
512a/06
512a/07
512a/08
Bases:
P/N854001 4-wire detector base
P/N852001 2-wire detector base
Certificate No: 512b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003
Multi-criteria Detectors
Certificated Products
EA318-2H
EA318-2H-LED
EA318-4H-12
EA318-4H-24
EA318-2HV
EA318-2H-LED-V
EA318-4HV-12
EA318-4HV-24
Conventional 2 wire photoelectric smoke and heat detector
(P/N852001 base)
Conventional 2 wire photoelectric smoke and heat detector with remote LED output
(P/N854001 base)
Conventional 4 wire photoelectric smoke and heat detector
(P/N854001 base)
Conventional 4 wire photoelectric smoke and heat detector
(P/N854001 base)
Conventional 2 wire photoelectric smoke and heat detector (P/N852001 base)
Conventional 2 wire photoelectric smoke and heat detector with remote LED output
(P/N8524001 base)
Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base)
Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base)
LPCB Ref.
No.
512b/01
512b/02
512b/03
512b/04
512b/05
512b/06
512b/07
512b/08
Bases:
P/N854001 4-wire detector base
P/N852001 2-wire detector base
Certificate No: 512d to EN 54-5: 2000 + A1: 2002
Point Heat Detectors
Certificated Products
EA323-2
EA323-2
EA323-2L
EA323-2L
EA323-4
EA323-4
EA323-4
EA323-4
EA323-2V(A2S)
266
Conventional 2 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector
(P/N852001 base)
Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
(P/N852001 base)
Conventional 2 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector
with LED output (P/N854001 base)
Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
with LED output (P/N854001 base)
Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector
(P/N854001 base)
Conventional 4 wire 12VDC class A2R fixed temperature and rate-of-rise heat detector
(P/N854001 base)
Conventional 4 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector
(P/N854001 base)
Conventional 4 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
(P/N854001 base)
Conventional 2 wire 24 VDC class A2S fixed temperature and rate-of-rise heat detector
LPCB Ref.
No.
512d/01
512d/02
512d/03
512d/04
512d/05
512d/06
512d/07
512d/08
512d/09
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
EA323-2V(A2R)
EA323-2LV(A2S)
EA323-2LV(A2R)
EA323-4V-12(A2S)
EA323-4V-12(A2R)
EA323-4V-24(A2S)
EA323-4V-24(A2R)
LPCB Ref.
No.
(P/N852001 base)
Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
(P/N852001 base)
Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector
(P/N854001 base)
Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
with LED output (P/N852001 base)
Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector
(P/N854001 base)
Conventional 4 wire 12VDC class A2R fixed temperature and rate-of-rise heat detector
(P/N854001 base)
Conventional 4 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector
(P/N854001 base)
Conventional 4 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
(P/N854001 base)
512d/10
512d/11
512d/12
512d/13
512d/14
512d/15
512d/16
Bases:
P/N852001 2-Wire detector base
P/N854001 4-Wire detector base
Fike Safety Technology Ltd
Unit 31, Springvale Industrial Estate, Cwmbran, Gwent NP44 5BD, United Kingdom
Tel: +44 (0)1633 865558 • Fax: +44 (0)1633 866656
E-mail: [email protected] • Website: www.fikesafetytechnology.co.uk
Certificate No: 331f to EN 54-3: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006,
EN 54-17: 2005, EN 54-18: 2005 and CEA 4021:July 2003 (en)
Certificate No: 331n to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006,
EN 54-17:2005, EN 54-18: 2005 and CEA 4021:July 2003 (en)
Certificate No: 331g to EN 54-3: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and
CEA 4021: July 2003 (en)
Certificate No: 331p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: July 2003 (en)
Certificate No: 331u to EN 54-5:2000 + A1:2002 & EN 54-7:2000 + A1:2002 + A2:2006 & CEA 4021: 2003
Multi-Sensor Detectors
Certificated Products
205-0001
Sita analogue addressable optical smoke and heat multisensor detector with short circuit
isolator and sounder.
Notes:
1.
Meets the requirements of EN 54-5:2000 at the following settings:
HM1 Class A1 standard temperature rate of rise enhanced
HM2 Class A1 standard temperature, fixed temperature.
2.
LPCB Ref.
No.
331f/01
Meets the requirements of EN 54-7:2000 at the following settings:
SM1 Standard optical sensitivity with high thermal enhancement
SM2 Standard optical sensitivity with normal thermal enhancement.
3.
205-0012
Approved at the following tones SP1
Continuous 970Hz
SP2
Pulsed 970Hz 1s on 1s off
SP3
Dual Tone 970Hz 0.25s , 800Hz 0.25s
SP4*
Sweep Up 800-970Hz over 1s
SP5
Slow Whoop 500-1200Hz over 3s, 0.5s off
SP6*
Sweep Down 1200-500Hz over 1s
SP7
Dual French 550Hz 0.1s, 440Hz 400ms
* Not available if the I/O facility is used.
Sita analogue addressable optical smoke and heat multisensor detector with short circuit
isolator and sounder/strobe.
Notes:
1.
Meets the requirements of EN 54-5:2000 at the following settings:
HM1 Class A1 standard temperature rate of rise enhanced
HM2 Class A1 standard temperature, fixed temperature.
2.
20 Oct 2014
331f/02
Meets the requirements of EN 54-7:2000 at the following settings:
SM1 Standard optical sensitivity with high thermal enhancement
SM2 Standard optical sensitivity with normal thermal enhancement.
267
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
3.
202-0001
Approved at the following tones SP1
Continuous 970Hz
SP2
Pulsed 970Hz 1s on 1s off
SP3
Dual Tone 970Hz 0.25s , 800Hz 0.25s
SP4*
Sweep Up 800-970Hz over 1s
SP5
Slow Whoop 500-1200Hz over 3s, 0.5s off
SP6*
Sweep Down 1200-500Hz over 1s
SP7
Dual French 550Hz 0.1s, 440Hz 400ms
* Not available if the I/O facility is used.
4.
The strobe function is not approved.
Twinflex conventional optical smoke and heat multisensor detector with sounder
Notes:
1. Meets the requirements of EN 54-5:2000 at the following settings:
HM1 Class A1 standard temperature rate of rise enhanced
HM2 Class A1 standard temperature, fixed temperature.
331g/01
2. Meets the requirements of EN 54-7:2000 at the following settings:
SM1 Standard optical sensitivity with high thermal enhancement
SM2 Standard optical sensitivity with normal thermal enhancement.
204-0001
204-0012
205-0003
3. Approved at the following tones SP1
Continuous 970Hz
SP2
Alternating Tone 800 0.25s / 970Hz 0.25s
SP3
Sweep Up 800-970Hz over 1s
Twinflex Multipoint ASD Conventional Optical Smoke and Heat Multisensor Detector with
Type A Sounder (45-0048-202-01 Base)
Notes:
1. Meets the requirements of EN 54-5:2000 at the following settings:
HM1 Class A1 standard temperature rate of rise enhanced
HM2 Class A1 standard temperature, fixed temperature
HM3 Class C standard temperature, fixed temperature
2. Meets the requirements of EN 54-7:2000 at the following settings:
SM1 Standard optical sensitivity with high thermal enhancement
SM2 Standard optical sensitivity with normal thermal enhancement
3. Approved at the following tones SP1 Continuous 970Hz
SP2 Pulsed 970Hz 1s on, 1s off
SP3 Dual Tone 970Hz 0.25s / 800Hz 0.25s
Twinflex Multipoint ASD Conventional Optical Smoke and Heat Multisensor Detector with
Type A Sounder & Strobe
Notes:
1. Meets the requirements of EN 54-5:2000 at the following settings:
HM1 Class A1 standard temperature rate of rise enhanced
HM2 Class A1 standard temperature, fixed temperature
HM3 Class C standard temperature, fixed temperature
2. Meets the requirements of EN 54-7:2000 at the following settings:
SM1 Standard optical sensitivity with high thermal enhancement
SM2 Standard optical sensitivity with normal thermal enhancement
3. Approved at the following tones SP1 Continuous 970Hz
SP2 Pulsed 970Hz 1s on, 1s off
SP3 Dual Tone 970Hz 0.25s / 800Hz 0.25s
4. The strobe function is not approved to EN 54-23:2010
Sita analogue addressable optical smoke and heat multisensor detector with short circuit
isolator.
Notes:
1.
Meets the requirements of EN 54-5:2000 at the following settings:
HM1 Class A1 standard temperature rate of rise enhanced
HM2 Class A1 standard temperature, fixed temperature.
331g/03
331n/01
2.
202-0003
Meets the requirements of EN 54-7:2000 at the following settings:
SM1 Standard optical sensitivity with high thermal enhancement
SM2 Standard optical sensitivity with normal thermal enhancement.
Twinflex conventional optical smoke and heat multisensor detector
Notes:
1. Meets the requirements of EN 54-5:2000 at the following settings:
HM1 Class A1 standard temperature rate of rise enhanced
HM2 Class A1 standard temperature, fixed temperature.
331g/02
331p/01
2. Meets the requirements of EN 54-7:2000 at the following settings:
268
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
204-0003
200-0013
LPCB Ref.
No.
SM1 Standard optical sensitivity with high thermal enhancement
SM2 Standard optical sensitivity with normal thermal enhancement.
Twinflex Multipoint ASDConventional Optical Smoke and Heat Multisensor Detector (450048-202-01 Base)
Notes:
1.
Meets the requirements of EN 54-5:2000 at the following settings:
HM1 Class A1 standard temperature rate of rise enhanced
HM2 Class A1 standard temperature, fixed temperature
HM3 Class C standard temperature, fixed temperature
2. Meets the requirements of EN 54-7:2000 at the following settings:
SM1 Standard optical sensitivity with high thermal enhancement
SM2 Standard optical sensitivity with normal thermal enhancement
Conventional Optical Heat Detector
Note:
1. Meets the requirements of EN 54-7:2000 at Smoke Sensitivity setting
Range:0.08%dB~ 0.12%dB 2. Meets the requirements of EN 54-5:2000 at Class A2
331p/02
331u/01
Bases
45-0048-202 ASD Base
45-0048-202-01 Standard Base
25-0065-202 Base extension
45-0306-202 Twinflex Multipoint Base
200-0014 Shallow Base
Certificate No: 331t to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
200-0010
Conventional Optical Smoke Detector
Note:
1. Meets the requirements of EN 54-7:2000 at Smoke Sensitivity setting
Range:0.08%dB~ 0.12%dB
LPCB Ref.
No.
331t/01
Base
200-0014 Shallow Base
Certificate No: 331s to EN 54-5: 2000 + A1:2002
Heat Detectors
Certificated Products
200-0012
200-0011
Conventional A2S Heat Detector
Note:
1. Meets the requirements of EN 54-5: 2000 at Class A2S
Conventional A2R Heat Detector
Note:
1. Meets the requirements of EN 54-5: 2000 at Class A2R
LPCB Ref.
No.
331s/01
331s/02
Base
200-0014 Shallow Base
20 Oct 2014
269
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Finder Elektronik A.S.
Liman Mah., 6. Sok., No: 10 07070, Konyaalti, Antalya, Turkey
Tel: +9 0242 344 2500 • Fax: +9 0242 344 2120
E-mail: [email protected] • Website: www.finder.com.tr
Certificate No: 928a-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54 -17: 2005
Certificate No: 928d-(cl-1) to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
FF T200
Analogue addressable Class P heat detector with short circuit isolator (FF BS200 base)
Notes
1. Meets the requirements of EN 54-5 for Class A1R and Class B
Analogue addressable Class P, temperature detector (FF BS200 base)
Notes
1. Meets the requirements of EN 54-5 for Class A1R and Class B
Conventional Class P, heat detector (FF UBR200 and FF BRD200 bases)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B.
FF T200L
FF T1000
Bases
FF BS200
FF UBR200
FF BRD200
LPCB Ref.
No.
928a/01
928d/01
928d/02
Mounting base (with link resistor)
Universal adaptor base with resistor
Universal adaptor base with resistor and Schottky diode
Certificate No: 928b-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005
Certificate No: 928e-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 928k-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008
Smoke Detectors
Certificated Products
FF O200
FF O200L
FF O1000
FF SG100
Bases
FF BS200
FF UBR200
FF BRD200
WAB100
270
Analogue addressable photoelectric smoke detector with short circuit isolator (FF BS200
base)
Notes
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Analogue addressable optical smoke detector (FF BS200 base)
Notes
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Conventional photo smoke detector (FF UBR200 and FF BRD200 bases)
Wireless optical smoke detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-7 in the normal sensitivity setting
2. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928b/01
928e/01
928e/02
928k/01
Mounting base (with link resistor)
Universal adaptor base with resistor
Universal adaptor base with resistor and Schottky diode
Wireless Adaptor Base
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 928c-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA 4021: 2003
Certificate No: 928f-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Multi-sensor Detectors
Certificated Products
FT OT200
Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with
short circuit isolator (FF BS200 base)
Notes:
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:
Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection
with Class A1 heat response
Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1
heat response
Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1
heat response
Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection
with Class A1 heat response
2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
3. Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Analogue addressable optical smoke detector (FF BS200 base)
Notes
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
FF OT200L
Bases
FF BS200
LPCB Ref.
No.
928c/01
928f/01
Mounting base (with link resistor)
Certificate No: 928j-(cl-5) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008
Point Heat Detectors
Certificated Products
FF SG350
Bases:
WAB100
Wireless heat detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1R
2. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928j/01
Wireless Adaptor Base
Certificate No: 928m-(cl-5) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
FF SG200
Bases:
WAB100
20 Oct 2014
Wireless multi-criteria detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1
2. Meets the requirements of EN 54-7 in the normal sensitivity setting
3. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928m/01
Wireless Adaptor Base
271
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Fire Fighting Enterprises Ltd
9 Hunting Gate, Hitchin, Hertfordshire SG4 0TJ, United Kingdom
Tel: +44 (0) 1462 444740 • Fax: +44 (0) 1462 444789
E-mail: [email protected] • Website: www.ffeuk.com
Certificate No: 1204a to EN 54-10: 2002 + A1: 2005
Commercial detectors -1 - 1 - 4
Certificated Products
16511
16519
16521
16571
16579
16581
16589
16591
Talentum Conventional IR2 (Exd) Flameproof Flame Detector
(07127 Bracket)
Note:
1.) Meets the requirements of EN 54-10: 2002 at Class 1 only
Talentum Conventional IR3 (Exd) Flameproof Flame Detector
(07127 Bracket)
Note:
1.) Meets the requirements of EN 54-10: 2002 at Class 1 only
Talentum Conventional UV/IR2 (Exd) Flameproof Flame Detector (07127 Bracket)
Note:
1.) Meets the requirements of EN 54-10: 2002 at Class 1 only
Talentum Conventional IR2 (IS) Intrinsically Safe Flame Detector (07127 Bracket)
Note:
1.) Meets the requirements of EN 54-10: 2002 at Class 1 only
Talentum Conventional IR3 (IS) Intrinsically Safe Flame Detector (07127 Bracket)
Note:
1.) Meets the requirements of EN 54-10: 2002 at Class 1 only
Talentum Conventional IR2 Flame Detector (07127 Bracket)
Note:
1.) Meets the requirements of EN 54-10: 2002 at Class 1 only
Talentum Conventional IR3 Flame Detector (07127 Bracket)
Note:
1.) Meets the requirements of EN 54-10: 2002 at Class 1 only
Talentum Conventional UV/IR2 Flame Detector (07127 Bracket)
Note:
1.) Meets the requirements of EN 54-10: 2002 at Class 1 only
LPCB Ref.
No.
1204a/05
1204a/06
1204a/07
1204a/08
1204a/09
1204a/10
1204a/11
1204a/12
07127 Adjustable Mounting Bracket
Fireguard Safety Equipment Co Ltd
2nd Floor, 145-147 St John Street, London EC1V 4PY, United Kingdom
Tel: +44 (0)8450 751042 • Fax: +44 (0)845 2991039
E-mail: [email protected] • Website: www.fireguard-uk.com
Certificate No: 512a-(cl-4) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 928e-(cl-7) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 1138a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificated Products
FG-413SD-4
FG-413SD-2
Fireguard FG318-2L
FGSD100
272
Conventional 4-WIRE Photoelectric Smoke Detector with Relay Output (B-01 base)
Conventional 2-WIRE Photoelectric Smoke Detector with Remote LED (B-01 base)
Conventional 2 wire photoelectric smoke detector with remove LED output (Fireguard
P/N FG854001 base)
Analogue addressable photoelectric smoke detector lite (VB100, UB100, VB100S,
UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases)
Note:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
LPCB Ref.
No.
1138a/03
1138a/04
512a/02
928e/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Bases
VB100
UB100
VB100S
UB100S
VDBS100
DBS100
VDBS100S
DBS100S
Fireguard P/N FG854001
B-01
Vega adaptor base (with link resistor)
Universal adaptor base
Vega adaptor base with shorting clip
Universal adaptor base with shorting clip
Vega deep adaptor base
Deep adaptor base
Vega deep adaptor base with shorting clip
Deep adaptor base with shorting clip
4 wire detector base
Standard Base
Certificate No: 512d-(cl-4) to EN54-5: 2000 + A1: 2002
Certificate No: 928d-(cl-7) to EN 54-5: 2000 + A1: 2002
Certificated Products
Fireguard FG323-2L
FGHD350
Bases
VB100
UB100
VB100S
UB100S
VDBS100
DBS100
VDBS100S
DBS100S
Fireguard P/N FG854001
Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
with LED output (Fireguard P/N FG854001 base)
Analogue addressable Class P heat detector lite (VB100, UB100, VB100S, UB100S,
VDBS100, DBS100, VDBS100S and DBS100S bases)
Note:
1.
Meets the requirements of EN 54-5 for Class A1R and Class B
LPCB Ref.
No.
512d/04
928d/01
Vega adaptor base (with link resistor)
Universal adaptor base
Vega adaptor base with shorting clip
Universal adaptor base with shorting clip
Vega deep adaptor base
Deep adaptor base
Vega deep adaptor base with shorting clip
Deep adaptor base with shorting clip
4 wire detector base
Firelite by Honeywell (Pittway Systems Technology Group (Europe) Ltd)
Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom
Tel: +44 1444 230 300 • Fax: +44 1444 230 888
E-mail: [email protected]
Certificate No: 550a to EN 54-7: 2000 + A1: 2002
Certificate No: 550b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 and CEA 4021: 1999
Certificate No: 550c to EN 54-5: 2000 + A1: 2002
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
FL/1003
FL/1002
FL/1005
Conventional photoelectric smoke detector
(FL/1000B base)
Conventional optical/thermal detector
(FL/1000B base)
Notes:
1. Meets the requirements of EN54-5 at class A1R at pre-set sensitivity.
Conventional Class A1R rate of rise heat detector
(FL/1000B base)
LPCB Ref.
No.
550a/02
550b/02
550c/03
Bases
FL/1000B standard base
20 Oct 2014
273
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Fireonica Co. Ltd
2 The Dingle, Wolverhampton WV3 9ET, United Kingdom
Tel: 01902 762 163 • Fax: 0845 299 1039
E-mail: [email protected]
Certificate No: 928d-(cl-8) to EN 54-5: 2000 + A1: 2002
Certificate No: 928e-(cl-8) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificated Products
FOHD350
Analogue addressable Class P heat detector lite (VB100, UB100, VB100S, UB100S,
VDBS100, DBS100, VDBS100S and DBS100S bases)
Note:
1.
Meets the requirements of EN 54-5 for Class A1R and Class B
Analogue addressable photoelectric smoke detector lite (VB100, UB100, VB100S,
UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases)
Note:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
FOSD100
Bases
VB100
UB100
VB100S
UB100S
VDBS100
DBS100
VDBS100S
DBS100S
LPCB Ref.
No.
928d/01
928e/01
Vega adaptor base (with link resistor)
Universal adaptor base
Vega adaptor base with shorting clip
Universal adaptor base with shorting clip
Vega deep adaptor base
Deep adaptor base
Vega deep adaptor base with shorting clip
Deep adaptor base with shorting clip
Fsc Export Ltd
Northolt UB5 5BX, United Kingdom
Tel: +44 7086465266
E-mail: [email protected]
Certificate No: 506a-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificated Products
FS-CSD-311-2
FS-CSD-311-3
FS-CSD-311-4
wire) Conventional Photoelectric Smoke Detector (AHMB-031 Base)
wire) Conventional Photoelectric Smoke Detector (AHMB-031 Base)
wire) Conventional Photoelectric Smoke Detector (AHMB-031 Base)
LPCB Ref.
No.
506a/02
506a/03
506a/04
Base:
AHMB-031 Mounting Base
Certificate No: 506b-(cl-4) to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002, CEA 4021: 2003
Certificated Products
FS-CMD-300-2
FS-CMD-300-3
FS-CMD-300-4
wire) Optical Smoke and Class A2 Heat Detector (AHMB-031 Base)
wire) Optical Smoke and Class A2 Heat Detector (AHMB-031 Base)
wire) Optical Smoke and Class A2 Heat Detector (AHMB-031 Base)
LPCB Ref.
No.
506b/01
506b/02
506b-03
Base:
AHMB-031 Mounting Base
274
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 506c-(cl-5) to EN 54-5: 2000 + A1: 2002
Certificated Products
FS-CTD-805-2
FS-CTD-805-3
FS-CTD-805-4
Wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB-031
Base)
Wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB-031
Base)
Wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB-031
Base)
LPCB Ref.
No.
506c/01
506c/02
506c/03
Base:
AHMB-031 Mounting Base
Gent By Honeywell (Novar Systems Ltd)
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom
Tel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300
E-mail: [email protected] • Website: www.gent.co.uk
Middle East Sales Enquiries:
E-mail: [email protected]
Certificate No: 042bd to EN54-7: 2000+A1: 2002+A2: 2006, EN54-17: 2005, EN54-18: 2005
Certificate No: 042az to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
17840-01
Conventional optical smoke detector (17800-01, 17800-02, 17801-01, 17801-02
mounting bases)
S4-715
S-Quad analogue addressable optical smoke detector Standard base with or without S4FLUSH semi-flush fixing kit)
Note:
1) Meets the requirements of EN 54: Part 7 at the following settings:
State 0 - Medium optical
LPCB Ref.
No.
042az/01
042bd/01
Bases:
78200-01NM standard base
17800-01 standard base
17801-01 standard base with diode
17800-02 low profile base
17801-02 low profile base with diode
S4-700 Standard base
S4-FLUSH Semi-flush fixing kit
Certificate No: 567b to BS 5445: Part 5: 1977 This certificate is to a withdrawn standard. Detectors conforming to this standard
are not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is
maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the
EU.
Certificate No: 042ak to EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002 + A2: 2006, EN 54-17: 2005 and EN 54-18: 2005
Certificate No: 042be to EN54-5: 2000+A1: 2002, EN54-17: 2005, EN54-18: 2005
Certificate No: 042ay to EN 54-5: 2000 + A1: 2002
Point Heat Detectors
Certificated Products
S4-780
20 Oct 2014
S-Quad analogue addressable Class P heat detector with sounder (S4-700 Standard
base with or without
S4-FLUSH semi-flush mounting kit)
Notes:
1) Meets the requirements of EN 54: Part 5 at the following settings:
State 0 - Class A1
LPCB Ref.
No.
042ak/01
275
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
S4-720-ST-VO
S4-780-ST
LPCB Ref.
No.
State 5 - Class B
2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
S-Quad analogue addressable Class P heat detector with strobe and speech
(S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit
Note:
1. Meets the requirements of EN 54: Part 5 at the following settings:
State 0 - Class A1
State 5 - Class B
2. Meets the requirements of EN 54: Part 3 at the following
sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
3. Strobe not included in scope of approval.
4. Speech function is not approved against Annex C requirements of EN 54-3
042ak/02
S-Quad analogue addressable Class P heat detector with sounder and strobe
(S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)
Notes:
1. Meets the requirement of EN 54: Part 5 at the following settings:
State 0 - Class A1
State 5 - Class B
2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
3. Strobe not included in scope of approval.
Conventional Class A1 fixed temperature heat detector (17800-01, 17800-02, 17801-01,
17801-02 mounting bases)
042ak/03
17860-01
Conventional Class A1 rate of rise heat detector (17800-01, 17800-02, 17801-01, 1780102 mounting bases)
042ay/02
S4-720
S-Quad analogue addressable Class P heat detector (S4-700 Standard base with or
without S4-FLUSH semi-flush mounting kit)
Note:
Meets the requirement of EN 54: Part 5 at the following settings:
State 0 - Class A1
State 5 - Class B
Conventional grade 1 fixed temperature heat detector (17800-01, 17801-01, 17800-02
and 17801-02 bases)
Note: This product is certificated to a withdrawn standard. Detectors conforming to this
standard are not suitable for use within the jurisdiction of the European Union (EU). The
certification, to the withdrawn standard, is maintained because detectors meeting the
withdrawn standard requirements are still requested by some regulators outside the EU.
Conventional grade 1 rate-of-rise heat detector (17800-01, 17801-01, 17800-02 and
17801-02 bases)
Note: This product is certificated to a withdrawn standard. Detectors conforming to this
standard are not suitable for use within the jurisdiction of the European Union (EU). The
certification, to the withdrawn standard, is maintained because detectors meeting the
withdrawn standard requirements are still requested by some regulators outside the EU.
042be/01
17850-01
17850-01
17860 -01
042ay/01
567b/01
567b/02
Bases:
17800-01 standard base
17801-01 standard base with diode
17800-02 low profile base
17801-02 low profile base with diode
S4-700 standard base
S4-FLUSH semi-flush fixing kit
276
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 042am to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and EN 54-18: 2005 and
CEA 4021:2003
Certificate No: 042an to EN 54-5: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1:2002 + A2: 2006, EN
54-17: 2005, EN 54-18: 2005 and CEA 4021: 2003
Certificate No: 042bf to EN54-5: 2000+A1: 2002, EN54-7: 2000+A1: 2002+A2: 2006, EN54-17: 2005, EN54-18: 2005
Certificate No: 042bv to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN54-17: 2005, EN54-18: 2005, EN54-23:
2010
Certificate No: 042ca to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006,
EN54-17: 2005, EN54-18: 2005,
Certificate No: 042bu to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006,
EN54-17: 2005, EN54-18: 2005,
Certificate No: 042bz to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005,
Certificate No: 042bw to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005, EN54-23:
2010
Certificate No: 042ak to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005,
Multi-criteria Detectors
Certificated Products
S4-780-S
S4-711-ST
S4-911
S4-711-ST-VO
S4-771
S4-911-ST-VO
20 Oct 2014
Analogue Addressable Class P Heat Sensor with Sounder (S4-701 Base)
Notes:1. Meets the requirements of EN 54-3 at the following tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-3:2001 at the following settings:
State 0 - Class A1 heat
State 5 - Class B heat
3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector
with strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)
Notes:
1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the
following settings:
State 0 - Medium optical / Class A1 heat
State 5 - Medium optical / Class B heat
State 8 - Delayed medium optical / Class A1 heat
2) The strobe function is not included within the scope of this approval
S-Quad analogue addressable dual optical smoke, Class P heat and carbon monoxide
multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush
mounting kit)
Notes:
1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the
following settings:
State 0 - Medium optical / Class A1 heat
2) Meets the requirements of EN 54: Part 5 at the following settings:
State 9 - Class A1 heat
3) Carbon monoxide detection is not included within the scope of this approval
S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector
with speech and
strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)
Notes:
1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the
following settings:
State 0 - Medium optical / Class A1 heat
State 5 - Medium optical / Class B heat
State 8 - Delayed medium optical / Class A1 heat
2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
3) Speech function is not approved against Annex C requirements of EN 54-3
S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector
with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)
Notes:
1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the
following settings:
State 0 - Medium optical / Class A1 heat
State 5 - Medium optical / Class B heat
State 8 - Delayed medium optical / Class A1 heat
2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
S-Quad analogue addressable optical smoke, heat and carbon monoxide multisensor
detector
LPCB Ref.
No.
042ak/04
042am/02
042am/03
042an/01
042an/02
042an/03
277
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
S4-770
S4-711-VO
S4-770-ST
S4-710
S4-711
S4-911-V-VAD-HPR
278
LPCB Ref.
No.
with speech and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush
mounting kit)
Notes:
1) Meets the requirements of EN 54: Part 5 and requirements of EN 54: Part 7 at the
following settings:
State 0 - Medium optical / Class A1 heat
2) Meets the requirements of EN 54: Part 5 at the following settings:
State 9 - Class A1 heat
3) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
4) Carbon monoxide detection, speech and strobe not included within the scope of this
approval
5) Speech function is not approved against Annex C requirements of EN 54-3
S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector
with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)
Note:
1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the
following settings:
State 0 - Medium optical / Class A1 heat
2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector
with speech (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)
Note:
1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the
following settings:
State 0 - Medium optical / Class A1 heat
State 5 - Medium optical / Class B heat
State 8 - Delayed medium optical / Class A1 heat
2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
3) Speech function is not approved against Annex C requirements of EN 54-3
S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector
with sounder and strobe
Standard base with or without S4-FLUSH semi-flush mounting kit)
Notes:
1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the
following settings:
State 0 - Medium optical / Class A1 heat
2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
3) Strobe not included in scope of approval.
S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector
(S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)
Note:
1)
Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at
the following settings:
State 0 - Medium optical / Class A1 heat
S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector
(S4-700 Standard base with or without S4-FLUSH semi-flush fixing kit)
Notes:
1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the
following settings:
State 0 - Medium optical / Class A1 heat
State 5 - Medium optical / Class B heat
State 8 - Delayed medium optical / Class A1 heat
Analogue Addressable Dual Optical Smoke and Class P Heat and CO Multi-Sensor
Detector with Speech, Sounder and Red Visual Alarm (S4-701 Base)
Notes:
1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High- Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 - Medium Optical / Class A1 Heat
State 9 - Class A1 Heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23
for the following:
042an/04
042an/05
042an/06
042bf/01
042bf/02
042bu/04
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
S4-911-V-VAD-HPW
S4-711-V-VAD-HPR S4711-V-VAD-HPR
S4-711-V-VAD-LPW
S4-711-V-VAD-HPW
20 Oct 2014
LPCB Ref.
No.
- Category (light pattern details)
@ High power setting - (Category C: C-3-14 and Category O: O-4.5-14)
@ Medium power setting - (Category C: C-3-13 and Category O: O-4-13)
@ Low power setting - (Category C: C-3-10 and Category O: None)
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Dual Optical Smoke and Class P Heat and CO Multi-Sensor
Detector with Speech, Sounder and White Visual Alarm (S4-701 Base)
Notes:
1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High- Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 - Medium Optical / Class A1 Heat
State 9 - Class A1 Heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23
for the following:
- Category (light pattern details)
@ High power setting - (Category C: C-6-16 and Category O: None)
@ Medium power setting - (Category C: C-3-14 and Category O: O-5-14)
@ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with
Speech, Sounder and Red Visual Alarm (S4-701 Base)
Notes:
1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High- Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 - Medium Optical / Class A1 Heat
State 5 - Medium Optical / Class B Heat
State 8 - Delayed Medium Optical / Class A1 Heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23
for the following:
- Category (light pattern details)
@ High power setting - (Category C: C-3-14 and Category O: O-4.5-14)
@ Medium power setting - (Category C: C-3-13 and Category O: O-4-13)
@ Low power setting - (Category C: C-3-10 and Category O: None)
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with
Speech, Sounder and White Visual Alarm (S4-701 Base)
Notes:
1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High- Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 - Medium Optical / Class A1 Heat
State 5 - Medium Optical / Class B Heat
State 8 - Delayed Medium Optical / Class A1 Heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23
for the following:
- Category (light pattern details)
@ Low power setting - (Category C: C-3-10 and Category O: None)
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with
Speech, Sounder and White Visual Alarm (S4-701 Base)
Notes:
1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High- Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 - Medium Optical / Class A1 Heat
State 5 - Medium Optical / Class B Heat
State 8 - Delayed Medium Optical / Class A1 Heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23
042bu/05
042bu/06
042bu/07
042bu/08
279
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
S4-720-V-VAD-HPR
S4-720-V-VAD-HPW
S4-711-VAD-HPR
LPCB Ref.
No.
for the following:
- Category (light pattern details)
@ High power setting - (Category C: C-6-16 and Category O: None)
@ Medium power setting - (Category C: C-3-14 and Category O: O-5-14)
@ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Class P Heat Sensor with Voice, Sounder and Red Visual Alarm
(S4-701 Base)
Notes:
1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 at the following settings:
State 0 - Class A1 heat
State 5 - Class B heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of
EN 54-23 for the following:
- Category (light pattern details)
@ High power setting - (Category C: C-3-14 and Category O: O-4.5-14)
@ Medium power setting - (Category C: C-3-13 and Category O: O-4-13)
@ Low power setting - (Category C: C-3-10 and Category O: None)
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Class P Heat Sensor with Voice, Sounder and White Visual Alarm
(S4-701 base)
Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 at the following settings:
State 0 - Class A1 heat
State 5 - Class B heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN
54-23 for the following:
- Category (light pattern details)
@ High power setting - (Category C: C-6-16 and Category O: None)
@ Medium power setting - (Category C: C-3-14 and Category O: O-5-14)
@ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21CNotes:
Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with
Red Visual Alarm (S4-701 base)
Notes:1. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 -Medium optical / Class A1 heat
State 5 - Medium optical / Class B Heat
State 8 - Delayed medium optical / Class A1 heat
042bv/01
042bv/02
042bw/01
2. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23
for the following:
- Category (light pattern details)
@ High power setting - (Category C: C-3-14 and Category O: O-4.5-14)
@ Medium power setting - (Category C: C-3-13 and Category O: O-4-13)
@ Low power setting - (Category C: C-3-10 and Category O: None)
- Synchronization
- Flash rate 2 seconds (0.5Hz)
S4-711-VAD-LPW
3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with
White Visual Alarm (S4-701 base)
Notes:
1. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 -Medium optical / Class A1 heat
State 5 - Medium optical / Class B Heat
State 8 - Delayed medium optical / Class A1 heat
042bw/02
2. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23
for the following:
- Category (light pattern details)
@ Low power setting - (Category C: C-3-10 and Category O: None)
280
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
- Synchronization
- Flash rate 2 seconds (0.5Hz)
S4-711-VAD-HPW
3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with
White Visual Alarm (S4-701 base)
Note:1. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 -Medium optical / Class A1 heat
State 5 - Medium optical / Class B Heat
State 8 - Delayed medium optical / Class A1 heat
042bw/03
2. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23
for the following:
- Category (light pattern details)
@ High power setting - (Category C: C-6-16 and Category O: None)
@ Medium power setting - (Category C: C-3-14 and Category O: O-5-14)
@ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8)
- Synchronization
- Flash rate 2 seconds (0.5Hz)
S4-901
S4-711-V
S4-771-S
S4-770-S
3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Dual Optical Smoke and Class P Heat and CO Multi-Sensor
Detector Base)
Notes:
1. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 - Medium optical / Class A1 heat
State 9 - Class A1 heat
2. Carbon Monoxide Detection is not included in the scope of this approval.
3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with
Speech (S4-701 base)
Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 -Medium optical / Class A1 heat
State 5 - Medium optical / Class B Heat
State 8 - Delayed medium optical / Class A1 heat
3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Dual Optical Smoke and Class P Heat Multi-Sensor Detector with
Sounder (S4-701 base)
Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 -Medium optical / Class A1 heat
State 5 - Medium optical / Class B Heat
State 8 - Delayed medium optical / Class A1 heat
3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with
Sounder (S4-701 base)
Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 -Medium optical / Class A1 heat
3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
042bz/01
042ca/01
042ca/02
042ca/03
Bases:
S4-700 standard base
S4-701 S Quad plate and base
S4-FLUSH semi-flush fixing kit
Certificate No: 042bh to EN 54-12: 2002 and EN 54-17: 2005
Beam Detectors
Certificated Products
S4-34740
20 Oct 2014
Analogue addressable optical beam smoke detector with short circuit isolator
LPCB Ref.
No.
042bh/01
281
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
( S4-34741-01 and S4-34741-03)
Notes:
1. The S4-34740 beam sensor pair comprises of an S4-34741 beam transmitter,
plus an S4-34742 beam receiver.
2. Meets the requirements of EN 54-12 at the following sensitivity settings:
States 0, 1: 3.01dB
States 2, 3: 1.25dB
Ancillaries:
S4-34741-01 beam angle bracket
S4-34741-03 beam parallel bracket
GEZE GmbH
Reinhold-Vöster-Str. 21-29, D-71229 Leonberg, Germany
Tel: +49 (0)7152-203-0 • Fax: +49 (0)7152-203-310
E-mail: [email protected] • Website: www.geze.com
Certificate No: 928d-(cl-10) to EN 54-5: 2000 + A1: 2002
Point Heat Detectors
Certificated Products
GC003 D
Base
GC160 B
Conventional non-latching Class P heat detector (GC 150B relay base and GC160 B
base)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B
LPCB Ref.
No.
928d/02
Universal adaptor base
Certificate No: 928e-(cl-10) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
GC002 D
Conventional non-latching photo smoke detector (GC150 B relay base and GC160 B
base)
LPCB Ref.
No.
928e/02
Bases
GC150 B Non-latching relay base
GC160 B Universal adaptor base
Gulf Security Technology Co., Ltd.
No 80 Changjiang East Road, QETDZ, Qinhuangdao, Hebei Province 066004, China
Tel: +86 0335 8502434 • Fax: +86 0335 8502532
E-mail: [email protected] • Website: www.gst.com.cn
Sales Enquiries:
Tel: +852 28778566 • Fax: +852 25118699
Tel: +86 (10)64392919 • Fax: +86 (10)64391767
Certificate No: 548c to EN 54-5: 2000 + A1: 2002
282
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Point Heat Detectors
Certificated Products
C-9103
I-9103
DC-9103E
Conventional Class A1R heat detector (DZ-03 base)
Intelligent Class A1R Rate of Rise Heat Detector (DZ-03 base)
Conventional Rate of Rise and Fixed Temperature Heat Detector (DB-01 & DB-01D
Bases and DP-9907 Unit)
Note:
1. Meets the requirements of EN 54-5:2000 for Class A1R, A2S & BS
Intelligent Rate of Rise and Fixed Temperature Heat Detector (DB-01 Base)
Note:
1. Meets the requirements of EN 54-5:2000 for Class A1R, A2S & BS
DI-9103E
Bases:
DZ-03
DB-01
DB-01D
DP-9907
LPCB Ref.
No.
548c/01
548c/02
548c/03
548c/04
Standard detector base
Standard Base
Diode Base
Active End of Line Unit
Certificate No: 548d to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detector
Certificated Products
C-9102
I-9102
DC-9102E
Conventional Photoelectric Smoke Detector (DZ-03 base)
Intelligent Photoelectric Smoke Detector (DZ-03 base)
Conventional Photoelectric Smoke Detector (DB-01 & DB-01D Bases and DP-9907 Unit)
Note:1. Meets the requirements of EN 54-7:2000 at sensitivity level 1 (default) setting
only
Intelligent Photoelectric Smoke Detector (DB-01 Base)
Note:
1. Meets the requirements of EN 54-7:2000 at sensitivity level 1 (default) setting only
DI-9102E
Bases:
DZ-03
DB-01
DB-01D
DP-9907
LPCB Ref.
No.
548d/01
548d/02
548d/03
548d/04
Standard detector base
Standard Base
Diode Base
Active End of Line Unit
Certificate No: 548k to EN 54-12: 2002
Beam Detectors
Certificated Products
I-9105R
Intelligent optical beam detector
Notes:
1) Meets the requirements of EN 54-12 at the following sensitivity settings:
Level 1 - 1.61 dB
Level 2 - 2.31 dB
LPCB Ref.
No.
548k/01
Certificate No: 548q to EN54-5: 2000 + A1:2002, EN54-7: 2000 + A1: 2006, CEA 4021: 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
C-9101
I-9101
DC-9101E
20 Oct 2014
Conventional Optical Smoke and Heat Multisensor Detector
(P-9907 Base, DZ-03D Base & DZ-03 Base)
Notes:
1. Meets the requirements of EN 54-7: 2000 at sensitivity setting Mode 1
2. Meets the requirement of EN 54-5: 2000 at Class A2R
Intelligent Optical Smoke and Heat Multisensor Detector
(DZ-03 Base)
Notes:
1. Meets the requirements of EN 54-7: 2000 at sensitivity setting Mode 1
2. Meets the requirement of EN 54-5: 2000 at Class A2R
Conventional Combination Heat/Photoelectric Smoke Detector (DB-01 & DB-01D bases
and DP-9907 Unit)
Notes:1. Meets the requirements of EN 54-7: 2000 at
sensitivity level 1 (default) setting only
LPCB Ref.
No.
548q/01
548q/02
548q/03
283
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
2. Meets the requirements of EN 54-5: 2000 for Class A2R Conventional Combination
Heat/Photoelectric Smoke Detector
Intelligent Combination Heat/Photoelectric Smoke Detector (DB-01 base)
Notes:
1. Meets the requirements of EN 54-7: 2000 at sensitivity level 1 (default) setting only
2. Meets the requirements of EN 54-5: 2000 for Class A2R
DI-9101E
Bases:
DZ-03
P-9907
DZ-03D
DB-01
DB-01D
DP-9907
LPCB Ref.
No.
548q/04
Standard base
Active EOL base
Diode Base
Standard Base
Diode Base
Active End of Line Unit
Haes Systems Limited
Columbia House, Packet Boat Lane, Cowley Peachey, Uxbridge, Middlesex UB8 2JP, United Kingdom
Tel: +44 (0)1895 422066 • Fax: +44 (0)1895 420603
E-mail: [email protected] • Website: www.haes-systems.co.uk
Certificate No: 810b to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
55000-122HSL
55000-127HSL
55000-132HSL
55000-137HSL
55000-400HSL
55000-401HSL
Series 65 Conventional Class A1R Heat Detector
(45681-200HSL mounting base)
Note:Meets the requirements of EN 54: Part 5 - Class A1R
Series 65 Conventional Class BR Heat Detector
(45681-200HSL mounting base)
Note:Meets the requirements of EN 54: Part 5 Class BR
Series 65 Conventional Class CR Heat Detector
(45681-200HSL mounting base)
Note:Meets the requirements of EN 54: Part 5 Class CR
Series 65 Conventional Class CS Heat Detector
(45681-200HSL mounting base)
Note:Meets the requirements of EN 54: Part 5 Class CS
XP95 Analogue Addressable Class A2S Heat Detector
(45681-210HSL mounting base)
XP95 Analogue Addressable Class CS High Temperature Heat Detector (45681-210HSL
mounting base)
LPCB Ref.
No.
810b/01
810b/02
810b/03
810b/04
810b/05
810b/06
Bases:
45681-200HSL Series S65 Mounting Base
45681-210HSL Series XP95 mounting base
Certificate No: 810c to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
55000-217HSL
55000-317HSL
55000-500HSL
55000-600HSL
Series 65 Conventional Ionisation Smoke Detector
(45681-200HSL mounting base)
Series 65 Conventional Optical Smoke Detector
(45681-200HSL mounting base)
XP95 Analogue Addressable Ionisation Smoke Detector
(45681-210HSL mounting base)
XP95 Analogue Addressable Optical Smoke Detector
(45681-210HSL mounting base)
LPCB Ref.
No.
810c/01
810c/02
810c/03
810c/04
Bases:
284
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
45681-200HSL Series 60/65 Mounting Base
45681-210HSL Series XP95 Mounting Base
Certificate No: 810d to EN 54-7: 2001 + A1: 2002 + A2: 2006 and CEA 4021: 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
55000-885HSL
XP95 Analogue Addressable Multisensor Detector
(45681-210HSL mounting base)
LPCB Ref.
No.
810d/01
Bases:
45681-210HSL Series XP95 Mounting Base
HDR
Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom
Tel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132
E-mail: [email protected] • Website: www.hochikieurope.com
Certificate No: 117f to EN54-7: 2000 + A1: 2002, EN54-5: 2000 + A1: 2002 and CEA 4021: 1999
Multi-Criteria Detectors
Certificated Products
1410010
Intelligent analogue addressable multisensor (YBN-R/3 base)
Note: Meets EN 54-5 class A1 and B and EN 54-7 at 3.0%/m sensitivity setting in normal
and low power mode.
LPCB Ref.
No.
117f/01
Certificate No: 117g to EN 54 Part 5: 2000
Point Heat Detectors/Sensors
Certificated Products
1215110
1215120
1217180
1217190
1410020
Class A1S conventional fixed temperature heat detector (YCA-RL/3H2M, YBN-R/6SK
and 1226150)
Class CS conventional fixed temperature heat detector (YCA-RL/3H2M, YBN-R/6SK and
1226150 bases)
Class A1R conventional rate of rise temperature heat detector (YCA-RL/3H2M, YBNR/6SK and 1226150 bases)
Conventional Class CR rate of rise high temperature heat detector (YBN-R/6SK and
1226150 bases)
Intelligent analogue addressable Class P heat detector (1426010 and 1226110 bases)
Note: Meets requirements of EN54-5: 2000 for classes A1R, A1S, BR, BS, CR and CS
when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E
protocol.
LPCB Ref.
No.
117g/02
117g/03
117g/04
117g/06
117g/09
Bases:
1226150 Standard base
1426010 Standard base
YCA-RL/3H2M Addressable base
YBN-R/6SK Schottky diode base
Certificate No: 117j to EN 54-12: 2002
Beam Detectors
Certificated Products
1213060
1213080
20 Oct 2014
Optical Beam Smoke Detector
Note: Certified at a sensitivity setting of 30% obscuration
Conventional 2 wire optical beam smoke detector
Notes:
LPCB Ref.
No.
117j/01
117j/03
285
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
1) Approved at sensitivity setting 25% and 50%.
2) Approved for use with 1213080 2WI interface kit.
Certificate No: 358c to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors/Sensors
Certificated Products
1412110
Intelligent analogue addressable optical smoke detector
(YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)
Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in
normal and low power modes
Intelligent analogue addressable optical smoke detector
(YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)
Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in
normal and low power modes
Conventional optical smoke detector
(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases)
Conventional optical smoke detector
(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases)
1412120
1212270
1212280
Bases
YBN-R/3
YBO-R/SCI
YBO-BS
YBO-BSB
YBN-R/6
YBN-R/6SK
YBO-R/6R
YBO-R/6RS
YBO-R/6RN
YBO-R/6PA
LPCB Ref.
No.
358c/03
358c/04
358c/05
358c/06
Standard base
Positive switching short circuit isolator base
Sounder base
Sounder base with Beacon
Standard base
Standard base with schottky diode
Relay base
Relay base latching with schottky diode
Relay base non latching
Protector alarms base
Hochiki America Corporation
7051 Village Drive, Buena Park, California 90621, USA
Tel: +1 714 522 2246 • Fax: +1 714 522 2268
E-mail: [email protected] • Website: www.hochiki.com
Certificate No: 358d to EN 54-10: 2002 + A1: 2005
Flame Detectors
Certificated Products
IR3
IR3-IS
IR3-EX
IR2-UV
IR2-UV-EX
3
Conventional IR Flame Detector
(IR-AMB)
Note: Meets EN 54-10: 2002 at Class 1 only
Conventional IR 3 Intrinsically Safe Flame Detector
Note: Meets EN 54-10: 2002 at Class 1 only
Conventional IR 3 (Exd) Flameproof Flame Detector
(IR-AMB)
Note: Meets EN 54-10: 2002 at Class 1 only
Conventional UV/IR² Flame Detector
(IR-AMB)
Note: Meets EN 54-10: 2002 at Class 1 only
Conventional UV/IR 2 (Exd) Flameproof Flame Detector
(IR-AMB)
Note: Meets EN 54-10: 2002 at Class 1 only
LPCB Ref.
No.
358d/01
358d/02
358d/03
358d/04
358d/05
Ancillaries
IR-AMB Adjustable Mounting Bracket
286
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 358c to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
ALK-E
ALK-E (WHT)
ALG-EN
ALG-EN (BLK)
ALG-EN (WHT)
SLV-E3
SLV-E3 (WHT)
SLR-E3N
SLR-E3N (BLK)
SLR-E3N (WHT)
ALN-EN
ALN-EN (WHT)
Intelligent Analogue Addressable Optical Smoke DetectorYBO-R/SCI, YBO-BS & YBOBSB bases)
Note:1. Meets the requirements of EN 54-7 in low and high sensitivity setting and in
normal and low power modes.
Intelligent Analogue Addressable Optical Smoke Detector (White)YBO-R/SCI, YBO-BS &
YBO-BSB bases)
Note:1. Meets the requirements of EN 54-7 in low and high sensitivity setting and in
normal and low power modes.
Intelligent Analogue Addressable Optical Smoke DetectorYBO-R/SCI, YBO-BS & YBOBSB bases)
Note:1. Meets the requirements of EN 54-7 in low and high sensitivity setting and in
normal and low power modes.
Intelligent Analogue Addressable Optical Smoke Detector (Black)YBO-R/SCI, YBO-BS &
YBO-BSB bases)
Note:1. Meets the requirements of EN 54-7 in low and high sensitivity setting and in
normal and low power modes.
Intelligent Analogue Addressable Optical Smoke Detector (White)YBO-R/SCI, YBO-BS &
YBO-BSB bases)
Note:1. Meets the requirements of EN 54-7 in low and high sensitivity setting and in
normal and low power modes.
Conventional Optical Smoke DetectorYBN-R/6SK, YBO-R/6R, YBO-R/6RS, YBO-R/6RN
& YBO-R/6PA bases)
Conventional Optical Smoke Detector (White)YBN-R/6SK, YBO-R/6R, YBO-R/6RS,
YBO-R/6RN & YBO-R/6PA bases)
Conventional Optical Smoke Detector YBN-R/6SK, YBO-R/6R, YBO-R/6RS, YBO-R/6RN
& YBO-R/6PA bases)
Conventional Optical Smoke Detector (Black)YBN-R/6SK, YBO-R/6R, YBO-R/6RS,
YBO-R/6RN & YBO-R/6PA bases)
Conventional Optical Smoke Detector (White)YBN-R/6SK, YBO-R/6R, YBO-R/6RS,
YBO-R/6RN & YBO-R/6PA bases)
Intelligent Analogue Addressable Optical Smoke DetectorYBN-R/3, YBO-R/SCI, YBO-BS
& YBO-BSB Bases)
Note:1. Meets the requirements of EN 54-7 in low and high sensitivity settings.
Intelligent Analogue Addressable Optical Smoke Detector (White)YBN-R/3, YBO-R/SCI,
YBO-BS & YBO-BSB Bases)
Note:1. Meets the requirements of EN 54-7 in low and high sensitivity settings.
LPCB Ref.
No.
358c/03
358c/03
358c/04
358c/04
358c/04
358c/05
358c/05
358c/06
358c/06
358c/06
358c/07
358c/07
Bases
YBN-R/3
YBO-R/SCI
YBO-BS
YBO-BSB
YBN-R/6
YBN-R/6SK
YBO-R/6R
YBO-R/6RS
YBO-R/6RN
YBO-R-6PA
YBN-R/3(SCI)
Standard Base
Positive switching short circuit isolator base
Sounder base
Sounder base with Beacon
Standard Base
Standard base with schottky diode
Relay Base
Relay Base latching with schottky diode
Relay base non latching
Protector alarms base
Short circuit isolator base
Hochiki Corporation
246 Tsuruma, Machidia, Tokyo 194-8577, Japan
Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167
E-mail: [email protected] • Website: www.hochiki.co.jp
Certificate No: 117k to EN 54-10: 2002 + A1: 2005
20 Oct 2014
287
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
DRD-E
Bases
YBN-R/6SK
YBN-R/6
YBO-R/6R
YBO-R/6RN
YBO-R/6PA
YBO-R/6RS
Conventional Class 1 IR Flame Detector
(YBN-R/6SK, YBN-R/6, YBO-R/6R, YBO-R/6RN, YBO-R/6PA, YBO-R/6RS)
LPCB Ref.
No.
117k/01
Conventional Schottky diode base
Conventional standard base
Conventional latching relay base
Conventional non-latching relay base
Conventional 2 wire base
Conventional latching relay base with integral Schottky diode
Hochiki Europe (UK) Limited
Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom
Tel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132
Website: www.hochikieurope.com
Certificate No: 928k-(cl-7) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008
Smoke Detectors
Certificated Products
ROD-E
Wireless optical smoke detector (RSM-WDB base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1R
2. The device must be used with the following batteries only:
CR123A (3 Vdc) - main battery
CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928k/01
Bases:
RSM-WDB - Wireless Adaptor Base
Certificate No: 928j-(cl-7) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008
Heat Detectors
Certificated Products
RHD-E
Wireless heat detector (RSM-WDB base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1R
2. The device must be used with the following batteries only:
CR123A (3 Vdc) - main battery
CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928j/01
Base:
RSM-WDB - Wireless Adaptor Base
288
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
All Enquiries to:
Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United
Kingdom
Tel: +44 (0) 1634 260131 • Fax: +44 (0) 1634 260132
Manufacturing at (Certificate Nos 117, 117f, 117g, 117h, 117j)
Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan
Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167
E-mail: [email protected] • Website: www.hochiki.co.jp
Manufacturing at (Certificate Nos 164, 164g, 164m)
Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United
Kingdom
Tel: +44 (0) 1634 260131 • Fax: +44 (0) 1634 260132
E-mail: sales @hochikieurope.com • Website: www.hochikieurope.com
Manufacturing at (Certificate Nos 358, 358c)
Hochiki America Corporation, 7051 Village Drive, Buena Park, California 90621, USA
Tel: +1 714 522 2246 • Fax: +1 714 522 2268
E-mail: [email protected] • Website: www.hochiki.com
Certificate No: 117h to EN 54-7: 2000
Certificate No: 164g to EN 54-7: 2000 + A1: 2002
Certificate No: 358c to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors/Sensors
Certificated Products
SLV-E(J)
ALK-E(J)
ALN-E(HFP)
ALN-EN
ALN-EN(WHT)
SLR-E-IS
SLK-EN
ALK-E(HFP)
ALK-EM
ALG-ENM
20 Oct 2014
1
Conventional photoelectric smoke detector (YBN-R/4C base)
Analogue addressable photoelectric smoke detector
(YBN-R/2NA,YBO-R/SCI,YBO-BS & YBO-BSB bases)
Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in
normal and low power modes
Intelligent Analogue Addressable Optical Smoke Detector
(YBN-R/3(SCI), YBN-R/3, YBO-R/SCI, YBN-R/2NA, YBO-BS & YBO-BSB bases)
Note:
Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and
low power modes
Intelligent Analogue Addressable Optical Smoke Detector
(YBN-R/3(SCI), YBN-R/3, YBO-R/SCI, YBN-R/2NA, YBO-BS & YBO-BSB bases)
Note:
Meets the requirements of EN54-7 in low and high sensitivity settings
Intelligent Analogue Addressable Optical Smoke Detector
(YBN-R/3(SCI), YBN-R/3, YBO-R/SCI, YBN-R/2NA, YBO-BS & YBO-BSB bases)
Note:
Meets the requirements of EN54-7 in low and high sensitivity settings
Conventional photoelectric smoke detector (YBN-R/4IS base)
Conventional photoelectric smoke detector (YBF-RL/4H3, YBF-RL/4H5, YBF-RL/4H5H
bases)
Intelligent analogue addressable optical smoke detector (White) (YBN-R/3(HFP),
YBO/R3SCI(HFP), YBO/BS & YBO-BSB bases)
Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in
normal and lower power modes
Intelligent analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS
& YBO-BSB bases)
Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in
normal and low power modes
Intelligent analogue addressable optical smoke detector
(YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)
Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in
normal and low power modes
LPCB Ref.
No.
117h/01
117h/02
117h/03
117h/04
117h/04
164g/02
164g/03
358c/03
358c/03
358c/04
289
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
SLV-E3
SLV-E3 (WHT)
SLV-E3(HFP)
SLR-E3N
SLR-E3N(BLK)
SLR-E3N(WHT)
Bases
YBO-R/SCI
YBO-BS
YBO-BSB
YBO-R/6R
YBO-R/6RS
YBO-R/6RN
YBO-R/6PA
YBN-R/3
YBN-R/2NA
YBN-R/6
YBN-R/6SK
YBO-BS
YBO-BSB
YBN-R/3(SCI)
YBN-R/3
Conventional optical smoke detector
(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA
bases)
Conventional optical smoke detector(White)
(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA
bases)
Conventional optical smoke detector (White)
(YBN-R/6(HFP) bases)
Conventional optical smoke detector
(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA
bases)
Conventional optical smoke detector(Black)
(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA
bases)
Conventional optical smoke detector(White)
(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA
bases)
LPCB Ref.
No.
358c/05
358c/05
358c/05
358c/06
358c/06
358c/06
Positive switching short circuit isolator base
Sounder base
Sounder base with Beacon
Relay base
Relay base latching with schottky diode
Relay base non latching
Protector alarms base
Standard base
Standard base
Standard base
Standard base with schottlky diode
Sounder base
Sounder base with Beacon
Short Circuit Isolator Base
Addressable detector base
All Enquiries to:
Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United
Kingdom
Tel: +44 (0)1634 260131 • Fax: +44 (0)1634 260132
Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j)
Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan
Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167
E-mail: [email protected] • Website: www.hochiki.co.jp
Manufacturing at (Certificate Nos. 164, 164g, 164m)
Hochiki Europe (UK) Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United
Kingdom
Tel: +44 (01634 260131 • Fax: +44 (0)1634 260132
E-mail: [email protected] • Website: www.hochikieurope.com
Manufacturing at (Certificate Nos. 358, 358c)
Hochiki America Corporation, 7051 Village Drive, Buena Park, California 90621, USA
Tel: +1 714 522 2246 • Fax: +1 714 522 2268
E-mail: [email protected] • Website: www.hochiki.com
Certificate No: 117g to EN 54 Part 5: 2000
290
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Point Heat Detectors/Sensors
Certificated Products
DCD-1E-IS
DFJ-AE3
DFJ-AE3 (HFP)
DFJ-CE3
DFJ-CE3 (HFP)
DCD-AE3
DCD-AE3 (HFP)
DCD-AE3M
DFG-60BLKJ
DCD-CE3
DCD-CE3(HFP)
DCD-CE3M
ACB-E
ACB-E (HFP)
ACB-EW
ATJ-E
ATJ-E(HFP)
ATJ-E(WHT)
ATJ-EN
ATJ-EN(WHT)
Bases:
YBN-R/4IS
YCA-RL/3H2M
YBN-R/6SK
YBN-R/6
YBN-R/3
YBO-R/SCI
YBO-RSCI/NS
YBF-RL/4H3H
YBF-RL/4H5H
YBN-R/6M
YBO-BSB
20 Oct 2014
Class A1 conventional intrinsically safe fixed temperature and rate of rise heat detector
(YBN-R/4IS1 base)
Class A1S conventional fixed temperature heat detector
(YCA-RL/3H2M 1 , YBN-R6 SK 1 , YBN-R/6 1 YBO-R/6R, YBO-R/6RS, YBO-R/6RN and
YBO-R/6PA bases)
Class A1S conventional fixed temperature heat detector (YBN-R/6(HFP) base)
Class CS conventional fixed temperature heat detector
(YCA-RL/3H2M 1 , YBN-R6 SK 1 , YBN-R/6 1 YBO-R/6R, YBO-R/6RS, YBO-R/6RN and
YBO-R/6PA bases)
Class CS conventional fixed temperature heat detector (YBN-R/6(HFP)base)
Class A1R conventional rate of rise temperature heat detector
(YCA-RL/3H2M 1 , YBN-R6 SK 1 , YBN-R/6 1 YBO-R/6R, YBO-R/6RS, YBO-R/6RN and
YBO-R/6PA bases)
Class A1R conventional rate of rise temperature heat detector (YBN-R/6 (HFP)base)
Conventional Class A1R rate of rise temperature heat detector
(YBN-R/6M base)
Class A2 conventional fixed temperature water resistant heat detector
CDX Class CR conventional rate of rise high temperature heat detector
(YCA-RL/3H2M 1 , YBN-R6 SK 1 , YBN-R/6 1 YBO-R/6R, YBO-R/6RS, YBO-R/6RN and
YBO-R/6PA bases)
Class CR conventional rate of rise high temperature heat detector (YBN-R/6(HFP)base)
Conventional Class CR rate of rise high temperature heat detector
(YBN-R/6M base)
Intelligent Analogue addressable Class P heat detector
(YBN-R/3 1 and YBO-R/SCI 1 bases)
Note:
Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when
used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol.
Intelligent analogue addressable Class P heat detector (YBN-R/3(HFP) and YBOR/SCI(HFP) bases).
Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when
used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol.
Weather proof Intelligent Analogue addressable Class P heat detector
Note:
Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when
used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol.
Intelligent Analogue addressable Class P heat detector
(YBN-R/3 1 , YBN-R/3(SCI) 1 ,YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases)
Note:
Meets requirements of EN 54-5:2000 for classes A1R, BR and CR.
Intelligent Analogue addressable Class P heat detector
(YBN-R/3 1 , YBN-R/3(SCI) 1 , YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases)
Note:
Meets requirements of EN 54-5:2000 for classes
A1R, BR, CR, A1S, BS and CS.
Intelligent Analogue addressable Class P heat detector
(YBN-R/3 1 , YBN-R/3(SCI) 1 ,YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases)
Note:
Meets requirements of EN 54-5:2000 for classes A1R, BR, CR, A1S, BS and CS.
Intelligent Analogue addressable Class P heat detector
(YBN-R/3 1 , YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases)
Note:
Meets requirements of EN 54-5:2000 for classes A1R, BR CR, A1S, BS and CS.
Intelligent Analogue addressable Class P heat detector
(YBN-R/3 1 , YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases)
Note:
Meets requirements of EN 54-5:2000 for classes A1R, BR, CR, A1S, BS and CS.
LPCB Ref.
No.
117g/01
117g/02
117g/02
117g/03
117g/03
117g/04
117g/04
117g/04
117g/05
117g/06
117g/06
117g/06
117g/09
117g/09
117g/10
117g/13
117g/13
117g/13
117g/14
117g/14
Conventional Intrinsically Safe Mounting base
Addressable base
Schottky diode base
Standard base
Standard base
Positive Switching Short circuit isolating base
Negative Switching Short circuit isolating base
2 wire common mounting base
2 wire common mounting base
Standard Base
Base sounder beacon
291
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
YBO-BS
YBO-R/6PA
YBO-R/6R
YBO-R/6RS
YBO-R/6RN
YBN-R/3(SCI)
Base sounder
Protector alarms base
Relay base
Relay latching base with Schottky diode
Relay base non-latching
Short circuit Isolating base
All Enquiries to:
Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United
Kingdom
Tel: +44 (0)1634 260131 • Fax: +44 (0)1634 260132
Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j)
Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan
Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167
Certificate No: 117f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 and CEA 4021: 1999
Certificate No: 928m-(cl-7) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003
Multi-criteria Detectors
Certificated Products
ACA-E
ACA-E (HFP)
ACC-E
ACC-E(HFP)
ACC-E(WHT)
ACC-EN
ACC-EN(WHT)
RMD-E
292
Intelligent Analogue addressable multisensor (YBN-R/3 base)
Note:
Meets EN 54-5 class A1 and B and EN 54: Part 7 at 3.0%/m sensitivity setting in normal
and low power mode.
Intelligent analogue addressable multisensor (YBN-R/3(HFP) base)
Note:
Meets EN 54-5 class A1 and B and EN 54: Part 7 at 3.0%/m sensitivity setting in normal
and low power mode.
Intelligent Analogue addressable multi-criteria detector
(YBN-R/31, YBO-R/SCI1, YBO-BS1, YBO-BSB1 and YBN-R/3(SCI) bases)
Note:
Certificated at the following modes:
Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity
Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity
Mode 2 - Fixed temperature heat detector at class A1 & C
Intelligent Analogue addressable multi-criteria detector
(YBN-R/3(HFP), YBO-R/SCI, YBO-BS and YBO-BSB bases)
Note:
Certificated at the following modes:
Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity
Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity
Mode 2 - Fixed temperature heat detector at class A1 & C
Intelligent Analogue addressable multi-criteria detector
(YBN-R/31, YBO-R/SCI1, YBO-BS1, YBO-BSB1 and YBN-R/3(SCI) bases)
Note:
Certificated at the following modes:
Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity
Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity
Mode 2 - Fixed temperature heat detector at class A1 & C
Intelligent Analogue addressable multi-criteria detector
(YBN-R/3, YBO-R/SCI, YBO-BS, YBO-BSB and YBN-R/3(SCI) bases)
Note: Certificated at the following modes:
Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity
Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity
Mode 2 - Fixed temperature heat detector at class A1 & C
Intelligent Analogue addressable multi-criteria detector
(YBN-R/3, YBO-R/SCI, YBO-BS, YBO-BSB and YBN-R/3(SCI) bases)
Note:Certificated at the following modes:
Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivity
Mode 1 - Optical smoke detector at 2% and 4.5% sensitivity
Mode 2 - Fixed temperature heat detector at class A1 & C
Wireless multi-criteria detector (RSM-WDB base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1
2. Meets the requirements of EN 54-7 in the normal sensitivity setting
LPCB Ref.
No.
117f/01
117f/01
117f/02
117f/02
117f/02
117f/03
117f/03
928m/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
3.
The device must be used with the following batteries only:
CR123A (3 Vdc) - main battery
CR2032A (3 Vdc) - secondary battery
Bases:
YBN-R/3 base
YBN-R/3 Standard base
YBN-R/2NA base
YBO-R/SCI Positive switching short circuit isolator base
YBN-R/4IS intrinsically safe mounting base1
YCA-RL/3H2 addressable base
YCA-RL/5H2 master addressable base
AMU-B2 addressable base
AMU-MB master addressable base
YBC-RL/4H5 base
YBF-RL/3J slave base
YBF-RL/4H5 base1
YBK-RL/4H1A base1
YBK-RL/4H2 base1
YCA-RL/3H2M addressable base
YBN-R/6SK Schottky diode base
YBN-R/6 Standard base
YBN-R/4 base1
YBN-R/6M Standard base
YBO-BS Sounder base
YBO-BSB Sounder base with Beacon
YBO-R/5 base1
YBN-R/4M base1
YBO-R/5M base1
YBO-R/6R Relay base
YBO-R/6RS Relay base latching with schottky diode
YBO-R/6RN Relay base non latching
YBO-R/6PA Protector alarms base
YBO-RSCI/NS Negative Switching Short circuit isolating base
YBF-RL/4H3H 2 wire mounting base
YBF-RL/4H5H 2 wire mounting base
RSM-WDB - Wireless Adaptor Base
YBN-R/3(SCI) Short circuit isolator base
1
Bases manufactured by Hochiki Europe. All other bases manufactured by Hochiki Corporation.
denotes detector/base combination is approved in low power mode also.
LP
All Enquiries to:
Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United
Kingdom
Tel: +44 (0)1634 260131 • Fax: +44 (0)1634 260132
Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j)
Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan
Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167
Certificate No: 117j to EN 54-12: 2002
Beam Detectors
Certificated Products
SRA-ET
SRA-ET (HFP)
SPC-E
20 Oct 2014
Optical Beam Smoke Detector
Note:
1) Certified at sensitivity settings 30% obscuration
Optical Beam Smoke Detector
Note:
1) Certified at sensitivity settings 30% obscuration
Conventional 4 wire optical beam smoke detector
Notes:
LPCB Ref.
No.
117j/01
117j/01
117j/02
293
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
SPC-ET
SPC-ET(HFP)
LPCB Ref.
No.
1) Approved at sensitivity setting 25% and 50%
Conventional 2 wire optical beam smoke detector
Notes:
1) Approved at sensitivity setting 25% and 50%
2) Approved for use with SPC-ET2WI interface kit
Conventional 2 wire optical bem smoke detector.
Notes:
1) Approved at sensitivity setting 25% and 50%
2) Approved for use with SPC-ET2WI interface kit
117j/03
117j/03
All Enquiries to:
Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United
Kingdom
Tel: +44 (0) 1634 260131 • Fax: +44 (0) 1634 260132
Manufacturing at (Certificate Nos 164, 164g, 164m)
Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United
Kingdom
Tel: +44 (0) 1634 260131 • Fax: +44 (0) 1634 260132
E-mail: [email protected] • Website: www.hochikieurope.com
Certificate No: 164m to EN54-10:2002
Flame Detectors
Certificated Products
IFD-E
IFD-E(IS)
IFD-E(EXD)
LPCB Ref.
No.
164m/01
Conventional IR 3 Flame detector (IFD-MB)
Note: Meets EN 54-10: 2002 at Class 1 only
Conventional IR 3 Intrinsically Safe Flame Detector (IFD-MB)
Note: Meets EN 54-10: 2002 at Class 1 only
Conventional IR 3 (Exd) Flameproof Flame Detector (IFD-MB)
Note: Meets EN 54-10: 2002 at Class 1 only
164m/02
164m/03
Honeywell Automation (I) Pvt. Ltd
53, 54, 55 Hadapasar Indl. Estate, Hadapsar, Pune-411013, India
Tel: +91 020 66780200 • Fax: +91 020 66780172
E-mail: [email protected] • Website: www.honeywell.com
Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003
Certificate No: 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003
Multi-criteria Detectors
Certificated Products
TC840MES-yy
TC840MEIS-yy
294
Analogue addressable photo-thermal multi-criteria detector (B501AP, B501, B524IEFT-1,
B524HTR and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria smoke detector with short circuit
isolator (B501AP, B524HTR and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
LPCB Ref.
No.
550b/05
550e/02
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Bases:
1450614-007 Standard analogue detector base
B501 standard analogue detector base
B501AP intelligent detector base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
Certificate No: 550c to EN54-5: 2000 + A1: 2002
Certificate No: 550f to EN54-5: 2000 + A1: 2002 and EN 54-17: 2005
Point Heat Detectors
Certificated Products
TC808ES1028-yy
TC808ES1002-yy
TC808EIS1028-yy
TC808EIS1002-yy
Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1,
B524HTR and B524RTE bases)
Note:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Analogue addressable class A1S fixed temperature heat detector (B501AP, B501,
B524IEFT-1, B524HTR and B524RTE bases)
Note:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Analogue addressable class A1R rate of rise heat detector with short circuit isolator
(B501AP, B524HTR and B524RTE bases)
Note:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Analogue addressable class A1S fixed temperature heat detector with short circuit
isolator (B501AP, B524HTR and B524RTE bases)
Note:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
LPCB Ref.
No.
550c/06
550c/07
550f/01
550f/02
Bases:
14506414-007 Standard analogue detector base
B501 standard analogue detector base
B501AP intelligent detector base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
Certificate No: 550a to EN54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 550d to EN54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Point Smoke Detectors
Certificated Products
TC806ES1012-yy
TC806EIS1012-yy
Analogue addressable optical smoke detector
(B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity
Analogue addressable optical smoke detector with short circuit isolator
(B501AP, B524HTR and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity
LPCB Ref.
No.
550a/04
550d/01
Bases:
14506414-007 standard analogue detector base
B501 standard analogue detector base
B501AP intelligent detector base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
20 Oct 2014
295
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Honeywell Control Systems Limited
Honeywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United Kingdom
Tel: +44 (0)1344 655609 • Fax: +44 (0)1344 655474
Website: www.honeywell.com
Certificate No: 199p-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002 and CEA 4021: 2003
Certificate No: 199aa-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005
Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005
Certificate No: 199t-(cl-1) to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021:
2003
Multi-criteria Detectors
Certificated Products
TC840MFEIS
TC840MEIS
TC840MFES
TC840MES
TC850E1009-yy
Analogue addressable photo-thermal-IR multi-criteria smoke sensor
with short circuit isolator (B501AP, B524HTR & B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000
& CEA 4021: 2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit
isolator (B501AP, B524HTR & B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000
& CEA 4021: 2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal-IR multi-criteria sensor
(B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000
& CEA 4021: 2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria sensor
(B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000
& CEA 4021: 2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal
and IR sensors (B501, B501DG and B524IEFT-1 bases)
Notes:
1.) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
LPCB Ref.
No.
199aa/01
199aa/02
199p/06
199p/07
199t/01
2.) Certified at the following settings: Normal Mode:
Alarm Levels 1 to 5 (Multi-criteria):
LPS1279 and CEA 4021
Alarm Level 6 (Heat Only Mode):
Nuisance Environment Applications:
Application 0,Alarm Level 4
Application 1,Alarm Level 5
Application 2,Alarm Level 4 or 5
Application 3,Alarm Level 5
Application 4,Alarm Level 5
Application 5,Alarm Level 5
Application 6,Alarm Level 5
Application 7,Alarm Level 5
296
EN54-5 Class A1R, EN54-7,
EN54-5 Class A1R
LPS1279 & CEA 4021
EN54-5 Class A1R, EN54-7
& CEA 4021
EN54-5 Class A1R, EN54-7
& CEA 4021
EN54-5 Class A1R, EN54-7
& CEA 4021
EN54-5 Class A1R, EN54-7
& CEA 4021
EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7
& CEA 4021
EN54-5 Class A1R, LPS1279
& CEA 4021
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Bases:
B501
B501AP
B524IEFT-1
B524HTR
B524RTE
standard analogue detector base
intelligent detector base
analogue short circuit isolator base
heater base
latching relay base
Certificate No: 199w to EN 54-12: 2002 & EN 54-17: 2005
Beam Detectors
Certificated Products
TC847A1004EURIS
Ancillaries:
RTS151-KEY
6500 - LRK/BEAMLRK
6500 - MMK/BEAMMMK
6500 - SMK/BEAMSMK
Analogue optical beam detector with self test facility and short circuit isolator feature
Note:
1. Meets the requirements of BS EN54-12: 2002 at sensitivity levels 1, 2, 3, 4 and
Acclimate levels 1 & 2
LPCB Ref.
No.
199w/02
Remote test Station
Long Range Kit
Multi-Mounting Kit
Surface Mounting Kit
Certificate No: 199n to EN 54-5: 2000 + A1: 2002
Certificate No: 199n-(cl-1) to EN 54-5: 2000 + A1: 2002
Certificate No: 199ac-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005
Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005
Point Heat Detectors
Certificated Products
TC808EIS1002
TC808EIS1051
TC808EIS1028
TC808ES1028
TC808ES1051
TC808ES1002
Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator
(B501AP, B524HTR & B524RTE bases)
Analogue addressable class BS fixed temperature heat sensor with short circuit isolator
(B501AP, B524HTR & B524RTE bases)
Analogue addressable class A1R rate of rise heat sensor with short circuit isolator
(B501AP, B524HTR & B524RTE bases)
Analogue addressable class A1R rate of rise heat sensor
(B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)
Analogue addressable class BS fixed temperature heat sensor
(B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)
Analogue addressable class A1S fixed temperature heat sensor
(B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)
LPCB Ref.
No.
199ac/01
199ac/02
199ac/03
199n/15
199n/16
199n/17
Bases:
SIGI-IBS Isolator base
SIGA-SB Standard base
SIGA-SB4 Standard base with trim skirt
SIGA-RB Relay base
B501 analogue detector base
B501AP intelligent sensor base
B501DG analogue deep base
B524IEFT analogue short circuit isolator base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
Certificate No: 199m to EN 54-7: 2000 + A1: 2002
Certificate No: 118h to EN 54-7: 2000
Certificate No: 199m-(cl-1) to EN 54-7: 2000 + A1: 2002
Certificate No: 199ab-(cl-1) to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005
Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005
Point Smoke Detectors/Sensors
Certificated Products
TC846A1005
20 Oct 2014
Analogue addressable laser optical detector (B501, B501DG & B524IEFT bases)
LPCB Ref.
No.
118h/01
297
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
TC806EIS1012
TC842B1007 AE
TC806ES1012
LPCB Ref.
No.
Note: meets requirements of EN 54 Part 7 at sensitivity settings of 7 to 9 inclusive
Analogue addressable optical smoke sensor with short circuit isolator (B501AP,
B524HTR & B524RTE bases)
Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity
Intrinsically safe analogue addressable photoelectric smoke detector (B501, B501AP
bases)
Note: Meets EN54-7: 2000 at High, Normal & Low sensitivity settings
Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR &
B524RTE bases)
Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity
199ab/01
199m/07
199m/10
Bases:
B501 Analogue detector base
B501DG Analogue deep base
B501AP Intelligent detector base
B524IEFT Analogue short circuit isolator base
B524IEFT-1 Analogue short circuit isolator base
B524HTR Heater Base
B524RTE Latching relay base
SIGI-IBS Isolator base
SIGA-SB Standard Base
SIGA-SB4 Standard base with trim skirt
SIGA-RB Relay base
SIGA-RB4 Relay base with trim skirt
Honeywell Control Systems Ltd
Honeywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United Kingdom
Tel: 01344 655609 • Fax: 01344 655474
Website: www.honeywell.com
Certificate No: 262s-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA 4021: 2003
Certificate No: 262t-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
XLS-IPHSI
XLS-PHSI
XLS-ISI
XLS-PSI
298
Intelligent analogue addressable thermally enhanced photoelectric and ionisation smoke
detector
(SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,
SIGA-IB, SIGA-IB4 & SIGA-AB4G bases)
Notes:
1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft,
3%/ft, and 3.5%/ft.
2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases.
Intelligent analogue addressable thermally enhanced photoelectric smoke detector
(SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,
SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)
Notes:
1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft,
3%/ft, and 3.5%/ft.
2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases.
Intelligent analogue addressable ionisation smoke detector
SIGA-SB, SIGA-SB4,
SIGA-RB, SIGA-RB4,
SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)
Notes:
1. Meets the requirements of EN 54-7:2000 at sensitivity
settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft.
2. The SIGA-LED indicator is approved for use with
the SIGA-SB and SIGA-SB4 bases
Intelligent analogue addressable photoelectric smoke detector
SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,
SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)
Notes:
1. Meets the requirements of EN 54-7:2000 at sensitivity
settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft.
2. The SIGA-LED indicator is approved for use with
LPCB Ref.
No.
262s/01
262s/02
262t/01
262t/02
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
the SIGA-SB and SIGA-SB4 bases
Bases:
SIGI-IBS
SIGA-SB
SIGA-SB4
SIGA-RB
SIGA-RB4
SIGA-IB
SIGA-IB4
SIGA-AB4G
Isolator base
Standard base
Standard base with trim skirt
Relay base
Relay base with trim skirt
Isolator Base
Isolator base with 4 inch mounting adaptors
Sounder base
Accessories:
SIGA-LED
Indicator
Certificate No: 262u-(cl-2) to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
XLS-HRSI
Bases:
SIGI-IBS
SIGA-SB
SIGA -SB4
SIGA -RB
SIGA -RB4
SIGA-IB
SIGA-IB4
SIGA-AB4G
Intelligent analogue addressable Class A1 & A2R rate of rise heat detector
(SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB,
SIGA-IB4 and SIGA-AB4G bases)
Notes:
1. The SIGA-LED indicator is also approved for use with
the SIGA-SB and SIGA-SB4 bases
LPCB Ref.
No.
262u/02
Isolator base
Standard base
Standard base with trim skirt
Relay base
Relay base with trim skirt
Isolator Base
Isolator base with 4 inch mounting adaptors
Sounder base
Accessories:
SIGA-LED Indicator
Honeywell Life Safety Systems (Novar Systems Ltd)
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom
Tel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300
E-mail: [email protected] • Website: www.gent.co.uk
Certificate No: 524c-(cl-1) to EN 54-20:2006
Aspirating Smoke Detectors
Certificated Products
LPCB Ref.
No.
524c/01
ALL-SPEC ASD
Notes:
1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be
supplied with power from a power supply conforming to the requirements of EN
54-4.

System design, installation and commissioning shall be performed in
accordance with the manufacturer’s installation guide, associated manuals and
design software TF-SC-1 HW.

The detector shall be installed with sampling pipe conforming to EN 61386-1,
to at least Class 1131.
2. Approved detector configurations (Class A, Class B and Class C):

ALL-SPECx (standard version, no bargraph display, 1 alarm, not available for
networking)

ALL-SPECx-FR (deep freeze version, no bargraph display, 1 alarm, not
20 Oct 2014
299
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
available for networking )
ALL-SPECx-SL (silent version, no bargraph display, 1 alarm, not available for
networking)
X=detector 1 or 2
The approved detector must incorporate one or two of the following detector
modules:

ASD-TP-001-L (standard version, sensitivity of 0.015%/m)

ASD -TP-001-L-F (deep freeze version, sensitivity of 0.015%/m)

ASD -TP-01-L (standard version, sensitivity of 0.10%/m)

ASD -TP-01-L-F (deep freeze version, sensitivity of 0.10%/m)

ASD -TP-05-L (standard version, sensitivity of 0.50%/m)

ASD -TP-05-L-F (deep freeze version, sensitivity of 0.50%/m)
X=detector 1 or 2

3.
HI-SPEC ASD
524c/03
Notes:
1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be
supplied with power from a power supply conforming to the requirements of EN
54-4.

System design, installation and commissioning shall be performed in
accordance with the manufacturer’s installation guide, associated manuals and
design software TF-SC-1 HW.

The detector shall be installed with sampling pipe conforming to EN 61386-1,
to at least Class 1131.
2. Approved detector configurations (Class A, Class B and Class C):

HI-SPECx (standard version, bargraph display, 3 alarms, prepared for
networking)

HI-SPECx-FR (deep freeze version, bargraph display, 3 alarms, prepared for
networking)

HI-SPECx -SL (silent version, bargraph display, 3 alarms, prepared for
networking)
3. The approved detector must incorporate one or two of the following detector
modules:

ASD-TT-001-L (standard version, sensitivity of 0.015%/m)

ASD -TT-001-L-F (deep freeze version, sensitivity of 0.015%/m)

ASD -TT-01-L (standard version, sensitivity of 0.10%/m)

ASD -TT-01-L-F (deep freeze version, sensitivity of 0.10%/m)

ASD -TT-05-L (standard version, sensitivity of 0.50%/m)

ASD -TT-05-L-F (deep freeze version, sensitivity of 0.50%/m)
COMPACT ASD
524c/04
Notes:
1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be
supplied with power from a power supply conforming to the requirements of EN
54-4.

System design, installation and commissioning shall be performed in
accordance with the manufacturer’s installation guide, associated manuals and
design software TF-SC-1 HW.

The detector shall be installed with sampling pipe conforming to EN 61386-1,
to at least Class 1131.
2. Approved detector configurations, sensitivity of 0.50%/m (Class A, Class B and
Class C):

ASD-CM (version with 2 stages of alarm)

ASD-CM2 (version with 2 stages of alarm, ROOM IDENT)
Horing LIH Industrial Co Ltd
No. 17-6, Ai-Chien Road, Hu-Hsi Village, Yuan-Shan Hsiang (264), Ilan Hsien, Taiwan ROC
Tel: +886 2 22487599 • Fax: +886 2 22407752
Certificate No: 506a to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
AHS-871
300
Conventional photoelectric smoke detector (AHMB-L mounting base)
LPCB Ref.
No.
506a/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
AH-0311-2
AH-0311-3
AH-0311-4
Q01-2
Q01-3
Q01-4
(2 wire) Conventional photoelectric smoke detector (AHMB-031 Base)
(3 wire) Conventional photoelectric smoke detector (AHMB-031 Base)
(4 wire) Conventional photoelectric smoke detector (AHMB-031 Base)
Conventional 2-wire optical smoke detector
(AHMB-061-2 and AHMB-071-2 bases )
Conventional 3-wire optical smoke detector with remote
(AHMB-061-3 and AHMB-071-3 bases )
Conventional 4-wire optical smoke detector with relay output
(AHMB-061-4 and AHMB-071-4 bases)
LPCB Ref.
No.
506a/02
506a/03
506a/04
506a/05
506a/06
506a/07
Bases:
AHMB-031 mounting base
AHMB-L mounting base
AHMB-061-2 Standard base
AHMB-061-3 Standard base
AHMB-061-4 Standard base
AHMB-071-2 Base Unit
AHMB-071-3 Base Unit
AHMB-071-4 base Unit
Certificate No: 506b to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002 and CEA 4021: 2003
Multi-criteria Detectors
Certificated Products
AH-0315-2
AH-0315-3
AH-0315-4
Q05-2
Q05-3
Q05-4
(2 wire) Optical smoke and class A2 heat detector (AHMB-031 Base)
(3 wire) Optical smoke and class A2 heat detector (AHMB-031 Base)
(4 wire) Optical smoke and class A2 heat detector (AHMB-031 Base)
Conventional 2-wire optical smoke and class A2 heat detector
(AHMB-061-2 and AHMB-071-2 bases)
Conventional 3-wire optical smoke and class A2 heat detector with remote LED (AHMB061-3 and AHMB-071-3 bases)
Conventional 4-wire optical smoke and class A2 heat detector with relay output (AHMB061-4 and AHMB-071-4 bases)
LPCB Ref.
No.
506b/01
506b/02
506b/03
506b/04
506b/05
506b/06
Bases:
AHMB-031 mounting base
AHMB-061-2 Standard base
AHMB-061-3 Standard base
AHMB-061-4 Standard base
AHMB-071-2 Base Unit
AHMB-071-3 Base Unit
AHMB-071-4 base Unit
Certificate No: 506c to EN 54-5: 2000 + A1: 2002
Point Heat Detector
Certificated Products
AH-0316-2
AH-0316-3
AH-0316-4
Q06-2
Q06-3
Q06-4
(2 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB031 Base)
(3 wire) Conventional three wire rate of rise and fixed temperature heat detector (AHMB031 Base)
(4 wire) Conventional four wire rate of rise and fixed temperature heat detector (AHMB031 Base)
Conventional 2-wire Class A2 heat detector
(AHMB-061-2 and AHMB-071-2 bases)
Conventional 3-wire Class A2 heat detector with remote LED
(AHMB-061-3 and AHMB-071-3 bases)
Conventional 4-wire Class A2 heat detector with relay output
(AHMB-061-4 and AHMB-071-4 bases)
LPCB Ref.
No.
506c/01
506c/02
506c/03
506c/04
506c/05
506c/06
Bases:
AHMB-031 mounting base
AHMB-061-2 Standard base
AHMB-061-3 Standard base
20 Oct 2014
301
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
AHMB-061-4 Standard base
AHMB-071-2 Base Unit
AHMB-071-3 Base Unit
AHMB-071-4 base Unit
Certificate No: 506f to EN 14604: 2005
Smoke Detectors
Certificated Products
NQ9S
LPCB Ref.
No.
506f/01
Single Station Smoke Detector
INIM Electronics s.r.l.
Via Fosso Antico - Loc, Centobuchi, 63033 Monteprandone (AP), Italy
Tel: +39 0735 705007 • Fax: +39 0735 704912
E-mail: [email protected] • Website: www.inim.biz
Certificate No: 991d to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Certificate No: 991c to EN 54-7: 2000 + A1:2002 + A2:2006
Smoke Detectors
Certificated Products
ID100
ED100
LPCB Ref.
No.
991c/01
Conventional optical smoke detector
(EB0010 and EB0020 bases).
Note:
1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities.
Intelligent analogue addressable optical smoke detector with short circuit isolator
(EB0010 and EB0020 bases).
Note:
1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities.
991d/01
Bases:
EB0010 Standard base
EB0020 Relay base
Certificate No: 991f to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005
Certificate No: 991e to EN 54-5: 2000 + A1:2002
Heat Detectors
Certificated Products
ID200
ED200
Conventional class P heat detector
(EB0010 and EB0020 bases).
Note:
1) Meets the requirements of EN54-5:2000 at class A1R & class B.
Intelligent analogue addressable class P heat detector with short circuit isolator (EB0010
and EB0020 bases).
Note:
1) Meets the requirements of EN54-5:2000 at class A1R & class B.
LPCB Ref.
No.
991e/01
991f/01
Bases:
EB0010 Standard base
EB0020 Relay base
Certificate No: 991b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003 and EN 54-17: 2005
Certificate No: 991a to EN 54-5: 2000 + A1:2002, EN 54-7: 2000 + A1:2002 + A2:2006 and CEA4021: 2003
302
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Multi-Criteria Detectors
Certificated Products
ID300
ED300
Conventional multi-criteria detector (EB0010 and EB0020 bases).
Note:
1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities.
2) Meets the requirements of EN 54-5:2000 at class A1R & class B.
Intelligent analogue addressable multi-criteria detector with short circuit isolator (EB0010
and EB0020 bases).
Note:
1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities.
2) Meets the requirements of EN 54-5:2000 at class A1R & class B.
LPCB Ref.
No.
991a/01
991b/01
Bases:
EB0010 Standard base
EB0020 Relay base
Intelligent Safety & Security Technology Ltd.
6-7 Ludgate Square,, London EC4M 7AS, United Kingdom
Tel: +44 845 116 2945
E-mail: [email protected] • Website: www.isst-uk.com
Certificate No: 512a-(cl-6) to EN54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
CS-01
Conventional 2 wire photoelectric smoke detector with remote LED output (CB-D2 base)
LPCB Ref.
No.
512a/02
Base:
CB-D2 4-wire detector base
Certificate No: 512b-(cl-3) to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA4021: 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
CSH-01
Conventional 2 wire photoelectric smoke and heat detector with remote LED output (CBD2 base)
LPCB Ref.
No.
512b/02
Base:
CB-D2 4-wire detector base
Certificate No: 512d-(cl-6) to EN54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
CH-01
Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
with LED output (CB-D2 base)
LPCB Ref.
No.
512d/04
Base:
CB-D2 4-wire detector base
20 Oct 2014
303
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Kidde Products Ltd
Thame Park Road, Thame, Oxfordshire OX9 3RT, United Kingdom
Tel: +44 (0)1844 265003 • Fax: +44 (0)1844 265156
E-mail: [email protected] • Website: www.kfp.co.uk
Certificate No: 404c to EN54-20: 2006
Aspirating Smoke Detectors
Certificated Products
Senator 25
Senator 100
Senator 200
Senator 200
Senator 200
High sensitivity aspirating smoke detector
Notes:
1)
For compliance with Clause 5.10 of EN54-20:2006, the detector shall be
supplied with power from a power supply complying with EN54-4.
2)
The approval of the detector is conditional upon the following requirements:
- Design, installation and commissioning are performed in accordance with the
system design manual and instructions.
- The device is approved for sensitivity Classes A, B and C for sensitivities up
to 0.31%/m. The Class of any pipe/hole configuration and detector sensitivity
must be determined using PipeCAD.
High sensitivity aspirating smoke detector
Notes:
1)
For compliance with Clause 5.10 of EN54-20:2006, the detector shall be
supplied with power from a power supply complying with EN54-4.
2)
The approval of the detector is conditional upon the following requirements:
- Design, installation and commissioning are performed in accordance with the
system design manual and instructions.
- The device is approved for sensitivity Classes A, B and C for sensitivities up
to 0.62%/m. The Class of any pipe/hole configuration and detector sensitivity
must be determined using PipeCAD.
High sensitivity aspirating smoke standard detector (Senator 200 Stand Alone Command
Module Ancillary)
Notes:
1)
For compliance with Clause 5.10 of EN54-20:2006, the detector shall be
supplied with power from a power supply complying with EN54-4.
2)
The approval of the detector is conditional upon the following requirements:
- Design, installation and commissioning are performed in accordance with the
system design manual and instructions.
- The device is approved for sensitivity Classes A, B and C for sensitivities up
to 0.62%/m, 1.95%/m and 4.65%/m respectively. The Class of any pipe/hole
configuration and detector sensitivity must be determined using PipeCAD.
High sensitivity aspirating smoke command module detector
Notes:
1)
For compliance with Clause 5.10 of EN54-20:2006, the detector shall be
supplied with power from a power supply complying with EN54-4.
2)
The approval of the detector is conditional upon the following requirements:
- Design, installation and commissioning are performed in accordance with the
system design manual and instructions.
- The device is approved for sensitivity Classes A, B and C for sensitivities up
to 0.62%/m, 1.95%/m and 4.65%/m respectively. The Class of any pipe/hole
configuration and detector sensitivity must be determined using PipeCAD.
High sensitivity aspirating minimum display version smoke detector (Senator 200 Stand
Alone Command Module Ancillary)
Notes:
1)
For compliance with Clause 5.10 of EN54-20:2006, the detector shall be
supplied with power from a power supply complying with EN54-4.
2)
The approval of the detector is conditional upon the following requirements:
- Design, installation and commissioning are performed in accordance with the
system design manual and instructions.
- The device is approved for sensitivity Classes A, B and C for sensitivities up
to 0.62%/m, 1.95%/m and 4.65%/m respectively. The Class of any pipe/hole
configuration and detector sensitivity must be determined using PipeCAD.
LPCB Ref.
No.
404c/01
404c/02
404c/03
404c/04
404c/05
Ancillaries:
Senator 200 Stand Alone Command Module
304
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Kidde Products Ltd, trading as AirSense Technology
Unit 2, Dawdon Business Park, Blair Way, Seaham, Country Durham SR7 7PP, United Kingdom
Tel: +44(0)191-513 6100 • Fax: +44(0)191-513 6102
E-mail: [email protected] • Website: www.kfp.co.uk
Certificate No: 404c to EN 54-20: 2006
Certificated Products
Senator Nano
High sensitivity aspirating smoke detector
Notes:
1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied
with power from a power supply complying with EN 54-4.
2. The approval of the detector is conditional upon the following requirements:
Design, installation and commissioning are performed in accordance with the system
design manual and instructions.
3. The device is approved for sensitivity Classes A, B and C for sensitivities up to
0.80%/m, 1.66%/m and 7.54%/m respectively.
The Class of any pipe/hole configuration and detector sensitivity must be determined
using PipeCAD.
LPCB Ref.
No.
404c/06
Certificate No: 404c to EN54-20: 2006
Certificated Products
Stratos Micra 25
Stratos Micra 100
Stratos HSSD 2
Stratos HSSD 2
20 Oct 2014
High sensitivity aspirating smoke detector
Notes:
1)
For compliance with Clause 5.10 of EN54-20:2006, the detector shall be
supplied with power from a power supply complying with EN54-4.
2)
The approval of the detector is conditional upon the following requirements:
- Design, installation and commissioning are performed in accordance with the
system design manual and instructions.
3)
The device is approved for sensitivity Classes A, B and C for sensitivities up to
0.31%/m. The Class of any pipe/hole configuration and detector sensitivity must be
determined using PipeCAD.
High sensitivity aspirating smoke detector
Notes:
1)
For compliance with Clause 5.10 of EN54-20:2006, the detector shall be
supplied with power from a power supply complying with EN54-4.
2)
The approval of the detector is conditional upon the following requirements:
- Design, installation and commissioning are performed in accordance with the
system design manual and instructions.
3)
The device is approved for sensitivity Classes A, B and C for sensitivities up to
0.62%/m. The Class of any pipe/hole configuration and detector sensitivity must be
determined using PipeCAD.
High sensitivity aspirating smoke standard detector (Stratos HSSD 2 Stand Alone
Command Module Ancillary)
Notes:
1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied
with power from a power supply complying with EN 54-4.
2. The approval of the detector is conditional upon the following requirements:
 Design, installation and commissioning are performed in accordance with the
system design manual and instructions.
 The device is approved for sensitivity Classes A, B and C for sensitivities up
to 0.62%/m, 1.95%/m and 4.65%/m respectively.. The Class of any pipe/hole
configuration and detector sensitivity must be determined using PipeCAD.
High sensitivity aspirating command module smoke detector
Notes:
1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied
with power from a power supply complying with EN 54-4.
2. The approval of the detector is conditional upon the following requirements:
 Design, installation and commissioning are performed in accordance with the
system design manual and instructions.
 The device is approved for sensitivity Classes A, B and C for sensitivities up
to 0.62%/m, 1.95%/m and 4.65%/m respectively.. The Class of any pipe/hole
configuration and detector sensitivity must be determined using PipeCAD.
LPCB Ref.
No.
404c/01
404c/02
404c/03
404c/04
305
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
Stratos HSSD 2
High sensitivity aspirating minimum display version smoke detector (Stratos HSSD 2
Stand Alone Command Module Ancillary)
Notes:
1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied
with power from a power supply complying with EN 54-4.
2. The approval of the detector is conditional upon the following requirements:
 Design, installation and commissioning are performed in accordance with the
system design manual and instructions.
 The device is approved for sensitivity Classes A, B and C for sensitivities up
to 0.62%/m, 1.95%/m and 4.65%/m respectively.. The Class of any pipe/hole
configuration and detector sensitivity must be determined using PipeCAD.
High sensitivity aspirating standard smoke detector 1, 2, 3
Notes:
1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied
with power from a power supply complying with EN 54-4.
2. The approval of the detector is conditional upon the following requirements:
 Design, installation and commissioning are performed in accordance with the
system design manual and instructions.
 The device is approved for sensitivity Classes A, B and C for sensitivities up
to 0.80%/m, 1.66%/m and 7.54%/m respectively. The Class of any pipe/hole
configuration and detector sensitivity must be determined using PipeCAD.
Stratos Nano
LPCB Ref.
No.
404c/05
404c/06
Ancillaries:
Stratos HSSD 2 Stand Alone Command Module
Labor Strauss Sicherungsanlagenbau GmbH
Wiegelestrasse 36, A-1231 Vienna, Austria
Tel: +43 1 52114-44 • Fax: +43 1 52114-27
E-mail: [email protected] • Website: www.lst.at
Certificate No: 928e-(cl-11) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 928b-(cl-8) to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005
Smoke Detectors
Certificated Products
FI750/O
Analogue addressable photoelectric smoke detector with short-circuit isolator (F1750/B
base)
Notes:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
FC650/O
Conventional Photo Detector
(FC600/B, FC600/BR and FC600/BRD bases)
Bases
FC600/B
FC600/BR
FC600/BRD
F1750/B
LPCB Ref.
No.
928b/02
928e/02
Universal adaptor base
Universal adaptor base with resistor
Universal adaptor base with resistor and Schottky diode
Low profile adaptor base
Certificate No: 928a-(cl-8) to EN 54-5: 2000 + A1: 2002, EN 54-17: 2005
Point Heat Detector
Certificated Products
FI750/T
Base
FI750/B
306
Analogue addressable Class P heat detector with short-circuit isolator (F1750/B base)
Note:1. Meets the requirements of EN 54-5 for Class A1R, Class B and Class BS
LPCB Ref.
No.
928a/02
Low profile adaptor base
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 928d-(cl-11) to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
FC650/TDIFF/57
Conventional Class A1R Thermal Detector
(FC600/B, FC600/BR and FC600/BRD bases)
Conventional Class B Thermal Detector
(FC600/B, FC600/BR and FC600/BRD bases)
FC650/TMAX/78
Bases
FC600/B
FC600/BR
FC600/BRD
LPCB Ref.
No.
928d/02
928d/02
Universal adaptor base
Universal adaptor base with resistor
Universal adaptor base with resistor and Schottky diode
Certificate No: 928c-(cl-8) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005, CEA 4021: 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
FI750/OT
Base
FI750/B
Addressable multi-criteria detector with short-circuit isolator (F1750/B base)
Notes:
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following
settings:
Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
Multi Criteria Level 2 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 3 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
2.
Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
3.
Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
LPCB Ref.
No.
928c/02
Low profile adaptor base
Lichfield Fire & Safety Equipment Co. Ltd (LIFECO)
Unit 8, Calibre Industrial Park, Laches Close, Four Ashes, Wolverhampton WV10 7DZ, United Kingdom
Tel: +44 (0) 1902 798 706 • Fax: +44 (0) 1902 798 679
E-mail: [email protected] • Website: www.lifeco-uk.com
Certificate No: 506a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Photoelectric Smoke Detectors
Certificated Products
LF-PE-4100
LF-PE-4100 Conventional photoelectric smoke detector (AHMB-L base)
LPCB Ref.
No.
506a/01
Bases:
AHMB-L mounting base
Certificate No: 506c-(cl-1) to EN 54-5: 2000 + A1: 2002
20 Oct 2014
307
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Point Heat Detectors
Certificated Products
LFHD60
(2 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB031 base)
LPCB Ref.
No.
506c/01
Bases:
AHMB-031 mounting base
Mavili Elektronik Ticaret Ve Sanayi A.S.
Bostanci Dudullu Yolu, Kutup Sok, No. 29 Y Dudullu - Umraniye, Istanbul TR 34775, Turkey
Tel: +90 216 4664 505 • Fax: +90 216 4664 510
E-mail: [email protected] • Website: www.mavigard.com
Certificate No: 926a to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
MG-9100
LPCB Ref.
No.
926a/01
Intelligent analogue addressable system photoelectric smoke detector (MG-3510 base)
Bases:
MG-3510 standard mounting base
Certificate No: 926b to EN 54-5: 2000 + A1: 2002
Point Heat Detectors
Certificated Products
MG-9300
LPCB Ref.
No.
926b/01
Intelligent analogue addressable system class A1R rate of rise heat detector (MG-3510
base)
Bases:
MG-3510 standard mounting base
Certificate No: 926c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Multi-criteria Detectors
Certificated Products
MG-9400
Intelligent analogue addressable system class A1R multisensor detector (MG-3510 base)
LPCB Ref.
No.
926c/01
Bases:
MG-3510 standard mounting base
Morley-IAS Fire Systems By Honeywell
Honeywell Fire Systems, BSEL Tech Park, Floor 6,Sector 30A, Opposite Vshi Station, Vashi, New Mumbai,
India
Tel: +91 022 67122427 • Fax: +91 022 67122422
E-mail: [email protected] • Website: www.myhoneywell.com
Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003
Certificate No: 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003
308
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Multi-criteria Detectors
Certificated Products
MI-PTSE
MI-PTIR-S2-yy
MI-PTSE-S2-yy
MI-PTIR-S2I-yy
MI-PTSE-S2I-yy
Analogue optical/thermal smoke & heat detector (MI-B501 base)
Notes:
1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1 to 5
2) Meets the requirements of EN 54-5:2000 at Class A1R
Analogue addressable photo-thermal-IR multi-criteria detector (B501AP, B501,
B524IEFT-1, B524HTR and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria detector (B501AP, B501, B524IEFT-1,
B524HTR and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal-IR multi-criteria smoke detector with short circuit
isolator (B501AP, B524HTR and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria smoke detector with short circuit
isolator (B501AP, B524HTR and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
LPCB Ref.
No.
550b/03
550b/04
550b/05
550e/01
550e/02
Bases:
MI-B501 Standard analogue detector base
B501 standard analogue detector base
B501AP intelligent detector base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
Certificate No: 550c to EN 54-5: 2000 + A1: 2002
Certificate No: 550f to EN54-5: 2000 + A1: 2002 and EN 54-17: 2005
Point Heat Detectors
Certificated Products
MI-FHSE
MI-RHSE
MI-RHSE-S2-yy
MI-FHSE-S2-yy
MI-RHSE-S2I-yy
MI-FHSE-S2I-yy
20 Oct 2014
Analogue addressable Class A1S fixed temperature heat detector (MI-B501 base)
Analogue addressable Class A1R high temperature rate of rise heat detector (MI-B501
base)
Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1,
B524HTR and B524RTE bases)
Note:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Analogue addressable class A1S fixed temperature heat detector (B501AP, B501,
B524IEFT-1, B524HTR and B524RTE bases)
Note:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Analogue addressable class A1R rate of rise heat detector with short circuit isolator
(B501AP, B524HTR and B524RTE bases)
Note:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Analogue addressable class A1S fixed temperature heat detector with short circuit
isolator (B501AP, B524HTR and B524RTE bases)
Note:
LPCB Ref.
No.
550c/04
550c/05
550c/06
550c/07
550f/01
550f/02
309
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Bases:
MI-B501 Standard analogue detector base
B501 standard analogue detector base
B501AP intelligent detector base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 550d to EN54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Point Smoke Detectors
Certificated Products
MI-PSE
MI-PSE-S2-yy
MI-PSE-S2I-yy
LPCB Ref.
No.
550a/03
Analogue addressable optical smoke detector (MI-B501 base)
Note: Meets EN 54-7 with low, medium and high sensitivity settings
Analogue addressable optical smoke detector (B501AP, B501, B524IEFT-1, B524HTR
and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity
Analogue addressable optical smoke detector with short circuit isolator (B501AP,
B524HTR and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity
550a/04
550d/01
Bases:
MI-B501 standard analogue detector base
B501 standard analogue detector base
B501AP intelligent detector base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
Morley-IAS Fire Systems by Honeywell (Pittway Systems Technology Group (Europe)
Ltd)
Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom
Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888
E-mail: [email protected] • Website: www.morley-ias.co.uk
Certificate No: 199n to EN 54-5: 2000 + A1: 2002
Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005
Point Heat Detectors
Certificated Products
MI-FHSE-S2I
MI-HTSE-S2I
MI-RHSE-S2I
HRZ-1005T
HRZ-1004T
HRZ-1005
MI-RHSE-S2
310
Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator
(B501AP, B524HTR and B524RTE bases)
Analogue addressable class BS fixed temperature heat sensor with short circuit isolator
(B501AP, B524HTR and B524RTE bases)
Analogue addressable class A1R rate of rise heat sensor with short circuit isolator
(B501AP, B524HTR and B524RTE bases)
Class A2S conventional fixed temperature heat detector
(HRZ-1000BSD base)
Class BS conventional fixed temperature heat detector
(HRZ-1000BSD base)
Class A1R conventional rate of rise heat detector
(HRZ-1000BSD base)
Analogue addressable class A1R rate of rise heat sensor (B501AP, B501, B524IEFT-1,
B524HTR and B524RTE bases)
LPCB Ref.
No.
199ac/01
199ac/02
199ac/03
199n/10
199n/11
199n/12
199n/15
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
MI-HTSE-S2
MI-FHSE-S2
Analogue addressable class BS fixed temperature heat sensor (B501AP, B501,
B524IEFT-1, B524HTR and B524RTE bases)
Analogue addressable class A1S fixed temperature heat sensor (B501AP, B501,
B524IEFT-1, B524HTR and B524RTE bases)
LPCB Ref.
No.
199n/16
199n/17
Bases:
B501 standard analogue detector base
B501DG analogue deep base
B524IEFT analogue short circuit isolator base
B501AP intelligent sensor base
B524IEFT-1 short circuit isolator
B524HTR heater base
B524RTE latching relay base
HRZ-1000BSD standard base with Schottky diode
Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005
Multi-criteria Detectors
Certificated Products
MI-PTIR-S2I
MI-PTSE-S2I
HRZ-1002
MI-PTIR-S2
MI-PTSE-S2
Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit
isolator (B501AP, B524HTR and B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit
isolator (B501AP, B524HTR and B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Conventional photo thermal detector (HRZ-1000BSD base)
Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT1, B524HTR and B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1,
B524HTR and B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
LPCB Ref.
No.
199aa/01
199aa/02
199p/04
199p/06
199p/07
Bases:
B501 standard analogue detector base
B501AP intelligent detector base
B501DG analogue sensor deep base
B524IEFT analogue short circuit isolator base
B524IEFT-1 analogue sensor short circuit isolator base
B524HTR heater base
B524RTE latching relay base
HRZ-1000BSD standard base with Schottky diode
Certificate No: 199m to EN 54-7: 2000 + A1: 2002
Certificate No: 118h to EN 54-7: 2000
Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005
Point Smoke Detectors
Certificated Products
MI-LZR
MI-PSE-S2I
20 Oct 2014
Analogue addressable photoelectric laser smoke detector (B501, B501DG and B524IEFT
bases)
Meets the requirements of EN 54-7 at sensitivity settings of 7 to 9 inclusive.Analogue addressable optical smoke sensor with short circuit isolator (B501AP,
LPCB Ref.
No.
118h/01
199ab/01
311
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
HRZ-1003
MI-PSE-S2
LPCB Ref.
No.
B524HTR and B524RTE bases)
Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity
Conventional photoelectric detector (HRZ-1000BSD base)
Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR
and B524RTE bases)
Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity
199m/05
199m/10
Bases:
B501 analogue detector base
B501DG analogue deep base
B524IEFT analogue short circuit isolator base
B501AP intelligent sensor base
B524IEFT-1 short circuit isolator base
B524HTR heater base
B524RTE latching relay base
HRZ-1000BSD standard base with Schottky diode
Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005
Beam Detectors
Certificated Products
MI-LPB2-S2I
LPCB Ref.
No.
199w/01
Analogue optical beam detector with short circuit isolator feature
Note:
1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and
Acclimate levels 1 & 2
Ancillaries:
RTS151-KEY
6500 - LRK/BEAMLRK
6500 - MMK/BEAMMMK
6500 - SMK/BEAMSMK
Remote test Station
Long Range Kit
Multi-Mounting Kit
Surface Mounting Kit
Certificate No: 199ae to EN54-17: 2005 & EN54-20: 2006
Aspirating Smoke Detectors
Certificated Products
MI-FL2011EI
MI-FL2012EI
MI-FL2022EI
312
Analogue addressable single channel loop-based aspirating detector (B501AP base)
Notes:
1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by
a power supply complying with EN54-4.
2. The approval of the detector is conditional upon the following requirements: System
design, installation and commissioning shall be performed in accordance with the FAAST
Advanced set-up and control guide (I56-3888-000).
3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B
and C. The Class of any pipe/hole configuration and detector sensitivity must be
determined using PipeIQLT software (version 1.2.9).
Analogue addressable single channel loop-based aspirating detector, dual sensors
(B501AP base)
Notes:
1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be
supplied by a power supply complying with EN54-4.
2. The approval of the detector is conditional upon the following requirements:
System design, installation and commissioning shall be performed in accordance with
the FAAST Advanced set-up and control guide (I56-3888-000).
3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A,
B and C. The Class of any pipe/hole configuration and detector sensitivity must be
determined using PipeIQLT software 1.2.9).
Analogue addressable dual channel loop-based aspirating detector, dual sensors
(B501AP base)
Notes:
1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be
supplied by a power supply complying with EN54-4.
2. The approval of the detector is conditional upon the following requirements:
System design, installation and commissioning shall be performed in accordance with
the FAAST Advanced set-up and control guide (I56-3888-000).
LPCB Ref.
No.
199ae/01
199ae/02
199ae/03
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A,
B and C. The Class of any pipe/hole configuration and detector sensitivity must be
determined using PipeIQLT software 1.2.9).
Base:
B501AP
intelligent sensor base
Multron Systems Pte Ltd
217 Kallang Bahru, Multron Building, Singapore 339 347, Singapore
Tel: +65 6743 2555 / 6395 6868 • Fax: +65 6743 2777 / 6395 6869
E-mail: [email protected] • Website: www.multron.com
Certificate No: 548c-(cl-6) to EN 54-5: 2000 + A1: 2002
Certificate No: 1148a to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
DET-C632
DET-C103
DET-A103
Bases:
DZ-03
DB-6
Conventional rate of rise & fixed temperature heat detectorstandard base)
Note:
Meets the requirements of EN 54-5 at Class A2R
Conventional Class A1R heat detector (DZ-03 base)
Intelligent Class A1R heat detector
(DZ-03 base)
LPCB Ref.
No.
1148a/01
548c/01
548c/02
Standard detector base
Standard detector base
Certificate No: 548d-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 1148b to EN 54-7:2001 + A1: 2002 + A2: 2006
Photoelectric Smoke Detectors
Certificated Products
DET-C631
DET-C102
DET-A102
Bases:
DZ-03
DB-6
Conventional optical smoke detector
(DB-6 Standard base)
Note:
Meets the requirements of EN 54-7 in the normal sensitivity setting.
Conventional Photoelectric Smoke Detector
(DZ-03 base)
Intelligent Photoelectric Smoke Detector
(DZ-03 base)
LPCB Ref.
No.
1148b/01
548d/01
548d/02
Standard detector base
Standard detector base
Certificate No: 548k-(cl-6) to EN 54-12: 2002
Beam Detectors
Certificated Products
DET-105RB
20 Oct 2014
Intelligent Optical Beam Detector
Notes:
1: Meets the requirements of EN 54-12 at the following sensitivity settings:
Level 1 1.61 dBLevel 2 2.31dB
LPCB Ref.
No.
548k/01
313
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Nitin Ventures FZE
P.O. Box 262294, Jebel Ali Free Zone, Dubai, United Arab Emirates
Tel: +97 148865858/859 • Fax: +97 148865800
E-mail: [email protected] • Website: www.nitinfire.com
Certificate No: 010h-(cl-1) to EN 54-7: 2000 + A1: 2002, EN 54-5: 2000 + A1: 2002, CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
NV-I-MS
Analogue addressable multisensor detector (NV-IA-SB mounting base)
Notes:
1) Certificated at the following settings:
Mode 1 - High sensitivity smoke detector with standard heat enhancement
Mode 2 - Smoke detection only
Mode 3 - Medium sensitivity smoke detector with standard heat enhancement
Mode 4 - Low sensitivity smoke detector with high heat enhancement
Mode 5 - Class A1 heat detector
Also approved in conventional alarm modes 1, 2, 3, 4 and 5.
LPCB Ref.
No.
010h/01
Bases:
NV-IA-SB Mounting Base
Certificate No: 010p-(cl-1) to EN 54-5: 2000 + A1: 2002
Point Heat Detectors
Certificated Products
NV-I-H
NV-C-H-A1R
NV-C-H-CS
LPCB Ref.
No.
010p/03
Analogue addressable heat detector (NV-IA-SB mounting base)
Notes:
1) Meets the requirements of EN54: Part 5 Class A1R in mode 1 and in conventional mode
Class A2 in mode 2 and in conventional mode
Class A2S in mode 3 and in conventional mode
Class CR in mode 4 and in conventional mode
Class CS in mode 5 and in conventional mode.
Conventional class A1R heat detector - flashing LED (NV-C-SB mounting base)
Notes:
1) Meets the requirements of EN54: Part 5 - Class A1R
Series 65 Conventional Class CS heat detector Flashing LED (NV-C-SB mounting base)
Meets the requirements of EN54: Part 5 - Class CS
010p/05
010p/14
Bases:
NV-IA-SB mounting base
NV-C-SB mounting base
Certificate No: 010q-(cl-1) to EN 54-7: 2000 + A1: 2002
Point Smoke Detectors
Certificated Products
NV-I-I
NV-I-O
NV-C-I
NV-C-O
Analogue addressable ionisation smoke detector (NV-IA-SB mounting base)
Notes:
1) Meets the requirements of EN54-7: 2000 in modes 1,2,3,4 and 5 in conventional mode
Analogue addressable optical smoke detector (NV-IA-SB mounting base)
Notes:
1) Meets the requirements of EN54-7:2000 in modes 1,2,3 4 and 5 in conventional mode
Conventional ionisation smoke detector - flashing LED (NV-C-SB mounting base)
Conventional optical smoke detector- flashing LED (NV-C-SB mounting base)
LPCB Ref.
No.
010q/02
010q/03
010q/05
010q/11
Bases:
NV-IA-SB mounting base
NV-C-SB mounting base
314
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Nittan Europe Limited
Hipley Street, Old Woking, Surrey GU22 9LQ, United Kingdom
Tel: +44 (0)1483 769555/8 • Fax: +44 (0)1483 756686
E-mail: [email protected] • Website: www.nittan.co.uk
Certificate No: 041f to EN54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 842a-(cl-1) to EN-54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 755a-(cl-1) to EN54-7: 2000 + A1: 2002
Point Smoke Detectors
Certificated Products
EV-P
EVC-P
EVC-DP
EVC-P
ST-P-OM
ST-PY-AS
EV-P
Analogue addressable optical smoke detector (UB-4,UB-4-EV,UB-4-SD and STB-4SEEV bases)
Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only.
EVC-P Conventional optical smoke detector
(STB-4-SE-24VR, STB-4SE, UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases)
Conventional Dual Optical Smoke Detector
(STB-4, STB-4SD, STB-4SE, STB-4SE-24VR, UB-4 and UB-5 bases)
Conventional optical smoke detector
(STB-4-SE24VR, STB-4-SE ,STB-4 , UB-4 and UB-4SD bases)
Conventional optical smoke detector
(STB-4-SE24VR, STB-4-SE ,STB-4, UB-4 , UB-4R470 and UB-4SDR470 bases)
Analogue addressable photoelectric smoke detector (STB-4-SE ,STB-4 and UB-4 bases)
Analogue addressable photoelectric smoke detector
,STB-4-SE-EV and UB4-EV bases)
Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only.
LPCB Ref.
No.
041f/01
041f/03
755a/01
842a/01
842a/02
842a/03
842a/04
Bases
STB-4 Standard mounting base
STB-4SE-EV mounting base
STB-4SE Standard deep mounting base
STB-4SD Schottky diode mounting base
STB-4-SE-24VR Relay mounting base
UB-4 Universal mounting base 4 terminal
UB-5 Universal mounting base 5 terminal
UB-4-EV Universal base
UB-4SD Universal base with Shottky diode
Certificate No: 041h to EN 54-5: 2000 + A1: 2002
Point Heat Detectors
Certificated Products
EV-H-A1R
EV-H-CS
EVC-H-A2S
EVC-H-CS
Analogue addressable Class A1R heat detector
(UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases)
Analogue addressable Class CS heat detector
and STB-4SE-EV bases)
Conventional Class A2S heat detector
(UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases)
Conventional Class CS heat detector
and STB-4SE-EV bases)
LPCB Ref.
No.
041h/01
041h/02
041h/03
041h/04
Bases
UB-4 Universal base
UB-4-EV Universal base
UB-4SD Universal base with Shottky diode
STB-4SE-EV mounting base
Certificate No: 041g to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1:2002 + A2: 2006 and CEA4021: 1999
20 Oct 2014
315
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Multi-criteria Detectors
Certificated Products
EV-PH
LPCB Ref.
No.
041g/01
Analogue addressable optical smoke / class A1R heat detector
(UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases)
Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings.
Bases
UB-4 Universal base
UB-4-EV Universal base
UB-4SD Universal base with Shottky diode
STB-4SE-EV mounting base
Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd)
Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom
Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888
E-mail: [email protected] • Website: www.notifierfiresystems.co.uk
Certificate No: 199m to EN 54-7: 2000 + A1: 2002
Certificate No: 118h to EN 54-7: 2000 + A1: 2002
Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005
Point Smoke Detectors
Certificated Products
FSL-751E
NFXI-OPT
SD-851E
IDX-751 AE
NFX-OPT
LPCB Ref.
No.
118h/01
Analogue addressable photoelectric laser smoke detector
(B501, B501DG & B5241EFT bases)
Note: meets the requirements of EN 54:Part 7 at sensitivity settings of 7 to 9 inclusive.
Analogue addressable optical smoke sensor with short circuit isolator (B501AP,
B524HTR & B524RTE bases)
Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity
Conventional photoelectric smoke detector (B401 base)
Intrinsically safe analogue addressable photoelectric smoke detector (B501, B501AP
bases)
Note: Meets EN54-7: 2000 at High, Normal & Low sensitivity settings
Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR &
B524RTE bases)
Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity
199ab/01
199m/03
199m/07
199m/10
Bases:
B501 base
B401 base
B501DG deep base
B5241EFT short circuit isolator base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
B501AP Intelligent detector base
Certificate No: 199n to EN 54-5: 2000 + A1: 2002
Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005
Point Heat Detectors
Certificated Products
NFXI-TFIX58
NFXI-TFIX78
NFXI-TDIFF
FD-851RE
FD-851HTE
NFX-TDIFF
NFX-TFIX78
316
Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator
(B501AP, B524HTR & B524RTE bases)
Analogue addressable class BS fixed temperature heat sensor with short circuit isolator
(B501AP, B524HTR & B524RTE bases)
Analogue addressable class A1R rate of rise heat sensor with short circuit isolator
(B501AP, B524HTR & B524RTE bases)
Conventional Class A1R rate of rise heat detector (B401 base)
Conventional Class BS heat detector (B401 base)
Analogue addressable class A1R rate of rise heat sensor (B501AP, B501, B524IEFT-1,
B524HTR & B524RTE bases)
Analogue addressable class BS fixed temperature heat sensor (B501AP, B501,
LPCB Ref.
No.
199ac/01
199ac/02
199ac/03
199n/07
199n/08
199n/15
199n/16
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
NFX-TFIX58
LPCB Ref.
No.
B524IEFT-1, B524HTR & B524RTE bases)
Analogue addressable class A1S fixed temperature heat sensor (B501AP, B501,
B524IEFT-1, B524HTR & B524RTE bases)
199n/17
Bases:
B501 base
B401 base
B401R standard base with resistor
B401RSD standard base with resistor and schottky diode
B401SD standard base with schottky diode
B401DG deep base
B501AP intelligent sensor base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005
Multi-criteria Detectors
Certificated Products
NFXI-SMT3
NFXI-SMT2
SD-851TE
NFX-SMT3
NFX-SMT2
IRX-751CTEM
Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit
isolator (B501AP, B524HTR & B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit
isolator (B501AP, B524HTR & B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Conventional photoelectric/thermal detector (B401 base)
Note: Meets the requirements of EN54-7: 2000 at "High", 'Medium' and 'Low' sensitivity
settings
Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT1, B524HTR & B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1,
B524HTR & B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal
and IR sensors (B501, B501DG and B524IEFT-1 bases)
Note: Certified at the following settings: Normal Mode:
Alarm Levels 1 to 5 (Multi-criteria): EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021
Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R
Nuisance Environment Applications:
Application 0, Alarm Level 4
Application 1, Alarm Level 5
Application 2, Alarm Level 4 or 5
Application 3, Alarm Level 5
Application 4, Alarm Level 5
Application 5, Alarm Level 5
Application 6, Alarm Level 5
LPCB Ref.
No.
199aa/01
199aa/02
199p/03
199p/06
199p/07
199t/01
EN54-7, LPS1279 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
Bases:
B501 base
B401 base
B501DG deep base
20 Oct 2014
317
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
B524IEFT-1 analogue short circuit isolator base
B501AP intelligent sensor base
B524HTR heater base
B524RTE latching relay base
Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005
Beam Detectors
Certificated Products
NFXI-BEAM
NFXI-BEAM-T
Ancillaries:
RTS151-KEY
6500 - LRK/BEAMLRK
6500 - MMK/BEAMMMK
6500 - SMK/BEAMSMK
LPCB Ref.
No.
199w/01
Analogue optical beam detector with short circuit isolator feature.
Note:
1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and
Acclimate levels 1 & 2
Analogue optical beam detector with self test facility and short circuit isolator feature.
Note:
1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and
Acclimate levels 1 & 2
199w/02
Remote test Station
Long Range Kit
Multi-Mounting Kit
Surface Mounting Kit
Certificate No: 199af-(cl-1) to EN54-17: 2005 & EN54-20: 2006
Aspirating Smoke Detectors
Certificated Products
NFXI-ASD11
NFXI-ASD12
NFXI-ASD22
Base:
B501AP
318
Analogue addressable single channel loop-based aspirating detector
Notes:
1.
For compliance with Clause 5.10 of EN54-20: 2006, the detector must be
supplied by a power supply complying with EN54-4.
2.
The approval of the detector is conditional upon the following requirements:
System design, installation and commissioning shall be performed in accordance
with the FAAST Advanced set-up and control guide (I56-3888-000).
3.
The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A,
B and C. The Class of any pipe/hole configuration and detector sensitivity must
be determined using PipeIQLT software (version 1.2.9).
Analogue addressable single channel loop-based aspirating detector dual sensors
Notes:
1.
For compliance with Clause 5.10 of EN54-20: 2006, the detector must be
supplied by a power supply complying with EN54-4.
2.
The approval of the detector is conditional upon the following requirements:
System design, installation and commissioning shall be performed in accordance
with the FAAST Advanced set-up and control guide (I56-3888-000).
3.
The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A,
B and C. The Class of any pipe/hole configuration and detector sensitivity must
be determined using PipeIQLT software (version 1.2.9).
Analogue addressable dual channel loop-based aspirating detector dual sensors
Notes:
1.
For compliance with Clause 5.10 of EN54-20: 2006, the detector must be
supplied by a power supply complying with EN54-4.
2.
The approval of the detector is conditional upon the following requirements:
System design, installation and commissioning shall be performed in accordance
with the FAAST Advanced set-up and control guide (I56-3888-000).
3.
The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A,
B and C. The Class of any pipe/hole configuration and detector sensitivity must
be determined using PipeIQLT software (version 1.2.9).
LPCB Ref.
No.
199af/01
199af/02
199af/03
intelligent sensor base
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Notifier Fire Systems India
Honeywell Fire Systems, BSEL Tech Park, Floor 6, 603, Sector 30A, opposite Vashi Station, Vashi, New
Mumbia, India
Tel: +91 022 67122427 • Fax: +91 02267122422
E-mail: [email protected] • Website: www.myhoneywell.com
Certificate No: 550b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003
Certificate No: 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003
Multi-criteria Detectors
Certificated Products
SDX-751TEM
NFX-SMT2-yy
NFXI-SMT2-yy
Analogue optical/thermal smoke & heat detector (B501, B501DG and B5241EFT-1
bases)
Notes:
1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1 to 5
2) Meets the requirements of EN 54-5:2000 at Class A1R
Analogue addressable photo-thermal multi-criteria detector (B501AP, B501, B524IEFT-1,
B524HTR and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria smoke detector with short circuit
isolator (B501AP, B524HTR and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
LPCB Ref.
No.
550b/03
550b/05
550e/02
Bases:
B501 Standard base
B501DG Deep analogue detector base
B5242EFT-1 Short circuit islolator base
B501AP intelligent detector base
B524HTR heater base
B524RTE latching relay base
Certificate No: 550c to EN 54-5: 2000 + A1: 2002
Certificate No: 550f to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005
Point Heat Detectors
Certificated Products
FDX-551EM
FDX-551REM
NFX-TDIFF-yy
NFX-TFIX58-yy
NFXI-TDIFF-yy
NFXI-TFIX58-yy
20 Oct 2014
Analogue addressable Class A1S fixed temperature heat detector (B501,
B501DG and B5241EFT-1 bases)
Analogue addressable Class A1R high temperature rate of rise heat detector (B501,
B501DG and B5241EFT-1 bases)
Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1,
B524HTR and B524RTE bases)
Note:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Analogue addressable class A1S fixed temperature heat detector (B501AP, B501,
B524IEFT-1, B524HTR and B524RTE bases)
Note:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Analogue addressable class A1R rate of rise heat detector with short circuit isolator
(B501AP, B524HTR and B524RTE bases)
Note:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Analogue addressable class A1S fixed temperature heat detector with short circuit
LPCB Ref.
No.
550c/04
550c/05
550c/06
550c/07
550f/01
550f/02
319
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
isolator (B501AP, B524HTR and B524RTE bases)
Note:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Bases:
B501 Standard base
B501DG Deep analogue detector base
B542IEFT-1 Short circuit islolator base
B501AP intelligent detector base
B524HTR heater base
B524RTE latching relay base
Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 550d to EN54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Point Smoke Detectors
Certificated Products
SDX-751EM
NFX-OPT-yy
NFXI-OPT-yy
Analogue addressable optical smoke detector (B501, B501DG and B5241EFT-1 bases)
Notes:
1) Meets EN 54-7 with low, medium and high sensitivity settings
Analogue addressable optical smoke detector (B501AP, B501, B524IEFT-1, B524HTR
and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity
Analogue addressable optical smoke detector with short circuit isolator (B501AP,
B524HTR and B524RTE bases)
Notes:
1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity
LPCB Ref.
No.
550a/03
550a/04
550d/01
Bases:
B501 standard analogue detector base
B501DG deep analogue detector base
B5241EFT-1 analogue short circuit isolator base
B501AP intelligent detector base
B524HTR heater base
B524RTE latching relay base
Olympia Electronics S.A.
Kolindros Pierias, 60061, Greece
Tel: (+30) 2353051200 • Fax: (+30 )2353051486
E-mail: [email protected] • Website: www.olympia-electronics.gr
Certificate No: 1010b to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
BSR-6055/A
BS-655
Analogue addressable optical smoke detector (BSR-6055/A base)
Note:
1. Meets the requirements of EN 54-7: 2000 at sensitivity setting 0.120dB/m
Conventional optical smoke detector
(BS-655 base)
LPCB Ref.
No.
1010b/01
1010b/02
Bases
BS-655 Base
BSR-6055/A Base
320
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Orient Corporation Pte. Ltd.
Block 3018, Bedok North Street 5, #05-51, Eastlink Light Industrial Building 486132, Singapore
Tel: (+65) 6242 5489 • Fax: (+65) 6241 2291
E-mail: [email protected]
Certificate No: 506a-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
OCI 60041
Base
OCI 60041-MPB
(2 wire) Conventional photoelectric smoke detector (OCI 60041-MPB base)
LPCB Ref.
No.
506a/02
Mounting Base
Certificate No: 506b-(cl-3) to EN 54-7: 2000 + A1: 20002 + A2: 2006, EN 54-5: 2000 + A1: 2002 & CEA 4021: 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
OCI 60042
Base
OCI 60041-MPB
(2 Wire) Optical smoke and class A2 heat detector (OCI 60041-MPB base)
Note:1. Meets the requirements of EN54-5 for class A2
LPCB Ref.
No.
506b/01
Mounting Base
Certificate No: 506c-(cl-4) to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
OCI 60043
Base
OCI 60041-MPB
(2 Wire) Conventional Class A2 rate of rise and fixed temperature heat detector (OCI
60041-MPB base)
Note:1. Meets the requirements of EN54-5 for class A2
LPCB Ref.
No.
506c/01
Mounting base
Panasonic Corporation
1668, Fujikata, Tsu-shi, Mie-ken, Japan
Tel: +46 40 697 70 00 • Fax: +46 40 697 70 99
E-mail: [email protected] • Website: http://pesn.panasonic.se
Certificate No: 1012a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
Type 2840
Base:
Type 2843
Intrinsically safe analogue addressable photoelectric smoke detector
(Type 2843 base)
LPCB Ref.
No.
1012a/01
Intrinsically safe backbox
Certificate No: 1012b-(cl-1) to EN 54-5: 2000 + A1: 2002
20 Oct 2014
321
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Heat Detectors
Certificated Products
Type 2841
Base:
Type 2843
Intrinsically safe analogue addressable class P heat detector
(Type 2843 base)
Note:
Meets EN54 Part 5 for classes A1, A2S & BS
LPCB Ref.
No.
1012b/01
Intrinsically safe backbox
Pelco Finland Oy
Sokerilinnantie 11C, 02600, Espoo, Finland
Tel: +358 10 446 511 • Fax: +358 10 446 5103
E-mail: [email protected] • Website: www.pelco.com/nordic
Certificate No: 199u to EN 54-12: 2002
Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005
Beam Detectors
Certificated Products
EB-6500R
EB-6500RS
EB-6500A
EB-6500SA
Ancillaries:
RTS151-KEY
6500 - LRK/BEAMLRK
6500 - MMK/BEAMMMK
6500 - SMK/BEAMSMK
Conventional optical beam detector
Note:
1. Meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate
levels 1 & 2
Conventional optical beam detector with self test facility
Note:
1. Meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate
levels 1 & 2
Analogue optical beam detector with short circuit isolator feature
Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and
Acclimate levels 1 & 2
Analogue optical beam detector with self test facility and short circuit isolator feature
Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and
Acclimate levels 1 & 2
LPCB Ref.
No.
199u/01
199u/02
199w/01
199w/02
Remote test Station
Long Range Kit
Multi-Mounting Kit
Surface Mounting Kit
Certificate No: 199m to EN 54-7: 2000 + A1: 2002
Smoke Detectors
Certificated Products
ED2351E
Conventional photoelectric detector
(B401, B401DG, B401R, B401SD and B401RSD bases)
Note:
1. Meets EN 54-7: 2000 with Low, Medium and High sensitivites
LPCB Ref.
No.
199m/03
Bases:
B401 standard base
B401DG deep base
B401R standard base with 470 ohm resistor
B401SD standard base with schottky diode
B401RSD standard base with 470 ohm resistor and schottky diode
B501 Analogue sensor base
B501DG Analogue sensor deep base
B524IEFT Analogue sensor isolator base
B524HTR Heater base
B524RTE Latching relay base
322
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 199n to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
ED5351E
ED4351E
ED5351TE
Class A1R conventional rate of rise heat detector
(B401, B401DG, B401R and B401RSD bases)
Class BS conventional heat detector
(B401, B401DG, B401R, B401SD and B401RSD bases)
Class A2S conventional fixed temperature heat detector
(B401, B401R, B401RSD, B401SD and B401DG bases)
LPCB Ref.
No.
199n/07
199n/08
199n/14
Bases:
B401 standard base
B401DG deep base
B401R standard base with 470 ohm resistor
B401SD standard base with schottky diode
B401RSD standard base with 470 ohm resistor and schottky diode
B501 analogue sensor base
B501AP intelligent detector base
B501DG analogue sensor deep base
B524IEFT analogue sensor isolator base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
Certificate No: 199p to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
Certificate No: 010aq-(cl-2) to LPS 1274: 2005 EN 54-5: 2000 + A1: 2002 LPS 1265: 2004
Multi Criteria Detectors
Certificated Products
EDI-55
Analogue addressable CO/heat multisensor detector
(EBI-10 base)
Notes:
1.
Approved with the following mode configurations:Mode 1
30 ppm with high thermal enhancement (most sensitive)
Mode 2
33 ppm with CO only
Mode 3
40 ppm with low thermal enhancement (nominal sensitivity)
Mode 4
45 ppm with high thermal enhancement (least sensitive)
Mode 5
heat onlyA1R
2.
Mode 1 , 3, and 4 are approved to LPS1274:2005 and EN 54-5:2000 + A1:
2002
3.
Mode 2 is approved to LPS 1265:2004
4.
Mode 5 is approved to EN 54-5:2000 + A1:2002
LPCB Ref.
No.
010aq/01
Conditions of approval include;
ED2351TEM
ESMI2251CTLE
The EDI-55 should only be installed in accordance with the manufacturers
recommendations.
The EDI-55 should not be set only as a carbon monoxide fire detector where there is a
specific risk of rapid burning/flaming fires.
Refer to technical publication D01692 for limitations on the use of carbon monoxide fire
detection.
Conventional optical/thermal smoke & heat detector
(B401, B401DG, B401R, B401SD and B401RSD bases)
Note:
1. Meets the requirements of EN 54-5: 2000 at class A1R and EN 54-7: 2000 at High,
Medium and Low.
Analogue addressable multi-criteria fire detector and incorporating CO, photoelectric,
thermal and IR sensors (B501, B501AP, B501DG and B524IEFT-1 bases)
Note: Certified at the following settings: Normal Mode:
Alarm Levels 1 to 5 (Multi-criteria) EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021
Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R
199p/03
199t/01
Nuisance Environment Applications:
20 Oct 2014
323
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
Application 0,
Application 1,
Application 2,
Application 3,
Application 4,
Application 5,
Application 6,
Alarm Level 4
Alarm Level 5
Alarm Level 4 or 5
Alarm Level 5
Alarm Level 5
Alarm Level 5
Alarm Level 5
EN54-7, LPS1279 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
Bases:
B401 standard base
B401DG deep base
B401R standard base with 470 ohm resistor
B401SD standard base with schottky diode
B401RSD standard base with 470 ohm resistor and schottky diode
B501 standard analogue detector base
B501AP intelligent detector base
B501DG Deep detector base
B524IEFT Short circuit isolator base
B524HTR Heater base
B524RTE Latching relay base
EBI-10 Standard Intelligent Mounting Base
Philton Fire & Security Limited
61 Lower Road, Harrow, Middlesex HA2 0DE, United Kingdom
Tel: +44(0) 20-8864-7534 • Fax: +44(0) 20 8864 8631
E-mail: [email protected] • Website: www.philton.com
Certificate No: 404c to EN54-20:2006
Aspirating Smoke Detecors
Certificated Products
Guardian LaserSTAMP
high sensitivity aspirating
smoke detector
Notes:
1.
2.
3.
LPCB Ref.
No.
404c/01
For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be
supplied with power from a power supply complying with EN 54-4.
The approval of the detector is conditional upon the following requirements:
- Design, installation and commissioning are performed in accordance
with the system design manual and instructions.
The device is approved for sensitivity Classes A, B and C for sensitivities up to
0.31%/m. The Class of any pipe/hole configuration and detector sensitivity
must be determined using PipeCAD.
Pittway Tecnologica Srl.
Via Caboto 19/3, 34147 Trieste, Italy
Tel: +39 040 94 90111 • Fax: +39 040 38 2137
E-mail: [email protected] • Website: www.systemsensoreurope.com
European Sales:
System Sensor Europe, Life Safety Distribution AG, Wilstrasse 11 (Building U31), CH-8610 Uster, Switzerland
Tel: +41 44 943 4424 • Fax: +41 44 943 4399
E-mail: [email protected] • Website: www.systemsensoreurope.com
Certificate No: 199m to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005
324
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Point Smoke Detectors
Certificated Products
22051EI
ECO1003
2351E
Vision 2020P
22051EISE
22051E
Analogue addressable optical smoke sensor with short circuit isolator (B501AP,
B524HTR and B524RTE bases)
Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity
Conventional photoelectric smoke detector (ECO1000DB, ECO1000DBR and
ECO1000DBRSD)
Conventional photoelectric smoke detector (B401, B40DG, B401R, B401SD and
B401RSD bases)
Note: Meets the requirements of EN54-7:2000 at low, medium and high sensitivity
settings
Conventional photoelectric detector (2020B, 2020DB, 2020BSD, 2020DBSD bases)
Intrinsically safe analogue addressable photoelectric smoke detector (B501, B501AP,
B524HTR and B524RTE bases)
Note: Meets EN54-7: 2000 at High, Normal & Low sensitivity settings
Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR &
B524RTE bases)
Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity
LPCB Ref.
No.
199ab/01
199m/01
199m/03
199m/05
199m/07
199m/10
Bases:
2020B standard base
2020DB deep base
2020BSD standard base with schottky diode
2020DBSD deep base with schottky diode
B401 standard base
B401DG deep base
B401R standard base with 470 ohm resistor
B401SD standard base with schottky diode
B401RSD standard base with 470 ohm resistor and schottky diode
B501 standard analogue detector base
B501AP intelligent detector base
B501DG analogue sensor deep base
B524IEFT analogue sensor isolator base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
ECO1000B standard base.
ECO1000BSD standard base with schottky diode.
ECO1000BR standard base, 470 ohm resistor.
ECO1000BRSD standard base, 470 ohm resistor and schottky diode.
ECO1000BR680 standard base, 680 ohm resistor.
ECO1000BR680SD standard base, 680 ohm resistor and schottky diode.
ECO1000BR1000 standard base, 1000 ohm resistor.
ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode.
ECO1000DB deep base
ECO1000DBR deep base with 470 ohm resistor
ECO1000DBRSD deep base with 470 ohm resistor and schottky diode
ECO2000B mounting base.
Certificate No: 199n to EN 54-5: 2000 + A1: 2002
Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005
Point Heat Detectors
Certificated Products
52051EI
52051HTEI
52051REI
ECO1005
ECO1005T
5351E
4351E
20 Oct 2014
Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator
(B501AP, B524HTR and B524RTE bases)
Analogue addressable class BS fixed temperature heat sensor with short circuit isolator
(B501AP, B524HTR and B524RTE bases)
Analogue addressable class A1R rate of rise heat sensor with short circuit isolator
(B501AP, B524HTR and B524RTE bases)
Class A1R conventional thermal detector (ECO1000B, ECO1000BSD, ECO1000BR,
ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000,
ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases)
Class A2S conventional fixed temperature heat detector (ECO1000B, ECO1000BSD,
ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD,
ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and
ECO1000DBRSD bases)
Class A1R conventional rate of rise heat detector (B401, B401DG, B401R, B401SD, &
B401RSD bases)
Class BS conventional heat detector (B401, B401
LPCB Ref.
No.
199ac/01
199ac/02
199ac/03
199n/01
199n/06
199n/07
199n/08
325
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
ECO1004T
Vision 2020F
Vision 2020HF
Vision 2020R
5451EIS
5351TE
52051RE
52051HTE
52051E
LPCB Ref.
No.
DG, B401R, B401SD, & B401RSD bases)
Class BS conventional high temperature heat detector (ECO1000DB, ECO1000DBR,
ECO1000DBRSD, ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD,
ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases)
Class A2S conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD,
2020DBSD bases)
Class BS conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD,
2020DBSD bases)
Class A1R conventional rate of rise heat detector (2020B, 2020DB, 2020BSD,
2020DBSD bases)
Intrinsically safe conventional A1R heat detector (B401 base)
Conventional class A2S fixed temperature heat detector
(B401, B401R, B401RSD, B401SD, B401DG bases)
Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1,
B524HTR and B524RTE bases)
Analogue addressable class BS fixed temperature heat detector (B501AP, B501,
B524IEFT-1, B524HTR and B524RTE bases)
Analogue addressable class A1S fixed temperature heat detector (B501AP, B501,
B524IEFT-1, B524HTR and B524RTE bases)
199n/09
199n/10
199n/11
199n/12
199n/13
199n/14
199n/15
199n/16
199n/17
Bases:
2020B standard base
2020DB deep base
2020BSD standard base with schottky diode
2020DBSD deep base with schottky diode
B401 standard base
B401DG deep base
B401R standard base with 470 ohm resistor
B401SD standard base with schottky diode
B401RSD standard base with 470 ohm resistor and schottky diode
B401R1000 standard base with 1000 ohm resistor
B401DGR deep base with 470 ohm resistor
B401DGR1000 deep base with 1000 ohm resistor
B401DGSD deep base with schottky diode
B501 standard analogue detector base
B501AP intelligent detector base
B501DG analogue sensor deep base
B524IEFT analogue sensor isolator base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
ECO1000B standard base.
ECO1000BSD standard base with schottky diode.
ECO1000BR standard base, 470 ohm resistor.
ECO1000BRSD standard base, 470 ohm resistor and schottky diode.
ECO1000BR680 standard base, 680 ohm resistor.
ECO1000BR680SD standard base, 680 ohm resistor and schottky diode.
ECO1000BR1000 standard base, 1000 ohm resistor.
ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode.
ECO2000B mounting base.
ECO1000DB deep base.
ECO1000DBR deep base with 470 ohm resistor
ECO1000DBRSD deep base with 470 ohm resistor and schottky diode.
Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003
Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A1: 2006 & CEA 4021: 2003
Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005
Multi-criteria Detectors
Certificated Products
22051TLEI
22051TEI
326
Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit
isolator (B501AP, B524HTR & B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria smoke sensor
with short circuit isolator (B501AP, B524HTR & B524RTE bases)
Note: Certified at the following settings: -
LPCB Ref.
No.
199aa/01
199aa/02
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
ECO1002
2351TEM
Vision 2020PT
22051TLE
22051TE
2251CTLE-xx-yy
LPCB Ref.
No.
Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Conventional photo-thermal detector (ECO1000B, ECO1000BSD, ECO1000BR,
ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000,
ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases)
Note :Meets the requirements of EN54:5-2000 at class A1R and EN54:7:2000 at pre-set
sensitivity
Conventional optical/thermal detector (B401, B401DG, B401R, B401SD, & B401RSD
bases)
Note: Meets the requirements of EN54-5:2000 at class A1R and EN54-7:2000 at 'High'
'Medium' and 'Low' sensitivity settings.
Conventional photo thermal detector (2020B, 2020DB, 2020BSD and 2020DBSD bases)
Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT1, B524HTR and B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria sensor
(B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)
Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal
and IR sensors (B501, B501AP, B501DG, B524IEFT-1, B524HTR and B524RTE bases)
Notes:
1.) xx = (Range 0-99) ~ indicates the communication software protocol
2.) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
3.) Certified at the following settings: Normal Mode:
Alarm Levels 1 to 5 (Multi-criteria) EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021
Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R
Nuisance Environment Applications:
Application 0, Alarm Level 4
Application 1, Alarm Level 5
Application 2, Alarm Level 4 or 5
Application 3, Alarm Level 5
Application 4, Alarm Level 5
Application 5, Alarm Level 5
Application 6, Alarm Level 5
Application 7, Alarm Level 5
199p/01
199p/03
199p/04
199p/06
199p/07
199t/01
EN54-7, LPS1279 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-7 & CEA 4021
EN54-5 Class A1R, EN54-7 & CEA 4021
EN54-5 Class A1R, LPS1279 and CEA 4021
Bases:
2020B standard base
2020DB deep base
2020BSD standard base with schottky diode
2020DBSD deep base with schottky diode
B401 standard base
B401DG deep base
B401R standard base with 470 ohm resistor
B401SD standard base with schottky diode
B401RSD standard base with 470 ohm resistor and schottky diode
B401R1000 standard base with 1000 ohm resistor
B401DGR deep base with 470 ohm resistor
B401DGR1000 deep base with 1000 ohm resistor
B401DGSD deep base with schottky diode
B501 standard analogue detector base
B501AP intelligent detector base
B501DG analogue sensor deep base
B524IEFT analogue sensor isolator base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
ECO1000B standard base
ECO1000BSD standard base with schottky diode
ECO1000BR standard base, 470 ohm resistor
ECO1000BRSD standard base, 470 ohm resistor and schottky diode
ECO1000BR680 standard base, 680 ohm resistor
ECO1000BR680SD standard base, 680 ohm resistor and schottky diode
20 Oct 2014
327
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
ECO1000BR1000 standard base, 1000 ohm resistor
ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode
ECO1000DB deep base
ECO1000DBR deep base with 470 ohm resistor
ECO1000DBRSD deep base with 470 ohm resistor and schottky diode
ECO2000B mounting base
Certificate No: 199u to EN 54-12: 2002
Certificate No: 199w to EN 54-12: 2002 & EN 54-17: 2005
Beam Detectors
Certificated Products
6500R
6500RS
6500-yy
6500S-yy
LPCB Ref.
No.
199u/01
Conventional optical beam detector
Note: meets the requirements of EN 54-12: 2002
at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2
Conventional optical beam detector with self test facility
Note: meets the requirements of EN 54-12: 2002
at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2
Analogue optical beam detector with short circuit isolator feature
Note:
1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1,2,3,4 and
Acclimate levels 1 & 2
2. yy = (Range 00-99) and indicates the software protocol
Analogue optical beam detector with self test facility and short circuit isolator feature
Note:
1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1,2,3,4 and
Acclimate levels 1 & 2
2. yy = (Range 00-99) and indicates the software protocol
Ancillaries:
RTS151-KEY
6500 - LRK/BEAMLRK
6500 - MMK/BEAMMMK
6500 - SMK/BEAMSMK
199u/02
199w/01
199w/02
Remote test Station
Long Range Kit
Multi-Mounting Kit
Surface Mounting Kit
Certificate No: 199ad to EN54-20: 2006
Certificate No: 199ae to EN54-17: 2005 and EN54-20: 2006
Aspirating Smoke Detectors
Certificated Products
FL0111E
FL0112E
FL0122E
328
Analogue addressable stand alone single channel aspirating detector
Notes:
1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by
a power supply complying with EN54-4.
2. The approval of the detector is conditional upon the following requirements: System
design, installation and commissioning shall be performed in accordance with the FAAST
Advanced set-up and control guide (I56-3888-000).
3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B
and C. The Class of any pipe/hole configuration and detector sensitivity must be
determined using PipeIQLT software (version 1.2.9).
Analogue addressable stand alone single channel aspirating detector dual sensors
Notes:
1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by
a power supply complying with EN54-4.
2. The approval of the detector is conditional upon the following requirements: System
design, installation and commissioning shall be performed in accordance with the FAAST
Advanced set-up and control guide (I56-3888-000).
3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B
and C. The Class of any pipe/hole configuration and detector sensitivity must be
determined using PipeIQLT software (version 1.2.9).
Analogue addressable stand alone dual channel aspirating detector dual sensors
Notes:
1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by
a power supply complying with EN54-4.
2. The approval of the detector is conditional upon the following requirements: System
design, installation and commissioning shall be performed in accordance with the FAAST
Advanced set-up and control guide (I56-3888-000).
LPCB Ref.
No.
199ad/01
199ad/02
199ad/03
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
FL2011EI
FL2012EI
FL2022EI
Base:
B501AP
LPCB Ref.
No.
3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B
and C. The Class of any pipe/hole configuration and detector sensitivity must be
determined using PipeIQLT software (version 1.2.9).
Analogue addressable single channel loop-based aspirating detector (B501AP base)
Notes:
1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by
a power supply complying with EN54-4.
2. The approval of the detector is conditional upon the following requirements: System
design, installation and commissioning shall be performed in accordance with the FAAST
Advanced set-up and control guide (I56-3888-000).
3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B
and C. The Class of any pipe/hole configuration and detector sensitivity must be
determined using PipeIQLT software (version 1.2.9).
Analogue addressable single channel loop-based aspirating detector dual sensors
(B501AP base)
Notes:
1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by
a power supply complying with EN54-4.
2. The approval of the detector is conditional upon the following requirements: System
design, installation and commissioning shall be performed in accordance with the FAAST
Advanced set-up and control guide (I56-3888-000).
3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B
and C. The Class of any pipe/hole configuration and detector sensitivity must be
determined using PipeIQLT software (version 1.2.9).
Analogue addressable dual channel loop-based aspirating detector dual sensors
(B501AP base)
Notes:
1. For compliance with Clause 5.10 of EN54-20: 2006, the detector must be supplied by
a power supply complying with EN54-4.
2. The approval of the detector is conditional upon the following requirements: System
design, installation and commissioning shall be performed in accordance with the FAAST
Advanced set-up and control guide (I56-3888-000).
3. The device is only approved at sensitivity Level 1 (0.07%/m) meeting Classes A, B
and C. The Class of any pipe/hole configuration and detector sensitivity must be
determined using PipeIQLT software (version 1.2.9).
199ae/01
199ae/02
199ae/03
intelligent sensor base
Plana Fabrega
C/Caracas, 08030, Barcelona, Spain
Tel: 0034 93 243 1111 • Fax: 0034 93 243 0350
E-mail: [email protected]; [email protected]
Certificate No: 199m to EN 54-7: 2000 + A1: 2002
Smoke Detectors
Certificated Products
OPT1
Conventional photoelectric smoke detector
(ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680,
ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB,
ECO1000DBR, ECO1000DBRSD bases)
LPCB Ref.
No.
199m/01
Bases:
ECO1000B standard base
ECO1000BSD standard base with schottky diode
ECO1000BR standard base, 470 ohm resistor
ECO1000BRSD standard base, 470 ohm resistor and schottky diode
ECO1000BR680 standard base, 680 ohm resistor
ECO1000BR680SD standard base, 680 ohm resistor and schottky diode
ECO1000BR1000 standard base, 1000 ohm resistor
ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode
ECO1000DB deep base
ECO1000DBR deep base with 470 ohm resistor
ECO1000DBRSD deep base with 470 ohm resistor and schottky diode
20 Oct 2014
329
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 199n to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
TEVOL
Conventional photoelectric smoke detector
(ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680,
ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB,
ECO1000DBR, ECO1000DBRSD bases)
LPCB Ref.
No.
199n/01
Bases:
ECO1000B standard base
ECO1000BSD standard base with schottky diode
ECO1000BR standard base, 470 ohm resistor
ECO1000BRSD standard base, 470 ohm resistor and schottky diode
ECO1000BR680 standard base, 680 ohm resistor
ECO1000BR680SD standard base, 680 ohm resistor and schottky diode
ECO1000BR1000 standard base, 1000 ohm resistor
ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode
ECO1000DB deep base
ECO1000DBR deep base with 470 ohm resistor
ECO1000DBRSD deep base with 470 ohm resistor and schottky diode
Protec Fire Detection plc
Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom
Tel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273
E-mail: [email protected] • Website: www.protec.co.uk
Certificate No: 201f to EN 54-7: 2000
Certificate No: 201p to EN 54-7: 2000
Certificate No: 201ab to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Certificate No: 201v to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
6000PLUS/OP/S
6000PLUS/OP/SX
6000/OP
6000PLUS/OP
3000PLUS/OP
Analogue addressable smoke detector with indoor sounder and short circuit isolator
(6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting
2) Meets the requirements of EN 54-3: 2001 with the following tones:
i)
Continuous, 990Hz
ii) Warble, 990Hz for 250ms and 730Hz for 250ms
Analogue addressable smoke detector with indoor sounder and short circuit isolator
(export) (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting
2) Meets the requirements of EN 54-3: 2001 with the following tones:
i)
Continuous, 990Hz
ii) Warble, 990Hz for 250ms and 730Hz for 250ms
iii) Dutch Whoop, 500-1500Hz over 3s
MK II Analogue addressable optical smoke detector (6000/BASE and 6000/DIB bases)
Note: Meets requirements of EN 54-7: 2000 at the following mode settings:
i. Normal sensitivity mode
Analogue addressable smoke detector
(6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes: Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting
Conventional Optical Scatter Smoke Detector (3000PLUS/BASE & 3000PLUS/FFBASE
Bases)
Note:
1. Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting
LPCB Ref.
No.
201ab/01
201ab/02
201p/01
201v/01
201v/02
Bases:
6000/BASE Standard low profile base
6000/DIB Isolator base
330
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
3000/BASE Standard Base
6000PLUS/BASE, Standard mounting base
6000PLUS/FFBASE, Recessed mounting base
N28-075-01, Plug and Play Fast Fix base
N28-075-02, Plug and Play Surface base
3000PLUS/BASE Standard Mounting Base
3000PLUS/FFBASE Fast Fix Mounting Base
Certificate No: 201g to EN 54-5: 2000 + A1: 2002
Certificate No: 201r to EN 54-5: 2000
Certificate No: 201w to EN 54-5: 2000 + A1: 2002
Certificate No: 201aa to EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Point Heat Detectors
Certificated Products
6000PLUS/HT/S
6000PLUS/HT/SL
6000PLUS/HT/TSL
6000/TEMP
6000PLUS/HT
3000PLUS/TEMP56
3000PLUS/TEMP64
Analogue addressable heat detector with indoor sounder and short circuit isolator
(6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2
2) Meets the requirements of EN 54-3: 2001 with the following tones:
i)
Continuous, 990Hz
ii) Warble, 990Hz for 250ms and 730Hz for 250ms
Analogue addressable heat detector with indoor sounder, short circuit isolator and
beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2
2) Meets the requirements of EN 54-3: 2001 with the following tones:
i)
Continuous, 990Hz
ii) Warble, 990Hz for 250ms and 730Hz for 250ms
3) The beacon functionality is not included within the scope of this approval
Analogue addressable heat detector with talking indoor sounder, short circuit isolator and
beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2
2) Meets the requirements of EN 54-3: 2001 with the following tones:
i) Continuous 990Hz
ii) Warble, 990Hz for 250ms and 730Hz for 250ms
iii) Bell, 800Hz
iv) Voice message, F_EVAC2: Female voice “evacuation message” V2,
“Attention, attention. This is an emergency. Please leave the building by the nearest
available exit”.
3) The beacon functionality is not included within the scope of this approval
Analogue addressable heat detector (6000/BASE & 6000/DIB bases)
Note: Meets requirements of EN 54-5: 2000 at Class A1 (High sensitivity) and A2
(Normal sensitivity).
Analogue addressable heat detector (6000PLUS/BASE, 6000PLUS/FFBASE, N28-07501 and N28-075-02 bases)
Note: Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2
Conventional Class A1 Heat Detector (3000PLUS/BASE, 3000PLUS/FFBASE)
Notes:
1. Meets the requirements of EN 54-5: 2000 at Class A1
Conventional Class A2 Heat Detector (3000PLUS/BASE, 3000PLUS/FFBASE)
Notes:
1. Meets the requirements of EN 54-5: 2000 at Class A2
LPCB Ref.
No.
201aa/01
201aa/02
201aa/03
201r/01
201w/01
201w/02
201w/03
Bases:
3000/BASE standard base
6000/BASE standard low profile base
6000/DIB isolator base
6000PLUS/BASE, standard mounting base
6000PLUS/FFBASE, recessed mounting base
N28-075-01, Plug and Play Fast Fix base
N28-075-02, Plug and Play Surface base
20 Oct 2014
331
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 201j to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003
Certificate No: 201q to EN 54-5: 2000, EN 54-7: 2000 and CEA 4021
Certificate No: 201s to EN 54-5: 2000, EN 54-7: 2000 and CEA 4021
Certificate No: 201u to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003
Certificate No: 201x to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003, EN 54-3: 2001 + A1: 2002
+ A2: 2006 and EN 54-17: 2005
Certificate No: 201y to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005, CEA4021: 2003
Certificate No: 201z to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003, EN 54-3: 2001 + A1: 2002
+ A2: 2006 and EN 54-17: 2005
Certificate No: 201ac to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005, CEA4021: 2003
Multi-criteria Detectors
Certificated Products
6000PLUS/OPHT/I
6000/OPHT Mk II
6000/OPHTCO
6000PLUS/OPHT
6000PLUS/OPHT/S
6000PLUS/OPHT/SX
6000PLUS/OPHT/SL
6000PLUS/OPHT/TS
332
Analogue addressable multisensor detector with short circuit isolator (6000PLUS/BASE,
6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
Analogue addressable optical smoke and Class A2 heat multisensor detector
(6000/BASE & 6000/DIB bases).
Note:
1)
Meets requirements of EN 54-7: 2000 and CEA 4021 at the following mode
settings only:
i)
Normal sensitivity mode
ii)
Low sensitivity mode
Analogue addressable optical smoke, CO and Class A2 heat multisensor detector
(6000/BASE & 6000/DIB bases)
Notes:
1)
Meets requirements of EN 54-7: 2000 and CEA 4021 at the following mode
settings only:
i)
Normal sensitivity mode
II)
Low sensitivity mode
2)
The CO element is not LPCB approved
Analogue addressable multisensor detector (6000PLUS/BASE, 6000PLUS/FFBASE,
N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
Analogue addressable multisensor detector with indoor sounder and short circuit isolator
(6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
3) Meets the requirements of EN 54-3: 2001 with the following tones:
i)
Continuous, 990Hz
ii)
Warble, 990Hz for 250ms and 730Hz for 250ms
Analogue addressable multisensor detector with indoor sounder and short circuit isolator
(export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
3) Meets the requirements of EN 54-3: 2001 with the following tones:
i) Continuous, 990Hz
ii) Warble, 990Hz for 250ms and 730Hz for 250ms
iii) Dutch Whoop, 500-1500Hz over 3s
Analogue addressable multisensor detector with indoor sounder, short circuit isolator and
beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
3) Meets the requirements of EN 54-3: 2001 with the following tones:
i) Continuous 990Hz
ii) Warble, 990Hz for 250ms and 730Hz for 250ms
4) The beacon functionality is not included within the scope of this approval
Analogue addressable multisensor detector with talking indoor sounder and short circuit
isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
3) Meets the requirements of EN 54-3: 2001 with the following tones:
i) Continuous, 990Hz
LPCB Ref.
No.
201ac/01
201q/01
201s/01
201u/01
201x/01
201x/02
201x/03
201x/04
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
6000PLUS/OPHT/TSX
6000PLUS/OPHT/TSL
6000PLUS/OPHTCO
6000PLUS/OPHTCO/S
6000PLUS/OPHTCO/SX
6000PLUS/OPHTCO/SL
6000PLUS/OPHTCO/TSL
20 Oct 2014
LPCB Ref.
No.
ii) Warble, 990Hz for 250ms and 730Hz for 250ms
iii) Bell, 800Hz
iv) Voice Message, F_EVAC2: Female voice evacuation message V2,
Attention, attention. This is an emergency. Please leave the building by the nearest
available exit.
Analogue addressable multisensor detector with talking indoor sounder and short circuit
isolator (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02
bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
3) Meets the requirements of EN 54-3: 2001 with the following tones:
i) Continuous, 990Hz
ii) Warble, 990Hz for 250ms and 730Hz for 250ms
iii) Dutch Whoop, 500-1500Hz over 3s
iv) Bell, 800Hz
Analogue addressable multisensor detector with talking indoor sounder, short circuit
isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-07502 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
3) Meets the requirements of EN 54-3: 2001 with the following tones:
i) Continuous, 990Hz
ii) Warble, 990Hz for 250ms and 730Hz for 250ms
iii) Bell, 800Hz
iv) Voice message, F_EVAC2: Female voice evacuation message V2,
Attention, attention. This is an emergency. Please leave the building by the nearest
available exit.
4) The beacon functionality is not included within the scope of this approval
Analogue addressable multisensor and CO detector with short circuit isolator
(6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
3) The CO functionality is not included within the scope of this approval
Analogue addressable multisensor and CO detector with indoor sounder and short circuit
isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
3) Meets the requirements of EN 54-3: 2001 with the following tones:
i) Continuous, 990Hz
ii) Warble, 990Hz for 250ms and 730Hz for 250ms
4) The CO functionality is not included within the scope of this approval
Analogue addressable multisensor and CO detector with indoor sounder and short circuit
isolator (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02
bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets rhe requirements of EN 54-7: 2000 at the medium and low sensitivity settings
3) Meets the requirements of EN 54-3: 2001 with the following tones:
i)
Continuous, 990Hz
ii)
Warble, 990Hz for 250ms and 730Hz for 250ms
iii)
Dutch Whoop, 500-1500Hz over 3s
4) The CO functionality is not included within the scope of this approval
Analogue addressable multisensor and CO detector with indoor sounder, short circuit
isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-07502 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
3) Meets the requirements of EN 54-3: 2001 with the following tones:
i)
Continuous 990Hz
ii)
Warble, 990Hz for 250ms and 730Hz for 250ms
4) The CO and beacon functionality are not included within the scope of this approval
Analogue addressable multisensor and CO detector with talking indoor sounder short
circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
201x/05
201x/06
201y/01
201z/01
201z/02
201z/03
201z/04
333
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
6000PLUS/OPHTCO/TSLX
LPCB Ref.
No.
3) Meets the requirements of EN 54-3: 2001 with the following tones:
i)
Continuous, 990Hz
ii)
Warble, 990Hz for 250ms and 730Hz for 250ms
iii)
Bell, 800Hz
iv)
Voice message, F_EVAC2: Female voice evacuation message V2,
Attention, attention. This is an emergency. Please leave the building by the nearest
available exit.
4) The CO and beacon functionality are not included within the scope of this approval
Analogue addressable multisensor and CO detector with talking indoor sounder, short
circuit isolator and beacon (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01
and N28-075-02 bases)
Notes:
1) Meets the requirements of EN 54-5: 2000 at Class A2
2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings
3) Meets the requirements of EN 54-3: 2001 with the following tones:
i)
Continuous, 990Hz
ii)
Warble, 990Hz for 250ms and 730Hz for 250ms
iii)
Dutch Whoop, 500-1500Hz over 3s
iv)
Bell, 800Hz
4) The CO and beacon functionality are not included within the scope of this approval
201z/05
Bases:
3000/BASE standard base
6000/BASE standard low profile base
6000/DIB isolator base
6000PLUS/BASE, standard mounting base
6000PLUS/FFBASE, recessed mounting base
N28-075-01, Plug and Play Fast Fix base
N28-075-02, Plug and Play Surface base
Ravel Electronics Ltd
Unit 11, Chancel Industrial Estate, Newhall Street, Willenhall WV13 1NX, United Kingdom
Tel: 0845 835 8855
E-mail: [email protected]
Certificate No: 512a-(cl-7) to EN54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
RE-336S
LPCB Ref.
No.
512a/02
Conventional 2 wire photoelectric smoke detector with remote LED output (RE-334B
base)
Base
RE-334B 4-wire detector base
Certificate No: 512b-(cl-4) to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA4021: 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
RE-336SH
Conventional 2 wire photoelectric smoke and heat detector with remote LED output (RE334B base)
LPCB Ref.
No.
512b/02
Base
RE-334B
4-wire detector base
Certificate No: 512d-(cl-7) to EN54-5: 2000 + A1: 2002
334
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Heat Detectors
Certificated Products
RE-336H
Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
with LED output (RE-332B base)
LPCB Ref.
No.
512d/04
Base
RE-332B
2-wire detector base
Safety Hi-Tech Srl
Via Cavour, 96 - 67051 Avezzano (AQ), Italy
Tel: +39 0863 1940720 • Fax: +39 0863 1940724
E-mail: [email protected] • Website: www.safetyhitech.com
Certificate No: 010p-(cl-3) to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
SHD90003
SHD90004
Venator-DE Heat Detectorand SHB90002 mounting base)
Note: 1. Meets the requirements of EN54: Part 5 - Class A1R
Venator-DE Heat Detectorand SHB90002 mounting base)
Note: 1. Meets the requirements of EN54: Part 5 - Class CS
LPCB Ref.
No.
010p/05
010p/14
Base:
SHB90001 Venator-DE standard mounting base
SHB90002 Venator-DE standard relay mounting base
Certificate No: 010q-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
SHD90001
SHD90002
Venator-DE Ionisation Smoke Detectorand SHB90002 mounting base)
Venator -DE Optical Smoke Detectorand SHB90002 mounting base)
LPCB Ref.
No.
010q/05
010q/11
Base:
SHB90001 Venator-DE standard mounting base
SHB90002 Venator-DE standard relay mounting base
Safex Fire Services Limited
202 Dhanraj Industrial Estate, Sun Mill Road, Lower Parel West, Mumbai-400 013, India
Tel: +91-22-24938108 • Fax: +91-22-24950224
E-mail: [email protected] • Website: www.safexfire.com
Certificate No: 506a-(cl-2) to EN 54-7 : 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
SF-871
Conventional photoelectric smoke detector (AHMB-L Base)
LPCB Ref.
No.
506a/01
Bases
AHMB-L mounting base
Certificate No: 506b-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 ,EN 54-5: 2000 + A1: 2002 , CEA 4021: 2003
20 Oct 2014
335
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Multi-Criteria Detectors
Certificated Products
SF-0315-2
SF-0315-3
SF-0315-4
(2 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base)
(3 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base)
(4 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base)
LPCB Ref.
No.
506b/01
506b/02
506b/03
Bases
AHMB-031 mounting base
Sareme UAB
Naugarduko str. 32/2, Vilnius LT2006, Lithuania
Tel: +3705 2135047 • Fax: +3705 2333567
E-mail: [email protected]
Certificate No: 512d to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
EA323-2
EA323-4
Conventional 2 wire 24 VDC class A2S fixed temperature and rate-of-rise heat detector
(P/N854001 base)
Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector
(P/N854001 base)
LPCB Ref.
No.
512d/01
512d/05
Bases:
P/N854001 4-Wire detector base
Certificate No: 512a to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
EA-318-2
EA-318-4-12
Conventional 2 wire photoelectric smoke detector (P/N852001 base)
Conventional 4 wire photoelectric smoke detector (P/N854001 base)
LPCB Ref.
No.
512a/01
512a/03
Bases:
P/N852001 2-wire detector base
P/N854001 4-wire detector base
Certificate No: 512b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 +A1: 2002 + A2: 2006 and CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
EA-318-2H
EA-318-2H-LED
Conventional 2 wire photoelectric smoke and heat detector (P/N852001 base)
Conventional 2 wire photoelectric smoke and heat detector with remote LED output
(P/N854001 base)
LPCB Ref.
No.
512b/01
512b/02
Bases:
P/N854001 4-wire detector base
P/N852001 2-wire detector base
336
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Schlumberger Oilfield UK PLC, Sensor Highway Limited (Schlumberger,
Southampton)
Unit 7, The Quadrangle, Abbey Park Industrial Estate, Romsey, Southampton, Hampshire SO51 9DL, United
Kingdom
Tel: +44 (0)1794 529600 • Fax: +44 (0)1794 514931
E-mail: [email protected] • Website: www.slb.com
Certificate No: 648c to LPCB Test Schedule E120656/1.0
Linear Heat Detection System
Certificated Products
Sensa DTS240SC
Distributed Temperature Sensor
SC: Single Channel
Notes:
1. Approval is conditional on the following:
LPCB Ref.
No.
648c/01
- The use of SensorLine II or SensorTube II optical fibres (Stainless Steel).
- The optical fibre lengths should not exceed 4km.
- The system should be installed and configured in accordance with the manufacturers
instructions.
- The zone/alarm configuration parameters should be set in accordance with the
manufacturers instructions
for an alarm response equivalent to Class A1R as specified in EN 54-5: 2000 + A1: 2002.
Sensa DTS240TC
2. The product is known as the LTS240SC when supplied in a wall-mount or rack-mount
housing.
Distributed Temperature Sensor
TC: Twin Channel
648c/01
Notes:
1. Approval is conditional on the following:
- The use of SensorLine II or SensorTube II optical fibres (Stainless Steel).
- The optical fibre lengths should not exceed 4km.
- The system should be installed and configured in accordance with the manufacturers
instructions.
- The zone/alarm configuration parameters should be set in accordance with the
manufacturers instructions
for an alarm response equivalent to Class A1R as specified in EN 54-5: 2000 + A1: 2002.
2. The product is known as the LTS240TC when supplied in a wall-mount or rack-mount
housing.
Annex
Sensor Highway Ltd. is part of Schlumberger Oilfield UK PLC and known as Schlumberger, Southampton
Shenzhen Heiman Technology Co Ltd
No 84 Fuqian Road, Yuexingwei Community, Guanlan, Longhua New District, Shenzhen 518110, China
Tel: +86 75584193930 x8018
E-mail: [email protected]
Certificate No: 1138a to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
HM-612PC-4
HM-612PC-2
HM-613PC-4
HM-613PC-2
20 Oct 2014
Conventional 4-WIRE photoelectric smoke detector with relay output (B-01 base)
Conventional 2-WIRE photoelectric smoke detector with remote LED (B-01 base)
Conventional 4-WIRE photoelectric smoke detector with relay output (B-01 base)
Conventional 2-WIRE photoelectric smoke detector with remote LED (B-01 base)
LPCB Ref.
No.
1138a/01
1138a/02
1138a/03
1138a/04
337
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Base
B-01 Standard base
SHIELD FIRE, SAFETY AND SECURITY LTD
Redburn House, 2a Tonbridge Road, Romford, Essex RM3 8QE, United Kingdom
Tel: +44 207 712 1610 • Fax: +44 207 712 1578
E-mail: [email protected] • Website: www.shieldglobal.com
Certificate No: 548k-(cl-4) to EN 54-12: 2002
Beam Detectors
Certificated Products
D-A430/R
Intelligent optical beam detector
Notes:
1) Meets the requirements of EN 54-12 at the following sensitivity settings:
Level 1 - 1.61 dB
Level 2 - 2.31dB
LPCB Ref.
No.
548k/01
Certificate No: 548d-(cl-4) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
D-C401
D-A411
Conventional photoelectric smoke detector (DZ-03 base)
Intelligent photoelectric smoke detector (DZ-03 base)
LPCB Ref.
No.
548d/01
548d/02
Bases:
DZ-03 Standard detector base
Certificate No: 548c-(cl-4) to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
D-C402
D-A412
Conventional Class A1R heat detector (DZ-03 base)
Intelligent Class A1R heat detector (DZ-03 base)
LPCB Ref.
No.
548c/01
548c/02
Bases:
DZ-03 Standard detector base
Certificate No: 548q-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA 4021: 2003
Certificated Products
D-C400
D-A410
Conventional Optical Smoke and Heat Multisensor Detector
(DB-CA Base, DZ-03D Base & DZ-03 Base)
Notes:
1. Meets the requirements of EN 54-7: 2000 at sensitivity setting Mode 1
2. Meets the requirements of EN 54-5: 2000 at Class A2R
Intelligent Optical Smoke and Heat Multisensor Detector
(DZ-03 Base)
Notes:
1. Meets the requirements of EN 54-7:2000 at sensitivity setting Mode 1
2. Meets the requirements of EN 54-5: 2000 at Class A2R
LPCB Ref.
No.
548q/01
548q/02
Bases
DB-CA Active EOL Unit
DZ-03D Diode Base
DZ-03
Standard Base
338
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Siemens Switzerland Limited, Building Technologies Division
International Headquarters, Gubelstrasse 22, CH-6301 Zug, Switzerland
Tel: +41 (0) 41 724 24 24 • Fax: +41 (0) 41 724 35 22
Manufacturing at:
Volketswil Factory, Industriestrasse 22, CH-8604 Volketswil, Switzerland
Tel: +41 1 922 6111 • Fax: +41 1 922 6450
UK Sales:
Siemens Building Technologies Limited, FSP Division
Tel: +44 (0)1784 461616 • Fax: +44 (0)1784 464646
Certificate No: 126x-(cl-1) to EN 54:7: 2000 + A1:2002 + A2:2006
Certificate No: 126ab-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Certificate No: 126am-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005
Certificate No: 531c-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 531d-(cl-1) to EN 54-7:2000 + A1:2002 + A2: 2006, EN 54-17: 2005 and CEA4021: 2003-07
Certificate No: 531e-(cl-1) to EN 54-7: 2000 + A1: 2002 + A1: 2006 and EN 54-17: 2005
Certificate No: 1161a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 1161b-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005
Point Smoke Detectors
Certificated Products
DO1101A
DO1101A-Ex
DO1151A
DOT1151A
DOT1151A-Ex
DO1131A
DO1152A
DOT1131A
DOT1152A
FDO241
FDO221
DO1131A
DO1152A
DOT1131A
DOT1152A
20 Oct 2014
Conventional photoelectric smoke detector (DB1101A base)
Intrinsically safe conventional photoelectric smoke detector (DB1101A base)
Addressable photoelectric smoke detector (DB1151A base)
Note: Meets EN54-7 at Personen/life sensitivity settings
Addressable photoelectric smoke detector with thermal enhancement (DB1151A base)
Note: Meets EN54-7 at Personen/life sensitivity and Immobilien/property sensitivity
settings
Intrinsically safe conventional photoelectric smoke detector with thermal enhancement
(DB1151A base)
Note: Meets EN54-7 at Personen/life sensitivity and Immobilien/property sensitivity
settings
Addressable photoelectric smoke detector with short circuit isolator (DB1131A base)
Note: Meets EN54-7:2000 at standard and high sensitivity Settings
Addressable photoelectric smoke detector with short circuit isolator (DB1151A base)
Note: Meets EN54-7:2000 at Personen/life sensitivity and Immobilien/property sensitivity
settings
Addressable photoelectric smoke detector with thermal enhancement and short circuit
isolator (DB1131A base)
Note: Meets EN54-7:2000 at standard and high sensitivity Settings
Addressable photoelectric smoke detector with thermal enhancement and short circuit
isolator (DB1151A base)
Note: Meets EN54-7:2000 at Personen/life sensitivity and Immobilien/property sensitivity
settings
Analogue addressable photoelectric smoke detector with short circuit isolator
(FDB221, FDB201, FDB291 and FDB292 bases)
Analogue addressable photoelectric smoke detector with short circuit isolator
(FDB221, FDB201, FDB291 and FDB292 bases)
Addressable photoelectric smoke detector with short circuit isolator (DB1131A base)
Note:
1. Meets EN54-7: 2000 at Standard and High sensitivity settings
Addressable photoelectric smoke detector with short circuit isolator
(DB1151A base)
Note:
1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings
Addressable photoelectric smoke detector with thermal enhancement and short circuit
isolator (DB1131A base)
Note:
1. Meets EN54-7: 2000 at Standard and High sensitivity settings
Addressable photoelectric smoke detector with thermal enhancement and short circuit
isolator (DB1151A base)
LPCB Ref.
No.
1161a/01
1161a/02
1161a/03
1161a/04
1161a/05
1161b/01
1161b/02
1161b/03
1161b/04
126ab/01
126ab/02
126am/03
126am/05
126am/06
126am/09
339
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
R970
DO1101A
DO1101A-Ex
DO1151A
DOT1151A
DOT1151A-Ex
OH320C
OP320C
OH620
OP620
OP820
OH720
OP720
OH320A
OP320A
LPCB Ref.
No.
Note:
1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings
Scattered light smoke detector (Z94 base)
Note:
1. Meets requirements of EN54-7 at standard (2.5%/m) and increased (1.7%/m)
sensitivity setting
Conventional photoelectric smoke detector
(DB1101A base)
Intrinsically safe conventional photoelectric smoke detector
(DB1101A base)
Addressable photoelectric smoke detector
(DB1151A base)
Note:
1. Meets EN54-7 at Personen/life sensitivity settings
Addressable photoelectric smoke detector with thermal enhancement
(DB1151A base)
Note:
1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings
Intrinsically safe addressable photoelectric smoke detector with thermal enhancement
(DB1151A base)
Note:
1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings
Conventional photoelectric smoke detector with thermal enhancement (SO320 base)
Conventional photoelectric smoke detector (SO320 base)
Analogue addressable photoelectric smoke detector with thermal enhancement
(SO620 base)
Note: Meets the requirements of EN54-7: 2000 at Standard and High sensitivity settings
Analogue addressable photoelectric smoke detector (SO620 base)
Note: Meets the requirements of EN54-7: 2000 at Standard and High sensitivity settings
Analogue addressable photoelectric smoke detector (SO820 base)
Note: Meets the requirements of EN54-7: 2000 at Personen/life and Immobilien/property
sensitivity settings
Analogue addressable multi sensor smoke detector
(DB720, DB721 bases)
Note:
1. Meets the requirements of EN 54-7 in the following sensitivities:
1 - Robust 3.5%/m
2 - Sensitive 2.5%/m
Analogue addressable smoke detector with short circuit isolator (DB720, DB721 bases)
Note:
1. Meets the requirements of EN 54-7 in the following sensitivities:
1 - Standard 2.5%/m
2 - Sensitive 1.8%/m
Analogue addressable photoelectric smoke detector with thermal enhancement and short
circuit isolator (SO320 base)
Note:
1. Meets EN54-7: 2000 at Standard and High sensitivity settings
Analogue addressable photoelectric smoke detector with short circuit isolator
(SO320 base)
Note:
1. Meets EN54-7: 2000 at Standard and High sensitivity settings
126x/01
126x/02
126x/03
126x/04
126x/05
126x/06
531c/02
531c/04
531c/05
531c/06
531c/07
531d/01
531e/01
531e/02
531e/03
Bases:
Z94 base
FDB221 base
FDB201 base "Collective"
FDB291 base attachment surface
FDB292 base attachment surface wet
DB720 Detector base
DB721 Detector base with loop contact
DB1101A base
DB1131A base
DB1151A base
DBZ1191 base attachment
SO620 Analogue addressable (AnalogPLUS) detector base
SO820 Analogue addressable (Interactive) detector base
SO320 base for SynovaTM 300 series detectors
DB1101A base
Base for collective fire detectors
DB1151A base
Base for interactive fire detectors
DB1131A base
Base for analogPLUS fire detectors
340
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 126aa-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005
Certificate No: 126an-(cl-1) to EN 54-5: 2000 + A1: 2002
Certificate No: 531b-(cl-1) to EN 54-5: 2000 + A1: 2002
Certificate No: 531f-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005
Certificate No: 126av-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005
Certificate No: 1161c-(cl-1) to EN 54-5: 2000 + A1: 2002
Certificate No: 1161d-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005
Point Heat Detectors
Certificated Products
DT1101A
DT1101A-Ex
DT1102A
DT1102A-Ex
DT1151A-Ex
DT1131A
DT1152A
FDT241
FDT221
DT1101A
DT1101A-Ex
DT1102A
DT1102A-Ex
DT1151A-Ex
DT1131A
DT1152A
HI320C
HI322C
HI620
HI820
HI720
HI722
HI320A
HI322A
Conventional class A1R heat detector (DB1101A base)
Conventional intrinsically safe class A1R heat detector (DB1101A base)
Conventional class B heat detector (DB1101A base)
Conventional intrinsically safe class B heat detector (DB1101A base)
Analogue addressable intrinsically safe heat detector (DB1151A base)
Note: Meets EN54-5: 2000 at class A1R and class B
Analogue addressable class A1R heat detector with short circuit isolator (DB1131A base)
Analogue addressable heat detector with short circuit isolator (DB1151A base)
Note: Meets EN54-5: 2000 at class A1R and class BS
Analogue addressable rate of rise heat detector with short circuit isolator.
(FDB221, FDB201, FDB291 and FDB292 bases)
Note: Meets EN 54-5: 2000 at Class A1R, A1S, BR and BS.
Analogue addressable rate of rise heat detector with short circuit isolator (FDB221,
FDB201, FDB291 and FDB292 bases)
Note: Meets EN 54-5: 2000 at Class A1R and BR
Conventional class A1R heat detector (DB1101A base)
Conventional intrinsically safe class A1R heat detector (DB1101A base)
Conventional class B heat detector (DB1101A base)
Conventional intrinsically safe class B heat detector (DB1101A base)
Analogue addressable intrinsically safe heat detector (DB1151A base)
Note: Meets EN54-5: 2000 at class A1R and class B
Analogue addressable class A1R heat detector with short circuit isolator
(DB1131A base)
Analogue addressable heat detector with short circuit isolator
(DB1151A base)
Note:
1. Meets EN 54-5:2000 at class A1R and class BS
Conventional class A1R heat detector (SO320 base)
Conventional class A2 heat detector (SO320 base)
Analogue addressable (AnalogPLUS) Class A1R heat detector (SO620 base)
Analogue addressable (Interactive) heat detector (SO820 base)
Note: Meets the requirements of EN54-5: 2000 at class A1R and class BR
Analogue addressable class A2S and A2R heat detector with short circuit isolator
(DB720, DB721 bases)
Notes:
1. Meets the requirements of EN 54-5 at classes A2S and A2R
Analogue addressable class A2S heat detector with short circuit isolator
(DB720, DB721 bases)
Notes:
1. Meets the requirements of EN 54-5 at class A2S
Analogue addressable class A1R heat detector with short circuit isolator (SO320 base)
Analogue addressable class A2 heat detector with short circuit isolator (SO320 base)
LPCB Ref.
No.
1161c/01
1161c/02
1161c/03
1161c/04
1161c/05
1161d/01
1161d/02
126aa/01
126aa/02
126an/01
126an/02
126an/03
126an/04
126an/06
126av/01
126av/02
531b/03
531b/04
531b/05
531b/06
531f/01
531f/02
531f/03
531f/04
Bases:
Z94 base
DFB1190 base
FDB221 base
FDB201 base “Collective”
FDB291 base attachment surface
FDB292 base attachment surface wet
DB720 Detector base
DB721 Detector base with loop contact
DB1101A base for conventional addressing
DB1131A base for analogue addressing
DB1151A base for interactive fire detectors
SO320 base for SynovaTM 300 series detectors
SO620 Analogue addressable (AnalogPLUS) detector base
SO820 Analogue addressable (Interactive) detector base
DB1101A Base for collective fire detectors
DB1151A Base for interactive fire detectors
20 Oct 2014
341
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
DB1131A Base for analogPLUS fire detectors
Certificate No: 126ag-(cl-1) to EN 54-12: 2002 and EN 54-17: 2005
Certificate No: 126ak-(cl-1) to EN 54-12: 2002 and EN 54-17: 2005
Beam Detectors
Certificated Products
FDL241-9
DLO1191
LPCB Ref.
No.
126ag/01
Analogue addressable beam detector with short circuit isolator (FDLB291 base)
Note: Certified at sensitivity settings 30%, 50% and 65%
Optical beam smoke detector with short circuit isolator (DLB1191A base)
Note:
1. Certified at sensitivity setting 30%, 50% and 65%
126ak/01
Bases:
FDLB291 base
DLB1191A base
Certificate No: 126bb to EN 54-10: 2002 + A1: 2005
Certificate No: 126af-(cl-1) to EN 54-10: 2001 + A1: 2005 and EN 54-17: 2005
Certificate No: 126bc to EN 54-10: 2002 + A1: 2005 and EN 54-17: 2005
Flame Detectors
Certificated Products
DF1192
DF1151-Ex
DF1191
DF1192
FDF221-9
FDF241-9
DF1101-Ex
LPCB Ref.
No.
126bb/01
Analogue Addressable Infra Red Flame Detector (DFB 1190 base)
Note:
Certified to EN 54-10:2002 + A1: 2005 at Class 1 and 2
Analogue Addressable IS Infra Red Flame Detector with Short Circuit Isolator
(DFB1190 Base)
Note:
1. Certified to EN 54-10: 2002 + A1: 2005 at Class 1 and 2
Analogue Addressable Infra Red Flame Detector with Short Circuit Isolator
(DFB1190 Base)
Note:
1. Certified to EN 54-10: 2002 + A1: 2005 at Class 1 and 2
Analogue Addressable Infra Red Flame Detector with Short Circuit Isolator
(DFB1190 Base)
Note:
1. Certified to EN 54-10: 2002 + A1: 2005 at Class 1 and 2
Analogue Addressable Infra Red Flame Detector with Short Circuit Isolator (FDFB291
base)
Note:
1. Certified to EN 54-10: 2002 + A1: 2005 at Class 1 and 2
Analogue Addressable Infra Red Flame Detector with Short Circuit Isolator (FDFB291
base)
Note:
1. Certified to EN 54-10: 2002 + A1: 2005 at Class 1 and 2
Conventional I.S. infra red flame detector (DFB 1190 base)
Note:
1. Certificated in "increased" & "standard" sensitivity settings - Class 1 and 2
respectively.
126bc/01
126bc/02
126bc/03
126bc/04
126bc/05
126s/03
Bases:
Z94 base
DFB 1190 base
FDFB291 base
Certificate No: 126ah-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003 and EN 54-17: 2005
Certificate No: 126ba-(cl-1) to EN 54-5: 2001 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003
Multi-criteria Detectors
Certificated Products
FDOOT241-9
342
Analogue addressable multisensor detector with short circuit isolator (FDB201, FDB202,
FDB221, FDB222, FDB291 and FDB293 bases)
Note:
Meets the requirements of EN 54-5: 2000 at
LPCB Ref.
No.
126ah/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
FDOOTC241
LPCB Ref.
No.
Class A2R & A2S and EN 54-7: 2000 at sensitivity settings:
Parameter No. 1
Universal
Parameter No. 2
Robust with thermal enhancement
Parameter No. 3
Sensitive
Parameter No. 4
Balanced with thermal enhancement
Parameter No. 5
Suppression with thermal enhancement
Parameter No. 6
Response with thermal enhancement
Parameter No. 7
Robust / BGD with thermal enhancement
Analogue addressable multisensor detector with short circuit isolator
(FDB221, FDB222, FDSB291 & FDSB293 bases)
Note - the following modes are approved
Mode 0 - Neural Fire Detector:
0.0) High Compensation
0.2) Robust
0.4) Balanced
0.5) Suppression
0.6) Fast Response
0.7) High Compensation
0.9) High Sensitive Fast
0.10) Balanced CO
0.12) Suppression CO
126ah/03
Mode 1 - Heat Detector
1.1) A1R
1.2) BR
1.3) A1S
1.4) BS
FDOOT241-A3
Mode 2 - Smoke Detector
2.0) Universal
2.1) Universal
2.2) Robust
2.3) Sensitive
Multisensor detector with short circuit isolator (FDB221, FDB222, DB1131A, FDB291,
FDB293 and FDB241 bases)
Notes: - the following modes are approved
126ah/04
1 - Parameter sets for detection when connected to FDnet communication protocol
Mode 0 - Neural Fire Detector-Multisensor Detector:
No
Parameter
Robust
2
Balanced
4
Suppression
5
Fast Response
6
High Compensation
7
High Sensitive Fast
9
Mode 1 - Heat Detector:
Parameter
A1R
BR
A1S
BS
No
1
2
3
4
Mode 2 - Smoke Detector:
Parameter
Universal
Robust
Sensitive
No
1
2
3
2 - Parameter sets for detection when connected to AnalogPLUS communication protocol
Smoke only as DO1131A
Parameter
Sensitive
Universal Fast
No
3
4
Smoke with heat enhancement as DOT1131A
Parameter
No
Fast Response
6
Universal Fast
12
20 Oct 2014
343
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
Rate of Rise heat detection as DT1131A
No
Parameter
A1R
1
FDOOT241-A9
Fixed temperature heat detection as DT1132A
Parameter
No
BS
4
Multisensor detector with short circuit isolator (FDB221, FDB222, FDB201, FDB202,
FDB299, FDB291, FDB293, DB1101A and SPF600 bases)
Notes - the following modes are approved
126ah/05
1 - Parameter sets for detection when connected to FDnet communication protocol and
collective detector line
Mode 0 - Neural Fire Detector-Mutisensor Detector:
Parameter
No
Robust
2
Balanced
4
Suppression
5
Fast Response
6
High Compensation
7
High Sensitive Fast
9
Mode 1 - Heat Detector:
Parameter
A1R
BR
A1S
BS
OOH740
No
1
2
3
4
Mode 2 - Smoke Detector:
No
Parameter
Universal
1
Robust
2
Sensitive
3
Analogue addressable multisensor detector with short circuit isolator
(DB720, DB721, DB722, BA720 & DB721D bases)
126ba/01
Notes - the following modes are approved
1 - Parameter sets for detection when connected to C-Net detector line
Mode 0 - Neural Fire Detector:
Parameter
Nr
Robust
2
Balanced
4
Suppression
5
Fast Response
6
High Compensation 7
High Sensitive Fast 9
Mode 1 - Heat Detector:
Parameter
Nr
A1R
1
BR
2
A1S
3
BS
4
Mode 2 - Smoke Detector:
Parameter
Nr
Universal
1
Robust
2
Sensitive
3
2 - Parameter sets for detection when connected to collective detector line
Parameter
Standard Plus
Suppression
High Sensitive Fast
344
Resistor value in detector base
33 Kilo Ohms
68 Kilo Ohms
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
OOHC740
LPCB Ref.
No.
Analogue addressable multisensor detector with short circuit isolator
(DB720, DB721, DB722 & BA720 bases)
126ba/02
Note - the following modes are approved
Parameter sets for detection when connected to C-Net detector line
Mode 0 - Neural Fire Detector:
Nr
Parameter
Robust
2
Balanced
4
Suppression
5
Fast Response
6
High Compensation
7
High Sensitive Fast
9
Bases:
FDB221
FDB201
FDB202
FDB222
FDB291
FDB292
FDB293
DB720
DB721
DB722
DB721D
BA720
DB1131A
FDB241
FDB299
DB1101A
SPF600
Mode 1 - Heat Detector:
Parameter
A1R
BR
A1S
BS
Nr
1
2
3
4
Mode 2 - Smoke Detector:
Parameter
Universal
Robust
Sensitive
Nr
1
2
3
base with stand offs
base “Collective” with stand offs
base “Collective” without stand offs
base without stand offs
base attachment surface
base attachment surface wet
base attachment surface wet
Detector base
Detector base with loop contract
Detector Base with loop contract
Detector Base with snap lock
Base with surface mounted line
Standard base
Standard base for special location
Base
Base
Base
Certificate No: 126az-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005 and CEA 4021: 2003
Multi-Sensor Detectors
Certificated Products
FDOOT221
Analogue addressable multisensor detector with short circuit isolator
(FDB221, FDB222, FDB291 and FDB293 bases)
Note:
1. Meets the requirements of EN 54-7:2000 at sensitivity settings:
Parameter No. 2
Parameter No. 4
LPCB Ref.
No.
126az/01
Robust with thermal enhancement
balanced with thermal enhancement
Bases
FDB221 base with stand offs
FDB222 base without stand offs
FDB291 base attachment surface
FDB293 base attachment surface wet
20 Oct 2014
345
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
SMS (Novar Systems Ltd)
Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United Kingdom
Tel: +44 (0)116 246 2100 • Fax: +44 (0)116 246 2016
Website: www.smsfire.co.uk
Certificate No: 042ak to EN 54-5: 2000 + A1: 20002, EN 54-3: 2001 + A1: 2002, CEA GEI 1-084: Draft 08.08.00, CEA GEI 1-052:
11.06.97 Draft 2.0,
Point Heat Detectors
Certificated Products
SEN-780
SEN-780-ST
S-Quad analogue addressable Class P heat detector with sounder
(S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)
Notes:
1. Meets the requirement of EN 54: Part 5 at the following settings:
State 0 - Class A1
State 5 - Class B
2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings:
High - Contiuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
S-Quad analogue addressable Class P heat detector with sounder and strobe
(S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)
Notes:
1. Meets the requirement of EN 54: Part 5 at the following settings:
State 0 - Class A1
State 5 - Class B
2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings:
High - Contiuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
3. Strobe note included in scope of approval
LPCB Ref.
No.
042ak/01
042ak/03
Bases:
S4-700 standard base
S4-FLUSH semi-flush fixing kit
Certificate No: 042an to EN 54-7: 2000 + A1: 2002, EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002, EN 54-17: 2005, EN 54-18:
2005 and CEA 4021: 2003,
Certificate No: 042bf to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005
Certificate No: 567ac-(cl-1) to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN54-17: 2005, EN54-18: 2005,
EN54-23: 2010
Certificate No: 567j-(cl-1) to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1 :2002, EN 54-7: 2000 + A1: 2002 + A2: 2006,
EN54-17: 2005, EN54-18: 2005,
Certificate No: 567ab-(cl-1) to EN54-3: 2001 + A1: 2002 + A2: 2006, EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006,
EN54-17: 2005, EN54-18: 2005, EN 54-23: 2010,
Certificate No: 567aa-(cl-1) to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005,
Multi Criteria Detectors
Certificated Products
SEN-770
SEN-770-ST
346
S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector
with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)
Notes:
1. Meets the requirement of EN 54-5 and EN 54-7 at the following settings:
State 0 - Medium optical / Class A1 heat
2. Meets the requirements of EN 54-3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector
with sounder and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush
mounting kit)
Notes:
1. Meets the requirement of EN 54- 5 and EN 54-7 at the following settings:
State 0 - Medium optical / Class A1 heat
2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
3. Strobe not included in scope of approval.
LPCB Ref.
No.
042an/04
042an/06
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
SEN-710
SEN-780-S
SEN-770-VAD-HPR
SEN-770-VAD-HPW
SEN-770-VAD-LPW
SEN-780-VAD-HPR
20 Oct 2014
LPCB Ref.
No.
S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector
(S4-700 base with or without S4-FLUSH mounting kit)
Note:
1. Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the
following settings:
State 0 - Medium optical / Class A1 heat
Analogue Addressable Class P Heat Sensor with Sounder (S4-701 base)
Notes:1. Meets the requirements of EN 54-3:2001 at the following sounder tone
settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5:2000 at the following settings:
State 0 - Class A1 heat
State 5 - Class B heat
3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with
Sounder and Red Visual Alarm (S4-701 Base)
Notes:
1. Meets the requirements of EN 54-3 at the following sounder tone settings
High- Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 - Medium Optical / Class A1 Heat
State 5 - Medium Optical / Class B Heat
State 8 - Delayed Medium Optical / Class A1 Heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 5423 for the following
- Category (light pattern details
@ High power setting - (Category C: C-3-14 and Category O: O-4.5-14)
@ Medium power setting - (Category C: C-3-13 and Category O: O-4-13)
@ Low power setting - (Category C: C-3-10 and Category O: None)
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with
Sounder and White Visual Alarm (S4-701 Base)
Notes:
1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High- Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 - Medium Optical / Class A1 Heat
State 5 - Medium Optical / Class B Heat
State 8 - Delayed Medium Optical / Class A1 Heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23
for the following:
- Category (light pattern details)
@ High power setting - (Category C: C-6-16 and Category O: None)
@ Medium power setting - (Category C: C-3-14 and Category O: O-5-14)
@ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with
Sounder and White Visual Alarm (S4-701 Base)
Notes:
1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High- Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 - Medium Optical / Class A1 Heat
State 5 - Medium Optical / Class B Heat
State 8 - Delayed Medium Optical / Class A1 Heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 5423 for the following:
- Category (light pattern details)
@ Low power setting - (Category C: C-3-10 and Category O: None)
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
Analogue Addressable Class P Heat Sensor with Red Visual Alarm and Sounder (S4-701
042bf/01
567aa/01
567ab/01
567ab/02
567ab/03
567ac/03
347
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
Base)
Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 at the following settings:
State 0 - Class A1 heat
State 5 - Class B heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23
for the following:
- Category (light pattern details)
@ High power setting - (Category C: C-3-14 and Category O: O-4.5-14)
@ Medium power setting - (Category C: C-3-13 and Category O: O-4-13)
@ Low power setting - (Category C: C-3-10 and Category O: None)
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
SEN-780-VAD-LPW
Analogue Addressable Class P Heat Sensor with White Visual Alarm and Sounder (S4701 Base)
Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 at the following settings:
State 0 - Class A1 heat
State 5 - Class B heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 54-23
for the following:
- Category (light pattern details)
@ Low power setting - (Category C: C-3-10 and Category O: None)
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
567ac/04
SEN-780-VAD-HPW
Analogue Addressable Class P Heat Sensor with White Visual Alarm and Sounder (S4701 Base)
Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 at the following settings:
State 0 - Class A1 heat
State 5 - Class B heat
3. The ceiling mounted Visual Alarm Device (VAD) meets the requirements of EN 5423:
- Category (light pattern details)
@ High power setting - (Category C: C-6-16 and Category O: None)
@ Medium power setting - (Category C: C-3-14 and Category O: O-5-14)
@ Low power setting - (Category C: C-3-10.8 and Category O: O-4-10.8
- Synchronization
- Flash rate 2 seconds (0.5Hz)
4. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
567ac/05
SEN-770-S
Analogue Addressable Optical Smoke and Class P Heat Multi-Sensor Detector with
Sounder (S4-701 base)
Notes:1. Meets the requirements of EN 54-3 at the following sounder tone settings:
High - Continuous 933 Hz
Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs
2. Meets the requirements of EN 54-5 and EN 54-7 at the following settings:
State 0 -Medium optical / Class A1 heat
3. Must be used with the S4-701 base and IP seal plate in order to achieve IP21C
567j/08
Bases:
S4-700 standard base
S4-701 S4 Quad Plate and Base
S4-FLUSH Semi-flush fixing kit
Certificate No: 042be to EN54-5: 2000 + A1: 2002, EN54-17: 2005, EN54-18: 2005
Certificate No: 042bd to EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005
348
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Point Smoke Detectors
Certificated Products
SEN-715
S-Quad analogue addressable optical smoke detector
(S4-700 base with or without S4-FLUSH mounting kit)
Note:
1. Meets the requirements of EN 54: Part 7 at the following settings:
State 0 - Medium optical
SEN-720
S-Quad analogue addressable
Class P heat detector
(S4-700 base with or without S4-FLUSH mounting kit)
Note:
1. Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the
following settings:
State 0 - Class A1 heat
LPCB Ref.
No.
042bd/01
042be/01
Bases:
S4-700 standard base
S4-FLUSH semi-flush fixing kit
Sterling Safety Systems
Unit B12a, Holly Farm Business Park, Honiley, Warwickshire CV8 1NP, United Kingdom
Tel: +44(0)1926485282 • Fax: +44(0)1926485090
E-mail: [email protected] • Website: www.sterlingsafety.co.uk
Certificate No: 928a to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005
Certificate No: 928d to EN 54-5: 2000 + A1: 2002
Certificate No: 928j-(cl-6) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008
Point Heat Detectors
Certificated Products
HFI-TA-01
HFI-TAE-01
HFW-TA-01
Bases
HFI-UB-01
HFI-DUB-01
HFI-DMB-01
HFI-DDB-01
HFI-UBS-01
HFI-DUBS-01
HFI-DMBS-01
HFI-DDBS-01
WAB100
Analogue addressable Class P heat detector with short circuit isolator
(HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B
Analogue addressable Class P heat detector lite
(HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases)
Note:
1. Meets the requirements of EN 54-5 for Class A1R and Class B
Wireless heat detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1R
2. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928a/01
928d/01
928j/01
Universal adaptor base
Deep adaptor base
Vega adaptor base
Vega deep adaptor base
Universal adaptor base with shorting clip
Deep adaptor base with shorting clip
Vega adaptor base with shorting clip
Vega deep adaptor base with shorting clip
Wireless Adaptor Base
Certificate No: 928b to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Certificate No: 928e to EN 54-7: 2000 + A1: 2002 + A2: 2006
20 Oct 2014
349
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Point Smoke Detectors
Certificated Products
HFI-PA-01
Analogue addressable photoelectric smoke detector with short circuit isolator
(HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases)
Note:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Analogue addressable photoelectric smoke detector lite
(HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases)
Note:
1. Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
HFI-PAE-01
Bases
HFI-UB-01
HFI-DUB-01
HFI-DMB-01
HFI-DDB-01
HFI-UBS-01
HFI-DUBS-01
HFI-DMBS-01
HFI-DDBS-01
LPCB Ref.
No.
928b/01
928e/01
Universal adaptor base
Deep adaptor base
Vega adaptor base
Vega deep adaptor base
Universal adaptor base with shorting clip
Deep adaptor base with shorting clip
Vega adaptor base with shorting clip
Vega deep adaptor base with shorting clip
Certificate No: 928c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003
Certificate No: 928f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003
Multi-Sensor Detectors
Certificated Products
HFI-MA-01
HFI-MAE-01
350
Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with
short circuit isolator
(HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases)
Notes:
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:
Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
Multi Criteria Level 2 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 3 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
3. Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Analogue addressable Class P heat and photoelectric smoke multi-sensor detector lite
HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFI-DMBS-01 and
HFI-DDBS-01 bases)
Notes:
1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:
Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
Multi Criteria Level 2 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 3 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke
LPCB Ref.
No.
928c/01
928f/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
detection with Class A1 heat response
2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:
Class A1R heat only response
3. Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Bases
HFI-UB-01
HFI-DUB-01
HFI-DMB-01
HFI-DDB-01
HFI-UBS-01
HFI-DUBS-01
HFI-DMBS-01
HFI-DDBS-01
Universal adaptor base
Deep adaptor base
Vega adaptor base
Vega deep adaptor base
Universal adaptor base with shorting clip
Deep adaptor base with shorting clip
Vega adaptor base with shorting clip
Vega deep adaptor base with shorting clip
Certificate No: 928k-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008
Smoke Detectors
Certificated Products
HFW-PA-01
Bases:
WAB100
Wireless optical smoke detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-7 in the normal sensitivity setting
2. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928k/01
Wireless Adaptor Base
Certificate No: 928m-(cl-6) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
HFW-MA-01
Bases:
WAB100
20 Oct 2014
Wireless multi-criteria detector (WAB100 base)
Notes:
1. Meets the requirements of EN 54-5 for Class A1
2. Meets the requirements of EN 54-7 in the normal sensitivity setting
3. The device must be used with the following batteries only:
 CR123A (3 Vdc) - main battery

CR2032A (3 Vdc) - secondary battery
LPCB Ref.
No.
928m/01
Wireless Adaptor Base
351
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
System Sensor
3825 Ohio Avenue, Saint Charles, Illinois 60174, USA
Tel: +1 630 377 6580 • Fax: +1 630 377 7245
Website: www.systemsensor.com
European Sales Enquiries:
System Sensor Europe
Tel: +44 (0)1403 891920 • Fax: +44 (0)1403 891921
Certificate No: 118h to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
7251
Analogue addressable photoelectric laser smoke detector (B501, B501AP, B501DG,
B524IEFT, B524IEFT-1 bases)
Note: meets requirements of EN 54: Part 7 at sensitivities 7 to 9 inclusive
LPCB Ref.
No.
118h/01
Bases:
B501 analogue sensor base
B501AP intelligent detector base
B501DG deep base
B524IEFT short circuit isolator base
B524IEFT-1 short circuit isolator base
System Sensor Europe
KAC House, Thornhill Road, North Moons Moat, Redditch, Worcestershire B98 9ND, United Kingdom
Tel: +44 (0)1527 406700 • Fax: +44 (0)1527 406699
Website: www.systemsensoreurope.com
Certificate No: 118h to EN54-7: 2000
Certificated Products
LZR-1M
Analogue addressable photoelectric laser smoke detector (B501, B501DG, B524IEFT,
B524IEFT-1 bases)
Note: meets requirements of EN 54: 7 at sensitivities 7 to 9 inclusive
LPCB Ref.
No.
118h/01
Bases
B501DG deep base
B524IEFT short circuit isolator base
B524IEFT-1 short circuit isolator base
System Sensor, Honeywell International (I) PVT. Limited
Sector 36, Pace City - II, Gurgaon - 122 004, Haryana, India
Tel: +91 124 4752700 • Fax: +91 124 4752750
E-mail: [email protected]
Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 550d to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Smoke Detectors
Certificated Products
2351E
352
Conventional photoelectric smoke detector
LPCB Ref.
No.
550a/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
EC01003
FL/1003
2251EM
22051E-xx-yy
2FA51
22051EI-xx-yy
LPCB Ref.
No.
(B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 &
B401DGSD bases)
Note: Meets the requirements of EN54-7:2000 at low, medium & high sensitivity settings.
Conventional photoelectric smoke detector (ECO1000B, ECO1000BSD, ECO1000BR,
ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 &
ECO1000BR1000SD bases)
Conventional photoelectric smoke detector
(FL/1000B base)
Analogue addressable optical smoke detector (B501, B501DG and B5241EFT-1 bases)
Notes : Meets EN 54-7 with low, medium and high sensitivity settings
Analogue addressable optical smoke detector
(B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)
Notes:
1) xx = (Range 0-99) ~ indicates the communication software protocol
2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
3) meets the requirements of EN 54-7: 2000 at high and low sensitivity
Conventional photoelectric smoke detector (BFA1 base)
Analogue addressable optical smoke detector with short circuit isolator (B501AP,
B524HTR and B524RTE bases)
Notes:
1) xx = (Range 0-99) ~ indicates the communication software protocol
2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
3) Meets the requirements of EN 54-7: 2000 at high and low sensitivity
550a/02
550a/02
550a/03
550a/04
550a/05
550d/01
Bases:
B401 standard base
B401DG deep base
B401R standard base with schottky diode
B401SD standard base with schottky diode
B401RSD standard base with 470 ohm resistor and schottky diode
B401R1000 standard base with 1000 ohm resistor
B401DGR deep base with 470 ohm resistor
B401DGR1000 deep base with 1000 ohm resistor
B401DGSD deep base with schottky diode
ECO1000B standard base
ECO1000BSD standard base with schottky diode
ECO1000BR standard base, 470 ohm resistor
ECO1000BRSD standard base, 470 ohm resistor and schottky diode
ECO1000BR680 standard base, 680 ohm resistor
ECO1000BR680SD standard base, 680 ohm resistor and schottky diode
ECO1000BR1000 standard base, 1000 ohm resistor
ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode
B501 standard analogue detector base
B501DG deep analogue detector base
FL/B401 standard base
FL/1000B standard base
B501AP intelligent detector base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
BFA1 standard base
Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Certificate No: 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 & CEA 4021: 2003
Multi Criteria Detectors
Certificated Products
2351TEM
ECO1002
FL/1002
20 Oct 2014
Conventional optical/thermal detector
(B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 &
B401DGSD bases)
Note: Meets the requirements of EN54-5:2000 at Class A1R and EN54-7:2000 at low,
medium & high sensitivity settings.
Conventional photo-thermal detector
(ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680,
ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases)
Note: Meets the requirements of EN 54-5:2000 at class A1R at pre-set sensitivity.
Conventional optical/thermal detector
base)
Notes: Meets the requirements of EN54-5 at class A1R at pre-set sensitivity
LPCB Ref.
No.
550b/01
550b/02
550b/02
353
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
2251TEM
22051TLE-xx-yy
22051TE-xx-yy
2FA51T
22051TLEI-xx-yy
22051TEI-xx-yy
LPCB Ref.
No.
Analogue optical/thermal smoke & heat detector (B501, B501DG and B5241EFT-1
bases)
Notes :
1) Meets the requirements of EN 54-7: 2000 at sensitivity settings 1 to 5
2) Meets the requirements of EN 54-5: 2000 at Class A1R
Analogue addressable photo-thermal-IR multi-criteria detector
(B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)
Notes:
1) xx = (Range 0-99) ~ indicates the communication software protocol
2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
3) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria detector
(B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)
Notes:
1) xx = (Range 0-99) ~ indicates the communication software protocol
2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
3)Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Conventional photo-thermal class A1R detector (BFA1 base)
Note: Meets the requirements of EN54-5: 2000 class A1R at pre-set sensitivity
Analogue addressable photo-thermal-IR multi-criteria smoke detector with short circuit
isolator (B501AP, B524HTR and B524RTE bases)
Notes:
1) xx = (Range 0-99) ~ indicates the communication software protocol
2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
3) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
Analogue addressable photo-thermal multi-criteria smoke detector with short circuit
isolator (B501AP, B524HTR and B524RTE bases)
Notes:
1) xx = (Range 0-99) ~ indicates the communication software protocol
2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
3) Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021:
2003
Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R
550b/03
550b/04
550b/05
550b/06
550e/01
550e/02
Bases:
B401 standard base
B401DG deep base
B401R standard base with schottky diode
B401SD standard base with schottky diode
B401RSD standard base with 470 ohm resistor and schottky diode
B401R1000 standard base with 1000 ohm resistor
B401DGR deep base with 470 ohm resistor
B401DGR1000 deep base with 1000 ohm resistor
B401DGSD deep base with schottky diode
ECO1000B standard base
ECO1000BSD standard base with schottky diode
ECO1000BR standard base, 470 ohm resistor
ECO1000BRSD standard base, 470 ohm resistor and schottky diode
ECO1000BR680 standard base, 680 ohm resistor
ECO1000BR680SD standard base, 680 ohm resistor and schottky diode
ECO1000BR1000 standard base, 1000 ohm resistor
ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode
B501 standard analogue detector base
B501DG deep analogue detector base
B5241EFT-1 analogue short circuit isolator base
FL/B401 standard base
FL/1000B standard base
B501AP intelligent detector base
B524HTR heater base
B524RTE latching relay base
BFA1 standard base
354
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 550c to EN 54-5: 2000 + A1: 2002
Certificate No: 550f to EN54-5: 2000 + A1: 2002 and EN 54-17: 2005
Heat Detectors
Certificated Products
5351E
4351E
ECO1005
FL/1005
5251EM
5251REM
52051RE-xx-yy
52051E-xx-yy
5FA51R
52051REI-xx-yy
52051EI-xx-yy
Class A1R conventional rate of rise heat detector
(B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 &
B401DGSD bases)
Note: Meets the requirements of EN54-5:2000 at class A1R.
Class BS conventional heat detector
(B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 &
B401DGSD bases)
Note: Meets the requirements of EN54-5:2000 at class BS.
Conventional A1R rate-of-rise heat detector
(ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680,
ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases)
Conventional Class A1R rate of rise heat detector
(FL/1000B base)
Analogue addressable Class A1S fixed temperature heat detector (B501, B501DG and
B5241EFT-1 bases)
Analogue addressable Class A1R high temperature rate of rise heat detector (B501,
B501DG and B5241EFT-1 bases)
Analogue addressable class A1R rate of rise heat detector
(B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)
Notes:
1) xx = (Range 0-99) ~ indicates the communication software protocol
2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Analogue addressable class A1S fixed temperature heat detector
(B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)
Notes:
1) xx = (Range 0-99) ~ indicates the communication software protocol
2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Conventional A1R rate of rise heat detector (BFA1 base)
Analogue addressable class A1R rate of rise heat detector with short circuit isolator
(B501AP, B524HTR and B524RTE bases)
Notes:
1) xx = (Range 0-99) ~ indicates the communication software protocol
2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
Analogue addressable class A1S fixed temperature heat detector with short circuit
isolator (B501AP, B524HTR and B524RTE bases)
Notes:
1) xx = (Range 0-99) ~ indicates the communication software protocol
2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White
LPCB Ref.
No.
550c/01
550c/02
550c/03
550c/03
550c/04
550c/05
550c/06
550c/07
550c/08
550f/01
550f/02
Bases:
B401 standard base
B401DG deep base
B401R standard base with schottky diode
B401SD standard base with schottky diode
B401RSD standard base with 470 ohm resistor and schottky diode
B401R1000 standard base with 1000 ohm resistor
B401DGR deep base with 470 ohm resistor
B401DGR1000 deep base with 1000 ohm resistor
B401DGSD deep base with schottky diode
ECO1000B standard base
ECO1000BSD standard base with schottky diode
ECO1000BR standard base, 470 ohm resistor
ECO1000BRSD standard base, 470 ohm resistor and schottky diode
ECO1000BR680 standard base, 680 ohm resistor
ECO1000BR680SD standard base, 680 ohm resistor and schottky diode
ECO1000BR1000 standard base, 1000 ohm resistor
ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode
FL/B401 standard base
FL/1000B standard base
B501 standard analogue detector base
B501AP intelligent detector base
B524IEFT-1 analogue short circuit isolator base
B524HTR heater base
B524RTE latching relay base
BFA1 Standard Base
20 Oct 2014
355
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Tanda Technologies (Singapore) Pte Ltd
217 Kallang Bahru, Multron Building, 339347, Singapore
Tel: +63956866
E-mail: [email protected]
Certificate No: 1148a-(cl-1) to EN 54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
DET-C632
Bases:
DB-6
Conventional rate of rise & fixed temperature heat detector (DB-6 standard base)
Note:Meets the requirements of EN 54-5 at Class A2R
LPCB Ref.
No.
1148a/01
Standard detector base
Certificate No: 1148b-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
DET-C631
Bases:
DB-6
Conventional optical smoke detector (DB-6 standard base)
Note:Meets the requirements of EN 54-7 in the normal sensitivity setting.
LPCB Ref.
No.
1148b/01
Standard detector base
Teledata S.r.l.
Via Giulietti 8, Milan 20132, Italy
Tel: +39 02-27201352 • Fax: +39 02-2593704
E-mail: [email protected] • Website: www.teledate-i.com
Certificate No: 928a-(cl-6) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005
Certificate No: 928d-(cl-6) to EN 54-5: 2000 + A1: 2002
Point Heat Detectors
Certificated Products
SF3500
SF3500E
Bases
BS100
BS100E
BS100/S
BS100E/S
Analogue addressable Class P heat detector with short circuit isolator
(BS100, BS100E, BS100/S and BS100E/S bases)
Note:
1.
Meets the requirements of EN 54-5 for Class A1R and Class B
Analogue addressable Class P heat detector lite
(BS100, BS100E, BS100/S and BS100E/S bases)
Note:
1.
Meets the requirements of EN 54-5 for Class A1R and Class B
LPCB Ref.
No.
928a/01
928d/01
Universal adaptor base
Vega adaptor base
Universal adaptor base with shorting clip
Vega adaptor base with shorting clip
Certificate No: 928b-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Certificate No: 928e-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 928f-(cl-6) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003
356
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Point Smoke Detectors
Certificated Products
SF1000
Analogue addressable photoelectric smoke detector with short circuit isolator
(BS100, BS100E, BS100/S and BS100E/S bases)
Note:
1.
Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Analogue addressable photoelectric smoke detector lite
(BS100, BS100E, BS100/S and BS100E/S bases)
Note:
1.
Meets the requirements of EN 54-7 at the following sensitivity settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
Analogue addressable Class P heat and photoelectric smoke multi-sensor detector lite
(BS100, BS100E, BS100/S and BS100E/S bases)
Notes:
1.
Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the
following settings:
Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
Multi Criteria Level 2 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 3 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
2.
Meets the requirements of EN 54-5 (Class A1R) at the following
settings:
Class A1R heat only response
3.
Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
Optical only level 3
Optical only level 4 - Low
SF1000E
SF2000E
Bases
BS100
BS100E
BS100/S
BS100E/S
LPCB Ref.
No.
928b/01
928e/01
928f/01
Universal adaptor base
Vega adaptor base
Universal adaptor base with shorting clip
Vega adaptor base with shorting clip
Certificate No: 928c-(cl-6) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
SF2000
20 Oct 2014
Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with
short circuit isolator
(BS100, BS100E, BS100/S and BS100E/S bases)
Notes:
1.
Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the
following settings:
Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
Multi Criteria Level 2 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 3 - Thermally enhanced smoke detection with Class
A1 heat response
Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke
detection with Class A1 heat response
2.
Meets the requirements of EN 54-5 (Class A1R) at the following
settings:
Class A1R heat only response
3.
Meets the requirements of EN 54-7 at the following settings:
Optical only level 1 - High
Optical only level 2
LPCB Ref.
No.
928c/01
357
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
Optical only level 3
Optical only level 4 - Low
Bases
BS100
BS100E
BS100/S
BS100E/S
Universal adaptor base
Vega adaptor base
Universal adaptor base with shorting clip
Vega adaptor base with shorting clip
Teletek Electronics JSC
14A Srebarna Street, Sofia 1407, Bulgaria
Tel: +359 2 9694 700 • Fax: +359 2 9625 213
E-mail: [email protected] • Website: www.teletek-electronics.com
Certificate No: 1139a to EN54-5: 2000 + A1: 2002
Heat Detectors
Certificated Products
T110
Analogue addressable class A1R heat detector (rate of rise and fixed temperature) (B124
base)
LPCB Ref.
No.
1139a/01
Base:
B124 Standard analogue addressable detector base
Certificate No: 1139b to EN54-7: 2000 + A1: 2002 + A2: 2006
Smoke Detectors
Certificated Products
S130
LPCB Ref.
No.
1139b/01
Analogue addressable optical smoke detector (B124 base)
Base:
B124 Standard analogue addressable detector base
Certificate No: 1139c to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Multi-Sensor/Multi-Criteria Detectors
Certificated Products
M140
Analogue addressable combined class A1R heat and optical smoke detector (B124 base)
LPCB Ref.
No.
1139c/01
Base:
B124 Standard analogue addressable detector base
Thorn Security Limited, trading as Tyco Safety Products
Dunhams Lane, Letchworth SG6 1BD, United Kingdom
Tel: +44 (0)1462 667700 • Fax: +44 (0)1462 667777
E-mail: [email protected] • Website: www.tycosafetyproducts-europe.com
Certificate No: 681c-(cl-1) to EN 54-5: 2000 + A1: 2002
Certificate No: 681p-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005
Heat Detectors
Certificated Products
801H
358
MX Digital addressable Class P heat detector (4B, 4B-I and 5B bases)
Note:
1. Meets EN54 Part 5 for classes A1R, A2S and CR.
LPCB Ref.
No.
681c/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
601H-R
601H-F
MD601Ex
MD611Ex
816H
611H-F
631H-F
840H
830H
850H (516.850.053)
850H (516.850.053.E)
Simplex (4098-6253)
Conventional Class A1R heat detector (4B, 4B-D and 5B bases)
Conventional Class A1S heat detector (4B, 4B-D and 5B bases)
Conventional intrinsically safe Class A1R rate of rise heat detector
(MUBEx base, 5BEx bases)
Conventional intrinsically safe Class A1S fixed temperature heat detector (MUBEx base,
5BEx base)
MX Digital addressable Class P heat detector (4B, 4B-I and 5B bases)
Note:
1. Meets EN54 Part 5 for classes A1R, A2S and CR.
Conventional Class A1S fixed temperature heat detector
(4B, 4B-D and 5B base)
Conventional Class CS fixed temperature heat detector
(4B, 4B-D and 5B base)
MX digital addressable Class P heat detector (4B, 4B-I, and 5B bases)
Note:
1. Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- Heat detector at Class CR
MX digital addressable Class P heat detector (4B, 4B-I, and 5B bases)
Note:
1. Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- Heat detector at Class CR
MX digital addressable Class P heat detector
(4B, 4B-C, and 5B bases)
Note:
1. Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- Heat detector at Class CR
MX Digital Addressable Class P Heat Detector with Short Circuit Isolator (4B, 4B-C and
5B bases)
Note:
Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- Heat detector at Class CR
MX Digital Addressable Class P Heat Detector with Short Circuit Isolator (4B, 4B-C and
5B bases)
Note:
Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- Heat detector at Class CR
LPCB Ref.
No.
681c/02
681c/03
681c/04
681c/05
681c/06
681c/07
681c/08
681c/09
681c/10
681p/01
681p/01
681p/01
Bases:
4B 4" universal mounting base
4B-C, 4” continuity base
4B-D 4" diode mounting base
4B-I, 4” isolator base
5B 5” Universal mounting base
5BEX Intrinsically safe detector base
MUBEx Intrinsically safe detector base
Certificate No: 681j-(cl-1) to EN 54-7: 2000 + AI: 2002 + A2: 2006 and CEA4021: 1999
Certificate No: 681b-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA4021: 2003
Certificate No: 681a-(cl-1) to EN 54-5: 2000 + A1: 2002 and Test Schedule 68297/29.0 Test schedule for Carbon Monoxide Fire
Detectors
Certificate No: 681e-(cl-1) to EN 54-5: 2000 + A1: 2002 and LPS1265 Iss.1.0
Certificate No: 681w-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA4021: 2003
Multi-criteria Detectors
Certificated Products
801CH
20 Oct 2014
MX Digital addressable Carbon Monoxide and Class P heat detector
(4B and 5B bases)
Notes:
Approved with the following mode configurations:-
LPCB Ref.
No.
681a/01
359
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
1. Carbon monoxide detector at High and Normal sensitivity
2. Rate of rise heat detector at Class A1R
3. Fixed temperature heat detector at Class A2S
4. Heat enhanced carbon monoxide fire detector at High and Normal sensitivity
5. Heat enhanced carbon monoxide fire detector at High and Normal sensitivity and rate
of rise heat detector at Class A1R
801PH
Conditions of approval:
1. The 801CH should only be installed in accordance with the manufacturers
recommendations.
2. The 801CH should not be set only as a carbon monoxide fire detector where there is
a specific risk of rapid burning / flaming fires.
3. Refer to technical publication 17A-02-DET for limitations on the use of carbon
monoxide fire detection.
MX digital addressable photoelectric smoke and Class P heat detector
(4B, 4B-I and 5B Bases)
681b/01
Note:
Approved with the following mode configurations:1. Optical smoke detector at High and Normal sensitivity
2. Rate of rise heat detector at Class A1R
3. Fixed temperature heat detector at Class A2S
4. Heat enhanced optical smoke detector at High and Normal sensitivity
5. Optical smoke detector using FastLogic at High and Normal sensitivity
6. Heat enhanced optical smoke detector using FastLogic at High and Normal sensitivity
840PC
830PC
840PH
830PH
601CH
601PH
MR601Tex
360
MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide
detector (4B, 4B-I, and 5B bases)
Notes:
1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector
- RESIL Resilient optical smoke and A2S heat multi-criteria detector
- Heat detector at Class A1R
- HPO Heat enhanced optical smoke detector at Normal sensitivity
2. The Carbon Monoxide toxic gas/CCO modes are not approved
MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide
detector (4B, 4B-I, and 5B bases)
Notes:
1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector
- RESIL Resilient optical smoke and A2S heat multi-criteria detector
- Heat detector at Class A1R
- HPO Heat enhanced optical smoke detector at Normal sensitivity
2. The Carbon Monoxide toxic gas/CCO modes are not approved
MX digital addressable photoelectric smoke and Class P heat detector (4B, 4B-I, and
5B bases)
Note:
Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity
- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using
FastLogic.
MX digital addressable photoelectric smoke and Class P heat detector (4B, 4B-I, and
5B bases)
Note:
Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity
- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using
FastLogic.
Conventional Class A1R thermally enhanced Carbon Monoxide detector
(4B, 4B-D and 5B Bases)
Conventional high performance photoelectric smoke detector (4B, 4B-D and 5B bases)
Conventional intrinsically safe high performance photoelectric smoke detector with heat
enhancement (MUBEx base, 5BEx bases)
681b/02
681b/03
681b/04
681b/05
681e/01
681j/01
681j/02
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
816PH
850PC (516.850.054)
850PC (516.850.054.E)
Simplex (4098-6254)
851PCN
850PH (516.850.051)
850PH (516.850.051.E)
Simplex (4098.6251)
20 Oct 2014
MX Digital addressable photoelectric detector with heat enhancement (4B and 5B bases)
Note:
1. Meets EN54 Part 7 at Normal sensitivity
MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide
detector with short circuit isolator
(4B, 4B-C and 5B bases)
Notes:
1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector
- RESIL Resilient optical smoke and A2S heat multi-criteria detector
- Heat detector at Class A1R
- HPO Heat enhanced optical smoke detector at Normal sensitivity
2. The Carbon Monoxide toxic gas/CCO modes are not approved
MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide
detector with short circuit isolator (4B, 4B-C and 5B bases)
Notes:
1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector
- RESIL Resilient optical smoke and A2S heat multi-criteria detector
- Heat detector at Class A1R
- HPO Heat enhanced optical smoke detector at normal sensitivity
2. The Carbon Monoxide toxic gas/CCO modes are not approved
MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide
detector with short circuit isolator (4B, 4B-C and 5B bases)
Notes:
1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector
- RESIL Resilient optical smoke and A2S heat multi-criteria detector
- Heat detector at Class A1R
- HPO Heat enhanced optical smoke detector at normal sensitivity
2. The Carbon Monoxide toxic gas/CCO modes are not approved
MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide
detector with short circuit isolator [Ex(N) version] (4B-EN base)
Notes:
1. Approved with the following mode configurations:- UNIV Universal optical smoke and A2S heat multi-criteria detector
- RESIL Resilient optical smoke and A2S heat multi-criteria detector
- Heat detector at Class A1R
- HPO Heat enhanced optical smoke detector at Normal sensitivity
2. The Carbon Monoxide toxic gas/CCO modes are not approved
MX digital addressable photoelectric smoke and Class P heat detector with short circuit
isolator (4B, 4B-C, and 5B bases)
Note:
Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity
- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using
FastLogic.
MX digital addressable photoelectric smoke and Class P heat detector with short circuit
isolator (4B, 4B-C, and 5B bases)
Note:
1. Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity
- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using
FastLogic.
MX digital addressable photoelectric smoke and Class P heat detector with short circuit
isolator (4B, 4B-C, and 5B bases)
Note:
1. Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity
- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using
LPCB Ref.
No.
681j/03
681w/01
681w/01
681w/01
681w/02
681w/03
681w/03
681w/03
361
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
851PH
851PHN
LPCB Ref.
No.
FastLogic.
MX digital addressable photoelectric smoke and Class P heat detector with short circuit
isolator [Marine version] (4B, 4B-C, and 5B bases)
Note:
1. Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity
- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using
FastLogic.
MX digital addressable photoelectric smoke and Class P heat detector with short circuit
isolator [Ex(N) version] (4B-EN base)
Note:
1. Approved with the following mode configurations:- Heat detector at Class A1R
- Heat detector at Class A2S
- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity
- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using
FastLogic.
681w/04
681w/05
Bases:
4B 4” universal mounting base
4B-C 4” continuity base
4B-D Diode mounting base
4B-D 4" Diode mounting base
4B-EN 4” Ex{N} compliant mounting base
4B-I, 4” isolator base
5B 5” Universal mounting base
5BEx Intrinsically safe mounting base
MUB Universal mounting base
MUBEx intrinsically safe detector base
DHM-5B - Deck head mounting adaptor for 5" base
Certificate No: 763a to EN 54-10: 2002
Certificate No: 681r-(cl-1) to EN 54-10: 2002 + A1: 2005
Certificate No: 018e-(cl-1) to EN 54-10: 2001+ A1:2005
Flame Detectors
Certificated Products
S231i+
S231f+
S241i+
S241f+
S251i+
S251f+
S261f+
S271f+
S271i+
601F
601FEx
801F
801FEx
S231i+
S231f+
S241i+
S241f+
S251i+
S251f+
S261f+
S271f+
S271i+
S231i+
S231f+
S241i+
362
Class 1, conventional 2-wire intrinsically safe IR flame detector
Class 1, conventional 2-wire flame proof IR flame detector
Class 1, 4-20mA intrinsically safe IR flame detector
Class 1, 4-20mA flame proof IR flame detector
Class 1, analogue addressable intrinsically safe IR flame detector
Class 1, analogue addressable flame proof IR flame detector
Class 1, relay flame proof IR flame detector
Class 1, analogue addressable intrinsically safe triple IR flame detector with MX interface
Class 1, analogue addressable flame proof triple IR flame detector with MX interface
Conventional Class 2 flame detector (4B, 4B-D and 5B bases)
Conventional Class 2 intrinsically safe flame detector (MUBEx and 5BEx bases)
MX addressable Class 2 flame detector (4B and 5B bases)
MX addressable Class 2 intrinsically safe flame detector (MUBEx and 5BEx bases)
Class 1, Conventional 2-Wire Intrinsically Safe IR Flame Detector
Class 1, Conventional 2-Wire Flame Proof IR Flame Detector
Class 1, 4-20mA Intrinsically Safe IR Flame Detector
Class 1, 4-20mA Flame Proof IR Flame Detector
Class 1, Analogue Addressable Intrinsically Safe IR Flame Detector
Class 1, Analogue Addressable Flame Proof IR Flame Detector
Class 1, Relay Flame Proof IR Flame Detector
Class 1, Analogue Addressable Intrinsically Safe Triple IR Flame Detector with MX
Interface
Class 1, Analogue Addressable Flame Proof Triple IR Flame Detector with MX Interface
Conventional class 1 2-wire intrinsically safe IR flame detector
Conventional class 1 2-wire flame proof IR flame detector
4-20mA current class 1 intrinsically safe IR flame detector
LPCB Ref.
No.
018e/01
018e/02
018e/03
018e/04
018e/05
018e/06
018e/07
018e/08
018e/09
681r/01
681r/02
681r/03
681r/04
681r/05
681r/06
681r/07
681r/08
681r/09
681r/10
681r/11
681r/12
681r/13
763a/01
763a/02
763a/03
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
S241f+
S251i+
S251f+
S261f+
S271i+
S271f+
4-20mA current class 1 flame proof IR flame detector
Analogue addressable class 1 intrinsically safe IR flame detector
Analogue addressable class 1 flame proof IR flame detector
Relay class 1 flame proof IR flame detector
Analogue class 1 triple IR flame detector with MX interface
Analogue class 1 flame proof triple IR flame detector with MX interface
LPCB Ref.
No.
763a/04
763a/05
763a/06
763a/07
763a/08
763a/09
Bases:
4B 4” standard mounting base
4B-D 4” diode mounting base
5B standard mounting base
MUBEx Intrinsically safe mounting base
5BEx Intrinsically safe mounting base
MUB standard mounting base
5B standard mounting base
5BI addressable isolator base
Certificate No: 681d-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificate No: 681z-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005
Smoke Detectors
Certificated Products
801I
601I
601P
816P
840P
830P
850P (516.850.052)
850P (516.850.052.E)
Simplex (4098-6252)
MX Digital addressable ionisation smoke detector (4B, 4B-I and 5B bases)
Note:
1. Meets EN54 Part 7 at High and Normal Sensitivity
Conventional ionisation smoke detector (4B, 4B-D and 5B bases)
Conventional optical smoke detector (4B, 4B-D and 5B bases)
MX Digital addressable photoelectric smoke detector
(4B, 4B-I and 5B bases)
Note:
1. Meets EN54 Part 7 at High and Normal Sensitivity
MX digital addressable photoelectric smoke detector
(4B, 4B-I, and 5B bases)
Note:
1. Approved with the following mode configurations:- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
MX digital addressable photoelectric smoke detector (4B,
4B-I, and 5B bases)
Note:
1. Approved with the following mode configurations:- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
MX digital addressable photoelectric smoke detector with short circuit isolator (4B, 4B-C
and 5B bases)
Note:
1. Approved with the following mode configurations:- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
MX digital addressable photoelectric smoke detector with short circuit isolator (4B, 4B-C
and 5B bases)
Note:
Approved with the following mode configurations:- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
MX digital addressable photoelectric smoke detector with short circuit isolator (4B, 4B-C
and 5B bases)
Note:
Approved with the following mode configurations:- OPT Optical smoke detector at High, Normal and Low sensitivity
- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic
LPCB Ref.
No.
681d/01
681d/02
681d/03
681d/05
681d/06
681d/07
681z/01
681z/01
681z/01
Bases:
4B 4" universal mounting base
4B-C, 4” continuity base
4B-D Diode mounting base
4B-I, 4” isolator base
5B 5” Universal mounting base
20 Oct 2014
363
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificate No: 681aa-(cl-1) to EN 54-17: 2005
Isolating base
Certificated Products
4B-I
LPCB Ref.
No.
681aa/01
Short circuit isolator base
UniPOS Ltd
47 San Stefano Street, Pleven, Bulgaria
Tel: +359 64 891124
E-mail: [email protected] • Website: www.unipos-bg.com
Certificate No: 1107a to EN 54-5: 2000 A1: 2002
Certificated Products
FD7120
FD8020
LPCB Ref.
No.
1107a/01
Analogue addressable rate of rise heat detector (7100 base)
Note:
Meets the requirements of EN 54-5 at Class A2R
Conventional rate-of-rise heat detector (8000 base)
Note:
Meets the requirements of EN 54-5 at Class A2R
1107a/02
Bases
7100 standard analogue detector base
8000 standard conventional detector base
Certificate No: 1107b to EN 54-7: 2001 + A1: 2002 + A2: 2006
Certificated Products
FD7130
FD8030
LPCB Ref.
No.
1107b/01
Analogue addressable optical smoke detector (7100 base)
Note:
Meets the requirements of EN 54-7 in the normal sensitivity setting.
Conventional optical smoke detector (8000 base)
Note:
Meets the requirements of EN 54-7 in the normal sensitivity setting.
1107b/02
Bases
7100 standard analogue detector base
8000 standard conventional detector base
Certificate No: 1107c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2001 + A1: 2002 + A2: 2006 & CEA 4021: July 2003
Certificated Products
FD7160
FD8060
Analogue addressable combined heat & optical smoke detector (7100 base)
Note:
Meets the requirements of EN 54-5: 2000 (Class A2R) & EN54-7: 2000 at default normal
sensitivity setting.
Conventional combined heat & optical smoke detector (8000 base)
Note:
Meets the requirements of EN 54-5: 2000 (Class A2R) & EN54-7: 2000 at default normal
sensitivity setting.
LPCB Ref.
No.
1107c/01
1107c/02
Bases
7100 standard analogue detector base
8000 standard conventional detector base
364
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
UTC Fire & Security BV
Kelvinstraat 7, NL-6003DH, Weert, The Netherlands
Tel: + 31 495 58 30 00 • Fax: + 31 495 55 00 42
E-mail: Daragh.O'[email protected] • Website: www.utcfireandsecurity.com
Certificate No: 092p-(cl-1) to EN 54-5: 2000 + A1: 2002
Certificated Products
EA20E-3
Analogue addressable Class P heat detector
(ZP7-SB1 base) (Labelled EST)
Note:
1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only.
Analogue addressable Class P heat detector
(ZP7-SB1 base) (Labelled Photain Controls)
Note:
1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only.
Analogue addressable Class P heat detector
(ZP7-SB1 base) (Labelled Plana Fabrega)
Note:
1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only.
Analogue addressable Class P heat detector
(ZP7-SB1 base) (Labelled Ziton)
Note:
1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only.
Conventional Class A1 heat detector
(E6-BS1 base) (Labelled EST)
Conventional Class A1 heat detector
(Z6-BS1 & Z6-BS5 bases) (Labelled Ziton)
Conventional fixed temperature heat detector, Polar white, (Class A1)
& Z6-BS5-P bases) (Labelled Ziton)
Conventional Class A1R heat detector
(E6-BS1 base) (Labelled EST)
Conventional Class A1R heat detector
(FSBP2000 base) (Labelled Photain Controls)
Conventional Class A1R heat detector
(BD-21 & BD-22 bases) (Labelled Plana Fabrega)
Conventional Class A1R heat detector
(Z6-BS1 & Z6-BS5 bases) (Labelled Ziton)
Conventional rate of rise heat detector, Polar white, (Class A1R)
& Z6-BS5-P bases) (Labelled Ziton)
Conventional Class B heat detector
(E6-BS1 base) (Labelled EST)
Conventional Class B heat detector
(FSBP2000 base) (Labelled Photain Controls)
Conventional Class B heat detector
(Z6-BS1 & Z6-BS5 bases) (Labelled Ziton)
Conventional high temperature heat detector, Polar white, (Class B)
& Z6-BS5-P bases) (Labelled Ziton)
PRRPHDI2004
T-17003
ZP720-3
E620-581-3
Z620-581-3
Z620-581-3P
E620-582-3
PRRP2004
TV-7003
Z620-582-3
Z620-582-3P
E620-771-3
PHDP2004HT
Z620-771-3
Z620-771-3P
Bases
ZP7-SB1
Z6-BS1
E6-BS1
BD-21
FSBP2000
Z6-BS5
BD-22
Z6-BS1-P
Z6-BS5-P
LPCB Ref.
No.
092p/01
092p/01
092p/01
092p/01
092p/02
092p/02
092p/02
092p/03
092p/03
092p/03
092p/03
092p/03
092p/04
092p/04
092p/04
092p/04
Standard base
Conventional surface base
Conventional surface base
Conventional surface base
Conventional surface base
Conventional diode base
Conventional diode base
Polar white conventional surface base
Polar white conventional diode base
Certificate No: 092n-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Certificated Products
EA10E-2
20 Oct 2014
Analogue addressable ionisation smoke detector
(ZP7-SB1 base) (Labelled EST)
LPCB Ref.
No.
092n/01
365
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
Note:
1. Approved for use at Standard sensitivity setting only.
Analogue addressable ionisation smoke detector
(ZP7-SB1 base) (Labelled Plana Fabrega)
Note:
1. Approved for use at Standard sensitivity setting only.
Analogue addressable ionisation smoke detector
(ZP7-SB1 base) (Labelled Photain Controls)
Note:
1. Approved for use at Standard sensitivity setting only.
Analogue addressable ionisation smoke detector
(ZP7-SB1 base) (Labelled Ziton)
Note:
1. Approved for use at Standard sensitivity setting only.
Analogue addressable photoelectric smoke detector
(ZP7-SB1 base) (Labelled EST)
Note:
1. Approved for use at Standard sensitivity setting only.
Analogue addressable photoelectric smoke detector
(ZP7-SB1 base) (Labelled Plana Fabrega)
Note:
1. Approved for use at Standard sensitivity setting only.
Analogue addressable photoelectric smoke detector
(ZP7-SB1 base) (Labelled Photain Controls)
Note:
1. Approved for use at Standard sensitivity setting only.
Analogue addressable photoelectric smoke detector
(ZP7-SB1 base) (Labelled Ziton)
Note:
1. Approved for use at Standard sensitivity setting only.
Analogue addressable optical smoke sensor,
(ZP7-SB1-P base) (Labelled Ziton with Chubb logo)
Note:
Approved for use at Standard sensitivity setting only.
I-17001
ISDI2000
ZP710-2
EA30E-2
O-17002
PPDI2000
ZP730-2
ZP730-2S30
E610-3
Conventional ionisation smoke detector
(E6-BS1 base) (Labelled EST)
Conventional ionisation smoke detector
(Z6-BS1 & Z6-BS5 bases) (Labelled Ziton)
Conventional photoelectric smoke detector
(E6-BS1 base) (Labelled EST)
Conventional photoelectric smoke detector
(BD-21 & BD-22 bases) (Labelled Plana Fabrega)
Conventional photoelectric smoke detector
(FSBP2000 base) (Labelled Photain Controls)
Conventional photoelectric smoke detector
(Z6-BS1 & Z6-BS5 bases) (Labelled Ziton)
Conventional optical smoke detector, Polar white
& Z6-BS5-P bases) (Labelled Ziton)
Conventional optical smoke detector, Polar white, Chubb
& Z6-BS5 basesZiton with Chubb logo)
Z610-3
E630-3
O-7002
PPDP2004
Z630-3
Z630-3P
Z630-3S30
Bases
ZP7-SB1
Z6-BS1
E6-BS1
BD-21
FSBP2000
Z6-BS5
BD-22
Z6-BS1-P
Z6-BS5-P
LPCB Ref.
No.
092n/01
092n/01
092n/01
092n/02
092n/02
092n/02
092n/02
092n/02
092n/03
092n/03
092n/04
092n/04
092n/04
092n/04
092n/04
092n/04
Standard base
Conventional surface base
Conventional surface base
Conventional surface base
Conventional surface base
Conventional diode base
Conventional diode base
Polar white conventional surface base
Polar white conventional diode base
Certificate No: 092k-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Certificated Products
EA32E-2
366
Analogue addressable combined photoelectric smoke and heat detector.
(Labelled EST) (ASBE-2 base)
Note:
1. Certificated at sensitivity profiles 1-4 for EN 54:7and sensitivity profiles
LPCB Ref.
No.
092k/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
5 (A1) and 6(A2) for EN 54:5.
Analogue addressable combined photoelectric smoke and heat detector.
(Labelled EEC) (ZP7-SB1 base)
Note:
1. Certificated at sensitivity profiles 1-4 for EN 54:7 and sensitivity profiles
5 (A1) and 6(A2) for EN 54:5.
Analogue addressable combined photoelectric smoke and heat detector.
(Labelled Plana Fabrega) (ZP7-SB1 base)
Note:
1. Certificated at sensitivity profiles 1-4 for EN 54:7 and sensitivity profiles
5 (A1) and 6(A2) for EN 54:5.
Analogue addressable combined photoelectric smoke and heat detector.
(Labelled Photain Controls) (ZP7-SB1 base)
Note:
1. Certificated at sensitivity profiles 1-4 for EN 54:7and sensitivity profiles
5 (A1) and 6(A2) for EN 54:5.
Analogue addressable combined photoelectric smoke and heat detector.
(Labelled Ziton) (ZP7-SB1 base)
Note:
1. Certificated at sensitivity profiles 1-4 for EN 54:7and sensitivity profiles
EAS707
OT-17004
PPDPHDI2000
ZP732-2
5 (A1) and 6(A2) for EN 54:5.
Analogue addressable combination smoke and heat detector,
(Labelled Ziton with Chubb logo) (ZP7-SB1-P base)
Note :
Certificated at sensitivity profiles 1-4 for EN 54:7 and sensitivity profiles
ZP732-2S30
092k/01
092k/01
092k/01
092k/01
092k/01
5 (A1) and 6 (A2) for EN 54:5.
Bases
ZP7-SB1 Standard base
ASBE-2 Standard base
UTC Fire & Security Inc. Trading as Edwards Systems Technology
129 North Main Street, Pittsfield, Maine 04967, USA
Tel: 941 739-42228
Website: www.fs.utc.com
Certificate No: 262s-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
SIGA-IPHSI
SIGA-PHSI
Bases:
SIGI-IBS
SIGA-SB
SIGA-SB4
SIGA-RB
20 Oct 2014
Intelligent analogue addressable thermally enhanced photoelectric and ionisation smoke
detector
(SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,
SIGA-IB, SIGA-IB4 & SIGA-AB4G bases)
Notes:
1. Meets the requirements of EN 54-7:2000 at sensitivity
settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft.
2. The SIGA-LED indicator is approved for use with
the SIGA-SB and SIGA-SB4 bases
Intelligent analogue addressable thermally enhanced photoelectric smoke detector
(SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,
SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)
Notes:
1. Meets the requirements of EN 54-7:2000 at sensitivity
settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft.
2. The SIGA-LED indicator is approved for use with
the SIGA-SB and SIGA-SB4 bases
LPCB Ref.
No.
262s/01
262s/02
Isolator base
Standard base
Standard base with trim skirt
Relay base
367
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
SIGA-RB4
SIGA-IB
SIGA-IB4
SIGA-AB4G
Relay base with trim skirt
Isolator Base
Isolator base with 4 inch mounting adaptors
Sounder base
Accessories:
SIGA-LED
Indicator
Certificate No: 262t-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
SIGA-PSI
Intelligent analogue addressable photoelectric smoke detector
(SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,
SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)
Notes:
1. Meets the requirements of EN 54-7:2000 at sensitivity
settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft.
2. The SIGA-LED indicator is approved for use with
the SIGA-SB and SIGA-SB4 bases
Bases:
SIGI-IBS
SIGA-SB
SIGA-SB4
SIGA-RB
SIGA-RB4
SIGA-IB
SIGA-IB4
SIGA-AB4G
Isolator base
Standard base
Standard base with trim skirt
Relay base
Relay base with trim skirt
Isolator Base
Isolator base with 4 inch mounting adaptors
Sounder base
Accessories:
SIGA-LED
Indicator
LPCB Ref.
No.
262t/02
Certificate No: 262u-(cl-1) to EN 54-5: 2000 + A1: 2002.
Point Heat Detectors
Certificated Products
SIGA-HRSI
Intelligent analogue addressable Class A1 & A2R rate of rise heat detector
(SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB,
SIGA-IB4 and SIGA-AB4G bases)
Note:
1. The SIGA-LED indicator is also approved for use with
the SIGA-SB and SIGA-SB4 bases
Bases:
SIGI-IBS
SIGA-SB
SIGA-SB4
SIGA-RB
SIGA-RB4
SIGA-IB
SIGA-IB4
SIGA-AB4G
Isolator base
Standard base
Standard base with trim skirt
Relay base
Relay base with trim skirt
Isolator Base
Isolator base with 4 inch mounting adaptors
Sounder base
Accessories:
SIGA-LED
Indicator
368
LPCB Ref.
No.
262u/02
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
VRC Terofire Products
Lion House, Lion Street, Congleton, Cheshire CW12 4BH, United Kingdom
Tel: +44 (0)1260 297578 • Fax: +44 (0)1260 290078
E-mail: [email protected]
Certificate No: 512d to EN 54-5: 2000 + A1: 2002
Point Heat Detectors
Certificated Products
10-0003
10-0003
Conventional 2 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector
with LED output (P/N854001 base)
Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector
with LED output (P/N854001 base)
LPCB Ref.
No.
512d/03
512d/04
Bases:
P/N854001 4-Wire detector base
Certificate No: 512a to EN 54-7: 2000 + A1: 2002 + A2: 2006
Point Smoke Detectors
Certificated Products
10-0001
Conventional 2 wire photoelectric smoke detector with remote LED output (P/N854001
base)
LPCB Ref.
No.
512a/02
Base
P/N854001 4-Wire detector base
Certificate No: 512b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003
Multi-Criteria Detectors
Certificated Products
10-0002
Conventional 2 wire photoelectric smoke and heat detector with remote LED output
(P/N854001 base)
LPCB Ref.
No.
512b/02
Base
P/N854001 4-Wire detector base
Wagner Group GmbH
Schleswigstraße 5, D-30853 Langenhagen, Germany
Tel: +49 511 97383 0 • Fax: +49 511 73338 6
E-mail: [email protected] • Website: www.wagner.de
Certificate No: 524c to EN 54-20: 2006
Aspirating Smoke Detectors
Certificated Products
LPCB Ref.
No.
524c/01
TITANUS PRO-SENS
Notes:
1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be
supplied with power from a power supply conforming to the requirements of EN
54-4.

System design, installation and commissioning shall be performed in
accordance with the manufacturer’s installation guide, associated manuals and
20 Oct 2014
369
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.

design software TF-SC-1.
The detector shall be installed with sampling pipe conforming to EN 61386-1,
to at least Class 1131.
2.
Approved detector configurations (Class A, Class B and Class C):

TP-1/a (standard version, no bargraph display, 1 alarm, not available for
networking)

TP-1-F/a (deep freeze version, no bargraph display, 1 alarm, not available for
networking )

TP-1-SL (silent version, no bargraph display, 1 alarm, not available for
networking)
3.
The approved detector must incorporate one or two of the following detector
modules:

DM-TP-01-L (standard version, sensitivity of 0.015%/m)

DM-TP-01-L-F (deep freeze version, sensitivity of 0.015%/m)

DM-TP-10-L (standard version, sensitivity of 0.10%/m)

DM-TP-10-L-F (deep freeze version, sensitivity of 0.10%/m)

DM-TP-50-L (standard version, sensitivity of 0.50%/m)

DM-TP-50-L-F (deep freeze version, sensitivity of 0.50%/m)
TITANUS PRO-SENS/net
524c/02
Notes:
1. Approval of the detector is conditional upon the following requirements:
 For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be
supplied with power from a power supply conforming to the requirements of EN
54-4.
 System design, installation and commissioning shall be performed in
accordance with the manufacturer’s installation guide, associated manuals and
design software TF-SC-1.
 The detector shall be installed with sampling pipe conforming to EN 61386-1,
to at least Class 1131.
2.
Approved detector configurations (Class A, Class B and Class C):
 TP-3 (standard version, no bargraph display, 1 alarm, prepared for networking)
 TP-3-F (deep freeze version, no bargraph display, 1 alarm, prepared for
networking)
 TP-3-SL (silent version, no bargraph display, 1 alarm, prepared for networking)
 TP-4 (standard version, no bargraph display, 2 alarms, prepared for
networking)
 TP-4-F (deep freeze version, no bargraph display, 2 alarms, prepared for
networking)
 TP-4-SL (silent version, no bargraph display, 2 alarms, prepared for
networking)
 TP-5 (standard version, no bargraph display, 3 alarms, prepared for
networking)
 TP-5-F (deep freeze version, no bargraph display, 3 alarms, prepared for
networking)

TP-5-SL (silent version, no bargraph display, 3 alarms, prepared for
networking)
3
The approved detector must incorporate one or two of the following detector
modules:
 DM-TT-01-L (standard version, sensitivity of 0.015%/m)
 DM-TT-01-L-F (deep freeze version, sensitivity of 0.015%/m)
 DM-TT-10-L (standard version, sensitivity of 0.10%/m)
 DM-TT-10-L-F (deep freeze version, sensitivity of 0.10%/m)
 DM-TT-50-L (standard version, sensitivity of 0.50%/m)

DM-TT-50-L-F (deep freeze version, sensitivity of 0.50%/m)
TITANUS TOP-SENS
524c/03
Notes:
1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be
supplied with power from a power supply conforming to the requirements of EN
54-4.

System design, installation and commissioning shall be performed in
accordance with the manufacturer’s installation guide, associated manuals and
design software TF-SC-1.

The detector shall be installed with sampling pipe conforming to EN 61386-1,
to at least Class 1131.
370
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
2.
Approved detector configurations (Class A, Class B and Class C):

TT-1/a (standard version, bargraph display, 3 alarms, prepared for networking)

TT-1-F/a (deep freeze version, bargraph display, 3 alarms, prepared for
networking)

TT-1-SL (silent version, bargraph display, 3 alarms, prepared for networking)
3.
The approved detector must incorporate one or two of the following detector
modules:

DM-TT-01-L (standard version, sensitivity of 0.015%/m)

DM-TT-01-L-F (deep freeze version, sensitivity of 0.015%/m)

DM-TT-10-L (standard version, sensitivity of 0.10%/m)

DM-TT-10-L-F (deep freeze version, sensitivity of 0.10%/m)

DM-TT-50-L (standard version, sensitivity of 0.50%/m)

DM-TT-50-L-F (deep freeze version, sensitivity of 0.50%/m)
TITANUS MICRO-SENS
524c/04
Notes:
1. Approval of the detector is conditional upon the following requirements:
 For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be
supplied with power from a power supply conforming to the requirements of EN
54-4.
 System design, installation and commissioning shall be performed in
accordance with the manufacturer’s installation guide, associated manuals and
design software TF-SC-1.
 The detector shall be installed with sampling pipe conforming to EN 61386-1,
to at least Class 1131.
20 Oct 2014
2.
Approved detector configurations, sensitivity of 0.10%/m (Class A, Class B and
Class C):
 DM-TM-10 (standard version)
 DM-TM-R-10 (version with ROOM IDENT)
 DM-TM-B-10 (version with bargraph display)
 DM-TM-RB-10 (version with ROOM IDENT, bargraph display)
 DM-TM-Z-10 (version with redundancy fan)
 DM-TM-ZB-10 (version with redundancy fan, bargraph display)
 DM-TM-10-F (deep freeze version)
 DM-TM-B-10-F (version with bargraph display, deep freeze)
 DM-TMV-10 (version with 2 stages of alarm)
 DM-TMV-R-10 (version with 2 stages of alarm, ROOM IDENT)
 DM-TMV-B-10 (version with 2 stages of alarm, bargraph display)
 DM-TMV-RB-10 (version with 2 stages of alarm, ROOM IDENT, bargraph
display)
 DM-TMV-10-F (version with 2 stages of alarm, deep freeze)
 DM-TMV-B-10-F (version with 2 stages of alarm, bargraph display, deep
freeze)
 DM-MB-TM-10 (version without fan to be used as detector box)

DM-MB-TM-B-10 (version without fan to be used as detector box, bargraph
display)
3.
Approved detector configurations, sensitivity of 0.50%/m (Class A, Class B and
Class C):
 DM-TM-50 (standard version)
 DM-TM-R-50 (version with ROOM IDENT)
 DM-TM-B-50 (version with bargraph display)
 DM-TM-RB-50 (version with ROOM IDENT, bargraph display)
 DM-TM-Z-50 (version with redundancy fan)
 DM-TM-ZB-50 (version with redundancy fan, bargraph display)
 DM-TM-50-F (deep freeze version)
 DM-TM-B-50-F (version with bargraph display, deep freeze)
 DM-TMV-50 (version with 2 stages of alarm)
 DM-TMV-R-50 (version with 2 stages of alarm, ROOM IDENT)
 DM-TMV-B-50 (version with 2 stages of alarm, bargraph display)
 DM-TMV-RB-50 (version with 2 stages of alarm, ROOM IDENT, bargraph
display)
 DM-TMV-50-F (version with 2 stages of alarm, deep freeze)
 DM-TMV-B-50-F (version with 2 stages of alarm, bargraph display, deep
freeze)
 DM-MB-TM-50 (version without fan to be used as detector box)
 DM-MB-TM-B-50 (version without fan to be used as detector box, bargraph
display)
371
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
TITANUS RACK-SENS
524c/05
Notes:
1. Approval of the detector is conditional upon the following requirements:
 For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be
supplied with power from a power supply conforming to the requirements of EN
54-4.
 System design, installation and commissioning shall be performed in
accordance with the manufacturer’s installation guide, associated manuals and
design software TF-SC-1.
 The detector shall be installed with sampling pipe conforming to EN 61386-1,
to at least Class 1131.
2.
Approved detector configurations (Class A, Class B and Class C):
 TR1-10 (placed in a ‘1U’ housing, sensitivity of 0.10%/m)
 TR1-50 (placed in a ‘1U’ housing, sensitivity of 0.50%/m)
 TR2-10 (placed in a ‘2U’ housing, sensitivity of 0.10%/m)

TR2-50 (placed in a ‘2U’ housing, sensitivity of 0.50%/m)
Xtralis Pty Limited
4 North Drive, Virginia Park, 236-262 East Boundary Road, East Bentleigh, Victoria 3165, Australia
Tel: +61 3 9936 7001, +44 (0)1442 242330 • Fax: +61 3 9936 7201
E-mail: [email protected] • Website: www.xtralis.com
European Operations at:
Xtralis (UK) Limited, Vision House, Focus 31, Mark Road, Hemel Hempstead, Hertfordshire HP2 7BW, United
Kingdom
Tel: +44 (0)1442 242330 • Fax: +44 (0)1442 249327
Certificate No: 305e to EN 54-20: 2006
Certificate No: 305d to EN 54-20: 2006
Certificate No: 305g to EN 54-20: 2006
Aspirating Smoke Detectors
Certificated Products
VESDA VLF-250-xx (VLF250-01NF*) high sensitivity
aspirating smoke detector
372
Incorporating the following ancillary equipment:
VIC-010 VESDAnet network card
VIC-020 Multifunction control card
VIC-030 Multifunction control card
VRT-V00 Remote VLF display (with 7 relays)
VRT-W00 Remote VLF display (no relays)
VRT-500 Remote relay unit (with 7 relays)
Notes:
1.
For compliance with clause 5.10 of EN 54-20 the detector shall be supplied
with power from a power supply conforming to the requirements of EN 54-4.
2.
The device is approved for sensitivity Classes A, B and C. The Class of any
pipe/hole configuration and detector sensitivity must be determined using
ASPIRE2.
3.
System design, installation and commissioning shall be performed in
accordance with the VESDA VLF product guide (07208).
4.
Remote display, programmer and relay modules are also approved in a 19
sub rack.
5.
The detector is also approved when used with in-line filter models,
E700-FILASSY and VSP-850 in accordance with the appropriate
VESDA application guide (10856 or 17785).
6.
xx denotes alternative language version where xx (range 00 to 99)
designates the language of the product labels.
7.
Alternative model number with suffix* as indicated, intended for French
market.
8.
When installing pipework systems containing in-line components, guidance
from the 18336 "Xtralis Open-flow In-Line Components" document shall be
LPCB Ref.
No.
305d/01
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
VESDA VLF-500-xx (VLF500-01NF*) high sensitivity
aspirating smoke detector
VESDA VLC High
sensitivity aspirating smoke
detector
VESDA VLP High
sensitivity aspirating smoke
detector
20 Oct 2014
LPCB Ref.
No.
sought and the recommendations followed.
Incorporating the following ancillary equipment:
VIC-010 VESDAnet network card
VIC-020 Multifunction control card
VIC-030 Multifunction control card
VRT-V00 Remote VLF display (with 7 relays)
VRT-W00 Remote VLF display (no relays)
VRT-500 Remote relay unit (with 7 relays)
Notes:
1.
For compliance with clause 5.10 of EN 54-20 the detector shall be supplied
with power from a power supply conforming to the requirements of EN 54-4.
2.
The device is approved for sensitivity Classes A, B and C. The Class of any
pipe/hole configuration and detector sensitivity must be determined using
ASPIRE2.
3.
System design, installation and commissioning shall be performed in
accordance with the VESDA VLF product guide (07209).
4.
Remote display, programmer and relay modules are also approved in a 19
sub rack.
5.
The detector is also approved when used with in-line filter models,
E700-FILASSY and VSP-850 in accordance with the appropriate
VESDA application guide (10856 or 17785).
6.
xx denotes alternative language version where xx (range 00 to 99)
designates the language of the product labels.
7.
Alternative model number with suffix* as indicated, intended for French
market.
8.
When installing pipework systems containing in-line components, guidance
from the 18336 "Xtralis Open-flow In-Line Components" document shall be
sought and the recommendations followed.
Approved configurations:
- VLC-500 (VLF-50000-NF*) VLC Relays only (RO) version
- VLC-505 (VLF-50500-NF*) VLC VESDAnet (VN) version
- VLC-400 (VLF-400-NF*) VLC Apollo (AP) version
- VLC-700 (801519.F0*) VLC Esser (EB) version
- VLC-800 (VLF-800-NF*) VLC Tyco (MX) version
Approved remote units with the VLC-505 VESDAnet (VN) version:
- VRT-J00 Remote VLC display (with 7 relays)
- VRT-K00 Remote VLC display (no relays)
- VRT-500 Remote relay unit (with 7 relays)
Notes:
1.
For compliance with clause 5.10 of EN 54-20 the detector shall be supplied
with power from a power supply conforming to the requirements of EN 54-4.
2.
The device is approved for sensitivity Classes A, B and C. The Class of any
pipe/hole configuration and detector sensitivity must be determined using
ASPIRE2.
3.
System design, installation and commissioning shall be performed in
accordance with the VESDA VLC product guides
(10280 [VLC-500 & VLC-505], 03494 [VLC-400], 09411 [VLC-700],
09515 [VLC-800]).
4.
Remote display, programmer and relay modules are also approved in a 19
sub rack.
5.
The detector is also approved when used with in-line filter models,
E700-FILASSY and VSP-850 in accordance with the appropriate VESDA
application guide (10856 or 17785).
6.
Alternative model numbers with suffix* as indicated, intended for French
market.
7.
When installing pipework systems containing in-line components, guidance
from the 18336 "Xtralis Open-flow In-Line Components" document shall be
sought and the recommendations followed.
Approved Configurations:
VLP-012 (VLP-01200-NF*) VLP detector with Display & Programmer
VLP-002 (VLP-00200-NF*) VLP detector with Display
VLP-400 (VLP-00000-NF*) VLP detector with Fire/OK LEDs only
VLP-401 (VLP-00100-NF*) VLP detector with Programmer & Fire/OK LEDs
VLP-100 VLP detector with OEM cover
Approved remote units:
VRT-100 Remote Programmer
VRT-200 Remote VLP Display unit (with 7 relays)
VRT-300 VESDAnet socket
VRT-500 Remote Relay unit (with 7 relays)
VRT-600 Remote VLP Display unit (without relays)
Notes:
1.
For compliance with clause 5.10 of EN 54-20 the detector shall be supplied
305d/02
305d/03
305d/04
373
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
with power from a power supply conforming to the requirements of EN 54-4.
The device is approved for sensitivity Classes A, B and C. The Class of any
pipe/hole configuration and detector sensitivity must be determined using
ASPIRE2.
3.
System design, installation and commissioning shall be performed in
accordance with the VESDA VLP product guide (10278).
4.
Remote display, programmer and relay modules are also approved in a
19 sub rack.
5.
The detector is also approved when used with in-line filter models,
E700-FILASSY and VSP-850 in accordance with the appropriate
VESDA application guide (10856 or 17785).
6.
Alternative model numbers with suffix* as indicated, intended for French
market.
7.
When installing pipework systems containing in-line components, guidance
from the 18336 "Xtralis Open-flow In-Line Components" document shall be
sought and the recommendations followed.
Approved Configurations:
VLS-600 (VLS-20000-NF*) VLS with 7 relays and Fire/OK LEDs
VLS-204 (VLS-20400-NF*) VLS with 7 Relays and Display Module
VLS-214 (VLS-21400-NF*) VLS with 7 Relays, Display and Program Module
VLS-700 (VLS-30000-NF*) VLS with 12 relays and Fire/OK LEDs
VLS-304 (VLS-30400-NF*) VLS with 12 Relays and Display Module
VLS-314 (VLS-31400-NF*) VLS with 12 Relays, Display and Program Module
VLS-100 VLS with 7 Relays and OEM cover
VLS-500 VLS with 12 Relays and OEM cover
Approved Remote Units:
VRT-400 Remote Scanner Display with 7 relays
VRT-700 Remote Scanner Display with no relays
VRT-800 Remote Scanner Display with 12 relays
VRT-900 Remote Scanner Relays -12 relays
VRT-E00 Remote Scanner Relays - 7 relays
Notes:
1.
For compliance with clause 5.10 of EN 54-20 the detector shall be supplied
with power from a power supply conforming to the requirements of EN 54-4.
2.
The device is approved for sensitivity Classes A, B and C. The Class of any
pipe/hole configuration and detector sensitivity must be determined using
ASPIRE2.
3.
System design, installation and commissioning shall be performed in
accordance with the VESDA VLS product guide (10279).
4.
Remote display, programmer and relay modules are also approved in a 19
sub rack.
5.
The detector is also approved when used with in-line filter models,
E700-FILASSY and VSP-850 in accordance with the appropriate
VESDA application guide (10856 or 17785).
6.
Alternative model numbers with suffix* as indicated, intended for French
market.
7.
When installing pipework systems containing in-line components, guidance
from the 18336 "Xtralis Open-flow In-Line Components" document shall be
sought and the recommendations followed
Incorporating the following ancillary equipment:
VIC-010 VESDAnet network card
VIC-020 Multifunction control card
VIC-030 Multifunction control card
VRT-V00 Remote VLF display (with 7 relays)
VRT-W00 Remote VLF display (no relays)
VRT-500 Remote relay unit (with 7 relays)
Notes:
1.
For compliance with clause 5.10 of EN 54-20 the detector shall be supplied
with power from a power supply conforming to the requirements of EN 54-4.
2.
The device is approved for sensitivity Classes A, B and C. The Class of any
pipe/hole configuration and detector sensitivity must be determined using
ASPIRE2.
3.
System design, installation and commissioning shall be performed in
accordance with the VESDA VLF product guide (07208).
4.
Remote display, programmer and relay modules are also approved in a 19
sub rack.
5.
The detector is also approved when used with in-line filter models,
E700-FILASSY and VSP-850 in accordance with the appropriate
VESDA application guide (10856 or 17785).
6.
xx denotes alternative language version where xx (range 00 to 99)
designates the language of the product labels.
7.
Alternative model number with suffix* as indicated, intended for French
2.
VESDA VLS High
sensitivity aspirating smoke
detector
VESDA VLF-250-xx (VLF250-01NF*) high sensitivity
aspirating smoke detector
374
305d/05
305d/06
20 Oct 2014
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
LPCB Ref.
No.
market.
When installing pipework systems containing in-line components, guidance
from the 18336 "Xtralis Open-flow In-Line Components" document shall be
sought and the recommendations followed.
Incorporating the following ancillary equipment:
VIC-010 VESDAnet network card
VIC-020 Multifunction control card
VIC-030 Multifunction control card
VRT-V00 Remote VLF display (with 7 relays)
VRT-W00 Remote VLF display (no relays)
VRT-500 Remote relay unit (with 7 relays)
Notes:
1.
For compliance with clause 5.10 of EN 54-20 the detector shall be supplied
with power from a power supply conforming to the requirements of EN 54-4.
2.
The device is approved for sensitivity Classes A, B and C. The Class of any
pipe/hole configuration and detector sensitivity must be determined using
ASPIRE2.
3.
System design, installation and commissioning shall be performed in
accordance with the VESDA VLF product guide (07209).
4.
Remote display, programmer and relay modules are also approved in a 19
sub rack.
5.
The detector is also approved when used with in-line filter models,
E700-FILASSY and VSP-850 in accordance with the appropriate
VESDA application guide (10856 or 17785).
6.
xx denotes alternative language version where xx (range 00 to 99)
designates the language of the product labels.
7.
Alternative model number with suffix* as indicated, intended for French
market.
8.
When installing pipework systems containing in-line components, guidance
from the 18336 "Xtralis Open-flow In-Line Components" document shall be
sought and the recommendations followed.
Approved configurations:
- VLC-500 (VLF-50000-NF*) VLC Relays only (RO) version
- VLC-505 (VLF-50500-NF*) VLC VESDAnet (VN) version
- VLC-400 (VLF-400-NF*) VLC Apollo (AP) version
- VLC-700 (801519.F0*) VLC Esser (EB) version
- VLC-800 (VLF-800-NF*) VLC Tyco (MX) version
Approved remote units with the VLC-505 VESDAnet (VN) version:
- VRT-J00 Remote VLC display (with 7 relays)
- VRT-K00 Remote VLC display (no relays)
- VRT-500 Remote relay unit (with 7 relays)
Notes:
1.
For compliance with clause 5.10 of EN 54-20 the detector shall be supplied
with power from a power supply conforming to the requirements of EN 54-4.
2.
The device is approved for sensitivity Classes A, B and C. The Class of any
pipe/hole configuration and detector sensitivity must be determined using
ASPIRE2.
3.
System design, installation and commissioning shall be performed in
accordance with the VESDA VLC product guides
(10280 [VLC-500 & VLC-505], 03494 [VLC-400], 09411 [VLC-700],
09515 [VLC-800]).
4.
Remote display, programmer and relay modules are also approved in a 19
sub rack.
5.
The detector is also approved when used with in-line filter models,
E700-FILASSY and VSP-850 in accordance with the appropriate VESDA
application guide (10856 or 17785).
6.
Alternative model numbers with suffix* as indicated, intended for French
market.
7.
When installing pipework systems containing in-line components, guidance
from the 18336 "Xtralis Open-flow In-Line Components" document shall be
sought and the recommendations followed.
Approved Configurations:
VLP-012 (VLP-01200-NF*) VLP detector with Display & Programmer
VLP-002 (VLP-00200-NF*) VLP detector with Display
VLP-400 (VLP-00000-NF*) VLP detector with Fire/OK LEDs only
VLP-401 (VLP-00100-NF*) VLP detector with Programmer & Fire/OK LEDs
VLP-100 VLP detector with OEM cover
Approved remote units:
VRT-100 Remote Programmer
VRT-200 Remote VLP Display unit (with 7 relays)
VRT-300 VESDAnet socket
VRT-500 Remote Relay unit (with 7 relays)
8.
VESDA VLF-500-xx (VLF500-01NF*) high sensitivity
aspirating smoke detector
VESDA VLC High
sensitivity aspirating smoke
detector
VESDA VLP High
sensitivity aspirating smoke
detector
20 Oct 2014
305d/07
305d/08
305d/09
375
PART 1: SECTION 4.1
COMMERCIAL DETECTORS
Certificated Products
VESDA VLS High
sensitivity aspirating smoke
detector
XCC-010 (XCC-01000-NF)
XCC-010 (XCC-01000-NF)
376
LPCB Ref.
No.
VRT-600 Remote VLP Display unit (without relays)
Notes:
1.
For compliance with clause 5.10 of EN 54-20 the detector shall be supplied
with power from a power supply conforming to the requirements of EN 54-4.
2.
The device is approved for sensitivity Classes A, B and C. The Class of any
pipe/hole configuration and detector sensitivity must be determined using
ASPIRE2.
3.
System design, installation and commissioning shall be performed in
accordance with the VESDA VLP product guide (10278).
4.
Remote display, programmer and relay modules are also approved in a
19 sub rack.
5.
The detector is also approved when used with in-line filter models,
E700-FILASSY and VSP-850 in accordance with the appropriate
VESDA application guide (10856 or 17785).
6.
Alternative model numbers with suffix* as indicated, intended for French
market.
7.
When installing pipework systems containing in-line components, guidance
from the 18336 "Xtralis Open-flow In-Line Components" document shall be
sought and the recommendations followed.
Approved Configurations:
VLS-600 (VLS-20000-NF*) VLS with 7 relays and Fire/OK LEDs
VLS-204 (VLS-20400-NF*) VLS with 7 Relays and Display Module
VLS-214 (VLS-21400-NF*) VLS with 7 Relays, Display and Program Module
VLS-700 (VLS-30000-NF*) VLS with 12 relays and Fire/OK LEDs
VLS-304 (VLS-30400-NF*) VLS with 12 Relays and Display Module
VLS-314 (VLS-31400-NF*) VLS with 12 Relays, Display and Program Module
VLS-100 VLS with 7 Relays and OEM cover
VLS-500 VLS with 12 Relays and OEM cover
Approved Remote Units:
VRT-400 Remote Scanner Display with 7 relays
VRT-700 Remote Scanner Display with no relays
VRT-800 Remote Scanner Display with 12 relays
VRT-900 Remote Scanner Relays -12 relays
VRT-E00 Remote Scanner Relays - 7 relays
Notes:
1.
For compliance with clause 5.10 of EN 54-20 the detector shall be supplied
with power from a power supply conforming to the requirements of EN 54-4.
2.
The device is approved for sensitivity Classes A, B and C. The Class of any
pipe/hole configuration and detector sensitivity must be determined using
ASPIRE2.
3.
System design, installation and commissioning shall be performed in
accordance with the VESDA VLS product guide (10279).
4.
Remote display, programmer and relay modules are also approved in a 19
sub rack.
5.
The detector is also approved when used with in-line filter models,
E700-FILASSY and VSP-850 in accordance with the appropriate
VESDA application guide (10856 or 17785).
6.
Alternative model numbers with suffix* as indicated, intended for French
market.
7.
When installing pipework systems containing in-line components, guidance
from the 18336 "Xtralis Open-flow In-Line Components" document shall be
sought and the recommendations followed
Xtralis Class C aspirating smoke detector
Notes:
1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied
with power from a power supply conforming with the requirements of EN 54-4.
2. System design, installation and commissioning shall be performed in
accordance with the Xtralis Class C XCC-010 product guide (Document 14159).
3. The device is approved for sensitivity Class C.
4. The detector is also approved when used with in-line filter models,
E700-FILASSY and VSP-850 in accordance with the appropriate VESDA
application guide (10856 or 17785).
5. When installing pipework systems containing in-line components, guidance
from the 18336 "Xtralis Open-flow In-Line Components" document shall be
sought and the recommendations followed.
6. XCC-01000-NF alternative model number intended for French market.
Xtralis Class C aspirating smoke detector
Notes:
1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied
with power from a power supply conforming with the requirements of EN 54-4.
2. System design, installation and commissioning shall be performed in
accordance with the Xtralis Class C XCC-010 product guide (Doc