CHANGING LAMP AND CLEANING
Isolate power supply before starting work.
Allow lamp to cool. Pull lamp to remove DO NOT TWIST. Insert new lamp.
To remove the bezel, simply twist anti-clockwise.
Wash bezel and splashguard in warm soapy water. Do not use abrasive cleaners. Clean
dust from body with a dry brush. Refit bezel.
Cleaning intervals will vary according to operating conditions. We recommend that fans
be cleaned once a year to maintain efficiency and reliability.
Installation Instructions
WARNING: Failure to comply with these instructions may invalidate the warranty.
IPX4
(Installed with Spotvent splashguard fitted)
INPUT
OUTPUT
Lamp Transformer
230v ac ~
12v ac ~
INPUT
Sealed Dichroic Lamp
12v ac ~ 35 Watts
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Spotvent Diffuser & Lamp Unit
(WITH SPLASHGUARD)
Manufactured in the UK by
Polypipe
Sandall Stones Road, Kirk Sandall Industrial Estate, Kirk Sandall, Doncaster DN3 1QR
Tel: +44 (0) 8443 715523 Fax: +44 (0) 8443 715524
www.polypipe.com/ventilation
ISSUE 3
19/05 LAB997R
Polypipe
SILAVENT SPOTVENT DIFFUSER & LAMP UNIT
Silavent’s SPOTVENT is a stylish unit designed to illuminate and ventilate a shower
cubicle, wash basin or many other areas. SPOTVENT combines 12v lighting with an
extract grille and may be used in conjunction with Silavent in-line fans for effective
ventilation of shower cubicles.
Wiring Instructions
It is recommended that the fans be connected into the lighting circuit, with double pole
(3mm) isolation provided before the room light switch and suitably fused, in accordance
with current IEE Regulations.
Duct mounted fans for fixed wiring should be connected to the power supply via a
cable with solid conductors of 1mm2 to 1.5mm2 only.
SPOTVENT Product Codes
Light Fitting Only
SPV801 TWCG
Spotvent 100
Spotvent 100
SPV801 ETWCG
SPV802 ETWCG
Spotvent 120
Spotvent 120
SPV811 ETWCG
SPV812 ETWCG
Spotvent PRO
Spotvent PRO
SPV831 ETWCG
SPV832 ETWCG
N
L
FAN
Isolator Switch
Operating Switch
SPOTVENT
Transformer
12v AC~
N
L S/L
L = LIVE
N = NEUTRAL
S/L = SWITCH LIVE
Installing SPOTVENT
Cut a 120mm hole in the ceiling in the required position, making sure that there is
sufficient clearance around the joists etc. Pull the ducting and power supplies through
the hole. The ducting may be secured using a tie wrap or duct tape.
Wiring with transformer only.
The self fixing clamps are designed for use with plasterboard. First, slacken the clamps
and fold them tightly against the body of the diffuser, insert the diffuser into the hole and
tighten the clamp screws. The clamps should open and hold the diffuser firmly in
position. Do not over-tighten the clamp screws. To remove the diffuser, simply reverse
the procedure.
Isolator Switch
SPOTVENT
12v AC~
To fit the SPOTVENT splashguard, simply clip into the inner ring of the bezel and align
the rays of the splashguard with the inner ring support arms.
N
Transformer
L
Operating Switch
L
N
= LIVE
= NEUTRAL
All wiring should be in accordance with IEE Regulations.
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN.
Maximum Operating Room Temperature – 40ºC
WARNING : ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK
NOTE :
SPOTVENT is intended for use in conjunction with an extractor fan.
WARNING : ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK