Data Sheet MSP 1000 Platform - Management Agents NM3 and NM3+ Overview

Transcription

Data Sheet MSP 1000 Platform - Management Agents NM3 and NM3+ Overview
Data Sheet
MSP 1000 Platform - Management Agents
NM3 and NM3+
Overview
NM3 and NM3+ are the next generation of Management Modules for the MICROSENS
MSP 1000 Platform. They form the link between the transponder modules of the xWDMsystem and the external management applications. NM3 and NM3+ replace the previous
Management Modules NM1 and NM2.
The increasing requirements of the market regarding security in optical networks have
been the crucial factor for this development. As a result the new Management Modules
offer high secure protocols like SNMP V3, SSH, SFTP, or HTTPS and support central user
authentication via RADIUS and TACACS+. To protect against manipulations the firmware
updates are encrypted and signed.
As NM3 and NM3+ Management Modules are equipped with two SFP ports, several MSP
1000 Platform chassis may be cascaded via optical channels to create a failure tolerant
ring. If one node fails, the network connectivity is re-established in about 50 milliseconds,
so all other nodes stay accessible. The ring functionality is fully compatible with the
MICROSENS industry switches of the Profi Line, Profi Line+ and Profi Line Modular series.
©2013_MICROSENS GmbH & Co. KG_Küferstr. 16_59067 Hamm/Germany_www.microsens.com
Preliminary_Data Sheet_MSP 1000 Platform - Management Agents NM3/NM3+ Page 2/5
The NM3 Management Module takes up one system slot and provides a 4-Port Gigabit
Ethernet switch. The NM3+ requires two slots and offers in total 6 Gigabit Ethernet ports,
one USB expansion port and four potential free digital alarm contacts. Both modules are
equipped with a serial RS-232 terminal port for standard RJ-45 console cable.
Ethernet network loops will be detected and prevented by an integrated protective mechanism. Redundant network paths will be automatically recognized by the Rapid Spanning
Tree Protocol (RSTP). Virtual LANs (VLANs) with up to 256 VLAN IDs may be configured.
Furthermore the Management Modules NM3 and NM3+ support the Link Layer Discovery
Protocols (LLDP).
For a detailed list of the available software features see the associated document
“Firmware Feature List Generation 6 Ethernet Switches” in its latest version.
Features
Network Management
Connectors
 Web Manager (HTTP/HTTPS)
Up-/Downlinks
 2x SFP-Slot 100/1000Base-X
 Command Line Interface via
Telnet/SSH/Console, incl. standardcommandos (ping, traceroute etc.)
 SNMP v1/v2c/v3 with
View-based Access Control Model
(VACM) and User-based Security Model
(USM)
 Central management platform
(NMP Standard / NMP Professional /
NMP Server)
Local Ports
 2x 10/100/1000Base-T RJ-45 (NM3)
4x 10/100/1000Base-T RJ-45 (NM3+)
 Auto-Negotiation
 Auto MDI/MDI-X function for the use of
uniform patch cables
RS-232 Console Port
 Serial terminal port for CLI access
 IPv4/IPv6 Dual Stack
 RJ-45 port for standard console cable
 Powerful microScript language for the
automation of routine processes by CLI
script
USB Extension Port (on NM3+)
 Firmware-, Script- and / or configuration files can be loaded, stored and
executed direct from the switch (via
FTP, SFTP, TFTP)
 Incremental firmware updates
 Network Time Protocol (NTP)
System
 Linux operating system with short
system boot time (about 20 sec.)
 For optional accessories
Alarm contacts / I/O-Ports (on NM3+)
 Potential free digital input / output ports
 2x output (relay)
 2x input (opto coupler)
Mounting
 Module in Euro card format for MSP
1000 Platform chassis with knurled
screws in the front panel
 Uses one (NM3) / two slots (NM3+)
 Modular microSD memory card for configuration, CLI scripts, firmware
©2013_MICROSENS GmbH & Co. KG_Küferstr. 16_59067 Hamm/Germany_www.microsens.com
Preliminary_Data Sheet_MSP 1000 Platform - Management Agents NM3/NM3+ Page 3/5
Technical Specifications
Type
MSP 1000 Platform – Management Agent NM3 / NM3+
Twisted-Pair Ports
NM3:
2x 10/100/1000BaseT (RJ-45)
NM3+: 4x 10/100/1000BaseT (RJ-45)
1x RS-232 serial console port (RJ-45)
Optical Interfaces:
2x SFP Slot 100/1000Base-X (LC)
Possible wavelength: any
Temperature
0°C … +40°C
-40°C … +85°C
Dimensions (H x W x D)
NM3:
(Operating)
(Storage)
Approx. 129 x 25 x 190 mm (1 Slot)
NM3+: Approx. 129 x 50 x 190 mm (2 Slot)
Weight
NM3:
~ 180 g
NM3+: ~ 270 g
Certifications
CE/FCC
Web Access
The integrated Web server (HTTP/HTTPS) provides full access to all features and enables
comfortable use of the MSP 1000 xWDM-System without the need to install special software. It allows e.g. carriers to use the comprehensive NMP for configuration and fault
management while customers may use the web access to monitor ‘their’ system. For
such purpose the web access can be precisely adjusted for each user with ‘Read’, ‘Write’
or ‘Limited’ access - individually for all features. The web server may also be shut down
completely.
Similar to NMP the same data such as serial numbers, optical power level or statistics are
displayed.
SNMP
The SNMP data for all MSP 1000 Modules in the xWDM-System are created within the
Management Agent Module and do not require an external support through a Management System such as NMP. Therefore SNMP is fully independent and provides a redundant alternative management path.
SNMP (ALARM) trap generation to any number of IP destinations
Integrated Web browser
Encoding on textual and object basis
Private MIBs and MIB-II support plus diverse standard MIBs
Full access to all details like power level, statistics or serial numbers
Integrated in diverse management systems
“Are You Alive” function permits non-invasive trap
©2014_MICROSENS GmbH & Co. KG_Küferstr. 16_59067 Hamm/Germany_www.microsens.com
Preliminary_Data Sheet_MSP 1000 Platform - Management Agents NM3/NM3+ Page 4/5
Security / Authentication
With the implemented user model the access rights for each user can be precisely tailored – analogue to the SNMP V3 ‘View-based Access Control Model’. This access view
model may be applied to SNMP V1 or V2c access, practically creating SNMP V3 like
access protection, but without whose complexness.
The integrated central RADIUS server allows user authentication (according to IEEE
802.1X) based on username/password, certificate or MAC address.
Furthermore users can be authenticated by the central TACACS+ server and user access
may be restricted via Access Control List (ACL).
Local user management with various options is also available.
Memory Card
The microsSD memory card is used for the permanent storage of configuration, script
and firmware files. Therefore it is possible to transfer the complete configuration to a
new device by swapping the memory card e.g. in case of service. Herewith potential incompatibilities according to different device versions are avoided.
Optionally it is possible to store the MAC address to the microSD memory card, so it will
also migrate to the new device by swapping the memory card.
During operation the memory card is protected against removal and the fault tolerant
journaling file system ensures reliability and stability.
Only by using original MICROSENS industrial grade memory cards the long term system
availability and stability over the complete temperature range can be guaranteed.
Alarm Contacts
Galvanic isolated contacts (2x)
Galvanic isolated digital inputs (2x)
The potential free output contacts (Signal out
1+2) allows to control external signalling devices to show the alarm and operation status.
The potential free input contacts (Signal In
1+2) allow the direct monitoring of external
systems, e.g. a rack or door monitoring
system.

Relay contact, maximum load 57 V / 1 A

Isolation voltage to the device 1.500 V DC

2x galvanic isolated, digital input

Normally open or normally closed contact
available

Internal opto coupler, Input voltage
12 to 57 V DC

Attention:
Not suitable for the direct connection
of 230 V AC devices!

Isolation voltage 1.500 V DC

Status monitored via management

Changes will cause freely definable traps
and scripts
©2014_MICROSENS GmbH & Co. KG_Küferstr. 16_59067 Hamm/Germany_www.microsens.com
Preliminary_Data Sheet_MSP 1000 Platform - Management Agents NM3/NM3+ Page 5/5
Order Information
Description
Article No.:
MSP 1000 Platform – Management Agent
NM3 Management Agent Module, SNMP (v1/v2/v3), Web Server
(http/ https), 2x 10/100/1000T RJ-45 Port, 1x RS-232 Console
Port RJ-45 (Telnet/SSH), 2x SFP Slots (100/1000X), Ring
Redundancy, microSD Memory Card
MS425523M
NM3+ Management Agent Module, SNMP (v1/v2/v3), Web
Server (http/https), 4x 10/100/1000T RJ-45 Port, 1x RS-232
Console Port RJ-45 (Telnet/SSH), 2x SFP Slot (100/1000X),
Ring Redundancy, USB Port, microSD Memory Card, I/Os: 2x
In, 2x Out
MS425524M
microSD Memory Card 4 GB for MICROSENS G6-Switches,
Extended temperature range -25°C up to +85°C, Standard
MS140894X-4G
Accessories
Description
Article No.:
SFP Transceiver (Fast Ethernet & WDM on request)
SFP Transceiver, Gigabit Ethernet, Digital Diagnostic
850 nm Multimode, 1000Base-SX, LC duplex
Extended temperature range -25°C up to +85°C
MS100200DX
SFP Transceiver, Gigabit Ethernet, Digital Diagnostic
1310 nm Monomode, 1000Base-LX, LC duplex
Extended temperature range -25°C up to +85°C
MS100210DX
Network Management
NMP Professional – Network Management Platform
Software incl. one year update license
MS200160-1
NMP Professional – additional update license for n years
MS200161-n
NMP Standard– Network Management Platform
Software incl. one year update license
MS200162-1
NMP Standard – additional update license for n years
MS200163-n
NMP Server – Network Management Platform
Software incl. one year update license and 5 clients
MS200164-1
NMP Server – additional update license for n years
MS200165-n
This document in whole or in part may not be duplicated, reproduced, stored or retransmitted without prior written permission of MICROSENS GmbH & Co.
KG. All information in this document is provided ‘as is’ and subject to change without notice. MICROSENS GmbH & Co. KG disclaims any liability for the
correctness, completeness or quality of the information provided, fitness for a particular purpose or consecutive damage.
MICROSENS is a trademark of MICROSENS GmbH & Co. KG. Any product names mentioned herein may be trademarks and/or registered trademarks of
their respective companies. AV MS42552x_MP1_NM3_DAT_EN_V1.0.0_Preliminary
©2014_MICROSENS GmbH & Co. KG_Küferstr. 16_59067 Hamm/Germany_www.microsens.com