Communication system (pdf 47KB)

Transcription

Communication system (pdf 47KB)
TN 109: 2014
For queries regarding this document
[email protected]
www.asa.transport.nsw.gov.au
Technical Note
TN 109: 2014
Issued date
Effective date
19 December 2014
19 December 2014
Subject:
Superseded standard – Minimum Operating Standards
for Rolling Stock
This Technical Note is to advise that the RailCorp engineering standard ESR 0001 Minimum
Operating
Standard
for
Rolling
Stock
has
been
superseded
by
ASA
standard
T HR RS 00000 ST. The standard has been superseded as follows:
•
ESR 0001 – 000 superseded by T HR RS 00000 ST
•
ESR 0001 – 100 superseded by T HR RS 00100 ST
•
ESR 0001 – 200 superseded by T HR RS 00200 ST
•
ESR 0001 – 300 superseded by T HR RS 00300 ST
•
ESR 0001 – 400 superseded by T HR RS 00400 ST
•
ESR 0001 – 500 superseded by T HR RS 00500 ST
•
ESR 0001 – 600 superseded by T HR RS 00600 ST
•
ESR 0001 – 700 superseded by T HR RS 00700 ST
•
ESR 0001 – A1 superseded by T HR RS 00811 ST
•
ESR 0001 – A2 superseded by T HR RS 00812 ST
•
ESR 0001 – A3 superseded by T HR RS 00813 ST
•
ESR 0001 – A4 superseded by T HR RS 00814 ST
•
ESR 0001 – A5 superseded by T HR RS 00815 ST
•
ESR 0001 – A6 superseded by T HR RS 00816 ST
•
ESR 0001 – A7 superseded by T HR RS 00817 ST
A3929638
© State of NSW through Transport for NSW
Asset Standards Authority
Page 1 of 2
TN 109: 2014
•
ESR 0001 – B superseded by T HR RS 00820 ST
•
ESR 0001 – C superseded by T HR RS 00830 ST
•
ESR 0001 – D superseded by T HR RS 00840 ST
•
ESR 0001 – E superseded by T HR RS 00850 ST
•
ESR 0001 – F superseded by T HR RS 00860 ST
•
ESR 0001 – G superseded by T HR RS 00870 ST
•
ESR 0001 – H superseded by T HR RS 00880 ST
•
ESR 0001 – I superseded by T HR RS 00890 ST
The ASA Minimum Operating Standards for Rolling Stock can be found in the following location
on the ASA website under rolling stock:
http://www.asa.transport.nsw.gov.au/ts/asa-standards#rolling-stock
Authorisation
Technical content
prepared by
Checked and
approved by
Interdisciplinary
coordination
checked by
Authorised for
release
Name
Jakub Zawada
Michael Uhlig
David Spiteri
Graham Bradshaw
Position
Principal Engineer,
Rolling Stock Access
Integrity
Lead Engineer,
Rolling Stock
Chief Engineer Rail
Principal Manager
Network Standards &
Services
Signature
A3929638
© State of NSW through Transport for NSW
Asset Standards Authority
Page 2 of 2
ESR 0001-F
RSU APPENDIX F COMMUNICATION
SYSTEM
Version 1.0
Issued June 2010
Owner:
Chief Engineer Rolling Stock
Approved
by:
Stephen White,
Technical Specialist Rolling
Stock Performance Standards,
Rolling Stock Access Integrity
Authorised
by:
Michael Uhlig,
Manager
Rolling Stock Access Integrity
Disclaimer
This document was prepared for use on the RailCorp Network only.
RailCorp makes no warranties, express or implied, that compliance with the contents of this document shall be
sufficient to ensure safe systems or work or operation. It is the document user’s sole responsibility to ensure that the
copy of the document it is viewing is the current version of the document as in use by RailCorp.
RailCorp accepts no liability whatsoever in relation to the use of this document by any party, and RailCorp excludes
any liability which arises in any manner by the use of this document.
Copyright
The information in this document is protected by Copyright and no part of this document may be reproduced, altered,
stored or transmitted by any person without the prior consent of RailCorp.
UNCONTROLLED WHEN PRINTED
Page 1 of 4
Engineering Standard
Superseded by T HR RS 00860 ST
Engineering Standard
Rolling Stock
Superseded by T HR RS 00860 ST
RailCorp Engineering Standard — Rolling Stock
RSU AppendiX F Communication system
ESR 0001-F
Document control
Revision
Date
Summary of change
1.0
June 2010
Reformatted and renumbered ESR 0001-F
Summary of changes from previous version
Summary of change
Section
NOTE – If the final document is small enough for the ‘Contents’ and ‘Document control’
to fit on one page remove the page break between the existing pages 2 and 3.
HOWEVER if the ‘Document control’ page carries over to a second page separate
pages must be used for ‘Contents’ and ‘Document control’
Contents
1 Introduction........................................................................................................................................3
1.1 Copper communication cables..................................................................................................3
1.1.1 Cable construction and installation. .............................................................................3
2 Railway radio systems......................................................................................................................3
3 Interference tests ..............................................................................................................................4
© Rail Corporation
Issued June 2010
UNCONTROLLED WHEN PRINTED
Page 2 of 4
Version 1.0
Superseded by T HR RS 00860 ST
RailCorp Engineering Standard — Rolling Stock
RSU AppendiX F Communication system
1
ESR 0001-F
Introduction
Vehicles and trains shall generate no energy capable of interfering with the RailCorp
signalling and communications equipment.
1.1
Copper communication cables
Copper communications cables are primarily used for local distribution of services from
nodes fed by optic fibre cables. These services include both telephone and digital data
services.
Frequencies in use range from D.C. to 2 MHz plus harmonics.
1.1.1
Cable construction and installation.
New cable is of unit twin, jelly filled construction, with a moisture barrier sheath but no
screening. The capacitance unbalance to earth for these cables is typically less than 1%.
There is a small (and decreasing) amount of screened quad cable still in use.
In the Sydney metropolitan area many of the cable routes are above ground in troughing
and drawings are not always available. Cable route plans of buried cables are available if
required. Cable routes may be anywhere within (and at times are outside) the railway
easement, but are typically close to the boundary fence line on one or both sides of the
easement.
2
Railway radio systems
Radio systems to be considered from an interference viewpoint include MetroNet, WB,
GRN, Police Radio, Station Radio and Worksite Radio.
MetroNet operates in the 403 – 420 MHz band on 12.5kHz spaced analogue channels.
WB is a simplex single analogue channel system operating at 450.05 MHz.
GRN operates in the 403 – 420 MHz band on 12.5kHz spaced analogue channels,
migrating to digital.
Police Radio operates in the 450 – 470 MHz band on 12.5kHz spaced analogue
channels, migrating to digital.
Station Radio operates in the 400 – 470 MHz band on 12.5kHz spaced analogue
channels.
Worksite Radio operates in the 450 – 470 MHz band on 12.5kHz spaced analogue
channels.
© Rail Corporation
Issued June 2010
UNCONTROLLED WHEN PRINTED
Page 3 of 4
Version 1.0
Superseded by T HR RS 00860 ST
RailCorp Engineering Standard — Rolling Stock
RSU AppendiX F Communication system
3
ESR 0001-F
Interference tests
Type tests shall be conducted using the train set to measure vehicle generated
disturbance effects in signalling track circuits, telecommunication cables and lineside
telecommunications systems.
Refer to ESR 0001 – 200, Section 33 (RSU 296) Signal and Communication Interference
Tests and to RailCorp Signalling Standard ESG 006 Rolling Stock Signalling Interface
Requirements.
© Rail Corporation
Issued June 2010
UNCONTROLLED WHEN PRINTED
Page 4 of 4
Version 1.0