Fully Enclosed Wide Distribution Industrial

Transcription

Fully Enclosed Wide Distribution Industrial
97
Fully Enclosed Wide Distribution Industrial
T5 | T8
SPECIFICATIONS
•• Enclosure – Outer housing consists of 5VA (f1)
fiberglass, rated for flame and weather resistance.
•• Internal Housing – 25-gauge die-formed C.R.S.
with 92% minimum average reflective white
polyester powder coat bonded to phosphate-free,
multi-stage pretreated metal. All C.R.S. parts
painted after fabrication to facilitate installation,
increase efficiency, and inhibit corrosion.
•• Latching – Injection-molded polycarbonate
latches.
•• Reflector – 95% reflective highly specular
aluminum.
97
EXAMPLE
-
t SERIES
4
t
-
2 32
t
-
t
A
t
-
NOMINAL TOTALWATTAGE/ SHIELDING
LENGTH LAMPS TYPE
OP TIONS
-
t
E B2
t
OPTIONS/
ACCESSORIES
BALLAST
TYPE
-
•• Shielding – Clear, 100% acrylic, impact-resistant,
UV resistant, injection-molded diffuser with
frosted ends.
•• Electrical – Electronic ballast standard, instant
start T8, program start T5, rated Class P.
•• Mounting – Surface or suspended. Stainless steel
ceiling mounting bracket standard.
•• Labels & Certifications – UL/CUL listed as
fluorescent luminaire suitable for dry or damp
locations. UL/CUL listed as suitable for wet
locations when specified with watertight hub,
STOW cord, or mini-male receptacle option.1 NSF/
ANSI Standard 2–Splash Zone certified, IP65 and
IP672 certified.
UNV
t
VOLTAGE
COMPONENT
FEATURES
ORDERING INFORMATION
•• Fully gasketed fixture resists dust,
SERIES
••
••
••
••
••
bugs, and moisture.
Polycarbonate toggle latches (standard)
ensure a tight seal and easy access to
electrical components.
Optional stainless steel, tamperresistant stainless steel, or tamperresistant polycarbonate latches
available.
Wet location listed when specified with
qualified options.1
Closed-cell polyurethane gasket
poured and formed in place to ensure
tight seal—does not absorb water or
promote fungal growth.
This fixture is proudly made in the USA.
97
4 8 4’
8’
2 or 4 (2-lamp cross-section)
LAMP WATTAGE/TYPE
28T5S
32
54T5H
59
4’, 28-watt T5 (2-lamp ballast only)
4’, 32-watt T8
4’, 54-watt T5HO
8’, 59-watt T8
SHIELDING
FR
Clear, 100% acrylic, impactresistant diffuser with frosted ends
Frosted, 100% acrylic, impactresistant diffuser
OPTIONS/ACCESSORIES
Nominal Length
4’
8’
Overall Length
51-7/8”
100-1/4”
QUANTITY ESTIMATOR
Item #: 97-4-232-A
Room Size
20’ x 20’ (400 sq. ft.)
50’ x 50’ (2500 sq. ft.)
100’ x 100’ (10000 sq. ft.)
± 35 fc.
6
25
90
± 50 fc.
9
36
132
± 75 fc.
12
56
196
For generic EM ballast options (must specify
voltage), see page 231.1
3WC6
3-wire, 6’ STOW cord
3WC20
3-wire, 20’ STOW cord
4WC6
4-wire, 6’ STOW cord
4WC20
4-wire, 20’ STOW cord
3-wire mini-male receptacle only
3WMR
3WMRC6 3-wire mini-male receptacle with
6’ STOW cord
3WMRC20 3-wire mini-male receptacle with
20’ STOW cord
4WMR
4-wire mini-male receptacle only
4WMRC6 4-wire mini-male receptacle with 6’
STOW cord
4WMRC20 4-wire mini-male receptacle with
20’ STOW cord
WET/1
(1) 1/2” watertight hub (factoryinstalled in end of housing)
Calculations based on standard reflectance of 80/50/20 and a light
loss factor of .85 with a 10’-0” ceiling height.
72
| Industrial
(2) 1/2” watertight hubs
(factory-installed in ends of
housing; not available with
occupancy sensor option)
SSCMB
Stainless steel chain mounting
brackets (2 per fixture)
HA/40C 3 High-ambient, 40ºC max.
operating temp. 3
GMF 4 Fuse, slow blow (specify
voltage) 4
4
GLR Fuse, fast blow (specify
voltage) 4
5
TP Tamper-resistant
polycarbonate latches 5
SS LATCH
Stainless steel latches
TP/SS LATCH 5 Tamper-resistant stainless
steel latches 5
OCCUPANCY SENSORS 2
Occupancy sensor must be specified from the
following (specify voltage):
OCCWS HB350W-L3W-120/2772
OCCWS HB350W-L4W-120/2772
TOTAL LAMPS
3/8”
5-1/2”
WET/2
NOMINAL LENGTH
A
6-3/4”
OPTIONS/ACCESSORIES (Continued)
Fully Enclosed Wide Distribution
Industrial
LGV30864.013013RJ
BALLAST TYPE
See page 230 for complete ballast offering.
EB2
2-lamp electronic ballast
4-lamp electronic ballast
EB4
(2) 2-lamp electronic ballasts
EB2/2
VOLTAGE
120
277
UNV
1
2
3
4
5
120V
277V
120-277V
347
480
347V
480V
(T5HO only)
EM ballast for enclosed and gasketed fixtures is
required for fixture to be suitable for wet locations (not
available with HA/40C option).
Fixture is IP65 certified when specified with occupancy
sensor.
Amalgam lamps recommended. HA/40C option not available
with EM ballast.
Two (2) fuses required when specifying 208V or 240V.
This option requires a tamper-resistant tool (must be
ordered separately). Please specify quantity required per
project.