Double acting pneumatic actuator for 90° operation for On
Transcription
Double acting pneumatic actuator for 90° operation for On
RPD Pneumatic Actuator Double acting pneumatic actuator for 90° operation for On-Off and Modulating heavy duty service General The RPD pneumatic actuator series was engineered and is manufactured to provide maximum torque output with minimum supply pressure. Simplicity, reliability and economy are at the top of the list of design parameters. The RPD actuator is suitable for any quarter turn application such as ball, plug, butterfly valves or dampers, in both On-Off and Modulating heavy duty service. Features • Totally enclosed, weatherproof housing in nodular cast iron for maximum strength and suitable for use in hostile environments • A compact rack and pinion design provides simple construction and constant output torque throughout the 90° stroke • An adjustable bronze sliding block supports the transverse force exerted on the rack by its engagement with the pinion • Rack and pinion in nodular cast iron, output shaft in alloy steel for maximum strength • The rack is nitrided for minimal friction • External travel stops for precise angular stroke adjustment between 80° and 100° • Electroless nickel plated and polished cylinder and output shaft for corrosion resistance and minimal friction • Floating type piston seals for low hysteresis and high sensitivity, preventing sticking problems • Lever or jackscrew manual override - An extensive range of accessories is available: - limit switch boxes - explosionproof, intrinsically safe and/or weatherproof - limit switches can be provided in different types according to customer requirements - position transmitters - explosionproof, intrinsically safe and/or weatherproof - air conditioners - air storage tanks ISPESL stamped. Tanks in accordance with different codes (ASME VIII, div. 1, SNCT, BS, TÜV, etc.) on request - solenoid valves - explosionproof, intrinsically safe and/or weatherproof - control valves, flow regulators, quick exhaust valves - positioners - pneumatic or electropneumatic - pressure switches - pneumatic or electric www.tycovalves-eu.com - terminals enclosures, pushbutton panels explosionproof or intrinsically safe and/or weatherproof • Special coatings for offshore or corrosive environments Tyco reserves the right to change the content without notice BIFRM-0017-EN-0506 RPD Pneumatic Actuator 14 13 17 11 4 8 2 1 9 10 15 16 10 9 12 16 3 6 7 5 Materials of construction Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Technical data Name Material Equivalence to U.S. standards Housing Shaft Rack Pinion Sliding block Thrust bearing screw Sealing washer Shaft seal ring Travel stop screw Sealing washer Cylinder tube Piston Piston guide sliding ring Piston seal ring End flange Cylinder gasket Tie rod Nodular cast iron Alloy steel (Nickel plated) Nodular cast iron Nodular cast iron Bronze Carbon steel PVC Nitrile rubber Carbon steel PVC Carbon steel (Nickel plated) Carbon steel Teflon + Graphite Nitrile rubber Carbon steel Nitrile rubber Alloy steel ASTM A536 gr 65 - 45 AISI SAE 9840 ASTM A536 gr 65 - 45 ASTM A536 gr 65 - 45 ASTM B427 Alloy UNS AISI SAE 1040 Tyco reserves the right to change the content without notice - 12 - 12 - 12 No C90800 AISI SAE 1040 API 5LX gr X52 ASTM A105 ASTM A105 AISI SAE 9840 page 2 Supply pressure Supply medium : 10.5 bar g maximum : air, nitrogen or sweet gas Ambient temperature : -30° C to +100° C Special versions for service outside this range on request Output torques : up to 3500 Nm RPD Pneumatic Actuator output torques Output torques in Nm Supply pressure (bar g) Model RP 15 D1 RP 15 D2 RP 30 D1 RP 30 D2 RP 60 D1 RP 60 D2 RP 120 D1 RP 120 D2 2 2.5 46 65 84 157 193 329 387 709 60 84 108 200 245 418 492 898 3 73 102 131 243 298 507 596 1086 3.5 86 120 155 286 351 596 700 1275 4 99 139 179 329 404 684 805 1463 5 126 175 226 415 510 862 1014 1841 6 152 212 273 501 616 1040 1224 2218 7 8 9 10 10.5 179 249 320 587 722 1218 1433 2595 205 286 368 674 827 1396 1642 2972 232 322 415 760 933 1573 1851 3349 259 359 462 846 1039 1751 2060 - 272 378 486 889 1092 1840 2165 - Note Max allowable pressure of 10.5 bar g is the static pressure applicable to fully stroked actuator against the travel stops Output torques in Nm Supply pressure (bar g) Model RP 120 D3 1.5 2 2.5 3 3.5 4 4.5 1073 1456 1839 2223 2606 2989 3372 Note Max allowable pressure of 5 bar g is the static pressure applicable to fully stroked actuator against the travel stops Tyco reserves the right to change the contents without notice page 3 RPD Pneumatic Actuator material specification Item Name 1 2 3 4 5 6 7 8 10 13 14 15 17 18 19 20 21 22 23 24 25 26 27 28 30 31 Housing Pinion Piston End flange Rack Shaft Cylinder gasket Shoulder washer Nut Cylinder tube Tie rod Thrust bearing screw Sealing washer Sealing washer Sliding block Piston guide sliding ring Retainer ring Screw O - ring O - ring Nut Nut Washer Washer Travel stop screw Screw Material Equivalent to US standards Nodular cast iron Nodular cast iron Carbon steel Carbon steel Nodular cast iron Alloy steel (nickel plated) Nitrile rubber Nylon Carbon steel Carbon steel (nickel plated) Alloy steel Carbon steel PVC PVC Bronze Teflon+Graphite Spring steel Alloy steel Nitrile rubber Nitrile rubber Carbon steel Carbon steel Carbon steel Carbon steel Carbon steel Alloy steel ASTM A536 gr 65-45-12 ASTM A536 gr 65-45-12 ASTM A105 ASTM A105 ASTM A536 gr 65-45-12 AISI SAE 9840 Qty 1 1 1 1 1 1 2 2 ASTM A194 gr 2 2 API 5LX gr X52 1 AISI SAE 9840 4 AISI SAE 1040 1 2 1 ASTM B427 Alloy UNS No. C90800 1 1 ASTM A479 type 302 2 ASTM A320 L7 1 2 1 ASTM A194 gr 2 8 ASTM A194 gr 2 1 AISI SAE 1040 1 AISI SAE 1040 2 AISI SAE 1040 2 ASTM A320 L7 1 • • • • • • • • Recommended spare parts Tyco reserves the right to change the contents without notice page 4 RPD - MSJ Pneumatic Actuator material specification: Actuator with Jackscrew Manual Override Item Name 1 2 3 4 5 6 7 8 10 13 14 15 17 18 19 20 21 22 23 24 25 26 27 28 31 33 34 35 37 38 39 Housing Pinion Piston End flange Rack Shaft Cylinder gasket Shoulder washer Nut Cylinder tube Tie rod Thrust bearing screw Sealing washer Sealing washer Sliding block Piston guide sliding ring Retainer ring Screw O - ring O - ring Nut Nut Washer Washer Screw Travel stop screw Manual override jackscrew O - ring Handwheel Washer Screw Material Equivalent to US standards Nodular cast iron Nodular cast iron Carbon steel Carbon steel Nodular cast iron Alloy steel (nickel plated) Nitrile rubber Nylon Carbon steel Carbon steel (nickel plated) Alloy steel Carbon steel PVC PVC Bronze Teflon + Graphite Spring steel Alloy steel Nitrile rubber Nitrile rubber Carbon steel Carbon steel Carbon steel Carbon steel Alloy steel Bronze Nitrited alloy steel + Bronze Nitrile rubber Carbon steel Stainless steel Stainless steel ASTM A536 gr 65-45-12 ASTM A536 gr 65-45-12 ASTM A105 ASTM A105 ASTM A536 gr 65-45-12 AISI SAE 9840 ASTM A194 gr 2 API 5LX gr X52 AISI SAE 9840 AISI SAE 1040 ASTM B427 Alloy UNS ASTM A479 type 302 ASTM A320 L7 ASTM A194 gr 2 ASTM A194 gr 2 AISI SAE 1040 AISI SAE 1040 ASTM A320 L7 ASTM B427 Alloy UNS AISI SAE 9840 + ASTM B427 Alloy UNS ASTM A283 gr D ASTM A479 type 304 ASTM A193 B8 Qty 1 1 1 1 1 1 2 2 2 1 4 1 2 1 No. C90800 1 1 2 1 2 1 8 1 1 2 1 No. C90800 2 2 No. C90800 2 2 2 2 • • • • • • • • • Recommended spare parts Tyco reserves the right to change the contents without notice page 5 RP D1 and RP D2 Pneumatic Actuators J H C overall dimensions W A E F V U G B D T S ø X Pneumatic connections Dimensions in mm Air Consumpt. Model A B RP RP RP RP RP RP RP RP 440 440 531 531 640 640 770 770 160 160 215 215 255 255 308 308 15 D1 15 D2 30 D1 30 D2 60 D1 60 D2 120 D1 120 D1 C 120 120 154 154 200 200 260 260 (litres) Weight D E F G H J S T U V W NPT Open Close (Kg) 175 175 206 206 250 250 310 310 265 265 325 325 390 390 460 460 41 41 54 54 66 66 82 82 55 55 70 70 85 85 100 100 140 140 164 164 204 204 270 270 80 80 100 100 120 120 160 160 224 224 274 274 329 329 390 390 74 74 93 93 112 112 135 135 5 5 7 7 15 15 28 28 22 22 36 36 40 40 50 50 50 50 65 65 85 85 100 100 1/4 1/4 1/4 1/4 1/2 1/2 1/2 1/2 0.8 0.9 1.2 2 2.5 4 4.5 8 Note - Dimensions and weights given are without optional bracket - For mounting flange details see separate coupling dimensions leaflet - W = maximum allowable mounting bracket dimensions (pneumatic cylinder side) Tyco reserves the right to change the contents without notice page 6 øX 1.7 1.8 3 4 6 8 10 15 12 13 21 25 38 44 77 85 RP 120 D3 Pneumatic Actuator øC J H overall dimensions W A G E U F B D T S ø X Pneumatic connections Dimensions in mm Air Consumpt. øX (litres) Weight Model A B øC D E F G H J S T U W NPT Open Close (Kg) RP 120 D3 815 308 400 310 505 82 100 270 160 449 156 100 100 1/2 16 23 150 Note - Dimensions and weight given are without optional bracket - For mounting flange details see separate coupling dimensions leaflet - W = maximum allowable mounting bracket dimension (pneumatic cylinder side) Tyco reserves the right to change the contents without notice page 7 RPS Pneumatic Actuator Spring return pneumatic actuator for 90° operation for On-Off and Modulating heavy duty service General The RPS pneumatic spring return actuator series was engineered and is manufactured to provide fail safe operation for any quarter turn application such as ball, plug, butterfly valves or dampers, in both On-Off and Modulating heavy-duty service. Simplicity, reliability and economy are at the top of the list of design parameters. The spring module incorporates one or two springs in series, depending on the model, and is fully encapsulated. This ensures safety to personnel and ease of assembly. Features - Totally enclosed, weatherproof housing in nodular cast iron for maximum strength and suitable for use in hostile environments - The mounting flange is identical on both faces of the housing, the shaft output drives have the same dimensions but are positioned at 90°. This allows the actuator to be used as spring to close or spring to open without modifications - A compact rack and pinion design provides simple construction - External travel stops for precise angular stroke adjustment between 80° and 100° - Electroless nickel plated and polished cylinder and output shaft for corrosion resistance and minimal friction - Floating type piston seals for low hysteresis and high sensitivity, preventing sticking problems - Jackscrew manual override - An extensive range of accessories is available: - limit switch boxes - explosionproof, intrinsically safe and/or weatherproof - limit switches can be provided in different types according to customer requirements - position transmitters - explosionproof, intrinsically safe and/or weatherproof - air conditioners - solenoid valves - explosionproof, intrinsically safe and/or weatherproof - control valves, flow regulators, quick exhaust valves - positioners - pneumatic or electropneumatic - pressure switches - pneumatic or electric - terminals enclosures, pushbutton panels - explosionproof or intrinsically safe and/or weatherproof - Special coatings for offshore or corrosive environments Tyco reserves the right to change the contents without notice page 8 RPS Pneumatic Actuator spring return for 90° operation 14 13 17 11 18 4 8 2 1 9 10 15 16 10 9 12 20 19 16 3 6 7 5 Materials of construction Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Name Material Equivalence to U.S. standards Housing Shaft Rack Pinion Sliding block Thrust bearing screw Sealing washer Shaft seal ring Travel stop screw Sealing washer Cylinder tube Piston Piston guide sliding ring Piston seal ring End flange Cylinder gasket Tie rod Spring retainer disk Spring Rack spacer rod Nodular cast iron Alloy steel (Nickel plated) Nodular cast iron Nodular cast iron Bronze Carbon steel PVC Nitrile rubber Carbon steel PVC Carbon steel (Nickel plated) Carbon steel Teflon + Graphite Nitrile rubber Carbon steel Nitrile rubber Alloy steel Carbon steel Carbon steel Carbon steel ASTM A536 gr 65 - 45 AISI SAE 9840 ASTM A536 gr 65 - 45 ASTM A536 gr 65 - 45 ASTM B427 Alloy UNS AISI SAE 1040 - 12 - 12 - 12 No C90800 AISI SAE 1040 API 5LX gr X52 ASTM A105 ASTM A105 AISI SAE 9840 ASTM A283 gr D ASTM A29 gr 9254 AISI SAE 1040 Technical data Supply pressure Supply medium : 10.5 bar g maximum : air, nitrogen or sweet gas Ambient temperature : -30° C to + 100° C Special versions for service outside this range on request Output torques : up to 940 Nm Tyco reserves the right to change the contents without notice page 9 RPS Pneumatic Actuator output torques Output torques in Nm Spring Supply pressure (bar g) torque 3 3.5 4 5 Model SST SET AST AET AST AET AST AET RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP 51 89 117 51 89 117 156 241 290 156 241 290 317 482 588 317 482 588 706 949 1240 706 949 1240 32 51 66 42 70 91 99 127 156 127 184 223 209 268 318 263 374 452 420 531 643 563 740 940 62 41 80 59 99 77 77 36 51 41 70 59 88 57 77 36 125 62 169 105 212 180 148 55 94 62 137 105 180 117 148 55 261 142 350 230 439 374 319 138 201 142 290 230 379 256 319 138 597 281 786 663 470 201 974 852 659 390 439 281 628 432 470 201 816 621 659 390 15S2A1 15S2B1 15S2C1 15S2A2 15S2B2 15S2C2 30S2A1 30S2B1 30S2C1 30S2A2 30S2B2 30S2C2 60S2A1 60S2B1 60S2C1 60S2A2 60S2B2 60S2C2 120S2A1 120S2B1 120S2C1 120S2A2 120S2B2 120S2C2 AST 6 AET AST 7 AET AST 8 9 10 10.5 AET AST AET AST AET AST AET AST AET 135 114 172 151 209 188 114 72 151 109 188 146 98 42 135 79 171 116 125 114 161 151 198 188 93 72 130 109 167 146 70 42 107 79 143 116 298 234 384 320 470 406 266 141 352 227 439 313 234 87 320 173 406 259 266 234 352 320 439 406 204 141 290 227 376 313 160 87 246 173 332 259 617 497 794 675 972 853 552 316 730 494 908 671 497 198 675 376 853 554 557 497 735 675 912 853 434 316 612 494 790 671 348 198 526 376 704 554 1352 1036 1730 1410 2110 1790 1229 767 1610 1150 1980 1520 1106 449 1480 826 1860 1200 1194 1036 1570 1410 1950 1790 998 767 1380 1150 1750 1520 777 449 1160 826 1530 1200 245 224 208 235 203 180 556 525 492 525 462 418 1150 1090 1030 1090 968 881 2480 2360 2240 2330 2130 1910 224 183 152 224 183 152 493 399 345 493 399 345 1030 849 732 1030 849 732 2170 1900 1580 2170 1900 1580 282 261 245 272 240 217 642 611 579 611 548 505 1330 1260 1210 1270 1150 1060 2860 2740 2620 2700 2510 2290 261 219 189 261 219 189 579 485 431 579 485 431 1210 1030 910 1210 1030 910 2550 2280 1960 2550 2280 1960 319 298 282 308 277 254 729 697 665 697 634 591 1510 1440 1390 1450 1320 1240 3240 3120 2990 3080 2890 2660 298 256 226 298 256 226 665 571 517 665 571 517 1390 1210 1090 1390 1210 1090 2920 2650 2340 2920 2650 2340 337 316 300 327 295 272 772 740 708 740 678 634 1600 1530 1480 1540 1410 1330 3430 3310 3180 3270 3070 2850 316 274 244 316 274 244 708 614 560 708 614 560 1480 1290 1180 1480 1290 1180 3110 2840 2520 3110 2840 2520 Note - Max allowable pressure 10.5 bar g (static pressure applicable to fully stroked actuator against the travel stop) - SET: Spring Ending Torque SST: Spring Starting Torque AST: Air Starting Torque AET: Air Ending Torque Output torques in Nm Spring Supply pressure (bar g) torque 1.5 2 2.5 3 3.5 4 5 Model SST SET AST AET AST AET AST AET AST AET AST AET AST AET AST AET RP RP RP RP RP RP 690 933 1220 690 933 1220 405 515 627 548 725 925 584 268 967 845 652 383 426 268 809 614 652 383 1350 1230 1110 1190 997 776 1040 766 448 1040 766 448 1730 1610 1490 1580 1380 1160 1420 1150 831 1420 1150 831 2120 2000 1870 1960 1760 1540 1800 1530 1210 1800 1530 1210 2500 2380 2260 2340 2150 1930 2190 1920 1600 2190 1920 1600 3270 3150 3020 3110 2910 2690 2950 2680 2370 2950 2680 2370 120S3A1 120S3B1 120S3C1 120S3A2 120S3B2 120S3C2 Note - Max allowable pressure 5 bar g (static pressure applicable to fully stroked actuator against the travel stop) - SET: Spring Ending Torque SST: Spring Starting Torque AST: Air Starting Torque AET: Air Ending Torque Tyco reserves the right to change the contents without notice page 10 RPS Pneumatic Actuator material specification Item Name 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Housing Pinion Piston End flange Rack Shaft Cylinder gasket Shoulder washer Nut Spring retainer disk Rack spacer rod Cylinder tube Tie rod Thrust bearing screw Spring Sealing washer Sealing washer Sliding block Piston guide sliding ring Retainer ring Screw O - ring O - ring Nut Nut Washer Washer Spring pin Travel stop screw Screw Vent plug Spacer tube Material Equivalent to US standards Nodular cast iron Nodular cast iron Carbon steel Carbon steel Nodular cast iron Alloy steel (nickel plated) Nitrile rubber Nylon Carbon steel Carbon steel Carbon steel Carbon steel (nickel plated) Alloy steel Carbon steel Carbon steel PVC PVC Bronze Teflon+Graphite Spring steel Alloy steel Nitrile rubber Nitrile rubber Carbon steel Carbon steel Carbon steel Carbon steel Carbon steel Carbon steel Alloy steel Aluminium + Bronze + Steel Carbon steel ASTM A536 gr 65-45-12 ASTM A536 gr 65-45-12 ASTM A105 ASTM A105 ASTM A536 gr 65-45-12 AISI SAE 9840 Qty 1 1 1 1 1 1 2 2 ASTM A194 gr 2 2 ASTM A283 gr D 1 AISI SAE 1040 1 API 5LX gr X52 1 AISI SAE 9840 4 AISI SAE 1040 1 ASTM A29 gr 9254 1 2 1 ASTM B427 Alloy UNS No. C90800 1 1 ASTM A479 type 302 2 ASTM A320 L7 2 2 1 ASTM A194 gr 2 8 ASTM A194 gr 2 1 AISI SAE 1040 1 AISI SAE 1040 2 ASTM A29 gr 4047 4 AISI SAE 1040 2 ASTM A320 L7 1 1 API 5LX gr X52 1 • • • • • • • • • Recommended spare parts Tyco reserves the right to change the contents without notice page 11 RPS - MSJ Pneumatic Actuator material specification: Actuator with Jackscrew Manual Override Item Name 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 Housing Pinion Piston End flange Rack Shaft Cylinder gasket Shoulder washer Nut Spring retainer disk Rack spacer rod Cylinder tube Tie rod Thrust bearing screw Spring Sealing washer Sealing washer Sliding block Piston guide sliding ring Retainer ring Screw O - ring O - ring Nut Nut Washer Washer Spring pin Travel stop screw Screw Vent plug Spacer tube Manual override jackscrew O - ring Travel stop screw Handwheel Washer Screw Material Equivalent to US standards Nodular cast iron Nodular cast iron Carbon steel Carbon steel Nodular cast iron Alloy steel (nickel plated) Nitrile rubber Nylon Carbon steel Carbon steel Carbon steel Carbon steel (nickel plated) Alloy steel Carbon steel Carbon steel PVC PVC Bronze Teflon + Graphite Spring steel Alloy steel Nitrile rubber Nitrile rubber Carbon steel Carbon steel Carbon steel Carbon steel Carbon steel Carbon steel Alloy steel Aluminium + Bronze + Steel Carbon steel Nitrited alloy steel + Bronze Nitrile rubber Bronze Carbon steel Stainless steel Stainless steel ASTM A536 gr 65-45-12 ASTM A536 gr 65-45-12 ASTM A105 ASTM A105 ASTM A536 gr 65-45-12 AISI SAE 9840 Qty 1 1 1 1 1 1 2 2 ASTM A194 gr 2 2 ASTM A283 gr D 1 AISI SAE 1040 1 API 5LX gr X52 1 AISI SAE 9840 4 AISI SAE 1040 1 ASTM A29 gr 9254 1 2 1 ASTM B427 Alloy UNS No. C90800 1 1 ASTM A479 type 302 2 ASTM A320 L7 2 2 1 ASTM A194 gr 2 8 ASTM A194 gr 2 1 AISI SAE 1040 1 AISI SAE 1040 2 ASTM A29 gr 4047 4 AISI SAE 1040 1 ASTM A320 L7 1 1 API 5LX gr X52 1 AISI SAE 9840 + 1 ASTM B427 Alloy UNS No. C90800 1 ASTM B427 Alloy UNS No. C90800 1 ASTM A283 gr D 1 ASTM A479 type 304 1 ASTM A193 B8 1 • • • • • • • • Recommended spare parts Tyco reserves the right to change the contents without notice page 12 RPS Pneumatic Actuator C J H overall dimensions for models 15 to 120S2 W A E U G B D F Vent S ø X Pneumatic connection Dimensions in mm øX Model RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP 15S2A1 15S2B1 15S2C1 15S2A2 15S2B2 15S2C2 30S2A1 30S2B1 30S2C1 30S2A2 30S2B2 30S2C2 60S2A1 60S2B1 60S2C1 60S2A2 60S2B2 60S2C2 120S2A1 120S2B1 120S2C1 120S2A2 120S2B2 120S2C2 A 569 569 569 730 730 730 717 717 717 938 938 938 858 858 858 1111 1111 1111 1015 1015 1015 1300 1300 1300 B 160 160 160 160 160 160 215 215 215 215 215 215 255 255 255 255 255 255 308 308 308 308 308 308 C 120 120 120 120 120 120 154 154 154 154 154 154 200 200 200 200 200 200 260 260 260 260 260 260 D E F 175 175 175 175 175 175 206 206 206 206 206 206 250 250 250 250 250 250 310 310 310 310 310 310 394 394 394 555 555 555 511 511 511 732 732 732 608 608 608 861 861 861 705 705 705 990 990 990 41 41 41 41 41 41 54 54 54 54 54 54 66 66 66 66 66 66 82 82 82 82 82 82 G 55 55 55 55 55 55 70 70 70 70 70 70 85 85 85 85 85 85 100 100 100 100 100 100 Air Consumpt. H J S U W NPT (litres) 140 140 140 140 140 140 164 164 164 164 164 164 204 204 204 204 204 204 270 270 270 270 270 270 80 80 80 80 80 80 100 100 100 100 100 100 120 120 120 120 120 120 160 160 160 160 160 160 353 353 353 514 514 514 460 460 460 681 681 681 548 548 548 801 801 801 635 635 635 920 920 920 5 5 5 5 5 5 7 7 7 7 7 7 15 15 15 15 15 15 28 28 28 28 28 28 50 50 50 50 50 50 65 65 65 65 65 65 85 85 85 85 85 85 100 100 100 100 100 100 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 0.9 0.9 0.9 0.9 0.9 0.9 2 2 2 2 2 2 4 4 4 4 4 4 8 8 8 8 8 8 Weight (Kg) 18 18 18 25 25 25 36 36 36 51 51 51 65 65 65 86 86 86 127 127 127 174 174 174 Notes - Dimensions and weights given are without optional bracket - For mounting flange details see separate coupling dimensions leaflet - W = maximum allowable mounting bracket dimensions (pneumatic cylinder side) Tyco reserves the right to change the contents without notice page 13 RPS Pneumatic Actuator øC J H overall dimensions for models 120S3 W A E G B D U F Vent S ø X Pneumatic connection Dimensions in mm Model RP RP RP RP RP RP 120S3A1 120S3B1 120S3C1 120S3A2 120S3B2 120S3C2 øX Air Consumpt. Weight A B øC D E F G H J S U W NPT (litres) (Kg) 1013 1013 1013 1299 1299 1299 308 308 308 308 308 308 400 400 400 400 400 400 310 310 310 310 310 310 703 703 703 989 989 989 82 82 82 82 82 82 100 100 100 100 100 100 270 270 270 270 270 270 160 160 160 160 160 160 647 647 647 933 933 933 100 100 100 100 100 100 100 100 100 100 100 100 1/2 1/2 1/2 1/2 1/2 1/2 16 16 16 16 16 16 172 172 172 207 207 207 Notes - Dimensions and weights given are without optional bracket - For mounting flange details see separate coupling dimensions leaflet - W = maximum allowable mounting bracket dimensions (pneumatic cylinder side) Tyco reserves the right to change the contents without notice page 14 RPD/RPS Pneumatic Actuator sizing criteria Valve data required Break to open torque Required torque to move the valve away from its closed position under the full differential pressure. This torque value must take into account the possible sticking effect which could affect the valve if it is closed for a long time. Reseating torque Required torque to close the valve under the full differential pressure. Break to close torque Required torque to move the valve away from its open position with maximum working pressure in the pipeline. This torque value can be high in the case of “double block and bleed” ball valves. End to open torque Required torque to fully open the valve. Running torque Required torque to actuate the valve in opening and in closing without differential pressure along the angular stroke except the fully open and fully closed positions where the required torques are those listed above. Dynamic torque Required torque to actuate the valve in opening under the medium flow through the valve. This torque value is high particularly on modulating service and when the medium speed and specific gravity are high. The angular position where the dynamic torque occurs has to be defined. Safety factor It is essential to confirm if the above torque values include a safety factor. Depending on the valve application additional safety factors may have to be considered over and above those recommended. Maximum allowable stem torque Maximum torque the valve stem can withstand. Valve stem dimensions Operating conditions data required • • • • Supply medium pressure range (minimum, normal, maximum) Type of actuator: double acting or spring return to close or spring return to open On-Off or Modulating service Frequency of operation and required operating times Actuator sizing general criteria A safety factor must be included during sizing if not included in the figures supplied by the valve manufacturer. The safety factor value has to be defined as a function of the valve type and size, of the working condition and of the operating time. The safety factor is usually included in the range from 1.2 to 1.5: higher values have to be employed in case of extreme working conditions (for instance in case of low temperature, dirty and/or high viscosity medium, very infrequent operation, modulating service, short operating time). The output torques values listed in the performance tables of actuators do not include a safety factor but are the minimum guaranteed torques. Tyco reserves the right to change the contents without notice page 15 RPD/RPS Pneumatic Actuator sizing criteria RPD actuators, because of the rack and pinion mechanism, have a “constant” output torque with a fixed supply pressure. For actuator sizing the following comparisons between the valve data, including the safety factors, and the actuator data have to be performed. • Check that the actuator output torque, with minimum supply pressure, exceeds all the valve required torques • During operation the actuator provides, along its full travel, only a torque equal to the required valve torque. No problems will occur if the actuator output torque, as listed in the performance table, exceeds the valve maximum allowable stem torque. But if there is the possibility that the valve stops along its stroke, due to abnormal conditions, it is necessary to check that the actuator output torque, with the maximum supply pressure or with the regulated pressure, if a pressure regulator is fitted on the pneumatic supply, does not exceed the valve maximum allowable stem torque and the actuator max operating torque Torque Sizing of RPD double acting actuators 0° Closed 45° Angular position 90° Open Sizing of RPS single acting actuators RPS single acting spring return actuators can be used as spring to close or spring to open. Sizing of RPS spring to close actuators Spring operation Torque For actuator sizing the following comparisons between the valve data, including the safety factors, and the actuator data have to be performed. • Check that the “spring ending torque” of the actuator exceeds the valve “reseating torque” with maximum differential pressure • Check that the “air starting torque” of the actuator, with minimum supply pressure, exceeds the valve “break to open torque” with maximum differential pressure • Check that the “spring starting torque” of the actuator exceeds the valve “break to close torque” with maximum working pressure in the pipeline • Check that the “air ending torque” of the actuator, with minimum supply pressure, exceeds the valve “end to open torque” • Where a valve “dynamic torque” is present, check that it is overridden by the actuator “air intermediate torque” with minimum supply pressure. “Air intermediate torque” is calculated by the formula: AIT = (AST + AET)/2. For a more accurate sizing BIFFI should be consulted • When required, since there is the possibility that the valve stops along its angular stroke because of abnormal conditions, it is necessary to check that the actuator “spring starting torque” and the “air starting torque”, with maximum supply pressure or with the regulated pressure, do not exceed the valve maximum allowable stem torque and the actuator maximum operating torque AST = Air Starting Torque AET = Air Ending Torque SST = Spring Starting Torque SET = Spring Ending Torque RPS (spring to close) AIR STROKE AST SET SPRING STROKE 0° Closed 45° Angular position SST AET 90° Open Sizing of RPS spring to open actuators For actuator sizing the following comparisons between the valve data, including safety factors, and the actuator data have to be performed. • Check that the “air ending torque” of the actuator, with minimum supply pressure, exceeds the valve “reseating torque”, with maximum differential pressure • Check that the “spring starting torque” of the actuator exceeds the valve “break to open torque” with maximum differential pressure • Check that the “air starting torque” of the actuator, with minimum supply pressure, exceeds the valve “break to close torque” with maximum working pressure in the pipeline • Check that the “spring ending torque” of the actuator exceeds the valve “end to open torque” • Where a valve “dynamic torque” is present, check that it is overridden by the actuator “spring intermediate torque”, which is calculated by the formula: SIT = (SST + SET)/2. For a more accurate sizing BIFFI should be consulted • When required, since there is the possibility that the valve stops along its angular stroke, because of abnormal conditions, it is necessary to check that the actuator “spring starting torque” and the “air starting torque”, with maximum supply pressure or with the regulated pressure, do not exceed the valve maximum allowable stem torque and the actuator maximum operating torque AST = Air Starting Torque AET = Air Ending Torque SST = Spring Starting Torque SET = Spring Ending Torque RPS (spring to open) Torque Spring operation SST SPRING STROKE AST AET AIR STROKE SET 0° Closed Tyco reserves the right to change the contents without notice 45° Angular position 90° Open page 16 RPD/RPS Pneumatic Actuator control system General BIFFI has the ability to apply advanced engineering technology to design and manufacture of pneumatic controls and accessories. The experience and knowledge acquired in the actuator industry allow BIFFI to meet with the highest requirements for control modes and operating conditions by correct selection of schematics, components, materials and protection treatment. The actuator service can be On-Off or Modulating. Actuator control can be local or remote by electric or pneumatic signals. The control system can include devices for automatic operation or stay put in case of emergency (electric or pneumatic supply failure, high temperature, low or high pipeline pressure etc.). For heavy duty service or special working conditions (for example low working temperature, sour gas supply, special emergency operation, etc.), control valves specially designed and manufactured by BIFFI can be supplied. Control systems can either be mounted on a panel or enclosed inside a weatherproof cabinet. Control systems can either be supplied separately or assembled on the actuator. The actuator housing has dedicated threaded holes for the mounting of control systems and accessories. Main components of the control system - Stop valves, check valves - Air conditioners (filter, pressure regulator with pressure gauge, lubricator) - Air storage tanks with accessories (relief valve, pressure gauge with stop valve, drain plug). Standard air tanks are designed, manufactured and tested according to ISPESL Standard. If required the tank can be supplied in accordance with different codes like ASME Vlll DIV. 1, SNCT/France, BS/UK, TÜV/Germany, etc. - Solenoid valves, manual valves, pneumatic pilot valves - Flow regulators - Quick exhaust valves - Pressure switches - pneumatic or electric - Terminal enclosures - Positioners - pneumatic or electropneumatic - I/P converters Features • The standard components have the body in aluminium. Brass and stainless steel versions can be supplied • The standard directional control valves are spool type. Poppet type valves are available • The standard solenoid valves are air pilot operated. Direct solenoid operated valves are available • Manual override for solenoid valves is available • Manual reset is available for solenoid valves and for pneumatic pilot valves • The electrical component enclosures can have explosionproof and/or weatherproof protection. The explosionproof enclosures are in accordance with CENELEC Standards EN 50014 and EN 50018. Enclosures in accordance with UL or CSA Standards can be supplied. Components suitable for use in intrinsically safe circuits are available • Terminals enclosures with increased safety protection are available • The pneumatic connections are in copper pipe and brass fittings as standard; stainless steel can be supplied on request • Standard weatherproof cabinets for control systems are in carbon steel. Glass reinforced polyester and the stainless steel on request Tyco reserves the right to change the contents without notice page 17 Control System for Pneumatic Actuators typical control systems for double acting actuators On-Off service: four way control valve 1 manual control 2 solenoid control pressurised air atmospheric pressure air pneumatic pilot control The diagram shows the simplest On-Off control. The gas supply pressure is applied to one side of the cylinder and exhausted from the opposite side. When the control valve (2) is actuated the connections of supply and exhaust to the cylinder chambers are reversed. The control valve can have many types of actuating devices (solenoid, manual control, pneumatic pilot, spring, etc.). The spring return control valves allow "fail safe" operation. dual solenoid control On-Off service: air fail safe system 1 This system allows "fail safe" operation when the pressure in the gas supply line drops below a set value. The diagram shows the actuator (1 ) in the "fail safe" condition. When the gas supply pressure drops below the pressure switch (5) set point, the pneumatic supply to the solenoid valve (6) pilot is exhausted and the actuator moves to the "failsafe" position by using the gas stored in the tank (4). The tank is connected to the gas supply through the check valve (3). 6 5 4 3 pressurised air pressurised air (low pressure) atmospheric pressure air 2 1 2 Modulating service electropneumatic positioner 4 3 5 pneumatic positioner P P pneumatic control signal electric control signal pressurised air (supply) reduced pressure air (opening chamber) reduced pressure air (closing chamber) Tyco reserves the right to change the contents without notice page 18 When modulating control is required as a function of a pneumatic or electric control signal, a positioner (5) is used, which controls the supply to the actuator cylinder to keep the valve in the required angular position. The positioner has a mechanical linkage to the actuator, for a feedback of the valve position. Control System for Pneumatic Actuators typical control systems for spring return actuators On-Off service: three way control valve The diagram shows the simplest On-Off control. The control valve (2) has two positions. In one position the gas supply pressure is connected to the cylinder chamber, and the actuator performs the "pneumatic" operation. In the other position the cylinder is connected to the exhaust and the actuator moves under the operation of the spring. The control valve can have many types of actuating devices (solenoid, manual control, pneumatic pilot, spring, etc.). Spring return control valves allow "fail safe" operation. 1 manual control 2 solenoid control pneumatic pilot control pressurised air atmospheric pressure air On-Off service: quick spring operation 1 When fast action is required under spring operation, a quick exhaust valve (3) is installed in the cylinder port to exhaust the gas from the cylinder directly to the atmosphere. When the control valve (2) opens to the atmosphere a differential pressure is created across the quick exhaust valve (3) causing it to open. The resultant high flow capacity from cylinder to atmosphere allows quick spring operation of the actuator. 3 2 pressurised air atmospheric pressure air Modulating service When modulating control is required as a function of a pneumatic or electric control signal, a positioner (5) is used, which controls the supply to the actuator cylinder to keep the valve in the required angular position. The positioner has a mechanical linkage to the actuator, for a feedback of the valve position. 1 electropneumatic positioner 4 2 3 5 P pneumatic positioner pneumatic control signal P electric control signal pressurised air (supply) reduced pressure air Tyco reserves the right to change the contents without notice page 19 RPD/RPS Pneumatic Actuator pneumatic positioner assembly Overall dimensions Actuator with pneumatic positioner G B Y Signal or pressure gauge Y Signal or pressure gauge X Pneumatic supply Note C = = For the missing dimensions, please refer to the “Base Construction” leaflets RPD-BU-E and RPS-BU-E F E D A Dimensions in mm X Y Model A B C D E F G NPT NPT RP RP RP RP 203 210 223 233 123 121 131 146 90 95 95 95 50 57 70 80 18 18 18 18 34 34 34 34 96 94 104 119 1/4 1/4 1/4 1/4 1/8 1/8 1/8 1/8 15 30 60 120 Note Overall dimensions For the missing dimensions, please refer to the “Base Construction” leaflets RPD-BU-E and RPS-BU-E Actuator with pneumatic positioner and limitswitch box 3/4 NPT Threaded hole cable entry A D E E F C C Y Signal or pressure gauge Y Signal or pressure gauge 160 F C X Pneumatic supply O N l Dimensions in mm X Y Model A B C D E F G H I L M N O NPT NPT RP RP RP RP 194 194 194 194 219 219 219 225 210 210 210 210 97 97 97 97 102 102 102 108 85 85 85 91 114 114 114 114 114 114 114 120 141 141 141 147 410 410 410 410 110 110 110 165 34 34 34 34 18 18 18 18 1/4 1/4 1/4 1/4 15 30 60 120 Tyco reserves the right to change the contents without notice 1/8 1/8 1/8 1/8 page 20 RPD/RPS Pneumatic Actuator coupling dimensions View from Y View from X = øC No. 4 threaded holes = = = B ±0.2 = Flow line = B ±0.2 -0,1 E 0 -0,1 E 0 øC No. 4 threaded holes A ±0.2 = = A ±0.2 Y H J = G K = J D L = K = -0,5 øF 0 -0,2 øM0 X Dimensions in mm Model 15 30 60 120 A B øC D E øF G H K J L øM 49.5 72.1 88.4 99 49.5 72.1 88.4 99 M8 M10 M12 M16 10 12 15 23 16 22 28 37 21 29 37 49 23 25 34 45 66 92 112 132 30 32 42 55 3 3 3 3 140 164 204 270 40 50 60 75 Notes 1. Both actuator flanges can be used for either mounting on the valve or ancillary equipment (positioner, limit switch box, etc.) 2. The output shaft has equal ends but with flat surfaces at 90° 3. The flat surfaces of the output shaft are shown for actuator in closed position Tyco reserves the right to change the contents without notice page 21 RPD/RPS Pneumatic Actuator mounting holes for accessories B ±0.2 = = = B A ±0.2 = front side F G øE No. 4 threaded holes F D H top view M ±0.2 L = = A ±0.2 K back side øE No. 4 threaded holes (optional) Dimensions in mm Model 15 30 60 120 A 55 70 88 124 B C D øE F G H K L M 110 125 160 190 12.5 15 16 18 43 56 68 82 M8 M10 M12 M16 14 16 19 23 17 35 35 50 98 120 150 183 114 136 160 210 67 80 105 124 181 216 265 334 Notes For the assembly of accessories on the actuator top see “coupling dimensions” on the front page Tyco reserves the right to change the contents without notice page 22 RPD/RPS Pneumatic Actuators limit switch box assembly A D F G C E B 3/4 NPT threaded hole (cable entry) Note • The limit switch box is shown in its standard position on the actuator (cable entry on the actuator front). If required, the box can be rotated 90° by 90°. Dimensions in mm Model A B C D E F G RP 15 RP 30 RP 60 RP 120 194 194 194 194 200 203 213 225 210 210 210 210 97 97 97 97 83 85 95 108 66 68 78 91 114 114 114 114 Tyco reserves the right to change the contents without notice page 23 RPD/RPS Pneumatic Actuator coding mode Coding mode Code no. 2 Actuator model 015 030 060 120 121 = = = = = RP RP RP RP RP 15 30 60 120 120 D3 and RP 120 S3 Type 1 2 3 4 5 6 7 8 = = = = = = = = D1 D2 and D3 S2A1 and S3A1 S2B1 and S3B1 S2C1 and S3C1 S2A2 and S3A2 S2B2 and S3B2 S2C2 and S3C2 Seals 0 = Nitrile rubber 1 = Fluoro carbon rubber (Viton) 2 = Fluorosilicon rubber Version Standard version 01 = with front holes and without jackscrew override 04 = with front holes and with jackscrew override Special version 02 = with front and back holes and without jackscrew override 05 = with front and back holes and jackscrew override Tyco reserves the right to change the contents without notice page 24 2 0 X X X A B Y Y