- Siemens Industry Online Support
Transcription
- Siemens Industry Online Support
SIPLUS CMS4000 Industrial I/O-Node IFN AI-D (ANALOGINPUT-DISTANCE) 6AT8000-1BB00-2XA0 Operating Instructions (compact) Contact Information SIEMENS AG DF FA SE PCI SP-PRM Breslauer Str. 5 90766 FUERTH GERMANY Customer Support +49 (0) 911 895 7222 (0,14 €/min. from the German landline network, deviating mobile communications prices are possible) Internet www.siemens.com/siplus-cms IFN AI-D SIEMENS AG Digital Factory, Factory Automation P.O. Box 4848 90026 NUERNBERG GERMANY Scope of delivery Device IFN AI-D Operating Instructions (compact) Description The IFN AI-D could record up to six analog input signals. The maximum sample frequency is 192 kHz per channel. The nodes will be linked per bus system (IEEE1394), transfer rate up to 400 Mbps to a higher lever industrial PC. Installation The product is designed for the application on a DIN Rail or for mounting angles. Operating with vibration loading the device has to be mounted with mounting angle. To avoid overheating the minimum distances specified in the technical data must be adhered to. Protective equipment and a disconnection unit for the device must be provided. Wiring SHIELD: cross slot screwdriver size 2 Recommended tightening: approx. 3 Nm. Commissioning (hardware) 1. Connect the IFN with a 24 V power supply. After a short LEDtest, the IFNs green PWR LED starts to blink. 2. Connect the IFN with the PC via a communication cable. If the IFN is connected to the PC for the first time, Windows will request a driver installation. To install the driver, follow the instructions of the hardware assistant. The directory for the drive installation is SIPLUS CMS4000\Drivers\IEEE1394. 3. After Windows has installed a driver for the IFN, the IFN can be used with X-Tools. The yellow LNK LED of the IFN lights up and the hardware installation is complete when the IFN is connected to the PC, the driver is installed and X-Tools is started. Caution: In configurations with ION devices (ION PROFIBUS DP Spy T001, ION BINARYINPUT T001, RPN IEEE1394B) and IFN devices (IFN VIB-A, IFN AI, IFN AI-D) in a common communication line, please notice the directives in the operation instruction. Technical Data Communication (LNK0…LNK2) Number Connector type Protocol Data transfer rate Galvanic isolation 3 8-pin socket plug (M12) IEEE1394a / b 400 Mbps no Power Supply (PWR) Connector type Supply voltage DC Over voltage protection DC Supply current DC Reverse voltage protection Voltage low dump Power dissipation DC Electrical isolation 5-pin male connector (M12) 18 … 32 V max. 35 V < 0.2 A @ 24 V yes Not allowed max. 4.8 W no Analoge Channels (CH1…CH6) Number Connector type Input voltage DC Input current DC Over voltage protection DC DC-Input resistance AC-Input resistance Input frequency Coupling inputs Sampling rate Down sampling rate (parameterize with X-Tools) Resolution Accuracy Nonlinearity Galvanic isolation 6 5-pin female connectors (M12) ± 20 V ± 25 µA ± 60 V typ. 800 min. 3.2 @ 96kHz 0 … 96 kHz DC 192 kHz 4 / 8 / 16 / 24 / 48 / 64 / 96 kHz 16 Bit (15 + sign) ± 0.5 % ± 0.08 % yes Cross talk attenuation (CTA) Signal to noise ratio (SNR) Cable break detection Cable short detection Electrical isolation - 90 dB @ 1 kHz - 80 dB yes no yes SHIELD Connector type Cross section M4 screw with detent clip 2.5 mm Connection Cable Communication Signal input Power supply Tailor-made 8-pin cable (screened) Tailor-made 5-pin cable (screened) Tailor-made 5-pin cable (screened) Environmental Conditions Ambient temperature during operation Transport and storage temperature Degree of protection - 40 ... + 65 °C - 40 ... + 85 °C IP67 Constructive Layout Design Dimensions (H x W x D) in mm Mounting Minimum distance (front, top, bottom) in mm Weight Aluminum 210 x 86 x 87 (without mounting) 210 x 86 x 97 (DIN rail mounting) Standard: DIN rail DIN EN 60715TH35-15 Optional: mounting angle* 80, 25, 25 ca. 1230 g Certifications CE, EAC, KC, RCM ATEX, IECEx For use in industrial areas Zone 2, see special conditions in manual *Accessories please look at operating instructions (not in scope of delivery) SIPLUS CMS4000 IFN AI-D Operation Instructions compact, 11/2014, A5E32612781-AB, © SIEMENS AG 2014 2