- Siemens Industry Online Support

Transcription

- Siemens Industry Online Support
SIPLUS CMS4000
Industrial I/O-Node
IFN AI-D (ANALOGINPUT-DISTANCE)
6AT8000-1BB00-2XA0
Operating Instructions (compact)
Contact Information
SIEMENS AG
DF FA SE PCI SP-PRM
Breslauer Str. 5
90766 FUERTH
GERMANY
Customer Support
+49 (0) 911 895 7222
(0,14 €/min. from the German
landline network, deviating
mobile communications prices
are possible)
Internet
www.siemens.com/siplus-cms
IFN AI-D
SIEMENS AG
Digital Factory,
Factory Automation
P.O. Box 4848
90026 NUERNBERG
GERMANY
Scope of delivery
Device IFN AI-D
Operating Instructions (compact)
Description
The IFN AI-D could record up to six analog input signals. The
maximum sample frequency is 192 kHz per channel. The nodes will
be linked per bus system (IEEE1394), transfer rate up to 400 Mbps
to a higher lever industrial PC.
Installation
The product is designed for the application on a DIN Rail or for
mounting angles. Operating with vibration loading the device has to
be mounted with mounting angle. To avoid overheating the
minimum distances specified in the technical data must be adhered
to. Protective equipment and a disconnection unit for the device
must be provided.
Wiring
SHIELD: cross slot screwdriver size 2
Recommended tightening: approx. 3 Nm.
Commissioning (hardware)
1. Connect the IFN with a 24 V power supply. After a short LEDtest, the IFNs green PWR LED starts to blink.
2. Connect the IFN with the PC via a communication cable. If the
IFN is connected to the PC for the first time, Windows will
request a driver installation. To install the driver, follow the
instructions of the hardware assistant. The directory for the
drive installation is SIPLUS CMS4000\Drivers\IEEE1394.
3. After Windows has installed a driver for the IFN, the IFN can
be used with X-Tools. The yellow LNK LED of the IFN lights up
and the hardware installation is complete when the IFN is
connected to the PC, the driver is installed and X-Tools is
started.
Caution: In configurations with ION devices (ION PROFIBUS DP Spy T001, ION BINARYINPUT T001, RPN IEEE1394B) and IFN devices
(IFN VIB-A, IFN AI, IFN AI-D) in a common communication line, please notice the directives in the operation instruction.
Technical Data
Communication (LNK0…LNK2)
Number
Connector type
Protocol
Data transfer rate
Galvanic isolation
3
8-pin socket plug (M12)
IEEE1394a / b
400 Mbps
no
Power Supply (PWR)
Connector type
Supply voltage DC
Over voltage protection DC
Supply current DC
Reverse voltage protection
Voltage low dump
Power dissipation DC
Electrical isolation
5-pin male connector (M12)
18 … 32 V
max. 35 V
< 0.2 A @ 24 V
yes
Not allowed
max. 4.8 W
no
Analoge Channels (CH1…CH6)
Number
Connector type
Input voltage DC
Input current DC
Over voltage protection DC
DC-Input resistance
AC-Input resistance
Input frequency
Coupling inputs
Sampling rate
Down sampling rate
(parameterize with X-Tools)
Resolution
Accuracy
Nonlinearity
Galvanic isolation
6
5-pin female connectors (M12)
± 20 V
± 25 µA
± 60 V
typ. 800
min. 3.2
@ 96kHz
0 … 96 kHz
DC
192 kHz
4 / 8 / 16 / 24 / 48 / 64 / 96 kHz
16 Bit (15 + sign)
± 0.5 %
± 0.08 %
yes
Cross talk attenuation (CTA)
Signal to noise ratio (SNR)
Cable break detection
Cable short detection
Electrical isolation
- 90 dB @ 1 kHz
- 80 dB
yes
no
yes
SHIELD
Connector type
Cross section
M4 screw with detent clip
2.5 mm
Connection Cable
Communication
Signal input
Power supply
Tailor-made 8-pin cable (screened)
Tailor-made 5-pin cable (screened)
Tailor-made 5-pin cable (screened)
Environmental Conditions
Ambient temperature during
operation
Transport and storage
temperature
Degree of protection
- 40 ... + 65 °C
- 40 ... + 85 °C
IP67
Constructive Layout
Design
Dimensions (H x W x D) in
mm
Mounting
Minimum distance
(front, top, bottom) in mm
Weight
Aluminum
210 x 86 x 87 (without mounting)
210 x 86 x 97 (DIN rail mounting)
Standard: DIN rail
DIN EN 60715TH35-15
Optional: mounting angle*
80, 25, 25
ca. 1230 g
Certifications
CE, EAC, KC, RCM
ATEX, IECEx
For use in industrial areas
Zone 2, see special conditions in manual
*Accessories please look at operating instructions (not in scope of delivery)
SIPLUS CMS4000 IFN AI-D
Operation Instructions compact, 11/2014, A5E32612781-AB, © SIEMENS AG 2014
2