Product data High voltage generator DG 106
Transcription
Product data High voltage generator DG 106
Product data High voltage generator DG 106 Description: The DG 106 high voltage generator is the latest discharging generator in the KERSTEN neXt® family of products and may be used to supply all neXt® discharging components. It is the most compact but also most powerful high voltage generator in its class for electrostatic discharging. Due to its extremely small size it is ideal to use wherever space is limited. The DG 106 high voltage generator needs a 24 VDC supply and is thus independent of globally varying supply voltage standards. The 3-LED display informs the user of the operating status of the high voltage generator, of any faults on the connected discharging components and of necessary cleaning of the latter. The DG 106 high voltage generator has two protected high voltage sockets for plugging in KERSTEN neXt® discharging components, fast and with no need for tools. Other discharging components may be indirectly connected, using KERSTEN neXt® high voltage distributors. 9 9 9 9 Simplified handling – automatic restart after a short Even easier to operate – now also usable as a tabletop unit Integrated servicing and cleaning display Maximum power, yet still compact and even lighter, weighing < 450 g KERSTEN Elektrostatik GmbH Burkheimer Strasse 9, D-79111 Freiburg +49 761 47944 0 [email protected] Version: 07/2012 www.kersten.de Technical changes reserved. Page 1 of 4 Product data Technical data: Supply voltage Unom VDC 24 ± 20 % I A 1.0 Max. operating current Ib A 0.63 Max. active power P W 15 Protection internally Control voltage Ust VDC 24 ± 20 % Voltage, fault output Uf VDC 24 ± 20 % Output voltage Ua kV DC +3.8 / -2.8 Max. output current Imax mA Protection rating IP 54 No. of high voltage plug connections 2 neXt® plug-in system Type of connection Ambient conditions - Transport and storage temperature - Operating temperature - Relative humidity (non-condensing) Dimensions * ** 0.9 T °C T °F -25 – +85* -13 – +185* T °C T °F +5 – +50** +41 – +122** RH % < 80 l, w, h mm 114, 84, 49 in acc. with UL 50 Type B / Class 3K3 max. +70 °C (+158 °F) in acc. with UL 50 Type B / Class 3K3 max. +40 °C (+104 °F) KERSTEN Elektrostatik GmbH Burkheimer Strasse 9, D-79111 Freiburg +49 761 47944 0 [email protected] Version: 07/2012 www.kersten.de Technical changes reserved. Page 2 of 4 Product data Connection cable pins: Use the supplied cable for electrical connections at the cylindrical plug on the front of the DG 106 high voltage generator. Please ensure correct polarity! The error message (ERR) need not be read, but it is recommended in order to monitor the operating status. Never connect 24 V to the SDA/SCL connections! 1 brown 2 white 3 blue 4 black 5 grey Blue: 0 V (PE) Brown: +24 V DC Black: ERR (error) White: SCL (clock) Grey: SDA (data) LED display: Green: Red: Yellow: High voltage (ON / OFF) Error Component cleaning required KERSTEN Elektrostatik GmbH Burkheimer Strasse 9, D-79111 Freiburg +49 761 47944 0 [email protected] Version: 07/2012 www.kersten.de Technical changes reserved. Page 3 of 4 Product data Technical drawing: All dimensions in mm. KERSTEN discharging components are EN 50178 (DC) and UL 508 certified. This means tested product safety compliant with European and North American standards. KERSTEN Elektrostatik GmbH Burkheimer Strasse 9, D-79111 Freiburg +49 761 47944 0 [email protected] Version: 07/2012 KERSTEN Elektrostatik GmbH is ISO 9001:2008 certified and audited by BUREAU VERITAS. www.kersten.de Technical changes reserved. Page 4 of 4