to supplimentary manual for 100W Coil
Transcription
to supplimentary manual for 100W Coil
AUBER INSTRUMENTS WWW.AUBERINS.COM Instruction Manual RDK-100/110/200/300 Supplementary Manual for 100W Coil Version 1.3 (April, 2015) 1. Introduction Table 2. Parameters in RDK-200 under access code “166”. The initial parameters in the RDK-100/110/200 controller are set for 250W coils. When a 100W Coil (Flat Coil, 20mm Coil, 15.8mm Coil w/ black Kevlar sleeve), rated as 100W under 120VAC, is used with these controller, some parameters should be adjusted to achieve good temperature control. 2. For RDK-100/110 Press SET key once, enter access code “0036”. Then press SET again. You will enter parameter settings. For 100W Coil, please set P value to 2.0. Other settings should remain unchanged. Please see Table 1. For 250W Coil, you should keep the P value to 5.0 (default value). Please refer the flow chart below for details. Description Proportional band (in 0.1 degree) Integral constant (second) Derivative constant (second) Output high limit Description Range Initial Knob Knob P p Proportional band (in 0.1 degree) 0-999 5.0 I I Integral constant (second) 0-999 40 lck 166 Knob d d Derivative constant (second) 0-999 10 souf SouF Damp Constant 0.1~1.0 0.4 ot ot Cycle Rate 2-199(sec) 2 p 125 filt FILT Digital Filter Strength 0-3 0 Knob End End Exit SET Enter Code XXXX 0036 SET SET Knob SET Integral Time Push down for 5s Turn clockwise/ counter-clockwise Push down Push down SET Derivative Time Knob SET XXXX d SET Damp Constant SET Push down d 10 SET XXXX i Push down oth 40 Knob Push down XXXX souf SET ot SET filt Proportional Constant XXXX p SET SET Initial 125 60 10 40% i 60 Parameter Display Operation Mode Range 0-999 0-999 0-999 0-100 233 450 Lck 0 Table 1. Parameters in RDK-100/110 under access code “0036”. Symbol Display Symbol Display p P I I d d OTH oth Cycle Rate SET XXXX Digital Filter Strength Figure 2. Flow chart of how to change the parameters under code 166. SET XXXX end Figure 1. Flow chart of how to change parameters under code 0036. 3. For RDK-200/300 Press and hold the knob down for 5s, then enter access code “166”, press knob once again to confirm. You will enter parameter setting mode. For 100W Coil, you need to set OTH value to 100%. Other settings should remain unchanged. Please see Table 2. For 250W Coil, you need to set OTH value to 40% (default value). Please refer the flow chart in Figure 2 for details. 2015.04 Auber Instruments Inc. 5755 North Point Parkway, Suite 99, Alpharetta, GA 30022 www.auberins.com E-mail: [email protected] Tel: 770-569-8420 P1/1