03 Measuring Alkalinity in Monoethylene
Transcription
03 Measuring Alkalinity in Monoethylene
Measuring Alkalinity in Monoethylene Glycol (MEG) Solutions Marion Seiersten ([email protected]) Arne Dugstad ([email protected]) Institute for Energy Technology PO Box 40 2027 Kjeller Abstract The paper reviews methods and practices for measuring alkalinity in aqueous solutions. The focus is on glycol systems where the alkalinity must be controlled in order to obtain corrosion protection and avoid scaling. Determining alkalinity by simple acid-base titration is difficult when the glycol contains acetate or other weak bases. More complex titration methods or combining titration with other analytical methods can solve the problem. Simplified methods that can be applied in field are under development. The basis for these is to convert all strong alkalinity to bicarbonate by equilibrating the solution with carbon dioxide. In one method the bicarbonate concentration is determined from the pressure build up when the liquid is acidified in a closed compartment. Another approach is to simultaneously measure the pressure and pH after pressurising the sample with carbon dioxide. Introduction Monoethylene glycol (MEG) is used as hydrate inhibitor in gas/condensate flowlines. Recycled MEG will contain ions of salts and neutral compounds picked up from formation water and injected chemicals. The concentration of these species depends on the source and how the MEG is recovered. Defining acceptance levels and to monitor if the MEG quality is within the limits are mandatory in order to avoid setups and down time. The alkalinity of the MEG is a key parameter and must be closely monitored. In most systems there will be alkalinity targets in order to: Maintain a low FeCO3 solubility in case corrosion is controlled by pH stabilisation Avoid scaling downstream the MEG injection point in case of formation water production Force precipitation of carbonate and hydroxide in the MEG recovery process The objective of this paper is to discuss analytical methods that can be used to control alkalinity. The main focus is on how to measure the concentration of bicarbonate, carbonate and hydroxide when formate, acetate and other carboxylate ions are present. The formal definition of alkalinity is “the number of moles of hydrogen ion equivalent to the excess of bases formed from weak acids with a dissociation constant K≤10-4.5 (at 25 °C and zero ionic strength)” [1]. The definition is not well suited for solutions that contain bases of carboxylic acids. For example, formate formed from formic acid having a dissociation constant K=10-3.7, will not be included while acetate will be included as the dissociation constant of acetic acid is K=10-4.7 [2]. The definition given by Oddo and Tomson which includes bases of carboxylic acids is better suited for oilfield applications [3]: Total Alkalinity = [OH − ] + [HCO3− ] + 2 ⋅ [CO32 − ] + [HS− ] + [OH − ] + [CHOO − ] + [CH 3COO − ] + ..... − [H + ] (1) Where [] denotes molar or molal concentration. Formate, acetate and other weak bases are included. A further differentiation of alkalinity is required as it is important to distinguish between the alkalinity that reacts with CO2 and gives a sufficiently high concentration of HCO3 and subsequent CO32- to precipitate carbonate solids, and the weak bases that hardly react with CO2. Consider the reaction between dissolved CO2 and a base, B-: CO 2 (aq) + B− (aq) + H 2 O(l) BH(aq) + HCO3− (aq) With the equilibrium constant, K: [BH] ⋅ [HCO3− ] =K [CO 2 ] ⋅ [B− ] (2) (3) - The K should be larger than 1-10 to give a sufficiently high concentration of HCO3 . The K consists of the dissociation constant of CO2, K1, and the dissociation constant of the acid BH, Ka: CO 2 (aq) + H 2 O(l) = HCO3− (aq) + H + (aq) BH(aq) = H + (aq) + B− (aq) K= - K1 Ka K= 1 [HCO3− ] ⋅ [H + ] [CO 2 ] [B− ] ⋅ [H + ] Ka = [BH] (4) (5) (6) In order to form HCO3 the dissociation constant of the conjugate acid of the base must be 1 to 1/10 of the CO2 dissociation constant; i.e. less than 10-7 (10-6.4-107.4 )which implies that acetate and the other carboxylate ions are too weak, while bases like MDEA (methyl diethanol amine with Ka(MDEAH+)=10-8.6) and MEA (methyl ethanol amine with Ka(MEAH+)=10-9.5) are sufficiently strong. Based on this, the alkalinity in oilfield waters and recycled MEG can be divided into strong alkalinity; 2 - the alkalinity that reacts with CO2 and gives an appreciable HCO3 concentration, and the weak alkalinity constituted by carboxylates and equally weak bases. The aqueous phase in a multiphase flowline will be in thermodynamic equilibrium with the gas and condensate phases. The CO2 in the gas will then assure that the strong alkalinity is converted to HCO3 . If the gas contains H2S there may also be appreciable amounts of HS-. The HCO3 (and HS-) will be maintained through the separation process and constitute the main part of the strong alkalinity in rich MEG. - When the MEG is heated and re-concentrated CO2 is boiled off and HCO3 reacts to CO32- and even CO32- may react to OH- according to: 2HCO3− (aq) CO 2 (g) + CO32 − (aq) CO32 − (aq) + H 2 O(l) CO 2 (g) + 2OH − (aq) (7) The strong alkalinity in the lean MEG will thus normally be CO32-, OH- and HS-. Strong bases like MDEA are also regained. If the MEG is not reclaimed, the alkalinity balance between rich and lean MEG will only change if some of the bases are volatile or if organic acids evaporate. The ionic bases will be removed by reclamation while volatile bases can be reclaimed. The methods for determining the alkalinity must be adapted to the type of alkalinity and some information is needed on the type of bases that may form in the system. When monitoring a rich MEG pre-treatment with forced precipitation of carbonates and hydroxide it is important to determine the OH- / HCO3 / CO32- speciation while it is only necessary to determine the strong alkalinity in order to monitor pH stabilisation. In some cases it can be sufficient to monitor the pH, but it should be noted that a pH measurement alone is seldom an accurate measure of alkalinity. pH depends not only on the alkalinity, but also on type of alkalinity and on the concentration of other solutes (dissolved species) as illustrated in Figure 1. In rich MEG the pH is a function of alkalinity, the weak/strong alkalinity distribution and the concentration of dissolved CO2 and H2S. In lean MEG it is a function of the OH-/CO32- distribution in an amine free system. In a system with amine, OH- and CO32- may still affect the pH if there are other sources of alkalinity than the amine. 3 Speciation OH-+CO32- CO3 2- + HCO3 HCO3 - -+ CO2 12 50 Lean MEG 40 Rich MEG Rich MEG pre-treatment 30 11 CO32OH- CO32- + HCO3- HCO3- + CO2 8 CO2 10 0 OH-+CO32- 10 9 HCO3- 20 pH vs. CO2 content 50 mM alkalinity 13 pH Concentration [mM] 60 7 0 10 20 30 40 50 CO2 content [mM] 60 6 70 0 10 20 30 40 50 CO2 content [mM] 60 70 Figure 1: Left: Alkalinity speciation as function of CO2 content (dissolved CO2 and including CO2 in HCO3 and CO32-) in a solution where OH-, CO32- and HCO3 constitute the alkalinity. The speciation in rich and lean MEG and in a rich MEG pretreatment is indicated. Right: The resulting pH. The calculation is for 80wt% MEG with 50 mM (10-3mol/L) alkalinity. Titration methods - The best way to determine alkalinity is acid titration. When OH-, CO32- and HCO3 constitute the alkalinity titration by HCl gives one or two equivalence points and the total alkalinity as well as the speciation of the three can be determines as outlined in an ASTM standard [4]. However, when determining the speciation one must be careful in order to avoid adding CO2 by the water used for dilution or otherwise. It becomes more difficult to recognise the end points and determine the speciation when the sample contains weaker bases. This is illustrated in Figure 2 which shows titration curves for solutions that contain OH-, CO32-, HCO3 and acetate. The left figure shows that the endpoint for HCO3 is visible when the solution is continuously sparged with N2 when the acetate to strong alkalinity ratio is 1. The right figure shows the effect of increasing acetate concentration on the titration curves. The end point for HCO3 is at pH 4.5 when there is no acetate. Increasing acetate concentration shifts it to higher pH and makes it less recognisable. In order to detect the end point for acetate and other carboxylates the titration must be continued to a pH between 2 and 2.5. The carboxylate end point can be difficult to detect, but it is also a deflection point and in most cases it can be determined from the d(pH)/dVtitrant curve. 4 100 mmol/kg acetate, 100 mmol/kg strong alkalinity N2 sparge 70 No gas 10 ERC N2 10 ERC pH 40 30 4 140 120 8 50 6 160 10 mmol/kg SA, 10 mmol/kg acetate 30 mmol/kg SA, 10 mmol/kg acetate 30 mmol/kg, no acetate 60 ERC No gas 8 pH Effect of acetate 12 80 100 6 80 60 4 40 20 2 0 2 10 0 0.5 1 1.5 2 2.5 ERC 12 0 0 20 0 0.5 1 1.5 2 2.5 0 Normalised volume Normalised volume Figure 2: Titration curve (pH versus acid volume normalised to strong alkalinity) for samples with different concentration of strong and weak bases. Left: Effect of N2 sparging to reveal HCO3 end point. Right: Effect of increasing acetate:strong alkalinity ratio on HCO3 end point. The strong alkalinity is 50/50 OH-/CO32- in all cases. - When the HCO3 end point is unrecognisable, the strong alkalinity can be determined from the total alkalinity when the concentration of carboxylic acids is known. The carboxylic acid concentration can be analysed independently by e.g. ion chromatography (IC), but it can also be determined by titration. Tomson et al. outlines a method where both the strong alkalinity and the carboxylate (anions of carboxylic acids) are determined by fitting a measured curve to a calculated curve [5]. It should be noted that the method is most accurate when the solution is sparged with CO2 to convert the strong alkalinity to HCO3 prior to the titration and the CO2 partial pressure is fixed during the titration. That is obtained by sparging the titration vessel with 1% CO2 in N2. Kaasa and Østvold describe a method where the carboxylic acid concentration is determined by titrating the solution with NaOH after the HCl titration [6]. This method requires that the CO2 formed when the sample is titrated with HCl is completely removed either by boiling or by vigorous sparging with N2 for sufficiently long time. The two titration methods mentioned are suitable for determining the strong alkalinity and the carboxylic acid concentration in formation water samples, in produced water and in rich MEG. Both can also be used for lean MEG when the OH- / CO32- / HCO3 speciation is not required, but only acid titration and back titration with NaOH is suitable when the speciation is required. When CO32- and/or OH- are present in addition to carboxylates, the acid titration curve will have at least two end points. The first is for CO32- + OH- and the last for the total alkalinity. This is exemplified in Figure 3. The figure shows the curves obtained by titration with acid (blue) and back titration with NaOH (green). The back titration curve is plotted as acid volume (total volume HCl minus volume NaOH). The volumes to the end points gives the total 5 alkalinity (A), the OH- + CO32- concentration (B), the acetic acid (acetate) concentration (C) and the strong alkalinity (D). S7 80 pH NaOH 10 B 8 pH 90 pH HCl D 6 ERC HCl 70 ERC NaOH 60 50 C 40 4 30 20 A 2 0 ERC 12 0 10 10 5 15 0 volume [ml] Figure 3: Titration curves of a lean MEG sample containing OH-, CO32- and acetate. The blue solid curve is the pH measured during acid titration (0.1N HCl), the blue dotted curve is a normalised derivative of the acid titration curve, the green curve is the pH measured during titration with NaOH (0.1 N) plotted as acid volume (Total volume HCl minus volume NaOH) and the green dotted curve is a normalised derivative of the NaOH titration curve. Bicarbonate and total inorganic carbon methods The titration methods described above requires a good titrator and they take time. When the solutions contain surfactants as is often the case for MEG, sparging can be a challenge due to the foaming. Alternative methods that are faster, but still give reliable results are thus demanded for field applications. The most popular of these methods determine the strong alkalinity based on the amount CO2 released when the solution is acidified. It should be noted that when such methods are applied on solutions where the strong alkalinity is constituted by bases other than HCO3 , these bases must be converted to HCO3 by sparging the solution with CO2. Necessary precautions must then be taken in order to remove the excess dissolved CO2 prior to the analyses and assure that the measured CO2 comes from HCO3 only. - A recent publication describes a simple method for determining HCO3 alkalinity and the basis for the acidifying methods [7]. The equipment is a sealable vessel that can be pressurised, a pressure gauge connected to it and means to inject acid and bicarbonate solution. The sample is added to the vessel and the vessel is closed and shaken. Then 6 an aliquot of acid is added before the vessel is shaken again. The procedure is repeated with an aliquot of NaHCO3. The pressure is read before the injection of acid, after injection of acid and thorough shaking and after the injection of NaHCO3. The HCO3 alkalinity can then be calculated based on the three pressure readings and a constant which incorporates the Henry’s law constant for CO2 and other constants for the apparatus and conditions. The beauty of the method is the first pressure reading which reduces the uncertainty due to dissolved CO2, and the final addition of HCO3 which calibrates for activity variation due to the sample composition. By doing this, the method eliminates the need for knowing or calculating activity/fugacity coefficients. Wang et al. show that the method is fairly accurate even for samples that contain considerable amounts of acetic acid as long as the pH of the original sample is above 5.8 [7]. The principle of acidifying and measure the released CO2 is also the basis for many commercial instruments which measure total inorganic carbon (TIC), process alkalinity etc. They can be used, but some precautions must be taken. They are often intended to measure CO32-, HCO3 and (for TIC also dissolved CO2) as a sum not the alkalinity which implies that if the strong alkalinity is more than HCO3 it must be converted to HCO3 . Furthermore one must assure that any excess dissolved CO2 which is not bounded as HCO3 , is removed prior to the measurement. These methods are readily applicable for rich MEG. If they are used for lean MEG, one must assure that all strong alkalinity is converted to HCO3 prior to the measurement. This can be done by sparging with CO2 prior to the measurements. The method cannot give the OH-/CO32- speciation which is needed in order to monitor precipitation of carbonates and hydroxides in a rich MEG pre-treatment or a MEG reclaimer. Methods based on pH measurements at fixed CO2 partial pressure In general the pH does not give the alkalinity. However, it is a good measure when the dissolved CO2 concentration is fixed by sparging with a gas with known CO2 content at a given pressure or by other means. Figure 4 illustrates this; the pH is a linear function of the logarithm of the strong alkalinity for a large range of alkalinity and CO2 partial pressures. However, the presence of carboxylates is not easy to overcome. As shown in Figure 5, the acetate buffers the pH when the acetate to strong alkalinity ratio is larger than ca. 1. The range of buffering depends slightly on the CO2 partial pressure. If it is calibrated for the acetate content, the method can be used as long as the strong alkalinity constitute more than 30% of the total alkalinity. 7 pH vs. CO2 partial pressure and alkalinity 9 0.1 bar CO2 pH 8 1 bar CO2 10 bar CO2 7 6 5 4 3 0.1 1 10 100 Strong alkalinity [mM] 1000 Figure 4: pH as function of strong alkalinity in 50wt% MEG. pH vs. alkalinity 9 100 mM acetate 50 mM Acetate 10 mM acetate 10 mM acetate, 0.3 bara CO2 0 acetate pH 8 7 6 5 4 1 10 100 Strong alkalinity [mM] 1000 Figure 5: pH as function of strong alkalinity in 50wt% MEG with varying acetate concentrations. The main calculations are for 3 bara CO2, one is for 0.3 bara CO2 as indicated in the legend. The method as outlined above is an alternative for determining the total strong alkalinity. It does not give any speciation. However, it is possible if one is also able to measure the amount of CO2 that dissolves in the liquid and reacts to HCO3 as described in a recent patent [8]. The method uses a vessel that can be pressurised, a pressure gauge, a pH meter and a device to add a controlled amount of CO2. An outline of the apparatus and a picture of a prototype are shown in Figure 6. The sample is added to the vessel and degassed before a known amount of CO2 is added from a cartridge or otherwise. The pH and pressure are read when the liquid and the gas are equilibrated, and the alkalinity is determined from an algorithm or from calibration curves. 8 P Constant volume of CO2 v1 v8 P-4 P-1 E-6 v5 v7 V-9 v4 Inert gas CO2 v2 sample v3 pH CO2 CO2 Pressurized sample measurement container v6 Figure 1 Figure 6: Outline (left) and picture of apparatus for measuring alkalinity based on CO2 partial pressure and pH. The advantage of adding a controlled amount of CO2 and measure the resulting CO2 pressure is that the alkalinity speciation can be determined. The CO2 that dissolves in the liquid will react to HCO3 if the part of the alkalinity is CO32- and/or OH- and based on the stoichiometry of the reactions (8), the speciation can be determined when the total strong alkalinity is derived from the pH measurement and the pH is measured both prior to and after the CO2 is added. The method requires that Henry’s law constant for CO2 is known at the given conditions. The pH alkalinity relationship is normally determined by calibration. The calibration can be simplified to addition of a constant amount of alkalinity. CO 2 (g) CO 2 (aq) CO 2 (aq) + CO32 − (aq) + H 2 O(l) 2HCO3− (aq) − (8) − 3 CO 2 (aq) + OH (aq) HCO (aq) This method is also suited for solutions where some of the alkalinity is HS- as it is a closed system. The limitations with organic acids are the same as for the sparging CO2 method; i.e. the strong alkalinity must constitute at least 30% of the total alkalinity. Conclusions The best methods for accurately determining the alkalinity of MEG solutions are titration. Precautions must be taken when organic acids are present in the sample. The titration method must be set-up so that the true end point can be read in order to determine the total alkalinity. To measure strong alkalinity, the concentration of carboxylate acids must be known from other analyses or be determined by a subsequent NaOH titration. Alternatively the strong alkalinity and the concentration of carboxylates can be determined by an algorithm that fits the dissociation constants to the measured curve. 9 There are alternatives to titration that is faster and easier to use in field. When using these one must take into account that most of them are developed for measuring the alkalinity as HCO3 . Other strong alkalinity must thus be converted to HCO3 by adding CO2. For methods designed to determine the inorganic carbon any dissolved CO2 must be removed prior to the measurements in order to obtain the correct HCO3 concentration. A novel method makes it possible to determine the alkalinity from combined measurements of pH and CO2 partial pressure. It has the advantage of being little affected by foaming and it is able to measure the CO32-/OH- speciation and can thus be used to monitor carbonate and hydroxide precipitation in a rich MEG pre-treatment or in a MEG reclaimer. References 1. 2. 3. 4. 5. 6. 7. 8. Dickson, A.G., An exact definition of total alkalinity and a procedure for the estimation of alkalinity and total inorganic carbon from titration data. DeepSea Res., Part A, 28(6A) (1981) p: 609-23. Partanen, J.I., Calculation of Stoichiometric Dissociation Constants of Formic, Acetic, Glycolic and Lactic Acids in Dilute Aqueous Potassium, Sodium or Lithium Chloride Solutions at 298.15 K. Acta Chemica Scandinavia, 52 (1998) p: 985-994. Oddo, J.E. and M.B. Tomson, Simplified Calculation of CaCO3 Saturation at High Temperatures and Pressures in Brine Solutions. Journal of Petroleum Technology, 34 (1982) p: 1583-1590. ASTM D3875-08 Standard Test Method for Alkalinity in Brackish Water, Seawater, and Brines. 2008, ASTM, Tomson, M.B., et al., Measurement of Total Alkalinity and Carboxylic Acid and Their Relation to Scaling and Corrosion. SPE Journal, (2006) p: 103110. Kaasa, B. and T. Østvold, Alkalinity in Oil Field Waters. What Alkalinity is and How it is Measured. SPE International Conference on Oilfield Chemistry. SPE-37277, 1997 Wang, L., et al., Field Method for Determination of Bicarbonate Alkalinity. SPE International Oilfield Scale Conference and Exhibition. SPE-169758-MS, 2014 Dugstad, A. and M. Seiersten, Method and Apparatus for Analyzing Alkalinity Conditions in Aqueous Liquids. W.I.P. Organisation, WO 2012/152935 A1, 2014. 10