Installation Instructions Model LVM
Transcription
Installation Instructions Model LVM
Installation Instructions Model LVM Live Voice Module INTRODUCTION The SIEMENS Model LVM Live Voice Module provides firefighters with a means of sending live voice messages to specified audio zones. The LVM has a push-to-talk switch on the microphone, as well as a retractable coiled cord. Both the push-to talk switch and the microphone are supervised. The LVM has a built-in speaker to preview active tones and messages. OPERATION Controls and Indicators The front panel of the LVM contains six switches and six pairs of LEDS. Each pair contains one bi-color (red/ green) and one yellow LED. The functions of the switches and LEDs are programmed using the Zeus Tool (Refer to the Zeus Quick Start Guide, P/N 315-033875). All LEDs can be programmed ON, OFF, or FLASHING. These switches are used for manual control of the voice system. Figure 1 LVM Live Voice Module The functions of the remaining LEDs and push buttons are defined as follows: PREANNOUNCE TONE (Yellow) When illuminated, indicates that the preannounce tone is active at the speakers. READY TO PAGE (Green) When illuminated, indicates that all selected zones are ready to be paged. MONITOR VOLUME P/N 315-034090-3 These two pushbuttons increase or decrease the volume of the speaker on the LVM. Siemens Building Tec hnologies echnologies Fire S afety Safety The back of the LVM contains 2 rotary address switches and five diagnostic LEDs, two plug-in cable connectors for the CAN and two plug-in cable connectors for audio. (See Figure 2). The function of the diagnostic LEDs are defined as follows: DESCRIPT ION OF LVM DIAGNOST ICS ERROR Factory use only. MIC FAIL LED glows steady when a failure of the microphone is detected. CAN FAIL LED glows steady when a failure on the CAN network is detected. CPU FAIL LED glows steady when a failure of the CPU is detected. POWER PRE-INSTALLATION LED glows steady when the power for the LVM is ON. Set the board address for the LVM using both of the ten-position rotary switches located on the back of the board (See Figure 2). Each of these addresses must be a sub-address of the DAC and must be the same as the addresses assigned in the Zeus Programming Tool. PLUG-IN CABLE AUDIO CONNECTION P5 P4 PLUG-IN CABLE CAN CONNECTION P3 P2 P7 3 1 P7 MUST BE INSTALLED ACROSS PINS 1 AND 2 ERROR MIC FAIL CAN FAIL CPU FAIL POWER S1 S2 456 23 456 78 9 01 9 01 78 23 ROTARY ADDRESS SWITCHES Figure 2 LVM Cable Connections, Diagnostics and Address Switches After setting the address, label each switch or LED. When viewed from the front panel of the LVM, the labels are on the left and the control switches and LEDs are on the right. • Refer to the Zeus configuration for the address of each module and its assigned functions. • Remove the label strip from its slot, and type or print a brief function identifier for each switch. • After completing the label strip, insert in back into its slot (See Figure 3). Figure 3 Inserting A Label Into The Back Of The LVM Siemens Building Technologies Fire Safety 2 P/N 315-034090-3 INSTALLATION The LVM mounts to the rear of the inner door in the CAB-1, CAB-2, CAB-3, REMBOX2 or REMBOX4 enclosures. Select the location of the LVM. In CAB-1/-2/-3 it can be mounted on either side of the PMI, over the two mounting studs in the desired location. In the REMBOX2/4 the LVM may mount in any of the positions (as viewed from the front). Secure the LVM to the inner door with the two nuts provided. (Refer to Figure 4.) When selecting the location to mount the LVM, keep in mind that no modules or power supplies/extenders can be installed in the space on the CAB-MP or REMBOX-MP directly behind the LVM. When using a REMBOX 2/4, the OCM-16 and SIM-16 cannot be used. INNER DOOR PMI LVM Figure 4 Mounting the LVM To The Rear Of The Inner Door CAN cable CCL, a 30 inch long 6 wire cable, P/N 599-634214, connects the LVM to the next CAN module or P3 on the CC-5/CC-2 or P4 on the RNI. A 24 inch long 10 wire audio cable, P/N 555-134260, connects the LVM to P4 on the CC-5/CC-2 or JP6 on the PMI or P1 on the RNI. (Refer to Figure 5.) Make sure that all cables seat fully into their connectors. Secure the cable in the back box using cable ties and the tie down points in the enclosure. The cable must have sufficient slack to allow the inner door to open fully without putting stress on the cable. Siemens Building Technologies Fire Safety 3 P/N 315-034090-3 WIRING Remove ELECTRICAL POWER prior to working on equipment. • Each LVM module is a node in the CAN bus. • Each LVM connects through the CC-5/CC-2 CAN bus via a plug-in cable to the DAC. • Up to 99 CAN modules, in any combination, can be connected to the CAN bus of each DAC. • Each LVM module is shipped with one CCL cable. • Cable connections for the LVM are shown in the following table and in Figure 5. LVM CABLE CONNECT IONS Part Number Cable Description Connection CCL CAN-CABLE-Long 30 in., 6-conductor 555-634214 Connects the LVM to the next CAN module or connects from P3 on CC-5/CC-2 to the LVM. Audio Cable AUDIO-CABLE 24 in., 10-conductor 555-134260 Connects LVM module to a CC-5/CC-2 or PMI. TO FMT TO CC-5/-2, PMI OR RNI* TO NEXT CAN MODULE P5 TO CC-5/-2 OR RNI* P4 P2 P3 P7 ERROR *SEE RNI INSTALLATION INSTRUCTIONS, P/N 315-033420 Figure 5 LVM Wiring The CAN bus requires a 120S resistance at each end of the loop. Refer to the DAC-NET Installation Instructions, P/N 315-035100 for details about CAN termination. ELECTRICAL RATINGS 24V Back Plane Current 0 Screw Terminal 24V Current 14mA max + 1mA per active LED 6.2V Back Plane Current 0 24V Standby Current 14mA max + 1mA per active LED For CE applications in Cerberus E100 systems refer to Installation Instruction A24205-A334-B844 (English) or A24205-A334-A844 (German). Siemens Building Technologies, Inc. 8 Fernwood Road Florham Park, New Jersey 07932 Siemens Building Technologies, Ltd. Siemens Gebäudesicherheit 2 Kenview Boulevard GmbH & Co. oHG Brampton, Ontario L6T 5E4 CN D-80930 München P/N 315-034090-3