here - GPI Millworks

Transcription

here - GPI Millworks
Dummy Lockset
070-107-B
070-108-B
070-109-B
070-112-B
INSTALLATION INSTRUCTIONS (Page 1 of 4)
LOCKSET CONTENTS
1. OUTSIDE PLATE
1
2
2. INSIDE PLATE
3
(x2)
4
(x2)
3. PLATE SCREWS (2)
4. LEVER HANDLE MOUNTING
SCREWS (2)
5. LEVER HANDLES (2)
5
REQUIRED TOOLS
1. PHILLIPS HEAD SCREWDRIVER
www.simplyelegantproducts.com/dummylocksets
1
1
Dummy Lockset
070-107-B
070-108-B
070-109-B
070-112-B
INSTALLATION INSTRUCTIONS (Page 2 of 4)
DUMMY LOCKSET MOUNTING INSTRUCTIONS FOR INACTIVE DOOR
INACTIVE VS.
ACTIVE DOOR
INACTIVE
ACTIVE
INACTIVE
ACTIVE
STEP 1
INACTIVE
The picture above illustrates the finished installation
DOOR
T-Astragal
STEP
1
of the fixed or dummy lockset to the inactive door. To
mount the fixed or dummy lockset to the inactive door, INACTIVE
1/2”
3”
DOORDIAMETER
drill two 1/2” diameter holes and one 1-1/2” diameter
T-Astragal
cut-out (1/2” deep) into the inactive door at a distance
of 3” from the outside edge on the narrow side of the
1-1/2”
T-Astragal of the inactive door, as shown at right.
DIAMETER
The hole heights should be equal to the hole heights1/2”
DIAMETER
on the active door lockset. The 1-1/2” cut-out should
have a centerpoint 3/4” from the bottom edge of the
top 1/2” hole. Note: Use the face plate as a template to
determine the hole locations.
1-1/2”
DIAMETER
(1/2” DEEP)
ACTIVE
DOOR
ACTIVE
2-1/2”
DOOR
DIAMETER
3”
(1/2” DEEP)
2-1/
DIAM
3/4”
Enlarged View
Note: The manufacturer is not responsible for replacing door units damaged by incorrect placement of drilled lockset holes.
www.simplyelegantproducts.com/dummylocksets
2
Dummy Lockset
070-107-B
070-108-B
070-109-B
070-112-B
INSTALLATION INSTRUCTIONS (Page 3 of 4)
LOCKSET MOUNTING INSTRUCTIONS (Continued)
STEP 2
STEP 2
NOTE:
The curved edge of the lever handle (#5)
should be facing up and pointing away
from the door opening.
STEP 3
DOOR OPENING
Insert the lever handles (#5) into the outside (#1) and
inside plates (#2). NOTE: When mounted, 1) each lever
handle (#5) should point away from the door opening,
and 2) the curve of each lever handle (#5) should be
facing upward.
STEP 3
Once each lever handle (#5) has been inserted properly
into the outside (#1) and inside plates (#2), secure them
to the plates with a screwdriver using the lever handle
mounting screws (#4) (two).
www.simplyelegantproducts.com/dummylocksets
3
Dummy Lockset
070-107-B
070-108-B
070-109-B
070-112-B
INSTALLATION INSTRUCTIONS (Page 4 of 4)
LOCKSET MOUNTING INSTRUCTIONS (Continued)
STEP 4
STEP 4
Attached outside (#1) and inside plates (#2) to the door
using the long plate screws (#3) (two). Note that the
inside plate (#2) has a screw hole and should be placed
on the inside of the door. Place plate screw (#3) through
screw holes and into hole drilled into the fixed door.
Place the blank outside plate (#1) on the outside of the
door, align and tighten plate screw (#3), as shown in
figures to right.
www.simplyelegantproducts.com/dummylocksets
4