ML6144 Direct Coupled Actuator
Transcription
ML6144 Direct Coupled Actuator
ML6144 Direct Coupled Actuator INSTALLATION INSTRUCTIONS DESCRIPTION CONDUIT CONNECTION The ML6144 Direct Coupled Actuator (DCA) is a 360 degree rotary actuator without end-stops. It mounts directly to a threaded shaft that drives a damper blade back and forth along the entire length of a Modular Integrated Terminal (MIT) air delivery box that is installed under the floor. 3-1/16 (77) 2-1/16 (53) 7/8 (22) 3-9/16 (91) 3-11/16 (93) SPECIFICATIONS FIXED-PLUG CONNECTION 3/8 (9) 1-13/16 (45) Models: ML6144A1007: Enclosure includes conduit connections. ML6144A1015: Standard enclosure (fixed-plug connections). 5-1/8 (130) Dimensions: See Fig. 1. 3-1/4 (83) Stroke: 360° cw or ccw. Electrical Ratings: Supply Voltage: 24 Vac ±20%, 50/60 Hz, Class 2 wiring. Connection: Four-pin Molex® connector. Nominal Power Consumption (at 24 Vac): 4.8 VA. Temperature Ratings: Operating: 40°F to 115°F (6°C to 46°C). Shipping: -40°F to 150°F (-40°C to 65°C). Humidity Rating: 5 to 95 percent RH (non-condensing). Noise: 35 dBA (maximum) at 1m. Torque Ratings (Breakaway and Stall): Minimum: 3.0 lb-in. Maximum: 6.0 lb-in. Timing: At 60 Hz M17373 Fig. 1. ML6144 Dimensions in in. (mm). Accessories: 32002031-002 Shaft Adapter (“clothespin” only). 32003303-001 Actuator to Actuator Cable, 25 ft. 32003303-002 Thermostat to Actuator Cable, 50 ft. 32003303-005 Actuator to Actuator Extension Cable, 25 ft. 32003303-006 Splitter Cable to parallel two strings of actuators, 12 in. Approvals: Underwriter Laboratories, Inc. Listed: Meets UL873 plenum requirements. Canadian Underwriter Laboratories, Inc. Listed. NEMA1 rated. Meets CE requirements. Weight: 2.5 lb. Load 1-3/4 (45) At 50 Hz None 10 rpm ±10% 8.3 rpm ±10% 3.0 lb-in. 9.5 rpm ±10% 7.9 rpm ±10% Actuator Shaft Mounting: 3/8 in. Acme threaded shaft coupled to actuator using included shaft adapter (“clothespin”) and roll pin (not included). Actuator Life Ratings (at 3.0 lb-in. Continuous Load): Full Revolutions: 3,200,000. Repositions: 1,500,000. ® U.S. Registered Trademark Copyright © 2001 Honeywell • All Rights Reserved INSTALLATION Mounting The actuator mounts on a 3/8 in. threaded shaft that drives a damper blade back and forth along the entire length of an MIT box: 1. Align actuator guides with horizontal runners on box, see Fig. 2. NOTE: Ensure actuator is oriented as shown in Fig. 2. 63-2545-2 ML6144 DIRECT COUPLED ACTUATOR 2. 3. 4. Slide the actuator into the MIT box until it comes in contact with the cross beam, see Fig. 2. Slide the shaft adapter onto the threaded damper shaft and secure using a roll pin (not supplied). (See Fig. 3.) Attach the adapter to the actuator by sliding it into the square hole in the hub until the circular shoulder is flush with the actuator hub and the adapter snaps into place. 2 1 M21011 Fig. 3. Mounting the shaft adapter (“clothespin”). 2 SERIES 60 CONTROLLER CCW CW L2 1 L1 (HOT) 1 2 3 4 1= GROUND 2= CW 3= CCW 4= COMMON 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 A MAXIMUM OF EIGHT ML6144 ACTUATORS CAN BE WIRED IN A SINGLE DAISY CHAIN. M16044A Fig. 4. ML6144 wiring. CHECKOUT AND TROUBLESHOOTING M17017 Fig. 2. Mounting the ML6144. Wiring The ML6144 wiring design facilitates trouble-free installation. Circuitry of both ML6144 Molex connectors is identical. So, either connector can serve as the input: 1. Connect the input (a Molex plug wired with Series 60 spdt wiring) to one ML6144 connector, see Fig. 4. 2. Use the second Molex connector, as needed, as output to another ML6144 to daisy-chain up to eight motors, see Fig. 4. Home and Building Control Home and Building Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 63-2545—2 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 B.B. Rev. 10-01 To check out the ML6144: 1. Operate the device through one full cycle. 2. Drive the damper fully closed. 3. Drive the damper fully open. 4. If the actuator does not run: a. Ensure the actuator is mounted properly. b. Check power supply for the presence of 24 Vac. c. Check for binding. 5. If the mounting is correct, 24 Vac input is present, the drive shaft is clear from obstruction, but the actuator does not run, replace it. Molex® is a registered trademark of Molex Inc. By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys’ fees, arising out of, or resulting from, any modification to the literature by you. www.honeywell.com