Pryco! - Davidson Sales Co.
Transcription
Pryco! - Davidson Sales Co.
Welcome to Pryco! Pryco’s “front” offices in Mechanicsburg, Illinois Since 1980, PRYCO, INC. has been a leading supplier of Standby Power fuel systems throughout the world. certainly has contributed to Pryco's strong position as the leader of the manufacture of diesel fuel systems in the World. Over the years we have pioneered and upgraded the fuel systems by listening to our customer needs. We enjoy the secure feeling of defining and implementing the cutting edge of engineered tank design that is imitated by the rest. We have earned the reputation of being versatile enough to work with our customers to fulfill the requirements of their complex, nonstandard projects. Our company policy is to continue to expand and develop new products. We are very proud of the personnel of our Research and Development Department. They are continually concentrating on improved methods of manufacture and the development of additional components used in standby fuel systems. Pryco's facilities are equipped with modern equipment capable of high production and quality control Our policy and manufacturing methods demand quality and accuracy. This most A network of sales firm represent Pryco across the United States. We also have international exporting representation. For professional assistance, we encourage you to call the sales rep firm in your area. They are listed on pages four and five of this section. Catalog Number — 0011.0 (Frc. 2012) The Content Herein Is Subject To Change Without Notice. Phone - 217 / 364-4467 Fax - 217 / 364-4494 P.O. Box 108, Mechanicsburg, IL 62545 -1- TABLE OF CONTENT SECTION 1 - DAY TANKS STANDARD DAY TANKS ...................................................................................... DT-1 MANUAL DAY TANKS .......................................................................................... DT-3 TRIM DAY TANKS ................................................................................................ DT-5 RUPTURE BASINS ............................................................................................... DT-7 CHART DRAWINGS Standard Day Tanks ..................................................................................DT-9 Manual Day Tanks .....................................................................................DT-15 Trim Day Tanks ..........................................................................................DT-21 Rupture Basins ................................................?....................................... DT-25 SECTION 2 - SUB-BASE TANKS DESCRIPTION, U/L LISTING & GEN-SET MOUNTING ...................................... SB-1 SUB-BASE TANK OPTIONS ................................................................................. SB-2 SAMPLE DRAWING OF DOUBLE WALL SUB-BASE TANK ................................ SB-3 CONSTRUCTION CHARACTERISTICS ............................................................... SB-4 CONDUIT STUB-UP AREA, PUMPING CAPABILITIES & HOW TO ORDER ....... SB-5 SECTION 3 - TRAILERS - SUB-BASE TANKS DESCRIPTION ...................................................................................................... TR-1 TRAILER OPTIONS .............................................................................................. TR-2 SECTION 4 - PUMP SETS DESCRIPTION,STANDARD FEATURES, OPTIONS, ENCLOSURES ................ PS-1 SUGGESTED PUMP SET OPTIONS .................................................................... PS-3 SECTION 5 - OPTIONS & ACCESSORIES RECOMMENDED OPTIONAL ACCESSORIES ..................................................... OP-2 INDEX BY OPTION CATEGORY ????????????????????... OP-3 ELECTRICAL OPTIONS ........................................................................................ OP-8 MECHANICAL OPTIONS ....................................................................................... OP-14 PUMPS—BRONZE ??????????????????????????... OP-25 PUMPS—CAST IRON ?????????????????????????.. OP-25 DUPLEX PUMPS & MOTORS and OTHER ITEMS ............................................ OP-26 HAND PUMPS ????????????................................................. OP-26 MOTORS ................................................................................................................ OP-27 FUEL CONTROL & MONITORING SYSTEM OPTIONS (FCM) ........................... OP-28 EVOLUTION PLC & OPTIONS .............................................................................. OP-30 BATTERY BOXES & FRAMES .............................................................................. OP-32 PARTS .................................................................................................................... OP-33 SECTION 6 - AUXILIARY EQUIPMENT REMOTE PUMPING UNIT ..................................................................................... AE-1 DUPLEX PUMPING SYSTEM ................................................................................ AE-5 CIRCUIT BREAKERS ............................................................................................ AE-6 ENCLOSED INDUSTRIAL CONTROL PANEL ...................................................... AE-7 REMOTE FILL PANEL ........................................................................................... AE-9 REMOTE FILL STATION ....................................................................................... AE-11 DRIP BASIN ............................................................................................................ AE-13 SPILL CONTAINER ............................................................................................... AE-15 FUEL OIL COOLER ................................................................................................ AE-17 BATTERY BOXES .................................................................................................. AE-21 BATTERY FRAMES ............................................................................................... AE-23 EMERGENCY VENTS ............................................................................................ AE-26 SECTION 7 - FUEL CONTROL & MONITORING SYSTEM (FCM) and EVOLUTION PLC SYSTEM Product Descriptions The Content Herein Is Subject To Change Without Notice. Phone - 217 / 364-4467 Fax - 217 / 364-4494 P.O. Box 108, Mechanicsburg, IL 62545 -2- SALES REPRESENTATIVES MAP REF SALES REP FIRM Advanced Fuel Systems 1 Kelly York 510 East 17th Street, #310 Idaho Falls, ID 83404 All New England Sales 2 3 & 8 Jon Dunn & Peter Dunn 410 Great Road, 3rd Floor P. O. Box 1443 Littleton, MA 01460-4443 Bruster and Associates Dave Bruster 2300 Corner Rock Road Midlothian, VA 23113-2284 Control Equipment & Sales 4 Bob Melton 212 Red Bay Dr. Maylene, AL 35114 Davidson Sales, Inc. 5 839 Bill France Boulevard Daytona Beach, FL 32117 PHONES & ONLINE Phone—208 / 360-2944 Fax—208 / 542-6262 Email—[email protected] Website—www.advfuelsys.com TERRITORIES Southern Idaho, Montana, Wyoming, Utah, and Northern Nevada Phone—800 / 466-8151 Cell—617 / 513-3274 Fax—978 / 486-9318 Email—[email protected] Website—www.allnesales.com Maine, Vermont, New Hampshire, Rhode Island, Connecticut, Massachusetts, and New York Phone—804 / 794-4136 Fax—804 / 794 3879 Email—[email protected] Website—www.brusterassociates.com Maryland, Virginia, District of Columbia, North Carolina, and South Carolina Phone—205 / 621-6850 Fax—205 / 621-6852 Alabama, Mississippi, and Tennessee Email—[email protected] Phone—386 / 274-2079 & 2179 Cell—386 / 871-2791 Fax—386 / 274-2279 Email—[email protected] Georgia, Florida, and Puerto Rico The Content Herein Is Subject To Change Without Notice. Phone - 217 / 364-4467 Fax - 217 / 364-4494 P.O. Box 108, Mechanicsburg, IL 62545 -3- SALES REPRESENTATIVES MAP REF SALES REP FIRM EPAC, Sales & Service Co. 6 Ken Jones 116-A W. Harwood Road, #A Hurst, TX 76054 H. Ertel, Inc 7 Harry Ertel 2700 Erie Street, Box 4640 Racine, WI 53402 Power Source Midwest 9 Mike DeMauro 18 Hawk Ridge Blvd., Suite 120 Lake St. Louis, MO 63367 S. F. Griggs & Associates 10 Steve Griggs 15301 N.E. 90th Street Redmond, WA 98052 Sobek Enterprises, Inc. 11 Bob Sobek P.O. Box 428 225 So. Emerson Ave, Suite 181 Greenwood, IN 46143 R. F. Partridge & Assoc. 12 Dick Partridge 13875 Cerritos Corp. Drive, #B Cerritos, CA 90703 R. N. K. International, Inc. Rohit Israni & Amin Shidi 30 Muller, Suite 213 Irvine, CA 92618 Pryco, Inc. 13 301 Garvey Street P. O. Box 108 Mechanicsburg, IL 62545 PHONES & ONLINE TERRITORIES Phone—817 / 485-9383 Fax—800 / 875-3720 E-Mail—[email protected] Web — www.epacsales.com Texas, and Oklahoma Phone—262 / 639-8763 Cell—262 / 909-4052 Fax—262 / 639-2820 E-Mail—[email protected] Wisconsin, Minnesota (Eastern Area), Iowa, Northern Illinois (North of I-80), and Michigan Phone—636 / 625-4771 & 4772 Cell—314 / 422-2578 Fax—636 / 625-4773 Email— [email protected] Missouri, Kansas, Nebraska, South Dakota, and Illinois (South Of I-80) Phone—425 / 869-5867 Fax—425 / 869-9797 Washington, Oregon, Alaska, and “Panhandle” of Idaho Email—[email protected] Phone—317 / 881-1580 Fax—317 / 881-2069 Email— [email protected] Phone—562 / 802-7345 Fax—562 / 802-3186 Email: [email protected] Phone—949 / 829-8690 Fax—949 / 829-8693 Phone—217 / 364-4467 Fax—217 / 364-4494 Email—[email protected] Web—www.Pryco.com Indiana, and Kentucky California, Nevada, and Arizona International All states shown in gray (not listed above for other Sales Reps), all U.S. Territories, and foreign countries. The Content Herein Is Subject To Change Without Notice. Phone - 217 / 364-4467 Fax - 217 / 364-4494 P.O. Box 108, Mechanicsburg, IL 62545 -4- TECHNICAL NOTES PUMP / MOTOR SIZING The flow rate and pressure determine the size of pump and motor. Select pump motor by horsepower rating & characteristics. 2 GPM PUMP - 1800 RPM MOTOR @ 60° F. 4 GPM PUMP - 1800 RPM MOTOR @ 60° F. PRESSURE (PSI) FLOW RATE (GPM) HP REQ. MOTOR HP PRESSURE (PSI) 40 1.86 .14 1/3* 60 1.74 .18 80 1.62 100 1.50 FLOW RATE (GPM) HP REQ. MOTOR HP 40 3.41 .22 1/3 1/3* 60 3.08 .29 1/3 .23 1/3* 80 3.23 .36 1/2 .28 1/3 100 3.03 .43 1/2 * Also ¼ HP DC Motors 10 GPM PUMP - 1800 RPM MOTOR @ 60° F. 8 GPM PUMP - 1800 RPM MOTOR @ 60° F. PRESSURE (PSI) FLOW RATE (GPM) HP REQ. 40 10.10 .90 1 3/4 60 9.90 1.20 1½ .95 1 80 9.60 1.50 1½ 1.15 1½ 100 9.40 1.75 2 FLOW RATE (GPM) HP REQ. 40 7.00 .55 3/4 60 6.50 .75 80 5.50 100 PRESSURE (PSI) MOTOR HP 23 GPM PUMP - 1800 RPM MOTOR @ 60° F. PRESSURE (PSI) FLOW RATE (GPM) HP REQ. 40 22.50 1.53 1½ 60 22.10 1.92 80 21.70 100 21.30 MOTOR HP 40 GPM PUMP - 1200 RPM MOTOR @ 60° F. MOTOR HP PRESSURE (PSI) FLOW RATE (GPM) HP REQ. MOTOR HP 40 36.00 1.70 2 2 60 34.00 2.30 5 2.25 5 80 32.00 2.80 5 2.70 5 100 30.00 3.50 5 The Content Herein Is Subject To Change Without Notice. Phone - 217 / 364-4467 Fax - 217 / 364-4494 P.O. Box 108, Mechanicsburg, IL 62545 -5- TECHNICAL NOTES TEMPERATURE INFLUENCES OF THE PROPERTIES OF #2 FUEL OIL TEMPERATURE (DEG. F.) DENSITY (LBS / FT3) WEIGHT (LBS / GAL) SPECIFIC GRAVITY VISCOSITY (cP) VISCOSITY (cS) 0 56.10 7.50 0.899 27.9 31.0 20 55.50 7.42 0.890 16.6 18.7 40 54.80 7.33 0.879 10.0 11.4 60 54.10 7.23 0.867 7.2 8.3 80 53.50 7.15 0.858 4.8 5.6 100 52.90 7.07 0.848 3.3 3.9 120 52.60 7.03 0.843 2.5 3.0 140 52.40 7.00 0.840 2.1 2.5 160 52.20 6.98 0.837 1.6 1.9 180 52.00 6.95 0.834 1.4 1.7 200 51.40 6.87 0.824 1.2 1.5 300 49.20 6.58 0.789 0.6 0.7 400 46.70 6.25 0.749 0.3 0.4 CONVERSION TABLE PRESSURE (PSI) TO FEET OF HEAD PSI FT. OF HEAD PSI FT. OF HEAD PSI FT. OF HEAD PSI FT. OF HEAD 1 2.31 10 23.10 19 43.90 60 138.60 2 4.62 11 25.40 20 46.20 65 150.10 3 6.93 12 27.70 25 57.70 70 161.70 4 9.24 13 30.00 30 69.30 75 173.20 5 11.60 14 32.30 35 80.80 80 184.80 6 13.90 15 34.60 40 92.40 85 198.30 7 16.20 16 37.00 45 103.90 90 207.90 8 18.50 17 39.30 50 115.50 95 219.40 9 20.80 18 41.60 55 127.00 100 230.90 The Content Herein Is Subject To Change Without Notice. Phone - 217 / 364-4467 Fax - 217 / 364-4494 P.O. Box 108, Mechanicsburg, IL 62545 -6- Terms & Conditions PRYCO, INC. P. O. Box 108 Mechanicsburg, IL 62545 THE FOLLOWING CONDITIONS SHALL GOVERN PURCHASE ORDERS BASED ON PRYCO INC, QUOTATIONS: Quotations are not binding upon Pryco Inc. (“Seller”) until accepted by an authorized employee of the Seller 1. ACCEPTANCE – The receipt of a purchase order from the party identified on a Pryco Inc. quotation as the buyer (the “Buyer”) for the goods described on said quotation (the “Goods”) shall be conclusively deemed an unconditional acceptance by the Buyer of this offer and all terms and conditions hereof notwithstanding and provisions of any purchase order or other document provided or offered by the Buyer to the contrary. Seller reserves the right to accept or reject all purchase orders received pursuant to this quotation. 2. AGENT’S AUTHORITY - Buyer agrees that no agent, employee or representative of Seller has authority to bind Seller to any affirmation, representation, or warranty concerning the Goods other than those warranties expressly set forth herein. 3. PRICES – Prices quoted are only for quantities of Goods specified on the quotation. Unless specifically noted, pricing is valid for thirty (30) days. Pryco Inc. reserves the right to adjust prices at any point in the future. The purchase price for Goods specified in the purchase order for less than the quantity on the quotation will be the Seller’s price for the next lower quantity. If the Buyer requests pre-production samples or that an order be filled in partial quantities, the Buyer agrees to pay additional charge, to be determined by the Seller. 4. SHIPMENT – Shipment shall be F.O.B. Seller’s plant. Seller reserves the right to designate routing and means on all shipments. Seller will attempt to honor, but does not guarantee, any shipping date requested by Buyer. All risk of loss shall pass to Buyer upon delivery of Goods to a carrier F.O.B. Seller’s plant. Orders may be filled by partial or complete shipments. Delay in delivery of any part of the Goods shall not relieve Buyer from its obligation to accept and pay for the remaining Goods. 5. PAYMENT – In the event payment is not made by the Buyer as provided herein, Buyer agrees to pay interest on the unpaid amount at the rate of the lesser of 2% per month, or the greatest rate allowed by law. Notwithstanding the forgoing, if, at any time, Seller, in good faith, determines that Buyer’s credit shall have become impaired, Seller may decline to make shipment hereunder, except in exchange for cash in advance. 6. WARRANTIES – Seller warrants the Goods will be as described on the face hereof, will be free from any defects in material and workmanship at the time of delivery and will be manufactured in accordance with the Fair Labor Standard Act of 1938, as amended. SELLER MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED. In order to assert a claim for breach of warranty, Buyer must contact Seller within one (1) year from date of sale determined by invoice date and which Seller’s examination shall disclose to its satisfaction to thus defective. This remedy is agreed by Buyer and Seller to constitute a sole and exclusive remedy and all sales are made subject to the conditions that Seller is not liable for consequential damage or for personal injuries of Buyer or its agents thereof. Seller will not warrant installation of Goods by Buyer or its agents. 7. EXCLUSIVE REMEDY – The exclusive remedy of the Buyer for any breach of the warranties set out in Section (7) will be, in Seller’s sole discretion, the replacement or repair of the Defective Goods without charge to Buyer, provided Buyer pays shipping charges for return of such Goods to Seller. 8. LIMITATION OF DAMAGE – In the event of a breach hereof, Seller will not under any circumstance be liable for consequential or incidental damage or expenses of the Buyer including without limitation lost profits, whether or not the Seller has been advised of the same. 9. BUYER’S INDEMNITY – The Buyer shall indemnify and hold Seller harmless from and against any and all losses, damages and expenses (including attorneys’ fees and other costs of defending any action) that the Seller may sustain or incur as a result of any claim of negligence, breach of implied warranty or strict liability by the Buyer, its successors, agents, assigns or customers, whether direct or indirect, in connection with the use of the Goods. 10. FORCE, MAJEURE; ALLOCATIONS – Failure of Seller to make or Buyer to take all or any shipment hereunder, if such failure is due to act of God, war, embargoes, and any other similar cause beyond the control of the party so failing, shall not subject such party to any liability to the other party, and in such event, at the request of either party the total quantity of products to be shipped due to such causes. Should Seller at any time be unable to supply its own and all of its customers requirements (including customers not under supply contract) of any product, Seller will allocate its available supply of products to its customers on such terms as it, in the exercise of its discretion, deems advisable, and in such event Seller will not be liable for failure to ship Buyer the full quantity of such products and the balance of the order not shipped will be cancelled, For purpose hereof, Seller’s customers shall be deemed to include the subsidiaries and affiliates of Seller. CONTINUED NEXT PAGE The Content Herein Is Subject To Change Without Notice. Phone - 217 / 364-4467 Fax - 217 / 364-4494 P.O. Box 108, Mechanicsburg, IL 62545 -7- Terms & Conditions CONTINUED FROM PRECEEDING PAGE 11. CANCELLATIONS – Orders for Goods may be cancelled by the Buyer only upon immediate payment by Buyer of all of the foregoing: (a) for all completed work, the individual unit price of the order, (b) for all partially completed work, the percentage of completion (as determined by Seller in its sole discretion) multiplied by the individual unit price of the order, and (c) for all raw material, packaging, components, and engineering work, the actual cost to Seller therefore, plus reasonable handling and general overhead charges as determined by the Seller. 12. STOP ORDERS – Buyer may put its purchase order on hold only if it provides to Seller a written stop work order, which shall be valid for only fourteen (14) days from receipt by Seller. No later than fourteen (14) days after the date of the stop work order, Buyer shall proceed with its purchase order or shall pay cancellation charges as noted in Section 11. If the Buyer fails to indicate its decision, it shall be deemed to have elected to pay cancellation charges. 13. INFRINGEMENT – In the event that Buyer has specified certain requirements for the Goods, the Buyer shall defend, indemnify and hold harmless against any and all claims, expenses (including reasonable attorneys’ fees), or losses suffered or incurred by Seller as a result of or arising out of a claim that any Goods infringe on any patent, trademark, service mark, copyright or other intellectual property right of any other person or entity. 14. PROPRIETARY INFORMATION – CONFIDENTIALITY – Buyer shall consider all information furnished by Seller to be confidential and shall not disclose any such information to any other person or entity. This obligation shall apply to viewings of Seller’s process and production facilities, drawings, specifications, or other documents prepared by Seller for Buyer. The prior two sentences shall not apply to any information that is generally publicly known at the time of disclosure to the Buyer, or that is subsequently publicly disclosed without any breach by any obligation or duty to the Seller. Unless otherwise agreed in writing, no commercial, financial or technical information disclosed in any manner or at any time by Buyer to Seller shall be deemed secret or confidential and Buyer shall have no rights against Seller with respect thereto except such rights as may exist under patent laws. 15. WAIVER – Waiver by either Seller or Buyer of a breach of any provision hereof shall not be deemed a waiver of any current or future noncompliance therewith and such provision shall remain in full force and effect. 16. SOLE AGREEMENT – This writing is intended by parties as a final and complete expression of their agreement with respect to the subject matter hereof, and shall supersede all prior understandings, writings, negotiations and agreement with respect thereto. The terms and conditions set out herein may be amended only by a writing specifically referencing that it is intended to modify this quotation and signed by duly authorized agent of the parties. The express terms hereof shall not be varied by any course of dealing, performance or usage of trade. Any different, conflicting or additional terms in any purchase order, document or the like provided or offered by the Buyer are hereby expressly rejected. 17. DISPUTES – Any dispute arising under this quotation which is not settled by agreement of the parties may, upon the election of Seller, be decided by arbitration pursuant to the rules of the American Arbitration Association. Pending any decision, appeal or judgment in such proceedings or the settlement of any dispute arising under this order. Buyer shall pay for all Goods delivered and Seller may elect to proceed or to stop performance hereunder. 18. WEBSITE DOCUMENTS – Seller Standard Terms and Conditions and any updates thereto are incorporated herein and are binding on Buyer, and Buyer acknowledges having access to such documents. If Buyer is unable to access the Sellers website, Buyer may notify Seller by phone at 217-364-4467 to obtain a copy from Seller. HOW TO CONTACT US: OFFICE HOURS — 8:00 a.m. TO 5:00 p.m., USA Central Time (( - 6 GMT) USPS MAIL FREIGHT and PARCEL DELIVERY PRYCO, INC, P. O. BOX 108 MECHANICSBURG, IL 62545 PRYCO, INC, 3rd & GARVEY STREETS MECHANICSBURG, IL 62545 PHONE — 1-217-364-4467 FAX — 1-217-364-4494 EMAIL — [email protected] The Content Herein Is Subject To Change Without Notice. Phone - 217 / 364-4467 Fax - 217 / 364-4494 P.O. Box 108, Mechanicsburg, IL 62545 -8- STANDARD DAY TANKS Pryco’s STANDARD Day Tanks are available in either a U/L Listed (Label #142) or a basic (non-U/L Listed) design. In addition to the standard features listed below U/L Listed tanks have additional internal reinforcement an emergency vent properly sized to the tank and a U/L Listed label (File #MH12807 - Aboveground Tank for Flammable Liquids). Pryco Tanks are fabricated of heavy gauge steel by certified welders and are tested accordingly. STANDARD FEATURES DOUBLE WALL TANKS Removable 6½" Square Inspection Plate w/ Gasket A totally enclosed outer shell may be added resulting in a double wall construction. Both the inner and the outer tanks are vented separately and each are pressure tested. Fuel Level Gauge Heavy Duty Float Switch “Press-to-Test” Switch When enclosing a U/L Listed day tank an additional emergency vent is added to the double wall containment area the same size as the inner tank. (The U/L Listing is “Secondary Containment Aboveground Tank for Flammable Liquids” File MH12807.) "Pump Running" Indicator Light 1/3 hp Thermally Protected 120vac 1ph 60hz Motor 2 gpm Bronze Gear Pump w/Stainless Steel Shafts Threaded Pipe Connections for: Engine Supply and Return (w/Drop Tubes) Atmospheric Vent Emergency Vent (If U/L Listed) Pump-To-Tank Inlets and Outlets (w/Drop Tubes) Overflow (Normally Back to Main Tank) Tank Drain (w/Drop Tube) Extra 2” Connection Ports (2 ports in top of 10 thru 150 gallon tanks [one will be used for option 301, if included]; 1 port in tank top of 200 gallons and above) - Standard design tanks only If Double Wall Secondary Containment Add: An Atmospheric Vent An Emergency Vent (If U/L Listed) All day tanks (10 gallon and more capacity) excluding Trim day tanks have all threaded connections located on the tank top (except the tank overflow and the double wall drain and vent). The inner tank drain is located on the tank top under the removable cover. TANK VENTING Each tank (and double wall containment area if applicable) has a 2” Atmospheric Vent. If the tank is U/L Listed an Emergency Vent is added. The size of the U/L Emergency Vent depends upon the wetted surface area of the tank. The wetted surface of the day tanks shown within this section has been calculated and the U/L vent size is shown below. If the tank is U/L Listed and double walled the same size Emergency Vent is also added to the double wall containment area. 2” - 10—50 Gallons Removable Top Cover 3” - 60—150 Gallons Epoxy Coating Inside 4” - 200—500 Gallons and Pryco (Medium) Gray Exterior Paint (or an Industrial Color of Choice) 6” - 600—1000 Gallons Catalog Number — 0011.0 (12/2012) The Content Herein Is Subject To Change Without Notice. P.O. Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 DT-1 STANDARD DAY TANK REFERENCE DATA STANDARD SINGLE WALL DAY TANKS TANK SIZE BASIC DESIGN (U.S. GAL) MODEL WT * (Lbs) U/L LISTED MODEL WT * (Lbs) SINGLE WALL DRAWING REF BASIC & U/L STANDARD DOUBLE WALL DAY TANKS BASIC DESIGN 150% 200% MODEL R/B ** R/B ** U/L LISTED WT * (Lbs) MODEL DOUBLE WALL DRAWING REF WT * (Lbs) BASIC 150% 200% & U/L R/B ** R/B ** SIZE CATEGORY “A” DAY TANKS 5 PY5 60 PY5UL 75 CALL CALL CALL PY5DW 160 PY5ULDW 175 CALL CALL CALL 10 PY10 85 PY10UL 100 DT-9 DT-25 DT-28 PY10DW 170 PY10ULDW 195 DT-12 DT-25 DT-28 15 PY15 95 PY15UL 110 DT-9 DT-25 DT-28 PY15DW 200 PY15ULDW 215 DT-12 DT-25 DT-28 25 PY25 105 PY25UL 120 DT-9 DT-25 DT-28 PY25DW 230 PY25ULDW 245 DT-12 DT-25 DT-28 SIZE CATEGORY “B” DAY TANKS 50 PY50 193 PY50UL 197 DT-10 DT-26 DT-29 PY50DW 367 PY50ULDW 371 DT-13 DT-26 DT-29 60 PY60 220 PY60UL 226 DT-10 DT-26 DT-29 PY60DW 420 PY60ULDW 428 DT-13 DT-26 DT-29 75 PY75 236 PY75UL 243 DT-10 DT-26 DT-29 PY75DW 454 PY75ULDW 461 DT-13 DT-26 DT-29 100 PY100 257 PY100UL 263 DT-10 DT-26 DT-29 PY100DW 502 PY100ULDW 509 DT-13 DT-26 DT-29 150 PY150 302 PY150UL 309 DT-10 DT-26 DT-29 PY150DW 604 PY150ULDW 611 DT-13 DT-26 DT-29 882 PY200ULDW 895 DT-14 DT-27 DT-30 SIZE CATEGORY “C” DAY TANKS 200 PY200 427 PY200UL 438 DT-11 DT-27 DT-30 PY200DW 275 PY275 495 PY275UL 505 DT-11 DT-27 DT-30 PY275DW 1111 PY275ULDW 1124 DT-14 DT-27 DT-30 300 PY300 500 PY300UL 510 DT-11 DT-27 DT-30 PY300DW 1124 PY300ULDW 1137 DT-14 DT-27 DT-30 400 PY400 572 PY400UL 583 DT-11 DT-27 DT-30 PY400DW 1285 PY400ULDW 1297 DT-14 DT-27 DT-30 500 PY500 613 PY500UL 624 DT-11 DT-27 DT-30 PY500DW 1396 PY500ULDW 1409 DT-14 DT-27 DT-30 600 PY600 653 PY600UL 663 DT-11 DT-27 DT-30 PY600DW 1489 PY600ULDW 1501 DT-14 DT-27 DT-30 700 PY700 700 PY700UL 710 DT-11 DT-27 DT-30 PY700DW 1622 PY700ULDW 1635 DT-14 DT-27 DT-30 800 PY800 743 PY800UL 753 DT-11 DT-27 DT-30 PY800DW 1897 PY800ULDW 1910 DT-14 DT-27 DT-30 900 PY900 786 PY900UL 809 DT-11 DT-27 DT-30 PY900DW 2025 PY900ULDW 2056 DT-14 DT-27 DT-30 1000 PY1000 818 PY1000UL 841 DT-11 DT-27 DT-30 PY1000DW 2110 PY1000ULDW 2141 DT-14 DT-27 DT-30 * WEIGHTS ARE APPRXIMATE DEPENDING UPON ATTACHED OPTIONS, ETC. **1R/B—RUTURE BASIN See Page DT-1 For U/L Listed Emergency Vent Sizing. The Content Herein Is Subject To Change Without Notice. P.O. Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 DT-2 MANUAL DAY TANKS Pryco MANUAL Day Tanks are identical to Standard Day Tanks but do not have a pump motor and a control system. This is to facilitate possible future conversion to a Standard pumping system by adding a few parts. (All Manual day tanks have a removable cover.) Like all of Pryco’s tanks Manual day tanks are available as either a basic non-U/L Listed configuration or a U/L Listed one (Label 142 File #MH12807 - Above-ground Tank for Flammable Liquids). Both include the Standard Features listed below. The U/L Listed tanks also include additional internal reinforcement an emergency vent properly sized to the tank and a U/L Listed label. Pryco Tanks are fabricated of heavy gauge steel by certified welders and are tested accordingly. STANDARD FEATURES—MANUAL TANKS Removable 6½" Square Inspection Plate w/ Gasket Fuel Level Gauge Threaded Pipe Connections for: Engine Supply and Return (w/Drop Tubes) Atmospheric Vent Emergency Vent (If U/L Listed) Pump-To-Tank Inlets and Outlets (w/Drop Tubes) Overflow (Normally Back to Main Tank) Tank Drain (w/Drop Tube) Extra 2” Connection Manual Tank Fill (2”) w/Lockable Fill Cap If Double Wall Secondary Containment Add: An Atmospheric Vent An Emergency Vent (If U/L Listed) Removable Top Cover Epoxy Coating Inside A 300-gallon U/L Listed Manual Double Wall Day Tank . USES OF MANUAL TANKS Manual Tanks take on a variety of roles other than that of a typical day tank. For example: Larger Manual tanks are often used as the system’s main storage tank. In this role they are normally used in conjunction with a day tank with pump and controls. (Consider a U/L Listed double walled version.) Smaller versions may be used as a wallmounted “dry sump” for automatic engine lubrication. The only restriction is like all tanks they should not be utilized as a pressurized vessel. SECONDARY CONTAINMENT DOUBLE WALL TANKS and RUPTURE BASINS All day tanks may be set within a Rupture Basin or Open Top Dike. Rupture basins are available with a minimum capacity of either 150% or 200% of the inner tank (the vessel where fuel is normally stored). The inner tank is used to determine rupture basin size. Single wall day tanks may be set within either a 150% or a 200% rupture basin whereas those with double wall construction will only fit within a 200% minimum capacity rupture basin. Weatherproof rupture basins are also available see Option 335 on page OP-20. Pryco (Medium) Gray Exterior Paint (or an Industrial Color of Choice) The Content Herein Is Subject To Change Without Notice. P.O. Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 DT-3 MANUAL DAY TANK REFERENCE DATA STANDARD SINGLE WALL DAY TANKS TAN SINGLE WALL K BASIC DESIGN U/L LISTED DRAWING REF SIZE (U.S. GAL) MODEL WT * (Lbs) MODEL WT * BASIC 150% 200% & (Lbs) U/L R/B ** R/B ** STANDARD DOUBLE WALL DAY TANKS BASIC DESIGN DOUBLE WALL DRAWING REF U/L LISTED MODEL WT * (Lbs) MODEL WT * BASIC 150% 200% & (Lbs) U/L R/B ** R/B ** SIZE CATEGORY “A” DAY TANKS 5 PY5M 69 PY5MUL 74 PY5MDW 140 PY5MULDW 144 CALL 10 PY10M 104 PY10MUL 108 DT-15 DT-25 DT-28 PY10MDW 195 PY10MULDW 200 DT-18 DT-25 DT-28 15 PY15M 125 PY15MUL 129 DT-15 DT-25 DT-28 PY15MDW 234 PY15MULDW 239 DT-18 DT-25 DT-28 25 PY25M 143 PY25MUL 147 DT-15 DT-25 DT-28 PY25MDW 267 PY25MULDW 271 DT-18 DT-25 DT-28 CALL CALL CALL CALL CALL SIZE CATEGORY “B” DAY TANKS 50 PY50M 178 PY50MUL 182 DT-16 DT-26 DT-29 PY50MDW 355 PY50MULDW 359 DT-19 DT-26 DT-29 60 PY60M 207 PY60MUL 213 DT-16 DT-26 DT-29 PY60MDW 411 PY60MULDW 418 DT-19 DT-26 DT-29 75 PY75M 225 PY75MUL 231 DT-16 DT-26 DT-29 PY75MDW 446 PY75MULDW 473 DT-19 DT-26 DT-29 100 PY100M 246 PY100MUL 252 DT-16 DT-26 DT-29 PY100MDW 494 PY100MULDW 501 DT-19 DT-26 DT-29 150 PY150M 291 PY150MUL 297 DT-16 DT-26 DT-29 PY150MDW 596 PY150MULDW 603 DT-19 DT-26 DT-29 DT-20 DT-27 DT-30 SIZE CATEGORY “C” DAY TANKS 200 PY200M 418 PY200MUL 428 DT-17 DT-27 DT-30 PY200MDW 876 PY200MULDW 888 275 PY275M 485 PY275MUL 495 DT-17 DT-27 DT-30 PY275MDW 1105 PY275MULDW 1117 DT-20 DT-27 DT-30 300 PY300M 490 PY300MUL 500 DT-17 DT-27 DT-30 PY300MDW 1118 PY300MULDW 1130 DT-20 DT-27 DT-30 400 PY400M 563 PY400MUL 573 DT-17 DT-27 DT-30 PY400MDW 1278 PY400MULDW 1291 DT-20 DT-27 DT-30 500 PY500M 604 PY500MUL 614 DT-17 DT-27 DT-30 PY500MDW 1390 PY500MULDW 1402 DT-20 DT-27 DT-30 600 PY600M 643 PY600MUL 653 DT-17 DT-27 DT-30 PY600MDW 1482 PY600MULDW 1495 DT-20 DT-27 DT-30 700 PY700M 691 PY700MUL 701 DT-17 DT-27 DT-30 PY700MDW 1616 PY700MULDW 1628 DT-20 DT-27 DT-30 800 PY800M 733 PY800MUL 743 DT-17 DT-27 DT-30 PY800MDW 1890 PY800MULDW 1903 DT-20 DT-27 DT-30 900 PY900M 777 PY900MUL 800 DT-17 DT-27 DT-30 PY900MDW 2019 PY900MULDW 2050 DT-20 DT-27 DT-30 1000 PY1000M 809 PY1000MUL 832 DT-17 DT-27 DT-30 PY1000MDW 2104 PY1000MULDW 2135 DT-20 DT-27 DT-30 * WEIGHTS ARE APPRXIMATE DEPENDING UPON ATTACHED OPTIONS, ETC. **1R/B—RUTURE BASIN See Page DT-1 For U/L Listed Emergency Vent Sizing. The Content Herein Is Subject To Change Without Notice. P.O. Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 DT-4 TRIM DAY TANKS Pryco TRIM Day Tanks have the same standard features (see below) as its Standard Day Tank counterpart but has a smaller footprint. Trim tanks come in either a U/L Listed (Label 142) or a basic non-U/L Listed version. The U/L Listed tanks have additional internal reinforcement an emergency vent properly sized to the tank and a U/L Listed label (Label 142 File #MH12807 - Aboveground Tank for Flammable STANDARD FEATURES Removable 6½" Square Inspection Plate w/Gasket Fuel Level Gauge Heavy Duty Float Switch “Press-to-Test” Switch "Pump Running" Indicator Light 1/3 hp Thermally Protected 120vac 1ph 60hz Motor 2 gpm Bronze Gear Pump w/Stainless Steel Shafts Shown above is a 100-Gallon Trim Day Tank (PY100T) with a Weatherproof U/L Listed Rupture Basin. Threaded Pipe Connections for: Four - 1" NPT Threaded Pipe Connections One - 2" NPT Threaded Pipe Connection for Tank Vent Tank Drain (Sized To Tank Capacity) If Double Wall Secondary Containment Add: An Atmospheric Vent An Emergency Vent (If U/L Listed) Removable Top Cover Epoxy Coating Inside Pryco Tanks are fabricated of heavy gauge steel by certified welders and are tested accordingly. Pryco (Medium) Gray Exterior Paint (or an Industrial Color of Choice) See page DT-1 regarding Tank Venting This is a 60-Gallon Trim Double Wall U/L Listed Day Tank (PY60TULDW) without its cover. With cover it is 61” tall 42” wide. Its depth of only 16” includes the 3” double wall area that surrounds the inner tank. This series of tanks can be U/L Listed (see page DT-1). DOUBLE WALL TANKS and RUPTURE BASINS Please refer to sidebar on page DT-3 - Secondary Containment. The Content Herein Is Subject To Change Without Notice. P.O. Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 DT-5 TRIM DAY TANKS SINGLE-WALL TANK SIZE [1] BASIC SERIES MODEL CODE U/L LISTED SERIES WEIGHT * (Lbs) MODEL CODE U/L VENT DRAWING PAGE REF WEIGHT TANK (Lbs) 150% R/B ** 200% R/B ** 10 PY10T 139 PY10TUL 2” 142 DT-23 DT-31 DT-33 25 PY25T 167 PY25TUL 2” 171 DT-24 DT-32 DT-34 50 PY50T 254 PY50TUL 2” 258 DT-24 DT-32 DT-34 60 PY60T 262 PY60TUL 3” 268 DT-24 DT-32 DT-34 75 PY75T 270 PY75TUL 3” 276 DT-24 DT-32 DT-34 100 PY100T 285 PY100TUL 3” 292 DT-24 DT-32 DT-34 DOUBLE-WALL BASIC SERIES TANK SIZE MODEL CODE U/L LISTED SERIES WEIGHT * (Lbs) MODEL CODE U/L VENT DRAWING PAGE REF WEIGHT TANK (Lbs) 150% R/B ** 200% R/B ** 10 PY10TDW 242 PY10TULDW 2” 247 DT-23 DT-31 DT-33 25 PY25TDW 311 PY25TULDW 2” 315 DT-24 DT-32 DT-34 50 PY50TDW 496 PY50TULDW 2” 500 DT-24 DT-32 DT-34 60 PY60TDW 527 PY60TULDW 3” 534 DT-24 DT-32 DT-34 75 PY75TDW 535 PY75TULDW 3” 542 DT-24 DT-32 DT-34 100 PY100TDW 574 PY100TULDW 3” 581 DT-24 DT-32 DT-34 * WEIGHTS ARE APPRXIMATE DEPENDING UPON ATTACHED OPTIONS, ETC. **1R/B—RUTURE BASIN See Page DT-1 For U/L Listed Emergency Vent Sizing. The Content Herein Is Subject To Change Without Notice. P.O. Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 DT-6 RUPTURE BASINS All of Pryco’s day tanks (including double walled versions) may be fitted within an open-top secondary container or dike referred to at Pryco as a Rupture Basin. All Rupture Basins are U/L Listed - #MH12807 “Open Top Diked Aboveground Tank for Flammable Liquids”. Rupture Basins are available in either 150% (option #385) or 200% (option #386) models. Both are sized according to the accompanying inner-most day tank. Rupture Basins like all Pryco Tanks are fabricated of heavy gauge steel by certified welders. Since a Rupture Basin is open-dike, it cannot be pressure tested. Each Rupture Basin has a 1” NPT drain and a ½" NPT Threaded Pipe Connection for an optional #295 or #395 Leak Detector. Also as an option (#341) the inner tank drain may be piped through the outer shell. The Rupture Basins are painted Pryco (medium) Gray or an industrial color of choice. A Weatherproof Cover (Option # 335RB) with a plexi-glass inspection port may be included to preserve the integrity of a dry container especially when an optional leak detector is installed. LOCAL BUILDING and FIRE CODES Most municipalities have codes governing day tanks. Some are listed in the Options section of this manual. Check for local codes in your area. SEISMIC REINFORCEMENT All of Pryco’s Day Tanks can be fitted with seismic reinforcement. Ask for specifications of the earthquake versions of our tanks. Above is a weatherproof 200% Rupture Basin for this Double-Wall Day Tank. Another one is is shown on page DT-5 The Content Herein Is Subject To Change Without Notice. P.O. Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 DT-7 RUPTURE BASINS SECONDARY CONTAINMENT for DAY TANKS 150% RUPTURE BASINS TANK SIZE (U.S. GAL) OPTION CODE (150%) 200% RUPTURE BASINS WEIGHT WEIGHT (Lbs) (Lbs) Standard & Trim Day Manual Day Tanks Tanks OPTION CODE (200%) 200% R/BASINS for DOUBLE WALL TANKS WEIGHT WEIGHT (Lbs) (Lbs) Standard & Trim Day Manual Day Tanks Tanks) OPTION CODE (D/W 200%) 5-10 15 385/01 385/02 76 86 58 N/A. 386/01 386/02 87 87 77 N/A 385DW/01 25 385/03 93 123 386/03 108 105 385DW/03 50 385/04 161 135 386/04 169 169 385DW/04 60 385/05 172 165 386/05 183 183 385DW/05 75 385/06 198 182 386/06 207 210 385DW/06 100 385/07 223 206 386/07 249 247 385DW/07 150 385/08 274 386/08 325 385DW/08 200 385/09 396 386/09 457 385DW/09 275 385/10 468 386/10 531 385DW/10 300 385/11 485 386/11 537 385DW/11 400 385/12 537 386/12 603 385DW/12 500 385/13 640 386/13 652 600 385/14 718 386/14 694 700 385/15 785 386/15 743 385DW/15 800 385/16 854 386/16 791 385DW/16 900 385/17 911 386/17 840 385/DW17 385/18 992 386/18 888 385DW/18 1000 NOTES N/A 385DW/02 385DW/13 N/A 385DW/14 1. The minimum capacity of secondary containment is based upon either 150% or 200% of the capacity of the inner-most tank. For example Option #385/09 a 150% Rupture Basin for a 200 gallon day tank has a minimum capacity of 300 gallons; whereas Option #386/09 a 200% Rupture Basin for a 200 gallon day tank will hold at least 400 gallons. 2. A single wall day tank will fit in either a 150% or a 200% Rupture Basin. A double wall day tank will DIMENSIONAL CHART DRAWINGS REFERENCE DAY TANK SIZE RUPTURE BASIN (BASIC & U/L) - 150% RUPTURE BASIN (BASIC & U/L) - 200% Standard & Manual Trim Tanks Standard & Manual Trim Tanks 10—25 DT-25 DT-31 DT-28 DT-33 50—150 DT-26 DT-32 DT-29 DT-34 200—1000 DT-27 n.a. DT-30 n.a. Generalized Drawings for all Pryco day tanks and rupture basins may be downloaded in PDF format from our website www.Pryco.com The Content Herein Is Subject To Change Without Notice. P.O. Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 DT-8 SUB-BASE TANKS Pryco’s Sub-base Tanks are designed specifically for generator set mounting. The physical size of each depends upon the foot print of the gen set and required capacity. Sub-base Tanks are available in a Standard or a U/L Listed design. The features and characteristics of all sub-bases are listed on page SB-4 Additionally, a Standard or U/L Listed Subbase may be fitted with Double-Wall construction (“Secondary Containment”). Custom designed tanks are available to accommodate large capacity Double Wall and Rupture Basin requirements. All sub-base tanks comply with NFPA 30, Flammable and Combustible Liquids Code and NFPA 110, Standard or Emergency and Standby Power Systems. When the secondary container “double wall” is added, the tank also complies with NFPA 37 - Standard for Installation and Use of Stationary Combustible Engine and Gas Turbine. Consult factory for dimensions and pricing. A Single Wall Sub-base showing heavy duty support angles that are located, along with internal structural baffles, at each mounting hole. U/L LISTED SUB-BASE TANKS GEN-SET MOUNTING The U/L Listing for our Sub-base Tanks is - Label-142. Specifically, File #MH17469 lists the following: • Basic Sub-base Tanks - Generator Base Tanks, • Double Wall Sub-base Tanks - Secondary Containment Generator Base Tank, and • Sub-base Tanks with Rupture Basin - Open Top Diked Generator Base Tank. The below restrictions apply to U/L Listed tanks: • Each U/L Listed tank has additional vents of proper size for the tank and the double wall area, if present. • Width cannot exceed 82” and height cannot exceed 30” • Capacity - not to exceed 2000 gallons Mounting of the gen-set to the sub-base at the job site could cost considerable time and money. We’ll do it for you here at the factory at a fraction of the cost. Just have your gen-set (and isolator, if any) shipped to us and tell us what you want done. In addition to the actual bolting of the two together and connecting the fuel line, we will make other connection that you request. When finished, we will send it on to your job site or where instructed. Catalog Number — 0011.0 (Dec. 2012) The Content Herein Is Subject To Change Without Notice. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 SB-1 SUB-BASE OPTIONS Option Code Description 503 LOW FUEL LEVEL ALARM - Separate float switch activates red light 504 HEAVY DUTY SOCKET and RELAY for Option #503 (10 amp. relay, dry contacts) 505 LOW FUEL LEVEL SWITCH - Separate float switch for remote annunciator only. (10 watts, dry contacts) 507 HIGH FUEL LEVEL ALARM - Separate float switch activates red light 508 HEAVY DUTY SOCKET and RELAY for Option #505 (10 amp. relay, dry contacts) 509 HIGH FUEL LEVEL SWITCH - Separate float switch for remote annunciator only. (10 watts, dry contacts) 509RB LEAK DETECTOR SWITCH - Rupture Basin or Double Wall (10 watts, dry contacts) 530 2” RAISED MANUAL FILL - with lockable cap, 8” high (ship loose). 531 EXTRA FITTING through double wall (up to 2”) 532 ADDITIONAL SET of GEN-SET MOUNTING HOLES (over 3 sets). 533 MOUNTING RAILS to bolt gen-set to wider tanks 534 “BOLT-ON” END for stub up (not for Custom tanks) 535 “BOLT-ON” EXPANDED METAL END for stub up (not for Custom tanks) GENERATOR SET MOUNTING - Route your gen-set to Pryco to be mounted to your Subbase Tank, connect fuel lines and ship on to job site or your facility. 536A up to and including a 500 kW gen-set 536B a gen-set over 500 kW 537 ISOLATOR PADS - attached at each mounting point to receive spring isolators supplied by others. 540 ENCLOSURE – For Level Sensors (Used Primarily for Day Tank versions) ENCLOSURE – For Control Panel (Used Primarily for Day Tank versions) 544 NEMA-1 544WP NEMA-3R 595 595M LEAK DETECTOR FOR DOUBLE WALL TANKS WITH PUMP AND MOTOR (Day Tank Version of Sub-base) - A sensor within the Double Wall containment area that upon detection of a leak will turn on a red alarm light on control panel and will shut down pump motor. Includes dry terminal contacts for connection of customer supplied device up to 15 amp. LEAK DETECTOR FOR DOUBLE WALL MANUAL TANKS — A sensor within the Double Wall containment area that upon detection of a leak will turn on a red alarm light on control panel. Includes dry terminal contacts for connection of customer supplied device up to 15 amp. The Content Herein Is Subject To Change Without Notice. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 SB-2 OPTIONAL CONDUIT STUB UP P.O. Box 108, Mechanicsburg, IL 62545 SB-3 STRUCTURAL BAFFLE (TYPICAL EACH MTG HOLE) J K L I TOP VIEW UV G H PIPED THROUGH INNER TANK DRAIN HOT / COLD BAFFLE TO SEPARATE RETURN FROM SUPPLY FUEL RIGHT SIDE LEFT SIDE STRUCTURAL SUPPORT ANGLES (2 EACH TYPICAL AT MTG HOLES) GENSET MOUNTING HOLES (TOP FLANGE) FLOOR MOUNTING HOLES (BOTTOM FLANGE) 1/2" NPT FOR OPTIONAL LEAK DETECTOR SWITCH w/WEATHERPROOF ENCLOSURE SIDE VIEW DIMENSION CODE ASSIGNMENT 1" x 1/2" NPT FOR ENGINE SUPPLY 2" NPT MANUAL FILL w/LOCKING CAP 2" NECK - FUEL LEVEL GAUGE 1" NPT FOR OPTION PORT 2" NPT FOR REQUIRED TANK VENT 1" x 1/2" NPT FOR ENGINE RETURN 2" NPT FOR DOUBLE WALL VENT STANDARD OPENINGS CODE ASSIGNMENT OVERALL TANK LENGTH LIQUID (INNER TANK) LENGTH OVERALL TANK WIDTH OVERALL TANK HEIGHT TOP MOUNTING HOLES - CENTER TO CENTER WIDTH DISTANCE BETWEEN FIRST AND LAST MOUNTING HOLES DISTANCE FROM RADITOR END TO FIRST MTG HOLE LIQUID (INNER TANK) WIDTH BOTTOM MOUNTING HOLES - CTR TO CTR WIDTH TANK TOP, SIDE CHANNELS & SUPPORTS - 7ga TANK & DOUBLE WALL BOTTOMS & ENDS - 12ga LOAD CAPACITY - 28,000 LBS CONSTRUCTION NOTES U/L LISTED RELATED CODES UVD 2" to 6" NPT U/L EMERGENCY RELIEF VENT FOR D/W UV 2" to 6" NPT U/L EMERGENCY RELIEF VENT FOR TANK G H I J K L KD A AT B C D E F N X R UVD U L LISTED KD RADIATOR END VIEW EXAMPLE OF A DOUBLE WALL SUB-BASE TANK w/ELECTRICAL STUB-UP AREA RADIATOR END The Content Herein Is Subject To Change Without Notice. Phone - 217 / 364-4467 Fax - 217 / 364-4494 SUB-BASE TANKS SECONDARY CONTAINMENT DOUBLE WALL AREA PRIMARY LIQUID CONTAINMENT INNER-TANK AREA LEAK DETECTOR (OPTIONAL) INNER-TANK & DOUBLE WALL AREA TESTED TO 5 psi CONDUCT STUB-UP AREA 2” NPT - FILL w/CAP 1” NPT - ENGINE SUPPLY 1” NPT - ENGINE RETURN 1 1/2” NPT - LEVEL GAUGE 2” TO 6” NPT U/L VENT 2” NPT - EMERGENCY VENT A 3-D rendering showing some of the features of a double wall standard sub-base tank. CONSTRUCTION CHARACTERISTICS • Heavy Gauge Steel - 7-gauge steel for the top and side channels. Standard 12-gauge for bottom, ends, and internal baffles; however, optionally, 7-gauge may be specified throughout. Also, stainless steel is a great solution for a corrosive environment problem. • Internal Structural Baffles - located every mounting point and no more than 24 inches apart. These baffles contribute to the overall strength of the tank but allow free flow of fuel. • Hot/Cold Baffles - this baffle is located between the engine-supply and the fuel return ports. Its purpose is to separate the hotter returned fuel from the cooler supply fuel thus improving engine performance. • Drain - 3/8” in tanks up to 200 gallons and 1” in 200+ gallon tanks. Double wall tanks have a drain for both containment areas — the inner tank drain is “hard-plumbed” through the outer area. • Connections - (1 ea.) 1½” for fuel level gauge; (2 ea.) 2” NPT for lockable fill cap and for vent; (2 ea.) ½” for engine suction and for engine return; and (1 ea.) extra 1” opening for option, etc. Note these connections are located on either or both side(s) depending upon gen-set and your specifications. • Welded by Certified Welders and Supervisor tested to 5psi. • Finish - Primer and choice of industrial color enamel. The Content Herein Is Subject To Change Without Notice. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 SB-4 SUB-BASE TANKS INNER-TANK DRAIN STRUCTURAL INNER BAFFLE HOT / COLD FUEL SEPARATION / STRUCTURAL BAFFLE DROP TUBES STRUCTURAL SUPPORTS (TYP. AT MOUNTING POINTS) This rendering is the same sub-base tank shown on the preceding page — the inner tank top and the outer wall of a side channel is cut away to reveal interior construction features. ELECTRICAL CONDUIT STUB-UP AREA HOW TO ORDER Typically, an optional conduit stub-up area is located the full width of the generator end; however, it may be located anywhere within the the outer shell walls. It may be a two, three or four sided window or island. A stub-up in a double wall tank is also “double walled”. It’s easy - just tell us your gen-set make and model, size in gallon capacity, and any options (shown on page SB-2) you need. Our proprietary computer software, referring to our extensive gen-set database, determines physical footprint dimensions and other requirements of your gen-set. (Custom designs are also available.) PUMPING CAPABILITIES When equipped with a set of pump, motor and controls, the sub-base tank takes on the duties of a day tank with most control capabilities (see the Options section). Or, consider our powerful electronic FCM (™) for precise level control, and local and remote annunciation logging of all conditions. A priced quote and a drawing of three view of the tank is then developed and sent to you for review and/or approval. NOTE - Mounting Rails, option #533, are required for tanks wider than normal footprint width (caused by expanding the width). The Content Herein Is Subject To Change Without Notice. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 SB-5 TRAILERS An 8000 GVW Tandem Trailer, Model Number PTT8000, With A 150 Gallon Sub-Base Tank. When portability is essential, Pryco tank-trailers is a must. The tank, a sub-base tank (sold separately), is integrated into the design of the trailer. The actual design centers around the make and model of the gen-set and required total gross vehicle weight (GVW). The trailer frame and tongue are formed with extra heavy 7-gauge steel. The fenders and step pads are made of heavy gauge formed steel. The step pads also include non-skid surfaces. Standard equipment includes: • USDOT required lighting package: - Protected Brake Lights - Park Lights - Turn Lights - Side markerLights - License Plate Bracket • 3-foot Heavy Duty Safety Chains • Sand Shoe Tongue Jack • Ball Coupler • Primer & Black Enamel Finish or An Industrial Color Of Choice Rugged, heavy-gauge steel protects brake lights, turn lights and rear amber lights. Other lights are recessed into frame and fender steps. Optional accessories are shown on the next page. Catalog Number — 0011.0 (Dec. 2012) The Content Herein Is Subject To Change Without Notice. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 TR-1 TRAILERS TRAILER OPTIONS SINGLE AXLE TRAILERS MODEL NUMBER GVW (In lbs.) PTS1500 1500 PTS3500 3500 PTS4000 4000 PTS5000 5000 PTS6000 6000 TANDEM AXLE TRAILERS MODEL NUMBER GVW (In lbs.) OPT# 600 DESCRIPTION PARKING BRAKE with Hydraulic Actuator/ Coupler 610 611 612 ELECTRIC BRAKES - Single Axle 3,500 lbs. - Tandem Axle 7,000 lbs. - Tandem Axle 12,000 lbs. 620 621 SURGE HYDRAULIC BRAKES - Single Axle 6,000 lbs. - Tandem Axle 12,000 lbs. 630 STABILIZER JACK (Pair) - 1,200 lbs. each PTT4000 4000 640 SWIVEL JACK and WHEEL PTT5000 5000 650 TOWING RING PTT6000 6000 651 PTT7000 7000 ADJUSTABLE COUPLER and TOWING RING (Trailer Capacity Priced) PTT8000 8000 652 BREAK-AWAY KIT (Electric Brakes Only) PTT9000 9000 PTT10000 10,000 670 671 PAINT (other than Black) - Single Axle - Tandem Axle PTT12000 12,000 Pryco builds tank/trailers to your specifications. The Content Herein Is Subject To Change Without Notice. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 TR-2 PUMP SETS An open design duplex pump set (Model #PYPS1205) set up to be bolted to the floor. Pryco Pump Sets are high performance fuel system drivers. They are fully integrated, pre-plumbed and pre-wired for trouble-free, “connect and go” installation. We offer a wide range of configurations that will fulfill your requirements. They are intended to transfer #2 fuel oil within an emergency generator system or oil burners. The following configurations are available: • The PYPS1000 “Open Design” series — the components are mounted on a bracket with a drip pan that may be placed directly on the floor or may be ordered with an integrated heavy duty bracket on the back side for wall mounting. • The PYPS2000 “Enclosed Design” series — the components of the this design are mounted on a back-plate that is placed within an optional NEMA-1 or NEMA-3R enclosure (Option #338). The enclosure may be wall mounted or may be ordered with legs for floor installation. See page PS-4 for a description of the optional enclosures. • The PYPS3000 “Custom Design” series — for special requirements Refer to page PS-3 for a list of options that are commonly ordered with pump sets. Isolation valves provide for easy maintenance of the pump and motor system. Also, fuel filters/separators and pressure relief valves are ordered with most pump sets. A pump set can accommodate both a supply and a return system. The Content Herein Is Subject To Change Without Notice. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 PS-1 PUMP SETS For commercial and industrial reliability, we use positive displacement, self-lubricating, bronze rotary gear pumps with stainless steel shafts from Oberdorfer . We offer an assortment of six models of pumps ranging from 2 GPM up to 40 GPM. (Shown to the right is Oberdorfer’s #994 — 10GPM pump.) These pumps are close coupled to a motor chosen to match your flow rate and other specific requirements (refer to Pump/Motor Sizing on pages PS5 -PS6). A single 2-GPM pump and 1/3 HP motor (and related controls) are standard with all pump sets (“PYPS”) configurations. Optionally available are duplex and triplex pumps/motors (even a quadplex in custom designs) with lead/lag switching and sequencing. All models have common intake and output ports. The control system receives fuel level signals from our standard remote float switch design. Or, you may optionally choose our Fuel Control and Monitoring (FCM) system. Both control systems are housed in a NEMA-3R rated enclosure. Depending upon your requirements, the pump set may be housed within an optional NEMA-1 or NEMA-3R rated enclosure (see the ENCLOSURES section below). STANDARD FEATURES • • • • • • • • • • Fully Factory Assembled Heavy Gauge Steel throughout 2 GPM Pump & 1/3 HP Motor (same as day tanks) High Pressure, Crimp Hose connections for easy maintenance Drip Pan with ½ ” Drain Plug Port Priming Tee on intake (#312) 3” Formed Channel Legs on Pad Floor (PYPS1000) designs Common Ports - Suction & Discharge (Size: ½”, 1”, 1¼”, 1½”, and 2”) Interface with Tank Control Circuits Gray or Industrial Color Paint OPTIONAL ACCESSORIES Pump set accessories generally parallel those of a day tank. Shown on the next page is a list of those options that are most often chosen for pump sets. If an option is not shown here, check the “OPTIONS” section of this catalog. Also, if more pumping capacity or greater power is required, please refer to the later section — “Pump / Motor Sizing” . The Content Herein Is Subject To Change Without Notice. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 PS-2 PUMP SETS SUGGESTED OPTIONAL ACCESSORIES (See Options section for more details) OPTION CODE DESCRIPTION 313 Compound Pressure/Vacuum Gauge 314 Fuel Strainer 40 Mesh 315SGL Fuel Strainer 60 Mesh—Single Unit (315FLT— Replacement Filter & Gasket) 315DPX Fuel Strainer 60 Mesh—Duplex Unit w/Isolation Valves (315FLT— Replacement Filter & Gasket) 318SGL Fuel Filter / Water Separator (Facet) - Single (318FLT— Replacement Filter & Gasket) 318SGL Fuel Filter / Water Separator (Facet)—Duplex Unit w/Isolation Valves (318FLT— Replacement Filter & Gasket) 318 Fuel Filter / Water Separator (Racor) 318SGL—Single Separator Unit (Performance - 180 gph) 318DPX—Duplex Manifolld Unit (Performance - 360 gph) 318TRI—Tri-Manifolld Unit (Performance - 540 gph) 338 Enclosures, Pump Set (See ENCLOSURE Section page PS-4) 339 Enclosure Door Interlock with Circuit Breaker 355 Check Valve to prevent loss of prime 369 Manual Cut-Off Ball Valve for Pump Isolation 372 Flow Switch to detect “no fuel in line” condition 379 External Pressure Relief By-Pass Valve 400 Series Pumps and Motors 442 & 443 427 427A Pump(s) & Motor(s), other than standard, sized according to your specification Motor Starters Duplex (Second Standard) Pump and Motor Duplex Pump Alternator Transfer Switch (includes Second Standard Pump and Motor) The Content Herein Is Subject To Change Without Notice. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 PS-3 PUMP SETS ENCLOSURE When a vulnerable pump sets needs protection, our option #338 enclosures is the right answer. These NEMA1 and NEMA-3R enclosures feature: • • • heavy 12 gauge steel a lockable door with a continuous hinge (this can be complimented with an optional door interlock that requires the system to be shut down before the door is opened) protected openings for adequate ventilation The outside and inside view of an option #338 enclosure for a pump set similar to the one shown on page PS-1. The unit illustrated above has option #339, Door Interlock that requires the system to be shut down before the door is opened. The different configurations of enclosures are shown below: 338 CODE SUFFIX ASSOCIATED MODEL NUMBER NEMA RATING PUMP CONFIGURATION A PYPS2100 1 SINGLE PUMP B PYPS2200 1 DUPLEX PUMP C PYPS2100 3R SINGLE PUMP D PYPS2200 3R DUPLEX PUMP E PYPS1100 1 SINGLE PUMP F PYPS1200 1 DUPLEX PUMP G PYPS1100 3R SINGLE PUMP H PYPS1200 3R DUPLEX PUMP X PYPS3000 — (ALL) The Content Herein Is Subject To Change Without Notice. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 PS-4 OPTIONS Catalog Number — 0011.0 (Dec. 2012) The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-1 RECOMMENDED OPTIONS RECOMMENDED OPTIONAL ACCESSORIES The following optional equipment is recommended for most fuel systems with pump(s) and motor(s): 360 - SOLENOID VALVE — A normally closed solenoid valve that is installed on the pump intake to prevent tank flooding if the main storage tank is position above the day tank intake level; or, to prevent siphoning (backflow) if the main storage tank is located below the day tank inlet. It is automatically opened when the pump motor turns on. 315 - FUEL STRAINER — A 1" strainer intended for in-line installation to prevent debris from entering system. Includes a 60-Mesh replaceable cartridge. 399 - REVERSE FLOW CONTROL— A package that includes the plumbing, float switches, and other control devices and wiring necessary to return fuel to the main storage tank. Pump and motor are not included; however, we recommend a pump/motor combination that is at least one size larger that the supply pump/motor set. 210 - HIGH/LOW COMBINATION FUEL LEVEL ALARM — Dual separate float switches that activates a red light on control panel when the fuel rises to a pre-determined level (normally 102% capacity), and a different red light when the fuel falls to a pre-determined level (normally 75% capacity). 206 - CRITICAL LOW FUEL ALARM w/ENGINE SHUT DOWN — A separate float switch (normally set at 5% fuel level) that activates a red light on the control panel. It also activates a double pole relay that closes normally open contacts for 3 amp remote alarm annunication, and opens a normally closed contacts that will shut down the generator engine thus preventing loss of engine fuel prime. 213 - CRITICAL HIGH FUEL PUMP/MOTOR SHUT DOWN — A separate float switch that shuts off the pump motor when fuel rises to a 103% level. Also, a "Critical High" red light on the control panel is activated; a remote annunciation relay is closed and dry contacts are activated. And a "normally open" solenoid valve is closed to prevent further fuel from entering the tank. 385 - 150% RUPTURE BASIN — A U/L Listed (Label 142, File #MH12807), open-top dike, secondary containment used as insurance against day tank leak or rupture. Also recommended is a 395 - RUPTURE LEAK DETECTOR installed within a rupture basin that shuts down the pump motor; activates a "rupture detected" red light on the control panel; and, activates dry contacts for remote signal (15 amp). DW – DOUBLE WALL CONSTRUCTION — a totally enclosed outer shell , or the outer tank, independent of the inner day tank fuel storage area. Both the inner and outer tanks are vented separately and are pressure tested as described above. The outer tank has a provision for leak detection, venting, and a drain. The inner tank overflow port and drain are piped through the outer tank. The 395 Leak Detector (above) is used to monitor inner tank leakage. 321 - PRESSURE RELIEF VENT CAP — A pressure relief vent cap. The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-2 INDEX by CATEGORY ELECTRICAL ALARMS and SWITCHES—HIGH LEVEL 207 HIGH FUEL LEVEL ALARM …………………………………………………………... OP-9 208 REMOTE OUTPUT SIGNAL for Option 207 …………………………….…………... OP-9 209 HIGH FUEL LEVEL SWITCH …………………………………………………………. OP-9 213 CRITICAL HIGH FUEL ALARM w/PUMP MOTOR SHUTDOWN …………………. OP-10 222 HIGH FUEL LEVEL EXPLOSION-PROOF SWITCH ……………………………….. OP-12 ALARMS and SWITCHES—LOW LEVEL 203 LOW FUEL LEVEL ALARM ……………………………………………………………. OP-8 204 REMOTE OUTPUT SIGNAL for Option 203 …………………………….…………... OP-8 205 LOW FUEL LEVEL SWITCH …………………………………………………………... OP-8 206 CRITICAL LOW FUEL ALARM and ENGINE SHUTDOWN ……………………….. OP-9 220 LOW FUEL LEVEL HEATER SHUT-OFF SWITCH …………….…………………... OP-12 221 LOW FUEL LEVEL EXPLOSION-PROOF SWITCH ………………………………... OP-12 ALARMS and SWITCHES—HIGH/LOW COMBINATION LEVEL 210 COMBINATION LOW / HIGH FUEL LEVEL ALARM ……………………………….. OP-9 211 REMOTE OUTPUT SIGNAL for Option 210 …………………………….…………... OP-9 212 COMBINATION LOW / HIGH FUEL LEVEL SWITCH ……………………………… OP-9 ALARM HORNS 223 ALARM HORM, Compact (86dB @ 10 Ft) ………………………………................ OP-12 224 ALARM HORM, Weatherproof (103dB @ 10 Ft) ……………………….………….. OP-12 CIRCUIT BREAKERS 216-1x CIRCUIT BREAKER (Single Phase) ………………..……………......................... OP-11 216-3x CIRCUIT BREAKER (Three Phase) ……..…………..…………….……………….. OP-11 216-DC CIRCUIT BREAKER (DC Motors) …………………….……….............................. OP-11 EXTRENAL “DRY” CONTACTS 244 PUMP RUNNING DRY CONTACTS ………..……………………………................ OP-14 246 REMOTE SIGNAL DRY CONTACTS …………………………………….………….. OP-14 FLOAT SWITCHES and VALVES 214 EXPLOSION-PROOF FLOAT SWITCH (Replaces Std Float Switch) ..………….. 215 FLOAT VALVE (Replaces Standard Float Switch) …………………………………. 217 FLOAT SWITCH (Standard) ………………………………...................................... 218 DPDT FLOAT SWITCH (Replaces Standard Float Switch) ……………………….. OP-10 OP-10 OP-11 OP-11 HEATER and THERMOSTATS 219-A HEATER and THERMOSTAT (5 to 25 Gal. Tanks) ………………………………. OP-11 219-B/F HEATER and THERMOSTAT (50 to 1000 Gal. Tanks)…………..………………. OP-11 LEAK DETECTORS 209RB RUPTURE BASIN / DOUBLE WALL LEAK DETECTOR .................................... 209DW RUPTURE BASIN / DOUBLE WALL LEAK DETECTOR .................................... 295 LEAK DETECTOR for DOUBLE WALL TANK w/PUMP & MOTOR ………….... 295M LEAK DETECTOR for DOUBLE WALL MANUAL TANKS ……….……………... OP-9 OP-9 OP-14 OP-14 MANUAL CONTROL SWITCHES 202 PUMP RUN / OFF / AUTOMATIC SWITCH ……………………………...... ………. OP-8 240 ALARM TEST SWITCH ……..……………………….……………………….. ………. OP-14 242 ALARM SILENCE SWITCH …………………………….................................... …... OP-14 The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-3 INDEX by CATEGORY ELECTRICAL (continued) PILOT LIGHTS and REMOTE ANNUNICATION 200 PILOT LIGHT, GREEN — Power Available …………………………………………. 200R REMOTE ANNUNICATION for Option 200 …………………………….……………. 201 PILOT LIGHT, RED — Remote or Main Tank Low Fuel …………………………... 201R REMOTE ANNUNICATION for Option 201 …………………………….……………. 225 FLASHING LIGHT, YELLOW — “Attention Getter” for Any Alarm ………………... 225R REMOTE ANNUNICATION for Option 225 …………………………….……………. 244 REMOTE ANNUNICATION for Pump Running Contacts…………….…………….. OP-8 OP-8 OP-8 OP-8 OP-12 OP-12 OP-14 PUMP TRANSFER SWITCHES 427A AUTOMATIC PUMP MOTOR TRANSFER SWITCH ……………………...………. OP-26 427B MANUAL PUMP MOTOR TRANSFER SWITCH …………………………..………. OP-26 REMOTE FILL CONTROL 226 REMOTE FUEL FILL PANEL …………………………………………………………. 226PM ASSISTING PUMP and MOTOR for Option 226 ……………………………………. 230 REMOTE FUEL FILL STATION …………………………….………………………… 230PM ASSISTING PUMP and MOTOR for Option 230 ……………………………………. 232 FUEL DELIVERY CONTROL STATION …….…………….…………………………. 232PM ASSISTING PUMP and MOTOR for Option 232 ……………………………………. OP-12 OP-12 OP-13 OP-13 OP-13 OP-13 MECHANICAL COVERS and ENCLOSURES 334 COVERS — STANDARD, TRIM, & CERTAIN MANUAL DAY TANKS ………. 335 WEATHERPROOF COVERS ………………………………………………………. 335RB RUPTURE BASIN WEATHERPROOF COVERS ………………………………... 338 ENCLOSURE, PUMP SET …………………………………………………………. 339 ENCLOSURE DOOR INTERLOCK w/CIRCUIT BREAKER ……………………. 465 INDUSTRIAL CONTROL PANEL, ENCLOSED ………………………………….. DRAINS 340 341 342 343 345 350 OP-17 OP-18 OP-18 OP-18 OP-19 OP-26 DRAIN, PETCOCK VALVE (Tank Mounted) ……………………………….. ………. OP-19 DRAIN, PETCOCK VALVE (Piped Thru Rupture Basin & Double Wall) …………. OP-19 DRAIN, Tank Bottom Day Tank - Single Wall ………………….…………...………. OP-19 SIPHON DRAIN ASSEMBLY, For Tank-Top Drain …………….…………...………. OP-19 DRAIN, NOMINAL 10 GPM …………...……………………………………… ………. OP-19 DRAIN, NOMINAL 10 GPM EMERGENCY (Remote Activated) …………. ………. OP-19 FUEL STRAINERS & FILTERS 314 FUEL STRAINER, “Y”-TYPE ……………...………………………………….….……. OP-15 314 FUEL STRAINER, VERTICAL, SINGLE & DUPLEX.……………………….….……. OP-15 315 FUEL FILTER, SINGLE & DUPLEX ………….……………………………….………. OP-16 318 FUEL FILTER/WATER SEPARATOR, “F”-TYPE, SINGLE & DUPLEX …...……. OP-16 319 FUEL FILTER/WATER SEPARATOR, “R”-TYPE, SINGLE, DUPLEX & TRI .……. OP-16 GAUGES and METERS 313 COMPOUND GAUGE (Pump Pressure / Vacuum) ………………………... ………. 326 SIGHT GLASS, FUEL LEVEL ……………………………………………….. ………. 371 FUEL FLOW METER …………...……………………………………………………… 398 REMOTE READING FUEL LEVEL GAUGE ………………………………... ………. OP-15 OP-17 OP-22 OP-24 MANUAL FILL 301 MANUAL FUEL FILL w/LOCKING CAP ……………………………………...……… OP-14 302 MANUAL FUEL FILL CONNECTION THREADED — 2” NPT …………………..… OP-14 FILL SPILL CONTAINMENT 227 SPILL CONTAINMENT (WALL) — 7.5 GALLONS …………………………………. OP-12 229 DRIP BASIN — 1 GALLON ………………………………….………………………… OP-13 The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-4 INDEX by CATEGORY MECHANICAL (continued) OIL COOLERS 352 OIL COOLER …………………………………………………………………………... OP-19 353 TEMPERATURE SWITCH for OIL COOLERS …………..…………………………. OP-19 354 HIGH TEMPERATURE RETURN THERMOSTATIC VALVE …………………….. OP-19 PLUMBING 312 330 333 464 PRIMING TEE …………………………………………………………………………. EXTRA CONNECTION PORTS …………..…………………………………………. PIPED THROUGH EXTRA CONNECTION PORT ………………………………... PIPE STEMS …………………………………………………………………………... OP-15 OP-17 OP-17 OP-26 REMOTE PUMP UNITS 397 REMOTE PUMPING UNIT w/PUMP & MOTOR, Single, Dup., Tri., & Quad ……. OP-24 REVERSE FLOW SYSTEMS 399 REVERSE FLOW CONTROLLER ……………………………………………………. OP-24 RUPTURE BASINS 385 DAY TANK RUPTURE BASIN, 150% Day Tank Capacity…………………………. 386 DAY TANK RUPTURE BASIN, 200% Day Tank Capacity…………………………. 395 LEAK DETECTOR for RUPTURE BASIN for DAY TANK w/PUMP & MOTOR …. 395M LEAK DETECTOR for RUPTURE BASIN for MANUAL DAY TANKS ……….…… OP-23 OP-23 OP-23 OP-23 SOLENOID & MOTORIZED BALL VALVES 360 SOLENOID VALVE, Normally Closed ……….….……………………………….….. 361 SOLENOID VALVE, Normally Open, 2” (For Opts 226 & 230) ………………..….. 362 SOLENOID VALVE, Normally Open …………..………………….…………………. 364 SOLENOID VALVE w/MANUAL OVERRIDE, Normally Closed …………..……… 367 MOTORIZED BALL VALVE …………………………………………………………... OP-20 OP-20 OP-20 OP-21 OP-21 TANK MOUNTING and PIPE STAND ADAPTERS 305 WALL MOUNTING BRACKETS for DAY TANK …………………………………….. OP-15 310 PIPE STAND ADAPTERS of DAY TANK ……………………………………………. OP-15 VALVES and SWITCHES 355 369 370 372 373 374 375 376 379 380 381 CHECK VALVES ………………………………………………………………………………….. CUT-OFF VALVES—PUMP SETS ……………………………………………………………... CUT-OFF VALVES—DAY TANKS ……………………………………………………………... FLOW SWITCH …………………………………………………………………………………... TIME DELAY RELAY …………………………………………………………………………….. FUSE-LINK VALVE for Fire Safety …………………………………………………………….. FOOT VALVE (Ships Loose For Main Storage Tank) ……….……………………………… FOOT VALVE (Day Tank Installed) …………………………………………………………… PRESSURE RELIEF BY-PASS VALVES—IN-LINE …………………………………………. PRESSURE RELIEF BY-PASS VALVES—PUMP……………………………………………. FLAME ARRESTOR ……………………………………………………………………………... OP-19 OP-21 OP-21 OP-22 OP-22 OP-22 OP-22 OP-22 OP-22 OP-22 OP-22 VENTING DEVICES 320 321 322 323 324 VENT CAP—MUSHROOM ……………………………………………………………………… VENT CAP—PRESSURE RELIEF ……………………………………………………………... VENT KIT—SINGLE WALL TANKS ……………………………………………………………. VENT KIT—DOUBLE WALL TANKS …………………………………………………………... VENT OVERFLOW DETECTOR …………………………….…………………………………. OP-16 OP-16 OP-16 OP-17 OP-17 The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-5 INDEX by CATEGORY PUMPS BRONZE PUMPS 400 thru 405 BRONZE GEAR PUMPS (2 GPM to 40 GPM) ……………………………………… OP-25 CAST IRON PUMPS PCI06 thru PCI62 PCI03R thru PCI15R CAST IRON GEAR PUMPS (6 GPM to 62 GPM) ………………………... OP-25 CAST IRON GEAR PUMPS w/PRESSURE RELIEF, (3 GPM to 13 GPM) …………………………………………………………. OP-25 HAND PUMPS 461 HAND PUMP—PISTON …………………………………………………………………………. OP-26 462 HAND PUMP—ROTARY ………………………………………………………………………... OP-26 DUPLEX PUMPING SYSTEMS 427 DUPLEX PUMP and MOTOR (Second)……………………………………………………….. OP-26 427A AUTOMATIC TRANSFER SWITCH and CONTROLS ………………………………………. OP-26 427B MANUAL TRANSFER SWITCH and CONTROLS …………………………………………... OP-26 MOTORS A/C & D/C MOTORS 1/4 HP, 12 vdc and 24-28 vdc …………………………………………………………………………... 1/3 HP, 120 vac, 230 vac, & 460 vac …………………………………………………………………... 1/2 HP, 12 vdc and 24-28 vdc …………………………………………………………………………... 1/2 HP, 120 vac, 230 vac, & 460 vac …………………………………………………………………... 3/4 HP, 120 vac, 230 vac, & 460 vac …………………………………………………………………... 1 HP, 120 vac, 230 vac, & 460 vac …………………………………………………………………... 2 HP, 120 vac, 230 vac, & 460 vac …………………………………………………………………... OP-27 OP-27 OP-27 OP-27 OP-27 OP-27 OP-27 MOTOR STARTERS — A/C 442 & 443 Single and Triple Phase, respectively ………………...……………………………… OP-2 STANDARD PUMP and MOTOR 463 Standard Pump & Motor (Purchased Separately) …………………………………………….. OP-26 ELECTRONIC CONTROLLERS 700 FUEL CONTROL MODULE (FCM) and OPTIONS …………………………………………………... OP-29 800 EVOLUTION PLC and OPTIONS …………………………..…………………………………………... OP-30 The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-6 INDEX by CATEGORY BATTERY BOXES & FRAMES BATTERY BOXES and FRAMES BB01 thru BB04 BATTERY BOXES for 4D & 8D Batteries ……………………………………… OP-32 BF01 thru BF04 BATTERY FRAMES for 4D & 8D Batteries ……………………………………. OP-32 BFS01 thru BSF04 SEISMIC BATTERY FRAMES for 4D & 8D Batteries ………………………... OP-32 PUMP SET OPTIONS PUMP SET OPTIONS Also selection from Electrical, Mechanical, Pumps & Motors options. 338 ENCLOSURE, PUMP SET ……………………………………………………………………... PS-3 339 ENCLOSURE DOOR INTERLOCK w/CIRCUIT BREAKER ………………………………... PS-3 SUB-BASE TANK OPTIONS SUB-BASE TANK OPTIONS Also, for Day Tank versions, select from Electrical, Mechanical, Pumps & Motors options. 503 LOW FUEL LEVEL ALARM …………………………………………………………………….. SB-2 504 REMOTE ANNUNICATION for Option 503 …………………………….……………………... SB-2 505 LOW FUEL LEVEL SWITCH ……………………………………………………………………. SB-2 507 HIGH FUEL LEVEL ALARM ……………………………………………………………………. SB-2 508 REMOTE ANNUNICATION for Option 507 …………………………….……………………... SB-2 509 HIGH FUEL LEVEL SWITCH …………………………………………………………………... SB-2 509RB REMOTE ANNUNICATION for Option 509 …………………………….……………………... SB-2 595 LEAK DETECTOR for DOUBLE WALL SUB-BASE TANKS w/PUMP & MOTOR ……….. SB-2 595M LEAK DETECTOR for DOUBLE WALL MANUAL SUB-BASE TANKS ………...………….. SB-2 TANK TRAILER OPTIONS TANK TRAILER OPTIONS 600 PARKING BRAKE ……………………………………………………………………………….. 61x ELECTRIC BRAKES …………………………….……………………………………………… 62x SURGE HYDRAULIC BRAKES ………………………………………………………………... 630 STABILIZER JACK ………………………………………………………………………………. 640 SWIVEL JACK & WHEEL ………………………………………………………………………. 650 TOWING RING …………………………………………………………………………………... 651 COUPLER & TOWING RING, ADJUSTABLE ………………………………………………... 652 BREAK-AWAY KIT for option 61x ……………………………………………………………... 67x PAINT (other than Pryco Gray) …………………………………………………………………. TR-2 TR-2 TR-2 TR-2 TR-2 TR-2 TR-2 TR-2 TR-2 COMMONLY REQUESTED PARTS LIST PARTS …………………………... ……………………… …………………………………………………………. OP-33 The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-7 ELECTRICAL OPTIONS ELECTRICAL OPTIONS 120vac voltage is assumed for all electrical components. 230vac, 12vdc, 24vdc, and most industry-standard special voltages may also be specified. Option Code 200 Description POWER AVAILABLE LAMP — A Green pilot light that when lit Indicates the control and/or motor circuits are energized and the system is ready. For remote signal, add — 200R REMOTE SIGNAL PROVISION, POWER AVAILABLE — Components to provide a heavyduty, output remote signal of the Power Available Lamp (option #200). Includes dry terminal contacts for connection of customer supplied device up to 3 amp. 201 LOW FUEL SUPPLY IN MAIN TANK LAMP — A Red pilot light that when lit indicates LOW FUEL LEVEL in the remote source tank (normally the main storage tank). Signal from external tank must be supplied by customer. Includes dry terminal contacts for connection of customer supplied input device up to 3 amp. Specify incoming voltage. For remote signal, add — REMOTE SIGNAL PROVISION, LOW FUEL SUPPLY IN MAIN TANK — Components to pro201R vide a heavy-duty, output remote signal of the Low Fuel Supply In Main Tank Lamp (option #201). Includes dry terminal contacts for connection of customer supplied device up to 3 amp. 202 PUMP RUN-OFF-AUTOMATIC SWITCH - Three position selector switch that replaces “PressTo-Test” switch. Normally there is one for each pump control system. Includes Power Available Lamp (Option #200). In the ON position, it overrides the float switch to turn on the motor (and pump). In the OFF position is used to turn off all power to the control system for the associated pump. In the AUTO position (normal), the float switch has control of the start and stop of the pump motor. 203 204 205 LOW FUEL LEVEL ALARM — A separate float switch which activates a Red pilot light on the control panel when fuel falls below a preset level (normally 75% fuel capacity). For remote signal, add — REMOTE SIGNAL PROVISION, LOW FUEL LEVEL ALARM — Components to provide a heavy-duty, output remote signal of the Low Fuel Level Alarm (option #203). Includes dry terminal contacts for connection of customer supplied device up to 3 amp. LOW FUEL LEVEL SWITCH — A separate float switch that activates a remote outgoing signal when the fuel falls to a predetermined level (normally 75% fuel capacity). Includes dry terminal (30-watt) contact. The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-8 ELECTRICAL OPTIONS Option Code Description 206 CRITICAL LOW FUEL ALARM w/ENGINE SHUTDOWN — A separate float switch that activates a red light on the control panel when the fuel level reaches a critical low level -- normally 5% fuel capacity of the tank. It opens a set of normally closed contacts that will shut down the generator engine thus preventing loss of engine fuel prime. Includes a double pole relay that closes a normally open contacts for a 3 amp remote outgoing signal. 207 208 209 HIGH FUEL LEVEL ALARM — A separate float switch which activates a red pilot light on the control panel when fuel fills beyond a preset level (normally 102%). For remote signal, add — REMOTE SIGNAL PROVISION, HIGH FUEL LEVEL ALARM — Components to provide a heavy-duty, remote signal of the High Fuel Level Alarm (option #207). Includes dry terminal contacts for connection of customer supplied device up to 3 amp. HIGH FUEL LEVEL SWITCH — A separate float switch that activates a remote outgoing signal when the fuel rises to a predetermined level (normally 102% capacity). Includes dry terminal (30-watt) contacts. 209RB RUPTURE BASIN or DOUBLE WALL LEAK DETECTOR SWITCH — A sensor switch located or within the secondary containment area. 209DW Includes dry terminal (30-watt) contacts. 210 211 212 HIGH / LOW COMBINATION FUEL LEVEL ALARM — Dual separate float switches that activates red lights on control panel when a low or high fuel level is sensed. HIGH - (See option #207) LOW - (See option #203) For remote signal, add — REMOTE SIGNAL PROVISION, HIGH / LOW COM-BINATION FUEL LEVEL ALARM — Components to provide a heavy-duty, remote signal of the High / Low Combo Fuel Level Alarm (option #210). Includes dry terminal contacts for connection of customer supplied device up to 3 amp. COMBINATION HIGH/LOW FUEL LEVEL SWITCH — Dual separate float switches to provide remote signaling of high and low fuel level conditions. LOW - (See option #205) HIGH - (See option #209) The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-9 ELECTRICAL OPTIONS Option Code Description CRITICAL HIGH FUEL ALARM w/PUMP MOTOR SHUTDOWN — This switch/alarm assembly prevents tank overfilling when the fuel level reaches a critical high level - normally 3-inches from the top of the tank or 103%. 213 Tanks with a pump / motor system — a separate float switch activates a red alarm light on the tank control panel, shuts down pump motor(s), and closes a normally open solenoid valve that is installed at fuel inlet. To specify solenoid valve voltage and inlet pipe size, use option codes 213A thru 213H shown below. 213 OPTION CODES 214 PIPE SIZE 120vac 230vac 12vdc 24vdc 1/2” 213A-120 213A-230 213A-D12 213A-D24 1” 213B-120 213B-230 213B-D12 213B-D24 1 1/2” 213C-120 213C-230 213C-D12 213C-D24 2” 213D-120 213D-230 213D-D12 213D-D34 EXPLOSION PROOF FLOAT SWITCH — This switch assembly has the same functionality as our standard float switch but all components are explosion proof, except the contactor, which is housed within an explosion proof enclosure. This float switch normally replaces the Standard Float Switch, option #217. 215 FLOAT VALVE — This option is used when a day tank is gravity fed from a main storage tank. Includes special inspection plate. Although technically it is not an electrical item, it replaces the standard float switch (option 217). Therefore, there is no electrical level control and annunciation directly associated with this option. This float valve normally replaces the Standard Float Switch, option #217. CIRCUIT BREAKER — This option, which includes the breaker(s) and an enclosure, is used to protect pump motors. The actual breaker is sized according to the ampere draw of the motor(s) and voltage. Standard breaker sizes are: 216 216-1-10 216-1-15 216-1-20 216-1-30 216-2-15 Single pole, Single Phase, A/C — 10 Amp. Single pole, Single Phase, A/C — 15 Amp. Single pole, Single Phase, A/C — 20 Amp. Single pole, Single Phase, A/C — 30 Amp. Double pole, Single Phase, A/C — 15 Amp. 216-3-15A 230 vac, Three Phase — 15 Amp. 216-3-15B 460 vac, Three Phase — 15 Amp. 216-DC All D/C motors - Up to 30 Amp. The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-10 ELECTRICAL OPTIONS Option Code 217 Description FLOAT SWITCH (Standard) — This switch controls the start and stop of the pump motor. There are two sensors: an ON sensor normally set at the 86% level, and an OFF sensor that is normally set at the 100% level. This option includes a bypassing “press-to-test” momentary contact switch to manually test the pump motor, and an amber pump-running light. The contactor has two N.O. and two N.C. secondary terminals that is rated at 15 amps. 218 DOUBLE POLE/DOUBLE THROW (DPDT) FLOAT SWITCH (Replaces Standard Float Switch #217) — This switch functions the same as our Standard Float Switch (option 217) with the exception that this switch has two N.O and two N.C. secondary terminals and is rated at 15 amps. Each contactor has its own float switch. This option includes a bypassing “press-to-test” momentary contact switch to manually test the pump motor, and an amber pump-running light. 219 HEATER & THERMOSTAT — An assembly used to heat the fuel oil inside a tank to maintain a specified temperature. While the thermostat controls the on/off of the actual heater to achieve desired fuel temperature, a float switch and relay monitors fuel level If the fuel drops below a pre-set level of 1” above the heater, the heater is shut off regardless of the temperature. This is to protect the heater from “burn-out”. 219 OPTION CODES TANK MODEL SIZE, WATTS & VOLTAGE 220 SINGLE WALL TANK DOUBLE WALL TANK RUPTURE BASIN PY5 - PY25 — 300w,120vac 219A 219A-DW 219A-RB PY50 - PY100 —- 1000w,120vac 219B 219B-DW 219B-RB PY150 - PY300 — 1500w, 120vac 219C 219C-DW 219C-RB PY400 - PY500 — 1500w, 120vac 219D 219D-DW 219D-RB PY600 - PY800 — 4000w, 240vac 219E 219E-DW 219E-RB PY900 - PY1000—8000w, 240vac 219F 219F-DW 219F-RB MULTIPLEX REMOTE PUMP/MOTOR CONTROLLER — An automatic transfer switching device used to control alternating remote pumps/motors pumping fuel from main storage tank to any number day tanks. The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-11 ELECTRICAL OPTIONS Option Code Description 221 EXPLOSION PROOF LOW LEVEL SWITCH — An explosion-proof sensor that activates remote outgoing signal when the fuel falls to a pre-determined level. Includes dry terminal (30-watt) contacts and normally closed (N/C) contactor. Terminals located in explosionproof box. 222 EXPLOSION PROOF HIGH LEVEL SWITCH — An explosion-proof sensor that activates remote outgoing signal when the fuel rises to a pre-determined level. Includes dry terminal (30-watt) contacts and normally closed (N/C) contactor. Terminals located in explosionproof box. 223 ALARM HORN, COMPACT — This horn is a compact design, vibrating AC or DC horn with low power drain that normally surface mounts on a control panel. Sound output is 104 dB at one foot (86 dB at 10 ft.). It is intended for indoor use. 224 ALARM HORN, WEATHERPROOF — A low-current, high decibel vibrating horn for heavyduty indoor/outdoor use. Sound output is adjustable over a 25 dB range from 78 dB to 103 dB (10 feet). 225 FLASHING LIGHT - YELLOW — Used as an “attention getter”, this option may be used in most any alarm circuit. Please specify associated alarm option. 225R 226 For remote signal, add — REMOTE SIGNAL PROVISION, FLASHING LIGHT - YELLOW — Components to provide a heavy-duty, remote signal of the Flashing Light, Yellow (option #225). Includes dry terminal contacts for connection of customer supplied device up to 3 amp. REMOTE FUEL FILL PANEL — A NEMA 3R enclosure, remotely mounted that is used to monitor tank fuel level filling activities. At 90% fuel fill, alarm horn ctivates and a light illuminates (alarm horn and silence switch included). At 95% an alarm horn sounds, light illuminates, and an optional N/O solenoid valve (opt #361),if installed, closes allowing no more fuel to enter tank. 226FM WALL-FLUSH MOUNTING of REMOTE FUEL FILL PANEL — Necessary brackets needed to recess panel enclosure (not door) into wall. 226PM ASSISTING PUMP and MOTOR for REMOTE FUEL FILL PANEL — The controls, brackets, etc. necessary to mount a single pump and motor to pump fuel to a non-gravity fill main storage tank. NOTE: Specify / order pump and motor separately according to requirements. 227 SPILL CONTAINER - 7.5 gallon container that is wall or pedestal mounted, that is used to prevent over-spill from contaminating soil, floor, etc. High speed drain valve included. 227-2 2” NPT Outlet connection 227-3 3” NPT Outlet connection 227-4 4” NPT Outlet connection The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-12 ELECTRICAL OPTIONS Option Code 229 230 Description DRIP BASIN - one gallon container, lockable with gasket for manual filling of Day Tank or Subbase. 2” NPT Outlet connection REMOTE FUEL FILL STATION — A lockable, NEMA 3R, dual-door enclosure designed to accommodate delivery truck curb-side filling of storage tank via hose connection. Inside are two compartments: the right side has a brass Cam-and-Groove fitting, a check valve, a manual shut-off valve, and a 7-1/2 containment sump; the left (isolated) side has the electrical components required to monitor fuel activities and report abnormal conditions. When the tank being filled reaches a 90% set point, a warning light comes on and an alarm horn sounds. If filling continues, a second light comes on at 95% capacity and an alarm horn again sounds. At this time, an optional solenoid valve (opt 361) will close allowing no more fuel to enter the tank. A silence switch and remote contact outputs are standard. 230-22 2” Cam-and-Groove fill and 2” plumbing and outlet 230-32 3” Cam-and-Groove fill and 2” plumbing and outlet 230-33 3” Cam-and-Groove fill and 3” plumbing and outlet 230FM WALL-FLUSH MOUNTING of REMOTE FUEL FILL STATION — Necessary brackets needed to recess panel enclosure (not door) into wall. 230PM ASSISTING PUMP and MOTOR for REMOTE FUEL FILL STATION — The controls, brackets, etc. necessary to mount a single pump and motor to pump fuel to a non-gravity fill main storage tank. NOTE: Specify/order pump and motor separately according to requirements. 232 FUEL DELIVERY CONTROL STATION — A lockable, weatherproof, enclosure with a 20gallon spilled fuel containment area. The 2”or 3” main fuel line features: a brass Cam-and-Groove fitting for standardized lock-on filling; an isolation ball valve; a check valve to prevent “back-fill” flooding Any spilled fuel falls into the 20-gallon sump where it can be either manually drained or pumped back into the main fuel line using an included hand pump. 232-22 2” Cam-and-Groove fill and 2” plumbing and outlet 232-32 3” Cam-and-Groove fill and 2” plumbing and outlet 232-33 3” Cam-and-Groove fill and 3” plumbing and outlet 232PM ASSISTING PUMP and MOTOR for FUEL DELIVERY CONTROL STATION — The controls, brackets, etc. necessary to mount a single pump and motor to pump fuel to a nongravity fill main storage tank. NOTE: Specify / order pump and motor separately according to requirements. The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-13 ELECTRICAL OPTIONS Option Code Description 240 ALARM TEST SWITCH — A momentary contact switch that tests all alarm circuits (alarm contactors, lights, and horn, if installed). 242 ALARM SILENCE SWITCH — A momentary contact switch that resets sounding alarm. 244 PUMP RUNNING CONTACTS — A provision for heavy-duty, remote signal indicating a pump is running. Includes dry terminal contacts for connection of customer supplied device up to 3 amp. REMOTE SIGNAL DRY CONTACTS — Components to provide a heavy-duty, remote signal of a specified alarm. Dry terminal contacts for connection of customer supplied device up to 3 amp. This option varies depending upon contactor requirement: 246-1C1O One Normally Closed & One Normally Open 246-1C3O One Normally Closed & Three Normally Open 246-2C2O Two Normally Closed & Two Normally Open FUEL LEVEL TRANSMITTER - 4-20MA—An ultra-sonic sensor to detect fuel level depth and convert it to a 4-to-20 ma signal. 250A The maximum tank depth cannot exceed 80 inches 250B The maximum tank depth cannot exceed 120 inches 290 Enclosure-Parts Only— control panel NEMA-1-UL-508 Compliant 290WP Enclosure-Parts Only— control panel NEMA-3R-UL-508 Compliant 295 LEAK DETECTOR FOR DOUBLE WALL TANKS WITH PU0MP AND MOTOR - A sensor within the Double Wall containment area that upon detection of a leak will turn on a red alarm light on control panel and will shut down pump motor. Includes dry terminal contacts for connection of customer supplied device up to 15 amp. 295M LEAK DETECTOR FOR DOUBLE WALL MANUAL TANKS — A sensor within the Double Wall containment area that upon detection of a leak will turn on a red alarm light on control panel. Includes dry terminal contacts for connection of customer supplied device up to 15 amp. The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-14 MECHANICAL OPTIONS MECHANICAL OPTIONS Option Code Description MANUAL FUEL FILL w/LOCKING CAP — 2” NPT, Used on Standard and Trim Day Tanks for manual filling, or fuel inlet from an Option 230, Remote Fuel Fill Station, or Option 232, Fuel Delivery Control Station. Includes Option 302. 301 301A 5-Gallon (PY5) Tanks 301B 10 to 150 Gallon (PY10 to PY150) Tanks 301C 200 and Above Gallon (PY200 and Above) Tanks 302 MANUAL FUEL FILL, THREADED — 2” NPT connection and drop tube in tank. Does not include locking cap 303 MANUAL FUEL FILL, OVERFILL PREVENTION — Features a 2” Cam-and-Groove coupling inlet for fuel truck filling. An internal valve requires 5 psi of incoming fuel pressure to force a float to close when fuel level rises to 4” from top of the tank. WALL MOUNTING BRACKETS, DAY TANKS - 5 thru 25 gallon tanks. 305 305-05 5 gallon day tank 305-10 10 gallon day tank 305-15 15 gallon day tank 305-25 25 gallon day tank PIPE STANDS, ADAPTER ONLY (set of 4) — Adapters (only) and frame to elevate day tank from floor. 310 310A 310B 310C 310D 310E 310X 311 10 thru 25 gallon day tanks 50 thru 100 gallon day tanks 150 gallon day tank 200 thru 275 gallon day tanks 300 gallon day tank All other sizes—specify day tank size FILTER MINDER — A differential pressure instrument used to monitor and report the working efficiency of a fuel filtering system. If low or high pressure differential is sensed, an alarm circuit is activated. (Installed or ships loose if filter ships loose.) PRIMING TEE — for easy system startup and pump system re-priming. 312 312A 312B 312C 312D 1/2” NPT 1” NPT 1-1/2” NPT 2” NPT The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-15 MECHANICAL OPTIONS Option Code Description COMPOUND GAUGE, PRESSURE/VACUUM — for inline monitoring pressure normally on the immediate pump outlet (pressure side) or for inline monitoring of vacuum normally on the immediate pump inlet (suction side). 313 313-2 2” Dial 313-4 4” Dial—Glycerin Filled 314-PS-05 314-PS-10 314-PS-15 314-PS-20 2” Dial for Pump Sets with 1/2” Plumbing 2” Dial for Pump Sets with 1” Plumbing 2” Dial for Pump Sets with 1 1/2” Plumbing 2” Dial for Pump Sets with 2” Plumbing FUEL LINE STRAINER — In-line strainers are normally located before pumps, meter, and other devices to filter debris from flowing into and damaging equipment. Strainer baskets are removable for cleaning & replacement. 314 314-YA 314-YB 314-YC 314-YD Y-Type Strainers 1/2” NPT, 20 Mesh 1” NPT, 20 Mesh 1-1/2” NPT, 40 Mesh 2” NPT, 40 Mesh Vertical Strainers 314-KB1 1” NPT, 100 Mesh—Single 314-KB2 1” NPT, 40 Mesh—Duplex 314-KC2 1-1/2” NPT, 40 Mesh—Duplex 315 FUEL FILTER 315SGL SINGLE—1” NPT 60 Mesh, 40 sq. in. element surface loading area for long life between cleanings. (Ships loose—Wt: 6 lbs) 315DPX DUPLEX — Two Option ##315 fuel filters connected in parallel with two 3-way valves for isolation or tandem operation. (Ships loose—18 lbs) 315FLT REPLACEMENT FILTER & GASKET For options #315SGL and #315DPX (Ships loose—Wt: 3 lbs) 318 FUEL FILTER / WATER SEPARATOR (TYPE-F) 318SGL SINGLE—A filter and housing to effectively remove water and solids from fuel. 1-1/2” NPT, U/L approved up to 50 psi. Specify a 3, 10 or 25 micron filter. (Ships loose—41 lbs) 318DPX DUPLEX — Two Option ##318 fuel filters connected in parallel with two 3-way valves for isolation or tandem operation. (Ships loose—85 lbs) 318FLT REPLACEMENT FILTER & GASKET For option #318SGL And #318DPX (Ships loose—Wt: 3 lbs) The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-16 MECHANICAL OPTIONS Option Code Description FUEL FILTER / WATER SEPARATOR (TYPE-R) — A filter and housing to effectively remove water and solids from fuel. U/L approved up to 50 psi. (Available in 2, 10, 25, and 30 micron filters—please specify.) 319 319SGL Single Separator Unit — Performance - 180 gal / hr (Ships loose—Wt: 10 lbs) 319DPX Duplex Manifold Unit —- Performance - 360 gal / hr (Ships loose—Wt: 26 lbs) 319TRI Tri-Manifold Unit — Performance - 540 gal / hr (Ships loose—Wt: 39 lbs) VENT CAP —- Mushroom 320 320A 2” NPT (Ships loose — Wt: 2 lbs) 320B 3” NPT (Ships loose — Wt: 4 lbs) 320C 4” NPT (Ships loose — Wt: 5 lbs) VENT CAP, PRESSURE RELIEF-U/L LISTED 321 321A 321B 321C 321D 2” NPT (Ships loose — Wt: 5 lbs) 3” NPT (Ships loose — Wt: 10 lbs) 4” NPT (Ships loose — Wt: 15 lbs) 6” NPT (Ships loose — Wt: 25 lbs) VENT KIT, SINGLE WALL - A tank venting system that includes one working vent cap and one emergency pressure relief cap. 322 322A 322B 322C 322D 2” NPT (Ships loose — Wt: 4 lbs) 3” NPT (Ships loose — Wt: 5 lbs) 4” NPT (Ships loose — Wt: 7 lbs) 6” NPT (Ships loose — Wt: 15 lbs) VENT KIT, DOUBLE WALL — A tank venting system that includes two working vent caps and two emergency pressure relief caps. 323 323A 323B 323C 323D 2” NPT (Ships loose — Wt: 10 lbs) 3” NPT (Ships loose — Wt: 19 lbs) 4” NPT (Ships loose — Wt: 27 lbs) 6” NPT (Ships loose — Wt: 46 lbs) 324 VENT OVERFLOW DETECTOR — A sensor to detect any fuel overfilling into the vent. A red alarm light on the tank control panel is activated and pump motor(s) are shut down, (15 amp). 326 SIGHT GLASS - Glass tube with two hand valves, guard included The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-17 MECHANICAL OPTIONS Option Code Description EXTRA PIPE CONNECTION / PORTS — Hole and NPT weld flange for customer specified additional plumbing and control port. The Double Wall version (Option 333x) is piped through the double wall containment area. 330 & 333 STANDARD SIZES OOPTION CODE NPT SIZE 334 1/2” 1” SINGLE WALL (Opt 330x) 330A 330B 1-1/2” 2” 330C 330D 3” 330E 4” 6” ADDITIONAL SIZES OOPTION CODE NPT SIZE DOUBLE WALL (Opt 333x) 333A 1/8” 1/4” SINGLE WALL (Opt 330x) 330H 330J 333B 3/8” 3/4” 330K 330L 333C 1-1/4” 330M 330F 2-1/2” 330N 330G 5” 330P DOUBLE WALL (Opt 333x) 333K DAY TANK COVER—A NEMA-1 Enclosure for Day Tanks to provide NEMA-1 protection for pump/motor system and related control components. 334-1 SINGLE enclosure for one pump/motor set. (This cover is standard equipment for Standard, Trim, and Manual Day Tanks with single pump and motor set.) 334-2 DUPLEX enclosure for two pump/motor set. (This cover is standard equipment for duplex supply pumps and motors with Options #s 427, 427A, or 427B. 334-3 TRIPLEX enclosure for three pump/motor set. 334-4 QUAD enclosure for four pump/motor set. 335 WEATHERPROOF DAY TANK COVER—A NEMA-3R Enclosure for Day Tanks to provide protection against normal weather elements for pump/motor system and related control components. 335-1 SINGLE enclosure for one pump/motor set. 335-2 DUPLEX enclosure for two pump/motor set. 335-3 TRIPLEX enclosure for three pump/motor set. 336-4 QUAD enclosure for four pump/motor set. STEEL WEATHERPROOFING OF RUPTURE BASIN — A NEMA 3R rated enclosure of the 335RB rupture basin containment area to provide outdoor protection against normal weather elements. A viewing window is covered with sealed plexi glass and all openings are pipedthrough. 335RB/01 10 - 25 Gallon Tank 335RB/02 50 - 75 Gallon Tank 335RB/03 100 - 150 Gallon Tank 335RB/04 200 - 300 Gallon Tank 335RB/05 400 - 600 Gallon Tank 335RB/06 700 - 800 Gallon Tank 335RB/07 900 - 1000 Gallon Tank The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-18 MECHANICAL OPTIONS Description Option Code 465 ENCLOSED INDUSTRIAL CONTROL PANEL — A heavy gauge steel enclosure that meets U/L requirements (Label #508). Only U/L Listed components are used within. These components the make up various day tank accessories include: contactors, relays, sockets, lights, and switches, even the wire and connectors. ENCLOSURE for “Closed Design” Pump Sets (PYPS2000 Series) A NEMA-1 or NEMA-3R (see below) enclosure featuring: Heavy galvannealed steel, A lockable door with a continuous hinge (may be complimented with a optional door interlock system - see Option 339 below), Protected vent openings for adequate ventilation 338 PUMP SET MODEL # NEMA RATING PUMP CONFIG. 338A PYPS2100 338B PYPS2200 1 Single Pump 1 Duplex Pump 338C PYPS2100 338D PYPS2200 3R Single Pump 3R Duplex Pump 339 DOOR INTERLOCK w/CIRCUIT BREAKER— Used to require power to pump set to be shut down before door may be opened. Circuit breaker sized to motor. 339-1-10 339-1-15 339-1-20 339-1-30 Single pole, 1ph, A/C - 10 Amp. Single pole, 1ph, A/C - 15 Amp. Single pole, 1ph, A/C - 20 Amp. Single pole, 1ph, A/C - 30 Amp. 339-2-15 Double pole, 1ph, A/C - 10 Amp. 339-3-15A 3-Phase, A/C, 230vac—15 Amp. 339-3-15B 3-Phase, A/C, 460vac—15 Amp. 339-DC All D/C motors - Up to 30 Amp. 340 DRAIN PETCOCK 0VALVE— A gate valve that replaces threaded plug in end at bottom of tank 340A — 1/2” 340B — 1” 340D —- 2” 340K — 3/8” 340L — 3/4” The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-19 MECHANICAL OPTIONS Option Code 341 Description DRAIN, PIPED THROUGH SECONDARY CONTAINMENT AREA — The plumbing necessary to drain the inner tank through to the outside of a secondary containment area. Rupture Basin secondary containment 341RBA — 1/2” 341RBK — 3/8” 341RBB — 1” 341RBL — 3/4” 341RBD —- 2” 343 345 SIPHON DRAIN ASSEMBLY— The plumbing to siphon-drain most fuel from a day tank . Includes a Quarter-Turn Valve. DRAIN, NOMINAL 10 GPM—Includes a lockable 1/4-turn manual valve 345 Single Wall 345DW Double Wall (Piped Through) 345RB Rupture Basin (Piped Through) 350 DRAIN, EMERGENCY FOR REMOTE ACTUATION - An "Quick" drain at nominal 10gpm located at the bottom of a all tank. When a customer supplied signal is received opening a solenoid valve, the fuel is gravity drained from day tank. Light on control panel illuminates and pump-motor disconnects. 350 Single Wall 350DW Double Wall (Piped Through) 350RB Rupture Basin (Piped Through) 352 OIL COOLER — mounted on day tank for cooling hot fuel returned from engine. Low noise level. Installed on Day Tank 352 Standard Oil Cooler Motor 352WP Standard Oil Cooler Motor with Weatherproof Motor Ship loose as part 352SL Standard Oil Cooler Motor 352WPSL Standard Oil Cooler Motor with Weatherproof Motor 353 TEMPERATURE SWITCH — A switch, set at 130 degrees, to automatically control on/off of oil cooler motor. The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-20 MECHANICAL OPTIONS Option Code Description HIGH TEMPERATURE RETURN THERMOSTATIC VALVE — 1” A return fuel valve that will close if temperature rises above a preset temperature. 354 O 354-05-90 90 Close—1/2” Return Plumbing O 354-10-90 90 Close—1” Return Plumbing O 354-10-160 160 Close—1” Return Plumbing CHECK VALVE — installed on pump intake to prevent loss of pump prime 355 355A 1/2” NPT 355B 1” NPT 355C 1 1/2” NPT 360 SOLENOID VALVE, Normally Closed (N/C) — Installed on tank inlet to prevent tank flooding and for other special applications. 360A-120 360B-120 360C-120 360D-120 120vac Systems — ½” 120vac Systems — 1” 120vac Systems — 1½” 120vac Systems — 2” (up to 4 gpm fuel flow) (up to 10 gpm fuel flow) (up to 23 gpm fuel flow) (up to 65 gpm fuel flow) 360A-230 360B-230 360C-230 360D-230 230vac Systems — ½” 230vac Systems — 1” 230vac Systems — 1½” 230vac Systems — 2” (up to 4 gpm fuel flow) (up to 10 gpm fuel flow) (up to 23 gpm fuel flow) (up to 65 gpm fuel flow) 360A-D12 360B-D12 360C-D12 360D-D12 12vdc Systems — ½” 12vdc Systems — 1” 12vdc Systems — 1½” 12vdc Systems — 2” (up to 4 gpm fuel flow) (up to 10 gpm fuel flow) (up to 23 gpm fuel flow) (up to 65 gpm fuel flow) 360A-D24 360B-D24 360C-D24 360D-D24 24vdc Systems — ½” 24vdc Systems — 1” 24vdc Systems — 1½” 24vdc Systems — 2” (up to 4 gpm fuel flow) (up to 10 gpm fuel flow) (up to 23 gpm fuel flow) (up to 65 gpm fuel flow) 361 361D-120 361D-230 361D-D12 361D-D24 Normally for 1/2”, 1”, and 1-1/2” Solenoid Valves Normally for 2” Solenoid Valves SOLENOID VALVE, 2”, Normally Open (N/O) - for Remote Fill Panel (options #226 and #230) and other applications. 120vac Systems 230vac Systems 12vdc Systems 24vdc Systems The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-21 MECHANICAL OPTIONS Option Code Description 362 SOLENOID VALVE, Normally Open (N/O) — tank installed for Option #213 and other applications where inlet fuel control is required. 362/120-A 362/120-B 362/120-C 362/120-D 120vac Systems — 1/2” (up to 4 gpm fuel flow) 120vac Systems — 1” (up to 10 gpm fuel flow) 120vac Systems — 1 1/2” (up to 23 gpm fuel flow) 120vac Systems — 2” (up to 65 gpm fuel flow) 362/230-A 362/230-B 362/230-C 362/230-D 230vac Systems — 1/2” (up to 4 gpm fuel flow) 230vac Systems — 1” (up to 10 gpm fuel flow) 230vac Systems — 1 1/2” (up to 23 gpm fuel flow) 230vac Systems — 2” (up to 65 gpm fuel flow) 362/D12-A 362/D12-B 362/D12-C 362/D12-D 12vdc Systems — 1/2” (up to 4 gpm fuel flow) 12vdc Systems — 1” (up to 10 gpm fuel flow) 12vdc Systems — 1 1/2” (up to 23 gpm fuel flow) 12vdc Systems — 2” (up to 65 gpm fuel flow) 362/D24-A 362/D24-B 362/D24-C 362/D24-D 24vdc Systems — 1/2” (up to 4 gpm fuel flow) 24vdc Systems — 1” (up to 10 gpm fuel flow) 24vdc Systems — 1 1/2” (up to 23 gpm fuel flow) 24vdc Systems — 2” (up to 65 gpm fuel flow) Normally for 1/2”, 1”, and 1-1/2” Solenoid Valves Normally for 2”, A/C Solenoid Valves, and 1”, 1-1/2”, & 2” D/C Solenoid Valves 364 SOLENOID VALVE w/MANUAL OVERRIDE, Normally Closed (N/C) 364/120-A 364/120-B 364/120-C 364/120-D 120vac Systems — 1/2” (up to 4 gpm fuel flow) 120vac Systems — 1” (up to 10 gpm fuel flow) 120vac Systems — 1 1/2” (up to 23 gpm fuel flow) 120vac Systems — 2” (up to 65 gpm fuel flow) 364/230-A 364/230-B 364/230-C 364/230-D 230vac Systems — 1/2” (up to 4 gpm fuel flow) 230vac Systems — 1” (up to 10 gpm fuel flow) 230vac Systems — 1 1/2” (up to 23 gpm fuel flow) 230vac Systems — 2” (up to 65 gpm fuel flow) 364/D12-A 364/D12-B 364/D12-C 364/D12-D 12vdc Systems — 1/2” (up to 4 gpm fuel flow) 12vdc Systems — 1” (up to 10 gpm fuel flow) 12vdc Systems — 1 1/2” (up to 23 gpm fuel flow) 12vdc Systems — 2” (up to 65 gpm fuel flow) 364/D24-A 364/D24-B 364/D24-C 364/D24-D 24vdc Systems — 1/2” (up to 4 gpm fuel flow) 24vdc Systems — 1” (up to 10 gpm fuel flow) 24vdc Systems — 1 1/2” (up to 23 gpm fuel flow) 24vdc Systems — 2” (up to 65 gpm fuel flow) Normally for 1/2”, 1”, and 1-1/2” Solenoid Valves Except 24 vdc The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-22 MECHANICAL OPTIONS Option Code Description MOTORIZED BALL VALVE — for Remote Fill Panel (options #226 and #230) and other applications. 367 367/120-D 120 vac Systems — 2” NPT 367/120-E 120 vac Systems — 3” NPT 367/230-D 230 vac Systems — 2” NPT 367/230-E 230 vac Systems — 3” NPT 367/D12-D 12 vdc Systems — 2” NPT 367/D12-E 12 vdc Systems — 3” NPT 367/D24-D 24 vdc Systems — 2” NPT 367/D24-E 24 vdc Systems — 3” NPT 367ALS AUXILIARY LIMIT SWITCH — for all #367 Motorized Ball Valves MANUAL BALL VALVE, 1/4 Turn — installed on pump sets for component isolation. 369 369A 369B 369C 369D 1/2” NPT 1” NPT 1 1/2” NPT 2” NPT MANUAL BALL VALVE, 1/4 Turn — Manual cut off valve installed in fuel inlet that is primarily used for gravity-fed day tanks. 370 370A 370B 370C 370D 1/2” NPT (Ships loose — Wt: 2 lbs) 1” NPT (Ships loose — Wt: 3 lbs) 1 1/2” NPT (Ships loose — Wt: 6 lbs) 2” NPT (Ships loose — Wt: 14 lbs) FLOW METER — An in-line meter to measure amount of fuel flow from main storage tank to day tank, 1” NPT 371 371A .3 to 3 GPM (Ships loose—Wt. 4 lbs) 371B 3 to 30 GPM (Ships loose—Wt. 5 lbs) 372 FLOW SWITCH — An inline switch to detect “no fuel” In fuel line. Several events are possible, including pump and motor shut down and/or sounding an alarm. Closing the switch can be delayed, see option #373 below. (10 watts) 373 TIME DELAY RELAY— for option #372 with reset pump and motor shut down (10 amp) The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-23 MECHANICAL OPTIONS Option Code Description 374 FUSE-LINK VALVE (for fire safety) - Automatically closes fuel line when ambient temperature reaches 165º F—1” NPT. (Ships loose—Wt. 8 lbs) 375 FOOT VALVE — For installation in a main storage tank to prevent loss of pump prime, 1” NPT (Ships loose—Wt. 6 lbs) 376 FOOT VALVE — Installed in day tank to prevent loss of return pump prime and engine suction, 1” NPT IN-LINE PRESSURE RELIEF BYPASS VALVE — Re-routes fuel when line pressure reaches that shown below for pipe size. 379 379A 379B 379C 379D 1” @ 50 psi — 20 gpm max. 1.5” @ 50 psi — 40 gpm max. 2” @ 50 psi — 120 gpm max. 2” @ 75 psi — 120 gpm max. 380 PRESSURE RELIEF VALVE - installed on motor driven pump. Internal pressure relief 381 FLAME ARRESTOR - to protect from fire or explosion from exterior ignition source. (Ships loose — Wt. 4 lbs) RUPTURE BASIN — Open top secondary containment tank, U/L Listed. 385/xx Single Wall—Standard and Manual Day Tanks, 150% Containment 386/xx Single Wall—Standard and Manual Day Tanks, 200% Containment 385DW/xx Double Wall—Standard and Manual Day Tanks, 200% Containment Refer to the table at the top of the next page to determine which option code fits your day tank. Single Wall—Trim Day Tanks, 150% Containment 385TRM/01 385TRM/02 385TRM/03 385TRM/04 385TRM/05 385TRM/06 385TRM/07 385TRM/08 10 Gallon (PY10T) 15 Gallon (PY15T) 25 Gallon (PY25T) 50 Gallon (PY50T) 60 Gallon (PY60T) 75 Gallon (PY75T) 100 Gallon (PY100T) 150 Gallon (PY150T) The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-24 MECHANICAL OPTIONS Description Option Code RUPTURE BASIN — Open top secondary containment tank, U/L Listed. 150% RUPTURE BASINS TANK SIZE (U.S. GAL) 200% RUPTURE BASINS 200% RUPTURE BASINS for DOUBLE WALL TANKS WEIGHT (Lbs) Standard & Manual Day Tanks WEIGHT (Lbs) Trim Day Tanks OPTION CODE (200%) WEIGHT (Lbs) Standard & Manual Day Tanks) WEIGHT (Lbs) Trim Day Tanks 5-10 385/01 76 58 386/01 87 77 385DW/01 15 385/02 86 N/A. 386/02 87 N/A 385DW/02 25 385/03 93 123 386/03 108 105 385DW/03 50 385/04 161 135 386/04 169 169 385DW/04 60 385/05 172 165 386/05 183 183 385DW/05 75 385/06 198 182 386/06 207 210 385DW/06 100 385/07 223 206 386/07 249 247 385DW/07 150 385/08 274 386/08 325 385DW/08 200 385/09 396 386/09 457 385DW/09 275 385/10 468 386/10 531 385DW/10 300 385/11 485 386/11 537 385DW/11 400 385/12 537 386/12 603 385DW/12 500 385/13 640 386/13 652 600 385/14 718 386/14 694 385DW/14 700 385/15 785 386/15 743 385DW/15 800 385/16 854 386/16 791 385DW/16 900 385/17 911 386/17 840 385/DW17 1000 385/18 992 386/18 888 385DW/18 N/A N/A OPTION CODE (D/W 200%) 385DW/13 WEIGHT (Same As 200% Rupture Basins Shown To The Left) OPTION CODE (150%) 395 LEAK DETECTOR FOR RUPTURE BASINS OF TANKS WITH PUMP and MOTOR - A sensor within the Rupture Basin containment area that upon detection of a leak will turn on a red alarm light on control panel and will shut down pump motor. Includes dry terminal contacts for connection of customer supplied device up to 15 amp. 395M LEAK DETECTOR FOR RUPTURE BASINS OF MANUAL OR SUB-BASE TANKS — A sensor within the Rupture Basin containment area that upon detection of a leak will turn on a red alarm light on control panel. Includes dry terminal contacts for connection of customer supplied device up to 15 amp. The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-25 MECHANICAL OPTIONS Option Code Description REMOTE PUMPING UNIT (RPU) — A Weatherproof (NEMA 3R) base and enclosure used to re-locate the pumping system (up tyo and including duplexed 23-gpm pumps) from a day tank to a point between the day tank and the main storage tank to extend the distance from a main storage tank. Another application for an RPU is in a Remote Fill Panel configuration. 397 The SINGLE Pumping System includes a 1/3 HP, 115 VAC, 1-Phase, 60 Hz motor and a 2 GPM bronze pump (standard pump and motor) that normally would be located on the day tank top. The DUPLEX Pumping System includes two standard pumps and motors. Each pump of a multi-pump system may be assigned either supply or return duty or mixed. Optionally, pumps and motors other than the standard configurations described above may be specified as replacements of the standard ones. Optional check and solenoid valves, if attached to fuel inlet, may also be located on the RPU platform. Note — a Pump Set must be specified if (1) the size of the largest pump exceeds the dimensios of a 23 gpm pump, (2) plumbing is greater than that which can be easily contained within the cover, oe (3) one or more other accessories, such as: fuel filter, strainers, flow switches and meters, gauges, isolation and by-pass valves, etc. are to be included. (see Pump Set section of this catalog.) 24” wide x 12” deep—For ONE 2 gpm pump only 397-12A SINGLE Remote Pump Unit Base & Cover 24” wide x 18” deep—For up to 10 gpm pumps 397-18A 397-18B 397-18C 397-18D SINGLE Remote Pump Unit Base & Cover DUPLEX Remote Pump Unit Base & Cover Three Remote Pump Unit Base & Cover Four Remote Pump Unit Base & Cover 24” wide x 24” deep—For up to 23 gpm pumps 397-24A 397-24B 397-24C 397-24D 398 399 SINGLE Remote Pump Unit Base & Cover DUPLEX Remote Pump Unit Base & Cover Three Remote Pump Unit Base & Cover Four Remote Pump Unit Base & Cover 397-18B Duplex RPU (Weatherproof Cover Removed) REMOTE READING LEVEL GAUGE — 12 and 24vdc - for remote monitoring of fuel level up to 300’ max. distance. (Does Not include level Gauge. For tanks up to 48” High Max). REVERSE FLOW CONTROLLER — to pump fuel from Day Tank back to main storage tank. Requires separate pump and motor (specify size). Includes float switch and pipe stems. (Pumps and Motors must be ordered separately.) OPTION CODE BY NPT PIPE SIZE 1/2” 1” 1 1/2” 2” CONTROLS and PLUMBING FOR ... Single reverse flow pump and motor 399-1-05 399-1-10 399-1-15 399-1-20 Two reverse flow pumps and motors Duplex reverse flow pumps and motors with automatic switching of each set into lead starting position Duplex reverse flow pumps and motors with manual switching of each set into lead starting position 399-2-05 399-2-10 399-2-15 399-2-20 399A-05 399A-10 399A-15 399A-20 399B-05 399B-10 399B-15 399B-20 The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-26 PUMPS Option Code Standard Pressure Relief Description Flow Rate (GPM) Port Size Minimum Pipe Size Minimum Motor Size (HP) Single P/M Duplex P/M OBDORFER BRONZE GEAR PUMPS * 400 402 403 Add Option #380 401 404 405 BRONZE PUMP 8 1/2” 1/2 1/2” 1” BRONZE PUMP 4 3/8” 1/3 1/2” 1” BRONZE PUMP 2 3/8” 1/3 1/2” 1” BRONZE PUMP 10 1/2” 3/4 1” 1 1/2” BRONZE PUMP 23 1” 1 1” 1 1/2” 1 1/2” 2” 2 HP @ 1200RPM TUTHILL CAST IRON PUMPS * n/a BRONZE PUMP 40 1 1/4” PCI03 PCI03R CAST IRON PUMP 3 1/2” 1/3 1/2” 1” PCI06 PCI06R CAST IRON PUMP 6 1/2” 1/2 1/2” 1” PCI13 PCI13R CAST IRON PUMP 13 1” 1 1/2” 1 1/2” PCI15 PCI15R CAST IRON PUMP 15 1 1/4” 1 1/2 1” 2” PCI25 CALL CAST IRON PUMP 25 1 1/2” 3 1” 2” PCI62 CALL CAST IRON PUMP 62 1 1/2” 5 1 1/2” 2” HAND PUMPS Option Code Description 461 HAND PUMP, PISTON TYPE — 5 strokes per gallon; Equipped with TFE Piston cups; Operating temperature of -25° to 200°F; Dual Action—Dispenses on each stroke; and, Self-priming w/up to 20 ft of lift. Hand pump check valve and motor pump check valve included. 462 HAND PUMP, ROTARY - High flow (10 rotations per gallon; 2 per liter); All cast -iron housing with stainless steel shaft & strainer; Malleable iron pump handle with rotating grip for ease of use; Self-adjusting spring-loaded carbon vanes give smooth operation; Internal check valve allows immediate dispensing; Built-in stainless steel strainer. Hand pump check valve and motor pump check valve included. The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-27 MOTORS—A/C OPTION CODE HP VOLTAGE THERM. CYCLE PROT. PH 414 1/3 115 1 60 424 1/3 115 1 425 1/3 115 426 1/3 428 MOTOR STARTERS COMMENT OPT. CODE REQ / OPT YES 443A Optional * (Pryco’s Standard Motor) 60 YES 443A Optional * T.E.F.C. 1 60 YES 443A Optional * Explosion Proof 110 1 50 YES 443A Optional * 1/3 230 1 60 YES 443E Optional * 429 1/3 220 1 50 YES 443E Optional * 433A 433B 1/3 230 460 3 60 NO 442A 442E Required 444 1/2 115 1 60 YES 443B Optional * 445 1/2 115 1 60 YES 443B Optional * T.E.F.C. 446 1/2 115 1 60 YES 443B Optional * Explosion Proof 447 1/2 110 1 50 YES 443B Optional * 448 1/2 230 1 60 YES 443F Optional * 449 1/2 220 1 50 YES 443F Optional * 451 1/2 230 3 60 NO 442B Required T.E.F.C., Includes Starter 452 1/2 460 3 60 NO 442F Required Includes Motor Starter 454 1/2 230 3 60 NO 442B Required Includes Motor Starter 434 3/4 115 1 60 YES 443C Optional * Explosion Proof 435A 435B 3/4 230 460 3 60 NO 442C 442G Required Exp. Proof, Includes Starter 455 3/4 115 1 60 YES 443C Optional * 456A 456B 3/4 230 460 3 60 NO 442C 442G Required Includes Motor Starter 436 1 115 1 60 YES 443D Optional * Explosion Proof 437A 437B 1 230 460 3 60 NO 442D 442H Required Explosion Proof Includes Motor Starter 457 1 115 1 60 YES 442D Optional * 458A 458B 1 230 460 3 60 NO 442D 442H Required Includes Motor Starter 459A 459B 2 230 460 3 60 NO 442L Required T.E.F.C. Includes Motor Starter Includes Motor Starter OTHER 463 STANDARD PUMP and MOTOR — A coupled 2 GPM bronze pump (Option # 402) and a 1/3 HP, 120 vac, 1 PH, 60 Hz motor (Option #414) purchased separately * All single phase A?C motors are Thermal requiring starter.notification. The content herein isProtected subject to changenowithout P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-28 MOTORS & ACCESSORIES MOTORS — D/C VOLTAGE MOTOR STARTERS 1/4 HP 1/2 HP OPT. CODE OPT. CODE 12 410 440 24-28 411 441 OPTION—443x MOTOR STARTER - 1 PH, includes control transformer and heater sized according to motor requirement. OPTION—442x MOTOR STARTER - 3 PH, 130 watt control transformer and heater. Motor Starters and Control Transformers are included with all 3Phase motors. THREE PHASE SINGLE PHASE OPTION HP VOLT OPTION HP VOLT 442A 1/3 230 443A 1/3 115 442B 1/2 230 443B 1/2 115 442C 3/4 230 443C 3/4 115 442D 1 230 443D 1 115 442E 1/3 460 443E 1/3 230 442F 1/2 460 443F 1/2 230 442G 3/4 460 443G 1-1/2 to 2 115 442H 1 460 443H 3/4 230 442J 1-1/2 460 443J 1 230 442K 1-1/2 460 443K 1-1/2 220 50Hz 442L 2 230/460 443L 3/4 220 50Hz 442M 5 460 443M 5 208/230 DUPLEX PUMPING SYSTEM ASSEMBLIES CONTROLLER DUPLEX OPTION DESCRIPTION FLOAT SWITCH FCM OPTION # 700 PLC OPTION # 800 427 727 See Page-31 827 See Page-32 AUTOMATIC TRANSFER SWITCH — A switching system to automatically alternate each pump-moto into the lead starting position. (At the 82% and lower levels, both will operate.) Includes: Option # x27 (427, 727 or 827}, a pump “RUN-OFF-AUTO” mode selector switch, and one “Pump Running” amber light. 427A 727A See Page-31 827A See Page-32 MANUAL TRANSFER — A switching system to manually alternate each pump-motor into the lead starting position. (At the 82% and lower levels, both will operate.)Includes: Option #x27 (427, 727 or 827}, a manual transfer switch, and a motor run-time meter included for each pump-motor. 427B 727B See Page-31 827B See Page-32 DAY TANKS (STANDARD and TRIM) AND PUMP SETS (INCLUDING REMOTE PUMP UNITS (OPT. #397) (STD) DUPLEX (Second Standard) PUMP and MOTOR ASSEMBLY — A second 2 GPM pump, a Thermal Protected motor (1/3 HP, 115vac, 1PH, 60 Hz) and a second float switch or controller. The first pump-motor (always the “lead”) begins operating at 86% of usable fuel capacity; the second pump-motor (always the “lag”) begins operating to assist the lead pump when fuel drops to 82% of usable fuel capacity. Both pump-motors shut off at 100% capacity. The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-29 FCM & OPTIONS FUEL CONTROL MONITORING (FCM) SYSTEM The FUEL CONTROL and MONITORING (FCM) system, is totally solid state electronic except for a fail-safe critical high fuel level switch. The FCM system uses an ultra-sonic sensor to accurately determine the level of the fuel. It is specially designed for Pryco for this type of environment. Through electronic “action levels” the FCM controls the activities of up to four pumps and motors (Fill or Reverse Flow). It also controls and provides a signal for a full array of external alarms and similar devices based upon predetermined levels. The action levels shown in the table below represent a “normal” setup — changes may be made providing the integrity of a sequence of operation is not violated. STANDARD FEATURES Ultra-Sonic Sensor - 4-20 ma Control Panel Alarm Reset Switch 24vdc Input For Continuous Operation Control Panel Alarm Silence Switch Power Available LED Safety High Switch w/Fill Motor Shut Off System Ready LED High Fuel Level Notification Electronic Fuel Gauge Low Fuel Level Notification HOA Switches “Dry Tank” Prevention Control Panel System Test Switch Secondary Containment Leak Detection ACTION LEVELS (Inches From Top Inside) PY5 PY10 ACTION LEVEL PY15 PY25 PY50 PY60 PY75 PY150 PY200 PY1000 Top Of Tank 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Safety High Level 3.0 3.0 3.0 3.0 3.0 3.0 3.0 High Fuel Level 3.5 3.5 3.5 3.5 3.5 3.5 3.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.5 4.5 4.5 4.5 4.5 4.5 4.5 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.5 6.0 6.0 6.0 6.0 6.0 6.0 6.0 8.0 8.0 8.0 8.0 8.0 10.0 6.5 10.0 10.0 10.0 10.0 10.0 14.0 7.0 12.0 14.0 14.0 14.0 14.0 18.0 8.0 14.0 19.0 26.0 34.0 39.0 44.0 9.5 15.5 20.5 27.5 35.5 40.5 45.5 12.5 18.5 23.5 30.5 38.5 43.5 48.5 Secondary Reverse Flow - ON Primary Reverse Flow - ON [1] Fill Pumps - OFF (100% Full) Reverse Pumps - OFF [1] Primary Fill Pump - ON Secondary Fill Pump - ON Low Fuel Level Critical Low Level [1] Dry Tank Protection Level Empty Tank (0%) [1] [1] If installed The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-30 FCM & OPTIONS The FCM system is designed to allow it to be mounted on a day tank, subbase tank, or a remote pumping unit. It may be off-mounted to a wall unit, etc., provided the sensor is tank mounted. FCM and RELATED OPTIONS Option Code 700 Description FUEL CONTROL AND MONITORING SYSTEM — electronic circuit boards, ultra-sonic sensor, and related components to control and monitor all activities on the fuel system. 706 CRITICAL LOW LEVEL ALARM — Activates red light on control panel, provides signal for remote annunciation and engine shut down (prevents loss of engine fuel prime). 734 734-1 734-2 734-3 734-2 727 COVER—DAY TANK w/FCM, NEMA-1 SINGLE—one pump and motor DUPLEX—two pumps and motors TRIPLEX—three pumps and motors QUAD—four pumps and motors DUPLEX FILL PUMP and MOTOR — (addition to standard pump and motor) secondary “lag” pump/motor system to back-up primary “lead” pump/motor. Normally the lead pump/motor begins operation at 86% usable fuel capacity; the lag system begins at 82%. Both systems turn off at 100% capacity. 727A DUPLEX FILL PUMP and MOTOR w/AUTOMATIC ALTERNATING LEAD/LAG — Same as Option 727 with a switch to automatically alternate each pump/motor into the lead starting position. 773 PUMP(s) FAIL DETECTION w/AUTOMATIC and MANUAL RESET — Includes: the control panel switch, an in-line flow switch, and other required items necessary to detect, report, and reset a “no fuel in line” condition (one per pump). A flow switch, option #372, is required. 780 FCM POWER SUPPLY PROTECTION — Line Conditioner and noise suppression with battery backup to protect FCM electronics and circuits from damaging “brown outs” and spikes. 799 REVERSE FLOW CONTROLS for OPTIONAL PUMP and MOTOR — Controls and piping necessary for a reverse flow single pump/motor (sold separately) to pump fuel back to main storage tank to prevent overfill. This system begins operation at a level above the fill pump(s) normal turn-off point. 799A DUPLEX REVERSE FLOW PUMP and MOTOR w/AUTOMATIC ALTERNATING LEAD/LAG — Two sets of controls and piping necessary for two reverse flow pumps/motors to pump fuel back to main storage tank to prevent overfill. (The pumps and motors are sold separately.) The “lead” system begins operation at a level above the fill pump(s) turn-off point – the “lag” system begins at a level above the lead system (provides assistance and backup). The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-31 EVOLUTION PLC & OPTIONS Option Code 800 Description EVOLUTION PLC SYSTEM — Tank mounted, Programmable Logic Controller (PLC) based system designed to control and monitor the activities of up to four pumps and motors. Standard Features include: * * * * * * * 805 120/240 VAC Input Voltage Ultra-Sonic Sensor Color LED Touchscreen HMI Graphic Fuel Gauge Notification Power Available LED HOA Switches Historical Log * * * * * * * Critical High Switch w/Fill Motor Shut Off High Fuel Level Notification Low Fuel Level Notification Critical Low Level Secondary Containment Leak Detection Discrete N.O. Contacts For All Alarms Control Panel Alarm Silence Switch MEMORY MODULE— for program upgrade as necessary 805-32 32K of Memory 805-64 64K of Memory 810 COMMUNICATIONS MODULE for PLC — Directs Logic Controller output downstream to in-house building management systems 810-485 810-ETH RS485/RS232 Modbus (distance rating: RS232—50 Feet, RS485—656 feet) Ethernet 812 BLACK-BOX CONVERTER — RS485 to RS232 (Used only if customer does not have RS485 connection.) 815 ANALOG MODULE — (2 each) 4-20 MA Output 820 CABLES 820-DB9-06 Cable w/DB9 Male/Female connectors—6 feet 820-SHL-12 Cable, Bulk Shielded, Low Capacity, 4 conductor—12 feet 827 DUPLEX SUPPLY SYSTEM (PLC CONTROLLED) — additional secondary controls, piping and standard 2 GPM pump & 1/3 HP motor “lag” system to back-up primary “lead” pump/motor. Normally the lead pump/motor begins operation at 86% usable fuel capacity; the lag system begins at 82%. Both systems turn off at 100% capacity. 827A DUPLEX SUPPLY SYSTEM w/AUTOMATIC LEAD/LAG PUMP SWAP (PLC CONTROLLED) — Same as Option 827 plus HOA switching capability to automatically alternate each pump/motor into the lead starting position. 827B DUPLEX SUPPLY SYSTEM w/MANUAL LEAD/LAG PUMP SWAP (PLC CONTROLLED) — Same as Option 827 plus switching capability to manually alternate each pump/motor into the lead starting position. 830 SOFTWARE — WindSRV for in-house building management system’s PC drivers EVOLUTION OPTIONS CONTINUED NEXT PAGE The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-32 EVOLUTION PLC & OPTIONS Option Code Description COVER (DAY TANK w/PLC)—NEMA-1 ENCLOSURE for PLC TANK MOUNTED SYSTEMS 834 834-1 SINGLE pump and motor (replaces the single pump/motor cover that is standard equipment for all day tanks). 834-2 DUPLEX (2) pumps, motors, and control components. This cover is standard equipment for duplex supply pumps & motors with Options 827, 827A, or 827B. 834-3 TRIPLEX (3) pumps, motors, and control components. 834-4 QUAD (4) pumps, motors, and control components. 835 WEATHERPROOFING For OPTION 834 SERIES COVERS - A NEMA 3R rated enclosure to provide protection against normal weather elements. The control panel viewing area is covered with sealed plexi glass window and door, and all openings are piped-through. Inside, a pan provides protection from flooding. REMOTE OPERATOR INTERFACE (HMI) - requires wall mounting box 850 850-W10 Color LCD Touch Screen—10.4” 850-W12 Color LCD Touch Screen—12.1” ENCLOSURE, WALL MOUNT— for locating all PLC components, except the ultrasonic sensor, from tank mount 870 870-1620-1 870-2020-3R 870-1616-4 870-1620-4S NEMA 1 enclosure (16” x 20” x 8.75”) NEMA 3R enclosure (20” x 20” x 8”) NEMA 4-12 enclosure (16” x 16” x 8”) NEMA 4-12 enclosure w/security window (16” x 20” x 8”) 873 PUMP FAIL DETECTION — w/manual reset (requires an inline Flow Switch to detect “no fuel” In fuel line, Option #372). 899-1 PLC CONTROLS and PLUMBING (SINGLE) — controls and tank plumbing required for a single reverse flow pump and motor to pump fuel back to main tank. * 899-2 PLC CONTROLS and PLUMBING (DUPLEX) — controls and tank plumbing required for two reverse flow pumps and motors to pump fuel back to main tank. * 899A PLC CONTROLS and PLUMBING for DUPLEX REVERSE FLOW SYSTEM w/ AUTOMATIC LEAD/LAG PUMP SWAP — Same as Option 899-2 with a HOA switch to automatically alternate each pump/motor into the lead starting position.* 899B PLC CONTROLS and PLUMBING for DUPLEX REVERSE FLOW SYSTEM w/ MANUAL LEAD/LAG PUMP SWAP — Same as Option 899-2 with a switch to manually alternate each pump/motor into the lead starting position. * * Pumps and Motors must be ordered separately for Options 899-1, 899-2 899A and 899B The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-33 BATTERY BOXES & FRAMES BATTERY FRAMES BATTERY BOXES Hinged, lockable, weatherproof enclosure with handles Option Code Formed 7-gauge; Standard frames are 4” high, Painted flat black or industrial color of choice. Option Code SIZE BB01 12” W x 23” L x 12” H (1 - 4D or 1 8D) SIZE BF01 BB02 12” W x 44” L x 12” H (2 - 4D or 2 - 8D) STANDARD BATTERY FRAME — 10” x 22” for one Group 4D Battery BFS01 BB04 12” W x 44” L x 12” H w/HEAT PANEL and THERMOSTAT - 100 watt, SEISMIC BATTERY FRAME — 10” x 22” for one Group 4D Battery BF02 STANDARD BATTERY FRAME — 12” x 22” for one Group 8D Battery BSF02 SEISMIC BATTERY FRAME — 12” x 22” for one Group 8D Battery BF03 STANDARD BATTERY FRAME — 10” x 44” for two Group 4D Battery BFS03 SEISMIC BATTERY FRAME — 10” x 44” for two Group 4D Battery BF04 STANDARD BATTERY FRAME — 12” x 44” for two Group 8D Battery BSF04 SEISMIC BATTERY FRAME — 12” x 44” for two Group 8D Battery Shown here are a few of the more common asked for sizes and styles — We will design and build Battery Boxes and Frames, both basic and seismic to your specification and battery types. Battery Box Standard Battery Frame Seismic Battery Frame—Floor & Battery Bolt-Down The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-34 3rd & Garvey Streets P.O.Box 108 Mechanicsburg, IL 62545 Telephone — 217-364/4467 Fax — 217-364/4494 Email — [email protected] The content herein is subject to change without notification. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364/4467 Fax - 217 / 364/4494 OP-35 REMOTE PUMPING UNIT Option #397-12A Single Remote Pumping Unit (with Standard Pump & Motor) The purpose of a Remote Pumping Unit is to relocate the pump/motor away from the day tank or sub-base tank for several reasons, including: Distance between main storage tank and the day/sub-base tank. The suction of all pumps is limited to 18’ of vertical lift or 200’ of horizontal run. Discharge Pressure - Up to 100 psi for all pumps; and, Convenience - fuel supply or return pump/motor(s), in any configuration or size, may be relocated to a Remote Pumping Unit. The remote unit frames are constructed of heavy gauge steel with a removable cover for a NEMA 3R enclosure rating. The standard “single” unit, Option #397-12A, is equipped with our standard pump and motor (a 2GPM bronze pump and a 1/3HP, 115VAC, 1PH, 60HZ, thermal protected motor). The standard “duplex” unit, Option #397-12B, has a second pump/motor set. (Large, customdesigned remote units can be built to your specifications.) Mechanical drawings of Remote Pumping Units are on the following pages. Duplex Remote Pumping Unit Option #397-12B P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-1 PRYCO STANDARD SINGLE REMOTE PUMPING UNIT P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-2 PRYCO STANDARD DUPLEX REMOTE PUMPING UNIT P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-3 PRYCO STANDARD TRIPLEX REMOTE PUMPING UNIT P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-4 DUPLEX PUMPING SYSTEM Pryco’s Duplex Alternating Fuel System (option 427A) is one of our most popular features that we incorporate into a fuel supply system. It solves the problems of a keeping up with fuel consumption by providing a redundant back -up system, and reducing wear and tear on pumps and motors by cycling roles between the two. LEAD/LAG CONCEPT The first time power is applied to the overall system, an alternating switch will place one of the pumps (we’ll refer A 427A Duplex Pumping System That Is Remote to it as physical pump #1) into the priPumping Unit Mounted mary or “LEAD” position. (Physical pump #2 is assigned secondary or “LAG” position). The next time fuel is required, physical pump #2 is switched up into lead position and physical pump #1 falls to secondary duty. These two physical pumps will alternate in and out of lead/lag positions each time fuel controls call for fuel to be pumped into the tank. KEEPING UP WITH FUEL CONSUMPTION Normally, both pumping systems are singularly sized to the demands of the consuming unit (generator, boiler, etc.). If for some reason the consuming unit requires more fuel than the LEAD pump can supply, the LAG pumping system would switch on to assist the LEAD pump until the fuel level reaches a 100% useable fuel capacity level, at which time, both LEAD and LAG pumps are turned off. The normal “ON” fuel level for the LEAD pump is 86% and the level where the assisting LAG pump kicks in is 82% useable fuel capacity. PUMP/MOTOR VARIETY & APPLICATION We can use almost any variety of pump flow rates or motor voltages with the option 427A. It can even be configured on reverse flow systems, Remote Pumping Units or virtually whatever can be imagined. A 427A Duplex Pumping System That Is Remote Pumping Unit Mounted P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-5 CIRCUIT BREAKERS Most circuit breakers are mounted within a side mounted enclosure with a NEMA rating to match your requirements. They are used to break power to the overall fuel system, pump motors, and other special circuits such as oil coolers. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-6 ENCLOSED INDUSTRIAL CONTROL PANEL Pryco’s OPTION # 465 — ENCLOSED INDUSTRIAL CONTROL PANEL is U/L Listed (Label # 508). We start with a heavy gauge steel enclosure that meets U/L requirements. Then we ensure only U/L Listed components are used within. These components the make up various day tank accessories include: contactors, relays, sockets, lights, and switches — even the wire and connectors. The unique U/L File Number specifically assigned to Pryco is E1023272. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-7 465 Enclosed Industrial Control Panel PRYCO ELCLOSED INDUSTRIAL CONTROL PANEL—OPTION #465 AX-8 Phone - 217 / 364-4467 Fax - 217 / 364-4494 P.O. Box 108, Mechanicsburg, IL 62545 REMOTE FILL PANEL This weatherproof fill panel (Option # 226) is for remote monitoring of “off street” bulk filling. When your day tank or sub-base tank is 90% filled, a warning light comes on and an alarm horn sounds. If pumping continues, a second light comes on at 95% capacity and an alarm horn sounds. At this time, an optional solenoid valve will close allowing no more fuel to enter the tank. It comes with a lockable hasp and is U/L listed. A mechanical drawing of Remote Fuel Fill Panel is on the reverse side. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-9 PRYCO REMOTE FILL PANEL—OPTION #226 P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-10 REMOTE FILL STATION Pryco’s Remote Fill Station is a lockable. weatherproof, dualdoor enclosure. It is designed for curb-side filling of aboveground fuel oil storage tanks via hose connection from a delivery truck. The left-side Electrical Compartment (shown below) houses control components, such as, alarms, and switches. The dualcompartment design allows the electrical components to be totally isolated from the fueling area. The Fueling Compartment (shown below) is located behind the right door. It features a 2” or 3” Cam-and-Groove connector, a check valve and a manual shut-off valve. This compartment is designed with a 7-1/2 gallon containment sump with a drain connection. When the tank being filled reaches a 90% set point, a warning light comes on and an alarm horn sounds. If filling continues, a second light comes on at 95% capacity and an alarm horn again sounds. At this time, an optional solenoid valve will close allowing no more fuel to enter the tank. A silence switch and remote contact outputs are standard. Optional features include: Solenoid Valve, Flush Mounting Adapter, Post Mounting Kit, Lockable Drain Valve, Dry Break Disconnect Adapter, Analog Level Gauge (tanks up to 48” deep), Digital Level Gauge (tanks up to 80” deep), A mechanical drawing of Remote Fill Station is on the reverse side. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-11 CONTROL PANEL PRYCO REMOTE FILL STATION—OPTION #230 P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-12 DRIP BASIN This drip basin (Option # 229) is designed to catch any fuel dripping from the fill hose. Its capacity is one gallon and has a drain hole inside of the basin to allow dripped fuel to run into tank. The basin lid comes with a gasket and a lockable hasp. The basin is epoxy coated inside and painted an industrial color of choice outside. A mechanical drawing of a Drip Basin is on the reverse side. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-13 PRYCO DRIP BASIN — OPTION #229 P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-14 SPILL CONTAINER PRYCO’S NEW SPILL CONTAINER —provides aboveground overflow environmental protection by preventing spills during tank filling. Adaptable for free-standing or sub-base tanks. WALL MOUNT BRACKET — A standard feature is a wall bracket to provide secure and stable mounting of the spill container. FEATURES include: Heavy 12-Gauge Construction 7 1/2 Gallon Capacity Built-In Drain Release-To-Tank Valve Hinged Cover w/Lockable Hasp For Added Safety Male NPT Connection For TankTop Installation CONNECTION: Available in three sizes to suit most applications: 2” …..Model #227-2 3” …..Model #227-3 4” …..Model #227-4 FINISH: Available in standard industrial colors—enamel finish and stainless steel P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-15 REAR VIEW BOTTOM VIEW 16.50 18.00 SIDE VIEW 5 2.0 3 14.00 6 18.0625 1 2 5 2 6 14.50 FRONT VIEW 6 4 4 5 1.00 7.25 5 5.25 16.00 18.00 3 3 3.25 10.125 PRYCO SPILL CONTAINER — OPTION #227 P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-16 OIL COOLER Option # 352, Fuel Oil Cooler, reduces the temperature of hot fuel that is returned from the engine to the day tank. Normally, an oil cooler is top-mounted on larger day tanks (because they have room on the top surface), or side mounted on medium size tank. On smaller tanks, sub-base units, or when required, an oil cooler is relocated to a free standing base. Mechanical drawings of the three mounting configurations are shown on the following pages. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-17 PRYCO OIL COOLER — OPTION #352 (SIDE MOUNTED) P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-18 PRYCO OIL COOLER — OPTION #352 (TOP MOUNTED) P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-19 PRYCO OIL COOLER — OPTION #352 (FREE STANDING) P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-20 BATTERY BOXES Option Code Length Width Height Battery Sizes Heater B01 23” 12” 12” 1 - 4D or 1- 8D n/a B02 44” 12” 12” 2 - 4D or 2 - 8D n/a B04 44” 12” 12” 2 - 4D or 2 - 8D 100 w. , 115vac w/Thermostat Pryco has four standard sizes of battery boxes. The sizes are shown in accompaning table. Also, we can custom build sizes and configurations to meet your specifications. The battery boxes are a waterproof enclosure with hinged cover with a lockable hasp and carring handles. They are epoxy coated inside for corrosion resistance and painted black or an industrial color of choice. A mechanical drawing of Battery Boxes is on the reverse side. P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-21 PRYCO BATTERY BOX — OPTIONS #B01-B04 P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-22 BATTERY FRAMES Standard Battery Frame Seismic Battery Frame Pryco has four standard sizes of battery frames and two different designs. The first is our “standard” design that will accomodate most applications. The second, our “seismic” design, has a top hold-down frame with heavy duty rods bolted up from the bottom frame. The sizes are shown in accompaning table. Also, we can custom build sizes and configurations to meet your specifications. The standard battery frames are 4” high and the seismic units are 12.25” high. Both are constructed of formed 7-gauge steel. They are painted black or an industrial color of choice. Mechanical drawings of both Battery Frame designs are on the following pages. Option Code Length Standard Width Seismic Width Battery Sizes F01 22” 10” 20” 1 - Group 4D F02 22” 12” 20” 1 - Group 8D F03 44” 10” 20” 2 - Group 4D F04 44” 12” 20” 2 - Group 8D P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-23 PRYCO BATTERY FRAME — OPTIONS #F01-F04 P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-24 PRYCO BATTERY FRAME SEISMIC — OPTIONS #FS01-FS04 P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-25 EMERGENCY VENTS SPRING-LOADED EMERGENCY VENT OPTION 321 This low profile vent cap is designed for use on all Pryco fuel tanks. It is available in 2” thru 6” sizes to accommodate the full range of emergency vent openings. The spring-loaded design provides for horizontal or vertical installation positioning. Vent units are calibrated to an 8-oz opening internal tank pressure. OPTION SIZE VENTING 321A 2” NPT 31,600 CF/H 321B 3” NPT 63,200 CF/H 321C 4” NPT 105,000 CF/H 321D 6” NPT 265,000 CF/H Website: www.Pryco.com Email: [email protected] P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-26 EVOLUTION PLC EVOLUTION PLC FUEL SYSTEM CONTROLLER OPTION 800 The EVOLUTION is a Programmable Logic Controller (PLC) based system designed to control and monitor the activities of up to four pumps and motors of a Pryco fuel supply system. A color touch screen displays system functional status, alarm conditions, and historical logs. The Evolution PLC provides operational control of the overall fuel system. An ultra-sonic sensor accurately determines the level of the fuel in the tank. Electronic “action levels” settings control the activities of pumps and motors (supply and reverse flow), and initiate signals for a full compliment of alarm conditions activating a common external alarm, light, or similar device. Using licensed software, WindSRV ä, it possible to link your OPC (object linking of devices for process control) or DDE (older version of OPC) compliant Windows ä - based software to any IDEC programmable logic controller. This link may use an optional built-in RS232 or RS485 serial interface adapters, or longer range Ethernet networking. That means any industrial HMI*, SCADA, general data acquisition, MES, or ERP will connect through WindSRV to Evolution system. All you have to do is install the server software on your PC running Windows, and you have a low-cost data acquisition and monitoring system using your own computer and the Evolution PLC. The basic PLC portion of the Evolution system is made up of a power supply module, an ultrasonic sensor mentioned above, and a logic controller that controls and processes incoming data and initiates pump motor activities and alarms as necessary. A graphical, color LCD Touch-Screen provides an Operator Interface Terminal. Depending upon the requirements of the fuel system design, an optional communications module and/or an optional (additional) I/O module may be added. The Evolution system is U/L Listed. Email: [email protected] Website: www.Pryco.com P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 AX-27 PRYCO, INC. FCM Detail Specifications PRYCO, INC. FUEL CONTROL and MONITORING SYSTEM DETAIL SPECIFICATIONS P. O. Box 108, Mechanicsburg, IL 62545 Page 1 FCM Detail Specifications PRYCO, INC. INTRODUCTION PRYCO’s FUEL CONTROL and MONITORING (FCM) system is the most sophisticated and powerful control tool available for your fuel supply system -- electronic or mechanical. It may be mounted on a day tank, subbase tank or a remote pumping unit. FCM is a computerized total system designed to control and monitor the activities of up to four pumps and motors. Through electronic settings, the assigned duty of the four pumps and motors can be any combination of Fill or Reverse Flow. STANDARD FEATURES • • • • • • • • • • • • • • • Ultra-Sonic Sensor - 4-20ma 24vdc Input For Continuous Operation (Main, Auxiliary or Backup Power to FCM) Power Available LED System Ready LED Electronic Fuel Gauge HOA Switch Control Panel System Test Switch Control Panel Alarm Test Switch Control Panel Alarm Reset Switch Control Panel Audible Alarm Silence Switch Safety High Switch w/Fill Motor Shut Down [1] High Fuel Level Notification [1] Low Fuel Level Notification [1] “Dry Tank” Prevention w/Reverse Pump Shut Down (will be replaced by Critical Low, if purchased) Secondary Containment Leak Detection (when optional rupture basin or double wall construction specified) OPTIONS • • • • • • Controls and Piping for Duplex Fill Pump & Motor Lead/Lag Alternation Of Duplex Fill Pumps/Motors Controls and Piping for Reverse Flow Pump(s) - Single or Duplex Lead/Lag Alternation Of Duplex Reverse Flow Pumps/Motors Pump(s) Fail Detection w/Automatic & Manual Reset Critical Low Level Notification (see footnote on preceding page) ______________________________ [1] These features include a Control Panel Alarm LED and an N.O. & N.C. Remote Signal Contacts for Engine Shut Down, etc. P. O. Box 108, Mechanicsburg, IL 62545 Page 2 PRYCO, INC. FCM Detail Specifications FCM STANDARD FEATURES THE INTERFACE BOARD The Interface Board is where external devices, such as pump motors, heaters, alarms, etc., are connected. Features of this board are: • • • • • • connectors for incoming 120vac power, a connector to supply 24vdc main, auxiliary or back up power for the FCM system only. (This 24vdc power is also supplied to a modem, if installed, to keep the FCM “on line”.) a Normally Open (N.O.) relay for each pump motor. The “ON/OFF” setting of this relay is controlled by the FCM Firmware (a computer program that “talks” directly to the FCM hardware). a N.O. relay to control operations of an optional heater, a set of “dry contact” connectors for the following: • remote annunciation of abnormal level detection. These six-position connectors are a direct extension of a relay that FCM activates (both N.O. and N.C.) when the following levels have been read by the UltraSonic Sensor or from external switches: High Fuel level, Low Fuel level, Critical Low level, Critical High level, and secondary containment leak detector. • Pump Fail (no fuel detected in the fuel line) and control. These connectors/relays are similar to the preceding N.O. and N.C. remote annunciation except FCM activates the relay based upon input from a flow switch. There are two additional terminals on each connector that receives the input. other supporting electronic parts and components. NOTE – Being Dry Contacts, external power must be supplied for any remote alarms and lights. ULTRA-SONIC SENSOR 4-20ma This device emits a signal downwards into a tube extending the depth of the tank. When the signal encounters an object (the fuel), it bounces back to the emitting device that has a built-in receiver. The elapsed time between emission of the signal and its return is converted into an electrical voltage, which in turn, is changed to inches of air space from tip of emitter to fuel level. Important to note - nothing (inductance probe, or such) touches the fuel. Hence, there are no erratic and low voltage level readings caused by gum-up or other undesirable phenomenon which are inherent to similar out-dated systems. Periodic cleaning and readjustment of probes and the system is not necessary. P. O. Box 108, Mechanicsburg, IL 62545 Page 3 FCM Detail Specifications PRYCO, INC. ELECTRONIC FUEL LEVEL GAUGE This gauge is an electronic measurement of the fuel level. It features a set of eight LED’s to report the usable fuel in the tank. The 100% or FULL level is normally set to the Fill Pump shut off level (not the top of the tank); the EMPTY level of the gauge is normally set to the bottom of the tank. Each lighted LED represents fuel present at a linear determination of about 1/8 of the calculated usable span. 24vdc ALTERNATE/AUXILIARY POWER INPUT 120vac is the normal voltage for the FCM; however, there are some cases where it is not available or it may be desirable to use “battery” power. At startup time, if 120vac power is not available, FCM automatically switches to 24vdc as an alternate voltage for its internal power. If 120vac power is interrupted for whatever reason and a 24vdc auxiliary power, such as a battery, is connected to the FCM, it will automatically switch to its alternate power input and normal operations continue. POWER AVAILABLE LED This green LED is used to report that power is on and the FCM is energized. It does not imply the FCM is functioning properly (FCM system performance is reported by the System Ready LED). SYSTEM READY LED This slow flashing yellow LED reports the status of the overall FCM system. When the system is powered on, the above POWER AVAILABLE LED is turned on and the system undergoes a “Power On Self Test” (POST). All features and options are checked internally for reasonableness to ensure they are operational and within tolerances. If all POST checks are completed successfully, the SYSTEM READY LED is turn on and the FCM is then operational. HOA SWITCH This is actually a series of three switches per pump motor that function as an HOA switch in an OFF, ON and AUTO position. In an ON position, FCM surrenders control of the pump motor except actions at the specified control points -- Critical High, High Fuel, Low Fuel, and the Critical Low fuel levels. In the AUTO position, the FCM automatically controls the activities of the motors based upon fuel level readings and control points. P. O. Box 108, Mechanicsburg, IL 62545 Page 4 PRYCO, INC. FCM Detail Specifications SYSTEM TEST SWITCH This feature is used for a visual test of the LED’s only. When pressed, all LED’s on the control panel are lighted and should be illuminated. It does not test any monitor/control functions of the FCM. ALARM TEST SWITCH This feature actually tests the controls and relays associated with the four alarm levels (Critical High, High Fuel, Low Fuel and Critical Low), and the four pump fail functions. It is also a local visual test that will notify the operator of any error. ALARM RESET SWITCH This optional switch, located on the control panel, is used to turn off a visual alarm that had reported an abnormal condition that was corrected. When an abnormal condition exists, it is reported by changing the appropriate LED to a flashing ON state and sounds a horn, if installed. The LED continues to flash until the condition is corrected. Then: • if this option is not active, the LED is turned off automatically when the condition is corrected. • if this option is active, “Alarm Latching” is also active. Alarm Latching changes the flashing LED to a solidly lit LED when the condition is satisfied. This provides an historical account that an abnormal condition did occur. The solid LED remains lit until this optional switch is pressed. ALARM SLIENCE SWITCH This optional switch, also located on the control panel, is used to turn off an installed alarm horn that is sounding as an abnormal condition exists. (The horn will shut off automatically when the condition is corrected.) This is welcome relief to workers who are correcting the problem. P. O. Box 108, Mechanicsburg, IL 62545 Page 5 FCM Detail Specifications PRYCO, INC. SAFETY HIGH FEATURE This standard feature is always installed. It acts as a mechanical fail-safe to prevent flooding should an electronic fault occur preventing the Fill Pumps/Motors from shutting off at the specified level. The Safety High Level is always set to 3.0” down from the top of the tank. It will always shut off all Fill Pump/Motors (internally controlled by FCM). Two sets of Dry Contacts are provided, (1 - N.O. and 1 - N.C.). If the day tank is supplied by a gravity-feed main tank, this is a good place to receive a signal to close a normally open solenoid valve in the intake line. The customer must supply external power for any remote alarms/lights. HIGH FUEL FEATURE This standard feature is always installed. In its basic setup, when the fuel reaches a specified “high” level, it will turn on a High Fuel Light/Alarm. Optionally, as a safety feature, FCM can be programmed with a “Shut Fill Pump(s) Down” feature. The High Fuel Level is normally set to 3.5” down from the top of the tank. Additionally, two sets of Dry Contacts are provided, (1 - N.O. and 1 - N.C.). The customer must supply external power for any remote alarms/lights. LOW FUEL FEATURE This standard feature is always installed. When the fuel reaches a specified “low” level, it will turn on a light on the control panel and will shut off any installed Reverse-Flow Pumps/ Motors. Low Fuel Level is normally set at predetermined distance from the top of the tank. These settings are: Py5 & PY10 GGG.. 7.0” Py15 GGG.GGG. 12.0” Py25 - PY150 G..... 14.0” Py200 - PY1000 G.. 18.0” Two sets of Dry Contacts are provided, (1 - N.O. and 1 - N.C.). The customer must supply external power for any remote alarms/lights. P. O. Box 108, Mechanicsburg, IL 62545 Page 6 PRYCO, INC. FCM Detail Specifications “DRY TANK” PREVENTION This feature is to prevent the emptying of the tank due to reverse flow pump-out. If the customer did not purchase a Critical Low option, this feature is installed for fail-safe protection. Unlike a Critical Low, it does not support generator engine shut down or remote annunciation. It activation point is 3.5” from the bottom of the tank. SECONDARY CONTAINMENT SWITCH This is a standard feature that is activated when secondary containment is purchased. It will light an LED on the control panel and activate an alarm. Additionally, two sets of Dry Contacts are provided (1 - N.O. and 1 - N.C.) for remote annunciation. The customer must supply external power for any remote alarms/lights. FCM OPTIONAL FEATURES DUPLEX SUPPLY PUMP An additional fill pump and motor of any size and voltage may be installed on the day tank, subbase or on a remote pumping unit and controlled by FCM. This second pump/motor is referred to as Pump #2 on the FCM control panel and by software. FCM will control it regardless where it may be mounted. Pump #2 has its own set of “HOA” switches as well as a “turn ON” level, pump running LED, and a pump fail LED/reset switch. It will however, turn OFF at the same level as Pump #1 (the Standard Fill Pump/Motor). Pump #2, in its basic setup, is always in a “lag” position, i.e., it will only turn ON when the fuel level has dropped past a point where it has been determined that Pump #1 cannot keep up with the draw-down of the generator. The Alternation of Duplex Pumps option explained below will override this permanent “lag” assignment. If Alternation of Duplex Pumps option is not installed, Pump #1 is always referred to as the Primary Fill Pump and Pump #2 is the Secondary Fill Pump. P. O. Box 108, Mechanicsburg, IL 62545 Page 7 FCM Detail Specifications PRYCO, INC. REVERSE FLOW PUMP(s) - SINGLE or DUPLEX As a safety feature, the fuel supply system can be optionally configured with a sub-system that will pump the fuel in the day tank or subbase to another container – normally back to the main supply tank. This operation is referred to as “reverse flow”. It can be configured as either a single pump/motor or as a duplex. The single pump/motor of a reverse flow (or the first of a duplex setup) is always referred to as Pump #3. If the configuration is a duplex reverse flow, the second is Pump #4. Both reverse flow pumps have their own set of “HOA” switches, “turn ON” levels, pump running LEDS, and a pump fail LEDS and reset switches. And both share a common “turn OFF” level. Pump #4, in its basic setup, is always in a “lag” position, i.e., it will only turn on when the fuel level has risen past a point where it has been predetermined that Pump #3 cannot keep up with the filling of the tank. The Alternation of Duplex Pumps option explained below will override this permanent “lag” assignment. If Alternation of Duplex Pumps option is not installed, Pump #3 is always referred to as the Primary Reverse Pump and Pump #4 is the Secondary Reverse Pump. When a reverse flow pump is turned ON, the fill pump(s) will automatically be turned OFF in case either has caused the problem. The voltage, size, type of current, etc. of reverse flow pump(s) and motor(s) are not required to match those of the fill pump(s) and motor(s). ALTERNATION of DUPLEX PUMPS If the fuel supply system has been designed correctly and the “lead” pumps/motors (Pumps #1 & #3) have been sized to match the demands of the generator, and no unusual condition or problem arises, it is conceivable that the “lag” pumps/motors (Pumps #2 & #4) will never or very seldom see action. This “alternation” option switches the lead/lag assignment of each class (Fill or Reverse Flow) of pump/motor in an attempt to equalize the run time. When a pump motor (Fill or Reverse) is cycled into lead position, it is assumes the title as the Primary, whereas, the lag pump/motor is the Secondary. This does not change the fact that the secondary pump will back up the primary at a predetermined level. P. O. Box 108, Mechanicsburg, IL 62545 Page 8 PRYCO, INC. FCM Detail Specifications PUMP FAILURE w/MANUAL and AUTOMATIC RESET This option works in conjunction with an optional Flow Switch to report a “no fuel present” condition in the fuel line from the main storage tank. Without this option, there is a possibility of the pump losing its prime or running dry (which will eventually cause pump damage). When a pump/motor starts, there is a approximate 10 second delay to give the line time to get charged with fuel, if not already filled. After this delay, the FCM will initiate failure testing based upon a possible signal from the flow switch. If a “no fuel in line” condition is received, the FCM enters another approximate 10-second delay to validate the condition. After the second delay and “no fuel” condition still exists, the FCM determines that a failure has occurred and takes the following actions: • • • • shuts off pump/motor lights the appropriate LED (solid) sounds a horn, if installed. makes note of the “failed” pump intended action, i.e., the position of the HOA switch, “ON” or “AUTO” If the FCM is programmed to restart manually, it will wait for the operator to press the Reset switch to repeat the start-up process. Optionally (no charge), it is possible to allow the FCM to attempt to restart the pump/motor automatically (after the 10 + 10 delay when the motor was shut off). If the option is set to Auto-Restart and a specified time (1 to 240 minutes) has elapsed, the FCM will attempt the restart. This attempt to restart will continue indefinitely until the condition is corrected. Manual override is permitted during Auto-Restart. CRITICAL LOW OPTION This option is to prevent the emptying of the tank due to abnormal engine draw-down or reverse flow. It turns on an alarm condition and when wired to the ignition switch of the generator engine, will shut it off to prevent loss of prime and possible damage. The Critical Low level is normally set to 3.5” up from the bottom of the tank. Two sets of Dry Contacts are provided, (1 - N.O. and 1 - N.C.) to connect external alarm devices (N.O.) and to turn off the power to the engine ignition. The customer must supply external power for any remote alarms/lights. P. O. Box 108, Mechanicsburg, IL 62545 Page 9 FCM Detail Specifications PRYCO, INC. EXTERNAL CONNECTIONS INTERFACE BOARD LAYOUT The FCM Interface Board (graphically shown on page 15) is where connection(s) are made for all external inputs and outputs. Located on the left side of the board is a group of seven larger relays (referred to herein as the “30-amp relays”). These provide terminals connecting the incoming 120vac power for the FCM, and for the output of pump motors and an optional 120vac heater. There are smaller 5-amp relays (not shown) positioned around the remaining perimeter of the board. Associated with these relays are six and eight pin connectors. Both types of connectors have two sets of N.O. terminals for “dry contact” remote annunciation and two sets of N.C. for external actions, such as engine shut down. The rightmost terminals of the eight-position connectors are input from optional Fuel Flow Switches or from the Critical High and Rupture float switches. Finally, there are two other connectors: 1) two-position for 24vdc battery power for FCM system operational backup; and, 2) three-position for a N.O. or N.C. external Common Alarm connection. SPECIFICATIONS - 30-AMP RELAY Relay Type ------------- Single Pole - Single Throw Relay Load Rating --- 30 amp. @ 120vac - 1 hp rated Connector -------------- Normally Open (N.O.) SPECIFICATIONS - 5-AMP RELAY Relay Type ------------- Double Pole - Double Throw Relay Load Rating --- 5 amp. (600 watts @ 120vac) per pole Connector -------------- 2 sets of N.C. and N.O. POWER SUPPLY (FCM) PROTECTION The FCM system, like other electronic equipment, requires protection from a power outage caused by whatever. Pryco recommends the power for the operation of the FCM be conditioned and protected from damaging noise, spikes and other harmful influences. Such protection, normally referred to as a “UPS”, should have provision for battery backup. Pryco option #780 or a UPS from a computer store (not a simple surge arrestor/suppressor) will provide the protection from most problems. If your overall power system has an in-line UPS, connection of the FCM here will suffice P. O. Box 108, Mechanicsburg, IL 62545 Page 10 PRYCO, INC. FCM Detail Specifications LOW FUEL FCM GRAPHICAL LAYOUT ULTRA-SONIC SENSOR PUMP 2 FAIL HEATER PUMP #4 IN HIGH FUEL CRITICAL LOW 24vdc AUXILLARY FCM BOARD INPUT PUMP 1 FAIL PUMP #3 LINE IN 120vac NEUTRAL TRANSFORMER LEAK DETECTOR FUSE LINK INPUT IN CRITICAL HIGH PUMP #2 PUMP #1 IN IN ALARM PUMP 3 FAIL PUMP 4 FAIL IN FRONT OF TANK P. O. Box 108, Mechanicsburg, IL 62545 Page 11 FCM Detail Specifications PRYCO, INC. Over two acres under one roof is the home of Pryco — industry pioneers of safety, standards, and codes for fuel systems for emergency and standby power generation systems. PRYCO, INC. 3rd & Garvey Streets P. O. Box 108 Mechanicsburg, IL 62545 Phone: 217 / 364-4467 Fax: 217 / 364-4494 Web Site: www.pryco.com Email: [email protected] P. O. Box 108, Mechanicsburg, IL 62545 Page 12 PRYCO, INC. EVOLUTION SYSTEM Detail PRYCO, INC. FUEL CONTROL and MONITORING SYSTEM PRODUCT DESCRIPTION P. O. Box 108, Mechanicsburg, IL 62545 Page 1 EVOLUTION Detail Specifications PRYCO, INC. INTRODUCTION The EVOLUTION is a Programmable Logic Controller (PLC) based system designed to control and monitor the activities of up to four pumps and motors of a Pryco fuel supply system. A color touch screen displays system functional status, alarm conditions, and historical logs. The Evolution PLC provides operational control of the overall fuel system. An ultra-sonic sensor accurately determines the level of the fuel in the tank. Electronic “action levels” settings control the activities of pumps and motors (supply and reverse flow), and initiate signals for a full compliment of alarm conditions activating a common external alarm, light, or similar device. Using licensed software, WindSRV , it possible to link your OPC (object linking of devices for process control) or DDE (older version of OPC) compliant Windows - based software to any IDEC programmable logic controller. Modbus protocol is standard. This link may use an optional built-in RS232 or RS485 serial interface adapters, or longer range Ethernet networking. That means any industrial HMI*, SCADA, general data acquisition, MES, or ERP will connect through WindSRV to Evolution system. All you have to do is install the server software on your PC running Windows, and you have a low-cost data acquisition and monitoring system using your own computer and the Evolution PLC. The basic PLC portion of the Evolution system is made up of a power supply module, an ultrasonic sensor mentioned above, and a logic controller that controls and processes incoming data and initiates pump motor activities and alarms as necessary. A graphical, color LCD Touch-Screen provides an Operator Interface Terminal. Depending upon the requirements of the fuel system design, an optional communications module and/or an optional (additional) I/O module may be added. The Evolution system is totally electronic except for a redundant fail-safe critical high level sensor. The Evolution System * HMI (Human Machine Interface), SCADA (Supervisory Control and Data Acquisition), MES Manufacturing Execution System) or ERP (Enterprise Resource Planning) P. O. Box 108, Mechanicsburg, IL 62545 Page 2 PRYCO, INC. EVOLUTION SYSTEM Detail 24 VDC POWER SUPPLY This compact power supply has Universal input voltage for Worldwide industrial integration with primary switched-mode regulator technology. It features low output ripple 24 VDC and a 240 Watt / 10 Amp (shown below) or a 120 Watt / 5 Amp output rating. The output is electronically protected against overloads and short circuits. Power Supply Specifications (120 and 240 watts units): Input Voltage Universal Input 85-264 VAC;100-350 VDC Input Current 120 watts—1.8 Amp (Maximum@100VAC) 240 watts—3.5 Amp Output Voltage 24 VDC Output Current 120 watts—5 Amp 240 watts—10 Amp Internal Fuse Rating 120 watts—4 Amp 240 watts—6.3 Amp Voltage Adjustment ±10% (V. Adj Control on Front) Over Voltage Protection 120% minimum Shutdown Over Current Protection 103% to 110%, Auto Reset “Power-On” Indicator LED (Green) “Voltage Low” Indicator LED (Amber) Operating Temperature -10º C to 60º C (14º to 140º F) Operating Humidity 20% to 90% - Relative (No Condensation) Special Certifications – Class1-Div2 Rated (UL1604), Semi F47 Approved, UL508 Applicable Directives - EMC: EN61204-3 (EMI: Class B, EMS: Industrial), EN50178, EN61000-3-2 A14 class A, LVD: EN60950 P. O. Box 108, Mechanicsburg, IL 62545 Page 3 EVOLUTION Detail Specifications PRYCO, INC. ULTRA-SONIC SENSOR 4-20ma This device emits a signal at a narrow beam angle downwards into a tube extending the depth of the tank. When the signal encounters an object (the fuel), it bounces back to the emitting device that has a built-in receiver. The elapsed time between emission of the signal and its return is converted into an electrical voltage, which then is changed to inches of air space from tip of emitter to fuel level. Important to note - nothing (inductance probe, or such) touches the fuel. Hence, there are no erratic and low voltage level readings caused by gum-up or other undesirable phenomenon which are inherent to similar outdated systems. Periodic cleaning and re-adjustment of probes and the system is not necessary. LOGIC CONTROLLER—CPU This rugged, compact module is “brains” of the Evolution system. Logic procedures direct various action to be initiated based upon input from the Ultra-Sonic level sensor or external sensing switches. This module formats and directs the display of the variable content of the LCD screen pages and to the Communications Module (below) as actions and conditions occur. A standard RS232C port is built into every CPU controller module. This port is rated for a maximum of 50 ft. and is dependant on cabling, electrical noise, etc. The distance can be expanded to 656 feet by specifying RS485 communications. Modbus protocol is standard. This link may use either built-in RS232 or optional RS485 serial interface adapters, or longer range Ethernet networking. If you need to expand the distance, additional ports, or a different protocol, you may add a Communications expansion Modules (described in the Optional equipment of this brochure). CERTIFICATION CE Marked, TÜV, c-UL, UL 508, UL 1310 (PS5R-SB, -SC, -SD), UL 1604, EN 50178:1997, LVD: EN60950:2000, EMC: Directive, EN61204-3:2000 (EMI: Class B, EMS: Industrial) Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1. P. O. Box 108, Mechanicsburg, IL 62545 Page 4 PRYCO, INC. EVOLUTION SYSTEM Detail OPERATOR INTERFACE TERMINAL A 5.7 inch LCD touch-screen provides a series of graphical data presentations in vivid color to monitor and control the Evolution system. Illuminated “soft” pushbuttons replace physical mechanical switches to allow an operator to input data to control the operation of the fuel system. Illuminated graphic lamps communicate on/off normal states and report alarm conditions. MAIN MENU This is the “home” touch screen page of the Evolution system. From here, using soft buttons an operator may select subsequent pages to monitor and control the fuel system PLC. SYSTEM MENU This password protected page contains critical information relevant to the overall Evolution PLC system. The system password is maintained here. CONTROL PANEL This is the monitoring screen page. Each monitored feature that is available to the system is represented here as a solid illuminated lamp. If a feature becomes “active” the lamp graphic flashes. An operator can determine at a glance if the system is operating normally. Two yellow linear-scaled graphics report fuel level in “percent full” and in gallons. A digital readout of number of gallons (blue) is shown above these areas. Two soft push-button switches are also located on the page—an “ALARM SILENCE” switch, which is a standard feature; and a “PUMP FAIL RESET” switch if an optional fuel flow switch (option # 372) is installed. P. O. Box 108, Mechanicsburg, IL 62545 Page 5 EVOLUTION Detail Specifications PRYCO, INC. PUMPS & MOTORS This page contains input HOA switch and light graphics where an operator can control each pump motor of the fuel system. A motor may operate in either automatic or manual mode. The illuminated LCD boxes to the right of each switch report the switch position of its associated motor. Each pump and motor has it own HOA switch along with run-time hour display. Motor assignments are: • • • Standard Duplex Mode—(Supply or Reverse) Pump and Motor 1 is always “lead pump”; (Supply or Reverse) Pump and Motor 2 is always “lag Pump” Automatic Mode—Will alternate “lead pump” upon each initial start cycle. Manual Mode—User defined “lead pump” using lead/lag soft push-button switch. HISTORY This screen page reports a time/date historical log of pump motor activities and alarm conditions. The soft push-buttons at bottom assist in scrolling through the log. PARAMETERS This password-protected page contains level settings at which specified actions (pump motor on/off, high low fuel levels, etc.) are to begin. Optional Pump fail timers are also displayed for user defined time. This allows dynamic fine tuning at the job sight. P. O. Box 108, Mechanicsburg, IL 62545 Page 6 PRYCO, INC. EVOLUTION SYSTEM Detail STANDARD FEATURES The Evolution system comes with an impressive list of standard features: • • • • • • • • • • • • • • • 120/240 VAC-to-24 VDC power supply—“safety extra-low voltage” (SELV) (Page 3) Ultra-Sonic Sensor (Page 4) Color LCD Touch Screen for an Operator Interface Terminal (Page 5) Fuel Level Gauge Scaled in Percent Full and Gallons (Page 7) Power Available Annunciator Light (Page 7) HOA Switching (Page 7) Audible Alarm Silence Switch (Page 8) Critical High Notification Feature (Page 8) High Fuel Level Notification Feature (Page 8) Low Fuel Level Notification Feature (Page 8) Critical Low Level Notification Feature (Page 8) Secondary Containment Detection Alarm Notification (Page 8) Discrete Normally Open (N.O.) Contacts for All Alarms (Page 8) Historical Log (Page 8) Modbus Protocol (Page 2) ELECTRONIC FUEL LEVEL GAUGE Two graphical gauges that represent fuel level in the tank. They display both percent full and gallons remaining. The 100% or FULL level is normally set to the Fill Pump shut off level (not the physical top of the tank); the EMPTY level of the gauge is normally set to the bottom of the tank. POWER AVAILABLE “LIGHT” This green LED lamp at the bottom of the LCD touch-screen is used to report that power is on and the Evolution system is energized. HOA SWITCH An HOA soft push-button switch is displayed for each pump motor on the PUMP & MOTOR screen page. • In the ON position, the EVOLUTION system surrenders automatic control of the pump and motor except at action levels at the specified control points --Reverse pump(s) on, Critical High and High Fuel. • In the AUTO position, the EVOLUTION system automatically controls the activities of the motors based upon fuel level readings and control points. • In the OFF position, the pump motor is offline to all actions. P. O. Box 108, Mechanicsburg, IL 62545 Page 7 EVOLUTION Detail Specifications PRYCO, INC. STANDARD FEATURES—CONTINUED ALARM SLIENCE SWITCH This soft push-button switch is used to silence a common alarm horn (if installed) that will sound if an abnormal condition exists. (The horn will shut off automatically when the condition is corrected.) CRITICAL HIGH FUEL NOTIFICATION FEATURE This feature will illuminate the Critical High Alarm lamp graphic on CONTROL PANEL screen page when fuel level reaches a predetermined set point, plus shut-down any supply pump(s). Sends a signal to a common alarm output. If the day tank is supplied by a gravity-feed main tank, this is a good place to receive a signal to close a normally open solenoid valve in the inlet line. A Critical High Alarm Dry Contact (1 - N.O) and a Common Alarm Dry Contact (1 - N.O) are provided, HIGH FUEL NOTIFICATION FEATURE This feature will illuminate the High Alarm lamp graphic on CONTROL PANEL screen page when fuel level reaches a predetermined set point, plus shut-down any supply pump(s). Sends a signal to a common alarm output. A High Alarm Dry Contact (1 - N.O) and a Common Alarm Dry Contact (1 - N.O) are provided. LOW FUEL NOTIFICATION FEATURE This feature will illuminate the Low Alarm lamp graphic on CONTROL PANEL screen page when fuel level reaches a predetermined set point. Sends a signal to a common alarm output. A Low Alarm Dry Contact (1 - N.O) and a Common Alarm Dry Contact (1 - N.O) are provided. CRITICAL LOW FUEL NOTIFICATION FEATURE This feature will illuminate the Critical Low Alarm lamp graphic on CONTROL PANEL screen page when fuel level reaches a predetermined set point. Sends a signal to a common alarm output. A Critical Low Alarm Dry Contact (1 - N.O) and a Common Alarm Dry Contact (1 N.O) are provided. TANK RUPTURE ALARM NOTIFICATION This feature will illuminate the Tank Rupture lamp graphic on CONTROL PANEL screen page when a Tank Rupture occurs, plus shut-down any supply pump(s). Sends a signal to a common alarm output. A Tank Rupture Alarm Dry Contact (1 - N.O) and a Common Alarm Dry Contact (1 - N.O) are provided, HISTORICAL LOG The EVOLUTION system maintains a time/date stamped log of events pertaining to activities of its operation. P. O. Box 108, Mechanicsburg, IL 62545 Page 8 PRYCO, INC. EVOLUTION SYSTEM Detail EVOLUTION SYSTEM OPTIONAL FEATURES PLC MEMORY MODULE (Option #805) Used to expand PLC memory (32KB and 64KB) program upgrade as necessary. COMMUNICATIONS MODULES (Option #810) This optional strong communications module directs Logic Controller output downstream to your in-house system. The system can accommodate up to a total of seven communication ports. Acting as a slave to in-house building management systems, Modbus protocol is standard. This optional module provides RS485/RS232 for data link or modem communication extending distance rating beyond the 50 foot range to 656 feet. BLACK-BOX CONVERTER (Option #812) Used to convert RS485 PLC output to RS232 if customer system does not have RS485 connection capabilities. ANALOG MODULE (Option #815) A PLC module that provides a set of 2 each 4-20 MA output connectors. DUPLEX SUPPLY SYSTEM, PLC CONTROLLED (Option #827) An additional set of secondary controls, piping and standard 2 GPM pump & 1/3 HP motor “lag” system to back-up primary “lead” pump/motor. Normally the lead pump/motor begins operation at 86% usable fuel capacity; the lag system begins at 82%. Both systems turn off at 100% capacity. DUPLEX SUPPLY SYSTEM, PLC CONTROLLED, w/AUTOMATIC LEAD/LAG PUMP SWAP (Option #827A) Same as Option 827 plus HOA switching capability to automatically alternate each pump/motor into the lead starting position. DUPLEX SUPPLY SYSTEM, PLC CONTROLLED, w/MANUAL LEAD/LAG PUMP SWAP (Option #827B) Same as Option 827 plus switching capability to manually alternate each pump/motor into the lead starting position. SOFTWARE (Option #830) WindSRV for in-house building management system’s PC drivers P. O. Box 108, Mechanicsburg, IL 62545 Page 9 EVOLUTION Detail Specifications PRYCO, INC. OPTIONAL FEATURES—CONTINUED COVER (DAY TANK w/PLC)—NEMA-1 ENCLOSURE for PLC TANK MOUNTED SYSTEMS (Option #834-x) 834-1—SINGLE pump and motor (replaces the single pump/motor cover that is standard equipment for all day tanks). 834-2—DUPLEX (2) pumps, motors, and control components. This cover is standard equipment And included with duplex supply pumps & motors with Options 827, 827A, or 827B. 834-3—TRIPLEX (3) pumps, motors, and control components. 834-4—QUAD (4) pumps, motors, and control components. WEATHERPROOFING For OPTION 834 SERIES COVERS (Option #835) A NEMA 3R rated enclosure to provide protection against normal weather elements. The control panel viewing area is covered with sealed plexi glass and all openings are piped-through. Inside, a pan provides protection from flooding. ENCLOSURE, WALL MOUNT (Option #870x) For locating all PLC components, except the ultrasonic sensor, from tank mount 870-1620-1—NEMA 1 enclosure (16” x 20” x 8.75”) 870-2020-3R—NEMA 3R enclosure (20” x 20” x 8”) 870-1616-4—NEMA 4-12 enclosure (16” x 16” x 8”) 870-1620-4S—NEMA 4-12 enclosure w/security window (16” x 20” x 8”) PUMP FAIL DETECTION (Option #873) This option works in conjunction with an optional Flow Switch to report a “Pump Fail Alarm” condition in the fuel line from the main storage tank. Without this option, there is a possibility of the pump running dry (which will eventually cause pump damage). When a pump/motor starts, if fuel is not detected after the users predetermined set time (0-99 seconds. The respective pump/motor will be shut-down. If system has the duplex pump/motor option, second pump/motor will start after first pump/motor times out. If second pump/motor does not detect fuel, it will be shut-down after the user predetermined set time. This is standard operation for Supply pump(s) or Reverse pump(s) with duplex pumps. All pump fail alarms have a common manual reset switch that must be pushed to reset and clear the alarm and reset the pump/motor. A PLC feature, w/manual reset, to detect “no fuel” In fuel line (requires an inline Flow Switch Option #372). POWER SUPPLY PROTECTION (Option #880) A PLC module that provides surge protection of delicate PLC components high rating capacity, thermal protected P. O. Box 108, Mechanicsburg, IL 62545 Page 10 PRYCO, INC. EVOLUTION SYSTEM Detail OPTIONAL FEATURES—CONTINUED REVERSE FLOW PLC CONTROLS—IN GENERAL (Option #899 series) As a safety feature, the fuel supply system can be optionally configured with a sub-system that will pump the fuel in the day tank or subbase to another container – normally back to the main supply tank. This operation is referred to as “reverse flow”. It can be configured as either a single pump/motor or as a duplex. The single pump/motor of a reverse flow (or the first of a duplex setup) is always referred to as Pump #3. If the configuration is a duplex reverse flow, the second is Pump #4. Both reverse flow pumps have their own set of “HOA” soft push-buttons, “turn ON” levels, “turn OFF” levels, and pump running illuminated lamps. The voltage, size, type of current, etc. of reverse flow pump(s) and motor(s) are not required to match those of the fill pump(s) and motor(s). REVERSE FLOW PLC CONTROLS and PLUMBING FOR A SINGLE PUMP/MOTOR (Option #899-1) The controls and tank plumbing required for a single reverse flow pump and motor to pump fuel back to main tank. Pump and Motor must be ordered separately. REVERSE FLOW PLC CONTROLS and PLUMBING FOR A DUPLEX PUMP/MOTOR (Option #899-2) The controls and tank plumbing required for two reverse flow pump and motor to pump fuel back to main tank. Pumps and Motors must be ordered separately. PLC CONTROLS and PLUMBING for DUPLEX REVERSE FLOW SYSTEM w/ AUTOMATIC LEAD/LAG PUMP SWAP (Option #899A) Same as Option 899-2 with a HOA switch to automatically alternate each pump/motor into the lead starting position. Pumps and Motors must be ordered separately. PLC CONTROLS and PLUMBING for DUPLEX REVERSE FLOW SYSTEM w/MANUAL LEAD/LAG PUMP SWAP (Option #899B) Same as Option 899-2 with a switch to manually alternate each pump/motor into the lead starting position. Pumps and Motors must be ordered separately. P. O. Box 108, Mechanicsburg, IL 62545 Page 11 EVOLUTION Detail Specifications PRYCO, INC. Over two acres under one roof is the home of Pryco — industry pioneers of safety, standards, and codes for fuel systems for emergency and standby power generation systems. PRYCO, INC. 3rd & Garvey Streets P. O. Box 108 Mechanicsburg, IL 62545 Phone: 217 / 364-4467 Fax: 217 / 364-4494 Web Site: www.pryco.com Email: [email protected] Catalog Number — 0010-4.0 (1/01/2010) P. O. Box 108, Mechanicsburg, IL 62545 Page 12
Similar documents
standard features
As a safety feature, the fuel supply system can be optionally configured with a sub-system that will pump the fuel in the day tank or subbase to another container – normally back to the main supply...
More information