ELECTRIC WIRE ROPE HOIST - Donati Sollevamenti Srl
Transcription
DRH SERIES ELECTRIC WIRE ROPE HOIST TOP QUALITY PRODUCTS FROM A LEADING COMPANY DONATI SOLLEVAMENTI S.R.L. OFFERS A PRODUCT IN LINE WITH THE MOST MODERN INTERNATIONAL STANDARDS. Donati Sollevamenti S.r.l. was founded in Italy in 1930 and has since earned a leading position on the international market for lifting and handling equipment, with exports accounting for around two thirds of its total turnover. Donati joined the MHPS (Material Handling & Port Solutions) segment of Terex Co. USA (www.terex.com) in 2011 providing additional exposure and support for Donati products on the world market. The advanced design and construction features of all Donati products, are the basis for the competitiveness and reliability of the entire range, which is suitable for all manufacturing industries and tertiary distribution. Donati designs and manufactures its products in Italy, so its marketing mix is known for it vast range (standard and special solutions), excellent quality/price ratio, fast response and delivery; it is the ideal partner for bridge crane manufacturers, material handling integrators and distributors as well as service companies specialising in retrofitting/refurbishing. If Donati is known on the market for its constant focus on customer satisfaction, its in-house priorities are the quality of processes, safety in the plant and the environment (and Donati is ISO 9001 - ISO 14001 OHSAS 18001 certified). Donati also complies with the provisions of Italian Legislative Decree 231/01 concerning the administrative responsibility of legal entities and companies (governing Compliance, and also Safety and the Environment). 2 DONATI’S LIFTING RANGE The product range covers all aspects of industrial lifting always offering an unbeatable quality/price ratio along with a pleasing and professional design. The DMK electric chain hoists for capacities up to 4,000 kg, jib cranes with manual and electric rotation, DRH electric wire rope hoists with capacities up to 50,000 kg, DSC channel profiles and DGP offset gear motors, all represent an affordable and safe solution in any situation. The special configurations of each product and on request CSA homologation for DMK and DRH hoists, complete the range guaranteeing a solution to the most diverse and specific application needs. DONATI SOLLEVAMENTI’S constant focus on customer satisfaction is aimed at establishing a long-term relationship, based on mutual respect and trust, thanks to the flexibility and prompt response of its organisation and direct and personal contact. The after-sales service is managed to provide prompt answers and solutions for spare parts, servicing and warranties. ELECTRIC WIRE ROPE HOIST DRH SERIES THE MOST RELIABLE AND SAFE WAY OF LIFTING It guarantees maximum safety in hoisting up to 50,000 kg. The skill and experience in design and production, the quality of components used, the high technology employed in machining mechanical parts, in the finish and surface treatments as well as the EN ISO 9001: 2008 certified quality system which covers all of the company’s activities, allow DONATI SOLLEVAMENTI to offer a product in line with the most modern international regulatory standards. The DRH electric wire rope hoist ensure wide range of uses, reliability over time and safety in all operating phases. The special water-repellent paintwork, applied with a completely enclosed electrostatic process, guarantees durability and constant top performance. The company offers a 3-year warranty starting from the date of delivery, all with excellent value for money. ELECTRIC WIRE ROPE HOISTS POWERFUL AND SAFE TROLLEYS AT YOUR SERVICE The hoist combined with a trolley which runs on one or two beams also allows horizontal movements. All lifting (raise and lower) and traverse (right and left) movements are activated by a pushbutton panel or radio-control system. The electric wire rope hoist and trolleys can be mounted overhead and fitted with monorails or act as the lifting unit for other machines, including: cranes (bridge, gantry, job, etc.) monorail and double girder. 3 The DRH series electric wire rope hoists and relative electric trolleys are made with modular components. This allows multiple standardised or special executions to be made quickly and inexpensively, and most importantly, safely. To guarantee maximum use of the hook run and minimum overall lateral dimensions of the hoist body, the basic components, (motor, gear box and drum) are assembled in a coaxial line, with high strength bolted connections. Each connection can be inspected and has self-locking safety nuts. The drum on the side opposite the gear motor can be connected (upon request) to a cycle counter, selectors, limits switches, encoders, etc. In addition, since it is perfectly symmetrical in the special execution with right and left threading, two gear motors can be installed doubling the lifting speed but maintaining the same capacity and vertical lifting axis. This solution is particularly suited for configurations with large hook runs. The construction uses the most advanced technology and highly industrialised manufacturing processes to build totally reliable machines with economies of scale. 4 THE DRH SERIES ELECTRIC WIRE ROPE HOIST RANGE IS CREATED IN: 4 basic sizes, DRH 1-2-3-4, for capacities from 800 to 50,000 kg, in the FEM (ISO) service groups 1Bm (M3) -1Am (M4) 2m (M5) - 3m (M6). 8/2.6 or 12/4 m/min. for 2 falls wire rope hoists 4/1.3 or 6/2 m/min. for 4 falls wire rope hoists 2.7/0.9 or 4/1.3 m/min. for 6 falls wire rope hoists 2/0.7 or 3/1 m/min. for 8 falls wire rope hoists One lifting speed created with a 4 pole motor: 8 or 12 m/min. for 2 falls wire rope hoists 4 or 6 m/min. for 4 falls wire rope hoists 2.7 or 4 m/min. for 6 falls wire rope hoists 2 or 3 m/min. for 8 falls wire rope hoists IN FIXED EXECUTION This is the universal, basic configuration, with fixing eyebolts that allow any version of DRH hoist fixing on a frame or to be adapted in a suspended execution. ELECTRIC MONORAIL TROLLEYS, TYPE DST/N/S The DRH hoist is supplied in suspended execution with the normal trolley or articulated trolley for curved beams, it runs on a single beam and is operated electrically. PROTECTION AND INSULATION OF ELECTRICAL PARTS With 2 speeds with 1/3 ratio created with a 4/12 pole motor: 5 standard versions with: short (C), normal (N), long (L) or extra long (X1) and (X2) drum lengths, for hook runs from 4 to 58 m. ELECTRIC MONORAIL TROLLEY, TYPE DST/R In this configuration the DRH hoist is supplied in low headroom execution for maximum height of lift. It is compact and runs on a single beam; it is operated electrically. DOUBLE GIRDER TROLLEY, TYPE DRT The DRH hoist can be fitted longitudinally on the frame or suspended, or in transversal execution, on the trolley, which runs on two beams and is operated electrically. The two girder trolley execution allows the maximum hook run of the hoist. NOMINAL WORKING CONDITIONS Hoist and trolley motors: IP55 protection – “F” insulation class Operating temperature: minimum -10°C; maximum +40°C Maximum relative humidity: 80% Motor brake IP23 Maximum altitude 1000 m above sea level Limit switch: IP65 minimum protection Maximum insulation voltage 500 V The hoist must be installed in a well ventilated ambient, free from corrosive fumes (acidic fumes, saline mist, etc.). Cables: IEC 20/22 II Maximum insulation voltage 450/750 V NOISE LEVEL ELECTRICAL POWER SUPPLY DRH electric rope hoists are designed to be supplied with AC electrical current with three phase voltage: 400 V - 50Hz in accordance with IEC 38-1. Non-standard voltages and frequencies are available upon request. The sound pressure level emitted by the hoist when fully loaded is always less than 80 dB (A). The incidence of environmental characteristics such as the transmission of sound through metallic structures, reflection caused by combined machines and walls, is not included in the indicated level. 5 THE HOIST IN DETAIL DESIGN AND CONSTRUCTION 15 9 10 6 7 14 5 4 11 8 12 13 2 3 1 6 1. ELECTRIC MOTOR FOR LIFTING 8A/9A PULLEY AND ANCHORAGE SUPPORT - Asynchronous, three-phase, self-braking with tapered motor. Minimum protection IP 55 – Class F insulation. It has thermal probes for protection against overloading. - DRH4 motor, 24 kW cylindrical, asynchronous and three phase. Used in the 6 and 8 rope fall versions, it is composed of an electric welded metal structure and is equipped with a connection plate to be positioned on the double girder trolley. It is fitted with return pulleys made on carbon steel with a mechanically grooved rim and turns on permanently lubricated ball bearings. The overload device is positioned between the support plates on the swinging beam. 2. LIFTING BRAKE - The conical brake is fitted with asbestos free lining. The brake block, which has a fan that guarantees cooling of the brake and the motor, moves axially with the motor shaft and the braking function is activated automatically if the energy supply fails. [RES. 1.2.3 – 4.1.1.6 c) - Annex I Machinery Directive]. - DRH4 24 kW electromechanical brake. 3. COUPLING This creates the connection between the self-braking motor and the gear box, allowing perfect axial sliding of the motor shaft. 10. OVERLOAD DEVICE All DRH series electric rope hoists have an overload device with a threshold level microswitch. [RES. 4.2.1.4 - Annex I Machinery Directive]. The electromechanical overload device, constantly measures and checks the value of the load and the dynamic and inertial effects due to its movement. When the set values are exceeded the microswitch of the device starts by opening the control circuit of the hoist motor control device. 11. WEDGE ANCHORAGE 4. GEAR BOX Coaxial, with three stages of reduction, with cylindrical gears made of thermally treated, highly resistant steel, helicoidal teeth. Dimensioned and made to withstand the phenomena of stress and wear for life in relation to the normal FEM service group. [RES. 4.1.2.3 - Annex I Machinery Directive]. The whole machine is mounted on ball bearings lubricated for life in an oil bath. 5. DRUM The drum in steel casing, is mechanically grooved and supported by the flange of the gear box and the equipment side flange, with hubs with rotating broached holes on permanently lubricated bearings. The drum is dimensioned based on the standards ISO 4308-1:2003 and UNI 9466:1994 as well as the FEM rules 9.661/86. The drum support flanges are fitted with steel cylindrical pins to secure the components which suspend and support the hoist. Mechanically machined seats support the anchorage crossheads and the return pulley. The connection between the two casings is made with bolted stay bolts. 6. ROPE GUIDE This has a threaded ring made of spheroidal cast iron and allows excellent winding of the rope on the drum. [RES. 4.1.2.4 – Annex I Machinery Directive]. An elastic system automatically registers any play or wear. The rope guide is equipped with sliding backlash arms made of brass, which, by acting on the hoist stay bolts, function as raise and lower limit switches. 7. LIFTING LIMIT SWITCH This is a safety component which limits the run of the hook, both raising and lowering, in an emergency. [RES. 4.1.2.6 a) Annex I Machinery Directive]. It is composed of two precision microswitches which operate according to the “positive slow opening” principle and work on the auxiliary circuit of the hoist motor control device. 8. PULLEY ASSEMBLY Used in versions with 4 rope falls, and supported by two pivots which allow it to be oriented based on the vertical axis of the rope. It is equipped with a return pulley made of carbon steel with mechanically grooved rim and turns on permanently lubricated ball bearings. 9. ANCHORAGE CROSSHEAD Used in versions with 2 and 4 rope falls, and supported by two pivots which allow it to be oriented based on the vertical axis of the rope. The overload device is located between the plates of the beam. The anchorage is made of spheroidal cast iron. The minimum coefficient of utilisation is in compliance with the FEM rule 9.661/86. The rope is secured with a wedge which keeps it from unwinding. 12. ROPE This is made of flexible steel, highly resistant to strain and wear. The minimum coefficient of utilisation has been selected to comply with the ISO standard 4308-1:2003. Non-twist ropes are used on DRH hoists with 2 falls and long (L) and extra long, 1st size (X1) drums, and on 2 and 4 fall hoists with extra long, 2nd size (X2) drums. 13. HOOK BLOCK AND HOOK The return pulley is made of carbon steel with mechanically grooved rim. It rotates on bearing which are permanently lubricated. The load hook is made of highly resistant drop forged steel and is mounted on a swinging cross beam. It rotates on a thrust bearing and has a safety device to prevent unhooking. [RES. 4.1.2.6 Annex I Machinery Directive]. 14. FRAME FOR ELECTRICAL CONNECTIONS Supplied upon request. It has cable intake and allows the wiring of all the connections of the electrical equipment of the hoist and electric travel trolley, if present. The compartment for the electrical connections and/or any other low voltage control equipment, is closed with a shock resistant thermoplastic cover, IP 55 protection. 15. LOW VOLTAGE CONTROLS When the hoist is supplied complete with electric controls, the the raise and lower and/or right and left functions of the trolley are activated by electrical equipment which includes: The transformer for the low voltage control circuits. The main contactor and contactors/reversing contactors for controlling the motors. The fuses for protecting the motors and transformer. The terminal board for connections of the auxiliary and power circuits. The components are mounted on a hinged panel and fixed in a compartment located on the side opposite the motor. The controls are activated by a push-button panel supplied in AC at low voltage. The push-button panel is ergonomically shaped, watertight and made of self-extinguishing, shock resistant, thermoplastic material. Its protection level is IP 65. The emergency stop [RES. 1.2.4.3 - Annex I Machinery Directive], is activated by voluntarily pushing the mushroom shaped button, which starts the control circuit [RES. 1.2.3 - Annex I Machinery Directive]. The push-button panel is connected to the electrical equipment by a multipolar electrical cable with break-resistant metallic cores. 7 TROLLEYS DESIGN AND CONSTRUCTION 8 MONORAIL ELECTRIC TROLLEY, TYPES DST/N - S - R NORMAL ARTICULATED – LOW HEADROOM These are normally composed of an idler unit and drive unit, each equipped with two wheels made of mechanically machined pressed steel and mounted on permanently lubricated ball bearings. The wheels of the drive unit are opposing, have a crown gear wheel and are connected to each other by a transmission bar in the normal (N) and low headroom (R) versions. The articulated version (S), is equipped with a double gear motor, both of which directly give the wheels the movement. The steel supporting plates have anti-derailment and anti-drop systems [RES. 4.1.2.2 – Annex I Machinery Directive] and rubber buffers. Travel is assured by one or two self-braking motors with tapered motor, progressive start up and braking, one or two speeds and one of two offset gear motors with gears with helicoidal teeth which are permanently lubricated in an oil bath. ELECTRIC TROLLEY, DOUBLE GIRDER, TYPE DRT The wheels, two of which are driven and two idler, are supported by a steel frame. The wheels, pressed from carbon steel, rotate on permanently lubricated ball bearings. The double girder trolley is equipped with devices to avoid derailment and dropping [RES. 4.1.2.2 – Annex I Machinery Directive] and rubber buffers. Activation of the traverse is assured by a self-braking motor with tapered motor, progressive start up and braking, one or two speeds and an offset gear motor with gears with helicoidal teeth which permanently lubricated in an oil bath. They confer the movement to the drive wheels by a transmission bar. The hoist can be lifted on the top of the trolley or can be suspended or transversal. TRAVERSE LIMIT SWITCHES Upon request all trolleys can be supplied complete with limit switches [RES. 4.1.2.6 a) - Annex I Machinery Directive]. TOWING ARM ELECTRIC TROLLEY, NORMAL MONORAIL, TYPE DST/N In the normal version the trolley has supporting bars with circular cross-sections that support the hoist by hinge and pin suspensions. The drive and idler plates can be adjusted along the bars in relation to the width of the running beam and are complete with brackets fitted with bolted joints. Both units, drive and idler, are connected to each other with strengthening plates. A towing arm is available upon request for all trolley types, adjustable in all directions, to connect the trolley/hoist to the electricity supply and prevent breakage of the conductors. OSCILLATING BRACKET FOR HOISTS MOUNTED ON A DST/N TROLLEY Available upon request to allow the hoist to oscillate in relation to the vertical axis of the running beam. ELECTRIC TROLLEY, MONORAIL, REDUCED HEADROOM, TYPE DST/R In the low headroom version the trolley has supporting bars with a circular cross-section that support the hoist in standing position. The drive and idler plates are sliding and can be adjusted along the bars in relation to the width of the running beam with brackets fitted with bolted joints. The trolley has a counterbalance on the supporting bar with circular cross-section to balance the eccentric weight of the hoist. ELECTRIC TROLLEY, MONORAIL, ARTICULATED, TYPE DST/S In the articulated version the trolley has supporting bars with crosssections and brackets with hinged joints which support the hoist. The drive and idler plates are sliding and can be adjusted along the bars in relation to the width of the running beam and are fitted with bolted joints. Both drive units are opposing on the same bar and are independent from the idler units. 9 PERFECTLY UP-TO-DATE ARIANNA: THE SOFTWARE THAT GUIDES MANUFACTURERS IN THEIR SELECTION OF COMPONENTS TO MANUFACTURE BRIDGE CRANES. 10 MAIN FEATURES Guided selection of the more appropriate Donati products for manufacturing bridge cranes, based on the structural and mechanical requirements of the intended use environment. By entering the following inputs: 1) Capacity – Gauge – ISO class and Configuration (Monorail – Double Girder) 2) Selection of hoist type 3) Selection of trolley type 4) Type of Beam material, desired camber (from 1/600 to 1/1000) 5 Selection of the Electrical Control System specifications. The following outputs are obtained: Beam type (Box Beam or HE Beam) with relative dimensions and static specifications Head type and Gear Motor type based on speed Layout diagram of the installation List of data and codes with relative price list prices Possibility of creating a quotation directly in word format. Possibility of printing the layout. 11 STANDARDS AND CERTIFICATIONS DESIGN AND CONSTRUCTION Donati Sollevamenti S.r.l.’s continuous focus on quality is not just seen in its careful designing, responsible choices and constant testing of materials, production phases and finished product. It involves the whole company through its quality assurance system which has been in place since 1993 and governs and controls the life of the entire company. The integrity in the design and production of all Donati products would not be complete without the careful consideration of the international regulatory framework and standards which are a guarantee of safety for the customer and user. In this light we recommend reading the CSA homologation of DRH rope hoists and relative accessories and trolleys built in a special execution for the North American market. The hoists and their trolleys are designed and manufactured taking into consideration the “Essential Safety Requirements” in Annex I of the EU Machinery Directive 2006/42/EC and are placed on the market and are placed on the market and EC Declaration of Conformity, as per Annex IIA of the same Directive. In addition, DRH series hoists and their trolleys comply with the following Directives: LOW VOLTAGE DIRECTIVE 2006/95/EC ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 2004/108/EC 12 REFERENCE NORMATIVE FRAMEWORK The design and construction of DRH series electric wire rope hoists the following technical standards and rules were taken into consideration: EN ISO 12100:2010 “Fundamental concepts, general design principles” EN ISO 13849-1:2008 “Safety-related parts of control systems” EN 12077-2:2008 “Limiting and indicating devices” EN 13001-1:2009 “General design – Part 1: General principles and requirements” EN 14492-2:2009 “Power driven winches and hoists – Part 2: Power driven hoists” EN 60204-32:2009 “Safety of the electrical equipment of lifting machines” EN 60529:1997 “IP enclosure (IP Codes)” ISO 4301-1:1988 “Classification of lifting equipment. General” ISO 4308-1:2003 “Selection of wire ropes – General” DIN 15401 “Choice of lifting hooks” UNI 9466:1994 “Shell drum. Design requirements” FEM 1.001/98 “Rules for the design of lifting equipment” FEM 9.511/86 “Mechanisms classification” FEM 9.661/86 “Dimensions and designs of rope reeving components” FEM 9.683/95 “Selection of lifting and traverse motors” FEM 9.755/93 “Periods of safe work” FEM 9.761/93 “Lifting force limiters” FEM 9.941/95 “Control symbols“ OPERATING LIMITS, OPERATING CONDITIONS AND LIFE SPAN Correctly determine the operating limits of the hoist in order to ensure correct operation and duration as well as complete compliance of the operating system with the work for which it is intended. AVERAGE DURATION OF DAILY OPERATION For LIFTING operations the average duration of operation is calculated as follows: Tm (hours) = (AHR x C/h x Rt) / (30 x S) The ISO standard 4301-1:1988 and FEM rule 9.511/86 make is possible to classify electric rope hoists based on their use and the parameters necessary for determining the limits of use are the following: Running time Actual hook run This is determined by the heaviest load to be lifted ! The nominal lifting capacity of the hoist must be >− the actual lifting capacity. Lifting capacity = kg This is the average of the actual runs of the load. Hoist running time in a whole day. hook travel ACTUAL LIFTING CAPACITY ascent THE STATE OF STRESS pause descent pause time cycle (max. 10 min) The state of stress is evaluated considering the average entity of the loads lifted and is ascribable to one of the four spectrums load shown below which determine the type of service. 2) Medium 1) Light Rt = hours AHR = m Cycles per hour Lifting speed C/h = N° S = m/min It is the number of complete ascents and descents carried out in an hour. It is the distance covered by the load in a minute. Tm (hours) = (AAR x C/h x Rt) / (30 x S) load (%) load (%) For TRAVEL operations the average duration of operation is calculated as follows: Hoists which rarely lift maximum loads but mainly reduced loads. Hoists which lift approximately the same number of maximum, medium and reduced loads. 3) Heavy 4) Heavy Running time Actual average run Rt = hours AAR (m) = L/2 It is the average length L of the trolley running beam. It is the running time of the trolley in a day. load (%) trolley travel time (%) load (%) time (%) right pause left pause time cycle (max. 10 min) time (%) time (%) Hoists which frequently lift the maximum load but normally medium loads. Hoists which regularly lift loads approximately equal to the maximum load. Cycles per hour Travel speed C/h = N° S = m/min It is the number of complete runs (right and left) carried out in an hour. It is the distance covered by the trolley in a minute of continuous running. 13 SELECTION OF THE LIFTING EQUIPMENT According to the type of use, that determines the stress level and calculation of average daily use time, for lifting and/or travelling, the following table can be used to classify the group and the related mechanisms and select the type of hoist in relation to the capacity. Once the type of hoist is identified, it is important to check the related life in terms of hours of service and total number of cycles in 10 years of operation. LIFE SPAN OF THE LIFTING EQUIPMENT: The overall life span of the lifting equipment is determined from the stress level, real hours of operation of each mechanism and the number of operating cycles of the complete machine. The operating hours and the number of cycles, which depends on the lifting equipment FEM/ISO service group classification, are conventionally expected to allow safe use for a period of 10 years. Thus, after 10 years, the machine may have finished its expected life span, i.e. completed the available operating cycles, related to its specific service group. For this reason, when the 10th year has finished the lifting equipment SHOULD NOT be used unless it is inspected by DONATI SOLLEVAMENTI S.r.l. or by expert technicians assigned for this purpose, aimed at checking if the equipment still has some remaining working life and is therefore able to operate safely for an additional period of time, or should undergo a general overhaul. For example: Capacity = 6300 kg Level of stress = 2) Medium Load Actual hook run = AHR 2.5 M N° of cycles per hour = C/h 8 Daily running time = Rt 8 h Lifting speed = S 4 m/min (4/1 rope falls) N° of working days per year = D/y 220 1) Calculation of the average daily running time: Tm (hours) = (AHR x C/h x Rt) / (30 x S) = (2.5 x 8 x 8) / (30 x 4) = 1.33 h In the table on page 15, in relation to the Capacity (6300 kg), at the medium level of stress (2) and at the average duration of daily operation (Tm = 1.2 h) it is possible to determine the rope hoist, with 4/1 rope falls, which is: Service Group FEM 1Am – Type DRH 24L1• M 2) Test of life span: Hours of operation in 10 years Tm x D/y x 10 years = 1,33 x 220 x 10 = 2933 (hours) < of the 3200 (maximum hours possible) OK N° operating cycles in 10 years C/h x Rt x D/y x 10 years = 8 x 8 x 220 x 10 = 140800 (cycles) < of the 250000 (maximum cycles possible) OK The classification of the hoist service group is shown on the machine plate affixed to it. DONATI SOLLEVAMENTI S.r.l. guarantees the safe use of the DRH wire rope hoist for the entire duration of its expected lifespan, only if used in compliance with the parameters corresponding to the service group and subject to correct, regular maintenance. Classification and limits of use of the lifting equipment electromechanisms Hoist mechanisms Meccanismi del Carrello Two speed double polarity motors Temporary use Intermittent use as per FEM rule 9.683/95 Use based on the stress level (type of duty) Tm = Average duration of daily operation (hours) Life span of the mechanisms in 10 years of operation (hours) 1) Light N° max of operating cycles in 10 years of operation (Σ cycles) Tm = Average duration of daily operation (hours) Life span of the mechanisms in 10 years of operation (hours) 2) Medium N° max of operating cycles in 10 years of operation (Σ cycles) Tm = Average duration of daily operation (hours) Life span of the mechanisms in 10 years of operation (hours) 3) Heavy N° max of operating cycles in 10 years of operation (Σ cycles) Tm = Average duration of daily operation (hours) Life span of the mechanisms in 10 years of operation (hours) 4) Heavy N° max of operating cycles in 10 years of operation (Σ cycles) as per ISO standard 4301-1 Service group of lifting and travelling mechanisms as per FEM rule 9.511 14 Max n° of start-ups per hour (A/h) Tm = Average duration of daily operation (hours) Ratio of intermittence (RI%) Maximum n° of start-ups per hour (A/h) Maximum n° of cycles per hour (C/h) Ratio of intermittence (RI%) Maximum n° of start-ups per hour (A/h) Maximum n° of cycles per hour (C/h) Operation time at main speed (min) Operation time at low speed (min) Maximum n° of start-ups per hour (A/h) Main speed Low speed Main speed Low speed ≤2 3200 250x103 ≤1 1600 125x103 ≤ 0,5 800 63x103 ≤ 0,25 400 32x103 ≤4 6300 500x103 ≤2 3200 250x103 ≤1 1600 125x103 ≤ 0,5 800 63x103 ≤8 12500 100x104 ≤4 6300 500x103 ≤2 3200 250x103 ≤1 1600 125x103 M3 1Bm M4 1Am M5 2m 25 150 25 20 120 20 15 2,5 10 ≤ 16 > 16 > 16 25000 50000 100000 200x104 400x104 > 4x106 ≤8 ≤ 16 > 16 12500 25000 50000 100x104 200x104 400x104 ≤4 ≤8 ≤ 16 6300 12500 25000 500x103 100x104 200x104 ≤2 ≤4 ≤8 3200 6300 12500 250x103 500x103 100x104 M6 3m M7 4m M8 5m 30 40 50 60 60 180 240 300 360 360 30 40 50 60 60 25 30 40 50 60 150 180 240 300 > 360 25 30 40 50 > 60 15 30 30 60 > 60 3 3,5 4 5 6 10 10 10 10 10 1/3 (33,3% of the total n° of start-ups per hour) 2/3 (66,7% of the total n° of start-ups per hour) 2/3 (66,7% of the average duration of daily operation) 1/3 (33,3% of the average duration of daily operation) IDENTIFICATION OF THE HOIST AND RELATIVE TROLLEYS Rope fall configuration → ( single-grooved drum ) Capacity kg Abbreviation gear box capacity L V L V L V L V L V L V L V L V L V L V L V L V L V L V L V L V L V L V L V D D E E F F G G H H I I J J K K L L M M N N O O P P Q Q R R S S T T U U V V 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 2500 3200 3200 4000 4000 5000 5000 6300 6300 8000 8000 10000 10000 12500 12500 16000 16000 20000 20000 25000 25000 32000 32000 40000 40000 50000 50000 8 falls ( 8/1 ) 6 falls ( 6/1 ) 4 falls ( 4/1 ) 2 falls ( 2/1 ) DRH type in FEM group (ISO) DRH type in FEM group (ISO) DRH type in FEM group (ISO) DRH type in FEM group (ISO) 1Bm (M3) 1Am (M4) 2m (M5) 1Am (M4) 2m (M5) 1Bm (M3) 1Am (M4) 2m (M5) 14L2•H 14V2•H 14L1•I 14V1•I 14L1•J 14V0•J 14L1•K 24V1•K 24L1•L 24V0•L 24L1•M 34L1•N 34V1•N 34L1•O 34V0•O 34L1•P 44V1•P 44L1•Q 36L2•Q 44V0•Q 38L2•R 36L1•R 38L1•S 46L1•T 46S1•T 48L1•U 48S1•U 46L2•S 46S2•S 46L2•T 44L0•S 44L1•R 44S1•R 44M1•S 24V2•I 14L2•J 24V2•J 24L2•K 34V2•K 24L2•L 34V2•L 34L2•M 34V2•M 34L2•N 44V2•N 34L2•O 44V2•O 44L2•P 44S2•P 44L2•Q 44S2•Q 44L2•R 3m (M6) 14L3•E 14V3•E 14L3•F 14V3•F 14L3•G 14V3•G 14L3•H 24V3•H 14L3•I 24V3•I 24L3•J 34V3•J 24L3•K 34V3•K 34L3•L 34V3•L 34L3•M 44V3•M 34L3•N 44V3•N 44L3•O 44S3•O 44L3•P 44S3•P 1Am (M4) 2m (M5) 12L2•E 12V2•E 12L1•F 12V1•F 12L1•G 22V2•F 12L2•G 22V2•G 22L2•H 32V2•H 22L2•I 32V2•I 32L2•J 32V2•J 32L2•K 42V2•K 32L2•L 42V2•L 42L2•M 12L1•H 22V1•H 22L1•I 22L1•J 32L1•K 32V1•K 32L1•L 32L1•M 42V1•M 42L1•N 3m (M6) 12L3•D 12V3•D 12L3•E 22V3•E 12L3•F 22V3•F 22L3•G 32V3•G 22L3•H 32V3•H 32L3•I 32V3•I 32L3•J 42V3•J 32L3•K 42V3•K 42L3•L 42L3•M 42L2•N 42L1•O 42S1•O 48L2•U 48L0•V 48S0•V DRH Size 1 DRH Size 2 DRH Size 3 DRH Size 4 DRH 4 cylindrical motor KEY AND EXAMPLE OF IDENTIFYING CHARACTERISTICS OF THE HOISTS AND TROLLEYS USING CODES DRH Hoist Size: 1-2-3-4 N° of rope 2 = 2 falls 4 = 4 falls 6 = 6 falls 8 = 8 falls falls: (2/1) (4/1) (6/1) (8/1) Gear box type: ©M-Cylindrical = Slow 4 m/min with 4/1 falls ©S-Cylindrical = Fast 3 m/min with 8/1 falls 4 m/min with 6/1 falls 6 m/min with 4/1 falls 12 m/min with 2/1 falls L = Slow 2 m/min with 8/1 falls 2.7 m/min with 6/1 falls 4 m/min with 4/1 falls 8 m/min with 2/1 falls V = Fast 6 m/min with 4/1 falls 12 m/min with 2/1 falls 0 1 2 3 = = = = 1 1 2 3 DST TROLLEY Hoist speed: S =1 Speed W =2 Speed Capacity abbreviation: L = 5000 kg Type of drum: N = Standard C = Short L = Long 1 = Extra long - X1 (1 st size) 2 = Extra long - X2 (2nd size) X = Special Configuration type Monorail suspended Size: 1-2-3-4 Trolley speed: m/min E=8 F = 10 G = 16 H = 20 D = 16/4 W = 20/5 Version: A = Normal B = Low headroom C = Articulated D = Oscillating DRT Trolley Configuration type Double girder Size: 1-2-3-4 Gauge: mm A = 1000 B = 1200 C = 1400 D = 2240 E = 2800 X = Special Version: 0 = Hoist on trolley S =Suspended T = Transversal Trolley speed: m/min E=8 F = 10 G = 16 H = 20 D = 16/4 W = 20/5 Bm (M3) Am (M4) m (M5) m (M6) 15 TECHNICAL SPECIFICATIONS AND DATA Capacity (kg) 800 1000 1250 1600 2000 2500 3200 4000 5000 16 Data of DRH electric wire rope hoists Hoist FEM group DHR type 3m 3m 3m 3m 2m 3m 2m 3m 3m 3m 1Am 3m 1Am 2m 3m 3m 3m 1Am 2m 3m 2m 3m 2m 3m 2m 3m 1Am 2m 3m 1Am 2m 3m 1Am 3m 1Am 2m 3m 1Am 2m 3m 2m 3m 1Am 1Bm 2m 3m 2m 3m 1Am 2m 3m 2m 3m 1Am 2m 3m 1Am 2m 3m 1Am 2m 3m 1Am 2m 3m 1Am 1Bm 2m 3m 2m 3m 1Am 2m 3m 2m 12L3• D 12V3•D 14L3•E 14V3•E 12L2•E 12L3•E 12V2•E 22V3•E 14L3•F 14V3•F 12L1•F 12L3•F 12V1•F 22V2•F 22V3•F 14L3•G 14V3•G 12L1•G 12L2•G 22L3•G 22V2•G 32V3•G 14L2•H 14L3•H 14V2•H 24V3•H 12L1•H 22L2•H 22L3•H 22V1•H 32V2•H 32V3•H 14L1•I 14L3•I 14V1•I 24V2•I 24V3•I 22L1•I 22L2•I 32L3•I 32V2•I 32V3•I 14L1•J 14V0•J 14L2•J 24L3•J 24V2•J 34V3·J 22L1•J 32L2•J 32L3•J 32V2•J 42V3•J 14L1•K 24L2•K 24L3•K 24V1•K 34V2•K 34V3•K 32L1•K 32L2•K 32L3•K 32V1•K 42V2•K 42V3•K 24L1•L 24V0•L 24L2•L 34L3•L 34V2•L 34V3•L 32L1•L 32L2•L 42L3•L 42V2•L Speed at 50 Hz (m/min) 1 Speed 2 Speed 8 12 4 6 8 8 12 12 4 6 8 8 12 12 12 4 6 8 8 8 12 12 4 4 6 6 8 8 8 12 12 12 4 4 6 6 6 8 8 8 12 12 4 6 4 4 6 6 8 8 8 12 12 4 4 4 6 6 6 8 8 8 12 12 12 4 6 4 4 6 6 8 8 8 12 8/2,6 12/4 4/1,3 6/2 8/2,6 8/2,6 12/4 12/4 4/1,3 6/2 8/2,6 8/2,6 12/4 12/4 12/4 4/1,3 6/2 8/2,6 8/2,6 8/2,6 12/4 12/4 4/1,3 4/1,3 6/2 6/2 8/2,6 8/2,6 8/2,6 12/4 12/4 12/4 4/1,3 4/1,3 6/2 6/2 6/2 8/2,6 8/2,6 8/2,6 12/4 12/4 4/1,3 6/2 4/1,3 4/1,3 6/2 6/2 8/2,6 8/2,6 8/2,6 12/4 12/4 4/1,3 4/1,3 4/1,3 6/2 6/2 6/2 8/2,6 8/2,6 8/2,6 12/4 12/4 12/4 4/1,3 6/2 4/1,3 4/1,3 6/2 6/2 8/2,6 8/2,6 8/2,6 12/4 Motor power (kW) 1 Speed 2 Speed 3 3 3 3 3 3 3 5 3 3 3 3 3 5 5 3 3 3 3 5 5 10 3 3 3 5 3 5 5 5 10 10 3 3 3 5 5 5 5 10 10 10 3 3,5 3 5 5 10 5 10 10 10 16 3 5 5 5 10 10 10 10 10 10 16 16 5 5,5 5 10 10 10 10 10 16 16 3/1 3/1 3/1 3/1 3/1 3/1 3/1 5/1,65 3/1 3/1 3/1 3/1 3/1 5/1,65 5/1,65 3/1 3/1 3/1 3/1 5/1,65 5/1,65 10/3,3 3/1 3/1 3/1 5/1,65 3/1 5/1,65 5/1,65 5/1,65 10/3,3 10/3,3 3/1 3/1 3/1 5/1,65 5/1,65 5/1,65 5/1,65 10/3,3 10/3,3 10/3,3 3/1 3,5/1,1 3/1 5/1,65 5/1,65 10/3,3 5/1,65 10/3,3 10/3,3 10/3,3 16/5,3 3/1 5/1,65 5/1,65 5/1,65 10/3,3 10/3,3 10/3,3 10/3,3 10/3,3 10/3,3 16/5,3 16/5,3 5/1,65 5,5/1,8 5/1,65 10/3,3 10/3,3 10/3,3 10/3,3 10/3,3 16/5,3 16/5,3 C Hook run (m) with drum (1) N L X1 X2 8 8 4 4 8 8 8 10 4 4 8 8 8 10 10 4 4 8 8 10 10 10 4 4 4 5 8 10 10 10 10 10 4 4 4 5 5 10 10 10 10 10 4 4 4 5 5 5 10 10 10 10 12 4 5 5 5 5 5 10 10 10 10 12 12 5 5 5 5 5 5 10 10 12 12 12 12 6 6 12 12 12 14 6 6 12 12 12 14 14 6 6 12 12 14 14 14 6 6 6 7 12 14 14 14 14 14 6 6 6 7 7 14 14 14 14 14 6 6 6 7 7 7 14 14 14 14 16 6 7 7 7 7 7 14 14 14 14 16 16 7 7 7 7 7 7 14 14 16 16 45 45 19 19 45 45 45 43 19 19 45 45 45 43 43 19 19 45 45 43 43 47 19 19 19 18 45 43 43 47 47 19 19 19 18 18 43 43 47 47 47 19 19 19 18 18 19 43 47 47 47 58 19 18 18 19 19 47 47 47 47 58 58 18 18 18 19 19 19 47 47 58 58 24 24 9 9 24 24 24 26 9 9 24 24 24 26 26 9 9 24 24 26 26 28 9 9 9 10 24 26 26 28 28 9 9 9 10 10 26 26 28 28 28 9 9 9 10 10 10 26 28 28 28 32 9 10 10 10 10 10 28 28 28 28 32 32 10 10 10 10 10 10 28 28 32 32 34 34 14 14 34 34 34 34 14 14 34 34 34 34 34 14 14 34 34 34 34 37 14 14 14 14 34 34 34 37 37 14 14 14 14 14 34 34 37 37 37 14 14 14 14 14 14 34 37 37 37 45 14 14 14 14 14 14 37 37 37 37 45 45 14 14 14 14 14 14 37 37 45 45 Rope (1) N° Ø / Type of falls (mm) 2/1 2/1 4/1 4/1 2/1 2/1 2/1 2/1 4/1 4/1 2/1 2/1 2/1 2/1 2/1 4/1 4/1 2/1 2/1 2/1 2/1 2/1 4/1 4/1 4/1 4/1 2/1 2/1 2/1 2/1 2/1 2/1 4/1 4/1 4/1 4/1 4/1 2/1 2/1 2/1 2/1 2/1 4/1 4/1 4/1 4/1 4/1 4/1 2/1 2/1 2/1 2/1 2/1 4/1 4/1 4/1 4/1 4/1 4/1 2/1 2/1 2/1 2/1 2/1 2/1 4/1 4/1 4/1 4/1 4/1 4/1 2/1 2/1 2/1 2/1 7B (7B) 7B (7B) 7B (7B) 7B (7B) 7B (7B) 7B (7B) 7B (7B) 8M (8B) 7B (7B) 7B (7B) 7B (7B) 7M (7A) 7B (7B) 9B (9B) 8M (8B) 7B (7B) 7B (7B) 7M (7A) 7M (7A) 8A (8A) 9B (9B) 12M (12A) 7B (7B) 7B (7B) 7B (7B) 8M (8B) 7A (7A) 9B (9B) 8A 9B (9B) 13B (13B) 12M (12A) 7B (7B) 7M (7A) 7B (7B) 9B (9B) 8M (8B) 9M (9A) 9M (9A) 12M (12B) 13B (13B) 12M (12A) 7M (7A) 7M (7A) 7M (7A) 8A (8A) 9B (9B) 12M (12A) 9A (9A) 13B (13B) 12M (12A) 13B (13B) 15M (15A) 7A (7A) 9B (9B) 8A 9B (9B) 13B (13B) 12M (12A) 13B (13B) 13M (13B) 12A (12A) 13B (13B) 16B (16B) 15M (15A) 9M (9A) 9M (9A) 9M (9A) 12M (12A) 13B (13B) 12M (12A) 13M (13A) 13M (13A) 15M (15A) 16B (16B) Type of trolley on the hoist monorail DST - N/R double girder DRT 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 2 1 1 1 1 2 2 1 1 1 2 2 1 1 2 2 2 1 1 1 2 2 3 1 2 2 2 3 1 2 2 2 3 3 2 2 2 2 3 3 2 2 2 3 3 3 2 2 3 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 2 2 2 1 1 1 1 1 2 1 2 2 2 3 1 1 1 1 2 2 2 2 2 2 3 3 1 1 1 2 2 2 2 2 3 3 Capacity (kg) 6300 8000 10000 12500 16000 20000 25000 32000 40000 50000 Data of DRH electric wire rope hoists Hoist FEM group DHR type 1Am 2m 3m 2m 3m 1Am 2m 3m 1Am 1Am 2m 3m 1Am 2m 3m 1Am 2m 1Am 1Bm 2m 3m 2m 3m 1Am 1Am 1Am 2m 3m 1Am 2m 3m 2m 1Am 1Bm 2m 1Am 2m 1Am 1Am 1Am 2m 2m 1Bm 1Am 1Am 2m 2m 1Am 1Am 2m 1Am 1Am 2m 1Bm 1Bm 24L1•M 34L2•M 34L3•M 34V2•M 44V3•M 32L1•M 42L2•M 42L3•M 42V1•M 34L1•N 34L2•N 34L3•N 34V1•N 44V2•N 44V3•N 42L1•N 42L2•N 34L1•O 34VO•O 34L2•O 44L3•O 44V2•O ©44S3•O 42L1•O © 42S1•O 34L1•P 44L2•P 44L3•P 44V1•P © 44S2•P © 44S3•P 36L2•Q 44L1•Q 44V0•Q 44L2•Q © 44S1•Q © 44S2•Q 36L1•R 44L1•R © 44S1•R 38L2•R 44L2•R 44L0•S 38L1•S ©44M1•S 46L2•S ©46S2•S 46L1•T ©46S1•T 46L2•T 48L1•U ©48S1•U 48L2•U 48L0•V © 48S0•V Speed at 50 Hz (m/min) 1 Speed 2 Speed 4 4 4 6 6 8 8 8 12 4 4 4 6 6 6 8 8 4 6 4 4 6 6 8 12 4 4 4 6 6 6 2,7 4 6 4 6 6 2,7 4 6 2 4 4 2 4 2,7 4 2,7 4 2,7 2 3 2 2 3 4/1,3 4/1,3 4/1,3 6/2 6/2 8/2,6 8/2,6 8/2,6 12/4 4/1,3 4/1,3 4/1,3 6/2 6/2 6/2 8/2,6 8/2,6 4/1,3 6/2 4/1,3 4/1,3 6/2 6/2 8/2,6 12/4 4/1,3 4/1,3 4/1,3 6/2 6/2 6/2 2,7/0,9 4/1,3 6/2 4/1,3 6/2 6/2 2,7/0,9 4/1,3 6/2 2/0,7 4/1,3 4/1,3 2/0,7 4/1,3 2,7/0,9 4/1,3 2,7/0,9 4/1,3 2,7/0,9 2/0,7 3/1 2/0,7 2/0,7 3/1 Motor power (kW) 1 Speed 2 Speed 5 10 10 10 16 10 16 16 16 10 10 10 10 16 16 16 16 10 11 10 16 16 24 16 24 10 16 16 16 24 24 10 16 18 16 24 24 10 16 24 10 16 18 10 24 16 24 16 24 16 16 24 16 18 27 5/1,65 10/3,3 10/3,3 10/3,3 16/5,3 10/3,3 16/5,3 16/5,3 16/5,3 10/3,3 10/3,3 10/3,3 10/3,3 16/5,3 16/5,3 16/5,3 16/5,3 10/3,3 11/3,6 10/3,3 16/5,3 16/5,3 24/7,8 16/5,3 24/7,8 10/3,3 16/5,3 16/5,3 16/5,3 24/7,8 24/7,8 10/3,3 16/5,3 18/5,9 16/5,3 24/7,8 24/7,8 10/3,3 16/5,3 24/7,8 10/3,3 16/5,3 18/5,9 10/3,3 24/7,8 16/5,3 24/7,8 16/5,3 24/7,8 16/5,3 16/5,3 24/7,8 16/5,3 18/5,9 27/8,8 C Hook run (m) with drum (1) N L X1 X2 5 5 5 5 6 10 12 12 12 5 5 5 5 6 6 12 12 5 5 5 6 6 6 12 12 5 6 6 6 6 6 – 6 6 6 6 6 – 6 6 6 6 – 6 – – – – – – – – – – 7 7 7 7 8 14 16 16 16 7 7 7 7 8 8 16 16 7 7 7 8 8 8 16 16 7 8 8 8 8 8 4 8 8 8 8 8 4 8 8 8 8 – 8 5 5 5 5 5 3 3 3 3 3 18 19 19 19 24 47 58 58 58 19 19 19 19 24 24 58 58 19 19 19 24 24 24 58 58 19 24 24 24 24 24 15 24 24 24 24 24 15 24 24 10,8 24 24 10,8 24 19 19 19 19 19 13,5 13,5 13,5 13,5 13,5 10 10 10 10 11 28 32 32 32 10 10 10 10 11 11 32 32 10 10 10 11 11 11 32 32 10 11 11 11 11 11 8,8 11 11 11 11 11 8,8 11 11 6 11 11 6 11 10 10 10 10 10 7 7 7 7 7 14 14 14 14 17 37 45 45 45 14 14 14 14 17 17 45 45 14 14 14 17 17 17 45 45 14 17 17 17 17 17 11,5 17 17 17 17 17 11,5 17 17 8 17 17 8 17 14 14 14 14 14 10 10 10 10 10 Rope (1) N° Ø / Type of falls (mm) 4/1 4/1 4/1 4/1 4/1 2/1 2/1 2/1 2/1 4/1 4/1 4/1 4/1 4/1 4/1 2/1 2/1 4/1 4/1 4/1 4/1 4/1 4/1 2/1 2/1 4/1 4/1 4/1 4/1 4/1 4/1 6/1 4/1 4/1 4/1 4/1 4/1 6/1 4/1 4/1 8/1 4/1 4/1 8/1 4/1 6/1 6/1 6/1 6/1 6/1 8/1 8/1 8/1 8/1 8/1 9A (9A) 13B (13B) 12M (12A) 13B (13B) 15M (15A) 13A (13A) 16B (16B) 15A (15A) 16B (16B) 13B (13B) 13M (13B) 12A (12A) 13B (13B) 16B (16B) 15M (15A) 16M (16M) 16M (16M) 13M (13A) 13M (13A) 13M (13A) 15M (15A) 16B (16B) 15M (15A) 16A (16A) 16A (16A) 13A (13A) 16B (16B) 15A (15A) 16B (16B) 16B (16B) 15A (15A) 13A1 16M (16M) 16M (16M) 16M (16M) 16M (16M) 16M (16M) 13A1 16A (16A) 16A (16A) 13A1 16A1(16A) 16A1 13A1(13A1) 16,2A 16A 16A 16A 16A 16A1 16A 16A 16A1 16A1 16A1 Type of trolley on the hoist monorail DST - N/R double girder DRT 2 3 3 3 4 2 3 3 3 3 3 3 3 4 4 3 3 3 3 3 4 4 4 3 3 3 4 4 4 4 4 – 4 4 4 4 4 – 4 4 4 – – – – – – – – – – – – – 1 2 2 2 3 2 3 3 3 2 2 2 2 3 3 3 3 2 2 2 3 3 3 3 3 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 NOTES : (1)The hoists with 2 falls with drum L, X1, X2 and hoists with 4 falls with drum X2 use anti-twist ropes. The type of anti-twist rope is shown in brackets. © DRH4 version with cylindrical motor. Breaking load of ropes ( minimum guaranteed kN ) Hoist type → Ø Rope (mm) → Strength class → Normal (kN) Anti-twist (kN) B 30,4 35,3 DRH 1 Ø7 M 42,1 – DRH 2 Ø8 A 48,1 48,8 M 42,0 46,1 A 61,6 60,5 B 53,1 58,4 DRH 3 Ø9 M 69,6 – Ø 12 A 74,6 76,6 M 121,7 – A 138,7 136,2 Ø 13 B 102,0 121,8 M 142,5 – A 163,4 159,8 Ø 15 A1 154,0 - M 189,7 – A 219,2 212,7 B 176,9 184,4 DRH 4 Ø 16 M A 215,9 236,0 242,1 255,0 A1 268,0 - Ø 16,2 A 296,0 17 Trolley data and motor power ( maximum that can be supplied = kW ) at one and two travel speeds 1 Speed: 16 or 20 m/min (1) 2 Speed: 16/4 or 20/5 m/min (1) 1 Speed: 8 or 10 m/min (1) Electric travel trolley Type - Size DST - N/R Monorail DRT Double girder 1-2 3 4 1 2 3 Reducer ratio with m/min speed 8 10 Trolley motor Type Power 4 pole kW Reducer ratio with m/min speed 16 20 Trolley motor (2) Type Power 2 pole kW Gear box ratio with m/min speed 16/4 20/5 Trolley motor Type Power 2/8 pole kW τ1 τ1 τ1 τ1 τ1 τ1 τ1 τ1 71 - 4 80 - 4 80 - 4 71 - 4 80 - 4 80 - 4 100 - 4 100 - 4 τ1 τ1 τ1 τ1 τ1 τ1 τ1 τ1 71 - 2 80 - 2 80 - 2 71 - 2 80 - 2 80 - 2 100 - 2 100 - 2 τ1 τ1 τ1 τ1 τ1 τ1 τ1 τ1 71 - D 80 - D 80 - D 71 - D 80 - D 80 - D 100 - D 100 - D τ2 τ2 τ2 τ2 τ2 τ2 τ2 τ2 0,16 0,25 0,32 0,16 0,25 0,32 0,63 0,63 τ2 τ2 τ2 τ2 τ2 τ2 τ2 τ2 0,32 0,50 0,63 0,32 0,50 0,63 1,25 1,25 4 NOTES: For combinations with double gear motor see page 35 (1) The lifting and travel speeds and powers of the related motors refer to three-phase voltage with 50Hz frequency. They have to be increased 20% for a frequency of 60Hz. (2) With 2 poles motors per inverter the powers are: 71-2 = 0.5kW; 80-2 = 0.8kW; 100-2 = 2kW DST N/S R POSITION OF THE WHEELS ON THE BEAM FOR ALL DST TROLLEYS Dimensions ØR Max. (mm) Wheel thickness (mm) (mm) i a b DST 1 DST 2 DST 3 DST 4 100 125 160 200 8 12 17 19 35 35 45 50 18 29 34 39 DRT 20 23 35 41 DRT 1 DRT 2 DRT 3 DRT 4 Position of the wheels on the beam for all DST trolleys τ2 τ2 τ2 τ2 τ2 τ2 τ2 τ2 0,40/0,09 0,50/0,12 0,63/0,15 0,40/0,09 0,50/0,12 0.63/0,15 1,25/0,31 1,25/0,31 DIMENSIONS OF DRT WHEELS AND RELATIVE RAILS Dimensions (mm) ØR Whell Rail Wheel (mm) A B C Øe h min. b min. 125 160 200 250 50 55 60 70 15 19 20 20 80 93 100 110 150 190 230 280 30 30 30 40 30 30 40 50 b max 40 45 50 60 Track position of the wheel carts DRT FIXING OF THE DRH WIRE ROPE HOISTS IN SUSPENDED AND STANDING EXECUTION Fixing of 2 and 4 fall hoists in suspended execution: Detail of the hole and connection area of the universal eyebolt Fixing of 2, 4, 6 and 8 fall hoists in standing execution: Detail of the support foot and the connection area of the universal eyebolt (2 and 4 falls) and stay bolts (6 and 8 falls) The universal eyebolt is supplied as a standard. For dimensions I and I1 see the DRH standing/suspended page. The universal eyebolt (2 and 4 falls) or stay bolt (6 and 8 falls) is supplied as a standard. For dimensions I and I1 see the DRH standing/suspended page. N° of rope falls 2/1 - 4/1 6/1 - 8/1 DHR type A A1 B B1 B2 1 2 3 4 3 4 20 22 32 42 32 42 20 22 32 42 32 42 37 42 48 60 48 60 21 31 36 38 36 38 21 31 36 46 - Overall dimensions (mm) B3 B4 35 40 55 70 - 35 40 55 70 - B5 B6 ØF M G 50 55 76 89 48 60 13 13 28 29 - 20 25 35 45 35 45 16x2 20x2,5 24x3 30x3,5 20x2,5 27x3 65 70 93 108 55 57 NOTES – Fixing 2, 4, 6 and 8 fall hoists in standing execution for applications on trolleys not supplied by Donati: • With the universal eyebolt (2 and 4 falls), the headroom of the hoist (H2 DRH dimension) needs to be increased by the dimension “B6” compared to the hoist support surface. • With the stay bolt (6 and 8 falls) the headroom does not need to be increased by the dimension “B6”. 18 OVERALL DIMENSIONS - WEIGHTS DRH SERIES ELECTRIC WIRE ROPE HOISTS WITH 2 AND 4 ROPE FALLS IN STANDING OR SUSPENDED EXECUTION Reactions on the supports, see page 29 S2 = I1 – S3 – S1 * For DRH3 and DRH4 with L.V., dimension P becomes: DRH3 = 330; DRH4 = 360 N° of rope falls DHR type H H1 H2 H3 I 1 2 3 4 ©4 1 2 3 4 ©4 690 820 1090 1390 1390 650 750 1020 1320 1320 460 550 710 920 920 420 480 640 850 850 230 270 380 470 470 230 270 380 470 470 390 445 595 750 750 345 390 540 700 700 250 290 370 460 460 250 290 370 460 460 2/1 4/1 N° of rope falls 2/1 4/1 DHR type I1 1 2 3 4 ©4 1 2 3 4 ©4 400 480 600 722 722 400 480 600 722 722 Drum C R S1 1135 1275 1510 1797 1957 1135 1275 1510 1797 1957 125 160 195 220 220 70 105 130 150 150 S3 I1 95 100 130 170 170 150 180 240 300 300 515 600 740 862 862 515 600 740 862 862 Drum N R S1 1250 1395 1650 1937 2097 1250 1395 1650 1937 2097 185 220 265 290 290 100 135 160 180 180 S3 I1 Drum L R S1 95 100 130 170 170 150 180 240 300 300 890 1000 1260 1422 1422 890 1000 1260 1422 1422 1625 365 1795 410 2170 515 2497 570 2657 570 1625 160 1795 210 2170 240 2497 220 2657 220 Overall dimensions (mm) L L1 320 370 480 600 600 320 370 480 600 600 210 235 290 360 360 210 235 290 360 360 Drum X1 R S1 S3 I1 95 1200 1935 515 100 1260 2055 530 130 1550 2460 680 170 1852 2927 800 170 1852 3087 800 165 1200 1935 230 200 1260 2055 280 270 1550 2460 280 300 1852 2927 310 300 1852 3087 310 95 100 130 170 170 165 200 270 300 300 1530 1530 1940 2352 2352 1530 1530 1940 2352 2352 S3 I1 N P Q S4 480 525 705 855 1015 480 525 705 855 1015 255 270 205 220 220 255 270 205 220 220 225 260 300 340 340 225 260 300 340 340 28 30 40 45 45 15 19 23 25 25 Drum X2 R S1 2265 2325 2850 3427 3587 2265 2325 2850 3427 3587 680 670 860 1030 1030 300 350 350 410 410 S3 95 100 130 170 170 165 200 270 300 300 Weight (kg) with drum type C N L X1 X2 132 141 160 180 195 215 460 490 565 855 890 1010 910 945 1065 140 150 170 195 205 235 515 540 625 960 1000 1140 1015 1055 1195 180 260 590 1200 1255 200 280 650 1350 1405 200 280 620 1250 1305 220 300 700 1400 1455 ©DRH4 hoist with cylindrical motor. 19 DRH SERIES ELECTRIC ROPE HOISTS WITH 6 AND 8 ROPE FALLS IN STANDING EXECUTION Reactions on the supports, see page 29 N° of rope falls 6/1 8/1 N° of rope falls 6/1 8/1 ©DRH4 20 DHR type H H1 H3 H4 3 4 ©4 3 4 ©4 1435 1665 1665 1435 1665 1665 1055 1195 1195 1055 1195 1195 777 922 922 777 922 922 330 410 410 330 410 410 Overall dimensions (mm) L2 L3 350 355 355 420 455 455 330 360 360 450 556 556 S4 L1 N P 415 470 470 515 570 570 290 360 360 290 360 360 705 855 1015 705 855 1015 205 220 220 205 220 220 DHR type I1 Drum N R S3 I1 Drum L R S3 I1 Drum X1 R S3 I1 Drum X2 R S3 N 3 4 ©4 3 4 ©4 740 862 862 862 862 1650 1937 2097 1937 2097 165 180 180 278 278 1260 1422 1422 1260 1422 1422 2170 2497 2657 2170 2497 2657 165 180 180 225 278 278 1550 1852 1852 1550 1852 1852 2460 2927 3087 2460 2927 3087 165 180 180 225 278 278 1940 2352 2352 1940 2352 2352 2850 3427 3587 2850 3427 3587 165 180 180 225 278 278 595 1070 1125 1110 1165 hoist with cylindrical motor. Weight (kg) with drum type L X1 X2 680 1210 1265 700 1250 1305 710 1420 1475 730 1460 1515 760 1470 1525 780 1510 1565 DST/N/S MONORAIL TROLLEYS FOR DRH ELECTRIC WIRE ROPE HOISTS – 2 (2/1) AND 4 (4/1) ROPE FALL VERSIONS Reactions on the supports, see page 30 DRH series electric wire rope hoists with 2 and 4 rope falls with normal trolley N * For dimensions I1 - S1 - S2 - S3 see page 19 N° of rope falls 2/1 4/1 DHR type Trolley DST N/S C C1 C2 1 2 3 4 ©4 1 2 3 4 ©4 1 1 2 3 3 1 2 3 4 4 140 140 160 275 275 140 160 275 325 325 115 130 45 -55 -55 115 110 -70 -105 -105 340 385 545 580 740 340 365 430 530 690 Overall dimensions (mm) D D1 66 66 75 90 90 66 75 90 102 102 393 393 400 460 460 393 400 460 468 468 E E1 E2 C N Weight (kg) with drum type L 870 1000 1290 1650 1650 830 950 1280 1620 1620 130 130 148 191 191 128 148 191 237 237 180 180 195 255 255 180 195 255 295 295 215 260 575 1120 1175 220 300 775 1415 1470 220 270 600 1155 1210 230 310 810 1455 1510 240 295 675 1270 1325 250 335 880 1590 1645 X1 X2 270 326 750 1480 1535 280 380 996 1800 1855 290 346 826 1650 1705 300 400 1070 1970 2025 © DRH4 hoist with cylindrical motor. N.B.: For the speed, power and position of the wheel see page 18 21 DST/N/S MONORAIL TROLLEYS FOR DRH ELECTRIC WIRE ROPE HOISTS 2 (2/1) AND 4 (4/1) ROPE FALL VERSIONS - ARTICULATED DST/N/S MONORAIL TROLLEYS FOR DRH ELECTRIC WIRE ROPE HOISTS 2 (2/1) AND 4 (4/1) DRH series electric wire rope hoists with 2 and 4 rope falls with articulated trolley S DRH series electric wire rope hoists with 2 and 4 rope falls with articulated trolley S * For dimensions I1 - S1 - S2 - S3 see page 19 Trolley * For dimensions I1 - S1 - S2 - S3 see page 19 N° of rope falls 2/1 4/1 DHR type Trolley DST N/S C3 1 2 3 4 1 2 3 4 1 1 2 3 1 2 3 4 156 156 160 280 156 160 280 327 N.B.: For the speed, power and position of the wheel see page 18 22 Overall dimensions (mm) r min. 1500 1500 1600 * 1600 1500 1600 1600 1800 E3 960 1090 1400 1855 920 1050 1485 1810 DST1N DST2N DST3N DST4N DST1O DST2O DST3O DST4O DST1S DST2S DST3S DST4S Beam specifications table for DST trolleys Min. beam width Max. thickness (mm) (mm) 90 119 135 180 100 135 170 210 100 135 170 210 20 23 35 41 20 23 35 41 20 23 35 41 * DST3S with DRH4 2 rope falls drum X2 Minimum radius = 1800 Min. beam width = minimum beam width required Minimum radius = minimum internal radius required for curved beams Max. thickness = maximum beam flange thickness allowed N = normal; S = articulated ; O = oscillating Min. radius (mm) – – – – – – – – 1500 1600 *1600 1800 DST/R MONORAIL TROLLEYS FOR DRH ELECTRIC WIRE ROPE HOISTS 2 FALL (2/1) AND 4 FALL (4/1) VERSIONS Reactions on the supports, see page 31 DRH series electric wire rope hoists with 2 and 4 rope falls with low headroom trolley R * For dimensions I1 - S1 - S2 - S3 see page 19 N° of rope falls 2/1 4/1 DHR type DST-R trolley D D1 D2 D2 drum (x1-x2) 1 2 3 4 ©4 1 2 3 4 ©4 1 1 2 3 3 1 2 3 4 4 440 485 605 755 755 440 495 625 760 760 230 250 315 395 395 230 265 335 405 405 540 590 655 677 677 540 560 622 630 630 393 420 582 677 677 393 412 547 630 630 Overall dimensions (mm) E1 E1 drum E2 E3 (x1-x2) 140 200 317 352 352 140 195 286 350 350 143 180 295 352 352 143 175 265 350 350 180 180 195 255 255 180 195 255 295 295 Weight (kg) with drum type 145 185 295 365 365 145 180 265 355 355 ØR C C1 C2 C N L X1 X2 100 100 125 160 160 100 125 160 200 200 140 140 160 275 275 140 160 275 325 325 115 130 45 -55 -55 115 110 -70 -105 -105 340 385 545 580 740 340 365 430 530 690 260 360 740 1510 1565 270 415 985 1880 1935 270 370 770 1550 1605 280 425 1005 1930 1985 280 395 870 1700 1755 290 450 1115 2120 2175 360 460 1060 2120 2175 370 530 1346 2540 2595 390 490 1160 2350 2405 400 560 1446 2764 2819 © DRH4 hoist with cylindrical motor. N° of rope falls 2/1 4/1 DRH 1 630 480 b = 180 (mm) DRH 2 DRH 3 640 500 680 610 Hook clearance E (mm) in relation to the width of beam b (mm) and size of the DRH wire rope hoist b = 220 (mm) b = 300 (mm) DRH 4 DRH 1 DRH 2 DRH 3 DRH 4 DRH 1 DRH 2 DRH 3 DRH 4 DRH 1 830 790 670 530 680 550 680 610 830 790 770 620 780 650 780 650 880 790 890 740 b = 400 (mm) DRH 2 DRH 3 900 770 900 770 DRH 4 1000 850 N.B.: For the speed, power and position of the wheel see page 18 Trolley DST1R DST2R DST3R DST4R Beam specifications table for DST trolleys Min. beam width Max. thickness (mm) (mm) 90 119 135 180 20 23 35 41 23 DRT DOUBLE GIRDER TROLLEYS FOR DRH STANDING ELECTRIC ROPE HOISTS 2 FALL (2/1) AND 4 FALL (4/1) VERSIONS Reactions on the supports, see page 32 DRH series electric wire rope hoists with 2 and 4 rope falls with DRT double girder trolley, in standing configuration For dimensions I1 - S1 - S2 - S3 - N - P - H see page 19 H6 = H - H5 (*) The standard gauge is S=1000 mm, a gauge of S = 1200 mm can be supplied upon request N° of rope falls 2/1 4/1 DHR type DRT trolley Gauge trolley S (mm) 1 1 1000 2 1 1000 3 2 1000 4 3 1000 ©4 3 1000 Type of drum DRH Weight DRH + DRT (kg) G1 G2 G3 G4 G5 Overall dimensions (mm) G6 T1 T2 ØR H4 H5 C N L X1 X2 C N L X1 X2 C N L X1 X2 C N L X1 X2 C N L X1 X2 236 250 280 306 336 296 306 350 376 406 716 750 860 946 1000 1252 1298 1492 1675 1865 1307 1353 1547 1730 1920 710 830 1230 1500 1770 710 830 1230 1500 1770 890 1030 1550 1840 2230 1060 1200 1760 2210 2710 1060 1200 1760 2210 2710 940 1060 1460 1730 2000 940 1060 1460 1730 2000 1202 1342 1862 2152 2542 1446 1586 2146 2596 3096 1446 1586 2146 2596 3096 155 157,5 170 150 120 115 115 115 120 120 145 145 145 145 145 170 170 170 180 180 170 170 170 180 180 155 157,5 170 150 120 115 115 115 120 120 145 145 145 145 145 170 170 170 180 180 170 170 170 180 180 66 66 66 66 66 66 66 66 66 66 80 80 80 80 80 90 90 90 90 90 90 90 90 90 90 392 392 392 392 392 392 392 392 392 392 461 461 461 461 461 520 520 520 520 520 520 520 520 520 520 210 207,5 195 215 245 295 295 295 290 290 404 404 404 404 404 492 492 492 482 482 652 652 652 642 642 -15 -17,5 -30 -10 20 40 40 40 35 35 -96 -96 -96 -96 -96 -143 -143 -143 -153 -153 -143 -143 -143 -153 -153 125 125 125 125 125 125 125 125 125 125 160 160 160 160 160 200 200 200 200 200 200 200 200 200 200 145 145 145 145 145 145 145 145 145 145 190 190 190 190 190 228 228 228 228 228 228 228 228 228 228 391 391 391 391 39 433 433 433 433 433 598 598 598 598 598 698 698 698 698 698 698 698 698 698 698 C N L X1 X2 C N L X1 X2 1350 1397 1617 1822 2055 1405 1452 1672 1877 2110 520 520 520 520 520 520 520 520 520 520 492 492 492 482 482 652 652 652 642 642 -143 -143 -143 -153 -153 -143 -143 -143 -153 -153 200 200 200 200 200 200 200 200 200 200 235 235 235 235 235 235 235 235 235 235 727 727 727 727 727 727 727 727 727 727 Trolleys DRT3 with hoists DRH4 (25 t) 4 3 1000 ©4 3 1000 4/1 ©DRH4 hoist with cylindrical motor. N.B.: For the speed, power and dimensions of the wheels see page 18 24 1060 1200 1760 2210 2710 1060 1200 1760 2210 2710 1446 1586 2146 2596 3096 1446 1586 2146 2596 3096 170 170 170 180 180 170 170 170 180 180 170 170 170 180 180 170 170 170 180 180 90 90 90 90 90 90 90 90 90 90 DRT DOUBLE GIRDER TROLLEYS FOR DRH SUSPENDED ELECTRIC ROPE HOISTS - 2 FALL (2/1) AND 4 FALL (4/1) VERSIONS Reactions on the supports, see page 32 DRH series electric wire rope hoists with 2 and 4 rope falls with DRT double girder trolley, in suspended configuration For dimensions I1 - S1 - S2 - S3 - N - P - H see page 19 H8 = H + H7 (*) The standard gauge is S = 1000 mm, a gauge of S = 1200 mm can be supplied upon request N° of rope falls 2/1 4/1 DHR type DRT trolley Gauge trolley S (mm) 1 1 1000 2 1 1000 3 2 1000 4 3 1000 ©4 3 1000 Type of drum DRH Weight DRH + DRT (kg) G1 G2 G3 G4 G5 Overall dimensions (mm) G6 T1 T2 ØR H4 H7 C N L X1 X2 C N L X1 X2 C N L X1 X2 C N L X1 X2 C N L X1 X2 236 250 280 306 336 296 306 350 376 406 716 750 860 946 1000 1240 1286 1480 1656 1846 1295 1341 1535 1711 1901 710 830 1230 1500 1770 710 830 1230 1500 1770 890 1030 1550 1840 2230 1060 1200 1760 2210 2710 1060 1200 1760 2210 2710 940 1060 1460 1730 2000 940 1060 1460 1730 2000 1202 1342 1862 2152 2542 1446 1586 2146 2596 3096 1446 1586 2146 2596 3096 155 157,5 170 150 120 115 115 115 120 120 145 145 145 145 145 170 170 170 180 180 170 170 170 180 180 155 157,5 170 150 120 115 115 115 120 120 145 145 145 145 145 170 170 170 180 180 170 170 170 180 180 66 66 66 66 66 66 66 66 66 66 80 80 80 80 80 90 90 90 90 90 90 90 90 90 90 392 392 392 392 392 392 392 392 392 392 461 461 461 461 461 520 520 520 520 520 520 520 520 520 520 210 207,5 195 215 245 295 295 295 290 290 404 404 404 404 404 492 492 492 482 482 652 652 652 642 642 -15 -17,5 -30 -10 20 40 40 40 35 35 -96 -96 -96 -96 -96 -143 -143 -143 -153 -153 -143 -143 -143 -153 -153 125 125 125 125 125 125 125 125 125 125 160 160 160 160 160 200 200 200 200 200 200 200 200 200 200 145 145 145 145 145 145 145 145 145 145 190 190 190 190 190 228 228 228 228 228 228 228 228 228 228 13 13 13 13 13 15 15 15 15 15 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 ©DRH4 hoist with cylindrical motor. N.B.: For the speed, power and dimensions of the wheels see page 18 25 DRT DOUBLE GIRDER TROLLEYS FOR DRH ELECTRIC ROPE HOISTS TRANSVERSAL VERSION WITH 2 FALL (2/1) AND 4 FALL (4/1) VERSIONS Reactions on the supports, see page 33 DRH series electric wire rope hoists with 2 and 4 rope falls with DRT double girder trolley, in transversal standing configuration For dimensions I1 - S1 - S2 - S3 - N - P – H2 see page 19 H = H5 + H6 N° of rope falls 2/1 4/1 ©DRH4 DHR type DRT trolley Gauge trolley S (mm) 1 1 1000 2 1 1000 1200 3 2 4 3 ©4 3 1000 1400 1000 1200 1000 1200 Weight DRH + DRT (kg) G1 G2 G3 G4 G5 G6 G7 T1 T2 ØR H4 H5 C N L C N L C N L C N C N 216 226 270 276 286 346 660 686 830 1190 1240 1245 1295 400 400 710 400 400 710 500 500 890 600 600 600 600 630 630 940 630 630 940 812 812 1202 986 986 986 986 315 315 470 315 315 470 406 406 601 493 493 493 493 315 300 110 267 252 200 195 170 140 140 200 140 200 66 66 66 66 66 66 80 80 80 90 90 90 90 392 392 392 392 392 392 461 461 461 520 520 520 520 285 185 0 253 148 0 205 90 0 140 140 140 140 99 114 304 192 207 259 430 455 485 625 565 785 725 422 322 137 375 270 122 461 346 256 440 440 440 440 125 125 125 125 125 125 160 160 160 200 200 200 200 145 145 145 145 145 145 190 190 190 228 228 228 228 375 375 375 415 415 415 570 570 570 698 698 698 698 hoist with cylindrical motor. N.B.: For the speed, power and dimensions of the wheels see page 18 26 Overall dimensions (mm) Type of drum DRH H6 2 tiri 4 tiri 405 405 315 485 485 405 630 630 520 768 768 768 768 360 360 275 425 425 335 570 570 450 722 722 722 722 DRT DOUBLE GIRDER TROLLEYS FOR DRH ELECTRIC ROPE HOISTS 6 FALL (6/1) VERSION Reactions on the supports, see page 33 For dimensions I1 - N - H2 – H4 – L2 see page 20 N° of rope falls DHR type 3 4 DRT trolley *3 ** 3 6/1 ©4 ** 3 Gauge trolley S (mm) 1200 1400 1200 1400 1200 1400 1200 1400 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 Type of drum DRH N L X1 X2 N L X1 X2 N L X1 X2 Weight DRH + DRT (kg) G1 G2 G3 G4 G5 Overall dimensions (mm) G6 S3 S4 T1 H1 H3 ØR 1120 1140 1290 1310 1380 1400 1510 1530 1800 2100 2400 2000 2300 2700 2250 2500 2800 2390 2650 2950 1855 2155 2455 2055 2355 2755 2305 2555 2855 2445 2705 3005 1500 1500 2070 2070 2500 2500 3000 3000 1500 1500 1500 2070 2070 2070 2500 2500 2500 3000 3000 3000 1500 1500 1500 2070 2070 2070 2500 2500 2500 3000 3000 3000 1900 1900 2470 2470 2900 2900 3400 3400 1900 1900 1900 2470 2470 2470 2900 2900 2900 3400 3400 3400 1900 1900 1900 2470 2470 2470 2900 2900 2900 3400 3400 3400 185 185 185 185 185 185 185 185 230 650 930 230 650 930 230 650 930 230 650 930 230 650 930 230 650 930 230 650 930 230 650 930 360 360 400 400 540 540 410 410 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 520 520 520 520 520 520 520 520 - 565 565 575 575 575 575 575 575 580 580 580 590 590 590 590 590 590 590 590 590 580 580 580 590 590 590 590 590 590 590 590 590 415 515 415 515 415 515 415 515 470 470 470 470 470 470 470 470 470 470 470 470 470 470 470 470 470 470 470 470 470 470 470 470 105 105 95 95 95 95 95 95 255 255 255 245 245 245 245 245 245 245 245 245 415 415 415 405 405 405 405 405 405 405 405 405 820 820 820 820 820 820 820 820 960 960 960 960 960 960 960 960 960 960 960 960 960 960 960 960 960 960 960 960 960 960 960 960 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 235 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 ©DRH4 hoist with cylindrical motor. N.B.: For the speed, power and dimensions of the wheels see page 18 * The trolley is made with a single gear motor (motor 100) ** The trolley is made with double gear motor (motor 80) 27 DRT DOUBLE GIRDER TROLLEYS FOR DRH ELECTRIC ROPE HOISTS 8 FALL (8/1) VERSION Reactions on the supports, see page 33 or dimensions I1 - N - H2 – H4 – L2 see page 20 N° of rope falls DHR type DRT trolley Gauge trolley S (mm) 3 *3 ** 3 ** 3 *3 ** 3 ** 3 *3 ** 3 ** 3 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 1400 2240 2800 4 *** 4 8/1 ©4 *** 4 Type of drum DRH L X1 X2 N L X1 X2 N L X1 X2 Weight DRH + DRT (kg) Overall dimensions (mm) G1 G2 G3 G4 G5 G6 S3 S4 T1 H1 H3 ØR 1400 1480 1730 1480 1560 1820 1580 1750 1950 2000 2400 2600 2300 2600 2800 2500 2900 3100 2680 3030 3270 2055 2455 2655 2355 2655 2855 2555 2955 3155 2735 3085 3325 2070 2070 2070 2500 2500 2500 3000 3000 3000 1500 1500 1500 2060 2060 2060 2500 2500 2500 3000 3000 3000 1500 1500 1500 2060 2060 2060 2500 2500 2500 3000 3000 3000 2470 2470 2470 2900 2900 2900 3400 3400 3400 1950 1950 1950 2510 2510 2510 2950 2950 2950 3450 3450 3450 1950 1950 1950 2510 2510 2510 2950 2950 2950 3450 3450 3450 185 605 885 185 605 885 185 605 885 230 550 830 230 550 830 230 550 830 230 550 830 230 550 830 230 550 830 230 550 830 230 550 830 400 400 400 540 540 540 650 650 650 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 90 90 90 90 90 90 90 90 90 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 520 520 520 - 635 635 635 635 635 635 635 635 635 678 678 678 678 678 678 688 688 688 688 688 688 678 678 678 678 678 678 688 688 688 688 688 688 515 515 515 515 515 515 515 515 515 470 570 570 470 570 570 470 570 570 470 570 570 470 570 570 470 570 570 470 570 570 470 570 570 95 95 95 95 95 95 95 95 95 230 230 230 230 230 230 220 220 220 220 220 220 390 390 390 390 390 390 380 380 380 380 380 380 820 820 820 820 820 820 820 820 820 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 235 235 235 235 235 235 235 235 235 287 287 287 287 287 287 287 287 287 287 287 287 287 287 287 287 287 287 287 287 287 287 287 287 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 ©DRH4 hoist with cylindrical motor. N.B.: For the speed, power and dimensions of the wheels see page 18 * The trolley is made with a single gear motor (motor 100) ** The trolley is made with double gear motor (motor 80) 28 *** The trolley is made with double gear motor (motor 100). REACTIONS ON THE SUPPORTS DRH SERIES ELECTRIC WIRE ROPE HOISTS WITH 2 AND 4 ROPE FALLS IN STANDING OR SUSPENDED EXECUTION Hoist DRH type 1 2 3 4 Capacity (kg) R1 800 1000 1250 1600 2000 1250 1600 2000 2500 3200 2500 3200 4000 5000 6300 4000 5000 6300 8000 10000 349 425 521 654 806 555 693 852 1050 1327 1133 1407 1721 2112 2621 1813 2195 2691 3341 4104 Drum C R2 R1 117 141 170 212 260 160 197 238 290 363 347 423 509 618 759 614 732 886 1086 1323 373 455 557 699 863 586 732 898 1107 1398 1193 1482 1812 2224 2760 1901 2302 2823 3505 4308 Hoist DRH type 1 2 3 4 Capacity (kg) R1 1600 2000 2500 3200 4000 2500 3200 4000 5000 6300 5000 6300 8000 10000 12500 8000 10000 12500 16000 20000 25000 546 671 826 1046 1296 847 1065 1315 1627 2034 1672 2062 2572 3172 3922 2654 3237 3966 4987 6154 7645 Drum C R2 R1 324 399 494 624 774 500 632 782 970 1213 1086 1346 1686 2086 2586 1826 2243 2764 3493 4326 5363 617 759 935 1184 1468 943 1188 1468 1818 2273 1870 2308 2882 3558 4403 2938 3589 4403 5543 6845 8502 Two rope fall (2/1) version Static hoist reactions: R1; R2 = daN Drum N Drum L R2 R1 R2 97 115 138 171 207 136 165 199 240 299 302 363 433 521 635 543 642 771 939 1136 410 500 611 768 946 634 792 972 1197 1512 1309 1623 1982 2430 3013 2097 2536 3109 3857 4738 69 79 93 111 133 99 116 136 161 196 223 259 300 352 419 407 468 545 647 766 Four rope fall (4/1) version Static hoist reactions: R1; R2 = daN Drum N Drum L R2 R1 R2 258 316 389 491 607 409 514 634 784 979 900 1112 1388 1712 2117 1561 1910 2346 2956 3654 4521 708 871 1074 1360 1686 1078 1358 1678 2078 2598 2172 2683 3351 4137 5118 3535 4324 5310 6690 8268 10261 176 213 260 324 398 289 359 439 539 669 640 779 961 1175 1444 1035 1246 1510 1880 2302 2837 R1 Drum X1 428 520 636 797 981 662 823 1007 1237 1560 1342 1662 2029 2487 3082 2216 2670 3261 4032 4941 R1 757 929 1145 1447 1792 1145 1439 1776 2197 2743 2281 2818 3520 4346 5378 3801 4639 5686 7153 8828 10944 Drum X1 R2 R1 62 70 80 93 109 93 107 123 143 170 203 233 266 308 363 384 430 489 568 660 442 536 653 817 1004 677 841 1028 1262 1589 1373 1699 2073 2539 3146 2272 2736 3339 4127 5055 R2 R1 143 171 205 253 308 245 301 364 444 547 544 657 805 979 1197 874 1036 1239 1522 1847 2259 787 965 1189 1501 1858 1187 1491 1839 2273 2838 2385 2945 3677 4537 5613 3956 4828 5919 7445 9190 11391 Drum X2 R2 58 64 72 83 95 88 99 112 128 151 187 211 237 271 314 353 389 436 498 570 Drum X2 R2 123 145 171 209 252 213 259 311 377 462 465 555 673 813 987 744 872 1031 1255 1510 1837 DRH SERIES ELECTRIC ROPE HOISTS WITH 6 AND 8 ROPE FALLS IN STANDING EXECUTION Hoist DRH Capacity type (kg) 3 4 16000 20000 25000 32000 Hoist DRH Capacity type (kg) 3 4 20000 25000 40000 50000 Six rope fall (6/1) version Static hoist reactions: R1; R2 = daN Drum N Drum L Drum X1 Drum X2 R1 R2 R1 R2 R1 R2 R1 R2 6415 7968 10246 13015 1883 2329 2788 3519 7179 8917 11321 14378 1161 1423 1784 2227 7385 9172 11758 14918 970 1183 1451 1791 7573 9403 12033 15266 807 977 1202 1469 Eight rope fall (8/1) versio Static hoist reactions: R1; R2 = daN Drum N Drum L Drum X1 Drum X2 R1 R2 R1 R2 R1 R2 R1 R2 13920 17307 6635 8247 8400 10501 16506 20529 1950 2349 4118 5096 8750 10929 17484 21734 1615 1936 3245 3996 9050 11310 18139 22548 1340 1580 2616 3207 29 DST/N/S MONORAIL TROLLEYS FOR DRH ELECTRIC WIRE ROPE HOISTS – 2 (2/1) FALL VERSION Hoist DRH tYPE 1 2 3 4 Capacity (kg) R1 800 1000 1250 1600 2000 1250 1600 2000 2500 3200 2500 3200 4000 5000 6300 4000 5000 6300 8000 10000 377 453 549 682 834 581 720 878 1076 1353 1171 1445 1759 2150 2660 1901 2283 2780 3429 4193 Drum C R2 R1 131 155 184 226 274 174 210 252 304 377 367 443 529 638 778 659 777 930 1131 1367 400 481 583 726 889 611 757 923 1132 1423 1230 1519 1849 2261 2797 1990 2391 2913 3595 4397 Drum N R2 110 129 152 184 221 149 178 212 253 312 320 381 451 539 653 588 687 815 983 1181 Static hoist reactions: R1; R2 = daN Drum L R1 R2 437 527 638 795 973 661 819 999 1224 1539 1346 1660 2019 2467 3050 2184 2624 3196 3944 4825 83 93 107 125 147 112 129 149 174 209 242 278 319 371 438 451 511 589 691 810 R1 Drum X1 445 535 646 804 988 668 826 1006 1232 1554 1367 1680 2040 2490 3073 2242 2680 3250 4002 4910 R2 R1 90 100 114 131 147 120 136 156 180 209 258 295 335 385 452 498 560 640 738 830 450 541 658 822 1010 673 834 1020 1255 1581 1387 1700 2072 2538 3145 2268 2731 3334 4123 5050 Drum X2 R2 95 104 112 123 135 125 139 153 168 192 275 312 341 375 418 557 594 641 702 775 DST/N/S MONORAIL TROLLEYS FOR DRH ELECTRIC WIRE ROPE HOISTS – 4 (4/1) FALL VERSION Hoist DRH tYPE 1 2 3 4 30 Capacity (kg) R1 1600 2000 2500 3200 4000 2500 3200 4000 5000 6300 5000 6300 8000 10000 12500 8000 10000 12500 16000 20000 573 698 855 1073 1323 881 1100 1350 1663 2069 1758 2148 2658 3258 4008 2805 3389 4118 5139 6305 Drum C R2 R1 337 412 505 637 787 519 650 800 987 1231 1130 1390 1730 2130 2630 1903 2319 2840 3569 4403 644 785 963 1211 1494 978 1223 1503 1853 2308 1959 2398 2973 3648 4493 3090 3741 4555 5695 6997 Drum N R2 271 330 402 504 621 427 532 652 802 997 946 1157 1432 1757 2162 1638 1987 2423 3033 3731 Static hoist reactions: R1; R2 = daN Drum L R1 R2 735 898 1102 1387 1713 1112 1392 1712 2112 2632 2258 2768 3436 4222 5204 3685 4474 5460 6840 8417 190 227 273 338 412 306 376 456 556 686 682 822 1004 1218 1486 1110 1321 1585 1955 2378 R1 760 933 1148 1450 1795 1146 1441 1777 2198 2745 2313 2850 3552 4377 5410 3801 4639 5686 7152 8828 Drum X1 R2 R1 180 207 242 290 345 294 349 413 492 595 685 798 946 1121 1338 1099 1261 1464 1748 2072 788 967 1190 1502 1860 1186 1490 1838 2273 2838 2420 2980 3710 4572 5648 3982 4855 5945 7471 9216 Drum X2 R2 162 183 210 248 290 264 310 362 427 512 615 705 825 963 1137 1003 1130 1290 1514 1769 DST/R MONORAIL TROLLEYS FOR DRH ELECTRIC WIRE ROPE HOISTS – 2 (2/1) FALL VERSION Hoist DRH tYPE 1 2 3 4 Capacity (kg) R1 800 1000 1250 1600 2000 1250 1600 2000 2500 3200 2500 3200 4000 5000 6300 4000 5000 6300 8000 10000 392 468 563 697 849 615 753 912 1110 1387 1226 1500 1813 2205 2714 2031 2413 2910 3559 4323 Drum C R2 R1 138 162 192 233 281 190 227 268 320 393 394 470 557 665 806 724 842 995 1196 1432 416 498 600 742 906 644 790 957 1165 1457 1287 1576 1905 2317 2853 2121 2522 3044 3726 4528 Drum N R2 119 137 160 193 229 166 195 228 270 328 348 409 480 568 682 654 753 881 1049 1247 Static hoist reactions: R1; R2 = daN Drum L R1 R2 451 540 652 808 987 695 852 1032 1257 1572 1411 1725 2084 2532 3115 2327 2767 3340 4088 4968 89 100 113 132 153 128 146 166 191 226 274 310 351 403 470 523 583 660 762 882 R1 Drum X1 475 565 675 830 1010 710 870 1050 1275 1588 1470 1780 2140 2590 3170 2450 2890 3460 4210 5090 R2 R1 105 115 130 150 170 145 160 180 205 242 310 350 390 440 510 610 670 750 850 970 482 572 684 847 1035 716 877 1057 1290 1617 1495 1805 2165 2622 3228 2510 2950 3510 4298 5225 Drum X2 R2 113 123 136 148 160 154 168 188 205 228 335 375 415 458 502 665 725 815 877 950 DST/R MONORAIL TROLLEYS FOR DRH ELECTRIC WIRE ROPE HOISTS – 4 (4/1) FALL VERSION Hoist DRH tYPE 1 2 3 4 Capacity (kg) R1 1600 2000 2500 3200 4000 2500 3200 4000 5000 6300 5000 6300 8000 10000 12500 8000 10000 12500 16000 20000 590 715 871 1090 1340 920 1139 1389 1701 2107 1829 2219 2729 3329 4079 2960 3543 4273 5293 6460 Drum C R2 R1 345 420 514 645 795 538 669 819 1007 1251 1164 1424 1764 2164 2664 1980 2397 2917 3647 4480 660 802 979 1227 1511 1017 1262 1542 1892 2347 2024 2464 3038 3714 4558 3248 3899 4713 5853 7155 Drum N R2 280 338 411 513 629 446 551 671 821 1016 979 1189 1465 1789 2195 1717 2066 2502 3112 3810 Static hoist reactions: R1; R2 = daN Drum L R1 R2 748 911 1115 1400 1726 1150 1430 1750 2150 2670 2336 2847 3515 4300 5283 3862 4650 5636 7017 8594 197 234 280 345 419 325 395 475 575 705 722 861 1043 1258 1525 1198 1410 1674 2043 2466 R1 782 955 1170 1472 1818 1184 1478 1815 2235 2782 2400 2938 3640 4465 5497 3986 4824 5871 7338 9013 Drum X1 R2 R1 203 230 265 313 367 331 387 450 530 633 773 885 1033 1208 1425 1284 1446 1649 1932 2257 813 992 1215 1527 1884 1226 1530 1878 2313 2878 2513 3072 3804 4665 5741 4180 5052 6143 7670 9414 Drum X2 R2 187 208 235 273 316 304 350 402 467 552 710 800 919 1058 1232 1203 1330 1490 1713 1968 31 DRT DOUBLE GIRDER TROLLEYS FOR DRH STANDING/SUSPENDED ELECTRIC ROPE HOISTS 2 FALL (2/1) AND 4 FALL (4/1) VERSIONS Hoist DRH tYPE 1 2 3 4 Capacity (kg) R1 800 1000 1250 1600 2000 1250 1600 2000 2500 3200 2500 3200 4000 5000 6300 4000 5000 6300 8000 10000 335 400 481 594 724 529 651 791 955 1209 1084 1326 1602 1948 2397 1737 2077 2518 3096 3775 Drum C R2 R1 179 214 258 320 390 236 289 349 425 531 496 604 728 882 1083 831 991 1200 1472 1793 369 428 515 637 776 562 691 839 1025 1284 1146 1403 1696 2063 2539 1825 2184 2649 3259 3975 Hoist DRH tYPE Capacity (kg) 1600 2000 1 2500 3200 4000 2500 3200 2 4000 5000 6300 5000 6300 3 8000 10000 12500 8000 10000 12500 4 16000 20000 *25000 *Version only supported 32 R1 535 649 792 992 1220 830 1034 1268 1560 1940 1668 2026 2508 3076 3785 2640 3196 3892 4866 5979 7426 Drum C R2 R1 383 469 576 726 898 568 714 880 1088 1368 1200 1482 1850 2282 2823 1980 2424 2978 3754 4641 5777 587 713 870 1090 1342 908 1133 1391 1713 2133 1815 2223 2755 3381 4164 2862 3470 4230 5295 6512 8088 Two rope fall (2/1) version Static hoist reactions: R1; R2 = daN Drum N Drum L R2 R1 R2 162 193 231 284 345 211 257 309 373 464 449 542 649 782 956 763 904 1089 1329 1613 404 482 580 718 875 626 770 935 1142 1430 1295 1583 1912 2323 2858 2064 2467 2991 3677 4484 131 153 180 217 260 164 196 230 273 335 365 417 488 577 692 611 708 834 998 1191 Four rope fall (4/1) version Static hoist reactions: R1; R2 = daN Drum N Drum L R2 R1 R2 338 412 505 635 783 495 620 762 940 1170 1060 1302 1620 1994 2461 1781 2173 2663 3348 4131 5138 675 821 1003 1258 1549 1047 1307 1605 1977 2460 2117 2593 3216 3948 4863 3425 4158 5074 6357 7823 9720 265 319 387 482 591 378 468 570 698 866 813 987 1214 1482 1817 1315 1582 1916 2383 2917 3616 R1 Drum X1 430 514 618 765 932 662 801 972 1185 1484 1368 1666 2006 2432 2984 2218 2639 3186 3902 4743 R1 734 892 1090 1366 1682 1109 1384 1699 2092 2603 2251 2755 3413 4187 5155 3683 4466 5444 6814 8380 10410 Drum X1 R2 R1 113 129 150 178 211 151 177 206 243 294 340 392 452 526 624 585 664 767 901 1606 457 545 654 808 984 676 829 1004 1223 1530 1419 1726 2077 2515 3085 2340 2776 3342 4082 4953 R2 R1 219 261 313 387 471 329 404 489 596 735 722 868 1060 1286 1568 1145 1362 1634 2014 2448 3028 783 960 1161 1454 1790 1159 1446 1774 2183 2716 2368 2897 3589 4403 5420 3907 4730 5758 7198 8844 10990 Drum X2 R2 101 113 129 150 174 142 164 189 220 263 316 369 408 470 550 558 622 706 816 945 Drum X2 R2 186 218 257 314 378 294 357 429 520 637 632 753 911 1097 1330 1016 1193 1415 1725 2079 2565 DRT DOUBLE GIRDER TROLLEYS FOR DRH ELECTRIC WIRE ROPE HOISTS – TRANSVERSAL 2 FALL (2/1) AND 4 FALL (4/1) VERSIONS Hoist DRH Capacity tYPE (kg) 1 2 3 4 DRH tYPE 1 2 3 4 800 1000 1250 1600 2000 1250 1600 2000 2500 3200 2500 3200 4000 5000 6300 4000 5000 6300 8000 10000 Hoist Capacity (kg) 1600 2000 2500 3200 4000 2500 3200 4000 5000 6300 5000 6300 8000 10000 12500 8000 10000 12500 16000 20000 Two rope fall (2/1) version Static hoist reactions: R1; R2 = daN Drum C Drum N Drum L R1 R2 R1 R2 R1 R2 305 364 438 541 659 482 593 720 878 1100 1046 1282 1552 1890 2328 1802 2162 2630 3242 3962 199 240 291 363 445 273 337 410 502 630 507 621 751 913 1125 741 881 1063 1301 1581 313 374 450 555 676 494 607 737 899 1125 1084 1329 1609 1959 2414 1810 2168 2634 3243 3960 194 233 282 352 431 264 326 396 484 608 479 584 704 854 1049 755 897 1081 1322 1605 405 484 584 723 882 577 709 859 1046 1309 1266 1548 1871 2275 2800 – – – – – 125 146 171 207 148 211 254 304 367 454 369 437 514 610 735 – – – – – Four rope fall (4/1) version Static hoist reactions: R1; R2 = daN Drum C Drum N Drum L R1 R2 R1 R2 R1 R2 500 607 741 928 1142 783 977 1198 1475 1834 1633 2000 2480 3045 3752 2757 3347 4085 5117 6297 408 501 617 780 966 605 761 940 1163 1454 1197 1480 1850 2285 2828 1838 2248 2760 3478 4298 515 625 763 955 1175 805 1004 1231 1515 1885 1704 2087 2589 3179 3916 2847 3455 4215 5280 6497 398 488 600 758 938 588 739 912 1128 1408 1139 1406 1754 2164 2677 1773 2165 2655 3340 4123 670 815 996 1250 1540 949 1182 1449 1782 2215 2045 2504 3105 3812 4696 – – – – – DRT DOUBLE GIRDER TROLLEYS FOR DRH ELECTRIC WIRE ROPE TROLLEYS 6 FALL (6/1) AND 8 FALL (8/1) VERSIONS Gauge trolley S (mm) 1200 1400 2240 2800 Gauge trolley S (mm) 1400 2240 2800 Capacity (kg) 16000 20000 16000 20000 25000 32000 25000 32000 25000 32000 Capacity (kg) 25000 40000 50000 25000 40000 50000 25000 40000 50000 Six rope fall (6/1) version Static hoist reactions: R1; R2 = daN Drum N Drum L Drum X1 Drum X2 R1 R2 R1 R2 R1 R2 R1 R2 5360 6610 5367 6615 8250 10400 8350 10500 8450 10600 3200 3950 3203 3955 5150 6500 5200 6550 5250 6600 6210 7655 6214 7660 9600 12100 9700 12200 9800 12300 2435 2990 2441 3000 3900 4900 3950 4950 4050 5050 6620 8160 6627 8170 10250 12980 10350 13050 10400 13100 2070 2530 2073 2530 3375 4150 3400 4200 3500 4300 6970 8587 6997 8600 10838 13650 10925 13737 11025 13837 1785 2168 1788 2170 2857 3545 2900 3588 2950 3638 Eight rope fall (8/1) versio Static hoist reactions: R1; R2 = daN Drum N Drum L Drum X1 Drum X2 R1 R2 R1 R2 R1 R2 R1 R2 11500 14400 11600 14340 11650 14400 9500 11600 9600 11860 9650 11900 9085 13850 17550 9159 13950 17280 9242 14000 17340 4115 7300 8600 4081 7350 9020 4123 7400 9060 9780 14900 18950 9845 15050 18590 9932 15100 18660 3460 6350 7300 3435 6400 7860 3478 6450 7890 10380 16325 20150 10437 16442 20295 10504 16522 20375 2910 5043 6200 1938 5101 6248 2971 5141 6288 265 320 389 485 595 474 591 724 891 1108 870 1061 1310 1603 1969 – – – – – 33 TABLE Φ DRUM AND SHEAVE PITCH DIAMETER DHR type Ф Rope (mm) Ф Drum pitch diameter (mm) Ф Sheave pitch diameter (mm) 1 7 8 9 12 13 15 16 159 193 194 242 243 323 324 157 180 181 269 270 337 338 2 3 4 TABLE OF HOOKS FOR DRH DRH size N° Falls 2/1 1 4/1 2/1 2 4/1 2/1 3 4/1 6/1 8/1 2/1 4 4/1 6/1 8/1 34 FEM 1Bm Capacity Type N° 3200 5000 10000 16000 25000 50000 - - 1.6V - 2.5T - 5T - 10P 10T 12T - Type of hook in relation to the capacity (kg) and FEM service group FEM 1Am FEM 2m FEM 3m Capacity Type N° Capacity Type N° Capacity Type N° 1250 1600 2000 1600 2000 2500 3200 4000 1600 2000 2500 3200 3200 4000 5000 6300 2500 3200 4000 5000 6300 5000 6300 8000 10000 12500 20000 25000 5000 6300 8000 10000 10000 12500 16000 20000 25000 32000 40000 - 08V 1.6V 1.6V 2.5T 2.5T 5T 10S 10S 5T 10P 10T 12T 12T - 1000 1250 1600 1250 1600 2000 2500 3200 1250 1600 2000 2500 2500 3200 4000 5000 2000 2500 3200 4000 5000 4000 5000 6300 8000 10000 16000 20000 4000 5000 6300 8000 8000 10000 12500 16000 20000 25000 32000 – 40000 08V 1.6V 1.6V 2.5T 2.5T 5T 10S 10S 5T 10P 10T 12T 12V 800 1000 1250 1000 1250 1600 2000 2500 1000 1250 1600 2000 2000 2500 3200 4000 1600 2000 2500 3200 4000 3200 4000 5000 6300 8000 – – 3200 4000 5000 6300 6300 8000 10000 12500 – – – Hook Dimensions Dimensions (mm) a1 h2 08V 33 37 1.6V 38 48 1.6V 38 48 2.5T 43 58 2.5T 43 58 5T 50 75 – – 77 106 5T 50 75 77 106 87 118 10P – – – SPECIFICATIONS OF MOTORS, FUSES AND POWER CABLES DRH Hoist Minimum power cable section 400V - ( ΔU20V ) φ mm2 L =m Motor type Poles Installed power ( kW ) COS v Ia - ( A ) 400V - 50Hz In - ( A ) 400V - 50Hz Line fuse ( A ) 400V - 50Hz 112K4R 4 3 0.75 40 8 16 2.5 ≤ 30 112K5R 4/12 3/1 0.72/0.5 38/13 8/6.6 16 2.5 ≤ 30 132K4R 4 5 0.75 58 12 20 4 ≤ 30 132K5R 4/12 5/1.65 0.78/0.5 50/17 12/10 20 4 ≤ 30 160K4R 4 10 0.8 110 22 32 6 ≤ 30 160K5R 4/12 10/3.3 0.77/0.46 100/20 24/18 32 6 ≤ 30 180K4R 4 16 0.82 175 34 63 10 ≤ 20 180K5R 4/12 16/5.3 0.78/0.46 170/55 38/25 63 10 ≤ 20 180C4R 4 24 0.88 330 48 80 16 ≤ 20 180C5R 4/12 24/7.8 0.88/0.5 330/80 48/32 80 16 ≤ 20 1 2 3 4 4 Cilindrico Trolley DST / DRT Motor type Poles Installed power ( kW ) COS v Ia - ( A ) 400V - 50Hz In - ( A ) 400V - 50Hz 4.4/1.2 6 4 5.2 5.5/1.6 5.6 3.3 9.7 6.8/1.9 7.7 3.9 9.7 16/3.6 16 8.5 23 1.2/0.9 1.0 1.0 1.3 1.3/1.1 1.3 0.9 1.9 1.6/1.3 1.7 1.1 1.9 3.1/1.8 2.9 1.7 4.3 71K3P 2/8 0.4/0.09 0.75/0.6 71C2P 2 0.32 0.72 71C4P 4 0.16 0.5 71K2PI 2 Inverter 0.5 0.72 80K3P 2/8 0.5/0.12 0.85/0.6 80K2P 2 0.50 0.8 DST3 DRT2 80K4P 4 0.25 0.65 80K2PI 2 Inverter 0.8 0.8 80K3PL 2/8 0.63/0.15 0.82/0.57 80K2PL 2 0.63 0.75 DST4 * DRT3 80K4PL 4 0.32 0.65 80K2PI 2 Inverter 0.8 0.8 100K3P 2/8 1.25/0.31 0.84/0.6 100K2P 2 1.25 0.83 ** DRT3 *** DRT4 100K4P 4 0.63 0.8 100K2PI 2 Inverter 2.0 0.86 - The DST trolleys articulated version are made with double gear motor. Thus the powers shown in the table need to be doubled. DST1 DST2 DRT1 * The DRT3 trolley for DRH4 hoists with 6 falls is made with double traverse gear motor. The DRT3 trolley for DRH3 hoists with 8 falls (frame gauge 2240-2800) is made with double traverse gear motor. Thus the powers shown in the table need to be doubled. ** The DRT3 trolley for DRH4 hoists with 4 falls, DRH3 with 6 falls (frame gauge 1200-1400) and DRH3 with 8 falls (frame gauge 1400) is made with single traverse gear motor. *** The DRT4 trolley for DRH4 hoists with 8 falls is made with double traverse gear motor. Thus the powers shown in the table need to be doubled. 35 www.donati-europe.com Factory: Via Archimede, 52 - 20864 Agrate Brianza (MB) - Italia TMAN02CG00 DONATI SOLLEVAMENTI S.r.l. Via Quasimodo, 17 - 20025 Legnano (Milano) - Italia Tel. +39 0331 14811 - Fax. +39 0331 1481880 e-mail: [email protected], [email protected]
Similar documents
Donati DRH Wire Rope Hoists Brochure
gear motor, can be connected to a cycle counter, selectors, limit switches, encoders, safety brakes etc. Furthermore, being perfectly symmetrical in the special execution with drum right and left g...
More informationElectric Wire Rope Hoist DRH Series
gear motor, can be connected to a cycle counter, selectors, limit switches, encoders, safety brakes etc. Furthermore, being perfectly symmetrical in the special execution with drum right and left g...
More informationschedule of classes - Dallas Baptist University
Dallas Baptist University Mission Statement The purpose of Dallas Baptist University is to provide Christ-centered quality higher education in the arts, sciences, and professional studies at both t...
More informationName Price Category 0-0fc9bf2f3ba84.media $36.95 CAD / year 0
0c52868fe050bd1e63d7d534b61f476c4a15ff7d.media $36.95 CAD / year 0d.media $119.95 CAD / year 0e.media $119.95 CAD / year 0e5d8ac68f40312048b0e04556380618216fe3ff.media $36.95 CAD / year 0f.media $1...
More information