Fastfloor Thermal Brochure
Transcription
Fastfloor Thermal Brochure
THERMAL The ultimate thermal flooring system THERMAL Incorporating Springvale’s Beamshield® Expanded Polystyrene (EPS) Flooring Block, our FASTFLOOR THERMAL system is the ultimate solution for reducing thermal bridging with no additional insulation required. In addition, FASTFLOOR THERMAL is quick, easy to install and adds value to your build. Suitable for ground floors. TOTAL FLOOR INSULATION FASTFLOOR THERMAL provides total floor insulation, reducing thermal bridging with no additional insulation required. INCREASED PRODUCTIVITY These lightweight blocks are quick and easy to install with no special skills required – increasing speed of build. FIRE CLASSIFICATION This system has a Euroclass B classification. THERMAL PERFORMANCE FASTFLOOR THERMAL delivers excellent U-values as low as 0.10W/mK and can significantly improve SAP ratings VERSATILE FASTFLOOR THERMAL can be installed in inclement weather and is maintenance, rot and damp free. FASTFLOOR THERMAL for ultimate thermal performance with no additional insulation required 6 1 2 1 Telescope Ventilator 2DPC 3 FASTFLOOR Beam 4Beamshield® 5 Coursing slips 6Screed 3 5 4 PRODUCT PROPERTIES CONCENTRATED LOAD (kn) THERMAL CONDUCTIVITY (W/mK) WATER VAPOUR DIFFUSION FACTOR (litres) DENSITY (kg/m3) BEAMSHIELD® PLUS WHITE 1.5 0.038 20-40 15-16 BEAMSHIELD® PLUS PLATINUM 1.5 0.030 20-40 16-17 PRODUCT U-VALUE PERFORMANCE EXAMPLES PRODUCT BEAMSHIELD® PLUS WHITE 228MM BEAMSHIELD PLUS WHITE 244MM ® BEAMSHIELD PLUS PLATINUM 244MM ® BEAMSHIELD® PLUS PLATINUM 282MM BEAMSHIELD® PLUS PLATINUM 331MM BEAMSHIELD® PLUS PLATINUM 378MM P/A RATIO U-VALUE (W/m2K) SINGLE BEAM INSULATION TYPE (K=W/mK) 0.50 0.20 NONE REQUIRED 0.60 0.21 NONE REQUIRED 0.70 0.22 NONE REQUIRED 0.50 0.19 NONE REQUIRED 0.60 0.19 NONE REQUIRED 0.70 0.20 NONE REQUIRED 0.50 0.16 NONE REQUIRED 0.60 0.17 NONE REQUIRED 0.70 0.20 NONE REQUIRED 0.50 0.14 NONE REQUIRED 0.60 0.14 NONE REQUIRED 0.70 0.14 NONE REQUIRED 0.50 0.11 NONE REQUIRED 0.60 0.12 NONE REQUIRED 0.70 0.12 NONE REQUIRED 0.50 0.10 NONE REQUIRED 0.60 0.10 NONE REQUIRED 0.70 0.10 NONE REQUIRED * U Values based on nominal 600mm and nominal 300mm centres at a ratio of 4 to 1 72mm THERMAL BRIDGING In addition to the heat loss through the floor, expressed by the U-value of the floor, considerable heat is also lost at the junction with the external wall. This is described as thermal bridging. 150mm Dealing effectively with thermal bridging can benefit the SAP energy calculations up to 12% for a typical semidetached house. Up to 2% of this can be attributed to the ground floor junction with the external wall. The use of FASTFLOOR THERMAL can help to vastly reduce this heat loss. As the thermal bridging can vary quite considerably dependent upon the construction and U-value of the floor and walls, the thermal bridging values (psi values) are calculated for each project. Further information can be provided upon request. 135mm TYPICAL FASTFLOOR THERMAL DETAIL 1 30mm perimeter strip 2 Cavity wall insulation to overlap base of beam 3 Aircrete trench block 4 Lightweight blockwork 1 FGL 2 Beamshield® units 150 5 5DPC 6 150mm MIN MIN 150 MM VOID 3 4 6 V1/2016 To find out more about FASTFLOOR and the best solution for your project call 0333 003 4701 or email [email protected] TARMAC.COM ©2016 Tarmac Building Products Limited. In association with Beamshield®