Cerberus PRO – C-NET devices
Transcription
Cerberus PRO – C-NET devices
Aspirating smoke detection FDnet/C-NET FDnet/C-NET Operating voltage DC 19...30 V DC 19...30 V Sound level – High 33 dB – Medium 30 dB – Low 26 dB – High 37 dB – Medium 33 dB – Low 30 dB – 3 alarm state indicators – Fault indicator – Bargraph for smoke and airflow level – 4 alarm state indicators – Purge, dust, fault indicator – Bargraph for smoke and airflow level Area coverage Up to 500 m² Alarm threshold – Prealarm and – Info alarm, prealarm and fire 1 (5 parameter sets) fire 1 (10 parameter sets) 0.14...2.0% obs/m 0.03...2.0% obs/m – Fire 2 (5 parameter sets) – Fire 2 (10 parameter sets) 6.0...20% obs/m 2.0...20% obs/m Air inlet pipe Planning Tool ü Communication protocol Display Cerberus PRO – C-NET devices ü ü ü The aspirating smoke detector continually takes air from the monitored room using a connected pipe system with defined aspirating holes. Remote access with CerberusRemote Pipe length Relay outputs 3x2 A / 30 V 4x2 A / 30 V Terminals 0.2...2.5 mm² (30 - 12 AWG) 0.2...2.5 mm² (30 - 12 AWG) Dimensions (WxHxD) 155x280x114 mm 155x280x114 mm Operating current – 150 mA nominal – 250 mA in alarm – 150 mA nominal – 250 mA in alarm Operating temperature -20...+60 °C -20...+60 °C Relative humidity 5...95% rel. (no condensation) 5...95% (no condensation) Protection category IP30 IP30 Data sheet A6V10331032 A6V10331032 Ethernet Security module (firewall) NK8237 Tonality Frequency pattern Sweep from – to 1 Continuous 970 Hz 2 Intermittent 950 Hz 3 Sweep-down 1200 Hz – 500 Hz 4 Slow-whoop Sweep-up, linear 500 Hz – 1200 Hz 5 Pulse tone 500 Hz 6 Intermittent 500 Hz 7 Continuous 500 Hz 8 Alternating 560 Hz 440 Hz 9 Intermittent 420 Hz 10 Slow-whoop Sweep-up, linear 500 Hz – 1200 Hz 11 Intermittent 970 Hz Adjustable FDS221 and FDS229 sound intensity level (typ. values in [dBA/1m]*) Pulse pattern at 32 V 98 88 81 101 92 82 “Evacuate” BS 5839 Part 1 1988 96 87 79 100 91 81 “Alert” BS 5839 Part 1 1988 96 87 79 100 91 80 DIN-Tone DIN33404 Part 3 97 88 81 101 92 82 NEN2575 (Netherlands) 94 85 75 97 88 75 Swedish Standard SS 03 17 11, No. 1 “Imminent Danger” 93 84 75 96 87 75 Swedish Standard SS 03 17 11, No. 6 “Local Warning” 94 85 76 97 88 76 Swedish Standard SS 03 17 11, No. 4 “All clear” 94 85 75 98 89 76 “French fire sound” NF S 32-001-1975 94 85 76 98 89 77 Australia “Alert” AS 2220 -1978 96 89 81 100 93 82 Australia “Action” AS 2220 -1978 99 89 82 102 92 83 ISO 8201 US Temporal Tone LF 1s 1s Backbone (C-WEB/LAN) Ethernet switch FN2008-A1 Norm at 12 V 1s Cerberus Mobile Ethernet switch FN2008-A1 Ethernet switch FN2008-A1 3.5 s Ethernet switch FN2008-A1 0.5 s 0.15 s Manual call point FDM221 Alarm sounder FDS221 0.1s C-NET Sounder base DBS720 FP120-Z1 Power supply kit A (70 W) Metric: 21 mm ID...25 mm OD – 30 m (single pipe length) – 60 m (single pipe length) – 2x25 m (branched pipe – 4 x30 m (branched pipe length) length) Danger management system from Siemens No. Security module (firewall) NK8237 Up to 800 m² Metric: 21 mm ID...25 mm OD Customer network The position and size of the aspirating holes are calculated with the ‚FXS2055 ASD Asyst Tool‘ software. Fire control panel FC723 0.15 s Fire control panel FC724 Fire control panel FC722 Cluster (C-WEB/SAFEDLINK) DC 24 V Fire terminal FT724 Alarm indicator FDCAI221 Heat detector HI722 (max) Smoke detector OP720 Input module FDCI222 Floor repeater display FT2011 Sounder interbase with supplementary optical indication DBS729 Multi-sensor fire detector OH720 C-NET Input/output module FDCIO222 Alarm sounder with supplementary optical indication FDS229-R SWING radio gateway FDCW241 SWING radio neural fire detector FDOOT271 Extinguishing control unit XC10 Fire control panel FC724 ASA neural fire detector OOH740 ASA neural fire and CO detector OOHC740 Smoke detector OP720 www.siemens.com/cerberus Manual release Multi-sensor fire detector OH110 Sinorix extinguishing solution 0.4 s 0.6 s Heat detector HI720 (max + RoR) Stub line 0.65 s 3.75 s C-NET 0.25 s Multi-sensor detector OOH740-A9-Ex 0.5 s Flame detector FDF241-9 SWING radio manual call point FDM273 ASA neural fire detector OOH740 0.1s Fault transmission Alarm transmission Sounder interbase DBS721 FDCC221S Communication interface 0.6 s Fire control panel FC726 Floor repeater terminal FT2010 Aspirating smoke detectors FDA221 FDA241 C-NET Detection modes: Ultra sense Automatic discrimination Robust Powerful control panels, clever fire detectors and smart peripheral devices. This is what our comprehensive Cerberus™ PRO family offers. The brief overview below demonstrates the most important system components. FDA241 Pipe system FDA221 Alarm sounder tones Cerberus PRO – enjoy protecting 0.5 s 1.5 s Manual call point FDM223 Linear smoke detector FDL241-9 Line adapter (Ex) FDCL221-Ex *S ound intensity ±2 dBA Sound intensity depending on the angle, see 'Operating instruction 008109' Mimic display driver FT2001-A1 Samples for all alarm sounder tones are available on the Cerberus PRO Web site. www.siemens.com/cerberus Robust or sensitive? The solution often lies somewhere in between. Sensitive Sensitive Sensitive Sensitive Sensitive PS6 PS9 Robust PS10 High Sensitive Fast (PS9) Robust PS4 Fast Response (PS6) Robust PS2 Balanced CO (PS10) Robust Sensitive Balanced (PS4) Robust PS7 Robust (PS2) Robust PS12 High Compensation (PS7) Robust PS5 Sensitive Suppression CO (PS12) Robust PS8 Sensitive Suppression (PS5) Robust Sensitive High Suppression (PS8) Application area Application area Application area Application area Application area Application area Application area Application area Application area For operating conditions susceptible to heavy optical deceptive phenomena. Examples include dance floors in discotheques (deceptive phenomena: dry ice) or churches during special services (deceptive phenomena: frankincense). Difficult environments subject to heavy deceptive phenomena. Application examples include canteen kitchens or manufacturing areas with operational-related deceptive aerosols. Difficult environments subject to heavy deceptive phenomena. Application examples include manufacturing areas with operational-related aerosols. Additional separate CO toxic gas detection and environmental monitoring. Applications with deposits resulting from excessive dust or dirt over a long-time period. Here, optical detectors usually reach their limit quickly, resulting in a reduced operational lifetime. Difficult environmental conditions. Examples are event locations or underground garages with moderate deceptive phenomena and risks to individuals. Standard applications. Rooms with moderate deceptive phenomena. Rooms where an increased CO concentration in the event of a fire is possible. Moderate deceptive phenomena. Rooms in which sensitive and quick detection is essential such as rooms with high ceilings, warehouses with flammable material (increased risk of fire) and application areas where the detectors trigger an extinguishing system. Rooms in which an especially high sensitivity to smoldering and open fires is required. Examples include museums with high ceilings, clean production halls or applications where adequate life protection can only be ensured by the fastest possible detection. Due to special thermal algorithms, usage at low temperatures is also possible. Our world is undergoing changes that force us to think in new ways: demographic change, urbanization, global warming and resource shortages. Maximum efficiency has top priority – and not only where energy is concerned. In addition, we need to increase comfort for the well-being of users. Also, our need for safety and security is constantly growing. For our customers, success is defined by how well they manage these challenges. Siemens has the answers. “We are the trusted technology partner for energy-efficient, safe and secure buildings and infrastructure.” Description In this parameter set, the signal from the smoke sensor will not be allowed to create a fire alarm signal until a simultaneous increase in the thermal signal is also detected. In the event of dry ice, there is no temperature increase and the detector will not create an unwanted alarm. With a rise in temperature of only 8K (open fire), the optical sensors will be further analyzed and if the signal corresponds to a fire, an alarm will be triggered. In addition, the detector will also trigger an alarm as a rate-of-rise heat detector or if its static temperature limit is exceeded. Description Highly robust behavior, therefore very suitable for applications with deceptive phenomena such as steam, heavy cigarette smoke or exhaust gases. At the same time, the detector reacts with the ASA parameter set quickly and reliably in case of a real fire due to the dynamic influencing of the parameters. Description Highly robust behavior, therefore very suitable for applications with deceptive phenomena such as steam, cigarette smoke, etc. At the same time, the detector reacts with the ASA parameter set quickly and reliably in case of a real fire due to the dynamic influencing of the parameters. Sensitivity is also influenced by the CO concentration. Separate CO alarming and control for the detection of unhealthy or dangerous carbon monoxide buildup. Separate signaling of environmental thermal thresholds. Description This parameter set is identical to the Robust setting except that the drift compensation is extended. This parameter set is therefore especially suited for rooms in which a lot of dust and other deposits can be expected to build up over a period of time. The detector maintains the set detector sensitivity and resistance to deceptive phenomena. The detector reacts quickly and reliably in case of a real fire. Description Designed for robust behavior. This ASA parameter set is particularly suitable for applications with deceptive phenomena such as cigarette smoke, dust and exhaust gases. At the same time, the detector reacts very quickly and reliably in case of a real fire. Compared to the ‘Suppression (PS5)’ parameter set, the ‘Robust (PS2)’ parameter set may be used to improve detection speed on higher ceilings while still retaining sufficient resistance to false alarms. Description For use in normal environments. This parameter set has a balanced response characteristic; sensitive in case of a fire but still tolerant of transient deceptive phenomena. Due to its distinct dynamic, the detector reacts quickly to open fires as well as smoldering fires. This ASA parameter set reacts robustly to deceptive phenomena such as cigarette smoke or small amounts of steam. Description Using the three criteria: smoke, heat and CO the device is more sensitive to fires creating CO than the parameter set ‘Balanced (PS4)’ without the CO signal. The device is robust with deceptive phenomena such as cigarette smoke or a small amount of steam. This parameter also offers early alarming in the event of fires generating a large amount of CO, e.g. mattress fires. Additional information Description This parameter set reacts in a fast and sensitive manner. It is thus especially suited for rooms without deceptive phenomena, where the priority is on detecting fires as early as possible. Expert advice Description This parameter set allows for the fastest possible detection for both open and smoldering fires. It is therefore intended for use in clean environments with no deceptive phenomena. The high thermal influence from open fires transports the dark smoke particles that are typical for this kind of fire quickly to the ceiling. Due to the backward scattering and the “Fast Response” setting, the detector is sensitive. This makes the detector a perfect replacement in situations where ionization detectors would normally have been considered optimal. This parameter set is often used when the system is set in unmanned mode (e.g. at night). Expert advice “High Suppression” has clear advantages over traditional concepts where smoke detection is turned off completely and replaced by thermal detection during events where dry ice is used. This parameter set allows much faster detection than switching to purely thermal detection. This enhances safety at critical times where visibility is reduced and large numbers of people are in attendance. Further options include the ability to switch between parameter sets so that a more sensitive detection mode can be used when no dry ice is likely. The detector complies with the norm EN 54-5 and in some jurisdictions heat detector spacing may be applicable. Complies with the norm EN 54-5 Complies with the norm EN 54-5, EN 54-7 Complies with the norm EN 54-5, EN 54-7 Complies with the norm EN 54-5, EN 54-7 Complies with the norm EN 54-5, EN 54-7 Complies with the norm EN 54-5, EN 54-7 Complies with the norm EN 54-5, EN 54-7 Complies with the norm EN 54-5, EN 54-7 Complies with the norm EN 54-5, EN 54-7 Application examples Application examples Application examples Application examples Application examples Application examples Multi-purpose halls, theater stages, churches, dance floors in discotheques Canteen kitchens, production areas with operational-related deceptive phenomena Production areas with operational-related deceptive phenomena Paper mills, carpenters workshops, textile production, recycling plants Event locations, conference rooms, smoking rooms, gastronomy, industry, production, underground garages Offices, open-plan offices, hallways, hotel rooms, out of hours use in harsh environment areas Application examples Application examples Application examples Same as for ‘Balanced (PS4)’, but with increased sensitivity to smoldering fires creating CO gas High-ceilinged rooms, storage rooms/warehouses with flammable material, IT rooms and control of extinguishing systems Hospital rooms, museums, operating rooms, cold storage, high-ceilinged rooms, when highly sensitive detection is of great importance Specifications are subject to change without notice. © Siemens Switzerland Ltd, 2015 • Order no. 0-92314-en • 01507 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. The document contains a general product overview. Availability can vary by country. For detailed product information, please contact the company office or authorized partners. Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel +41 41 724 24 24 Cerberus PRO Planning Tool C-NET devices Cerberus PRO fire detectors Sounder base DBS720 Sound level: 88 dBA/1 m Detector base DB721 Detector base DB722 Flame detector base FDFB291 Art. no.: S54319-F11-A1 Art. no.: S54319-F19-A1 Art. no.: A5Q00003310 Art. no.: S54319-F5-A1 Cluster (C-WEB/SAFEDLINK) Shared properties FT2010 and FT2011: –B acklit display with plain text (6 lines of 40 characters each) –P ower supply and communication (individual addressed) via C-NET, additional DC 24 V feed possible – 207x282x79 mm (HxWxD) –M ax. 8 FT2010/FT2011 per FC721/FC722 –M ax. 16 FT2010/FT2011 per FC724 – Max. 50 FT2010/FT2011 per FC726 Fire control panel FC724 Conventional Art. no.: A5Q00003941 or Fire control panel FC723 Linear smoke detector base FDLB291 Addressable Single action DMA1104D Protection category: IP54 Double action DMA1103D Protection category: IP54 Art. no.: A5Q00005925 Art. no.: A5Q00004470 Manual call point DM1103 (Ex) Infrared flame detector unit collective “Ex” DF1101-Ex Art. no.: BPZ:5222870001 Art. no.: BPZ:5162220001 or Fire control panel FC722 Flame detector FDF241-9 – For inside and outside applications – Three infrared sensors Linear smoke detector FDL241-9 Art. no.: S54329-F8-A1 Art. no.: A5Q00003006 Art. no.: A5Q00002298 Safety barrier SB3 Fire control panel FC722 ASA neural fire detector OOH740 Two optical sensors, two heat sensors, seven parameter sets Art. no.: A5Q00014104 Art. no.: S54320-F7-A3 ASA neural fire and CO detector OOHC740 Two optical sensors, two heat sensors, one carbon monoxide sensor, nine parameter sets Multi-sensor fire detector OH720 Combined optical and thermal sensors, two parameter sets Smoke detector OP720 Two parameter sets Heat detector HI722 (max) One parameter set (static) Art. no.: S54310-F1-A1 Art. no.: S54310-F3-A1 Heat detector HI720 (max + RoR) Two parameter sets (rate of rise and static) up to 1 00 m Base for infrared flame detectors DF119x DFB1190 Input/output module “transponder” FDCIO223 Air sampling smoke detection kit FDBZ290 Art. no.: S24218-B102-A1 Art. no.: S54319-S32-A1 Detector base DB721 Art. no.: S54319-F11-A1 Art. no.: S54320-F8-A3 Base attachment wet BA721 Detector base seal RS720 Art. no.: S54319-F8-A1 Short-distance filter 7 – 10 m DLF1191-AA Art. no.: BPZ:3950450001 Art. no.: BPZ:4933030001 Art. no.: S54319-F29-A1 Floor repeater display FT2011-A1 Long-distance reflector DLR1191 (Prism) For distances between 20 and 100 meters. ASA neural fire detector OOH740 Art. no.: S54320-F7-A3 Art. no.: BPZ:4787710001 Designation plate FDBZ291 Art. no.: A5Q00017706 Art. no.: S54370-F6-A1 Art. no.: S54319-F9-A1 Alarm indicator FDAI92 Art. no.: S54370-F3-A1 Mimic display driver FT2001-A1 LED flat cable 24 LEDs F50F410 Additional frame AI330 Art. no.: A5Q00014417 Art. no.: BPZ:5291410001 Art. no.: BPZ:3169430001 Alarm indicator FDAI91 Alarm indicator FDAI93 Art. no.: S54370-F9-A1 Art. no.: S54370-F5-A1 Base attachment BA720 Protection cage DBZ1194 Ball and socket joint MWV1 Art. no.: BPZ:4677110001 Art. no.: BPZ:3674840001 Short-distance filter 5 – 8 m DLF1191-AB Art. no.: BPZ:4933160001 Art. no.: S54319-F20-A1 Line adapter (Ex) FDCL221-Ex Art. no.: S54329-F4-A1 Output module (230 V) FDA221 FCA1209-Z1 Art. no.: S54333-F15-A1 The output module is FDA241 directly connected with the monitored output line and Art. no.: S54333-F17-A1 provides one potential-free contact. It is an output Accessories: module for the control of Communication interface ventilation‚ air conditioning‚ elevators‚ etc. FDCC221S Adapter FDUD491 Detector tester for heat detectors RE7T Line tester FDUL221 Art. no.: S54319-F18-A1 Art. no.: S54370-S3-A1 Art. no.: A5Q00004397 Detector exchanger DX791 Detector tester for linear smoke detectors RE10 Telescope rod FDMU291 Art. no.: S54319-F6-A1 Art. no.: BPZ:3685190001 Art. no.: A5Q00004996 Multi-line separator module FDCL221-M Up to 9 stubs The multi-line separator has altogether nine integrated line separators with one individual addressing each and one LED indicator per separator. It can be connected to two separate C-NET loops. Input module FDCI221 – 1 monitored input Art. no.: S54312-F1-A1 Art. no.: A5Q00002369 Extinguishing panel standard XC1001-A The XC10 combined extinguishing and detection panel can be fully integrated into all Cerberus PRO systems via the FDCIO222 as an independent unit. All relevant incidents are forwarded to the connected control panels. The extinguishing control unit XC10 and the connected extinguishing valves must have a separate power supply. For XC10 variants please see separate XC10 Planning Tool. Test lamp for flame detectors ‘Ex’ StabexHF Scorpion controller SCORP 8000 Art. no.: BPZ:3680300001 Art. no.: BPZ:4620910001 Art. no.: S54333-C91-A1 Testifire 1001-045 ST test kit RE8ST Test lamp for flame detectors LE3 Scorpion ASD head unit SCORP 2001 Art. no.: S54370-S23-A1 Art. no.: BPZ:3669510001 Art. no.: S54333-S90-A1 Relay outputs: – 4 potential-free working/rest contacts Fire damper 4 isolated control outputs Rain hood DFZ1190 Detector heating DLH1191A Art. no.: BPZ:5302660001 Art. no.: BPZ:4787970001 Fire control Contact loading: – AC 250 V/4 A – DC 30 V/4 A Art. no.: A5Q00002369 Input module FDCI222 – 4 monitored inputs 4 isolated control inputs Art. no.: A5Q00001984 Short-distance reflector DLR1193 For distances between 10 and 30 meters. FP120-Z1 Power supply kit A (70 W) The standalone power supply converts the mains voltage to system voltage and charges the batteries. Art. no.: BPZ:4787840001 Input/output module “transponder” FDCIO223 The module has two inputs/outputs and is used for – connecting conventional detectors – connecting detectors by means of safety barriers in explosionprotected areas – controlling alarm devices (flashing lights, sirens) – for monitored control (e.g. fire dampers) Housing FDCH221 IP65 Art. no.: S54312-F3-A1 Conventional line Conventional detectors Testifire 2001-045 STCO test kit RE8STCO 2 inputs or 2 outputs – requires DC 24 V power supply unit Art. no.: S54370-S24-A1 Art. no.: S24218-B102-A1 Alarm equipment (audible/visible) Sounder base DBS720 Sound level: 88 dBA/1 m Art. no.: S54319-F5-A1 Detector base DB721 Art. no.: S54319-F11-A1 or Detector base DB722 Sounder base FDB221 Art. no.: S54319-F19-A1 Art. no.: A5Q00001664 or Manual call points and accessories Sounder base flat FDB222 Art. no.: S54319-F1-A1 Manual call point FDM221 Standard, available in different colors. Sounder interbase (C-NET) DBS721 Sound level: 87 dBA/1 m Art. no.: S54372-F13-A1 (Picture shows product with blanking plate BPZ20) Art. no.: S54390-C1-A1 Sounder interbase with supplementary optical indication (C-NET) DBS729 Sound level: 87 dBA/1 m Alarm sounder FDS221-W Sound level: 99 dBA/1 m Alarm sounder FDS221-R Sound level: 99 dBA/1 m Art. no.: A5Q00006711 Art. no.: A5Q00004117 Alarm sounder with supplementary optical indication FDS229-R Sound level: 99 dBA/1 m Alarm sounder with supplementary optical indication FDS229-A Sound level: 99 dBA/1 m Art. no.: A5Q00023093 Art. no.: A5Q00023092 Manual call point FDM225 Resettable, available in red and can be used for flush mounting. Alarm indicator (addressable) FDCAI221 Manual call point with resettable plastic element FDM225-RP Art. no.: S54370-F10-A1 Art. no.: A5Q00012020 Art. no.: S54372-F14-A1 Manual call point with resettable plastic element incl. back box FDM226-RP Manual call point FDM231-RP Standard, available in red. Manual call point FDM224 IP44 or IP64, with direct operation available in different colors. Manual call point FDM223 IP44 or IP64, with indirect alarm actuation, available in different colors. Manual call point FDM224H Heavy Duty, IP44 or IP64, with direct alarm actuation. Manual call point FDM223H Heavy Duty, IP44 or IP64, with indirect alarm actuation. Art. no.: A5Q00002451 Manual call point complete Art. no.: S54311-F11-A1 Art. no.: S54311-F8-A1 Manual call point with glass plate FDM225-RG Manual call point with glass plate incl. back box FDM226-RG Electronic switching unit incl. key FDMK231 FDME231 Art. no.: A5Q00013434 Art. no.: A5Q00013435 Art. no.: S54311-B14-A1 Electronic switching unit FDME224 Electronic switching unit FDME223 Electronic switching unit FDME224 Electronic switching unit FDME223 Art. no.: A5Q00009392 Art. no.: A5Q00003087 Art. no.: A5Q00009392 Art. no.: A5Q00003087 Housing: Housing: C-NET Housing red with key FDMH291-R Housing red FDMH292-R Housing red FDMH292-R Art. no.: A5Q00005525 Art. no.: A5Q00005525 The C-NET is a modern, multi-purpose bus system. It allows rapid, fail-safe communication between the Cerberus PRO bus elements and the fire control panel. Housing yellow Housing red FDMH293-R Housing yellow FDMH293-Y Housing green FDMH293-G Housing blue FDMH293-B Housing orange FDMH293-O Housing red FDMH297-R Art. no.: A5Q00002217 with key FDMH291-Y Art. no.: A5Q00004023 Art. no.: A5Q00004908 Art. no.: A5Q00004911 Art. no.: A5Q00004909 Art. no.: S54311-F2-A1 Art. no.: S54311-B7-A1 Backbone (C-WEB/LAN) Network for connecting clusters Cluster (C-WEB/SAFEDLINK)Network for connecting panels C-NET Network for connecting Cerberus PRO addressable devices C-NET-Ex Network for connecting Cerberus PRO addressable Ex devices Sealing element FDBZ295 (only together with base FDB221) BP720 Blanking plate (only for DBS721 and DBS729) Housing green with key FDMH291-G Art. no.: S54319-F10-A1 Art. no.: S54372-B12-A1 Art. no.: A5Q00004981 Designation plate FDBZ291 Base attachment wet FDB295 Housing blue with key FDMH291-B Art. no.: A5Q00002621 Art. no.: S54319-F2-A1 Art. no.: A5Q00004980 Accessories: Accessories: Accessories: Accessories (for FDM224 and FDM223): Back box FDMH295-R Protective cover FDMC295 Back box red FDMH231-S-R Protection seal DMZ1197-AD Art. no.: BPZ:5470680001 Protection seal Protective cover DMZ1197-AC Art. no.: BPZ:5223550001 DMZ1197-AD Art. no.: A5Q00013440 Art. no.: S54311-B12-A1 Locking plug M20 (1 hole) Art. no.: A5Q00013437 Back box with holes and grommet FDMH295-S Screwed cable gland M20 x 1.5 Designation plate DBZ1193A Accessories: Art. no.: A5Q00013438 Art. no.: A5Q00001603 Art. no.: BPZ:4864330001 Protective cover FDMC291 Protective cover FDMC295 Art. no.: A5Q00004478 Art. no.: A5Q00001644 Art. no.: A5Q00013440 Art. no.: A5Q00004479 Detector locking device FDBZ293 Art. no.: S54319-F9-A1 Art. no.: A5Q00005035 Base FDB271 Art. no.: S54319-F12-A1 Neural radio fire detector FDOOT271 Radio manual call point FDM273 Art. no.: S54313-F1-A1 Art. no.: S54323-B109-A1 Base attachment FDB291 Detector locking device LP720 SWING devices are communicating via multi-band (433/868 MHz) multi-hop mesh technology Housing red‚ with glass and key FDMH273-R Art. no.: A5Q00004979 Legend for the designation of fire detectors: Radio gateway FDCW241 The radio gateway FDCW241 enables to bidirectionally connect up to 30 battery-powered SWING radio devices. Art. no.: S54370-F11-A1 Manual call point complete Housings with glass and key (FDM224 and FDM223): Sounder accessories Manual call point FDM243H Heavy Duty, IP66, with direct alarm actuation. SWING radio fire detection Art. no.: A5Q00013436 Electronic switching unit FDME221 Shared characteristics: – 11 different tones, incl. “Evacuate” as specified in DIN 33404-3 – Different volume and sound programmable for prealarm and main alarm – Loop-powered Manual call point FDM226 Resettable and IP66, available in red. Housings: Characteristics: – Use of all cable types (shielded or unshielded) – Integration of star-shaped cable networks without modifications to cable network – Acoustic and visual signaling on the loop – Up to 40 T-taps – Up to 252 bus elements on one loop – Cable lengths up to 3.3 km with up to 252 bus elements – 2-wire loop – Power supply to all bus elements via the C-NET (except transponder FDCIO223, LaserFOCUS, extinguishing control unit XC10, ASD FDA221, FDA241) – Integrated isolator in every loop participant Input/output module FDCIO222 – 4 monitored inputs 4 isolated control inputs Mid-distance reflector DLR1192 For distances between 30 and 65 meters. Art. no.: S54400-S122-A1 Art. no.: S54312-F6-A1 Input/output module FDCIO222 Detector tester for smoke detectors RE6 Relay outputs: – 1 output – Relay output DC 30 V/2 A rated – Can be configured as monitored, but a separate DC 24 V power supply is required Art. no.: S54312-F2-A1 Test equipment Art. no.: A5Q00004011 Input/output module FDCIO221 – 1 monitored input Fire control Art. no.: BPZ:4788490001 Line separator FDCL221 Only required to separate 2 adjacent stubs Art. no.: S54329-F5-A1 Art. no.: S54319-F1-A1 Power supply kit FP120-Z1 Art. no.: A5Q00004439 Detector locking device LP720 Manual call point FDM223-Ex Detector base flat, addressable FDB222 Art. no.: S54400-B124-A1 Detector heating FDBH291 Art. no.: A5Q00002621 Art. no.: A5Q00001664 Aspirating smoke detectors Art. no.: S54310-F2-A1 Mounting bracket MV1 Art. no.: S54370-F4-A1 Alarm indicator FDAI93-Ex Art. no.: BPZ:5165360001 Art. no.: S54310-F4-A1 Detector base accessories Detector base addressable FDB221 Multi-sensor detector OOH740-A9-Ex Art. no.: BPZ:4837000001 Floor repeater terminal FT2010-A1 Alarm indicator FDAI92-Ex Art. no.: S54329-F8-A1 Multi-sensor detector OOH740-A9-Ex Fire control panel FC726 Ex zone C-NET-Ex Cerberus PRO control panels Back nut M20 Art. no.: A5Q00006735 Accessories: Accessories: Switching unit with indirect alarm actuation FDME273 Protection seal DMZ1197-AD Art. no.: S54323-B108-A1 Art. no.: BPZ:5470680001 Art. no.: BPZ:5470680001 Protective cover DMZ1197-AC Protective cover DMZ1197-AC Protective cover DMZ1197-AC Art. no.: 5223550001 Art. no.: BPZ:5223550001 Art. no.: BPZ:5223550001 Screwed cable gland M20 x 1.5 Screwed cable gland M20 x 1.5 Art. no.: A5Q00004478 Art. no.: A5Q00004478 Battery BAT3.6-10 Art. no.: S54370-Z11-A1 © Siemens 2013 © Siemens 2015
Similar documents
Cerberus FIT product catalog - Siemens Building Technologies
included. Labelling: Dutch only.
More information