IT T Goulds Pumps G&L Series SSH S & M-Group 316 Stainless Steel End Suction Pumps www.goulds.com Engineered for life Commercial Water A Full Range of Product Features Superior Materials of Construction: AISI Type 316L stainless steel pump parts for reduced corrosion and improved strength and ductility. Frame Mounted Design: Flexibility of installation and driver arrangements. Back Pull-Out Design: Simplifies maintenance when used with spacer type coupling. Drive Motors: Standard NEMA design T-frame or JM motors in single or three phase. Suction and Discharge Flanges: Mate with ANSI class 150 flanges. Close-Coupled Design: Compact design saves space and simplifies maintenance. Cast Iron Power Frame: Rigidly supported, grease lubricated ball bearing assembly. Mechanical Seal: Standard John Crane Type 21 mechanical seal. GOULDS PUMPS Commercial Water 2 Performance Coverage, 3500 and 1750 RPM METERS FEET 600 175 TOTAL DYNAMIC HEAD 150 125 3500 RPM 500 400 27SH 100 300 24SH 28SH 11SH 25SH 75 200 23SH 10SH 50 22SH 7SH 8SH 9SH 25 100 6SH 5SH 4SH 0 0 0 0 METERS 100 200 20 300 40 80 60 500 400 100 600 700 120 140 160 CAPACITY – U.S. GPM 800 180 900 200 1000 220 1100 240 1200 260 m3/hr FEET 150 1750 RPM 40 TOTAL DYNAMIC HEAD 125 30 100 75 20 24SH 11SH 50 25 28SH 10SH 7SH 10 27SH 25SH 8SH 22SH 23SH 9SH 6SH 5SH 4SH 0 0 0 0 100 20 200 40 300 60 400 80 100 CAPACITY – U.S. GPM 500 120 600 140 700 800 160 m3/hr 180 GOULDS PUMPS Commercial Water 3 SSH S/M-Group Numbering System Example Product Code 24 SH 1 Q 1 2 A 0 Mechanical Seals and O-Ring 0 = Pre-engineered standard For optional mechanical seal modify catalog order no. with seal code listed below. John Crane Type 21 Mechanical Seal Seal Code 0 2 5 Part No. Rotary Stationary Carbon Sil-Carb Sil-Carb Sil-Carb Elastomers Metal Parts Viton EPR Viton 180-210 Frames 250-360 Frames 10K27 10K19 10K64 10K45 10K20 10K65 316 SS Impeller Option Code For optional impeller diameters modify catalog order no. with impeller code listed below. Select optional impeller diameter from pump performance curve. Impeller Code A B C D E F G H J K L Pump Size 9SH 10SH 11SH 4SH 1 x 2-6 1 x 2-8 1 x 2-10 1½ x 2½-6 1½ x 2½-8 2 x 2½-6 Dia. 65⁄8 67⁄16 511⁄16 53⁄8 Dia. 827⁄64 81⁄16 711⁄16 73⁄8 71⁄8 Dia. 103⁄32 917⁄32 91⁄8 8¾ Dia. 6¾ 63⁄8 61⁄16 55⁄8 55⁄16 411⁄16 43⁄8 43⁄16 37⁄8 7SH Dia. 81⁄4 713⁄16 7 6¾ 67⁄16 61⁄8 5SH Dia. 67⁄8 67⁄16 513⁄16 5½ 51⁄8 413⁄16 47⁄16 4¼ Motor Enclosure 1 = ODP 2 = TEFC 3 = Explosion Proof 4 = ODP Premium Eff. Motor Voltage 1 = 115/208-230 2 = 115/230 8SH 6SH Dia. 8¼ 7¾ 7½ 73⁄16 67⁄8 63⁄16 Dia. 75⁄16 71⁄8 615⁄16 611⁄16 63⁄8 61⁄16 55⁄8 23SH 3x4–8 Dia. 91⁄16 8¾ 8½ 8¼ 77⁄8 7½ 71⁄8 611⁄16 6½ Dia. 91⁄16 811⁄16 87⁄16 81⁄16 711⁄16 7½ 71⁄8 67⁄8 6½ 6 5½ 24SH 25SH 27SH 28SH 1½ x 2½ – 10 2 x 2½ – 10 2½ x 3 – 10 3 x 4 – 10 Dia. 97⁄8 9½ 93⁄16 87⁄8 89⁄16 8¼ Dia. 97⁄8 9½ 91⁄8 813⁄16 83⁄16 715⁄16 711⁄16 Dia. 103⁄8 915⁄16 99⁄16 9¼ 8¾ Dia. 105⁄8 10¼ 913⁄16 97⁄16 91⁄16 811⁄16 5 = TEFC Premium Eff. 6 = XP Premium Eff. 7 = Wash down 3 = 230 4 = 230/460 5 = 208-230/460 6 = 460 HP Rating, Potencia nominal C = ½ F = 1.5 J = 5 M = 15 D = .75 G = 2 K = 7.5 N = 20 E=1 H =3 L = 10 P = 25 Q = 30 R = 40 S = 50 Driver: Hertz/Pole/RPM 1 = 60/3500/1 3 = 60/1750/1 2 = 60/3500/3 4 = 60/1750/3 5 = 50/2900/1 6 = 50/2900/3 4 = 1½ x 2½ – 6 7 = 1½ x 2½ – 8 5 = 2 x 2½ – 6 24 = 1½ x 2½ – 10 28 = 3 x 4 – 10 7 = 575 T = 60 U = 75 V = 100 Material SH = 316L Stainless steel Pump Size 9=1x2–6 10 = 1 x 2 – 8 11 = 1 x 2 – 10 23 = 3 x 4 – 8 27 = 2½ x 3 – 10 22SH 2 x 2½-8 2½ x 3-6 2½ x 3 – 8 8 = 2 x 2½ – 8 6 = 2½ x 3 – 6 22 = 2½ x 3 – 8 25 = 2 x 2½ – 10 Frame Options Substitute Description 7 FRM2 FRM3 /8" Imp. Bore 11/4" Imp. Bore NOTE: Not all combinations of motor, impeller and seal options are available for every pump model. Please check with G&L on non-cataloged numbers. GOULDS PUMPS Commercial Water 4 Performance Curves – 60 Hz, 3500 RPM METERS 60 Model SSH / 9SH Size 1 x 2-6 RPM 3500 Curve CN0619R00 FEET Optional Impeller Impeller Code 200 Standard Dia. HP Rating 5' NPSHR – FEET 39 A 65/8" DIA. 50 7 B 6 /16" 10' 150 TOTAL DYNAMIC HEAD (H) A B C D 8' 49 54 40 56 EFF% C 511/16" 65⁄8" 67⁄16 511⁄16 53⁄8 5 5 3 3 NOTE: Pump will pass a sphere to 1⁄8" diameter. D 53/8" 30 100 20 5 HP 50 3 HP 10 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 25 0 50 75 10 5 100 125 20 15 25 U.S. GPM 150 30 m3⁄ hr CAPACITY (Q) METERS 90 A 827/64" DIA. 70 42 10' 14' C 711/16" 200 A B C D E 6' NPSHR – FEET 33 250 B 81/16" TOTAL DYNAMIC HEAD (H) Impeller Code 300 80 60 Optional Impeller Model SSH / 10SH Size 1 x 2-8 RPM 3500 Curve CN0613R00 FEET 18' 47 22' D 73/8" 827⁄64" 81⁄16 711⁄16 73⁄8 71⁄8" 10 10 7½ 7½ 7½ NOTE: Pump will pass a sphere to 1⁄8" diameter. 49 42 EFF% E 71/8" 50 Standard Dia. HP Rating 150 40 30 100 NOTE: Not recommended for operation beyond printed H-Q curve. 20 71/2 HP 50 0 0 25 5 50 10 75 15 100 20 125 25 150 30 35 10 HP 175 U.S. GPM 200 40 m3⁄ hr CAPACITY (Q) GOULDS PUMPS Commercial Water 5 Performance Curves – 60 Hz, 3500 RPM METERS Optional Impeller Model SSH / 11SH Size 1 x 2-10 RPM 3500 Curve CN0616R00 FEET Impeller Code 450 130 120 NPSHR – FEET 3 400 A 10 /32" DIA. 30 22’ 38 TOTAL DYNAMIC HEAD (H) 110 17 350 B 9 /32" 25' 43 27' 100 45 C 91/8" 90 80 Standard Dia. HP Rating 300 A B C 103⁄32" 917⁄32 91⁄8 20 15 15 D 8¾ 15 NOTE: Pump will pass a sphere to 1⁄8" diameter. 29' 43 EFF% D 83/4" 250 70 60 200 10 HP 50 150 20 HP 40 30 100 15 HP NOTE: Not recommended for operation beyond printed H-Q curve. 20 50 0 25 0 50 5 10 75 100 15 125 20 150 30 25 175 U.S. GPM 200 35 40 m3⁄ hr CAPACITY (Q) METERS Model SSH / 4SH Size 11/2 x 21/2- 6 RPM 3500 Curve CN0488R01 FEET 60 175 55 A 6 /4" DIA. 8' 59 61 50 3 B 6 /8" 150 TOTAL DYNAMIC HEAD (H) Impeller Code 63 65 C 61/16" 65 12' 125 D 55/8" 63 61 EFF% E 55/16" 30 Standard Dia. HP Rating 5' NPSHR – FEET 3 40 Optional Impeller 100 10 HP F 411/16" 6¾" B C D E F G H J 63⁄8 61⁄16 55⁄8 55⁄16 411⁄16 43⁄8 43⁄16 33⁄8 10 7½ 7½ 5 5 3 3 2 2 NOTE: Pump will pass a sphere to 3⁄16" diameter. 75 G 43/8" 7 / HP 1 2 20 A H 43/16" 5 HP 50 J 37/8" 3 HP 10 25 0 0 0 0 2 HP NOTE: Not recommended for operation beyond printed H-Q curve. 50 10 100 20 150 30 200 40 250 U.S. GPM 50 60 m3⁄ hr CAPACITY (Q) GOULDS PUMPS Commercial Water 6 Performance Curves – 60 Hz, 3500 RPM METERS Model SSH / 7SH Size 11/2 x 21/2-8 RPM 3500 Curve CN0491R00 FEET 50 250 B 713/16" TOTAL DYNAMIC HEAD (H) 55 56 57 225 8' 58 59 10' 200 C 7" 14' D 63/4" 50 175 E 67/16" 150 40 30 20 Standard Dia. HP Rating 40 80 60 Impeller Code 6' NPSHR – FEET 1 275 A 8 /4" DIA. 70 Optional Impeller 59 8¼" 713⁄16 C D E 7 6¾ 67⁄16 15 15 10 10 7½ F 61⁄8 7½ NOTE: Pump will pass a sphere to 3⁄16" diameter. 58 F 61/8" A B 57 EFF% 15 HP 125 100 10 HP 71⁄2 HP 75 50 10 0 25 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 25 0 50 75 10 100 150 125 20 175 30 200 225 40 275 U.S. GPM 250 50 60 m3⁄ hr CAPACITY (Q) METERS Model SSH / 5SH Size 2 x 21/2-6 RPM 3500 Curve CN0494R01 FEET 60 50 A 67/8" DIA. Optional Impeller Impeller Code 6' NPSHR – FEET 60 175 64 B 67/16" 50 10' 66 67 TOTAL DYNAMIC HEAD (H) 150 14' 68 13 40 C 5 /16" 125 68 19' 67 D 51/2" 66 EFF% 1 30 100 75 Standard Dia. HP Rating E 5 /8" F 413/16" 67⁄8" 67⁄16 513⁄16 5½ 51⁄8 413⁄16 47⁄16 4¼ 15 15 10 10 7½ 7½ 5 5 NOTE: Pump will pass a sphere to 5⁄32" diameter. 15 HP G 47/16" A B C D E F G H 20 H 41/4" 10 HP 50 71⁄2 HP 10 25 0 0 0 0 5 HP NOTE: Not recommended for operation beyond printed H-Q curve. 50 100 20 150 200 40 250 300 60 350 80 400 U.S. GPM 100 m3⁄ hr CAPACITY (Q) GOULDS PUMPS Commercial Water 7 Performance Curves – 60 Hz, 3500 RPM Model SSH / 8SH Size 2 x 21/2- 8 RPM 3500 Curve CN0497R01 METERS FEET 90 300 Optional Impeller Impeller Code 8' NPSHR – FEET 50 A 81/4" DIA. 60 10' 65 80 250 TOTAL DYNAMIC HEAD (H) A B C D E F 69 70 71 B 73/4" 13' C 71/2" 16' 3 D 7 /16" 60 200 71 E 67/8" 21' 69 50 150 8¼" 7¾ 7½ 73⁄16 67⁄8 63⁄16 25 20 20 15 15 10 NOTE: Pump will pass a sphere to ¼" diameter. 65 EFF% F 63/16" Standard Dia. HP Rating 40 25 HP 30 10 HP 100 20 HP 15 HP 20 50 10 0 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 50 100 0 200 150 20 250 40 300 350 60 400 U.S. GPM 80 100 m3⁄ hr CAPACITY (Q) METERS Model SSH / 6SH Size 21/2 x 3- 6 RPM 3500 Curve CN0500R00 FEET 80 Optional Impeller Impeller Code 7' NPSHR – FEET 250 A B C D E F G 60 70 8' A 75/16" DIA. TOTAL DYNAMIC HEAD (H) 65 60 200 B 71/8" C 615/16" 70 70 10' 68 D 611/16" E 63/8" 50 13' 66 15' 20' 150 F 61/16" 65 40 Standard Dia. HP Rating 75⁄16" 71⁄8 615⁄16 611⁄16 63⁄8 61⁄16 55⁄8 25 25 20 20 15 15 10 NOTE: Pump will pass a sphere to 5⁄16" diameter. 25' G 55/8" 63 30 100 60 EFF% 50 20 HP 20 25 HP 15 HP 10 0 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 100 25 200 50 300 10 HP 400 75 600 500 100 125 700 150 U.S. GPM m3⁄ hr 175 CAPACITY (Q) GOULDS PUMPS Commercial Water 8 Performance Curves – 60 Hz, 1750 RPM FEET 50 Optional Impeller Model SSH / 9SH Size 1 x 2-6 RPM 1750 Curve CN0620R00 Impeller Code Standard Dia. HP Rating NPSHR – FEET A 65/8" DIA. 50 55 40 TOTAL DYNAMIC HEAD (H) A B C D 4' B 67/16" 5' 56 6' 8' C 511/16" 55 EFF% 3 30 D 5 /8" 20 3 1 65⁄8" 67⁄16 511⁄16 53⁄8 ¾ ¾ ½ ½ NOTE: Pump will pass a sphere to 1⁄8" diameter. ⁄4 HP ⁄2 HP 10 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 10 20 30 40 50 70 U.S. GPM 80 60 CAPACITY (Q) FEET Optional Impeller Model SSH / 10SH Size 1 x 2-8 RPM 1750 Curve CN0614R00 Impeller Code 70 A 827/64" DIA. 4' NPSHR – FEET 5' B 81/16" 42 60 6' TOTAL DYNAMIC HEAD (H) C 711/16" 47 8' 50 49 EFF% D 73/8" 40 Standard Dia. HP Rating A 827⁄64" 1½ B C D E 81⁄16 711⁄16 73⁄8 71⁄8 1½ 1 ¾ ¾ NOTE: Pump will pass a sphere to 1⁄8" diameter. E 71/8" 11⁄2 HP 30 3 1 HP ⁄4 HP 20 10 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 10 20 30 40 50 60 70 U.S. GPM 80 CAPACITY (Q) GOULDS PUMPS Commercial Water 9 Performance Curves – 60 Hz, 1750 RPM Optional Impeller Model SSH / 11SH Size 1 x 2-10 RPM 1750 Curve CN0617R00 FEET Impeller Code 120 Standard Dia. HP Rating NPSHR – FEET 36 3 100 A 10 /32" 14' 12’ 43 TOTAL DYNAMIC HEAD (H) A B C D 38 8’ 17' B 917/32" 3 3 2 2 NOTE: Pump will pass a sphere to 1⁄8" diameter. 45 80 C 91/8" 103⁄32" 917⁄32 91⁄8 8¾ 43 EFF% D 83/4" 60 1 HP 3 HP 40 2 HP 20 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 25 50 75 U.S. GPM 100 CAPACITY (Q) METERS Model SSH / 4SH Size 11/2 x 21/2- 6 RPM 1750 Curve CN0489R01 FEET 15 Optional Impeller Impeller Code 4' NPSHR – FEET 54 3 A 6 /4" DIA. 6' 59 60 40 B 63/8" TOTAL DYNAMIC HEAD (H) Standard Dia. HP Rating 61 62 C 61/16" 62 8' 10 D 55/8" 30 61 60 EFF% E 55/16" 11 20 F 4 3 /16" G 4 /8" H 43/16" 5 3 10 1 6¾" 63⁄8 61⁄16 55⁄8 55⁄16 411⁄16 43⁄8 43⁄16 33⁄8 1 1 1 ¾ ¾ ½ ½ ½ ½ NOTE: Pump will pass a sphere to 3⁄16" diameter. 1 HP J 37/8" A B C D E F G H J ⁄4 HP ⁄2 HP NOTE: Not recommended for operation beyond printed H-Q curve. i 0 0 0 0 20 5 40 60 10 100 80 15 20 120 25 U.S. GPM 30 m3⁄ hr CAPACITY (Q) GOULDS PUMPS Commercial Water 10 Performance Curves – 60 Hz, 1750 RPM METERS Model SSH / 7SH Size 11/2 x 21/2-8 RPM 1750 Curve CN0492R00 FEET Optional Impeller Impeller Code Standard Dia. HP Rating 6' NPSHR – FEET A 81/4" DIA. 38 20 48 TOTAL DYNAMIC HEAD (H) 60 B 713/16" 53 54 55 8' 56 57 10' C 7" 15 13' 3 D 6 /4" 57 E 67/16" 40 F 61/8" A 8¼" 2 B C D 713⁄16 7 6¾ 2 1½ 1½ E F 67⁄16 61⁄8 1 1 NOTE: Pump will pass a sphere to 3⁄16" diameter. 56 55 EFF% 2 HP 10 11⁄2 HP 20 1 HP 5 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 20 0 60 40 10 5 80 15 120 100 20 25 U.S. GPM 30 m3⁄ hr CAPACITY (Q) METERS Model SSH / 5SH Size 2 x 21/2-6 RPM 1750 Curve CN0495R00 FEET A 67/8" DIA. 48 Optional Impeller Impeller Code 4' NPSHR – FEET 58 7 40 B 6 /16" 63 7' TOTAL DYNAMIC HEAD (H) 65 66 30 9' 67 C 513/16" 10 D 51/2" 67 12' 66 E 51/8" 65 EFF% F 413/16" 20 5 Standard Dia. HP Rating 2 HP G 47/16" H 41/4" A B C D E F G 67⁄8" 67⁄16 513⁄16 5½ 51⁄8 413⁄16 47⁄16 2 2 1½ 1½ 1 1 ¾ H 4¼ ¾ NOTE: Pump will pass a sphere to 5⁄32" diameter. 11⁄2 HP 1 HP 10 3 ⁄4 HP NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 0 40 10 120 80 20 160 30 200 40 U.S. GPM 50 m3⁄ hr CAPACITY (Q) GOULDS PUMPS Commercial Water 11 Performance Curves – 60 Hz, 1750 RPM METERS Model SSH / 8SH Size 2 x 21/2-8 RPM 1750 Curve CN0498R01 FEET A 81/4" DIA. 20 48 58 B 73/4" Optional Impeller 5' NPSHR – FEET 67 63 60 C 71/2" Impeller Code 7' 69 D 73/16" TOTAL DYNAMIC HEAD (H) 15 9' 7 50 E 6 /8" 11' 69 F 63/16" 67 EFF% 40 Standard Dia. HP Rating A 8¼" 3 B 7¾ 3 C D E 7½ 73⁄16 67⁄8 2 2 1½ F 63⁄16 1½ NOTE: Pump will pass a sphere to 5⁄32" diameter. 3 HP 10 30 2 HP 11/2 HP 20 5 10 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 0 120 80 40 20 10 160 200 30 40 U.S. GPM 50 m3⁄ hr CAPACITY (Q) METERS Model SSH / 6SH Size 21/2 x 3-6 RPM 1750 Curve CN0502R00 FEET Optional Impeller Impeller Code Standard Dia. HP Rating 20 4' NPSHR – FEET 60 A B C D E F G 57 5' A 75/16" DIA. 62 15 50 B 71/8" 67 67 TOTAL DYNAMIC HEAD (H) 15 C 6 /16" 7' 65 D 611/16" 9' 40 E 6 /8" 3 63 11' 15' F 61/16" 62 10 30 G 55/8" 75⁄16" 71⁄8 615⁄16 611⁄16 63⁄8 61⁄16 55⁄8 3 3 3 3 2 2 1½ NOTE: Pump will pass a sphere to 5⁄16" diameter. 19' 60 57 EFF% 20 5 3 HP 10 2 HP 11/2 HP NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 0 100 300 200 25 50 U.S. GPM 400 75 m3⁄ hr CAPACITY (Q) GOULDS PUMPS Commercial Water 12 Performance Curves – 50 Hz, 2900 RPM FEET Optional Impeller Model SSH / 9SH Size 1 x 2-6 RPM 2900 Curve CN0621R00 120 Impeller Code 50 40 A 65/8" DIA. 4' B 67/16" 100 55 5' NPSHR – FEET 56 TOTAL DYNAMIC HEAD (H) Standard Dia. HP Rating 7' C 511/16" 55 EFF% A 65⁄8" B C 67⁄16 511⁄16 D 53⁄8 3 3 2 2 NOTE: Pump will pass a sphere to 1⁄8" diameter. 80 D 53/8" 60 3 HP 40 1 2 HP /2 HP 20 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 20 40 80 60 100 U.S. GPM 120 CAPACITY (Q) FEET Optional Impeller Model SSH / 10SH Size 1 x 2-8 RPM 2900 Curve CN0615R00 Impeller Code 250 5' NPSHR – FEET 200 TOTAL DYNAMIC HEAD (H) 42 7' A 83/8" DIA. 47 B 81/16" 150 9’ 12’ C 75/8" Standard Dia. HP Rating A 83⁄8" 5 B C D E 81⁄16 75⁄8 71⁄8 71⁄8 5 5 5 3 NOTE: Pump will pass a sphere to 1⁄8" diameter. 49 EFF% D 75/16" E 71/8" 100 5 HP 3 HP 50 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 25 50 75 100 125 U.S. GPM 150 CAPACITY (Q) GOULDS PUMPS Commercial Water 13 Performance Curves – 50 Hz, 2900 RPM Optional Impeller Model SSH / 11SH Size 1 x 2-10 RPM 2900 Curve CN0618R00 FEET Impeller Code 300 30 NPSHR – FEET A 103/32" DIA. 8’ 18' 38 14’ 250 TOTAL DYNAMIC HEAD (H) Standard Dia. HP Rating B 917/32" 20' 43 45 C 91/8" A B C 103⁄32" 917⁄32 91⁄8 15 10 10 D 8¾ 7½ NOTE: Pump will pass a sphere to 1⁄8" diameter. 43 EFF% 200 D 83/4" 150 10 HP 100 71/2 HP NOTE: Not recommended for operation beyond printed H-Q curve. 50 0 25 50 100 75 125 150 U.S. GPM 175 CAPACITY (Q) METERS Model SSH / 4SH Size 11/2 x 21/2-6 RPM 2900 Curve CN0490R01 FEET Optional Impeller Impeller Code 4' NPSHR – FEET 40 120 55 A 63/4" DIA. 6' 60 61 B 63/8" TOTAL DYNAMIC HEAD (H) 30 Standard Dia. HP Rating 62 64 100 C 61/16" 64 8' D 55/8" 62 80 61 EFF% 5 E 5 /16" 20 60 F 411/16" G 43/8" H 43/16" 6¾" 63⁄8 5 5 C D E F G H J 61⁄16 55⁄8 55⁄16 411⁄16 43⁄8 43⁄16 33⁄8 5 3 3 2 2 1½ 1 NOTE: Pump will pass a sphere to 3⁄16" diameter. 5 HP 40 J 37/8" A B 3 HP 10 2 HP 20 1 HP NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 0 40 10 80 120 20 160 30 200 40 U.S. GPM 50 m3⁄ hr CAPACITY (Q) GOULDS PUMPS Commercial Water 14 Performance Curves – 50 Hz, 2900 RPM METERS 60 Model SSH / 7SH Size 11/2 x 21/2- 8 RPM 2900 Curve CN0493R00 FEET 200 Optional Impeller Impeller Code 6' NPSHR – FEET A 81/4" DIA. 39 49 B 713/16" TOTAL DYNAMIC HEAD (H) 50 54 8' 55 160 56 57 58 13' C 7" 40 Standard Dia. HP Rating 17' D 63/4" 120 E 67/16" 58 57 F 61/8" 30 A 8¼" 10 B C D 713⁄16 7 6¾ 7½ 7½ E F 67⁄16 61⁄8 5 5 7½ NOTE: Pump will pass a sphere to 3⁄16" diameter. 56 EFF% 10 HP 71/2 HP 80 20 5 HP 40 10 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 40 0 80 10 120 160 20 200 30 U.S. GPM 50 40 m3⁄ hr CAPACITY (Q) METERS Optional Impeller, Model SSH / 5SH Size 2 x 21/2-6 RPM 2900 Curve CN0496R01 FEET 40 49 A 67/8" DIA. Impeller Code 5' NPSHR – FEET 59 120 64 7' B 67/16" TOTAL DYNAMIC HEAD (H) 66 67 30 100 68 10' 13 C 5 /16" 80 68 14' 67 D 51/2" 66 EFF% E 51/8" 20 Standard Dia. HP Rating 10 HP F 413/16" 60 7 G 4 /16" A B C D E F G H 67⁄8" 67⁄16 513⁄16 5½ 51⁄8 413⁄16 47⁄16 4¼ 10 7½ 7½ 5 5 3 3 3 NOTE: Pump will pass a sphere to 5⁄32" diameter. 71/2 HP H 41/4" 40 5 HP 10 3 HP 20 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 0 40 10 80 20 120 160 30 240 200 40 50 280 60 320 70 360 U.S. GPM 80 m3⁄ hr CAPACITY (Q) GOULDS PUMPS Commercial Water 15 Performance Curves – 50 Hz, 2900 RPM METERS Model SSH / 8SH Size 2 x 21/2-8 RPM 2900 Curve CN0499R01 FEET Impeller Code 6' NPSHR – FEET A 81/4" DIA. 49 B 73/4" 50 Optional Impeller 59 7' 64 1 160 C 7 /2" D 73/16" 70 9' E 67/8" 13' 71 40 TOTAL DYNAMIC HEAD (H) A B C D E F 68 70 120 F 63/16" 16' 68 30 64 EFF% Standard Dia. HP Rating 8¼" 7¾ 7½ 73⁄16 67⁄8 63⁄16 15 15 10 10 7½ 7½ NOTE: Pump will pass a sphere to 5⁄32" diameter. 15 HP 80 20 10 HP 40 71/2 HP 10 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 80 40 0 120 20 10 200 160 240 40 30 280 60 50 320 360 U.S. GPM 80 70 m3⁄ hr CAPACITY (Q) METERS FEET Model SSH / 6SH Size 21/2 x 3-6 RPM 2900 Curve CN0501R00 50 58 7' A 75/16" DIA. 64 150 TOTAL DYNAMIC HEAD (H) Impeller Code B 71/8" C 615/16" 69 69 8' 67 125 D 611/16" 11' E 63/8" 30 100 Standard Dia. HP Rating 6' NPSHR – FEET 175 40 Optional Impeller 65 13' 17' F 61/16" 64 A B C 75⁄16" 71⁄8 615⁄16 15 15 15 D E F 611⁄16 63⁄8 61⁄16 10 10 7½ G 55⁄8 7½ NOTE: Pump will pass a sphere to 5⁄16" diameter. 21' 5 G 5 /8" 62 75 58 EFF% 20 50 15 HP 10 10 HP 25 71/2 HP NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 0 100 25 200 400 300 50 75 600 U.S. GPM 500 100 125 m3⁄ hr CAPACITY (Q) GOULDS PUMPS Commercial Water 16 Performance Curves – 60 Hz, 3500 RPM METERS Model SSH – 24SH / Size 11/2 x 21/2-10 RPM 3500 Curve CN0503R00 FEET Optional Impeller Impeller Code 450 130 120 TOTAL DYNAMIC HEAD (H) 110 50% EFF 55 1 B 9 /2" 350 8' 57 10' 59 C 93/16" D 87/8" 90 300 E 89/16" 80 6' NPSHR – FEET A 97/8" DIA. 400 100 60 12' 59 55 F 81/4" 250 70 60 Standard Dia. HP Rating 30 200 25 50 20 150 A B C D 97⁄8" 9½ 93⁄16 87⁄8 E F 89⁄16 8¼ 30 30 25 25 20 20 NOTE: Pump will pass a sphere to 5⁄16" diameter. HP HP HP 40 30 100 20 10 50 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 50 100 0 150 200 20 300 U.S. GPM 250 40 m3⁄hr 60 CAPACITY (Q) METERS Model SSH – 25SH / Size 2 x 21/2-10 RPM 3500 Curve CN0506R00 FEET 450 130 120 110 TOTAL DYNAMIC HEAD (H) 60 62 9' 63 350 C 91/8" 64 20' 64 80 E 83/16" F 715/16" 250 G 711/16" A B C D E F G 11' D 813/16" 300 63 50 40 200 30 50 150 25 40 30 Standard Dia. HP Rating 55% EFF B 91/2" 90 60 Impeller Code 7' NPSHR – FEET A 97/8" DIA. 400 100 70 Optional Impeller HP HP 97⁄8" 9½ 91⁄8 813⁄16 83⁄16 715⁄16 711⁄16 50 40 40 30 30 25 25 NOTE: Pump will pass a sphere to ½" diameter. HP HP 100 20 50 10 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 50 100 20 150 200 250 40 300 60 350 80 400 450 100 500 U.S. GPM m3⁄hr CAPACITY (Q) GOULDS PUMPS Commercial Water 17 Performance Curves – 60 Hz, 3500 RPM METERS 100 90 FEET TOTAL DYNAMIC HEAD (H) Optional Impeller Impeller Code (PIES) 7' NPSHR – FEET 8' 40% EFF 50 350 60 A 91/16" DIA. 65 3 325 B 8 /4" 300 275 80 Model SSH – 22SH / Size 21/2 x 3-8 RPM 3500 Curve CN0509R00 10' 12' 15' 68 C 81/2" 20' 70 D 81/4" 25' 68 30' 65 7 250 E 7 /8" 70 225 F 7 /2" 60 200 G 7 /8" 60 71 1 1 11 175 H 6 /16" 60 J 61/2" 50 15 125 HP 8¾ 50 C 8½ 50 D 8¼ 40 E 77⁄8 40 F 7½ 30 G 71⁄8 25 H 11 6 ⁄16 20 J 6½ 20 NOTE: Pump will pass a sphere to 19⁄32" diameter. HP 75 25 0 100 0 20 200 300 400 60 40 30 HP 20 HP NOTE: Not recommended for operation beyond printed H-Q curve. 500 80 100 HP 100 50 60 B HP 20 91⁄16" 40 30 A 50 150 40 Standard Dia. HP Rating HP 600 120 800 700 160 140 180 U.S. GPM m3⁄hr CAPACITY (Q) METERS Model SSH – 27SH / Size 21/2 x 3-10 RPM 3500 Curve CN0512R00 FEET Optional Impeller Impeller Code Standard Dia. HP Rating 600 175 7' NPSHR – FEET 550 45% EFF 55 TOTAL DYNAMIC HEAD (H) 150 500 8' 10' 60 12' 65 3 A 10 /8" DIA. 125 15' 69 450 B 915/16" 20' 30' 70 9 400 C 9 /16" 69 D 91/4" 10 350 E 83/4" 100 300 75 40 250 25 100 915⁄16 75 9 75 C 9 ⁄16 D 9¼ 60 E 8¾ 50 NOTE: Pump will pass a sphere to 19⁄32" diameter. P HP 60 50 150 HP HP 100 50 0 103⁄8" B 75 65 HP 200 50 0H A 0 NOTE: Not recommended for operation beyond printed H-Q curve. 0 100 0 20 200 40 300 60 400 80 500 100 120 600 140 700 800 U.S. GPM 160 180 m3⁄hr CAPACITY (Q) GOULDS PUMPS Commercial Water 18 Performance Curves – 60 Hz, 3500 RPM METERS FEET 10' 50% EFF 350 100 TOTAL DYNAMIC HEAD (H) 90 NOTE: Not recommended for operation beyond printed H-Q curve. Model SSH – 23SH / Size 3 x 4-8 RPM 3500 Curve CN0515R00 70 325 Impeller Standard Code Dia. HP Rating 12' NPSHR – FEET 60 14' A 91/16" DIA. B 811/16" 17' 75 77 300 C 8 /16" 7 20' 78 275 D 81/16" 78 25' 77 30' 80 250 E 711/16" 70 225 F 7 /2" 60 200 G 71/8" 75 H 67/8" 175 J 61/2" 60 150 40 30 20 10 0 75 1 50 70 50 125 K 6" 100 40 L 51⁄2" 75 15 50 0 200 0 40 400 80 600 120 Optional Impeller HP HP 91⁄16" 75 B 811⁄16 75 C 87⁄16 60 D 81⁄16 50 E 711⁄16 50 F 7½ 40 G 71⁄8 40 H 67⁄8 30 25 J 6½ K 6 20 L 5½ 15 NOTE: Pump will pass a sphere to ¾" diameter. HP HP 3 25 0 HP H 20 HP P HP 800 160 HP A 1000 200 1400 1200 240 320 280 1600 360 U.S. GPM m3⁄hr CAPACITY (Q) METERS Model SSH – 28SH / Size 3 x 4-10 RPM 3500 Curve CN0518R00 FEET Optional Impeller Impeller Code Standard Dia. HP Rating 600 175 550 150 NPSHR – FEET 8' 10' 45% EFF 55 65 500 TOTAL DYNAMIC HEAD (H) 450 125 C D E 12' 70 C 913/16" DIA. F 14' 73 17' 75 400 D 97/16" 25' 76 350 E 91/16" 100 73 250 60 10 HP 200 50 25 75 0H P HP 150 100 50 0 30' F 811/16" 300 75 75 100 100 75 75 NOTE: Pump will pass a sphere to ¾" diameter. 20' 76 913⁄16" 97⁄16 91⁄16 811⁄16 0 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 200 40 400 80 600 120 800 160 1000 200 240 1200 280 1400 320 1600 360 U.S. GPM m3⁄hr CAPACITY (Q) GOULDS PUMPS Commercial Water 19 Performance Curves – 60 Hz, 1750 RPM METERS Model SSH – 24SH / Size 11/2 x 21/2-10 RPM 1750 Curve CN0505R00 FEET Optional Impeller Impeller Code 110 A 9 /8" DIA. 30 100 45% EFF 50 B 91/2" 90 52 4' 54 C 93/16" TOTAL DYNAMIC HEAD (H) 25 56 7 80 D 8 /8" 54 E 89/16" 20 5' 52 70 F 81/4" 50 60 15 Standard Dia. HP Rating 3' NPSHR – FEET 7 50 3H A 97⁄8" 5 B 9½ 5 C 93⁄16 3 D 87⁄8 3 E 89⁄16 3 F 8¼ 2 NOTE: Pump will pass a sphere to 5⁄16" diameter. P 40 10 2H P 30 20 5 10 0 NOTE: Not recommended for operation beyond printed H-Q curve. 10 0 20 30 40 5 0 60 50 70 80 90 15 10 110 100 120 150 U.S. GPM 140 30 25 20 130 m3⁄hr CAPACITY (Q) METERS Optional Impeller Model SSH – 25SH / Size 2 x 21/2-10 RPM 1750 Curve CN0508R00 FEET Impeller Code 110 4' NPSHR – FEET 50% EFF 7 A 9 /8" DIA. 30 100 55 B 91/2" 57 A 97⁄8" 7½ B 9½ 5 C 91⁄8 5 D 813⁄16 5 F 7 /16" E 83⁄16 3 60 G 711/16" F 715⁄16 3 G 11 3 58 90 C 9 /8" TOTAL DYNAMIC HEAD (H) 20 15 5' 59 1 25 13 80 D 8 /16" 59 8' 58 70 E 83/16" 7.5 HP 15 5H P 50 7 ⁄16 NOTE: Pump will pass a sphere to ½" diameter. 40 10 Standard Dia. HP Rating 30 3H P 20 5 10 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 20 0 5 40 60 10 100 80 15 20 120 25 140 30 160 35 180 40 200 220 45 50 240 55 U.S. GPM m3⁄hr CAPACITY (Q) GOULDS PUMPS Commercial Water 20 Performance Curves – 60 Hz, 1725 RPM METERS Model SSH – 22SH / Size 21/2 x 3-8 RPM 1750 Curve CN0511R00 FEET Optional Impeller Impeller Standard Code Dia. HP Rating 120 35 110 30 100 TOTAL DYNAMIC HEAD (H) 90 25 40% EFF 5' 50 NPSHR – FEET 6' 55 80 A 9 /16" DIA. 1 60 8' 62 C 8 /2" 70 64 D 81/4" 10' 62 60 E 7 /8" 7 60 15' 55 15 50 91⁄16" 7½ C 8½ 7½ D 8¼ 5 E 77⁄8 5 G 71⁄8 3 H 611⁄16 3 NOTE: Pump will pass a sphere to 19⁄32" diameter. 1 20 A 50 G 71/8" 40 H 611/16" 10 5 2 30 71 /2 20 5 10 0 HP 3 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 50 10 0 100 150 30 20 200 250 40 50 70 HP HP 350 300 60 HP 450 U.S. GPM 400 100 90 80 m3⁄hr CAPACITY (Q) METERS Model SSH – 27SH / Size 21/2 x 3-10 RPM 1750 Curve CN0514R00 FEET 3 55 Impeller Code NPSHR – FEET 50% EFF 120 Optional Impeller 60 5' 63 A 103/8" DIA. 66 110 68 7' B 915/16" 3 68 C 99/16" 15' 66 D 91/4" 20' 63 80 E 83/4" 60 15 15 915⁄16 10 C 9 9 ⁄16 10 D 9¼ 7½ E 8¾ 7½ HP 55 103⁄8" B NOTE: Pump will pass a sphere to 19⁄32" diameter. 70 2 A 60 5 15 HP TOTAL DYNAMIC HEAD (H) 2 10' 100 90 Standard Dia. HP Rating 50 10 HP / 1 2 7 40 30 P 5 H 10 20 10 0 0 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 50 10 100 20 150 30 200 40 250 50 300 60 70 350 80 400 90 450 U.S. GPM 100 m3⁄hr CAPACITY (Q) GOULDS PUMPS Commercial Water 21 Performance Curves – 60 Hz, 1725 RPM METERS NOTE: Not recommended for operation beyond printed H-Q curve. Model SSH – 23SH / Size 3 x 4-8 RPM 1750 Curve CN0517R00 FEET Optional Impeller Impeller Code Standard Dia. HP Rating 120 35 30 110 A 91⁄16" 10 100 C 87⁄16 7½ D 81⁄16 7½ F 7½ 5 G 71⁄8 5 45% EFF TOTAL DYNAMIC HEAD (H) 90 25 55 1 80 A 9 /16" DIA. 65 5' NPSHR – FEET 68 6' 71 10' 74 1 D 8 /16" 15' 60 15 73 5 68 G 71/8" 65 40 10 71 F 71/2" 50 J 61/2" 55 30 3 20 10 71 /2 H HP 5H 10 0 J 6½ 3 NOTE: Pump will pass a sphere to ½" diameter. 8' 73 70 C 87/16" 20 0 0 100 20 0 200 40 300 400 80 60 500 100 600 120 HP P P 140 900 U.S. GPM 800 700 160 200 180 m3⁄hr CAPACITY (Q) METERS FEET 40 130 Model SSH – 28SH / Size 3 x 4-10 RPM 1750 Curve CN0520R00 45% EFF 55 65 120 A 105/8" DIA. Optional Impeller Impeller Code 7' NPSHR – FEET 70 35 TOTAL DYNAMIC HEAD (H) 30 8' 73 110 B 101/4" 10' 100 C 913/16" 74 25 20' 70 60 H P 20 50 15 40 30 20 20 B 10¼ 15 C 913⁄16 15 D 97⁄16 15 65 10 20 10 105⁄8" 30' 80 70 15 A NOTE: Pump will pass a sphere to ¾" diameter. 15' 73 7 90 D 9 /16" Standard Dia. HP Rating H H P P NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 100 20 200 40 300 60 400 80 500 100 120 600 140 700 160 800 180 900 U.S. GPM 200 m3⁄hr CAPACITY (Q) GOULDS PUMPS Commercial Water 22 Performance Curves – 50 Hz, 2900 RPM METERS 90 Model SSH – 24SH / Size 11/2 x 21/2-10 RPM 2900 Curve CN0504R00 FEET Optional Impeller Impeller Code 300 3' NPSHR – FEET 7 A 9 /8" DIA. 48% EFF 80 6' 53 250 B 91/2" 55 8' 57 C 93/16" 70 58 TOTAL DYNAMIC HEAD (H) D 87/8" 60 10' 57 9 200 E 8 /16" F 81/4" 55 53 20 HP 50 15 30 100 10 A 97⁄8" 20 B 9½ 15 C D 93⁄16 87⁄8 15 15 E 89⁄16 10 F 8¼ 10 NOTE: Pump will pass a sphere to ½" diameter. 150 40 Standard Dia. HP Rating HP HP 20 50 10 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 20 0 40 60 100 80 120 20 10 140 160 180 200 220 40 30 240 U.S. GPM m3⁄hr 50 CAPACITY (Q) METERS 90 Model SSH – 25SH / Size 2 x 21/2-10 RPM 2900 Curve CN0507R00 FEET Optional Impeller Impeller Code 300 6' NPSHR – FEET 53% EFF A 97/8" DIA. 80 250 58 B 91/2" 60 8' 61 62 1 C 9 /8" TOTAL DYNAMIC HEAD (H) 70 10' D 813/16" 62 60 200 E 83/16" F 715/16" G 711/16" 50 30 100 30 25 B 9½ 91⁄8 20 61 D 813⁄16 20 E 83⁄16 15 F 715⁄16 15 G 11 15 20 15 97⁄8" C 25 40 A 17' 30 150 Standard Dia. HP Rating HP HP 7 ⁄16 NOTE: Pump will pass a sphere to 5⁄16" diameter. HP HP 20 50 10 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 40 80 20 120 160 200 40 240 280 60 320 360 80 400 U.S. GPM m3⁄hr CAPACITY (Q) GOULDS PUMPS Commercial Water 23 Performance Curves – 50 Hz, 2900 RPM METERS Model SSH – 22SH / Size 21/2 x 3-8 RPM 2900 Curve CN0510R00 FEET 250 40% EFF 70 50 A 91/16" DIA. Optional Impeller 6' NPSHR – FEET 7' 60 Impeller Standard Code Dia. HP Rating 8' 10' 225 B 83/4" 65 C 81/2" 60 TOTAL DYNAMIC HEAD (H) 15' 200 67 D 81/4" 50 12' 18' 65 68 F 71/2" 150 40 20' 60 175 E 77/8" 40 G 71/8" 125 H 611/16" HP J 61/2" 30 100 50 10 25 HP 20 75 20 50 15 10 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 100 0 20 200 300 60 40 400 80 91⁄16" 40 B 8¾ 30 C 8½ 30 D 8¼ 25 E 77⁄8 20 F 7½ 20 G 71⁄8 15 H 11 6 ⁄16 15 J 6½ 15 NOTE: Pump will pass a sphere to 19⁄32" diameter. HP HP HP HP 500 100 30 A 600 120 140 U.S. GPM 700 m3⁄hr CAPACITY (Q) METERS Model SSH – 27SH / Size 21/2 x 3-10 RPM 2900 Curve CN0513R00 FEET Optional Impeller Impeller Standard Code Dia. HP Rating 400 NPSHR – FEET 45% EFF 350 6' 55 100 8' 60 10' 65 A 103/8" DIA. 12' 68 15' TOTAL DYNAMIC HEAD (H) 300 B 915/16" 69 C 99/16" 75 68 20' 65 250 D 91/4" E 83/4" 50 200 25 50 HP 40 150 30 100 A 103⁄8" 50 15 40 B 9 ⁄16 C 9 9⁄16 40 D 9¼ 30 E 8¾ 30 NOTE: Pump will pass a sphere to 19⁄32" diameter. HP HP HP 25 50 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 0 100 20 200 40 300 60 400 80 500 100 600 120 140 U.S. GPM 700 m3⁄hr CAPACITY (Q) GOULDS PUMPS Commercial Water 24 Performance Curves – 50 Hz, 2900 RPM METERS Model SSH – 23SH / Size 3 x 4-8 RPM 2900 Curve CN0516R00 FEET 250 50% EFF 70 10' NPSHR – FEET 225 12' 72 70 B 811/16" 60 C 87/16" 200 Impeller Standard Code Dia. HP Rating 9' 60 A 91/16" DIA. Optional Impeller 15' 74 76 TOTAL DYNAMIC HEAD (H) D 81/16" 50 20' 76 74 175 E 711/16" 72 F 71/2" 150 50 G 71/8" 40 HP 40 J 61/2" 70 30 91⁄16" B 811⁄16 40 C 87⁄16 40 D 81⁄16 30 E 711⁄16 30 50 F 7½ 25 G 71⁄8 20 H 67⁄8 20 J 6½ 15 NOTE: Pump will pass a sphere to ½" diameter. 7 125 H 6 /8" A HP 100 30 20 75 25 20 50 15 10 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 200 0 400 600 80 40 120 HP HP HP HP 800 160 1000 200 1200 240 280 U.S. GPM 1400 m3⁄hr CAPACITY (Q) METERS Model SSH – 28SH / Size 3 x 4-10 RPM 2900 Curve CN0519R00 FEET Optional Impeller Impeller Standard Code Dia. HP Rating 400 350 NPSHR – FEET (PIES) 100 50% EFF 8' 9' 60 300 65 TOTAL DYNAMIC HEAD (H) C 913/16" DIA. 75 10' 70 12' 14' 73 17' 75 D 97/16" 250 75 E 91/16" C 913⁄16" 60 D 97⁄16 50 E 1 9 ⁄16 50 F 811⁄16 40 NOTE: Pump will pass a sphere to ¾" diameter. 20' 73 F 811/16" 200 30 50 60 HP 50 150 40 HP HP HP 100 25 50 NOTE: Not recommended for operation beyond printed H-Q curve. 0 0 0 0 200 40 400 80 600 120 800 160 1000 200 1200 240 280 U.S. GPM 1400 m3⁄hr CAPACITY (Q) GOULDS PUMPS Commercial Water 25 SSH Close Coupled – Materials of Construction 178 101 100 108 103 SSH Frame Mounted – Materials of Construction 101 100 370 513 370 228 383 108 184 412A 513 134 184 370C 333A 412A 383 199 422 408 412F 126 Item No., Description 371 103 199 422 408 178 412F Item No., Description Materials 126 370B 123 168 112 100 Casing 100 Casing 101 Impeller 101 Impeller 103 Wear ring 103 Wear ring 184 Seal housing 126 Shaft sleeve 316 SS Carbon steel 184 Seal housing 126 Shaft sleeve 422 178 199 316L SS 316 SS Impeller stud Steel Impeller key Carbon steel Impeller washer Casing bolt with nut (casing to adapter) 370 Hex head cap screw (adapter to motor) 371 412A O-ring, Impeller 412F O-ring, shaft sleeve 513 O-ring 408 383 178 Impeller key 422 Impeller Stud 199 Impeller washer 316 SS 316L SS 370 Casing bolt with nut 316L SS 408 Drain plug – 3⁄8 NPT 513 O-ring Viton 383 Mechanical seal See seal chart 108 Adapter 228 Bearing frame Cast iron ASTM A48CL20 134 Bearing cover 122 Pump shaft 168 Ball bearing (inboard) 112 Ball bearing (outboard) 382 Retaining ring Adapter Steel SAE 1200 series Viton Drain plug – 3⁄8 NPT 316L SS Mechanical seal See seal chart 122 316L SS 316 SS Cast iron ASTM A48 CL20 108 382 Materials Carbon steel Hex head cap screw (adapter to bearing frame) Steel 370B Hex head cap screw (bearing frame to cover) Mechanical Seal 370C John Crane Type 21 Mechanical Seal Part No. Item 383 Options 180-210 Frames 250-360 Frames 10K19 10K20 10K27 10K45 Rotary Stationary Elastomers 10K65 Intended Duty 333A Lip seal BUNA-N 193 *Grease fitting Steel 123 V-ring deflector BUNA-N * M-Group only Carbon Silicon Carbide EPR Sil-Carb. Hot Water 316 SS Mild Abrasive Viton 10K64 Metal Parts Severe Duty GOULDS PUMPS Commercial Water 26 SSH – Engineering Data S-Group Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End CP DISCHARGE AB MAX. 3¾ CREF Z Y SPACER COUPLING PRIME PLUG 3½ 1.125 Ø 1.124 X COUPLING GUARD SUCTION SINGLE PHASE ONLY DC DD MAX. HD KEYWAY 1⁄8 x ¼ HE HL 3 ⁄8" – 19 BSP HP HF HB HA Dimensions and Weights – Determined by Pump Dimension “HL” Determined by Pump and Bedplate Motor Frame Size Suction* Discharge* CP DC Max. DD Pump (4) HOLES 5 ⁄8 DIA. HG DRAIN PLUG HE P MAX. 9SH 1 X 2–6 163⁄4 10SH 1 X 2–8 2 1 11SH 1 X 2–10 179⁄16 4SH 1½ X 2½–6 169⁄16 1½ 7SH 1½ X 2½–8 2½ 5SH 2 X 2½–6 2 175⁄16 8SH 2 X 2½–8 6SH 2½ X 3–6 3 2½ * For use with ANSI Class 150 mating flanges. 5 55⁄8 67⁄8 5 55⁄8 5 6 4¾ 53⁄8 65⁄8 4¾ 53⁄8 4¾ X Y Z 63⁄8 1 3 ⁄8 7 71⁄8 3 ⁄8 7 8 ⁄8 4 63⁄8 3¼ 71⁄8 4 35⁄8 5¾ 715⁄16 Wt. (lbs.) 143/ 183/ 145 184 56 91⁄8 64 86 10 57 9¼ 66 57 10 68 59 213/ 215 254/ 284/ 256 286 75⁄8 37⁄8 8½ 7¾ 4¾ 4 8½ 4¾ NOTES: 1. All pumps shipped in vertical discharge position. May be rotated in 90° increments. Tighten 3⁄8 – 16 casing bolts to 12 ft./lbs. torque. 2. Dimensions in inches. 3. Motor dimensions may vary with motor manufacturer. 4. Not to be used for construction purposes. Available Motor and Bedplate Dimensions and Weights Motor Frame HP @ 3500 RPM Single Phase ODP TEFC HP @ 1750 RPM Three Phase ODP TEFC 143T Bedplate Data Single Phase Three Phase ODP TEFC ODP TEFC 1 1 1 1 145T 2 2 2–3 2 1½ 1½ 1½ – 2 1½ – 2 182T 3 3 5 3 2 2 3 3 184T 5 5 7½ 5 3 or 5 3 5 3 213T 10 7½ 215T 15 10 254T 20 15 256T 25 20 284TS 30 25 286TS 40 30 AB Max. 5¼ 57⁄8 73⁄8 101⁄8 125⁄8 C REF 133⁄8 14¼ 165⁄8 181⁄8 18 191⁄8 215⁄8 233⁄8 247⁄8 265⁄8 P Wt. Max. Max. HA HB HD** HE HF HG HP* 65⁄8 77⁄8 95⁄8 13 15 Wt. (lbs.) 45 53 74 1¾ 10 28 8 3¾ 24 2¾ ¾ 48 136 266 264 392 432 — ¾ 95 116 Motor Bearing Shim Frame Shim 12 31 8¼ 4¼ 29 3 13 42 10¼ 5¼ 38½ 4 15 44 10½ 5¾ 40½ 3½ 1 65 — — 110 — 1 124 – 1¾ 1¾ Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs. * “HP” Dimensions at motor end only. ** “HD” Dimension for 254T/256T motor frame on 1 x 2-10 only is 11"; A ¾" motor shim and a 1¾" bearing frame shim are required. GOULDS PUMPS Commercial Water 27 SSH-F – Engineering Data M-Group Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End C REF. CP DISCHARGE ABMAX. 3 3⁄4 41 5 ⁄ 1 6 Y SPACER COUPLING 3 7⁄ 8 PRIME PLUG COUPLING GUARD SINGLE PHASE ONLY 1.625 1.624 SUCTION PMAX. DC MAX. DD 4 HOLES KEYWAY 5⁄8 3/16 X 3/8 HD HG DRAIN PLUG HE HE HA HB NOTE: 1. Pumps will be shipped with top vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position and tighten 3⁄8 – 16 bolts to 12 ft./lbs. 2. ALL dimensions in inches. 3. Not for construction purposes. Dimensions and Weights – Determined by Pump, Pump Size, Pump 24SH 25SH 22SH 27SH 23SH 28SH Suction* Discharge* 1½ x 2½-10 2 x 2½-10 2½ x 3-8 2½ x 3-10 3 x 4-8 3 x 4-10 1½ 2 2½ 3 CP 23 2½ 4 3 24 13 ⁄ 4 HF L 3/8” 3GAS ⁄8" –THREAD 19 BSP UNI ISO 228/1 DC Max. DD 67⁄8 65⁄8 L 1 61⁄8 57⁄8 67⁄8 65⁄8 10 ⁄8 X Y 815⁄16 73⁄8 125 125 125 134 136 148 4 915⁄16 1 75⁄8 Wt. (lbs.) 11 ⁄8 111⁄8 5 * For use with ANSI class 150 mating flanges. Available Motor and Bedplate Dimensions and Weights Motor Frame HP @ 3500 RPM Three Phase ODP TEFC 184T HP @ 1750 RPM – T-Frame Only Single Phase Three Phase ODP TEFC ODP TEFC 3 or 5 3 5 5 7½ 7½ 10 10 213T 215T 15 254T 20 15 15 15 256T 25 20 20 20 284TS/T 30 25 25 25 286TS/T 40 30 324TS/T 50 40 326TS/T 60 50 364TS/T 75 60 365TS/T 100 75 405TS/T 100 AB Max. 57⁄8 73⁄8 91⁄2 125⁄8 141⁄8 151⁄8 18 C 181⁄8 18 191⁄8 215⁄8 233⁄8 247⁄8 265⁄8 283⁄4 30¼ 315⁄8 325⁄8 367⁄8 P Max. 77⁄8 95⁄8 13 15 173⁄8 187⁄8 205⁄8 Bedplate Data Wt. Max. HA HB HD HE HF HG Wt. (lbs.) 13 42 101⁄4 51⁄4 38½ 4 111 15 44 10½ 5¾ 40½ 3½ 124 18 48 7¼ 44½ 4 183 7¼ 52½ 4 214 95 116 136 266 264 392 422 592 634 834 12 13 1000 1060 22 56 14 Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs. GOULDS PUMPS Commercial Water 28 S-Group SSH Close Coupled – Dimensions and Weights (All dimensions in inches and weights in lbs. Do not use for construction purposes.) DISCHARGE AB MAX. Y CREF Z PRIME PLUG X SUCTION P MAX. G DRAIN PLUG E E DC DD MAX. D L 3 ⁄8" – 19 BSP A 150 lb. Flange DC Max. Pump 2 1 1½ 2½ 2 3 DD X 4¾ 53⁄8 65⁄8 4¾ 53⁄8 4¾ 5¾ 4¾ 63⁄8 71⁄8 87⁄8 63⁄8 71⁄8 71⁄8 Y Wt. (lbs.) Z 143/145 182/184 213/215 254/256 5 55⁄8 67⁄8 5 55⁄8 5 6 2½ 1 3 ⁄8 37⁄8 4 3¼ 4 35⁄8 93⁄8 10½ 11½ — 10¾ 9¾ 113⁄8 103⁄8 123⁄8 113⁄8 125⁄8 — 10½ 111⁄8 121⁄8 123⁄8 15 7 ⁄16 F H-(4) HOLES B DIM. “L” (Motor Frame Size) Suct.* Disch.* 9SH 1x2–6 10SH 1 x 2 – 8 11SH 1 x 2 – 10 4SH 1½ x 2½ – 6 7SH 1½ x 2½ – 8 5SH 2 x 2½ – 6 8SH 2 x 2½ – 8 6SH 2½ x 3 – 6 F 24 32 54 25 34 25 36 27 NOTE: 1. Pumps shipped in vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 – 16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs. 2. ALL dimensions in inches. 3. Motor dimensions may vary with motor manufacturer. 4. Not for construction purposes. * For use with ANSI class 150 mating flanges. Motor Frame Selections Dimensions Determined by JM Motor Frame JM Frame 143JM 145JM 182JM 184JM 213JM 215JM 254TCZ 256TCZ A AB B D E 6½ 5¼ 6 3½ 2¾ 7 8½ 6 ⁄8 6½ 4½ 3¾ F 2 2½ 2¼ G CREF 1 ⁄8 11¼ 11¼ 9 8 5¼ 4¼ 9½ 6¼ 11¾ 5 11 ⁄32 ⁄16 13½ 7 ⁄8 13 ⁄32 7 3½ 41⁄8 5 65⁄8 7 3 2¾ 9½ 73⁄8 P Motor Wt. H (lbs.) Dia. Max. 95⁄8 ⁄32 15½ ¼ 185⁄8 17 ⁄32 11½ 41 57 77 97 122 155 265 320 Motor Frame 143JM 145JM 182JM 184JM 213JM 215JM 254TCZ 256TCZ Motor Horsepower 3500 RPM 1750 RPM 1Ø 3Ø 1Ø 3Ø ODP TEFC ODP TEFC ODP TEFC ODP TEFC – – – – – – 1 1 2 2 2-3 2 1-1½ 1-1½ 1½-2 1½-2 3 3 5 3 2 2-3 3 3 5 5 7½ 5 3 – 5 5 7½ – 10 7½ 5 – 7½ 7½ 10 – 15 10-15 – – – – – – 20 – – – – – – – 25 20 – – – – GOULDS PUMPS Commercial Water 29 M-Group SSH Close Coupled – Dimensions and Weights (All dimensions in inches and weights in lbs. Do not use for construction purposes.) CPMAX. AB Y DISCHARGE 415⁄16 MAX. PRIME PLUG SUCTION P MAX. D DC MAX.DD G E DRAIN PLUG E H-4 HOLES L F F 3 ⁄8-19 BSF A B Dimensions “L” Determined by Pump and Motor Pump Size Pump CP Max. Suction* Discharge* DC Max. DD X Y Wt. (lbs.) Motor Frame Size 140 180 24SH 1½ x 2 ½-10 25SH 2 x 2½-10 22SH 2½ x 3-8 27SH 2½ x 3-10 23SH 3 x 4-8 1½ 2½ 34½ 2 3 36 2½ 67⁄8 65⁄8 61⁄8 57⁄8 67⁄8 4 28SH 3 x 4-10 * For use with ANSI class 150 mating flanges. 3 37 75⁄8 145JM 182JM 184JM 213JM 215JM 254JM 256JM 284JM 286JM 324JM 326JM 364TCZ 365TCZ A AB Max. B D E F 6½ 5¼ 6 3½ 2¾ 8½ 7 5 ⁄8 6½ 4½ 3¾ 2½ 2¼ 9½ 73⁄8 8 5¼ 4¼ 11¼ 9 11¾ 6¼ 5 14 17¾ 12¼ 12¼ 13¼ 14 151⁄8 15½ 7 5½ 8 6¼ 9 7 65⁄8 915⁄16 73⁄8 111⁄8 5 280 320 360 10½ — 111⁄8 75 72 — 84 — 98 — 137⁄8 143⁄8 133⁄8 147⁄8 153⁄8 15 — 11½ 121⁄8 86 121⁄8 — 16 Motor Frame Selections G 1 ⁄8 H 11 ⁄32 3 ⁄16 Frame ⁄32 103⁄16 ⁄32 13¼ ¼ 17 ⁄32 15 5 1615⁄16 ⁄16 21 ⁄32 1 364TCZ and 365TCZ frames are built with 326JM shaft extensions. Dimensions may vary with manufacturer. 3500 RPM 73⁄16 8½ 7 3½ 41⁄8 5 4¾ 5½ 5¼ 6 55⁄8 61⁄8 Motor Horsepower P Max. 13 2¾ 12¼ 4 250 NOTES: 1. Pumps shipped in vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 – 16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs., ½ – 13 bolts to 35 ft./lbs. 2. Motor dimensions may vary with motor manufacturer. 3. Not for construction purposes. Dimensions Determined by JM Motor Frame Frame 75 815⁄16 210 19 145JM 182JM 184JM 213JM 215JM 254JM 256JM 284JM 286JM 324JM 326JM 364TCZ 365TCZ ODP – – – 10 15 20 25 30 40 50 60 75 100 3 PH TEFC – – – – 10 15 20 25 30 40 50 60 75, 100 Wt. Max. 1750 RPM ODP – 2 3 5 – – – – – – – – – 1 PH TEFC – 2, 3 – – – – – – – – – – – ODP 2 3 5 7½ 10 15 20 25 – – – – – 3 PH TEFC 2 3 5 7½ 10 15 20 25 – – – – – 57 77 97 141 155 265 320 419 422 562 625 775 905 364TCZ and 365TCZ frames are built with 326JM shaft extensions. GOULDS PUMPS Commercial Water 30 S-Group SSH Frame Mounted – Dimensions and Weights CP DISCHARGE Y Z PRIME PLUG X 3½ SUCTION 5¼ 2¾ 2¾ 1.125 DIA. 1.124 KEYWAY 1⁄8 x ¼, CHAVETERO 1⁄8 x ¼ 7 ⁄16 DIA. – (4) HOLES DC MAX.DD DRAIN PLUG 5 L 7 3 ⁄8" – 19 BSP ¾ ½ 6½ Dimensions and Weights – Bare Pump Only 150 lb. Flange Pump DC Max. CP DD Max. 5 55⁄8 67⁄8 5 55⁄8 5 4¾ 163⁄4 53⁄8 65⁄8 179⁄16 4¾ 169⁄16 53⁄8 4¾ 175⁄16 5¾ Suction* Discharge* 9SH 1x2–6 10SH 1 x 2 – 8 11SH 1 x 2 – 10 4SH 1½ x 2½ – 6 7SH 1½ x 2½ – 8 5SH 2 x 2½ – 6 8SH 2 x 2½ – 8 6SH 2½ x 3 – 6 2 1 1½ 2½ 2 3 2½ 6 L X Y Z 63⁄8 1 3 ⁄8 71⁄8 37⁄8 8¾ 87⁄8 4 7¾ 63⁄8 3¼ 77⁄8 71⁄8 8½ 4 715⁄16 35⁄8 Wt. (lbs.) 56 64 86 57 65 57 68 59 NOTE: 1. Pumps will be shipped with top vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3 ⁄8 –16 bolts to 12 ft./lbs., 7 ⁄16 – 14 bolts to 20 ft./lbs. 2. ALL dimensions in inches. 3. Not for construction purposes. * For use with ANSI class 150 mating flanges. GOULDS PUMPS Commercial Water 31 SSH Frame Mounted – Dimensions and Weights M-Group CP DISCHARGE 415⁄16 Y PRIME PLUG 37⁄8 SUCTION 1.625 DIA. 1.624 KEYWAY 61⁄4 31⁄2 31⁄2 3⁄16X3⁄8 DC MAX. DD 4 HOLES 9⁄16 DIA . L 61⁄2 3/8” – BSP 81⁄2 DRAIN PLUG 81⁄2 1” 1⁄2 Dimensions and Weights – Bare Pump Only Pump Size Pump 24SH 25SH 22SH 27SH 23SH 28SH 1½ x 2½-10 2 x 2½-10 2½ x 3-8 2½ x 3-10 3 x 4-8 3 x 4-10 Suction* Discharge* 2½ 1½ 2 3 2½ 4 3 CP 23 24 DC Max. DD 67⁄8 65⁄8 61⁄8 57⁄8 67⁄8 65⁄8 75⁄8 73⁄8 L 10¼ X 815⁄16 Y 4 915⁄16 11¼ 111⁄8 5 Wt. (lbs.) 125 125 125 134 136 148 * For use with ANSI class 150 mating flanges. NOTES: 1. Pumps will be shipped with top vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, replace and tighten 3 ⁄8 –16 bolts to 12 ft./lbs. 2. Motor dimensions may vary with motor manufacturer. 3. Not for construction purposes. GOULDS PUMPS Commercial Water 32 Specifications Capacities to: 1100 GPM (250 m3/hr) at 3500 RPM 775 GPM (177 m3/hr) at 1750 RPM Heads to: 525 feet THD (158 m) at 3500 RPM 130 feet THD (40 m) at 1750 RPM Maximum working pressures to: 230 PSI (15 bars) Maximum temperatures to: 250°F (121°C) All wetted components of AISI: Type 316L stainless steel material. Rotation: Clockwise when viewed from motor end. Enclosed impeller and replaceable wear ring: for high efficiency and maximum wear life. Motor (close coupled): NEMA standard JM shaft open drip-proof, totally enclosed and explosion-proof enclosures, 60 Hz, 1750 or 3500 RPM. Single phase ODP (115/230 V) 1750 RPM, 1 – 5 HP. Three phase ODP. TEFC/Exp. proof (208 – 230/460 V). 3500 RPM, 2 – 100 HP 1750 RPM, 1 – 25 HP NOTE: Overload protection must be provided. Contactor with overload for single phase or starter with heaters for three phase ordered separately. Motor (frame mounted): NEMA standard T-frame open drip-proof, totally enclosed and explosion-proof (three phase only) enclosures 60 Hz, 1750 or 3500 RPM. Single phase (115/230 V) 1750 RPM, 1 – 5 HP Three phase (208 – 230/460 V) 3500 RPM, 3 – 125 HP 1750 RPM, 1 – 25 HP NOTE: Overload protection must be provided. Contactor with overload for single phase or starter with heaters for three phase ordered separately. Optional: Rigid carbon steel bedplate, sheet metal coupling guard designed to OSHA specifications and T.B. WOODS type “SC” spacer couplings. GOULDS PUMPS Commercial Water 33 Typical Applications HVAC Specifically designed for all traditional cast iron or bronze fitted water and low grade corrosive services. • Water circulation • Booster systems • Liquid transfer • HVAC pump replacements • General service pumping Water truck PCB washer Tubing washer Textile dyes Reverse osmosis Boiler feed GOULDS PUMPS Commercial Water 34 Notes GOULDS PUMPS Commercial Water 35 IT T ITT Corporation. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. © 2006 ITT Corporation Engineered for life Commercial Water
Similar documents
Goulds Pumps
Motor Rating: 3 phase, TEFC, 208 – 230 volt, 0 – 60 HZ, Class F insulation,NEMA design A or B Power Supply: single phase input, 220 – 240 volt, ±10%, 40 – 70 HZ Three Phase Version: 5 HP to 15 HP M...
More information