Puteaux City Council Street Light Stage 2, part 1

Transcription

Puteaux City Council Street Light Stage 2, part 1
GGE Puteaux Trail Document - Stage 2
Puteaux City Council Street Light Trials
Stage 2, part 1 – Installation & Measurement
Avenue de Tilleuls,
Tilleul Puteaux
Version 1
Copyright © 2004-2010 by Green Globe Europe
All rights reserved.
Note: Podium Vision Ltd reserves the right to change the contents of this document without forewarning.
forewarning. Accurate as of time of release. Podium
Vision Ltd does not accept any liability for any errors or changes that maybe accidentally incorporated in this document.
Copyright © 2004-2010 by Green Globe Europe
1
Contents
I.
SUMMARY......................................................................................................... 3
Conclusions............................................................................................................................................................................................. 3
II.
SITE INFORMATION ...................................................................................... 4
III.
MEASUREMENTS ............................................................................................. 8
IV.
ENERGY SAVINGS CALCULATIONS .......................................................... 10
Figures
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
1
2
3
4
5
6
7
8
- Google Map of avenue de Tilleuls ..............................................................................4
- GGE AF10-B50S-150S Street Light Fixture ...............................................................5
- Daylight Photo of Existing HPS Street Light, avenue de Tilleuls ...........................5
- Old HPS Street Lights Removed & On the Ground .................................................. 5
– Existing street lights, avenue de Tilleuls ..................................................................6
- 5000K GGE Induction Light, avenue de Tilleuls .......................................................6
- 3000K GGE Induction Light, avenue de Tilleuls .......................................................6
- Lux Measurement Points ..............................................................................................9
Tables
Table 1 - Lux readings. Avenue Tilleuls. ......................................................................................9
2
Copyright © 2004-2010 by Green Globe Europe
GGE Puteaux Trail Document - Stage 2
I. Summary
This report by Green Globe Europe Ltd (“GGE”) is on streetlight trials for the Mairie de Puteaux
(west
west of Paris next to the commercial centre
cent called La Defense) – stage 2, phase 1.
1 The 1st report
highlighted the successful results of the 1st trial – 2 induction lights in rue Montaigne, Puteaux.
From the initial successful trail, the city council has asked us to submit a proposal to run a bigger
bigg
trial – 3 whole streets. This is the 1st part of this 2nd stage – the installation of 2 x 150W street
lights (not retrofit kits) in rue Tilleuls. The 2nd part will be done in March, 2011 when the retrofit
kits are installed.
This report provides results of the preliminary measurements.
Conclusions
The measurements show that –
For 50% less power (compared to old passive ballast 250W HPS lights)
GGE/AMKO induction street lights provide as much lux on the ground and
provide better light quality.
Copyright © 2004-2010 by Green Globe Europe
3
II.
Site Information
This section describes the general information about avenue de Tilleuls.
Figure 1 - Google Map of avenue de Tilleuls
In the above map you will see avenue de Tilleuls is a short East/West street split in 2. The left
hand side is about 110m long and has the original 2 x 250W HPS lights. The right hand side is
about 95m long and has GGE induction lights – i) 1 x 150W AF10-B50S-150S 3000K street light;
plus ii) 1 x 150W AF10-B50S-150S 5000K street light. This fitting is shown in the following figure:
4
Copyright © 2004-2010 by Green Globe Europe
GGE Puteaux Trail Document - Stage 2
Figure 2 - GGE AF10-B50S-150S
150S Street Light Fixture
The old fixtures are shown below.
Figure 3 - Daylight Photo of Existing HPS Street Light,
Light, avenue de Tilleuls
Figure 4 - Old HPS Street Lights Removed & On the Ground
You can see the quality of the lights and also they are old passive ballasts. The street light fixture,
even with brand new globes has poor fixture efficiency.
It is estimated that the fixture efficiencies are • GGE AF10-B50S-150S - > 77%
• Existing HPS
- max. 50%
Note that we also delivered lights with 2-wire
2
0-10VDC
10VDC interface so that
they can be dimmed. This can be done via LONWorks nodes or the ETDE
Citybox.
The next set of photos show night photos of the existing lights.
Copyright © 2004-2010 by Green Globe Europe
5
Figure 5 – Existing street lights, avenue de Tilleuls
One will notice on the 3 photos of the existing 250W HPS lights that they have poor colour
rendition. In the 1st of these you will see 2 cars below the HPS light are blue & red.
As mentioned, 2 different colours of GGE induction lights were installed – 3000K & 5000K. This
was done so that the city of Puteaux can compare light quality against existing HPS lights and also
against the 3000K & 5000K retrofit kits in rue de Montaigne.
Figure 6 - 5000K GGE Induction Light, avenue de Tilleuls
Figure 7 - 3000K GGE Induction Light, avenue de Tilleuls
One will see the excellent colour quality. One can see the green leaves on the tree, the cream
coloured wall and the blue-grey car in the distance.
Measurements of the street were taken so that future simulations can be done if necessary.
6
Copyright © 2004-2010 by Green Globe Europe
GGE Puteaux Trail Document - Stage 2
Avenue de Tilleuls data is as following
fol
• Road
- 4.35 metres wide. Bitumen surface
• Footpaths
- 0.8m both sides of the road. Bitumen surface. About 10cm higher than
the road
• Lamps
• 7.5 metres off the ground
• 0.5m back from curb
• Average distance between streetlights
- 38 to 40 metres
• Lights
- 150W HPS SON. 1 side of street only – North side.
Copyright © 2004-2010 by Green Globe Europe
7
III. Measurements
This section describes the measurements taken on the 13th December 2010 between 17h30 &
19h00.
3 lights were measured –
3000K 150W GGE Induction light
5000K 150W GGE induction light
250W HPS
6 readings on the ground per light were taken –
Directly underneath the light
Directly out from the light & halfway on the road
Footpath opposite the light
5 metres from the light along the footpath
10 metres from the light along the footpath
Halfway between
etween the lights along the footpath
This is shown in the following drawings.
8
Copyright © 2004-2010 by Green Globe Europe
GGE Puteaux Trail Document - Stage 2
Figure 8 - Lux Measurement Points
The following tables list the measured lux value.
Where
GGE
GGE
HPS
150W
150W
250W
3000K
5000K
Under streetlight
35
40
35
Middle of the street
30
35
35
Footpath opposite street light
22
26
26
5m from street light
13
15
15
10m from street light
4
4
4
1.2
1.2
1
½ way between streetlights
Table 1 - Lux readings. Avenue Tilleuls.
Tilleuls
Copyright © 2004-2010 by Green Globe Europe
9
IV.
Energy Savings Calculations
This section estimates the streetlight savings.
In the 1st stage, ETDE measured the actual power consumption of the existing 250W HPS
streetlights and the induction replacement lights.
ETDE has to take real measurements of the power consumption of the lights.
Even so, we will use the stage 1 readings. They were –
• 250W HPS
- 300W (We are taking a lower estimated in case these lights are better
quality. Avenue Montaigne results were actually 350W)
• 150W induction - 156W (0.7A)
• 48% energy saving
We also know that with passive HPS lights the power factor is very low – approx. 0.8. With
induction lights & electronic ballasts, the power factor is between 0.95 & 0.98.
10
Copyright © 2004-2010 by Green Globe Europe