WITH A HOT DAWG™
Transcription
WITH A HOT DAWG™
TAKE THE CHILL OUT OF YOUR GARAGE OR WORKSPACE WITH A HOT DAWG ™ YEAR-ROUND COMFORT TO WORK, PLAY AND RELAX HOT DAWG POWER-EXHAUSTED, GAS-FIRED UNIT HEATER (MODEL HD) ™ • • • • • • • • • • Hush-puppy quiet operation (see table) Right or left hand controls available on all 30-75 units. Gas, electrical and flue connections can be changed by simply flipping the unit over Uses natural or propane gas Lightweight, easily installs 1” from ceiling with only two angle brackets (included on sizes 30-75, accessory for 100, 125) Full 10-year warranty on heat exchanger Standard power exhaust simplifies side-wall or roof venting with small-diameter vent pipe Permanently-lubricated motor for trouble-free dependability Controls can be either single or two-stage, direct spark ignition, 100% shut-off with continuous retry Low-profile design and neutral color to blend in with decor Also available with a blower (model HDB). Contact Modine for further information HOT DAWG SEPARATED COMBUSTION GAS-FIRED UNIT HEATER (MODEL HDS) ™ Same features as HD, with these added benefits: • • • Draws combustion air from outside the work space, ensuring the unit always has plenty of fresh, clean air to breathe The fresh air supply reduces common concerns about dusty, dirty or humid applications, providing greater durability and reduced maintenance Factory assembled, certified separated combustion saves installation time HOT DAWG H2O LOW PROFILE HOT WATER UNIT HEATER (MODEL HHD) ™ • No external moving parts - twin centrifugal blowers keep all moving parts inside the cabinet • Mounting flexibility (parallel, perpendicular or recessed between joists) allows for horizontal or vertical air delivery • Low-profile design • Available in hammertone beige • Constructed of heavy gauge steel for clean appearance and maximum headroom • Includes two mounting brackets with vibration isolators to reduce noise and vibration • Internal coil can handle water pressures up to 150 PSI and temperatures up to 200° F Hot Dawg H20 Applications Model Sizes Airflow (CFM) GPM 140° F BTU/hr 180° F BTU/hr Application HHD 30 405 405 2 4 20,600 24,200 30,900 36,300 1 to 2 car garage HHD 45 (high speed) 710 710 2 4 29,900 35,100 44,800 52,700 2 to 3 car garage HHD 45 (low speed) 425 425 2 4 20,700 24,400 31,100 36,600 2 to 3 car garage Hot Dawg H2O Mounting Flexibility Horizontal air delivery; perpendicular to joists Vertical air delivery; recessed between joists Horizontal air delivery; parallel to joists A A B B COMBUSTION AIRCOMBUSTION AIR LOUVERS (HD ONLY) LOUVERS (HD ONLY) C (APPROX.) C C (APPROX.) C Dimensions Dimensions (inches)(inches) Performance Performance Model Size Model Size 30 A A 26.8 125 30 45 30 60 45 75 60 100 75 125100 Model Size Model Size 30,000 45,000 60,000 75,000 100,000 125,000 Input 45,000 60,000 75,000 100,000 125,000 Btu/Hr Input Btu/Hr 30,000 24,000 36,000 48,000 60,000 80,000 100,000 24,000 36,000 48,000 60,000 80,000 100,000 Btu/Hr OutputBtu/Hr Output Clearances for Residentially-Certified Unit Heaters 1,1601,980 1,490 Entering (CFM) 720 505 990 7201,1609901,490 505 Entering Airflow (CFM)Airflow 523 749 523 653 749 769 653 565 769 747565 Outlet VelocityOutlet Velocity Temp. Rise 44(°F) 46 44 45 46 48 45 50 48 47 50 Air Temp. RiseAir(°F) 1,980 Mounting Height10 (Max ft.)10 10 12 10 14 12 12 14 16 12 Mounting Height (Max ft.) Heat Throw25 (ft.) 27 25 36 27 38 36 42 38 56 42 Heat Throw (ft.) 1/15 1/151/15 1/121/15 1/12 1/12 1/121/12 1/81/12 Horsepower Horsepower 1,5501,625 1,550 1,6251,550 1,050 RPM 1,550 1,550 1,6251,6251,050 RPM Motor Motor Data P.S.C.S.P.P.S.C.P.S.C. S.P. Type S.P. S.P.P.S.C.S.P.P.S.C. Data S.P. Type Top and Bottom 1” Access Side 1” 2.4 2.4 1.2 2.4 1.2 1.2 2.7 1.2 2.5 3.7 2.5 2.5 4.7 2.5 Amps 2.4 Amps Unit Total Amps 3.7 Unit Total Amps Rear F 18” 16.5 7.25 18.5 1” 7.6 Gas Connection Gas Connection 1/2 I I 34.5 1,550 4.2 H H 1”/18” 4”/6” 14.0 24.0 8.4 1/2 34.5 43.0 25 31.0 43.0 31.0 3.87 10.73 3 4 4 10 14 14 60 85 80 4 44 4 14 18.0 85 125 18.0 ™ •U nits are available in propane or natural gas • Sizes: HD30, HD45, HD60 and HD75 • Available in satin black or standard green • Perfect for single to four-plus car garages • Available with standard power vent only (Not available with stainless steel exchanger or separated combustion) 125 25.10 26.20 Recommended Clearance ToRecommended Unit Side Clearance To Service Clearance Service Clearance CombustibleCombustible Materials Materials Unit Side Typical Application1" 33.50 35.00 Top and Bottom Top and Bottom Access SideAccess Side 1" 1" 1" Side 1" Non-Access Non-Access Side Rear Rear 18" Vent Connector 4" Vent Connector 1" 1 to 1-1/2 Car Garage 45,000 18" 4" 2 to 2-1/2 Car Garage Control Code No. Control Description Control Description 60,000 Direct Spark 100% withRetry Continuous Retry 11 Single-Stage,Single-Stage, Direct Spark Ignition, 100%Ignition, Shut-Off withShut-Off Continuous - Utilizes acombination single-stagegas combination gas controlcontrol. with ignition control. control with ignition - Utilizes a single-stage is litspark with aigniter directon spark igniter on call for heat. 21 Gas is lit with aGas direct call for heat. HD/HDS 75, 100, 125 22.5 18.4 HOT DAWG SPECIAL EDITION BLACK UNITS Clearances Clearances 31.50 23.10 30,000 29.50 33.50 27.50 35.00 21.10 19.10 23.10 17.10 25.10 19.10 26.20 21.10 27.50 21.50 29.50 23.50 31.50 25.50 25.50 ControlControl Options HD/HDSOptions 45 HD/HDS 60 4 Fan DiameterFan Diameter10 10 10 14 Approx. Shipping Approx. Shipping Weight (lbs.) Weight 55 (lbs.)60 55 80 Btu/Hr Input (ACCESSORY) (ACCESSORY) HD/HDS 30 3 3" for4"Model HD, HDS 4" for Model HDS * 3" for Model* HD, for Model SIZES 100/125 13.50 21.50 9.50 11.50 SIZES 100/125 23.50 7.10 9.10 17.10 5.10 5.10 .00 7.10 1.10 9.10 3.10 3.10 .00 1.10 5.50 .00 7.50 1.50 9.50 3.50 11.50 5.50 13.50 7.50 3.50 .00 1.50 Model 22.0 14.9 22.5 15.9 18.4 10.75 14.0 7.25 10.75 10.75 18.5 18.5 18.518.5 18.518.518.5 24.0 7.835 8.4 7.835 7.6 7.67.835 7.67.835 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 Combustion Air Inlet Connector Combustion Air Inlet Connector 3 (in.) 13 Size only) (Model HDS only) Size (Model HDS (in.) 1. For high-efficiency unit only (Model PTC) Hot Dawg Applications 35.5 20.5 18” 4”/6” 1 SIZES 30-75 100/125 18.0 20.5 16.5 22.0 J J 22 22 22 25 22 25 25 1 only) 2.74 2.743.15 2.743.153.15 3.87 3.15 K (HDS only)K (HDS 2.74 only) 3.19 3.195.55 3.195.555.55 10.73 5.55 L (HDS only)L (HDS 3.19 3 3 3/4* 3/4* Vent Connector Size (in.) 3 3 3/4* 3/4* 4 Vent Connector Size (in.) 1” - angle,brackets mounting areaccommodate slotted to accommodate joists 1” - angle, mounting arebrackets slotted to joists oncenterlines. 16” or 24” centerlines. on 16” or 24” SIZES 30-75 45 75 60 100/125 75 26.8 35.5 18”34.534.534.5 34.534.534.5 P.S.C. 2.2 G G 1/8 1” Mounting Mounting Vent Connector E 56 45 30 60 26.8 26.826.8 26.826.826.8 12.2 12.218.0 12.218.018.0 16.5 16.516.5 16.516.516.5 12.2 D 14.914.9 14.914.914.9 Recommended 14.9 14.9Service E 10.1 10.1 10.115.9 10.115.915.9 Clearance F 7.25 7.25 10.75 D 16 2.2 2.7 4.2 4.7 Non-Access Side 3.7 3.7 C C Clearance To Combustible 747 Materials 47 Unit Side B B Control Service Service Thermostat Thermostat Type of 18" 18" 4" 1" 4" Type of Model Gas Size Model Size 115V 24V 24V natural natural 30-125 30-125 21 115V 24V propane propane 30-125 30-125 12 115V 115V 24V 24V natural natural 75-125 115V 24V Large Garage Two-Stage, Spark Ignition, 100% with Continuous Retry12 Two-Stage, Direct SparkDirect Ignition, 100% Shut-Off withShut-Off Continuous Retry - Utilizescombination a two-stage gas combination gasbuilt-in controlignition with built-in ignition control. - Utilizes a two-stage control with control. Firing and rate 50% is 100% and 50%input. of fullGas rated input. is lit spark with a direct spark Firing rate is 100% of full rated is lit withGas a direct 22 on call for heat. igniter on calligniter for heat. 1" 18" 1" 11 115V No. Voltage Voltage Gas 3 toCode 3-1/2 CarVoltage Garage Voltage 75,000-125,000 1" 18" *Sizing data for sample only. Consult a qualified installer for the actual115V for your 22requirements 115V 24V building. propane 24V propane 75-125 75-125 75-125 CUSTOMIZE YOUR HOT DAWG WITH EASY-TO-INSTALL TRIM KITS ™ Choose from three new trim kits. They look great with our standard green units too. Performance Data - Model HD/HDS Model Size 30 45 60 75 100 125 Btu/Hr Input1 30,000 45,000 60,000 75,000 100,000 125,000 Btu/Hr Output1 24,000 36,000 48,000 60,000 80,000 100,000 Entering Airflow (CFM)2 505 720 990 1,160 1,490 1,980 Outlet Velocity 2 523 749 653 769 565 747 Air Temp. Rise (ºF) 44 46 45 48 50 47 Mounting Height (Max ft.) 2 10 10 12 14 12 16 Heat Throw (ft.) 25 27 36 38 42 56 Huntin’ Dawg Model HD/HDS Sound Pressure Level (dBA)1 Model Size Modine Competitor2 5 ft. 5 ft. 30 53 59 45 57 59 60 59 59 75 58 69 Carbon Fiber 1. Measured at distance from unit shown. 2. Competitor published data. Dimensions (inches) - Model HD/HDS Model Size 30 45 60 75 A 26.8 26.8 26.8 26.8 100/125 35.5 B 12.2 12.2 18.0 18.0 20.5 C 22 22 25 25 31.0 Gas Connection 1/2 1/2 1/2 1/2 1/2 Vent Connector Size (in.) 3 3 3/4* 3/4* 4 Approx. Shipping Weight (lbs.) 55 60 80 85 125 * 3” for Model HD, 4” for Model HDS Diamond Dawg CALCULATE YOUR COST AND ENERGY SAVINGS WITH MODINE’S EFFINITY MOBILE APP • Ideal for contractors and engineers responsible for specifying HVAC equipment for projects of any size • By entering simple jobsite data in the intuitive calculator, users can compare products with differing efficiencies, determine the annual cost savings, return on investment and environmental advantages • The results can be saved, emailed and printed with a simple click DOWNLOAD OUR SAVINGS CALCULATOR APP: ™ EFFINITY CONDENSING UNIT HEATER (MODEL PTC) • Up to 97% efficient, all units a minimum of 93% efficient. • The most efficient gas-fired, condensing unit heater in North America • Features Modine’s high-grade stainless steel Conservicore® technology secondary heat exchanger • All sizes are separated combustion • A minimum 15% decrease in C02 versus other gas-fired heaters and minimum 17% gas savings (up to 40%) • A smart investment and respectable ROI with valuable state utility rebates available Performance Data - Model PTC Model size 55 Btu/Hr Input1 55,000 65,000 85,000 110,000 Btu/Hr Output1 51,150 60,450 79,050 102,300 Condensate Production (Gal./Hr.) 0.3 0.4 0.5 0.7 Entering Airflow (CFM) @ 70°F 1,097 1,141 1,650 1,750 Outlet Velocity (FPM)2 618 650 619 668 43 49 44 54 Max. Mounting Height (Ft.) 12 12 13 13 Heat Throw (Ft.) @ Max. Mtg Ht 43 43 48 46 2 Air Temp. Rise (°F) 2 Modine Manufacturing Company 1500 DeKoven Avenue Racine, Wisconsin 53403-2552 1.800.828.HEAT www.ModineHVAC.com 65 85 110 1. Ratings shown are for elevations up to 2,000 ft. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet about sea level. (In Canada see rating plate.) Reduction of ratings requires use of high altitude kit. 2. Data taken at 65ºF ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit, and without deflector hoods. Follow us on Twitter @ModineHVAC See us on YouTube www.youtube.com/ModineHVAC ©2015 Modine Manufacturing Co. 6-114.9
Similar documents
WITH A HOT DAWG.
GAS-FIRED UNIT HEATER (MODEL HDS) Same features as HD, with these added benefits:
More informationLow Profile Hot Water Unit Heaters
➃ Allowable water temperature range is 100°F to 200°F. Allowable indoor air temperature range is 40°F to 100°F. If temperatures below freezing are expected, provisions should be made to either dra...
More information